Sample records for ufp number concentrations

  1. Outdoor and indoor UFP in primary schools across Barcelona.

    PubMed

    Reche, C; Viana, M; Rivas, I; Bouso, L; Àlvarez-Pedrerol, M; Alastuey, A; Sunyer, J; Querol, X

    2014-09-15

    Indoor and outdoor measurements of real-time ultrafine particles (UFP; N10-700 in this study) number concentration and average diameter were collected twice at 39 primary schools located in Barcelona (Spain), with classrooms naturally ventilated under warm weather conditions. Simultaneous outdoor N concentration measurements at schools under different traffic exposures showed the important role of this source, with higher levels by 40% on average at schools near heavy traffic, highlighting thus the increased exposure of children due to urban planning decisions. A well-defined spatial pattern of outdoor UFP levels was observed. Midday increases in outdoor N levels mainly attributed to nucleation processes have been recorded both at high and low temperatures in several of the outdoor school sites (increasing levels by 15%-70%). The variation of these increases also followed a characteristic spatial pattern, pointing at schools' location as a key variable in terms of UFP load owing to the important contribution of traffic emissions. Indoor N concentrations were to some extent explained by outdoor N concentrations during school hours, together with average temperatures, related with natural ventilation. Outdoor midday increases were generally mimicked by indoor N concentrations, especially under warm temperatures. At specific cases, indoor concentrations during midday were 30%-40% higher than outdoor. The time scale of these observations evidenced the possible role of: a) secondary particle formation enhanced by indoor precursors or conditions, maybe related with surface chemistry reactions mediated by O3, and/or b) UFP from cooking activities. Significant indoor N increases were detected after school hours, probably associated with cleaning activities, resulting in indoor N concentrations up to 3 times higher than those in outdoor. A wide variability of indoor/outdoor ratios of N concentrations and mean UFP sizes was detected among schools and measurement periods

  2. Exposure Assessment for Atmospheric Ultrafine Particles (UFPs) and Implications in Epidemiologic Research

    PubMed Central

    Sioutas, Constantinos; Delfino, Ralph J.; Singh, Manisha

    2005-01-01

    Epidemiologic research has shown increases in adverse cardiovascular and respiratory outcomes in relation to mass concentrations of particulate matter (PM) ≤2.5 or ≤10 μm in diameter (PM2.5, PM10, respectively). In a companion article [Delfino RJ, Sioutas C, Malik S. 2005. Environ Health Perspect 113(8):934–946]), we discuss epidemiologic evidence pointing to underlying components linked to fossil fuel combustion. The causal components driving the PM associations remain to be identified, but emerging evidence on particle size and chemistry has led to some clues. There is sufficient reason to believe that ultrafine particles < 0.1 μm (UFPs) are important because when compared with larger particles, they have order of magnitudes higher particle number concentration and surface area, and larger concentrations of adsorbed or condensed toxic air pollutants (oxidant gases, organic compounds, transition metals) per unit mass. This is supported by evidence of significantly higher in vitro redox activity by UFPs than by larger PM. Although epidemiologic research is needed, exposure assessment issues for UFPs are complex and need to be considered before undertaking investigations of UFP health effects. These issues include high spatial variability, indoor sources, variable infiltration of UFPs from a variety of outside sources, and meteorologic factors leading to high seasonal variability in concentration and composition, including volatility. To address these issues, investigators need to develop as well as validate the analytic technologies required to characterize the physical/chemical nature of UFPs in various environments. In the present review, we provide a detailed discussion of key characteristics of UFPs, their sources and formation mechanisms, and methodologic approaches to assessing population exposures. PMID:16079062

  3. Spatio-temporal variation of urban ultrafine particle number concentrations

    NASA Astrophysics Data System (ADS)

    Ragettli, Martina S.; Ducret-Stich, Regina E.; Foraster, Maria; Morelli, Xavier; Aguilera, Inmaculada; Basagaña, Xavier; Corradi, Elisabetta; Ineichen, Alex; Tsai, Ming-Yi; Probst-Hensch, Nicole; Rivera, Marcela; Slama, Rémy; Künzli, Nino; Phuleria, Harish C.

    2014-10-01

    Methods are needed to characterize short-term exposure to ultrafine particle number concentrations (UFP) for epidemiological studies on the health effects of traffic-related UFP. Our aims were to assess season-specific spatial variation of short-term (20-min) UFP within the city of Basel, Switzerland, and to develop hybrid models for predicting short-term median and mean UFP levels on sidewalks. We collected measurements of UFP for periods of 20 min (MiniDiSC particle counter) and determined traffic volume along sidewalks at 60 locations across the city, during non-rush hours in three seasons. For each monitoring location, detailed spatial characteristics were locally recorded and potential predictor variables were derived from geographic information systems (GIS). We built multivariate regression models to predict local UFP, using concurrent UFP levels measured at a suburban background station, and combinations of meteorological, temporal, GIS and observed site characteristic variables. For a subset of sites, we assessed the relationship between UFP measured on the sidewalk and at the nearby residence (i.e., home outdoor exposure on e.g. balconies). The average median 20-min UFP levels at street and urban background sites were 14,700 ± 9100 particles cm-3 and 9900 ± 8600 particles cm-3, respectively, with the highest levels occurring in winter and the lowest in summer. The most important predictor for all models was the suburban background UFP concentration, explaining 50% and 38% of the variability of the median and mean, respectively. While the models with GIS-derived variables (R2 = 0.61) or observed site characteristics (R2 = 0.63) predicted median UFP levels equally well, mean UFP predictions using only site characteristic variables (R2 = 0.62) showed a better fit than models using only GIS variables (R2 = 0.55). The best model performance was obtained by using a combination of GIS-derived variables and locally observed site characteristics (median: R2 = 0

  4. [Ultrafine particle number concentration and size distribution of vehicle exhaust ultrafine particles].

    PubMed

    Lu, Ye-qiang; Chen, Qiu-fang; Sun, Zai; Cai, Zhi-liang; Yang, Wen-jun

    2014-09-01

    Ultrafine particle (UFP) number concentrations obtained from three different vehicles were measured using fast mobility particle sizer (FMPS) and automobile exhaust gas analyzer. UFP number concentration and size distribution were studied at different idle driving speeds. The results showed that at a low idle speed of 800 rmin-1 , the emission particle number concentration was the lowest and showed a increasing trend with the increase of idle speed. The majority of exhaust particles were in Nuclear mode and Aitken mode. The peak sizes were dominated by 10 nm and 50 nm. Particle number concentration showed a significantly sharp increase during the vehicle acceleration process, and was then kept stable when the speed was stable. In the range of 0. 4 m axial distance from the end of the exhaust pipe, the particle number concentration decayed rapidly after dilution, but it was not obvious in the range of 0. 4-1 m. The number concentration was larger than the background concentration. Concentration of exhaust emissions such as CO, HC and NO showed a reducing trend with the increase of idle speed,which was in contrast to the emission trend of particle number concentration.

  5. Commuter exposure to PM2.5, BC, and UFP in six common transport microenvironments in Sacramento, California

    NASA Astrophysics Data System (ADS)

    Ham, Walter; Vijayan, Abhilash; Schulte, Nico; Herner, Jorn D.

    2017-10-01

    This study was designed to estimate and compare the air pollution exposures experienced by commuters in six common transportation modes utilized by California residents, and to evaluate the impact of practical exposure mitigation strategies in reducing commute exposures. We measured concentrations of fine particle matter (PM2.5), black carbon (BC), and ultrafine particles (UFP) for 161 commutes between April 2014 and November 2015 in Sacramento, CA. We collected measurements for six modes including single occupancy vehicles, high occupancy vehicles (multiple occupants), buses, light rail, train, and bicycling. The largest average concentrations for most pollutants were measured during train commutes and the lowest average concentrations were observed during light-rail commutes. Mitigation options were explored for personal vehicles, bicycling, and train commute modes. We found that ventilation settings of personal vehicles can reduce in-vehicle PM2.5, BC, and UFP concentrations by up to 75%. Similarly, bicycle route choice can reduce exposures by 15-75% with the lowest concentrations observed during commutes on dedicated bicycle paths away from traffic sources. Train commuters experienced UFP concentrations an order of magnitude greater when the locomotive engine was pulling the rail cars versus pushing the rail cars. We found that UFP concentrations during bus, bicycling, and train commutes were 1.6-5.3 times greater than personal vehicle commutes, while light rail commutes had 30% lower UFP concentrations than personal vehicle commutes. The largest exposure per mile occurred during bicycle commutes with PM2.5, BC, and UFP exposures of 1.312 μg/mile, 0.097 μg/mile, and 3.0 × 109 particles/mile, respectively. Train commutes experienced the largest exposure per mile of all of the combustion-derived transportation commute modes. BC accounted for 5-20% of total PM mass across all commute modes with an average fraction of ∼7% of PM2.5.

  6. Insights on wood combustion generated proinflammatory ultrafine particles (UFP).

    PubMed

    Corsini, Emanuela; Ozgen, Senem; Papale, Angela; Galbiati, Valentina; Lonati, Giovanni; Fermo, Paola; Corbella, Lorenza; Valli, Gianluigi; Bernardoni, Vera; Dell'Acqua, Manuela; Becagli, Silvia; Caruso, Donatella; Vecchi, Roberta; Galli, Corrado L; Marinovich, Marina

    2017-01-15

    This study aimed to collect, characterize ultrafine particles (UFP) generated from the combustion of wood pellets and logs (softwood and hardwood) and to evaluate their pro-inflammatory effects in THP-1 and A549 cells. Both cell lines responded to UFP producing interleukin-8 (IL-8), with wood log UFP being more active compared to pellet UFP. With the exception of higher effect observed with beech wood log UFP in THP-1, the ability of soft or hard woods to induce IL-8 release was similar. In addition, on weight mass, IL-8 release was similar or lower compared to diesel exhaust particles (DEP), arguing against higher biological activity of smaller size particles. UFP-induced IL-8 could be reduced by SB203580, indicating a role of p38MAPK activation in IL-8 production. The higher activity of beech wood log UFP in THP-1 was not due to higher uptake or endotoxin contamination. Qualitatively different protein adsorption profiles were observed, with less proteins bound to beech UFP compared to conifer UFP or DEP, which may provide higher intracellular availability of bioactive components, i.e. levoglucosan and galactosan, toward which THP-1 were more responsive compared to A549 cells. These results contribute to our understanding of particles emitted by domestic appliances and their biological effects. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Spatial-temporal variations of particle number concentrations between a busy street and the urban background

    NASA Astrophysics Data System (ADS)

    Dos Santos-Juusela, Vanessa; Petäjä, Tuukka; Kousa, Anu; Hämeri, Kaarle

    2013-11-01

    To estimate spatial-temporal variations of ultrafine particles (UFP) in Helsinki, we measured particle total number concentrations (PNC) continuously in a busy street and an urban background site for six months, using condensation particle counters (CPC). We also evaluated the effects of temperature, wind speed and wind direction on PNC, as well as the correlation between PNC and PM2.5, PM10 and black carbon (BC) at the street. We found that on weekdays, hourly median PNC were highly correlated with BC (r = 0.88), moderately correlated with PM2.5 (r = 0.59) and weakly correlated with PM10 (r = 0.22). Number concentrations at the street were inversely proportional to temperature and wind speed, and highly dependent on wind direction. The highest PNC occurred during northeastern winds while the lowest occurred during southwestern winds. As these wind directions are nearly perpendicular to the street axis, the formation of wind vortices may have influenced the dispersion of UFP in the site. Although the temporal correlation for PNC was moderately high between the sites (r = 0.71), the median concentration at the street was 3 times higher than the urban background levels. The results indicate that people living or passing by the busy street are exposed to UFP concentrations well above the urban background levels. Thus, the study suggests that urban microenvironments should be considered in epidemiological studies. In addition the results emphasize that regulations based solely on PM2.5 and PM10 concentrations may be insufficient for preventing the adverse health effects of airborne particles.

  8. The Effects of Vegetation Barriers on Near-road Ultrafine Particle Number and Carbon Monoxide Concentrations

    EPA Science Inventory

    Numerous studies have shown that people living in near-roadway communities (within 100 m of the road) are exposed to high ultrafine particle (UFP) number concentrations, which may be associated with adverse health effects. Vegetation barriers have been shown to affect pollutant t...

  9. PEP Integrated Test D Run Report Caustic and Oxidative Leaching in UFP-VSL-T02A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevigny, Gary J.; Bredt, Ofelia P.; Burns, Carolyn A.

    2009-12-11

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes" of the External Flowsheet Review Team (EFRT) issue response plan. The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. Themore » PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario (Test B and D) has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario (Test A) has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP VSL-00001A and B in the WTP PTF). In Test D, 19M sodium hydroxide (NaOH, caustic) was added to the waste slurry in the UFP VSL T02 vessel after the solids were concentrated to ~20% undissolved solids. The NaOH was added to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by heating to 85°C using direct injection of steam to accelerate the leach process. The main difference of Test D compared to Test B is that the leach temperature is 85°C for 24 hrs as compared to 100°C for 12 hours. The other difference is the Test D simulant had Cr in

  10. Particle number concentrations near the Rome-Ciampino city airport

    NASA Astrophysics Data System (ADS)

    Stafoggia, M.; Cattani, G.; Forastiere, F.; Di Menno di Bucchianico, A.; Gaeta, A.; Ancona, C.

    2016-12-01

    Human exposure to ultrafine particles (UFP) has been postulated to be associated with adverse health effects, and there is interest regarding possible measures to reduce primary emissions. One important source of UFP are airport activities, with aircraft take-offs being the most relevant one. We implemented two measurement campaigns of total particle number concentrations (PNC), a proxy for UFP, near a medium-size airport in central Italy. One-minute PNC averages were collected on June 2011 and January 2012 concurrently with 30-min average meteorological data on temperature and wind speed/direction. Data on minute-specific take-offs and landings were obtained by the airport authorities. We applied statistical regression models to relate PNC data to the presence of aircraft activities while adjusting for time trends and meteorology, and estimated the increases in PNC ±15 min before and after take-offs and landings. We repeated the analyses considering prevalent wind direction and by size of the aircraft. We estimated PNC increases of 5400 particles/cm3/minute during the 15 min before and after take-offs, with a peak of 19,000 particles/cm3/minute within 5 min after take-offs. Corresponding figures for landings were 1300 and 1000 particles, respectively. The highest PNC estimates were obtained when the prevailing wind came from the runway direction, and led to estimated PNC increases of 60,000 particles/cm3/minute within 5 min after take-offs. No main differences were noted from the exhaust of different types of aircrafts. The area surrounding Ciampino airport is densely inhabited, raising concerns about the potential adverse effects of long-term and short-term exposure to airport-borne UFP. A close monitoring of airport activities and emissions is mandatory to reduce the public health impact of the airport on the nearby population.

  11. Estimate of main local sources to ambient ultrafine particle number concentrations in an urban area

    NASA Astrophysics Data System (ADS)

    Rahman, Md Mahmudur; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia

    2017-09-01

    Quantifying and apportioning the contribution of a range of sources to ultrafine particles (UFPs, D < 100 nm) is a challenge due to the complex nature of the urban environments. Although vehicular emissions have long been considered one of the major sources of ultrafine particles in urban areas, the contribution of other major urban sources is not yet fully understood. This paper aims to determine and quantify the contribution of local ground traffic, nucleated particle (NP) formation and distant non-traffic (e.g. airport, oil refineries, and seaport) sources to the total ambient particle number concentration (PNC) in a busy, inner-city area in Brisbane, Australia using Bayesian statistical modelling and other exploratory tools. The Bayesian model was trained on the PNC data on days where NP formations were known to have not occurred, hourly traffic counts, solar radiation data, and smooth daily trend. The model was applied to apportion and quantify the contribution of NP formations and local traffic and non-traffic sources to UFPs. The data analysis incorporated long-term measured time-series of total PNC (D ≥ 6 nm), particle number size distributions (PSD, D = 8 to 400 nm), PM2.5, PM10, NOx, CO, meteorological parameters and traffic counts at a stationary monitoring site. The developed Bayesian model showed reliable predictive performances in quantifying the contribution of NP formation events to UFPs (up to 4 × 104 particles cm- 3), with a significant day to day variability. The model identified potential NP formation and no-formations days based on PNC data and quantified the sources contribution to UFPs. Exploratory statistical analyses show that total mean PNC during the middle of the day was up to 32% higher than during peak morning and evening traffic periods, which were associated with NP formation events. The majority of UFPs measured during the peak traffic and NP formation periods were between 30-100 nm and smaller than 30 nm, respectively. To date

  12. Determinants of spikes in ultrafine particle concentration whilst commuting by bus

    NASA Astrophysics Data System (ADS)

    Lim, Shanon; Dirks, Kim N.; Salmond, Jennifer A.; Xie, Shanju

    2015-07-01

    This paper examines concentration of ultrafine particles (UFPs) based on data collected using high-resolution UFP monitors whilst travelling by bus during rush hour along three different urban routes in Auckland, New Zealand. The factors influencing in-bus UFP concentration were assessed using a combination of spatial, statistical and GIS analysis techniques to determine both spatial and temporal variability. Results from 68 bus trips showed that concentrations varied more within a route than between on a given day, despite differences in urban morphology, land use and traffic densities between routes. A number of trips were characterised by periods of very rapid increases in UFPs (concentration 'spikes'), followed by slow declines. Trips which recorded at least one spike (an increase of greater than 10,000 pt/cm3) resulted in significantly higher mean concentrations. Spikes in UFPs were significantly more likely to occur when travelling at low speeds and when passengers were alighting and boarding at bus stops close to traffic light intersections.

  13. Outdoor ultrafine particle concentrations in front of fast food restaurants.

    PubMed

    Vert, Cristina; Meliefste, Kees; Hoek, Gerard

    2016-01-01

    Ultrafine particles (UFPs) have been associated with negative effects on human health. Emissions from motor vehicles are the principal source of UFPs in urban air. A study in Vancouver suggested that UFP concentrations were related to density of fast food restaurants near the monitoring sites. A previous monitoring campaign could not separate the contribution of restaurants from road traffic. The main goal of this study has been the quantification of fast food restaurants' contribution to outdoor UFP concentrations. A portable particle number counter (DiscMini) has been used to carry out mobile monitoring in a largely pedestrianized area in the city center of Utrecht. A fixed route passing 17 fast food restaurants was followed on 8 days. UFP concentrations in front of the restaurants were 1.61 times higher than in a nearby square without any local sources used as control area and 1.22 times higher compared with all measurements conducted in between the restaurants. Adjustment for other sources such as passing mopeds, smokers or candles did not explain the increase. In conclusion, fast food restaurants result in significant increases in outdoor UFP concentrations in front of the restaurant.

  14. Pharmacological characterization of the bifunctional opioid ligand H-Dmt-Tic-Gly-NH-Bzl (UFP-505).

    PubMed

    Dietis, N; McDonald, J; Molinari, S; Calo, G; Guerrini, R; Rowbotham, D J; Lambert, D G

    2012-02-01

    While producing good-quality analgesia, µ-opioid (MOP) receptor activation produces a number of side-effects including tolerance. Simultaneous blockade of δ-opioid (DOP) receptors has been shown to reduce tolerance to morphine. Here, we characterize a prototype bifunctional opioid H-Dmt-Tic-Gly-NH-Bzl (UFP-505). We measured receptor binding affinity in Chinese hamster ovary (CHO) cells expressing recombinant human MOP, DOP, k-opioid (KOP), nociceptin/orphanin (NOP) receptors. For activation, we measured the binding of GTPγ(35)S to membranes from CHO(hMOP), CHO(hDOP), rat cerebrocortex, and rat spinal cord. In addition, we assessed 'end organ' responses in the guinea pig ileum and mouse vas deferens. UFP-505 bound to CHO(hMOP) and CHO(hDOP) with (binding affinity) pK(i) values of 7.79 and 9.82, respectively. There was a weak interaction at KOP and NOP (pK(i) 6.29 and 5.86). At CHO(hMOP), UFP-505 stimulated GTPγ(35)S binding with potency (pEC(50)) of 6.37 and in CHO(hDOP) reversed the effects of a DOP agonist with affinity (pK(b)) of 9.81 (in agreement with pK(i) at DOP). UFP-505 also stimulated GTPγ(35)S binding in rat cerebrocortex and spinal cord with pEC(50) values of 6.11-6.53. In the guinea pig ileum (MOP-rich preparation), UFP-505 inhibited contractility with pEC(50) of 7.50 and in the vas deferens (DOP-rich preparation) reversed the effects of a DOP agonist with an affinity (pA(2)) of 9.15. We have shown in a range of preparations and assays that UFP-505 behaves as a potent MOP agonist and DOP antagonist; a MOP/DOP bifunctional opioid. Further studies in dual expression systems and whole animals with this prototype are warranted.

  15. Observation of Elevated Air Pollutant Concentrations in a Residential Neighborhood of Los Angeles California Using a Mobile Platform

    PubMed Central

    Hu, Shishan; Fruin, Scott; Kozawa, Kathleen; Mara, Steve; Winer, Arthur M.

    2013-01-01

    We observed elevated air pollutant concentrations, especially of ultrafine particles (UFP), black carbon (BC) and NO, across the residential neighborhood of the Boyle Heights Community (BH) of Los Angeles, California. Using an electric vehicle mobile platform equipped with fast response instruments, real-time air pollutant concentrations were measured in BH in spring and summer of 2008. Pollutant concentrations varied significantly in the two seasons, on different days, and by time of day, with an overall average UFP concentration in the residential areas of ~33 000 cm−3. The averaged UFP, BC, and NO concentrations measured on Soto St, a major surface street in BH, were 57 000 cm−3, 5.1 µg m−3, and 67 ppb, respectively. Concentrations of UFP across the residential areas in BH were nearly uniform spatially, in contrast to other areas in the greater metropolitan area of Los Angeles where UFP concentrations exhibit strong gradients downwind of roadways. We attribute this “UFP cloud” to high traffic volumes, including heavy duty diesel trucks on the freeways which surround and traverse BH, and substantial numbers of high-emitting vehicles (HEVs) on the surface streets traversing BH. Additionally, the high density of stop signs and lights and short block lengths, requiring frequent accelerations of vehicles, may contribute. The data also support a role for photochemical production of UFP in the afternoon. UFP concentration peaks (5 s average) of up to 9 million particles cm−3 were also observed immediately behind HEVs when they accelerated from stop lights in the BH neighborhood and areas immediately adjacent. Although encounters with HEV during mornings accounted for only about 6% and 17% of time spent monitoring residential areas and major surface streets, HEV contributed to about 28% and 53% of total ultrafine particles measured on the route, respectively. The observation of elevated pollutant number concentrations across the Boyle Heights community

  16. Measurements of ultrafine particles carrying different number of charges in on- and near-freeway environments

    NASA Astrophysics Data System (ADS)

    Lee, Eon S.; Xu, Bin; Zhu, Yifang

    2012-12-01

    This paper presents measurements of electrical charges on ultrafine particles (UFPs) of different electrical mobility diameters (30, 50, 80, and 100 nm) in on- and near-freeway environments. Using a tandem Differential Mobility Analyzer (DMA) system, we first examined the fraction of UFPs carrying different number of charges on two distinctive freeways: a gasoline-vehicle dominated freeway (I-405) and a heavy-duty diesel truck dominated freeway (I-710). The fractions of UFPs of a given size carrying one or more charges were significantly higher on the freeways than in the background. The background UFPs only carried up to two charges but freeway UFPs could have up to three charges. The total fraction of charged particles was higher on the I-710 than I-405 across the studied electrical mobility diameters. Near the I-405 freeway, we observed a strong decay of charged particles on the downwind side of the freeway. We also found fractional decay of the charged particles was faster than total particle number concentrations, but slower than total ion concentrations downwind from the freeway I-405. Among charged particles, the highest decay rate was observed for particles carrying three charges. Near the I-710 freeway, we found strong net positive charges on nucleation mode particles, suggesting that UFPs were not at steady-state charge equilibrium near freeways.

  17. Ultrafine particle concentrations in and around idling school buses

    NASA Astrophysics Data System (ADS)

    Zhang, Qunfang; Fischer, Heidi J.; Weiss, Robert E.; Zhu, Yifang

    2013-04-01

    Unnecessary school bus idling increases children's exposure to diesel exhaust, but to what extent children are exposed to ultrafine particles (UFPs, diameter < 100 nm) in and around idling school buses remains unclear. This study employed nine school buses and simulated five scenarios by varying emissions source, wind direction, and window position. The purpose was to investigate the impact of idling on UFP number concentration and PM2.5 mass concentration inside and near school buses. Near the school buses, total particle number concentration increased sharply from engine off to engine on under all scenarios, by a factor of up to 26. The impact of idling on UFP number concentration inside the school buses depended on wind direction and window position: wind direction was important and statistically significant while the effect of window positions depended on wind direction. Under certain scenarios, idling increased in-cabin total particle number concentrations by a factor of up to 5.8, with the significant increase occurring in the size range of 10-30 nm. No significant change of in-cabin PM2.5 mass concentration was observed due to idling, regardless of wind direction and window position, indicating that PM2.5 is not a good indicator for primary diesel exhaust particle exposure. The deposition rates based on total particle number concentration inside school bus cabins varied between 1.5 and 5.0 h-1 across nine tested buses under natural convection conditions, lower than those of passenger cars but higher than those of indoor environments.

  18. Comparing conventional Descriptive Analysis and Napping®-UFP against physiochemical measurements: a case study using apples.

    PubMed

    Pickup, William; Bremer, Phil; Peng, Mei

    2018-03-01

    The extensive time and cost associated with conventional sensory profiling methods has spurred sensory researchers to develop rapid method alternatives, such as Napping® with Ultra-Flash Profiling (UFP). Napping®-UFP generates sensory maps by requiring untrained panellists to separate samples based on perceived sensory similarities. Evaluations of this method have been restrained to manufactured/formulated food models, and predominantly structured on comparisons against the conventional descriptive method. The present study aims to extend the validation of Napping®-UFP (N = 72) to natural biological products; and to evaluate this method against Descriptive Analysis (DA; N = 8) with physiochemical measurements as an additional evaluative criterion. The results revealed that sample configurations generated by DA and Napping®-UFP were not significantly correlated (RV = 0.425, P = 0.077); however, they were both correlated with the product map generated based on the instrumental measures (P < 0.05). The finding also noted that sample characterisations from DA and Napping®-UFP were driven by different sensory attributes, indicating potential structural differences between these two methods in configuring samples. Overall, these findings lent support for the extended use of Napping®-UFP for evaluations of natural biological products. Although DA was shown to be a better method for establishing sensory-instrumental relationships, Napping®-UFP exhibited strengths in generating informative sample configurations based on holistic perception of products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. Observation of elevated air pollutant concentrations in a residential neighborhood of Los Angeles California using a mobile platform

    NASA Astrophysics Data System (ADS)

    Hu, Shishan; Paulson, Suzanne E.; Fruin, Scott; Kozawa, Kathleen; Mara, Steve; Winer, Arthur M.

    2012-05-01

    We observed elevated air pollutant concentrations, especially of ultrafine particles (UFP), black carbon (BC) and NO, across the residential neighborhood of the Boyle Heights Community (BH) of Los Angeles, California. Using an electric vehicle mobile platform equipped with fast response instruments, real-time air pollutant concentrations were measured in BH in spring and summer of 2008. Pollutant concentrations varied significantly in the two seasons, on different days, and by time of day, with an overall average UFP concentration in the residential areas of ∼33 000 cm-3. The averaged UFP, BC, and NO concentrations measured on Soto St, a major surface street in BH, were 57 000 cm-3, 5.1 μg m-3, and 67 ppb, respectively. Concentrations of UFP across the residential areas in BH were nearly uniform spatially, in contrast to other areas in the greater metropolitan area of Los Angeles where UFP concentrations exhibit strong gradients downwind of roadways. We attribute this “UFP cloud” to high traffic volumes, including heavy duty diesel trucks on the freeways which surround and traverse BH, and substantial numbers of high-emitting vehicles (HEVs) on the surface streets traversing BH. Additionally, the high density of stop signs and lights and short block lengths, requiring frequent accelerations of vehicles, may contribute. The data also support a role for photochemical production of UFP in the afternoon. UFP concentration peaks (5 s average) of up to 9 million particles cm-3 were also observed immediately behind HEVs when they accelerated from stop lights in the BH neighborhood and areas immediately adjacent. Although encounters with HEV during mornings accounted for only about 6% and 17% of time spent monitoring residential areas and major surface streets, HEV contributed to about 28% and 53% of total ultrafine particles measured on the route, respectively. The observation of elevated pollutant concentrations across the Boyle Heights community highlights

  20. Comparisons of traffic-related ultrafine particle number concentrations measured in two urban areas by central, residential, and mobile monitoring

    NASA Astrophysics Data System (ADS)

    Simon, Matthew C.; Hudda, Neelakshi; Naumova, Elena N.; Levy, Jonathan I.; Brugge, Doug; Durant, John L.

    2017-11-01

    Traffic-related ultrafine particles (UFP; <100 nm diameter) are ubiquitous in urban air. While studies have shown that UFP are toxic, epidemiological evidence of health effects, which is needed to inform risk assessment at the population scale, is limited due to challenges of accurately estimating UFP exposures. Epidemiologic studies often use empirical models to estimate UFP exposures; however, the monitoring strategies upon which the models are based have varied between studies. Our study compares particle number concentrations (PNC; a proxy for UFP) measured by three different monitoring approaches (central-site, short-term residential-site, and mobile on-road monitoring) in two study areas in metropolitan Boston (MA, USA). Our objectives were to quantify ambient PNC differences between the three monitoring platforms, compare the temporal patterns and the spatial heterogeneity of PNC between the monitoring platforms, and identify factors that affect correlations across the platforms. We collected >12,000 h of measurements at the central sites, 1000 h of measurements at each of 20 residential sites in the two study areas, and >120 h of mobile measurements over the course of ∼1 year in each study area. Our results show differences between the monitoring strategies: mean 1 min PNC on-roads were higher (64,000 and 32,000 particles/cm3 in Boston and Chelsea, respectively) compared to central-site measurements (23,000 and 19,000 particles/cm3) and both were higher than at residences (14,000 and 15,000 particles/cm3). Temporal correlations and spatial heterogeneity also differed between the platforms. Temporal correlations were generally highest between central and residential sites, and lowest between central-site and on-road measurements. We observed the greatest spatial heterogeneity across monitoring platforms during the morning rush hours (06:00-09:00) and the lowest during the overnight hours (18:00-06:00). Longer averaging times (days and hours vs. minutes

  1. Comparisons of Traffic-Related Ultrafine Particle Number Concentrations Measured in Two Urban Areas by Central, Residential, and Mobile Monitoring.

    PubMed

    Simon, Matthew C; Hudda, Neelakshi; Naumova, Elena N; Levy, Jonathan I; Brugge, Doug; Durant, John L

    2017-11-01

    Traffic-related ultrafine particles (UFP; <100 nanometers diameter) are ubiquitous in urban air. While studies have shown that UFP are toxic, epidemiological evidence of health effects, which is needed to inform risk assessment at the population scale, is limited due to challenges of accurately estimating UFP exposures. Epidemiologic studies often use empirical models to estimate UFP exposures; however, the monitoring strategies upon which the models are based have varied between studies. Our study compares particle number concentrations (PNC; a proxy for UFP) measured by three different monitoring approaches (central-site, short-term residential-site, and mobile on-road monitoring) in two study areas in metropolitan Boston (MA, USA). Our objectives were to quantify ambient PNC differences between the three monitoring platforms, compare the temporal patterns and the spatial heterogeneity of PNC between the monitoring platforms, and identify factors that affect correlations across the platforms. We collected >12,000 hours of measurements at the central sites, 1,000 hours of measurements at each of 20 residential sites in the two study areas, and >120 hours of mobile measurements over the course of ~1 year in each study area. Our results show differences between the monitoring strategies: mean one-minute PNC on-roads were higher (64,000 and 32,000 particles/cm 3 in Boston and Chelsea, respectively) compared to central-site measurements (23,000 and 19,000 particles/cm 3 ) and both were higher than at residences (14,000 and 15,000 particles/cm 3 ). Temporal correlations and spatial heterogeneity also differed between the platforms. Temporal correlations were generally highest between central and residential sites, and lowest between central-site and on-road measurements. We observed the greatest spatial heterogeneity across monitoring platforms during the morning rush hours (06:00-09:00) and the lowest during the overnight hours (18:00-06:00). Longer averaging times

  2. Estimation of ultrafine particle concentrations at near-highway residences using data from local and central monitors

    PubMed Central

    Fuller, Christina H.; Brugge, Doug; Williams, Paige; Mittleman, Murray; Durant, John L.; Spengler, John D.

    2012-01-01

    Ultrafine particles (UFP; aerodynamic diameter < 0.1 micrometers) are a ubiquitous exposure in the urban environment and are elevated near highways. Most epidemiological studies of UFP health effects use central site monitoring data, which may misclassify exposure. Our aims were to: (1) examine the relationship between distant and proximate monitoring sites and their ability to predict hourly UFP concentration measured at residences in an urban community with a major interstate highway and; (2) determine if meteorology and proximity to traffic improve explanatory power. Short-term (1 – 3 weeks) residential monitoring of UFP concentration was conducted at 18 homes. Long-term monitoring was conducted at two near-highway monitoring sites and a central site. We created models of outdoor residential UFP concentration based on concentrations at the near-highway site, at the central site, at both sites together and without fixed sites. UFP concentration at residential sites was more highly correlated with those at a near-highway site than a central site. In regression models of each site alone, a 10% increase in UFP concentration at a near-highway site was associated with a 6% (95% CI: 6%, 7%) increase at residences while a 10% increase in UFP concentration at the central site was associated with a 3% (95% CI: 2%, 3%) increase at residences. A model including both sites showed minimal change in the magnitude of the association between the near-highway site and the residences, but the estimated association with UFP concentration at the central site was substantially attenuated. These associations remained after adjustment for other significant predictors of residential UFP concentration, including distance from highway, wind speed, wind direction, highway traffic volume and precipitation. The use of a central site as an estimate of personal exposure for populations near local emissions of traffic-related air pollutants may result in exposure misclassification. PMID

  3. Estimation of ultrafine particle concentrations at near-highway residences using data from local and central monitors.

    PubMed

    Fuller, Christina H; Brugge, Doug; Williams, Paige; Mittleman, Murray; Durant, John L; Spengler, John D

    2012-09-01

    Ultrafine particles (UFP; aerodynamic diameter < 0.1 micrometers) are a ubiquitous exposure in the urban environment and are elevated near highways. Most epidemiological studies of UFP health effects use central site monitoring data, which may misclassify exposure. Our aims were to: (1) examine the relationship between distant and proximate monitoring sites and their ability to predict hourly UFP concentration measured at residences in an urban community with a major interstate highway and; (2) determine if meteorology and proximity to traffic improve explanatory power. Short-term (1 - 3 weeks) residential monitoring of UFP concentration was conducted at 18 homes. Long-term monitoring was conducted at two near-highway monitoring sites and a central site. We created models of outdoor residential UFP concentration based on concentrations at the near-highway site, at the central site, at both sites together and without fixed sites. UFP concentration at residential sites was more highly correlated with those at a near-highway site than a central site. In regression models of each site alone, a 10% increase in UFP concentration at a near-highway site was associated with a 6% (95% CI: 6%, 7%) increase at residences while a 10% increase in UFP concentration at the central site was associated with a 3% (95% CI: 2%, 3%) increase at residences. A model including both sites showed minimal change in the magnitude of the association between the near-highway site and the residences, but the estimated association with UFP concentration at the central site was substantially attenuated. These associations remained after adjustment for other significant predictors of residential UFP concentration, including distance from highway, wind speed, wind direction, highway traffic volume and precipitation. The use of a central site as an estimate of personal exposure for populations near local emissions of traffic-related air pollutants may result in exposure misclassification.

  4. Ultrafine particles (UFPs) from domestic wood stoves: genotoxicity in human lung carcinoma A549 cells.

    PubMed

    Marabini, Laura; Ozgen, Senem; Turacchi, Silvia; Aminti, Stefania; Arnaboldi, Francesca; Lonati, Giovanni; Fermo, Paola; Corbella, Lorenza; Valli, Gianluigi; Bernardoni, Vera; Dell'Acqua, Manuela; Vecchi, Roberta; Becagli, Silvia; Caruso, Donatella; Corrado, Galli L; Marinovich, Marina

    2017-08-01

    In this paper, results on the potential toxicity of ultrafine particles (UFPs d<100nm) emitted by the combustion of logwood and pellet (hardwood and softwood) are reported. The data were collected during the TOBICUP (TOxicity of BIomass COmbustion generated Ultrafine Particles) project, carried out by a team composed of interdisciplinary research groups. The genotoxic evaluation was performed on A549 cells (human lung carcinomacells) using UFPs whose chemical composition was assessed by a suite of analytical techniques. Comet assay and γ-H2AX evaluation show a significant DNA damage after 24h treatment. The interpretation of the results is based on the correlation among toxicological results, chemical-physical properties of UFPs, and the type and efficiency conditions in residential pellet or logwood stoves. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Linking In-Vehicle Ultrafine Particle Exposures to On-Road Concentrations

    PubMed Central

    Hudda, Neelakshi; Eckel, Sandrah P.; Knibbs, Luke D.; Sioutas, Constantinos; Delfino, Ralph J.; Fruin, Scott A.

    2013-01-01

    For traffic-related pollutants like ultrafine particles (UFP, Dp < 100 nm), a significant fraction of overall exposure occurs within or close to the transit microenvironment. Therefore, understanding exposure to these pollutants in such microenvironments is crucial to accurately assessing overall UFP exposure. The aim of this study was to develop models for predicting in-cabin UFP concentrations if roadway concentrations are known, taking into account vehicle characteristics, ventilation settings, driving conditions and air exchange rates (AER). Particle concentrations and AER were measured in 43 and 73 vehicles, respectively, under various ventilation settings and driving speeds. Multiple linear regression (MLR) and generalized estimating equation (GEE) regression models were used to identify and quantify the factors that determine inside-to-outside (I/O) UFP ratios and AERs across a full range of vehicle types and ages. AER was the most significant determinant of UFP I/O ratios, and was strongly influenced by ventilation setting (recirculation or outside air intake). Inclusion of ventilation fan speed, vehicle age or mileage, and driving speed explained greater than 79% of the variability in measured UFP I/O ratios. PMID:23888122

  6. Ultrafine particle concentrations and exposures in seven residences in northern California.

    PubMed

    Bhangar, S; Mullen, N A; Hering, S V; Kreisberg, N M; Nazaroff, W W

    2011-04-01

    Human exposures to ultrafine particles (UFP) are poorly characterized given the potential associated health risks. Residences are important sites of exposure. To characterize residential exposures to UFP in some circumstances and to investigate governing factors, seven single-family houses in California were studied during 2007-2009. During multiday periods, time-resolved particle number concentrations were monitored indoors and outdoors and information was acquired concerning occupancy, source-related activities, and building operation. On average, occupants were home for 70% of their time. The geometric mean time-average residential exposure concentration for 21 study subjects was 14,500 particles per cm(3) (GSD = 1.8; arithmetic mean ± standard deviation = 17,000 ± 10,300 particles per cm(3)). The average contribution to residential exposures from indoor episodic sources was 150% of the contribution from particles of outdoor origin. Unvented natural-gas pilot lights contributed up to 19% to exposure for the two households where present. Episodic indoor source activities, most notably cooking, caused the highest peak exposures and most of the variation in exposure among houses. Owing to the importance of indoor sources and variations in the infiltration factor, residential exposure to UFP cannot be characterized by ambient measurements alone. Indoor and outdoor sources each contribute to residential ultrafine particle (UFP) concentrations and exposures. Under the conditions investigated, peak exposure concentrations indoors were associated with cooking, using candles, or the use of a furnace. Active particle removal systems can mitigate exposure by reducing the persistence of particles indoors. Eliminating the use of unvented gas pilot lights on cooking appliances could also be beneficial. The study results indicate that characterization of human exposure to UFP, an air pollutant of emerging public health concern, cannot be accomplished without a good

  7. Children exposure to indoor ultrafine particles in urban and rural school environments.

    PubMed

    Cavaleiro Rufo, João; Madureira, Joana; Paciência, Inês; Slezakova, Klara; Pereira, Maria do Carmo; Aguiar, Lívia; Teixeira, João Paulo; Moreira, André; Oliveira Fernandes, Eduardo

    2016-07-01

    Extended exposure to ultrafine particles (UFPs) may lead to consequences in children due to their increased susceptibility when compared to older individuals. Since children spend in average 8 h/day in primary schools, assessing the number concentrations of UFPs in these institutions is important in order to evaluate the health risk for children in primary schools caused by indoor air pollution. Thus, the purpose of this study was to assess and determine the sources of indoor UFP number concentrations in urban and rural Portuguese primary schools. Indoor and outdoor ultrafine particle (UFP) number concentrations were measured in six urban schools (US) and two rural schools (RS) located in the north of Portugal, during the heating season. The mean number concentrations of indoor UFPs were significantly higher in urban schools than in rural ones (10.4 × 10(3) and 5.7 × 10(3) pt/cm(3), respectively). Higher UFP levels were associated with higher squared meters per student, floor levels closer to the ground, chalk boards, furniture or floor covering materials made of wood and windows with double-glazing. Indoor number concentrations of ultrafine-particles were inversely correlated with indoor CO2 levels. In the present work, indoor and outdoor concentrations of UFPs in public primary schools located in urban and rural areas were assessed, and the main sources were identified for each environment. The results not only showed that UFP pollution is present in augmented concentrations in US when compared to RS but also revealed some classroom/school characteristics that influence the concentrations of UFPs in primary schools.

  8. On-road ultrafine particle concentration in the M5 East road tunnel, Sydney, Australia

    NASA Astrophysics Data System (ADS)

    Knibbs, Luke D.; de Dear, Richard J.; Morawska, Lidia; Mengersen, Kerrie L.

    The human health effects following exposure to ultrafine (<100 nm) particles (UFPs) produced by fuel combustion, while not completely understood, are generally regarded as detrimental. Road tunnels have emerged as locations where maximum exposure to these particles may occur for the vehicle occupants using them. This study aimed to quantify and investigate the determinants of UFP concentrations in the 4 km twin-bore (eastbound and westbound) M5 East tunnel in Sydney, Australia. Sampling was undertaken using a condensation particle counter (CPC) mounted in a vehicle traversing both tunnel bores at various times of day from May through July, 2006. Supplementary measurements were conducted in February, 2008. Over three hundred transects of the tunnel were performed, and these were distributed evenly between the bores. Additional comparative measurements were conducted on a mixed route comprising major roads and shorter tunnels, all within Sydney. Individual trip average UFP concentrations in the M5 East tunnel bores ranged from 5.53 × 10 4 p cm -3 to 5.95 × 10 6 p cm -3. Data were sorted by hour of capture, and hourly median trip average (HMA) UFP concentrations ranged from 7.81 × 10 4 p cm -3 to 1.73 × 10 6 p cm -3. Hourly median UFP concentrations measured on the mixed route were between 3.71 × 10 4 p cm -3 and 1.55 × 10 5 p cm -3. Hourly heavy diesel vehicle (HDV) traffic volume was a very good determinant of UFP concentration in the eastbound tunnel bore ( R2 = 0.87), but much less so in the westbound bore ( R2 = 0.26). In both bores, the volume of passenger vehicles (i.e. unleaded gasoline-powered vehicles) was a significantly poorer determinant of particle concentration. When compared with similar studies reported previously, the measurements described here were among the highest recorded concentrations, which further highlights the contribution road tunnels may make to the overall UFP exposure of vehicle occupants.

  9. Reduced Ultrafine Particle Concentration in Urban Air: Changes in Nucleation and Anthropogenic Emissions.

    PubMed

    Saha, Provat K; Robinson, Ellis S; Shah, Rishabh U; Zimmerman, Naomi; Apte, Joshua S; Robinson, Allen L; Presto, Albert A

    2018-06-19

    Nucleation is an important source of ambient ultrafine particles (UFP). We present observational evidence of the changes in the frequency and intensity of nucleation events in urban air by analyzing long-term particle size distribution measurements at an urban background site in Pittsburgh, Pennsylvania during 2001-2002 and 2016-2017. We find that both frequency and intensity of nucleation events have been reduced by 40-50% over the past 15 years, resulting in a 70% reduction in UFP concentrations from nucleation. On average, the particle growth rates are 30% slower than 15 years ago. We attribute these changes to dramatic reductions in SO 2 (more than 90%) and other pollutant concentrations. Overall, UFP concentrations in Pittsburgh have been reduced by ∼48% in the past 15 years, with a ∼70% reduction in nucleation, ∼27% in weekday local sources (e.g., weekday traffic), and 49% in the regional background. Our results highlight that a reduction in anthropogenic emissions can considerably reduce nucleation events and UFP concentrations in a polluted urban environment.

  10. Workplace Measurements of Ultrafine Particles-A Literature Review.

    PubMed

    Viitanen, Anna-Kaisa; Uuksulainen, Sanni; Koivisto, Antti J; Hämeri, Kaarle; Kauppinen, Timo

    2017-08-01

    Workers are exposed to ultrafine particles (UFP) in a number of occupations. In order to summarize the current knowledge regarding occupational exposure to UFP (excluding engineered nanoparticles), we gathered information on UFP concentrations from published research articles. The aim of our study was to create a basis for future epidemiological studies that treat UFP as an exposure factor. The literature search found 72 publications regarding UFP measurements in work environments. These articles covered 314 measurement results and tabled concentrations. Mean concentrations were compared to typical urban UFP concentration level, which was considered non-occupational background concentration. Mean concentrations higher than the typical urban UFP concentration were reported in 240 workplace measurements. The results showed that workers' exposure to UFP may be significantly higher than their non-occupational exposure to background concentration alone. Mean concentrations of over 100 times the typical urban UFP concentration were reported in welding and metal industry. However, according to the results of the review, measurements of the UFP in work environments are, to date, too limited and reported too heterogeneous to allow us to draw general conclusions about workers' exposure. Harmonization of measurement strategies is essential if we are to generate more reliable and comparable data in the future. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  11. Exposure of Children to Ultrafine Particles in Primary Schools in Portugal.

    PubMed

    Rufo, João Cavaleiro; Madureira, Joana; Paciência, Inês; Slezakova, Klara; Pereira, Maria do Carmo; Pereira, Cristiana; Teixeira, João Paulo; Pinto, Mariana; Moreira, André; Fernandes, Eduardo de Oliveira

    2015-01-01

    Children spend a large part of their time at schools, which might be reflected as chronic exposure. Ultrafine particles (UFP) are generally associated with a more severe toxicity compared to fine and coarse particles, due to their ability to penetrate cell membranes. In addition, children tend to be more susceptible to UFP-mediated toxicity compared to adults, due to various factors including undeveloped immune and respiratory systems and inhalation rates. Thus, the purpose of this study was to determine indoor UFP number concentrations in Portuguese primary schools. Ultrafine particles were sampled between January and March 2014 in 10 public primary schools (35 classrooms) located in Porto, Portugal. Overall, the average indoor UFP number concentrations were not significantly different from outdoor concentrations (8.69 × 10(3) vs. 9.25 × 10(3) pt/cm(3), respectively; considering 6.5 h of indoor occupancy). Classrooms with distinct characteristics showed different trends of indoor UFP concentrations. The levels of carbon dioxide were negatively correlated with indoor UFP concentrations. Occupational density was significantly and positively correlated with UFP concentrations. Although the obtained results need to be interpreted with caution since there are no guidelines for UFP levels, special attention needs to be given to source control strategies in order to reduce major particle emissions and ensure good indoor air quality.

  12. Spatial variations in ambient ultrafine particle concentrations and the risk of incident prostate cancer: A case-control study.

    PubMed

    Weichenthal, Scott; Lavigne, Eric; Valois, Marie-France; Hatzopoulou, Marianne; Van Ryswyk, Keith; Shekarrizfard, Maryam; Villeneuve, Paul J; Goldberg, Mark S; Parent, Marie-Elise

    2017-07-01

    Diesel exhaust contains large numbers of ultrafine particles (UFPs, <0.1µm) and is a recognized human carcinogen. However, epidemiological studies have yet to evaluate the relationship between UFPs and cancer incidence. We conducted a case-control study of UFPs and incident prostate cancer in Montreal, Canada. Cases were identified from all main Francophone hospitals in the Montreal area between 2005 and 2009. Population controls were identified from provincial electoral lists of French Montreal residents and frequency-matched to cases using 5-year age groups. UFP exposures were estimated using a land use regression model. Exposures were assigned to residential locations at the time of diagnosis/recruitment as well as approximately 10-years earlier to consider potential latency between exposure and disease onset. Odds ratios (OR) and 95% confidence intervals (95% CI) were calculated per interquartile range (IQR) increase in UFPs (approximately 4000 particles/cm 3 ) using logistic regression models adjusting for individual-level and ecological covariates. Ambient UFP concentrations were associated with an increased risk of prostate cancer (OR=1.10, 95% CI: 1.01, 1.19) in fully adjusted models when exposures were assigned to residences 10-years prior to diagnosis. This risk estimate increased slightly (OR=1.17, 95% CI; 1.01, 1.35) when modeled as a non-linear natural spline function. A smaller increased risk (OR=1.04, 95% CI: 0.97, 1.11) was observed when exposures were assigned to residences at the time of diagnosis. Exposure to ambient UFPs may increase the risk of prostate cancer. Future studies are needed to replicate this finding as this is the first study to evaluate this relationship. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  13. A Laboratory Comparison of Emission Factors, Number Size Distributions, and Morphology of Ultrafine Particles from 11 Different Household Cookstove-Fuel Systems

    EPA Science Inventory

    Ultrafine particle (UFP) emissions and particle number size distributions (PNSD) are critical in the evaluation of air pollution impacts on human health and climate change. Residential cookstove emissions are a major source of many air pollutants; however, data on UFP number emis...

  14. Outdoor infiltration and indoor contribution of UFP and BC, OC, secondary inorganic ions and metals in PM2.5 in schools

    NASA Astrophysics Data System (ADS)

    Rivas, I.; Viana, M.; Moreno, T.; Bouso, L.; Pandolfi, M.; Alvarez-Pedrerol, M.; Forns, J.; Alastuey, A.; Sunyer, J.; Querol, X.

    2015-04-01

    Infiltration of outdoor-sourced particles into indoor environments in 39 schools in Barcelona was assessed during school hours. Tracers of road traffic emissions (NO2, Equivalent Black Carbon (EBC), Ultrafine Particles (UFP), Sb), secondary inorganic aerosols (SO42-, NO3-, NH4+) and a number of PM2.5 trace elements showed median indoor/outdoor (I/O) ratios ≤ 1, indicating that outdoor sources importantly contributed to indoor concentrations. Conversely, OC and mineral components had I/O ratios>1. Different infiltration factors were found for traffic and secondary components (0.31-0.75 and 0.50-0.92, cold and warm season respectively), with maxima corresponding to EBC and Cd. Higher concentrations of indoor-generated particles were observed when closed windows hindered dispersion (cold season). Building age was not a major determinant of indoor levels. Neither were the window's material, except for NO2 (with an increase of 8 μg m-3 for wood framed windows) and the mineral components (also dependent on the presence of sand in a distance <20 m) that reach the indoor environment via soil adhering to footwear with their dispersion being more barred by Aluminium/PVC framed windows than the wooden ones. Enlarged indoor concentrations of some trace elements suggest the presence of indoor sources that should be further investigated in order to achieve a healthier school indoor environment.

  15. The test of the layout of polarimeter "UFP" on the telescope AZT-2

    NASA Astrophysics Data System (ADS)

    Levchenko, T. A.; Nevodovskyi, P. V.; Vidmachenko, A. P.; Morozhenko, O. V.; Saryboha, H. V.; Zbrutsky, O. V.; Ivakhiv, O. V.

    2016-05-01

    Main Astronomical Observatory of NAS of Ukraine in cooperation with the National Technical University of Ukraine "KPI" and National University "Lviv Polytechnic" for a long time working on the design of an optical polarimeter to study of the stratospheric layer of the Earth using of orbital satellite. During this time, was accumulated a large experience of such work, and was established a layout of compact ultraviolet polarimeter (UFP) on board of satellite

  16. Continuous Near-Road Monitoring of Ultrafine Particles from 2010-2015 in Toronto, Canada

    NASA Astrophysics Data System (ADS)

    Su, Y.; Sofowote, U.; Debosz, J.; Munoz, T.

    2015-12-01

    Ultrafine particles (UFPs) have an aerodynamic diameter less than 100 nanometre (nm). Their large surface areas per unit mass favor absorption of toxic chemicals in air. UFPs could penetrate deep into the respiratory or cardiovascular systems and pose adverse health effects. Recent studies showed the association between children exposure to UFPs and their systolic blood pressure. In urban environments, primary sources of UFPs are from road traffic emissions and account for most of the total particle numbers. Controls on UPFs rely on better understanding of their emission sources and environmental behaviour. Ontario Ministry of the Environment and Climate Change have monitored UFPs since 2010 at two near-road stations in Toronto by using TSI 3031 UFP monitors. One station is located in mixed residential and industrial area and 16 meters from a major road with over 20,000 vehicles per day. The other station is surrounded by mixed residential and commercial buildings and 20 meters from a major road with over 20,000 vehicles per day. UFPs concentrations were monitored using six size channels: 20-30nm, 30-50nm, 50-70nm, 70-100nm, 100-200nm, and 200-450nm. The TSI 3031 monitors generally performed well for long-term UFP monitoring. Multi-year measurements of UFPs at the two stations show no apparent inter-annual variation or seasonality. Smaller particles (i.e., 20-50 nm) were found to be composed of over 50% of the measured particles. The observations are generally consistent with the theoretical understanding of particle nuclei mode and accumulation mode. When air mass originated from road traffic, UFPs were elevated in morning traffic hours and to a less extent in the late afternoon. The elevated UFPs number concentrations coincided with other traffic-related air pollutants like nitrogen oxides and black carbon. Moreover, higher number concentrations were found on weekdays than weekends. The observations suggest that UFPs are mostly from vehicle emissions.

  17. Measurements and predictors of on-road ultrafine particle concentrations and associated pollutants in Los Angeles

    NASA Astrophysics Data System (ADS)

    Fruin, S.; Westerdahl, D.; Sax, T.; Sioutas, C.; Fine, P. M.

    Motor vehicles are the dominant source of oxides of nitrogen (NO x), particulate matter (PM), and certain air toxics (e.g., benzene, 1,3-butadiene) in urban areas. On roadways, motor vehicle-related pollutant concentrations are typically many times higher than ambient concentrations. Due to high air exchange rates typical of moving vehicles, this makes time spent in vehicles on roadways a major source of exposure. This paper presents on-road measurements for Los Angeles freeways and arterial roads taken from a zero-emission electric vehicle outfitted with real-time instruments. The objective was to characterize air pollutant concentrations on roadways and identify the factors associated with the highest concentrations. Our analysis demonstrated that on freeways, concentrations of ultrafine particles (UFPs), black carbon, nitric oxide, and PM-bound polycyclic aromatic hydrocarbons (PM-PAH) are generated primarily by diesel-powered vehicles, despite the relatively low fraction (˜6%) of diesel-powered vehicles on Los Angeles freeways. However, UFP concentrations on arterial roads appeared to be driven primarily by proximity to gasoline-powered vehicles undergoing hard accelerations. Concentrations were roughly one-third of those on freeways. By using a multiple regression model for the freeway measurements, we were able to explain 60-70% of the variability in concentrations of UFP, black carbon, nitric oxide, and PM-PAH using measures of diesel truck density and hour of day (as an indicator of wind speed). Freeway concentrations of these pollutants were also well correlated with readily available annual average daily truck counts, potentially allowing improved population exposure estimates for epidemiology studies. Based on these roadway measurements and average driving time, it appears that 33-45% of total UFP exposure for Los Angeles residents occurs due to time spent traveling in vehicles.

  18. Ultrafine particle air pollution inside diesel-propelled passenger trains.

    PubMed

    Abramesko, Victoria; Tartakovsky, Leonid

    2017-07-01

    Locomotives with diesel engines are used worldwide and are an important source of air pollution. Pollutant emissions by locomotive engines affect the air quality inside passenger trains. This study is aimed at investigating ultrafine particle (UFP) air pollution inside passenger trains and providing a basis for assessing passenger exposure to this pollutant. The concentrations of UFPs inside the carriages of push-pull trains are dramatically higher when the train operates in pull mode. This clearly shows that locomotive engine emissions are a dominant factor in train passengers' exposure to UFPs. The highest levels of UFP air pollution are observed inside the carriages of pull trains close to the locomotive. In push mode, the UFP number concentrations were lower by factors of 2.6-43 (depending on the carriage type) compared to pull mode. The UFP concentrations are substantially lower in diesel multiple-unit trains than in trains operating in pull mode. A significant influence of the train movement regime on the UFP NC inside a carriage is observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Factors affecting pollutant concentrations in the near-road environment

    NASA Astrophysics Data System (ADS)

    Baldwin, Nichole; Gilani, Owais; Raja, Suresh; Batterman, Stuart; Ganguly, Rajiv; Hopke, Philip; Berrocal, Veronica; Robins, Thomas; Hoogterp, Sarah

    2015-08-01

    An improved understanding of traffic-related air pollutants is needed to estimate exposures and adverse health impacts in traffic corridors and near-road environments. In this study, concentrations of black carbon (BC), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and particulate matter (PM2.5, PM10, ultrafine particles, and accumulation mode particles, AMP) were measured using a mobile air pollutant laboratory along nine transects across major roads in Detroit, MI in winter 2012. Repeated measurements were taken during rush-hour periods at sites in residential neighborhoods located 50-500 m from both sides of the road. Concentration gradients attributable to on-road emissions were estimated by accounting for traffic volume and mix, wind speed, wind direction, and background concentrations. BC, NO, NOx, and UFP had the strongest gradients, and elevated concentrations of NOx, NO2, PM2.5 and PM10, as well as decreased particle size, were found at the 50 m sites compared to background levels. Exponential models incorporating effects of road size, wind speed, and up- and downwind distance explained from 31 to 53% of the variability in concentration gradients for BC, NO, NOx, UFP and particle size. The expected concentration increments 50 m from the study roads were 17.0 ppb for NO, 17.7 ppb for NOx, 2245 particles/cm3 for UFP, and 0.24 μg/m3 for BC, and the expected distance to decrease increments by half was 89-129 m in the downwind direction, and 14-20 m in the upwind direction. While accounting for portion of the temporal and spatial variability across transects and measurement periods, these results highlight the influence of road-to-road differences and other locally-varying factors important in urban and industrial settings. The study demonstrates a methodology to quantify near-road concentrations and influences on these concentrations while accounting for temporal and spatial variability, and it provides information useful for estimating exposures of

  20. Ultrafine particle levels at an international port of entry between the US and Mexico: exposure implications for users, workers, and neighbors.

    PubMed

    Olvera, Hector A; Lopez, Mario; Guerrero, Veronica; Garcia, Humberto; Li, Wen-Whai

    2013-01-01

    Exposure to diesel-emitted particles has been linked to increased cancer risk and cardiopulmonary diseases. Because of their size (<100 nm), exposure to ultrafine particles (UFPs) emitted from heavy-duty diesel vehicles (HDDV) might result in greater health risks than those associated with larger particles. Seasonal UFP levels at the International Bridge of the Americas, which connects the US and Mexico and has high HDDV traffic demands, were characterized. Hourly average UFP concentrations ranged between 1.7 × 10(3)/cc and 2.9 × 10(5)/cc with a mean of 3.5 × 10(4)/cc. Wind speeds <2 m s(-1) and temperatures <15 °C were associated with particle number concentrations above normal conditions. The presence of HDDV had the strongest impact on local UFP levels. Varying particle size distributions were associated with south- and northbound HDDV traffic. Peak exposure occurred on weekday afternoons. Although in winter, high exposure episodes were also observed in the morning. Particle number concentrations were estimated to reach background levels at 400 m away from traffic. The populations exposed to UFP above background levels include law enforcement officers, street vendors, private commuters, and commercial vehicle drivers as well as neighbors on both sides of the border, including a church and several schools.

  1. Assessment of ultrafine particles in Portuguese preschools: levels and exposure doses.

    PubMed

    Fonseca, J; Slezakova, K; Morais, S; Pereira, M C

    2014-12-01

    The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3-5-year-old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82 × 10(4) and 1.32 × 10(4) particles/cm(3) at US1 an US2, respectively) than at the rural one (1.15 × 10(4) particles/cm(3) ). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17 × 10(4) , 3.28 × 10(4) , and 4.09 × 10(4) particles/cm(3) at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31 × 10(3) , 11.3 × 10(3) , and 7.14 × 10(3) particles/cm(3) at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54-0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3-5-year-old children were exposed to 4-6 times higher UFP doses than adults with similar daily schedules. This study reports information on ultrafine particles (UFPs) in various indoor and outdoor microenvironments (canteens, classrooms, gymnasiums, and outdoor) of urban and rural preschools. It identifies the potential sources and origins, characterizes the influence of meteorological parameters on UFP levels, and performs a comparison with other existing international studies. To this date, relatively few studies have investigated UFP in preschools (none in Portugal) and none assessed exposure dose for different age-groups. The obtained findings showed that levels of UFP in

  2. Occupational Exposure to Ultrafine Particles among Airport Employees - Combining Personal Monitoring and Global Positioning System

    PubMed Central

    Møller, Karina Lauenborg; Thygesen, Lau Caspar; Schipperijn, Jasper; Loft, Steffen; Bonde, Jens Peter; Mikkelsen, Sigurd; Brauer, Charlotte

    2014-01-01

    Background Exposure to ultrafine particles (UFP) has been linked to cardiovascular and lung diseases. Combustion of jet fuel and diesel powered handling equipment emit UFP resulting in potentially high exposure levels among employees working at airports. High levels of UFP have been reported at several airports, especially on the apron, but knowledge on individual exposure profiles among different occupational groups working at an airport is lacking. Purpose The aim of this study was to compare personal exposure to UFP among five different occupational groups working at Copenhagen Airport (CPH). Method 30 employees from five different occupational groups (baggage handlers, catering drivers, cleaning staff and airside and landside security) at CPH were instructed to wear a personal monitor of particle number concentration in real time and a GPS device. The measurements were carried out on 8 days distributed over two weeks in October 2012. The overall differences between the groups were assessed using linear mixed model. Results Data showed significant differences in exposure levels among the groups when adjusted for variation within individuals and for effect of time and date (p<0.01). Baggage handlers were exposed to 7 times higher average concentrations (geometric mean, GM: 37×103 UFP/cm3, 95% CI: 25–55×103 UFP/cm3) than employees mainly working indoors (GM: 5×103 UFP/cm3, 95% CI: 2–11×103 UFP/cm3). Furthermore, catering drivers, cleaning staff and airside security were exposed to intermediate concentrations (GM: 12 to 20×103 UFP/cm3). Conclusion The study demonstrates a strong gradient of exposure to UFP in ambient air across occupational groups of airport employees. PMID:25203510

  3. Occupational exposure to ultrafine particles among airport employees--combining personal monitoring and global positioning system.

    PubMed

    Møller, Karina Lauenborg; Thygesen, Lau Caspar; Schipperijn, Jasper; Loft, Steffen; Bonde, Jens Peter; Mikkelsen, Sigurd; Brauer, Charlotte

    2014-01-01

    Exposure to ultrafine particles (UFP) has been linked to cardiovascular and lung diseases. Combustion of jet fuel and diesel powered handling equipment emit UFP resulting in potentially high exposure levels among employees working at airports. High levels of UFP have been reported at several airports, especially on the apron, but knowledge on individual exposure profiles among different occupational groups working at an airport is lacking. The aim of this study was to compare personal exposure to UFP among five different occupational groups working at Copenhagen Airport (CPH). 30 employees from five different occupational groups (baggage handlers, catering drivers, cleaning staff and airside and landside security) at CPH were instructed to wear a personal monitor of particle number concentration in real time and a GPS device. The measurements were carried out on 8 days distributed over two weeks in October 2012. The overall differences between the groups were assessed using linear mixed model. Data showed significant differences in exposure levels among the groups when adjusted for variation within individuals and for effect of time and date (p<0.01). Baggage handlers were exposed to 7 times higher average concentrations (geometric mean, GM: 37×103 UFP/cm(3), 95% CI: 25-55 × 10(3) UFP/cm(3)) than employees mainly working indoors (GM: 5 × 10(3) UFP/cm(3), 95% CI: 2-11 × 103 UFP/cm(3)). Furthermore, catering drivers, cleaning staff and airside security were exposed to intermediate concentrations (GM: 12 to 20 × 10(3) UFP/cm(3)). The study demonstrates a strong gradient of exposure to UFP in ambient air across occupational groups of airport employees.

  4. Evaluation of critical indicators in the process of acquiring supplies and services LAC-UFPE

    NASA Astrophysics Data System (ADS)

    Caetano, V. F.; Ferreira, C. V.; dos Santos, M. J.; Honorato, F. A.

    2015-01-01

    In laboratories linked to public universities and accredited by the NBR ISO/IEC 17025, to meet efficiently item 4.6 (procurement of supplies and services) is a challenge that can be accomplished by programming based on historical purchases and services. In this study, we evaluated the critical procurement items to meet the quality management system of the LAC-UFPE: reagents, certified reference material, of equipment parts, maintenance and calibration of equipment and instruments. It was found that the most critical item is the certified reference material, the purchase or repair of which must be expedited within 125 days prior to the receipt to occur within the desired period.

  5. The association between the incidence of postmenopausal breast cancer and concentrations at street-level of nitrogen dioxide and ultrafine particles.

    PubMed

    Goldberg, Mark S; Labrèche, France; Weichenthal, Scott; Lavigne, Eric; Valois, Marie-France; Hatzopoulou, Marianne; Van Ryswyk, Keith; Shekarrizfard, Maryam; Villeneuve, Paul J; Crouse, Daniel; Parent, Marie-Élise

    2017-10-01

    There is scant information as to whether traffic-related air pollution is associated with the incidence of breast cancer. Nitrogen dioxide (NO 2 ) and ultrafine particles (UFPs, <0.1µm), are two pollutants that capture intra-urban variations in traffic-related air pollution and may also be associated with incidence. We conducted a population-based, case-control study of street-level concentrations of NO 2 and UFPs and incident postmenopausal breast cancer in Montreal, Canada. Incident cases were identified between 2008 and 2011 from all but one hospital that treated breast cancer in the Montreal area. Population controls were identified from provincial electoral lists of Montreal residents and frequency-matched to cases using 5-year age groups. Concentrations of NO 2 and UFPs were estimated using two separate land-use regression models. Exposures were assigned to residential locations at the time of recruitment, and we identified residential histories of women who had lived in these residences for 10 years or more. Odds ratios (OR) and 95% confidence intervals (CI) were estimated using logistic regression models adjusting for individual-level and ecological covariates. We assessed the functional form of NO 2 and UFP exposures using natural cubic splines. We found that the functional form of the response functions between incident postmenopausal breast cancer and concentrations of NO 2 and UFPs were consistent with linearity. For NO 2 , we found increasing risks of breast cancer for all subjects combined and stronger associations when analyses were restricted to those women who had lived at their current address for 10 years or more. Specifically, the OR, adjusted for personal covariates, per increase in the interquartile range (IQR=3.75 ppb) of NO 2 was 1.08 (95%CI: 0.92-1.27). For women living in their homes for 10 years or more, the adjusted OR was 1.17 (95%CI: 0.93-1.46; IQR=3.84 ppb); for those not living at that home 10 years before the study, it was 0.93 (95

  6. Concentration levels and source apportionment of ultrafine particles in road microenvironments

    NASA Astrophysics Data System (ADS)

    Argyropoulos, G.; Samara, C.; Voutsa, D.; Kouras, A.; Manoli, E.; Voliotis, A.; Tsakis, A.; Chasapidis, L.; Konstandopoulos, A.; Eleftheriadis, K.

    2016-03-01

    A mobile laboratory unit (MOBILAB) with on-board instrumentation (Scanning Mobility Particle Sizer, SMPS; Ambient NOx analyzer) was used to measure size-resolved particle number concentrations (PNCs) of quasi-ultrafine particles (UFPs, 9-372 nm), along with NOx, in road microenvironments. On-road measurements were carried out in and around a large Greek urban agglomeration, the Thessaloniki Metropolitan Area (TMA). Two 2-week measurement campaigns were conducted during the warm period of 2011 and the cold period of 2012. During each sampling campaign, MOBILAB was driven through a 5-day inner-city route and a second 5-day external route covering in total a wide range of districts (urban, urban background, industrial and residential), and road types (major and minor urban roads, freeways, arterial and interurban roads). All routes were conducted during working days, in morning and in afternoon hours under real-world traffic conditions. Spatial classification of MOBILAB measurements involved the assignment of measurement points to location bins defined by the aspect ratio of adjacent urban street canyons (USCs). Source apportionment was further carried out, by applying Positive Matrix Factorization (PMF) to particle size distribution data. Apportioned PMF factors were interpreted, by employing a two-step methodology, which involved (a) statistical association of PMF factor contributions with 12 h air-mass back-trajectories ending at the TMA during MOBILAB measurements, and (b) Multiple Linear Regression (MLR) using PMF factor contributions as the dependent variables, while relative humidity, solar radiation flux, and vehicle speed were used as the independent variables. The applied data analysis showed that low-speed cruise and high-load engine operation modes are the two dominant sources of UFPs in most of the road microenvironments in the TMA, with significant contributions from background photochemical processes during the warm period, explaining the reversed

  7. Variation and co-variation of PM10, particle number concentration, NOx and NO2 in the urban air - Relationships with wind speed, vertical temperature gradient and weather type

    NASA Astrophysics Data System (ADS)

    Grundström, M.; Hak, C.; Chen, D.; Hallquist, M.; Pleijel, H.

    2015-11-01

    Atmospheric ultrafine particles (UFP; diameter < 0.1 μm) represent a growing global health concern in urban environments and has a strong link to traffic related emissions. UFP is usually the dominating fraction of atmospheric particle number concentrations (PNC) despite being a minor part of total particle mass. The aim of this study was to empirically investigate the relationship between PNC and other air pollutants (NOX, NO2 and PM10) in the urban environment and their dependence on meteorology and weather type, using the Lamb Weather Type (LWT) classification scheme. The study was carried out in Gothenburg, Sweden, at an urban background site during April 2007-May 2008. It was found that daily average [PNC] correlated very well with [NOx] (R2 = 0.73) during inversion days, to a lesser extent with [NO2] (R2 = 0.58) and poorly with [PM10] (R2 = 0.07). Both PNC and NOx had similar response patterns to wind speed and to the strength of temperature inversions. PNC displayed two regimes, one strongly correlated to NOx and a second poorly correlated to NOx which was characterised by high wind speed. For concentration averages based on LWTs, the PNC-[NOx] relationship remained strong (R2 = 0.70) where the windy LWT W deviated noticeably. Exclusion of observations with wind speed >5 ms-1 or ΔT < 0 °C from LWTs produced more uniform and stronger relationships (R2 = 0.90; R2 = 0.93). Low wind speeds and positive vertical temperature gradients were most common during LWTs A, NW, N and NE. These weather types were also associated with the highest daily means of NOx (∼30 ppb) and PNC (∼10 000 # cm-3). A conclusion from this study is that NOx (but not PM10) is a good proxy for PNC especially during calm and stable conditions and that LWTs A, NW, N and NE are high risk weather types for elevated NOx and PNC.

  8. Fine and ultrafine particle emissions from microwave popcorn.

    PubMed

    Zhang, Q; Avalos, J; Zhu, Y

    2014-04-01

    This study characterized fine (PM2.5 ) and ultrafine particle (UFP, diameter < 100 nm) emissions from microwave popcorn and analyzed influential factors. Each pre-packed popcorn bag was cooked in a microwave oven enclosed in a stainless steel chamber for 3 min. The number concentration and size distribution of UFPs and PM2.5 mass concentration were measured inside the chamber repeatedly for five different flavors under four increasing power settings using either the foil-lined original package or a brown paper bag. UFPs and PM2.5 generated by microwaving popcorn were 150-560 and 350-800 times higher than the emissions from microwaving water, respectively. About 90% of the total particles emitted were in the ultrafine size range. The emitted PM concentrations varied significantly with flavor. Replacing the foil-lined original package with a brown paper bag significantly reduced the peak concentration by 24-87% for total particle number and 36-70% for PM2.5 . A positive relationship was observed between both UFP number and PM2.5 mass and power setting. The emission rates of microwave popcorn ranged from 1.9 × 10(10) to 8.0 × 10(10) No./min for total particle number and from 134 to 249 μg/min for PM2.5 . © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Ultrafine particles from power plants: Evaluation of WRF-Chem simulations with airborne measurements

    NASA Astrophysics Data System (ADS)

    Forkel, Renate; Junkermann, Wolfgang

    2017-04-01

    Ultrafine particles (UFP, particles with a diameter < 100 nm) are an acknowledged risk to human health and have a potential effect on climate as their presence affects the number concentration of cloud condensation nuclei. Despite of the possibly hazardous effects no regulations exist for this size class of ambient air pollution particles. While ground based continuous measurements of UFP are performed in Germany at several sites (e.g. the German Ultrafine Aerosol Network GUAN, Birmili et al. 2016, doi:10.5194/essd-8-355-2016) information about the vertical distribution of UFP within the atmospheric boundary layer is only scarce. This gap has been closed during the last years by regional-scale airborne surveys for UFP concentrations and size distributions over Germany (Junkermann et al., 2016, doi: 10.3402/tellusb.v68.29250) and Australia (Junkermann and Hacker, 2015, doi: 10.3402/tellusb.v67.25308). Power stations and refineries have been identified as a major source of UFP in Germany with observed particle concentrations > 50000 particles cm-3 downwind of these elevated point sources. Nested WRF-Chem simulations with 2 km grid width for the innermost domain are performed with UFP emission source strengths derived from the measurements in order to study the advection and vertical exchange of UFP from power plants near the Czech and Polish border and their impact on planetary boundary layer particle patterns. The simulations are evaluated against the airborne observations and the downward mixing of the UFP from the elevated sources is studied.

  10. Air quality in the German-Czech border region: A focus on harmful fractions of PM and ultrafine particles

    NASA Astrophysics Data System (ADS)

    Schladitz, Alexander; Leníček, Jan; Beneš, Ivan; Kováč, Martin; Skorkovský, Jiří; Soukup, Aleš; Jandlová, Jana; Poulain, Laurent; Plachá, Helena; Löschau, Gunter; Wiedensohler, Alfred

    2015-12-01

    A comprehensive air quality study has been carried out at two urban background sites in Annaberg-Buchholz (Germany) and Ústí nad Labem (Czech Republic) in the German-Czech border region between January 2012 and June 2014. Special attention was paid to quantify harmful fractions of particulate matter (PM) and ultrafine particle number concentration (UFP) from solid fuel combustion and vehicular traffic. Source type contributions of UFP were quantified by using the daily concentration courses of UFP and nitrogen oxide. Two different source apportionment techniques were used to quantify relative and absolute mass contributions: positive matrix factorization for total PM2.5 and elemental carbon in PM2.5 and chemical mass balance for total PM1 and organic carbon in PM1. Contributions from solid fuel combustion strongly differed between the non-heating period (April-September) and the heating period (October-March). Major sources of solid fuel combustion in this study were wood and domestic coal combustion, while the proportion of industrial coal combustion was low (<3%). In Ústí nad Labem combustion of domestic brown coal was the most important source of organic carbon ranging from 34% to 43%. Wood combustion was an important source of organic carbon in Annaberg-Buchholz throughout the year. Heavy metals and less volatile polycyclic aromatic hydrocarbons (PAH) in the accumulation mode were related to solid fuel combustion with enhanced concentrations during the heating period. In contrast, vehicular PAH emissions were allocated to the Aitken mode. Only in Ústí nad Labem a significant contribution of photochemical new particle formation (e.g. from sulfur dioxide) to UFP of almost 50% was observed during noontime. UFPs from traffic emissions (nucleation particles) and primary emitted soot particles dominated at both sites during the rest of the day. The methodology of a combined source apportionment of UFP and PM can be adapted to other regions of the world with

  11. Workplace exposure and release of ultrafine particles during atmospheric plasma spraying in the ceramic industry.

    PubMed

    Viana, M; Fonseca, A S; Querol, X; López-Lilao, A; Carpio, P; Salmatonidis, A; Monfort, E

    2017-12-01

    Atmospheric plasma spraying (APS) is a frequently used technique to produce enhanced-property coatings for different materials in the ceramic industry. This work aimed to characterise and quantify the impact of APS on workplace exposure to airborne particles, with a focus on ultrafine particles (UFPs, <100nm) and nanoparticles (<50nm). Particle number, mass concentrations, alveolar lung deposited surface area concentration, and size distributions, in the range 10nm-20μm were simultaneously monitored at the emission source, in the potential worker breathing zone, and in outdoor air. Different input materials (known as feedstock) were tested: (a) micron-sized powders, and (b) suspensions containing submicron- or nano-sized particles. Results evidenced significantly high UFP concentrations (up to 3.3×10 6 /cm 3 ) inside the spraying chamber, which impacted exposure concentrations in the worker area outside the spraying chamber (up to 8.3×10 5 /cm 3 ). Environmental release of UFPs was also detected (3.9×10 5 /cm 3 , outside the exhaust tube). Engineered nanoparticle (ENP) release to workplace air was also evidenced by TEM microscopy. UFP emissions were detected during the application of both micron-sized powder and suspensions containing submicron- or nano-sized particles, thus suggesting that emissions were process- (and not material-) dependent. An effective risk prevention protocol was implemented, which resulted in a reduction of UFP exposure in the worker area. These findings demonstrate the potential risk of occupational exposure to UFPs during atmospheric plasma spraying, and raise the need for further research on UFP formation mechanisms in high-energy industrial processes. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Particulate Matter Exposure in a Police Station Located near a Highway.

    PubMed

    Chen, Yu-Cheng; Hsu, Chin-Kai; Wang, Chia C; Tsai, Perng-Jy; Wang, Chun-Yuan; Chen, Mei-Ru; Lin, Ming-Yeng

    2015-11-13

    People living or working near roadways have experienced an increase in cardiovascular or respiratory diseases due to vehicle emissions. Very few studies have focused on the PM exposure of highway police officers, particularly for the number concentration and size distribution of ultrafine particles (UFP). This study evaluated exposure concentrations of particulate matter (PM) in the Sinying police station near a highway located in Tainan, Taiwan, under different traffic volumes, traffic types, and shift times. We focused on periods when the wind blew from the highway toward the police station and when the wind speed was greater than or equal to 0.5 m/s. PM2.5, UFP, and PM-PAHs concentrations in the police station and an upwind reference station were measured. Results indicate that PM2.5, UFP, and PM-PAHs concentrations in the police station can be on average 1.13, 2.17, and 5.81 times more than the upwind reference station concentrations, respectively. The highest exposure level for PM2.5 and UFP was observed during the 12:00 PM-4:00 PM shift while the highest PAHs concentration was found in the 4:00 AM-8:00 AM shift. Thus, special attention needs to be given to protect police officers from exposure to high PM concentration.

  13. Particulate Matter Exposure in a Police Station Located near a Highway

    PubMed Central

    Chen, Yu-Cheng; Hsu, Chin-Kai; Wang, Chia C.; Tsai, Perng-Jy; Wang, Chun-Yuan; Chen, Mei-Ru; Lin, Ming-Yeng

    2015-01-01

    People living or working near roadways have experienced an increase in cardiovascular or respiratory diseases due to vehicle emissions. Very few studies have focused on the PM exposure of highway police officers, particularly for the number concentration and size distribution of ultrafine particles (UFP). This study evaluated exposure concentrations of particulate matter (PM) in the Sinying police station near a highway located in Tainan, Taiwan, under different traffic volumes, traffic types, and shift times. We focused on periods when the wind blew from the highway toward the police station and when the wind speed was greater than or equal to 0.5 m/s. PM2.5, UFP, and PM-PAHs concentrations in the police station and an upwind reference station were measured. Results indicate that PM2.5, UFP, and PM-PAHs concentrations in the police station can be on average 1.13, 2.17, and 5.81 times more than the upwind reference station concentrations, respectively. The highest exposure level for PM2.5 and UFP was observed during the 12:00 PM–4:00 PM shift while the highest PAHs concentration was found in the 4:00 AM–8:00 AM shift. Thus, special attention needs to be given to protect police officers from exposure to high PM concentration. PMID:26580641

  14. Multi-metric measurement of personal exposure to ultrafine particles in selected urban microenvironments

    NASA Astrophysics Data System (ADS)

    Spinazzè, Andrea; Cattaneo, Andrea; Scocca, Damiano R.; Bonzini, Matteo; Cavallo, Domenico M.

    2015-06-01

    At the beginning of the study, our hypothesis was that visiting certain microenvironments (MEs) is one of the most important determinants of personal exposure to ultrafine particles (UFP) and that moving between microenvironments significantly differentiates exposure. The overall aim of this study is to perform relevant exposure measurements to extend our knowledge on environmental exposure to UFP in urban environments. The UFP concentrations in different urban MEs were measured by personal monitoring in repeated sampling campaigns along a fixed route. The measurement runs were performed on one-week periods and at different times of day (AM: 08.00-10.30; PM: 16.00-18.30) and repeated in different periods of the year (winter, spring, summer, and autumn) for a total of 56 runs (>110 h). Measurements included on-line monitoring of the UFP particle number concentration (PNC), mean diameter (mean-d) and lung-deposited surface-area (LDSA). Additionally, the PNC, particle mass concentration (PMC) profiles for quasi-ultrafine particles (QUFP; PM0.25) were estimated. A significant seasonal difference in the PNC and PMC, mean diameter and surface area was observed as well as between different times of the day and days of the week. In addition, differences in the UFP concentrations were also found in each ME, and there were specific mean-diameter and surface area concentrations. In general, the mean particle diameters showed an inverse relationship with the PNC, while the LDSA had the opposite behaviour. Appreciable differences among all MEs and monitoring periods were observed; the concentration patterns and variations seemed related to the typical sources of urban pollutants (traffic), proximity to sources and time of day. The highest exposures were observed for walking or biking along high-trafficked routes and while using public buses. The UFP exposure levels in modern cars, equipped with high-efficiency filters and in air recirculation mode, were significantly lower.

  15. Frequent ultrafine particle formation and growth in Canadian Arctic marine and coastal environments

    NASA Astrophysics Data System (ADS)

    Collins, Douglas B.; Burkart, Julia; Chang, Rachel Y.-W.; Lizotte, Martine; Boivin-Rioux, Aude; Blais, Marjolaine; Mungall, Emma L.; Boyer, Matthew; Irish, Victoria E.; Massé, Guillaume; Kunkel, Daniel; Tremblay, Jean-Éric; Papakyriakou, Tim; Bertram, Allan K.; Bozem, Heiko; Gosselin, Michel; Levasseur, Maurice; Abbatt, Jonathan P. D.

    2017-11-01

    The source strength and capability of aerosol particles in the Arctic to act as cloud condensation nuclei have important implications for understanding the indirect aerosol-cloud effect within the polar climate system. It has been shown in several Arctic regions that ultrafine particle (UFP) formation and growth is a key contributor to aerosol number concentrations during the summer. This study uses aerosol number size distribution measurements from shipboard expeditions aboard the research icebreaker CCGS Amundsen in the summers of 2014 and 2016 throughout the Canadian Arctic to gain a deeper understanding of the drivers of UFP formation and growth within this marine boundary layer. UFP number concentrations (diameter > 4 nm) in the range of 101-104 cm-3 were observed during the two seasons, with concentrations greater than 103 cm-3 occurring more frequently in 2016. Higher concentrations in 2016 were associated with UFP formation and growth, with events occurring on 41 % of days, while events were only observed on 6 % of days in 2014. Assessment of relevant parameters for aerosol nucleation showed that the median condensation sink in this region was approximately 1.2 h-1 in 2016 and 2.2 h-1 in 2014, which lie at the lower end of ranges observed at even the most remote stations reported in the literature. Apparent growth rates of all observed events in both expeditions averaged 4.3 ± 4.1 nm h-1, in general agreement with other recent studies at similar latitudes. Higher solar radiation, lower cloud fractions, and lower sea ice concentrations combined with differences in the developmental stage and activity of marine microbial communities within the Canadian Arctic were documented and help explain differences between the aerosol measurements made during the 2014 and 2016 expeditions. These findings help to motivate further studies of biosphere-atmosphere interactions within the Arctic marine environment to explain the production of UFP and their growth to sizes

  16. Measurements of fine and ultrafine particles formation in photocopy centers in Taiwan

    NASA Astrophysics Data System (ADS)

    Lee, Chia-Wei; Hsu, Der-Jen

    This study investigates the levels of particulate matter smaller than 2.5 μm (PM 2.5) and some selected volatile organic compounds (VOCs) at 12 photocopy centers in Taiwan from November 2004 to June 2005. The results of BTEXS (benzene, toluene, ethylbenzene, xylenes and styrene) measurements indicated that toluene had the highest concentration in all photocopy centers, while the concentration of the other four compounds varied among the 12 photocopy centers. The average background-corrected eight-hour PM 2.5 in the 12 photocopy centers ranged from 10 to 83 μg m -3 with an average of 40 μg m -3. The 24-h indoor PM 2.5 at the photocopy centers was estimated and at two photocopy centers exceeded 100 μg m -3, the 24-h indoor PM 2.5 guideline recommended by the Taiwan EPA. The ozone level and particle size distribution at another photocopy center were monitored and indicated that the ozone level increased when the photocopying started and the average ozone level at some photocopy centers during business hour may exceed the value (50 ppb) recommended by the Taiwan EPA. The particle size distribution monitored during photocopying indicated that the emitted particles were much smaller than the original toner powders. Additionally, the number concentration of particles that were smaller than 0.5 μm was found to increase during the first hour of photocopying and it increased as the particle size decreased. The ultrafine particle (UFP, <100 nm) dominated the number concentration and the peak concentration appeared at sizes of under 50 nm. A high number concentration of UFP was found with a peak value of 1E+8 particles cm -3 during photocopying. The decline of UFP concentration was observed after the first hour and the decline is likely attributable to the surface deposition of charged particles, which are charged primarily by the diffusion charging of corona devices in the photocopier. This study concludes that ozone and UFP concentrations in photocopy centers should be

  17. Physicochemical characteristics and occupational exposure to coarse, fine and ultrafine particles during building refurbishment activities

    NASA Astrophysics Data System (ADS)

    Azarmi, Farhad; Kumar, Prashant; Mulheron, Mike; Colaux, Julien L.; Jeynes, Chris; Adhami, Siavash; Watts, John F.

    2015-08-01

    Understanding of the emissions of coarse (PM10 ≤10 μm), fine (PM2.5 ≤2.5 μm) and ultrafine particles (UFP <100 nm) from refurbishment activities and their dispersion into the nearby environment is of primary importance for developing efficient risk assessment and management strategies in the construction and demolition industry. This study investigates the release, occupational exposure and physicochemical properties of particulate matter, including UFPs, from over 20 different refurbishment activities occurring at an operational building site. Particles were measured in the 5-10,000-nm-size range using a fast response differential mobility spectrometer and a GRIMM particle spectrometer for 55 h over 8 days. The UFPs were found to account for >90 % of the total particle number concentrations and <10 % of the total mass concentrations released during the recorded activities. The highest UFP concentrations were 4860, 740, 650 and 500 times above the background value during wall-chasing, drilling, cementing and general demolition activities, respectively. Scanning electron microscopy, X-ray photoelectron spectroscopy and ion beam analysis were used to identify physicochemical characteristics of particles and attribute them to probable sources considering the size and the nature of the particles. The results confirm that refurbishment activities produce significant levels (both number and mass) of airborne particles, indicating a need to develop appropriate regulations for the control of occupational exposure of operatives undertaking building refurbishment.

  18. [Distribution of atmospheric ultrafine particles during haze weather in Hangzhou].

    PubMed

    Chen, Qiu-Fang; Sun, Zai; Xie, Xiao-Fang

    2014-08-01

    Atmospheric ultrafine particles (UFPs) were monitored with fast mobility particle sizer (FMPS) in continuous haze weather and the haze fading process during December 6 to 11, 2013 in Hangzhou. Particle concentration and size distribution were studied associated with meteorological factors. The results showed that number concentrations were the highest at night and began to reduce in the morning. There was a small peak at 8 o'clock in the morning and 18 o'clock in the afternoon. It showed an obvious peak traffic source, which indicated that traffic emissions played a great role in the atmospheric pollution. During haze weather, the highest number concentration of UFPs reached 8 x 10(4) cm(-3). Particle size spectrum distribution was bimodal, the peak particle sizes were 15 nm and 100 nm respectively. Majority of UFPs were Aitken mode and Accumulation mode and the size of most particles concentrated near 100 nm. Average CMD(count medium diameter) was 85.89 nm. During haze fading process, number concentration and particles with size around 100 nm began to reduce and peak size shifted to small size. Nuclear modal particles increased and were more than accumulation mode. Average CMD was 58.64 nm. Meteorological factors such as the visibility and wind were negatively correlated with the particle number concentration. Correlation coefficient R were -0.225 and - 0.229. The humidity was correlated with number concentration. Correlation coefficient R was 0.271. The atmosphere was stable in winter and the level temperature had small correlation with number concentration. Therefore, study on distribution of atmospheric ultrafine particles during haze weather had the significance on the formation mechanism and control of haze weather.

  19. Measurements of ultrafine particles and other vehicular pollutants inside school buses in South Texas

    NASA Astrophysics Data System (ADS)

    Zhang, Qunfang; Zhu, Yifang

    2010-01-01

    Increasing evidence has demonstrated toxic effects of vehicular emitted ultrafine particles (UFPs, diameter < 100 nm), with the highest human exposure usually occurring on and near roadways. Children are particularly at risk due to immature respiratory systems and faster breathing rates. In this study, children's exposure to in-cabin air pollutants, especially UFPs, was measured inside four diesel-powered school buses. Two 1990 and two 2006 model year diesel-powered school buses were selected to represent the age extremes of school buses in service. Each bus was driven on two routine bus runs to study school children's exposure under different transportation conditions in South Texas. The number concentration and size distribution of UFPs, total particle number concentration, PM 2.5, PM 10, black carbon (BC), CO, and CO 2 levels were monitored inside the buses. The average total particle number concentrations observed inside the school buses ranged from 7.3 × 10 3 to 3.4 × 10 4 particles cm -3, depending on engine age and window position. When the windows were closed, the in-cabin air pollutants were more likely due to the school buses' self-pollution. The 1990 model year school buses demonstrated much higher air pollutant concentrations than the 2006 model year ones. When the windows were open, the majority of in-cabin air pollutants came from the outside roadway environment with similar pollutant levels observed regardless of engine ages. The highest average UFP concentration was observed at a bus transfer station where approximately 27 idling school buses were queued to load or unload students. Starting-up and idling generated higher air pollutant levels than the driving state. Higher in-cabin air pollutant concentrations were observed when more students were on board.

  20. Contributions of aircraft arrivals and departures to ultrafine particle counts near Los Angeles International Airport.

    PubMed

    Hsu, Hsiao-Hsien; Adamkiewicz, Gary; Houseman, E Andres; Zarubiak, Darcy; Spengler, John D; Levy, Jonathan I

    2013-02-01

    While commercial aircraft are known sources of ultrafine particulate matter (UFP), the relationship between airport activity and local real-time UFP concentrations has not been quantified. Understanding these associations will facilitate interpretation of the exposure and health risk implications of UFP related to aviation emissions. We used time-resolved UFP data along with flight activity and meteorological information to determine the contributions of aircraft departures and arrivals to UFP concentrations. Aircraft flight activity and near-field continuous UFP concentrations (≧ 6 nm) were measured at five monitoring sites over a 42-day field campaign at Los Angeles International Airport (LAX). We developed regression models of UFP concentrations as a function of time-lagged landing and take-off operations (LTO) activity, in the form of arrivals or departures weighted by engine-specific estimates of fuel consumption. Our regression models demonstrate a strong association between departures and elevated total UFP concentrations at the end of the departure runway, with diminishing magnitude and time-lagged impacts with distance from the source. LTO activity contributed a median (95th, 99th percentile) UFP concentration of approximately 150,000 particles/cm(3) (2,000,000, 7,100,000) at a monitor at the end of the departure runway, versus 19,000 particles/cm(3) (80,000, 140,000), and 17,000 particles/cm(3) (50,000, 72,000) for monitors 250 m and 500 m further downwind, respectively. We demonstrated significant contributions from aircraft departure activities to UFP concentrations in close proximity to departure runways, with evidence of rapid plume evolution in the near field. Our methods can inform source attribution and interpretation of dispersion modeling outputs. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Personal exposure to airborne ultrafine particles in the urban area of Milan

    NASA Astrophysics Data System (ADS)

    Cattaneo, A.; Garramone, G.; Taronna, M.; Peruzzo, C.; Cavallo, D. M.

    2009-02-01

    The relevance of health effects related to ultrafine particles (UFPs; aerodynamic diameter < 100 nm) can be better evaluated using high-resolution strategies for measuring particle number concentrations. In this study, two different portable Condensation Particle Counters (CPCs) were used to measure personal exposure to UFPs in the central area of Milan for one week period during spring, with three sampling sessions per day. Experimental data were continuously collected along an established urban pathway, moving afoot or by different private and public means of transport. Correlation analysis between data measured by two CPCs was performed and general results showed a good agreement, especially at concentrations lower than 2×105 particles /cm3. UFPs measures were divided on the basis of crossed environments or micro-environments, days of the week and day time (hours). The highest measured mean concentrations and data variability were observed during walking time and moving on motorized vehicles (bus and car), indicating that the highest exposure to UFPs can be reached near motorized traffic. The lowest exposures were observed in green areas and in office microenvironments. An appreciable difference between working and non-working days was observed. Concentration patterns and variation by days of the week and time periods appears related to time trends in traffic intensity.

  2. Multisite study of particle number concentrations in urban air.

    PubMed

    Harrison, Roy M; Jones, Alan M

    2005-08-15

    Particle number concentration data are reported from a total of eight urban site locations in the United Kingdom. Of these, six are central urban background sites, while one is an urban street canyon (Marylebone Road) and another is influenced by both a motorway and a steelworks (Port Talbot). The concentrations are generally of a similar order to those reported in the literature, although higher than those in some of the other studies. Highest concentrations are at the Marylebone Road site and lowest are at the Port Talbot site. The central urban background locations lie somewhere between with concentrations typically around 20 000 cm(-3). A seasonal pattern affects all sites, with highest concentrations in the winter months and lowest concentrations in the summer. Data from all sites show a diurnal variation with a morning rush hour peak typical of an anthropogenic pollutant. When the dilution effects of windspeed are accounted for, the data show little directionality at the central urban background sites indicating the influence of sources from all directions as might be expected if the major source were road traffic. At the London Marylebone Road site there is high directionality driven by the air circulation in the street canyon, and at the Port Talbot site different diurnal patterns are seen for particle number count and PM10 influenced by emissions from road traffic (particle number count) and the steelworks (PM10) and local meteorological factors. Hourly particle number concentrations are generally only weakly correlated to NO(x) and PM10, with the former showing a slightly closer relationship. Correlations between daily average particle number count and PM10 were also weak. Episodes of high PM10 concentration in summer typically show low particle number concentrations consistent with transport of accumulation mode secondary aerosol, while winter episodes are frequently associated with high PM10 and particle number count arising from poor dispersion of

  3. Evaluation of long-term surface-retrieved cloud droplet number concentration with in situ aircraft observations: ARM Cloud Droplet Number Concentration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Kyo-Sun Sunny; Riihimaki, Laura; Comstock, Jennifer M.

    A new cloud-droplet number concentration (NDROP) value added product (VAP) has been produced at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site for the 13 years from January 1998 to January 2011. The retrieval is based on surface radiometer measurements of cloud optical depth from the multi-filter rotating shadow-band radiometer (MFRSR) and liquid water path from the microwave radiometer (MWR). It is only applicable for single-layered warm clouds. Validation with in situ aircraft measurements during the extended-term aircraft field campaign, Routine ARM Aerial Facility (AAF) CLOWD Optical Radiative Observations (RACORO), shows that the NDROP VAP robustly reproduces themore » primary mode of the in situ measured probability density function (PDF), but produces a too wide distribution, primarily caused by frequent high cloud-droplet number concentration. Our analysis shows that the error in the MWR retrievals at low liquid water paths is one possible reason for this deficiency. Modification through the diagnosed liquid water path from the coordinate solution improves not only the PDF of the NDROP VAP but also the relationship between the cloud-droplet number concentration and cloud-droplet effective radius. Consideration of entrainment effects rather than assuming an adiabatic cloud improves the values of the NDROP retrieval by reducing the magnitude of cloud-droplet number concentration. Aircraft measurements and retrieval comparisons suggest that retrieving the vertical distribution of cloud-droplet number concentration and effective radius is feasible with an improvement of the parameter representing the mixing effects between environment and clouds and with a better understanding of the effect of mixing degree on cloud properties.« less

  4. Neuropathological Consequences of Gestational Exposure to Concentrated Ambient Fine and Ultrafine Particles in the Mouse.

    PubMed

    Klocke, Carolyn; Allen, Joshua L; Sobolewski, Marissa; Mayer-Pröschel, Margot; Blum, Jason L; Lauterstein, Dana; Zelikoff, Judith T; Cory-Slechta, Deborah A

    2017-04-01

    Increasing evidence indicates that the central nervous system (CNS) is a target of air pollution. We previously reported that postnatal exposure of mice to concentrated ambient ultrafine particles (UFP; ≤100 nm) via the University of Rochester HUCAPS system during a critical developmental window of CNS development, equivalent to human 3rd trimester, produced male-predominant neuropathological and behavioral characteristics common to multiple neurodevelopmental disorders, including autism spectrum disorder (ASD), in humans. The current study sought to determine whether vulnerability to fine (≤2.5 μm) and UFP air pollution exposure extends to embryonic periods of brain development in mice, equivalent to human 1st and 2nd trimesters. Pregnant mice were exposed 6 h/day from gestational days (GDs) 0.5-16.5 using the New York University VACES system to concentrated ambient fine/ultrafine particles at an average concentration of 92.69 μg/m3 over the course of the exposure period. At postnatal days (PNDs) 11-15, neuropathological consequences were characterized. Gestational air pollution exposures produced ventriculomegaly, increased corpus callosum (CC) area and reduced hippocampal area in both sexes. Both sexes demonstrated CC hypermyelination and increased microglial activation and reduced total CC microglia number. Analyses of iron deposition as a critical component of myelination revealed increased iron deposition in the CC of exposed female offspring, but not in males. These findings demonstrate that vulnerability of the brain to air pollution extends to gestation and produces features of several neurodevelopmental disorders in both sexes. Further, they highlight the importance of the commonalities of components of particulate matter exposures as a source of neurotoxicity and common CNS alterations. © The Author 2017. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e

  5. Associations Between Ultrafine Particles and Co-Pollutant Concentrations in the Tampa Bay Area.

    PubMed

    Desai, Ushang; Watson, Alain

    2016-05-01

    Ultrafine particles (UFPs) are ubiquitous in urban air and have been recognized as a risk to human health. The aim of this study was to measure the relationships among ultrafine particles and other ambient air pollutants and meteorological factors in the Tampa Bay Area. This study measured continuous UFPs, black carbon, oxides of nitrogen (NO(x)), nitrogen dioxide (NO2), nitric oxide (NO), carbon monoxide (CO), ozone (O3), sulfur dioxide (SO2), particulate matter having an aerodynamic diameter of 10 microns or less (PM10), relative humidity, wind speed, and ambient temperature during January to March 2014. Moreover, the study compared the relationship between UFPs and various co-pollutants daily, including during morning rush hour periods. This study found a moderate correlation among UFPs and black carbon, NO(x), NO2, and NO during hourly continuous measurements and rush hour periods, and a low level of correlation among UFPs and CO, O3, SO2, PM10, relative humidity, wind speed, and ambient temperature. This study indicates that co-pollutants should not be used as a surrogate to assess the human health risk from ultrafine particles exposure.

  6. Fine particle number and mass concentration measurements in urban Indian households.

    PubMed

    Mönkkönen, P; Pai, P; Maynard, A; Lehtinen, K E J; Hämeri, K; Rechkemmer, P; Ramachandran, G; Prasad, B; Kulmala, M

    2005-07-15

    Fine particle number concentration (D(p)>10 nm, cm(-3)), mass concentrations (approximation of PM(2.5), microg m(-3)) and indoor/outdoor number concentration ratio (I/O) measurements have been conducted for the first time in 11 urban households in India, 2002. The results indicate remarkable high indoor number and mass concentrations and I/O number concentration ratios caused by cooking. Besides cooking stoves that used liquefied petroleum gas (LPG) or kerosene as the main fuel, high indoor concentrations can be explained by poor ventilation systems. Particle number concentrations of more than 300,000 cm(-3) and mass concentrations of more than 1000 microg m(-3) were detected in some cases. When the number and mass concentrations during cooking times were statistically compared, a correlation coefficient r>0.50 was observed in 63% of the households. Some households used other fuels like wood and dung cakes along with the main fuel, but also other living activities influenced the concentrations. In some areas, outdoor combustion processes had a negative impact on indoor air quality. The maximum concentrations observed in most cases were due to indoor combustion sources. Reduction of exposure risk and health effects caused by poor indoor air in urban Indian households is possible by improving indoor ventilation and reducing penetration of outdoor particles.

  7. Field evaluation of vegetation and noise barriers for mitigation of near-freeway air pollution under variable wind conditions

    NASA Astrophysics Data System (ADS)

    Lee, Eon S.; Ranasinghe, Dilhara R.; Ahangar, Faraz Enayati; Amini, Seyedmorteza; Mara, Steven; Choi, Wonsik; Paulson, Suzanne; Zhu, Yifang

    2018-02-01

    Traffic-related air pollutants are a significant public health concern, particularly near freeways. Previous studies have suggested either soundwall or vegetation barriers might reduce the near-freeway air pollution. This study aims to investigate the effectiveness of a combination of both soundwall and vegetation barrier for reducing ultrafine particles (UFPs, diameter ≤ 100 nm) and PM2.5 (diameter ≤ 2.5 μm) concentrations. Concurrent data collection was carried out at both upwind and downwind fixed locations approximately 10-15 m away from the edge of two major freeways in California. This study observed that the reduction of UFP and PM2.5 was generally greater with the combination barrier than with either soundwall or vegetation alone. Since there were no non-barrier sites at the study locations, the reductions reported here are all in relative terms. The soundwall barrier was more effective for reducing PM2.5 (25-53%) than UFPs (0-5%), and was most effective (51-53% for PM2.5) when the wind speed ranged between 1 and 2 m/s. Under the same range of wind speed, the vegetation barrier had little effect (0-5%) on reducing PM2.5; but was effective at reducing UFP (up to 50%). For both types of roadside barrier, decreasing wind speed resulted in greater net reduction of UFPs (i.e., total number particle concentrations; inversely proportional). This trend was observed, however, only within specific particle size ranges (i.e., diameter < 20 nm for the soundwall barrier and 12-60 nm for the vegetation barrier). Out of these size ranges, the reduction of UFP concentration was proportional to increasing wind speed. Overall findings of this study support positive effects of soundwall and vegetation barriers for near-freeway air pollution mitigation.

  8. Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris, France).

    PubMed

    Paunescu, A-C; Attoui, M; Bouallala, S; Sunyer, J; Momas, I

    2017-07-01

    This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old children from the PARIS birth cohort. BC and UFP were continuously measured by portable devices (microAeth ® AE51 and DiSCmini ® ) for a minimum of 24 hours, while participating families simultaneously filled in a space-time-activities-budget questionnaire. BC exposure concentration was higher during trips (principally metro/train and bus), while UFP exposure concentration was higher during indoor activities (mainly eating at restaurants) and in trips. The most important UFP peaks were measured at home, especially during cooking. Home and school together accounted for much of the total exposure, 83.8% for BC and 85.3% for UFP. The contribution of transport to total exposure was 12.4% for BC and 9.7% for UFP, while extracurricular activities were responsible for 3.8% and 5% of the total exposure to BC and UFP, respectively. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Exposure to ultrafine particles and PM 2.5 in four Sydney transport modes

    NASA Astrophysics Data System (ADS)

    Knibbs, Luke D.; de Dear, Richard J.

    2010-08-01

    Concentrations of ultrafine (<0.1 μm) particles (UFPs) and PM 2.5 (<2.5 μm) were measured whilst commuting along a similar route by train, bus, ferry and automobile in Sydney, Australia. One trip on each transport mode was undertaken during both morning and evening peak hours throughout a working week, for a total of 40 trips. Analyses comprised one-way ANOVA to compare overall (i.e. all trips combined) geometric mean concentrations of both particle fractions measured across transport modes, and assessment of both the correlation between wind speed and individual trip means of UFPs and PM 2.5, and the correlation between the two particle fractions. Overall geometric mean concentrations of UFPs and PM 2.5 ranged from 2.8 (train) to 8.4 (bus) × 10 4 particles cm -3 and 22.6 (automobile) to 29.6 (bus) μg m -3, respectively, and a statistically significant difference ( p < 0.001) between modes was found for both particle fractions. Individual trip geometric mean concentrations were between 9.7 × 10 3 (train) and 2.2 × 10 5 (bus) particles cm -3 and 9.5 (train) to 78.7 (train) μg m -3. Estimated commuter exposures were variable, and the highest return trip mean PM 2.5 exposure occurred in the ferry mode, whilst the highest UFP exposure occurred during bus trips. The correlation between fractions was generally poor, and in keeping with the duality of particle mass and number emissions in vehicle-dominated urban areas. Wind speed was negatively correlated with, and a generally poor determinant of, UFP and PM 2.5 concentrations, suggesting a more significant role for other factors in determining commuter exposure.

  10. Commuter exposure to ultrafine particles in different urban locations, transportation modes and routes

    NASA Astrophysics Data System (ADS)

    Ragettli, Martina S.; Corradi, Elisabetta; Braun-Fahrländer, Charlotte; Schindler, Christian; de Nazelle, Audrey; Jerrett, Michael; Ducret-Stich, Regina E.; Künzli, Nino; Phuleria, Harish C.

    2013-10-01

    A better understanding of ultrafine particle (UFP) exposure in different urban transport microenvironments is important for epidemiological exposure assessments and for policy making. Three sub-studies were performed to characterize personal exposure to UFP concentration and average particle size distribution diameters in frequently traveled commuter microenvironments in the city of Basel, Switzerland. First, the spatial variation of sidewalk UFP exposures within urban areas and transport-specific microenvironments was explored. Second, exposure to UFP concentration and average particle size were quantified for five modes of transportation (walking, bicycle, bus, tram, car) during different times of the day and week, along the same route. Finally, the contribution of bicycle commuting along two different routes (along main roads, away from main roads) to total daily exposures was assessed by 24-h personal measurements. In general, smaller average particle sizes and higher UFP levels were measured at places and for travel modes in close proximity to traffic. Average trip UFP concentrations were higher in car (31,784 particles cm-³) and on bicycle (22,660 particles cm-³) compared to walking (19,481 particles cm-³) and public transportation (14,055-18,818 particles cm-³). Concentrations were highest for all travel modes during weekday morning rush hours, compared to other time periods. UFP concentration was lowest in bus, regardless of time period. Bicycle travel along main streets between home and work place (24 min on average) contributed 21% and 5% to total daily UFP exposure in winter and summer, respectively. Contribution of bicycle commutes to total daily UFP exposure could be reduced by half if main roads are avoided. Our results show the importance of considering commuter behavior and route choice in exposure assessment studies.

  11. Spatial variation of ultrafine particles and black carbon in two cities: results from a short-term measurement campaign.

    PubMed

    Klompmaker, Jochem O; Montagne, Denise R; Meliefste, Kees; Hoek, Gerard; Brunekreef, Bert

    2015-03-01

    Recently, short-term monitoring campaigns have been carried out to investigate the spatial variation of air pollutants within cities. Typically, such campaigns are based on short-term measurements at relatively large numbers of locations. It is largely unknown how well these studies capture the spatial variation of long term average concentrations. The aim of this study was to evaluate the within-site temporal and between-site spatial variation of the concentration of ultrafine particles (UFPs) and black carbon (BC) in a short-term monitoring campaign. In Amsterdam and Rotterdam (the Netherlands) measurements of number counts of particles larger than 10nm as a surrogate for UFP and BC were performed at 80 sites per city. Each site was measured in three different seasons of 2013 (winter, spring, summer). Sites were selected from busy urban streets, urban background, regional background and near highways, waterways and green areas, to obtain sufficient spatial contrast. Continuous measurements were performed for 30 min per site between 9 and 16 h to avoid traffic spikes of the rush hour. Concentrations were simultaneously measured at a reference site to correct for temporal variation. We calculated within- and between-site variance components reflecting temporal and spatial variations. Variance ratios were compared with previous campaigns with longer sampling durations per sample (24h to 14 days). The within-site variance was 2.17 and 2.44 times higher than the between-site variance for UFP and BC, respectively. In two previous studies based upon longer sampling duration much smaller variance ratios were found (0.31 and 0.09 for UFP and BC). Correction for temporal variation from a reference site was less effective for the short-term monitoring campaign compared to the campaigns with longer duration. Concentrations of BC and UFP were on average 1.6 and 1.5 times higher at urban street compared to urban background sites. No significant differences between the other

  12. Aircraft emission impacts in a neighborhood adjacent to a general aviation airport in southern California.

    PubMed

    Hu, Shishan; Fruin, Scott; Kozawa, Kathleen; Mara, Steve; Winer, Arthur M; Paulson, Suzanne E

    2009-11-01

    Real time air pollutant concentrations were measured downwind of Santa Monica Airport (SMA), using an electric vehicle mobile platform equipped with fast response instruments in spring and summer of 2008. SMA is a general aviation airport operated for private aircraft and corporate jets in Los Angeles County, California. An impact area of elevated ultrafine particle (UFP) concentrations was observed extending beyond 660 m downwind and 250 m perpendicular to the wind on the downwind side of SMA. Aircraft operations resulted in average UFP concentrations elevated by factors of 10 and 2.5 at 100 and 660 m downwind, respectively, over background levels. The long downwind impact distance (i.e., compared to nearby freeways at the same time of day) is likely primarily due to the large volumes of aircraft emissions containing higher initial concentrations of UFP than on-road vehicles. Aircraft did not appreciably elevate average levels of black carbon (BC), particle-bound polycyclic aromatic hydrocarbons (PB-PAH), although spikes in concentration of these pollutants were observed associated with jet takeoffs. Jet departures resulted in peak 60-s average concentrations of up to 2.2 x 10(6) cm(-3), 440 ng m(-3), and 30 microg m(-3) for UFP, PB-PAH, and BC, respectively, 100 m downwind of the takeoff area. These peak levels were elevated by factors of 440, 90, and 100 compared to background concentrations. Peak UFP concentrations were reasonably correlated (r(2) = 0.62) with fuel consumption rates associated with aircraft departures, estimated from aircraft weights and acceleration rates. UFP concentrations remained elevated for extended periods associated particularly with jet departures, but also with jet taxi and idle, and operations of propeller aircraft. UFP measured downwind of SMA had a median mode of about 11 nm (electric mobility diameter), which was about half of the 22 nm median mode associated with UFP from heavy duty diesel trucks. The observation of highly

  13. Measurement of Ultrafine Particles and Other Air Pollutants Emitted by Cooking Activities

    PubMed Central

    Zhang, Qunfang; Gangupomu, Roja H.; Ramirez, David; Zhu, Yifang

    2010-01-01

    Cooking emissions show a strong dependence on cooking styles and parameters. Measurements of the average ultrafine particle (UFP) concentration, PM2.5 and black carbon concentrations emitted by cooking activities ranged from 1.34 × 104 to 6.04 × 105 particles/cm3, 10.0 to 230.9 μg/m3 and 0.1 to 0.8 μg/m3, respectively. Lower UFP concentrations were observed during boiling, while higher levels were emitted during frying. The highest UFP concentrations were observed when using a gas stove at high temperature with the kitchen exhaust fan turned off. The observed UFP profiles were similar in the kitchen and in another room, with a lag of approximately 10 min. PMID:20617057

  14. Near roadway air pollution across a spatially extensive road and cycling network.

    PubMed

    Farrell, William; Weichenthal, Scott; Goldberg, Mark; Valois, Marie-France; Shekarrizfard, Maryam; Hatzopoulou, Marianne

    2016-05-01

    This study investigates the variability in near-road concentrations of ultra-fine particles (UFP). Our results are based on a mobile data collection campaign conducted in 2012 in Montreal, Canada using instrumented bicycles and covering approximately 475 km of unique roadways. The spatial extent of the data collected included a diverse array of roads and land use patterns. Average concentrations of UFP per roadway segment varied greatly across the study area (1411-192,340 particles/cm(3)) as well as across the different visits to the same segment. Mixed effects linear regression models were estimated for UFP (R(2) = 43.80%), incorporating a wide range of predictors including land-use, built environment, road characteristics, and meteorology. Temperature and wind speed had a large negative effect on near-road concentrations of UFP. Both the day of the week and time of day had a significant effect with Tuesdays and afternoon periods positively associated with UFP. Since UFP are largely associated with traffic emissions and considering the wide spatial extent of our data collection campaign, it was impossible to collect traffic volume data. For this purpose, we used simulated data for traffic volumes and speeds across the region and observed a positive effect for volumes and negative effect for speed. Finally, proximity to truck routes was also associated with higher UFP concentrations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Reduction of exposure to ultrafine particles by kitchen exhaust hoods: the effects of exhaust flow rates, particle size, and burner position.

    PubMed

    Rim, Donghyun; Wallace, Lance; Nabinger, Steven; Persily, Andrew

    2012-08-15

    Cooking stoves, both gas and electric, are one of the strongest and most common sources of ultrafine particles (UFP) in homes. UFP have been shown to be associated with adverse health effects such as DNA damage and respiratory and cardiovascular diseases. This study investigates the effectiveness of kitchen exhaust hoods in reducing indoor levels of UFP emitted from a gas stove and oven. Measurements in an unoccupied manufactured house monitored size-resolved UFP (2 nm to 100 nm) concentrations from the gas stove and oven while varying range hood flow rate and burner position. The air change rate in the building was measured continuously based on the decay of a tracer gas (sulfur hexafluoride, SF(6)). The results show that range hood flow rate and burner position (front vs. rear) can have strong effects on the reduction of indoor levels of UFP released from the stove and oven, subsequently reducing occupant exposure to UFP. Higher range hood flow rates are generally more effective for UFP reduction, though the reduction varies with particle diameter. The influence of the range hood exhaust is larger for the back burner than for the front burner. The number-weighted particle reductions for range hood flow rates varying between 100 m(3)/h and 680 m(3)/h range from 31% to 94% for the front burner, from 54% to 98% for the back burner, and from 39% to 96% for the oven. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Traffic and nucleation events as main sources of ultrafine particles in high-insolation developed world cities

    NASA Astrophysics Data System (ADS)

    Brines, M.; Dall'Osto, M.; Beddows, D. C. S.; Harrison, R. M.; Gómez-Moreno, F.; Núñez, L.; Artíñano, B.; Costabile, F.; Gobbi, G. P.; Salimi, F.; Morawska, L.; Sioutas, C.; Querol, X.

    2015-05-01

    Road traffic emissions are often considered the main source of ultrafine particles (UFP, diameter smaller than 100 nm) in urban environments. However, recent studies worldwide have shown that - in high-insolation urban regions at least - new particle formation events can also contribute to UFP. In order to quantify such events we systematically studied three cities located in predominantly sunny environments: Barcelona (Spain), Madrid (Spain) and Brisbane (Australia). Three long-term data sets (1-2 years) of fine and ultrafine particle number size distributions (measured by SMPS, Scanning Mobility Particle Sizer) were analysed. Compared to total particle number concentrations, aerosol size distributions offer far more information on the type, origin and atmospheric evolution of the particles. By applying k-means clustering analysis, we categorized the collected aerosol size distributions into three main categories: "Traffic" (prevailing 44-63% of the time), "Nucleation" (14-19%) and "Background pollution and Specific cases" (7-22%). Measurements from Rome (Italy) and Los Angeles (USA) were also included to complement the study. The daily variation of the average UFP concentrations for a typical nucleation day at each site revealed a similar pattern for all cities, with three distinct particle bursts. A morning and an evening spike reflected traffic rush hours, whereas a third one at midday showed nucleation events. The photochemically nucleated particles' burst lasted 1-4 h, reaching sizes of 30-40 nm. On average, the occurrence of particle size spectra dominated by nucleation events was 16% of the time, showing the importance of this process as a source of UFP in urban environments exposed to high solar radiation. Nucleation events lasting for 2 h or more occurred on 55% of the days, this extending to > 4 h in 28% of the days, demonstrating that atmospheric conditions in urban environments are not favourable to the growth of photochemically nucleated particles. In

  17. Comparison of two estimation methods for surface area concentration using number concentration and mass concentration of combustion-related ultrafine particles

    NASA Astrophysics Data System (ADS)

    Park, Ji Young; Raynor, Peter C.; Maynard, Andrew D.; Eberly, Lynn E.; Ramachandran, Gurumurthy

    Recent research has suggested that the adverse health effects caused by nanoparticles are associated with their surface area (SA) concentrations. In this study, SA was estimated in two ways using number and mass concentrations and compared with SA (SA meas) measured using a diffusion charger (DC). Aerosol measurements were made twice: once starting in October 2002 and again starting in December 2002 in Mysore, India in residences that used kerosene or liquefied petroleum gas (LPG) for cooking. Mass, number, and SA concentrations and size distributions by number were measured in each residence. The first estimation method (SA PSD) used the size distribution by number to estimate SA. The second method (SA INV) used a simple inversion scheme that incorporated number and mass concentrations while assuming a lognormal size distribution with a known geometrical standard deviation. SA PSD was, on average, 2.4 times greater (range = 1.6-3.4) than SA meas while SA INV was, on average, 6.0 times greater (range = 4.6-7.7) than SA meas. The logarithms of SA PSD and SA INV were found to be statistically significant predictors of the logarithm of SA meas. The study showed that particle number and mass concentration measurements can be used to estimate SA with a correction factor that ranges between 2 and 6.

  18. [Health effects of ambient ultrafine particles--the project UFIREG].

    PubMed

    Dostál, Miroslav; Pastorková, Anna; Lanzinger, Stefanie; Schneider, Alexandra; Bastian, Susanne; Senghaas, Monika; Erzen, Ziva; Novák, Jiří; Kolodnitska, Teťana; Šrám, Radim J; Peters, Annette

    2015-01-01

    The project "Ultrafine particles--an evidence based contribution to the development of regional and European environmental and health policy" (UFIREG) started in July 2011 and ended in December 2014. It was implemented through the Central Europe Programme and co-financed by the European Regional Development Fund. Five cities in four Central European countries participated in the study: Augsburg (Germany), Chernivtsi (Ukraine), Dresden (Germany), Ljubljana (Slovenia) and Prague (Czech Republic). The aim of the UFIREG project was to improve the knowledge base on possible health effects of ambient ultrafine particles (UFP) and to raise overall awareness of environmental and health care authorities and the population. Epidemiological studies in the frame of the UFIREG project have assessed the short-term effects of UFP on human mortality and morbidity, especially in relation to cardiovascular and respiratory diseases. Official statistics were used to determine the association between air pollution concentration and daily (cause-specific: respiratory and cardiovascular) hospital admissions and mortality. Associations of UFP levels and health effects were analysed for each city by use of Poisson regression models adjusting for a number of confounding factors. Results on morbidity and mortality effects of UFP were heterogeneous across the five European cities investigated. Overall, an increase in respiratory hospital admissions and mortality could be detected for increases in UFP concentrations. Results on cardiovascular health were less conclusive. Further multi-centre studies such as UFIREG are needed preferably investigating several years in order to produce powerful results.

  19. The Effect of Ultrafine Process on the Dissolution, Antibacterial Activity, and Cytotoxicity of Coptidis rhizoma

    PubMed Central

    Jiang, Zhen-Yu; Deng, Hai-Ying; Yu, Zhi-Jun; Ni, Jun-Yan; Kang, Si-He

    2016-01-01

    Background: The dosage of herb ultrafine particle (UFP) depended on the increased level of its dissolution, toxicity, and efficacy. Objective: The dissolution, antibacterial activity, and cytotoxicity of Coptidis rhizoma (CR) UFP were compared with those of traditional decoction (TD). Materials and Methods: The dissolution of berberine (BBR) of CR TD and UFP was determined by high-performance liquid chromatography. The antibacterial activity of CR extract was assayed by plate-hole diffusion and broth dilution method; the inhibitory effect of rat serums against bacteria growth was evaluated after orally given CR UFP or TD extract. The cytotoxicity of CR extract was evaluated by 3-(4,5-dimethylthiazol-2-Yl)-2,5-diphenyltetrazolium bromide assay. Results: The dissolution amount of BBR from CR UFP increased 6–8-folds in comparison to TD at 2 min, the accumulative amount of BBR in both UFP and TD group increased in a time-dependent manner. The minimal inhibitory concentrations and minimal bactericidal concentrations of CR UFP extract decreased to 1/2~1/4 of those of TD extract. The inhibitory effect of rat serums against bacteria growth decreased time-dependently, and no statistical difference was observed between two groups at each time point. The 50% cytotoxic concentrations of UFP extract increased 1.66~1.97 fold than those of TD. Conclusions: The antibacterial activity and cytotoxicity of CR UFP increased in a dissolution-effect manner in vitro, the increased level of cytotoxicity was lower than that of antibacterial activity, and the inhibitory effect of rat serums containing drugs of UFP group did not improve. SUMMARY Ultrafine grinding process caused a rapid increase of BBR dissolution from CR.The antibacterial activity and cytotoxicity of UFP extract in vitro increased in a dissolution-effect manner, but the cytotoxicity increased lower than the antibacterial activity.The antibacterial activity of rat serums of UFP group did not improve in comparison to that

  20. Comparison between ultrafine and fine particulate matter collected in Lebanon: Chemical characterization, in vitro cytotoxic effects and metabolizing enzymes gene expression in human bronchial epithelial cells.

    PubMed

    Borgie, Mireille; Dagher, Zeina; Ledoux, Frédéric; Verdin, Anthony; Cazier, Fabrice; Martin, Perrine; Hachimi, Adam; Shirali, Pirouz; Greige-Gerges, Hélène; Courcot, Dominique

    2015-10-01

    During the last few years, the induction of toxicological mechanisms by atmospheric ultrafine particles (UFP) has become one of the most studied topics in toxicology and a subject of huge debates. Fine particles (FP) and UFP collected at urban and rural sites in Lebanon were studied for their chemical composition and toxicological effects. UFP were found more enriched in trace elements, secondary inorganic ions, total carbon and organic compounds than FP. For toxicological analysis, BEAS-2B cells were exposed for 24, 48 and 72 h to increasing concentrations of FP, water-UFP suspension (UFPw) and UFP organic extract (UFPorg). Our findings showed that UFP caused earlier alterations of mitochondrial metabolism and membrane integrity from the lowest concentrations. Moreover, a significant induction of CYP1A1, CYP1B1 and AhRR genes expression was showed after cells exposure to UFPorg and to a lesser extent to UFPw and FP samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Solar concentration properties of flat fresnel lenses with large F-numbers

    NASA Technical Reports Server (NTRS)

    Cosby, R. M.

    1978-01-01

    The solar concentration performances of flat, line-focusing sun-tracking Fresnel lenses with selected f-numbers between 0.9 and 2.0 were analyzed. Lens transmittance was found to have a weak dependence on f-number, with a 2% increase occuring as the f-number is increased from 0.9 to 2.0. The geometric concentration ratio for perfectly tracking lenses peaked for an f-number near 1.35. Intensity profiles were more uniform over the image extent for large f-number lenses when compared to the f/0.9 lens results. Substantial decreases in geometri concentration ratios were observed for transverse tracking errors equal to or below 1 degree for all f-number lenses. With respect to tracking errors, the solar performance is optimum for f-numbers between 1.25 and 1.5.

  2. Estimation of surface area concentration of workplace incidental nanoparticles based on number and mass concentrations

    NASA Astrophysics Data System (ADS)

    Park, J. Y.; Ramachandran, G.; Raynor, P. C.; Kim, S. W.

    2011-10-01

    Surface area was estimated by three different methods using number and/or mass concentrations obtained from either two or three instruments that are commonly used in the field. The estimated surface area concentrations were compared with reference surface area concentrations (SAREF) calculated from the particle size distributions obtained from a scanning mobility particle sizer and an optical particle counter (OPC). The first estimation method (SAPSD) used particle size distribution measured by a condensation particle counter (CPC) and an OPC. The second method (SAINV1) used an inversion routine based on PM1.0, PM2.5, and number concentrations to reconstruct assumed lognormal size distributions by minimizing the difference between measurements and calculated values. The third method (SAINV2) utilized a simpler inversion method that used PM1.0 and number concentrations to construct a lognormal size distribution with an assumed value of geometric standard deviation. All estimated surface area concentrations were calculated from the reconstructed size distributions. These methods were evaluated using particle measurements obtained in a restaurant, an aluminum die-casting factory, and a diesel engine laboratory. SAPSD was 0.7-1.8 times higher and SAINV1 and SAINV2 were 2.2-8 times higher than SAREF in the restaurant and diesel engine laboratory. In the die casting facility, all estimated surface area concentrations were lower than SAREF. However, the estimated surface area concentration using all three methods had qualitatively similar exposure trends and rankings to those using SAREF within a workplace. This study suggests that surface area concentration estimation based on particle size distribution (SAPSD) is a more accurate and convenient method to estimate surface area concentrations than estimation methods using inversion routines and may be feasible to use for classifying exposure groups and identifying exposure trends.

  3. Relationships of outdoor and indoor ultrafine particles at residences downwind of a major international border crossing in Buffalo, NY.

    PubMed

    McAuley, T R; Fisher, R; Zhou, X; Jaques, P A; Ferro, A R

    2010-08-01

    During winter 2006, indoor and outdoor ultrafine particle (UFP) size distribution measurements for particles with diameters from 5.6 to 165 nm were taken at five homes in a neighborhood directly adjacent to the Peace Bridge Complex (PBC), a major international border crossing connecting Buffalo, New York to Fort Erie, Ontario. Monitoring with 1-s time resolution was conducted for several hours at each home. Participants were instructed to keep all external windows and doors closed and to refrain from cooking, smoking, or other activity that may result in elevating the indoor UFP number concentration. Although the construction and age for the homes were similar, indoor-to-outdoor comparisons indicate that particle infiltration rates varied substantially. Overall, particle concentrations indoors were lower and less variable than particle concentrations outdoors, with average indoor-outdoor ratios ranging from 0.1 to 0.5 (mean 0.34) for particles between 5.6 and 165 nm in diameter. With no indoor sources, the average indoor-outdoor ratios were lowest (0.2) for 20-nm particles, higher (0.3) for particles <10 nm, and highest (0.5) for particles 70-165 nm. This study provides insight into the penetration of UFP into homes and the resulting change in particle size distributions as particles move indoors near a major diesel traffic source. Although people spend most of their time in their homes, exposure estimates for epidemiological studies are generally determined using ambient concentrations. The findings of this study will contribute to improved size-resolved UFP exposure estimates for near roadway exposure assessments and epidemiological studies.

  4. Ultrafine particle emissions from essential-oil-based mosquito repellent products.

    PubMed

    Liu, J; Fung, D; Jiang, J; Zhu, Y

    2014-06-01

    Ultrafine particle (UFP) emissions from three essential-oil-based mosquito repellent products (lemon eucalyptus (LE), natural insects (NI), and bite shield (BS)) were tested in a 386 l chamber at a high air exchange rate of 24/h with filtered laboratory air. Total particle number concentration and size distribution were monitored by a condensation particle counter and a scanning mobility particle sizer, respectively. UFPs were emitted from all three products under indoor relevant ozone concentrations (~ 17 ppb). LE showed a nucleation burst followed by a relatively stable and continuous emission while the other two products (NI and BS) showed episodic emissions. The estimated maximum particle emission rate varied from 5.4 × 10(9) to 1.2 × 10(12) particles/min and was directly related to the dose of mosquito repellent used. These rates are comparable to those due to other indoor activities such as cooking and printing. The emission duration for LE lasted for 8-78 min depending on the dose applied while the emission duration for NI and BS lasted for 2-3 h. Certain essential-oil-based mosquito repellents can produce high concentrations of UFPs when applied, even at low ozone levels. Household and personal care products that contain essential oil may need to be tested at indoor relevant ozone levels to determine their potential to increase personal UFP exposures. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Comparison of Mutagenic Activities of Various Ultra-Fine Particles.

    PubMed

    Park, Chang Gyun; Cho, Hyun Ki; Shin, Han Jae; Park, Ki Hong; Lim, Heung Bin

    2018-04-01

    Air pollution is increasing, along with consumption of fossil fuels such as coal and diesel gas. Air pollutants are known to be a major cause of respiratory-related illness and death, however, there are few reports on the genotoxic characterization of diverse air pollutants in Korea. In this study, we investigated the mutagenic activity of various particles such as diesel exhaust particles (DEP), combustion of rice straw (RSC), pine stem (PSC), and coal (CC), tunnel dust (TD), and road side dust (RD). Ultra-fine particles (UFPs) were collected by the glass fiber filter pad. Then, we performed a chemical analysis to see each of the component features of each particulate matter. The mutagenicity of various UFPs was determined by the Ames test with four Salmonella typhimurium strains with or without metabolic activation. The optimal concentrations of UFPs were selected based on result of a concentration decision test. Moreover, in order to compare relative mutagenicity among UFPs, we selected and tested DEP as mutation reference. DEP, RSC, and PSC induced concentration-dependent increases in revertant colony numbers with TA98, TA100, and TA1537 strains in the absence and presence of metabolic activation. DEP showed the highest specific activity among the particulate matters. In this study, we conclude that DEP, RSC, PSC, and TD displayed varying degrees of mutagenicity, and these results suggest that the mutagenicity of these air pollutants is associated with the presence of polycyclic aromatic hydrocarbons (PAHs) in these particulate matters.

  6. A case study of exposure to ultrafine particles from secondhand tobacco smoke in an automobile.

    PubMed

    Liu, S; Zhu, Y

    2010-10-01

    Secondhand tobacco smoke (SHS) in enclosed spaces is a major source of potentially harmful airborne particles. To quantify exposure to ultrafine particles (UFP) because of SHS and to investigate the interaction between pollutants from SHS and vehicular emissions, number concentration and size distribution of UFP and other air pollutants (CO, CO(2) , and PM(2.5)) were measured inside a moving vehicle under five different ventilation conditions. A major interstate freeway with a speed limit of 60 mph and an urban roadway with a speed limit of 30 mph were selected to represent typical urban routes. In a typical 30-min commute on urban roadways, the SHS of one cigarette exposed passengers to approximately 10 times the UFP and 120 times the PM(2.5) of ambient air. The most effective solution to protect passengers from SHS exposure is to abstain from smoking in the vehicle. Opening a window is an effective method for decreasing pollutant exposures on most urban roadways. However, under road conditions with high UFP concentrations, such as tunnels or busy freeways with high proportion of heavy-duty diesel trucks (such as the 710 Freeway in Los Angeles, CA, USA), opening a window is not a viable method to reduce UFPs. Time budget studies show that Americans spend, on average, more than 60 min each day in enclosed vehicles. Smoking inside vehicles can expose the driver and other passengers to high levels of pollutants. Thus, an understanding of the variations and interactions of secondhand tobacco smoke (SHS) and vehicular emissions under realistic driving conditions is necessary. Results of this study indicated that high ventilation rates can effectively dilute ultrafine particles (UFP) inside moving vehicles on urban routes. However, driving with open windows and an increased air exchange rate (AER) are not recommended on tunnels and heavily travelled freeways.

  7. Contribution of various microenvironments to the daily personal exposure to ultrafine particles: Personal monitoring coupled with GPS tracking

    NASA Astrophysics Data System (ADS)

    Bekö, Gabriel; Kjeldsen, Birthe Uldahl; Olsen, Yulia; Schipperijn, Jasper; Wierzbicka, Aneta; Karottki, Dorina Gabriela; Toftum, Jørn; Loft, Steffen; Clausen, Geo

    2015-06-01

    Exposure to ultrafine particles (UFP) may have adverse health effects. Central monitoring stations do not represent the personal exposure to UFP accurately. Few studies have previously focused on personal exposure to UFP. Sixty non-smoking residents living in Copenhagen, Denmark were asked to carry a backpack equipped with a portable monitor, continuously recording particle number concentrations (PN), in order to measure the real-time individual exposure over a period of ˜48 h. A GPS logger was carried along with the particle monitor and allowed us to estimate the contribution of UFP exposure occurring in various microenvironments (residence, during active and passive transport, other indoor and outdoor environments) to the total daily exposure. On average, the fractional contribution of each microenvironment to the daily integrated personal exposure roughly corresponded to the fractions of the day the subjects spent in each microenvironment. The home environment accounted for 50% of the daily personal exposure. Indoor environments other than home or vehicles contributed with ˜40%. The highest median UFP concentration was obtained during passive transport (vehicles). However, being in transit or outdoors contributed 5% or less to the daily exposure. Additionally, the subjects recorded in a diary the periods when they were at home. With this approach, 66% of the total daily exposure was attributable to the home environment. The subjects spent 28% more time at home according to the diary, compared to the GPS. These results may indicate limitations of using diaries, but also possible inaccuracy and miss-classification in the GPS data.

  8. The occurrence of ultrafine particles in the specific environment of children.

    PubMed

    Burtscher, Heinz; Schüepp, Karen

    2012-06-01

    Interest in ultrafine particles (UFP) has been increasing due to their specific physico-chemical characteristics. Ultrafine particles are those with an aerodynamic diameter of <0.1 μm and are also commonly know as nanoparticles (0.1 μm = 100 nm). Due to their small size UFP contribute mostly to particle number concentrations and are therefore underestimated in actual pollution measurements, which commonly measure mass concentration. Children represent the most vulnerable group in regard to particulate exposure due to their developing status and different exposures compared to adults. This review discusses the sources of ultrafine particles as well as the specific exposures of children highlighting the importance and uniqueness of this age group. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Effect of cabin ventilation rate on ultrafine particle exposure inside automobiles.

    PubMed

    Knibbs, Luke D; de Dear, Richard J; Morawska, Lidia

    2010-05-01

    We alternately measured on-road and in-vehicle ultrafine (<100 nm) particle (UFP) concentration for 5 passenger vehicles that comprised an age range of 18 years. A range of cabin ventilation settings were assessed during 301 trips through a 4 km road tunnel in Sydney, Australia. Outdoor air flow (ventilation) rates under these settings were quantified on open roads using tracer gas techniques. Significant variability in tunnel trip average median in-cabin/on-road (I/O) UFP ratios was observed (0.08 to approximately 1.0). Based on data spanning all test automobiles and ventilation settings, a positive linear relationship was found between outdoor air flow rate and I/O ratio, with the former accounting for a substantial proportion of variation in the latter (R(2) = 0.81). UFP concentrations recorded in-cabin during tunnel travel were significantly higher than those reported by comparable studies performed on open roadways. A simple mathematical model afforded the ability to predict tunnel trip average in-cabin UFP concentrations with good accuracy. Our data indicate that under certain conditions, in-cabin UFP exposures incurred during tunnel travel may contribute significantly to daily exposure. The UFP exposure of automobile occupants appears strongly related to their choice of ventilation setting and vehicle.

  10. What controls the low ice number concentration in the upper troposphere?

    NASA Astrophysics Data System (ADS)

    Zhou, Cheng; Penner, Joyce E.; Lin, Guangxing; Liu, Xiaohong; Wang, Minghuai

    2016-10-01

    Cirrus clouds in the tropical tropopause play a key role in regulating the moisture entering the stratosphere through their dehydrating effect. Low ice number concentrations ( < 200 L-1) and high supersaturations (150-160 %) have been observed in these clouds. Different mechanisms have been proposed to explain these low ice number concentrations, including the inhibition of homogeneous freezing by the deposition of water vapour onto pre-existing ice crystals, heterogeneous ice formation on glassy organic aerosol ice nuclei (IN), and limiting the formation of ice number from high-frequency gravity waves. In this study, we examined the effect from three different representations of updraft velocities, the effect from pre-existing ice crystals, the effect from different water vapour deposition coefficients (α = 0.1 or 1), and the effect of 0.1 % of the total secondary organic aerosol (SOA) particles acting as IN. Model-simulated ice crystal numbers are compared against an aircraft observational dataset.Including the effect from water vapour deposition on pre-existing ice particles can effectively reduce simulated in-cloud ice number concentrations for all model setups. A larger water vapour deposition coefficient (α = 1) can also efficiently reduce ice number concentrations at temperatures below 205 K, but less so at higher temperatures. SOA acting as IN is most effective at reducing ice number concentrations when the effective updraft velocities are moderate ( ˜ 0.05-0.2 m s-1). However, the effects of including SOA as IN and using (α = 1) are diminished when the effect from pre-existing ice is included.When a grid-resolved large-scale updraft velocity ( < 0.1 m s-1) is used, the ice nucleation parameterization with homogeneous freezing only or with both homogeneous freezing and heterogeneous nucleation is able to generate low ice number concentrations in good agreement with observations for temperatures below 205 K as long as the pre-existing ice effect is

  11. What controls the low ice number concentration in the upper troposphere?

    NASA Astrophysics Data System (ADS)

    Zhou, C.; Penner, J. E.; Lin, G.; Liu, X.; Wang, M.

    2015-12-01

    Cirrus clouds in the tropical tropopause play a key role in regulating the moisture entering the stratosphere through their dehydrating effect. Low ice number concentrations (< 200 L-1) and high supersaturations (150-160 %) have been observed in these clouds. Different mechanisms have been proposed to explain these low ice number concentrations, including the inhibition of homogeneous freezing by the deposition of water vapour onto pre-existing ice crystals, heterogeneous ice formation on glassy organic aerosol ice nuclei (IN), and limiting the formation of ice number from high frequency gravity waves. In this study, we examined the effect from three different representations of updraft velocities, the effect from pre-existing ice crystals, the effect from different water vapour deposition coefficients (α = 0.1 or 1), and the effect of 0.1 % of the total secondary organic aerosol (SOA) particles acting as IN. Model simulated ice crystal numbers are compared against an aircraft observational dataset. Including the effect from water vapour deposition on pre-existing ice particles can effectively reduce simulated in-cloud ice number concentrations for all model set-ups. A larger water vapour deposition coefficient (α = 1) can also efficiently reduce ice number concentrations at temperatures below 205 K but less so at higher temperatures. SOA acting as IN are most effective at reducing ice number concentrations when the effective updraft velocities are moderate (∼ 0.05-0.2 m s-1). However, the effects of including SOA as IN and using (α = 1) are diminished when the effect from pre-existing ice is included. When a grid resolved large-scale updraft velocity (< 0.1 m s-1) is used, the ice nucleation parameterization with homogeneous freezing only or with both homogeneous freezing and heterogeneous nucleation is able to generate low ice number concentrations in good agreement with observations for temperatures below 205 K as long as the pre-existing ice effect is

  12. Assessing and reducing fine and ultrafine particles inside Los Angeles taxis

    NASA Astrophysics Data System (ADS)

    Yu, Nu; Shu, Shi; Lin, Yan; Zhu, Yifang

    2018-05-01

    Taxi drivers and passengers are exposed to high levels of traffic-related air pollutants, but their exposures to fine (PM2.5) and ultrafine particles (UFPs) and related mitigation strategies are rarely explored. In this study, UFP and PM2.5 concentrations were monitored concurrently inside and outside of 22 taxis under different ventilation and mitigation conditions. Under realistic working conditions (no mitigation; NM), the average UFP and PM2.5 levels inside taxis were 1.46 × 104 particles/cm3 and 26 μg/m3, respectively. When the taxi ventilation was set to outside air mode and the windows kept closed, in-cabin UFP and PM2.5 concentrations are significantly associated with on-road concentrations, driving speed, and cabin air filter usage. The average in-cabin to on-roadway (I/O) ratios for UFP and PM2.5 were reduced from 0.60 to 0.75 under NM, to 0.47 and 0.52 under the most stringent mitigation strategy of keeping the windows closed and operating a high efficiency cabin air filter (WC + HECA). Among all tested taxi models, Toyota Prius exhibited the lowest UFP and PM2.5 I/O ratios under WC + HECA. Switching cabin air filters from the originally equipped manufacturer filter (OEM) to a HECA filter reduced the UFP and PM2.5 I/O ratios most effectively in Toyota Prius taxis as well.

  13. Chemical, dimensional and morphological ultrafine particle characterization from a waste-to-energy plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buonanno, Giorgio, E-mail: buonanno@unicas.it; Stabile, Luca; Avino, Pasquale

    2011-11-15

    Highlights: > Particle size distributions and total concentrations measurement at the stack and before the fabric filter of an incinerator. > Chemical characterization of UFPs in terms of heavy metal concentration through a nuclear method. > Mineralogical investigation through a Transmission Electron Microscope equipped with an Energy Dispersive Spectrometer. > Heavy metal concentrations on UFPs as function of the boiling temperature. > Different mineralogical and morphological composition amongst samples collected before the fabric filter and at the stack. - Abstract: Waste combustion processes are responsible of particles and gaseous emissions. Referring to the particle emission, in the last years specificmore » attention was paid to ultrafine particles (UFPs, diameter less than 0.1 {mu}m), mainly emitted by combustion processes. In fact, recent findings of toxicological and epidemiological studies indicate that fine and ultrafine particles could represent a risk for health and environment. Therefore, it is necessary to quantify particle emissions from incinerators also to perform an exposure assessment for the human populations living in their surrounding areas. To these purposes, in the present work an experimental campaign aimed to monitor UFPs was carried out at the incineration plant in San Vittore del Lazio (Italy). Particle size distributions and total concentrations were measured both at the stack and before the fabric filter inlet in order to evaluate the removal efficiency of the filter in terms of UFPs. A chemical characterization of UFPs in terms of heavy metal concentration was performed through a nuclear method, i.e. Instrumental Neutron Activation Analysis (INAA), as well as a mineralogical investigation was carried out through a Transmission Electron Microscope (TEM) equipped with an Energy Dispersive Spectrometer (EDS) in order to evaluate shape, crystalline state and mineral compound of sampled particles. Maximum values of 2.7 x 10{sup 7} part

  14. Relationships among particle number, surface area, and respirable mass concentrations in automotive engine manufacturing.

    PubMed

    Heitbrink, William A; Evans, Douglas E; Ku, Bon Ki; Maynard, Andrew D; Slavin, Thomas J; Peters, Thomas M

    2009-01-01

    This study investigated the relationships between particle number, surface area, and respirable mass concentration measured simultaneously in a foundry and an automotive engine machining and assembly center. Aerosol concentrations were measured throughout each plant with a condensation particle counter for number concentration, a diffusion charger for active surface area concentration, and an optical particle counter for respirable mass concentration. At selected locations, particle size distributions were characterized with the optical particle counter and an electrical low pressure impactor. Statistical analyses showed that active surface area concentration was correlated with ultrafine particle number concentration and weakly correlated with respirable mass concentration. Correlation between number and active surface area concentration was stronger during winter (R2 = 0.6 for both plants) than in the summer (R2 = 0.38 and 0.36 for the foundry and engine plant respectively). The stronger correlation in winter was attributed to use of direct-fire gas fired heaters that produced substantial numbers of ultrafine particles with a modal diameter between 0.007 and 0.023 mu m. These correlations support findings obtained through theoretical analysis. Such analysis predicts that active surface area increasingly underestimates geometric surface area with increasing particle size, particularly for particles larger than 100 nm. Thus, a stronger correlation between particle number concentration and active surface area concentration is expected in the presence of high concentrations of ultrafine particles. In general, active surface area concentration may be a concentration metric that is distinct from particle number concentration and respirable mass concentration. For future health effects or toxicological studies involving nano-materials or ultrafine aerosols, this finding needs to be considered, as exposure metrics may influence data interpretation.

  15. Long-term cloud condensation nuclei number concentration, particle number size distribution and chemical composition measurements at regionally representative observatories

    NASA Astrophysics Data System (ADS)

    Schmale, Julia; Henning, Silvia; Decesari, Stefano; Henzing, Bas; Keskinen, Helmi; Sellegri, Karine; Ovadnevaite, Jurgita; Pöhlker, Mira L.; Brito, Joel; Bougiatioti, Aikaterini; Kristensson, Adam; Kalivitis, Nikos; Stavroulas, Iasonas; Carbone, Samara; Jefferson, Anne; Park, Minsu; Schlag, Patrick; Iwamoto, Yoko; Aalto, Pasi; Äijälä, Mikko; Bukowiecki, Nicolas; Ehn, Mikael; Frank, Göran; Fröhlich, Roman; Frumau, Arnoud; Herrmann, Erik; Herrmann, Hartmut; Holzinger, Rupert; Kos, Gerard; Kulmala, Markku; Mihalopoulos, Nikolaos; Nenes, Athanasios; O'Dowd, Colin; Petäjä, Tuukka; Picard, David; Pöhlker, Christopher; Pöschl, Ulrich; Poulain, Laurent; Prévôt, André Stephan Henry; Swietlicki, Erik; Andreae, Meinrat O.; Artaxo, Paulo; Wiedensohler, Alfred; Ogren, John; Matsuki, Atsushi; Yum, Seong Soo; Stratmann, Frank; Baltensperger, Urs; Gysel, Martin

    2018-02-01

    Aerosol-cloud interactions (ACI) constitute the single largest uncertainty in anthropogenic radiative forcing. To reduce the uncertainties and gain more confidence in the simulation of ACI, models need to be evaluated against observations, in particular against measurements of cloud condensation nuclei (CCN). Here we present a data set - ready to be used for model validation - of long-term observations of CCN number concentrations, particle number size distributions and chemical composition from 12 sites on 3 continents. Studied environments include coastal background, rural background, alpine sites, remote forests and an urban surrounding. Expectedly, CCN characteristics are highly variable across site categories. However, they also vary within them, most strongly in the coastal background group, where CCN number concentrations can vary by up to a factor of 30 within one season. In terms of particle activation behaviour, most continental stations exhibit very similar activation ratios (relative to particles > 20 nm) across the range of 0.1 to 1.0 % supersaturation. At the coastal sites the transition from particles being CCN inactive to becoming CCN active occurs over a wider range of the supersaturation spectrum. Several stations show strong seasonal cycles of CCN number concentrations and particle number size distributions, e.g. at Barrow (Arctic haze in spring), at the alpine stations (stronger influence of polluted boundary layer air masses in summer), the rain forest (wet and dry season) or Finokalia (wildfire influence in autumn). The rural background and urban sites exhibit relatively little variability throughout the year, while short-term variability can be high especially at the urban site. The average hygroscopicity parameter, κ, calculated from the chemical composition of submicron particles was highest at the coastal site of Mace Head (0.6) and lowest at the rain forest station ATTO (0.2-0.3). We performed closure studies based on κ

  16. ARM Evaluation Product : Droplet Number Concentration Value-Added Product

    DOE Data Explorer

    Riihimaki, Laura

    2014-05-15

    Cloud droplet number concentration is an important factor in understanding aerosol-cloud interactions. As aerosol concentration increases, it is expected that droplet number concentration, Nd, will increase and droplet size decrease, for a given liquid water path (Twomey 1977), which will greatly affect cloud albedo as smaller droplets reflect more shortwave radiation. However, the magnitude and variability of these processes under different environmental conditions is still uncertain. McComiskey et al. (2009) have implemented a method, based on Boers and Mitchell (1994), for calculating Nd from ground-based remote sensing measurements of optical depth and liquid water path. They show that the magnitude of the aerosol-cloud interactions (ACI) varies with a range of factors, including the relative value of the cloud liquid water path (LWP), the aerosol size distribution, and the cloud updraft velocity. Estimates of Nd under a range of cloud types and conditions and at a variety of sites are needed to further quantify the impacts of aerosol cloud interactions.

  17. Human peripheral blood mononuclear cells (PBMCs) from smokers release higher levels of IL-1-like cytokines after exposure to combustion-generated ultrafine particles.

    PubMed

    De Falco, Gianluigi; Terlizzi, Michela; Sirignano, Mariano; Commodo, Mario; D'Anna, Andrea; Aquino, Rita P; Pinto, Aldo; Sorrentino, Rosalinda

    2017-02-22

    Ultrafine particles (UFP) generated by combustion processes are often associated with adverse health effects. However, little is known about the inflammatory processes generated by UFP that may underlie their toxicological activity. Murine macrophages (J774.1 cells) and human peripheral blood mononuclear cells (PBMCs) were used to evaluate the molecular mechanism underlying the pro-inflammatory activity of UFP. The addition of soot particles to J774.1 cells induced a concentration-dependent release of IL-1α, IL-1β and IL-33 This effect was not associated with cell death and, in contrast to literature, was pronounced at very low concentrations (5-100 pg/ml). Similarly, UFP induced the release of IL-1α, IL-18 and IL-33 by PBMCs. However, this effect was solely observed in PBMCs obtained from smokers, as the PBMCs from non-smokers instead released higher levels of IL-10. The release of these cytokines after UFP exposure was caspase-1- and NLRP3 inflammasome-dependent in PBMCs from healthy smokers, whereas IL-1α release was calpain-dependent. These results show that UFP at very low concentrations are able to give rise to an inflammatory process that is responsible for IL-1α, IL-18 and IL-33 release, which is pronounced in PBMCs from smokers, confirming that these individuals are especially susceptible to inflammatory-based airway diseases once exposed to air pollution.

  18. Analysis of the chemical composition of ultrafine particles from two domestic solid biomass fired room heaters under simulated real-world use

    NASA Astrophysics Data System (ADS)

    Ozgen, Senem; Becagli, Silvia; Bernardoni, Vera; Caserini, Stefano; Caruso, Donatella; Corbella, Lorenza; Dell'Acqua, Manuela; Fermo, Paola; Gonzalez, Raquel; Lonati, Giovanni; Signorini, Stefano; Tardivo, Ruggero; Tosi, Elisa; Valli, Gianluigi; Vecchi, Roberta; Marinovich, Marina

    2017-02-01

    Two common types of wood (beech and fir) were burned in commercial pellet (11.1 kW) and wood (8.2 kW) stoves following a combustion cycle simulating the behavior of a real-world user. Ultrafine particulate matter (UFP, dp < 100 nm) was sampled with three parallel multistage impactors and analyzed for metals, main water soluble ions, anhydrosugars, total carbon, and PAH content. The measurement of the number concentration and size distribution was also performed by a fourth multistage impactor. UFP mass emission factors averaged to 424 mg/kgfuel for all the tested stove and wood type (fir, beech) combinations except for beech log burning in the wood stove (838 mg/kgfuel). Compositional differences were observed for pellets and wood UFP samples, where high TC levels characterize the wood log combustion and potassium salts are dominant in every pellet sample. Crucial aspects determining the UFP composition in the wood stove experiments are critical situations in terms of available oxygen (a lack or an excess of combustion air) and high temperatures. Whereas for the automatically controlled pellets stove local situations (e.g., hindered air-fuel mixing due to heaps of pellets on the burner pot) determine the emission levels and composition. Wood samples contain more potentially carcinogenic PAHs with respect to pellets samples. Some diagnostic ratios related to PAH isomers and anhydrosugars compiled from experimental UFP data in the present study and compared to literature values proposed for the emission source discrimination for atmospheric aerosol, extend the evaluation usually limited to higher particle size fractions also to UFP.

  19. Indoor/outdoor relationships and mass closure of quasi-ultrafine, accumulation and coarse particles in Barcelona schools

    NASA Astrophysics Data System (ADS)

    Viana, M.; Rivas, I.; Querol, X.; Alastuey, A.; Sunyer, J.; Álvarez-Pedrerol, M.; Bouso, L.; Sioutas, C.

    2014-05-01

    The mass concentration, chemical composition and sources of quasi-ultrafine (quasi-UFP, PM0.25), accumulation (PM0.25-2.5) and coarse mode (PM2.5-10) particles were determined in indoor and outdoor air at 39 schools in Barcelona (Spain). Quasi-UFP mass concentrations measured (25.6 μg m-3 outdoors, 23.4 μg m-3 indoors) are significantly higher than those reported in other studies, and characterised by higher carbonaceous and mineral matter contents and a lower proportion of secondary inorganic ions. Results suggest that quasi-UFPs in Barcelona are affected by local sources in the schools, mainly human activity (e.g. organic material from textiles, etc., contributing 23-46% to total quasi-UFP mass) and playgrounds (in the form of mineral matter, contributing about 9% to the quasi-UFP mass). The particle size distribution patterns of toxicologically relevant metals and major aerosol components was characterised, displaying two modes for most elements and components, and one mode for inorganic salts (ammonium nitrate and sulfate) and elemental carbon (EC). Regarding metals, Ni and Cr were partitioned mainly in quasi-UFPs and could thus be of interest for epidemiological studies, given their high redox properties. Exposure of children to quasi-UFP mass and chemical species was assessed by comparing the concentrations measured at urban background and traffic areas schools. Finally, three main indoor sources across all size fractions were identified by assessing indoor / outdoor ratios (I / O) of PM species used as their tracers: human activity (organic material), cleaning products, paints and plastics (Cl- source), and a metallic mixed source (comprising combinations of Cu, Zn, Co, Cd, Pb, As, V and Cr). Our results support the need to enforce targeted legislation to determine a minimum "safe" distance between major roads and newly built schools to reduce exposure to traffic-derived metals in quasi-UFPs.

  20. Ultrafine particle exposures while walking, cycling, and driving along an urban residential roadway

    NASA Astrophysics Data System (ADS)

    Quiros, David C.; Lee, Eon S.; Wang, Rui; Zhu, Yifang

    2013-07-01

    Elevated concentrations of ultrafine particles (UFPs, <0.1 μm), which have been linked to adverse health effects, are commonly found along roadways. This study reports UFP and PM2.5 concentrations and respiratory exposures among four transportation modes on an urban residential street in Santa Monica, California while walking, cycling, and driving with windows open and windows closed (with air recirculation on). Repeated measurements were made for nine days during morning (7:30-9:30), afternoon (12:30-14:30), and evening (17:00-19:00) periods. Median UFP concentrations ranged 1-3 × 104 particles cm-3, were 70% lower in afternoon or evening periods compared to the morning, and were 60% lower when driving with windows closed than open. Median PM2.5 ranged 2-15 μg m-3, well below the annual National Ambient Air Quality standard of 15 μg m-3. Respiratory UFP exposure (particles inhaled trip-1) was ˜2 times higher while driving with windows open, ˜15 times higher when cycling, and ˜30 times higher walking, than driving with windows closed. During one evening session with perpendicular rather than parallel wind conditions, absolute UFP concentration was 80% higher, suggesting influence of off-roadway sources. Under parallel wind conditions, a parameter called emissions-weighted traffic volume, used to account for higher and lower emitting vehicles, was correlated with beach-site-subtracted UFP using second-order polynomial model (R2 = 0.61). Based on this model, an 83% on-roadway UFP reduction could be achieved by (1) requiring all trucks to meet California 2007 model-year engine standards, (2) reducing light-duty vehicle flows by 25%, and (3) replacing high-emitting light-duty vehicles (pre 1978) with newer 2010 fleet-average vehicles.

  1. Effects of exposure to ambient ultrafine particles on respiratory health and systemic inflammation in children.

    PubMed

    Clifford, Sam; Mazaheri, Mandana; Salimi, Farhad; Ezz, Wafaa Nabil; Yeganeh, Bijan; Low-Choy, Samantha; Walker, Katy; Mengersen, Kerrie; Marks, Guy B; Morawska, Lidia

    2018-05-01

    It is known that ultrafine particles (UFP, particles smaller than 0.1 μm) can penetrate deep into the lungs and potentially have adverse health effects. However, epidemiological data on the health effects of UFP is limited. Therefore, our objective was to test the hypothesis that exposure to UFPs is associated with respiratory health status and systemic inflammation among children aged 8 to 11 years. We conducted a cross-sectional study among 655 children (43.3% male) attending 25 primary (elementary) schools in the Brisbane Metropolitan Area, Australia. Ultrafine particle number concentration (PNC) was measured at each school and modelled at homes using Land Use Regression to derive exposure estimates. Health outcomes were respiratory symptoms and diagnoses, measured by parent-completed questionnaire, spirometric lung function, exhaled nitric oxide (FeNO), and serum C reactive protein (CRP). Exposure-response models, adjusted for potential personal and environmental confounders measured at the individual, home and school level, were fitted using Bayesian methods. PNC was not independently associated with respiratory symptoms, asthma diagnosis or spirometric lung function. However, PNC was positively associated with an increase in CRP (1.188-fold change per 1000 UFP cm -3 day/day (95% credible interval 1.077 to 1.299)) and an increase in FeNO among atopic participants (1.054 fold change per 1000 UFP cm -3 day/day (95% CrI 1.005 to 1.106)). UFPs do not affect respiratory health outcomes in children but do have systemic effects, detected here in the form of a positive association with a biomarker for systemic inflammation. This is consistent with the known propensity of UFPs to penetrate deep into the lung and circulatory system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josephson, Gary B.; Geeting, John GH; Bredt, Ofelia P.

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Waste Treatment Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes." The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEPmore » also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-1, the 19-M NaOH is added to un-concentrated waste slurry (3-8 wt% solids), while for leaching in UFP-2, the slurry is concentrated to nominally 20 wt% solids using cross

  3. Ultrafine particles in cities.

    PubMed

    Kumar, Prashant; Morawska, Lidia; Birmili, Wolfram; Paasonen, Pauli; Hu, Min; Kulmala, Markku; Harrison, Roy M; Norford, Leslie; Britter, Rex

    2014-05-01

    Ultrafine particles (UFPs; diameter less than 100 nm) are ubiquitous in urban air, and an acknowledged risk to human health. Globally, the major source for urban outdoor UFP concentrations is motor traffic. Ongoing trends towards urbanisation and expansion of road traffic are anticipated to further increase population exposure to UFPs. Numerous experimental studies have characterised UFPs in individual cities, but an integrated evaluation of emissions and population exposure is still lacking. Our analysis suggests that the average exposure to outdoor UFPs in Asian cities is about four-times larger than that in European cities but impacts on human health are largely unknown. This article reviews some fundamental drivers of UFP emissions and dispersion, and highlights unresolved challenges, as well as recommendations to ensure sustainable urban development whilst minimising any possible adverse health impacts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Ultrafine particle emissions by in-use diesel buses of various generations at low-load regimes

    NASA Astrophysics Data System (ADS)

    Tartakovsky, L.; Baibikov, V.; Comte, P.; Czerwinski, J.; Mayer, A.; Veinblat, M.; Zimmerli, Y.

    2015-04-01

    Ultrafine particles (UFP) are major contributors to air pollution due to their easy gas-like penetration into the human organism, causing adverse health effects. This study analyzes UFP emissions by buses of different technologies (from Euro II till Euro V EEV - Enhanced Environmentally-friendly Vehicle) at low-load regimes. Additionally, the emission-reduction potential of retrofitting with a diesel particle filter (DPF) is demonstrated. A comparison of the measured, engine-out, particle number concentrations (PNC) for buses of different technological generations shows that no substantial reduction of engine-out emissions at low-load operating modes is observed for newer bus generations. Retrofitting the in-use urban and interurban buses of Euro II till Euro IV technologies by the VERT-certified DPF confirmed its high efficiency in reduction of UFP emissions. Particle-count filtration efficiency values of the retrofit DPF were found to be extremely high - greater than 99.8%, similar to that of the OEM filter in the Euro V bus.

  5. Short-term effects of ultrafine particles on daily mortality by primary vehicle exhaust versus secondary origin in three Spanish cities.

    PubMed

    Tobías, Aurelio; Rivas, Ioar; Reche, Cristina; Alastuey, Andrés; Rodríguez, Sergio; Fernández-Camacho, Rocío; Sánchez de la Campa, Ana M; de la Rosa, Jesús; Sunyer, Jordi; Querol, Xavier

    2018-02-01

    Evidence on the short-term effects of ultrafine particles (with diameter<100nm, UFP) on health is still inconsistent. New particles in ambient urban air are the result of direct emissions and also the formation of secondary UFP from gaseous precursors. We segregated UFP into these two components and investigated their impact on daily mortality in three Spanish cities affected by different sources of air pollution. We separated the UFP using a method based on the high correlation between black carbon (BC) and particle number concentration (N). The first component accounts for aerosol constituents emitted by vehicle exhaust (N1) and the second for the photochemical new particle formation enhancements (N2). We applied city-specific Poisson regression models, adjusting for long-term trends, temperature and population dynamics. Mean BC levels were higher in Barcelona and Tenerife (1.8 and 1.2μg·m -3 , respectively) than in Huelva (0.8μg·m -3 ). While mean UFP concentrations were similar in the three cities, from which N1 was 40% in Barcelona, 46% in Santa Cruz de Tenerife, and 27% in Huelva. We observed an association with N1 and daily mortality in Barcelona, by increasing approximately 1.5% between lags 0 and 2, per an interquartile increase (IQR) of 3277cm -3 , but not with N2. A similar pattern was found in Santa Cruz de Tenerife, although none of the associations were significant. Conversely, in the industrial city of Huelva mortality was associated with N2 at lag 0, by increasing 3.9% per an IQR of 12,032·cm -3 . The pattern and origin of UFP determines their short-term effect on human health. BC is possibly the better parameter to evaluate the health effects of particulate vehicle exhaust emissions, although in areas influenced by domestic solid fuel combustion this should also be taken into account. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Ultrafine particles from diesel vehicle emissions at different driving cycles induce differential vascular pro-inflammatory responses: Implication of chemical components and NF-κB signaling

    PubMed Central

    2010-01-01

    Background Epidemiological evidence supports the association between exposure to ambient particulate matter (PM) and cardiovascular diseases. Chronic exposure to ultrafine particles (UFP; Dp <100 nm) is reported to promote atherosclerosis in ApoE knockout mice. Atherogenesis-prone factors induce endothelial dysfunction that contributes to the initiation and progression of atherosclerosis. We previously demonstrated that UFP induced oxidative stress via c-Jun N-terminal Kinases (JNK) activation in endothelial cells. In this study, we investigated pro-inflammatory responses of human aortic endothelial cells (HAEC) exposed to UFP emitted from a diesel truck under an idling mode (UFP1) and an urban dynamometer driving schedule (UFP2), respectively. We hypothesize that UFP1 and UFP2 with distinct chemical compositions induce differential pro-inflammatory responses in endothelial cells. Results UFP2 contained a higher level of redox active organic compounds and metals on a per PM mass basis than UFP1. While both UFP1 and UFP2 induced superoxide production and up-regulated stress response genes such as heme oxygenease-1 (HO-1), OKL38, and tissue factor (TF), only UFP2 induced the expression of pro-inflammatory genes such as IL-8 (2.8 ± 0.3-fold), MCP-1 (3.9 ± 0.4-fold), and VCAM (6.5 ± 1.1-fold) (n = 3, P < 0.05). UFP2-exposed HAEC also bound to a higher number of monocytes than UFP1-exposed HAEC (Control = 70 ± 7.5, UFP1 = 106.7 ± 12.5, UFP2 = 137.0 ± 8.0, n = 3, P < 0.05). Adenovirus NF-κB Luciferase reporter assays revealed that UFP2, but not UFP1, significantly induced NF-κB activities. NF-κB inhibitor, CAY10512, significantly abrogated UFP2-induced pro-inflammatory gene expression and monocyte binding. Conclusion While UFP1 induced higher level of oxidative stress and stress response gene expression, only UFP2, with higher levels of redox active organic compounds and metals, induced pro-inflammatory responses via NF-κB signaling. Thus, UFP with distinct

  7. Short-Term Mortality Rates during a Decade of Improved Air Quality in Erfurt, Germany

    PubMed Central

    Breitner, Susanne; Stölzel, Matthias; Cyrys, Josef; Pitz, Mike; Wölke, Gabriele; Kreyling, Wolfgang; Küchenhoff, Helmut; Heinrich, Joachim; Wichmann, H.-Erich; Peters, Annette

    2009-01-01

    Background Numerous studies have shown associations between ambient air pollution and daily mortality. Objectives Our goal was to investigate the association of ambient air pollution and daily mortality in Erfurt, Germany, over a 10.5-year period after the German unification, when air quality improved. Methods We obtained daily mortality counts and data on mass concentrations of particulate matter (PM) < 10 μm in aerodynamic diameter (PM10), gaseous pollutants, and meteorology in Erfurt between October 1991 and March 2002. We obtained ultrafine particle number concentrations (UFP) and mass concentrations of PM < 2.5 μm in aerodynamic diameter (PM2.5) from September 1995 to March 2002. We analyzed the data using semiparametric Poisson regression models adjusting for trend, seasonality, influenza epidemics, day of the week, and meteorology. We evaluated cumulative associations between air pollution and mortality using polynomial distributed lag (PDL) models and multiday moving averages of air pollutants. We evaluated changes in the associations over time in time-varying coefficient models. Results Air pollution concentrations decreased over the study period. Cumulative exposure to UFP was associated with increased mortality. An interquartile range (IQR) increase in the 15-day cumulative mean UFP of 7,649 cm−3 was associated with a relative risk (RR) of 1.060 [95% confidence interval (CI), 1.008–1.114] for PDL models and an RR/IQR of 1.055 (95% CI, 1.011–1.101) for moving averages. RRs decreased from the mid-1990s to the late 1990s. Conclusion Results indicate an elevated mortality risk from short-term exposure to UFP. They further suggest that RRs for short-term associations of air pollution decreased as pollution control measures were implemented in Eastern Germany. PMID:19337521

  8. Indoor/outdoor relationships of quasi-ultrafine, accumulation and coarse mode particles in school environments in Barcelona: chemical composition and sources

    NASA Astrophysics Data System (ADS)

    Viana, M.; Rivas, I.; Querol, X.; Alastuey, A.; Sunyer, J.; Álvarez-Pedrerol, M.; Bouso, L.; Sioutas, C.

    2013-12-01

    The mass concentration, chemical composition and sources of quasi-ultrafine (quasi-UFP, PM0.25), accumulation (PM0.25-2.5) and coarse mode (PM2.5-10) particles were determined in indoor and outdoor air at 39 schools in Barcelona (Spain). Quasi-UFP mass concentrations measured (25.6 μg m-3 outdoors, 23.4 μg m-3 indoors) are significantly higher than those reported in other studies, and characterised by higher carbonaceous and mineral matter contents and a lower proportion of secondary inorganic ions. Results suggest that quasi-UFPs in Barcelona are affected by local sources in the schools, mainly human activity (e.g. organic material from textiles, etc.; contributing 23-46% to total quasi-UFP mass) and playgrounds (in the form of mineral matter, contributing about 9% to the quasi-UFP mass). The particle size distribution of toxicologically relevant metals and major aerosol components was characterised, displaying bimodal size distributions for most elements and components, and a unimodal distribution for inorganic salts (ammonium nitrate and sulphate) and elemental carbon (EC). Regarding metals, Ni and Cr were partitioned mainly in quasi-UFPs and could thus be of interest for epidemiological studies, given their high redox properties. Children exposure to quasi-UFP mass and chemical species was assessed by comparing the concentrations measured at urban background and traffic areas schools. Finally, three main indoor sources across all size fractions were identified by assessing indoor/outdoor ratios (I/O) of PM species used as their tracers: human activity (organic material), cleaning products, paints and plastics (Cl- source), and a metallic mixed source (comprising combinations of Cu, Zn, Co, Cd, Pb, As, V and Cr).

  9. Exposure to ultrafine particles and black carbon in diesel-powered commuter trains

    NASA Astrophysics Data System (ADS)

    Jeong, Cheol-Heon; Traub, Alison; Evans, Greg J.

    2017-04-01

    Ultrafine particle (UFP), black carbon (BC) and lung deposited surface area (LDSA) concentrations measured during 43 trips on diesel-powered commuter trains revealed elevated exposures under some conditions. When the passenger coaches were pulled by a locomotive, the geometric mean concentrations of UFP, LDSA, and BC were 18, 10, and 6 times higher than the exposure levels when the locomotive pushed the coaches, respectively. In addition, UFP, LDSA, and BC concentrations in pull-trains were 5, 3, and 4 times higher than concentrations measured while walking on city sidewalks, respectively. Exposure to these pollutants was most elevated in the coach located closest to the locomotive: geometric means were 126,000 # cm-3 for UFP, 249 μm2 cm-3 for LDSA, and 17,800 ng m-3 of BC; these concentrations are much higher than those previously reported for other modes of public transportation. Markedly high levels of diesel exhaust are present in passenger trains powered by diesel locomotives operated in pull-mode. Thus, it is recommended that immediate steps be taken to evaluate, and where needed, mitigate exposure in diesel-powered passenger trains, both commuter and inter-city.

  10. Human peripheral blood mononuclear cells (PBMCs) from smokers release higher levels of IL-1-like cytokines after exposure to combustion-generated ultrafine particles

    PubMed Central

    De Falco, Gianluigi; Terlizzi, Michela; Sirignano, Mariano; Commodo, Mario; D’Anna, Andrea; Aquino, Rita P.; Pinto, Aldo; Sorrentino, Rosalinda

    2017-01-01

    Ultrafine particles (UFP) generated by combustion processes are often associated with adverse health effects. However, little is known about the inflammatory processes generated by UFP that may underlie their toxicological activity. Murine macrophages (J774.1 cells) and human peripheral blood mononuclear cells (PBMCs) were used to evaluate the molecular mechanism underlying the pro-inflammatory activity of UFP. The addition of soot particles to J774.1 cells induced a concentration-dependent release of IL-1α, IL-1β and IL-33 This effect was not associated with cell death and, in contrast to literature, was pronounced at very low concentrations (5–100 pg/ml). Similarly, UFP induced the release of IL-1α, IL-18 and IL-33 by PBMCs. However, this effect was solely observed in PBMCs obtained from smokers, as the PBMCs from non-smokers instead released higher levels of IL-10. The release of these cytokines after UFP exposure was caspase-1- and NLRP3 inflammasome-dependent in PBMCs from healthy smokers, whereas IL-1α release was calpain-dependent. These results show that UFP at very low concentrations are able to give rise to an inflammatory process that is responsible for IL-1α, IL-18 and IL-33 release, which is pronounced in PBMCs from smokers, confirming that these individuals are especially susceptible to inflammatory-based airway diseases once exposed to air pollution. PMID:28223692

  11. Seasonal variations of number size distributions and mass concentrations of atmospheric particles in Beijing

    NASA Astrophysics Data System (ADS)

    Yu, Jianhua; Guinot, Benjamin; Yu, Tong; Wang, Xin; Liu, Wenqing

    2005-06-01

    Particle number and mass concentrations were measured in Beijing during the winter and summer periods in 2003, together with some other parameters including black carbon (BC) and meteorological conditions. Particle mass concentrations exhibited low seasonality, and the ratio of PM2.5/PM10 in winter was higher than that in summer. Particle number size distribution (PSD) was characterized by four modes and exhibited low seasonality. BC was well correlated with the number and mass concentrations of accumulation and coarse particles, indicating these size particles are related to anthropogenic activities. Particle mass and number concentrations (except ultra-fine and nucleation particles) followed well the trends of BC concentration for the majority of the day, indicating that most particles were associated with primary emissions. The diurnal number distributions of accumulation and coarse mode particles were characterized by two peaks.

  12. What Controls the Low Ice Number Concentration in the Upper Tropical Troposphere?

    NASA Astrophysics Data System (ADS)

    Penner, J.; Zhou, C.; Lin, G.; Liu, X.; Wang, M.

    2015-12-01

    Cirrus clouds in the tropical tropopause play a key role in regulating the moisture entering the stratosphere through their dehydrating effect. Low ice number concentrations and high supersaturations were frequently were observed in these clouds. However, low ice number concentrations are inconsistent with cirrus cloud formation based on homogeneous freezing. Different mechanisms have been proposed to explain this discrepancy, including the inhibition of homogeneous freezing by pre-existing ice crystals and/or glassy organic aerosol heterogeneous ice nuclei (IN) and limiting the formation of ice number from high frequency gravity waves. In this study, we examined the effect from three different parameterizations of in-cloud updraft velocities, the effect from pre-existing ice crystals, the effect from different water vapor deposition coefficients (α=0.1 or 1), and the effect from 0.1% of secondary organic aerosol (SOA) acting as glassy heterogeneous ice nuclei (IN) in CAM5. Model simulated ice crystal numbers are compared against an aircraft observational dataset. Using grid resolved large-scale updraft velocity in the ice nucleation parameterization generates ice number concentrations in better agreement with observations for temperatures below 205K while using updraft velocities based on the model-generated turbulence kinetic energy generates ice number concentrations in better agreement with observations for temperatures above 205K. A larger water vapor deposition coefficient (α=1) can efficiently reduce the ice number at temperatures below 205K but less so at higher temperatures. Glassy SOA IN are most effective at reducing the ice number concentrations when the effective in-cloud updraft velocities are moderate (~0.05-0.2 m s-1). Including the removal of water vapor on pre-existing ice can also effectively reduce the ice number and diminish the effects from the additional glassy SOA heterogeneous IN. We also re-evaluate whether IN seeding in cirrus cloud is

  13. Respiratory Health Effects of Ultrafine Particles in Children: A Literature Review

    PubMed Central

    Heinzerling, Amy; Hsu, Joy; Yip, Fuyuen

    2015-01-01

    By convention, airborne particles ≤0.1 μm (100 nm) are defined as ultrafine particles (UFPs). UFPs can comprise a large number of particles in particulate matter with aerodynamic diameters ≤2.5 μm (PM2.5). Despite the documented respiratory health effects of PM2.5 and concerns that UFPs might be more toxic than larger particular matter, the effects of UFPs on the respiratory system are not well-described. Even less is known about the respiratory health effects of UFPs among particularly vulnerable populations including children. We reviewed studies examining respiratory health effects of UFPs in children and identified 12 relevant articles. Most (8/12) studies measured UFP exposure using central ambient monitors, and we found substantial heterogeneity in UFP definitions and study designs. No long-term studies were identified. In single pollutant models, UFPs were associated with incident wheezing, current asthma, lower spirometric values, and asthma-related emergency department visits among children. Also, higher exhaled nitric oxide levels were positively correlated with UFP dose among children with asthma or allergy to house dust mites in 1 study. Multivariate models accounting for potential co-pollutant confounding yielded no statistically significant results. Although evidence for a relationship between UFPs and children's respiratory is accumulating, the literature remains inconclusive. Interpretation of existing data is constrained by study heterogeneity, limited accounting for UFP spatial variation, and lack of significant findings from multi-pollutant models. PMID:26783373

  14. Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: model development and evaluation.

    PubMed

    Weichenthal, Scott; Dufresne, André; Infante-Rivard, Claire; Joseph, Lawrence

    2008-03-01

    School classrooms are potentially important micro-environments for childhood exposures owing to the large amount of time children spend in these locations. While a number of airborne contaminants may be present in schools, to date few studies have examined ultrafine particle (0.02-1 microm) (UFP) levels in classrooms. In this study, our objective was to characterize UFP counts (cm(-3)) in classrooms during the winter months and to develop a model to predict such exposures based on ambient weather conditions and outdoor UFPs, as well as classroom characteristics such as size, temperature, relative humidity, and carbon dioxide levels. In total, UFP count data were collected on 60 occasions in 37 occupied classrooms at one elementary school and one secondary school in Pembroke, Ontario. On average, outdoor UFP levels exceeded indoor measures by 8989 cm(-3) (95% confidence interval (CI): 6382, 11596), and classroom UFP counts were similar at both schools with a combined average of 5017 cm(-3) (95% CI: 4300, 5734). Of the variables examined only wind speed and outdoor UFPs were important determinants of classrooms UFP levels. Specifically, each 10 km/h increase in wind speed corresponded to an 1873 cm(-3) (95% CI: 825, 2920) decrease in classroom UFP counts, and each 10000 cm(-3) increase in outdoor UFPs corresponded to a 1550 cm(-3) (95% CI: 930, 2171) increase in classroom UFP levels. However, high correlations between these two predictors meant that the independent effects of wind speed and outdoor UFPs could not be separated in multivariable models, and only outdoor UFP counts were included in the final predictive model. To evaluate model performance, classroom UFP counts were collected for 8 days at two new schools and compared to predicted values based on outdoor UFP measures. A moderate correlation was observed between measured and predicted classroom UFP counts (r=0.63) for both schools combined, but this relationship was not valid on days in which a strong

  15. Modeling particle number concentrations along Interstate 10 in El Paso, Texas

    PubMed Central

    Olvera, Hector A.; Jimenez, Omar; Provencio-Vasquez, Elias

    2014-01-01

    Annual average daily particle number concentrations around a highway were estimated with an atmospheric dispersion model and a land use regression model. The dispersion model was used to estimate particle concentrations along Interstate 10 at 98 locations within El Paso, Texas. This model employed annual averaged wind speed and annual average daily traffic counts as inputs. A land use regression model with vehicle kilometers traveled as the predictor variable was used to estimate local background concentrations away from the highway to adjust the near-highway concentration estimates. Estimated particle number concentrations ranged between 9.8 × 103 particles/cc and 1.3 × 105 particles/cc, and averaged 2.5 × 104 particles/cc (SE 421.0). Estimates were compared against values measured at seven sites located along I10 throughout the region. The average fractional error was 6% and ranged between -1% and -13% across sites. The largest bias of -13% was observed at a semi-rural site where traffic was lowest. The average bias amongst urban sites was 5%. The accuracy of the estimates depended primarily on the emission factor and the adjustment to local background conditions. An emission factor of 1.63 × 1014 particles/veh-km was based on a value proposed in the literature and adjusted with local measurements. The integration of the two modeling techniques ensured that the particle number concentrations estimates captured the impact of traffic along both the highway and arterial roadways. The performance and economical aspects of the two modeling techniques used in this study shows that producing particle concentration surfaces along major roadways would be feasible in urban regions where traffic and meteorological data are readily available. PMID:25313294

  16. Exposure to Inhalable, Respirable, and Ultrafine Particles in Welding Fume

    PubMed Central

    Pesch, Beate

    2012-01-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m−3 for inhalable and 1.29 mg m−3 for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m−3). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements Concentrations were mainly predicted by the welding process and were significantly higher when local exhaust ventilation (LEV) was inefficient or when welding was performed in confined spaces. Substitution of high-emission techniques like FCAW, efficient LEV, and using PAPRs where applicable can reduce exposure to welding fume. However, harmonizing the different exposure metrics for UFP (as particle counts) and for the respirable or inhalable fraction of the welding fume (expressed as their mass) remains challenging. PMID:22539559

  17. Exposure to inhalable, respirable, and ultrafine particles in welding fume.

    PubMed

    Lehnert, Martin; Pesch, Beate; Lotz, Anne; Pelzer, Johannes; Kendzia, Benjamin; Gawrych, Katarzyna; Heinze, Evelyn; Van Gelder, Rainer; Punkenburg, Ewald; Weiss, Tobias; Mattenklott, Markus; Hahn, Jens-Uwe; Möhlmann, Carsten; Berges, Markus; Hartwig, Andrea; Brüning, Thomas

    2012-07-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m(-3) for inhalable and 1.29 mg m(-3) for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m(-3)). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements Concentrations were mainly predicted by the welding process and were significantly higher when local exhaust ventilation (LEV) was inefficient or when welding was performed in confined spaces. Substitution of high-emission techniques like FCAW, efficient LEV, and using PAPRs where applicable can reduce exposure to welding fume. However, harmonizing the different exposure metrics for UFP (as particle counts) and for the respirable or inhalable fraction of the welding fume (expressed as their mass) remains challenging.

  18. Effect of Number of Zones on Subjective Vision in Concentric Bifocal Optics.

    PubMed

    Legras, Richard; Rio, David

    2015-11-01

    To evaluate the influence of the number of concentric zones of a center-near bifocal optics on the subjective quality of vision. Twenty-two subjects scored with a five-item continuous grading scale the quality of vision of calculated images (i.e., three high-contrast 20/50 letters) viewed through their best sphero-cylindrical correction and a 3-mm pupil to limit the impact of their aberrations. Through-focus images were calculated from -4 to +2 diopters (D), each 0.25 D, in the presence of center-near bifocal optics (Add 2.5 D) varying by their number of concentric zones (from 2 to 20). To compare the results obtained with these profiles, we calculated the area under the (through-focus) curve (AUC) higher than 2 out of 5 (i.e., limit between a poor and a fair image quality, considered as the limit of acceptability). This value was normalized by the naked eye condition and divided into distance, intermediate, and near AUC. The results showed large interindividual variations. Distance AUC remained quite similar whatever the profile, near AUC decreased with the number of concentric zones, and intermediate AUC rose with the number of concentric zones. With 10 and 20 concentric zones, diffraction phenomenon induced constructive interferences at intermediate proximities and destructive interferences at distance and near proximities. To balance distance, intermediate, and near quality of vision, a number of zones between 8 and 10 should be chosen. If the subject does not need intermediate quality of vision, then a profile with two to five zones should be favored.

  19. Occupational exposure to ultrafine particles in police officers: no evidence for adverse respiratory effects.

    PubMed

    Jordakieva, G; Grabovac, I; Valic, E; Schmidt, K E; Graff, A; Schuster, A; Hoffmann-Sommergruber, K; Oberhuber, C; Scheiner, O; Goll, A; Godnic-Cvar, J

    2018-01-01

    Inhalation exposure to fine and ultrafine particles (UFPs) has been associated with respiratory diseases. However, little is known on the quality, threshold levels and concentration of these particles causing adverse health effects. The impact of occupational exposure to submicrometer and UFPs was assessed in 30 healthy police shooting instructors by clinical investigation, self-assessment questionnaire, sputum and spirometry and compared to a control group. General laboratory chemistry parameters, circulating cytokines (interleukin [IL]-2, IL-4, IL-5, IL-6, IL-8, interferon-gamma [IFN-γ]), and granulocyte macrophage colony-stimulating factor (GM-CSF) in serum were measured. UFP exposure was recorded by Scanning Mobility Particle Sizer. Concentrations of submicrometer sized airborne particles (< 700 nm) measured between 3.34 × 10 5 /cm 3 and 7.58 × 10 5 /cm 3 at shooting sites, with highest concentrations found in the UFP range (< 100 nm). The size of the monodispersed particles ranged from 54.74 ± 16.25 nm to 98.19 ± 22.83 nm. Short term exposure (4 h) to high levels of UFPs caused an increase of IFN-γ in exposed subjects ( p  = 0.022). 24 h after exposure a significant decrease of IgG, albumin fibrinogen and factor VII was found. Neither directly after 4 h of high levels UFPs exposure nor 24 h after exposure subjective complaints or objective measurements indicating adverse respiratory effects in exposed subjects were found. No consistent indications for adverse respiratory or inflammatory effects directly following exposure and 24 h after exposure to high levels of UFPs in our study group were detected. However we showed the assessment of short-term exposure effects at a genuine occupational setting, which might is relevant when a risk assessment of high level occupational exposures to UFPs is considered.

  20. PEP Support Laboratory Leaching and Permeate Stability Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.

    2009-09-25

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes.more » The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-VSL-T01A and B, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for

  1. Source apportionment of aerosol particles at a European air pollution hot spot using particle number size distributions and chemical composition.

    PubMed

    Leoni, Cecilia; Pokorná, Petra; Hovorka, Jan; Masiol, Mauro; Topinka, Jan; Zhao, Yongjing; Křůmal, Kamil; Cliff, Steven; Mikuška, Pavel; Hopke, Philip K

    2018-03-01

    Ostrava in the Moravian-Silesian region (Czech Republic) is a European air pollution hot spot for airborne particulate matter (PM), polycyclic aromatic hydrocarbons (PAHs), and ultrafine particles (UFPs). Air pollution source apportionment is essential for implementation of successful abatement strategies. UFPs or nanoparticles of diameter <100 nm exhibit the highest deposition efficiency in human lungs. To permit apportionment of PM sources at the hot-spot including nanoparticles, Positive Matrix Factorization (PMF) was applied to highly time resolved particle number size distributions (NSD, 14 nm-10 μm) and PM 0.09-1.15 chemical composition. Diurnal patterns, meteorological variables, gaseous pollutants, organic markers, and associations between the NSD factors and chemical composition factors were used to identify the pollution sources. The PMF on the NSD reveals two factors in the ultrafine size range: industrial UFPs (28%, number mode diameter - NMD 45 nm), industrial/fresh road traffic nanoparticles (26%, NMD 26 nm); three factors in the accumulation size range: urban background (24%, NMD 93 nm), coal burning (14%, volume mode diameter - VMD 0.5 μm), regional pollution (3%, VMD 0.8 μm) and one factor in the coarse size range: industrial coarse particles/road dust (2%, VMD 5 μm). The PMF analysis of PM 0.09-1.15 revealed four factors: SIA/CC/BB (52%), road dust (18%), sinter/steel (16%), iron production (16%). The factors in the ultrafine size range resolved with NSD have a positive correlation with sinter/steel production and iron production factors resolved with chemical composition. Coal combustion factor resolved with NSD has moderate correlation with SIA/CC/BB factor. The organic markers homohopanes correlate with coal combustion and the levoglucosan correlates with urban background. The PMF applications to NSD and chemical composition datasets are complementary. PAHs in PM 1 were found to be associated with coal combustion factor. Copyright

  2. Pedestrians in Traffic Environments: Ultrafine Particle Respiratory Doses

    PubMed Central

    Manigrasso, Maurizio; Natale, Claudio; Vitali, Matteo; Protano, Carmela; Avino, Pasquale

    2017-01-01

    Particulate matter has recently received more attention than other pollutants. PM10 and PM2.5 have been primarily monitored, whereas scientists are focusing their studies on finer granulometric sizes due both to their high number concentration and their high penetration efficiency into the respiratory system. The purpose of this study is to investigate the population exposure to UltraFine Particles (UFP, submicrons in general) in outdoor environments. The particle number doses deposited into the respiratory system have been compared between healthy individuals and persons affected by Chronic Obstructive Pulmonary Disease (COPD). Measurements were performed by means of Dust Track and Nanoscan analyzers. Forty minute walking trails through areas with different traffic densities in downtown Rome have been considered. Furthermore, particle respiratory doses have been estimated for persons waiting at a bus stop, near a traffic light, or along a high-traffic road, as currently occurs in a big city. Large differences have been observed between workdays and weekdays: on workdays, UFP number concentrations are much higher due to the strong contribution of vehicular exhausts. COPD-affected individuals receive greater doses than healthy individuals due to their higher respiratory rate. PMID:28282961

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weichenthal, Scott; Dufresne, Andre; Infante-Rivard, Claire

    School classrooms are potentially important micro-environments for childhood exposures owing to the large amount of time children spend in these locations. While a number of airborne contaminants may be present in schools, to date few studies have examined ultrafine particle (0.02-1 {mu}m) (UFP) levels in classrooms. In this study, our objective was to characterize UFP counts (cm{sup -3}) in classrooms during the winter months and to develop a model to predict such exposures based on ambient weather conditions and outdoor UFPs, as well as classroom characteristics such as size, temperature, relative humidity, and carbon dioxide levels. In total, UFP countmore » data were collected on 60 occasions in 37 occupied classrooms at one elementary school and one secondary school in Pembroke, Ontario. On average, outdoor UFP levels exceeded indoor measures by 8989 cm{sup -3} (95% confidence interval (CI): 6382, 11 596), and classroom UFP counts were similar at both schools with a combined average of 5017 cm{sup -3} (95% CI: 4300, 5734). Of the variables examined only wind speed and outdoor UFPs were important determinants of classrooms UFP levels. Specifically, each 10 km/h increase in wind speed corresponded to an 1873 cm{sup -3} (95% CI: 825, 2920) decrease in classroom UFP counts, and each 10 000 cm{sup -3} increase in outdoor UFPs corresponded to a 1550 cm{sup -3} (95% CI: 930, 2171) increase in classroom UFP levels. However, high correlations between these two predictors meant that the independent effects of wind speed and outdoor UFPs could not be separated in multivariable models, and only outdoor UFP counts were included in the final predictive model. To evaluate model performance, classroom UFP counts were collected for 8 days at two new schools and compared to predicted values based on outdoor UFP measures. A moderate correlation was observed between measured and predicted classroom UFP counts (r=0.63) for both schools combined, but this relationship was not

  4. Source and Health Implication of Diurnal Atmospheric PM Mass and Number Concentrations

    NASA Astrophysics Data System (ADS)

    Li, W.; Olvera, H. A.; Garcia, J. H.; Pingitore, N. E.

    2007-12-01

    Exposure to atmospheric PM has been known to be associated with adverse health effects, decreased heart-rate variability, and respiratory and cardiopulmonary related morbidity and mortality. New evidence suggests that physical characteristics (mass, size, number, surface area, and morphology) of particles are strongly associated with mortality and morbidity through acute exposure. In particular, as reported in the literature, fine or ultrafine particles are more toxic than coarse particles on an equivalent mass basis while particles of less than 30 nm or greater than 2.5 um in diameter deposit more effectively (approximately 80 percent) in lung versus approximately 18 percent for particles in the range of 100 nm and 1 um. In addition, positive association has been observed between day to day variation in PM2.5 and hospital admissions, mortality and particle surface area, or particle number concentration and oxidative stress-induced DNA damage. This presentation shows the results of a study characterizing the physical properties of PM in El Paso, Texas. Diurnal PM mass concentration peaks previously observed at several other cities along the U.S.-Mexico border and elsewhere in the world were observed in El Paso. The hourly PM particle count varied from less than 10,000 particles/cm3 to greater than 80,000 particles/cm3 during the diurnal PM mass peaks. The total number of PM particles peaked in the morning and in the evening while the mode of the particle size changed from 20 nm to 50 nm, indicating different PM sources may be responsible for the mass and number concentrations and agglomeration of particles in the atmosphere during the day may possibly plays a role. A multivariate regression analysis was performed to correlate the PM mass and number concentrations to environmental variables. Real- time wind statistics were used in conjunction with traffic data at a nearby highway for identifying sources of the PM mass and number concentration peaks. Evaluation of

  5. In situ formation and spatial variability of particle number concentration in a European megacity

    NASA Astrophysics Data System (ADS)

    Pikridas, M.; Sciare, J.; Freutel, F.; Crumeyrolle, S.; von der Weiden-Reinmüller, S.-L.; Borbon, A.; Schwarzenboeck, A.; Merkel, M.; Crippa, M.; Kostenidou, E.; Psichoudaki, M.; Hildebrandt, L.; Engelhart, G. J.; Petäjä, T.; Prévôt, A. S. H.; Drewnick, F.; Baltensperger, U.; Wiedensohler, A.; Kulmala, M.; Beekmann, M.; Pandis, S. N.

    2015-09-01

    Ambient particle number size distributions were measured in Paris, France, during summer (1-31 July 2009) and winter (15 January to 15 February 2010) at three fixed ground sites and using two mobile laboratories and one airplane. The campaigns were part of the Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation (MEGAPOLI) project. New particle formation (NPF) was observed only during summer on approximately 50 % of the campaign days, assisted by the low condensation sink (about 10.7 ± 5.9 × 10-3 s-1). NPF events inside the Paris plume were also observed at 600 m altitude onboard an aircraft simultaneously with regional events identified on the ground. Increased particle number concentrations were measured aloft also outside of the Paris plume at the same altitude, and were attributed to NPF. The Paris plume was identified, based on increased particle number and black carbon concentration, up to 200 km away from the Paris center during summer. The number concentration of particles with diameters exceeding 2.5 nm measured on the surface at the Paris center was on average 6.9 ± 8.7 × 104 and 12.1 ± 8.6 × 104 cm-3 during summer and winter, respectively, and was found to decrease exponentially with distance from Paris. However, further than 30 km from the city center, the particle number concentration at the surface was similar during both campaigns. During summer, one suburban site in the NE was not significantly affected by Paris emissions due to higher background number concentrations, while the particle number concentration at the second suburban site in the SW increased by a factor of 3 when it was downwind of Paris.

  6. Explaining global surface aerosol number concentrations in terms of primary emissions and particle formation

    NASA Astrophysics Data System (ADS)

    Spracklen, D. V.; Carslaw, K. S.; Merikanto, J.; Mann, G. W.; Reddington, C. L.; Pickering, S.; Ogren, J. A.; Andrews, E.; Baltensperger, U.; Weingartner, E.; Boy, M.; Kulmala, M.; Laakso, L.; Lihavainen, H.; Kivekäs, N.; Komppula, M.; Mihalopoulos, N.; Kouvarakis, G.; Jennings, S. G.; O'Dowd, C.; Birmili, W.; Wiedensohler, A.; Weller, R.; Gras, J.; Laj, P.; Sellegri, K.; Bonn, B.; Krejci, R.; Laaksonen, A.; Hamed, A.; Minikin, A.; Harrison, R. M.; Talbot, R.; Sun, J.

    2010-05-01

    We synthesised observations of total particle number (CN) concentration from 36 sites around the world. We found that annual mean CN concentrations are typically 300-2000 cm-3 in the marine boundary layer and free troposphere (FT) and 1000-10 000 cm-3 in the continental boundary layer (BL). Many sites exhibit pronounced seasonality with summer time concentrations a factor of 2-10 greater than wintertime concentrations. We used these CN observations to evaluate primary and secondary sources of particle number in a global aerosol microphysics model. We found that emissions of primary particles can reasonably reproduce the spatial pattern of observed CN concentration (R2=0.46) but fail to explain the observed seasonal cycle (R2=0.1). The modeled CN concentration in the FT was biased low (normalised mean bias, NMB=-88%) unless a secondary source of particles was included, for example from binary homogeneous nucleation of sulfuric acid and water (NMB=-25%). Simulated CN concentrations in the continental BL were also biased low (NMB=-74%) unless the number emission of anthropogenic primary particles was increased or a mechanism that results in particle formation in the BL was included. We ran a number of simulations where we included an empirical BL nucleation mechanism either using the activation-type mechanism (nucleation rate, J, proportional to gas-phase sulfuric acid concentration to the power one) or kinetic-type mechanism (J proportional to sulfuric acid to the power two) with a range of nucleation coefficients. We found that the seasonal CN cycle observed at continental BL sites was better simulated by BL particle formation (R2=0.3) than by increasing the number emission from primary anthropogenic sources (R2=0.18). The nucleation constants that resulted in best overall match between model and observed CN concentrations were consistent with values derived in previous studies from detailed case studies at individual sites. In our model, kinetic and activation

  7. Modeling multi-scale aerosol dynamics and micro-environmental air quality near a large highway intersection using the CTAG model.

    PubMed

    Wang, Yan Jason; Nguyen, Monica T; Steffens, Jonathan T; Tong, Zheming; Wang, Yungang; Hopke, Philip K; Zhang, K Max

    2013-01-15

    A new methodology, referred to as the multi-scale structure, integrates "tailpipe-to-road" (i.e., on-road domain) and "road-to-ambient" (i.e., near-road domain) simulations to elucidate the environmental impacts of particulate emissions from traffic sources. The multi-scale structure is implemented in the CTAG model to 1) generate process-based on-road emission rates of ultrafine particles (UFPs) by explicitly simulating the effects of exhaust properties, traffic conditions, and meteorological conditions and 2) to characterize the impacts of traffic-related emissions on micro-environmental air quality near a highway intersection in Rochester, NY. The performance of CTAG, evaluated against with the field measurements, shows adequate agreement in capturing the dispersion of carbon monoxide (CO) and the number concentrations of UFPs in the near road micro-environment. As a proof-of-concept case study, we also apply CTAG to separate the relative impacts of the shutdown of a large coal-fired power plant (CFPP) and the adoption of the ultra-low-sulfur diesel (ULSD) on UFP concentrations in the intersection micro-environment. Although CTAG is still computationally expensive compared to the widely-used parameterized dispersion models, it has the potential to advance our capability to predict the impacts of UFP emissions and spatial/temporal variations of air pollutants in complex environments. Furthermore, for the on-road simulations, CTAG can serve as a process-based emission model; Combining the on-road and near-road simulations, CTAG becomes a "plume-in-grid" model for mobile emissions. The processed emission profiles can potentially improve regional air quality and climate predictions accordingly. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Real-Time Measurements and Characterization of Airborne Particulate Matter from a Primary Silicon Carbide Production Plant.

    PubMed

    Jørgensen, Rikke Bramming; Kero, Ida Teresia

    2017-12-20

    Airborne particulate matter in the silicon carbide (SiC) industry is a known health hazard. The aims of this study were to elucidate whether the particulate matter generated inside the Acheson furnace during active operation is representative of the overall particulate matter in the furnace hall, and whether the Acheson furnaces are the main sources of ultrafine particles (UFP) in primary SiC production. The number concentration of ultrafine particles was evaluated using an Electrical Low Pressure Impactor (ELPI TM , Dekati Ltd., Tampere, Finland), a Fast Mobility Particle Sizer (FMPS TM , TSI, Shoreview, MN, USA) and a Condensation Particle Counter (CPC, TSI, Shoreview, MN, USA). The results are discussed in terms of particle number concentration, particle size distribution and are also characterized by means of electron microscopy (TEM/SEM). Two locations were investigated; the industrial Acheson process furnace hall and a pilot furnace hall; both of which represent an active operating furnace. The geometric mean of the particle number concentration in the Acheson process furnace hall was 7.7 × 10⁴ particles/cm³ for the UFP fraction and 1.0 × 10⁵ particles/cm³ for the submicrometre fraction. Particulate matter collected at the two sites was analysed by electron microscopy. The PM from the Acheson process furnace hall is dominated by carbonaceous particles while the samples collected near the pilot furnace are primarily rich in silicon.

  9. Real-Time Measurements and Characterization of Airborne Particulate Matter from a Primary Silicon Carbide Production Plant

    PubMed Central

    2017-01-01

    Airborne particulate matter in the silicon carbide (SiC) industry is a known health hazard. The aims of this study were to elucidate whether the particulate matter generated inside the Acheson furnace during active operation is representative of the overall particulate matter in the furnace hall, and whether the Acheson furnaces are the main sources of ultrafine particles (UFP) in primary SiC production. The number concentration of ultrafine particles was evaluated using an Electrical Low Pressure Impactor (ELPITM, Dekati Ltd., Tampere, Finland), a Fast Mobility Particle Sizer (FMPSTM, TSI, Shoreview, MN, USA) and a Condensation Particle Counter (CPC, TSI, Shoreview, MN, USA). The results are discussed in terms of particle number concentration, particle size distribution and are also characterized by means of electron microscopy (TEM/SEM). Two locations were investigated; the industrial Acheson process furnace hall and a pilot furnace hall; both of which represent an active operating furnace. The geometric mean of the particle number concentration in the Acheson process furnace hall was 7.7 × 104 particles/cm3 for the UFP fraction and 1.0 × 105 particles/cm3 for the submicrometre fraction. Particulate matter collected at the two sites was analysed by electron microscopy. The PM from the Acheson process furnace hall is dominated by carbonaceous particles while the samples collected near the pilot furnace are primarily rich in silicon. PMID:29261158

  10. Personal exposure to ultrafine particles: the influence of time-activity patterns.

    PubMed

    Buonanno, G; Stabile, L; Morawska, L

    2014-01-15

    Exposure to ultrafine particles (UFPs) is deemed to be a major risk affecting human health. Therefore, airborne particle studies were performed in the recent years to evaluate the most critical micro-environments, as well as identifying the main UFP sources. Nonetheless, in order to properly evaluate the UFP exposure, personal monitoring is required as the only way to relate particle exposure levels to the activities performed and micro-environments visited. To this purpose, in the present work, the results of experimental analysis aimed at showing the effect of the time-activity patterns on UFP personal exposure are reported. In particular, 24 non-smoking couples (12 during winter and summer time, respectively), comprised of a man who worked full-time and a woman who was a homemaker, were analyzed using personal particle counter and GPS monitors. Each couple was investigated for a 48-h period, during which they also filled out a diary reporting the daily activities performed. Time activity patterns, particle number concentration exposure and the related dose received by the participants, in terms of particle alveolar-deposited surface area, were measured. The average exposure to particle number concentration was higher for women during both summer and winter (Summer: women 1.8 × 10(4) part. cm(-3); men 9.2 × 10(3) part. cm(-3); Winter: women 2.9 × 10(4) part. cm(-3); men 1.3 × 10(4) part. cm(-3)), which was likely due to the time spent undertaking cooking activities. Staying indoors after cooking also led to higher alveolar-deposited surface area dose for both women and men during the winter time (9.12 × 10(2) and 6.33 × 10(2) mm(2), respectively), when indoor ventilation was greatly reduced. The effect of cooking activities was also detected in terms of women's dose intensity (dose per unit time), being 8.6 and 6.6 in winter and summer, respectively. On the contrary, the highest dose intensity activity for men was time spent using transportation (2.8 in

  11. Exposure to ultrafine particles in hospitality venues with partial smoking bans.

    PubMed

    Neuberger, Manfred; Moshammer, Hanns; Schietz, Armin

    2013-01-01

    Fine particles in hospitality venues with insufficient smoking bans indicate health risks from passive smoking. In a random sample of Viennese inns (restaurants, cafes, bars, pubs and discotheques) effects of partial smoking bans on indoor air quality were examined by measurement of count, size and chargeable surface of ultrafine particles (UFPs) sized 10-300 nm, simultaneously with mass of particles sized 300-2500 nm (PM2.5). Air samples were taken in 134 rooms unannounced during busy hours and analyzed by a diffusion size classifier and an optical particle counter. Highest number concentrations of particles were found in smoking venues and smoking rooms (median 66,011 pt/cm(3)). Even non-smoking rooms adjacent to smoking rooms were highly contaminated (median 25,973 pt/cm(3)), compared with non-smoking venues (median 7408 pt/cm(3)). The particle number concentration was significantly correlated with the fine particle mass (P<0.001). We conclude that the existing tobacco law in Austria is ineffective to protect customers in non-smoking rooms of hospitality premises. Health protection of non-smoking guests and employees from risky UFP concentration is insufficient, even in rooms labeled "non-smoking". Partial smoking bans with separation of smoking rooms failed.

  12. Particle formation and growth at five rural and urban sites

    NASA Astrophysics Data System (ADS)

    Jeong, C.-H.; Evans, G. J.; McGuire, M. L.; Chang, R. Y.-W.; Abbatt, J. P. D.; Zeromskiene, K.; Mozurkewich, M.; Li, S.-M.; Leaitch, W. R.

    2010-08-01

    Ultrafine particle (UFP) number and size distributions were simultaneously measured at five urban and rural sites during the summer of 2007 in Ontario, Canada as part of the Border Air Quality and Meteorology Study (BAQS-Met 2007). Particle formation and growth events at these five sites were classified based on their strength and persistence as well as the variation in geometric mean diameter. Regional nucleation and growth events and local short-lived strong nucleation events were frequently observed at the near-border rural sites, upwind of industrial sources. Surprisingly, the particle number concentrations at one of these sites were higher than the concentrations at a downtown site in a major city, despite its high traffic density. Regional nucleation and growth events were favored during intense solar irradiance and in less polluted cooler drier air. The most distinctive regional particle nucleation and growth event during the campaign was observed simultaneously at all five sites, which were up to 350 km apart. Although the ultrafine particle concentrations and size distributions generally were spatially heterogeneous across the region, a more uniform spatial distribution of UFP across the five areas was observed during this regional nucleation event. Thus, nucleation events can cover large regions, contributing to the burden of UFP in cities and potentially to the associated health impacts on urban populations. Local short-lived nucleation events at the three near-border sites during this summer three-week campaign were associated with high SO2, which likely originated from US and Canadian industrial sources. Hence, particle formation in southwestern Ontario appears to often be related to anthropogenic gaseous emissions but biogenic emissions at times also contribute. Longer-term studies are needed to help resolve the relative contributions of anthropogenic and biogenic emissions to nucleation and growth in this region.

  13. Personal exposure to ultrafine particles.

    PubMed

    Wallace, Lance; Ott, Wayne

    2011-01-01

    Personal exposure to ultrafine particles (UFP) can occur while people are cooking, driving, smoking, operating small appliances such as hair dryers, or eating out in restaurants. These exposures can often be higher than outdoor concentrations. For 3 years, portable monitors were employed in homes, cars, and restaurants. More than 300 measurement periods in several homes were documented, along with 25 h of driving two cars, and 22 visits to restaurants. Cooking on gas or electric stoves and electric toaster ovens was a major source of UFP, with peak personal exposures often exceeding 100,000 particles/cm³ and estimated emission rates in the neighborhood of 10¹² particles/min. Other common sources of high UFP exposures were cigarettes, a vented gas clothes dryer, an air popcorn popper, candles, an electric mixer, a toaster, a hair dryer, a curling iron, and a steam iron. Relatively low indoor UFP emissions were noted for a fireplace, several space heaters, and a laser printer. Driving resulted in moderate exposures averaging about 30,000 particles/cm³ in each of two cars driven on 17 trips on major highways on the East and West Coasts. Most of the restaurants visited maintained consistently high levels of 50,000-200,000 particles/cm³ for the entire length of the meal. The indoor/outdoor ratios of size-resolved UFP were much lower than for PM₂.₅ or PM₁₀, suggesting that outdoor UFP have difficulty in penetrating a home. This in turn implies that outdoor concentrations of UFP have only a moderate effect on personal exposures if indoor sources are present. A time-weighted scenario suggests that for typical suburban nonsmoker lifestyles, indoor sources provide about 47% and outdoor sources about 36% of total daily UFP exposure and in-vehicle exposures add the remainder (17%). However, the effect of one smoker in the home results in an overwhelming increase in the importance of indoor sources (77% of the total).

  14. Translocation of Inhaled Ultrafine Manganese Oxide Particles to the Central Nervous System

    PubMed Central

    Elder, Alison; Gelein, Robert; Silva, Vanessa; Feikert, Tessa; Opanashuk, Lisa; Carter, Janet; Potter, Russell; Maynard, Andrew; Ito, Yasuo; Finkelstein, Jacob; Oberdörster, Günter

    2006-01-01

    Background Studies in monkeys with intranasally instilled gold ultrafine particles (UFPs; < 100 nm) and in rats with inhaled carbon UFPs suggested that solid UFPs deposited in the nose travel along the olfactory nerve to the olfactory bulb. Methods To determine if olfactory translocation occurs for other solid metal UFPs and assess potential health effects, we exposed groups of rats to manganese (Mn) oxide UFPs (30 nm; ~ 500 μg/m3) with either both nostrils patent or the right nostril occluded. We analyzed Mn in lung, liver, olfactory bulb, and other brain regions, and we performed gene and protein analyses. Results After 12 days of exposure with both nostrils patent, Mn concentrations in the olfactory bulb increased 3.5-fold, whereas lung Mn concentrations doubled; there were also increases in striatum, frontal cortex, and cerebellum. Lung lavage analysis showed no indications of lung inflammation, whereas increases in olfactory bulb tumor necrosis factor-α mRNA (~ 8-fold) and protein (~ 30-fold) were found after 11 days of exposure and, to a lesser degree, in other brain regions with increased Mn levels. Macrophage inflammatory protein-2, glial fibrillary acidic protein, and neuronal cell adhesion molecule mRNA were also increased in olfactory bulb. With the right nostril occluded for a 2-day exposure, Mn accumulated only in the left olfactory bulb. Solubilization of the Mn oxide UFPs was < 1.5% per day. Conclusions We conclude that the olfactory neuronal pathway is efficient for translocating inhaled Mn oxide as solid UFPs to the central nervous system and that this can result in inflammatory changes. We suggest that despite differences between human and rodent olfactory systems, this pathway is relevant in humans. PMID:16882521

  15. Particle Number Concentrations for HI-SCALE Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hering, Susanne V

    In support of the Holistic Interactions of Shallow Clouds, Aerosols, and Ecosystems (HI-SCALE) project to study new particle formation in the atmosphere, a pair of custom water condensation particle counters were provided to the second intensive field campaign, from mid-August through mid-September 2017, at the U.S. Department of Energy Southern Great Plains Atmospheric Radiation Measurement (ARM) Climate Research Facility observatory. These custom instruments were developed by Aerosol Dynamics, Inc. (Hering et al. 2017) to detect particles into the nanometer size range. Referred to as “versatile water condensation particle counter (vWCPC)”, they are water-based, laminar-flow condensational growth instruments whose lower particlemore » size threshold can be set based on user-selected operating temperatures. For HI-SCALE, the vWCPCs were configured to measure airborne particle number concentrations in the size range from approximately 2nm to 2μm. Both were installed in the particle sizing system operated by Chongai Kuang of Brookhaven National Laboratory (BNL). One of these was operated in parallel to a TSI Model 3776, upstream of the mobility particle sizing system, to measure total ambient particle concentrations. The airborne particle concentration data from this “total particle number vWCPC” (Ntot-vWCPC) system has been reported to the ARM database. The data are reported with one-second resolution. The second vWCPC was operated in parallel with the BNL diethylene glycol instrument to count particles downstream of a separate differential mobility size analyzer. Data from this “DMA-vWCPC” system was logged by BNL, and will eventually be provided by that laboratory.« less

  16. High efficiency cabin air filter in vehicles reduces drivers' roadway particulate matter exposures and associated lipid peroxidation

    PubMed Central

    Shu, Shi; Lin, Yan; She, Jianwen; Ip, Ho Sai Simon; Qiu, Xinghua; Zhu, Yifang

    2017-01-01

    Commuters who spend long hours on roads are exposed to high levels of traffic related air pollutants (TRAPs). Despite some well-known multiple adverse effects of TRAPs on human health, limited studies have focused on mitigation strategies to reduce these effects. In this study, we measured fine particulate matter (PM2.5) and ultrafine particle (UFP) concentrations inside and outside 17 taxis simultaneously while they were driven on roadways. The drivers’ urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and malondialdehyde (MDA) concentrations just before and right after the driving tests were also determined. Data were collected under three driving conditions (i.e. no mitigation (NM), window closed (WC), and window closed plus using high efficiency cabin air filters (WC+HECA)) for each taxi and driver. The results show that, compared to NM, the WC+HECA reduced in-cabin PM2.5 and UFP concentrations, by 37% and 47% respectively (p < 0.05), whereas the reductions on PAH exposures were insignificant. Although nonsignificant, a reduction of 17% was also observed in the drivers’ urinary MDA under WC+HECA. The MDA concentrations were found to be significantly associated with the in-cabin PM2.5 and UFP concentrations, suggesting the reduction of the drivers’ lipid peroxidation can be at least partially attributed to the PM2.5 and UFP reduction by WC+HECA. Overall, these results suggest HECA filters have potential to reduce particle levels inside taxis and protect drivers’ health. PMID:29176859

  17. High efficiency cabin air filter in vehicles reduces drivers' roadway particulate matter exposures and associated lipid peroxidation.

    PubMed

    Yu, Nu; Shu, Shi; Lin, Yan; She, Jianwen; Ip, Ho Sai Simon; Qiu, Xinghua; Zhu, Yifang

    2017-01-01

    Commuters who spend long hours on roads are exposed to high levels of traffic related air pollutants (TRAPs). Despite some well-known multiple adverse effects of TRAPs on human health, limited studies have focused on mitigation strategies to reduce these effects. In this study, we measured fine particulate matter (PM2.5) and ultrafine particle (UFP) concentrations inside and outside 17 taxis simultaneously while they were driven on roadways. The drivers' urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and malondialdehyde (MDA) concentrations just before and right after the driving tests were also determined. Data were collected under three driving conditions (i.e. no mitigation (NM), window closed (WC), and window closed plus using high efficiency cabin air filters (WC+HECA)) for each taxi and driver. The results show that, compared to NM, the WC+HECA reduced in-cabin PM2.5 and UFP concentrations, by 37% and 47% respectively (p < 0.05), whereas the reductions on PAH exposures were insignificant. Although nonsignificant, a reduction of 17% was also observed in the drivers' urinary MDA under WC+HECA. The MDA concentrations were found to be significantly associated with the in-cabin PM2.5 and UFP concentrations, suggesting the reduction of the drivers' lipid peroxidation can be at least partially attributed to the PM2.5 and UFP reduction by WC+HECA. Overall, these results suggest HECA filters have potential to reduce particle levels inside taxis and protect drivers' health.

  18. Impacts of freeway traffic conditions on in-vehicle exposure to ultrafine particulate matter

    NASA Astrophysics Data System (ADS)

    Bigazzi, Alexander Y.; Figliozzi, Miguel A.

    2012-12-01

    There is evidence of adverse health impacts from human exposure to traffic-related ultrafine particulate matter pollution. As more commuters are spending a significant portion of their daily routine inside vehicles, it is increasingly relevant to study exposure levels to harmful pollutants inside the vehicle microenvironment. This study is one of the first research efforts to combine detailed freeway traffic data (at 20 s intervals) and in-vehicle ultrafine particulate (UFP) exposure data under varying vehicle ventilation conditions. Results show that due to negative correlation between traffic speed and density, traffic states have a small but significant impact on in-vehicle UFP concentrations, highest in high traffic flow-high speed conditions or in high traffic density-low speed conditions. Vehicle cabin barrier effects are the primary determinant of in-vehicle exposure concentrations, providing 15% protection with the windows down, 47% protection with the windows up and the vent open, and 83-90% protection with the windows up and the vent closed (more with the air conditioning on). Unique results from this study include the dominance of ventilation over traffic effects on UFP and the non-linear relationships between traffic variables and UFP concentrations. The results of this research have important implications for exposure modeling and potential exposure mitigation strategies.

  19. Instrument comparison for Aerosolized Titanium Dioxide

    NASA Astrophysics Data System (ADS)

    Ranpara, Anand

    Recent toxicological studies have shown that the surface area of ultrafine particles (UFP i.e., particles with diameters less than 0.1 micrometer) has a stronger correlation with adverse health effects than does mass of these particles. Ultrafine titanium dioxide (TiO2) particles are widely used in industry, and their use is associated with adverse health outcomes, such as micro vascular dysfunctions and pulmonary damages. The primary aim of this experimental study was to compare a variety of laboratory and industrial hygiene (IH) field study instruments all measuring the same aerosolized TiO2. The study also observed intra-instrument variability between measurements made by two apparently identical devices of the same type of instrument placed side-by-side. The types of instruments studied were (1) DustTrak(TM) DRX, (2) Personal Data RAMs(TM) (PDR), (3) GRIMM, (4) Diffusion charger (DC) and (5) Scanning Mobility Particle Sizer (SMPS). Two devices of each of the four IH field study instrument types were used to measure six levels of mass concentration of fine and ultrafine TiO2 aerosols in controlled chamber tests. Metrics evaluated included real-time mass, active surface area and number/geometric surface area distributions, and off-line gravimetric mass and morphology on filters. DustTrak(TM) DRXs and PDRs were used for mass concentration measurements. DCs were used for active surface area concentration measurements. GRIMMs were used for number concentration measurements. SMPS was used for inter-instrument comparisons of surface area and number concentrations. The results indicated that two apparently identical devices of each DRX and PDR were statistically not different with each other for all the trials of both the sizes of powder (p < 5%). Mean difference between mass concentrations measured by two DustTrak DRX devices was smaller than that measured by two PDR devices. DustTrak DRX measurements were closer to the reference method, gravimetric mass concentration

  20. Health risks caused by short term exposure to ultrafine particles generated by residential wood combustion: a case study of Temuco, Chile.

    PubMed

    Díaz-Robles, Luis A; Fu, Joshua S; Vergara-Fernández, Alberto; Etcharren, Pablo; Schiappacasse, Luis N; Reed, Gregory D; Silva, María P

    2014-05-01

    Temuco is one of the most highly wood smoke polluted cities in Chile; however, there is scarce evidence of respiratory morbidity due to fine particulate matter. We aimed to estimate the relationship between daily concentration of ultrafine particles (UFP), with an aerodynamic diameter ≤ 0.1 μm, and outpatient visits for respiratory illness at medical care centers of Temuco, Chile, from August the 20th, 2009 to June the 30th, 2011. The Air Pollution Health Effects European Approach (APHEA2) protocol was followed, and a multivariate semi-parametric Poisson regression model was fitted with GAM techniques using R-Project statistical package; controlling for trend, seasonality, and confounders. The daily UFP were measured by a MOUDI NR-110 sampler. We found that results of the statistical analyses show significant associations between UFP and respiratory outpatient visits, with the elderly (population ≥ 65 years), being the group that presented the greatest risk. An interquartile increase of 4.73 μg/m(3) in UFP (lag 5 days) was associated with respiratory outpatient visits with a relative risk (RR) of 1.1458 [95% CI (1.0497-1.2507)] for the elderly. These results show novel findings regarding the relevance of daily UFP concentrations and health risk, especially for susceptible population in a wood smoke polluted city. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Time evolution of atmospheric particle number concentration during high-intensity pyrotechnic events

    NASA Astrophysics Data System (ADS)

    Crespo, Javier; Yubero, Eduardo; Nicolás, Jose F.; Caballero, Sandra; Galindo, Nuria

    2014-10-01

    The Mascletàs are high-intensity pyrotechnic events, typical of eastern Spanish festivals, in which thousands of firecrackers are burnt at ground level in an intense, short-time (<8 min) deafening spectacle that generates short-lived, thick aerosol clouds. In this study, the impact of such events on air quality has been evaluated by means of particle number concentration measurements performed close to the venue during the June festival in Alicante (southeastern Spain). Peak concentrations and dilution times observed throughout the Mascletàs have been compared to those measured when conventional aerial fireworks were launched 2 km away from the monitoring site. The impact of the Mascletàs on the total number concentration of particles larger than 0.3 μm was higher (maximum ∼2·104 cm-3) than that of fireworks (maximum ∼2·103 cm-3). The effect of fireworks depended on whether the dominant meteorological conditions favoured the transport of the plume to the measurement location. However, the time required for particle concentrations to return to background levels is longer and more variable for firework displays (minutes to hours) than for the Mascletàs (<25 min).

  2. Impact of atmospheric particulate matter pollutants to IAQ of airport terminal buildings: A first field study at Tianjin Airport, China

    NASA Astrophysics Data System (ADS)

    Ren, Jianlin; Cao, Xiaodong; Liu, Junjie

    2018-04-01

    Passengers usually spend hours in the airport terminal buildings waiting for their departure. During the long waiting period, ambient fine particles (PM2.5) and ultrafine particles (UFP) generated by airliners may penetrate into terminal buildings through open doors and the HVAC system. However, limited data are available on passenger exposure to particulate pollutants in terminal buildings. We conducted on-site measurements on PM2.5 and UFP concentration and the particle size distribution in the terminal building of Tianjin Airport, China during three different seasons. The results showed that the PM2.5 concentrations in the terminal building were considerably larger than the values guided by Chinese standard and WHO on all of the tested seasons, and the conditions were significantly affected by the outdoor air (Spearman test, p < 0.01). The indoor/outdoor PM2.5 ratios (I/O) ranged from 0.67 to 0.84 in the arrival hall and 0.79 to 0.96 in the departure hall. The particle number concentration in the terminal building presented a bi-modal size distribution, with one mode being at 30 nm and another mode at 100 nm. These results were totally different from the size distribution measured in a normal urban environment. The total UFP exposure during the whole waiting period (including in the terminal building and airliner cabin) of a passenger is approximately equivalent to 11 h of exposure to normal urban environments. This study is expected to contribute to the improvement of indoor air quality and health of passengers in airport terminal buildings.

  3. Robustness of intra urban land-use regression models for ultrafine particles and black carbon based on mobile monitoring.

    PubMed

    Kerckhoffs, Jules; Hoek, Gerard; Vlaanderen, Jelle; van Nunen, Erik; Messier, Kyle; Brunekreef, Bert; Gulliver, John; Vermeulen, Roel

    2017-11-01

    Land-use regression (LUR) models for ultrafine particles (UFP) and Black Carbon (BC) in urban areas have been developed using short-term stationary monitoring or mobile platforms in order to capture the high variability of these pollutants. However, little is known about the comparability of predictions of mobile and short-term stationary models and especially the validity of these models for assessing residential exposures and the robustness of model predictions developed in different campaigns. We used an electric car to collect mobile measurements (n = 5236 unique road segments) and short-term stationary measurements (3 × 30min, n = 240) of UFP and BC in three Dutch cities (Amsterdam, Utrecht, Maastricht) in 2014-2015. Predictions of LUR models based on mobile measurements were compared to (i) measured concentrations at the short-term stationary sites, (ii) LUR model predictions based on short-term stationary measurements at 1500 random addresses in the three cities, (iii) externally obtained home outdoor measurements (3 × 24h samples; n = 42) and (iv) predictions of a LUR model developed based upon a 2013 mobile campaign in two cities (Amsterdam, Rotterdam). Despite the poor model R 2 of 15%, the ability of mobile UFP models to predict measurements with longer averaging time increased substantially from 36% for short-term stationary measurements to 57% for home outdoor measurements. In contrast, the mobile BC model only predicted 14% of the variation in the short-term stationary sites and also 14% of the home outdoor sites. Models based upon mobile and short-term stationary monitoring provided fairly high correlated predictions of UFP concentrations at 1500 randomly selected addresses in the three Dutch cities (R 2 = 0.64). We found higher UFP predictions (of about 30%) based on mobile models opposed to short-term model predictions and home outdoor measurements with no clear geospatial patterns. The mobile model for UFP was stable over different settings as

  4. The global impact of mineral dust on cloud droplet number concentration

    NASA Astrophysics Data System (ADS)

    Karydis, V.; Tsimpidi, A.; Bacer, S.; Pozzer, A.; Nenes, A.; Lelieveld, J.

    2016-12-01

    This study assesses the importance of mineral dust for cloud droplet formation by taking into account i) the adsorption of water on the surface of insoluble dust particles, ii) the coating of soluble material on the surface of mineral particles which augments their cloud condensation nuclei activity, and iii) the effect of dust on the inorganic aerosol concentrations through thermodynamic interactions with mineral cations. Simulations are carried out with the EMAC chemistry climate model that calculates the global atmospheric aerosol composition using the ISORROPIA-II thermodynamic equilibrium model and considers the gas phase interactions with K+-Ca2+-Mg2+-NH4+-Na+-SO42-NO3-Cl-H2O particle components. Emissions of the inert mineral dust and the reactive dust aerosol components are calculated online by taking into account the soil particle size distribution and chemical composition of different deserts worldwide (Karydis et al., 2016). We have implemented the "unified dust activation parameterization" (Kumar et al., 2011; Karydis et al., 2011) to calculate the droplet number concentration by taking into account the inherent hydrophilicity from adsorption and the acquired hygroscopicity from soluble salts by dust particles. Our simulations suggest that mineral dust significantly increases the cloud droplet number concentration (CDNC) over the main deserts and the adjacent oceans. However, over polluted areas the CDNC decreases significantly in the presence of dust. Furthermore, we investigate the role of adsorption activation of insoluble aerosols and the mineral dust thermodynamic interactions with inorganic anions on the cloud droplet formation. The CDNC sensitivity to the emission load, chemical composition, and inherent hydrophilicity of mineral dust is also tested. ReferencesKarydis, et al. (2011). "On the effect of dust particles on global cloud condensation nuclei and cloud droplet number." J. Geophys. Res. Atmos. 116. Karydis, et al. (2016). "Effects of

  5. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea.

    PubMed

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-12-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3-0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01-0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1-10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Physical stability of R-(+)-Limonene emulsions stabilized by Ulva fasciata algae polysaccharide.

    PubMed

    Shao, Ping; Ma, Huiling; Qiu, Qiang; Jing, Weiping

    2016-11-01

    The physical stability of R-(+)-Limonene emulsions stabilized by Ulva fasciata polysaccharide (UFP) was investigated in this study. Emulsion physical stability was evaluated under different polysaccharide concentrations (1%-5%, wt/wt) and pH values (3.0-11.0). The stability of R-(+)-Limonene emulsions was demonstrated by droplet size distribution, rheological properties, zeta potential and visual phase separation. R-(+)-Limonene emulsions displayed monomodal droplet size distributions, high absolute values of zeta potential and good storage stability when 3% (wt/wt) UFP was used. The rheological properties and stability of R-(+)-Limonene emulsions appeared to be dependent on polysaccharide concentration. The emulsion stability was impacted by pH. Higher zeta potential (-52.6mV) and smaller mean droplet diameter (2.45μm) were achieved in neutral liquid environment (pH 7.0). Extreme acidity caused the flocculation of emulsions, which was manifested as phase separation, while emulsions were quite stable in an alkaline environment. Through comparing the stabilities of emulsions stabilized by different emulsifiers (i.e. UFP, GA and Gelatin), the result suggested that UFP was the best emulsifying agent among them. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Ambient ultrafine particles provide a strong adjuvant effect in the secondary immune response: implication for traffic-related asthma flares

    PubMed Central

    Li, Ning; Harkema, Jack R.; Lewandowski, Ryan P.; Wang, Meiying; Bramble, Lori A.; Gookin, Glenn R.; Ning, Zhi; Kleinman, Michael T.; Sioutas, Constantinos

    2010-01-01

    We have previously demonstrated that intranasal administration of ambient ultrafine particles (UFP) acts as an adjuvant for primary allergic sensitization to ovalbumin (OVA) in Balb/c mice. It is important to find out whether inhaled UFP exert the same effect on the secondary immune response as a way of explaining asthma flares in already-sensitized individuals due to traffic exposure near a freeway. The objective of this study is to determine whether inhalation exposure to ambient UFP near an urban freeway could enhance the secondary immune response to OVA in already-sensitized mice. Prior OVA-sensitized animals were exposed to concentrated ambient UFP at the time of secondary OVA challenge in our mobile animal laboratory in Los Angeles. OVA-specific antibody production, airway morphometry, allergic airway inflammation, cytokine gene expression, and oxidative stress marker were assessed. As few as five ambient UFP exposures were sufficient to promote the OVA recall immune response, including generating allergic airway inflammation in smaller and more distal airways compared with the adjuvant effect of intranasally instilled UFP on the primary immune response. The secondary immune response was characterized by the T helper 2 and IL-17 cytokine gene expression in the lung. In summary, our results demonstrated that inhalation of prooxidative ambient UFP could effectively boost the secondary immune response to an experimental allergen, indicating that vehicular traffic exposure could exacerbate allergic inflammation in already-sensitized subjects. PMID:20562226

  8. Laboratory Tests on Post-Filtration Precipitation in the WTP Pretreatment Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan (Barnes et al. 2006). The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, andmore » slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF).« less

  9. Exposure to particle number, surface area and PM concentrations in pizzerias

    NASA Astrophysics Data System (ADS)

    Buonanno, G.; Morawska, L.; Stabile, L.; Viola, A.

    2010-10-01

    The aim of this work was to quantify exposure to particles emitted by wood-fired ovens in pizzerias. Overall, 15 microenvironments were chosen and analyzed in a 14-month experimental campaign. Particle number concentration and distribution were measured simultaneously using a Condensation Particle Counter (CPC), a Scanning Mobility Particle Sizer (SMPS), an Aerodynamic Particle Sizer (APS). The surface area and mass distributions and concentrations, as well as the estimation of lung deposition surface area and PM 1 were evaluated using the SMPS-APS system with dosimetric models, by taking into account the presence of aggregates on the basis of the Idealized Aggregate (IA) theory. The fraction of inhaled particles deposited in the respiratory system and different fractions of particulate matter were also measured by means of a Nanoparticle Surface Area Monitor (NSAM) and a photometer (DustTrak DRX), respectively. In this way, supplementary data were obtained during the monitoring of trends inside the pizzerias. We found that surface area and PM 1 particle concentrations in pizzerias can be very high, especially when compared to other critical microenvironments, such as the transport hubs. During pizza cooking under normal ventilation conditions, concentrations were found up to 74, 70 and 23 times higher than background levels for number, surface area and PM 1, respectively. A key parameter is the oven shape factor, defined as the ratio between the size of the face opening in respect to the diameter of the semicircular oven door, and particular attention must also be paid to hood efficiency.

  10. Personal exposure to particulate matter in commuters using different transport modes (bus, bicycle, car and subway) in an assigned route in downtown Santiago, Chile.

    PubMed

    Suárez, Liliana; Mesías, Stephanie; Iglesias, Verónica; Silva, Claudio; Cáceres, Dante D; Ruiz-Rudolph, Pablo

    2014-05-01

    The objective of this study was to compare personal exposure to particulate matter (fine and ultrafine particles) in commuters using different transport modes (bicycle, bus, car and subway) in a busy, assigned route in downtown Santiago, Chile. Volunteers carrying personal samplers completed scheduled commutes during the morning rush hours, while central site measurements were conducted in parallel. A total of 137 valid commutes were assessed. The impact of central site, traffic and other variables was explored with regression models. PM2.5 personal concentrations were equal to or slightly above central site measurements, while UFP personal concentrations were above them. Regression models showed impacts of both background levels and traffic emissions on personal PM2.5 and UFP exposure. Traffic impacts varied with transport modes. Estimates of traffic impacts on personal PM2.5 exposure were 2.0, 13.0, 16.9 and 17.5 μg m(-3), for car, bicycle, subway and bus, respectively; while for UFP exposure were 8400, 16 200, 25 600 and 30 100 counts per cm(3), for subway, car, bicycle and bus, respectively. After controlling the central site and transport mode, higher temperatures increased PM2.5 exposure and decreased UFP ones, while the wind direction affected UFP personal exposure. In conclusion, we found significant impacts of both central site background measurements and traffic emissions on personal exposure of volunteer commuters in an assigned route in Santiago, with impacts varying with transport modes.

  11. Exposure to ultrafine particles in different transport modes in the city of Rome.

    PubMed

    Grana, Mario; Toschi, Nicola; Vicentini, Laura; Pietroiusti, Antonio; Magrini, Andrea

    2017-09-01

    There is evidence of adverse health impacts from human exposure to particulate air pollution, including increased rates of respiratory and cardiovascular illness, hospitalizations, and pre-mature mortality. Most recent hypotheses assign an important role to ultrafine particles (UFP) (<0.1 μm) and to associated transition metals (in particular Fe). In a large city like Rome, where many active people spend more than one hour per day in private or public transportation, it may be important to evaluate the level of exposure to harmful pollutants which occurs during urban travelling. In this context, the aim of this work was to examine the relative contribution of different transport modes to total daily exposure. We performed experimental measurements during both morning and evening traffic peak hours throughout the winter season (December 2013-March 2014), for a total of 98 trips. Our results suggest that the lowest UFP exposures are experienced by underground train commuters, with an average number concentration of 14 134 cm -3 , and are largely a reflection of the routes being at greater distance from vehicular traffic. Motorcyclists experienced significantly higher average concentrations (73 168 cm -3 ) than all other exposure classes, and this is most likely a result of the presence of high-concentration and short-duration peaks which do not occur when the same routes are traveled by car. UFP concentrations in subway train environments were found to be comparable to urban background levels. Still, in underground trains we found the highest values of PM 10 mass concentration with a maximum value of 422 μg/m 3 . PM 10 concentration in trains was found to be four and two times higher than what was measured in car and motorbike trips, respectively. Transport mode contribution to total integrated UFP daily exposure was found to be 16.3%-20.9% while travelling by car, 28.7% for motorbike trips, and 8.7% for subway trips. Due to lower exposure times, commuting by

  12. Size-segregated particle number concentrations and respiratory emergency room visits in Beijing, China.

    PubMed

    Leitte, Arne Marian; Schlink, Uwe; Herbarth, Olf; Wiedensohler, Alfred; Pan, Xiao-Chuan; Hu, Min; Richter, Matthia; Wehner, Birgit; Tuch, Thomas; Wu, Zhijun; Yang, Minjuan; Liu, Liqun; Breitner, Susanne; Cyrys, Josef; Peters, Annette; Wichmann, H-Erich; Franck, Ulrich

    2011-04-01

    The link between concentrations of particulate matter (PM) and respiratory morbidity has been investigated in numerous studies. The aim of this study was to analyze the role of different particle size fractions with respect to respiratory health in Beijing, China. Data on particle size distributions from 3 nm to 1 µm; PM10 (PM ≤ 10 µm), nitrogen dioxide (NO(2)), and sulfur dioxide concentrations; and meteorologic variables were collected daily from March 2004 to December 2006. Concurrently, daily counts of emergency room visits (ERV) for respiratory diseases were obtained from the Peking University Third Hospital. We estimated pollutant effects in single- and two-pollutant generalized additive models, controlling for meteorologic and other time-varying covariates. Time-delayed associations were estimated using polynomial distributed lag, cumulative effects, and single lag models. Associations of respiratory ERV with NO(2) concentrations and 100-1,000 nm particle number or surface area concentrations were of similar magnitude-that is, approximately 5% increase in respiratory ERV with an interquartile range increase in air pollution concentration. In general, particles < 50 nm were not positively associated with ERV, whereas particles 50-100 nm were adversely associated with respiratory ERV, both being fractions of ultrafine particles. Effect estimates from two-pollutant models were most consistent for NO(2). Present levels of air pollution in Beijing were adversely associated with respiratory ERV. NO(2) concentrations seemed to be a better surrogate for evaluating overall respiratory health effects of ambient air pollution than PM(10) or particle number concentrations in Beijing.

  13. Regular expansion solutions for small Peclet number heat or mass transfer in concentrated two-phase particulate systems

    NASA Technical Reports Server (NTRS)

    Yaron, I.

    1974-01-01

    Steady state heat or mass transfer in concentrated ensembles of drops, bubbles or solid spheres in uniform, slow viscous motion, is investigated. Convective effects at small Peclet numbers are taken into account by expanding the nondimensional temperature or concentration in powers of the Peclet number. Uniformly valid solutions are obtained, which reflect the effects of dispersed phase content and rate of internal circulation within the fluid particles. The dependence of the range of Peclet and Reynolds numbers, for which regular expansions are valid, on particle concentration is discussed.

  14. Contribution from indoor sources to particle number and mass concentrations in residential houses

    NASA Astrophysics Data System (ADS)

    He, Congrong; Morawska, Lidia; Hitchins, Jane; Gilbert, Dale

    As part of a large study investigating indoor air in residential houses in Brisbane, Australia, the purpose of this work was to quantify emission characteristics of indoor particle sources in 15 houses. Submicrometer particle number and approximation of PM 2.5 concentrations were measured simultaneously for more than 48 h in the kitchen of all the houses by using a condensation particle counter (CPC) and a photometer (DustTrak), respectively. In addition, characterizations of particles resulting from cooking conducted in an identical way in all the houses were measured by using a scanning mobility particle sizer (SMPS), an aerodynamic particle sizer (APS) and a DustTrak. All the events of elevated particle concentrations were linked to indoor activities using house occupants diary entries, and catalogued into 21 different types of indoor activities. This enabled quantification of the effect of indoor sources on indoor particle concentrations as well as quantification of emission rates from the sources. For example, the study found that frying, grilling, stove use, toasting, cooking pizza, cooking, candle vaporizing eucalyptus oil and fan heater use, could elevate the indoor submicrometer particle number concentration levels by more than five times, while PM 2.5 concentrations could be up to 3, 30 and 90 times higher than the background levels during smoking, frying and grilling, respectively.

  15. Comparing the impact of ultrafine particles from petrodiesel and biodiesel combustion to bacterial metabolism by targeted HPLC-MS/MS metabolic profiling.

    PubMed

    Zhong, Fanyi; Xu, Mengyang; Schelli, Katie; Rutowski, Joshua; Holmén, Britt A; Zhu, Jiangjiang

    2017-08-01

    Alterations of gut bacterial metabolism play an important role in their host metabolism, and can result in diseases such as obesity and diabetes. While many factors were discovered influencing the gut bacterial metabolism, exposure to ultrafine particles (UFPs) from engine combustions were recently proposed to be a potential risk factor for the perturbation of gut bacterial metabolism, and consequentially to obesity and diabetes development. This study focused on evaluation of how UFPs from diesel engine combustions impact gut bacterial metabolism. We hypothesize that UFPs from different type of diesel (petrodiesel vs. biodiesel) will both impact bacterial metabolism, and the degree of impact is also diesel type-dependent. Targeted metabolic profiling of 221 metabolites were applied to three model gut bacteria in vitro, Streptococcus salivarius, Lactobacillus acidophilus and Lactobacillus fermentum. UFPs from two types of fuels, petrodiesel (B0) and a biodiesel blend (B20: 20% soy biodiesel/80% B0 by volume), were exposed to the bacteria and their metabolic changes were compared. For each bacterial strain, metabolites with significantly changed abundance were observed in both perturbations, and all three strains have increased number of altered metabolites detected from B20 UFPs perturbation in comparison to B0 UFPs. Multivariate statistical analysis further confirmed that the metabolic profiles were clearly different between testing groups. Metabolic pathway analyses also demonstrated several important metabolic pathways, including pathways involves amino acids biosynthesis and sugar metabolism, were significantly impacted by UFPs exposure. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A work group report on ultrafine particles (American Academy of Allergy, Asthma & Immunology): Why ambient ultrafine and engineered nanoparticles should receive special attention for possible adverse health outcomes in human subjects.

    PubMed

    Li, Ning; Georas, Steve; Alexis, Neil; Fritz, Patricia; Xia, Tian; Williams, Marc A; Horner, Elliott; Nel, Andre

    2016-08-01

    Ultrafine particles (UFPs) are airborne particulates of less than 100 nm in aerodynamic diameter. Examples of UFPs are diesel exhaust particles, products of cooking, heating, and wood burning in indoor environments, and, more recently, products generated through the use of nanotechnology. Studies have shown that ambient UFPs have detrimental effects on both the cardiovascular and respiratory systems, including a higher incidence of atherosclerosis and exacerbation rate of asthma. UFPs have been found to alter in vitro and in vivo responses of the immune system to allergens and can also play a role in allergen sensitization. The inflammatory properties of UFPs can be mediated by a number of different mechanisms, including the ability to produce reactive oxygen species, leading to the generation of proinflammatory cytokines and airway inflammation. In addition, because of their small size, UFPs also have unique distribution characteristics in the respiratory tree and circulation and might be able to alter cellular function in ways that circumvent normal signaling pathways. Additionally, UFPs can penetrate intracellularly and potentially cause DNA damage. The recent advances in nanotechnology, although opening up new opportunities for the advancement of technology and medicine, could also lead to unforeseen adverse health effects in exposed human subjects. Further research is needed to clarify the safety of nanoscale particles, as well as the elucidation of the possible beneficial use of these particulates to treat disease. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  17. Factors controlling particle number concentration and size at metro stations

    NASA Astrophysics Data System (ADS)

    Reche, C.; Moreno, T.; Martins, V.; Minguillón, M. C.; Jones, T.; de Miguel, E.; Capdevila, M.; Centelles, S.; Querol, X.

    2017-05-01

    An extensive air quality campaign was performed at differently designed station platforms in the Barcelona metro system, aiming to investigate the factors governing airborne particle number (N) concentrations and their size distributions. The study of the daily trends of N concentrations by different size ranges shows that concentrations of N0.3-10 are closely related with the schedule of the metro service. Conversely, the hourly variation of N0.007-10 (mainly composed of ultrafine particles) could be partly governed by the entrance of particles from outdoor emissions through mechanical ventilation. Measurements under different ventilation settings at three metro platforms reveal that the effect on air quality linked to changes in the tunnel ventilation depends on the station design. Night-time maintenance works in tunnels are frequent activities in the metro system; and after intense prolonged works, these can result in higher N concentrations at platforms during the following metro operating hours (by up to 30%), this being especially evident for N1-10. Due to the complex mixture of factors controlling N, together with the differences in trends recorded for particles within different size ranges, developing an air quality strategy at metro systems is a great challenge. When compared to street-level urban particles concentrations, the priority in metro air quality should be dealing with particles coarser than 0.3 μm. In fact, the results suggest that at narrow platforms served by single-track tunnels the current forced tunnel ventilation during operating hours is less efficient in reducing coarse particles compared to fine.

  18. Ultrafine Particle Distribution and Chemical Composition Assessment during Military Operative Trainings

    PubMed Central

    Campagna, Marcello; Pilia, Ilaria; Marcias, Gabriele; Frattolillo, Andrea; Pili, Sergio; Bernabei, Manuele; d’Aloja, Ernesto; Cocco, Pierluigi; Buonanno, Giorgio

    2017-01-01

    (1) Background: The assessment of airborne particulate matter (PM) and ultrafine particles (UFPs) in battlefield scenarios is a topic of particular concern; (2) Methods: Size distribution, concentration, and chemical composition of UFPs during operative military training activities (target drone launches, ammunition blasting, and inert bomb impact) were investigated using an electric low-pressure impactor (ELPI+) and a scanning electron microscope (SEM), equipped with energy-dispersive spectroscopy (EDS); (3) Results: The median of UFPs, measured for all sampling periods and at variable distance from sources, was between 1.02 × 103 and 3.75 × 103 particles/cm3 for drone launches, between 3.32 × 103 and 15.4 × 103 particles/cm3 for the ammunition blasting and from 7.9 × 103 to 1.3 × 104 particles/cm3 for inert launches. Maximum peak concentrations, during emitting sources starting, were 75.5 × 106 and 17.9 × 106 particles/cm3, respectively. Particles from the drone launches were predominantly composed of silicon (Si), iron (Fe) and calcium (Ca), and those from the blasting campaigns by magnesium (Mg), sulphur (S), aluminum (Al), iron (Fe), barium (Ba) and silicon (Si); (4) Conclusions: The investigated sources produced UFPs with median values lower than other anthropogenic sources, and with a similar chemical composition. PMID:28556812

  19. Observations of high droplet number concentrations in Southern Ocean boundary layer clouds

    NASA Astrophysics Data System (ADS)

    Chubb, T.; Huang, Y.; Jensen, J.; Campos, T.; Siems, S.; Manton, M.

    2015-09-01

    Data from the standard cloud physics payload during the NSF/NCAR High-performance Instrumented Airborne Platform for Environmental Research (HIAPER) Pole-to-Pole Observations (HIPPO) campaigns provide a snapshot of unusual wintertime microphysical conditions in the boundary layer over the Southern Ocean. On 29 June 2011, the HIAPER sampled the boundary layer in a region of pre-frontal warm air advection between 58 and 48° S to the south of Tasmania. Cloud droplet number concentrations were consistent with climatological values in the northernmost profiles but were exceptionally high for wintertime in the Southern Ocean at 100-200 cm-3 in the southernmost profiles. Sub-micron (0.06concentrations for the southern profiles were up to 400 cm-3. Analysis of back trajectories and atmospheric chemistry observations revealed that while conditions in the troposphere were more typical of a clean remote ocean airmass, there was some evidence of continental or anthropogenic influence. However, the hypothesis of long range transport of continental aerosol fails to explain the magnitude of the aerosol and cloud droplet concentration in the boundary layer. Instead, the gale force surface winds in this case (wind speed at 167 m above sea level was >25 m s-1) were most likely responsible for production of sea spray aerosol which influenced the microphysical properties of the boundary layer clouds. The smaller size and higher number concentration of cloud droplets is inferred to increase the albedo of these clouds, and these conditions occur regularly, and are expected to increase in frequency, over windy parts of the Southern Ocean.

  20. Factors influencing variability in the infiltration of PM2.5 mass and its components

    NASA Astrophysics Data System (ADS)

    MacNeill, M.; Wallace, L.; Kearney, J.; Allen, R. W.; Van Ryswyk, K.; Judek, S.; Xu, X.; Wheeler, A.

    2012-12-01

    The infiltration of particles into homes can vary seasonally, between homes in a community and between communities. However, few studies have examined the day to day variability across multiple homes. We used continuous data collected from a 2-year (2005-2006) personal exposure study conducted in Windsor, ON to estimate daily infiltration factors (Finf) for fine particulate matter (PM2.5), Black Carbon (BC), and ultrafine particles (UFP) as well as the ambient personal exposure factor (Fpex) for PM2.5. In addition, the daily ambient and non-ambient generated components of indoor and personal concentrations were estimated. Median daily Finf estimates ranged from 0.26 to 0.36 across seasons for PM2.5; from 0.28 to 0.59 for BC; and from 0.15 to 0.26 for UFP. Median daily Fpex estimates ranged from 0.24 to 0.31 across seasons. Daily PM2.5 and UFP Finf and Fpex estimates were higher in summer than winter, although BC showed the opposite trend. Predictors of daily infiltration were typically related to window-opening behaviours, air conditioning, meteorological variables, and home age. In addition, use of electrostatic precipitators and stand alone air cleaners was associated with significantly reduced infiltration factors, indicating that these devices may provide a cost effective mechanism of reducing human exposures to particles of ambient origin. The majority of indoor PM2.5 (median 57-73%) and indoor BC (median 90-100%) was of ambient origin across seasons, while both personal PM2.5 and indoor UFPs had significant non-ambient contributions (median 60-65%). Factors that were found to increase non-ambient particle concentrations were typically related to cooking, candle use, supplemental heating, cleaning, and number of people in the home. Factors that were found to decrease non-ambient particle concentrations were open windows, and air cleaner use. This work has several implications to both epidemiologic studies and risk management. A better understanding of the

  1. Release of ultrafine particles from three simulated building processes

    NASA Astrophysics Data System (ADS)

    Kumar, Prashant; Mulheron, Mike; Som, Claudia

    2012-03-01

    Building activities are recognised to produce coarse particulate matter but less is known about the release of airborne ultrafine particles (UFPs; those below 100 nm in diameter). For the first time, this study has investigated the release of particles in the 5-560 nm range from three simulated building activities: the crushing of concrete cubes, the demolition of old concrete slabs, and the recycling of concrete debris. A fast response differential mobility spectrometer (Cambustion DMS50) was used to measure particle number concentrations (PNC) and size distributions (PNDs) at a sampling frequency of 10 Hz in a confined laboratory room providing controlled environment and near-steady background PNCs. The sampling point was intentionally kept close to the test samples so that the release of new UFPs during these simulated processes can be quantified. Tri-modal particle size distributions were recorded for all cases, demonstrating different peak diameters in fresh nuclei (<10 nm), nucleation (10-30 nm) and accumulation (30-300 nm) modes for individual activities. The measured background size distributions showed modal peaks at about 13 and 49 nm with average background PNCs 1.47 × 104 cm-3. These background modal peaks shifted towards the larger sizes during the work periods (i.e. actual experiments) and the total PNCs increased between 2 and 17 times over the background PNCs for different activities. After adjusting for background concentrations, the net release of PNCs during cube crushing, slab demolition, and `dry' and `wet' recycling events were measured as 0.77, 19.1, 22.7 and 1.76 (×104) cm-3, respectively. The PNDs were converted into particle mass concentrations (PMCs). While majority of new PNC release was below 100 nm (i.e. UFPs), the bulk of new PMC emissions were constituted by the particles over 100 nm; 95, 79, 73 and 90% of total PNCs, and 71, 92, 93 and 91% of total PMCs, for cube crushing, slab demolition, dry recycling and wet recycling

  2. A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway

    PubMed Central

    Padró-Martínez, Luz T.; Owusu, Emmanuel; Reisner, Ellen; Zamore, Wig; Simon, Matthew C.; Mwamburi, Mkaya; Brown, Carrie A.; Chung, Mei; Brugge, Doug; Durant, John L.

    2015-01-01

    Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a particle counter (measuring particle number concentration (PNC), a proxy for UFP) were installed in living rooms. Participants were exposed to filtered air for 21 days and unfiltered air for 21 days. Blood samples were collected and blood pressure measured at days 0, 21 and 42 after a 12-hour fasting period. Plasma was analyzed for high sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor necrosis factor alpha-receptor II (TNF-RII) and fibrinogen. PNC reductions ranging from 21% to 68% were recorded in 15 of the apartments. We observed no significant differences in blood pressure or three of the four biomarkers (hsCRP, fibrinogen, and TNF-RII) measured in participants after 21-day exposure to HEPA-filtered air compared to measurements after 21-day exposure to sham-filtered air. In contrast, IL-6 concentrations were significantly higher following HEPA filtration (0.668 pg/mL; CI = 0.465–0.959) compared to sham filtration. Likewise, PNC adjusted for time activity were associated with increasing IL-6 in 14- and 21-day moving averages, and PNC was associated with decreasing blood pressure in Lags 0, 1 and 2, and in a 3-day moving average. These negative associations were unexpected and could be due to a combination of factors including exposure misclassification, unsuccessful randomization (i.e., IL-6 and use of anti-inflammatory medicines), or uncontrolled confounding. Studies with greater reduction in UFP levels and larger sample sizes are needed. There also needs to be more complete assessment of resident time activity and of outdoor vs. indoor source contributions

  3. A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway.

    PubMed

    Padró-Martínez, Luz T; Owusu, Emmanuel; Reisner, Ellen; Zamore, Wig; Simon, Matthew C; Mwamburi, Mkaya; Brown, Carrie A; Chung, Mei; Brugge, Doug; Durant, John L

    2015-07-10

    Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a particle counter (measuring particle number concentration (PNC), a proxy for UFP) were installed in living rooms. Participants were exposed to filtered air for 21 days and unfiltered air for 21 days. Blood samples were collected and blood pressure measured at days 0, 21 and 42 after a 12-hour fasting period. Plasma was analyzed for high sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor necrosis factor alpha-receptor II (TNF-RII) and fibrinogen. PNC reductions ranging from 21% to 68% were recorded in 15 of the apartments. We observed no significant differences in blood pressure or three of the four biomarkers (hsCRP, fibrinogen, and TNF-RII) measured in participants after 21-day exposure to HEPA-filtered air compared to measurements after 21-day exposure to sham-filtered air. In contrast, IL-6 concentrations were significantly higher following HEPA filtration (0.668 pg/mL; CI = 0.465-0.959) compared to sham filtration. Likewise, PNC adjusted for time activity were associated with increasing IL-6 in 14- and 21-day moving averages, and PNC was associated with decreasing blood pressure in Lags 0, 1 and 2, and in a 3-day moving average. These negative associations were unexpected and could be due to a combination of factors including exposure misclassification, unsuccessful randomization (i.e., IL-6 and use of anti-inflammatory medicines), or uncontrolled confounding. Studies with greater reduction in UFP levels and larger sample sizes are needed. There also needs to be more complete assessment of resident time activity and of outdoor vs. indoor source contributions

  4. Indoor particulate pollution in fitness centres with emphasis on ultrafine particles.

    PubMed

    Slezakova, Klara; Peixoto, Cátia; Oliveira, Marta; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone

    2018-02-01

    Fitness centres (FC) represent a unique indoor microenvironment. Exercising on regular basis provides countless health benefits and improves overall well-being, but if these facilities have poor indoor air quality, the respective exercisers might be subjected to some adverse risks. Considering the limited existent data, this work aimed to evaluate particulate pollution (PM 10, PM 2.5 , and ultrafine particles - UFP) in indoor air of FC and to estimate the respective risks for occupants (both staff and exercising subjects). Sampling was conducted during 40 consecutive days of May-June 2014 in general fitness areas, studios and classrooms (for group activities) of four different fitness centres (FC1-FC4) situated within Oporto metropolitan area, Portugal. The results showed that across the four FC, PM 10 ranged between 5 and 1080 μg m -3 with median concentrations (15-43 μg m -3 ) fulfilling the limit (50 μg m -3 ) of Portuguese legislation in all FC. PM 2.5 (medians 5-37 μg m -3 ; range 5-777 μg m -3 ) exceeded thresholds of 25 μg m -3 at some FC, indicating potential risks for the respective occupants; naturally ventilated FC exhibited significantly higher PM ranges (p < 0.05). Similarly, UFPs (range 0.5-88.6 × 10 3 # cm -3 ) median concentrations were higher (2-3 times) at FC without controlled ventilation systems. UFP were approximately twice higher (p < 0.05) during the occupied periods (mean of 9.7 × 10 3 vs. 4.8 × 10 3 # cm -3 ) with larger temporal variations of UFP levels observed in general fitness areas than in classrooms and studios. Cardio activities (conducted in studios and classrooms) led to approximately twice the UFPs intakes than other types of exercising. These results indicate that even short-term physical activity (or more specifically its intensity) might strongly influence the daily inhalation dose. Finally, women exhibited 1.2 times higher UFPs intake than men thus suggesting the need for future gender

  5. Assessing the Cytotoxicity of Black Carbon As A Model for Ultrafine Anthropogenic Aerosol Across Human and Murine Cells: A Chronic Exposure Model of Nanosized Particulate Matter

    NASA Astrophysics Data System (ADS)

    Salinas, E.

    2015-12-01

    Combustion-derived nanomaterials or ultrafine (<1 μm) atmospheric aerosols are primarily products of anthropogenic activities, such as the burning of fossil fuels. Ultrafine particles (UFPs) can absorb other noxious pollutants including volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), toxic organic compounds, and heavy metals. The combination of high population density, meteorological conditions, and industrial productivity brings high levels of air pollution to the metropolitan area of El Paso, Texas, USA/ Ciudad Juarez, Chihuahua, Mexico, comprising the Paso del Norte air basin. A study conducted by scientists from the Research Triangle Park in North Carolina, analyzed sites adjacent to heavy-traffic highways in El Paso and elucidated higher UFP concentrations in comparison to previously published work exploring pollution and adverse health effects in the basin. UFPs can penetrate deep into the alveolar sacs of the lung, reaching distant alveolar sacs and inducing a series of immune responses that are detrimental to the body: evidence suggests that UFPs can also cross the alveolar-blood barrier and potentially endanger the body's immune response. The physical properties of UFPs and the dynamics of local atmospheric and topographical conditions indicate that emissions of nanosized carbonaceous aerosols could pose significant threats to biological tissues upon inhalation by local residents of the Paso del Norte. This study utilizes Black Carbon (BC) as a model for environmental UFPs and its effects on the immunological response. An in vitro approach is used to measure the ability of BC to promote cell death upon long-term exposure. Human epithelial lung cells (A549), human peripheral-blood monocytes (THP-1), murine macrophages (RAW264.7), and murine epithelial lung cells (LA-4) were treated with BC and assessed for metabolic activity after chronic exposure utilizing three distinct and independent cell viability assays. The cell viability

  6. Characterizing temporal changes of agricultural particulate matter number concentrations

    NASA Astrophysics Data System (ADS)

    Docekal, G. P.; Mahmood, R.; Larkin, G. P.; Silva, P. J.

    2017-12-01

    It is widely accepted among literature that particulate matter (PM) are of detriment to human health and the environment as a whole. These effects can vary depending on the particle size. This study examines PM size distributions and number concentrations at a poultry house. Despite much literature on PM concentrations at agricultural facilities, few studies have looked at the size distribution of particles at such facilities from the nucleation up through the coarse mode. Two optical particle counters (OPCs) were placed, one inside of a chicken house, and one on the outside of an exhaust fan to determine particle size distributions. In addition, a scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) sampled poultry house particles to give sizing information from a full size range of 10 nm - 20 mm. The data collected show several different types of events where observed size distributions changed. While some of these are due to expected dust generation events producing coarse mode particles, others suggest particle nucleation and accumulation events at the smaller size ranges that also occurred. The data suggest that agricultural facilities have an impact one the presence of PM in the environment beyond just generation of coarse mode dust. Data for different types of size distribution changes observed will be discussed.

  7. EFRT M12 Issue Resolution: Comparison of PEP and Bench-Scale Oxidative Leaching Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rapko, Brian M.; Brown, Christopher F.; Eslinger, Paul W.

    2009-08-14

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and is to be operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processesmore » using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to dissolve solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct steam injection to accelerate the leaching process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP1, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in UFP2, the slurry is concentrated to

  8. A land use regression model for ambient ultrafine particles in Montreal, Canada: A comparison of linear regression and a machine learning approach.

    PubMed

    Weichenthal, Scott; Ryswyk, Keith Van; Goldstein, Alon; Bagg, Scott; Shekkarizfard, Maryam; Hatzopoulou, Marianne

    2016-04-01

    Existing evidence suggests that ambient ultrafine particles (UFPs) (<0.1µm) may contribute to acute cardiorespiratory morbidity. However, few studies have examined the long-term health effects of these pollutants owing in part to a need for exposure surfaces that can be applied in large population-based studies. To address this need, we developed a land use regression model for UFPs in Montreal, Canada using mobile monitoring data collected from 414 road segments during the summer and winter months between 2011 and 2012. Two different approaches were examined for model development including standard multivariable linear regression and a machine learning approach (kernel-based regularized least squares (KRLS)) that learns the functional form of covariate impacts on ambient UFP concentrations from the data. The final models included parameters for population density, ambient temperature and wind speed, land use parameters (park space and open space), length of local roads and rail, and estimated annual average NOx emissions from traffic. The final multivariable linear regression model explained 62% of the spatial variation in ambient UFP concentrations whereas the KRLS model explained 79% of the variance. The KRLS model performed slightly better than the linear regression model when evaluated using an external dataset (R(2)=0.58 vs. 0.55) or a cross-validation procedure (R(2)=0.67 vs. 0.60). In general, our findings suggest that the KRLS approach may offer modest improvements in predictive performance compared to standard multivariable linear regression models used to estimate spatial variations in ambient UFPs. However, differences in predictive performance were not statistically significant when evaluated using the cross-validation procedure. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  9. Ultrafine Particle Distribution and Chemical Composition Assessment during Military Operative Trainings.

    PubMed

    Campagna, Marcello; Pilia, Ilaria; Marcias, Gabriele; Frattolillo, Andrea; Pili, Sergio; Bernabei, Manuele; d'Aloja, Ernesto; Cocco, Pierluigi; Buonanno, Giorgio

    2017-05-30

    (1) Background: The assessment of airborne particulate matter (PM) and ultrafine particles (UFPs) in battlefield scenarios is a topic of particular concern; (2) Methods: Size distribution, concentration, and chemical composition of UFPs during operative military training activities (target drone launches, ammunition blasting, and inert bomb impact) were investigated using an electric low-pressure impactor (ELPI+) and a scanning electron microscope (SEM), equipped with energy-dispersive spectroscopy (EDS); (3) Results: The median of UFPs, measured for all sampling periods and at variable distance from sources, was between 1.02 × 10³ and 3.75 × 10³ particles/cm³ for drone launches, between 3.32 × 10³ and 15.4 × 10³ particles/cm³ for the ammunition blasting and from 7.9 × 10³ to 1.3 × 10⁴ particles/cm³ for inert launches. Maximum peak concentrations, during emitting sources starting, were 75.5 × 10⁶ and 17.9 × 10⁶ particles/cm³, respectively. Particles from the drone launches were predominantly composed of silicon (Si), iron (Fe) and calcium (Ca), and those from the blasting campaigns by magnesium (Mg), sulphur (S), aluminum (Al), iron (Fe), barium (Ba) and silicon (Si); (4) Conclusions: The investigated sources produced UFPs with median values lower than other anthropogenic sources, and with a similar chemical composition.

  10. Modeling number of bacteria per food unit in comparison to bacterial concentration in quantitative risk assessment: impact on risk estimates.

    PubMed

    Pouillot, Régis; Chen, Yuhuan; Hoelzer, Karin

    2015-02-01

    When developing quantitative risk assessment models, a fundamental consideration for risk assessors is to decide whether to evaluate changes in bacterial levels in terms of concentrations or in terms of bacterial numbers. Although modeling bacteria in terms of integer numbers may be regarded as a more intuitive and rigorous choice, modeling bacterial concentrations is more popular as it is generally less mathematically complex. We tested three different modeling approaches in a simulation study. The first approach considered bacterial concentrations; the second considered the number of bacteria in contaminated units, and the third considered the expected number of bacteria in contaminated units. Simulation results indicate that modeling concentrations tends to overestimate risk compared to modeling the number of bacteria. A sensitivity analysis using a regression tree suggests that processes which include drastic scenarios consisting of combinations of large bacterial inactivation followed by large bacterial growth frequently lead to a >10-fold overestimation of the average risk when modeling concentrations as opposed to bacterial numbers. Alternatively, the approach of modeling the expected number of bacteria in positive units generates results similar to the second method and is easier to use, thus potentially representing a promising compromise. Published by Elsevier Ltd.

  11. Exposure assessment of a cyclist to PM10 and ultrafine particles.

    PubMed

    Berghmans, P; Bleux, N; Int Panis, L; Mishra, V K; Torfs, R; Van Poppel, M

    2009-02-01

    Estimating personal exposure to air pollution is a crucial component in identifying high-risk populations and situations. It will enable policy makers to determine efficient control strategies. Cycling is again becoming a favorite mode of transport both in developing and in developed countries due to increasing traffic congestion and environmental concerns. In Europe, it is also seen as a healthy sports activity. However, due to high levels of hazardous pollutants in the present day road microenvironment the cyclist might be at a higher health risk due to higher breathing rate and proximity to the vehicular exhaust. In this paper we present estimates of the exposure of a cyclist to particles of various size fractions including ultrafine particles (UFP) in the town of Mol (Flanders, Belgium). The results indicate relatively higher UFP concentration exposure during morning office hours and moderate UFP levels during afternoon. The major sources of UFP and PM(10) were identified, which are vehicular emission and construction activities, respectively. We also present a dust mapping technique which can be a useful tool for town planners and local policy makers.

  12. Air pollution ultrafine particles: toxicity beyond the lung.

    PubMed

    Terzano, C; Di Stefano, F; Conti, V; Graziani, E; Petroianni, A

    2010-10-01

    Ultrafine particles or nanoparticles (UFPs or PM0.1) are the fraction of ambient particulates with an aerodynamic diameter smaller than 0.1 microm. Currently UFPs are emerging as the most abundant particulate pollutants in urban and industrial areas, as their exposures have increased dramatically because of anthropogenic sources such as internal combustion engines, power plants, incinerators and many other sources of thermo-degradation. Ultrafine particles have been less studied than PM2.5 and PM10 particulates, mass concentrations of particles smaller than 2.5 and 10 microm, respectively. OBJECTIVE, EVIDENCE AND INFORMATION SOURCES: We examined the current scientific literature about the health effects of ultrafine particles exposure. UFPs are able to inhibit phagocytosis, and to stimulate inflammatory responses, damaging epithelial cells and potentially gaining access to the interstitium. They could be responsible for consistent reductions in forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in patients with asthma. Chronic exposure to UFPs can produce deleterious effects on the lung, also causing oxidative stress and enhancing pro-inflammatory effects in airways of COPD patients. Cardiovascular detrimental consequences due to UFPs exposure have observed in epidemiological studies, and could likely be explained by translocation of UFPs from the respiratory epithelium towards circulation and subsequent toxicity to vascular endothelium; alteration of blood coagulation; triggering of autonomic nervous system reflexes eventually altering the cardiac frequency and function. Once deposited deeply into the lung, UFPs--in contrast to larger-sized particles--appear to access to the blood circulation by different transfer routes and mechanisms, resulting in distribution throughout the body, including the brain, with potential neurotoxic consequences. UFPs represent an area of toxicology of emerging concern. A new concept of environmental medicine

  13. How comparable are size-resolved particle number concentrations from different instruments?

    NASA Astrophysics Data System (ADS)

    Hornsby, K. E.; Pryor, S. C.

    2012-12-01

    The need for comparability of particle size resolved measurements originates from multiple drivers including: (i) Recent suggestions that air quality standards for particulate matter should migrate from being mass-based to incorporating number concentrations. This move would necessarily be predicated on measurement comparability which is absolutely critical to compliance determination. (ii) The need to quantify and diagnose causes of variability in nucleation and growth rates in nano-particle experiments conducted in different locations. (iii) Epidemiological research designed to identify key parameters in human health responses to fine particle exposure. Here we present results from a detailed controlled laboratory instrument inter-comparison experiment designed to investigate data comparability in the size range of 2.01-523.3 nm across a range of particle composition, modal diameter and absolute concentration. Particle size distributions were generated using a TSI model 3940 Aerosol Generation System (AGS) diluted using zero air, and sampled using four TSI Scanning Mobility Particle Spectrometer (SMPS) configurations and a TSI model 3091 Fast Mobility Particle Sizer (FMPS). The SMPS configurations used two Electrostatic Classifiers (EC) (model 3080) attached to either a Long DMA (LDMA) (model 3081) or a Nano DMA (NDMA) (model 3085) plumbed to either a TSI model 3025A Butanol Condensed Particle Counting (CPC) or a TSI model 3788 Water CPC. All four systems were run using both high and low flow conditions, and were operated with both the internal diffusion loss and multiple charge corrections turned on. The particle compositions tested were sodium chloride, ammonium nitrate and olive oil diluted in ethanol. Particles of all three were generated at three peak concentration levels (spanning the range observed at our experimental site), and three modal particle diameters. Experimental conditions were maintained for a period of 20 minutes to ensure experimental

  14. Size-Fractionated Particle Number Concentrations and Daily Mortality in a Chinese City

    PubMed Central

    Meng, Xia; Ma, Yanjun; Chen, Renjie; Zhou, Zhijun; Chen, Bingheng

    2013-01-01

    Background: Associations between airborne particles and health outcomes have been documented worldwide; however, there is limited information regarding health effects associated with different particle sizes. Objectives: We explored the association between size-fractionated particle number concentrations (PNCs) and daily mortality in Shenyang, China. Methods: We collected daily data on cause-specific mortality and PNCs for particles measuring 0.25–10 μm in diameter between 1 December 2006 and 30 November 2008. We used quasi-Poisson regression generalized additive models to estimate associations between PNCs and mortality, and we used natural spline smoothing functions to adjust for time-varying covariates and long-term and seasonal trends. Results: Mean numbers of daily deaths were 67, 32, and 7 for all natural causes, cardiovascular diseases, and respiratory diseases, respectively. Interquartile range (IQR) increases in PNCs for particles measuring 0.25–0.50 μm were significantly associated with total and cardiovascular mortality, but not respiratory mortality. Effect estimates were larger for PNCs during the warm season than the cool season, and increased with decreasing particle size. IQR increases in PNCs of 0.25–0.28 μm, 0.35–0.40 μm, and 0.45–0.50 μm particles were associated with 2.41% (95% CI: 1.23, 3.58%), 1.31% (95% CI: 0.52, 2.09%), and 0.45% (95% CI: 0.04, 0.87%) higher total mortality, respectively. Associations were generally stable after adjustment for mass concentrations of ambient particles and gaseous pollutants. Conclusions: Our findings suggest that particles < 0.5 μm in diameter may be most responsible for adverse health effects of particulate air pollution and that adverse health effects may increase with decreasing particle size. Citation: Meng X, Ma Y, Chen R, Zhou Z, Chen B, Kan H. 2013. Size-fractionated particle number concentrations and daily mortality in a Chinese city. Environ Health Perspect 121:1174–1178;

  15. Explaining the spatiotemporal variation of fine particle number concentrations over Beijing and surrounding areas in an air quality model with aerosol microphysics.

    PubMed

    Chen, Xueshun; Wang, Zifa; Li, Jie; Chen, Huansheng; Hu, Min; Yang, Wenyi; Wang, Zhe; Ge, Baozhu; Wang, Dawei

    2017-12-01

    In this study, a three-dimensional air quality model with detailed aerosol microphysics (NAQPMS + APM) was applied to simulate the fine particle number size distribution and to explain the spatiotemporal variation of fine particle number concentrations in different size ranges over Beijing and surrounding areas in the haze season (Jan 15 to Feb 13 in 2006). Comparison between observations and the simulation indicates that the model is able to reproduce the main features of the particle number size distribution. The high number concentration of total particles, up to 26600 cm -3 in observations and 39800 cm -3 in the simulation, indicates the severity of pollution in Beijing. We find that primary particles with secondary species coating and secondary particles together control the particle number size distribution. Secondary particles dominate particle number concentration in the nucleation mode. Primary and secondary particles together determine the temporal evolution and spatial pattern of particle number concentration in the Aitken mode. Primary particles dominate particle number concentration in the accumulation mode. Over Beijing and surrounding areas, secondary particles contribute at least 80% of particle number concentration in the nucleation mode but only 10-20% in the accumulation mode. Nucleation mode particles and accumulation mode particles are anti-phased with each other. Nucleation or primary emissions alone could not explain the formation of the particle number size distribution in Beijing. Nucleation has larger effects on ultrafine particles while primary particles emissions are efficient in producing large particles in the accumulation mode. Reduction in primary particle emissions does not always lead to a decrease in the number concentration of ultrafine particles. Measures to reduce fine particle pollution in terms of particle number concentration may be different from those addressing particle mass concentration. Copyright © 2017 Elsevier

  16. Impact of meteorology, traffic characteristics, and distance from roadway on roadside concentrations of ultrafine particulate matter

    EPA Science Inventory

    Traffic-laden roadways are major contributors to poor air quality in developed areas, elevating pollutants such as particulate matter (PM) and ozone. Among the numerous air pollutants emitted by vehicles, ultrafine particles (UFPs, diameter <100 nm) are of interest as a potentia...

  17. Group size and visitor numbers predict faecal glucocorticoid concentrations in zoo meerkats

    PubMed Central

    Scott, Katy; Heistermann, Michael

    2017-01-01

    Measures of physiological stress in zoo animals can give important insights into how they are affected by aspects of their captive environment. We analysed the factors influencing variation in glucocorticoid metabolites in faeces (fGCs) from zoo meerkats as a proxy for blood cortisol concentration, high levels of which are associated with a stress response. Levels of fGCs in captive meerkats declined with increasing group size. In the wild, very small groups of meerkats are at a higher risk of predation, while in larger groups, there is increased competition for resources. Indeed, group sizes in captivity resemble those seen in unstable coalitions in the wild, which may represent a stressful condition and predispose meerkats to chronic stress, even in the absence of natural predators. Individuals in large enclosures showed lower levels of stress, but meerkat density had no effect on the stress measures. In contrast with data from wild meerkats, neither sex, age nor dominance status predicted stress levels, which may reflect less food stress owing to more equal access to resources in captivity versus wild. The median number of visitors at the enclosure was positively correlated with fGC concentrations on the following day, with variation in the visitor numbers having the opposite effect. Our results are consistent with the hypothesis that there is an optimum group size which minimizes physiological stress in meerkats, and that zoo meerkats at most risk of physiological stress are those kept in small groups and small enclosures and are exposed to consistently high numbers of visitors. PMID:28484620

  18. Group size and visitor numbers predict faecal glucocorticoid concentrations in zoo meerkats.

    PubMed

    Scott, Katy; Heistermann, Michael; Cant, Michael A; Vitikainen, Emma I K

    2017-04-01

    Measures of physiological stress in zoo animals can give important insights into how they are affected by aspects of their captive environment. We analysed the factors influencing variation in glucocorticoid metabolites in faeces (fGCs) from zoo meerkats as a proxy for blood cortisol concentration, high levels of which are associated with a stress response. Levels of fGCs in captive meerkats declined with increasing group size. In the wild, very small groups of meerkats are at a higher risk of predation, while in larger groups, there is increased competition for resources. Indeed, group sizes in captivity resemble those seen in unstable coalitions in the wild, which may represent a stressful condition and predispose meerkats to chronic stress, even in the absence of natural predators. Individuals in large enclosures showed lower levels of stress, but meerkat density had no effect on the stress measures. In contrast with data from wild meerkats, neither sex, age nor dominance status predicted stress levels, which may reflect less food stress owing to more equal access to resources in captivity versus wild. The median number of visitors at the enclosure was positively correlated with fGC concentrations on the following day, with variation in the visitor numbers having the opposite effect. Our results are consistent with the hypothesis that there is an optimum group size which minimizes physiological stress in meerkats, and that zoo meerkats at most risk of physiological stress are those kept in small groups and small enclosures and are exposed to consistently high numbers of visitors.

  19. Characterizing local traffic contributions to particulate air pollution in street canyons using mobile monitoring techniques

    NASA Astrophysics Data System (ADS)

    Zwack, Leonard M.; Paciorek, Christopher J.; Spengler, John D.; Levy, Jonathan I.

    2011-05-01

    Traffic within urban street canyons can contribute significantly to ambient concentrations of particulate air pollution. In these settings, it is challenging to separate within-canyon source contributions from urban and regional background concentrations given the highly variable and complex emissions and dispersion characteristics. In this study, we used continuous mobile monitoring of traffic-related particulate air pollutants to assess the contribution to concentrations, above background, of traffic in the street canyons of midtown Manhattan. Concentrations of both ultrafine particles (UFP) and fine particles (PM 2.5) were measured at street level using portable instruments. Statistical modeling techniques accounting for autocorrelation were used to investigate the presence of spatial heterogeneity of pollutant concentrations as well as to quantify the contribution of within-canyon traffic sources. Measurements were also made within Central Park, to examine the impact of offsets from major roadways in this urban environment. On average, an approximate 11% increase in concentrations of UFP and 8% increase in concentrations of PM 2.5 over urban background was estimated during high-traffic periods in street canyons as opposed to low traffic periods. Estimates were 8% and 5%, respectively, after accounting for temporal autocorrelation. Within Central Park, concentrations were 40% higher than background (5% after accounting for temporal autocorrelation) within the first 100 m from the nearest roadway for UFP, with a smaller but statistically significant increase for PM 2.5. Our findings demonstrate the viability of a mobile monitoring protocol coupled with spatiotemporal modeling techniques in characterizing local source contributions in a setting with street canyons.

  20. Where to locate transit stops: Cross-intersection profiles of ultrafine particles and implications for pedestrian exposure.

    PubMed

    Choi, Wonsik; Ranasinghe, Dilhara; DeShazo, J R; Kim, Jae-Jin; Paulson, Suzanne E

    2018-02-01

    Epidemiological studies have shown that exposure to traffic-related pollutants increases incidence of adverse health outcomes. Transit users in cities across the globe commonly spend 15-45 min or more waiting at transit stops each day, often at locations with high levels of pollution from traffic. Here, we investigate the characteristics of concentration profiles of ultrafine particles (UFP) with 5 m spatial resolution across intersections, to determine the best place to site transit stops to minimize exposures. Cross-intersection UFP profiles were derived from 1744 profiles covering 90 m before and after each intersection center with a mobile monitoring platform. Measurements were made at 10 signalized intersections located at six urban sites, each with a distinct built environment, during both mornings and afternoons. Measurements were made within 1.5 m of the sidewalk and approximately at breathing height (1.5 m above ground level) to approximate sidewalk exposures. UFP profiles were strongly influenced by high emissions from vehicle stops and accelerations, and peaked within 30 m of intersection centers; from there concentrations decreased sharply with distance. Peak concentrations averaged about 90% higher than the minima along the block. They were accompanied by more frequent and larger transient concentration spikes, increasing the chance of people near the intersection being exposed to both short-term extremely high concentration spikes and higher average concentrations. The decays are somewhat larger before the intersection than after the intersection, however as siting transit stops after intersections is preferred for smooth traffic flow, we focus on after the intersection. Simple time-duration exposure calculations combined with breathing rates suggest moving a bus stop from 20 to 40-50 m after the intersection can reduce transit-users' exposure levels to total UFP substantially, in proportion to the reciprocal of the magnitude of elevation at

  1. Impacts of Future European Emission Reductions on Aerosol Particle Number Concentrations Accounting for Effects of Ammonia, Amines, and Organic Species.

    PubMed

    Julin, Jan; Murphy, Benjamin N; Patoulias, David; Fountoukis, Christos; Olenius, Tinja; Pandis, Spyros N; Riipinen, Ilona

    2018-01-16

    Although they are currently unregulated, atmospheric ultrafine particles (<100 nm) pose health risks because of, e.g., their capability to penetrate deep into the respiratory system. Ultrafine particles, often minor contributors to atmospheric particulate mass, typically dominate aerosol particle number concentrations. We simulated the response of particle number concentrations over Europe to recent estimates of future emission reductions of aerosol particles and their precursors. We used the chemical transport model PMCAMx-UF, with novel updates including state-of-the-art descriptions of ammonia and dimethylamine new particle formation (NPF) pathways and the condensation of organic compounds onto particles. These processes had notable impacts on atmospheric particle number concentrations. All three emission scenarios (current legislation, optimized emissions, and maximum technically feasible reductions) resulted in substantial (10-50%) decreases in median particle number concentrations over Europe. Consistent reductions were predicted in Central Europe, while Northern Europe exhibited smaller reductions or even increased concentrations. Motivated by the improved NPF descriptions for ammonia and methylamines, we placed special focus on the potential to improve air quality by reducing agricultural emissions, which are a major source of these species. Agricultural emission controls showed promise in reducing ultrafine particle number concentrations, although the change is nonlinear with particle size.

  2. The effect of image force and diffusion on the deposition of ultrafine particle to vegetation

    NASA Astrophysics Data System (ADS)

    Lin, M. Y.; Katul, G. G.; Huang, C. W.; CHU, C. R.; Khlystov, A.

    2017-12-01

    Ultrafine particles (UFP) along with their sources and sinks are gaining significant attention due to their dual role in cloud microphysics and human health. Due to its expansive areal extent, vegetation is a significant sink for UFP thus prompting interest in how UFP deposit onto vegetated surfaces. Single fiber theory reasonably explains deposition of zero charge UFP onto vegetation by treating vegetation as filter media. However, the ability of the single fiber theory to predict deposition of charged UFP onto vegetation remains unknown and frames the scope of this presentation. Wind tunnel experiments are used to investigate UFP deposition (size range 12.6 - 102 nm) onto Juniper branches (Juniperus chinesis) and their results are interpreted using single fiber theory. Three different wind speeds (0.3, 0.6, and 0.9 m/s) are investigated to study deposition of singly-charged particles and these deposition values are contrasted with neutrally charged particles. The wind tunnel experiments indicate that single fiber theory can be used to describe deposition of singly-charged particles onto vegetation if both the image force and Brownian diffusion are simultaneously considered. The image force was found to be proportional to KIM0.5 when the image force dimensionless number (KIM) is smaller than 10-8, a common condition for singly charged UFP particle. The proportionality constant was found to be 27.6 (i.e. 27.6×KIM0.5) and is larger than a previously reported value (9.7) derived for KIM between 10-7 10-5, primarily due to the lower KIM (<10-8) in this study. Another study also showed that this proportionality constant increases with decreasing KIM. With this representation for the image force, the single fiber filtration model and measurements agree to within 20%. The work here offers a new perspective on the role of image force at small KIM (10-10 10-8) and its role in enhanced deposition of charged UFP onto vegetation.

  3. Ambient and Controlled Particle Exposures as Triggers for Acute ECG Changes.

    PubMed

    Rich, David Q; Peters, Annette; Schneider, Alexandra; Zareba, Wojciech; Breitner, Susanne; Oakes, David; Wiltshire, Jelani; Kane, Cathleen; Frampton, Mark W; Hampel, Regina; Hopke, Philip K; Cyrys, Josef; Utell, Mark J

    2016-05-01

    antioxidant capacity measured in stored blood samples. Ambient con- centrations of UFPs, accumulation-mode particles (AMP, particles with an aerodynamic diameter of 100-500 nm), fine PM (PM2.5, particles with an aerodynamic diameter 2.5 pm), and black carbon (BC) were also available. We first conducted factor analyses in each study to find subgroups of correlated ECG outcomes and to reduce the number of outcomes examined in our statistical models. We then restricted the statistical analyses to the factors and representative.outcomes that were common to all four studies, including total HRV (measured as the standard deviation of normal-to-normal [NN] beat intervals [SDNNj), parasympathetic modulation (measured as the root mean square of the successive differences [RMSSD between adjacent NN beat intervals), and T-wave morphol- ogy (measured as T-wave complexity). Next, we used addi- tive mixed models to estimate the change in each outcome associated with increased pollutant concentrations in the . concurrent and previous 6 hours and with 5-minute inter- vals up to the previous 60 minutes, accounting for the correlation of repeated outcome measures for each subject and adjusting for time trend, hour of the day, temperature, relative humidity, day of the week, month, and visit number. Because multiple comparisons were an issue in our. analyses, we used a discovery-and-replication approach to draw conclusions across studies for each research question. In the Augsburg study, interquartile range (IQR) increases in UFP concentrations lagged 2 to 5 hours were associated with 1%-3% decreases in SDNN (e.g., lagged 3 hours in the group with a genetic susceptibility: -2.26%; 95% confidence interval [CI], -3.98% to -0.53%). In the REHAB study, similarly, IQR increases in UFP concentra- tions in the previous 5 hours were associated with < 3% decreases in SDNN (e.g., lagged 1 hour: -2.69%; 95% CI, -5.13% to -0.26%). We also found decreases in SDNN associated with IQR increases in total

  4. Particulate Matter Mass and Number Concentrations Inside a Naturally Ventilated School Building Located Adjacent to an Urban Roadway

    NASA Astrophysics Data System (ADS)

    Chithra, V. S.; Shiva Nagendra, S. M.

    2014-09-01

    This work presents the temporal characteristics of Particulate Matter (PM) mass and number concentrations measured inside a naturally ventilated school building, located close to a busy roadway in Chennai city. Two environmental dust monitor instruments (GRIMM Model 107 and Model 108) were used for measuring PM mass and number concentrations. The 1-h mean values of PM10, PM2.5 and PM1 mass concentrations were found to be 262 ± 161, 68 ± 24, 40 ± 15 µg/m3 and 81 ± 26, 56 ± 2, 45 ± 19 µg/m3 during working hours (8am-4pm) and non-working hours (4pm-8am)/holidays, respectively. The PM number concentrations inside the room during working hours were found to be 2.4 × 105, 2.2 × 103 and 8.1 × 102 particles/l in the size range of 0.3-1, 1-3 and 3-10 µm, respectively. The present study reveals that during working hours, indoor PM concentrations of the classroom were influenced by the activities of occupants and during non working hours it was affected by outdoor vehicular emissions.

  5. Numerical simulation on the effects of drug eluting stents at different Reynolds numbers on hemodynamic and drug concentration distribution.

    PubMed

    Chen, Yu; Xiong, Yan; Jiang, Wentao; Yan, Fei; Guo, Meng; Wang, Qingyuan; Fan, Yubo

    2015-01-01

    The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis. A 3D virtual stent with 90° curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800. The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend. It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.

  6. Characterizing the spatial distribution of ambient ultrafine particles in Toronto, Canada: A land use regression model.

    PubMed

    Weichenthal, Scott; Van Ryswyk, Keith; Goldstein, Alon; Shekarrizfard, Maryam; Hatzopoulou, Marianne

    2016-01-01

    Exposure models are needed to evaluate the chronic health effects of ambient ultrafine particles (<0.1 μm) (UFPs). We developed a land use regression model for ambient UFPs in Toronto, Canada using mobile monitoring data collected during summer/winter 2010-2011. In total, 405 road segments were included in the analysis. The final model explained 67% of the spatial variation in mean UFPs and included terms for the logarithm of distances to highways, major roads, the central business district, Pearson airport, and bus routes as well as variables for the number of on-street trees, parks, open space, and the length of bus routes within a 100 m buffer. There was no systematic difference between measured and predicted values when the model was evaluated in an external dataset, although the R(2) value decreased (R(2) = 50%). This model will be used to evaluate the chronic health effects of UFPs using population-based cohorts in the Toronto area. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. Association of ultrafine particles with cardiopulmonary health among adult subjects in the urban areas of northern Taiwan.

    PubMed

    Liu, Jun-Yu; Hsiao, Ta-Chih; Lee, Kang-Yun; Chuang, Hsiao-Chi; Cheng, Tsun-Jen; Chuang, Kai-Jen

    2018-06-15

    The association between short-term exposure to particulate air pollution, especially fine particles, and cardiopulmonary health has been well-established in previous studies. However, previous findings regarding the effect of ultrafine particles (UFPs) on cardiopulmonary health are inconsistent. We repeatedly measured the mass concentrations of UFPs using a Micro-Orifice Uniform Deposit Impactor (MOUDI) in the apartments of 100 adult participants and collected the participants' health data from the pulmonary outpatient unit of Shuang-Ho Hospital to investigate the association between short-term exposure to UFPs and cardiopulmonary health using mixed-effects models from January 1, 2014 to August 31, 2017. We also collected ambient air pollution monitoring data from the Taiwan Environmental Protection Administration for data analysis. We observed that an interquartile range increase in the 24-hour mean UFPs (0.97 μg/m 3 ) was associated with a 6.3% [95% confidence interval (CI) = 2.9, 9.7], 5.6% (95% CI = 4.1, 7.1) and 8.5% (95% CI = 3.9, 13.1) increase in systolic blood pressure, diastolic blood pressure and high sensitivity-C-reactive protein, respectively. We also observed the association of particulate matter less than or equal to 2.5 μm in diameter and nitrogen dioxide with increased blood pressure and ozone with decreased lung function. A negative trend between UFPs and forced expiratory volume in the first second was observed. We concluded that short-term exposure to UFPs was associated with cardiovascular health in adult subjects in the urban areas of northern Taiwan. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Nutritive value of methane fermentation residue in diets fed to feedlot steers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, J.M.; Shirley, R.L.; Palmer, A.Z.

    1982-12-01

    Nutritive value of the methane fermentation residue (MFR) from the effluent of a large scale thermophilic methane generator was determined in diets fed to feedlot steers. The MFR contained 22.2% dry matter and 21.9% crude protein (dry basis). Two diets containing 10.6% (dry basis) MFR were formulated using the Urea Fermentation Potential (UFP) system such that in one diet N was in excess (-1.6 UFP) while in the other diet energy was in excess (+2.6 UFP). These two diets were compared in a California Net Energy trial with a feedlot diet (-.3 UFP) containing the same ingredients except the MFR.more » Six steers were fed in a replicated 3(2) Latin square metabolism trial and 70 steers were fed in a 118-d comparative-slaughter, feedlot trial. Digestibilities of dry matter, organic matter, crude protein, acid detergent fiber, ash, total digestible nutrients (TDN) and metabolizable energy were depressed (all P less than .05) in the MFR-containing diets. Steers fed the MFR-containing diets had lower (P less than .05) rates of gain and increased (P less than .05) feed requirements per unit gain. Net energies for maintenance and gain were slightly lower for the MFR-containing diets than the control diet. Crude protein digestibility for the MFR calculated by difference, for the -UFP and the +UFP diets were 37.8 and 50.7%, while corresponding values for TDN were 28.8 and 12.8%, respectively. Concentrations of potentially toxic elements in kidney, liver and muscle as well as flavor and tenderness of steaks were not affected by feeding MFR.« less

  9. Number concentration and size distribution of aerosol particles in the middle troposphere over the Western Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Zaizen, Yuji; Ikegami, Miwako; Tsutsumi, Yukitomo; Makino, Yukio; Okada, Kikuo; Jensen, Jørgen; Gras, John L.

    Number concentration and size distribution of aerosol particles were measured on board aircraft during the PACE (Pacific Atmospheric Chemistry Experiment) campaign from Australia to Japan in January 1994. The spatial distribution of condensation nuclei (CN) ( r ⩾ 4 nm) at 5-6 km altitude showed large variabilities in concentrations from 10 2 to 10 3 mg -1 that is, the concentrations were low (70-500 mg -1) in the intertropical convergence zone, high (400-1500 mg -1) in the subtropical highpressure area, and low again in the higher latitudes. An apparent opposite tendency was present between CN and large particle ( r ⩾ 0.15 μm) concentrations. The size distributions in the subtropical region exhibited high number concentrations of very fine particles ( r < 0.02 μm). Together with the horizontal observation, vertical observations of aerosols were carried out over some areas. In the subtropical area (Saipan), CN concentration increased with altitude in contrast to the large particle concentration. Also most of the particles collected at 6 km altitude over Saipan contained sulfuric acid. These results are consistent with the results of Clarke (1993, J. geophys. Res.98, 20,633-20,647) that new particle formation is favored in the upper troposphere.

  10. Local lung deposition of ultrafine particles in healthy adults: experimental results and theoretical predictions.

    PubMed

    Sturm, Robert

    2016-11-01

    Ultrafine particles (UFP) of biogenic and anthropogenic origin occur in high numbers in the ambient atmosphere. In addition, aerosols containing ultrafine powders are used for the inhalation therapy of various diseases. All these facts make it necessary to obtain comprehensive knowledge regarding the exact behavior of UFP in the respiratory tract. Theoretical simulations of local UFP deposition are based on previously conducted inhalation experiments, where particles with various sizes (0.04, 0.06, 0.08, and 0.10 µm) were administered to the respiratory tract by application of the aerosol bolus technique. By the sequential change of the lung penetration depth of the inspired bolus, different volumetric lung regions could be generated and particle deposition in these regions could be evaluated. The model presented in this contribution adopted all parameters used in the experiments. Besides the obligatory comparison between practical and theoretical data, also advanced modeling predictions including the effect of varying functional residual capacity (FRC) and respiratory flow rate were conducted. Validation of the UFP deposition model shows that highest deposition fractions occur in those volumetric lung regions corresponding to the small and partly alveolated airways of the tracheobronchial tree. Particle deposition proximal to the trachea is increased in female probands with respect to male subjects. Decrease of both the FRC and the respiratory flow rate results in an enhancement of UFP deposition. The study comes to the conclusion that deposition of UFP taken up via bolus inhalation is influenced by a multitude of factors, among which lung morphometry and breathing conditions play a superior role.

  11. Local lung deposition of ultrafine particles in healthy adults: experimental results and theoretical predictions

    PubMed Central

    2016-01-01

    Background Ultrafine particles (UFP) of biogenic and anthropogenic origin occur in high numbers in the ambient atmosphere. In addition, aerosols containing ultrafine powders are used for the inhalation therapy of various diseases. All these facts make it necessary to obtain comprehensive knowledge regarding the exact behavior of UFP in the respiratory tract. Methods Theoretical simulations of local UFP deposition are based on previously conducted inhalation experiments, where particles with various sizes (0.04, 0.06, 0.08, and 0.10 µm) were administered to the respiratory tract by application of the aerosol bolus technique. By the sequential change of the lung penetration depth of the inspired bolus, different volumetric lung regions could be generated and particle deposition in these regions could be evaluated. The model presented in this contribution adopted all parameters used in the experiments. Besides the obligatory comparison between practical and theoretical data, also advanced modeling predictions including the effect of varying functional residual capacity (FRC) and respiratory flow rate were conducted. Results Validation of the UFP deposition model shows that highest deposition fractions occur in those volumetric lung regions corresponding to the small and partly alveolated airways of the tracheobronchial tree. Particle deposition proximal to the trachea is increased in female probands with respect to male subjects. Decrease of both the FRC and the respiratory flow rate results in an enhancement of UFP deposition. Conclusions The study comes to the conclusion that deposition of UFP taken up via bolus inhalation is influenced by a multitude of factors, among which lung morphometry and breathing conditions play a superior role. PMID:27942511

  12. Observations of urban airborne particle number concentrations during rush-hour conditions: analysis of the number based size distributions and modal parameters.

    PubMed

    Lingard, Justin J N; Agus, Emily L; Young, David T; Andrews, Gordon E; Tomlin, Alison S

    2006-12-01

    A summertime study of the number concentration and the size distribution of combustion derived nanometre sized particles (termed nanoparticles) from diesel and spark-ignition (SI) engine emissions were made under rush-hour and free-flow traffic conditions at an urban roadside location in Leeds, UK in July 2003. The measured total particle number concentrations (N(TOTAL)) were of the order 1.8 x 10(4) to 3.4 x 10(4) cm(-3), and tended to follow the diurnal traffic flow patterns. The N(TOTAL) was dominated by particles < or =100 nm in diameter which accounted for between 89-93% of the measured particle number. By use of a log-normal fitting procedure, the modal parameters of the number based particle size distribution of urban airborne particulates were derived from the roadside measurements. Four component modes were identified. Two nucleation modes were found, with a smaller, more minor, mode composed principally of sub-11 nm particles, believed to be derived from particles formed from the nucleation of gaseous species in the atmosphere. A second mode, much larger in terms of number, was composed of particles within the size range of 10-20 nm. This second mode was believed to be principally derived from the condensation of the unburned fuel and lube oil (the solvent organic fraction or SOF) as it cooled on leaving the engine exhaust. Third and fourth modes were noted within the size ranges of 28-65 nm and 100-160 nm, respectively. The third mode was believed to be representative of internally mixed Aitken mode particles composed of a soot/ash core with an adsorbed layer of readily volatilisable material. The fourth mode was believed to be composed of chemically aged, secondary particles. The larger nucleation and Aitken modes accounted for between 80-90% of the measured N(TOTAL), and the particles in these modes were believed to be derived from SI and diesel engine emissions. The overall size distribution, particularly in modes II-IV, was observed to be strongly

  13. Automated Analysis of Human Sperm Number and Concentration (Oligospermia) Using Otsu Threshold Method and Labelling

    NASA Astrophysics Data System (ADS)

    Susrama, I. G.; Purnama, K. E.; Purnomo, M. H.

    2016-01-01

    Oligospermia is a male fertility issue defined as a low sperm concentration in the ejaculate. Normally the sperm concentration is 20-120 million/ml, while Oligospermia patients has sperm concentration less than 20 million/ml. Sperm test done in the fertility laboratory to determine oligospermia by checking fresh sperm according to WHO standards in 2010 [9]. The sperm seen in a microscope using a Neubauer improved counting chamber and manually count the number of sperm. In order to be counted automatically, this research made an automation system to analyse and count the sperm concentration called Automated Analysis of Sperm Concentration Counters (A2SC2) using Otsu threshold segmentation process and morphology. Data sperm used is the fresh sperm directly in the analysis in the laboratory from 10 people. The test results using A2SC2 method obtained an accuracy of 91%. Thus in this study, A2SC2 can be used to calculate the amount and concentration of sperm automatically

  14. Source apportionment of PM2.5 chemically speciated mass and particle number concentrations in New York City

    NASA Astrophysics Data System (ADS)

    Masiol, M.; Hopke, P. K.; Felton, H. D.; Frank, B. P.; Rattigan, O. V.; Wurth, M. J.; LaDuke, G. H.

    2017-01-01

    The major sources of fine particulate matter (PM2.5) in New York City (NYC) were apportioned by applying positive matrix factorization (PMF) to two different sets of particle characteristics: mass concentrations using chemical speciation data and particle number concentrations (PNC) using number size distribution, continuously monitored gases, and PM2.5 data. Post-processing was applied to the PMF results to: (i) match with meteorological data, (ii) use wind data to detect the likely locations of the local sources, and (iii) use concentration weighted trajectory models to assess the strength of potential regional/transboundary sources. Nine sources of PM2.5 mass were apportioned and identified as: secondary ammonium sulfate, secondary ammonium nitrate, road traffic exhaust, crustal dust, fresh sea-salt, aged sea-salt, biomass burning, residual oil/domestic heating and zinc. The sources of PNC were investigated using hourly average number concentrations in six size bins, gaseous air pollutants, mass concentrations of PM2.5, particulate sulfate, OC, and EC. These data were divided into 3 periods indicative of different seasonal conditions. Five sources were resolved for each period: secondary particles, road traffic, NYC background pollution (traffic and oil heating largely in Manhattan), nucleation and O3-rich aerosol. Although traffic does not account for large amounts of PM2.5 mass, it was the main source of particles advected from heavily trafficked zones. The use of residual oil had limited impacts on PM2.5 mass but dominates PNC in cold periods.

  15. Development of land-use regression models for exposure assessment to ultrafine particles in Rome, Italy

    NASA Astrophysics Data System (ADS)

    Cattani, Giorgio; Gaeta, Alessandra; di Menno di Bucchianico, Alessandro; de Santis, Antonella; Gaddi, Raffaela; Cusano, Mariacarmela; Ancona, Carla; Badaloni, Chiara; Forastiere, Francesco; Gariazzo, Claudio; Sozzi, Roberto; Inglessis, Marco; Silibello, Camillo; Salvatori, Elisabetta; Manes, Fausto; Cesaroni, Giulia; The Viias Study Group

    2017-05-01

    The health effects of long-term exposure to ultrafine particles (UFPs) are poorly understood. Data on spatial contrasts in ambient ultrafine particles (UFPs) concentrations are needed with fine resolution. This study aimed to assess the spatial variability of total particle number concentrations (PNC, a proxy for UFPs) in the city of Rome, Italy, using land use regression (LUR) models, and the correspondent exposure of population here living. PNC were measured using condensation particle counters at the building facade of 28 homes throughout the city. Three 7-day monitoring periods were carried out during cold, warm and intermediate seasons. Geographic Information System predictor variables, with buffers of varying size, were evaluated to model spatial variations of PNC. A stepwise forward selection procedure was used to develop a "base" linear regression model according to the European Study of Cohorts for Air Pollution Effects project methodology. Other variables were then included in more enhanced models and their capability of improving model performance was evaluated. Four LUR models were developed. Local variation in UFPs in the study area can be largely explained by the ratio of traffic intensity and distance to the nearest major road. The best model (adjusted R2 = 0.71; root mean square error = ±1,572 particles/cm³, leave one out cross validated R2 = 0.68) was achieved by regressing building and street configuration variables against residual from the "base" model, which added 3% more to the total variance explained. Urban green and population density in a 5,000 m buffer around each home were also relevant predictors. The spatial contrast in ambient PNC across the large conurbation of Rome, was successfully assessed. The average exposure of subjects living in the study area was 16,006 particles/cm³ (SD 2165 particles/cm³, range: 11,075-28,632 particles/cm³). A total of 203,886 subjects (16%) lives in Rome within 50 m from a high traffic road and they

  16. Traffic pollutant exposures experienced by pedestrians waiting to enter the U.S. at a major U.S.-Mexico border crossing

    NASA Astrophysics Data System (ADS)

    Galaviz, V. E.; Yost, M. G.; Simpson, C. D.; Camp, J. E.; Paulsen, M. H.; Elder, J. P.; Hoffman, L.; Flores, D.; Quintana, P. J. E.

    2014-05-01

    Pedestrians waiting to cross into the US from Mexico at Ports of Entry experience long wait times near idling vehicles. The near-road environment is associated with elevated pollutant levels and adverse health outcomes. This is the first exposure assessment conducted to quantify northbound pedestrian commuter exposure to traffic-related air pollutants at the U.S.-Mexico border San Ysidro Port of Entry (SYPOE). Seventy-three persons who regularly crossed the SYPOE in the pedestrian line and 18 persons who did not cross were recruited to wear personal air monitors for 24-h to measure traffic pollutants particulate matter less than 2.5 μm (PM2.5), 1-nitropyrene (1-NP) - a marker for diesel exhaust - and carbon monoxide (CO). Fixed site concentrations were collected at SYPOE and occurred during the time subjects were crossing northbound to approximate their exposure to 1-NP, ultrafine particles (UFP), PM2.5, CO, and black carbon (BC) while standing in line during their border wait. Subjects who crossed the border in pedestrian lanes had a 6-fold increase in exposure to 1-NP, a 3-fold increase in exposure to CO, and a 2-fold increase in exposure to gravimetric PM2.5, vs. non-border commuters. Univariate regression analysis for UFP (median 40,000 # cm-3) found that border wait time for vehicles explained 21% of variability and relative humidity 13%, but when modeled together neither predictor remained significant. Concentrations at the SYPOE of UFP, PM2.5, CO, and BC are similar to those in other near-roadway studies that show associations with acute and chronic adverse health effects. Although results are limited by small sample numbers, these findings warrant concern for adverse health effects experienced by pedestrian commuters waiting in a long northbound queue at SYPOE and demonstrates a potential health benefit of reduced wait times at the border.

  17. A study on the relationship between mass concentrations, chemistry and number size distribution of urban fine aerosols in Milan, Barcelona and London

    NASA Astrophysics Data System (ADS)

    Rodríguez, S.; van Dingenen, R.; Putaud, J.-P.; Dell'Acqua, A.; Pey, J.; Querol, X.; Alastuey, A.; Chenery, S.; Ho, K.-F.; Harrison, R.; Tardivo, R.; Scarnato, B.; Gemelli, V.

    2007-05-01

    A physicochemical characterization, including aerosol number size distribution, chemical composition and mass concentrations, of the urban fine aerosol captured in MILAN, BARCELONA and LONDON is presented in this article. The objective is to obtain a comprehensive picture of the microphysical processes involved in aerosol dynamics during the: 1) regular evolution of the urban aerosol (daily, weekly and seasonal basis) and in the day-to-day variations (from clean-air to pollution-events), and 2) the link between "aerosol chemistry and mass concentrations" with the "number size distribution". The mass concentrations of the fine PM2.5 aerosol exhibit a high correlation with the number concentration of >100 nm particles N>100 (nm) ("accumulation mode particles") which only account for <20% of the total number concentration N of fine aerosols; but do not correlate with the number of <100 nm particles ("ultrafine particles"), which accounts for >80% of fine particles number concentration. Organic matter and black-carbon are the only aerosol components showing a significant correlation with the ultrafine particles, attributed to vehicles exhausts emissions; whereas ammonium-nitrate, ammonium-sulphate and also organic matter and black-carbon correlate with N>100 (nm) and attributed to condensation mechanisms, other particle growth processes and some primary emissions. Time series of the aerosol DpN diameter (dN/dlogD mode), mass PM2.5 concentrations and number N>100 (nm) concentrations exhibit correlated day-to-day variations, which point to a significant involvement of condensation of semi-volatile compounds during urban pollution events. This agrees with the observation that ammonium-nitrate is the component exhibiting the highest increases from mid-to-high pollution episodes, when the highest DpN increases are observed. The results indicates that "fine PM2.5 particles urban pollution events" tend to occur when condensation processes have made particles grow large enough

  18. Atmospheric ultrafine particles promote vascular calcification via the NF-κB signaling pathway

    PubMed Central

    Li, Rongsong; Mittelstein, David; Kam, Winnie; Pakbin, Payam; Du, Yunfeng; Tintut, Yin; Navab, Mohamad; Sioutas, Constantinos

    2013-01-01

    Exposure to atmospheric fine particulate matter (PM2.5) is a modifiable risk factor of cardiovascular disease. Ultrafine particles (UFP, diameter <0.1 μm), a subfraction of PM2.5, promote vascular oxidative stress and inflammatory responses. Epidemiologic studies suggest that PM exposure promotes vascular calcification. Here, we assessed whether UFP exposure promotes vascular calcification via NF-κB signaling. UFP exposure at 50 μg/ml increased alkaline phosphatase (ALP) activity by 4.4 ± 0.2-fold on day 3 (n = 3, P < 0.001) and matrix calcification by 3.5 ± 1.7-fold on day 10 (n = 4, P < 0.05) in calcifying vascular cells (CVC), a subpopulation of vascular smooth muscle cells with osteoblastic potential. Treatment of CVC with conditioned media derived from UFP-treated macrophages (UFP-CM) also led to an increase in ALP activities and matrix calcification. Furthermore, both UFP and UFP-CM significantly increased NF-κB activity, and cotreatment with an NF-κB inhibitor, JSH23, attenuated both UFP- and UFP-CM-induced ALP activity and calcification. When low-density lipoprotein receptor-null mice were exposed to UFP at 359.5 μg/m3 for 10 wk, NF-κB activation and vascular calcification were detected in the regions of aortic roots compared with control filtered air-exposed mice. These findings suggest that UFP promotes vascular calcification via activating NF-κB signaling. PMID:23242187

  19. Determinants of black carbon, particle mass and number concentrations in London transport microenvironments

    NASA Astrophysics Data System (ADS)

    Rivas, Ioar; Kumar, Prashant; Hagen-Zanker, Alex; Andrade, Maria de Fatima; Slovic, Anne Dorothee; Pritchard, John P.; Geurs, Karst T.

    2017-07-01

    We investigated the determinants of personal exposure concentrations of commuters' to black carbon (BC), ultrafine particle number concentrations (PNC), and particulate matter (PM1, PM2.5 and PM10) in different travel modes. We quantified the contribution of key factors that explain the variation of the previous pollutants in four commuting routes in London, each covered by four transport modes (car, bus, walk and underground). Models were performed for each pollutant, separately to assess the effect of meteorology (wind speed) or ambient concentrations (with either high spatial or temporal resolution). Concentration variations were mainly explained by wind speed or ambient concentrations and to a lesser extent by route and period of the day. In multivariate models with wind speed, the wind speed was the common significant predictor for all the pollutants in the above-ground modes (i.e., car, bus, walk); and the only predictor variable for the PM fractions. Wind speed had the strongest effect on PM during the bus trips, with an increase in 1 m s-1 leading to a decrease in 2.25, 2.90 and 4.98 μg m-3 of PM1, PM2.5 and PM10, respectively. PM2.5 and PM10 concentrations in car trips were better explained by ambient concentrations with high temporal resolution although from a single monitoring station. On the other hand, ambient concentrations with high spatial coverage but lower temporal resolution predicted better the concentrations in bus trips, due to bus routes passing through streets with a high variability of traffic intensity. In the underground models, wind speed was not significant and line and type of windows on the train explained 42% of the variation of PNC and 90% of all PM fractions. Trains in the district line with openable windows had an increase in concentrations of 1 684 cm-3 for PNC and 40.69 μg m-3 for PM2.5 compared with trains that had non-openable windows. The results from this work can be used to target efforts to reduce personal exposures of

  20. Outbreak of sudden cardiac deaths in a tire manufacturing facility: can it be caused by nanoparticles?

    PubMed

    Kim, Eun-A; Park, Jungsun; Kim, Kun-Hyung; Lee, Naroo; Kim, Dae-Seong; Kang, Seong-Kyu

    2012-03-01

    The purpose of this study was to review clinical characteristics and working environments of sudden cardiac death (SCD) cases associated with a tire manufacturer in Korea, and review possible occupational risk factors for cardiovascular disease including nanoparticles (ultrafine particles, UFPs). We reviewed (i) the clinical course of SCD cases and (ii) occupational and non-occupational risk factors including chemicals, the physical work environment, and job characteristics. Possible occupational factors were chemicals, UFPs of rubber fume, a hot environment, shift work, overworking, and noise exposure. The mean diameter of rubber fume (63-73 nm) was (larger than diesel exhaust [12 nm] and outdoor dust [50 nm]). The concentration of carbon disulfide, carbon monoxide and styrene were lower than the limit of detection. Five SCD cases were exposed to shift work and overworking. Most of the cases had several non-occupational factors such as hypertension, overweight and smoking. The diameter of rubber fume was larger than outdoor and the diesel exhaust, the most well known particulate having a causal relationship with cardiovascular disease. The possibility of a causal relation between UFPs of rubber fume and SCD was not supported in this study. However, it is necessary to continue studying the relationship between large sized UFPs and SCD.

  1. Outbreak of Sudden Cardiac Deaths in a Tire Manufacturing Facility: Can It Be Caused by Nanoparticles?

    PubMed Central

    Kim, Eun-A; Kim, Kun-Hyung; Lee, Naroo; Kim, Dae-Seong; Kang, Seong-Kyu

    2012-01-01

    Objectives The purpose of this study was to review clinical characteristics and working environments of sudden cardiac death (SCD) cases associated with a tire manufacturer in Korea, and review possible occupational risk factors for cardiovascular disease including nanoparticles (ultrafine particles, UFPs). Methods We reviewed (i) the clinical course of SCD cases and (ii) occupational and non-occupational risk factors including chemicals, the physical work environment, and job characteristics. Results Possible occupational factors were chemicals, UFPs of rubber fume, a hot environment, shift work, overworking, and noise exposure. The mean diameter of rubber fume (63-73 nm) was (larger than diesel exhaust [12 nm] and outdoor dust [50 nm]). The concentration of carbon disulfide, carbon monoxide and styrene were lower than the limit of detection. Five SCD cases were exposed to shift work and overworking. Most of the cases had several non-occupational factors such as hypertension, overweight and smoking. Conclusion The diameter of rubber fume was larger than outdoor and the diesel exhaust, the most well known particulate having a causal relationship with cardiovascular disease. The possibility of a causal relation between UFPs of rubber fume and SCD was not supported in this study. However, it is necessary to continue studying the relationship between large sized UFPs and SCD. PMID:22953232

  2. Maternal hCG concentrations in early IVF pregnancies: associations with number of cells in the Day 2 embryo and oocytes retrieved.

    PubMed

    Tanbo, T G; Eskild, A

    2015-12-01

    Do number of cells in the transferred cleavage stage embryo and number of oocytes retrieved for IVF influence maternal hCG concentrations in early pregnancies? Compared with transfer of a 2-cell embryo, transfer of a 4-cell embryo results in higher hCG concentrations on Day 12 after transfer, and more than 20 oocytes retrieved were associated with low hCG concentrations. Maternal hCG concentration in very early pregnancy varies considerably among women, but is likely to be an indicator of time since implantation of the embryo into the endometrium, in addition to number and function of trophoblast cells. We followed 1047 pregnancies after IVF/ICSI from oocyte retrieval until Day 12 after embryo transfer. Women were recruited in Norway during the years 2005-2013. Successful pregnancies after transfer of one single embryo that had been cultured for 2 days were included. Maternal hCG was quantified on Day 12 after embryo transfer by chemiluminescence immunoassay, which measures intact hCG and the free β-hCG chain. Information on a successful pregnancy, defined as birth after >16 weeks, was obtained by linkage to the Medical Birth Registry of Norway. Transfer of a 4-cell embryo resulted in higher maternal hCG concentrations compared with transfer of a 2-cell embryo (134.8 versus 87.8 IU/l, P < 0.05). A high number of oocytes retrieved (>20) was associated with low hCG concentrations (P < 0.05). The factors studied explain a limited part of the total variation of hCG concentrations in early pregnancy. Although embryo transfer was performed at the same time after fertilization, we do not know the exact time of implantation. A further limitation to our study is that the number of pregnancies after transfer of a 2-cell embryo was small (27 cases). Number of cells in the transferred embryo and number of oocytes retrieved may influence the conditions and timing for embryo implantation in different ways and thereby influence maternal hCG concentrations. Such knowledge may be

  3. Drivers of Seasonal Variability in Marine Boundary Layer Aerosol Number Concentration Investigated Using a Steady State Approach

    NASA Astrophysics Data System (ADS)

    Mohrmann, Johannes; Wood, Robert; McGibbon, Jeremy; Eastman, Ryan; Luke, Edward

    2018-01-01

    Marine boundary layer (MBL) aerosol particles affect the climate through their interaction with MBL clouds. Although both MBL clouds and aerosol particles have pronounced seasonal cycles, the factors controlling seasonal variability of MBL aerosol particle concentration are not well constrained. In this paper an aerosol budget is constructed representing the effects of wet deposition, free-tropospheric entrainment, primary surface sources, and advection on the MBL accumulation mode aerosol number concentration (Na). These terms are then parameterized, and by assuming that on seasonal time scales Na is in steady state, the budget equation is rearranged to form a diagnostic equation for Na based on observable variables. Using data primarily collected in the subtropical northeast Pacific during the MAGIC campaign (Marine ARM (Atmospheric Radiation Measurement) GPCI (GCSS Pacific Cross-Section Intercomparison) Investigation of Clouds), estimates of both mean summer and winter Na concentrations are made using the simplified steady state model and seasonal mean observed variables. These are found to match well with the observed Na. To attribute the modeled difference between summer and winter aerosol concentrations to individual observed variables (e.g., precipitation rate and free-tropospheric aerosol number concentration), a local sensitivity analysis is combined with the seasonal difference in observed variables. This analysis shows that despite wintertime precipitation frequency being lower than summer, the higher winter precipitation rate accounted for approximately 60% of the modeled seasonal difference in Na, which emphasizes the importance of marine stratocumulus precipitation in determining MBL aerosol concentrations on longer time scales.

  4. Effects of ultrafine particles on the allergic inflammation in the lung of asthmatics: results of a double-blinded randomized cross-over clinical pilot study

    PubMed Central

    2014-01-01

    Background Epidemiological and experimental studies suggest that exposure to ultrafine particles (UFP) might aggravate the allergic inflammation of the lung in asthmatics. Methods We exposed 12 allergic asthmatics in two subgroups in a double-blinded randomized cross-over design, first to freshly generated ultrafine carbon particles (64 μg/m3; 6.1 ± 0.4 × 105 particles/cm3 for 2 h) and then to filtered air or vice versa with a 28-day recovery period in-between. Eighteen hours after each exposure, grass pollen was instilled into a lung lobe via bronchoscopy. Another 24 hours later, inflammatory cells were collected by means of bronchoalveolar lavage (BAL). (Trial registration: NCT00527462) Results For the entire study group, inhalation of UFP by itself had no significant effect on the allergen induced inflammatory response measured with total cell count as compared to exposure with filtered air (p = 0.188). However, the subgroup of subjects, which inhaled UFP during the first exposure, exhibited a significant increase in total BAL cells (p = 0.021), eosinophils (p = 0.031) and monocytes (p = 0.013) after filtered air exposure and subsequent allergen challenge 28 days later. Additionally, the potential of BAL cells to generate oxidant radicals was significantly elevated at that time point. The subgroup that was exposed first to filtered air and 28 days later to UFP did not reveal differences between sessions. Conclusions Our data demonstrate that pre-allergen exposure to UFP had no acute effect on the allergic inflammation. However, the subgroup analysis lead to the speculation that inhaled UFP particles might have a long-term effect on the inflammatory course in asthmatic patients. This should be reconfirmed in further studies with an appropriate study design and sufficient number of subjects. PMID:25204642

  5. Exposure to fine particulate, black carbon, and particle number concentration in transportation microenvironments

    NASA Astrophysics Data System (ADS)

    Morales Betancourt, R.; Galvis, B.; Balachandran, S.; Ramos-Bonilla, J. P.; Sarmiento, O. L.; Gallo-Murcia, S. M.; Contreras, Y.

    2017-05-01

    This research determined intake dose of fine particulate matter (PM2.5), equivalent black carbon (eBC), and number of sub-micron particles (Np) for commuters in Bogotá, Colombia. Doses were estimated through measurements of exposure concentration, a surrogate of physical activity, as well as travel times and speeds. Impacts of travel mode, traffic load, and street configuration on dose and exposure were explored. Three road segments were selected because of their different traffic loads and composition, and dissimilar street configuration. The transport modes considered include active modes (walking and cycling) and motorized modes (bus, car, taxi, and motorcycle). Measurements were performed simultaneously in the available modes at each road segment. High average eBC concentrations were observed throughout the campaign, ranging from 20 to 120 μgm-3 . Commuters in motorized modes experienced significantly higher exposure concentrations than pedestrians and bicyclists. The highest average concentrations of PM2.5, eBC , and Np were measured inside the city's Bus Rapid Transit (BRT) system vehicles. Pedestrians and bicycle users in an open street configuration were exposed to the lowest average concentrations of PM2.5 and eBC , six times lower than those experienced by commuters using the BRT in the same street segment. Pedestrians experienced the highest particulate matter intake dose in the road segments studied, despite being exposed to lower concentrations than commuters in motorized modes. Average potential dose of PM2.5 and eBC per unit length traveled were nearly three times higher for pedestrians in a street canyon configuration compared to commuters in public transport. Slower travel speed and elevated inhalation rates dominate PM dose for pedestrians. The presence of dedicated bike lanes on sidewalks has a significant impact on reducing the exposure concentration for bicyclists compared to those riding in mixed traffic lanes. This study proposes a simple

  6. Ultra Fine Particles from Diesel Engines Induce Vascular Oxidative Stress via JNK Activation

    PubMed Central

    Li, Rongsong; Ning, Zhi; Cui, Jeffery; Khalsa, Bhavraj; Ai, Lisong; Takabe, Wakako; Beebe, Tyler; Majumdar, Rohit; Sioutas, Constantinos; Hsiai, Tzung

    2011-01-01

    Exposure of particulate air pollution is linked to increased incidences of cardiovascular diseases. Ambient ultra fine particles (UFP) from diesel vehicle engines have been shown to be pro-atherogenic in apoE knockout mice and may constitute a major cardiovascular risk in humans. We posited that circulating nano-sized particles from traffic pollution sources induced vascular oxidative stress via JNK activation in endothelial cells. Diesel UFP were collected from a 1998 Kenworth truck. Intra-cellular superoxide assay revealed that these UFP dose-dependently induced superoxide (O2·-) production in human aortic endothelial cells (HAEC). Flow cytometry (FACS) showed that UFP increased MitoSOX Red intensity specific for mitochondrial superoxide. Protein carbonyl content is increased by UFP as an indication of vascular oxidative stress. UFP also up-regulated hemeoxygenase-1 (HO-1) and tissue factor (TF) mRNA expression, and pre-treatment with antioxidant, N-acetyl cysteine (NAC), significantly decreased their expression. Furthermore, UFP transiently activated JNK in HAEC. Treatment with JNK inhibitor SP600125 and silencing of both JNK1 and JNK2 with siRNA inhibited UFP stimulated O2·- production and mRNA expression of HO-1 and TF. Our findings suggest that JNK activation play an important role in UFP-induced oxidative stress and stress response gene expression. PMID:19154785

  7. Drivers of Seasonal Variability in Marine Boundary Layer Aerosol Number Concentration Investigated Using a Steady State Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohrmann, Johannes; Wood, Robert; McGibbon, Jeremy

    Marine boundary layer (MBL) aerosol particles affect the climate through their interaction with MBL clouds. Although both MBL clouds and aerosol particles have pronounced seasonal cycles, the factors controlling seasonal variability of MBL aerosol particle concentration are not well-constrained. In this paper an aerosol budget is constructed representing the effects of wet deposition, free-tropospheric entrainment, primary surface sources, and advection on the MBL accumulation mode aerosol number concentration (N a). These terms are further parameterized, and by assuming that on seasonal timescales N a is in steady state, the budget equation is rearranged to form a diagnostic equation for Nmore » a based on observable variables. Using data primarily collected in the subtropical northeast Pacific during the MAGIC campaign (Marine ARM (Atmospheric Radiation Measurement) GPCI (GCSS Pacific Cross-section Intercomparison) Investigation of Clouds), estimates of both mean summer and winter N a concentrations are made using the simplified steady-state model and seasonal mean observed variables, and are found to match well with the observed N a. To attribute the modeled difference between summer and winter aerosol concentrations to individual observed variables (e.g. precipitation rate, free-tropospheric aerosol number concentration), a local sensitivity analysis is combined with the seasonal difference in observed variables. This analysis shows that despite wintertime precipitation frequency being lower than summer, the higher winter precipitation rate accounted for approximately 60% of the modeled seasonal difference in N a, which emphasizes the importance of marine stratocumulus precipitation in determining MBL aerosol concentrations on longer time scales.« less

  8. Drivers of Seasonal Variability in Marine Boundary Layer Aerosol Number Concentration Investigated Using a Steady State Approach

    DOE PAGES

    Mohrmann, Johannes; Wood, Robert; McGibbon, Jeremy; ...

    2018-01-21

    Marine boundary layer (MBL) aerosol particles affect the climate through their interaction with MBL clouds. Although both MBL clouds and aerosol particles have pronounced seasonal cycles, the factors controlling seasonal variability of MBL aerosol particle concentration are not well-constrained. In this paper an aerosol budget is constructed representing the effects of wet deposition, free-tropospheric entrainment, primary surface sources, and advection on the MBL accumulation mode aerosol number concentration (N a). These terms are further parameterized, and by assuming that on seasonal timescales N a is in steady state, the budget equation is rearranged to form a diagnostic equation for Nmore » a based on observable variables. Using data primarily collected in the subtropical northeast Pacific during the MAGIC campaign (Marine ARM (Atmospheric Radiation Measurement) GPCI (GCSS Pacific Cross-section Intercomparison) Investigation of Clouds), estimates of both mean summer and winter N a concentrations are made using the simplified steady-state model and seasonal mean observed variables, and are found to match well with the observed N a. To attribute the modeled difference between summer and winter aerosol concentrations to individual observed variables (e.g. precipitation rate, free-tropospheric aerosol number concentration), a local sensitivity analysis is combined with the seasonal difference in observed variables. This analysis shows that despite wintertime precipitation frequency being lower than summer, the higher winter precipitation rate accounted for approximately 60% of the modeled seasonal difference in N a, which emphasizes the importance of marine stratocumulus precipitation in determining MBL aerosol concentrations on longer time scales.« less

  9. Spatial & temporal variations of PM10 and particle number concentrations in urban air.

    PubMed

    Johansson, Christer; Norman, Michael; Gidhagen, Lars

    2007-04-01

    The size of particles in urban air varies over four orders of magnitude (from 0.001 microm to 10 microm in diameter). In many cities only particle mass concentrations (PM10, i.e. particles <10 microm diameter) is measured. In this paper we analyze how differences in emissions, background concentrations and meteorology affect the temporal and spatial distribution of PM10 and total particle number concentrations (PNC) based on measurements and dispersion modeling in Stockholm, Sweden. PNC at densely trafficked kerbside locations are dominated by ultrafine particles (<0.1 microm diameter) due to vehicle exhaust emissions as verified by high correlation with NOx. But PNC contribute only marginally to PM10, due to the small size of exhaust particles. Instead wear of the road surface is an important factor for the highest PM10 concentrations observed. In Stockholm, road wear increases drastically due to the use of studded tires and traction sand on streets during winter; up to 90% of the locally emitted PM10 may be due to road abrasion. PM10 emissions and concentrations, but not PNC, at kerbside are controlled by road moisture. Annual mean urban background PM10 levels are relatively uniformly distributed over the city, due to the importance of long range transport. For PNC local sources often dominate the concentrations resulting in large temporal and spatial gradients in the concentrations. Despite these differences in the origin of PM10 and PNC, the spatial gradients of annual mean concentrations due to local sources are of equal magnitude due to the common source, namely traffic. Thus, people in different areas experiencing a factor of 2 different annual PM10 exposure due to local sources will also experience a factor of 2 different exposure in terms of PNC. This implies that health impact studies based solely on spatial differences in annual exposure to PM10 may not separate differences in health effects due to ultrafine and coarse particles. On the other hand

  10. A travel mode comparison of commuters' exposures to air pollutants in Barcelona

    NASA Astrophysics Data System (ADS)

    de Nazelle, Audrey; Fruin, Scott; Westerdahl, Dane; Martinez, David; Ripoll, Anna; Kubesch, Nadine; Nieuwenhuijsen, Mark

    2012-11-01

    Daily commutes may contribute disproportionately to overall daily inhalations of urban air contaminants. Understanding factors that explain variability of exposures during travel, and especially differences across transportation modes, is essential to accurately assess health impacts of traffic emissions and to develop effective mitigating measures. We evaluated exposures and inhaled doses of air pollution and assessed factors that contributed to their variability in different travel modes in Barcelona. Black carbon (BC), ultrafine particles (UFP), carbon monoxide (CO), fine particle mass (PM2.5) and carbon dioxide (CO2) were measured and compared across walk, bike, bus, and car modes for a total of 172 trips made on two different round trip routes. On average, the car mode experienced highest concentrations for all contaminants. In pairwise t-tests between concurrent mode runs, statistically significant differences were found for cars compared to walking and biking. Car-to-walk or car-to-bike concentration ratios ranged from 1.3 for CO2 to 25 for CO and were 2-3 for PM2.5, BC, and UFP. In multivariate analyses, travel mode explained the greatest variability in travel exposures, from 8% for PM2.5 to 70% for CO. Different modal patterns emerged when estimating daily inhaled dose, with active commuters' two to three times greater total inhalation volume during travel producing about equal UFP and BC daily inhaled doses to car commuters and 33-50% higher UFP and BC doses compared to bus commuters. These findings, however, are specific to the bike and pedestrian lanes in this study being immediately adjacent to the roadways measured. Dedicated bike or pedestrian routes away from traffic would lead to lower active travel doses.

  11. Direct comparison of extinction coefficients derived from Mie-scattering lidar and number concentrations of particles, subjective weather report in Japan

    NASA Astrophysics Data System (ADS)

    Shimizu, Atsushi; Sugimoto, Nobuo; Matsui, Ichiro; Nishizawa, Tomoaki

    2015-03-01

    Two components of the lidar extinction coefficient, the dust extinction and the spherical particles extinction, were obtained from observations made by the National Institute for Environmental Studies lidar network in Japan. These two extinctions were compared with the number concentration of particles measured by an optical particle counter, and with subjective weather reports recorded at the nearest meteorological observatories. The dust extinction corresponded well with the number concentration of large particles with diameters as great as 5 μm and during dry conditions with the number concentration of particles larger than 2 μm. The relationship between the spherical particle extinction and the number of small particles was nearly constant under all conditions. Asian dust was sometimes reported by meteorological observatories in the period of lower dust extinction. This indicates contradicting relationship between human-eye based reports and optical characteristics observed by lidars in some cases. The most consistent results between lidar observation and meteorological reports were obtained in dry mist conditions, in which lidars exhibited higher spherical extinction as expected by the definition of the atmospheric phenomenon of dry mist or haze.

  12. Characterizing ultrafine particles and other air pollutants in and around school buses.

    PubMed

    Zhu, Yifang; Zhang, Qunfang

    2014-03-01

    Increasing evidence has demonstrated toxic effects of ultrafine particles (UFP*, diameter < 100 nm). Children are particularly at risk because of their immature respiratory systems and higher breathing rates per body mass. This study aimed to characterize UFP, PM2.5 (particulate matter < or = 2.5 microm in aerodynamic diameter), and other vehicular-emitted pollutants in and around school buses. Four sub-studies were conducted, including: 1. On-road tests to measure in-cabin air pollutant levels while school buses were being driven; 2. Idling tests to determine the contributions of tailpipe emissions from idling school buses to air pollutant levels in and around school buses under different scenarios; 3. Retrofit tests to evaluate the performance of two retrofit systems, a diesel oxidation catalyst (DOC) muffler and a crankcase filtration system (CFS), on reducing tailpipe emissions and in-cabin air pollutant concentrations under idling and driving conditions; and 4. High efficiency particulate air (HEPA) filter air purifier tests to evaluate the effectiveness of in-cabin filtration. In total, 24 school buses were employed to cover a wide range of school buses commonly used in the United States. Real-time air quality measurements included particle number concentration (PNC), fine and UFP size distribution in the size range 7.6-289 nm, PM2.5 mass concentration, black carbon (BC) concentration, and carbon monoxide (CO) and carbon dioxide (CO2) concentrations. For in-cabin measurements, instruments were placed on a platform secured to the rear seats inside the school buses. For all other tests, a second set of instruments was deployed to simultaneously measure the ambient air pollutant levels. For tailpipe emission measurements, the exhaust was diluted and then measured by instruments identical to those used for the in-cabin measurements. The results show that when driving on roads, in-cabin PNC, fine and UFP size distribution, PM2.5, BC, and CO varied by engine age

  13. Vertical profiles of black carbon concentration and particle number size distribution in the North China Plain

    NASA Astrophysics Data System (ADS)

    Ran, L.; Deng, Z.

    2013-12-01

    The vertical distribution of aerosols is of great importance to our understanding in the impacts of aerosols on radiation balance and climate, as well as air quality and public health. To better understand and estimate the effects of atmospheric components including trace gases and aerosols on atmospheric environment and climate, an intensive field campaign, Vertical Observations of trace Gases and Aerosols in the North China Plain (VOGA-NCP), was carried out from late July to early August 2013 over a rural site in the polluted NCP. During the campaign, vertical profiles of black carbon (BC) concentration and particle number size distribution were measured respectively by a micro-Aethalometer and an optical particle counter attached to a tethered balloon within 1000 m height. Meteorological parameters, including temperature, relative humidity, wind speed and wind direction, were measured simultaneously by a radiosonde also attached to the tethered balloon. Preliminary results showed distinct diurnal variations of the vertical distribution of aerosol total number concentration and BC concentration, following the development of the mixing layer. Generally, there was a well mixing of aerosols within the mixing layer and a sharp decrease above the mixing layer. Particularly, a small peak of BC concentrations was observed around 400-500 m height for several profiles. Further analysis would be needed to explain such phenomenon. It was also found that measured vertical profiles of BC using the filter-based method might be affected by the vertical distribution of relative humidity.

  14. Emissions from an international airport increase particle number concentrations 4-fold at 10 km downwind.

    PubMed

    Hudda, Neelakshi; Gould, Tim; Hartin, Kris; Larson, Timothy V; Fruin, Scott A

    2014-06-17

    We measured the spatial pattern of particle number (PN) concentrations downwind from the Los Angeles International Airport (LAX) with an instrumented vehicle that enabled us to cover larger areas than allowed by traditional stationary measurements. LAX emissions adversely impacted air quality much farther than reported in previous airport studies. We measured at least a 2-fold increase in PN concentrations over unimpacted baseline PN concentrations during most hours of the day in an area of about 60 km(2) that extended to 16 km (10 miles) downwind and a 4- to 5-fold increase to 8-10 km (5-6 miles) downwind. Locations of maximum PN concentrations were aligned to eastern, downwind jet trajectories during prevailing westerly winds and to 8 km downwind concentrations exceeded 75 000 particles/cm(3), more than the average freeway PN concentration in Los Angeles. During infrequent northerly winds, the impact area remained large but shifted to south of the airport. The freeway length that would cause an impact equivalent to that measured in this study (i.e., PN concentration increases weighted by the area impacted) was estimated to be 280-790 km. The total freeway length in Los Angeles is 1500 km. These results suggest that airport emissions are a major source of PN in Los Angeles that are of the same general magnitude as the entire urban freeway network. They also indicate that the air quality impact areas of major airports may have been seriously underestimated.

  15. Unsplittable Flow in Paths and Trees and Column-Restricted Packing Integer Programs

    NASA Astrophysics Data System (ADS)

    Chekuri, Chandra; Ene, Alina; Korula, Nitish

    We consider the unsplittable flow problem (UFP) and the closely related column-restricted packing integer programs (CPIPs). In UFP we are given an edge-capacitated graph G = (V,E) and k request pairs R 1, ..., R k , where each R i consists of a source-destination pair (s i ,t i ), a demand d i and a weight w i . The goal is to find a maximum weight subset of requests that can be routed unsplittably in G. Most previous work on UFP has focused on the no-bottleneck case in which the maximum demand of the requests is at most the smallest edge capacity. Inspired by the recent work of Bansal et al. [3] on UFP on a path without the above assumption, we consider UFP on paths as well as trees. We give a simple O(logn) approximation for UFP on trees when all weights are identical; this yields an O(log2 n) approximation for the weighted case. These are the first non-trivial approximations for UFP on trees. We develop an LP relaxation for UFP on paths that has an integrality gap of O(log2 n); previously there was no relaxation with o(n) gap. We also consider UFP in general graphs and CPIPs without the no-bottleneck assumption and obtain new and useful results.

  16. A study on the relationship between mass concentrations, chemistry and number size distribution of urban fine aerosols in Milan, Barcelona and London

    NASA Astrophysics Data System (ADS)

    Rodríguez, S.; van Dingenen, R.; Putaud, J.-P.; Dell'Acqua, A.; Pey, J.; Querol, X.; Alastuey, A.; Chenery, S.; Ho, K.-F.; Harrison, R. M.; Tardivo, R.; Scarnato, B.; Gianelle, V.

    2007-01-01

    A physicochemical characterization of the urban fine aerosol (aerosol number size distribution, chemical composition and mass concentrations) in Milan, Barcelona and London is presented in this article. The objective is to obtain a comprehensive picture on the involvement of the microphysical processes of the aerosol dynamic in the: 1) regular evolution of the urban aerosol (daily, weekly and seasonal basis) and in the day-to-day variations (from clean-air to pollution-events), and 2) link between "aerosol chemistry and mass concentrations" with the "number size distribution". The mass concentrations of the fine PM2.5 aerosol exhibit a high correlation with the number concentration of particles >100 nm (which only accounts for <20% of the total number concentration N of fine aerosols) and do not correlate with the number of particles <100 nm ("ultrafine particles", which accounts for >80% of fine particles). Organic matter (OM) and black-carbon (BC) are the only aerosol components showing a significant correlation with ultrafine particles (attributed to vehicles emissions), whereas ammonium-nitrate, ammonium-sulphate and also OM and BC correlate with N>100(nm) (attributed to gas-to-particle transformation mechanisms and some primary emissions). Time series of the aerosol DpN diameter (dN/dlogD mode), mass PM2.5 concentrations and number N>100(nm) concentrations, exhibit correlated day-to-day variations which point to a significant involvement of condensation of semi-volatile compounds during urban pollution events. This agrees with the fact that ammonium-nitrate is the component exhibiting the highest increases from mid-to-high pollution episodes, when the highest DpN increases are observed. The results indicates that "fine PM2.5 particles urban pollution events" tend to occur when condensation processes have made particles grow enough to produce significant concentrations of N>100(nm). In contrast, because the low contribution of ultrafine particles to the fine

  17. Exposure to ultrafine particles and respiratory hospitalisations in five European cities.

    PubMed

    Samoli, Evangelia; Andersen, Zorana Jovanovic; Katsouyanni, Klea; Hennig, Frauke; Kuhlbusch, Thomas A J; Bellander, Tom; Cattani, Giorgio; Cyrys, Josef; Forastiere, Francesco; Jacquemin, Bénédicte; Kulmala, Markku; Lanki, Timo; Loft, Steffen; Massling, Andreas; Tobias, Aurelio; Stafoggia, Massimo

    2016-09-01

    Epidemiological evidence on the associations between exposure to ultrafine particles (UFP), with aerodynamic electrical mobility diameters <100 nm, and health is limited. We gathered data on UFP from five European cities within 2001-2011 to investigate associations between short-term changes in concentrations and respiratory hospitalisations.We applied city-specific Poisson regression models and combined city-specific estimates to obtain pooled estimates. We evaluated the sensitivity of our findings to co-pollutant adjustment and investigated effect modification patterns by period of the year, age at admission and specific diagnoses.Our results for the whole time period do not support an association between UFP and respiratory hospitalisations, although we found suggestive associations among those 0-14 years old. We nevertheless report consistent adverse effect estimates during the warm period of the year, statistically significant after lag 2 when an increase by 10 000 particles per cm(3) was associated with a 4.27% (95% CI 1.68-6.92%) increase in hospitalisations. These effect estimates were robust to particles' mass or gaseous pollutants adjustment.Considering that our findings during the warm period may reflect better exposure assessment and that the main source of non-soluble UFP in urban areas is traffic, our results call for improved regulation of traffic emissions. Copyright ©ERS 2016.

  18. Emissions from an International Airport Increase Particle Number Concentrations 4-fold at 10 km Downwind

    PubMed Central

    2014-01-01

    We measured the spatial pattern of particle number (PN) concentrations downwind from the Los Angeles International Airport (LAX) with an instrumented vehicle that enabled us to cover larger areas than allowed by traditional stationary measurements. LAX emissions adversely impacted air quality much farther than reported in previous airport studies. We measured at least a 2-fold increase in PN concentrations over unimpacted baseline PN concentrations during most hours of the day in an area of about 60 km2 that extended to 16 km (10 miles) downwind and a 4- to 5-fold increase to 8–10 km (5–6 miles) downwind. Locations of maximum PN concentrations were aligned to eastern, downwind jet trajectories during prevailing westerly winds and to 8 km downwind concentrations exceeded 75 000 particles/cm3, more than the average freeway PN concentration in Los Angeles. During infrequent northerly winds, the impact area remained large but shifted to south of the airport. The freeway length that would cause an impact equivalent to that measured in this study (i.e., PN concentration increases weighted by the area impacted) was estimated to be 280–790 km. The total freeway length in Los Angeles is 1500 km. These results suggest that airport emissions are a major source of PN in Los Angeles that are of the same general magnitude as the entire urban freeway network. They also indicate that the air quality impact areas of major airports may have been seriously underestimated. PMID:24871496

  19. Investigation of Aerosol Surface Area Estimation from Number and Mass Concentration Measurements: Particle Density Effect.

    PubMed

    Ku, Bon Ki; Evans, Douglas E

    2012-04-01

    For nanoparticles with nonspherical morphologies, e.g., open agglomerates or fibrous particles, it is expected that the actual density of agglomerates may be significantly different from the bulk material density. It is further expected that using the material density may upset the relationship between surface area and mass when a method for estimating aerosol surface area from number and mass concentrations (referred to as "Maynard's estimation method") is used. Therefore, it is necessary to quantitatively investigate how much the Maynard's estimation method depends on particle morphology and density. In this study, aerosol surface area estimated from number and mass concentration measurements was evaluated and compared with values from two reference methods: a method proposed by Lall and Friedlander for agglomerates and a mobility based method for compact nonspherical particles using well-defined polydisperse aerosols with known particle densities. Polydisperse silver aerosol particles were generated by an aerosol generation facility. Generated aerosols had a range of morphologies, count median diameters (CMD) between 25 and 50 nm, and geometric standard deviations (GSD) between 1.5 and 1.8. The surface area estimates from number and mass concentration measurements correlated well with the two reference values when gravimetric mass was used. The aerosol surface area estimates from the Maynard's estimation method were comparable to the reference method for all particle morphologies within the surface area ratios of 3.31 and 0.19 for assumed GSDs 1.5 and 1.8, respectively, when the bulk material density of silver was used. The difference between the Maynard's estimation method and surface area measured by the reference method for fractal-like agglomerates decreased from 79% to 23% when the measured effective particle density was used, while the difference for nearly spherical particles decreased from 30% to 24%. The results indicate that the use of particle density

  20. Understanding Ice Supersaturation, Particle Growth, and Number Concentration in Cirrus Clouds

    NASA Technical Reports Server (NTRS)

    Comstock, Jennifer M.; Lin, Ruei-Fong; Starr, David O'C.; Yang, Ping

    2008-01-01

    Many factors control the ice supersaturation and microphysical properties in cirrus clouds. We explore the effects of dynamic forcing, ice nucleation mechanisms, and ice crystal growth rate on the evolution and distribution of water vapor and cloud properties in nighttime cirrus clouds using a one-dimensional cloud model with bin microphysics and remote sensing measurements obtained at the Department of Energy's Atmospheric Radiation Measurement (ARM) Climate Research Facility located near Lamont, OK. We forced the model using both large-scale vertical ascent and, for the first time, mean mesoscale velocity derived from radar Doppler velocity measurements. Both heterogeneous and homogeneous nucleation processes are explored, where a classical theory heterogeneous scheme is compared with empirical representations. We evaluated model simulations by examining both bulk cloud properties and distributions of measured radar reflectivity, lidar extinction, and water vapor profiles, as well as retrieved cloud microphysical properties. Our results suggest that mesoscale variability is the primary mechanism needed to reproduce observed quantities. Model sensitivity to the ice growth rate is also investigated. The most realistic simulations as compared with observations are forced using mesoscale waves, include fast ice crystal growth, and initiate ice by either homogeneous or heterogeneous nucleation. Simulated ice crystal number concentrations (tens to hundreds particles per liter) are typically two orders of magnitude smaller than previously published results based on aircraft measurements in cirrus clouds, although higher concentrations are possible in isolated pockets within the nucleation zone.

  1. Total deposition of ultrafine particles in the lungs of healthy men and women: experimental and theoretical results.

    PubMed

    Sturm, Robert

    2016-06-01

    Inhaled ultrafine particles (UFP) may induce greater adverse respiratory effects than larger particles occurring in the ambient atmosphere. Due to this potential of UFP to act as triggers for diverse lung injuries medical as well as physical research has been increasingly focused on the exact deposition behavior of the particles in lungs of various probands. Main purpose of the present study was the presentation of experimental and theoretical data of total, regional, and local UFP deposition in the lungs of men and women. Both experiments and theoretical simulations were carried out by using particle sizes of 0.04, 0.06, 0.08, and 0.10 µm [number median diameters (NMD)]. Inhalation of UFP took place by application of predefined tidal volumes (500, 750, and 1,000 mL) and respiratory flow rates (150, 250, 375, and 500 mL·s(-1)). For male subjects a functional residual capacity (FRC) of 3,911±892 mL was measured, whereas female probands had a FRC of 3,314±547 mL. Theoretical predictions were based on (I) a stochastic model of the tracheobronchial tree; (II) particle transport computations according to a random walk algorithm; and (III) empirical formulae for the description of UFP deposition. Total deposition fractions (TDF) are marked by a continuous diminution with increasing particle size. Whilst particles measuring 0.04 µm in size deposit in the respiratory tract by 40-70%, particles with a size of 0.10 µm exhibit deposition values ranging from 20% to 45%. Except for the largest particles studied here TDF of female probands are higher than those obtained for male probands. Differences between experimental and theoretical results are most significant for 0.10 µm particles, but never exceed 20%. Predictions of regional (extrathoracic, tracheobronchial, alveolar) UFP deposition show clearly that females tend to develop higher tracheobronchial and alveolar deposition fractions than males. This discrepancy is also confirmed by airway generation

  2. Laboratory and on-road evaluations of cabin air filters using number and surface area concentration monitors.

    PubMed

    Qi, Chaolong; Stanley, Nick; Pui, David Y H; Kuehn, Thomas H

    2008-06-01

    An automotive cabin air filter's effectiveness for removing airborne particles was determined both in a laboratory wind tunnel and in vehicle on-road tests. The most penetrating particle size for the test filter was approximately 350 nm, where the filtration efficiency was 22.9 and 17.4% at medium and high fan speeds, respectively. The filtration efficiency increased for smaller particles and was 43.9% for 100 nm and 72.0% for 20 nm particles at a medium fan speed. We determined the reduction in passenger exposure to particles while driving in freeway traffic caused by a vehicle ventilation system with a cabin air filter installed. Both particle number and surface area concentration measurements were made inside the cabin and in the surrounding air. At medium fan speed, the number and surface area concentration-based exposure reductions were 65.6 +/- 6.0% and 60.6 +/- 9.4%, respectively. To distinguish the exposure reduction contribution from the filter alone and the remainder of the ventilation system, we also performed tests with and without the filter in place using the surface area monitors. The ventilation system operating in the recirculation mode with the cabin air filter installed provided the maximum protection, reducing the cabin particle concentration exponentially over time and usually taking only 3 min to reach 10 microm2/cm3 (a typical office air condition) under medium fan speed.

  3. Occupational Exposure to Cobalt and Tungsten in the Swedish Hard Metal Industry: Air Concentrations of Particle Mass, Number, and Surface Area

    PubMed Central

    Bryngelsson, Ing-Liss; Pettersson, Carin; Husby, Bente; Arvidsson, Helena; Westberg, Håkan

    2016-01-01

    Exposure to cobalt in the hard metal industry entails severe adverse health effects, including lung cancer and hard metal fibrosis. The main aim of this study was to determine exposure air concentration levels of cobalt and tungsten for risk assessment and dose–response analysis in our medical investigations in a Swedish hard metal plant. We also present mass-based, particle surface area, and particle number air concentrations from stationary sampling and investigate the possibility of using these data as proxies for exposure measures in our study. Personal exposure full-shift measurements were performed for inhalable and total dust, cobalt, and tungsten, including personal real-time continuous monitoring of dust. Stationary measurements of inhalable and total dust, PM2.5, and PM10 was also performed and cobalt and tungsten levels were determined, as were air concentration of particle number and particle surface area of fine particles. The personal exposure levels of inhalable dust were consistently low (AM 0.15mg m−3, range <0.023–3.0mg m−3) and below the present Swedish occupational exposure limit (OEL) of 10mg m−3. The cobalt levels were low as well (AM 0.0030mg m−3, range 0.000028–0.056mg m−3) and only 6% of the samples exceeded the Swedish OEL of 0.02mg m−3. For continuous personal monitoring of dust exposure, the peaks ranged from 0.001 to 83mg m−3 by work task. Stationary measurements showed lower average levels both for inhalable and total dust and cobalt. The particle number concentration of fine particles (AM 3000 p·cm−3) showed the highest levels at the departments of powder production, pressing and storage, and for the particle surface area concentrations (AM 7.6 µm2·cm−3) similar results were found. Correlating cobalt mass-based exposure measurements to cobalt stationary mass-based, particle area, and particle number concentrations by rank and department showed significant correlations for all measures except for particle

  4. Ultrafine particles and platelet activation in patients with coronary heart disease – results from a prospective panel study

    PubMed Central

    Rückerl, Regina; Phipps, Richard P; Schneider, Alexandra; Frampton, Mark; Cyrys, Josef; Oberdörster, Günther; Wichmann, H Erich; Peters, Annette

    2007-01-01

    Background Epidemiological studies on health effects of air pollution have consistently shown adverse cardiovascular effects. Toxicological studies have provided evidence for thrombogenic effects of particles. A prospective panel study in a susceptible population was conducted in Erfurt, Germany, to study the effects of daily changes in ambient particles on various blood cells and soluble CD40ligand (sCD40L, also known as CD154), a marker for platelet activation that can cause increased coagulation and inflammation. Blood cells and plasma sCD40L levels were repeatedly measured in 57 male patients with coronary heart disease (CHD) during winter 2000/2001. Fixed effects linear regression models were applied, adjusting for trend, weekday and meteorological parameters. Hourly data on ultrafine particles (UFP, number concentration of particles from 0.01 to 0.1 μm), mass concentration of particles less than 10 and 2.5 μm in diameter (PM10, PM2.5), accumulation mode particle counts (AP, 0.1–1.0 μm), elemental and organic carbon, gaseous pollutants and meteorological data were collected at central monitoring sites. Results An immediate increase in plasma sCD40L was found in association with UFP and AP (% change from geometric mean: 7.1; CI: [0.1, 14.5] and 6.9; CI: [0.5, 13.8], respectively). Platelet counts decreased in association with UFP showing an immediate, a three days delayed (lag 3) and a 5-day average response (% change from the mean: -1.8; CI: [-3.4,-0.2]; -2.4; CI: [-4.5,-0.3] and -2.2; CI: [-4.0,-0.3] respectively). Conclusion The increased plasma sCD40L levels support the hypothesis that higher levels of ambient air pollution lead to an inflammatory response in patients with CHD thus providing a possible explanation for the observed association between air pollution and cardiovascular morbidity and mortality in susceptible parts of the population. PMID:17241467

  5. Fuel-Flexible Gasification-Combustion Technology for Production of H2 and Sequestration-Ready CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parag Kulkarni; Jie Guan; Raul Subia

    hydrogen and electricity for a full-scale UFP plant. These costs were benchmarked with IGCC polygen plants with similar level of CO{sub 2} capture. Based on the promising economic analysis comparison results (performed with the help from Worley Parsons), GE recommended a 'Go' decision in April 2006 to continue the experimental investigation of the UFP technology to address the remaining risks i.e. solids lifetime and the impact of impurities in the coal on overall system. Solids attrition and lifetime risk was addressed via bench-scale experiments that monitor solids performance over time and by assessing materials interactions at operating conditions. The product gas under the third reactor (high-temperature vitiated air) operating conditions was evaluated to assess the concentration of particulates, pollutants and other impurities relative to the specifications required for gas turbine feed streams. During this investigation, agglomeration of solids used in the UFP process was identified as a serious risk that impacts the lifetime of the solids and in turn feasibility of the UFP technology. The main causes of the solids agglomeration were the combination of oxygen transfer material (OTM) reduction at temperatures {approx}1000 C and interaction between OTM and CO{sub 2} absorbing material (CAM) at high operating temperatures (>1200 C). At the end of phase II, in March 2008, GEGR recommended a 'No-go' decision for taking the UFP technology to the next level of development, i.e. development of a 3-5 MW prototype system, at this time. GEGR further recommended focused materials development research programs on improving the performance and lifetime of solids materials used in UFP or chemical looping technologies. The scale-up activities would be recommended only after mitigating the risks involved with the agglomeration and overall lifetime of the solids. This is the final report for the phase II of the DOE-funded Vision 21 program entitled 'Fuel-Flexible Gasification

  6. The chemical composition of ultrafine particles and associated biological effects at an alpine town impacted by wood burning.

    PubMed

    Corsini, Emanuela; Vecchi, Roberta; Marabini, Laura; Fermo, Paola; Becagli, Silvia; Bernardoni, Vera; Caruso, Donatella; Corbella, Lorenza; Dell'Acqua, Manuela; Galli, Corrado L; Lonati, Giovanni; Ozgen, Senem; Papale, Angela; Signorini, Stefano; Tardivo, Ruggero; Valli, Gianluigi; Marinovich, Marina

    2017-06-01

    This work is part of the TOBICUP (TOxicity of BIomass Combustion generated Ultrafine Particles) project which aimed at providing the composition of ultrafine particles (UFPs, i.e. particles with aerodynamic diameter, d ae , lower than 100nm) emitted by wood combustion and elucidating the related toxicity. Results here reported are from two ambient monitoring campaigns carried out at an alpine town in Northern Italy, where wood burning is largely diffused for domestic heating in winter. Wintertime and summertime UFP samples were analyzed to assess their chemical composition (i.e. elements, ions, total carbon, anhydrosugars, and polycyclic aromatic hydrocarbons) and biological activity. The induction of the pro-inflammatory cytokine interleukin-8 (IL-8) by UFPs was investigated in two human cells lines (A549 and THP-1) and in human peripheral blood leukocytes. In addition, UFP-induced oxidative stress and genotoxicity were investigated in A549 cells. Ambient UFP-related effects were compared to those induced by traffic-emitted particles (DEP) taken from the NIES reference material "vehicle exhaust particulates". Ambient air UFPs induced a dose-related IL-8 release in both A549 and THP-1 cells; the effect was more relevant on summer samples and in general THP-1 cells were more sensitive than A549 cells. On a weight basis our data did not support a higher biological activity of ambient UFPs compared to DEP. The production of IL-8 in the whole blood assay indicated that UFPs reached systemic circulation and activated blood leukocytes. Comet assay and γ-H2AX evaluation showed a significant DNA damage especially in winter UFPs samples compared to control samples. Our study showed that ambient UFPs can evoke a pulmonary inflammatory response by inducing a dose-related IL-8 production and DNA damage, with different responses to UFP samples collected in the summer and winter periods. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Using models to interpret the impact of roadside barriers on near-road air quality

    NASA Astrophysics Data System (ADS)

    Amini, Seyedmorteza; Ahangar, Faraz Enayati; Schulte, Nico; Venkatram, Akula

    2016-08-01

    The question this paper addresses is whether semi-empirical dispersion models based on data from controlled wind tunnel and tracer experiments can describe data collected downwind of a sound barrier next to a real-world urban highway. Both models are based on the mixed wake model described in Schulte et al. (2014). The first neglects the effects of stability on dispersion, and the second accounts for reduced entrainment into the wake of the barrier under unstable conditions. The models were evaluated with data collected downwind of a kilometer-long barrier next to the I-215 freeway running next to the University of California campus in Riverside. The data included measurements of 1) ultrafine particle (UFP) concentrations at several distances from the barrier, 2) micrometeorological variables upwind and downwind of the barrier, and 3) traffic flow separated by automobiles and trucks. Because the emission factor for UFP is highly uncertain, we treated it as a model parameter whose value is obtained by fitting model estimates to observations of UFP concentrations measured at distances where the barrier impact is not dominant. Both models provide adequate descriptions of both the magnitude and the spatial variation of observed concentrations. The good performance of the models reinforces the conclusion from Schulte et al. (2014) that the presence of the barrier is equivalent to shifting the line sources on the road upwind by a distance of about HU/u∗ where H is the barrier height, U is the wind velocity at half of the barrier height, and u∗ is the friction velocity. The models predict that a 4 m barrier results in a 35% reduction in average concentration within 40 m (10 times the barrier height) of the barrier, relative to the no-barrier site. This concentration reduction is 55% if the barrier height is doubled.

  8. Particle exposure and inhaled dose during commuting in Singapore

    NASA Astrophysics Data System (ADS)

    Tan, Sok Huang; Roth, Matthias; Velasco, Erik

    2017-12-01

    Exposure concentration and inhaled dose of particles during door-to-door trips walking and using motorized transport modes (subway, bus, taxi) are evaluated along a selected route in a commercial district of Singapore. Concentrations of particles smaller than 2.5 μm in size (PM2.5), black carbon, particle-bound polycyclic aromatic hydrocarbons, number of particles, active surface area and carbon monoxide have been measured in-situ using portable instruments. Simultaneous measurements were conducted at a nearby park to capture the background concentrations. The heart rate of the participants was monitored during the measurements as a proxy of the inhalation rate used to calculate the inhaled dose of particles. All measured metrics were highest and well above background levels during walking. No significant difference was observed in the exposure concentration of PM2.5 for the three motorized transport modes, unlike for the metrics associated with ultrafine particles (UFP). The concentration of these freshly emitted particles was significantly lower on subway trips. The absence of combustion sources, use of air conditioning and screen doors at station platforms are effective measures to protect passengers' health. For other transport modes, sections of trips close to accelerating and idling vehicles, such as bus stops, traffic junctions and taxi stands, represent hotspots of particles. Reducing the waiting time at such locations will lower pollutants exposure and inhaled dose during a commute. After taking into account the effect of inhalation and travel duration when calculating dose, the health benefit of commuting by subway for this particular district of Singapore became even more evident. For example, pedestrians breathe in 2.6 and 3.2 times more PM2.5 and UFP, respectively than subway commuters. Public buses were the second best alternative. Walking emerged as the worst commuting mode in terms of particle exposure and inhaled dose.

  9. Investigation of Aerosol Surface Area Estimation from Number and Mass Concentration Measurements: Particle Density Effect

    PubMed Central

    Ku, Bon Ki; Evans, Douglas E.

    2015-01-01

    For nanoparticles with nonspherical morphologies, e.g., open agglomerates or fibrous particles, it is expected that the actual density of agglomerates may be significantly different from the bulk material density. It is further expected that using the material density may upset the relationship between surface area and mass when a method for estimating aerosol surface area from number and mass concentrations (referred to as “Maynard’s estimation method”) is used. Therefore, it is necessary to quantitatively investigate how much the Maynard’s estimation method depends on particle morphology and density. In this study, aerosol surface area estimated from number and mass concentration measurements was evaluated and compared with values from two reference methods: a method proposed by Lall and Friedlander for agglomerates and a mobility based method for compact nonspherical particles using well-defined polydisperse aerosols with known particle densities. Polydisperse silver aerosol particles were generated by an aerosol generation facility. Generated aerosols had a range of morphologies, count median diameters (CMD) between 25 and 50 nm, and geometric standard deviations (GSD) between 1.5 and 1.8. The surface area estimates from number and mass concentration measurements correlated well with the two reference values when gravimetric mass was used. The aerosol surface area estimates from the Maynard’s estimation method were comparable to the reference method for all particle morphologies within the surface area ratios of 3.31 and 0.19 for assumed GSDs 1.5 and 1.8, respectively, when the bulk material density of silver was used. The difference between the Maynard’s estimation method and surface area measured by the reference method for fractal-like agglomerates decreased from 79% to 23% when the measured effective particle density was used, while the difference for nearly spherical particles decreased from 30% to 24%. The results indicate that the use of

  10. Fuel-Flexible Gasification-Combustion Technology for Production of H2 and Sequestration-Ready CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Parag Kulkarni; Wei Wei

    will be benchmarked with IGCC polygen costs for plants of similar size. Sorbent attrition and lifetime will be addressed via bench-scale experiments that monitor sorbent performance over time and by assessing materials interactions at operating conditions. The product gas from the third reactor (high-temperature vitiated air) will be evaluated to assess the concentration of particulates, pollutants and other impurities relative to the specifications required for gas turbine feed streams. This is the eighteenth quarterly technical progress report for the UFP program, which is supported by U.S. DOE NETL (Contract No. DE-FC26-00FT40974) and GE. This report summarizes program accomplishments for the Phase II period starting July 01, 2005 and ending September 30, 2005. The report includes an introduction summarizing the UFP technology, main program tasks, and program objectives; it also provides a summary of program activities and accomplishments covering progress in tasks including process modeling, scale-up and economic analysis.« less

  11. Ultrafine particles generated from coloring with scented markers in the presence of ozone.

    PubMed

    Fung, C-C D; Shu, S; Zhu, Y

    2014-10-01

    High concentrations of ultrafine particles (UFPs) have been previously reported during school art activities. This is possibly due to secondary organic aerosols (SOAs) formed from reactions between ozone and volatile organic compounds emitted from art products. Four brands of markers, three scented and one unscented, were tested inside a stainless steel chamber at eight different ozone concentrations between 0 and 300 ppb. Out of the 32 tested markers, only the lemon- and orange-scented markers from one brand reacted with ozone to form UFPs. Limonene, pinene, and several other terpenes were identified as ingredients of ink in SOA-forming markers. Coloring with one lemon-scented marker for 1 min without ozone generated on average approximately 26 ± 4 ppb of limonene inside the chamber. At 150 ppb ozone, using one lemon marker for 1 min formed on average 7.7 × 10(10) particles. The particle size distribution indicated an initial mode of 15 nm which grew to 40 nm. At 50 ppb ozone and below, no significant SOA formation occurred. The number of particles formed is moderately correlated with the mass of ink used (R(2)  = 0.68). Based on these data, scented markers are not likely a strong source of SOA under normal indoor ozone levels. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Ambient ultrafine particles reduce endothelial nitric oxide production via S-glutathionylation of eNOS.

    PubMed

    Du, Yunfeng; Navab, Mohamad; Shen, Melody; Hill, James; Pakbin, Payam; Sioutas, Constantinos; Hsiai, Tzung K; Li, Rongsong

    2013-07-05

    Exposure to airborne particulate pollutants is intimately linked to vascular oxidative stress and inflammatory responses with clinical relevance to atherosclerosis. Particulate matter (PM) has been reported to induce endothelial dysfunction and atherosclerosis. Here, we tested whether ambient ultrafine particles (UFP, diameter <200 nm) modulate eNOS activity in terms of nitric oxide (NO) production via protein S-glutathionylation. Treatment of human aortic endothelial cells (HAEC) with UFP significantly reduced NO production. UFP-mediated reduction in NO production was restored in the presence of JNK inhibitor (SP600125), NADPH oxidase inhibitor (Apocynin), anti-oxidant (N-acetyl cysteine), and superoxide dismutase mimetics (Tempol and MnTMPyP). UFP exposure increased the GSSG/GSH ratio and eNOS S-glutathionylation, whereas over-expression of Glutaredoxin-1 (to inhibit S-glutathionylation) restored UFP-mediated reduction in NO production by nearly 80%. Thus, our findings suggest that eNOS S-glutathionylation is a potential mechanism underlying ambient UFP-induced reduction of NO production. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Ambient ultrafine particles reduce endothelial nitric oxide production via S-glutathionylation of eNOS

    PubMed Central

    Du, Yunfeng; Navab, Mohamad; Shen, Melody; Hill, James; Pakbin, Payam; Sioutas, Constantinos; Hsiai, Tzung; Li, Rongsong

    2013-01-01

    Exposure to airborne particulate pollutants is intimately linked to vascular oxidative stress and inflammatory responses with clinical relevance to atherosclerosis. Particulate matter (PM) has been reported to induce endothelial dysfunction and atherosclerosis. Here, we tested whether ambient ultrafine particles (UFP, diameter < 200 nm) modulate eNOS activity in terms of nitric oxide (NO) production via protein S-glutathionylation. Treatment of human aortic endothelial cells (HAEC) with UFP significantly reduced NO production. UFP-mediated reduction in NO production was restored in the presence of JNK inhibitor (SP600125), NADPH oxidase inhibitor (Apocynin), anti-oxidant (N-acetyl cysteine), and superoxide dismutase mimetics (Tempol and MnTMPyP). UFP exposure increased the GSSG/GSH ratio and eNOS S-glutathionylation, whereas over-expression of Glutaredoxin-1 (to inhibit S-glutathionylation) restored UFP-mediated reduction in NO production by nearly 80%. Thus, our findings suggest that eNOS S-glutathionylation is a potential mechanism underlying ambient UFP-induced reduction of NO production. PMID:23751346

  14. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  15. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  16. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  17. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  18. Apportionment of motor vehicle emissions from fast changes in number concentration and chemical composition of ultrafine particles near a roadway intersection.

    PubMed

    Klems, Joseph P; Pennington, M Ross; Zordan, Christopher A; McFadden, Lauren; Johnston, Murray V

    2011-07-01

    High frequency spikes in ultrafine number concentration near a roadway intersection arise from motor vehicles that accelerate after a red light turns green. The present work describes a method to determine the contribution of motor vehicles to the total ambient ultrafine particle mass by correlating these number concentration spikes with fast changes in ultrafine particle chemical composition measured with the nano aerosol mass spectrometer, NAMS. Measurements were performed at an urban air quality monitoring site in Wilmington, Delaware during the summer and winter of 2009. Motor vehicles were found to contribute 48% of the ultrafine particle mass in the winter measurement period, but only 16% of the ultrafine particle mass in the summer period. Chemical composition profiles and contributions to the ultrafine particle mass of spark vs diesel vehicles were estimated by correlating still camera images, chemical composition and spike contribution at each time interval.. The spark and diesel contributions were roughly equal, but the uncertainty in the split was large. The distribution of emissions from individual vehicles was determined by correlating camera images with the spike contribution to particle number concentration at each time interval. A small percentage of motor vehicles were found to emit a disproportionally large concentration of ultrafine particles, and these high emitters included both spark ignition and diesel vehicles.

  19. Scale-up of a Luminescent Solar Concentrator-Based Photomicroreactor via Numbering-up.

    PubMed

    Zhao, Fang; Cambié, Dario; Janse, Jeroen; Wieland, Eric W; Kuijpers, Koen P L; Hessel, Volker; Debije, Michael G; Noël, Timothy

    2018-01-02

    The use of solar energy to power chemical reactions is a long-standing dream of the chemical community. Recently, visible-light-mediated photoredox catalysis has been recognized as the ideal catalytic transformation to convert solar energy into chemical bonds. However, scaling photochemical transformations has been extremely challenging due to Bouguer-Lambert-Beer law. Recently, we have pioneered the development of luminescent solar concentrator photomicroreactors (LSC-PMs), which display an excellent energy efficiency. These devices harvest solar energy, convert the broad solar energy spectrum to a narrow-wavelength region, and subsequently waveguide the re-emitted photons to the reaction channels. Herein, we report on the scalability of such LSC-PMs via a numbering-up strategy. Paramount in our work was the use of molds that were fabricated via 3D printing. This allowed us to rapidly produce many different prototypes and to optimize experimentally key design aspects in a time-efficient fashion. Reactors up to 32 parallel channels have been fabricated that display an excellent flow distribution using a bifurcated flow distributor (standard deviations below 10%). This excellent flow distribution was crucial to scale up a model reaction efficiently, displaying yields comparable to those obtained in a single-channel device. We also found that interchannel spacing is an important and unique design parameter for numbered-up LSC-PMs, which influences greatly the photon flux experienced within the reaction channels.

  20. Scale-up of a Luminescent Solar Concentrator-Based Photomicroreactor via Numbering-up

    PubMed Central

    2017-01-01

    The use of solar energy to power chemical reactions is a long-standing dream of the chemical community. Recently, visible-light-mediated photoredox catalysis has been recognized as the ideal catalytic transformation to convert solar energy into chemical bonds. However, scaling photochemical transformations has been extremely challenging due to Bouguer–Lambert–Beer law. Recently, we have pioneered the development of luminescent solar concentrator photomicroreactors (LSC-PMs), which display an excellent energy efficiency. These devices harvest solar energy, convert the broad solar energy spectrum to a narrow-wavelength region, and subsequently waveguide the re-emitted photons to the reaction channels. Herein, we report on the scalability of such LSC-PMs via a numbering-up strategy. Paramount in our work was the use of molds that were fabricated via 3D printing. This allowed us to rapidly produce many different prototypes and to optimize experimentally key design aspects in a time-efficient fashion. Reactors up to 32 parallel channels have been fabricated that display an excellent flow distribution using a bifurcated flow distributor (standard deviations below 10%). This excellent flow distribution was crucial to scale up a model reaction efficiently, displaying yields comparable to those obtained in a single-channel device. We also found that interchannel spacing is an important and unique design parameter for numbered-up LSC-PMs, which influences greatly the photon flux experienced within the reaction channels. PMID:29333350

  1. Longitudinal associations of long-term exposure to ultrafine particles with blood pressure and systemic inflammation in Puerto Rican adults.

    PubMed

    Corlin, Laura; Woodin, Mark; Hart, Jaime E; Simon, Matthew C; Gute, David M; Stowell, Joanna; Tucker, Katherine L; Durant, John L; Brugge, Doug

    2018-04-05

    Few longitudinal studies have examined the association between ultrafine particulate matter (UFP, particles < 0.1 μm aerodynamic diameter) exposure and cardiovascular disease (CVD) risk factors. We used data from 791 adults participating in the longitudinal Boston Puerto Rican Health Study (Massachusetts, USA) between 2004 and 2015 to assess whether UFP exposure was associated with blood pressure and high sensitivity C-reactive protein (hsCRP, a biomarker of systemic inflammation). Residential annual average UFP exposure (measured as particle number concentration, PNC) was assigned using a model accounting for spatial and temporal trends. We also adjusted PNC values for participants' inhalation rate to obtain the particle inhalation rate (PIR) as a secondary exposure measure. Multilevel linear models with a random intercept for each participant were used to examine the association of UFP with blood pressure and hsCRP. Overall, in adjusted models, an inter-quartile range increase in PNC was associated with increased hsCRP (β = 6.8; 95% CI = - 0.3, 14.0%) but not with increased systolic blood pressure (β = 0.96; 95% CI = - 0.33, 2.25 mmHg), pulse pressure (β = 0.70; 95% CI = - 0.27, 1.67 mmHg), or diastolic blood pressure (β = 0.55; 95% CI = - 0.20, 1.30 mmHg). There were generally stronger positive associations among women and never smokers. Among men, there were inverse associations of PNC with systolic blood pressure and pulse pressure. In contrast to the primary findings, an inter-quartile range increase in the PIR was positively associated with systolic blood pressure (β = 1.03; 95% CI = 0.00, 2.06 mmHg) and diastolic blood pressure (β = 1.01; 95% CI = 0.36, 1.66 mmHg), but not with pulse pressure or hsCRP. We observed that exposure to PNC was associated with increases in measures of CVD risk markers, especially among certain sub-populations. The exploratory PIR exposure metric should be

  2. Contributions of burner, pan, meat and salt to PM emission during grilling.

    PubMed

    Amouei Torkmahalleh, Mehdi; Ospanova, Saltanat; Baibatyrova, Aknur; Nurbay, Shynggys; Zhanakhmet, Gulaina; Shah, Dhawal

    2018-07-01

    Grilling ground beef meat was conducted in two locations at Nazarbayev University, Kazakhstan. The experiments were designed such that only particles from beef meat were isolated. A similar experimental protocol was applied at both locations. The average particle number and mass emission rates for grilling pure meat itself (excluding particles from pan and burner) were found to be 9.4 × 10 12 (SD = 7.2 × 10 12 particle min -1 and 7.6 × 10 (SD = 6.3 × 10) mg.min -1 , respectively. The PM emissions (number and mass) from the burner were found to be negligible compared to the pan and meat emissions. Ultrafine particle (UFP) concentrations from the heated pan itself were comparable to those of grilled meat. However, the particle mass concentrations from the pan itself were negligible. Approximately an hour of continuous heating resulted in zero emissions from the pan. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Factors influencing particle number concentrations, size distributions and modal parameters at a roof-level and roadside site in Leicester, UK.

    PubMed

    Agus, Emily L; Young, David T; Lingard, Justin J N; Smalley, Robert J; Tate, James E; Goodman, Paul S; Tomlin, Alison S

    2007-11-01

    Measurements of urban particle number concentrations and size distributions in the range 5-1000 nm were taken at elevated (roof-level) and roadside sampling sites on Narborough Road in Leicester, UK, along with simultaneous measurements of traffic, NO(x), CO and 1,3-butadiene concentrations and meteorological parameters. A fitting program was used to determine the characteristics of up to five modal groups present in the particle size distributions. All particle modal concentrations peaked during the morning and evening rush hours. Additional events associated with the smallest mode, that were not observed to be connected to primary emissions, were also present suggesting that this mode consisted of newly formed secondary particles. These events included peaks in concentration which coincided with peaks in solar radiation, and lower concentrations of the larger modes. Investigation into the relationships between traffic flow and occupancy indicated three flow regimes; free-flow, unstable and congested. During free-flow conditions, positive linear relationships existed between traffic flow and particle modal number concentrations. However, during unstable and congested periods, this relationship was shown to break-down. Similar trends were observed for concentrations of the gas phase pollutants NO(x), CO and 1,3-butadiene. Strong linear relationships existed between NO(x), CO, 1,3-butadiene concentrations, nucleation and Aitken mode concentrations at both sampling locations, indicating a local traffic related emission source. At the roadside, both nucleation and Aitken mode are best represented by a decreasing exponential function with wind speed, whereas at the roof-level this relationship only occurred for Aitken mode particles. The differing relationships at the two sampling locations are most likely due to a combination of meteorological factors and distance from the local emission source.

  4. [Adverse effects of ultrafine particles on the cardiovascular system and its mechanisms].

    PubMed

    Yi, Tie-ci; Li, Jian-ping

    2014-12-18

    Cardiovascular disease is one of the major threats to human. Air pollution, which , as it become a problem too serious to be ignored in China, is known to be an important risk factor for cardiovascular disease. Among all pollutants, ultrafine particles ( UFPs) , defined as particles with their diameter less than 0. 1 f.Lm, are a specific composition. They are very small in size, large in quantity and surface area, and most important, capable of passing through the air-blood barrier. These unique features of UFPs make them special in their impact on cardiovascular system. Nowadays, the influence of UFPs on the cardiovascular system has become a hot topic. On the one side, studies have shown that UFPs can cause inflammation and oxidative stress in the lung, and then induce systemic inflammation by releasing cytokine and reactive oxygen species into the circulation. On the other side, UFPs themselves can "spillout"into the circulation and interact with their targets. By this way, UFPs directly affect endothelial cells, myocardial cells and the autonomic nervous system, which ultimately result in increased cardiovascular events. We intend to make an overview about the recent progress about the influence of UFPs on human cardiovascular disease and the related mechanisms, and argue for more attention to this issue.

  5. Total deposition of ultrafine particles in the lungs of healthy men and women: experimental and theoretical results

    PubMed Central

    2016-01-01

    Background Inhaled ultrafine particles (UFP) may induce greater adverse respiratory effects than larger particles occurring in the ambient atmosphere. Due to this potential of UFP to act as triggers for diverse lung injuries medical as well as physical research has been increasingly focused on the exact deposition behavior of the particles in lungs of various probands. Main purpose of the present study was the presentation of experimental and theoretical data of total, regional, and local UFP deposition in the lungs of men and women. Methods Both experiments and theoretical simulations were carried out by using particle sizes of 0.04, 0.06, 0.08, and 0.10 µm [number median diameters (NMD)]. Inhalation of UFP took place by application of predefined tidal volumes (500, 750, and 1,000 mL) and respiratory flow rates (150, 250, 375, and 500 mL·s−1). For male subjects a functional residual capacity (FRC) of 3,911±892 mL was measured, whereas female probands had a FRC of 3,314±547 mL. Theoretical predictions were based on (I) a stochastic model of the tracheobronchial tree; (II) particle transport computations according to a random walk algorithm; and (III) empirical formulae for the description of UFP deposition. Results Total deposition fractions (TDF) are marked by a continuous diminution with increasing particle size. Whilst particles measuring 0.04 µm in size deposit in the respiratory tract by 40–70%, particles with a size of 0.10 µm exhibit deposition values ranging from 20% to 45%. Except for the largest particles studied here TDF of female probands are higher than those obtained for male probands. Differences between experimental and theoretical results are most significant for 0.10 µm particles, but never exceed 20%. Predictions of regional (extrathoracic, tracheobronchial, alveolar) UFP deposition show clearly that females tend to develop higher tracheobronchial and alveolar deposition fractions than males. This discrepancy is also confirmed by

  6. Changes in numbers of large ovarian follicles, plasma luteinizing hormone and estradiol-17beta concentrations and egg production figures in farmed ostriches throughout the year.

    PubMed

    Bronneberg, R G G; Stegeman, J A; Vernooij, J C M; Dieleman, S J; Decuypere, E; Bruggeman, V; Taverne, M A M

    2007-06-01

    In this study we described and analysed changes in the numbers of large ovarian follicles (diameter 6.1-9.0 cm) and in the plasma concentrations of luteinizing hormone (LH) and estradiol-17beta (E(2)beta) in relation to individual egg production figures of farmed ostriches (Struthio camelus spp.) throughout one year. Ultrasound scanning and blood sampling for plasma hormone analysis were performed in 9 hens on a monthly basis during the breeding season and in two periods of the non-breeding season. Our data demonstrated that: (1) large follicles were detected and LH concentrations were elevated already 1 month before first ovipositions of the egg production season took place; (2) E(2)beta concentrations increased as soon as the egg production season started; (3) numbers of large follicles, LH and E(2)beta concentrations were elevated during the entire egg production season; and that (4) numbers of large follicles, LH and E(2)beta concentrations decreased simultaneous with or following the last ovipositions of the egg production season. By comparing these parameters during the egg production season with their pre-and post-seasonal values, significant differences were found in the numbers of large follicles and E(2)beta concentrations between the pre-seasonal, seasonal and post-seasonal period; while LH concentrations were significantly different between the seasonal and post-seasonal period. In conclusion, our data demonstrate that changes in numbers of large follicles and in concentrations of LH and E(2)beta closely parallel individual egg production figures and provide some new cues that egg production in ostriches is confined to a marked reproductive season. Moreover, our data provide indications that mechanism, initiating, maintaining and terminating the egg production season in farmed breeding ostriches are quite similar to those already known for other seasonal breeding bird species.

  7. PEP Run Report for Integrated Test A, Caustic Leaching in UFP-VSL-T01A, Oxidative Leaching in UFP-VSL-T02A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guzman-Leong, Consuelo E.; Bredt, Ofelia P.; Burns, Carolyn A.

    2009-12-04

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed and constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.”(a) The PEP, located in the Process Engineering Laboratory-West (PDLW) located in Richland, Washington, is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes.more » The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.« less

  8. Postharvest Ultrasound-Assisted Freeze-Thaw Pretreatment Improves the Drying Efficiency, Physicochemical Properties, and Macamide Biosynthesis of Maca (Lepidium meyenii).

    PubMed

    Chen, Jin-Jin; Gong, Peng-Fei; Liu, Yi-Lan; Liu, Bo-Yan; Eggert, Dawn; Guo, Yuan-Heng; Zhao, Ming-Xia; Zhao, Qing-Sheng; Zhao, Bing

    2018-04-01

    A novel technique of ultrasound-assisted freeze-thaw pretreatment (UFP) was developed to improve the drying efficiency of maca and bioactive amide synthesis in maca. The optimal UFP conditions are ultrasonic processing 90 min at 30 °C with 6 freeze-thaw cycles. Samples with freeze-thaw pretreatment (FP), ultrasound pretreatment (UP), and UFP were prepared for further comparative study. A no pretreatment (NP) sample was included as a control. The results showed that UFP improved the drying efficiency of maca slices, showing the highest effective moisture diffusivity (1.75 × 10 -9 m 2 /s). This result was further supported by low-field nuclear magnetic resonance (LF-NMR) analysis and scanning electron microscopy (SEM). The rehydration capacity and protein content of maca slices were improved by UFP. More importantly, contents of bioactive macamides and their biosynthetic precursors were increased in 2.5- and 10-fold, respectively. In conclusion, UFP is an efficient technique to improve drying efficiency, physicochemical properties, and bioactive macamides of maca, which can be applied in the industrial manufacture of maca products. © 2018 Institute of Food Technologists®.

  9. International Airport Impacts to Air Quality: Size and Related Properties of Large Increases in Ultrafine Particle Number Concentrations.

    PubMed

    Hudda, N; Fruin, S A

    2016-04-05

    We measured particle size distributions and spatial patterns of particle number (PN) and particle surface area concentrations downwind from the Los Angeles International Airport (LAX) where large increases (over local background) in PN concentrations routinely extended 18 km downwind. These elevations were mostly comprised of ultrafine particles smaller than 40 nm. For a given downwind distance, the greatest increases in PN concentrations, along with the smallest mean sizes, were detected at locations under the landing jet trajectories. The smaller size of particles in the impacted area, as compared to the ambient urban aerosol, increased calculated lung deposition fractions to 0.7-0.8 from 0.5-0.7. A diffusion charging instrument (DiSCMini), that simulates alveolar lung deposition, measured a fivefold increase in alveolar-lung deposited surface area concentrations 2-3 km downwind from the airport (over local background), decreasing steadily to a twofold increase 18 km downwind. These ratios (elevated lung-deposited surface area over background) were lower than the corresponding ratios for elevated PN concentrations, which decreased from tenfold to twofold over the same distance, but the spatial patterns of elevated concentrations were similar. It appears that PN concentration can serve as a nonlinear proxy for lung deposited surface area downwind of major airports.

  10. The concentration of plasma metabolites varies throughout reproduction and affects offspring number in wild brown trout (Salmo trutta).

    PubMed

    Gauthey, Zoé; Freychet, Marine; Manicki, Aurélie; Herman, Alexandre; Lepais, Olivier; Panserat, Stéphane; Elosegi, Arturo; Tentelier, Cédric; Labonne, Jacques

    2015-06-01

    In wild populations, measuring energy invested in the reproduction and disentangling investment in gametes versus investment in reproductive behavior (such as intrasexual competition or intersexual preference) remain challenging. In this study, we investigated the energy expenditure in brown trout reproductive behavior by using two proxies: variation in weight and variation of plasma metabolites involved in energy production, over the course of reproductive season in a semi natural experimental river. We estimated overall reproductive success using genetic assignment at the end of the reproductive season. Results show that triglycerides and free fatty acid concentrations vary negatively during reproduction, while amino-acids and glucose concentrations remain stable. Decrease in triglyceride and free fatty acid concentrations during reproduction is not related to initial concentration levels or to weight variation. Both metabolite concentration variations and weight variations are correlated to the number of offspring produced, which could indicate that gametic and behavioral reproductive investments substantially contribute to reproductive success in wild brown trout. This study opens a path to further investigate variations in reproductive investment in wild populations. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Exposure to Ultrafine Particles from Ambient Air and Oxidative Stress–Induced DNA Damage

    PubMed Central

    Bräuner, Elvira Vaclavik; Forchhammer, Lykke; Møller, Peter; Simonsen, Jacob; Glasius, Marianne; Wåhlin, Peter; Raaschou-Nielsen, Ole; Loft, Steffen

    2007-01-01

    Background Particulate matter, especially ultrafine particles (UFPs), may cause health effects through generation of oxidative stress, with resulting damage to DNA and other macromolecules. Objective We investigated oxidative damage to DNA and related repair capacity in peripheral blood mononuclear cells (PBMCs) during controlled exposure to urban air particles with assignment of number concentration (NC) to four size modes with average diameters of 12, 23, 57, and 212 nm. Design Twenty-nine healthy adults participated in a randomized, two-factor cross-over study with or without biking exercise for 180 min and with exposure to particles (NC 6169-15362/cm3) or filtered air (NC 91-542/cm3) for 24 hr. Methods The levels of DNA strand breaks (SBs), oxidized purines as formamidopyrimidine DNA glycolase (FPG) sites, and activity of 7,8-dihydro-8-oxoguanine-DNA glycosylase (OGG1) in PBMCs were measured by the Comet assay. mRNA levels of OGG1, nucleoside diphosphate linked moiety X-type motif 1 (NUDT1), and heme oxygenase-1 (HO1) were determined by real-time reverse transcriptase–polymerase chain reaction. Results Exposure to UFPs for 6 and 24 hr significantly increased the levels of SBs and FPG sites, with a further insignificant increase after physical exercise. The OGG1 activity and expression of OGG1, NUDT1, and HO1 were unaltered. There was a significant dose–response relationship between NC and DNA damage, with the 57-nm mode as the major contributor to effects. Concomitant exposure to ozone, nitrogen oxides, and carbon monoxide had no influence. Conclusion Our results indicate that UFPs, especially the 57-nm soot fraction from vehicle emissions, causes systemic oxidative stress with damage to DNA and no apparent compensatory up-regulation of DNA repair within 24 hr. PMID:17687444

  12. A study of ambient fine particles at Tianjin International Airport, China.

    PubMed

    Ren, Jianlin; Liu, Junjie; Li, Fei; Cao, Xiaodong; Ren, Shengxiong; Xu, Bin; Zhu, Yifang

    2016-06-15

    The total count number concentration of particles from 10 to 1000nm, particle size distribution, and PM2.5 (aerodynamic diameter≤2.5μm) mass concentration were measured on a parking apron next to the runway at Tianjin International Airport in China. The data were collected 250, 270, 300, 350, and 400m from the runway. Wind direction and wind speed played important roles in determining the characteristics of the atmospheric particles. An inverted U-shaped relationship was observed between the measured particle number concentration and wind speed, with an average peak concentration of 2.2×10(5)particles/cm(3) at wind speeds of approximately 4-5m/s. The atmospheric particle number concentration was affected mainly by aircraft takeoffs and landings, and the PM2.5 mass concentration was affected mainly by the relative humidity (RH) of the atmosphere. Ultrafine particles (UFPs, diameter<100nm), with the highest number concentration at a particle size of approximately 16nm, dominated the measured particle size distributions. The calculated particle emission index values for aircraft takeoff and landing were nearly the same, with mean values of 7.5×10(15)particles/(kg fuel) and 7.6×10(15)particles/(kg fuel), respectively. The particle emission rate for one aircraft during takeoff is two orders of magnitude higher than for all gasoline-powered passenger vehicles in Tianjin combined. The particle number concentrations remained much higher than the background concentrations even beyond 400m from the runway. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Impact of smoking on in-vehicle fine particle exposure during driving

    NASA Astrophysics Data System (ADS)

    Sohn, Hongji; Lee, Kiyoung

    2010-09-01

    Indoor smoking ban in public places can reduce secondhand smoke (SHS) exposure. However, smoking in cars and homes has continued. The purpose of this study was to assess particulate matter less than 2.5 μm (PM 2.5) concentration in moving cars with different window opening conditions. The PM 2.5 level was measured by an aerosol spectrometer inside and outside moving cars simultaneously, along with ultrafine particle (UFP) number concentration, speed, temperature and humidity inside cars. Two sport utility vehicles were used. Three different ventilation conditions were evaluated by up to 20 repeated experiments. In the pre-smoking phase, average in-vehicle PM 2.5 concentrations were 16-17 μg m -3. Regardless of different window opening conditions, the PM 2.5 levels promptly increased when smoking occurred and decreased after cigarette was extinguished. Although only a single cigarette was smoked, the average PM 2.5 levels were 506-1307 μg m -3 with different window opening conditions. When smoking was ceased, the average PM 2.5 levels for 15 min were several times higher than the US National Ambient Air Quality Standard of 35 μg m -3. It took longer than 10 min to reach the level of the pre-smoking phase. Although UFP levels had a similar temporal profile of PM 2.5, the increased levels during the smoking phase were relatively small. This study demonstrated that the SHS exposure in cars with just a single cigarette being smoked could exceed the US EPA NAAQS under realistic window opening conditions. Therefore, the findings support the need for public education against smoking in cars and advocacy for a smoke-free car policy.

  14. Effects of cultivar, fruit number and reflected photosynthetically active radiation on Fragaria x ananassa productivity and fruit ellagic acid and ascorbic acid concentrations.

    PubMed

    Atkinson, C J; Dodds, P A A; Ford, Y Y; Le Mière, J; Taylor, J M; Blake, P S; Paul, N

    2006-03-01

    A number of strawberry varieties were surveyed for their total ellagic acid concentration, and attempts were made to determine if ellagic acid and ascorbic acid concentrations of two strawberry cultivars could be increased by polythene reflective mulches. After adjusting crop yields and cultivation using polythene mulches with two different PAR reflective capacities, field- and polytunnel-grown strawberries were analysed for ellagic acid and ascorbic acid concentrations by HPLC. Comparative measurements of yield and fruit quality were determined along with plant developmental changes. Ellagic acid concentration varied widely with strawberry cultivar (60-341 microg g(-1) frozen weight), as did the ratio of conjugated ellagic acid : free ellagic acid. Also, there was significant year-to-year variation in total ellagic acid concentration with some cultivars. Mulches with different reflective capacities impacted on strawberry production; highly reflective mulches significantly increased growth and yield, the latter due to increases in fruit size and number. Highly reflective mulches significantly increased total concentrations of ellagic acid and ascorbic acid relative to control in fruit of different cultivars. The potential of agronomic practices to enhance the concentration and amounts of these important dietary bioactive compounds is discussed.

  15. Developmental neurotoxicity of inhaled ambient ultrafine particle air pollution: Parallels with neuropathological and behavioral features of autism and other neurodevelopmental disorders.

    PubMed

    Allen, J L; Oberdorster, G; Morris-Schaffer, K; Wong, C; Klocke, C; Sobolewski, M; Conrad, K; Mayer-Proschel, M; Cory-Slechta, D A

    2017-03-01

    Accumulating evidence from both human and animal studies show that brain is a target of air pollution. Multiple epidemiological studies have now linked components of air pollution to diagnosis of autism spectrum disorder (ASD), a linkage with plausibility based on the shared mechanisms of inflammation. Additional plausibility appears to be provided by findings from our studies in mice of exposures from postnatal day (PND) 4-7 and 10-13 (human 3rd trimester equivalent), to concentrated ambient ultrafine (UFP) particles, considered the most reactive component of air pollution, at levels consistent with high traffic areas of major U.S. cities and thus highly relevant to human exposures. These exposures, occurring during a period of marked neuro- and gliogenesis, unexpectedly produced a pattern of developmental neurotoxicity notably similar to multiple hypothesized mechanistic underpinnings of ASD, including its greater impact in males. UFP exposures induced inflammation/microglial activation, reductions in size of the corpus callosum (CC) and associated hypomyelination, aberrant white matter development and/or structural integrity with ventriculomegaly (VM), elevated glutamate and excitatory/inhibitory imbalance, increased amygdala astrocytic activation, and repetitive and impulsive behaviors. Collectively, these findings suggest the human 3rd trimester equivalent as a period of potential vulnerability to neurodevelopmental toxicity to UFP, particularly in males, and point to the possibility that UFP air pollution exposure during periods of rapid neuro- and gliogenesis may be a risk factor not only for ASD, but also for other neurodevelopmental disorders that share features with ASD, such as schizophrenia, attention deficit disorder, and periventricular leukomalacia. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Developmental Neurotoxicity of Inhaled Ambient Ultrafine Particle Air Pollution: Parallels with Neuropathological and Behavioral Features of Autism and Other Neurodevelopmental Disorders

    PubMed Central

    Allen, J. L.; Oberdorster, G.; Morris-Schafer, K.; Wong, C.; Klocke, C.; Sobolewski, M.; Conrad, K.; Mayer-Proschel, M.; Cory-Slechta, D. A.

    2016-01-01

    Accumulating evidence from both human and animal studies show that brain is a target of air pollution. Multiple epidemiological studies have now linked components of air pollution to diagnosis of autism spectrum disorder (ASD), a linkage with plausibility based on the shared mechanisms of inflammation. Additional plausibility appears to be provided by findings from our studies in mice of exposures from postnatal day (PND) 4-7 and 10-13 (human 3rd trimester equivalent), to concentrated ambient ultrafine (UFP) particles, considered the most reactive component of air pollution, at levels consistent with high traffic areas of major U.S. cities and thus highly relevant to human exposures. These exposures, occurring during a period of marked neuro- and gliogenesis, unexpectedly produced a pattern of developmental neurotoxicity notably similar to multiple hypothesized mechanistic underpinnings of ASD, including its greater impact in males. UFP exposures induced inflammation/microglial activation, reductions in size of the corpus callosum (CC) and associated hypomyelination, aberrant white matter development and/or structural integrity with ventriculomegaly (VM), elevated glutamate and excitatory/inhibitory imbalance, increased amygdala astrocytic activation, and repetitive and impulsive behaviors. Collectively, these findings suggest the human 3rd trimester equivalent as a period of potential vulnerability to neurodevelopmental toxicity to UFP, particularly in males, and point to the possibility that UFP air pollution exposure during periods of rapid neuro- and gliogenesis may be a risk factor not only for ASD, but also for other neurodevelopmental disorders that share features with ASD, such as schizophrenia, attention deficit disorder, and periventricular leukomalacia. PMID:26721665

  17. Impacts of exposure to black carbon, elemental carbon, and ultrafine particles from indoor and outdoor sources on blood pressure in adults: A review of epidemiological evidence.

    PubMed

    Magalhaes, Sandra; Baumgartner, Jill; Weichenthal, Scott

    2018-02-01

    Ambient particulate air pollution is known to have detrimental effects on cardiovascular health but less is known about the specific effects of black carbon or elemental carbon (BC/EC) and ultrafine particles (UFP). We present a narrative review of the epidemiological evidence related to the impact of exposure to BC/EC and UFP on blood pressure in adults. We searched PubMed and EMBASE in September 2017, using a predefined search strategy. Abstracts were screened using predefined inclusion criteria. Data collection was completed using a standard data extraction form. We focused on main effect estimates for associations between short (≤7 days) and long-term exposures to BC/EC and UFP and systolic (SBP) and diastolic blood pressure (DBP). Effect estimates were rescaled to enable direct comparisons between studies. Thirty publications were included in the review: 19 studies examined outdoor exposure to BC/EC, 11 examined outdoor UFP, three studies examined indoor BC and one study examined indoor UFP. In general, existing evidence supports a positive association between BC/EC and blood pressure. Evidence for outdoor UFP exposures were less clear as effect estimates were small in magnitude and confidence intervals often included the null. Existing evidence supports a positive association between BC/EC and blood pressure in adults, whereas UFPs do not appear to have a meaningful impact on blood pressure. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Predicting decadal trends in cloud droplet number concentration using reanalysis and satellite data

    NASA Astrophysics Data System (ADS)

    McCoy, Daniel T.; Bender, Frida A.-M.; Grosvenor, Daniel P.; Mohrmann, Johannes K.; Hartmann, Dennis L.; Wood, Robert; Field, Paul R.

    2018-02-01

    Cloud droplet number concentration (CDNC) is the key state variable that moderates the relationship between aerosol and the radiative forcing arising from aerosol-cloud interactions. Uncertainty related to the effect of anthropogenic aerosol on cloud properties represents the largest uncertainty in total anthropogenic radiative forcing. Here we show that regionally averaged time series of the Moderate-Resolution Imaging Spectroradiometer (MODIS) observed CDNC of low, liquid-topped clouds is well predicted by the MERRA2 reanalysis near-surface sulfate mass concentration over decadal timescales. A multiple linear regression between MERRA2 reanalyses masses of sulfate (SO4), black carbon (BC), organic carbon (OC), sea salt (SS), and dust (DU) shows that CDNC across many different regimes can be reproduced by a simple power-law fit to near-surface SO4, with smaller contributions from BC, OC, SS, and DU. This confirms previous work using a less sophisticated retrieval of CDNC on monthly timescales. The analysis is supported by an examination of remotely sensed sulfur dioxide (SO2) over maritime volcanoes and the east coasts of North America and Asia, revealing that maritime CDNC responds to changes in SO2 as observed by the ozone monitoring instrument (OMI). This investigation of aerosol reanalysis and top-down remote-sensing observations reveals that emission controls in Asia and North America have decreased CDNC in their maritime outflow on a decadal timescale.

  19. Modeling the relative contributions of secondary ice formation processes to ice crystal number concentrations within mixed-phase clouds

    NASA Astrophysics Data System (ADS)

    Sullivan, Sylvia; Hoose, Corinna; Nenes, Athanasios

    2016-04-01

    Measurements of in-cloud ice crystal number concentrations can be three or four orders of magnitude greater than the in-cloud ice nuclei number concentrations. This discrepancy can be explained by various secondary ice formation processes, which occur after initial ice nucleation, but the relative importance of these processes, and even the exact physics of each, is still unclear. A simple bin microphysics model (2IM) is constructed to investigate these knowledge gaps. 2IM extends the time-lag collision parameterization of Yano and Phillips, 2011 to include rime splintering, ice-ice aggregation, and droplet shattering and to incorporate the aspect ratio evolution as in Jensen and Harrington, 2015. The relative contribution of the secondary processes under various conditions are shown. In particular, temperature-dependent efficiencies are adjusted for ice-ice aggregation versus collision around -15°C, when rime splintering is no longer active, and the effect of aspect ratio on the process weighting is explored. The resulting simulations are intended to guide secondary ice formation parameterizations in larger-scale mixed-phase cloud schemes.

  20. Transcriptional profiling of human bronchial epithelial cell BEAS-2B exposed to diesel and biomass ultrafine particles.

    PubMed

    Grilli, Andrea; Bengalli, Rossella; Longhin, Eleonora; Capasso, Laura; Proverbio, Maria Carla; Forcato, Mattia; Bicciato, Silvio; Gualtieri, Maurizio; Battaglia, Cristina; Camatini, Marina

    2018-04-27

    Emissions from diesel vehicles and biomass burning are the principal sources of primary ultrafine particles (UFP). The exposure to UFP has been associated to cardiovascular and pulmonary diseases, including lung cancer. Although many aspects of the toxicology of ambient particulate matter (PM) have been unraveled, the molecular mechanisms activated in human cells by the exposure to UFP are still poorly understood. Here, we present an RNA-seq time-course experiment (five time point after single dose exposure) used to investigate the differential and temporal changes induced in the gene expression of human bronchial epithelial cells (BEAS-2B) by the exposure to UFP generated from diesel and biomass combustion. A combination of different bioinformatics tools (EdgeR, next-maSigPro and reactome FI app-Cytoscape and prioritization strategies) facilitated the analyses the temporal transcriptional pattern, functional gene set enrichment and gene networks related to cellular response to UFP particles. The bioinformatics analysis of transcriptional data reveals that the two different UFP induce, since the earliest time points, different transcriptional dynamics resulting in the activation of specific genes. The functional enrichment of differentially expressed genes indicates that the exposure to diesel UFP induces the activation of genes involved in TNFα signaling via NF-kB and inflammatory response, and hypoxia. Conversely, the exposure to ultrafine particles from biomass determines less distinct modifications of the gene expression profiles. Diesel UFP exposure induces the secretion of biomarkers associated to inflammation (CCXL2, EPGN, GREM1, IL1A, IL1B, IL6, IL24, EREG, VEGF) and transcription factors (as NFE2L2, MAFF, HES1, FOSL1, TGIF1) relevant for cardiovascular and lung disease. By means of network reconstruction, four genes (STAT3, HIF1a, NFKB1, KRAS) have emerged as major regulators of transcriptional response of bronchial epithelial cells exposed to diesel

  1. Maternal and fetal outcomes after uterine fundal pressure in spontaneous and assisted vaginal deliveries.

    PubMed

    Furrer, Romana; Schäffer, Leonhard; Kimmich, Nina; Zimmermann, Roland; Haslinger, Christian

    2016-10-01

    This study aimed to evaluate maternal and fetal outcomes after uterine fundal pressure (UFP) in spontaneous and assisted vaginal deliveries. In a retrospective cohort study, 9743 singleton term deliveries with cephalic presentation were analyzed from 2004 to 2013. Spontaneous and assisted vaginal deliveries were analyzed separately with and without the application of UFP. Odds ratios were adjusted in a multivariate logistic regression analysis. Prevalence of UFP was 8.9% in spontaneous and 12.1% in assisted vaginal deliveries. UFP was associated with a higher incidence of shoulder dystocia in both spontaneous (adjusted odds ratio [adj. OR] 2.44, confidence interval [CI] 95% 1.23-4.84) and assisted vaginal deliveries (adj. OR 6.88 CI 95% 3.50-13.53). Fetal acidosis (arterial umbilical pH<7.2) was seen more often after the application of UFP in spontaneous vaginal deliveries (adj. OR 3.18, CI 95% 2.64-3.82) and assisted vaginal deliveries (adj. OR 1.59 CI 95% 1.17-2.16). The incidence of 5'-Apgar<7 (adj. OR 2.19 CI 95% 1.04-4.6) and 10'-Apgar<7 (adj. OR 3.04 CI 95% 1.17-7.88) was also increased after the application of UFP in spontaneous deliveries. A higher incidence of anal sphincter tears (AST) (adj. OR 46.25 CI 95% 11.78-181.6) in the UFP group of spontaneous deliveries was observed. UFP is associated with increased occurrence of shoulder dystocia and fetal acidosis. In spontaneous deliveries, the risk for lower Apgar scores after 5 and 10 min is increased, as well as the risk for AST.

  2. Association of Long-Term Near-Highway Exposure to Ultrafine Particles with Cardiovascular Diseases, Diabetes and Hypertension.

    PubMed

    Li, Yu; Lane, Kevin J; Corlin, Laura; Patton, Allison P; Durant, John L; Thanikachalam, Mohan; Woodin, Mark; Wang, Molin; Brugge, Doug

    2017-04-26

    Ultrafine particle (UFP) concentrations are elevated near busy roadways, however, their effects on prevalence of cardiovascular diseases, diabetes, and hypertension are not well understood. To investigate these associations, data on demographics, diseases, medication use, and time of activities were collected by in-home surveys for 704 participants in three pairs of near-highway and urban background neighborhoods in and near Boston (MA, USA). Body mass index (BMI) was measured for a subset of 435 participants. Particle number concentration (PNC, a measure of UFP) was collected by mobile monitoring in each area. Intra-neighborhood spatial-temporal regression models (approximately 20 m resolution) were used to estimate hourly ambient PNC at the residences of participants. We used participant time activity information to adjust annual average residential PNC values and assign individualized time activity adjusted annual average PNC exposures (TAA-PNC). Using multivariate logistic regression models, we found an odds ratio (OR) of 1.35 (95% CI: 0.83, 2.22) of TAA-PNC with stroke and ischemic heart diseases (S/IHD), an OR of 1.14 (95% CI: 0.81, 1.62) with hypertension, and an OR of 0.71 (95% CI: 0.46, 1.10) for diabetes. A subset analysis controlling for BMI produced slightly stronger associations for S/IHD (OR = 1.61, 95% CI: 0.88, 2.92) and hypertension (OR = 1.28, 95% CI: 0.81, 2.02), and no association with diabetes (OR = 1.09, 95% CI = 0.61, 1.96). Further research is needed with larger sample sizes and longitudinal follow-up.

  3. Accumulation-mode aerosol number concentrations in the Arctic during the ARCTAS aircraft campaign: Long-range transport of polluted and clean air from the Asian continent

    NASA Astrophysics Data System (ADS)

    Matsui, H.; Kondo, Y.; Moteki, N.; Takegawa, N.; Sahu, L. K.; Koike, M.; Zhao, Y.; Fuelberg, H. E.; Sessions, W. R.; Diskin, G.; Anderson, B. E.; Blake, D. R.; Wisthaler, A.; Cubison, M. J.; Jimenez, J. L.

    2011-10-01

    We evaluate the impact of transport from midlatitudes on aerosol number concentrations in the accumulation mode (light-scattering particles (LSP) with diameters >180 nm) in the Arctic during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) campaign. We focus on transport from the Asian continent. We find marked contrasts in the number concentration (NLSP), transport efficiency (TEN_LSP, the fraction transported from sources to the Arctic), size distribution, and the chemical composition of aerosols between air parcels from anthropogenic sources in East Asia (Asian AN) and biomass burning sources in Russia and Kazakhstan (Russian BB). Asian AN air had lower NLSP and TEN_LSP (25 cm-3 and 18% in spring and 6.2 cm-3 and 3.0% in summer) than Russian BB air (280 cm-3 and 97% in spring and 36 cm-3 and 7.6% in summer) due to more efficient wet scavenging during transport from East Asia. Russian BB in this spring is the most important source of accumulation-mode aerosols over the Arctic, and BB emissions are found to be the primary source of aerosols within all the data in spring during ARCTAS. On the other hand, the contribution of Asian AN transport had a negligible effect on the accumulation-mode aerosol number concentration in the Arctic during ARCTAS. Compared with background air, NLSP was 2.3-4.7 times greater for Russian BB air but 2.4-2.6 times less for Asian AN air in both spring and summer. This result shows that the transport of Asian AN air decreases aerosol number concentrations in the Arctic, despite the large emissions of aerosols in East Asia. The very low aerosol number concentrations in Asian AN air were caused by wet removal during vertical transport in association with warm conveyor belts (WCBs). Therefore, this cleansing effect will be prominent for air transported via WCBs from other midlatitude regions and seasons. The inflow of clean midlatitude air can potentially have an important impact on

  4. Airborne measurement of submicron aerosol number concentration and CCN activity in and around the Korean Peninsula and their comparison to ground measurement in Seoul

    NASA Astrophysics Data System (ADS)

    Park, M.; Kim, N.; Yum, S. S.

    2016-12-01

    Aerosols exert impact not only on human health and visibility but also on climate change directly by scattering or absorbing solar radiation and indirectly by acting as cloud condensation nuclei (CCN) and thus altering cloud radiative and microphysical properties. Aerosol indirect effects on climate has been known to have large uncertainty because of insufficient measurement data on aerosol and CCN activity distribution. Submicron aerosol number concentration (NCN, TSI CPC) and CCN number concentration (NCCN, DMT CCNC) were measured on board the NASA DC-8 research aircraft and at a ground site at Olympic Park in Seoul from May 2nd to June 10th, 2016. CCNC on the airborne platform was operated with the fixed internal supersaturation of 0.6% and CCNC at the ground site was operated with the five different supersaturations (0.2%, 0.4%, 0.6%, 0.8%, and 1.0%). The NASA DC-8 conducted 20 research flights (about 150 hours) in and around the Korean Peninsula and the ground measurement at Olympic Park was continuously made during the measurement period. Both airborne and ground measurements showed spatially and temporally varied aerosol number concentration and CCN activity. Aerosol number concentration in the boundary layer measured on airborne platform was highly affected by pollution sources on the ground. The average diurnal distribution of ground aerosol number concentration showed distinct peaks are located at about 0800, 1500, and 2000. The middle peak indicates that new particle formation events frequently occurred during the measurement period. CCN activation ratio at 0.6% supersaturation (NCCN/NCN) of the airborne measurement ranged from 0.1 to 0.9, indicating that aerosol properties in and around the Korean Peninsula varied so much (e. g. size, hygroscopicity). Comprehensive analysis results will be shown at the conference.

  5. Global impact of mineral dust on cloud droplet number concentration

    NASA Astrophysics Data System (ADS)

    Karydis, Vlassis A.; Tsimpidi, Alexandra P.; Bacer, Sara; Pozzer, Andrea; Nenes, Athanasios; Lelieveld, Jos

    2017-05-01

    The importance of wind-blown mineral dust for cloud droplet formation is studied by considering (i) the adsorption of water on the surface of insoluble particles, (ii) particle coating by soluble material (atmospheric aging) which augments cloud condensation nuclei (CCN) activity, and (iii) the effect of dust on inorganic aerosol concentrations through thermodynamic interactions with mineral cations. The ECHAM5/MESSy Atmospheric Chemistry (EMAC) model is used to simulate the composition of global atmospheric aerosol, while the ISORROPIA-II thermodynamic equilibrium model treats the interactions of K+-Ca2+-Mg2+-NH4+-Na+-SO42--NO3--Cl--H2O aerosol with gas-phase inorganic constituents. Dust is considered a mixture of inert material with reactive minerals and its emissions are calculated online by taking into account the soil particle size distribution and chemical composition of different deserts worldwide. The impact of dust on droplet formation is treated through the unified dust activation parameterization that considers the inherent hydrophilicity from adsorption and acquired hygroscopicity from soluble salts during aging. Our simulations suggest that the presence of dust increases cloud droplet number concentration (CDNC) over major deserts (e.g., up to 20 % over the Sahara and the Taklimakan desert) and decreases CDNC over polluted areas (e.g., up to 10 % over southern Europe and 20 % over northeastern Asia). This leads to a global net decrease in CDNC by 11 %. The adsorption activation of insoluble aerosols and the mineral dust chemistry are shown to be equally important for the cloud droplet formation over the main deserts; for example, these effects increase CDNC by 20 % over the Sahara. Remote from deserts the application of adsorption theory is critically important since the increased water uptake by the large aged dust particles (i.e., due to the added hydrophilicity by the soluble coating) reduce the maximum supersaturation and thus cloud droplet

  6. Fingerprint of Lung Fluid Ultrafine Particles, a Novel Marker of Acute Lung Inflammation.

    PubMed

    Bar-Shai, Amir; Alcalay, Yifat; Sagiv, Adi; Rotem, Michal; Feigelson, Sara W; Alon, Ronen; Fireman, Elizabeth

    2015-01-01

    Acute lung inflammation can be monitored by various biochemical readouts of bronchoalveolar lavage fluid (BALF). To analyze the BALF content of ultrafine particles (UFP; <100 nm) as an inflammatory biomarker in early diagnosis of acute and chronic lung diseases. Mice were exposed to different stress conditions and inflammatory insults (acute lipopolysaccharide inhalation, tobacco smoke and lethal dose of total body irradiation, i.e. 950 rad). After centrifugation, the cellular pellet was assessed while cytokines and ultrafine particles were measured in the soluble fraction of the BALF. A characteristic UFP distribution with a D50 (i.e. the dimension of the 50th UFP percentile) was shared by all tested mouse strains in the BALF of resting lungs. All tested inflammatory insults similarly shifted this size distribution, resulting in a unique UFP fingerprint with an averaged D50 of 58.6 nm, compared with the mean UFP D50 of 23.7 nm for resting BALF (p < 0.0001). This UFP profile was highly reproducible and independent of the intensity or duration of the inflammatory trigger. It returned to baseline after resolution of the inflammation. Neither total body irradiation nor induction of acute cough induced this fingerprint. The UFP fingerprint in the BALF of resting and inflamed lungs can serve as a binary biomarker of healthy and acutely inflamed lungs. This marker can be used as a novel readout for the onset of inflammatory lung diseases and for complete lung recovery from different insults.

  7. Size resolved ultrafine particles emission model--a continues size distribution approach.

    PubMed

    Nikolova, Irina; Janssen, Stijn; Vrancken, Karl; Vos, Peter; Mishra, Vinit; Berghmans, Patrick

    2011-08-15

    A new parameterization for size resolved ultrafine particles (UFP) traffic emissions is proposed based on the results of PARTICULATES project (Samaras et al., 2005). It includes the emission factors from the Emission Inventory Guidebook (2006) (total number of particles, #/km/veh), the shape of the corresponding particle size distribution given in PARTICULATES and data for the traffic activity. The output of the model UFPEM (UltraFine Particle Emission Model) is a sum of continuous distributions of ultrafine particles emissions per vehicle type (passenger cars and heavy duty vehicles), fuel (petrol and diesel) and average speed representative for urban, rural and highway driving. The results from the parameterization are compared with measured total number of ultrafine particles and size distributions in a tunnel in Antwerp (Belgium). The measured UFP concentration over the entire campaign shows a close relation to the traffic activity. The modelled concentration is found to be lower than the measured in the campaign. The average emission factor from the measurement is 4.29E+14 #/km/veh whereas the calculated is around 30% lower. A comparison of emission factors with literature is done as well and in overall a good agreement is found. For the size distributions it is found that the measured distributions consist of three modes--Nucleation, Aitken and accumulation and most of the ultrafine particles belong to the Nucleation and the Aitken modes. The modelled Aitken mode (peak around 0.04-0.05 μm) is found in a good agreement both as amplitude of the peak and the number of particles whereas the modelled Nucleation mode is shifted to smaller diameters and the peak is much lower that the observed. Time scale analysis shows that at 300 m in the tunnel coagulation and deposition are slow and therefore neglected. The UFPEM emission model can be used as a source term in dispersion models. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Comparison of sources of submicron particle number concentrations measured at two sites in Rochester, NY.

    PubMed

    Kasumba, John; Hopke, Philip K; Chalupa, David C; Utell, Mark J

    2009-09-01

    Sources contributing to the submicron particles (100-470 nm) measured between January 2002 and December 2007 at two different New York State Department of Environmental Conservation (NYS DEC) sites in Rochester, NY were identified and apportioned using a bilinear receptor model, positive matrix factorization (PMF). Measurements of aerosol size distributions and number concentrations for particles in the size range of 10-500 nm have been made since December 2001 to date in Rochester. The measurements are being made using a scanning mobility particle sizer (SMPS) consisting of a DMA and a CPC (TSI models 3071 and 3010, respectively). From December 2001 to March 2004, particle measurements were made at the NYS DEC site in downtown Rochester, but it was moved to the eastside of Rochester in May 2004. Each measurement period was divided into three seasons i.e., winter (December, January, and February), summer (June, July, and August), and the transitional periods (March, April, May, September, October, and November) so as to avoid experimental uncertainty resulting from too large season-to-season variability in ambient temperature and solar photon intensity that would lead to unstable/non-stationary size distributions. Therefore, the seasons were analyzed independently for possible sources. Ten sources were identified at both sites and these include traffic, nucleation, residential/commercial heating, industrial emissions, secondary nitrate, ozone- rich secondary aerosol, secondary sulfate, regionally transported aerosol, and a mixed source of nucleation and traffic. These results show that the measured total outdoor particle number concentrations in Rochester generally vary with similar temporal patterns, suggesting that the central monitoring site data can be used to estimate outdoor exposure in other parts of the city.

  9. Composition of Metallic Elements and Size Distribution of Fine and Ultrafine Particles in a Steelmaking Factory.

    PubMed

    Marcias, Gabriele; Fostinelli, Jacopo; Catalani, Simona; Uras, Michele; Sanna, Andrea Maurizio; Avataneo, Giuseppe; De Palma, Giuseppe; Fabbri, Daniele; Paganelli, Matteo; Lecca, Luigi Isaia; Buonanno, Giorgio; Campagna, Marcello

    2018-06-07

    The characteristics of aerosol, in particular particle size and chemical composition, can have an impact on human health. Particle size distribution and chemical composition is a necessary parameter in occupational exposure assessment conducted in order to understand possible health effects. The aim of this study was to characterize workplace airborne particulate matter in a metallurgical setting by synergistically using two different approaches; Methodology: Analysis of inhalable fraction concentrations through traditional sampling equipment and ultrafine particles (UFP) concentrations and size distribution was conducted by an Electric Low-Pressure Impactor (ELPI+™). The determination of metallic elements (ME) in particles was carried out by inductively coupled plasma mass spectrometry; Results: Inhalable fraction and ME concentrations were below the limits set by Italian legislation and the American Conference of Governmental Industrial Hygienists (ACGIH, 2017). The median of UFP was between 4.00 × 10⁴ and 2.92 × 10⁵ particles/cm³. ME concentrations determined in the particles collected by ELPI show differences in size range distribution; Conclusions: The adopted synergistic approach enabled a qualitative and quantitative assessment of the particles in steelmaking factories. The results could lead to a better knowledge of occupational exposure characterization, in turn affording a better understanding of occupational health issues due to metal fumes exposure.

  10. Fine and ultrafine particle doses in the respiratory tract from digital printing operations.

    PubMed

    Voliotis, Aristeidis; Karali, Irene; Kouras, Athanasios; Samara, Constantini

    2017-01-01

    In this study, we report for the first time particle number doses in different parts of the human respiratory tract and real-time deposition rates for particles in the 10 nm to 10 μm size range emitted by digital printing operations. Particle number concentrations (PNCs) and size distribution were measured in a typical small-sized printing house using a NanoScan scanning mobility particle sizer and an optical particle sizer. Particle doses in human lung were estimated applying a multiple-path particle dosimetry model under two different breathing scenarios. PNC was dominated by the ultrafine particle fractions (UFPs, i.e., particles smaller than 100 nm) exhibiting almost nine times higher levels in comparison to the background values. The average deposition rate fοr each scenario in the whole lung was estimated at 2.0 and 2.9 × 10 7 particles min -1 , while the respective highest particle dose in the tracheobronchial tree (2.0 and 2.9 × 10 9 particles) was found for diameter of 50 nm. The majority of particles appeared to deposit in the acinar region and most of them were in the UFP size range. For both scenarios, the maximum deposition density (9.5 × 10 7 and 1.5 × 10 8 particles cm -2 ) was observed at the lobar bronchi. Overall, the differences in the estimated particle doses between the two scenarios were 30-40% for both size ranges.

  11. Surface area-dependence of gas-particle interactions influences pulmonary and neuroinflammatory outcomes.

    PubMed

    Tyler, Christina R; Zychowski, Katherine E; Sanchez, Bethany N; Rivero, Valeria; Lucas, Selita; Herbert, Guy; Liu, June; Irshad, Hammad; McDonald, Jacob D; Bleske, Barry E; Campen, Matthew J

    2016-12-01

    particles is an important determinant of toxic responses. As such, freshly generated UFP, in the presence of combustion-derived gas phase pollutants, may be a greater health hazard than would be predicted from PM concentration, alone, lending support for epidemiological findings of adverse neurological outcomes associated with roadway proximity.

  12. Short-term exposure to PM 10, PM 2.5, ultrafine particles and CO 2 for passengers at an intercity bus terminal

    NASA Astrophysics Data System (ADS)

    Cheng, Yu-Hsiang; Chang, Hsiao-Peng; Hsieh, Cheng-Ju

    2011-04-01

    The Taipei Bus Station is the main transportation hub for over 50 bus routes to eastern, central, and southern Taiwan. Daily traffic volume at this station is about 2500 vehicles, serving over 45,000 passengers daily. The station is a massive 24-story building housing a bus terminal, a business hotel, a shopping mall, several cinemas, offices, private residential suites, and over 900 parking spaces. However, air quality inside this bus terminal is a concern as over 2500 buses are scheduled to run daily. This study investigates the PM 10, PM 2.5, UFP and CO 2 levels inside and outside the bus terminal. All measurements were taken between February and April 2010. Measurement results show that coarse PM inside the bus terminal was resuspended by the movement of large numbers of passengers. The fine and ultrafine PM in the station concourse were from outside vehicles. Moreover, fine and ultrafine PM at waiting areas were exhausted directly from buses in the building. The CO 2 levels at waiting areas were likely elevated by bus exhaust and passengers exhaling. The PM 10, PM 2.5 and CO 2 levels at the bus terminal were lower than Taiwan's EPA suggested standards for indoor air quality. However, UFP levels at the bus terminal were significantly higher than those in the urban background by about 10 times. Therefore, the effects of UFPs on the health of passengers and workers must be addressed at this bus terminal since the levels of UFPs are higher than >1.0 × 10 5 particles cm -3.

  13. Global statistics of liquid water content and effective number concentration of water clouds over ocean derived from combined CALIPSO and MODIS measurements

    NASA Astrophysics Data System (ADS)

    Hu, Y.; Vaughan, M.; McClain, C.; Behrenfeld, M.; Maring, H.; Anderson, D.; Sun-Mack, S.; Flittner, D.; Huang, J.; Wielicki, B.; Minnis, P.; Weimer, C.; Trepte, C.; Kuehn, R.

    2007-06-01

    This study presents an empirical relation that links the volume extinction coefficients of water clouds, the layer integrated depolarization ratios measured by lidar, and the effective radii of water clouds derived from collocated passive sensor observations. Based on Monte Carlo simulations of CALIPSO lidar observations, this method combines the cloud effective radius reported by MODIS with the lidar depolarization ratios measured by CALIPSO to estimate both the liquid water content and the effective number concentration of water clouds. The method is applied to collocated CALIPSO and MODIS measurements obtained during July and October of 2006, and January 2007. Global statistics of the cloud liquid water content and effective number concentration are presented.

  14. Seasonal and spatial trends in particle number concentrations and size distributions at the children's health study sites in Southern California.

    PubMed

    Singh, Manisha; Phuleria, Harish C; Bowers, Kenneth; Sioutas, Constantinos

    2006-01-01

    Continuous measurements of particle number (PN), particle mass (PM(10)) and gaseous copollutants (NO(x), CO and O3) were obtained at eight sites (urban, suburban and remote) in Southern California during years 2002 and 2003 in support of University of Southern California Children's Health Study. We report the spatial and temporal variation of PNs and size distributions within these sites. Higher average total PN concentrations are found in winter (November to February), compared to summer (July to September) and spring (March to June) in all urban sites. Contribution of local vehicular emissions is most evident in cooler months, whereas effects of long-range transport of particles are enhanced during warmer periods. The particle size profile is most represented by a combination of the spatial effects, for example, sources, atmospheric processes and meteorological conditions prevalent at each location. Afternoon periods in the warmer months are characterized by elevated number concentrations that either coincide or follow a peak in ozone concentrations, suggesting the formation of new particles by photochemistry. Results show no meaningful correlation between PN and mass, indicating that mass based standards may not be effective in controlling ultrafine particles. The study of the impact of the Union worker's strike at port of Long Beach in October 2002 revealed statistically significant increase in PN concentrations in the 60-200 nm range (P<0.001), which are indicative of contributions of emissions from the idling ships at the port.

  15. Vertical distribution of aerosol number concentration in the troposphere over Siberia derived from airborne in-situ measurements

    NASA Astrophysics Data System (ADS)

    Arshinov, Mikhail Yu.; Belan, Boris D.; Paris, Jean-Daniel; Machida, Toshinobu; Kozlov, Alexandr; Malyskin, Sergei; Simonenkov, Denis; Davydov, Denis; Fofonov, Alexandr

    2016-04-01

    Knowledge of the vertical distribution of aerosols particles is very important when estimating aerosol radiative effects. To date there are a lot of research programs aimed to study aerosol vertical distribution, but only a few ones exist in such insufficiently explored region as Siberia. Monthly research flights and several extensive airborne campaigns carried out in recent years in Siberian troposphere allowed the vertical distribution of aerosol number concentration to be summarized. In-situ aerosol measurements were performed in a wide range of particle sizes by means of improved version of the Novosibirsk-type diffusional particle sizer and GRIMM aerosol spectrometer Model 1.109. The data on aerosol vertical distribution enabled input parameters for the empirical equation of Jaenicke (1993) to be derived for Siberian troposphere up to 7 km. Vertical distributions of aerosol number concentration in different size ranges averaged for the main seasons of the year will be presented. This work was supported by Interdisciplinary integration projects of the Siberian Branch of the Russian Academy of Science No. 35, No. 70 and No. 131; the Branch of Geology, Geophysics and Mining Sciences of RAS (Program No. 5); and Russian Foundation for Basic Research (grant No. 14-05-00526). Jaenicke R. Tropospheric aerosols, in Aerosol-Cloud-Climate Interactions, edited by P.V. Hobs. -Academic Press, San Diego, CA, 1993.- P. 1-31.

  16. [Computer modeling the dependences of the membrane potential for polymeric membrane separated non-homogeneous electrolyte solutions on concentration Rayleigh number].

    PubMed

    Slezak, Izabella H; Jasik-Slezak, Jolanta; Bilewicz-Wyrozumska, Teresa; Slezak, Andrzej

    2006-01-01

    On the basis of model equation describing the membrane potential delta psi(s) on concentration Rayleigh number (R(C)), mechanical pressure difference (deltaP), concentration polarization coefficient (zeta s) and ratio concentration of solutions separated by membrane (Ch/Cl), the characteristics delta psi(s) = f(Rc)(delta P, zeta s, Ch/Cl) for steady values of zeta s, R(C) and Ch/Cl in single-membrane system were calculated. In this system neutral and isotropic polymeric membrane oriented in horizontal plane, the non-homogeneous binary electrolytic solutions of various concentrations were separated. Nonhomogeneity of solutions is results from creations of the concentration boundary layers on both sides of the membrane. Calculations were made for the case where on a one side of the membrane aqueous solution of NaCl at steady concentration 10(-3) mol x l(-1) (Cl) was placed and on the other aqueous solutions of NaCl at concentrations from 10(-3) mol x l(-1) to 2 x 10(-2) mol x l(-1) (Ch). Their densities were greater than NaCl solution's at 10(-3) mol x l(-1). It was shown that membrane potential depends on hydrodynamic state of a complex concentration boundary layer-membrane-concentration boundary layer, what is controlled by deltaP, Ch/Cl, Rc and Zeta(s).

  17. Characteristics of Ambient Black Carbon Mass and Size-Resolved Particle Number Concentrations during Corn Straw Open-Field Burning Episode Observations at a Rural Site in Southern Taiwan.

    PubMed

    Cheng, Yu-Hsiang; Yang, Li-Sing

    2016-07-08

    Information on the effect of open-field burning of agricultural residues on ambient black carbon (BC) mass and size-resolved particle number concentrations is scarce. In this study, to understand the effect of such open-field burning on short-term air quality, real-time variations of the BC mass and size-resolved particle number concentrations were monitored before and during a corn straw open-field burning episode at a rural site. Correlations between the BC mass and size-resolved particle number concentrations during the episode were investigated. Moreover, the particle number size distribution and absorption Ångström exponent were determined for obtaining the characteristics of aerosol emissions from the corn straw open-field burning. The results can be used to address public health concerns and as a reference for managing similar episodes of open-field burning of agricultural residues.

  18. Characterization and source apportionment of particle number concentration at a semi-urban tropical environment.

    PubMed

    Khan, Md Firoz; Latif, Mohd Talib; Amil, Norhaniza; Juneng, Liew; Mohamad, Noorlin; Nadzir, Mohd Shahrul Mohd; Hoque, Hossain Mohammed Syedul

    2015-09-01

    Principal component analysis (PCA) and correlation have been used to study the variability of particle mass and particle number concentrations (PNC) in a tropical semi-urban environment. PNC and mass concentration (diameter in the range of 0.25->32.0 μm) have been measured from 1 February to 26 February 2013 using an in situ Grimm aerosol sampler. We found that the 24-h average total suspended particulates (TSP), particulate matter ≤10 μm (PM10), particulate matter ≤2.5 μm (PM2.5) and particulate matter ≤1 μm (PM1) were 14.37 ± 4.43, 14.11 ± 4.39, 12.53 ± 4.13 and 10.53 ± 3.98 μg m(-3), respectively. PNC in the accumulation mode (<500 nm) was the most abundant (at about 99 %). Five principal components (PCs) resulted from the PCA analysis where PC1 (43.8 % variance) predominates with PNC in the fine and sub-microme tre range. PC2, PC3, PC4 and PC5 explain 16.5, 12.4, 6.0 and 5.6 % of the variance to address the coarse, coarser, accumulation and giant fraction of PNC, respectively. Our particle distribution results show good agreement with the moderate resolution imaging spectroradiometer (MODIS) distribution.

  19. Retroperitoneal laparoscopy management for ureteral fibroepithelial polyps causing hydronephrosis in children: a report of five cases.

    PubMed

    Dai, L N; Chen, C D; Lin, X K; Wang, Y B; Xia, L G; Liu, P; Chen, X M; Li, Z R

    2015-10-01

    Hydronephrosis is a common disease in children and may be caused by ureteral fibroepithelial polyps (UFP). Ureteral fibroepithelial polyps are rare in children and are difficult to precisely diagnose before surgery. Surgical treatment for symptomatic UFP is recommended. At the present institution, retroperitoneal laparoscopy has been used to treat five boys with UFP since 2006. To highlight the significance of UFP as an etiological factor of hydronephrosis in children and evaluate the applicative value of retroperitoneal laparoscopy in the treatment of children with UFP. Between 2006 and 2013 five boys underwent retroperitoneal laparoscopy at the present institution. They were identified with UFP by review of the clinical database. Detailed data were collected, including: radiographic studies, gross anatomical pathology, and pathology and radiology reports. All boys had been followed up at least every 6 months. All of the boys were aged between 7 and 16 years (mean 9.8 years). The main symptoms were flank pain (all five) and hematuria (three). Radiographic examination showed that all of the boys presented with incomplete ureteral obstruction and hydronephrosis. The ureteral fibroepithelial polyps were located near the left UPJ or the left proximal ureter. All of the boys had the UFP removed: three underwent retroperitoneal laparoscopic dismembered Anderson-Hynes pyeloplasty and polypectomy, and two had retroperitoneal laparoscopic ureteral anastomosis. These polyps were all on the left side and between 15 and 35 mm in length (mean 22 mm) (Figure). All of the boys recovered well and were discharged from hospital. The postoperative histological report confirmed that the specimens were UFP. Hydronephrosis was periodically assessed by ultrasonography (using the same method as pre-surgical ultrasonography) after surgery. Mean follow-up was 33 months (range 6-58 months) and no complications were found afterwards. Ureteral fibroepithelial polyps are rare but rather

  20. Effect of Exposure to Atmospheric Ultrafine Particles on Production of Free Fatty Acids and Lipid Metabolites in the Mouse Small Intestine

    PubMed Central

    Li, Rongsong; Navab, Kaveh; Hough, Greg; Daher, Nancy; Zhang, Min; Mittelstein, David; Lee, Katherine; Pakbin, Payam; Saffari, Arian; Bhetraratana, May; Sulaiman, Dawoud; Beebe, Tyler; Wu, Lan; Jen, Nelson; Wine, Eytan; Tseng, Chi-Hong; Araujo, Jesus A.; Fogelman, Alan; Sioutas, Constantinos; Navab, Mohamed

    2014-01-01

    Background: Exposure to ambient ultrafine particulate matter (UFP) is a well-recognized risk factor for cardiovascular and respiratory diseases. However, little is known about the effects of air pollution on gastrointestinal disorders. Objective: We sought to assess whether exposure to ambient UFP (diameter < 180 nm) increased free fatty acids and lipid metabolites in the mouse small intestine. Methods: Ldlr-null mice were exposed to filtered air (FA) or UFP collected at an urban Los Angeles, California, site that was heavily affected by vehicular emissions; the exposure was carried out for 10 weeks in the presence or absence of D-4F, an apolipoprotein A-I mimetic peptide with antioxidant and anti-inflammation properties on a high-fat or normal chow diet. Results: Compared with FA, exposure to UFP significantly increased intestinal hydroxyeicosatetraenoic acids (HETEs), including 15-HETE, 12-HETE, 5-HETE, as well as hydroxyoctadecadienoic acids (HODEs), including 13-HODE and 9-HODE. Arachidonic acid (AA) and prostaglandin D2 (PGD2) as well as some of the lysophosphatidic acids (LPA) in the small intestine were also increased in response to UFP exposure. Administration of D-4F significantly reduced UFP-mediated increase in HETEs, HODEs, AA, PGD2, and LPA. Although exposure to UFP further led to shortened villus length accompanied by prominent macrophage and neutrophil infiltration into the intestinal villi, administration of D-4F mitigated macrophage infiltration. Conclusions: Exposure to UFP promotes lipid metabolism, villus shortening, and inflammatory responses in mouse small intestine, whereas administration of D-4F attenuated these effects. Our findings provide a basis to further assess the mechanisms underlying UFP-mediated lipid metabolism in the digestive system with clinical relevance to gut homeostasis and diseases. Citation: Li R, Navab K, Hough G, Daher N, Zhang M, Mittelstein D, Lee K, Pakbin P, Saffari A, Bhetraratana M, Sulaiman D, Beebe T, Wu L, Jen

  1. Heterogeneity of passenger exposure to air pollutants in public transport microenvironments

    NASA Astrophysics Data System (ADS)

    Yang, Fenhuan; Kaul, Daya; Wong, Ka Chun; Westerdahl, Dane; Sun, Li; Ho, Kin-fai; Tian, Linwei; Brimblecombe, Peter; Ning, Zhi

    2015-05-01

    Epidemiologic studies have linked human exposure to pollutants with adverse health effects. Passenger exposure in public transport systems contributes an important fraction of daily burden of air pollutants. While there is extensive literature reporting the concentrations of pollutants in public transport systems in different cities, there are few studies systematically addressing the heterogeneity of passenger exposure in different transit microenvironments, in cabins of different transit vehicles and in areas with different characteristics. The present study investigated PM2.5 (particulate matter with aerodynamic diameters smaller than 2.5 μm), black carbon (BC), ultrafine particles (UFP) and carbon monoxide (CO) pollutant concentrations in various public road transport systems in highly urbanized city of Hong Kong. Using a trolley case housing numerous portable air monitors, we conducted a total of 119 trips during the campaign. Transit microenvironments, classified as 1). busy and secondary roadside bus stops; 2). open and enclosed termini; 3). above- and under-ground Motor Rail Transport (MTR) platforms, were investigated and compared to identify the factors that may affect passenger exposures. The pollutants inside bus and MTR cabins were also investigated together with a comparison of time integrated exposure between the transit modes. Busy roadside and enclosed termini demonstrated the highest average particle concentrations while the lowest was found on the MTR platforms. Traffic-related pollutants BC, UFP and CO showed larger variations than PM2.5 across different microenvironments and areas confirming their heterogeneity in urban environments. In-cabin pollutant concentrations showed distinct patterns with BC and UFP high in diesel bus cabins and CO high in LPG bus cabins, suggesting possible self-pollution issues and/or penetration of on-road pollutants inside cabins during bus transit. The total passenger exposure along selected routes, showed bus

  2. A Jagged 1-Notch 4 molecular switch mediates airway inflammation induced by ultrafine particles.

    PubMed

    Xia, Mingcan; Harb, Hani; Saffari, Arian; Sioutas, Constantinos; Chatila, Talal A

    2018-04-05

    Exposure to traffic-related particulate matter promotes asthma and allergic diseases. However, the precise cellular and molecular mechanisms by which particulate matter exposure acts to mediate these effects remain unclear. We sought to elucidate the cellular targets and signaling pathways critical for augmentation of allergic airway inflammation induced by ambient ultrafine particles (UFP). We used in vitro cell-culture assays with lung-derived antigen-presenting cells and allergen-specific T cells and in vivo mouse models of allergic airway inflammation with myeloid lineage-specific gene deletions, cellular reconstitution approaches, and antibody inhibition studies. We identified lung alveolar macrophages (AM) as the key cellular target of UFP in promoting airway inflammation. Aryl hydrocarbon receptor-dependent induction of Jagged 1 (Jag1) expression in AM was necessary and sufficient for augmentation of allergic airway inflammation by UFP. UFP promoted T H 2 and T H 17 cell differentiation of allergen-specific T cells in a Jag1- and Notch 4-dependent manner. Treatment of mice with an anti-Notch 4 antibody abrogated exacerbation of allergic airway inflammation induced by UFP. UFP exacerbate allergic airway inflammation by promoting a Jag1-Notch 4-dependent interaction between AM and allergen-specific T cells, leading to augmented T H cell differentiation. Copyright © 2018 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. Long-term study of urban ultrafine particles and other pollutants

    NASA Astrophysics Data System (ADS)

    Wang, Yungang; Hopke, Philip K.; Chalupa, David C.; Utell, Mark J.

    2011-12-01

    Continuous measurements of number size distributions of ultrafine particles (UFPs) and other pollutants (PM 2.5, SO 2, CO and O 3) have been performed in Rochester, New York since late November 2001. The 2002-2009 average number concentrations of particles in three size ranges (10-50 nm, 50-100 nm and 100-500 nm) were 4730 cm -3, 1838 cm -3, and 1073 cm -3, respectively. The lowest annual average number concentrations of particles in 10-50 nm and 50-100 nm were observed during 2008-2009. The lowest monthly average number concentration of 10-50 nm particles was observed in July and the highest in February. The daily patterns of 10-50 nm particles had two peaks at early morning (7-8 AM) and early afternoon (2 PM). There was a distinct declining trend in the peak number concentrations from 2002-2005 to 2008-2009. Large reductions in SO 2 concentrations associated with northerly winds between 2007 and 2009 were observed. The most significant annual decrease in the frequency of morning particle nucleation was observed from 2005 to 2007. The monthly variation in the morning nucleation events showed a close correlation with number concentrations of 10-50 nm particles ( r = 0.89). The frequency of the local SO 2-related nucleation events was much higher before 2006. All of these results suggest significant impacts of highway traffic and industrial sources. The decrease in particle number concentrations and particle nucleation events likely resulted from a combination of the U.S. EPA 2007 Heavy-Duty Highway Rule implemented on October 1, 2006, the closure of a large coal-fired power plant in May 2008, and the reduction of Eastman Kodak emissions.

  4. Global Distribution of Cloud Droplet Number Concentration, Autoconversion Rate, and Aerosol Indirect Effect Under Diabatic Droplet Activation

    NASA Technical Reports Server (NTRS)

    Barahona, Donifan; Sotiropoulou, Rafaella; Nenes, Athanasios

    2011-01-01

    This study presents a global assessment of the sensitivity of droplet number to diabatic activation (i.e., including effects from entrainment of dry air) and its first-order tendency on indirect forcing and autoconversion. Simulations were carried out with the NASA Global Modeling Initiative (GMI) atmospheric and transport model using climatological metereorological fields derived from the former NASA Data Assimilation Office (DAO), the NASA Finite volume GCM (FVGCM) and the Goddard Institute for Space Studies version II (GISS) GCM. Cloud droplet number concentration (CDNC) is calculated using a physically based prognostic parameterization that explicitly includes entrainment effects on droplet formation. Diabatic activation results in lower CDNC, compared to adiabatic treatment of the process. The largest decrease in CDNC (by up to 75 percent) was found in the tropics and in zones of moderate CCN concentration. This leads to a global mean effective radius increase between 0.2-0.5 micrometers (up to 3.5 micrometers over the tropics), a global mean autoconversion rate increase by a factor of 1.1 to 1.7 (up to a factor of 4 in the tropics), and a 0.2-0.4 W m(exp -2) decrease in indirect forcing. The spatial patterns of entrainment effects on droplet activation tend to reduce biases in effective radius (particularly in the tropics) when compared to satellite retrievals. Considering the diabatic nature of ambient clouds, entrainment effects on CDNC need to be considered in GCM studies of the aerosol indirect effect.

  5. Differential pattern of deposition of nanoparticles in the airways of exposed workers

    NASA Astrophysics Data System (ADS)

    Fireman, Elizabeth; Edelheit, Rinat; Stark, Moshe; Shai, Amir Bar

    2017-02-01

    Ultrafine particles (UFP) have been postulated to significantly contribute to the adverse health effects associated with exposure to particulate matter (PM). Due to their extremely small size (aerodynamic diameter <100 nm), UFP are able to deposit deep within the lung after inhalation and evade many mechanisms responsible for the clearance of larger particles. There is a lack of biologically relevant personal exposure metrics for exposure to occupational- and environmental-related micro- and nano-sized PM. The aim of the present study is to assess UFP in induced sputum (IS) and exhaled breath condensate (EBC) as possible biomarkers for assessing lung function impairment. Sputum induction and EBC testing were performed by conventional methods. UFP particles were assessed with the NanoSight LM20 (NanoSight Ltd, London, UK). The subjects included 35 exposed and 25 non-exposed workers. There were no group differences in pulmonary function test results and differential cell counts, but 63.6% of the exposed subjects had a higher percentage of neutrophils (OR3.28 p = 0.03) compared to the non-exposed subjects. The exposed subjects had higher percentages of UFP between 10 and 50 nm (69.45 ± 18.70 vs 60.11 ± 17.52 for the non-exposed group, p = 0.004). No differences were found in the IS samples. Years of exposure correlated positively to UFP content ( r = 0.342 p = 0.01) and macrophage content ( r = -0.327 p = 0.03). The percentage of small fraction of UFP in EBC, but not IS, is higher in exposed workers, and EBC may be a sensitive biomarker to assess exposure to nanoparticles.

  6. The effects of leaf size and microroughness on the branch-scale collection efficiency of ultrafine particles

    DOE PAGES

    Huang, C. W.; Lin, M. Y.; Khlystov, A.; ...

    2015-03-02

    In this study, wind tunnel experiments were performed to explore how leaf size and leaf microroughness impact the collection efficiency of ultrafine particles (UFP) at the branch scale. A porous media model previously used to characterize UFP deposition onto conifers (Pinus taeda and Juniperus chinensis) was employed to interpret these wind tunnel measurements for four different broadleaf species (Ilex cornuta, Quercus alba, Magnolia grandiflora, and Lonicera fragrantissima) and three wind speed (0.3–0.9 ms -1) conditions. Among the four broadleaf species considered, Ilex cornuta with its partially folded shape and sharp edges was the most efficient at collecting UFP followed bymore » the other three flat-shaped broadleaf species. The findings here suggest that a connection must exist between UFP collection and leaf dimension and roughness. This connection is shown to be primarily due to the thickness of a quasi-laminar boundary layer pinned to the leaf surface assuming the flow over a leaf resembles that of a flat plate. A scaling analysis that utilizes a three-sublayer depositional model for a flat plate of finite size and roughness embedded within the quasi-laminar boundary layer illustrates these connections. The analysis shows that a longer leaf dimension allows for thicker quasi-laminar boundary layers to develop. A thicker quasi-laminar boundary layer depth in turn increases the overall resistance to UFP deposition due to an increase in the diffusional path length thereby reducing the leaf-scale UFP collection efficiency. Finally, it is suggested that the effects of leaf microroughness are less relevant to the UFP collection efficiency than are the leaf dimensions for the four broadleaf species explored here.« less

  7. The impact of undergraduate clinical teaching models on the perceptions of work-readiness among new graduate nurses: A cross sectional study.

    PubMed

    Patterson, Emma E B; Boyd, Leanne; Mnatzaganian, George

    2017-08-01

    Clinical Placements are an essential component of bridging the gap between academic theory and nursing practice. There are multiple clinical models designed to ease the transition from student to professional, yet there has been little exploration of such models and their impact on graduates' perceptions of work-readiness. This cross sectional study examined perceptions of work-readiness of new graduate nurses who attended one of the following clinical teaching models: the University Fellowship Program (UFP), the Traditional Multi-facility Clinical Model (TMCPM), and the Mixed Program (MP). Three groups of first year graduate nurses (UFP, TMCPM, and MP) were compared using the Work-readiness Scale, a validated and reliable tool, which assessed nurses' perceptions of work-readiness in four domains: organizational acumen, personal work characteristics, social intelligence, and work competence. A multivariable Generalized Estimating Equations regression investigated socio-demographic and teaching-modelrelated factors associated with work-readiness. Of 43 nurses approached, 28 completed the survey (65% response rate) of whom 6 were UFP attendants, 8 attended the TMCPM and 14 the MP. Those who had attended the UFP scored higher than the other two in all four domains; however, the crude between-group comparisons did not yield statistically significant results. Only after accounting for age, gender, teaching setting and prior work experience, the multivariable model showed that undertaking the UFP was likely to increase perceptions of work-readiness by 1.4 points (95% CI 0.11-2.69), P=0.03). The UFP was superior to the other two placement models. The study suggests that the UFP may enhance graduate nurses' perceptions of work readiness. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. The effects of leaf size and microroughness on the branch-scale collection efficiency of ultrafine particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, C. W.; Lin, M. Y.; Khlystov, A.

    In this study, wind tunnel experiments were performed to explore how leaf size and leaf microroughness impact the collection efficiency of ultrafine particles (UFP) at the branch scale. A porous media model previously used to characterize UFP deposition onto conifers (Pinus taeda and Juniperus chinensis) was employed to interpret these wind tunnel measurements for four different broadleaf species (Ilex cornuta, Quercus alba, Magnolia grandiflora, and Lonicera fragrantissima) and three wind speed (0.3–0.9 ms -1) conditions. Among the four broadleaf species considered, Ilex cornuta with its partially folded shape and sharp edges was the most efficient at collecting UFP followed bymore » the other three flat-shaped broadleaf species. The findings here suggest that a connection must exist between UFP collection and leaf dimension and roughness. This connection is shown to be primarily due to the thickness of a quasi-laminar boundary layer pinned to the leaf surface assuming the flow over a leaf resembles that of a flat plate. A scaling analysis that utilizes a three-sublayer depositional model for a flat plate of finite size and roughness embedded within the quasi-laminar boundary layer illustrates these connections. The analysis shows that a longer leaf dimension allows for thicker quasi-laminar boundary layers to develop. A thicker quasi-laminar boundary layer depth in turn increases the overall resistance to UFP deposition due to an increase in the diffusional path length thereby reducing the leaf-scale UFP collection efficiency. Finally, it is suggested that the effects of leaf microroughness are less relevant to the UFP collection efficiency than are the leaf dimensions for the four broadleaf species explored here.« less

  9. Land use regression modeling of ultrafine particles, ozone, nitrogen oxides and markers of particulate matter pollution in Augsburg, Germany.

    PubMed

    Wolf, Kathrin; Cyrys, Josef; Harciníková, Tatiana; Gu, Jianwei; Kusch, Thomas; Hampel, Regina; Schneider, Alexandra; Peters, Annette

    2017-02-01

    Important health relevance has been suggested for ultrafine particles (UFP) and ozone, but studies on long-term effects are scarce, mainly due to the lack of appropriate spatial exposure models. We designed a measurement campaign to develop land use regression (LUR) models to predict the spatial variability focusing on particle number concentration (PNC) as indicator for UFP, ozone and several other air pollutants in the Augsburg region, Southern Germany. Three bi-weekly measurements of PNC, ozone, particulate matter (PM 10 , PM 2.5 ), soot (PM 2.5 abs) and nitrogen oxides (NO x , NO 2 ) were performed at 20 sites in 2014/15. Annual average concentration were calculated and temporally adjusted by measurements from a continuous background station. As geographic predictors we offered several traffic and land use variables, altitude, population and building density. Models were validated using leave-one-out cross-validation. Adjusted model explained variance (R 2 ) was high for PNC and ozone (0.89 and 0.88). Cross-validation adjusted R 2 was slightly lower (0.82 and 0.81) but still indicated a very good fit. LUR models for other pollutants performed well with adjusted R 2 between 0.68 (PM coarse ) and 0.94 (NO 2 ). Contrary to previous studies, ozone showed a moderate correlation with NO 2 (Pearson's r=-0.26). PNC was moderately correlated with ozone and PM 2.5 , but highly correlated with NO x (r=0.91). For PNC and NO x , LUR models comprised similar predictors and future epidemiological analyses evaluating health effects need to consider these similarities. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. [Ultrafine particles and effects on the body: review of the literature].

    PubMed

    Pedata, P; Garzillo, E M; Sannolo, N

    2010-01-01

    The International laws and the technology developments led to a situation where the current levels of environmental pollution are below those that existed at the beginning of the century: however, these pollution levels produce harmful effects to health linked to an increase in morbidity and mortality. Over the years the pollution has changed: following the transformation of heating, motor innovation and emissions reducing, has been a reduction in air concentration of some conventional pollutants (sulfur dioxide, carbon monoxide, benzene), while there wasn't a significant reduction of particulate air pollution. In this work have been questioned several electronic databases of scientific literature based on a selection algorithm that contains expressions for the following topics: "ultrafine particles", "effects on human health", "occupational and environmental exposure". We analyzed 200 articles, progressively reduced to 88, selected for keywords, year of publication and arguments; the main topics covered by the articles were related to chemical and physical UFP properties, UFP exposure, European legislation relating to the values of particle concentrations in the atmosphere, toxicokinetics and effects on various organs such as, in particular, the respiratory system, cardiovascular system, central nervous system and the intracellular mechanism of action. Analysis of the literature showed that ultrafine particles (PM0.1 aerodynamic diameter less than 0.1 microm) are more powerful than the coarse particle fraction (2.5-10 microm) and fine (0.1-2.5 microm) in inducing adverse effects to human health. Unfortunately, the study of mechanisms of action of these particles presents particular difficulties because of the large number of chemical and biological mechanisms that come into play in the body after exposure to ultrafine particles.

  11. Characterisation of Exposure to Ultrafine Particles from Surgical Smoke by Use of a Fast Mobility Particle Sizer.

    PubMed

    Ragde, Siri Fenstad; Jørgensen, Rikke Bramming; Føreland, Solveig

    2016-08-01

    Electrosurgery is a method based on a high frequency current used to cut tissue and coagulate small blood vessels during surgery. Surgical smoke is generated due to the heat created by electrosurgery. The carcinogenic potential of this smoke was assumed already in the 1980's and there has been a growing interest in the potential adverse health effects of exposure to the particles in surgical smoke. Surgical smoke is known to contain ultrafine particles (UFPs) but the knowledge about the exposure to UFPs produced by electrosurgery is however sparse. The aims of the study were therefore to characterise the exposure to UFPs in surgical smoke during different types of surgical procedures and on different job groups in the operating room, and to characterise the particle size distribution. Personal exposure measurements were performed on main surgeon, assistant surgeon, surgical nurse, and anaesthetic nurse during five different surgical procedures [nephrectomy, breast reduction surgery, abdominoplasty, hip replacement surgery, and transurethral resection of the prostate (TURP)]. The measurements were performed with a Fast Mobility Particle Sizer (FMPS) to assess the exposure to UPFs and to characterize the particle size distribution. Possible predictors of exposure were investigated using Linear Mixed Effect Models. The exposure to UFPs was highest during abdominoplasty arithmetic mean (AM) 3900 particles cm(-3) and lowest during hip replacement surgeries AM 400 particles cm(-3). The different job groups had similar exposure during the same types of surgical procedures. The use of electrosurgery resulted in short term high peak exposure (highest maximum peak value 272 000 particles cm(-3)) to mainly UFPs. The size distribution of particles varied between the different types of surgical procedures, where nephrectomy, hip replacement surgery, and TURP produced UFPs with a dominating mode of 9nm while breast reduction surgery and abdominoplasty produced UFPs with a

  12. Desorption of SVOCs from Heated Surfaces in the Form of Ultrafine Particles.

    PubMed

    Wallace, Lance A; Ott, Wayne R; Weschler, Charles J; Lai, Alvin C K

    2017-02-07

    Ultrafine particles (UFP) produced by electric heating of stoves and metal cooking pans, absent food, have been hypothesized to be created from a surface film of semivolatile organic compounds (SVOCs) sorbed from the surrounding air. This study tests that hypothesis by size-resolved measurements extending the lower range of the UFP studied from 10 to 2.3 nm, and including other surfaces (glass, aluminum, and porcelain). Heating glass Petri dishes or squares of aluminum foil to about 350-400 °C for 4-6 min removed all sorbed organic substances completely. Subsequent exposure of these "clean" Petri dishes and foil squares to indoor air in two different residences for successively longer periods (1 h to 281 days), followed by heating the materials for 4-6 min, indicated a strong relationship of the number, size distribution, and mass of the UFP to the time exposed. Estimates of the accumulation rate of SVOCs on surfaces were similar to those in studies of organic film buildup on indoor windows. Transfer of skin oils by touching the glass or foil surfaces, or after washing the glass surface with detergent and bare hands, was also observed, with measured particle production comparable with that produced by long-term exposure to indoor air.

  13. Quantitating Changes in Jitter and Spike Number Using Concentric Needle Electrodes in Amyotrophic Lateral Sclerosis Patients

    PubMed Central

    Liu, Ming-Sheng; Niu, Jing-Wen; Li, Yi; Guan, Yu-Zhou; Cui, Li-Ying

    2016-01-01

    Background: Single-fiber electromyography (SFEMG) has been suggested as a quantitative method for supporting chronic partial denervation in amyotrophic lateral sclerosis (ALS) by the revised EI Escorial criteria. Although concentric needle (CN) electrodes have been used to assess jitter in myasthenia gravis patients and healthy controls, there are few reports using CN electrodes to assess motor unit instability and denervation in neurogenic diseases. The aim of this study was to determine whether quantitative changes in jitter and spike number using CN electrodes could be used for ALS studies. Methods: Twenty-seven healthy controls and 23 ALS patients were studied using both CN and single-fiber needle (SFN) electrodes on the extensor digitorum communis muscle with an SFEMG program. The SFN-jitter and SFN-fiber density data were measured using SFN electrodes. The CN-jitter and spike number were measured using CN electrodes. Results: The mean CN-jitter was significantly increased in ALS patients (47.3 ± 17.0 μs) than in healthy controls (27.4 ± 3.3 μs) (P < 0.001). Besides, the mean spike number was significantly increased in ALS patients (2.5 ± 0.5) than in healthy controls (1.7 ± 0.3) (P < 0.001). The sensitivity and specificity in the diagnosis of ALS were 82.6% and 92.6% for CN-jitter (cut-off value: 32 μs), and 91.3% and 96.3% for the spike number (cut-off value: 2.0), respectively. There was no significant difference between the SFN-jitter and CN-jitter in ALS patients; meanwhile, there was no significant difference between the SFN-jitter and CN-jitter in healthy controls. Conclusion: CN-jitter and spike number could be used to quantitatively evaluate changes due to denervation-reinnervation in ALS. PMID:27098787

  14. Characteristics of PM2.5, CO2 and particle-number concentration in mass transit railway carriages in Hong Kong.

    PubMed

    Zheng, Hai-Long; Deng, Wen-Jing; Cheng, Yan; Guo, Wei

    2017-08-01

    Fine particulate matter (PM 2.5 ) levels, carbon dioxide (CO 2 ) levels and particle-number concentrations (PNC) were monitored in train carriages on seven routes of the mass transit railway in Hong Kong between March and May 2014, using real-time monitoring instruments. The 8-h average PM 2.5 levels in carriages on the seven routes ranged from 24.1 to 49.8 µg/m 3 , higher than levels in Finland and similar to those in New York, and in most cases exceeding the standard set by the World Health Organisation (25 µg/m 3 ). The CO 2 concentration ranged from 714 to 1801 ppm on four of the routes, generally exceeding indoor air quality guidelines (1000 ppm over 8 h) and reaching levels as high as those in Beijing. PNC ranged from 1506 to 11,570 particles/cm 3 , lower than readings in Sydney and higher than readings in Taipei. Correlation analysis indicated that the number of passengers in a given carriage did not affect the PM 2.5 concentration or PNC in the carriage. However, a significant positive correlation (p < 0.001, R 2  = 0.834) was observed between passenger numbers and CO 2 levels, with each passenger contributing approximately 7.7-9.8 ppm of CO 2 . The real-time measurements of PM 2.5 and PNC varied considerably, rising when carriage doors opened on arrival at a station and when passengers inside the carriage were more active. This suggests that air pollutants outside the train and passenger movements may contribute to PM 2.5 levels and PNC. Assessment of the risk associated with PM 2.5 exposure revealed that children are most severely affected by PM 2.5 pollution, followed in order by juveniles, adults and the elderly. In addition, females were found to be more vulnerable to PM 2.5 pollution than males (p < 0.001), and different subway lines were associated with different levels of risk.

  15. Manufactured and Airborne Nanoparticle Cardiopulmonary Interactions: A Review of Mechanisms and the Possible Contribution of Mast Cells

    EPA Science Inventory

    Human inhalation exposures to manufactured nanoparticles (NP) and airborne ultrafine particles (UFP) continues to increase in both occupational and environmental settings. UFP exposures have been associated with increased cardiovascular mortality and morbidity, while ongoing res...

  16. Highway proximity associated with cardiovascular disease risk: the influence of individual-level confounders and exposure misclassification

    PubMed Central

    2013-01-01

    Background Elevated cardiovascular disease risk has been reported with proximity to highways or busy roadways, but proximity measures can be challenging to interpret given potential confounders and exposure error. Methods We conducted a cross sectional analysis of plasma levels of C-Reactive Protein (hsCRP), Interleukin-6 (IL-6), Tumor Necrosis Factor alpha receptor II (TNF-RII) and fibrinogen with distance of residence to a highway in and around Boston, Massachusetts. Distance was assigned using ortho-photo corrected parcel matching, as well as less precise approaches such as simple parcel matching and geocoding addresses to street networks. We used a combined random and convenience sample of 260 adults >40 years old. We screened a large number of individual-level variables including some infrequently collected for assessment of highway proximity, and included a subset in our final regression models. We monitored ultrafine particle (UFP) levels in the study areas to help interpret proximity measures. Results Using the orthophoto corrected geocoding, in a fully adjusted model, hsCRP and IL-6 differed by distance category relative to urban background: 43% (-16%,141%) and 49% (6%,110%) increase for 0-50 m; 7% (-39%,45%) and 41% (6%,86%) for 50-150 m; 54% (-2%,142%) and 18% (-11%,57%) for 150-250 m, and 49% (-4%, 131%) and 42% (6%, 89%) for 250-450 m. There was little evidence for association for TNF-RII or fibrinogen. Ortho-photo corrected geocoding resulted in stronger associations than traditional methods which introduced differential misclassification. Restricted analysis found the effect of proximity on biomarkers was mostly downwind from the highway or upwind where there was considerable local street traffic, consistent with patterns of monitored UFP levels. Conclusion We found associations between highway proximity and both hsCRP and IL-6, with non-monotonic patterns explained partly by individual-level factors and differences between proximity and UFP

  17. Highway proximity associated with cardiovascular disease risk: the influence of individual-level confounders and exposure misclassification.

    PubMed

    Brugge, Doug; Lane, Kevin; Padró-Martínez, Luz T; Stewart, Andrea; Hoesterey, Kyle; Weiss, David; Wang, Ding Ding; Levy, Jonathan I; Patton, Allison P; Zamore, Wig; Mwamburi, Mkaya

    2013-10-03

    Elevated cardiovascular disease risk has been reported with proximity to highways or busy roadways, but proximity measures can be challenging to interpret given potential confounders and exposure error. We conducted a cross sectional analysis of plasma levels of C-Reactive Protein (hsCRP), Interleukin-6 (IL-6), Tumor Necrosis Factor alpha receptor II (TNF-RII) and fibrinogen with distance of residence to a highway in and around Boston, Massachusetts. Distance was assigned using ortho-photo corrected parcel matching, as well as less precise approaches such as simple parcel matching and geocoding addresses to street networks. We used a combined random and convenience sample of 260 adults >40 years old. We screened a large number of individual-level variables including some infrequently collected for assessment of highway proximity, and included a subset in our final regression models. We monitored ultrafine particle (UFP) levels in the study areas to help interpret proximity measures. Using the orthophoto corrected geocoding, in a fully adjusted model, hsCRP and IL-6 differed by distance category relative to urban background: 43% (-16%,141%) and 49% (6%,110%) increase for 0-50 m; 7% (-39%,45%) and 41% (6%,86%) for 50-150 m; 54% (-2%,142%) and 18% (-11%,57%) for 150-250 m, and 49% (-4%, 131%) and 42% (6%, 89%) for 250-450 m. There was little evidence for association for TNF-RII or fibrinogen. Ortho-photo corrected geocoding resulted in stronger associations than traditional methods which introduced differential misclassification. Restricted analysis found the effect of proximity on biomarkers was mostly downwind from the highway or upwind where there was considerable local street traffic, consistent with patterns of monitored UFP levels. We found associations between highway proximity and both hsCRP and IL-6, with non-monotonic patterns explained partly by individual-level factors and differences between proximity and UFP concentrations. Our analyses emphasize

  18. Air toxics exposure from vehicle emissions at a U.S. border crossing: Buffalo Peace Bridge Study.

    PubMed

    Spengler, John; Lwebuga-Mukasa, Jamson; Vallarino, Jose; Melly, Steve; Chillrud, Steve; Baker, Joel; Minegishi, Taeko

    2011-07-01

    The Peace Bridge in Buffalo, New York, which spans the Niagara River at the east end of Lake Erie, is one of the busiest U.S. border crossings. The Peace Bridge plaza on the U.S. side is a complex of roads, customs inspection areas, passport control areas, and duty-free shops. On average 5000 heavy-duty diesel trucks and 20,000 passenger cars traverse the border daily, making the plaza area a potential "hot spot" for emissions from mobile sources. In a series of winter and summer field campaigns, we measured air pollutants, including many compounds considered by the U.S. Environmental Protection Agency (EPA*) as mobile-source air toxics (MSATs), at three fixed sampling sites: on the shore of Lake Erie, approximately 500 m upwind (under predominant wind conditions) of the Peace Bridge plaza; immediately downwind of (adjacent to) the plaza; and 500 m farther downwind, into the community of west Buffalo. Pollutants sampled were particulate matter (PM) < or = 10 microm (PM10) and < or = 2.5 microm (PM2.5) in aerodynamic diameter, elemental carbon (EC), 28 elements, 25 volatile organic compounds (VOCs) including 3 carbonyls, 52 polycyclic aromatic hydrocarbons (PAHs), and 29 nitrogenated polycyclic aromatic hydrocarbons (NPAHs). Spatial patterns of counts of ultrafine particles (UFPs, particles < 0.1 microm in aerodynamic diameter) and of particle-bound PAH (pPAH) concentrations were assessed by mobile monitoring in the neighborhood adjacent to the Peace Bridge plaza using portable instruments and Global Positioning System (GPS) tracking. The study was designed to assess differences in upwind and downwind concentrations of MSATs, in areas near the Peace Bridge plaza on the U.S. side of the border. The Buffalo Peace Bridge Study featured good access to monitoring locations proximate to the plaza and in the community, which are downwind with the dominant winds from the direction of Lake Erie and southern Ontario. Samples from the lakeside Great Lakes Center (GLC), which

  19. Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom

    NASA Astrophysics Data System (ADS)

    Guo, H.; Morawska, L.; He, C.; Gilbert, D.

    A 2-week intensive measurement campaign of indoor and outdoor air pollution was carried out in September 2006, in a primary school to investigate indoor-outdoor correlations of particle number (PN) concentrations, and the impact of air exchange rate (ACH) on the indoor PN concentration. The ACHs in the classroom for different conditions associated with window opening and the operational status of air conditioners (A/C) and fans were tested. As expected, the lowest ACH (0.12 h -1) was found when the windows were closed and A/C and fans were off. In contrast, the highest ACH (7.92 h -1) was observed when the windows were opened and A/C and fans were all on. The analysis of the PN I/ O ratios at different ACHs in the absence of indoor sources indicates that the mean I/ O ratio was 0.621±0.007 (mean±95% confidence interval) when the windows were closed, and A/C and fans were off; 0.524±0.023 when windows were closed, fans were off and A/C was on; and 0.502±0.029 when windows were closed, A/C was off and fans were on. To further understand the relationship between indoor and outdoor PN concentrations, the impact of outdoor PN concentration on I/ O ratios at different ACHs was investigated. It was found that the relationship between outdoor PN concentration and the I/ O ratio at different ACHs followed a power trendline with an equation of I/ O ratio= A PN out-b ( A and b are coefficients, PN out is outdoor PN concentration), suggesting that the penetration efficiency decreased with increasing outdoor PN concentration. It is the first time we found that when the outdoor PN concentration increased there was an associated increase in the concentration of nano-particles, which have been demonstrated to have higher deposition rates and lower penetration efficiencies. Based on the above equation, the study also showed a significant effect of ACH on indoor PN concentrations under stable outdoor PN concentrations. In general, the higher the ACH was, the lower the indoor PN

  20. Long-term exposure to ambient ultrafine particles and respiratory disease incidence in in Toronto, Canada: a cohort study.

    PubMed

    Weichenthal, Scott; Bai, Li; Hatzopoulou, Marianne; Van Ryswyk, Keith; Kwong, Jeffrey C; Jerrett, Michael; van Donkelaar, Aaron; Martin, Randall V; Burnett, Richard T; Lu, Hong; Chen, Hong

    2017-06-19

    Little is known about the long-term health effects of ambient ultrafine particles (<0.1 μm) (UFPs) including their association with respiratory disease incidence. In this study, we examined the relationship between long-term exposure to ambient UFPs and the incidence of lung cancer, adult-onset asthma, and chronic obstructive pulmonary disease (COPD). Our study cohort included approximately 1.1 million adults who resided in Toronto, Canada and who were followed for disease incidence between 1996 and 2012. UFP exposures were assigned to residential locations using a land use regression model. Random-effect Cox proportional hazard models were used to estimate hazard ratios (HRs) describing the association between ambient UFPs and respiratory disease incidence adjusting for ambient fine particulate air pollution (PM 2.5 ), NO 2 , and other individual/neighbourhood-level covariates. In total, 74,543 incident cases of COPD, 87,141 cases of asthma, and 12,908 cases of lung cancer were observed during follow-up period. In single pollutant models, each interquartile increase in ambient UFPs was associated with incident COPD (HR = 1.06, 95% CI: 1.05, 1.09) but not asthma (HR = 1.00, 95% CI: 1.00, 1.01) or lung cancer (HR = 1.00, 95% CI: 0.97, 1.03). Additional adjustment for NO 2 attenuated the association between UFPs and COPD and the HR was no longer elevated (HR = 1.01, 95% CI: 0.98, 1.03). PM 2.5 and NO 2 were each associated with increased incidence of all three outcomes but risk estimates for lung cancer were sensitive to indirect adjustment for smoking and body mass index. In general, we did not observe clear evidence of positive associations between long-term exposure to ambient UFPs and respiratory disease incidence independent of other air pollutants. Further replication is required as few studies have evaluated these relationships.

  1. The effects of blocking N/OFQ receptors on orofacial pain following experimental tooth movement in rats.

    PubMed

    Shan, Di; He, Yuwei; Long, Hu; Zhou, Yang; Liu, He; Xu, Rui; Huang, Renhuan; Lai, Wenli

    2016-11-01

    The aim of this study was to determine the effects of nociceptin/orphanin FQ peptide receptor (N/OFQ receptor) antagonist on orofacial pain induced by experimental tooth movement in rats. A total of 36 male Sprague-Dawley rats weighing 200-300 g were divided into six groups: a control group, force group, force+saline intraperitoneal group, force+saline periodontal group, force+UFP-101 ([Nphe¹,Arg¹⁴,Lys¹⁵]N/OFQ-NH ₂ antagonist for N/OFQ receptor) intraperitoneal group, and force+UFP-1 01 periodontal group. Closed coil springs were ligated between the upper incisors and first molar to exert an orthodontic force (40 g) between the teeth. Injectable administration dosages were 30 μl saline or 30 μl saline containing 0.03 mg/kg UFP-1 01. Following the injections, orofacial pain levels were assessed through directed face grooming (mouth wiping). Statistical analyses were performed in SPSS 17.0 (Statistical Package for the Social Sciences) and p values less than 0.05 were considered as statistically significant. Orofacial pain levels were significantly higher in the force group than in the control group. Orofacial pain levels differed significantly between the force)group, force+saline periodontal group and force+UFP-101 periodontal group, but were similar between the control group, force+UFP-101 intraperitoneal group and force+saline intraperitoneal group. Moreover, orofacial pain levels did not differ between the force group, force+saline intraperitoneal group and force+UFP-1 01 intraperitoneal group. Periodontal, but not intraperitoneal, administration of UFP-101 could alleviate orofacial pain induced by experimental tooth movement in rats, suggesting that periodontal N/OFQ receptors participate in orofacial pain induced by experimental tooth movement.

  2. Ambient ultrafine particle levels at residential and reference sites in urban and rural Switzerland.

    PubMed

    Meier, Reto; Eeftens, Marloes; Aguilera, Inmaculada; Phuleria, Harish C; Ineichen, Alex; Davey, Mark; Ragettli, Martina S; Fierz, Martin; Schindler, Christian; Probst-Hensch, Nicole; Tsai, Ming-Yi; Künzli, Nino

    2015-03-03

    Although there is evidence that ultrafine particles (UFP) do affect human health there are currently no legal ambient standards. The main reasons are the absence of spatially resolved exposure data to investigate long-term health effects and the challenge of defining representative reference sites for monitoring given the high dependence of UFP on proximity to sources. The objectives of this study were to evaluate the spatial distribution of UFP in four areas of the Swiss Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) and to investigate the representativeness of routine air monitoring stations for residential sites in these areas. Repeated UFP measurements during three seasons have been conducted at a total of 80 residential sites and four area specific reference sites over a median duration of 7 days. Arithmetic mean residential PNC scattered around the median of 10,800 particles/cm(3) (interquartile range [IQR] = 7800 particles/cm(3)). Spatial within area contrasts (90th/10th percentile ratios) were around two; increased contrasts were observed during weekday rush-hours. Temporal UFP patterns were comparable at reference and residential sites in all areas. Our data show that central monitoring sites can represent residential conditions when locations are well chosen with respect to the local sources--namely traffic. For epidemiological research, locally resolved spatial models are needed to estimate individuals' long-term exposures to UFP of outdoor origin at home, during commute and at work.

  3. Study on the number density of nanobubbles at varying concentration of ethanol in ethanol-water solution

    NASA Astrophysics Data System (ADS)

    Rajib, Md. Mahadi; Farzeen, Parisa; Ali, Mohammad

    2017-12-01

    In recent years, nanobubble technology has drawn great attention due to its extensive incorporation to substantial aspects of science and technology such as water treatment, drug delivery enhancement to cells, solvent and nutritional supplements manufacturing and many others. Bulk nanobubbles may be present in most aqueous solutions, possibly being constantly created by cosmic radiation and agitation and surface nanobubbles are present at most surfaces [1,2]. But, for utilizing these nanobubbles in a definitive way it's important to know whether an added amount of solution making substance has constructive or adverse effect on the nanobubble. In this work, the change of number density of nanobubbles in ethanol-water solution was studied by varying the ethanol concentration.

  4. Ultrafine Particulate Matter Increases Cardiac Ischemia/Reperfusion Injury via Mitochondrial Permeability Transition Pore.

    EPA Science Inventory

    Ultrafine Particulate Matter (UFP) has been associated with increased cardiovascular morbidity and mortality. However, the mechanisms that drive PM associated cardiovascular disease and dysfunction remain unclear. We examined the impact of intratracheal instillation of 100 g UFP...

  5. A modified Brownian force for ultrafine particle penetration through building crack modeling

    NASA Astrophysics Data System (ADS)

    Chen, Chen; Zhao, Bin

    2017-12-01

    Combustion processes related to industry, traffic, agriculture, and waste treatment and disposal increase the amount of outdoor ultrafine particles (UFPs), which have adverse effects on human health. Given that people spend the majority of their time indoors, it is critical to understand the penetration of outdoor UFPs through building cracks in order to estimate human exposure to outdoor-originated UFPs. Lagrangian tracking is an efficient approach for modeling particle penetration. However, the Brownian motion for Lagrangian tracking in ANSYS Fluent®, a widely used software for particle dispersion modeling, is not able to model UFP dispersion accurately. In this study, we modified the Brownian force by rewriting the Brownian diffusion coefficient and particle integration time step with a user-defined function in ANSYS Fluent® to model particle penetration through building cracks. The results obtained using the modified model agree much better with the experimental results, with the averaged relative error less than 14% for the smooth crack cases and 21% for the rough crack case. We expect the modified Brownian force model proposed herein to be applied for UFP dispersion modeling in more indoor air quality studies.

  6. OXIDATIVE STRESS AND LIPID MEDIATORS INDUCED IN ALVEOLAR MACHROPHAGES BY ULTRAFINE PARTICLES

    EPA Science Inventory

    In ambient aerosols, ultrafine particles (UFP) and their agglomerates are considered to be major factors contributing to adverse health effects. Reactivity of agglomerated UFP of elemental carbon (EC), Printex 90, Printex G, and diesel exhaust particles (DEP) was evaluated by the...

  7. Source appointment of fine particle number and volume concentration during severe haze pollution in Beijing in January 2013.

    PubMed

    Liu, Zirui; Wang, Yuesi; Hu, Bo; Ji, Dongsheng; Zhang, Junke; Wu, Fangkun; Wan, Xin; Wang, Yonghong

    2016-04-01

    Extreme haze episodes repeatedly shrouded Beijing during the winter of 2012-2013, causing major environmental and health problems. To better understand these extreme events, particle number size distribution (PNSD) and particle chemical composition (PCC) data collected in an intensive winter campaign in an urban site of Beijing were used to investigate the sources of ambient fine particles. Positive matrix factorization (PMF) analysis resolved a total of eight factors: two traffic factors, combustion factors, secondary aerosol, two accumulation mode aerosol factors, road dust, and long-range transported (LRT) dust. Traffic emissions (54%) and combustion aerosol (27%) were found to be the most important sources for particle number concentration, whereas combustion aerosol (33%) and accumulation mode aerosol (37%) dominated particle volume concentrations. Chemical compositions and sources of fine particles changed dynamically in the haze episodes. An enhanced role of secondary inorganic species was observed in the formation of haze pollution. Regional transport played an important role for high particles, contribution of which was on average up to 24-49% during the haze episodes. Secondary aerosols from urban background presented the largest contributions (45%) for the rapid increase of fine particles in the severest haze episode. In addition, the invasion of LRT dust aerosols further elevated the fine particles during the extreme haze episode. Our results showed a clear impact of regional transport on the local air pollution, suggesting the importance of regional-scale emission control measures in the local air quality management of Beijing.

  8. Phenology of a Vegetation Barrier and Resulting Impacts on Near-Highway Particle Number and Black Carbon Concentrations on a School Campus.

    PubMed

    Fuller, Christina H; Carter, David R; Hayat, Matthew J; Baldauf, Richard; Watts Hull, Rebecca

    2017-02-08

    Traffic-related air pollution is a persistent concern especially in urban areas where populations live in close proximity to roadways. Innovative solutions are needed to minimize human exposure and the installation of vegetative barriers shows potential as a method to reduce near-road concentrations. This study investigates the impact of an existing stand of deciduous and evergreen trees on near-road total particle number (PNC) and black carbon (BC) concentrations across three seasons. Measurements were taken during spring, fall and winter on the campus of a middle school in the Atlanta (GA, USA) area at distances of 10 m and 50 m from a major interstate highway. We identified consistent decreases in BC concentrations, but not for PNC, with increased distance from the highway. In multivariable models, hour of day, downwind conditions, distance to highway, temperature and relative humidity significantly predicted pollutant concentrations. The magnitude of effect of these variables differed by season, however, we were not able to show a definitive impact of the vegetative barrier on near-road concentrations. More detailed studies are necessary to further examine the specific configurations and scenarios that may produce pollutant and exposure reductions.

  9. Phenology of a Vegetation Barrier and Resulting Impacts on Near-Highway Particle Number and Black Carbon Concentrations on a School Campus

    PubMed Central

    Fuller, Christina H.; Carter, David R.; Hayat, Matthew J.; Baldauf, Richard; Watts Hull, Rebecca

    2017-01-01

    Traffic-related air pollution is a persistent concern especially in urban areas where populations live in close proximity to roadways. Innovative solutions are needed to minimize human exposure and the installation of vegetative barriers shows potential as a method to reduce near-road concentrations. This study investigates the impact of an existing stand of deciduous and evergreen trees on near-road total particle number (PNC) and black carbon (BC) concentrations across three seasons. Measurements were taken during spring, fall and winter on the campus of a middle school in the Atlanta (GA, USA) area at distances of 10 m and 50 m from a major interstate highway. We identified consistent decreases in BC concentrations, but not for PNC, with increased distance from the highway. In multivariable models, hour of day, downwind conditions, distance to highway, temperature and relative humidity significantly predicted pollutant concentrations. The magnitude of effect of these variables differed by season, however, we were not able to show a definitive impact of the vegetative barrier on near-road concentrations. More detailed studies are necessary to further examine the specific configurations and scenarios that may produce pollutant and exposure reductions. PMID:28208726

  10. Evaluation and modelling of the size fractionated aerosol particle number concentration measurements nearby a major road in Helsinki - Part I: Modelling results within the LIPIKA project

    NASA Astrophysics Data System (ADS)

    Pohjola, M. A.; Pirjola, L.; Karppinen, A.; Härkönen, J.; Korhonen, H.; Hussein, T.; Ketzel, M.; Kukkonen, J.

    2007-08-01

    A field measurement campaign was conducted near a major road "Itäväylä" in an urban area in Helsinki in 17-20 February 2003. Aerosol measurements were conducted using a mobile laboratory "Sniffer" at various distances from the road, and at an urban background location. Measurements included particle size distribution in the size range of 7 nm-10 μm (aerodynamic diameter) by the Electrical Low Pressure Impactor (ELPI) and in the size range of 3-50 nm (mobility diameter) by Scanning Mobility Particle Sizer (SMPS), total number concentration of particles larger than 3 nm detected by an ultrafine condensation particle counter (UCPC), temperature, relative humidity, wind speed and direction, driving route of the mobile laboratory, and traffic density on the studied road. In this study, we have compared measured concentration data with the predictions of the road network dispersion model CAR-FMI used in combination with an aerosol process model MONO32. For model comparison purposes, one of the cases was additionally computed using the aerosol process model UHMA, combined with the CAR-FMI model. The vehicular exhaust emissions, and atmospheric dispersion and transformation of fine and ultrafine particles was evaluated within the distance scale of 200 m (corresponding to a time scale of a couple of minutes). We computed the temporal evolution of the number concentrations, size distributions and chemical compositions of various particle size classes. The atmospheric dilution rate of particles is obtained from the roadside dispersion model CAR-FMI. Considering the evolution of total number concentration, dilution was shown to be the most important process. The influence of coagulation and condensation on the number concentrations of particle size modes was found to be negligible on this distance scale. Condensation was found to affect the evolution of particle diameter in the two smallest particle modes. The assumed value of the concentration of condensable organic

  11. Ultrafine particles near a major roadway in Raleigh, North Carolina: downwind attenuation and correlation with traffic-related pollutants

    EPA Science Inventory

    Ultrafine particles (UFPs, diameter <100 run) emitted by traffic are a potential direct health threat to nearby populations and may additionally act as a tracer for co-emitted pollutants. During summertime in Raleigh, North Carolina, UFPs were simultaneously measured upwind and d...

  12. Number concentration, size distribution and horizontal mass flux of Asian dust particles collected over free troposphere of Chinese desert region in calm weather condition using balloon borne measurements.

    NASA Astrophysics Data System (ADS)

    Habib, A.; Chen, B.

    2017-12-01

    Balloon borne measurements were carried out during calm weather conditions in Taklamakan Desert, which is considered as one of the major source areas of Asian dust (KOSA) particles. Vertical distribution of aerosols number concentration, size distribution, mass concentration and horizontal mass flux due to westerly wind was investigated .Vertical distribution of aerosol number concentration and size distribution at Dunhuang (40 °00'N, 94°30'E) China were observed by optical particle counter (OPC) on August 17, 2001, October 17, 2011, January 11, 2002, April 30, 2002. Five channels (0.3, 0.5, 0.8, 1.2 and 3.6 µm) were used in OPC for particle sizing measurements. Aerosol number concentration in winter season (January 11, 2002) at 3-5 km was very high. Variation of free tropospheric aerosols in April 30, 2002 was noticeable. Many inversions of temperature and aerosol concentration change are found at these inversion points. Super micron range was noticeable in size distribution of all balloon borne measurements. High values of estimated mass concentration of aerosols were observed at the ground atmosphere (1-2 km), and interestingly relatively high concentrations were frequently detected above about 2 km. Wind pattern observed by ERA-interim data sets at 500 and 850 hPa, shows that westerly winds were dominated in Taklamakan Desert during balloon borne observation period. Average horizontal mass flux of background Asian dust due to westerly wind was about in the range of 1219-58.5 μg/m³ tons/km2/day. Most of the profiles showed active transport of aerosols in the westerly dominated region, while, fluxes were found to be very low on January 11, 2002, compared with the other seasons. Vertical profiles of aerosols number concentration showed that significant transport of aerosols was dominated in westerly region (4-7 km). Low horizontal mass flux of aerosols was found in winter season

  13. Fuel-Flexible Gasification-Combustion Technology for Production of H2 and Sequestration-Ready CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Raul Subia

    GE Global Research is developing an innovative energy technology for coal gasification with high efficiency and near-zero pollution. This Unmixed Fuel Processor (UFP) technology simultaneously converts coal, steam and air into three separate streams of hydrogen-rich gas, sequestration-ready CO{sub 2}, and high-temperature, high-pressure vitiated air to produce electricity in gas turbines. This is the draft final report for the first stage of the DOE-funded Vision 21 program. The UFP technology development program encompassed lab-, bench- and pilot-scale studies to demonstrate the UFP concept. Modeling and economic assessments were also key parts of this program. The chemical and mechanical feasibility weremore » established via lab and bench-scale testing, and a pilot plant was designed, constructed and operated, demonstrating the major UFP features. Experimental and preliminary modeling results showed that 80% H{sub 2} purity could be achieved, and that a UFP-based energy plant is projected to meet DOE efficiency targets. Future work will include additional pilot plant testing to optimize performance and reduce environmental, operability and combined cycle integration risks. Results obtained to date have confirmed that this technology has the potential to economically meet future efficiency and environmental performance goals.« less

  14. Urban and rural ultrafine (PM 0.1) particles in the Helsinki area

    NASA Astrophysics Data System (ADS)

    Pakkanen, Tuomo A.; Kerminen, Veli-Matti; Korhonen, Christina H.; Hillamo, Risto E.; Aarnio, Päivi; Koskentalo, Tarja; Maenhaut, Willy

    In June 1996-June 1997 Berner low-pressure impactors were used at an urban and at a rural site in the Helsinki area for sampling ultrafine particles (UFP, PM 0.1). Ten sample pairs, each pair measured simultaneously, were collected in the size range of 0.03-15 μm of particle aerodynamic diameter. More than 40 chemical components were measured. Surprisingly, the average UFP mass concentration was higher at the rural site (520 ng/m 3) than at the urban site (490 ng/m 3). The average chemical composition of UFP was similar at the two sites. The most abundant of the measured components were sulphate (32 and 40 ng/m 3 for the urban and rural sites, respectively), ammonium (22 and 25 ng/m 3), nitrate (4 and 11 ng/m 3) and the Ca 2+ ion (5 and 7 ng/m 3). The most important metals at both sites were Ca, Na, Fe, K and Zn with concentrations between 0.7 and 5 ng/m 3. Of the heavy metals, Ni, V, Cu, and Pb were important with average ultrafine concentrations between about 0.1 and 0.2 ng/m 3. Also the organic anions oxalate (urban 2.1 ng/m 3 and rural 1.9 ng/m 3) and methanesulphonate (1.3 and 1.7 ng/m 3) contributed similarly at both sites. The measured species accounted for only about 15-20% of the total ultrafine mass. The fraction that was not measured includes mainly carbonaceous material and water. It was estimated that the amount of water was about 10% (50 ng/m 3) and that of carbonaceous material about 70% (350 ng/m 3) at both sites. Aitken modes were observed for most components with the average mass mean mode diameters being between about 0.06 and 0.12 μm. The average concentrations in the Aitken mode differed clearly from those in the UFP for several components. The average contribution of ultrafine mass to the fine particle mass (PM 2.5) was about 7% at the urban site and 8.5% at the rural site. At both sites the contribution of ultrafine to fine was especially high for Se, Ag, B, and Ni (10-20%) and at the rural site also for Co (20%), Ca 2+ (16%) and Mo (11

  15. Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments.

    PubMed

    Azimi, Parham; Zhao, Dan; Pouzet, Claire; Crain, Neil E; Stephens, Brent

    2016-02-02

    Previous research has shown that desktop 3D printers can emit large numbers of ultrafine particles (UFPs, particles less than 100 nm) and some hazardous volatile organic compounds (VOCs) during printing, although very few filament and 3D printer combinations have been tested to date. Here we quantify emissions of UFPs and speciated VOCs from five commercially available filament extrusion desktop 3D printers utilizing up to nine different filaments by controlled experiments in a test chamber. Median estimates of time-varying UFP emission rates ranged from ∼10(8) to ∼10(11) min(-1) across all tested combinations, varying primarily by filament material and, to a lesser extent, bed temperature. The individual VOCs emitted in the largest quantities included caprolactam from nylon-based and imitation wood and brick filaments (ranging from ∼2 to ∼180 μg/min), styrene from acrylonitrile butadiene styrene (ABS) and high-impact polystyrene (HIPS) filaments (ranging from ∼10 to ∼110 μg/min), and lactide from polylactic acid (PLA) filaments (ranging from ∼4 to ∼5 μg/min). Results from a screening analysis of potential exposure to these products in a typical small office environment suggest caution should be used when operating many of the printer and filament combinations in poorly ventilated spaces or without the aid of combined gas and particle filtration systems.

  16. An uncertainty analysis for satellite-based estimates of cloud condensation nuclei number concentrations

    NASA Astrophysics Data System (ADS)

    Shinozuka, Y.; Clarke, A. D.; Nenes, A.; Jefferson, A.; Wood, R.; McNaughton, C. S.; Ström, J.; Tunved, P.; Redemann, J.; Thornhill, K. L., II; Moore, R.; Lathem, T. L.; Lin, J.; Yoon, Y. J.

    2017-12-01

    Aerosol-cloud interactions (ACI) are the largest source of uncertainty in estimates of anthropogenic radiative forcing responsible for the on-going climate change. ACI for warm clouds depend on the number concentration of cloud condensation nuclei (CCN), not on aerosol optical properties. Yet, aerosol optical depth (AOD) and its variants weighted by the spectral dependence over visible and near infrared wavelengths are commonly substituted for CCN in ACI studies. The substitution is motivated by the wide availability in space and time of satellite retrievals, an advantage over the sparse CCN measurements. If satellite-based CCN estimates are to continue to complement purely model-based ones, what CCN-AOD relationship should we assume and how large is the associated uncertainty? Our 2015 paper examines airborne and ground-based observations of aerosols to address these questions, focusing on the relationship between CCN and light extinction, σ, of dried particles averaged over one-kilometer horizontal distance. That paper discusses the way the CCN-AOD relationship is influenced not only by the CCN-σ relationship but also by the humidity response of light extinction, the vertical profile, the horizontal-temporal variability and the AOD measurement error. In this presentation, we apply these findings to passive satellite data to analyze the uncertainty in satellite-based CCN estimates.

  17. CARDIOVASCULAR RESPONSES IN UNRESTRAINED WKY-RATS TO INHALED ULTRAFINE CARBON PARTICLES

    EPA Science Inventory

    Abstract
    This study provides evidence for adverse cardiac effects of inhaled ultrafine particles (UFPs) in healthy WKY rats. Short term exposure (24 h) with carbon UFPs (180 ?g?m ?) induced a moderate but significant heart rate increase of 18 bpm (4.8 %) in association with a ...

  18. Beyond PM2.5: The role of ultrafine particles on adverse health effects of air pollution.

    PubMed

    Chen, Rui; Hu, Bin; Liu, Ying; Xu, Jianxun; Yang, Guosheng; Xu, Diandou; Chen, Chunying

    2016-12-01

    Air pollution constitutes the major threat to human health, whereas their adverse impacts and underlying mechanisms of different particular matters are not clearly defined. Ultrafine particles (UFPs) are high related to the anthropogenic emission sources, i.e. combustion engines and power plants. Their composition, source, typical characters, oxidative effects, potential exposure routes and health risks were thoroughly reviewed. UFPs play a major role in adverse impacts on human health and require further investigations in future toxicological research of air pollution. Unlike PM2.5, UFPs may have much more impacts on human health considering loads of evidences emerging from particulate matters and nanotoxicology research fields. The knowledge of nanotoxicology contributes to the understanding of toxicity mechanisms of airborne UFPs in air pollution. This article is part of a Special Issue entitled Air Pollution, edited by Wenjun Ding, Andrew J. Ghio and Weidong Wu. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Ultrafine particles and black carbon personal exposures in asthmatic and non-asthmatic children at school age.

    PubMed

    Pañella, P; Casas, M; Donaire-Gonzalez, D; Garcia-Esteban, R; Robinson, O; Valentín, A; Gulliver, J; Momas, I; Nieuwenhuijsen, M; Vrijheid, M; Sunyer, J

    2017-09-01

    Traffic-related air pollution (TRAP) exposure during childhood is associated with asthma; however, the contribution of the different TRAP pollutants in each microenvironment (home, school, transportation, others) in asthmatic and non-asthmatic children is unknown. Daily (24-h) personal black carbon (BC), ultrafine particle (UFP), and alveolar lung-deposited surface area (LDSA) individual exposure measurements were obtained from 100 children (29 past and 21 current asthmatics, 50 non-asthmatics) aged 9±0.7 years from the INMA-Sabadell cohort (Catalonia, Spain). Time spent in each microenvironment was derived by the geolocation provided by the smartphone and a new spatiotemporal map-matching algorithm. Asthmatics and non-asthmatics spent the same amount of time at home (60% and 61%, respectively), at school (20% and 23%), on transportation (8% and 7%), and in other microenvironments (7% and 5%). The highest concentrations of all TRAPs were attributed to transportation. No differences in TRAP concentrations were found overall or by type of microenvironment between asthmatics and non-asthmatics, nor when considering past and current asthmatics, separately. In conclusion, asthmatic and non-asthmatic children had a similar time-activity pattern and similar average exposures to BC, UFP, and LDSA concentrations. This suggests that interventions should be tailored to general population, rather than to subgroups defined by disease. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. In-vehicle exposures to particulate air pollution in Canadian metropolitan areas: the urban transportation exposure study.

    PubMed

    Weichenthal, Scott; Van Ryswyk, Keith; Kulka, Ryan; Sun, Liu; Wallace, Lance; Joseph, Lawrence

    2015-01-06

    Commuters may be exposed to increased levels of traffic-related air pollution owing to close proximity to traffic-emissions. We collected in-vehicle and roof-top air pollution measurements over 238 commutes in Montreal, Toronto, and Vancouver, Canada between 2010 and 2013. Voice recordings were used to collect real-time information on traffic density and the presence of diesel vehicles and multivariable linear regression models were used to estimate the impact of these factors on in-vehicle pollutant concentrations (and indoor/outdoor ratios) along with parameters for road type, land use, and meteorology. In-vehicle PM2.5 and NO2 concentrations consistently exceeded regional outdoor levels and each unit increase in the rate of encountering diesel vehicles (count/min) was associated with substantial increases (>100%) in in-vehicle concentrations of ultrafine particles (UFPs), black carbon, and PM2.5 as well as strong increases (>15%) in indoor/outdoor ratios. A model based on meteorology and the length of highway roads within a 500 m buffer explained 53% of the variation in in-vehicle UFPs; however, models for PM2.5 (R(2) = 0.24) and black carbon (R(2) = 0.30) did not perform as well. Our findings suggest that vehicle commuters experience increased exposure to air pollutants and that traffic characteristics, land use, road types, and meteorology are important determinants of these exposures.

  1. Turbulent Size Selection and Concentration of Chondrule-Sized Objects: Reynolds Number Invariance and Implications

    NASA Technical Reports Server (NTRS)

    Cuzzi, J. N.; Hogan, R.; Dobrovolskis, A.; Paque, J.

    2006-01-01

    size depends primarily on the intensity of the turbulent kinetic energy (represented by the Reynolds number of the nebula). Specifically, the preferentially concentrated particle is that which has a stopping time equal to the turnover time of the smallest eddy. The intensity level of turbulence implied by chondrule sizes can be maintained by even a small fraction of the energy released by the radially evolving disk (it must be noted that the details of how this transfer of energy actually occurs remain obscure, however).

  2. Inhalation of ultrafine carbon particles alters heart rate and heart rate variability in people with type 2 diabetes.

    PubMed

    Vora, Rathin; Zareba, Wojciech; Utell, Mark J; Pietropaoli, Anthony P; Chalupa, David; Little, Erika L; Oakes, David; Bausch, Jan; Wiltshire, Jelani; Frampton, Mark W

    2014-07-16

    Diabetes may confer an increased risk for the cardiovascular health effects of particulate air pollution, but few human clinical studies of air pollution have included people with diabetes. Ultrafine particles (UFP, ≤100 nm in diameter) have been hypothesized to be an important component of particulate air pollution with regard to cardiovascular health effects. 17 never-smoker subjects 30-60 years of age, with stable type 2 diabetes but otherwise healthy, inhaled either filtered air (0-10 particles/cm3) or elemental carbon UFP (~107 particles/cm3, ~50 ug/m3, count median diameter 32 nm) by mouthpiece, for 2 hours at rest, in a double-blind, randomized, crossover study design. A digital 12-lead electrocardiogram (ECG) was recorded continuously for 48 hours, beginning 1 hour prior to exposure. Analysis of 5-minute segments of the ECG during quiet rest showed reduced high-frequency heart rate variability with UFP relative to air exposure (p = 0.014), paralleled by non-significant reductions in time-domain heart rate variability parameters. In the analysis of longer durations of the ECG, we found that UFP exposure increased the heart rate relative to air exposure. During the 21- to 45-hour interval after exposure, the average heart rate increased approximately 8 beats per minute with UFP, compared to 5 beats per minute with air (p = 0.045). There were no UFP effects on cardiac rhythm or repolarization. Inhalation of elemental carbon ultrafine particles alters heart rate and heart rate variability in people with type 2 diabetes. Our findings suggest that effects may occur and persist hours after a single 2-hour exposure.

  3. Interaction of ozone with wooden building products, treated wood samples and exotic wood species

    NASA Astrophysics Data System (ADS)

    Schripp, Tobias; Langer, Sarka; Salthammer, Tunga

    2012-07-01

    Wooden building products indoors are known to be able to affect the perceived air quality depending on their emission strength. The indoor application of modern ecological lacquer systems (eco-lacquers or 'green' lacquers) may be a much stronger source than the substrates itself. Especially with regard to the formation of ultrafine particles by gas-to-particle conversion in the presence of ozone or other reactive species the impact of the applied building products on the indoor air quality has to be addressed. The present study reports a two concentration step ozonation of OSB panels, painted beech boards, and a number of solid 'exotic' wood types in a 1 m³ emission test chamber. The emission of volatile organic compounds (VOC) was recorded as well as the formation of ultrafine particles in the range 7-300 nm. The products are characterized on the basis of their ozone deposition velocity; the obtained values of 0.008-0.381 cm s-1 are comparable with previously published data. Within the samples of the present study one eco-lacquer was the strongest source of VOC (total VOC ˜ 60 mg m-3) while the wooden building products (OSB) were of intermediate emission strength. The lowest emission was found for the solid (exotic) wood samples. The VOC release of the samples corresponded roughly to the particle formation potential. However, the strongest UFP formation was measured for one solid wood sample ('Garapa') which showed a strong surface reaction in the presence of ozone and formed a large number of particles <40 nm. Overall, the experiments demonstrated the necessity of real-life samples for the estimation of UFP indoor air pollution from the ozone chemistry of terpenes.

  4. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Global Research has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GE Global Research (prime contractor) wasmore » awarded a contract from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GE Global Research, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal and air are simultaneously converted into separate streams of (1) high-purity hydrogen that can be utilized in fuel cells or turbines, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure vitiated air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on ASPEN Plus process modeling, has an estimated process efficiency of 6 percentage points higher than IGCC with conventional CO{sub 2} separation. The current R&D program will determine the feasibility of the integrated UFP technology through pilot-scale testing, and will investigate operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates experimental testing, modeling and economic studies to demonstrate the UFP technology. This is the fourteenth quarterly technical progress report for the UFP

  5. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Global Research (GEGR) has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GEGR (prime contractor) was awardedmore » a contract from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GEGR, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal and air are simultaneously converted into separate streams of (1) high-purity hydrogen that can be utilized in fuel cells or turbines, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure vitiated air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on Aspen Plus process modeling, has an estimated process efficiency of 6% higher than IGCC with conventional CO{sub 2} separation. The current R&D program will determine the feasibility of the integrated UFP technology through pilot-scale testing, and will investigate operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates experimental testing, modeling and economic studies to demonstrate the UFP technology. This is the third annual technical progress report for the UFP program supported by U.S. DOE NETL (Contract No

  6. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Global Research has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GE Global Research (prime contractor) wasmore » awarded a contract from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GE Global Research, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal and air are simultaneously converted into separate streams of (1) high-purity hydrogen that can be utilized in fuel cells or turbines, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure vitiated air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on ASPEN Plus process modeling, has an estimated process efficiency of 6% higher than IGCC with conventional CO{sub 2} separation. The current R&D program will determine the feasibility of the integrated UFP technology through pilot-scale testing, and will investigate operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates experimental testing, modeling and economic studies to demonstrate the UFP technology. This is the thirteenth quarterly technical progress report for the UFP program, which is

  7. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Global Research has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GE Global Research (prime contractor) wasmore » awarded a contract from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GE Global Research, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal and air are simultaneously converted into separate streams of (1) high-purity hydrogen that can be utilized in fuel cells or turbines, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure vitiated air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on ASPEN Plus process modeling, has an estimated process efficiency of 6 percentage points higher than IGCC with conventional CO{sub 2} separation. The current R&D program has determined the feasibility of the integrated UFP technology through pilot-scale testing, and investigated operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrated experimental testing, modeling and economic studies to demonstrate the UFP technology. This is the fifteenth quarterly technical progress report for the UFP program

  8. Linking particle number concentration (PNC), meteorology and traffic variables in a UK street canyon

    NASA Astrophysics Data System (ADS)

    Price, Heather D.; Arthur, Robert; BéruBé, Kelly A.; Jones, Tim P.

    2014-10-01

    Ambient particle number concentration (PNC) has been linked with adverse health outcomes such as asthma, reduced lung function and cardiovascular disease. To investigate the relationship between PNC, meteorology and traffic we measured size segregated respirable particles in a busy commuter street in Swansea, UK for ten months using a Dekati Electrical Low Pressure Impactor (ELPI). The ELPI segregates particles into 12 size fractions between 7 nm and 10 μm. The median PNC for the sampling period was 31,545 cm- 3. For the ultrafine particles (7-93 nm), the highest PNC was found in winter (46,615 cm- 3; 15 minute average) and the lowest for that size fraction in summer (29,696 cm- 3). For the particles below 93 nm there was a trimodal distribution to weekdays (particularly Monday to Wednesday), with PNC peaks at 09:00, 16:00 and 23:00. Wind direction had a significant influence on PNC and differed between particles in the fine range (below 2.5 μm) and more coarse particles (up to 10 μm). For fine particles, winds parallel to the canyon were associated with higher PNCs which were attributed to the replenishment of traffic particles. For coarse particles, PNCs were higher from winds perpendicular to the canyon and this was linked to source distribution around the sampling site and the recirculation of pollutants within the canyon. During times when vehicle volumes were high and vehicles were exhibiting stop-start behaviour, if this was combined with low wind speeds, ultrafine PNC was highest. This effect was generally observed during the morning rush hour. Current mass-based legislation does not take into account exposure to the number of particles or the change in population exposure diurnally.

  9. Sensible and Crazy Numbers

    ERIC Educational Resources Information Center

    Russo, James

    2017-01-01

    Using a game-based context and concentrating explicitly on language, students in the early years are able to make sense about place value amid the vagaries of the English language in naming numbers. This conceptual approach to understanding place value allows students to further develop number strategies beyond counting by ones.

  10. Impact of new particle formation on the concentrations of aerosol number and cloud condensation nuclei around Beijing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsui, H.; Koike, Makoto; Kondo, Yutaka

    New particle formation (NPF) is one of the most important processes in controlling the concentrations of aerosol number (condensation nuclei, CN) and cloud condensation nuclei (CCN) in the atmosphere. In this study, we introduced a new aerosol model representation with 20 size bins between 1 nm and 10 {mu}m and activation-type and kinetic nucleation parameterizations into the WRF-chem model (called NPF-explicit WRF-chem). Model calculations were conducted in the Beijing region in China for the periods during the CARE-Beijing 2006 campaign conducted in August and September 2006. Model calculations successfully reproduced the timing of NPF and no-NPF days in the measurementsmore » (21 of 26 days). Model calculations also reproduced the subsequent rapid growth of new particles with a time scale of half a day. These results suggest that once a reasonable nucleation rate at a diameter of 1 nm is given, explicit calculations of condensation and coagulation processes can reproduce the clear contrast between NPF and no-NPF days as well as further growth up to several tens nanometers. With this reasonable representation of the NPF process, we show that NPF contributed 20-30% of CN concentrations (> 10 nm in diameter) in and around Beijing on average. We also show that NPF increases CCN concentrations at higher supersaturations (S > 0.2%), while it decreases them at lower supersaturations (S < 0.1%). This is likely because NPF suppresses the increases in both the size and hygroscopicity of pre-existing particles through the competition of condensable gases between new particles and pre-existing particles. Sensitivity calculations show that a reduction of primary aerosol emissions, such as black carbon (BC), would not necessarily decrease CCN concentrations because of an increase in NPF. Sensitivity calculations also suggest that the reduction ratio of primary aerosol and SO2 emissions will be key in enhancing or damping the BC mitigation effect.« less

  11. Ambient Ultrafine Particle Ingestion Alters Gut Microbiota in Association with Increased Atherogenic Lipid Metabolites

    PubMed Central

    Li, Rongsong; Yang, Jieping; Saffari, Arian; Jacobs, Jonathan; Baek, Kyung In; Hough, Greg; Larauche, Muriel H.; Ma, Jianguo; Jen, Nelson; Moussaoui, Nabila; Zhou, Bill; Kang, Hanul; Reddy, Srinivasa; Henning, Susanne M.; Campen, Matthew J.; Pisegna, Joseph; Li, Zhaoping; Fogelman, Alan M.; Sioutas, Constantinos; Navab, Mohamad; Hsiai, Tzung K.

    2017-01-01

    Ambient particulate matter (PM) exposure is associated with atherosclerosis and inflammatory bowel disease. Ultrafine particles (UFP, dp < 0.1–0.2 μm) are redox active components of PM. We hypothesized that orally ingested UFP promoted atherogenic lipid metabolites in both the intestine and plasma via altered gut microbiota composition. Low density lipoprotein receptor-null (Ldlr−/−) mice on a high-fat diet were orally administered with vehicle control or UFP (40 μg/mouse/day) for 3 days a week. After 10 weeks, UFP ingested mice developed macrophage and neutrophil infiltration in the intestinal villi, accompanied by elevated cholesterol but reduced coprostanol levels in the cecum, as well as elevated atherogenic lysophosphatidylcholine (LPC 18:1) and lysophosphatidic acids (LPAs) in the intestine and plasma. At the phylum level, Principle Component Analysis revealed significant segregation of microbiota compositions which was validated by Beta diversity analysis. UFP-exposed mice developed increased abundance in Verrocomicrobia but decreased Actinobacteria, Cyanobacteria, and Firmicutes as well as a reduced diversity in microbiome. Spearman’s analysis negatively correlated Actinobacteria with cecal cholesterol, intestinal and plasma LPC18:1, and Firmicutes and Cyanobacteria with plasma LPC 18:1. Thus, ultrafine particles ingestion alters gut microbiota composition, accompanied by increased atherogenic lipid metabolites. These findings implicate the gut-vascular axis in a atherosclerosis model. PMID:28211537

  12. 3D Printing. What's the Harm?

    ERIC Educational Resources Information Center

    Love, Tyler S.; Roy, Ken

    2016-01-01

    Health concerns from 3D printing were first documented by Stephens, Azimi, Orch, and Ramos (2013), who found that commercially available 3D printers were producing hazardous levels of ultrafine particles (UFPs) and volatile organic compounds (VOCs) when plastic materials were melted through the extruder. UFPs are particles less than 100 nanometers…

  13. Investigating the Relative Contributions of Secondary Ice Formation Processes to Ice Crystal Number Concentrations Within Mixed-Phase Clouds

    NASA Astrophysics Data System (ADS)

    Sullivan, S.; Nenes, A.

    2015-12-01

    Measurements of the in-cloud ice nuclei concentration can be three or four orders of magnitude less than those of the in-cloud ice crystal number concentration. Different secondary formation processes, active after initial ice nucleation, have been proposed to explain this discrepancy, but their relative importance, and even the exact physics of each mechanism, are still unclear. We construct a simple bin microphysics model (2IM) including depositional growth, the Hallett-Mossop process, ice-ice collisions, and ice-ice aggregation, with temperature- and supersaturation-dependent efficiencies for each process. 2IM extends the time-lag collision model of Yano and Phillips to additional bins and incorporates the aspect ratio evolution of Jensen and Harrington. Model output and measured ice crystal size distributions are compared to answer three questions: (1) how important is ice-ice aggregation relative to ice-ice collision around -15°C, where the Hallett-Mossop process is no longer active; (2) what process efficiencies lead to the best reproduction of observed ice crystal size distributions; and (3) does ice crystal aspect ratio affect the dominant secondary formation process. The resulting parameterization is intended for eventual use in larger-scale mixed-phase cloud schemes.

  14. Physico-chemical properties and biological effects of diesel and biomass particles.

    PubMed

    Longhin, Eleonora; Gualtieri, Maurizio; Capasso, Laura; Bengalli, Rossella; Mollerup, Steen; Holme, Jørn A; Øvrevik, Johan; Casadei, Simone; Di Benedetto, Cristiano; Parenti, Paolo; Camatini, Marina

    2016-08-01

    Diesel combustion and solid biomass burning are the major sources of ultrafine particles (UFP) in urbanized areas. Cardiovascular and pulmonary diseases, including lung cancer, are possible outcomes of combustion particles exposure, but differences in particles properties seem to influence their biological effects. Here the physico-chemical properties and biological effects of diesel and biomass particles, produced under controlled laboratory conditions, have been characterized. Diesel UFP were sampled from a Euro 4 light duty vehicle without DPF fuelled by commercial diesel and run over a chassis dyno. Biomass UFP were collected from a modern automatic 25 kW boiler propelled by prime quality spruce pellet. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) images of both diesel and biomass samples showed aggregates of soot particles, but in biomass samples ash particles were also present. Chemical characterization showed that metals and PAHs total content was higher in diesel samples compared to biomass ones. Human bronchial epithelial (HBEC3) cells were exposed to particles for up to 2 weeks. Changes in the expression of genes involved in xenobiotic metabolism were observed after exposure to both UFP already after 24 h. However, only diesel particles modulated the expression of genes involved in inflammation, oxidative stress and epithelial-to-mesenchymal transition (EMT), increased the release of inflammatory mediators and caused phenotypical alterations, mostly after two weeks of exposure. These results show that diesel UFP affected cellular processes involved in lung and cardiovascular diseases and cancer. Biomass particles exerted low biological activity compared to diesel UFP. This evidence emphasizes that the study of different emission sources contribution to ambient PM toxicity may have a fundamental role in the development of more effective strategies for air quality improvement. Copyright © 2016 Elsevier Ltd. All rights

  15. Zone of influence for particle number concentrations at signalised traffic intersections

    NASA Astrophysics Data System (ADS)

    Goel, Anju; Kumar, Prashant

    2015-12-01

    Estimation of zone of influences (ZoI) at signalised traffic intersections (TI) is important to accurately model particle number concentrations (PNCs) and their exposure to public at emission hotspot locations. However, estimates of ZoI for PNCs at different types of TIs are barely known. We carried out mobile measurements inside the car cabin with windows fully open for size-resolved PNCs in the 5-560 nm range on a 6 km long busy round route that had 10 TIs. These included four-way TIs without built-up area (TI4w-nb), four-way TIs with built-up area (TI4w-wb), three-way TIs without built-up area (TI3w-nb) and three-way TIs with built-up area (TI3w-wb). Mobile measurements were made with a fast response differential mobility spectrometer (DMS50). Driving speed and position of the car were recorded every second using a global positioning system (GPS). Positive matrix factorisation (PMF) modelling was applied on the data to quantify the contribution of PNCs released during deceleration, creep-idling, acceleration and cruising to total PNCs at the TIs. The objectives were to address the following questions: (i) how does ZoI vary at different types of TIs in stop- and go-driving conditions?, (ii) what is the effect of different driving conditions on ZoI of a TI?, (iii) how realistically can the PNC profiles be generalised within a ZoI of a TI?, and (iv) what is the share of emissions during different driving conditions towards the total PNCs at a TI? Average length of ZoI in longitudinal direction and along the road was found to be the highest (148 m; 89 to -59 m from the centre of a TI) at a TI3w-wb, followed by TI4w-nb (129 m; 79 to -42 m), TI3w-nb (86 m; 71 to -15 m) and TI4w-wb (79 m; 46 to -33 m) in stop- and go-driving conditions. During multiple stopping driving conditions when a vehicle stops at a TI more than once in a signal cycle due to oversaturation of vehicles, average length of ZoI increased by 55, 22 and 21% at TI4w-nb, TI3w-nb and TI3w-wb, respectively

  16. Using satellite-based measurements to explore ...

    EPA Pesticide Factsheets

    New particle formation (NPF) can potentially alter regional climate by increasing aerosol particle (hereafter particle) number concentrations and ultimately cloud condensation nuclei. The large scales on which NPF is manifest indicate potential to use satellite-based (inherently spatially averaged) measurements of atmospheric conditions to diagnose the occurrence of NPF and NPF characteristics. We demonstrate the potential for using satellite-measurements of insolation (UV), trace gas concentrations (sulfur dioxide (SO2), nitrogen dioxide (NO2), ammonia (NH3), formaldehyde (HCHO), ozone (O3)), aerosol optical properties (aerosol optical depth (AOD), Ångström exponent (AE)), and a proxy of biogenic volatile organic compound emissions (leaf area index (LAI), temperature (T)) as predictors for NPF characteristics: formation rates, growth rates, survival probabilities, and ultrafine particle (UFP) concentrations at five locations across North America. NPF at all sites is most frequent in spring, exhibits a one-day autocorrelation, and is associated with low condensational sink (AOD×AE) and HCHO concentrations, and high UV. However, there are important site-to-site variations in NPF frequency and characteristics, and in which of the predictor variables (particularly gas concentrations) significantly contribute to the explanatory power of regression models built to predict those characteristics. This finding may provide a partial explanation for the reported spatia

  17. Airborne agent concentration analysis

    DOEpatents

    Gelbard, Fred

    2004-02-03

    A method and system for inferring airborne contaminant concentrations in rooms without contaminant sensors, based on data collected by contaminant sensors in other rooms of a building, using known airflow interconnectivity data. The method solves a least squares problem that minimizes the difference between measured and predicted contaminant sensor concentrations with respect to an unknown contaminant release time. Solutions are constrained to providing non-negative initial contaminant concentrations in all rooms. The method can be used to identify a near-optimal distribution of sensors within the building, when then number of available sensors is less than the total number of rooms. This is achieved by having a system-sensor matrix that is non-singular, and by selecting that distribution which yields the lowest condition number of all the distributions considered. The method can predict one or more contaminant initial release points from the collected data.

  18. Ultrafine particles, and PM 2.5 generated from cooking in homes

    NASA Astrophysics Data System (ADS)

    Wan, Man-Pun; Wu, Chi-Li; Sze To, Gin-Nam; Chan, Tsz-Chun; Chao, Christopher Y. H.

    2011-11-01

    Exposure to airborne particulate matters (PM) emitted during cooking can lead to adverse health effects. An understanding of the exposure to PM during cooking at home provides a foundation for the quantification of possible health risks. The concentrations of airborne particles covering the ultrafine (14.6-100 nm) and accumulation mode (100-661.2 nm) size ranges and PM 2.5 (airborne particulate matters smaller than 2.5 μm in diameter) during and after cooking activities were measured in 12 naturally ventilated, non-smoking homes in Hong Kong, covering a total of 33 cooking episodes. The monitored homes all practiced Chinese-style cooking. Cooking elevated the average number concentrations of ultrafine particles (UFPs) and accumulation mode particles (AMPs) by 10 fold from the background level in the living room and by 20-40 fold in the kitchen. PM 2.5 mass concentrations went up to the maximum average of about 160 μg m -3 in the kitchen and about 60 μg m -3 in the living room. Cooking emitted particles dispersed quickly from the kitchen to the living room indicating that the health impact is not limited to occupants in the kitchen. Particle number and mass concentrations remained elevated for 90 min in the kitchen and for 60 min in the living room after cooking. Particles in cooking emissions were mainly in the ultrafine size range in terms of the number count while AMPs contributed to at least 60% of the surface area concentrations in the kitchen and 73% in the living room. This suggests that AMPs could still be a major health concern since the particle surface area concentration is suggested to have a more direct relationship with inhalation toxicity than with number concentration. Particle number concentration (14.6-661.2 nm) in the living room was about 2.7 times that in the outdoor environment, suggesting that better ventilation could help reduce exposure.

  19. Effects of SULT1A1 Copy Number Variation on Estrogen Concentration and Tamoxifen-Associated Adverse Drug Reactions in Premenopausal Thai Breast Cancer Patients: A Preliminary Study.

    PubMed

    Charoenchokthavee, Wanaporn; Ayudhya, Duangchit Panomvana Na; Sriuranpong, Virote; Areepium, Nutthada

    2016-01-01

    Tamoxifen is a pharmacological estrogen inhibitor that binds to the estrogen receptor (ER) in breast cells. However, it shows an estrogenic effect in other organs, which causes adverse drug reactions (ADRs). The sulfotransferase 1A1 (SULT1A1) enzyme encoded by the SULT1A1 gene is involved in estrogen metabolism. Previous research has suggested that the SULT1A1 copy number is linked with the plasma estradiol (E2) concentration. Here, a total of 34 premenopausal breast cancer patients, selected from the Thai Tamoxifen (TTAM) Project, were screened for their SULT1A1 copy number, plasma E2 concentration and ADRs. The mean age was 44.3±11.1 years, and they were subtyped as ER+/ progesterone receptor (PR) + (28 patients), ER+/ PR- (5 patients) and ER-/PR- (1 patient). Three patients reported ADRs, which were irregular menstruation (2 patients) and vaginal discharge (1 patient). Most (33) patients had two SULT1A1 copies, with one patient having three copies. The median plasma E2 concentration was 1,575.6 (IQR 865.4) pg/ml. Patients with ADRs had significantly higher plasma E2 concentrations than those patients without ADRs (p = 0.014). The plasma E2 concentration was numerically higher in the patient with three SULT1A1 copies, but this lacked statistical significance.

  20. Air quality impacts of a CicLAvia event in Downtown Los Angeles, CA.

    PubMed

    Shu, Shi; Batteate, Christina; Cole, Brian; Froines, John; Zhu, Yifang

    2016-01-01

    CicLAvia in Los Angeles, CA is the open streets program that closes streets to motorized vehicles and invites people to walk, run, play or ride their bicycles on these streets, allowing them to experience the city in a new way and get exercise at the same time. Since the events reduce the motorized traffic flow, which is a significant source of air pollution, on the streets, it is reasonable to hypothesize that the CicLAvia events can reduce the concentrations of traffic-emitted air pollutants during the road closure. This study is the first experiment to test this hypothesis. The on-road and community-wide ultrafine particle (UFP) and PM2.5 were measured on the Event-Sunday (October 5th, 2014) and the Pre- and Post- Sundays (September 28(th) and October 12(th), 2014). Data analysis results showed the on-road UFP and PM2.5 reduction was 21% and 49%, respectively, and the community-wide PM2.5 reduction was 12%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Determination of the vertical profile of particle number concentration adjacent to a motorway using an unmanned aerial vehicle.

    PubMed

    Villa, T F; Jayaratne, E R; Gonzalez, L F; Morawska, L

    2017-11-01

    A quantitative assessment of the vertical profile of traffic pollution, specifically particle number concentration (PNC), in an open space adjacent to a motorway was possible for the first time, to the knowledge of the authors, using an Unmanned Aerial Vehicle (UAV) system. Until now, traffic pollution has only been measured at ground level while the vertical distribution, is limited to studies conducted from buildings or fixed towers and balloons. This new UAV system demonstrated that the PNC sampled during the period form 10 a.m. to 4 p.m., outside the rush hours with a constant traffic flow, increased from a concentration of 2 × 10 4 p/cm 3 near the ground up to 10 m, and then sharply decreased attaining a steady value of 4 × 10 3 p/cm 3 beyond a height of about 40 m. While more comprehensive investigations would be warranted under different conditions, such as topography and vehicle and fuel type, this finding is of great significance, given that it demonstrates the impact of traffic emissions on human exposure, but less so to pollution within the upper part of the boundary layer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Characterisation of particle mass and number concentration on the east coast of the Malaysian Peninsula during the northeast monsoon

    NASA Astrophysics Data System (ADS)

    Dominick, Doreena; Latif, Mohd Talib; Juneng, Liew; Khan, Md Firoz; Amil, Norhaniza; Mead, Mohammed Iqbal; Nadzir, Mohd Shahrul Mohd; Moi, Phang Siew; Samah, Azizan Abu; Ashfold, Matthew J.; Sturges, William T.; Harris, Neil R. P.; Robinson, Andrew D.; Pyle, John A.

    2015-09-01

    Particle mass concentrations (PM10, PM2.5 and PM1) and particle number concentration ((PNC); 0.27 μm ≤ Dp ≤ 34.00 μm) were measured in the tropical coastal environment of Bachok, Kelantan on the Malaysian Peninsula bordering the southern edge of the South China Sea. Statistical methods were applied on a three-month hourly data set (9th January to 24th March 2014) to study the influence of north-easterly winds on the patterns of particle mass and PNC size distributions. The 24-h concentrations of particle mass obtained in this study were below the standard values detailed by the Recommended Malaysian Air Quality Guideline (RMAQG), United States Environmental Protection Agency (US EPA) and European Union (EU) except for PM2.5, which recorded a 24-h average of 30 ± 18 μg m-3 and exceeded the World Health Organisation (WHO) threshold value (25 μg m-3). Principal component analysis (PCA) revealed that PNC with smaller diameter sizes (0.27-4.50 μm) showed a stronger influence, accounting for 57.6% of the variability in PNC data set. Concentrations of both particle mass and PNC increased steadily in the morning with a distinct peak observed at around 8.00 h, related to a combination of dispersion of accumulated particles overnight and local traffic. In addition to local anthropogenic, agricultural burning and forest fire activities, long-range transport also affects the study area. Hotspot and backward wind trajectory observations illustrated that the biomass burning episode (around February-March) significantly influenced PNC. Meteorological parameters influenced smaller size particles (i.e. PM1 and Dp (0.27-0.43 μm)) the most.

  3. Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air.

    PubMed

    Guo, Hai; Morawska, Lidia; He, Congrong; Zhang, Yanli L; Ayoko, Godwin; Cao, Min

    2010-07-01

    The impact of air pollution on school children's health is currently one of the key foci of international and national agencies. Of particular concern are ultrafine particles which are emitted in large quantities, contain large concentrations of toxins and are deposited deeply in the respiratory tract. In this study, an intensive sampling campaign of indoor and outdoor airborne particulate matter was carried out in a primary school in February 2006 to investigate indoor and outdoor particle number (PN) and mass concentrations (PM(2.5)), and particle size distribution, and to evaluate the influence of outdoor air pollution on the indoor air. For outdoor PN and PM(2.5), early morning and late afternoon peaks were observed on weekdays, which are consistent with traffic rush hours, indicating the predominant effect of vehicular emissions. However, the temporal variations of outdoor PM(2.5) and PN concentrations occasionally showed extremely high peaks, mainly due to human activities such as cigarette smoking and the operation of mower near the sampling site. The indoor PM(2.5) level was mainly affected by the outdoor PM(2.5) (r = 0.68, p < 0.01), whereas the indoor PN concentration had some association with outdoor PN values (r = 0.66, p < 0.01) even though the indoor PN concentration was occasionally influenced by indoor sources, such as cooking, cleaning and floor polishing activities. Correlation analysis indicated that the outdoor PM(2.5) was inversely correlated with the indoor to outdoor PM(2.5) ratio (I/O ratio; r = -0.49, p < 0.01), while the indoor PN had a weak correlation with the I/O ratio for PN (r = 0.34, p < 0.01). The results showed that occupancy did not cause any major changes to the modal structure of particle number and size distribution, even though the I/O ratio was different for different size classes. The I/O curves had a maximum value for particles with diameters of 100-400 nm under both occupied and unoccupied scenarios, whereas no significant

  4. Particulate Emissions from a Stationary Engine Fueled with Ultra-Low-Sulfur Diesel and Waste-Cooking-Oil-Derived Biodiesel.

    PubMed

    Betha, Raghu; Balasubramanian, Rajasekhar

    2011-10-01

    Stationary diesel engines, especially diesel generators, are increasingly being used in both developing countries and developed countries because of increased power demand. Emissions from such engines can have adverse effects on the environment and public health. In this study, particulate emissions from a domestic stationary diesel generator running on ultra-low-sulfur diesel (ULSD) and biodiesel derived from waste cooking oil were characterized for different load conditions. Results indicated a reduction in particulate matter (PM) mass and number emissions while switching diesel to biodiesel. With increase in engine load, it was observed that particle mass increased, although total particle counts decreased for all the fuels. The reduction in total number concentration at higher loads was, however, dependent on percentage of biodiesel in the diesel-biodiesel blend. For pure biodiesel (B100), the reduction in PM emissions for full load compared to idle mode was around 9%, whereas for ULSD the reduction was 26%. A large fraction of ultrafine particles (UFPs) was found in the emissions from biodiesel compared to ULSD. Nearly 90% of total particle concentration in biodiesel emissions comprised ultrafine particles. Particle peak diameter shifted from a smaller to a lower diameter with increase in biodiesel percentage in the fuel mixture. [Box: see text].

  5. Particulate emissions from a stationary engine fueled with ultra-low-sulfur diesel and waste-cooking-oil-derived biodiesel.

    PubMed

    Betha, Raghu; Balasubramanian, Rajasekhar

    2011-10-01

    Stationary diesel engines, especially diesel generators, are increasingly being used in both developing countries and developed countries because of increased power demand. Emissions from such engines can have adverse effects on the environment and public health. In this study, particulate emissions from a domestic stationary diesel generator running on ultra-low-sulfur diesel (ULSD) and biodiesel derived from waste cooking oil were characterized for different load conditions. Results indicated a reduction in particulate matter (PM) mass and number emissions while switching diesel to biodiesel. With increase in engine load, it was observed that particle mass increased, although total particle counts decreased for all the fuels. The reduction in total number concentration at higher loads was, however, dependent on percentage of biodiesel in the diesel-biodiesel blend. For pure biodiesel (B100), the reduction in PM emissions for full load compared to idle mode was around 9%, whereas for ULSD the reduction was 26%. A large fraction of ultrafine particles (UFPs) was found in the emissions from biodiesel compared to ULSD. Nearly 90% of total particle concentration in biodiesel emissions comprised ultrafine particles. Particle peak diameter shifted from a smaller to a lower diameter with increase in biodiesel percentage in the fuel mixture.

  6. Comparison of air pollution exposures in active vs. passive travel modes in European cities: A quantitative review.

    PubMed

    de Nazelle, Audrey; Bode, Olivier; Orjuela, Juan Pablo

    2017-02-01

    Transport microenvironments tend to have higher air pollutant concentrations than other settings most people encounter in their daily lives. The choice of travel modes may affect significantly individuals' exposures; however such considerations are typically not accounted for in exposure assessment used in environmental health studies. In particular, with increasing interest in the promotion of active travel, health impact studies that attempt to estimate potential adverse consequences of potential increased pollutant inhalation during walking or cycling have emerged. Such studies require a quantification of relative exposures in travel modes. The literature on air pollution exposures in travel microenvironments in Europe was reviewed. Studies which measured various travel modes including at least walking or cycling in a simultaneous or quasi-simultaneous design were selected. Data from these studies were harmonized to allow for a quantitative synthesis of the estimates. Ranges of ratios and 95% confidence interval (CI) of air pollution exposure between modes and between background and transportation modes were estimated. Ten studies measuring fine particulate matter (PM 2.5 ), black carbon (BC), ultrafine particles (UFP), and/or carbon monoxide (CO) in the walk, bicycle, car and/or bus modes were included in the analysis. Only three reported on CO and BC and results should be interpreted with caution. Pedestrians were shown to be the most consistently least exposed of all across studies, with the bus, bicycle and car modes on average 1.3 to 1.5 times higher for PM 2.5 ; 1.1 to 1.7 times higher for UFP; and 1.3 to 2.9 times higher for CO; however the 95% CI included 1 for the UFP walk to bus ratio. Only for BC were pedestrians more exposed than bus users on average (bus to walk ratio 0.8), but remained less exposed than those on bicycles or in cars. Car users tended to be the most exposed (from 2.9 times higher than pedestrians for BC down to similar exposures to

  7. Horizontally staggered lightguide solar concentrator with lateral displacement tracking for high concentration applications.

    PubMed

    Ma, Hongcai; Wu, Lin

    2015-07-10

    We present the design of a horizontally staggered lightguide solar concentrator with lateral displacement tracking for high concentration applications. This solar concentrator consists of an array of telecentric primary concentrators, a horizontally staggered lightguide layer, and a vertically tapered lightguide layer. The primary concentrator is realized by two plano-aspheric lenses with lateral movement and maintains a high F-number over an angle range of ±23.5°. The results of the simulations show that the solar concentrator achieves a high concentration ratio of 500× with ±0.5° of acceptance angle by a single-axis tracker and dual lateral translation stages.

  8. Design of a New Concentration Series for the Orthogonal Sample Design Approach and Estimation of the Number of Reactions in Chemical Systems.

    PubMed

    Shi, Jiajia; Liu, Yuhai; Guo, Ran; Li, Xiaopei; He, Anqi; Gao, Yunlong; Wei, Yongju; Liu, Cuige; Zhao, Ying; Xu, Yizhuang; Noda, Isao; Wu, Jinguang

    2015-11-01

    A new concentration series is proposed for the construction of a two-dimensional (2D) synchronous spectrum for orthogonal sample design analysis to probe intermolecular interaction between solutes dissolved in the same solutions. The obtained 2D synchronous spectrum possesses the following two properties: (1) cross peaks in the 2D synchronous spectra can be used to reflect intermolecular interaction reliably, since interference portions that have nothing to do with intermolecular interaction are completely removed, and (2) the two-dimensional synchronous spectrum produced can effectively avoid accidental collinearity. Hence, the correct number of nonzero eigenvalues can be obtained so that the number of chemical reactions can be estimated. In a real chemical system, noise present in one-dimensional spectra may also produce nonzero eigenvalues. To get the correct number of chemical reactions, we classified nonzero eigenvalues into significant nonzero eigenvalues and insignificant nonzero eigenvalues. Significant nonzero eigenvalues can be identified by inspecting the pattern of the corresponding eigenvector with help of the Durbin-Watson statistic. As a result, the correct number of chemical reactions can be obtained from significant nonzero eigenvalues. This approach provides a solid basis to obtain insight into subtle spectral variations caused by intermolecular interaction.

  9. Concentration of Swiss Elite Orienteers.

    ERIC Educational Resources Information Center

    Seiler, Roland; Wetzel, Jorg

    1997-01-01

    A visual discrimination task was used to measure concentration among 43 members of Swiss national orienteering teams. Subjects were above average in the number of target objects dealt with and in duration of continuous concentration. For females only, ranking in orienteering performance was related to quality of concentration (ratio of correct to…

  10. Theoretical analysis of photon statistics on excited number of modes and dopant concentration in Er3+:Ti:LiNbO, waveguide amplifiers

    NASA Astrophysics Data System (ADS)

    Ducariu, A.; Constantin, G. C.; Puscas, N. N.

    2005-08-01

    In the small gain approximation and the unsaturated regime in this paper we report some original results concerning the evaluation of the Fano factor, statistical fluctuation and spontaneous emission factor which characterize the photon statistics on the number of excited modes, dopant concentration and power pumping in the single and double pass Er3+ - doped LiNbO, straight waveguide amplifiers pumped near 1484 nm using erfc, Gaussian and constant profile of the Er3+ ions in LiNbO, crystal. We demonstrated that for 50 mW input pump power the Poisson photon statistics are maintained in the above mentioned amplifiers for concentrations of the Er ions smaller than l026 m-3 and also high gains and low noise figures are achievable. The obtained results can be used for the design of optoelectronic integrated circuits.

  11. Tethered balloon-based particle number concentration, and size distribution vertical profiles within the lower troposphere of Shanghai

    NASA Astrophysics Data System (ADS)

    Zhang, Kun; Wang, Dongfang; Bian, Qinggen; Duan, Yusen; Zhao, Mengfei; Fei, Dongnian; Xiu, Guangli; Fu, Qingyan

    2017-04-01

    A tethered balloon-based measurement campaign of particle number concentration (PNC) and particle number size distribution (PNSD) in the size range of 15.7-661.2 nm was conducted within the lower troposphere of 1000 m in Shanghai, a Chinese megacity, during December of 2015. The meteorological conditions, PNC, and PNSD were synchronously measured at the ground-based station as well as by the tethered balloon. On ground level, the 88.2 nm particles were found to have the highest PNC. The Pearson correlation analysis based on the ground level data showed NO2 had a strong correlation with PNC. The synchronous measurement of PNC and PNSD at the ground station and on the tethered balloon showed that the 15.7-200 nm particles had higher PNC on ground level, but the PNC of 200-661.2 nm particles was higher at 400 m. One haze event (Dec 22nd-Dec 23rd) was selected for detailed discussion on the variation of vertical profiles of PNSD and PNC. The vertical distribution of characteristics of PNC and PNSD were observed and compared. Results indicated that the highest MaxDm (the diameter with the highest PNC) during those three launches all appeared at a high altitude, usually above 300 m. Compared to the clean days, the relatively bigger MaxDm at each height in the haze days also indicated regional transport of pollutants might contribute to more to that haze event.

  12. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Energy and Environmental Research Corporation (GE EER) has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GEmore » EER (prime contractor) was awarded a Vision 21 program from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GE EER, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal/opportunity fuels and air are simultaneously converted into separate streams of (1) pure hydrogen that can be utilized in fuel cells, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure oxygen-depleted air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on process modeling work, has an estimated process efficiency of 68%, based on electrical and H{sub 2} energy outputs relative to the higher heating value of coal, and an estimated equivalent electrical efficiency of 60%. The Phase I R&D program will determine the operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates lab-, bench- and pilot-scale studies to demonstrate the UFP technology. This is the tenth quarterly technical progress report for the Vision 21 UFP

  13. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Energy and Environmental Research Corporation (GE EER) has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GEmore » EER was awarded a Vision 21 program from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GE EER, California Energy Commission, Southern Illinois University at Carbondale, and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal/opportunity fuels and air are simultaneously converted into separate streams of (1) pure hydrogen that can be utilized in fuel cells, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure oxygen-depleted air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on process modeling work, has an estimated process efficiency of 68%, based on electrical and H{sub 2} energy outputs relative to the higher heating value of coal, and an estimated equivalent electrical efficiency of 60%. The Phase I R&D program will determine the operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates lab-, bench- and pilot-scale studies to demonstrate the UFP technology. This is the ninth quarterly technical progress report for the Vision 21 UFP program supported by U.S. DOE NETL

  14. FUEL-FLEXIBLE GASIFICATION-COMBUSTION TECHNOLOGY FOR PRODUCTION OF H2 AND SEQUESTRATION-READY CO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Rizeq; Janice West; Arnaldo Frydman

    It is expected that in the 21st century the Nation will continue to rely on fossil fuels for electricity, transportation, and chemicals. It will be necessary to improve both the process efficiency and environmental impact performance of fossil fuel utilization. GE Global Research (GEGR) has developed an innovative fuel-flexible Unmixed Fuel Processor (UFP) technology to produce H{sub 2}, power, and sequestration-ready CO{sub 2} from coal and other solid fuels. The UFP module offers the potential for reduced cost, increased process efficiency relative to conventional gasification and combustion systems, and near-zero pollutant emissions including NO{sub x}. GEGR (prime contractor) was awardedmore » a Vision 21 program from U.S. DOE NETL to develop the UFP technology. Work on this Phase I program started on October 1, 2000. The project team includes GEGR, Southern Illinois University at Carbondale (SIU-C), California Energy Commission (CEC), and T. R. Miles, Technical Consultants, Inc. In the UFP technology, coal/opportunity fuels and air are simultaneously converted into separate streams of (1) pure hydrogen that can be utilized in fuel cells, (2) sequestration-ready CO{sub 2}, and (3) high temperature/pressure oxygen-depleted air to produce electricity in a gas turbine. The process produces near-zero emissions and, based on process modeling with best-case scenario assumptions, has an estimated process efficiency of 68%, based on electrical and H{sub 2} energy outputs relative to the higher heating value of coal, and an estimated equivalent electrical efficiency of 60%. The Phase I R&D program will determine the operating conditions that maximize separation of CO{sub 2} and pollutants from the vent gas, while simultaneously maximizing coal conversion efficiency and hydrogen production. The program integrates lab-, bench- and pilot-scale studies to demonstrate the UFP technology. This is the eleventh quarterly technical progress report for the Vision 21 UFP program

  15. Beef heifers with diminished numbers of antral follicles have decreased uterine protein concentrations

    USDA-ARS?s Scientific Manuscript database

    Previous research demonstrated a favorable relationship between the number of follicles detectable in the bovine ovary by ultrasonography and fertility, and bovine females with diminished numbers of antral follicles had smaller reproductive tracts. Therefore, we hypothesized that uterine function w...

  16. A new method for calculating number concentrations of cloud condensation nuclei based on measurements of a three-wavelength humidified nephelometer system

    NASA Astrophysics Data System (ADS)

    Tao, Jiangchuan; Zhao, Chunsheng; Kuang, Ye; Zhao, Gang; Shen, Chuanyang; Yu, Yingli; Bian, Yuxuan; Xu, Wanyun

    2018-02-01

    The number concentration of cloud condensation nuclei (CCN) plays a fundamental role in cloud physics. Instrumentations of direct measurements of CCN number concentration (NCCN) based on chamber technology are complex and costly; thus a simple way for measuring NCCN is needed. In this study, a new method for NCCN calculation based on measurements of a three-wavelength humidified nephelometer system is proposed. A three-wavelength humidified nephelometer system can measure the aerosol light-scattering coefficient (σsp) at three wavelengths and the light-scattering enhancement factor (fRH). The Ångström exponent (Å) inferred from σsp at three wavelengths provides information on mean predominate aerosol size, and hygroscopicity parameter (κ) can be calculated from the combination of fRH and Å. Given this, a lookup table that includes σsp, κ and Å is established to predict NCCN. Due to the precondition for the application, this new method is not suitable for externally mixed particles, large particles (e.g., dust and sea salt) or fresh aerosol particles. This method is validated with direct measurements of NCCN using a CCN counter on the North China Plain. Results show that relative deviations between calculated NCCN and measured NCCN are within 30 % and confirm the robustness of this method. This method enables simplerNCCN measurements because the humidified nephelometer system is easily operated and stable. Compared with the method using a CCN counter, another advantage of this newly proposed method is that it can obtain NCCN at lower supersaturations in the ambient atmosphere.

  17. A Microfluidic Cell Concentrator

    PubMed Central

    Warrick, Jay; Casavant, Ben; Frisk, Megan; Beebe, David

    2010-01-01

    Cell concentration via centrifugation is a ubiquitous step in many cell culture procedures. At the macroscale, centrifugation suffers from a number of limitations particularly when dealing with small numbers of cells (e.g., less than 50,000). On the other hand, typical microscale methods for cell concentration can affect cell physiology and bias readouts of cell behavior and function. In this paper, we present a microfluidic concentrator device that utilizes the effects of gravity to allow cells to gently settle out of a suspension into a collection region without the use of specific adhesion ligands. Dimensional analysis was performed to compare different device designs and was verified with flow modeling to optimize operational parameters. We are able to concentrate low-density cell suspensions in a microfluidic chamber, achieving a cell loss of only 1.1 ± 0.6% (SD, n=7) with no observed loss during a subsequent cell staining protocol which incorporates ~36 complete device volume replacements. This method provides a much needed interface between rare cell samples and microfluidic culture assays. PMID:20843010

  18. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

    PubMed

    de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria

    2015-12-24

    Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

  19. Determining Number Concentrations and Diameters of Polystyrene Particles by Measuring the Effective Refractive Index of Colloids Using Surface Plasmon Resonance.

    PubMed

    Tuoriniemi, Jani; Moreira, Beatriz; Safina, Gulnara

    2016-10-04

    The capabilities of surface plasmon resonance (SPR) for characterization of colloidal particles were evaluated for 100, 300, and 460 nm nominal diameter polystyrene (PS) latexes. First the accuracy of measuring the effective refractive index (n eff ) of turbid colloids using SPR was quantified. It was concluded that for submicrometer sized PS particles the accuracy is limited by the reproducibility between replicate injections of samples. An SPR method was developed for obtaining the particle mean diameter (d part ) and the particle number concentration (c p ) by fitting the measured n eff of polystyrene (PS) colloids diluted in series with theoretical values calculated using the coherent scattering theory (CST). The d part and c p determined using SPR agreed with reference values obtained from size distributions measured by scanning electron microscopy (SEM), and the mass concentrations stated by the manufacturer. The 100 nm particles adsorbed on the sensing surface, which hampered the analysis. Once the adsorption problem has been overcome, the developed SPR method has potential to become a versatile tool for characterization of colloidal particles. In particular, SPR could form the basis of rapid and accurate methods for measuring the c p of submicrometer particles in dispersion.

  20. Aviation-Related Impacts on Ultrafine Particle Number Concentrations Outside and Inside Residences near an Airport

    PubMed Central

    2018-01-01

    Jet engine exhaust is a significant source of ultrafine particles and aviation-related emissions can adversely impact air quality over large areas surrounding airports. We investigated outdoor and indoor ultrafine particle number concentrations (PNC) from 16 residences located in two study areas in the greater Boston metropolitan area (MA, USA) for evidence of aviation-related impacts. During winds from the direction of Logan International Airport, that is, impact-sector winds, an increase in outdoor and indoor PNC was clearly evident at all seven residences in the Chelsea study area (∼4–5 km from the airport) and three out of nine residences in the Boston study area (∼5–6 km from the airport); the median increase during impact-sector winds compared to other winds was 1.7-fold for both outdoor and indoor PNC. Across all residences during impact-sector and other winds, median outdoor PNC were 19 000 and 10 000 particles/cm3, respectively, and median indoor PNC were 7000 and 4000 particles/cm3, respectively. Overall, our results indicate that aviation-related outdoor PNC infiltrate indoors and result in significantly higher indoor PNC. Our study provides compelling evidence for the impact of aviation-related emissions on residential exposures. Further investigation is warranted because these impacts are not expected to be unique to Logan airport. PMID:29411612

  1. Correlations of particle number concentrations and metals with nitrogen oxides and other traffic-related air pollutants in Glasgow and London

    NASA Astrophysics Data System (ADS)

    Sánchez Jiménez, Araceli; Heal, Mathew R.; Beverland, Iain J.

    2012-07-01

    Particle number concentration (PNC) and transition metal content are implicated in the health effects of airborne particulate matter (PM) but they are difficult to measure so consequently their temporal and spatial variations are not well characterized. Daily concentrations of PNC and particle-bound water-soluble metals (V, Cr, Mn, Fe, Ni, Cu, As, Cd and Pb) were measured at background and kerbside sites in Glasgow and London to examine if other metrics of air pollution such as optical darkness (absorbance) of collected filter samples of PM, gravimetric PM, and NO, NO2 and CO gas concentrations, can be used as surrogates for the temporal and spatial variations of the former. NO2 and NOx exhibited a high degree of within-site correlation and with PNC and water-soluble metals (Fe, Cu, As, Cd, Pb) at background sites in both cities. There is therefore potential to use NO2 and NOx as surrogates for PNC and water-soluble metal at background sites. However, correlation was weaker in complex street canyon environments where pollutant concentrations are strongly affected by local sources and the small-scale variations in pollutant dispersion induced by the wind regimes within street canyons. The corollary of the high correlation between NO2 and PNC and water-soluble metals at the background sites is that the latter pollutants may act as confounders for health effects attributed to NO2 from such sites. Concentrations of CO cannot be used as a surrogate for PNC. Increments in daily NOx and NO2 concentrations between trafficked and background sites were shown to be a simple and novel surrogate for daily spatial variation of PNC; for example, increments in NOx explained 78-79% of the variance in PNC at the paired sites in both Glasgow and London, but relationships were city specific. The increments in NOx also explained 70% of the spatial variation in Cu and Ni in Glasgow but not in London. Weekly NO2 measurements derived from passive diffusion tubes were also shown to

  2. Solar concentrator

    NASA Technical Reports Server (NTRS)

    Simpson, J. G. (Inventor)

    1979-01-01

    An improved solar concentrator is characterized by a number of elongated supporting members arranged in substantial horizontal parallelism with the axis and intersecting a common curve. A tensioned sheet of flexible reflective material is disposed in engaging relation with the supporting members in order to impart to the tensioned sheet a catenary configuration.

  3. Accuracy of the raw-data-based effective atomic numbers and monochromatic CT numbers for contrast medium with a dual-energy CT technique.

    PubMed

    Kawahara, Daisuke; Ozawa, Shuichi; Yokomachi, Kazushi; Tanaka, Sodai; Higaki, Toru; Fujioka, Chikako; Suzuki, Tatsuhiko; Tsuneda, Masato; Nakashima, Takeo; Ohno, Yoshimi; Nagata, Yasushi

    2018-02-01

    To evaluate the accuracy of raw-data-based effective atomic number (Z eff ) values and monochromatic CT numbers for contrast material of varying iodine concentrations, obtained using dual-energy CT. We used a tissue characterization phantom and varying concentrations of iodinated contrast medium. A comparison between the theoretical values of Z eff and that provided by the manufacturer was performed. The measured and theoretical monochromatic CT numbers at 40-130 keV were compared. The average difference between the Z eff values of lung (inhale) inserts in the tissue characterization phantom was 81.3% and the average Z eff difference was within 8.4%. The average difference between the Z eff values of the varying concentrations of iodinated contrast medium was within 11.2%. For the varying concentrations of iodinated contrast medium, the differences between the measured and theoretical monochromatic CT values increased with decreasing monochromatic energy. The Z eff and monochromatic CT numbers in the tissue characterization phantom were reasonably accurate. The accuracy of the raw-data-based Z eff values was higher than that of image-based Z eff values in the tissue-equivalent phantom. The accuracy of Z eff values in the contrast medium was in good agreement within the maximum SD found in the iodine concentration range of clinical dynamic CT imaging. Moreover, the optimum monochromatic energy for human tissue and iodinated contrast medium was found to be 70 keV. Advances in knowledge: The accuracy of the Z eff values and monochromatic CT numbers of the contrast medium created by raw-data-based, dual-energy CT could be sufficient in clinical conditions.

  4. Chronic Obstructive Pulmonary Disease-Derived Circulating Cells Release IL-18 and IL-33 under Ultrafine Particulate Matter Exposure in a Caspase-1/8-Independent Manner

    PubMed Central

    De Falco, Gianluigi; Colarusso, Chiara; Terlizzi, Michela; Popolo, Ada; Pecoraro, Michela; Commodo, Mario; Minutolo, Patrizia; Sirignano, Mariano; D’Anna, Andrea; Aquino, Rita P.; Pinto, Aldo; Molino, Antonio; Sorrentino, Rosalinda

    2017-01-01

    Chronic obstructive pulmonary disease (COPD) is considered the fourth-leading causes of death worldwide; COPD is caused by inhalation of noxious indoor and outdoor particles, especially cigarette smoke that represents the first risk factor for this respiratory disorder. To mimic the effects of particulate matter on COPD, we isolated peripheral blood mononuclear cells (PBMCs) and treated them with combustion-generated ultrafine particles (UFPs) obtained from two different fuel mixtures, namely, pure ethylene and a mixture of ethylene and dimethylfuran (the latter mimicking the combustion of biofuels). UFPs were separated in two fractions: (1) sub-10 nm particles, named nano organic carbon (NOC) particles and (2) primarily soot particles of 20–40 nm and their agglomerates (200 nm). We found that both NOC and soot UFPs induced the release of IL-18 and IL-33 from unstable/exacerbated COPD-derived PBMCs. This effect was associated with higher levels of mitochondrial dysfunction and derived reactive oxygen species, which were higher in PBMCs from unstable COPD patients after combustion-generated UFP exposure. Moreover, lower mRNA expression of the repairing enzyme OGG1 was associated with the higher levels of 8-OH-dG compared with non-smoker and smokers. It was interesting that IL-18 and IL-33 release from PBMCs of unstable COPD patients was not NOD-like receptor 3/caspase-1 or caspase-8-dependent, but rather correlated to caspase-4 release. This effect was not evident in stable COPD-derived PBMCs. Our data suggest that combustion-generated UFPs induce the release of caspase-4-dependent inflammasome from PBMCs of COPD patients compared with healthy subjects, shedding new light into the biology of this key complex in COPD. PMID:29123531

  5. Modeling Population Exposure to Ultrafine Particles in a Major Italian Urban Area

    PubMed Central

    Spinazzè, Andrea; Cattaneo, Andrea; Peruzzo, Carlo; Cavallo, Domenico M.

    2014-01-01

    Average daily ultrafine particles (UFP) exposure of adult Milan subpopulations (defined on the basis of gender, and then for age, employment or educational status), in different exposure scenarios (typical working day in summer and winter) were simulated using a microenvironmental stochastic simulation model. The basic concept of this kind of model is that time-weighted average exposure is defined as the sum of partial microenvironmental exposures, which are determined by the product of UFP concentration and time spent in each microenvironment. In this work, environmental concentrations were derived from previous experimental studies that were based on microenvironmental measurements in the city of Milan by means of personal or individual monitoring, while time-activity patterns were derived from the EXPOLIS study. A significant difference was observed between the exposures experienced in winter (W: 28,415 pt/cm3) and summer (S: 19,558 pt/cm3). Furthermore, simulations showed a moderate difference between the total exposures experienced by women (S: 19,363 pt/cm3; W: 27,623 pt/cm3) and men (S: 18,806 pt/cm3; W: 27,897 pt/cm3). In addition, differences were found as a function of (I) age, (II) employment status and (III) educational level; accordingly, the highest total exposures resulted for (I) 55–59 years old people, (II) housewives and students and (III) people with higher educational level (more than 10 years of scholarity). Finally, significant differences were found between microenvironment-specific exposures. PMID:25321878

  6. Ultrafine particles cause cytoskeletal dysfunctions in macrophages: role of intracellular calcium

    PubMed Central

    Möller, Winfried; Brown, David M; Kreyling, Wolfgang G; Stone, Vicki

    2005-01-01

    Background Particulate air pollution is reported to cause adverse health effects in susceptible individuals. Since most of these particles are derived form combustion processes, the primary composition product is carbon with a very small diameter (ultrafine, less than 100 nm in diameter). Besides the induction of reactive oxygen species and inflammation, ultrafine particles (UFP) can cause intracellular calcium transients and suppression of defense mechanisms of alveolar macrophages, such as impaired migration or phagocytosis. Methods In this study the role of intracellular calcium transients caused by UFP was studied on cytoskeleton related functions in J774A.1 macrophages. Different types of fine and ultrafine carbon black particles (CB and ufCB, respectively), such as elemental carbon (EC90), commercial carbon (Printex 90), diesel particulate matter (DEP) and urban dust (UD), were investigated. Phagosome transport mechanisms and mechanical cytoskeletal integrity were studied by cytomagnetometry and cell viability was studied by fluorescence microscopy. Macrophages were exposed in vitro with 100 and 320 μg UFP/ml/million cells for 4 hours in serum free medium. Calcium antagonists Verapamil, BAPTA-AM and W-7 were used to block calcium channels in the membrane, to chelate intracellular calcium or to inhibit the calmodulin signaling pathways, respectively. Results Impaired phagosome transport and increased cytoskeletal stiffness occurred at EC90 and P90 concentrations of 100 μg/ml/million cells and above, but not with DEP or UD. Verapamil and W-7, but not BAPTA-AM inhibited the cytoskeletal dysfunctions caused by EC90 or P90. Additionally the presence of 5% serum or 1% bovine serum albumin (BSA) suppressed the cytoskeletal dysfunctions. Cell viability showed similar results, where co-culture of ufCB together with Verapamil, W-7, FCS or BSA produced less cell dead compared to the particles only. PMID:16202162

  7. Exposure to fine and ultrafine particles from secondhand smoke in public places before and after the smoking ban, Italy 2005.

    PubMed

    Valente, Pasquale; Forastiere, Francesco; Bacosi, Antonella; Cattani, Giorgio; Di Carlo, Simonetta; Ferri, Monica; Figà-Talamanca, Irene; Marconi, Achille; Paoletti, Luigi; Perucci, Carlo; Zuccaro, Piergiorgio

    2007-10-01

    A smoking ban in all indoor public places was enforced in Italy on 10 January 2005. We compared indoor air quality before and after the smoking ban by monitoring the indoor concentrations of fine (<2.5 microm diameter, PM2.5) and ultrafine particulate matter (<0.1 microm diameter, UFP). PM2.5 and ultrafine particles were measured in 40 public places (14 bars, six fast food restaurants, eight restaurants, six game rooms, six pubs) in Rome, before and after the introduction of the law banning smoking (after 3 and 12 months). Measurements were taken using real time particle monitors (DustTRAK Mod. 8520 TSI; Ultra-fine Particles Counter-TRAK Model 8525 TSI). The PM2.5 data were scaled using a correction equation derived from a comparison with the reference method (gravimetric measurement). The study was completed by measuring urinary cotinine, and pre-law and post-law enforcement among non-smoking employees at these establishments In the post-law period, PM2.5 decreased significantly from a mean concentration of 119.3 microg/m3 to 38.2 microg/m3 after 3 months (p<0.005), and then to 43.3 microg/m3 a year later (p<0.01). The UFP concentrations also decreased significantly from 76,956 particles/cm3 to 38,079 particles/cm3 (p<0.0001) and then to 51,692 particles/cm3 (p<0.01). Similarly, the concentration of urinary cotinine among non-smoking workers decreased from 17.8 ng/ml to 5.5 ng/ml (p<0.0001) and then to 3.7 ng/ml (p<0.0001). The application of the smoking ban led to a considerable reduction in the exposure to indoor fine and ultrafine particles in hospitality venues, confirmed by a contemporaneous reduction of urinary cotinine.

  8. Genotoxic effects of daily personal exposure to particle mass and number concentrations on buccal cells

    NASA Astrophysics Data System (ADS)

    de Almeida, Daniela S.; da Costa, Silvano César; Ribeiro, Marcos; Moreira, Camila A. B.; Beal, Alexandra; Squizzato, Rafaela; Rudke, Anderson Paulo; Rafee, Sameh Adib Abou; Martins, Jorge A.; Palioto, Graciana Freitas; Kumar, Prashant; Martins, Leila D.

    2018-03-01

    The aim of this study is to assess personal exposure to Particle Number Concentrations (PNC) in four size ranges between 0.3 and 10 μm, and particulate matter (PM1; PM2.5; PM4; PM10) in order to evaluate possible genotoxic effects through a comet assay in buccal cells. A convenience cohort of 30 individuals from a Brazilian medium-sized city was selected. These individuals aged between 20 and 61 and worked in typical job categories (i.e., administrative, commerce, education, general services and transport). They were recruited to perform personal exposure measurements during their typical daily routine activities, totaling 240 h of sampling. The 8-h average mass concentrations in air for volunteers ranged from 2.4 to 31.8 μg m-3 for PM1, 4.2-45.1 μg m-3 for PM2.5, 7.9-66.1 μg m-3 for PM4 and from 23.1 to 131.7 μg m-3 for PM10. The highest PNC variation was found for 0.3-0.5 range, between 14 and 181 particles cm-3, 1 to 14 particles cm-3 for the 0.5-1.0 range, 0.2 to 2 particles cm-3 for the 1.0-2.5 range, and 0.06 to 0.7 particles cm-3 for the 2.5-10 range. Volunteers in the 'education' category experienced the lowest inhaled dose of PM2.5, as opposed to those involved in 'commercial' activities with the highest doses for PM10 (1.63 μg kg-1 h-1) and PM2.5 (0.61 μg kg-1 h-1). The predominant cause for these high doses was associated with the proximity of the workplace to the street and vehicle traffic. The comet assay performed in buccal cells indicated that the volunteers in 'commerce' category experienced the highest damage to their DeoxyriboNucleic Acid (DNA) compared with the control category (i.e. 'education'). These results indicate the variability in personal exposure of the volunteers in different groups, and the potential damage to DNA was much higher for those spending time in close proximity to the vehicle sources (e.g. commercial services) leading to exposure to a higher fraction of fine particles. This study builds understanding on the exposure

  9. Comparison of carcinogen, carbon monoxide, and ultrafine particle emissions from narghile waterpipe and cigarette smoking: Sidestream smoke measurements and assessment of second-hand smoke emission factors

    PubMed Central

    Daher, Nancy; Saleh, Rawad; Jaroudi, Ezzat; Sheheitli, Hiba; Badr, Thérèse; Sepetdjian, Elizabeth; Al Rashidi, Mariam; Saliba, Najat; Shihadeh, Alan

    2009-01-01

    The lack of scientific evidence on the constituents, properties, and health effects of second-hand waterpipe smoke has fueled controversy over whether public smoking bans should include the waterpipe. The purpose of this study was to investigate and compare emissions of ultrafine particles (UFP, <100 nm), carcinogenic polyaromatic hydrocarbons (PAH), volatile aldehydes, and carbon monoxide (CO) for cigarettes and narghile (shisha, hookah) waterpipes. These smoke constituents are associated with a variety of cancers, and heart and pulmonary diseases, and span the volatility range found in tobacco smoke. Sidestream cigarette and waterpipe smoke was captured and aged in a 1 m3 Teflon-coated chamber operating at 1.5 air changes per hour (ACH). The chamber was characterized for particle mass and number surface deposition rates. UFP and CO concentrations were measured online using a fast particle spectrometer (TSI 3090 Engine Exhaust Particle Sizer), and an indoor air quality monitor. Particulate PAH and gaseous volatile aldehydes were captured on glass fiber filters and DNPH-coated SPE cartridges, respectively, and analyzed off-line using GC–MS and HPLC–MS. PAH compounds quantified were the 5- and 6-ring compounds of the EPA priority list. Measured aldehydes consisted of formaldehyde, acetaldehyde, acrolein, methacrolein, and propionaldehyde. We found that a single waterpipe use session emits in the sidestream smoke approximately four times the carcinogenic PAH, four times the volatile aldehydes, and 30 times the CO of a single cigarette. Accounting for exhaled mainstream smoke, and given a habitual smoker smoking rate of 2 cigarettes per hour, during a typical one-hour waterpipe use session a waterpipe smoker likely generates ambient carcinogens and toxicants equivalent to 2–10 cigarette smokers, depending on the compound in question. There is therefore good reason to include waterpipe tobacco smoking in public smoking bans. PMID:20161525

  10. Comparison of carcinogen, carbon monoxide, and ultrafine particle emissions from narghile waterpipe and cigarette smoking: Sidestream smoke measurements and assessment of second-hand smoke emission factors

    NASA Astrophysics Data System (ADS)

    Daher, Nancy; Saleh, Rawad; Jaroudi, Ezzat; Sheheitli, Hiba; Badr, Thérèse; Sepetdjian, Elizabeth; Al Rashidi, Mariam; Saliba, Najat; Shihadeh, Alan

    2010-01-01

    The lack of scientific evidence on the constituents, properties, and health effects of second-hand waterpipe smoke has fueled controversy over whether public smoking bans should include the waterpipe. The purpose of this study was to investigate and compare emissions of ultrafine particles (UFP, <100 nm), carcinogenic polyaromatic hydrocarbons (PAH), volatile aldehydes, and carbon monoxide (CO) for cigarettes and narghile (shisha, hookah) waterpipes. These smoke constituents are associated with a variety of cancers, and heart and pulmonary diseases, and span the volatility range found in tobacco smoke. Sidestream cigarette and waterpipe smoke was captured and aged in a 1 m 3 Teflon-coated chamber operating at 1.5 air changes per hour (ACH). The chamber was characterized for particle mass and number surface deposition rates. UFP and CO concentrations were measured online using a fast particle spectrometer (TSI 3090 Engine Exhaust Particle Sizer), and an indoor air quality monitor. Particulate PAH and gaseous volatile aldehydes were captured on glass fiber filters and DNPH-coated SPE cartridges, respectively, and analyzed off-line using GC-MS and HPLC-MS. PAH compounds quantified were the 5- and 6-ring compounds of the EPA priority list. Measured aldehydes consisted of formaldehyde, acetaldehyde, acrolein, methacrolein, and propionaldehyde. We found that a single waterpipe use session emits in the sidestream smoke approximately four times the carcinogenic PAH, four times the volatile aldehydes, and 30 times the CO of a single cigarette. Accounting for exhaled mainstream smoke, and given a habitual smoker smoking rate of 2 cigarettes per hour, during a typical one-hour waterpipe use session a waterpipe smoker likely generates ambient carcinogens and toxicants equivalent to 2-10 cigarette smokers, depending on the compound in question. There is therefore good reason to include waterpipe tobacco smoking in public smoking bans.

  11. Ice crystal number concentration measured at mountain-top research stations - What do we measure?

    NASA Astrophysics Data System (ADS)

    Beck, A.; Henneberger, J.; Fugal, J. P.; David, R.; Larcher, L.; Lohmann, U.

    2017-12-01

    To assess the impact of surface processes (e.g. blowing snow and hoar frost) on the ice crystal number concentrations (ICNCs) measured at mountain-top research stations, vertical profiles of ICNCs were observed up to a height of 10 m at the Sonnblick Observatory (SBO) in the Hohen Tauern Region, Austria. Independent of the presence of a cloud, the observed ICNCs decrease with height. This suggests a strong impact of surface processes on ICNCs measured at mountain-top research stations. Consequently, the measured ICNCs are not representative of the cloud, which limits the relevance of ground-based measurements for atmospheric studies. When the SBO was cloud free, the observed ICNCs reached several hundreds per liter near the surface and gradually decreased by more than two orders of magnitudes within the observed height interval of 10 m. The observed ice crystals had predominantly irregular habits, which is expected from surface processes. During in-cloud conditions, the ICNCs decreased between a factor of five and ten, if the ICNC at the surface was larger than 100 l-1. For one case study, the ICNC for regular and irregular ice crystals showed a similar relative decrease with height, which is not expected from surface processes. Therefore, we propose two near-surface processes that potentially enrich ICNCs near the surface and explain these findings: Either sedimenting ice crystals are captured in a turbulent layer above the surface or the ICNC is enhanced in a convergence zone, as the cloud is forced over a mountain. These two processes would also have an impact on ICNCs measured at mountain-top stations if the surrounding surface is not snow covered. Thus, ground-based measured ICNCs are uncharacteristic of the cloud properties aloft.

  12. Using mobile monitoring to visualise diurnal variation of traffic pollutants across two near-highway neighbourhoods

    NASA Astrophysics Data System (ADS)

    Pattinson, Woodrow; Longley, Ian; Kingham, Simon

    2014-09-01

    It is widely accepted that concentrations of primary traffic pollutants can vary substantially across relatively small urban areas. Fixed-site monitors have been shown to be largely inadequate for representing concentrations at nearby locations, resulting in the increasing use of spatial modelling or mobile sampling methods to achieve spatial saturation. In this study, we employ the use of a simple bicycle to sample concentrations of ultrafine particles (UFPs), carbon monoxide (CO) and particulate matter (PM10) at two small areas (<2.5 km2) in South Auckland, New Zealand. Portable instruments were mounted inside a custom-built casing at the front of the bicycle and every street within each study area was sampled in a grid-like fashion, at four times of day (07:00, 12:00, 17:00 and 22:00). Each area has a six-lane highway running through its centre and the core aim was to visualise and describe spatial variability of pollutant levels about the highway, main arterials and quieter streets, at periods of contrasting meteorological and traffic conditions. A total of 20 sampling runs in each area (five at each of the four timings) were conducted. Meteorological data were logged continuously at background sites within each study area. Results show that the influence of highway traffic (UFPs, CO) was strongest during the mornings and late evenings when wind speeds were low, while for the midday and afternoon timings, concentrations were highest at the arterial and shopping zones. Concentrations of PM10 appeared to be strongest in the residential areas during mornings and late evenings, suggesting an influence of wood burning for home heating. For all timings combined, for all three pollutants, it appears the arterial roads featuring shops and numerous intersections with traffic lights, had a stronger influence on concentrations than the busier but more free-flowing highways. This study provides not only an insight into microspatial hotspot variation across suburbs, but

  13. Concentrator hot-spot testing, phase 1

    NASA Technical Reports Server (NTRS)

    Gonzalez, C. C.

    1987-01-01

    Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator module hot-spot qualification test is the test developed for flat-plate modules, issues, such as providing cell illumination, introduce additional complexities into the testing procedure. The same general guidelines apply for protecting concentrator modules from hot-spot stressing as apply to flat-plate modules. Therefore, recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. In addition, a new method for determining the cell temperature in the laboratory or in the field is discussed.

  14. Low-Reynolds-number swimming at pycnoclines.

    PubMed

    Doostmohammadi, Amin; Stocker, Roman; Ardekani, Arezoo M

    2012-03-06

    Microorganisms play pivotal functions in the trophic dynamics and biogeochemistry of aquatic ecosystems. Their concentrations and activities often peak at localized hotspots, an important example of which are pycnoclines, where water density increases sharply with depth due to gradients in temperature or salinity. At pycnoclines organisms are exposed to different environmental conditions compared to the bulk water column, including reduced turbulence, slow mass transfer, and high particle and predator concentrations. Here we show that, at an even more fundamental level, the density stratification itself can affect microbial ecology at pycnoclines, by quenching the flow signature, increasing the energetic expenditure, and stifling the nutrient uptake of motile organisms. We demonstrate this through numerical simulations of an archetypal low-Reynolds-number swimmer, the "squirmer." We identify the Richardson number--the ratio of buoyancy forces to viscous forces--as the fundamental parameter that quantifies the effects of stratification. These results demonstrate an unexpected effect of buoyancy on low-Reynolds-number swimming, potentially affecting a broad range of abundant organisms living at pycnoclines in oceans and lakes.

  15. Improvement of In Situ PCR by Optimization of PCR Cycle Number and Proteinase K Concentration: Localization of X Chromosome-Linked Phosphoglycerate Kinase-1 Gene in Mouse Reproductive Organs

    PubMed Central

    Hishikawa, Yoshitaka; An, Shucai; Yamamoto-Fukuda, Tomomi; Shibata, Yasuaki; Koji, Takehiko

    2009-01-01

    In situ polymerase chain reaction (in situ PCR), which can detect a few copies of genes within a cell by amplifying the target gene, was developed to better understand the biological functions of tissues. In this study, we optimized the protocol conditions for the detection of X chromosome-linked phosphoglycerate kinase-1 (pgk-1) gene in paraffin-embedded sections of mouse reproductive organs. The effects of various concentrations of proteinase K (PK) and PCR cycle numbers were examined. To label the amplified DNA, we used digoxigenin-dUTP (Dig), Cy-3-dUTP (Cy-3), or FluorX-dCTP (FluorX). The optimal concentration of PK was 50 µg/ml for the ovary and 10 µg/ml for the testis. Ten PCR cycles were optimal for Dig and 25 cycles were optimal for FluorX and Cy-3 in the ovary and testis. The signal-to-noise ratio of FluorX and Cy-3 for ovarian tissue was better than that of Dig. Using the above conditions, we detected 1–4 and 1–2 spots of pgk-1 in the nuclei of granulosa and germ cells, respectively. Our results indicate that in situ PCR is useful for detecting a specific gene in paraffin-embedded sections under optimized conditions of both PCR cycle number and PK concentration. PMID:19492023

  16. Miniaturized Cassegrainian concentrator concept demonstration

    NASA Technical Reports Server (NTRS)

    Patterson, R. E.; Rauschenbach, H. S.

    1982-01-01

    High concentration ratio photovoltaic systems for space applications have generally been considered impractical because of perceived difficulties in controlling solar cell temperatures to reasonably low values. A miniaturized concentrator system is now under development which surmounts this objection by providing acceptable solar cell temperatures using purely passive cell cooling methods. An array of identical miniaturized, rigid Cassegrainian optical systems having a low f-number with resulting short dimensions along their optical axes are rigidly mounted into a frame to form a relatively thin concentrator solar array panel. A number of such panels, approximately 1.5 centimeters thick, are wired as an array and are folded against one another for launch in a stowed configuration. Deployment on orbit is similar to the deployment of conventional planar honeycomb panel arrays or flexible blanket arrays. The miniaturized concept was conceived and studied in the 1978-80 time frame. Progress in the feasibility demonstration to date is reported.

  17. Most probable number methodology for quantifying dilute concentrations and fluxes of Escherichia coli O157:H7 in surface waters.

    PubMed

    Jenkins, M B; Endale, D M; Fisher, D S; Gay, P A

    2009-02-01

    To better understand the transport and enumeration of dilute densities of Escherichia coli O157:H7 in agricultural watersheds, we developed a culture-based, five tube-multiple dilution most probable number (MPN) method. The MPN method combined a filtration technique for large volumes of surface water with standard selective media, biochemical and immunological tests, and a TaqMan confirmation step. This method determined E. coli O157:H7 concentrations as low as 0.1 MPN per litre, with a 95% confidence level of 0.01-0.7 MPN per litre. Escherichia coli O157:H7 densities ranged from not detectable to 9 MPN per litre for pond inflow, from not detectable to 0.9 MPN per litre for pond outflow and from not detectable to 8.3 MPN per litre for within pond. The MPN methodology was extended to mass flux determinations. Fluxes of E. coli O157:H7 ranged from <27 to >10(4) MPN per hour. This culture-based method can detect small numbers of viable/culturable E. coli O157:H7 in surface waters of watersheds containing animal agriculture and wildlife. This MPN method will improve our understanding of the transport and fate of E. coli O157:H7 in agricultural watersheds, and can be the basis of collections of environmental E. coli O157:H7.

  18. Recent Greenhouse Gas Concentrations

    DOE Data Explorer

    Blasing, T. J.

    2016-01-01

    Gases typically measured in parts per million (ppm), parts per billion (ppb) or parts per trillion (ppt) are presented separately to facilitate comparison of numbers. Global Warming Potentials (GWPs) and atmospheric lifetimes are from the Intergovernmental Panel on Climate Change (IPCC, 2013, Table 8.A.1), except for the atmospheric lifetime of carbon dioxide (CO2) which is explained in footnote 4. Additional material on greenhouse gases can be found in CDIAC's Reference Tools. To find out how CFCs, HFCs, HCFCs, and halons are named, see Name that compound: The numbers game for CFCs, HFCs, HCFCs, and Halons. Concentrations given apply to the lower 75-80 percent of the atmosphere, known as the troposphere. Sources of the current and preindustrial concentrations of the atmospheric gases listed in the table below are given in the footnotes. Investigators at the National Oceanic and Atmospheric Administration have provided the recent concentrations. Much of the data provided results from the work of various investigators at institutions other than CDIAC, and represent considerable effort on their part. We ask as a basic professional courtesy that you acknowledge the primary sources, indicated in the footnotes below, or in the links given in the footnotes. Concentrations of ozone and water vapor are spatially and temporally variable due to their short atmospheric lifetimes. A vertically and horizontally averaged water vapor concentration is about 5,000 ppm. Globally averaged water vapor concentration is difficult to measure precisely because it varies from one place to another and from one season to the next. This precludes a precise determination of changes in water vapor since pre-industrial time. However, a warmer atmosphere will likely contain more water vapor than at present. For a more detailed statement on water vapor from the National Oceanic and Atmospheric Administration, see the "water vapor" page at http://lwf.ncdc.noaa.gov/oa/climate/gases.html

  19. [Dependence of the concentration of the demi-maximal action of a channel blocker on the agonist concentration].

    PubMed

    Skorinkin, A I; Valeev, N V; Shaĭkhutdinova, A R

    2005-01-01

    Based on the analysis of kinetic scheme of blocking of open channels at any number of blocker binding sites, the dependence of current on blocker concentration was found. A variant of this dependence for a trapping blocker was also found. The restrictions of the applicability of the Hill equation and the necessity of taking into account the dependence of the concentration of demi-maximal blocker action (IC50) on the concentration of agonist were shown.

  20. Physico-Chemical Characterization of Fine and Ultrafine Particles Emitted during Diesel Particulate Filter Active Regeneration of Euro5 Diesel Vehicles.

    PubMed

    R'Mili, Badr; Boréave, Antoinette; Meme, Aurelie; Vernoux, Philippe; Leblanc, Mickael; Noël, Ludovic; Raux, Stephane; D'Anna, Barbara

    2018-03-06

    Diesel particulate filters (DPFs) are commonly employed in modern passenger cars to comply with current particulate matter (PM) emission standards. DPFs requires periodic regeneration to remove the accumulated matter. During the process, high-concentration particles, in both nucleation and accumulation modes, are emitted. Here, we report new information on particle morphology and chemical composition of fine (FPs) and ultrafine particles (UFPs) measured downstream of the DPF during active regeneration of two Euro 5 passenger cars. The first vehicle was equipped with a close-coupled diesel oxidation catalyst (DOC) and noncatalyzed DPF combined with fuel borne catalyst and the second one with DOC and a catalyzed-diesel particle filter (CDPF). Differences in PM emission profiles of the two vehicles were related to different after treatment design, regeneration strategies, and vehicle characteristics and mileage. Particles in the nucleation mode consisted of ammonium bisulfate, sulfate and sulfuric acid, suggesting that the catalyst desulfation is the key process in the formation of UFPs. Larger particles and agglomerates, ranging from 90 to 600 nm, consisted of carbonaceous material (soot and soot aggregates) coated by condensable material including organics, ammonium bisulfate and sulfuric acid. Particle emission in the accumulation mode was due to the reduced filtration efficiency (soot cake oxidation) throughout the regeneration process.

  1. Deriving Cloud Droplet Number Concentration from Combined Airborne Lidar and Polarimeter Measurements from the NAAMES Mission

    NASA Astrophysics Data System (ADS)

    Hair, J. W.; Hostetler, C. A.; Brian, C.; Ziemba, L. D.; Alexandrov, M. D.; Hu, Y.; Crosbie, E.; Scarino, A. J.; Butler, C. F.; Moore, R.; Berkoff, T.; Harper, D. B.; Cook, A. L.; Hare, R. J.; Lee, J.; Anderson, B. E.

    2017-12-01

    The NASA Langley High Spectral Resolution lidar (HSRL) and the NASA GISS Research Scanning Polarimeter (RSP) were deployed onboard the NASA C-130 during two field campaigns as part of the NASA's Earth Venture-Suborbital (EVS) North Atlantic Aerosol and Marine Ecosystems Study (NAAMES) during November 2015 and May 2016. The main objectives of NAAMES are to study the phases of the North Atlantic annual plankton cycle and to investigate remote marine aerosols and their impact on boundary layer clouds. Lidar retrievals of the cloud-top extinction and lidar ratio (extinction/backscatter ratio) of boundary layer clouds are presented. These retrievals are unique and are enabled by two characteristics of the lidar: employment of the high-spectral-resolution lidar technique and the high-vertical-resolution (1.25 m) the Langley HSRL instrument. The HSRL lidar ratio retrievals are compared to estimates derived from Research Scanning Polarimeter data to assess consistency between the two remote sensors. The measurements of effective size and variance from RSP are combined with the HSRL cloud top extinction to retrieve the cloud droplet number concentrations (CDNC). The lidar+polarimeter CDNC estimates are compared to those from the Cloud Droplet Probe (CDP) that is part of the NASA Langley Aerosol Research Group Experiment (LARGE) instrument suite. Histograms of the CNDC measurements from remote sensors are shown to highlight the observed differences in CDNC between the November and May deployments.

  2. Influence of anatomical location on CT numbers in cone beam computed tomography.

    PubMed

    Oliveira, Matheus L; Tosoni, Guilherme M; Lindsey, David H; Mendoza, Kristopher; Tetradis, Sotirios; Mallya, Sanjay M

    2013-04-01

    To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K₂HPO₄) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K₂HPO₄ phantoms were measured, and the relationship between CT numbers and K₂HPO₄ concentration was examined. The measured CT numbers of the K₂HPO₄ phantoms were compared between anatomical sites. At all six anatomical locations, there was a strong linear relationship between CT numbers and K₂HPO₄ concentration (R(2)>0.93). However, the absolute CT numbers varied considerably with the anatomical location. The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. EFFECT OF THE NUMBER OF SPRINT REPETITIONS ON THE VARIATION OF BLOOD LACTATE CONCENTRATION IN REPEATED SPRINT SESSIONS

    PubMed Central

    Dardouri, W.; Haj-Sassi, R.; Castagna, C.; Chamari, K.; Souissi, N.

    2014-01-01

    The aim of the present study was to examine the effect of number of sprint repetitions on the variation of blood lactate concentration (blood [La]) during different repeated-sprint sessions in order to find the appropriate number of sprint repetitions that properly simulates the physiological demands of team sport competitions. Twenty male team-sport players (age, 22.2 ± 2.9 years) performed several repeated-sprint sessions (RSS) consisting of 1, 2, 3, 4, 5, 9, or 10 repetitions of 30 m shuttle sprints (2 × 15 m) with 30 s recovery in between. The blood [La] was obtained after 3 min of recovery at the end of each RSS. The present study showed that for RSS of 3 sprints (RSS3) there was a high increase (p<0.001) in blood [La], which reached approximately fivefold resting values (9.4±1.7 mmol · l−1) and then remained unchanged for the RSS of 4 and 5 sprints (9.6±1.4 and 10.5±1.9 mmol · l−1, p=0.96 and 0.26, respectively). After RSS9 and RSS10 blood [La] further significantly increased to 12.6 and 12.7 mmol · l−1, p<0.001, respectively. No significant difference was found between RSS3, RSS4 and RSS5 for the percentage of sprint speed decrement (Sdec) (1.5±1.2; 2.0±1.1 and 2.6±1.4%, respectively). There was also no significant difference between RSS9 and RSS10 for Sdec (3.9±1.3% and 4.5±1.4%, respectively). In conclusion, the repeated-sprint protocol composed of 5 shuttle sprint repetitions is more representative of the blood lactate demands of the team sports game intensity. PMID:24899781

  4. Alpha-Lipoic Acid Reduces LDL-Particle Number and PCSK9 Concentrations in High-Fat Fed Obese Zucker Rats

    PubMed Central

    Carrier, Bradley; Wen, Shin; Zigouras, Sophia; Browne, Richard W.; Li, Zhuyun; Patel, Mulchand S.; Williamson, David L.; Rideout, Todd C.

    2014-01-01

    We characterized the hypolipidemic effects of alpha-lipoic acid (LA, R-form) and examined the associated molecular mechanisms in a high fat fed Zucker rat model. Rats (n = 8) were assigned to a high fat (HF) diet or the HF diet with 0.25% LA (HF-LA) for 30 days and pair fed to remove confounding effects associated with the anorectic properties of LA. Compared with the HF controls, the HF-LA group was protected against diet-induced obesity (102.5±3.1 vs. 121.5±3.6,% change BW) and hypercholesterolemia with a reduction in total-C (−21%), non-HDL-C (−25%), LDL-C (−16%), and total LDL particle number (−46%) and an increase in total HDL particles (∼22%). This cholesterol-lowering response was associated with a reduction in plasma PCSK9 concentration (−70%) and an increase in hepatic LDLr receptor protein abundance (2 fold of HF). Compared with the HF-fed animals, livers of LA-supplemented animals were protected against TG accumulation (−46%), likely through multiple mechanisms including: a suppressed lipogenic response (down-regulation of hepatic acetyl-CoA carboxylase and fatty acid synthase expression); enhanced hepatic fat oxidation (increased carnitine palmitoyltransferase Iα expression); and enhanced VLDL export (increased hepatic diacylglycerol acyltransferase and microsomal triglyceride transfer protein expression and elevated plasma VLDL particle number). Study results also support an enhanced fatty acid uptake (2.8 fold increase in total lipase activity) and oxidation (increased CPT1β protein abundance) in muscle tissue in LA-supplemented animals compared with the HF group. In summary, in the absence of a change in caloric intake, LA was effective in protecting against hypercholesterolemia and hepatic fat accumulation under conditions of strong genetic and dietary predisposition toward obesity and dyslipidemia. PMID:24595397

  5. Performance Analysis and Optimization of Concentrating Solar Thermoelectric Generator

    NASA Astrophysics Data System (ADS)

    Lamba, Ravita; Manikandan, S.; Kaushik, S. C.

    2018-06-01

    A thermodynamic model for a concentrating solar thermoelectric generator considering the Thomson effect combined with Fourier heat conduction, Peltier, and Joule heating has been developed and optimized in MATLAB environment. The temperatures at the hot and cold junctions of the thermoelectric generator were evaluated by solving the energy balance equations at both junctions. The effects of the solar concentration ratio, input electrical current, number of thermocouples, and electrical load resistance ratio on the power output and energy and exergy efficiencies of the system were studied. Optimization studies were carried out for the STEG system, and the optimum number of thermocouples, concentration ratio, and resistance ratio determined. The results showed that the optimum values of these parameters are different for conditions of maximum power output and maximum energy and exergy efficiency. The optimum values of the concentration ratio and load resistance ratio for maximum energy efficiency of 5.85% and maximum exergy efficiency of 6.29% were found to be 180 and 1.3, respectively, with corresponding power output of 4.213 W. Furthermore, at higher concentration ratio (C = 600), the optimum number of thermocouples was found to be 101 for maximum power output of 13.75 W, maximum energy efficiency of 5.73%, and maximum exergy efficiency of 6.16%. Moreover, the optimum number of thermocouple was the same for conditions of maximum power output and energy and exergy efficiency. The results of this study may provide insight for design of actual concentrated solar thermoelectric generator systems.

  6. Influence of trans-boundary biomass burning impacted air masses on submicron particle number concentrations and size distributions

    NASA Astrophysics Data System (ADS)

    Betha, Raghu; Zhang, Zhe; Balasubramanian, Rajasekhar

    2014-08-01

    Submicron particle number concentration (PNC) and particle size distribution (PSD) in the size range of 5.6-560 nm were investigated in Singapore from 27 June 2009 through 6 September 2009. Slightly hazy conditions lasted in Singapore from 6 to 10 August. Backward air trajectories indicated that the haze was due to the transport of biomass burning impacted air masses originating from wild forest and peat fires in Sumatra, Indonesia. Three distinct peaks in the morning (08:00-10:00), afternoon (13:00-15:00) and evening (16:00-20:00) were observed on a typical normal day. However, during the haze period no distinct morning and afternoon peaks were observed and the PNC (39,775 ± 3741 cm-3) increased by 1.5 times when compared to that during non-haze periods (26,462 ± 6017). The morning and afternoon peaks on the normal day were associated with the local rush hour traffic while the afternoon peak was induced by new particle formation (NPF). Diurnal profiles of PNCs and PSDs showed that primary particle peak diameters were large during the haze (60 nm) period when compared to that during the non-haze period (45.3 nm). NPF events observed in the afternoon period on normal days were suppressed during the haze periods due to heavy particle loading in atmosphere caused by biomass burning impacted air masses.

  7. Hot-spot qualification testing of concentrator modules

    NASA Technical Reports Server (NTRS)

    Gonzalez, C. C.; Sugimura, R. S.; Ross, R. G., Jr.

    1987-01-01

    Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current, forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator-module hot-spot qualification test is the test developed for flat-plate modules, issues such as providing cell illumination introduce additional complexities into the testing procedure. The results indicate that the same general guidelines apply to protecting concentrator modules from hot-spot stressing as apply to flat-plate modules, and recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. A method for determining the cell temperature in the laboratory or in the field is discussed.

  8. Traffic emission factors of ultrafine particles: effects from ambient air.

    PubMed

    Janhäll, Sara; Molnar, Peter; Hallquist, Mattias

    2012-09-01

    Ultrafine particles have a significant detrimental effect on both human health and climate. In order to abate this problem, it is necessary to identify the sources of ultrafine particles. A parameterisation method is presented for estimating the levels of traffic-emitted ultrafine particles in terms of variables describing the ambient conditions. The method is versatile and could easily be applied to similar datasets in other environments. The data used were collected during a four-week period in February 2005, in Gothenburg, as part of the Göte-2005 campaign. The specific variables tested were temperature (T), relative humidity (RH), carbon monoxide concentration (CO), and the concentration of particles up to 10 μm diameter (PM(10)); all indicators are of importance for aerosol processes such as coagulation and gas-particle partitioning. These variables were selected because of their direct effect on aerosol processes (T and RH) or as proxies for aerosol surface area (CO and PM(10)) and because of their availability in local monitoring programmes, increasing the usability of the parameterization. Emission factors are presented for 10-100 nm particles (ultrafine particles; EF(ufp)), for 10-40 nm particles (EF(10-40)), and for 40-100 nm particles (EF(40-100)). For EF(40-100) no effect of ambient conditions was found. The emission factor equations are calculated based on an emission factor for NO(x) of 1 g km(-1), thus the particle emission factors are easily expressed in units of particles per gram of NO(x) emitted. For 10-100 nm particles the emission factor is EF(ufp) = 1.8 × 10(15) × (1 - 0.095 × CO - 3.2 × 10(-3) × T) particles km(-1). Alternative equations for the EFs in terms of T and PM(10) concentration are also presented.

  9. 21 CFR 146.150 - Canned concentrated orange juice.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... dilution ratio greater than 3 plus 1 is “Canned concentrated orange juice, ___ plus 1” or “Canned orange juice concentrate, ___ plus 1”, the blank being filled in with the whole number showing the dilution ratio; for example, “Canned orange juice concentrate, 4 plus 1”. However, where the label bears...

  10. 21 CFR 146.150 - Canned concentrated orange juice.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... dilution ratio greater than 3 plus 1 is “Canned concentrated orange juice, ___ plus 1” or “Canned orange juice concentrate, ___ plus 1”, the blank being filled in with the whole number showing the dilution ratio; for example, “Canned orange juice concentrate, 4 plus 1”. However, where the label bears...

  11. 21 CFR 146.150 - Canned concentrated orange juice.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... dilution ratio greater than 3 plus 1 is “Canned concentrated orange juice, ___ plus 1” or “Canned orange juice concentrate, ___ plus 1”, the blank being filled in with the whole number showing the dilution ratio; for example, “Canned orange juice concentrate, 4 plus 1”. However, where the label bears...

  12. 21 CFR 146.150 - Canned concentrated orange juice.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... dilution ratio greater than 3 plus 1 is “Canned concentrated orange juice, ___ plus 1” or “Canned orange juice concentrate, ___ plus 1”, the blank being filled in with the whole number showing the dilution ratio; for example, “Canned orange juice concentrate, 4 plus 1”. However, where the label bears...

  13. 21 CFR 146.150 - Canned concentrated orange juice.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... dilution ratio greater than 3 plus 1 is “Canned concentrated orange juice, ___ plus 1” or “Canned orange juice concentrate, ___ plus 1”, the blank being filled in with the whole number showing the dilution ratio; for example, “Canned orange juice concentrate, 4 plus 1”. However, where the label bears...

  14. Aerosol size distribution and new particle formation events in the suburb of Xi'an, northwest China

    NASA Astrophysics Data System (ADS)

    Peng, Yan; Liu, Xiaodong; Dai, Jin; Wang, Zhao; Dong, Zipeng; Dong, Yan; Chen, Chuang; Li, Xingmin; Zhao, Na; Fan, Chao

    2017-03-01

    Particle number concentration and size distribution are important for better understanding the characteristics of aerosols. However, their measurements are scarce in western China. Based on the first measurement of particle number size distribution (10-487 nm) in the suburb of Xi'an, northwest China from November 2013 to December 2014, the seasonal, monthly and diurnal average particle number concentrations were investigated, and the characteristics of new particle formation (NPF) events and their dependencies on meteorological parameters also discussed. The results showed that the annual average particle number concentrations in the nucleation (NNUC), Aitken (NAIT), and Accumulation (NACC) size ranges were 960 cm-3, 4457 cm-3, 3548 cm-3, respectively. The mean total particle number concentration (NTOT) was 8965 cm-3 and largely dominated by particles in Aitken mode. The number concentration was dominated by particles around 67.3 nm in spring, summer and fall, while about 89.8 nm in winter. The percentage of the ultrafine size range (UFP, particles of diameter below 100 nm) to total particle number concentration was 63.2%, 69.6%, 62.2% and 58.1% in four seasons. The diurnal variation of the nucleation mode particles was mainly influenced by NPF events in summer, while by both traffic densities and NPF events in spring, fall and winter. The diurnal variation of the number concentration of Aitken mode particles correlated with the traffic emission in spring, fall and winter, while in summer it more correlated with contribution of the growth of the nucleation mode particles. The burst of nucleation mode particles typically started in the daytime (08:15-16:05, LST). The growth rates of nucleated particles ranged from 2.8 to 10.7 nm h-1 with an average of 5.0 ± 1.9 nm h-1. Among observed 66 NPF events from 347 effective measurement days, 85 percent of their air masses came from north or northwest China, resulting in a low concentration of pre-existing particles, and

  15. Bruise chromophore concentrations over time

    NASA Astrophysics Data System (ADS)

    Duckworth, Mark G.; Caspall, Jayme J.; Mappus, Rudolph L., IV; Kong, Linghua; Yi, Dingrong; Sprigle, Stephen H.

    2008-03-01

    During investigations of potential child and elder abuse, clinicians and forensic practitioners are often asked to offer opinions about the age of a bruise. A commonality between existing methods of bruise aging is analysis of bruise color or estimation of chromophore concentration. Relative chromophore concentration is an underlying factor that determines bruise color. We investigate a method of chromophore concentration estimation that can be employed in a handheld imaging spectrometer with a small number of wavelengths. The method, based on absorbance properties defined by Beer-Lambert's law, allows estimation of differential chromophore concentration between bruised and normal skin. Absorption coefficient data for each chromophore are required to make the estimation. Two different sources of this data are used in the analysis- generated using Independent Component Analysis and taken from published values. Differential concentration values over time, generated using both sources, show correlation to published models of bruise color change over time and total chromophore concentration over time.

  16. Transmissive Diffractive Optical Element Solar Concentrators

    NASA Technical Reports Server (NTRS)

    Baron, Richard; Moynihan, Philip; Price, Douglas

    2008-01-01

    Solar-thermal-radiation concentrators in the form of transmissive diffractive optical elements (DOEs) have been proposed as alternatives to mirror-type solar concentrators now in use. In comparison with functionally equivalent mirror-type solar concentrators, the transmissive, diffractive solar concentrators would weigh and cost less, and would be subject to relaxed mechanical tolerances. A DOE concentrator would be made from a thin, flat disk or membrane of a transmissive material having a suitable index of refraction. By virtue of its thinness, the DOE concentrator would have an areal mass density significantly less than that of a functionally equivalent conventional mirror. The DOE concentrator would have a relatively wide aperture--characterized by a focal-length/aperture-diameter ratio ('f number') on the order of 1. A kinoform (a surface-relief phase hologram) of high diffractive order would be microfabricated onto one face of the disk. The kinoform (see figure) would be designed to both diffract and refract incident solar radiation onto a desired focal region, without concern for forming an image of the Sun. The high diffractive order of this kinoform (in contradistinction to the low diffractive orders of some other kinoforms) would be necessary to obtain the desired f number of 1, which, in turn, would be necessary for obtaining a desired concentration ratio of 2,500 or greater. The design process of optimizing the concentration ratio of a proposed DOE solar concentrator includes computing convolutions of the optical bandwidth of the Sun with the optical transmission of the diffractive medium. Because, as in the cases of other non-imaging, light-concentrating optics, image quality is not a design requirement, the process also includes trading image quality against concentration ratio. A baseline design for one example calls for an aperture diameter of 1 m. This baseline design would be scalable to a diameter as large as 10 m, or to a smaller diameter for a

  17. Respiratory Effects of Fine and Ultrafine Particles from Indoor Sources—A Randomized Sham-Controlled Exposure Study of Healthy Volunteers

    PubMed Central

    Soppa, Vanessa J.; Schins, Roel P. F.; Hennig, Frauke; Hellack, Bryan; Quass, Ulrich; Kaminski, Heinz; Kuhlbusch, Thomas A. J.; Hoffmann, Barbara; Weinmayr, Gudrun

    2014-01-01

    Particulate air pollution is linked to impaired respiratory health. We analyzed particle emissions from common indoor sources (candles burning (CB), toasting bread (TB), frying sausages (FS)) and lung function in 55 healthy volunteers (mean age 33.0 years) in a randomized cross-over controlled exposure study. Lung-deposited particle surface area concentration (PSC), size-specific particle number concentration (PNC) up to 10 µm, and particle mass concentration (PMC) of PM1, PM2.5 and PM10 were determined during exposure (2 h). FEV1, FVC and MEF25%–75% was measured before, 4 h and 24 h after exposure. Wilcoxon-rank sum tests (comparing exposure scenarios) and mixed linear regression using particle concentrations and adjusting for personal characteristics, travel time and transportation means before exposure sessions were performed. While no effect was seen comparing the exposure scenarios and in the unadjusted model, inverse associations were found for PMC from CB and FS in relation to FEV1 and MEF25%–75%. with a change in 10 µg/m3 in PM2.5 from CB being associated with a change in FEV1 of −19 mL (95%-confidence interval:−43; 5) after 4 h. PMC from TB and PNC of UFP were not associated with lung function changes, but PSC from CB was. Elevated indoor fine particles from certain sources may be associated with small decreases in lung function in healthy adults. PMID:25000149

  18. Line-focus concentrating collector program

    NASA Technical Reports Server (NTRS)

    Dugan, V. L.

    1980-01-01

    The Line-Focus Concentrating Collector Program has emphasized the development and dissemination of concentrating solar technology in which the reflected sunlight is focused onto a linear or line receiver. Although a number of different types of line-focus concentrators were developed, the parabolic trough has gained the widest acceptance and utilization within the industrial and applications sectors. The trough is best applied for application scenarios which require temperatures between 140 and 600 F. Another concept, the bowl, is investigated for applications which may require temperatures in the range between 600 and 1200 F. Current technology emphases are upon the reduction of system installation cost and the implementation of production oriented engineering.

  19. Napping-Ultra Flash Profile as a Tool for Category Identification and Subsequent Model System Formulation of Caramel Corn Products.

    PubMed

    Mayhew, Emily; Schmidt, Shelly; Lee, Soo-Yeun

    2016-07-01

    In a novel approach to formulation, the flash descriptive profiling technique Napping-Ultra Flash Profile (Napping-UFP) was used to characterize a wide range of commercial caramel corn products. The objectives were to identify product categories, develop model systems based on product categories, and correlate analytical parameters with sensory terms generated through the Napping-UFP exercise. In one 2 h session, 12 panelists participated in 4 Napping-UFP exercises, describing and grouping, on a 43×56 cm paper sheet, 12 commercial caramel corn samples by degree of similarity, globally and in terms of aroma-by-mouth, texture, and taste. The coordinates of each sample's placement on the paper sheet and descriptive terms generated by the panelists were used to conduct Multiple Factor Analysis (MFA) and hierarchical clustering of the samples. Strong trends in the clustering of samples across the 4 Napping-UFP exercises resulted in the determination of 3 overarching types of commercial caramel corn: "small-scale dark" (typified by burnt, rich caramel corn), "large-scale light" (typified by light and buttery caramel corn), and "large-scale dark" (typified by sweet and molasses-like caramel corn). Representative samples that best exemplified the properties of each category were used as guides in the formulation of 3 model systems that represent the spread of commercial caramel corn products. Analytical testing of the commercial products, including aw measurement, moisture content determination, and thermal characterization via differential scanning calorimetry, were conducted and results related to sensory descriptors using Spearman's correlation. © 2016 Institute of Food Technologists®

  20. Phenomenology of summer ozone episodes over the Madrid Metropolitan Area, central Spain

    NASA Astrophysics Data System (ADS)

    Querol, Xavier; Alastuey, Andrés; Gangoiti, Gotzon; Perez, Noemí; Lee, Hong K.; Eun, Heeram R.; Park, Yonghee; Mantilla, Enrique; Escudero, Miguel; Titos, Gloria; Alonso, Lucio; Temime-Roussel, Brice; Marchand, Nicolas; Moreta, Juan R.; Arantxa Revuelta, M.; Salvador, Pedro; Artíñano, Begoña; García dos Santos, Saúl; Anguas, Mónica; Notario, Alberto; Saiz-Lopez, Alfonso; Harrison, Roy M.; Millán, Millán; Ahn, Kang-Ho

    2018-05-01

    Various studies have reported that the photochemical nucleation of new ultrafine particles (UFPs) in urban environments within high insolation regions occurs simultaneously with high ground ozone (O3) levels. In this work, we evaluate the atmospheric dynamics leading to summer O3 episodes in the Madrid air basin (central Iberia) by means of measuring a 3-D distribution of concentrations for both pollutants. To this end, we obtained vertical profiles (up to 1200 m above ground level) using tethered balloons and miniaturised instrumentation at a suburban site located to the SW of the Madrid Metropolitan Area (MMA), the Majadahonda site (MJDH), in July 2016. Simultaneously, measurements of an extensive number of air quality and meteorological parameters were carried out at three supersites across the MMA. Furthermore, data from O3 soundings and daily radio soundings were also used to interpret atmospheric dynamics.The results demonstrate the concatenation of venting and accumulation episodes, with relative lows (venting) and peaks (accumulation) in O3 surface levels. Regardless of the episode type, the fumigation of high-altitude O3 (arising from a variety of origins) contributes the major proportion of surface O3 concentrations. Accumulation episodes are characterised by a relatively thinner planetary boundary layer (< 1500 m at midday, lower in altitude than the orographic features), light synoptic winds, and the development of mountain breezes along the slopes of the Guadarrama Mountain Range (located W and NW of the MMA, with a maximum elevation of > 2400 m a.s.l.). This orographic-meteorological setting causes the vertical recirculation of air masses and enrichment of O3 in the lower tropospheric layers. When the highly polluted urban plume from Madrid is affected by these dynamics, the highest Ox (O3+ NO2) concentrations are recorded in the MMA.Vertical O3 profiles during venting episodes, with strong synoptic winds and a deepening of the planetary boundary

  1. Oxygen ion transference number of doped lanthanum gallate

    NASA Astrophysics Data System (ADS)

    Wang, Shizhong; Wu, Lingli; Gao, Jie; He, Qiong; Liu, Meilin

    The transference numbers for oxygen ion (t O) in several LaGaO 3-based materials are determined from oxygen concentration cells using the materials as the electrolyte, including La 0.8Sr 0.2Ga 0.8Mg 0.2O 3- δ (LSGM8282), La 0.8Sr 0.2Ga 0.8Mg 0.15Co 0.05O 3- δ (LSGMC5) and La 0.8Sr 0.2Ga 0.8Mg 0.115Co 0.085O 3- δ (LSGMC8.5). Analysis indicates that the accuracy in determination of oxygen ion transference number depends on the electrode polarization resistances of the concentration cell as well as the transport properties of the materials studied. For example, the ratio of open cell voltage to Nernst potential is a good approximation to the ionic transference number for LSGM8282. However, this approximation is no longer adequate for LSGMC5 and LSGMC8.5; the effect of electrode polarization resistances must be taken into consideration in estimation of the ionic transference numbers. In particular, the ionic transference number for LSGMC5 is as high as 0.99, suggesting that it is a promising electrolyte material for low-temperature solid-state electrochemical applications.

  2. Estimation hydrophilic-lipophilic balance number of surfactants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pawignya, Harsa, E-mail: harsa-paw@yahoo.co.id; Chemical Engineering Departement University of Pembangunan Nasional Yogyakarta; Prasetyaningrum, Aji, E-mail: ajiprasetyaningrum@gmail.com

    Any type of surfactant has a hydrophilic-lipophilic balance number (HLB number) of different. There are several methods for determining the HLB number, with ohysical properties of surfactant (solubility cloud point and interfacial tension), CMC methods and by thermodynamics properties (Free energy Gibbs). This paper proposes to determined HLB numbers from interfelation methods. The result of study indicated that the CMC method described by Hair and Moulik espesially for nonionic surfactant. The application of exess Gibbs free energy and by implication activity coefficient provides the ability to predict the behavior of surfactants in multi component mixtures of different concentration. Determination ofmore » HLB number by solubility and cloud point parameter is spesific for anionic and nonionic surfactant but this methods not available for cationic surfactants.« less

  3. Change in the plasmid copy number in acetic acid bacteria in response to growth phase and acetic acid concentration.

    PubMed

    Akasaka, Naoki; Astuti, Wiwik; Ishii, Yuri; Hidese, Ryota; Sakoda, Hisao; Fujiwara, Shinsuke

    2015-06-01

    Plasmids pGE1 (2.5 kb), pGE2 (7.2 kb), and pGE3 (5.5 kb) were isolated from Gluconacetobacter europaeus KGMA0119, and sequence analyses revealed they harbored 3, 8, and 4 genes, respectively. Plasmid copy numbers (PCNs) were determined by real-time quantitative PCR at different stages of bacterial growth. When KGMA0119 was cultured in medium containing 0.4% ethanol and 0.5% acetic acid, PCN of pGE1 increased from 7 copies/genome in the logarithmic phase to a maximum of 12 copies/genome at the beginning of the stationary phase, before decreasing to 4 copies/genome in the late stationary phase. PCNs for pGE2 and pGE3 were maintained at 1-3 copies/genome during all phases of growth. Under a higher concentration of ethanol (3.2%) the PCN for pGE1 was slightly lower in all the growth stages, and those of pGE2 and pGE3 were unchanged. In the presence of 1.0% acetic acid, PCNs were higher for pGE1 (10 copies/genome) and pGE3 (6 copies/genome) during the logarithmic phase. Numbers for pGE2 did not change, indicating that pGE1 and pGE3 increase their PCNs in response to acetic acid. Plasmids pBE2 and pBE3 were constructed by ligating linearized pGE2 and pGE3 into pBR322. Both plasmids were replicable in Escherichia coli, Acetobacter pasteurianus and G. europaeus, highlighting their suitability as vectors for acetic acid bacteria. Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  4. Airborne nanoparticle concentrations in the manufacturing of polytetrafluoroethylene (PTFE) apparel.

    PubMed

    Vosburgh, Donna J H; Boysen, Dane A; Oleson, Jacob J; Peters, Thomas M

    2011-03-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600 °C). This study addressed the potential for exposure to particulate matter from this sealing process by characterizing airborne particles in a facility that produces more than 1000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm⁻³)) compared with that measured in the office area (12,100 particles cm⁻³). Respirable mass concentrations were negligible throughout the facility (GM = 0.002 mg m⁻³) in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p < 0.0001). The sealing workers' breathing zone concentrations ranged from 147,000 particles cm⁻³ to 798,000 particles cm⁻³, and their seam responsibility significantly influenced their breathing zone concentrations (p = 0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations.

  5. Airborne Nanoparticle Concentrations in the Manufacturing of Polytetrafluoroethylene (PTFE) Apparel

    PubMed Central

    Vosburgh, Donna J.H.; Boysen, Dane A.; Oleson, Jacob J.; Peters, Thomas M.

    2016-01-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric, using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600°C). This study addressed the potential for exposure to particulate matter from this sealing process, by characterizing airborne particles in a facility that produces over 1,000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm−3) compared to that measured in the office area (12,100 particles cm−3). Respirable mass concentrations were negligible throughout the facility (GM=0.002 mg m−3 in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p<0.0001). The sealing workers’ breathing zone concentrations ranged from 147,000 particles cm−3 to 798,000 particles cm−3, and their seam responsibility significantly influenced their breathing zone concentrations (p=0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations. PMID:21347955

  6. Higher order relativistic galaxy number counts: dominating terms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, Jeppe TrØst; Durrer, Ruth, E-mail: Jeppe.Trost@nbi.dk, E-mail: Ruth.Durrer@unige.ch

    2017-03-01

    We review the number counts to second order concentrating on the terms which dominate on sub horizon scales. We re-derive the result for these terms and compare it with the different versions found in the literature. We generalize our derivation to higher order terms, especially the third order number counts which are needed to compute the 1-loop contribution to the power spectrum.

  7. Hydrophobicity and Charge Shape Cellular Metabolite Concentrations

    PubMed Central

    Bar-Even, Arren; Noor, Elad; Flamholz, Avi; Buescher, Joerg M.; Milo, Ron

    2011-01-01

    What governs the concentrations of metabolites within living cells? Beyond specific metabolic and enzymatic considerations, are there global trends that affect their values? We hypothesize that the physico-chemical properties of metabolites considerably affect their in-vivo concentrations. The recently achieved experimental capability to measure the concentrations of many metabolites simultaneously has made the testing of this hypothesis possible. Here, we analyze such recently available data sets of metabolite concentrations within E. coli, S. cerevisiae, B. subtilis and human. Overall, these data sets encompass more than twenty conditions, each containing dozens (28-108) of simultaneously measured metabolites. We test for correlations with various physico-chemical properties and find that the number of charged atoms, non-polar surface area, lipophilicity and solubility consistently correlate with concentration. In most data sets, a change in one of these properties elicits a ∼100 fold increase in metabolite concentrations. We find that the non-polar surface area and number of charged atoms account for almost half of the variation in concentrations in the most reliable and comprehensive data set. Analyzing specific groups of metabolites, such as amino-acids or phosphorylated nucleotides, reveals even a higher dependence of concentration on hydrophobicity. We suggest that these findings can be explained by evolutionary constraints imposed on metabolite concentrations and discuss possible selective pressures that can account for them. These include the reduction of solute leakage through the lipid membrane, avoidance of deleterious aggregates and reduction of non-specific hydrophobic binding. By highlighting the global constraints imposed on metabolic pathways, future research could shed light onto aspects of biochemical evolution and the chemical constraints that bound metabolic engineering efforts. PMID:21998563

  8. Factors Affecting Radon Concentration in Houses

    NASA Astrophysics Data System (ADS)

    Al-Sharif, Abdel-Latif; Abdelrahman, Y. S.

    2001-03-01

    The dangers to the human health upon exposure to radon and its daughter products is the main motivation behind the vast number of studies performed to find the concentration of radon in our living environment, including our houses. The presence of radon and its daughter products in houses are due to various sources including building materials and the soil under the houses. Many factors affect radon concentration in our houses, the elevation above ground level,ventilation, building materials and room usage being among these factors. In our paper, we discuss the effect of elevation above ground level, room usage and ventilation on the Radon concentration in houses. The faculty residences of the Mu'tah University (Jordan) were chosen in our study. Our results showed that the concentration of radon decreases with elevation. Ventilation rate was also found to affect radon concentration, where low concentrations observed for areas with good ventilation.

  9. Simultaneous all-optical determination of molecular concentration and extinction coefficient.

    PubMed

    Cho, Byungmoon; Tiwari, Vivek; Jonas, David M

    2013-06-04

    Absolute molecular number concentration and extinction coefficient are simultaneously determined from linear and nonlinear spectroscopic measurements. This method is based on measurements of absolute femtosecond pump-probe signals. Accounting for pulse propagation, we present a closed form expression for molecular number concentration in terms of absorbance, fluorescence, absolute pump-probe signal, and laser pulse parameters (pulse energy, spectrum, and spatial intensity profile); all quantities are measured optically. As in gravimetric and coulometric determinations of concentration, no standard samples are needed for calibration. The extinction coefficient can then be determined from the absorbance spectrum and the concentration. For fluorescein in basic methanol, the optically determined molar concentrations and extinction coefficients match gravimetric determinations to within 10% for concentrations from 0.032 to 0.540 mM, corresponding to absorbance from 0.06 to 1. In principle, this photonumeric method is extensible to transient chemical species for which other methods are not available.

  10. The Crossing Number of Graphs: Theory and Computation

    NASA Astrophysics Data System (ADS)

    Mutzel, Petra

    This survey concentrates on selected theoretical and computational aspects of the crossing number of graphs. Starting with its introduction by Turán, we will discuss known results for complete and complete bipartite graphs. Then we will focus on some historical confusion on the crossing number that has been brought up by Pach and Tóth as well as Székely. A connection to computational geometry is made in the section on the geometric version, namely the rectilinear crossing number. We will also mention some applications of the crossing number to geometrical problems. This review ends with recent results on approximation and exact computations.

  11. Concentrator Development

    NASA Technical Reports Server (NTRS)

    Owen, W. A.

    1984-01-01

    During the years of technology development by the Parabolic Dish program, the problems peculiar to tracking dishes have been explored in depth with particular emphasis on economics. Starting with the Precursor Concentrator, testing techniques and apparatus such as calorimeters and the flux mapper were developed. At the same time, mirrors were developed to have a long operating life as well as high performance. Commercially available equipment was evaluated as well. Building on all these elements, the Test Bed Concentrators were designed and built. With a peak intensity in the focal plane of over 17,500 suns and an average concentrator ratio over 3000 on an eight inch diameter aperture, they have proven to be the work horses of the technology. With a readily adjustable mirror array, they have proved to be an essential tool in the development of dish components, receivers, heat transport systems, instrumentation, controls, engines, and materials - all necessary to cost effective modules and plants. Utilizing the lessons learned from this technology, most cost effective systems were designed. These included Parabolic Dish Number 1 (PDC-1) and PDC-2 currently in final design by Acurex Corporation. Even more advanced concepts are being worked on, such as the Cassegranian systems by BDM Corporation.

  12. Concentration-Dependent Multiple Binding Sites on Saliva-Treated Hydroxyapatite for Streptococcus sanguis

    PubMed Central

    Gibbons, R. J.; Moreno, E. C.; Etherden, I.

    1983-01-01

    The influence of bacterial cell concentration on estimates of the number of binding sites and the affinity for the adsorption of a strain of Streptococcus sanguis to saliva-treated hydroxyapatite was determined, and the possible presence of multiple binding sites for this organism was tested. The range of concentrations of available bacteria varied from 4.7 × 106 to 5,960 × 106 cells per ml. The numbers of adsorbed bacteria increased over the entire range tested, but a suggestion of a break in an otherwise smooth adsorption isotherm was evident. Values for the number of binding sites and the affinity varied considerably depending upon the range of available bacterial concentrations used to estimate them; high correlation coefficients were obtained in all cases. The use of low bacterial cell concentrations yielded lower values for the number of sites and much higher values for the affinity constant than did the use of high bacterial cell concentrations. When data covering the entire range of bacterial concentrations were employed, values for the number of sites and the affinity were similar to those obtained by using only high bacterial cell concentrations. The simplest explanation for these results is that there are multiple binding sites for S. sanguis on saliva-treated hydroxyapatite surfaces. When present in low concentration, the streptococci evidently attach to more specific high-affinity sites which become saturated when higher bacterial concentrations are employed. The possibility of multiple binding sites was substantiated by comparing estimates of the adsorption parameters from a computer-simulated isotherm with those derived from the experimentally generated isotherm. A mathematical model describing bacterial adsorption to binary binding sites was further evidence for the existence of at least two classes of binding sites for S. sanguis. Far fewer streptococci adsorbed to experimental pellicles prepared from saliva depleted of bacterial aggregating

  13. Pilot study of high-performance air filtration for classroom applications.

    PubMed

    Polidori, A; Fine, P M; White, V; Kwon, P S

    2013-06-01

    A study was conducted to investigate the effectiveness of three air purification systems in reducing the exposure of children to air contaminants inside nine classrooms of three Southern California schools. Continuous and integrated measurements were conducted to monitor the indoor and outdoor concentrations of ultrafine particles (UFPs), fine and coarse particulate matter (PM2.5 and PM10 , respectively), black carbon (BC), and volatile organic compounds. An heating, ventilating, and air conditioning (HVAC)-based high-performance panel filter (HP-PF), a register-based air purifier (RS), and a stand-alone air cleaning system (SA) were tested alone and in different combinations for their ability to remove the monitored pollutants. The combination of a RS and a HP-PF was the most effective solution for lowering the indoor concentrations of BC, UFPs, and PM2.5 , with study average reductions between 87% and 96%. When using the HP-PF alone, reductions close to 90% were also achieved. In all cases, air quality conditions were improved substantially with respect to the corresponding baseline (preexisting) conditions. Data on the performance of the gas-absorbing media included in the RS and SA unit were inconclusive, and their effectiveness, lifetime, costs, and benefits must be further assessed before conclusions and recommendations can be made. The installation of effective air filtration devices in classrooms may be an important mitigation measure to help reduce the exposure of school children to indoor pollutants of outdoor origin including ultrafine particles and diesel particulate matter, especially at schools located near highly trafficked freeways, refineries, and other important sources of air toxics. Published 2012. This article is a US Government work and is in the public domain in the USA.

  14. Variability of particulate matter concentrations along roads and motorways determined by a moving measurement unit

    NASA Astrophysics Data System (ADS)

    Weijers, E. P.; Khlystov, A. Y.; Kos, G. P. A.; Erisman, J. W.

    The spatial variability of aerosol number and mass along roads was determined in different regions (urban, rural and coastal-marine) of the Netherlands. A condensation particle counter (CPC) and an optical aerosol spectrometer (LAS-X) were installed in a van along with a global positioning system (GPS). Concentrations were measured with high-time resolutions while driving allowing investigations not possible with stationary equipment. In particular, this approach proves to be useful to identify those locations where numbers and mass attain high levels ('hot spots'). In general, concentrations of number and mass of particulate matter increase along with the degree of urbanisation, with number concentration being the more sensitive indicator. The lowest particle numbers and PM 1-concentrations are encountered in a coastal and rural area: <5000 cm -3 and 6 μg m -3, respectively. The presence of sea-salt material along the North-Sea coast enhances PM >1-concentrations compared to inland levels. High-particle numbers are encountered on motorways correlating with traffic intensity; the largest average number concentration is measured on the ring motorway around Amsterdam: about 160 000 cm -3 (traffic intensity 100 000 veh day -1). Peak values occur in tunnels where numbers exceed 10 6 cm -3. Enhanced PM 1 levels (i.e. larger than 9 μg m -3) exist on motorways, major traffic roads and in tunnels. The concentrations of PM >1 appear rather uniformly distributed (below 6 μg m -3 for most observations). On the urban scale, (large) spatial variations in concentration can be explained by varying intensities of traffic and driving patterns. The highest particle numbers are measured while being in traffic congestions or when behind a heavy diesel-driven vehicle (up to 600×10 3 cm -3). Relatively high numbers are observed during the passages of crossings and, at a decreasing rate, on main roads with much traffic, quiet streets and residential areas with limited traffic. The

  15. An Intercomparison of Research Scanning Polarimeter Cloud Droplet Number Concentrations with Aerosol Properties over the Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Sinclair, K.; van Diedenhoven, B.; Cairns, B.; Alexandrov, M. D.; Ziemba, L. D.; Moore, R.; Crosbie, E.; Hostetler, C. A.

    2016-12-01

    Cloud droplet number concentration (CDNC) is a key parameter of of liquid clouds and is essential for the understanding of aerosol-cloud interaction. It couples surface aerosol composition and chemistry on the one hand and cloud reflectivity on the other. It impacts radiative forcing, cloud evolution, precipitation, global climate and, through observation, can be used to monitor the cloud albedo effect, or the first indirect effect. The North Atlantic and Marine Ecosystems Study (NAAMES), which is a NASA-led ship and air campaign that takes place off the east coast of Newfoundland, observed many low cloud decks and aerosols over a marine environment. This campaign has completed two of four deployments and provides an excellent opportunity for the Research Scanning Polarimeter (RSP) to cross-validate its approach of sensing CDNC with the Langley Aerosol Research Group Experiment's (LARGE's) Cloud Droplet Probe (CDP). The RSP is an airborne scanning sensor that provides high-precision measurements of polarized and full-intensity radiances at multiple angles over a wide spectral range. Each of the four NAAMES deployments are aligned to a specific annual event in the plankton cycle, along with other variations in environmental conditions. The Fall 2015 and spring 2016 deployments allow us to demonstrate and characterize the RSP's performance over a range of CDNCs and cloud types. We also assess correlations between the RSP CDNC measurements and atmospheric aerosol load. Using the LARGE Cloud Particle Counter (CPC) and Aerosol Mass Spectrometer (AMS), links between the size and type of aerosols and the RSP CDNC retrievals are explored.

  16. Numerical modeling of particle generation from ozone reactions with human-worn clothing in indoor environments

    NASA Astrophysics Data System (ADS)

    Rai, Aakash C.; Lin, Chao-Hsin; Chen, Qingyan

    2015-02-01

    Ozone-terpene reactions are important sources of indoor ultrafine particles (UFPs), a potential health hazard for human beings. Humans themselves act as possible sites for ozone-initiated particle generation through reactions with squalene (a terpene) that is present in their skin, hair, and clothing. This investigation developed a numerical model to probe particle generation from ozone reactions with clothing worn by humans. The model was based on particle generation measured in an environmental chamber as well as physical formulations of particle nucleation, condensational growth, and deposition. In five out of the six test cases, the model was able to predict particle size distributions reasonably well. The failure in the remaining case demonstrated the fundamental limitations of nucleation models. The model that was developed was used to predict particle generation under various building and airliner cabin conditions. These predictions indicate that ozone reactions with human-worn clothing could be an important source of UFPs in densely occupied classrooms and airliner cabins. Those reactions could account for about 40% of the total UFPs measured on a Boeing 737-700 flight. The model predictions at this stage are indicative and should be improved further.

  17. Synthesis of zinc ultrafine powders via the Guen–Miller flow-levitation method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jigatch, A. N., E-mail: jan@chph.ras.ru; Leipunskii, I. O.; Kuskov, M. L.

    2015-12-15

    Zinc ultrafine powders (UFPs) with the average particle size of 0.175 to 1.24 μm are synthesized via the flow-levitation method. The peculiarities of the formation of zinc UFPs are considered with respect to the carrier gas properties (heat capacity, thermal conductivity, and diffusion coefficient), as well as the gas flow parameters (pressure and flow rate). The obtained zinc particles are studied via scanning electron microscopy and X-ray diffraction. The factors determining the crystal structure of zinc particles and their size distribution are discussed as well. The data on oxidation of zinc stored in unsealed containers under normal conditions are alsomore » presented.« less

  18. Association of modeled long-term personal exposure to ultrafine particles with inflammatory and coagulation biomarkers.

    PubMed

    Lane, Kevin J; Levy, Jonathan I; Scammell, Madeleine K; Peters, Junenette L; Patton, Allison P; Reisner, Ellin; Lowe, Lydia; Zamore, Wig; Durant, John L; Brugge, Doug

    2016-01-01

    Long-term exposure to fine particulate matter has been linked to cardiovascular disease and systemic inflammatory responses; however, evidence is limited regarding the effects of long-term exposure to ultrafine particulate matter (UFP, <100nm). We used a cross-sectional study design to examine the association of long-term exposure to near-highway UFP with measures of systemic inflammation and coagulation. We analyzed blood samples from 408 individuals aged 40-91years living in three near-highway and three urban background areas in and near Boston, Massachusetts. We conducted mobile monitoring of particle number concentration (PNC) in each area, and used the data to develop and validate highly resolved spatiotemporal (hourly, 20m) PNC regression models. These models were linked with participant time-activity data to determine individual time-activity adjusted (TAA) annual average PNC exposures. Multivariable regression modeling and stratification were used to assess the association between TAA-PNC and single peripheral blood measures of high-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), tumor-necrosis factor alpha receptor II (TNFRII) and fibrinogen. After adjusting for age, sex, education, body mass index, smoking and race/ethnicity, an interquartile-range (10,000particles/cm(3)) increase in TAA-PNC had a positive non-significant association with a 14.0% (95% CI: -4.6%, 36.2%) positive difference in hsCRP, an 8.9% (95% CI: -0.4%, 10.9%) positive difference in IL-6, and a 5.1% (95% CI: -0.4%, 10.9%) positive difference in TNFRII. Stratification by race/ethnicity revealed that TAA-PNC had larger effect estimates for all three inflammatory markers and was significantly associated with hsCRP and TNFRII in white non-Hispanic, but not East Asian participants. Fibrinogen had a negative non-significant association with TAA-PNC. Our findings suggest an association between annual average near-highway TAA-PNC and subclinical inflammatory markers of CVD risk

  19. Number size distribution of particulate emissions of heavy-duty engines in real world test cycles

    NASA Astrophysics Data System (ADS)

    Lehmann, Urs; Mohr, Martin; Schweizer, Thomas; Rütter, Josef

    Five in-service engines in heavy-duty trucks complying with Euro II emission standards were measured on a dynamic engine test bench at EMPA. The particulate matter (PM) emissions of these engines were investigated by number and mass measurements. The mass of the total PM was evaluated using the standard gravimetric measurement method, the total number concentration and the number size distribution were measured by a Condensation Particle Counter (lower particle size cut-off: 7 nm) and an Electrical Low Pressure Impactor (lower particle size: 32 nm), respectively. The transient test cycles used represent either driving behaviour on the road (real-world test cycles) or a type approval procedure. They are characterised by the cycle power, the average cycle power and by a parameter for the cycle dynamics. In addition, the particle number size distribution was determined at two steady-state operating modes of the engine using a Scanning Mobility Particle Sizer. For quality control, each measurement was repeated at least three times under controlled conditions. It was found that the number size distributions as well as the total number concentration of emitted particles could be measured with a good repeatability. Total number concentration was between 9×10 11 and 1×10 13 particles/s (3×10 13-7×10 14 p/kWh) and mass concentration was between 0.09 and 0.48 g/kWh. For all transient cycles, the number mean diameter of the distributions lay typically at about 120 nm for aerodynamic particle diameter and did not vary significantly. In general, the various particle measurement devices used reveal the same trends in particle emissions. We looked at the correlation between specific gravimetric mass emission (PM) and total particle number concentration. The correlation tends to be influenced more by the different engines than by the test cycles.

  20. Differences in airborne particle and gaseous concentrations in urban air between weekdays and weekends

    NASA Astrophysics Data System (ADS)

    Morawska, L.; Jayaratne, E. R.; Mengersen, K.; Jamriska, M.; Thomas, S.

    Airborne particle number concentrations and size distributions as well as CO and NO x concentrations monitored at a site within the central business district of Brisbane, Australia were correlated with the traffic flow rate on a nearby freeway with the aim of investigating differences between weekday and weekend pollutant characteristics. Observations over a 5-year monitoring period showed that the mean number particle concentration on weekdays was (8.8±0.1)×10 3 cm -3 and on weekends (5.9±0.2)×10 3 cm -3—a difference of 47%. The corresponding mean particle number median diameters during weekdays and weekends were 44.2±0.3 and 50.2±0.2 nm, respectively. The differences in mean particle number concentration and size between weekdays and weekends were found to be statistically significant at confidence levels of over 99%. During a 1-year period of observation, the mean traffic flow rate on the freeway was 14.2×10 4 and 9.6×10 4 vehicles per weekday and weekend day, respectively—a difference of 48%. The mean diurnal variations of the particle number and the gaseous concentrations closely followed the traffic flow rate on both weekdays and weekends (correlation coefficient of 0.86 for particles). The overall conclusion, as to the effect of traffic on concentration levels of pollutant concentration in the vicinity of a major road (about 100 m) carrying traffic of the order of 10 5 vehicles per day, is that about a 50% increase in traffic flow rate results in similar increases of CO and NO x concentrations and a higher increase of about 70% in particle number concentration.

  1. About study of radiation flux carried out on the stand, which is designed for testing of space ultraviolet polarimeter

    NASA Astrophysics Data System (ADS)

    Nevodovskiy, P. V.; Vidmachenko, A. P.; Geraimchuk, M. D.; Ivahiv, O. V.

    2016-08-01

    In the Main Astronomical Observatory of NAS of Ukraine, National Technical University of Ukraine "KPI" and National University "Lviv Polytechnic" over the many years has accumulated considerable experience of work on the design and development of polarimeters, and created a working model of compact an onboard ultraviolet polarimeter (UFP) [1-6]. For debugging, research and testing as the entire layout of UFP and its individual parts we have created a special stand with complex equipment that allows carrying the following works. The structural construction of the stand allows obtaining characteristics as a whole unit, and its individual parts; obtaining spectral dependences and counting characteristics signal of the light radiation, and of dark signal; carry out the polarization measurements and more. For this stand developed a number of special techniques to study various parameters of all UFP appliance and its individual parts. Thus, for control - characteristics and calibration of elements of photo-detector system of electro-optical equipment, must use the reference emitters. But they are complicated and expensive. Therefore for simplified calibration and configuration of optical devices, it is expedient to use cheap and small in size, but specially selected LEDs. For this, developed for testing of UFP stand, has been modernized. Thus, the selection was carried out, and then carefully studied the sources of radiation, that will be used for calibration of polarimeters. More information on this work expounded in the report. References. 1. P. Nevodovskyi, O. Morozhenko, A. Vidmachenko, O. Ivakhiv, M. Geraimchuk, O. Zbrutskyi. Tiny Ultraviolet Polarimeter for Earth Stratosphere from Space Investigation // Proceedings of 8th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS'2015). 24-26 September 2015, Proceedings. Warsaw, Poland. Vol.81, p. 28-32. 2. Nevodovsksiy P. V., Morozhenko A. V

  2. Measurement of nonvolatile particle number size distribution

    NASA Astrophysics Data System (ADS)

    Gkatzelis, G. I.; Papanastasiou, D. K.; Florou, K.; Kaltsonoudis, C.; Louvaris, E.; Pandis, S. N.

    2016-01-01

    An experimental methodology was developed to measure the nonvolatile particle number concentration using a thermodenuder (TD). The TD was coupled with a high-resolution time-of-flight aerosol mass spectrometer, measuring the chemical composition and mass size distribution of the submicrometer aerosol and a scanning mobility particle sizer (SMPS) that provided the number size distribution of the aerosol in the range from 10 to 500 nm. The method was evaluated with a set of smog chamber experiments and achieved almost complete evaporation (> 98 %) of secondary organic as well as freshly nucleated particles, using a TD temperature of 400 °C and a centerline residence time of 15 s. This experimental approach was applied in a winter field campaign in Athens and provided a direct measurement of number concentration and size distribution for particles emitted from major pollution sources. During periods in which the contribution of biomass burning sources was dominant, more than 80 % of particle number concentration remained after passing through the thermodenuder, suggesting that nearly all biomass burning particles had a nonvolatile core. These remaining particles consisted mostly of black carbon (60 % mass contribution) and organic aerosol (OA; 40 %). Organics that had not evaporated through the TD were mostly biomass burning OA (BBOA) and oxygenated OA (OOA) as determined from AMS source apportionment analysis. For periods during which traffic contribution was dominant 50-60 % of the particles had a nonvolatile core while the rest evaporated at 400 °C. The remaining particle mass consisted mostly of black carbon with an 80 % contribution, while OA was responsible for another 15-20 %. Organics were mostly hydrocarbon-like OA (HOA) and OOA. These results suggest that even at 400 °C some fraction of the OA does not evaporate from particles emitted from common combustion processes, such as biomass burning and car engines, indicating that a fraction of this type of OA

  3. Biases in field measurements of ice nuclei concentrations

    NASA Astrophysics Data System (ADS)

    Garimella, S.; Voigtländer, J.; Kulkarni, G.; Stratmann, F.; Cziczo, D. J.

    2015-12-01

    Ice nuclei (IN) play an important role in the climate system by influencing cloud properties, precipitation, and radiative transfer. Despite their importance, there are significant uncertainties in estimating IN concentrations because of the complexities of atmospheric ice nucleation processes. Field measurements of IN concentrations with Continuous Flow Diffusion Chamber (CFDC) IN counters have been vital to constrain IN number concentrations and have led to various parameterizations of IN number vs. temperature and particle concentration. These parameterizations are used in many global climate models, which are very sensitive to the treatment of cloud microphysics. However, due to non-idealities in CFDC behavior, especially at high relative humidity, many of these measurements are likely biased too low. In this study, the extent of this low bias is examined with laboratory experiments at a variety of instrument conditions using the SPectrometer for Ice Nucleation, a commercially-available CFDC-style chamber. These laboratory results are compared to theoretical calculations and computational fluid dynamics models to map the variability of this bias as a function of chamber temperature and relative humidity.

  4. Factors governing particle number emissions in a waste-to-energy plant.

    PubMed

    Ozgen, Senem; Cernuschi, Stefano; Giugliano, Michele

    2015-05-01

    Particle number concentration and size distribution measurements were performed on the stack gas of a waste-to-energy plant which co-incinerates municipal solid waste, sewage sludge and clinical waste in two lines. Average total number of particles was found to be 4.0·10(5)cm(-3) and 1.9·10(5)cm(-3) for the line equipped with a wet flue gas cleaning process and a dry cleaning system, respectively. Ultrafine particles (dp<100nm) accounted for about 97% of total number concentration for both lines, whereas the nanoparticle (dp<50nm) contribution differed slightly between the lines (87% and 84%). The experimental data is explored statistically through some multivariate pattern identifying methods such as factor analysis and cluster analysis to help the interpretation of the results regarding the origin of the particles in the flue gas with the objective of determining the factors governing the particle number emissions. The higher moisture of the flue gas in the wet cleaning process was found to increase the particle number emissions on average by a factor of about 2 due to increased secondary formation of nanoparticles through nucleation of gaseous precursors such as sulfuric acid, ammonia and water. The influence of flue gas dilution and cooling monitored through the variation of the sampling conditions also confirms the potential effect of the secondary new particle formation in increasing the particle number emissions. This finding shows the importance of reporting the experimental conditions in detail to enable the comparison and interpretation of particle number emissions. Regarding the fuel characteristics no difference was observed in terms of particle number concentration and size distributions between the clinical waste feed and the municipal solid waste co-incineration with sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Temporal evolution of ultrafine particles and of alveolar deposited surface area from main indoor combustion and non-combustion sources in a model room.

    PubMed

    Manigrasso, Maurizio; Vitali, Matteo; Protano, Carmela; Avino, Pasquale

    2017-11-15

    Aerosol number size distributions, PM mass concentrations, alveolar deposited surface areas (ADSAs) and VOC concentrations were measured in a model room when aerosol was emitted by sources frequently encountered in indoor environments. Both combustion and non-combustion sources were considered. The most intense aerosol emission occurred when combustion sources were active (as high as 4.1×10 7 particlescm -3 for two meat grilling sessions; the first with exhaust ventilation, the second without). An intense spike generation of nucleation particles occurred when appliances equipped with brush electric motors were operating (as high as 10 6 particlescm -3 on switching on an electric drill). Average UFP increments over the background value were highest for electric appliances (5-12%) and lowest for combustion sources (as low as -24% for tobacco cigarette smoke). In contrast, average increments in ADSA were highest for combustion sources (as high as 3.2×10 3 μm 2 cm -3 for meat grilling without exhaust ventilation) and lowest for electric appliances (20-90μm 2 cm -3 ). The health relevance of such particles is associated to their ability to penetrate cellular structures and elicit inflammatory effects mediated through oxidative stress in a way dependent on their surface area. The highest VOC concentrations were measured (PID probe) for cigarette smoke (8ppm) and spray air freshener (10ppm). The highest PM mass concentration (PM 1 ) was measured for citronella candle burning (as high as 7.6mgm -3 ). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Variability of air ion concentrations in urban Paris

    NASA Astrophysics Data System (ADS)

    Dos Santos, V. N.; Herrmann, E.; Manninen, H. E.; Hussein, T.; Hakala, J.; Nieminen, T.; Aalto, P. P.; Merkel, M.; Wiedensohler, A.; Kulmala, M.; Petäjä, T.; Hämeri, K.

    2015-12-01

    Air ion concentrations influence new particle formation and consequently the global aerosol as potential cloud condensation nuclei. We aimed to evaluate air ion concentrations and characteristics of new particle formation events (NPF) in the megacity of Paris, France, within the MEGAPOLI (Megacities: Emissions, urban, regional and Global Atmospheric Pollution and climate effects, and Integrated tools for assessment and mitigation) project. We measured air ion number size distributions (0.8-42 nm) with an air ion spectrometer and fine particle number concentrations (> 6 nm) with a twin differential mobility particle sizer in an urban site of Paris between 26 June 2009 and 4 October 2010. Air ions were size classified as small (0.8-2 nm), intermediate (2-7 nm), and large (7-20 nm). The median concentrations of small and large ions were 670 and 680 cm-3, respectively, (sum of positive and negative polarities), whereas the median concentration of intermediate ions was only 20 cm-3, as these ions were mostly present during new particle formation bursts, i.e. when gas-to-particle conversion produced fresh aerosol particles from gas phase precursors. During peaks in traffic-related particle number, the concentrations of small and intermediate ions decreased, whereas the concentrations of large ions increased. Seasonal variations affected the ion population differently, with respect to their size and polarity. NPF was observed in 13 % of the days, being most frequent in spring and late summer (April, May, July, and August). The results also suggest that NPF was favoured on the weekends in comparison to workdays, likely due to the lower levels of condensation sinks in the mornings of weekends (CS weekdays 09:00: 18 × 10-3 s-1; CS weekend 09:00: 8 × 10-3 s-1). The median growth rates (GR) of ions during the NPF events varied between 3 and 7 nm h-1, increasing with the ion size and being higher on workdays than on weekends for intermediate and large ions. The median GR of

  7. Long-term observations of tropospheric particle number size distributions and equivalent black carbon mass concentrations in the German Ultrafine Aerosol Network (GUAN)

    NASA Astrophysics Data System (ADS)

    Birmili, W.; Weinhold, K.; Merkel, M.; Rasch, F.; Sonntag, A.; Wiedensohler, A.; Bastian, S.; Schladitz, A.; Löschau, G.; Cyrys, J.; Pitz, M.; Gu, J.; Kusch, T.; Flentje, H.; Quass, U.; Kaminski, H.; Kuhlbusch, T. A. J.; Meinhardt, F.; Schwerin, A.; Bath, O.; Ries, L.; Wirtz, K.; Fiebig, M.

    2015-11-01

    The German Ultrafine Aerosol Network (GUAN) is a cooperative atmospheric observation network, which aims at improving the scientific understanding of aerosol-related effects in the troposphere. The network addresses research questions dedicated to both, climate and health related effects. GUAN's core activity has been the continuous collection of tropospheric particle number size distributions and black carbon mass concentrations at seventeen observation sites in Germany. These sites cover various environmental settings including urban traffic, urban background, rural background, and Alpine mountains. In association with partner projects, GUAN has implemented a high degree of harmonisation of instrumentation, operating procedures, and data evaluation procedures. The quality of the measurement data is assured by laboratory intercomparisons as well as on-site comparisons with reference instruments. This paper describes the measurement sites, instrumentation, quality assurance and data evaluation procedures in the network as well as the EBAS repository, where the data sets can be obtained (doi:10.5072/guan).

  8. Long-term observations of tropospheric particle number size distributions and equivalent black carbon mass concentrations in the German Ultrafine Aerosol Network (GUAN)

    NASA Astrophysics Data System (ADS)

    Birmili, Wolfram; Weinhold, Kay; Rasch, Fabian; Sonntag, André; Sun, Jia; Merkel, Maik; Wiedensohler, Alfred; Bastian, Susanne; Schladitz, Alexander; Löschau, Gunter; Cyrys, Josef; Pitz, Mike; Gu, Jianwei; Kusch, Thomas; Flentje, Harald; Quass, Ulrich; Kaminski, Heinz; Kuhlbusch, Thomas A. J.; Meinhardt, Frank; Schwerin, Andreas; Bath, Olaf; Ries, Ludwig; Gerwig, Holger; Wirtz, Klaus; Fiebig, Markus

    2016-08-01

    The German Ultrafine Aerosol Network (GUAN) is a cooperative atmospheric observation network, which aims at improving the scientific understanding of aerosol-related effects in the troposphere. The network addresses research questions dedicated to both climate- and health-related effects. GUAN's core activity has been the continuous collection of tropospheric particle number size distributions and black carbon mass concentrations at 17 observation sites in Germany. These sites cover various environmental settings including urban traffic, urban background, rural background, and Alpine mountains. In association with partner projects, GUAN has implemented a high degree of harmonisation of instrumentation, operating procedures, and data evaluation procedures. The quality of the measurement data is assured by laboratory intercomparisons as well as on-site comparisons with reference instruments. This paper describes the measurement sites, instrumentation, quality assurance, and data evaluation procedures in the network as well as the EBAS repository, where the data sets can be obtained (doi:10.5072/guan).

  9. Number of hummingbird visits determines flower mite abundance on hummingbird feeders.

    PubMed

    Márquez-Luna, Ubaldo; Vázquez González, María Magdalena; Castellanos, Ignacio; Ortiz-Pulido, Raúl

    2016-08-01

    Members of several genera of mites from the family Melicharidae (Mesostigmata) use hummingbirds as transport host to move from flower to flower, where they feed on pollen and nectar. The factors that influence hummingbird flower mite abundance on host plant flowers are not currently known. Here we tested whether hummingbird flower mite abundance on an artificial nectar source is determined by number of hummingbird visits, nectar energy content or species richness of visiting hummingbirds. We conducted experiments employing hummingbird feeders with sucrose solutions of low, medium, and high energy concentrations, placed in a xeric shrubland. In the first experiment, we recorded the number of visiting hummingbirds and the number of visiting hummingbird species, as well as the abundance of hummingbird flower mites on each feeder. Feeders with the highest sucrose concentration had the most hummingbird visits and the highest flower mite abundances; however, there was no significant effect of hummingbird species richness on mite abundance. In the second experiment, we recorded flower mite abundance on feeders after we standardized the number of hummingbird visits to them. Abundance of flower mites did not differ significantly between feeders when we controlled for hummingbird visits. Our results suggest that nectar energy concentration determines hummingbird visits, which in turn determines flower mite abundance in our feeders. Our results do not support the hypothesis that mites descend from hummingbird nostrils more on richer nectar sources; however, it does not preclude the possibility that flower mites select for nectar concentration at other spatial and temporal scales.

  10. Ice-nucleating particle concentrations unaffected by urban air pollution in Beijing, China

    NASA Astrophysics Data System (ADS)

    Chen, Jie; Wu, Zhijun; Augustin-Bauditz, Stefanie; Grawe, Sarah; Hartmann, Markus; Pei, Xiangyu; Liu, Zirui; Ji, Dongsheng; Wex, Heike

    2018-03-01

    Exceedingly high levels of PM2.5 with complex chemical composition occur frequently in China. It has been speculated whether anthropogenic PM2.5 may significantly contribute to ice-nucleating particles (INP). However, few studies have focused on the ice-nucleating properties of urban particles. In this work, two ice-nucleating droplet arrays have been used to determine the atmospheric number concentration of INP (NINP) in the range from -6 to -25 °C in Beijing. No correlations between NINP and either PM2.5 or black carbon mass concentrations were found, although both varied by more than a factor of 30 during the sampling period. Similarly, there were no correlations between NINP and either total particle number concentration or number concentrations for particles with diameters > 500 nm. Furthermore, there was no clear difference between day and night samples. All these results indicate that Beijing air pollution did not increase or decrease INP concentrations in the examined temperature range above values observed in nonurban areas; hence, the background INP concentrations might not be anthropogenically influenced as far as urban air pollution is concerned, at least in the examined temperature range.

  11. Atmospheric CO2 Concentrations from Aircraft for 1972-1981, CSIRO Monitoring Program

    DOE Data Explorer

    Beardsmore, David J. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Victoria, Australia; Pearman, Graeme I. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Victoria, Australia

    2012-01-01

    From 1972 through 1981, air samples were collected in glass flasks from aircraft at a variety of latitudes and altitudes over Australia, New Zealand, and Antarctica. The samples were analyzed for CO2 concentrations with nondispersive infrared gas analysis. The resulting data contain the sampling dates, type of aircraft, flight number, flask identification number, sampling time, geographic sector, distance in kilometers from the listed distance measuring equipment (DME) station, station number of the radio navigation distance measuring equipment, altitude of the aircraft above mean sea level, sample analysis date, flask pressure, tertiary standards used for the analysis, analyzer used, and CO2 concentration. These data represent the first published record of CO2 concentrations in the Southern Hemisphere expressed in the WMO 1981 CO2 Calibration Scale and provide a precise record of atmospheric CO2 concentrations in the troposphere and lower stratosphere over Australia and New Zealand.

  12. Global Civil Aviation Black Carbon Particle Mass and Number Emissions

    NASA Astrophysics Data System (ADS)

    Stettler, M. E. J.

    2015-12-01

    Black carbon (BC) is a product of incomplete combustion emitted by aircraft engines. In the atmosphere, BC particles strongly absorb incoming solar radiation and influence cloud formation processes leading to highly uncertain, but likely net positive warming of the earth's atmosphere. At cruise altitude, BC particle number emissions can influence the concentration of ice nuclei that can lead to contrail formation, with significant and highly uncertainty climate impacts. BC particles emitted by aircraft engines also degrade air quality in the vicinity of airports and globally. A significant contribution to the uncertainty in environmental impacts of aviation BC emissions is the uncertainty in emissions inventories. Previous work has shown that global aviation BC mass emissions are likely to have been underestimated by a factor of three. In this study, we present an updated global BC particle number inventory and evaluate parameters that contribute to uncertainty using global sensitivity analysis techniques. The method of calculating particle number from mass utilises a description of the mobility of fractal aggregates and uses the geometric mean diameter, geometric standard deviation, mass-mobility exponent, primary particle diameter and material density to relate the particle number concentration to the total mass concentration. Model results show good agreement with existing measurements of aircraft BC emissions at ground level and at cruise altitude. It is hoped that the results of this study can be applied to estimate direct and indirect climate impacts of aviation BC emissions in future studies.

  13. A plane wave generation method by wave number domain point focusing.

    PubMed

    Chang, Ji-Ho; Choi, Jung-Woo; Kim, Yang-Hann

    2010-11-01

    A method for generation of a wave-field that is a plane wave is described. This method uses an array of loudspeakers phased so that the field in the wave-number domain is nearly concentrated at a point, this point being at the wave-number vector of the desired plane wave. The method described here for such a wave-number concentration makes use of an expansion in spherical harmonics, and requires a relatively small number of measurement points for a good approximate achievement of a plane wave. The measurement points are on a spherical surface surrounding the array of loudspeakers. The input signals for the individual loudspeakers can be derived without a matrix inversion or without explicit assumptions about the loudspeakers. The mathematical development involves spherical harmonics and three-dimensional Fourier transforms. Some numerical examples are given, with various assumptions concerning the nature of the loudspeakers, that support the premise that the method described in the present paper may be useful in applications.

  14. Fecal and urinary N-methylhistamine concentrations in dogs with chronic gastrointestinal disease.

    PubMed

    Berghoff, Nora; Hill, Steve; Parnell, Nolie K; Mansell, Joanne; Suchodolski, Jan S; Steiner, Jörg M

    2014-09-01

    Due to their ability to release inflammatory mediators, such as histamine, mast cells are potentially important in gastrointestinal disease. The purpose of this study was to measure N-methylhistamine (NMH), a histamine metabolite, in fecal and urine samples from dogs with chronic gastrointestinal disease. Fecal and urinary NMH concentrations were compared between dogs with chronic gastrointestinal disease and control dogs, and/or to control ranges. Correlation between fecal and urinary NMH concentrations, serum C-reactive protein (CRP) concentration, the clinical disease activity index (CCECAI), and gastrointestinal mucosal mast cell numbers (where available) in dogs with gastrointestinal disease was evaluated. Seven of 16 dogs with gastrointestinal disease had increased urinary or fecal NMH concentrations, but there was no correlation between NMH concentrations and the CCECAI or mucosal mast cells numbers. Urinary NMH concentrations were positively associated with histological grading and serum CRP concentrations. The lack of correlation between NMH concentrations and the CCECAI suggests that NMH may not be a good marker for clinical disease activity in dogs as determined by the CCECAI. Based on their association with severity of intestinal mucosal inflammation, urinary NMH concentrations may potentially have clinical utility as a marker of intestinal inflammation in certain groups of dogs with chronic gastrointestinal disease, but future studies in a larger number of dogs are necessary to further characterize the role of mast cell-mediated inflammation in dogs with chronic gastrointestinal disease. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. A CFD modeling study in an urban street canyon for ultrafine particles and population exposure: The intake fraction approach.

    PubMed

    Habilomatis, George; Chaloulakou, Archontoula

    2015-10-15

    Air quality in street canyons is of major importance, since the highest pollution levels are often encountered in these microenvironments. The canyon effect (reduced natural ventilation) makes them "hot spots" for particulate pollution contributing to adverse health effects for the exposed population. In this study we tried to characterize the influence of UFP (ultrafine particle) emissions from traffic on population exposure in an urban street canyon, by applying the intake fraction (iF) approach. One month long measurements of UFP levels have been monitored and used for the need of this study. We applied a three dimensional computational fluid dynamic (CFD) model based on real measurements for the simulation of UFP levels. We used infiltration factors, evaluated on a daily basis for the under study area, to estimate the indoor UFP levels. As a result the intake fraction for the pedestrians, residents and office workers is in the range of (1E-5)-(1E-4). The street canyon is mostly residential justifying partially the higher value of intake fraction for residents (1E-4). The above iF value is on the same order of magnitude with the corresponding one evaluated in a relative street canyon study. The total iF value in this microenvironment is one order of magnitude higher than ours, explained partially by the different use and activities. Two specific applications of iF to assess prioritization among emission sources and environmental justice issues are also examined. We ran a scenario with diesel and gasoline cars and diesel fueled vehicle seems to be a target source to improve overall iF. Our application focus on a small residential area, typical of urban central Athens, in order to evaluate high resolution iF. The significance of source-exposure relationship study in a micro scale is emphasized by recent research. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Gene expression profile in circulating mononuclear cells after exposure to ultrafine carbon particles

    PubMed Central

    Huang, Yuh-Chin T.; Schmitt, Michael; Yang, Zhonghui; Que, Loretta G.; Stewart, Judith C.; Frampton, Mark W.; Devlin, Robert B.

    2013-01-01

    Context Exposure to particulate matter (PM) is associated with systemic health effects, but the cellular and molecular mechanisms are unclear. Objective We hypothesized that, if circulating mononuclear cells play an important role in mediating systemic effects of PM, they would show gene expression changes following exposure. Materials and methods Peripheral blood samples were collected before (0 hour) and at 24 hours after exposure from healthy subjects who participated in previous controlled exposures to ultrafine carbon particles (UFP, 50 μg/m3) or filtered air (FA)(n = 3 each). RNA from mononuclear cell fraction (>85% lymphocytes) was extracted, amplified and hybridized to Affymetrix HU133 plus 2 microarrays. Results We identified 1713 genes (UFP 24 hours vs. FA 0 and 24 hours, p < 0.05, FDR 0.01). The top 10 upregulated genes (fold) were CDKN1C (1.86), ZNF12 (1.83), SRGAP2 (1.82), FYB (1.79), LSM14B (1.79), CD93 (1.76), NCSTN (1.70), DUSP6 (1.69), TACC1 (1.68) and H2AFY (1.68). Upregulation of CDKN1C and SRGAP2 was confirmed by RT-PCR using samples from additional 5 subjects exposed to FA and UFP. We entered 1020 genes with a ratio >1.1 or <−1.1 into the Ingenuity Pathway Analysis and identified many canonical pathways related to inflammation, tissue growth and host defense against environmental insults, including IGF-1 signaling, insulin receptor signaling and NRF2-mediated oxidative stress response pathway. Discussion and conclusions Two-hour exposures to UFP produced gene expression changes in circulating mononuclear cells. These gene changes provide biologically plausible links to PM-induced systemic health effects, especially those in the cardiovascular system and glucose metabolism. PMID:20507211

  17. Black Carbon Particle Number Distribution Measurements during the ATHENS-2013 Winter Campaign

    NASA Astrophysics Data System (ADS)

    Gkatzelis, Georgios; Papanastasiou, Dimitris; Florou, Kalliopi; Kaltsonoudis, Christos; Louvaris, Eyaggelos; Bezentakos, Spiridon; Biskos, Georgios; Pandis, Spuros

    2014-05-01

    Black Carbon (BC) particles emitted by anthropogenic sources play an important role both in climate change and in air quality degradation. Open burning in forests and savannas, combustion of diesel and solid fuels for cooking and heating in homes represent the majority of BC emissions. Earlier work has focused on the BC atmospheric direct radiative forcing that is mostly related to its mass concentration and optical properties of the corresponding particles. A variety of measurement techniques are used to measure the mass concentration of BC by taking advantage of its optical or physical properties. Moreover, the carbonaceous particles containing BC are also important for the indirect forcing of climate. This effect is mostly related to the number concentration of BC particles. The number distribution of BC particles especially below 100 nm is quite uncertain due to limitations of the existing measurement techniques. In this work we employed a thermodenuder-based method as an approach for the measurement of the BC number distribution. More specifically, we combined a thermodenuder (TD) operating at temperatures up to 300 ° C, with a Scanning Mobility Particle Sizer (SMPS) and a High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF AMS). Aerosol size and composition measurements were carried out both at ambient and at elevated TD temperatures in Athens field campaign during January and February of 2013. In parallel, a Multi-Angle Absorption Photometer (MAAP) provided information about the BC mass concentration while a Hygroscopic Tandem Differential Mobility Analyzer (HTDMA) measured the mixing state and the hygroscopicity of the particles as a function of their size. These measurements were then combined to estimate the number concentration of BC particles. Our analysis focused on different periods during the study. During some of them one source dominated the carbonaceous aerosol concentration. Such periods included rush hour traffic, nighttime wood

  18. Mass, surface area and number metrics in diesel occupational exposure assessment.

    PubMed

    Ramachandran, Gurumurthy; Paulsen, Dwane; Watts, Winthrop; Kittelson, David

    2005-07-01

    While diesel aerosol exposure assessment has traditionally been based on the mass concentration metric, recent studies have suggested that particle number and surface area concentrations may be more health-relevant. In this study, we evaluated the exposures of three occupational groups-bus drivers, parking garage attendants, and bus mechanics-using the mass concentration of elemental carbon (EC) as well as surface area and number concentrations. These occupational groups are exposed to mixtures of diesel and gasoline exhaust on a regular basis in various ratios. The three groups had significantly different exposures to workshift TWA EC with the highest levels observed in the bus garage mechanics and the lowest levels in the parking ramp booth attendants. In terms of surface area, parking ramp attendants had significantly greater exposures than bus garage mechanics, who in turn had significantly greater exposures than bus drivers. In terms of number concentrations, the exposures of garage mechanics exceeded those of ramp booth attendants by a factor of 5-6. Depending on the exposure metric chosen, the three occupational groups had quite different exposure rankings. This illustrates the importance of the choice of exposure metric in epidemiological studies. If these three occupational groups were part of an epidemiological study, depending on the metric used, they may or may not be part of the same similarly exposed group (SEG). The exposure rankings (e.g., low, medium, or high) of the three groups also changes with the metric used. If the incorrect metric is used, significant misclassification errors may occur.

  19. Nanomaterials Versus Ambient Ultrafine Particles: An Opportunity to Exchange Toxicology Knowledge

    PubMed Central

    Miller, Mark R.; Clift, Martin J.D.; Elder, Alison; Mills, Nicholas L.; Møller, Peter; Schins, Roel P.F.; Vogel, Ulla; Kreyling, Wolfgang G.; Alstrup Jensen, Keld; Kuhlbusch, Thomas A.J.; Schwarze, Per E.; Hoet, Peter; Pietroiusti, Antonio; De Vizcaya-Ruiz, Andrea; Baeza-Squiban, Armelle; Teixeira, João Paulo; Tran, C. Lang; Cassee, Flemming R.

    2017-01-01

    Background: A rich body of literature exists that has demonstrated adverse human health effects following exposure to ambient air particulate matter (PM), and there is strong support for an important role of ultrafine (nanosized) particles. At present, relatively few human health or epidemiology data exist for engineered nanomaterials (NMs) despite clear parallels in their physicochemical properties and biological actions in in vitro models. Objectives: NMs are available with a range of physicochemical characteristics, which allows a more systematic toxicological analysis. Therefore, the study of ultrafine particles (UFP, <100 nm in diameter) provides an opportunity to identify plausible health effects for NMs, and the study of NMs provides an opportunity to facilitate the understanding of the mechanism of toxicity of UFP. Methods: A workshop of experts systematically analyzed the available information and identified 19 key lessons that can facilitate knowledge exchange between these discipline areas. Discussion: Key lessons range from the availability of specific techniques and standard protocols for physicochemical characterization and toxicology assessment to understanding and defining dose and the molecular mechanisms of toxicity. This review identifies a number of key areas in which additional research prioritization would facilitate both research fields simultaneously. Conclusion: There is now an opportunity to apply knowledge from NM toxicology and use it to better inform PM health risk research and vice versa. https://doi.org/10.1289/EHP424 PMID:29017987

  20. Nanomaterials Versus Ambient Ultrafine Particles: An Opportunity to Exchange Toxicology Knowledge.

    PubMed

    Stone, Vicki; Miller, Mark R; Clift, Martin J D; Elder, Alison; Mills, Nicholas L; Møller, Peter; Schins, Roel P F; Vogel, Ulla; Kreyling, Wolfgang G; Alstrup Jensen, Keld; Kuhlbusch, Thomas A J; Schwarze, Per E; Hoet, Peter; Pietroiusti, Antonio; De Vizcaya-Ruiz, Andrea; Baeza-Squiban, Armelle; Teixeira, João Paulo; Tran, C Lang; Cassee, Flemming R

    2017-10-10

    A rich body of literature exists that has demonstrated adverse human health effects following exposure to ambient air particulate matter (PM), and there is strong support for an important role of ultrafine (nanosized) particles. At present, relatively few human health or epidemiology data exist for engineered nanomaterials (NMs) despite clear parallels in their physicochemical properties and biological actions in in vitro models. NMs are available with a range of physicochemical characteristics, which allows a more systematic toxicological analysis. Therefore, the study of ultrafine particles (UFP, <100 nm in diameter) provides an opportunity to identify plausible health effects for NMs, and the study of NMs provides an opportunity to facilitate the understanding of the mechanism of toxicity of UFP. A workshop of experts systematically analyzed the available information and identified 19 key lessons that can facilitate knowledge exchange between these discipline areas. Key lessons range from the availability of specific techniques and standard protocols for physicochemical characterization and toxicology assessment to understanding and defining dose and the molecular mechanisms of toxicity. This review identifies a number of key areas in which additional research prioritization would facilitate both research fields simultaneously. There is now an opportunity to apply knowledge from NM toxicology and use it to better inform PM health risk research and vice versa. https://doi.org/10.1289/EHP424.

  1. SLTCAP: A Simple Method for Calculating the Number of Ions Needed for MD Simulation.

    PubMed

    Schmit, Jeremy D; Kariyawasam, Nilusha L; Needham, Vince; Smith, Paul E

    2018-04-10

    An accurate depiction of electrostatic interactions in molecular dynamics requires the correct number of ions in the simulation box to capture screening effects. However, the number of ions that should be added to the box is seldom given by the bulk salt concentration because a charged biomolecule solute will perturb the local solvent environment. We present a simple method for calculating the number of ions that requires only the total solute charge, solvent volume, and bulk salt concentration as inputs. We show that the most commonly used method for adding salt to a simulation results in an effective salt concentration that is too high. These findings are confirmed using simulations of lysozyme. We have established a web server where these calculations can be readily performed to aid simulation setup.

  2. Description and measurement of concentration problems in depressed patients.

    PubMed

    Watts, F N; Sharrock, R

    1985-05-01

    Depressed patients commonly complain of concentration problems, yet these have seldom been the focus of systematic investigation. A structured interview about concentration problems was administered to a group of relatively severely depressed patients. Problems in reading and watching television were the most common, and were highly correlated with each other. Direct report of the number of concentration lapses on a reading task was the most generally satisfactory task-performance correlate of complaints of reading/TV concentration problems. Evidence both from this task and from the interview suggests that depressive concentration problems may often be due to 'mind-wandering'. The correlations with concentration problems with the severity and endogeneity of depression and with state anxiety were generally similar.

  3. A developmental basis for stochasticity in floral organ numbers

    PubMed Central

    Kitazawa, Miho S.; Fujimoto, Koichi

    2014-01-01

    Stochasticity ubiquitously inevitably appears at all levels from molecular traits to multicellular, morphological traits. Intrinsic stochasticity in biochemical reactions underlies the typical intercellular distributions of chemical concentrations, e.g., morphogen gradients, which can give rise to stochastic morphogenesis. While the universal statistics and mechanisms underlying the stochasticity at the biochemical level have been widely analyzed, those at the morphological level have not. Such morphological stochasticity is found in foral organ numbers. Although the floral organ number is a hallmark of floral species, it can distribute stochastically even within an individual plant. The probability distribution of the floral organ number within a population is usually asymmetric, i.e., it is more likely to increase rather than decrease from the modal value, or vice versa. We combined field observations, statistical analysis, and mathematical modeling to study the developmental basis of the variation in floral organ numbers among 50 species mainly from Ranunculaceae and several other families from core eudicots. We compared six hypothetical mechanisms and found that a modified error function reproduced much of the asymmetric variation found in eudicot floral organ numbers. The error function is derived from mathematical modeling of floral organ positioning, and its parameters represent measurable distances in the floral bud morphologies. The model predicts two developmental sources of the organ-number distributions: stochastic shifts in the expression boundaries of homeotic genes and a semi-concentric (whorled-type) organ arrangement. Other models species- or organ-specifically reproduced different types of distributions that reflect different developmental processes. The organ-number variation could be an indicator of stochasticity in organ fate determination and organ positioning. PMID:25404932

  4. Traffic-related air pollution in the community of San Ysidro, CA, in relation to northbound vehicle wait times at the US-Mexico border Port of Entry

    NASA Astrophysics Data System (ADS)

    Quintana, Penelope J. E.; Dumbauld, Jill J.; Garnica, Lynelle; Chowdhury, M. Zohir; Velascosoltero, José; Mota-Raigoza, Arturo; Flores, David; Rodríguez, Edgar; Panagon, Nicolas; Gamble, Jamison; Irby, Travis; Tran, Cuong; Elder, John; Galaviz, Vanessa E.; Hoffman, Lisa; Zavala, Miguel; Molina, Luisa T.

    2014-05-01

    The San Diego/Tijuana US-Mexico border crossing at the San Ysidro Port of Entry (POE) is the world's busiest international land border crossing (GSA, 2013). San Ysidro, California, is the US community immediately adjacent to the border crossing. More than 90% of San Ysidro residents are Hispanic, and the average household income is less than 60% of the San Diego regional average. This study investigated the San Ysidro POE as a source of traffic-related air pollutants in San Ysidro, especially in relation to wind direction and northbound vehicle wait times. The pollutants ultrafine particulate matter (UFP), black carbon (BC), and particulate matter <2.5 μm in diameter (PM2.5) were periodically sampled through the course of 2010 at four rooftop locations: one commercial establishment near the POE, two elementary schools in San Ysidro, and a coastal estuary reference site. Weather data from two nearby sites and northbound border wait times were also collected. Results indicate consistently higher daytime BC and UFP concentrations at the measurement sites near the POE. Pollution concentrations were higher during low wind speeds or when wind was blowing from the POE towards San Ysidro. In February, March and November measurements, black carbon pollution appeared to be significantly positively associated with the POE northbound wait times when the wind direction was blowing from the POE towards San Ysidro or during low wind speeds, but not when the wind direction was from the west/northwest towards the POE. This pilot study is the first to investigate the potential effect of the POE, especially the long northbound traffic delays, on the nearby community of San Ysidro. Disparities in traffic exposures are an environmental justice issue and this should be taken into account during planning and operation of POEs.

  5. Complex numbers in chemometrics: examples from multivariate impedance measurements on lipid monolayers.

    PubMed

    Geladi, Paul; Nelson, Andrew; Lindholm-Sethson, Britta

    2007-07-09

    Electrical impedance gives multivariate complex number data as results. Two examples of multivariate electrical impedance data measured on lipid monolayers in different solutions give rise to matrices (16x50 and 38x50) of complex numbers. Multivariate data analysis by principal component analysis (PCA) or singular value decomposition (SVD) can be used for complex data and the necessary equations are given. The scores and loadings obtained are vectors of complex numbers. It is shown that the complex number PCA and SVD are better at concentrating information in a few components than the naïve juxtaposition method and that Argand diagrams can replace score and loading plots. Different concentrations of Magainin and Gramicidin A give different responses and also the role of the electrolyte medium can be studied. An interaction of Gramicidin A in the solution with the monolayer over time can be observed.

  6. Anaemia in the sow: a cohort study to assess factors with an impact on haemoglobin concentration, and the influence of haemoglobin concentration on the reproductive performance.

    PubMed

    Normand, V; Perrin, H; Auvigne, V; Robert, N; Laval, A

    2012-10-06

    The aim of this study was to conduct a descriptive study of haemoglobin concentration found on high-prolificacy sows, to study the relationship between the concentration of haemoglobin and body reserves, and to determine whether anaemia is a risk factor for reproductive performance. A cohort of 308 sows from seven farms was followed from the last third of gestation to the confirmation of the following gestation. Haemoglobin concentration was assessed at four stages of the reproductive cycle: seven and four weeks before farrowing, a few days and three weeks after farrowing. Backfat thickness (BFT) was measured at parturition. The results were analysed using linear mixed-effect models. The mean haemoglobin concentration was 108.4 g/l. The mean modellised haemoglobin concentration of parity 1 sows with a BFT of 16 mm, sampled seven weeks before farrowing, was 118 g/l. Haemoglobin concentration of sows of parity 6 or higher was 8.0 g/l lower than those of parity 1 sows (95% confidence interval -11.0 to -5.1). Haemoglobin concentration is lower in sows with a lower BFT, whatever parity rank. There is no evidence of a relation between haemoglobin concentration and the number of total born, stillborn or number of piglets alive at three weeks and the next breeding performance.

  7. Performance of school bus retrofit systems: ultrafine particles and other vehicular pollutants.

    PubMed

    Zhang, Qunfang; Zhu, Yifang

    2011-08-01

    This study evaluated the performance of retrofit systems for diesel-powered school buses, a diesel oxidation catalyst (DOC) muffler and a spiracle crankcase filtration system (CFS), regarding ultrafine particles (UFPs) and other air pollutants from tailpipe emissions and inside bus cabins. Tailpipe emissions and in-cabin air pollutant levels were measured before and after retrofitting when the buses were idling and during actual pick-up/drop off routes. Retrofit systems significantly reduced tailpipe emissions with a reduction of 20-94% of total particles with both DOC and CFS installed. However, no unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The AC/fan unit and the surrounding air pollutant concentrations played more important roles for determining the in-cabin air quality of school buses than did retrofit technologies. Although current retrofit systems reduce children's exposure while waiting to board at a bus station, retrofitting by itself does not protect children satisfactorily from in-cabin particle exposures. Turning on the bus engine increased in-cabin UFP levels significantly only when the wind blew from the bus' tailpipe toward its hood with its windows open. This indicated that wind direction and window position are significant factors determining how much self-released tailpipe emissions may penetrate into the bus cabin. The use of an air purifier was found to remove in-cabin particles by up to 50% which might be an alternative short-to-medium term strategy to protect children's health.

  8. Comparative In Vitro Biological Toxicity of Four Kinds of Air Pollution Particles.

    PubMed

    Shin, Han-Jae; Cho, Hyun Gi; Park, Chang Kyun; Park, Ki Hong; Lim, Heung Bin

    2017-10-01

    Accumulating epidemiological evidence indicates that exposure to fine air pollution particles (APPs) is associated with a variety of adverse health effects. However, the exact physiochemical properties and biological toxicities of fine APPs are still not well characterized. We collected four types of fine particle (FP) (diesel exhaust particles [DEPs], natural organic combustion [NOC] ash, synthetic organic combustion [SOC] ash, and yellow sand dust [YSD]) and investigated their physicochemical properties and in vitro biological toxicity. DEPs were almost entirely composed of ultrafine particles (UFPs), while the NOC, SOC, and YSD particles were a mixture of UFPs and FPs. The main elements in the DEPs, NOC ash, SOC ash, and YSD were black carbon, silicon, black carbon, and silicon, respectively. DEPs exhibited dose-dependent mutagenicity even at a low dose in Salmonella typhimurium TA 98 and 100 strains in an Ames test for genotoxicity. However, NOC, SOC, and YSD particles did not show any mutagenicity at high doses. The neutral red uptake assay to test cell viability revealed that DEPs showed dose-dependent potent cytotoxicity even at a low concentration. The toxicity of DEPs was relatively higher than that of NOC, SOC, and YSD particles. Therefore, these results indicate that among the four FPs, DEPs showed the highest in vitro biological toxicity. Additional comprehensive research studies such as chemical analysis and in vivo acute and chronic inhalation toxicity tests are necessary to determine and clarify the effects of this air contaminant on human health.

  9. Contribution of pollen to atmospheric ice nuclei concentrations

    NASA Astrophysics Data System (ADS)

    Hader, J. D.; Wright, T. P.; Petters, M. D.

    2014-06-01

    Recent studies have suggested that the ice-nucleating ability of some types of pollen is derived from non-proteinaceous macromolecules. These macromolecules may become dispersed by the rupturing of the pollen grain during wetting and drying cycles in the atmosphere. If true, this mechanism might prove to be a significant source of ice nuclei (IN) concentrations when pollen is present. Here we test this hypothesis by measuring ambient IN concentrations from the beginning to the end of the 2013 pollen season in Raleigh, North Carolina, USA. Air samples were collected using a swirling aerosol collector twice per week and the solutions were analysed for ice nuclei activity using a droplet freezing assay. Rainwater samples were collected at times when pollen grain number concentrations were near their maximum value and analysed with the drop-freezing assay to compare the potentially enhanced IN concentrations measured near the ground with IN concentrations found aloft. Ambient ice nuclei spectra, defined as the number of ice nuclei per volume of air as a function of temperature, are inferred from the aerosol collector solutions. No general trend was observed between ambient pollen grain counts and observed IN concentrations, suggesting that ice nuclei multiplication via pollen grain rupturing and subsequent release of macromolecules was not prevalent for the pollen types and meteorological conditions typically encountered in the southeastern US. A serendipitously sampled collection after a downpour provided evidence for a rain-induced IN burst with an observed IN concentration of approximately 30 per litre, a 30-fold increase over background concentrations at -20 °C. The onset temperature of freezing for these particles was approximately -12 °C, suggesting that the ice-nucleating particles were biological in origin.

  10. Measurement of non-volatile particle number size distribution

    NASA Astrophysics Data System (ADS)

    Gkatzelis, G. I.; Papanastasiou, D. K.; Florou, K.; Kaltsonoudis, C.; Louvaris, E.; Pandis, S. N.

    2015-06-01

    An experimental methodology was developed to measure the non-volatile particle number concentration using a thermodenuder (TD). The TD was coupled with a high-resolution time-of-flight aerosol mass spectrometer, measuring the chemical composition and mass size distribution of the submicrometer aerosol and a scanning mobility particle sizer (SMPS) that provided the number size distribution of the aerosol in the range from 10 to 500 nm. The method was evaluated with a set of smog chamber experiments and achieved almost complete evaporation (> 98 %) of secondary organic as well as freshly nucleated particles, using a TD temperature of 400 °C and a centerline residence time of 15 s. This experimental approach was applied in a winter field campaign in Athens and provided a direct measurement of number concentration and size distribution for particles emitted from major pollution sources. During periods in which the contribution of biomass burning sources was dominant, more than 80 % of particle number concentration remained after passing through the thermodenuder, suggesting that nearly all biomass burning particles had a non-volatile core. These remaining particles consisted mostly of black carbon (60 % mass contribution) and organic aerosol, OA (40 %). Organics that had not evaporated through the TD were mostly biomass burning OA (BBOA) and oxygenated OA (OOA) as determined from AMS source apportionment analysis. For periods during which traffic contribution was dominant 50-60 % of the particles had a non-volatile core while the rest evaporated at 400 °C. The remaining particle mass consisted mostly of black carbon (BC) with an 80 % contribution, while OA was responsible for another 15-20 %. Organics were mostly hydrocarbon-like OA (HOA) and OOA. These results suggest that even at 400 °C some fraction of the OA does not evaporate from particles emitted from common combustion processes, such as biomass burning and car engines, indicating that a fraction of this type

  11. Galaxy populations in massive galaxy clusters to $z$ = 1.1: Color distribution, concentration, halo occupation number and red sequence fraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennig, C.; Mohr, Joseph J.; Zenteno, A.

    We study the galaxy populations in 74 Sunyaev–Zeldovich effect selected clusters from the South Pole Telescope survey, which have been imaged in the science verification phase of the Dark Energy Survey. The sample extends up to z ~ 1.1 with 4 × 10 14 M⊙ ≤ M200 ≤ 3 × 10 15M⊙. Using the band containing the 4000 Å break and its redward neighbour, we study the colour–magnitude distributions of cluster galaxies to ~m* + 2, finding that: (1)The intrinsic rest frame g – r colour width of the red sequence (RS) population is ~0.03 out to z ~ 0.85 with a preference for an increase to ~0.07 at z = 1, and (2) the prominence of the RS declines beyond z ~ 0.6. The spatial distribution of cluster galaxies is well described by the NFW profile out to 4R200 with a concentration of c g = 3.59more » $$+0.20\\atop{–0.18}$$, 5.37$$+0.27\\atop{-0.24}$$ and 1.38$$+0.21\\atop{-0.19}$$ for the full, the RS and the blue non-RS populations, respectively, but with ~40 per cent to 55 per cent cluster to cluster variation and no statistically significant redshift or mass trends. The number of galaxies within the virial region N200 exhibits a mass trend indicating that the number of galaxies per unit total mass is lower in the most massive clusters, and shows no significant redshift trend. The RS fraction within R200 is (68 ± 3) per cent at z = 0.46, varies from ~55 per cent at z = 1 to ~80 per cent at z = 0.1 and exhibits intrinsic variation among clusters of ~14 per cent. Finally, we discuss a model that suggests that the observed redshift trend in RS fraction favours a transformation time-scale for infalling field galaxies to become RS galaxies of 2–3 Gyr.« less

  12. Galaxy populations in massive galaxy clusters to $z$ = 1.1: Color distribution, concentration, halo occupation number and red sequence fraction

    DOE PAGES

    Hennig, C.; Mohr, Joseph J.; Zenteno, A.; ...

    2017-01-23

    We study the galaxy populations in 74 Sunyaev–Zeldovich effect selected clusters from the South Pole Telescope survey, which have been imaged in the science verification phase of the Dark Energy Survey. The sample extends up to z ~ 1.1 with 4 × 10 14 M⊙ ≤ M200 ≤ 3 × 10 15M⊙. Using the band containing the 4000 Å break and its redward neighbour, we study the colour–magnitude distributions of cluster galaxies to ~m* + 2, finding that: (1)The intrinsic rest frame g – r colour width of the red sequence (RS) population is ~0.03 out to z ~ 0.85 with a preference for an increase to ~0.07 at z = 1, and (2) the prominence of the RS declines beyond z ~ 0.6. The spatial distribution of cluster galaxies is well described by the NFW profile out to 4R200 with a concentration of c g = 3.59more » $$+0.20\\atop{–0.18}$$, 5.37$$+0.27\\atop{-0.24}$$ and 1.38$$+0.21\\atop{-0.19}$$ for the full, the RS and the blue non-RS populations, respectively, but with ~40 per cent to 55 per cent cluster to cluster variation and no statistically significant redshift or mass trends. The number of galaxies within the virial region N200 exhibits a mass trend indicating that the number of galaxies per unit total mass is lower in the most massive clusters, and shows no significant redshift trend. The RS fraction within R200 is (68 ± 3) per cent at z = 0.46, varies from ~55 per cent at z = 1 to ~80 per cent at z = 0.1 and exhibits intrinsic variation among clusters of ~14 per cent. Finally, we discuss a model that suggests that the observed redshift trend in RS fraction favours a transformation time-scale for infalling field galaxies to become RS galaxies of 2–3 Gyr.« less

  13. Equipment Loan for Concentrated PV Cavity Converter (PVCC) Research: Cooperative Research and Development Final Report, CRADA Number CRD-08-285

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Netter, Judy

    2015-07-28

    Interest in High Concentration Photovoltaics (HCPV) for terrestrial applications has significantly grown in recent years. A major driver behind this growth trend is the availability of high efficiency multi-junction (MJ) cells that promise reliable operation under high concentrations (500 to 1000 suns). The primary impact of HCPV on the solar electricity cost is the dramatic reduction in cell cost. For terrestrial HCPV systems, operating at concentrations ≥ 500 suns, the expensive MJ cells are marginally affordable. Most recently, triple-junction test cells have achieved a conversion efficiency of over 40% under concentrated sunlight. Photovoltaic Cavity Converter (PVCC) is a multi-bandgap, highmore » concentration PV device developed by United Innovations, Inc., under subcontract to NREL. The lateral- (2- dimensional) structure of PVCC, as opposed to vertical multi-junction (MJ) structure, helps to circumvent most of the developmental challenges MJ technology has yet to overcome. This CRADA will allow the continued development of this technology by United Innovations. This project was funded by the California Energy Commission and is the second phase of a twopart demonstration program. The key advantage of the design was the use of a PVCC as the receiver. PVCCs efficiently process highly concentrated solar radiation into electricity by recycling photons that are reflected from the surface of the cells. Conventional flat, twodimensional receivers cannot recycle photons and the reflected photons are lost to the conversion process.« less

  14. Effects of turbulence on warm clouds and precipitation with various aerosol concentrations

    NASA Astrophysics Data System (ADS)

    Lee, Hyunho; Baik, Jong-Jin; Han, Ji-Young

    2015-02-01

    This study investigates the effects of turbulence-induced collision enhancement (TICE) on warm clouds and precipitation by changing the cloud condensation nuclei (CCN) number concentration using a two-dimensional dynamic model with bin microphysics. TICE is determined according to the Taylor microscale Reynolds number and the turbulent dissipation rate. The thermodynamic sounding used in this study is characterized by a warm and humid atmosphere with a capping inversion layer, which is suitable for simulating warm clouds. For all CCN concentrations, TICE slightly reduces the liquid water path during the early stage of cloud development and accelerates the onset of surface precipitation. However, changes in the rainwater path and in the amount of surface precipitation that are caused by TICE depend on the CCN concentrations. For high CCN concentrations, the mean cloud drop number concentration (CDNC) decreases and the mean effective radius increases due to TICE. These changes cause an increase in the amount of surface precipitation. However, for low CCN concentrations, changes in the mean CDNC and in the mean effective radius induced by TICE are small and the amount of surface precipitation decreases slightly due to TICE. A decrease in condensation due to the accelerated coalescence between droplets explains the surface precipitation decrease. In addition, an increase in the CCN concentration can lead to an increase in the amount of surface precipitation, and the relationship between the CCN concentration and the amount of surface precipitation is affected by TICE. It is shown that these results depend on the atmospheric relative humidity.

  15. Concentrations of 222Rn and its short-lived decay products at a number of greek radon spas

    NASA Astrophysics Data System (ADS)

    Kritidis, P.; Angelou, P.

    1986-11-01

    A series of measurements has been performed in 9 radon therapy centers in order to determine concentration levels of radon and its decay products in the air and to assess the related personnel and patient annual doses.

  16. Suicides in the Nazi Concentration Camps.

    ERIC Educational Resources Information Center

    Ryn, Zdzislaw

    1986-01-01

    On the basis of psychiatric interviews with 69 former prisoners of the Auschwitz-Birkenau concentration camp, this paper describes the circumstances, motives, and ways of committing suicide in the camp. The interviews made it clear that thousands of prisoners perished by suicide. The number of committed suicides was larger than that of attempted…

  17. Concentration of the Most-Cited Papers in the Scientific Literature: Analysis of Journal Ecosystems

    PubMed Central

    Ioannidis, John P. A.

    2006-01-01

    Background A minority of scientific journals publishes the majority of scientific papers and receives the majority of citations. The extent of concentration of the most influential articles is less well known. Methods/Principal Findings The 100 most-cited papers in the last decade in each of 21 scientific fields were analyzed; fields were considered as ecosystems and their “species” (journal) diversity was evaluated. Only 9% of journals in Journal Citation Reports had published at least one such paper. Among this 9%, half of them had published only one such paper. The number of journals that had published a larger number of most-cited papers decreased exponentially according to a Lotka law. Except for three scientific fields, six journals accounted for 53 to 94 of the 100 most-cited papers in their field. With increasing average number of citations per paper (citation density) in a scientific field, concentration of the most-cited papers in a few journals became even more prominent (p<0.001). Concentration was unrelated to the number of papers published or number of journals available in a scientific field. Multidisciplinary journals accounted for 24% of all most-cited papers, with large variability across fields. The concentration of most-cited papers in multidisciplinary journals was most prominent in fields with high citation density (correlation coefficient 0.70, p<0.001). Multidisciplinary journals had published fewer than eight of the 100 most-cited papers in eight scientific fields (none in two fields). Journals concentrating most-cited original articles often differed from those concentrating most-cited reviews. The concentration of the most-influential papers was stronger than the already prominent concentration of papers published and citations received. Conclusions Despite a plethora of available journals, the most influential papers are extremely concentrated in few journals, especially in fields with high citation density. Existing

  18. Quantification of nanoparticle concentration in colloidal suspensions by a non-destructive optical method

    NASA Astrophysics Data System (ADS)

    Clement, Sandhya; Gardner, Brint; Razali, Wan Aizuddin W.; Coleman, Victoria A.; Jämting, Åsa K.; Catchpoole, Heather J.; Goldys, Ewa M.; Herrmann, Jan; Zvyagin, Andrei

    2017-11-01

    The estimation of nanoparticle number concentration in colloidal suspensions is a prerequisite in many procedures, and in particular in multi-stage, low-yield reactions. Here, we describe a rapid, non-destructive method based on optical extinction and dynamic light scattering (DLS), which combines measurements using common bench-top instrumentation with a numerical algorithm to calculate the particle size distribution (PSD) and concentration. These quantities were derived from Mie theory applied to measurements of the optical extinction spectrum of homogeneous, non-absorbing nanoparticles, and the relative PSD of a colloidal suspension. The work presents an approach to account for PSDs achieved by DLS which, due to the underlying model, may not be representative of the true sample PSD. The presented approach estimates the absolute particle number concentration of samples with mono-, bi-modal and broad size distributions with <50% precision. This provides a convenient and practical solution for number concentration estimation required during many applications of colloidal nanomaterials.

  19. Negative Transference Numbers in Polymer Electrolytes

    NASA Astrophysics Data System (ADS)

    Pesko, Danielle; Timachova, Ksenia; Balsara, Nitash

    Energy density and safety of conventional lithium-ion batteries is limited by the use of flammable organic liquids as a solvent for lithium salts. Polymer electrolytes have the potential to address both limitations. The poor performance of batteries with polymer electrolytes is generally attributed to low ionic conductivity. The purpose of our work is to show that another transport property, the cation transference number, t +, of polymer electrolytes is fundamentally different from that of conventional electrolytes. Our experimental approach, based on concentrated solution theory, indicates that t + of mixtures of poly(ethylene oxide) and LiTFSI salt are negative over most of the accessible concentration window. In contrast, approaches based on dilute solution theory suggest that t + in the same system is positive. In addition to presenting a new approach for determining t +, we also present data obtained from the steady-state current method, pulsed-field-gradient NMR, and the current-interrupt method. Discrepancies between different approaches are resolved. Our work implies that in the absence of concentration gradients, the net fluxes of both cations and anions are directed toward the positive electrode. Conventional liquid electrolytes do not suffer from this constraint.

  20. Localisation of an Unknown Number of Land Mines Using a Network of Vapour Detectors

    PubMed Central

    Chhadé, Hiba Haj; Abdallah, Fahed; Mougharbel, Imad; Gning, Amadou; Julier, Simon; Mihaylova, Lyudmila

    2014-01-01

    We consider the problem of localising an unknown number of land mines using concentration information provided by a wireless sensor network. A number of vapour sensors/detectors, deployed in the region of interest, are able to detect the concentration of the explosive vapours, emanating from buried land mines. The collected data is communicated to a fusion centre. Using a model for the transport of the explosive chemicals in the air, we determine the unknown number of sources using a Principal Component Analysis (PCA)-based technique. We also formulate the inverse problem of determining the positions and emission rates of the land mines using concentration measurements provided by the wireless sensor network. We present a solution for this problem based on a probabilistic Bayesian technique using a Markov chain Monte Carlo sampling scheme, and we compare it to the least squares optimisation approach. Experiments conducted on simulated data show the effectiveness of the proposed approach. PMID:25384008

  1. Fluctuations, Stratification and Stability in a Liquid Fluidized Bed at Low Reynolds Number

    NASA Technical Reports Server (NTRS)

    Segre, P. N.; McClymer, J. P.

    2004-01-01

    The sedimentation dynamics of extremely low polydispersity, non-colloidal, particles are studied in a liquid fluidized bed at low Reynolds number, Re much less than 1. When fluidized, the system reaches a steady state, defined where the local average volume fraction does not vary in time. In steady state, the velocity fluctuations and the particle concentrations are found to strongly depend on height. Using our results, we test a recently developed stability model for steady state sedimentation. The model describes the data well, and shows that in steady state there is a balancing of particle fluxes due to the fluctuations and the concentration gradient. Some results are also presented for the dependence of the concentration gradient in fluidized beds on particle size; the gradients become smaller as the particles become larger and fewer in number.

  2. [Nitrate concentrations in tap water in Spain].

    PubMed

    Vitoria, Isidro; Maraver, Francisco; Sánchez-Valverde, Félix; Armijo, Francisco

    2015-01-01

    To determine nitrate concentrations in drinking water in a sample of Spanish cities. We used ion chromatography to analyze the nitrate concentrations of public drinking water in 108 Spanish municipalities with more than 50,000 inhabitants (supplying 21,290,707 potential individuals). The samples were collected between January and April 2012. The total number of samples tested was 324. The median nitrate concentration was 3.47 mg/L (range: 0.38-66.76; interquartile range: 4.51). The water from 94% of the municipalities contained less than 15 mg/L. The concentration was higher than 25mg/L in only 3 municipalities and was greater than 50mg/L in one. Nitrate levels in most public drinking water supplies in municipalities inhabited by almost half of the Spanish population are below 15 mg/L. Copyright © 2014 SESPAS. Published by Elsevier Espana. All rights reserved.

  3. The Global Land-Ocean Temperature Index in Relation to Sunspot Number, the Atlantic Multidecadal Oscillation Index, the Mauna Loa Atmospheric Concentration of CO2, and Anthropogenic Carbon Emissions

    NASA Technical Reports Server (NTRS)

    Wilson, Robert M.

    2013-01-01

    Global warming/climate change has been a subject of scientific interest since the early 19th century. In particular, increases in the atmospheric concentration of carbon dioxide (CO2) have long been thought to account for Earth's increased warming, although the lack of a dependable set of observational data was apparent as late as the mid 1950s. However, beginning in the late 1950s, being associated with the International Geophysical Year, the opportunity arose to begin accurate continuous monitoring of the Earth's atmospheric concentration of CO2. Consequently, it is now well established that the atmospheric concentration of CO2, while varying seasonally within any particular year, has steadily increased over time. Associated with this rising trend in the atmospheric concentration of CO2 is a rising trend in the surface-air and sea-surface temperatures (SSTs). This Technical Publication (TP) examines the statistical relationships between 10-year moving averages (10-yma) of the Global Land-Ocean Temperature Index (GLOTI), sunspot number (SSN), the Atlantic Multidecadal Oscillation (AMO) index, and the Mauna Loa CO2 (MLCO2) index for the common interval 1964-2006, where the 10-yma values are used to indicate trends in the data. Scatter plots using the 10-yma values between GLOTI and each of the other parameters are determined, both as single-variate and multivariate fits. Scatter plots are also determined for MLCO2 using single-variate and bivariate (BV) fits, based on the GLOTI alone and the GLOTI in combination with the AMO index. On the basis of the inferred preferential fits for MLCO2, estimates for MLCO2 are determined for the interval 1885-1964, thereby yielding an estimate of the preindustrial level of atmospheric concentration of CO2. Lastly, 10-yma values of MLCO2 are compared against 10-yma estimates of the total carbon emissions (TCE) to determine the likelihood that manmade sources of carbon emissions are indeed responsible for the recent warming now

  4. Experimental characterization of Fresnel-Köhler concentrators

    NASA Astrophysics Data System (ADS)

    Zamora, Pablo; Benítez, Pablo; Mohedano, Rubén; Cvetković, Aleksandra; Vilaplana, Juan; Li, Yang; Hernández, Maikel; Chaves, Julio; Miñano, Juan C.

    2012-01-01

    Most cost-effective concentrated photovoltaics (CPV) systems are based on an optical train comprising two stages, the first being a Fresnel lens. Among them, the Fresnel-Köhler (FK) concentrator stands out owing to both performance and practical reasons. We describe the experimental measurements procedure for FK concentrator modules. This procedure includes three main types of measurements: electrical efficiency, acceptance angle, and irradiance uniformity at the solar cell plane. We have collected here the performance features of two different FK prototypes (ranging different f-numbers, concentration ratios, and cell sizes). The electrical efficiencies measured in both prototypes are high and fit well with the models, achieving values up to 32.7% (temperature corrected, and with no antireflective coating on SOE or POE surfaces) in the best case. The measured angular transmission curves show large acceptance angles, again perfectly matching the expected values [measured concentration acceptance product (CAP) values over 0.56]. The irradiance pattern on the cell (obtained with a digital camera) shows an almost perfectly uniform distribution, as predicted by raytrace simulations. All these excellent on-sun results confirm the FK concentrator as a potentially cost-effective solution for the CPV market.

  5. Emissions of particulate-bound elements from biodiesel and ultra low sulfur diesel: size distribution and risk assessment.

    PubMed

    Betha, Raghu; Balasubramanian, Rajasekhar

    2013-01-01

    Use of waste cooking oil derived biodiesel (WCOB) as an alternative fuel in diesel engines has increased significantly in recent years. The impact of WCOB on particulate emissions from diesel engines needs to be investigated thoroughly. This study was conducted to make a comparative evaluation and size-differentiated speciation of the particulate bound elements from ultra low sulfur diesel (ULSD) and WCOB and a blend of both of the fuels (B50). Particle mass and their elemental size distributions ranging from 0.01-5.6 μm were measured. It was observed that more ultrafine particles (UFPs, <100 nm) were emitted when the engine was fueled with WCOB. Fifteen particulate-bound elements such as K, Al, Mg, Co, Cr, Cu, Fe, Mn, Cd, Ni, As, Ba, Pb, Zn and Sr were investigated and reported in this study. Potential health risk associated with these particulate bound elements upon inhalation was also evaluated based on dose-response assessments for both adults and children. The findings indicate that the exposure to PM of the B100 exhaust is relatively more hazardous and may pose adverse health effects compared to that of ULSD. Also, investigations on human health risk due to exposure to UFPs indicate that UFPs contribute a major fraction (>70%) of the total estimated health risk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Number Sense on the Number Line

    ERIC Educational Resources Information Center

    Woods, Dawn Marie; Ketterlin Geller, Leanne; Basaraba, Deni

    2018-01-01

    A strong foundation in early number concepts is critical for students' future success in mathematics. Research suggests that visual representations, like a number line, support students' development of number sense by helping them create a mental representation of the order and magnitude of numbers. In addition, explicitly sequencing instruction…

  7. How Well Does Dual-Energy Computed Tomography With Metal Artifact Reduction Software Improve Image Quality and Quantify Computed Tomography Number and Iodine Concentration?

    PubMed

    Ohira, Shingo; Kanayama, Naoyuki; Wada, Kentaro; Karino, Tsukasa; Nitta, Yuya; Ueda, Yoshihiro; Miyazaki, Masayoshi; Koizumi, Masahiko; Teshima, Teruki

    2018-04-02

    The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS). Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV). The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively. Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.

  8. Quantifying Main Trends in Lysozyme Nucleation: The Effects of Precipitant Concentration, Supersaturation and Impurities

    NASA Technical Reports Server (NTRS)

    Burke, Michael W.; Leardi, Riccardo; Judge, Russell A.; Pusey, Marc L.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    Full factorial experimental design incorporating multi-linear regression analysis of the experimental data allows quick identification of main trends and effects using a limited number of experiments. In this study these techniques were employed to identify the effect of precipitant concentration, supersaturation, and the presence of an impurity, the physiological lysozyme dimer, on the nucleation rate and crystal dimensions of the tetragonal forin of chicken egg white lysozyme. Decreasing precipitant concentration, increasing supers aturation, and increasing impurity, were found to increase crystal numbers. The crystal axial ratio decreased with increasing precipitant concentration, independent of impurity.

  9. Ultrafine particle measurement and related EPA research studies

    EPA Science Inventory

    Webinar slides to present information on measuring ultrafine particles at the request of the 2013 MARAMA Monitoring Committee. The talk covers near-road monitoring, instrument intercomparison, and general overview of UFP monitoring technology.

  10. Concentrated affluence, concentrated disadvantage, and children's readiness for school: a population-based, multi-level investigation.

    PubMed

    Carpiano, Richard M; Lloyd, Jennifer E V; Hertzman, Clyde

    2009-08-01

    A number of studies demonstrates a relationship between neighbourhood concentration of affluence and disadvantage and the health and development of its residents. We contribute to this literature by testing hypotheses about the relationship between neighbourhood-level concentrated affluence/disadvantage and child-level developmental outcomes in a study population of 37,798 Kindergarten children residing in 433 neighbourhoods throughout the province of British Columbia, Canada. We utilise a previously-validated measure of neighbourhood socioeconomic composition--the Index of Concentration at the Extremes (ICE)--which not only allows for more precise estimation of the competing influences of concentrated affluence and disadvantage, but also facilitates examination of the potential impact of neighbourhood-level income inequality. Our findings show that increases in neighbourhood affluence are associated with increases in children's scores on the Early Development Instrument (EDI), a holistic measure of Kindergarteners' readiness for school. Particularly noteworthy is that, for four of the five EDI scales (physical, social, emotional, and communication) and the total score, results indicate a significant curvilinear relationship--whereby the highest average child-level outcomes are not found in locations with the highest concentrations of affluence, but rather in locations with relatively equal proportions of affluent and disadvantaged families. This finding suggests, first, that concentrated affluence may have diminishing rates of return on contributing to enhanced child development, and, second, that children residing in mixed-income neighbourhoods may benefit both from the presence of affluent residents and from the presence of services and institutions aimed at assisting lower-income residents. Implications and future directions are discussed.

  11. Viscosity of a concentrated suspension of rigid monosized particles

    NASA Astrophysics Data System (ADS)

    Brouwers, H. J. H.

    2010-05-01

    This paper addresses the relative viscosity of concentrated suspensions loaded with unimodal hard particles. So far, exact equations have only been put forward in the dilute limit, e.g., by Einstein [A. Einstein, Ann. Phys. 19, 289 (1906) (in German); Ann. Phys. 34, 591 (1911) (in German)] for spheres. For larger concentrations, a number of phenomenological models for the relative viscosity was presented, which depend on particle concentration only. Here, an original and exact closed form expression is derived based on geometrical considerations that predicts the viscosity of a concentrated suspension of monosized particles. This master curve for the suspension viscosity is governed by the relative viscosity-concentration gradient in the dilute limit (for spheres the Einstein limit) and by random close packing of the unimodal particles in the concentrated limit. The analytical expression of the relative viscosity is thoroughly compared with experiments and simulations reported in the literature, concerning both dilute and concentrated suspensions of spheres, and good agreement is found.

  12. Entrainment at a sediment concentration interface in turbulent channel flow

    NASA Astrophysics Data System (ADS)

    Salinas, Jorge; Shringarpure, Mrugesh; Cantero, Mariano; Balachandar, S.

    2016-11-01

    In this work we address the role of turbulence on entrainment at a sediment concentration interface. This process can be conceived as the entrainment of sediment-free fluid into the bottom sediment-laden flow, or alternatively, as the entrainment of sediment into the top sediment-free flow. We have performed direct numerical simulations for fixed Reynolds and Schmidt numbers while varying the values of Richardson number and particle settling velocity. The analysis performed shows that the ability of the flow to pick up a given sediment size decreases with the distance from the bottom, and thus only fine enough sediment particles are entrained across the sediment concentration interface. For these cases, the concentration profiles evolve to a final steady state in good agreement with the well-known Rouse profile. The approach towards the Rouse profile happens through a transient self-similar state. Detailed analysis of the three dimensional structure of the sediment concentration interface shows the mechanisms by which sediment particles are lifted up by tongues of sediment-laden fluid with positive correlation between vertical velocity and sediment concentration. Finally, the mixing ability of the flow is addressed by monitoring the center of mass of the sediment-laden layer. With the support of ExxonMobil, NSF, ANPCyT, CONICET.

  13. Traffic pollutants measured inside vehicles waiting in line at a major US-Mexico Port of Entry.

    PubMed

    Quintana, Penelope J E; Khalighi, Mehdi; Castillo Quiñones, Javier Emmanuel; Patel, Zalak; Guerrero Garcia, Jesus; Martinez Vergara, Paulina; Bryden, Megan; Mantz, Antoinette

    2018-05-01

    At US-Mexico border Ports of Entry, vehicles idle for long times waiting to cross northbound into the US. Long wait times at the border have mainly been studied as an economic issue, however, exposures to emissions from idling vehicles can also present an exposure risk. Here we present the first data on in-vehicle exposures to driver and passengers crossing the US-Mexico border at the San Ysidro, California Port of Entry (SYPOE). Participants were recruited who regularly commuted across the border in either direction and told to drive a scripted route between two border universities, one in the US and one in Mexico. Instruments were placed in participants' cars prior to commute to monitor-1-minute average levels of the traffic pollutants ultrafine particles (UFP), black carbon (BC) and carbon monoxide (CO) in the breathing zone of drivers and passengers. Location was determined by a GPS monitor. Results reported here are for 68 northbound participant trips. The highest median levels of in-vehicle UFP were recorded during the wait to cross at the SYPOE (median 29,692particles/cm 3 ) significantly higher than the portion of the commute in the US (median 20,508particles/cm 3 ) though not that portion in Mexico (median 22, 191particles/cm 3 ). In-vehicle BC levels at the border were significantly lower than in other parts of the commute. Our results indicate that waiting in line at the SYPOE contributes a median 62.5% (range 15.5%-86.0%) of a cross-border commuter's exposure to UFP and a median 44.5% (range (10.6-79.7%) of exposure to BC inside the vehicle while traveling in the northbound direction. Reducing border wait time can significantly reduce in-vehicle exposures to toxic air pollutants such as UFP and BC, and these preventable exposures can be considered an environmental justice issue. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Coarse and fine particles but not ultrafine particles in urban air trigger hospital admission for asthma in children.

    PubMed

    Iskandar, Amne; Andersen, Zorana Jovanovic; Bønnelykke, Klaus; Ellermann, Thomas; Andersen, Klaus Kaae; Bisgaard, Hans

    2012-03-01

    Short-term exposure to air pollution can trigger hospital admissions for asthma in children, but it is not known which components of air pollution are most important. There are no available studies on the particular effect of ultrafine particles (UFPs) on paediatric admissions for asthma. To study whether short-term exposure to air pollution is associated with hospital admissions for asthma in children. It is hypothesised that (1) the association between asthma admissions and air pollution is stronger with UFPs than with coarse (PM10) and fine (PM2.5) particles, nitrogen oxides (NOx) or nitrogen dioxide (NO2); and (2) infants are more susceptible to the effects of exposure to air pollution than older children. Daily counts of admissions for asthma in children aged 0-18 years to hospitals located within a 15 km radius of the central fixed background urban air pollution measurement station in Copenhagen between 2001 and 2008 were extracted from the Danish National Patient Registry. A time-stratified case crossover design was applied and data were analysed using conditional logistic regression to estimate the effect of air pollution on asthma admissions. A significant association was found between hospital admissions for asthma in children aged 0-18 years and NOx (OR 1.11; 95% CI 1.05 to 1.17), NO2 (1.10; 95% CI 1.04 to 1.16), PM10 (1.07; 95% CI 1.03 to 1.12) and PM2.5 (1.09; 95% CI 1.04 to 1.13); there was no association with UFPs. The association was stronger in infants than in older children for all pollutants, but no statistically significant interaction was detected. Short-term exposure to air pollution can trigger hospital admission for asthma in children, with infants possibly being most susceptible. These effects seemed to be mediated by larger particles and traffic-related gases, whereas UFPs showed no effect.

  15. Spatial and temporal variation of sources contributing to quasi-ultrafine particulate matter PM0.36 in Augsburg, Germany.

    PubMed

    Li, Fengxia; Schnelle-Kreis, Jürgen; Cyrys, Josef; Wolf, Kathrin; Karg, Erwin; Gu, Jianwei; Orasche, Jürgen; Abbaszade, Gülcin; Peters, Annette; Zimmermann, Ralf

    2018-08-01

    to study the sources contributing to quasi-ultrafine particle (UFP) organic carbon and the spatial temporal variability of the sources. 24h quasi-UFP (particulate matter <0.36μm in this study) was sampled at a reference site continuously and at one of 5 other sites (T1, T2, T3, T4 and B1) in parallel in Augsburg, Germany from April 11th, 2014 to February 22nd, 2015, attempting to conduct 2-week campaigns at each site in 3 different seasons. Positive matrix factorization (PMF) was applied to measured organic tracers for source apportionment analyses. Pearson correlation coefficient r and coefficient of divergence (COD) were calculated to investigate spatial temporal variation of source contributions. 5 sources were identified comprising biomass burning (BB), traffic emissions (Traffic), biogenic secondary organic aerosol (bioSOA), isoprene originated secondary organic aerosol (isoSOA) and biomass burning related secondary organic aerosol (bbSOA). In general, good temporal correlation and uniform distribution within the study area are found for bioSOA and bbSOA, probably resulting from regional formation/transport. Lower temporal correlation and spatial heterogeneity of isoSOA were found at the city background site with local influence from green space and less traffic impact. BB demonstrated very good temporal correlation, but higher contributions at sites influenced by local residential heating emissions were observed. Traffic showed the least seasonality and lower correlation over time among the sources. However, it demonstrated low spatial heterogeneity of absolute contribution, and only a few days of elevated contribution was found at T3 when wind came directly from the street nearby. temporal correlation and spatial variability of sources contributing to the organic fraction of quasi-UFP vary among sites and source types and show source-specific characteristics. Therefore, caution should be taken when using one monitor site measurement to assess human exposure

  16. Atmospheric particulate matter size distribution and concentration in West Virginia coal mining and non-mining areas.

    PubMed

    Kurth, Laura M; McCawley, Michael; Hendryx, Michael; Lusk, Stephanie

    2014-07-01

    People who live in Appalachian areas where coal mining is prominent have increased health problems compared with people in non-mining areas of Appalachia. Coal mines and related mining activities result in the production of atmospheric particulate matter (PM) that is associated with human health effects. There is a gap in research regarding particle size concentration and distribution to determine respiratory dose around coal mining and non-mining areas. Mass- and number-based size distributions were determined with an Aerodynamic Particle Size and Scanning Mobility Particle Sizer to calculate lung deposition around mining and non-mining areas of West Virginia. Particle number concentrations and deposited lung dose were significantly greater around mining areas compared with non-mining areas, demonstrating elevated risks to humans. The greater dose was correlated with elevated disease rates in the West Virginia mining areas. Number concentrations in the mining areas were comparable to a previously documented urban area where number concentration was associated with respiratory and cardiovascular disease.

  17. Correlation Of Giant Nuclei With Cloud Droplet Concentration

    NASA Astrophysics Data System (ADS)

    Jha, V.; Hudson, J. G.; Noble, S.

    2011-12-01

    The effect of giant nuclei (GN; larger than 1 micrometer particles produced by wind on the ocean surface) on warm rain has been debated for decades. During RICO (Rain in Cumulus over the Ocean) Hudson et al. (2011) found a negative correlation (R) between CCN concentrations at 1% supersaturation (S) and large cloud droplet concentrations (Fig. 1A). This reversal from positive R for CCN with total (or small) cloud droplet concentrations (left side of Fig. 1A) was explained by the greater competition for condensate, which thus limits droplet sizes when CCN concentrations are higher. The negative R increased in magnitude with altitude, and the droplet size where the maximum negative R occurred increased with altitude (Fig. 1A). However, at all altitudes this negative R decreased in magnitude for even larger cloud and drizzle drops (right side of Fig. 1A except highest altitude). The decrease in magnitude of the negative R was greater for increasing drop sizes at higher altitudes. Thus, at the higher altitudes, R for CCN with large drizzle drops was of low negative magnitude and even positive at the highest RICO altitudes. The disparity between CCN and drizzle drop concentrations precluded a causal relationship. But the high R between GN and drizzle drop concentrations at the highest altitudes (Fig. 1B) and the comparable concentrations indicated that GN were engendering drizzle. This is supported by the increasing R with altitude of the GN-drizzle drop R (right side of Fig. 1B). The conclusion of a GN-drizzle connection is also supported by the fact that CCN concentrations should inhibit drizzle. This analysis of Hudson et al. (2011) is here expanded to include correlations of CCN concentrations at lower S with cloud and drizzle drop concentrations to investigate intermediate relationships; i.e., between large nuclei (i.e., 0.1-1 micrometer; critical S 0.1-0.01%) and drizzle drop concentrations. A shortcoming of Hudson et al. (2011) was the small number of high

  18. Threshold concentration in the nonlinear absorbance law.

    PubMed

    Tolbin, Alexander Yu; Pushkarev, Victor E; Tomilova, Larisa G; Zefirov, Nikolay S

    2017-05-24

    A new nonlinear relationship of the absorption coefficient with the concentration was proposed, allowing the calculation of the threshold concentration, which shows that there is a deviation from the Beer-Lambert law. The nonlinear model was successfully tested on a stable dimeric phthalocyanine ligand of J-type in solvents with different polarity. It was shown that deviation from the linearity is connected with a specific association of the macrocyclic molecules, which, in the case of non-polar solvents, leads to the formation of H-aggregates composed of J-type dimeric molecules. The aggregation number was estimated to be less than 1.5, which has allowed us to conduct a series of analytical experiments in a wide range of concentrations (1 × 10 -6 -5 × 10 -4 mol L -1 ).

  19. Suppression of lymphocyte proliferation by marijuana components is related to cell number and cell source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, T.; Pross, S.; Newton, C.

    Conflicting reports have appeared concerning the effect of marijuana components on immune responsiveness. The authors have observed that the effect of cannabinoids on lymphocyte proliferation varied with both the concentration of the drug and the mitogen used. They now report that at a constant concentration of drug, the cannabinoid effect varied from no effect to suppression depending upon the number of cells in culture and the organ source of the cells. Dispersed cell suspensions of mouse lymph node, spleen, and thymus were prepared and cultured at varying cell numbers with either delta-9-tetrahydrocannabinol or 11-hydroxy-delta-9-tetrahydrocannabinol and various mitogens. Lymphocyte proliferation wasmore » analyzed by /sup 3/H-thymidine incorporation. T-lymphocyte mitogen responses in cultures containing high cell numbers were unaffected by the cannabinoids but as cell numbers were reduced a suppression of the response was observed. Furthermore, thymus cells were considerably more susceptible to cannabinoid suppression than cells from either lymph node or spleen. These results suggest that certain lymphocyte subpopulations are more sensitive to cannabinoid suppression and that in addition to drug concentration other variables such as cell number and cell source must be considered when analyzing cannabinoid effects.« less

  20. Quantifying Main Trends in Lysozyme Nucleation: The Effect of Precipitant Concentration and Impurities

    NASA Technical Reports Server (NTRS)

    Burke, Michael W.; Judge, Russell A.; Pusey, Marc L.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    Full factorial experiment design incorporating multi-linear regression analysis of the experimental data allows the main trends and effects to be quickly identified while using only a limited number of experiments. These techniques were used to identify the effect of precipitant concentration and the presence of an impurity, the physiological lysozyme dimer, on the nucleation rate and crystal dimensions of the tetragonal form of chicken egg white lysozyme. Increasing precipitant concentration was found to decrease crystal numbers, the magnitude of this effect also depending on the supersaturation. The presence of the dimer generally increased nucleation. The crystal axial ratio decreased with increasing precipitant concentration independent of impurity.

  1. An Algorithm for the Retrieval of Droplet Number Concentration and Geometrical Thickness of Stratiform Marine Boundary Layer Clouds Applied to MODIS Radiometric Observations.

    NASA Astrophysics Data System (ADS)

    Schüller, Lothar; Bennartz, Ralf; Fischer, Jürgen; Brenguier, Jean-Louis

    2005-01-01

    Algorithms are now currently used for the retrieval of cloud optical thickness and droplet effective radius from multispectral radiance measurements. This paper extends their application to the retrieval of cloud droplet number concentration, cloud geometrical thickness, and liquid water path in shallow convective clouds, using an algorithm that was previously tested with airborne measurements of cloud radiances and validated against in situ measurements of the same clouds. The retrieval is based on a stratified cloud model of liquid water content and droplet spectrum. Radiance measurements in visible and near-infrared channels of the Moderate Resolution Imaging Spectroradiometer (MODIS), which is operated from the NASA platforms Terra and Aqua, are analyzed. Because of uncertainties in the simulation of the continental surface reflectance, the algorithm is presently limited to the monitoring of the microphysical structure of boundary layer clouds over the ocean. Two MODIS scenes of extended cloud fields over the North Atlantic Ocean trade wind region are processed. A transport and dispersion model (the Hybrid Single-Particle Lagrangian Integrated Trajectory Model, HYSPLIT4) is also used to characterize the origin of the air masses and hence their aerosol regimes. One cloud field formed in an air mass that was advected from southern Europe and North Africa. It shows high values of the droplet concentration when compared with the second cloud system, which developed in a more pristine environment. The more pristine case also exhibits a higher geometrical thickness and, thus, liquid water path, which counterbalances the expected cloud albedo increase of the polluted case. Estimates of cloud liquid water path are then compared with retrievals from the Special Sensor Microwave Imager (SSM/I). SSM/I-derived liquid water paths are in good agreement with the MODIS-derived values.

  2. A view on thermodynamics of concentrated electrolytes: Modification necessity for electrostatic contribution of osmotic coefficient

    NASA Astrophysics Data System (ADS)

    Sahu, Jyoti; Juvekar, Vinay A.

    2018-05-01

    Prediction of the osmotic coefficient of concentrated electrolytes is needed in a wide variety of industrial applications. There is a need to correctly segregate the electrostatic contribution to osmotic coefficient from nonelectrostatic contribution. This is achieved in a rational way in this work. Using the Robinson-Stokes-Glueckauf hydrated ion model to predict non-electrostatic contribution to the osmotic coefficient, it is shown that hydration number should be independent of concentration so that the observed linear dependence of osmotic coefficient on electrolyte concentration in high concentration range could be predicted. The hydration number of several electrolytes (LiCl, NaCl, KCl, MgCl2, and MgSO4) has been estimated by this method. The hydration number predicted by this model shows correct dependence on temperature. It is also shown that the electrostatic contribution to osmotic coefficient is underpredicted by the Debye-Hückel theory at concentration beyond 0.1 m. The Debye-Hückel theory is modified by introducing a concentration dependent hydrated ionic size. Using the present analysis, it is possible to correctly estimate the electrostatic contribution to the osmotic coefficient, beyond the range of validation of the D-H theory. This would allow development of a more fundamental model for electrostatic interaction at high electrolyte concentrations.

  3. Effect of mercury chloride to number of melano-macrophage centers on the kidney of carp fish (Cyprinus carpio)

    NASA Astrophysics Data System (ADS)

    Mubarokah, L.; Tjahjaningsih, W.; Sulmartiwi, L.

    2018-04-01

    Mercury chloride can cause immunotoxic effects on fish. The accumulation or aggregate of melano-macrophages centers (MMCs) in the kidney is a feature of cellular immune response, so it can be used as a bioindicator of heavy metal toxicity in waters. This research aims to determine an effect of heavy metal exposure concentration of mercury chloride (HgCl2) on a number of MMCs from common carp kidney. This research using four treatments of mercury chloride: 0 ppm, 0.01 ppm, 0.05 ppm and 0.1 ppm. The main parameters were the number of MMCs in kidney common carp. Supporting parameter was behavior change, water quality and concentration of mercury in the water and kidney. The results of the research showed that the concentration the heavy metal exposure concentration of mercury chloride (HgCl2) affected the number of MMCs from common carp (Cyprinus carpio) kidney. The number of MMCs in the kidney of common carp exposed to mercury chloride 0.01 ppm, 0.05 ppm and 0.1 ppm increased compared to carp was not exposed to mercury chloride (0 ppm).

  4. Emission of particulate matter from a desktop three-dimensional (3D) printer

    PubMed Central

    Yi, Jinghai; LeBouf, Ryan F.; Duling, Matthew G.; Nurkiewicz, Timothy; Chen, Bean T.; Schwegler-Berry, Diane; Virji, M. Abbas; Stefaniak, Aleksandr B.

    2016-01-01

    ABSTRACT Desktop three-dimensional (3D) printers are becoming commonplace in business offices, public libraries, university labs and classrooms, and even private homes; however, these settings are generally not designed for exposure control. Prior experience with a variety of office equipment devices such as laser printers that emit ultrafine particles (UFP) suggests the need to characterize 3D printer emissions to enable reliable risk assessment. The aim of this study was to examine factors that influence particulate emissions from 3D printers and characterize their physical properties to inform risk assessment. Emissions were evaluated in a 0.5-m3 chamber and in a small room (32.7 m3) using real-time instrumentation to measure particle number, size distribution, mass, and surface area. Factors evaluated included filament composition and color, as well as the manufacturer-provided printer emissions control technologies while printing an object. Filament type significantly influenced emissions, with acrylonitrile butadiene styrene (ABS) emitting larger particles than polylactic acid (PLA), which may have been the result of agglomeration. Geometric mean particle sizes and total particle (TP) number and mass emissions differed significantly among colors of a given filament type. Use of a cover on the printer reduced TP emissions by a factor of 2. Lung deposition calculations indicated a threefold higher PLA particle deposition in alveoli compared to ABS. Desktop 3D printers emit high levels of UFP, which are released into indoor environments where adequate ventilation may not be present to control emissions. Emissions in nonindustrial settings need to be reduced through the use of a hierarchy of controls, beginning with device design, followed by engineering controls (ventilation) and administrative controls such as choice of filament composition and color. PMID:27196745

  5. Transition to organized behavior on suspensions of concentrated bacteria

    NASA Astrophysics Data System (ADS)

    Ganguly, Sujoy; Cisneros, Luis; Kessler, John; Goldstein, Raymond

    2008-11-01

    Concentrated populations of the swimming bacterium Bacillus subtilis develop a collective phase, the Zooming BioNematic, that exhibits large-scale coherence analogous to the molecular alignment of nematic liquid crystals. Bacterial suspensions were prepared in order to experimentally measure the transition to organized behavior as a function of the cell number concentration. PIV analysis was used to obtain cell velocities and define an order parameter in order to characterize the dynamics of the system.

  6. 27 CFR 18.56 - Receipt of concentrate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ....56 Section 18.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.56 Receipt... Office of Management and Budget under control number 1512-0098) [T.D. ATF-455, 66 FR 29482, May 31, 2001] ...

  7. 27 CFR 18.56 - Receipt of concentrate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....56 Section 18.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS PRODUCTION OF VOLATILE FRUIT-FLAVOR CONCENTRATE Operations § 18.56 Receipt... Office of Management and Budget under control number 1512-0098) [T.D. ATF-455, 66 FR 29482, May 31, 2001] ...

  8. Wide-range particle characterization and elemental concentration in Beijing aerosol during the 2013 Spring Festival.

    PubMed

    Jing, Hui; Li, Yu-Feng; Zhao, Jiating; Li, Bai; Sun, Jialong; Chen, Rui; Gao, Yuxi; Chen, Chunying

    2014-09-01

    The number and mass concentration, size distribution, and the concentration of 16 elements were studied in aerosol samples during the Spring Festival celebrations in 2013 in Beijing, China. Both the number and mass concentration increased sharply in a wide range from 10 nm to 10 μm during the firecrackers and fireworks activities. The prominent increase of the number concentration was in 50 nm-500 nm with a peak of 1.7 × 10(5)/cm(3) at 150 nm, which is 8 times higher than that after 1.5 h. The highest mass concentration was in 320-560 nm, which is 4 times higher than the control. K, Mg, Sr, Ba and Pb increased sharply during the firework activities in PM10. Although the aerosol emission from firework activities is a short-term air quality degradation event, there may be a substantial hazard arising from the chemical composition of the emitted particles. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Oxygen Concentration Inside a Functioning Photosynthetic Cell

    PubMed Central

    Kihara, Shigeharu; Hartzler, Daniel A.; Savikhin, Sergei

    2014-01-01

    The excess oxygen concentration in the photosynthetic membranes of functioning oxygenic photosynthetic cells was estimated using classical diffusion theory combined with experimental data on oxygen production rates of cyanobacterial cells. The excess oxygen concentration within the plesiomorphic cyanobacterium Gloeobactor violaceus is only 0.025 μM, or four orders of magnitude lower than the oxygen concentration in air-saturated water. Such a low concentration suggests that the first oxygenic photosynthetic bacteria in solitary form could have evolved ∼2.8 billion years ago without special mechanisms to protect them against reactive oxygen species. These mechanisms instead could have been developed during the following ∼500 million years while the oxygen level in the Earth’s atmosphere was slowly rising. Excess oxygen concentrations within individual cells of the apomorphic cyanobacteria Synechocystis and Synechococcus are 0.064 and 0.25 μM, respectively. These numbers suggest that intramembrane and intracellular proteins in isolated oxygenic photosynthetic cells are not subjected to excessively high oxygen levels. The situation is different for closely packed colonies of photosynthetic cells. Calculations show that the excess concentration within colonies that are ∼40 μm or larger in diameter can be comparable to the oxygen concentration in air-saturated water, suggesting that species forming colonies require protection against reactive oxygen species even in the absence of oxygen in the surrounding atmosphere. PMID:24806920

  10. Two-way effect modifications of air pollution and air temperature on total natural and cardiovascular mortality in eight European urban areas.

    PubMed

    Chen, Kai; Wolf, Kathrin; Breitner, Susanne; Gasparrini, Antonio; Stafoggia, Massimo; Samoli, Evangelia; Andersen, Zorana Jovanovic; Bero-Bedada, Getahun; Bellander, Tom; Hennig, Frauke; Jacquemin, Bénédicte; Pekkanen, Juha; Hampel, Regina; Cyrys, Josef; Peters, Annette; Schneider, Alexandra

    2018-07-01

    Although epidemiological studies have reported associations between mortality and both ambient air pollution and air temperature, it remains uncertain whether the mortality effects of air pollution are modified by temperature and vice versa. Moreover, little is known on the interactions between ultrafine particles (diameter ≤ 100 nm, UFP) and temperature. We investigated whether the short-term associations of particle number concentration (PNC in the ultrafine range (≤100 nm) or total PNC ≤ 3000 nm, as a proxy for UFP), particulate matter ≤ 2.5 μm (PM 2.5 ) and ≤ 10 μm (PM 10 ), and ozone with daily total natural and cardiovascular mortality were modified by air temperature and whether air pollution levels affected the temperature-mortality associations in eight European urban areas during 1999-2013. We first analyzed air temperature-stratified associations between air pollution and total natural (nonaccidental) and cardiovascular mortality as well as air pollution-stratified temperature-mortality associations using city-specific over-dispersed Poisson additive models with a distributed lag nonlinear temperature term in each city. All models were adjusted for long-term and seasonal trend, day of the week, influenza epidemics, and population dynamics due to summer vacation and holidays. City-specific effect estimates were then pooled using random-effects meta-analysis. Pooled associations between air pollutants and total and cardiovascular mortality were overall positive and generally stronger at high relatively compared to low air temperatures. For example, on days with high air temperatures (>75th percentile), an increase of 10,000 particles/cm 3 in PNC corresponded to a 2.51% (95% CI: 0.39%, 4.67%) increase in cardiovascular mortality, which was significantly higher than that on days with low air temperatures (<25th percentile) [-0.18% (95% CI: -0.97%, 0.62%)]. On days with high air pollution (>50th percentile), both heat

  11. A concentrated electrolyte for zinc hexacyanoferrate electrodes in aqueous rechargeable zinc-ion batteries

    NASA Astrophysics Data System (ADS)

    Kim, D.; Lee, C.; Jeong, S.

    2018-01-01

    In this study, a concentrated electrolyte was applied in an aqueous rechargeable zinc-ion battery system with a zinc hexacyanoferrate (ZnHCF) electrode to improve the electrochemical performance by changing the hydration number of the zinc ions. To optimize the active material, ZnHCF was synthesized using aqueous solutions of zinc nitrate with three different concentrations. The synthesized materials exhibited some differences in structure, crystallinity, and particle size, as observed by X-ray diffraction and scanning electron microscopy. Subsequently, these well-structured materials were applied in electrochemical tests. A more than two-fold improvement in the charge/discharge capacities was observed when the concentrated electrolyte was used instead of the dilute electrolyte. Additionally, the cycling performance observed in the concentrated electrolyte was superior to that in the dilute electrolyte. This improvement in the electrochemical performance may result from a decrease in the hydration number of the zinc ions in the concentrated electrolyte.

  12. Vascular effects of ultrafine particles in persons with type 2 diabetes

    EPA Science Inventory

    BACKGROUND: Diabetes confers an increased risk for cardiovascular effects of airborne particles. OBJECTIVE: We hypothesized that inhalation of elemental carbon ultrafine particles (UFP) would activate blood platelets and vascular endothelium in people with type 2 diabetes. ...

  13. The Mental Number Line in Dyscalculia: Impaired Number Sense or Access From Symbolic Numbers?

    PubMed

    Lafay, Anne; St-Pierre, Marie-Catherine; Macoir, Joël

    Numbers may be manipulated and represented mentally over a compressible number line oriented from left to right. According to numerous studies, one of the primary reasons for dyscalculia is related to improper understanding of the mental number line. Children with dyscalculia usually show difficulty when they have to place Arabic numbers on a physical number line. However, it remains unclear whether they have a deficit with the mental number line per se or a deficit with accessing it from nonsymbolic and/or symbolic numbers. Quebec French-speaking 8- to 9-year-old children with (24) and without (37) dyscalculia were assessed with transcoding tasks ( number-to-position and position-to-number) designed to assess the acuity of the mental number line with Arabic and spoken numbers as well as with analogic numerosities. Results showed that children with dyscalculia produced a larger percentage absolute error than children without mathematics difficulties in every task except the number-to-position transcoding task with analogic numerosities. Hence, these results suggested that children with dyscalculia do not have a general deficit of the mental number line but rather a deficit with accessing it from symbolic numbers.

  14. Estimating Marine Aerosol Particle Volume and Number from Maritime Aerosol Network Data

    NASA Technical Reports Server (NTRS)

    Sayer, A. M.; Smirnov, A.; Hsu, N. C.; Munchak, L. A.; Holben, B. N.

    2012-01-01

    As well as spectral aerosol optical depth (AOD), aerosol composition and concentration (number, volume, or mass) are of interest for a variety of applications. However, remote sensing of these quantities is more difficult than for AOD, as it is more sensitive to assumptions relating to aerosol composition. This study uses spectral AOD measured on Maritime Aerosol Network (MAN) cruises, with the additional constraint of a microphysical model for unpolluted maritime aerosol based on analysis of Aerosol Robotic Network (AERONET) inversions, to estimate these quantities over open ocean. When the MAN data are subset to those likely to be comprised of maritime aerosol, number and volume concentrations obtained are physically reasonable. Attempts to estimate surface concentration from columnar abundance, however, are shown to be limited by uncertainties in vertical distribution. Columnar AOD at 550 nm and aerosol number for unpolluted maritime cases are also compared with Moderate Resolution Imaging Spectroradiometer (MODIS) data, for both the present Collection 5.1 and forthcoming Collection 6. MODIS provides a best-fitting retrieval solution, as well as the average for several different solutions, with different aerosol microphysical models. The average solution MODIS dataset agrees more closely with MAN than the best solution dataset. Terra tends to retrieve lower aerosol number than MAN, and Aqua higher, linked with differences in the aerosol models commonly chosen. Collection 6 AOD is likely to agree more closely with MAN over open ocean than Collection 5.1. In situations where spectral AOD is measured accurately, and aerosol microphysical properties are reasonably well-constrained, estimates of aerosol number and volume using MAN or similar data would provide for a greater variety of potential comparisons with aerosol properties derived from satellite or chemistry transport model data.

  15. Wavelet investigation of preferential concentration in particle-laden turbulence

    NASA Astrophysics Data System (ADS)

    Bassenne, Maxime; Urzay, Javier; Schneider, Kai; Moin, Parviz

    2017-11-01

    Direct numerical simulations of particle-laden homogeneous-isotropic turbulence are employed in conjunction with wavelet multi-resolution analyses to study preferential concentration in both physical and spectral spaces. Spatially-localized energy spectra for velocity, vorticity and particle-number density are computed, along with their spatial fluctuations that enable the quantification of scale-dependent probability density functions, intermittency and inter-phase conditional statistics. The main result is that particles are found in regions of lower turbulence spectral energy than the corresponding mean. This suggests that modeling the subgrid-scale turbulence intermittency is required for capturing the small-scale statistics of preferential concentration in large-eddy simulations. Additionally, a method is defined that decomposes a particle number-density field into the sum of a coherent and an incoherent components. The coherent component representing the clusters can be sparsely described by at most 1.6% of the total number of wavelet coefficients. An application of the method, motivated by radiative-heat-transfer simulations, is illustrated in the form of a grid-adaptation algorithm that results in non-uniform meshes refined around particle clusters. It leads to a reduction of the number of control volumes by one to two orders of magnitude. PSAAP-II Center at Stanford (Grant DE-NA0002373).

  16. Optimal number of spacers in CRISPR arrays

    PubMed Central

    Severinov, Konstantin; Ispolatov, Iaroslav

    2017-01-01

    Prokaryotic organisms survive under constant pressure of viruses. CRISPR-Cas system provides its prokaryotic host with an adaptive immune defense against viruses that have been previously encountered. It consists of two components: Cas-proteins that cleave the foreign DNA and CRISPR array that suits as a virus recognition key. CRISPR array consists of a series of spacers, short pieces of DNA that originate from and match the corresponding parts of viral DNA called protospacers. Here we estimate the number of spacers in a CRISPR array of a prokaryotic cell which maximizes its protection against a viral attack. The optimality follows from a competition between two trends: too few distinct spacers make host vulnerable to an attack by a virus with mutated corresponding protospacers, while an excessive variety of spacers dilutes the number of the CRISPR complexes armed with the most recent and thus most useful spacers. We first evaluate the optimal number of spacers in a simple scenario of an infection by a single viral species and later consider a more general case of multiple viral species. We find that depending on such parameters as the concentration of CRISPR-Cas interference complexes and its preference to arm with more recently acquired spacers, the rate of viral mutation, and the number of viral species, the predicted optimal number of spacers lies within a range that agrees with experimentally-observed values. PMID:29253874

  17. Effects of preferential concentration on direct radiation transmission in a turbulent duct flow

    NASA Astrophysics Data System (ADS)

    Villafane, Laura; Banko, Andrew; Kim, Ji Hoon; Elkins, Chris; Eaton, John

    2017-11-01

    Inertial particles in turbulent flows preferentially concentrate, giving rise to spatial and temporal fluctuations of particle number density that affect radiation transmission through the medium. Positive particle correlations enhance direct transmission when compared to the exponential attenuation predicted by the Beer's Law for randomly distributed particles. In the context of a particle based solar receiver, this work studies the effects of preferential concentration and optical depth on direct transmission through a particle laden turbulent duct flow. Time resolved measurements of transmission through the mixture were performed for various particle loadings and Reynolds numbers, thus varying particle correlation lengths, optical depth and concentration fluctuations. These measurements were made using a photodiode to record the transmission of a collimated laser beam along the wall bisector of the duct. A synchronized high-speed camera provided particle positions along most of the beam path. Average and fluctuating radiation transmission results are compared to predictions derived from the imaged number density fields and to simplified analytical models. Simplified models are able to capture the correct trends with varying loading and preferential concentration. This work is funded by the Department of Energy's National Nuclear Security Administration, Grant #DE-NA0002373-1.

  18. Direct elicitation of template concentration from quantification cycle (Cq) distributions in digital PCR.

    PubMed

    Mojtahedi, Mitra; Fouquier d'Hérouël, Aymeric; Huang, Sui

    2014-01-01

    Digital PCR (dPCR) exploits limiting dilution of a template into an array of PCR reactions. From this array the number of reactions that contain at least one (as opposed to zero) initial template is determined, allowing inferring the original template concentration. Here we present a novel protocol to efficiently infer the concentration of a sample and its optimal dilution for dPCR from few targeted qPCR assays. By taking advantage of the real-time amplification feature of qPCR as opposed to relying on endpoint PCR assessment as in standard dPCR prior knowledge of template concentration is not necessary. This eliminates the need for serial dilutions in a separate titration and reduces the number of necessary reactions. We describe the theory underlying our approach and discuss experimental moments that contribute to uncertainty. We present data from a controlled experiment where the initial template concentration is known as proof of principle and apply our method on directly monitoring transcript level change during cell differentiation as well as gauging amplicon numbers in cDNA samples after pre-amplification. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  19. The Effects of Oxygen Concentration on Benthic Foraminiferal Growth and Size

    NASA Astrophysics Data System (ADS)

    Ng, B.; Keating-Bitonti, C.; Payne, J.

    2015-12-01

    Many organisms use oxygen through cellular respiration in order to gain energy. For this reason, oxygen has a significant influence on organism size and growth. The amount of oxygen an organism needs depends on its metabolic demand, which is partially a function organism size (i.e., mass). The Santa Monica Basin (SMB) is an oxygen minimum zone located off the southern coast of California that maintains a steep oxygen gradient and is thus an ideal location for conducting research on how oxygen influences organism size. Here we use benthic foraminifera, widespread single-celled protists that produce shells (tests), to study the controls of oxygen on organism size. Because cell mass and cell volume are correlated, we study trends in the log test volume of four abundant species from SMB: Uvigerina peregrina, Bolivina spissa, B. argentea, Loxostomum pseudobeyrichi. These foraminifera make multi-chambered tests, thus we also count the number of chambers per specimen in order to further assess their growth under varying oxygen concentrations. We analyzed the data using quantile regressions to determine trends in not only median values of the log test volume and number of chambers as a function of oxygen concentrations, but also in the 10th, 25th, 75th, and 90th percentiles because oxygen availability often constrains the maximum and minimum size of organisms. Our results show a positive correlation between oxygen concentration and the maximum log test volumes of L. pseudobeyrichi and B. argentea, supporting our hypothesis. However, we observed a negative correlation between oxygen concentration and the maximum percentiles of log test volume in U. peregrina. Nevertheless, U. peregrina still displays a positive correlation between chamber number and oxygen concentrations in line with our hypothesis. The preponderance of trends supporting a direct correlation between log test volume or chamber number and oxygen concentration suggest that oxygen limits the maximum obtainable

  20. Oscillations of a String with Concentrated Masses

    ERIC Educational Resources Information Center

    Gomez, B. J.; Repetto, C. E.; Stia, C. R.; Welti, R.

    2007-01-01

    In this work, the oscillations of a homogeneous string fixed at both ends, and loaded with a finite number of masses, are studied. Through a simple device, the cases with one and two concentrated masses are analysed in detail. The normal modes are observed and the corresponding frequencies are recorded. The experimental results and the solutions…