Sample records for uhcre tray located

  1. Source abundances of ultra heavy elements derived from UHCRE measurements.

    PubMed

    Domingo, C; Font, J; Baixeras, C; Fernandez, F

    1996-11-01

    A total of 205 tracks have been located, measured, and positively identified as originating from Ultra Heavy (Z > or = 65) cosmic ray ions with energies over 2 GeV/amu in the 10 UHCRE plastic track detector (mainly Lexan polycarbonate) stacks studied by our Group. About 40 values of reduced etch rate S have been obtained along each of these tracks. A method based on determining the gradient of S, together with calibration in accelerators, is used to determine the charge of each ion resulting in one of such tracks to obtain the charge spectrum of the recorded Ultra Heavy ions. The abundance ratio of ions with 87 < or = Z < or = 100 to those with 74 < or = Z < or = 86 as well as that of ions with 81 < or = Z < or = 86 to those with 74 < or = Z < or = 80 are calculated at 0.016 and 0.32, respectively, which agree with the values obtained from measurements in the HEAO-3 and Ariel-6 experiments. The abundance ratio of ions with 70 < or = Z < or = 73 to those with 74 < or = Z < or = 86 is also calculated, but its value (0.074) did not seem to be significant because of our detectors' low registration efficiency in the charge range 70 < or = Z < or = 73. A computer program developed by our Group, based on the Leaky Box cosmic ray propagation model, has been used to determine the source abundances of cosmic ray nuclei with Z > or = 65 inferred from the abundances measured in the UHCRE. It appeared that r-process synthesized elements were overabundant compared to the Solar System abundances, as predicted by other authors.

  2. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Wood, Bobby E.; Cromwell, Brian K.; Pender, Charles W.; Shepherd, Seth D.

    1992-01-01

    This paper describes infrared hemispherical reflectance measurements (2-15 microns) that were made on 58 chromic acid anodized tray clamps retrieved from the LDEF spacecraft. These clamps were used for maintaining the experiments in place and were located at various locations about the spacecraft. Changes in reflectance of the tray clamps at these locations were compared with atomic oxygen fluxes at the same locations. A decrease in absorption band depth was seen for the surfaces exposed to space indicating that there was some surface layer erosion. In all of the surfaces measured, little evidence of contamination was observed and none of the samples showed evidence of the brown nicotine stain that was so prominent in other experiments. Total emissivity values were calculated for both exposed and unexposed tray clamp surfaces. Only small differences, usually less than 1 percent, were observed. The spectral reflectances were measured using a hemi-ellipsoidal mirror reflectometer matched with an interferometer spectrometer. The rapid scanning capability of the interferometer allowed the reflectance measurements to be made in a timely fashion. The ellipsoidal mirror has its two foci separated by 2 inches and located on the major axis. A blackbody source was located at one focus while the tray clamp samples were located at the conjugate focus. The blackbody radiation was modulated and then focused by the ellipsoid onto the tray clamps. Radiation reflected from the tray clamp was sampled by the interferometer by viewing through a hole in the ellipsoid. A gold mirror (reflectance approximately 98 percent) was used as the reference surface.

  3. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromwell, B. K.; Shepherd, S. D.; Pender, C. W.; Wood, B. E.

    1993-01-01

    Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

  4. The LDEF ultra heavy cosmic ray experiment

    NASA Technical Reports Server (NTRS)

    Osullivan, D.; Thompson, A.; Bosch, J.; Keegan, R.; Wenzel, K.-P.; Smit, A.; Domingo, C.

    1991-01-01

    The Long Duration Exposure Facility (LDEF) Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of 4 pressure vessels (3 experiment tray). The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 2000 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Postflight work to date and the current status of the experiment are reviewed. Provisional results from analysis of preflight and postflight calibrations are presented.

  5. Comparison of Spacecraft Contamination Models with Well-Defined Flight Experiment

    NASA Technical Reports Server (NTRS)

    Pippin, G. H.

    1998-01-01

    The report presents analyzed surface areas on particular experiment trays from the Long Duration Exposure Facility (LDEF) for silicone-based molecular contamination. The trays for examination were part of the Ultra-Heavy Cosmic Ray Experiment (UHCRE). These particular trays were chosen because each tray was identical to the others in construction, and the materials on each tray were well known, documented, and characterized. In particular, a known specific source of silicone contamination was present on each tray. Only the exposure conditions varied from tray to tray. The results of post-flight analyses of surfaces of three trays were compared with the predictions of the three different spacecraft molecular contamination models. Phase one tasks included: 1) documenting the detailed geometry of the hardware; 2) determining essential properties of the anodized aluminum, Velcro(Tm), silverized Teflon(Tm), silicone gaskets, and DC6-1104(Tm) silicone adhesive materials used to make the trays, tray covers, and thermal control blankets; 3) selecting and removing areas from each tray; and 4) beginning surface analysis of the selected tray walls. Phase two tasks included: 1) completion of surface analysis measurements of the selected tray surface, 2) obtaining auger depth profiles at selected locations, and 3) running versions of the ISEM, MOFLUX, and PLIMP (Plume Impingement) contamination prediction models and making comparisons with experimental results.

  6. LDEF Materials/Contamination

    NASA Technical Reports Server (NTRS)

    Pippin, Gary

    1997-01-01

    This pictorial presentation reviews the post-flight analysis results from two type of hardware (tray clamp bolt heads and uhcre flight experiment tray walls) from the Long Duration Exposure Facility (LDEF). It will also discuss flight hardware for one upcoming (Effects of the Space Environment on Materials (ESEM) flight experiment), and two current flight experiments evaluating the performance of materials in space (Passive Optical Sample Assembly (POSA) 1&2 flight experiments. These flight experiments also are concerned with contamination effects which will also be discussed.

  7. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis

    PubMed Central

    John-Baptiste, A.; Sowerby, L.J.; Chin, C.J.; Martin, J.; Rotenberg, B.W.

    2016-01-01

    Background: When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). Methods: We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. Results: The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Interpretation: Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems. PMID:27975045

  8. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    PubMed

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  9. The LDEF ultra heavy cosmic ray experiment

    NASA Technical Reports Server (NTRS)

    Osullivan, D.; Thompson, A.; Bosch, J.; Keegan, R.; Wenzel, K.-P.; Smit, A.; Domingo, C.

    1992-01-01

    The LDEF Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of four in 48 pressure vessels. The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 1800 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Post flight work to date and the current status of the experiment are reviewed.

  10. Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material.

    PubMed

    Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu

    2009-07-01

    Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile

  11. Follow-up on the effects of the space environment on UHCRE thermal blankets

    NASA Technical Reports Server (NTRS)

    Levadou, Francois; Vaneesbeek, Marc

    1993-01-01

    An overview of the effects of the space environment on the thermal blanket of the UHCRE experiment is presented with an emphasis on atomic oxygen (AO) erosion. A more accurate value for FEP Teflon reaction efficiency is given and corresponds, at normal incidence, to 3.24 10(exp -25) cu cm/atomic, therefore, the FEP Teflon erosion corresponding to the Long Duration Exposure Facility (LDEF) total mission is 29.5 microns. A power 1.44 of the cosine of the incident angle of the oxygen atoms is found. It is shown that this value is not far from the power found using Fergusson's relationship between efficiency and energy of the O-atoms. An hypothesis concerning the effect of oxygen ions (O(+)) is also presented. The presence of oxygen ions may explain the different results obtained from different flights and from laboratory tests. Finally an XPS analysis of Chemglaze Z306(tm) black paint demonstrates the presence of silicone in the paint which may explain part of the contamination found on LDEF.

  12. STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes pinch bar, deadblow hammer, punch, inspection mirror, speed handle assembly, robbins wrench, adjustable wrench, vise grips, connector pliers, ACCU bypass connector, connector strap wrench, locker tool, and mechanical fingers. Photo taken by NASA JSC contract photographer Benny Benavides.

  13. Protein crystal growth tray assembly

    NASA Technical Reports Server (NTRS)

    Carter, Daniel C. (Inventor); Miller, Teresa Y. (Inventor)

    1992-01-01

    A protein crystal growth tray assembly includes a tray that has a plurality of individual crystal growth chambers. Each chamber has a movable pedestal which carries a protein crystal growth compartment at an upper end. The several pedestals for each tray assembly are ganged together for concurrent movement so that the solutions in the various pedestal growth compartments can be separated from the solutions in the tray's growth chambers until the experiment is to be activated.

  14. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants

    PubMed Central

    Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S

    2013-01-01

    Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130

  15. Space Shuttle food tray

    NASA Image and Video Library

    1983-11-28

    STS009-05-0153 (28 Nov. - 8 Dec. 1983) --- Though STS-9 was the space shuttle Columbia's sixth spaceflight, it was the first opportunity for an onboard galley, some of the results of which are shown in this 35mm scene on the flight deck. The metal tray makes for easy preparation and serving of in-space meals for crew members. This crewman is seated at the pilot's station on the flight deck. The actual galley is located in the middeck. Photo credit: NASA

  16. Flexible Interior-Impression-Molding Tray

    NASA Technical Reports Server (NTRS)

    Anders, Jeffrey E.

    1991-01-01

    Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.

  17. Distillation tray structural parameter study: Phase 1

    NASA Technical Reports Server (NTRS)

    Winter, J. Ronald

    1991-01-01

    The purpose here is to identify the structural parameters (plate thickness, liquid level, beam size, number of beams, tray diameter, etc.) that affect the structural integrity of distillation trays in distillation columns. Once the sensitivity of the trays' dynamic response to these parameters has been established, the designer will be able to use this information to prepare more accurate specifications for the construction of new trays. Information is given on both static and dynamic analysis, modal response, and tray failure details.

  18. STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.

  19. Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies.

    PubMed

    Arora, Mansi; Kohli, Shivani; Kalsi, Rupali

    2016-05-01

    Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials.

  20. Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies

    PubMed Central

    Kohli, Shivani; Kalsi, Rupali

    2016-01-01

    Introduction Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. Aim This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. Materials and Methods The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. Results The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. Conclusion The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials. PMID:27437342

  1. Develop and Manufacture an airlock sliding tray

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Cindy M.

    2014-02-26

    The goal of this project is to continue to develop an airlock sliding tray and then partner with an industrial manufacturing company for production. The sliding tray will be easily installed into and removed from most glovebox airlocks in a few minutes. Technical Approach: A prototype of a sliding tray has been developed and tested in the LANL cold lab and 35 trays are presently being built for the plutonium facility (PF-4). The current, recently approved design works for a 14-inch diameter round airlock and has a tray length of approximately 20 inches. The grant will take the already testedmore » and approved round technology and design for the square airlock. These two designs will be suitable for the majority of the existing airlocks in the multitude of DOE facilities. Partnering with an external manufacturer will allow for production of the airlock trays at a much lower cost and increase the availability of the product for all DOE sites. Project duration is estimated to be 12-13 months. Benefits: The purpose of the airlock sliding trays is fourfold: 1) Mitigate risk of rotator cuff injuries, 2) Improve ALARA, 3) Reduce risk of glovebox glove breaches and glove punctures, and 4) Improve worker comfort. I have had the opportunity to visit many other DOE facilities including Savannah, Y-12, ORNL, Sandia, and Livermore for assistance with ergonomic problems and/or injuries. All of these sites would benefit from the airlock sliding tray and I can assume all other DOE facilities with gloveboxes built prior to 1985 could also use the sliding trays.« less

  2. Silver Teflon blanket: LDEF tray C-08

    NASA Technical Reports Server (NTRS)

    Crutcher, E. Russ; Nishimura, L. S.; Warner, K. J.; Wascher, W. W.

    1992-01-01

    A study of the Teflon blanket surface at the edge of tray C-08 illustrates the complexity of the microenvironments on the Long Duration Exposure Facility (LDEF). The distribution of particulate contaminants varied dramatically over a distance of half a centimeter (quarter of an inch) near the edge of the blanket. The geometry and optical effects of the atomic oxygen erosion varied significantly over the few centimeters where the blanket folded over the edge of the tray resulting in a variety of orientations to the atomic oxygen flux. A very complex region of combined mechanical and atomic oxygen damage occurred where the blanket contacted the edge of the tray. A brown film deposit apparently fixed by ultraviolet light traveling by reflection through the Teflon film was conspicuous beyond the tray contract zone. Chemical and structural analysis of the surface of the brown film and beyond toward the protected edge of the blanket indicated some penetration of energetic atomic oxygen at least five millimeters past the blanket-tray contact interface.

  3. Progress report on the ultra heavy cosmic ray experiment (AO178)

    NASA Technical Reports Server (NTRS)

    Thompson, A.; Osullivan, D.; Bosch, J.; Keegan, R.; Wenzel, K.-P.; Jansen, F.; Domingo, C.

    1993-01-01

    The Ultra Heavy Cosmic Ray Experiment (UHCRE) is based on a modular array of 192 side-viewing solid state nuclear track detector stacks. These stacks were mounted in sets of four in 48 pressure vessels employing sixteen peripheral Long Duration Exposure Facility (LDEF) trays. The extended duration of the LDEF mission has resulted in a greatly enhanced scientific yield from the UHCRE. The geometry factor for high energy cosmic ray nuclei, allowing for Earth shadowing, was 30 sq m-sr, giving a total exposure factor of 170 sq m-sr-y at an orbital inclination of 28.4 degrees. Scanning results indicate that about 3000 cosmic ray nuclei in the charge region with Z greater than 65 were collected. This sample is more than ten times the current world data in the field (taken to be the data set from the HEAO-3 mission plus that from the Ariel-6 mission) and is sufficient to provide the world's first statistically significant sample of actinide (Z greater than 88) cosmic rays. Results to date are presented including details of ultra-heavy cosmic ray nuclei, analysis of pre-flight and post-flight calibration events and details of track response in the context of detector temperature history. The integrated effect of all temperature and age related latent track variations cause a maximum charge shift of +/- 0.8 e for uranium and +/- 0.6 e for the platinum-lead group. The precision of charge assignment as a function of energy is derived and evidence for remarkably good charge resolution achieved in the UHCRE is considered. Astrophysical implications of the UHCRE charge spectrum are discussed.

  4. Clinical evaluation of final impressions from three-dimensional printed custom trays.

    PubMed

    Sun, Yuchun; Chen, Hu; Li, Hong; Deng, Kehui; Zhao, Tian; Wang, Yong; Zhou, Yongsheng

    2017-11-02

    This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocurable materials were produced as controls. Both 3D printed custom trays and manually made ones were used to take impressions from edentulous patients. After 3D scanning of the final impression, the impression materials were removed, thus the underneath tray surfaces were able to be scanned, allowing the thickness of the impression materials to be measured. Final impressions obtained by pre-border-molded 3D printed trays were scanned as references, to which the flange extension deviations and morphology deviations of the impressions taken by both 3D printed trays and manually made ones were calculated. The results showed that (1) impressions from 3D printed custom trays had better thickness distribution than that of manually made ones; (2) impression morphology deviations in non-marginal area were neither statistic different between 3D printed trays and manually made trays, nor between trays with and without tissue stops; and (3) final impressions taken by custom trays without pre-border-molding were tended to have insufficient flange extensions.

  5. View of food tray to be used in Skylab program

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A close-up view of a food tray which is scheduled to be used in the Skylab program. Several packages of space food lie beside the tray. The food in the tray is ready to eat. Out of tray, starting from bottom left: grape drink, beef pot roast, chicken and rice, beef sandwiches and sugar cookie cubes, In tray, from back left: orange drink, strawberries, asparagus, prime rib, dinner roll and butterscotch pudding in the center.

  6. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  7. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  8. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  9. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  10. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  11. Unilateral neglect: further validation of the baking tray task.

    PubMed

    Appelros, Peter; Karlsson, Gunnel M; Thorwalls, Annika; Tham, Kerstin; Nydevik, Ingegerd

    2004-11-01

    The Baking Tray Task is a comprehensible, simple-to-perform test for use in assessing unilateral neglect. The aim of this study was to validate further its use with stroke patients. The Baking Tray Task was compared with 2 versions of the Behaviour Inattention Test and a test for personal neglect. A total of 270 patients were subjected to a 3-item version of the Behaviour Inattention Test and 40 patients were subjected to an 8-item version of the Behaviour Inattention Test, besides the Baking Tray Task and the personal neglect test. The Baking Tray Task was more sensitive than the 3-item Behaviour Inattention Test, but the 8-item Behaviour Inattention Test was more sensitive than the Baking Tray Task. The best combination of any 3 tests was Baking Tray Task, Reading an article, and Figure copying; the 2 last-mentioned being a part of the 8-item Behaviour Inattention Test. Multi-item tests detect more cases of neglect than do single tests. However, it is tiresome for the patient to undergo a larger test battery than necessary. It is also time-consuming for the staff. Behavioural tests seem more appropriate when assessing neglect. The Baking Tray Task seems to be one of the most sensitive single tests, but its sensitivity can be further enhanced when it is used in combination with other tests.

  12. Surface characterization of selected LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromer, T. F.; Grammer, H. L.; Wightman, J. P.; Young, Philip R.; Slemp, Wayne S.

    1993-01-01

    The surface characterization of chromic acid anodized 6061-T6 aluminum alloy tray clamps has shown differences in surface chemistry depending upon the position on the Long Duration Exposure Facility (LDEF). Water contact angle results showed no changes in wettability of the tray clamps. The overall surface topography of the control, trailing edge(E3) and leading edge(D9) samples was similar. The thickness of the aluminum oxide layer for all samples determined by Auger depth profiling was less than one micron. X-ray photoelectron spectroscopy (XPS) analysis of the tray clamps showed significant differences in the surface composition. Carbon and silicon containing compounds were the primary contaminants detected.

  13. Non Destructive Seal Testing Polymeric Tray

    DTIC Science & Technology

    2006-10-01

    School of Enviromental and Biological Science Rutgers, The State University of New Jersey New Brunswick, New Jersey 08903 Principal Investigator...plate to accept new tray • Insert tray • Push “Continue” button • Lower upper compression plate and hold in position (80 psig) • Raise bottom...John J. Kingman Rd. Fort Belvoir, VA 22060-6221 Contractor: Rutgers, The State University of New Jersey THE CENTER FOR ADVANCED FOOD TECHNOLOGY

  14. In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study

    PubMed Central

    Gupta, Sonam; Balakrishnan, Dhanasekar

    2017-01-01

    Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n = 5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p < 0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p > 0.05) was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials. PMID:28348595

  15. Aeroelastic Response and Protection of Space Shuttle External Tank Cable Trays

    NASA Technical Reports Server (NTRS)

    Edwards, John W.; Keller, Donald F.; Schuster, David M.; Piatak, David J.; Rausch, Russ D.; Bartels, Robert E.; Ivanco, Thomas G.; Cole, Stanley R.; Spain, Charles V.

    2005-01-01

    Sections of the Space Shuttle External Tank Liquid Oxygen (LO2) and Liquid Hydrogen (LH2) cable trays are shielded from potentially damaging airloads with foam Protuberance Aerodynamic Load (PAL) Ramps. Flight standard design LO2 and LH2 cable tray sections were tested with and without PAL Ramp models in the United States Air Force Arnold Engineering Development Center s (AEDC) 16T transonic wind tunnel to obtain experimental data on the aeroelastic stability and response characteristics of the trays and as part of the larger effort to determine whether the PAL ramps can be safely modified or removed. Computational Fluid Dynamic simulations of the full-stack shuttle launch configuration were used to investigate the flow characeristics around and under the cable trays without the protective PAL ramps and to define maximum crossflow Mach numbers and dynamic pressures experienced during launch. These crossflow conditions were used to establish wind tunnel test conditions which also included conservative margins. For all of the conditions and configurations tested, no aeroelastic instabilities or unacceptable dynamic response levels were encountered and no visible structural damage was experienced by any of the tested cable tray sections. Based upon this aeroelastic characterization test, three potentially acceptable alternatives are available for the LO2 cable tray PAL Ramps: Mini-Ramps, Tray Fences, or No Ramps. All configurations were tested to maximum conditions, except the LH2 trays at -15 deg. crossflow angle. This exception is the only caveat preventing the proposal of acceptable alternative configurations for the LH2 trays as well. Structural assessment of all tray loads and tray response measurements from launches following the Shuttle Return To Flight with the existing PAL Ramps will determine the acceptability of these PAL Ramp alternatives.

  16. Heat and Mass Transfer Measurements for Tray-Fermented Fungal Products

    NASA Astrophysics Data System (ADS)

    Jou, R.-Y.; Lo, C.-T.

    2011-01-01

    In this study, heat and mass transfer in static tray fermentation, which is widely used in solid-state fermentation (SSF) to produce fungal products, such as enzymes or koji, is investigated. Specifically, kinetic models of transport phenomena in the whole-tray chamber are emphasized. The effects of temperature, moisture, and humidity on microbial growth in large-scale static tray fermentation are essential to scale-up SSF and achieve uniform fermentation. In addition, heat and mass transfer of static tray fermentation of Trichoderma fungi with two tray setups—traditional linen coverings and stacks in a temperature-humidity chamber is examined. In both these setups, the following factors of fermentation were measured: air velocity, air temperature, illumination, pH, carbon dioxide (CO2) concentration, and substrate temperature, and the effects of bed height, moisture of substrate, and relative humidity of air are studied. A thin (1 cm) bed at 28 °C and 95 % relative humidity is found to be optimum. Furthermore, mixing was essential for achieving uniform fermentation of Trichoderma fungi. This study has important applications in large-scale static tray fermentation of fungi.

  17. MISSE 1 and 2 Tray Temperature Measurements

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Kinard, William H.

    2006-01-01

    The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.

  18. 21 CFR 872.3670 - Resin impression tray material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...

  19. 21 CFR 872.3670 - Resin impression tray material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...

  20. Skylab Food Heating and Serving Tray

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Shown here is the Skylab food heating and serving tray with food, drink, and utensils. The tray contained heating elements for preparing the individual food packets. The food on Skylab was a great improvement over that on earlier spaceflights. It was no longer necessary to squeeze liquified food from plastic tubes. Skylab's kitchen in the Orbital Workshop wardroom was so equipped that each crewman could select his own menu and prepare it to his own taste. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  1. T-ray tomography.

    PubMed

    Mittleman, D M; Hunsche, S; Boivin, L; Nuss, M C

    1997-06-15

    We demonstrate tomographic T-ray imaging, using the timing information present in terahertz (THz) pulses in a reflection geometry. THz pulses are reflected from refractive-index discontinuities inside an object, and the time delays of these pulses are used to determine the positions of the discontinuities along the propagation direction. In this fashion a tomographic image can be constructed.

  2. Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

    PubMed Central

    Pastoret, Marie-Hélène; Bühler, Julia; Weiger, Roland

    2017-01-01

    PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth. PMID:28874996

  3. Tray estimates for low reflux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barna, B.A.; Ginn, R.F.

    1985-05-01

    In computer programs which perform shortcut calculations for multicomponent distillation, the Gilliland correlation continues to be used even though errors of up to 60% (compared with rigorous plate-to-plate calculations) were shown by Erbar and Maddox. Average absolute differences were approximately 30% for Gilliland's correlation versus 4% for the Erbar-Maddox method. The reason the Gilliland correlation continues to be used appears to be due to the availability of an equation by Eduljee which facilitates the correlation's use in computer program. A new equation is presented in this paper that represents the Erbar-Maddox correlation of trays with reflux for multicomponent distillation. Atmore » low reflux ratios, results show more trays are needed than would be estimated by Gilliland's method.« less

  4. Accuracy of a self-perforating impression tray for dental implants.

    PubMed

    Marotti, Juliana; Tortamano, Pedro; Castilho, Tatiana R R N; Steagall, Washington; Wolfart, Stefan; Haselhuhn, Klaus

    2014-10-01

    Difficulties are involved in impression making with conventional open impression trays. The purpose of this study was to evaluate the accuracy of transferring implant impressions with a self-perforating impression tray. A reference model of a mandible was fabricated, and 4 implants were placed in the regions of the first premolars and lateral incisors (implants 1, 2, 3, 4). Ten impressions of the reference model with polyvinyl siloxane were made for each group; control (conventional open impression tray) and test (self-perforating impression tray; Miratray Implant). A metal bar was screw-retained on implant 1, and the gaps generated at the vestibular face of implants 3 and 4 were measured by optical microcopy. The 2-way ANOVA and least square difference post hoc test were used (α=.05). Higher mean (±SD) values were obtained for the test group than for the control group for both implants: implant 3: 150 ±84 μm for the test group, 73 ±63 μm for the control group (P=.019); implant 4: 129 ±65 μm for the test group, 62 ±61 μm for the control group (P=.04). The self-perforating impression tray provided less accuracy than the conventional open tray. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Applications of T-ray spectroscopy in the petroleum field

    NASA Astrophysics Data System (ADS)

    Al-Douseri, Fatemah M.

    2005-11-01

    Because of heavy usage of petroleum products, which are the main source of energy in daily life and industry, a fast, reliable, and portable analysis system is needed to complement traditional techniques. Terahertz (THz) radiation, or T-rays, is electromagnetic radiation in the 0.1 to 10 THz frequency range. One unique attribute of T-rays is their ability to sensitively measure the induced molecular dipole moments in non-polar liquids such as aromatics, which make up the majority of the contents of many petroleum products. This information can lead to several applications in petroleum analysis. The application of T-rays to petroleum product analysis has the potential to make a significant impact in the petroleum field. In this dissertation, I show the first use of T-ray time-domain spectroscopy and Fourier transform infrared (FTIR) spectroscopy techniques for petroleum product analysis. I report on the feasibility of analyzing selected petroleum products, including gasoline, diesel, lubricating oil, and selected compounds of toluene, ethylbenzene, and xylene (BTEX). With the use of a T-ray time-domain spectrometer. I demonstrate that gasolines with different octane numbers and diesel all show specific absorption coefficients and refractive indexes in the spectral range from 0.5 to 2.0 THz. Furthermore, I report the qualitative and quantitative analysis of selected BTEX components in gasoline and diesel using FTIR spectroscopy in the 50 to 650 cm-1 region. I distinguish gasolines with different octane numbers from diesel and lubricating oil according to their different spectral features. I also determine the concentration of (o, m, p) xylene isomers in gasoline according to their specific absorption bands. The experimental results in this thesis, imply that linking between the knowledge of petroleum products and the development of T-ray spectrometer with the cooperation of industry might translate the T-ray spectroscopic system into a real world application in

  6. Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions.

    PubMed

    Hoyos, Alex; Soderholm, Karl-Johan

    2011-01-01

    The aim of this study was to determine how tray rigidity and impression technique affect the accuracy of polyvinyl siloxane impressions. Disposable plastic trays and metallic Rim-Lock trays were used in combination with a heavy/light body technique or with two different putty-wash techniques. For each technique-tray combination, 10 impressions were made of a master cast with two steel abutments representing the mandibular right first premolar and second molar, between which a steel rod was placed at the ridge level. Each steel abutment had five marks, while the steel rod in between the two abutments had only one mark, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were recorded for each mark on the master cast and impressions. The distances between the different marks and the reference point on the impressions were calculated and compared with those of the master cast. All techniques used with the plastic trays had distances that were significantly different from the master cast (P < .05), while for the metal trays, it was only the heavy/light body technique that resulted in distances that were significantly different from the master cast (P < .05). Plastic trays produced less accurate impressions than metal trays. When metal trays were used, putty-based impressions were dimensionally better than heavy/light body impressions.

  7. TRAY MOUNTAIN ROADLESS AREA, GEORGIA.

    USGS Publications Warehouse

    Nelson, Arthur E.; Chatman, Mark L.

    1984-01-01

    A mineral survey indicates that the Tray Mountain Roadless Area, Georgia has little promise for the occurrence of metallic mineral resources. Rocks underlying the Tray Mountain Roadless Area are suitable for crushed rock or aggregate; however, other sources for these materials are available closer to present markets. There is a possibility for the occurrence of hydrocarbon resources underlying the area at great depth, but no hydrocarbon potential was identified. Detailed studies are needed to establish the presence or absence and mineral-resource potential of olivine, nickel, cobalt, and chrome in the two mafic-ultramafic bodies in the Hayesville thrust sheet. The cause of the lead anomaly in pan concentrate samples taken from the southwest part of the roadless area has not been established; the mineral residence and source of the anomaly remain to be determined.

  8. 106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770), TOWARDS CABLE TRAY SHED - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  9. Image Processing Techniques for Assessment of Dental Trays

    DTIC Science & Technology

    2001-10-25

    170 patients having Angle Class I molar relationships with minor malocclusions and teeth including second molars fully erupted without loss of tooth...Abstract-A tray selected for the dental patient must adapt to the curvature of the teeth and allow the impression material to be in appropriate...brands of perforated metal trays with 170 lower arch cast models collected from patients having Angle Class 1 type occlusion with minor malocclusions

  10. SSET Project: Cost-effectiveness Analysis of Surgical Specialty Emergency Trays in the Emergency Department.

    PubMed

    Humphries, Laura S; Shenaq, Deana S; Teven, Chad M; Park, Julie E; Song, David H

    2018-01-01

    We hypothesize that reusable, on-site specialty instrument trays available to plastic surgery residents in the emergency department (ED) for bedside procedures are more cost-effective than disposable on-site and remote re-usable operating room (OR) instruments at our institution. We completed a cost-effectiveness analysis comparing the use of disposable on-site kits and remote OR trays to a hypothetical, custom, reusable tray for ED procedures completed by PRS residents. Material costs of existing OR trays were used to estimate the purchasing and use-cost of a custom on-site tray for the same procedures. Cost of per procedure 'consult time' was estimated using procedure and resident salary. Sixteen bedside procedures were completed over a 4.5 month period. A mean of 2.14 disposable kits were used per-procedure. Mean consultation time was 1.66 hours. Procedures that used OR trays took 3 times as long as procedures that used on-site kits (4 vs. 1.1 hours). Necessary, additional instruments were unavailable for 75% of procedures. Mean cost of using disposable kits and OR trays was $115.03/procedure versus an estimated $26.67/procedure cost of using a custom tray, yielding $88.36/procedure cost-savings. Purchase of a single custom tray ($1,421.55) would be redeemed after 2.3 weeks at 1 procedure/day. Purchasing 4 trays has projected annual cost-savings of $26,565.20. The purchase of specialized procedure trays will yield valuable time and cost-savings while providing quality patient care. Improving time efficiency will help achieve the Accreditation Council of Graduate Medical Education (ACGME) goals of maintaining resident well-being and developing quality improvement competency.

  11. Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays

    PubMed Central

    Chen, Hu; Yang, Xu; Chen, Litong; Wang, Yong; Sun, Yuchun

    2016-01-01

    The objective was to establish and evaluate a method for manufacture of custom trays for edentulous jaws using computer aided design and fused deposition modeling (FDM) technologies. A digital method for design the custom trays for edentulous jaws was established. The tissue surface data of ten standard mandibular edentulous plaster models, which was used to design the digital custom tray in a reverse engineering software, were obtained using a 3D scanner. The designed tray was printed by a 3D FDM printing device. Another ten hand-made custom trays were produced as control. The 3-dimentional surface data of models and custom trays was scanned to evaluate the accuracy of reserved impression space, while the difference between digitally made trays and hand-made trays were analyzed. The digitally made custom trays achieved a good matching with the mandibular model, showing higher accuracy than the hand-made ones. There was no significant difference of the reserved space between different models and its matched digitally made trays. With 3D scanning, CAD and FDM technology, an efficient method of custom tray production was established, which achieved a high reproducibility and accuracy. PMID:26763620

  12. Skylab Food Heating and Serving Tray

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Shown here is the Skylab food heating and serving tray in its stowed position. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  13. STS-5 crewmembers with meal tray assembly on middeck

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Commander Brand (in dark blue shirt), Pilot Overmyer (left), and Mission Specialist (MS) Lenoir (right) conduct microgravity experiments with food containers and meal tray assemblies in front of middeck port side wall and side hatch. Brand prepares to eat as meal tray assembly floats above his chest and Overmeyer and Lenoir look on. Sign on port side wall is labeled STS-5 Message Board.

  14. Bleaching and temporomandibular disorder using a half tray design: a clinical report.

    PubMed

    Robinson, F G; Haywood, V B

    2000-05-01

    A maxillary soft, custom-fitted tray was fabricated for a patient to perform nightguard vital bleaching. Treatment was interrupted after the patient experienced pain in the temporomandibular joint area shortly after wearing the bleaching prosthesis. The tray was trimmed so the labial, incisal and buccal cusps were covered and Sc) the patient had complete tooth-to-tooth contact in the maximum intercuspal position. The prosthesis proved to be retentive even without the presence of the bleaching material. The thick, sticky bleaching material was contained in the half tray design and the tray was held in place. The patient was able to continue the bleaching process for the 2-week duration necessary to achieve successful lightening of the teeth without further TMD symptoms.

  15. Will Tray Rations be Available for the Next War?

    DTIC Science & Technology

    1990-03-18

    industry giants into the competition. Companies like Pillsbury and Green Giant competed for the opportunity to enter the T- Ration market.5 However...document may not be released for open pubicatio and it hu been cleaed by dw appmpriat militay ase or Ipoemment alency. WILL TRAY RATIONS BE AVAILABLE...TITLE (and Subtitle) -- T yPE OF REPORT & PERIOD COVERED Will Tray Rations Be Available For the Next War? Study Project 6. PERFORMING ORG. REPORT

  16. Overhead tray for cable test system

    NASA Technical Reports Server (NTRS)

    Saltz, K. T.

    1976-01-01

    System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.

  17. A New Idea for Dissecting Tray

    ERIC Educational Resources Information Center

    Branham, Arthur

    1976-01-01

    A method of preparing a special dissecting tray to be used with transmitted light as well as reflected light is presented. It may also be used with an overhead projector to illustrate some skeletal structures in vertebrates. (Author/EB)

  18. A comparative study of inter-abutment distance of dies made from full arch dual-arch impression trays with those made from full arch stock trays: an in vitro study.

    PubMed

    Reddy, Jagan Mohan; Prashanti, E; Kumar, G Vinay; Suresh Sajjan, M C; Mathew, Xavier

    2009-01-01

    The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature. This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.

  19. Polylactic acid trays for fresh-food packaging: A Carbon Footprint assessment.

    PubMed

    Ingrao, Carlo; Tricase, Caterina; Cholewa-Wójcik, Agnieszka; Kawecka, Agnieszka; Rana, Roberto; Siracusa, Valentina

    2015-12-15

    This paper discusses application of Carbon Footprint (CF) for quantification of the 100-year Global Warming Potential (GWP100) associated with the life cycle of polylactic acid (PLA) trays for packaging of fresh foods. A comparison with polystyrene (PS)-based trays was done considering two different transport system scenarios for PLA-granule supply to the tray production firm: a transoceanic freight vessel and an intercontinental freight aircraft. Doing so enabled estimation of the influence of the transportation phase on the GHG-emission rate associated with the PLA-trays' life cycle. From the assessment, the GWP100 resulted to be mainly due to PLA-granulate production and to its transportation to the tray manufacturing facility. Also, the study documented that, depending upon the transport system considered, the CF associated with the life cycle of the PLA trays can worsen so much that the latter are no longer GHG-emission saving as they are expected to be compared to the PS ones. Therefore, based upon the findings of the study, it was possible for the authors to understand the importance and the need of accounting for the transport-related issues in the design of PLA-based products, thus preserving their environmental soundness compared to traditional petroleum-based products. In this context, the study could be used as the base to reconsider the merits of PLA usage for product manufacturing, especially when high distances are implied, as in this analysed case. So, the authors believe that new research and policy frameworks should be designed and implemented for both development and promotion of more globally sustainable options. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Scooped Material on Rover Observation Tray

    NASA Image and Video Library

    2012-10-25

    Sample material from the fourth scoop of Martian soil collected by NASA Mars rover Curiosity is on the rover observation tray in this image taken during the mission 78th Martian sol, Oct. 24, 2012 by Curiosity left Navigation Camera.

  1. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.

    PubMed

    Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F

    2009-12-01

    The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (P<.001). Impressions made with Sultan trays were significantly less accurate than impressions made with First Bite or Premium impression trays. The Premium tray type had the highest mean (SD) GSV

  2. Scanning electron microscope/energy dispersive x ray analysis of impact residues in LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1993-01-01

    Detailed optical scanning of tray clamps is being conducted in the Facility for the Optical Inspection of Large Surfaces at JSC to locate and document impacts as small as 40 microns in diameter. Residues from selected impacts are then being characterized by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis at CNES. Results from this analysis will be the initial step to classifying projectile residues into specific sources.

  3. Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H

    2017-01-01

    Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Assessing the magnitude and costs of intraoperative inefficiencies attributable to surgical instrument trays.

    PubMed

    Stockert, Emily Walker; Langerman, Alexander

    2014-10-01

    Efficiency in the operating room has become a topic of great interest. This study aimed to quantify the percent use of instruments among common instrument trays across 4 busy surgical services: Otolaryngology, Plastic Surgery, Bariatric Surgery, and Neurosurgery. We further aimed to calculate the costs associated with tray and instrument sterilization, as well as the implications of missing or damaged instruments. This was a single-site, observational study conducted on the surgical instrumentation at a large academic medical center in Chicago. Data were collected through direct observation by a trained investigator. Operating room instrument use and labor time required for cleaning and repacking instrument trays in central sterile processing (CSP) were analyzed using descriptive statistics and linear regression. Institutional data on volume and expenses were gathered from hospital leadership. Forty-nine procedures and 237 individual trays were observed. Average instrument (±SD)use rates were 13.0% for Otolaryngology (±4.2%), 15.5% for Plastic Surgery (±2.9%), 18.2% for Bariatric Surgery (±5.0%), and 21.9% for Neurosurgery (±1.7%). An increasing number of instruments per tray was associated with decreased use and increased instrument error rate. Using recorded labor time, the cost of cleaning and repackaging an individual instrument was calculated to be $0.10. Adding in CSP operating expenses and instrument depreciation per use, total processing cost per instrument increases to $0.51 or more. Our study demonstrates that the percent use of instruments across surgical specialties and multiple tray types is low. Attention to tray composition may result in immediate and significant cost savings. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  5. The Skills Minister's In-Tray

    ERIC Educational Resources Information Center

    Hancock's, Matthew

    2012-01-01

    In the "Adults Learning" autumn issue, the journal staff asked key players in the learning and skills sector what they thought should be at the top of new skills minister Matthew Hancock's in-tray. The new minister shares that his job in the further education and skills sector is to rise to the challenge and play his full part in giving…

  6. Compact sieve-tray distillation column for ammonia-water absorption heat pump: Part 1 -- Design methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, G.; Erickson, D.C.

    1999-07-01

    The distillation column is a key component of ammonia-water absorption units including advanced generator-absorber heat exchange (GAX) cycle heat pumps. The design of the distillation column is critical to unit performance, size, and cost. The distillation column can be designed with random packing, structured packing, or various tray configurations. A sieve-tray distillation column is the least complicated tray design and is less costly than high-efficiency packing. Substantial literature is available on sieve tray design and performance. However, most of the correlations and design recommendations were developed for large industrial hydrocarbon systems and are generally not directly applicable to the compactmore » ammonia-water column discussed here. The correlations were reviewed and modified as appropriate for this application, and a sieve-tray design model was developed. This paper presents the sieve-tray design methodology for highly compact ammonia-water columns. A conceptual design of the distillation column for an 8 ton vapor exchange (VX) GAX heat pump is presented, illustrating relevant design parameters and trends. The design process revealed several issues that have to be investigated experimentally to design the final optimized rectifier. Validation of flooding and weeping limits and tray/point efficiencies are of primary importance.« less

  7. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    PubMed

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  8. Novel method of fabricating individual trays for maxillectomy patients by computer-aided design and rapid prototyping.

    PubMed

    Huang, Zhi; Wang, Xin-zhi; Hou, Yue-Zhong

    2015-02-01

    Making impressions for maxillectomy patients is an essential but difficult task. This study developed a novel method to fabricate individual trays by computer-aided design (CAD) and rapid prototyping (RP) to simplify the process and enhance patient safety. Five unilateral maxillectomy patients were recruited for this study. For each patient, a computed tomography (CT) scan was taken. Based on the 3D surface reconstruction of the target area, an individual tray was manufactured by CAD/RP. With a conventional custom tray as control, two final impressions were made using the different types of tray for each patient. The trays were sectioned, and in each section the thickness of the material was measured at six evenly distributed points. Descriptive statistics and paired t-test were used to examine the difference of the impression thickness. SAS 9.3 was applied in the statistical analysis. Afterwards, all casts were then optically 3D scanned and compared digitally to evaluate the feasibility of this method. Impressions of all five maxillectomy patients were successfully made with individual trays fabricated by CAD/RP and traditional trays. The descriptive statistics of impression thickness measurement showed slightly more uneven results in the traditional trays, but no statistical significance was shown. A 3D digital comparison showed acceptable discrepancies within 1 mm in the majority of cast areas. The largest difference of 3 mm was observed in the buccal wall of the defective areas. Moderate deviations of 1 to 2 mm were detected in the buccal and labial vestibular groove areas. This study confirmed the feasibility of a novel method of fabricating individual trays by CAD/RP. Impressions made by individual trays manufactured using CAD/RP had a uniform thickness, with an acceptable level of accuracy compared to those made through conventional processes. © 2014 by the American College of Prosthodontists.

  9. [Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture].

    PubMed

    Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X

    2017-02-18

    To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time

  10. Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification

    NASA Astrophysics Data System (ADS)

    Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas

    2015-03-01

    A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.

  11. Efficacy of tray adhesives for the adhesion of elastomer rubber impression materials to impression modeling plastics for border molding.

    PubMed

    Nishigawa, G; Sato, T; Suenaga, K; Minagi, S

    1998-02-01

    Tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, lowers the retention of the impression materials to the impression modeling plastics, as some ingredients of tray adhesive make the impression modeling plastic soft and tacky. The efficacy of tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, on the adhesion between elastomer rubber impression material and impression modeling plastic was investigated. Four silicone rubber impression materials (two addition reaction types and two condensation reaction types), two polysulfide rubber impression materials, and one impression modeling plastic were used in this study. Tensile strength between elastomer rubber impression material and impression modeling plastic with or without the application of tray adhesive was evaluated. Although tray adhesives for both addition reaction type and both condensation reaction type of silicone impression materials and one tray adhesive for polysulfide rubber impression material increased the tensile strength between the impression material and impression modeling plastic, one tray adhesive for polysulfide rubber impression material decreased the tensile strength when sufficient drying time was not applied.

  12. T-ray relevant frequencies for osteosarcoma classification

    NASA Astrophysics Data System (ADS)

    Withayachumnankul, W.; Ferguson, B.; Rainsford, T.; Findlay, D.; Mickan, S. P.; Abbott, D.

    2006-01-01

    We investigate the classification of the T-ray response of normal human bone cells and human osteosarcoma cells, grown in culture. Given the magnitude and phase responses within a reliable spectral range as features for input vectors, a trained support vector machine can correctly classify the two cell types to some extent. Performance of the support vector machine is deteriorated by the curse of dimensionality, resulting from the comparatively large number of features in the input vectors. Feature subset selection methods are used to select only an optimal number of relevant features for inputs. As a result, an improvement in generalization performance is attainable, and the selected frequencies can be used for further describing different mechanisms of the cells, responding to T-rays. We demonstrate a consistent classification accuracy of 89.6%, while the only one fifth of the original features are retained in the data set.

  13. Tropical field performance of dual-pass PV tray dryer

    NASA Astrophysics Data System (ADS)

    Iskandar, A. Noor; Ya'acob, M. E.; Anuar, M. S.

    2017-09-01

    Solar Photovoltaic technology has become the preferable solution in many countries around the globe to solve the ever increasing energy demand of the consumers. In line with the consumer need, food processing technology has huge potentials of integration with the renewable energy resources especially in drying process which consumes the highest electricity loads. Traditionally, the solar dryer technology was applied in agriculture and food industries utilizing the sun's energy for drying process, but this is highly dependable on the weather condition and surrounding factors. This work shares some field performance of the new design of portable dual-pass PV tray dryer for drying crops in an enclosed system. The dual-pass PV tray dryer encompass a lightweight aluminium box structure with dimensions of 1.1m (L) x 0.6m (W) x 0.2m (H) and can hold a load capacity of 300g - 3kg of crop depending on the types of the crops. Experiments of field performance monitoring were conducted in October -November 2016 which justifies a considerable reduction in time and crops quality improvement when using the dual-pass PV tray dryer as compared to direct-sun drying.

  14. Some results of the oxidation investigation of copper and silver samples flown on LDEF

    NASA Technical Reports Server (NTRS)

    Derooij, A.

    1992-01-01

    The Long Duration Exposure Facility (LDEF) Mission provides a unique opportunity to study the long term effects of the space environment on materials. The LDEF has been deployed in orbit on 7 April 1984 by the shuttle Challenger in an almost circular orbit with a mean altitude of 477 km and an inclination of 28.5 degrees. It was retrieved from its decayed orbit of 335 km by the shuttle Columbia on 12 January 1990 after almost 6 years in space. The LDEF is a 12-sided, 4.267 m diameter, and 9.144 m long structure. The experiments, placed on trays, are attached to the twelve sides and the two ends of the spacecraft. The LDEF was passively stabilized with one end of the spacecraft always pointing towards the earth center and one of the sides (row 9) always facing the flight direction. The materials investigated originate from the Ultra-Heavy Cosmic Ray Experiment (UHCRE). The main objective is a detailed study of the charge spectra of ultraheavy cosmic-ray nuclei from zinc to uranium and beyond, using solid-state track detectors. Besides the aluminium alloy used for the experiment, UHCRE comprises several other materials. The results of space exposure for two of them, the copper grounding strips and the thermal covers (FEP Teflon/Ag/Inconel) painted black on the inner side (Chemglaze Z306), are presented.

  15. Ultra heavy cosmic ray experiment (A0178)

    NASA Technical Reports Server (NTRS)

    Thompson, A.; Osullivan, D.; Bosch, J.; Keegan, R.; Wenzel, K. P.; Jansen, F.; Domingo, C.

    1992-01-01

    The Ultra Heavy Cosmic Ray Experiment (UHCRE) is based on a modular array of 192 side viewing solid state nuclear track detector stacks. These stacks were mounted in sets of four in 48 pressure vessels using 16 peripheral LDEF trays. The geometry factor for high energy cosmic ray nuclei, allowing for Earth shadowing, was 30 sq m sr, giving a total exposure factor of 170 sq m sr y at an orbital inclination of 28.4 degs. Scanning results indicate that about 3000 cosmic ray nuclei in the charge region with Z greater than 65 were collected. This sample is more than ten times the current world data in the field (taken to be the data set from the HEAO-3 mission plus that from the Ariel-6 mission) and is sufficient to provide the world's first statistically significant sample of actinide cosmic rays. Results are presented including a sample of ultra heavy cosmic ray nuclei, analysis of pre-flight and post-flight calibration events and details of track response in the context of detector temperature history. The integrated effect of all temperature and age related latent track variations cause a maximum charge shift of + or - 0.8e for uranium and + or - 0.6e for the platinum-lead group. Astrophysical implications of the UHCRE charge spectrum are discussed.

  16. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

    PubMed

    Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph

    2017-12-29

    To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.

  17. R-process Element Cosmic Rays from Neutron Star Mergers

    NASA Astrophysics Data System (ADS)

    Komiya, Yutaka; Shigeyama, Toshikazu

    2017-09-01

    Neutron star mergers (NSMs) are one of the most plausible sources of r-process elements in the universe. Therefore, NSMs can also be a major source of ultra-heavy elements in cosmic rays. In this paper, we first estimate the contribution of r-process elements synthesized in NSMs to the ultra-heavy element cosmic rays (UHCRs) by calculating transport equations that take into account energy loss processes and spallations. We show that the flux of UHCRs accelerated by the NSMs themselves fluctuates by many orders of magnitude on a timescale of several million years and can overwhelm UHCRs accelerated by supernova remnants (SNRs) after an NSM takes place within a few kiloparsec from the solar system. Experiments with very long exposure times using meteorites as UHCR detectors can detect this fluctuation. As a consequence, we show that if NSMs are the primary source of UHCRs, future experiments using meteorites may be able to reveal the event history of NSMs in the solar vicinity. We also describe a possible difference in the abundance pattern and energy spectrum of UHCRs between NSM and SNR accelerations.

  18. Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.

    PubMed

    Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke

    2018-03-16

    This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.

  19. Challenges to validation of a complex nonsterile medical device tray.

    PubMed

    Prince, Daniel; Mastej, Jozef; Hoverman, Isabel; Chatterjee, Raja; Easton, Diana; Behzad, Daniela

    2014-01-01

    Validation by steam sterilization of reusable medical devices requires careful attention to many parameters that directly influence whether or not complete sterilization occurs. Complex implant/instrument tray systems have a variety of configurations and components. Geobacillus stearothermophilus biological indicators (BIs) are used in overkill cycles to to simulate worst case conditions and are intended to provide substantial sterilization assurance. Survival of G. stearothermophilus spores was linked to steam access and size of load in the chamber. By a small and reproducible margin, it was determined that placement of the trays in a rigid container into minimally loaded chambers were more difficult to completely sterilize than maximally loaded chambers.

  20. Herbal dryer: drying of ginger (zingiber officinale) using tray dryer

    NASA Astrophysics Data System (ADS)

    Haryanto, B.; Hasibuan, R.; Alexander; Ashari, M.; Ridha, M.

    2018-02-01

    Drying is widely used as a method to preserve food because of its convenience and affordability. Drying of ginger using tray dryer were carried out at various drying conditions, such as air-drying flow, air-drying temperature, and sample dimensions, to achieve the highest drying rate. Samples with various dimensions were placed in the tray dryer and dried using various air-drying flow and temperatures. The weights of samples were observed every 3 minutes interval. Drying was stopped after three times of constant weighing. Data of drying was collected to make the drying curves. Drying curves show that the highest drying rate is achieved using highest air flow and temperature.

  1. Recolonization of macrofauna in unpolluted sands placed in a polluted yachting harbour: A field approach using experimental trays

    NASA Astrophysics Data System (ADS)

    Guerra-García, J. M.; García-Gómez, J. C.

    2009-01-01

    A field experiment using trays was conducted at Ceuta's yachting harbour, North Africa, to study the effect in recolonization of placing trays with unpolluted defaunate sediments (fine and gross sands with low contents of organic matter) inside an enclosed yachting harbour characterized by high percentages of silt and clay and high concentrations of organic matter. Sediment recolonization in the trays was mainly undertaken by the species living naturally at the yachting harbour, which recolonized both uncontaminated gross and fine sand trays (such as the crustaceans Corophium runcicorne, Corophium sextonae and Nebalia bipes, the mollusc Parvicardium exiguum and the polychaete Pseudomalacoceros tridentata). However, other species like the polychaetes Cirriformia tentaculata and Platynereis dumerilii, although also abundant in the yachting harbour, were unable to colonize the trays through transport of larvae and/or adults in the water column. The recolonization was very quick, and after the first month, the values of abundance, species richness, diversity and evenness were similar in the experimental trays and in the reference area (yachting harbour). Although the multivariate analysis showed that the species composition differed between the trays and the reference area, there were no significant differences in recolonization of gross and fine sands, indicating that other factors different from the granulometry are modulating the recolonization patterns.

  2. Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1992-01-01

    To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.

  3. Effects of the humeral tray component positioning for onlay reverse shoulder arthroplasty design: a biomechanical analysis.

    PubMed

    Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David

    2015-04-01

    Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. R -process Element Cosmic Rays from Neutron Star Mergers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Komiya, Yutaka; Shigeyama, Toshikazu

    Neutron star mergers (NSMs) are one of the most plausible sources of r -process elements in the universe. Therefore, NSMs can also be a major source of ultra-heavy elements in cosmic rays. In this paper, we first estimate the contribution of r -process elements synthesized in NSMs to the ultra-heavy element cosmic rays (UHCRs) by calculating transport equations that take into account energy loss processes and spallations. We show that the flux of UHCRs accelerated by the NSMs themselves fluctuates by many orders of magnitude on a timescale of several million years and can overwhelm UHCRs accelerated by supernova remnantsmore » (SNRs) after an NSM takes place within a few kiloparsec from the solar system. Experiments with very long exposure times using meteorites as UHCR detectors can detect this fluctuation. As a consequence, we show that if NSMs are the primary source of UHCRs, future experiments using meteorites may be able to reveal the event history of NSMs in the solar vicinity. We also describe a possible difference in the abundance pattern and energy spectrum of UHCRs between NSM and SNR accelerations.« less

  5. Which Tibial Tray Design Achieves Maximum Coverage and Ideal Rotation: Anatomic, Symmetric, or Asymmetric? An MRI-based study.

    PubMed

    Stulberg, S David; Goyal, Nitin

    2015-10-01

    Two goals of tibial tray placement in TKA are to maximize coverage and establish proper rotation. Our purpose was to utilize MRI information obtained as part of PSI planning to determine the impact of tibial tray design on the relationship between coverage and rotation. MR images for 100 consecutive knees were uploaded into PSI software. Preoperative planning software was used to evaluate 3 different tray designs: anatomic, symmetric, and asymmetric. Approximately equally good coverage was achieved with all three trays. However, the anatomic compared to symmetric/asymmetric trays required less malrotation (0.3° vs 3.0/2.4°; P < 0.001), with a higher proportion of cases within 5° of neutral (97% vs 73/77%; P < 0.001). In this study, the anatomic tibia optimized the relationship between coverage and rotation. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Corn forage biological pretreatment by Trametes versicolor in a tray bioreactor.

    PubMed

    Planinić, Mirela; Zelić, Bruno; Čubel, Ivan; Bucić-Kojić, Ana; Tišma, Marina

    2016-08-01

    Trametes versicolor is a white-rot fungus known to be efficient in lignin removal due to its complex extracellular lignocellulolytic enzymatic system. Therefore, it can be used in the treatment of lignocellulose waste from agro, food, and wood industries. In a first experiment, corn forage treatment with T. versicolor was investigated in laboratory jars. In a second experiment, the process was scaled up to a tray bioreactor. In the tray bioreactor, the process of lignin degradation was improved, resulting in an increase in lignin conversion of up to 71% during seven days' treatment. © The Author(s) 2016.

  7. Sterility maintenance study: Dynamic evaluation of sterilized rigid containers and wrapped instrument trays to prevent bacterial ingress.

    PubMed

    Shaffer, Harry L; Harnish, Delbert A; McDonald, Michael; Vernon, Reid A; Heimbuch, Brian K

    2015-12-01

    Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria. Copyright © 2015. Published by Elsevier Inc.

  8. Efficacy of Home-use Bleaching Agents Delivered in Customized or Prefilled Disposable Trays: A Randomized Clinical Trial.

    PubMed

    Carlos, N R; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Basting, R T

    The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they

  9. Pressure dynamics in the trays caused by differences of the various impression materials and thickness of the relief in the maxillary edentulous model.

    PubMed

    Iwasaki, Masatoshi; Kawara, Misao; Inoue, Sayumi; Komiyama, Osamu; Iida, Takashi; Asano, Takashi

    2016-04-01

    The purpose of this study is to compare the pressure dynamics in the trays caused by differences in the various impression materials and in the thickness of the relief provided for the trays. In this study, two types of polyvinylsiloxane elastomers, one type of polyether elastomer and one type of alginate impression material were used. Pressure sensors were embedded at eight locations in a model of an edentulous maxilla, and used a simulation model covered with a pseudomucosa. For each impression material, the measurement was performed five times for each of the three types of trays, and the mean values were determined. Statistical analysis was carried out using one-way analysis of variance and the Tukey's HDS method, and the various pressure sensor values for each of the impression materials were compared 10s and 20s after the start of the measurement. Additionally, we compared differences among the three types of trays after 20s. The pressure values for sensors placed in the relief region tended to become uniform. Furthermore, we saw a tendency for the pressure to increase at the alveolar crests of the first molars on the left and right and at the posterior border of the palate, all of which support the denture, when relief was provided. The above results suggest that making the final impression for the denture using the selective pressure technique, with consideration given to the pressure dynamic, may lead to a good outcome in terms of preservation of the alveolar ridge. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. Robotic Vision, Tray-Picking System Design Using Multiple, Optical Matched Filters

    NASA Astrophysics Data System (ADS)

    Leib, Kenneth G.; Mendelsohn, Jay C.; Grieve, Philip G.

    1986-10-01

    The optical correlator is applied to a robotic vision, tray-picking problem. Complex matched filters (MFs) are designed to provide sufficient optical memory for accepting any orientation of the desired part, and a multiple holographic lens (MHL) is used to increase the memory for continuous coverage. It is shown that with appropriate thresholding a small part can be selected using optical matched filters. A number of criteria are presented for optimizing the vision system. Two of the part-filled trays that Mendelsohn used are considered in this paper which is the analog (optical) expansion of his paper. Our view in this paper is that of the optical correlator as a cueing device for subsequent, finer vision techniques.

  11. [The geometry of the keel determines the behaviour of the tibial tray against torsional forces in total knee replacement].

    PubMed

    García David, S; Cortijo Martínez, J A; Navarro Bermúdez, I; Maculé, F; Hinarejos, P; Puig-Verdié, L; Monllau, J C; Hernández Hermoso, J A

    2014-01-01

    The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  12. 105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT SOUTH END OF LANDLINE INSTRUMENTATION ROOM - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 75 FR 61521 - NUREG/CR-7010, Cable Heat Release, Ignition, and Spread in Tray Installations During Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ... tray configurations. The experiments conducted range from micro-scale, in which very small (5 mg... burned under a large oxygen- depletion calorimeter. Other experiments include cone calorimetry, smoke and... tray of cables underneath a bank of radiant panels. The results of the small-scale experiments are to...

  14. Training to Increase Safe Tray Carrying among Cocktail Servers

    ERIC Educational Resources Information Center

    Scherrer, Megan D.; Wilder, David A.

    2008-01-01

    We evaluated the effects of training on proper carrying techniques among 3 cocktail servers to increase safe tray carrying on the job and reduce participants' risk of developing musculoskeletal disorders. As participants delivered drinks to their tables, their finger, arm, and neck positions were observed and recorded. Each participant received…

  15. 29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ABOVE. THESE ARE NEWER APPARATUS AND NOT ORIGINAL. - Pacific Telephone & Telegraph Company Building, 1519 Franklin Street, Oakland, Alameda County, CA

  16. Comparative rice seed toxicity tests using filter paper, growth pouch-tm, and seed tray methods

    USGS Publications Warehouse

    Wang, W.

    1993-01-01

    Paper substrate, especially circular filter paper placed inside a Petri dish, has long been used for the plant seed toxicity test (PSTT). Although this method is simple and inexpensive, recent evidence indicates that it gives results that are significantly different from those obtained using a method that does not involve paper, especially when testing metal cations. The study compared PSTT using three methods: filter paper, Growth Pouch-TM, and seed tray. The Growth Pouch-TM is a commercially available device. The seed tray is a newly designed plastic receptacle placed inside a Petri dish. The results of the Growth Pouch-TM method showed no toxic effects on rice for Ag up to 40 mg L-1 and Cd up to 20 mg L-1. Using the seed tray method, IC50 (50% inhibitory effect concentration) values were 0.55 and 1.4 mg L-1 for Ag and Cd, respectively. Although results of filter paper and seed tray methods were nearly identical for NaF, Cr(VI), and phenol, the toxicities of cations Ag and Cd were reduced by using the filter paper method; IC50 values were 22 and 18 mg L-1, respectively. The results clearly indicate that paper substrate is not advisable for PSTT.

  17. 5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM SOUTH FACE OF LAUNCH OPERATIONS BUILDING. MICROWAVE DISH IN FOREGROUND. METEOROLOGICAL TOWER IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Fabrication of customized sectional impression trays in management of patients with limited mouth opening: a simple and unique approach.

    PubMed

    Krishna Ch, Vamsi; Mahendranadh Reddy, K; Gupta, Nidhi; Mahadev Shastry, Y; Chandra Sekhar, N; Aditya, Venkat; Reddy, G V K Mohan

    2013-01-01

    Impression making is not only important but is also the most significant step in the fabrication of any fixed or removable prosthesis. Proper impression making may be hindered by certain pathologic conditions. Reduced mouth opening is one of the common mechanical obstructions for proper orientation of the impression tray in the patient's mouth. In patients with trismus induced by submucous fibrosis, the procedure may be even more difficult to carry out because of reduced tissue resiliency and obliteration of vestibular spaces. Use of sectional trays offers one of the alternatives to overcome the problem of restricted mouth opening. Fabrication of customized impression trays according to the patient dentition improves the accuracy of impression making. The present case reports describe the fabrication of sectional custom trays designed for dentulous patients with chronic tobacco-induced submucous fibrosis.

  19. Tracer Transport Along a Vertical Fault Located in Welded Tuffs

    NASA Astrophysics Data System (ADS)

    Salve, R.; Liu, H.; Hu, Q.

    2002-12-01

    A near-vertical fault that intercepts the fractured welled tuff formation in the underground Exploratory Studies Facility (ESF) at Yucca Mountain, Nevada, has provided a unique opportunity to evaluate important hydrological parameters associated with faults (e.g., flow velocity, matrix diffusion, fault-fracture-matrix interactions). Alcove 8, which intersects the fault is located in the cross drift of the ESF, has been excavated for liquid releases through this fault and a network of fractures. Located 25 m below Alcove 8 in the main drift of the ESF, Niche 3 which also intercepts the fault, serves as the site for monitoring the wetting front and for collecting seepage following liquid releases in Alcove 8. To investigate the importance of matrix diffusion and the extent of area subject to fracture-matrix interactions, we released a mix of conservative tracers (pentafluorobenzoic acid [PFBA] and lithium bromide [LiBr]) along the fault. The ceiling of Niche 3 was blanketed with an array of trays to capture seepage, and seepage rates were continuously monitored by a water collection system connected to the trays. Additionally, a water sampling device, the passive-discreet water sampler (PDWS), was connected to three of the collections trays in Niche 3 into which water was seeping. The PDWS, designed to isolate continuous seepage from each tray into discreet samples for chemical analysis, remained connected to the trays over a period of three months. During this time, all water that seeped into the three trays was captured sequentially into sampling bottles and analyzed for concentrations of PFBA and LiBr. Water released along the fault initially traveled the 25 m vertical distance over a period of 36 days (at a velocity ~0.7 m/day). The seepage recovered in Niche 3 was less than 10% of the injected water with significant spatial and temporal fluctuations in seepage rates. Along a fast flow path, the benzoic tracer (PFBA) and LiBr were first detected ~12 days after

  20. 4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM NORTH FACE OF LAUNCH OPERATIONS BUILDING. TOPS OF BUNKER PERISCOPE AND FLAGPOLE ON ROOF OF LAUNCH OPERATIONS BUILDING IN BACKGROUND - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. 40. Coffee bean drying trays that are stored in racks ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. Coffee bean drying trays that are stored in racks under building and pulled out to sun dry beans on terraces to the north and south of building. HAER PR, 6-MAGU, 1C-3 - Hacienda Buena Vista, PR Route 10 (Ponce to Arecibo), Magueyes, Ponce Municipio, PR

  2. A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study

    PubMed Central

    Kulkarni, Rahul S.; Shah, Rupal J.; Chhajlani, Rahul; Saklecha, Bhuwan; Maru, Kavita

    2017-01-01

    Introduction The clinician’s skill, impression techniques, and materials play a very important role in recording fine details in an impression for accuracy of fixed partial denture prosthesis. Impression of prepared teeth and of the opposing arch can be recorded simultaneously by dual-arch trays, while the full arch metal trays are used for impressions of prepared teeth in one arch. Aim To measure and compare the accuracy of working dies made from impressions with metal and plastic dual arch trays and metal full arch trays, for two viscosities of impression material and by changing the sequence of pour of working and non-working sides. Materials and Methods A balanced design with independent samples was used to study the three variables (tray type, impression material viscosity, and pouring sequence). An impression made by dual arch trays and single arch trays were divided in to three groups (Group A-plastic dual arch tray, Group B-metal dual arch tray, Group C-full arch metal stock tray). Out of these three groups, two groups (Group A and B) were subdivided in to four subgroups each and one group (Group C) was subdivided in to two subgroups. A sample size of 30 was used in each subgroup yielding a total 300 impressions in three groups or ten subgroups. Impressions were made of a machined circular stainless steel die. All three dimensions (Occlusogingival, Mesiodistal, and Buccolingual) of the working dies as well as stainless steel standard die were measured three times, and the mean was used for the three standard sample values to which all working dies means were compared. Statistical analysis used for this study was a 3-factor analysis of variance with hypothesis testing at α =0.05. Results With respect to the selection of impression material viscosity statistically significant differences were found in the dies for the buccolingual and mesiodistal dimensions. Metal dual arch trays were slightly more accurate in the mesiodistal dimension in comparison to the

  3. Closeup of LDEF experiment trays documented during STS-32 photo survey

    NASA Image and Video Library

    1990-01-20

    Closeup of Long Duration Exposure Facility (LDEF) experiment trays is documented during STS-32 retrieval activity and photo survey conducted by crewmembers onboard Columbia, Orbiter Vehicle (OV) 102. Partially visible is the Polymer Matrix Composite Materials Experiment. In the background is the surface of the Earth.

  4. Columbia, OV-102, forward middeck locker experiments and meal tray assemblies

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Overall view of forward middeck locker shows Continuous Flow Electrophoresis System (CFES) experiment control and monitoring module and sample storage module (on port side) and Monodisperse Latex Reactor (MLR) (on starboard side). Water Dispenser Kit water gun (above CFES module) and meal tray assemblies covered with snack food packages and beverage containers appear around the two experiments. Thanks to a variety of juices and other food items, this array in the middeck probably represents the most colorful area onboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Most of the meal items have been carefully fastened to meal tray assemblies (foodtrays) and locker doors (or both). What has not been attached by conventional methods has been safely 'tucked' under something heavy (note jacket shoved into space occupied MLR). MLR is making its second flight and is designed to test the flexibility of making large-size, monodisperse (same size), polystyrene latex micro-spheres using

  5. Beta Vulgaris and Easter Egg Radish Growth in Varying Mediums and Locations

    NASA Astrophysics Data System (ADS)

    Brittingham, P.; Figueroa, A.

    2016-12-01

    The purpose of this experiment is to study the harvest yield and taste of Beta Vulgaris and Easter Egg Radish microgreens in different growing mediums and locations at the Stanford Farm. They are grown in three different mediums: compost, potting mix, and a 50/50 mix of both. We hypothesized that the even mixture of compost and potting mix would have a larger harvest yield and greater nutrient content while being grown in the lath house. The experiment begins with two sets of three planting trays, one in the greenhouse and one in the lath house, filled with the former growing mediums. Next, the seeds of the microgreens are sprinkled evenly in their designated halves of the tray, then covered with a thin layer of their growing medium to allow for germination. The trays in the lath house are watered 1-2 times a day while the greenhouse trays must be watered thrice. The progress of the microgreens are observed everyday and the weight, height, root length and width of the plant is measured. Once harvested, 9-11 days after planting, the microgreens are weighed and tested for taste and consistency. Because each microgreen variety is planted in only half of a tray, the weight of the full tray is calculated to estimate the value and yield of a single species on a larger scale. Upon collecting data from both the lath house and greenhouse, we found that the plants perform better in the 50/50 mixture and potting mix, but grow very poorly in the compost because it requires a lot of water and does not hold the moisture it receives. We also had a higher yield of Easter Egg Radish due to its height and water content. In the greenhouse, both species had a richer flavor. The farm plans to start a microgreen business to provide an added source of income and utilize the results of this experiment in an applied business model focused on efficiency and profit.

  6. Study on The Effectiveness of Egg Tray and Coir Fibre as A Sound Absorber

    NASA Astrophysics Data System (ADS)

    Kaamin, Masiri; Farah Atiqah Ahmad, Nor; Ngadiman, Norhayati; Kadir, Aslila Abdul; Razali, Siti Nooraiin Mohd; Mokhtar, Mardiha; Sahat, Suhaila

    2018-03-01

    Sound or noise pollution has become one major issues to the community especially those who lived in the urban areas. It does affect the activity of human life. This excessive noise is mainly caused by machines, traffic, motor vehicles and also any unwanted sounds that coming from outside and even from the inside of the building. Such as a loud music. Therefore, the installation of sound absorption panel is one way to reduce the noise pollution inside a building. The selected material must be a porous and hollow in order to absorb high frequency sound. This study was conducted to evaluate the potential of egg tray and coir fibre as a sound absorption panel. The coir fibre has a good coefficient value which make it suitable as a sound absorption material and can replace the traditional material; syntactic and wooden material. The combination of pyramid shape of egg tray can provide a large surface for uniform sound reflection. This study was conducted by using a panel with size 1 m x 1 m with a thickness of 6 mm. This panel consist of egg tray layer, coir fibre layer and a fabric as a wrapping for the aesthetic value. Room reverberation test has been carried to find the loss of reverberation time (RT). Result shows that, a reverberation time reading is on low frequency, which is 125 Hz to 1600 Hz. Within these frequencies, this panel can shorten the reverberation time of 5.63s to 3.60s. Hence, from this study, it can be concluded that the selected materials have the potential as a good sound absorption panel. The comparison is made with the previous research that used egg tray and kapok as a sound absorption panel.

  7. [Computer aided design and 3-dimensional printing for the production of custom trays of maxillary edentulous jaws based on 3-dimensional scan of primary impression].

    PubMed

    Chen, H; Zhao, T; Wang, Y; Sun, Y C

    2016-10-18

    To establish a digital method for production of custom trays for edentulous jaws using fused deposition modeling (FDM) based on three-dimensional (3D) scans of primary jaw impressions, and to quantitatively evaluate the accuracy. A red modeling compound was used to make a primary impression of a standard maxillary edentulous plaster model. The plaster model data and the primary impression tissue surface data were obtained using a 3D scanner. In the Gemomagic 2012 software, several commands were used, such as interactive drawing curves, partial filling holes, local offset, bodily offset, bodily shell, to imitate clinical procedures of drawing tray boundary, filling undercut, buffer, and generating the tray body. A standard shape of tray handle was designed and attached to the tray body and the data saved as stereolithography (STL) format. The data were imported into a computer system connected to a 3D FDM printing device, and the custom tray for the edentulous jaw model was printed layer upon layer at 0.2 mm/layer, using polylactic acid (PLA) filament, the tissue surface of the tray was then scanned with a 3D scanner. The registration functions of Geomagic 2012 was used to register the 3-dimentional surface data, and the point-cloud deviation analysis function of the Imageware 13.0 system was used to analyze the error. The CAD data of the custom tray was registered to the scan data, and the error between them was analyzed. The scanned plaster model surface was registered to the scanned impression surface and the scanned tray data to the CAD data, then the distance between the surface of plaster model and the scanned tissue surface of the custom tray was measured in Imageware 13.0. The deviation between the computer aided design data and the scanned data of the custom tray was (0.17±0.20) mm, with (0.19±0.18) mm in the primary stress-bearing area, (0.17±0.22) mm in the secondary stress-bearing area, (0.30±0.29) mm in the border seal area, (0.08±0.06) mm in the

  8. Normative data for distal line bisection and baking tray task.

    PubMed

    Facchin, Alessio; Beschin, Nicoletta; Pisano, Alessia; Reverberi, Cristina

    2016-09-01

    Line bisection is one of the tests used to diagnose unilateral spatial neglect (USN). Despite its wide application, no procedure or norms were available for the distal variant when the task was performed at distance with a laser pointer. Furthermore, the baking tray task was an ecological test aimed at diagnosing USN in a more natural context. The aim of this study was to collect normative values for these two tests in an Italian population. We recruited a sample of 191 healthy subjects with ages ranging from 20 to 89 years. They performed line bisection with a laser pointer on three different line lengths (1, 1.5, and 2 m) at a distance of 3 m. After this task, the subjects performed the baking tray task and a second repetition of line bisection to test the reliability of measurement. Multiple regression analysis revealed no significant effects of demographic variables on the performance of both tests. Normative cut-off values for the two tests were developed using non-parametric tolerance intervals. The results formed the basis for clinical use of these two tools for assessing lateralized performance of patients with brain injury and for diagnosing USN.

  9. Materials on the International Space Station Experiment (MISSE): Optical Analysis of Molecular Contamination on PEC1 Tray 2

    DTIC Science & Technology

    2007-02-20

    ellipsome- try and reflectometry were employed to show that the silicon wafers gained about a 420-A-thick layer of a silica-like con- taminant with BRDF...under Contract No. FA8802-04-C-0001. 111°. Contents I. Introduction .1 2. Ellipsometry and Reflectometry ... NASA ) I ;d~ ~ ---- ! Y Figure 2. MISSE I PECI Tray 2 facing away from Soyuz. (Courtesy NASA ) Among the samples mounted in PEC I Tray 2 were several

  10. Impingement of the Mobile Bearing on the Lateral Wall of the Tibial Tray in Unicompartmental Knee Arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Shirakawa, Nobuyuki; Tanaka, Sakae

    2016-07-01

    Tilting of the mobile bearing relative to the tibial tray in the flexion position may result from the implantation of femoral components more laterally relative to tibial components during unicompartmental knee arthroplasty (UKA) using the Oxford Knee. The purpose of the present study was to compare femoral component positions after UKA using the phase 3 device and a novel device. We further evaluated the placement of the femoral components with the new device in the flexion position to determine the association with short-term prognosis. The location of femoral and tibial components in the flexion position of 38 knees implanted using the phase 3 device and 49 knees using a novel device was assessed at 1 year postoperatively using radiography of the proximal tibia and distal femur in the flexion position. The femoral component was implanted more laterally using the new device than using the phase 3 device in the flexion position (P = .012), which caused the impingement of the mobile bearing against the lateral wall of the tibial tray. After UKA using the new device, 10% of patients exhibited the tilting phenomenon of the mobile bearing because of the lateral implantation of the femoral implant. To prevent implantation of the femoral component too laterally using the new device during UKA, knee surgeons should set the drill guide more medially such that the center of the drill is aligned with the middle of the medial femoral condyle. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Reliability and accuracy of real-time visualization techniques for measuring school cafeteria tray waste: validating the quarter-waste method.

    PubMed

    Hanks, Andrew S; Wansink, Brian; Just, David R

    2014-03-01

    Measuring food waste is essential to determine the impact of school interventions on what children eat. There are multiple methods used for measuring food waste, yet it is unclear which method is most appropriate in large-scale interventions with restricted resources. This study examines which of three visual tray waste measurement methods is most reliable, accurate, and cost-effective compared with the gold standard of individually weighing leftovers. School cafeteria researchers used the following three visual methods to capture tray waste in addition to actual food waste weights for 197 lunch trays: the quarter-waste method, the half-waste method, and the photograph method. Inter-rater and inter-method reliability were highest for on-site visual methods (0.90 for the quarter-waste method and 0.83 for the half-waste method) and lowest for the photograph method (0.48). This low reliability is partially due to the inability of photographs to determine whether packaged items (such as milk or yogurt) are empty or full. In sum, the quarter-waste method was the most appropriate for calculating accurate amounts of tray waste, and the photograph method might be appropriate if researchers only wish to detect significant differences in waste or consumption of selected, unpackaged food. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  12. Development of an integrated, unattended assay system for LWR-MOX fuel pellet trays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J.E.; Hatcher, C.R.; Pollat, L.L.

    1994-08-01

    Four identical unattended plutonium assay systems have been developed for use at the new light-water-reactor mixed oxide (LWR-MOX) fuel fabrication facility at Hanau, Germany. The systems provide quantitative plutonium verification for all MOX pellet trays entering or leaving a large, intermediate store. Pellet-tray transport and storage systems are highly automated. Data from the ``I-Point`` (information point) assay systems will be shared by the Euratom and International Atomic Energy Agency (IAEA) Inspectorates. The I-Point system integrates, for the first time, passive neutron coincidence counting (NCC) with electro-mechanical sensing (EMS) in unattended mode. Also, provisions have been made for adding high-resolution gammamore » spectroscopy. The system accumulates data for every tray entering or leaving the store between inspector visits. During an inspection, data are analyzed and compared with operator declarations for the previous inspection period, nominally one month. Specification of the I-point system resulted from a collaboration between the IAEA, Euratom, Siemens, and Los Alamos. Hardware was developed by Siemens and Los Alamos through a bilateral agreement between the German Federal Ministry of Research and Technology (BMFT) and the US DOE. Siemens also provided the EMS subsystem, including software. Through the USSupport Program to the IAEA, Los Alamos developed the NCC software (NCC COLLECT) and also the software for merging and reviewing the EMS and NCC data (MERGE/REVIEW). This paper describes the overall I-Point system, but emphasizes the NCC subsystem, along with the NCC COLLECT and MERGE/REVIEW codes. We also summarize comprehensive testing results that define the quality of assay performance.« less

  13. Vibration Analysis of the Space Shuttle External Tank Cable Tray Flight Data With and Without PAL Ramp

    NASA Technical Reports Server (NTRS)

    Walker, Bruce E.; Panda, Jayanta; Sutliff, Daniel L.

    2008-01-01

    External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first 2 min of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.

  14. Vibration Analysis of the Space Shuttle External Tank Cable Tray Flight Data with and without PAL Ramp

    NASA Technical Reports Server (NTRS)

    Walker, B. E.; Panda, B. E.; Sutliff, D. L.

    2008-01-01

    External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first two minutes of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.

  15. Spread potential of binucleate Rhizoctonia from propagation floors to trays containing stem cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucelate Rhizoctonia spp. (BNR), the cause of web blight, are present all year on container-grown azaleas in the southern U.S. BNR can be eliminated during vegetative propagation by submerging stem cuttings in 50°C water for 21 minutes. The objective was to evaluate risk of rooting trays bein...

  16. Implementing Adlerian Sand Tray Therapy with Adult Male Substance Abuse Offenders: A Phenomenological Inquiry

    ERIC Educational Resources Information Center

    Monakes, Sarah; Garza, Yvonne; Wiesner, Van, III; Watts, Richard E.

    2011-01-01

    The purpose of this phenomenological study was to understand the perceptions of adult male substance offenders who experienced sand tray therapy as an adjunct to their cognitive behavioral rehabilitative treatment. Results indicate a positive experience for participants. Implications for counselors are discussed. (Contains 1 table.)

  17. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures

    PubMed Central

    Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian

    2017-01-01

    Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875

  18. Computational study of the heat transfer of an avian egg in a tray.

    PubMed

    Eren Ozcan, S; Andriessens, S; Berckmans, D

    2010-04-01

    The development of an embryo in an avian egg depends largely on its temperature. The embryo temperature is affected by its environment and the heat produced by the egg. In this paper, eggshell temperature and the heat transfer characteristics from one egg in a tray toward its environment are studied by means of computational fluid dynamics (CFD). Computational fluid dynamics simulations have the advantage of providing extensive 3-dimensional information on velocity and eggshell temperature distribution around an egg that otherwise is not possible to obtain by experiments. However, CFD results need to be validated against experimental data. The objectives were (1) to find out whether CFD can successfully simulate eggshell temperature from one egg in a tray by comparing to previously conducted experiments, (2) to visualize air flow and air temperature distribution around the egg in a detailed way, and (3) to perform sensitivity analysis on several variables affecting heat transfer. To this end, a CFD model was validated using 2 sets of temperature measurements yielding an effective model. From these simulations, it can be concluded that CFD can effectively be used to analyze heat transfer characteristics and eggshell temperature distribution around an egg. In addition, air flow and temperature distribution around the egg are visualized. It has been observed that temperature differences up to 2.6 degrees C are possible at high heat production (285 mW) and horizontal low flow rates (0.5 m/s). Sensitivity analysis indicates that average eggshell temperature is mainly affected by the inlet air velocity and temperature, flow direction, and the metabolic heat of the embryo and less by the thermal conductivity and emissivity of the egg and thermal emissivity of the tray.

  19. Spacecraft materials studies on the Aerospace Corporation tray on EOIM-3

    NASA Technical Reports Server (NTRS)

    Stuckey, Wayne K.; Hemminger, Carol S.; Steckel, Gary L.; Hills, Malina M.; Hilton, Michael R.

    1995-01-01

    A passive tray was flown on the Effects of Oxygen Interaction with Materials experiment on STS-46 (EOIM-3) with 82 samples from The Aerospace Corporation. A variety of advanced materials related to potential uses on future spacecraft were included for evaluation representing optical coatings, lubricants, polymers, composites, carbon-carbon composite protective coatings, graphite protective coatings, thermal-control materials, and some samples of current materials. An overview of the available results from the investigations of these materials is presented.

  20. A novel open-tray impression technique for fabrication of a provisional prosthesis on immediate load implants in a completely edentulous arch.

    PubMed

    Kaneko, Takahiro; Yamagishi, Kiyoshi; Horie, Norio; Shimoyama, Tetsuo

    2013-01-01

    To evaluate the clinical outcome of a novel open-tray impression technique for fabrication of a provisional prosthesis supported by immediately loaded implants in a completely edentulous arch. An open-tray impression technique was evaluated in this retrospective study that included patients treated between March 2006 and October 2009. Preoperatively, a diagnostic prosthesis was delivered, and a novel open tray was fabricated based on this prosthesis. After implant placement, the impression and interocclusal record were taken simultaneously using the novel open tray. Laboratory-fabricated, screw-retained, all-acrylic resin provisional restorations were delivered on the same day of surgery. The prosthesis was assessed from the day of surgery until replacement with a definitive prosthesis. The study included 21 patients (mean age, 64.5 years) and a total of 125 implants. Of these, 104 implants were immediately loaded. In all patients, well-fitting provisional restorations supported by a minimum of four implants were delivered. Fracture of the first molar cusp was observed in one case after 30 days. However, there was no extensive fracture in the framework or functional disorder of the prosthesis. No implant failed during the follow-up after implant surgery. This protocol enabled fabrication of a well-fitting acrylic resin provisional prosthesis supported by immediately loaded implants because the impression was taken while in centric occlusion and an occlusion identical to the diagnostic prosthesis could be reconstructed.

  1. Potential of spreading binucleate Rhizoctonia from nursery propagation floors to trays containing azalea stem cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucleate Rhizoctonia fungi cause web blight on azaleas and other woody ornamental plants. This research focused on one aspect of how the pathogen may spread from contaminated floors of propagation houses into trays containing clean azalea stem cuttings that generate new root systems. Rhizoctonia w...

  2. Real-time, T-ray imaging using a sub-terahertz gyrotron

    NASA Astrophysics Data System (ADS)

    Han, Seong-Tae; Torrezan, Antonio C.; Sirigiri, Jagadishwar R.; Shapiro, Michael A.; Temkin, Richard J.

    2012-06-01

    We demonstrated real-time, active, T-ray imaging using a 0.46 THz gyrotron capable of producing 16 W in continuous wave operation and a pyroelectric array camera with 124-by-124 pixels. An expanded Gaussian beam from the gyrotron was used to maintain the power density above the detection level of the pyroelectric array over the area of the irradiated object. Real-time imaging at a video rate of 48 Hz was achieved through the use of the built-in chopper of the camera. Potential applications include fast scanning for security purposes and for quality control of dry or frozen foods.

  3. Tray service generates more food waste in dining areas of a continuing-care retirement community.

    PubMed

    Hackes, B L; Shanklin, C W; Kim, T; Su, A Y

    1997-08-01

    To determine if the type of service system affects the amount of service food waste (SFW) generated in dining areas of a continuing-care retirement community. A waste stream analysis was conducted for 7 days to determine quantity of SFW generated in three service systems: health care tray service, health care dining room with wait-staff service, and ambulatory dining room with family-style service. Weight and volume were determined. Health care tray service and wait-staff service were provided to 70 residents in a health care unit. Family-style service was provided as an optional service for 130 residents in independent-living units. An average of 229 meals were served per day. Analysis of variance and a multiple comparison method were used to compare mean weight and volume of SFW on a per meal, per day, and per week basis. During the 7-day period, 482.8 lb, or 83 gal, of SFW was disposed of Health care tray service generated more SFW by weight for all three meals than either family-style service or wait-staff service, and it generated the greatest total volume of service waste. Residents eating in the dining room with family-style service disposed of significantly less SFW by weight at lunch and dinner than those receiving the other two service styles. Changing the style of service can affect not only quantity of solid waste generated and associated disposal costs but also food and supply costs, meal acceptability, and quantity of natural resources required. The systems approach should be used to assess the feasibility of changing service system so that all costs are considered.

  4. Motion Law Analysis and Structural Optimization of the Ejection Device of Tray Seeder

    NASA Astrophysics Data System (ADS)

    Luo, Xin; Hu, Bin; Dong, Chunwang; Huang, Lili

    An ejection mechanism consisting four reset springs, an electromagnet and a seed disk was designed for tray seeder. The motion conditions of seeds in the seed disk were theoretical analyzed and intensity and height of seed ejection were calculated. The motions of the seeds and seed disk were multi-body dynamic simulated using Cosmos modules plug-in SolidWorks software package. The simulation results showed the consistence with the theoretical analysis.

  5. A case of gamasoidosis associated with exposure to a wild lorikeet feeding tray.

    PubMed

    Warren, Matthew; Tritton, Sara; Abbott, Nicola Cd; Sim, Sarah; Strutton, Geoffrey M; Soyer, H Peter

    2016-05-01

    Gamasoidosis (acariasis, avian-mite dermatitis or bird-mite dermatitis) is caused by members of the mite superfamily Dermanyssoidea. The mites lay their eggs on the nest of the birds they feed on. The also leave the nest and feed on humans if there is no bird host available. The bites result in urticated plaques and papules. Here we present a case of gamasoidosis from exposure to a wild lorikeet feeding tray. © 2015 The Australasian College of Dermatologists.

  6. Effect of variation of impression material combinations, dual arch tray types, and sequence of pour on the accuracy of working dies: "An in vitro study".

    PubMed

    Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar

    2016-01-01

    To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model.

  7. The Influence of Cement Morphology Parameters on the Strength of the Cement-Bone Interface in Tibial Tray Fixation.

    PubMed

    Nagel, Katrin; Bishop, Nicholas E; Schlegel, Ulf J; Püschel, Klaus; Morlock, Michael M

    2017-02-01

    The strength of the cement-bone interface in tibial component fixation depends on the morphology of the cement mantle. The purpose of this study was to identify thresholds of cement morphology parameters to maximize fixation strength using a minimum amount of cement. Twenty-three cadaveric tibiae were analyzed that had been implanted with tibial trays in previous studies and for which the pull-out strength of the tray had been measured. Specimens were separated into a group failing at the cement-bone interface (INTERFACE) and one failing in the bulk bone (BULK). Maximum pull-out strength corresponds to the ultimate strength of the bulk bone if the cement-bone interface is sufficiently strong. 3D models of the cement mantle in situ were reconstructed from computed tomography scans. The influences of bone mineral density and 6 cement morphology parameters (reflecting cement penetration, bone-cement interface, cement volume) on pull-out strength of the BULK group were determined using multiple regression analysis. The threshold of each parameter for classification of the specimens into either group was determined using receiver operating characteristic analysis. Cement penetration exceeding a mean of 1.1 mm or with a maximum of 5.6 mm exclusively categorized all BULK bone failure specimens. Failure strength of BULK failure specimens increased with bone mineral density (R 2  = 0.67, P < .001) but was independent of the cement morphology parameters. To maximize fixation strength, a mean cement penetration depth of at least 1.1 mm should be achieved during tibial tray cementing. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Sound absorption study on acoustic panel from kapok fiber and egg tray

    NASA Astrophysics Data System (ADS)

    Kaamin, Masiri; Mahir, Nurul Syazwani Mohd; Kadir, Aslila Abd; Hamid, Nor Baizura; Mokhtar, Mardiha; Ngadiman, Norhayati

    2017-12-01

    Noise also known as a sound, especially one that is loud or unpleasant or that causes disruption. The level of noise can be reduced by using sound absorption panel. Currently, the market produces sound absorption panel, which use synthetic fibers that can cause harmful effects to the health of consumers. An awareness of using natural fibers from natural materials gets attention of some parties to use it as a sound absorbing material. Therefore, this study was conducted to investigate the potential of sound absorption panel using egg trays and kapok fibers. The test involved in this study was impedance tube test which aims to get sound absorption coefficient (SAC). The results showed that there was good sound absorption at low frequency from 0 Hz up to 900 Hz where the maximum absorption coefficient was 0.950 while the maximum absorption at high frequencies was 0.799. Through the noise reduction coefficient (NRC), the material produced NRC of 0.57 indicates that the materials are very absorbing. In addition, the reverberation room test was carried out to get the value of reverberation time (RT) in unit seconds. Overall this panel showed good results at low frequencies between 0 Hz up to 1500 Hz. In that range of frequency, the maximum reverberation time for the panel was 3.784 seconds compared to the maximum reverberation time for an empty room was 5.798 seconds. This study indicated that kapok fiber and egg tray as the material of absorption panel has a potential as environmental and cheap products in absorbing sound at low frequency.

  9. The Case of the Unreturned Cafeteria Trays: An Investigation Based upon Theories of Motivation and Human Behavior.

    ERIC Educational Resources Information Center

    Etheredge, Lloyd S.

    This student manual is intended to help undergraduate political science students analyze human behavior. The manual poses the problem of why a group of high school students failed to take their cafeteria trays to the dirty dish room. It presents alternative solutions which students discuss as they explore various interpretations of human…

  10. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data

    PubMed Central

    Haldimann, M.; Alt, A.; Blanc, A.; Brunner, K.; Sager, F.; Dudler, V.

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (Ea) of 188 ± 36 kJ mol−1 and the pre-exponential factor (D0) of 3.6 × 1014 cm2s−1 were determined for diffusing Sb species. Ea was similar to previously reported values for PET bottles obtained with a different experimental approach. Ea and D0 were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data. PMID:23286325

  11. Migration of antimony from PET trays into food simulant and food: determination of Arrhenius parameters and comparison of predicted and measured migration data.

    PubMed

    Haldimann, M; Alt, A; Blanc, A; Brunner, K; Sager, F; Dudler, V

    2013-01-01

    Migration experiments with small sheets cut out from ovenable PET trays were performed in two-sided contact with 3% acetic acid as food simulant at various temperatures. The fraction of diffusible antimony (Sb) was estimated to be 62% in the PET sample under study. Apparent diffusion coefficients of Sb in PET trays were determined experimentally. Measurement of migration between 20 and 150°C yielded a linear Arrhenius plot over a wide temperature range from which the activation energy (E(a)) of 188 ± 36 kJ mol(-1) and the pre-exponential factor (D(0)) of 3.6 × 10(14) cm(2) s(-1) were determined for diffusing Sb species. E (a) was similar to previously reported values for PET bottles obtained with a different experimental approach. E (a) and D (0) were applied as model parameters in migration modelling software for predicting the Sb transfer in real food. Ready meals intended for preparation in a baking oven were heated in the PET trays under study and the actual Sb migration into the food phase was measured by isotope dilution ICP-MS. It was shown that the predictive modelling reproduces correctly experimental data.

  12. An applicable method for efficiency estimation of operating tray distillation columns and its comparison with the methods utilized in HYSYS and Aspen Plus

    NASA Astrophysics Data System (ADS)

    Sadeghifar, Hamidreza

    2015-10-01

    Developing general methods that rely on column data for the efficiency estimation of operating (existing) distillation columns has been overlooked in the literature. Most of the available methods are based on empirical mass transfer and hydraulic relations correlated to laboratory data. Therefore, these methods may not be sufficiently accurate when applied to industrial columns. In this paper, an applicable and accurate method was developed for the efficiency estimation of distillation columns filled with trays. This method can calculate efficiency as well as mass and heat transfer coefficients without using any empirical mass transfer or hydraulic correlations and without the need to estimate operational or hydraulic parameters of the column. E.g., the method does not need to estimate tray interfacial area, which can be its most important advantage over all the available methods. The method can be used for the efficiency prediction of any trays in distillation columns. For the efficiency calculation, the method employs the column data and uses the true rates of the mass and heat transfers occurring inside the operating column. It is highly emphasized that estimating efficiency of an operating column has to be distinguished from that of a column being designed.

  13. Exposure to antimony from polyethylene terephthalate (PET) trays used in ready-to-eat meals.

    PubMed

    Haldimann, M; Blanc, A; Dudler, V

    2007-08-01

    Antimony residues, a result of the use of a polycondensation catalyst in the production of polyethylene terephthalate (PET) oven-proof trays, were analysed in ready-to-eat meals. The toxicity of antimony has raised concerns about consumer safety; therefore, the migration of small fractions of these residues into ready meals and foods as a result of cooking directly in the PET trays was studied. A straightforward approach of measuring real samples was selected to obtain accurate exposure data. Background antimony concentration was determined separately from a series of lunch meals, which ranged from not detectable to 3.4 microg kg(-1). Microwave and conventional oven-cooking caused a distinct increase in the concentration of antimony in food and ready meals of 0-17 and 8-38 microg kg(-1), respectively, depending, to a certain extent, on the industrial preparations. The migrated quantities of antimony corresponded to 3-13 microg. For comparison, PET roasting bags and ready-made dough products in PET baking dishes were also evaluated. About half of the products prepared at a temperature of 180 degrees C exceeded the specific migration limit set for food contact material by the European Commission. However, the migrated amounts of antimony relative to the accepted tolerable daily intake (TDI) show that exposure from this type of food is currently not of toxicological concern.

  14. Clinical study of the safety and effectiveness of a novel over-the-counter bleaching tray system

    PubMed Central

    Ghalili, K Michael; Khawaled, Kamal; Rozen, Doran; Afsahi, Veda

    2014-01-01

    We investigated color change, gingival irritation, and tooth sensitivity in patients undergoing at-home vital tooth bleaching with a novel over-the-counter bleaching tray system. Tooth color shade in anterior teeth, supragingival plaque and gingivitis in Ramfjord teeth, as well as visual assessment of teeth gingival tissues and mucosa were evaluated in-office prior to treatment, after two consecutive applications of the 9% hydrogen peroxide bleaching product, after eight applications (10 minutes/day for 3 days at home), and after ten applications (50 minutes exposure over 5 days). Color stability was evaluated at 3 months after completing the treatment regimen. Over-the-counter bleaching products can be used by the patient at home without dentist supervision, but are frequently associated with gingival irritation and tooth sensitivity despite low concentrations of peroxide agents. Our investigations showed that the treatment is tolerable and safe with a low incidence of adverse effects. Any adverse effects associated with use of the whitening gel and tray are temporary, easily controlled, and often disappear within minutes of treatment. Statistical analysis revealed significant improvement in teeth whitening following treatment (mean color change of seven shades) and at three months after treatment. PMID:24591847

  15. Effect of variation of impression material combinations, dual arch tray types, and sequence of pour on the accuracy of working dies: “An in vitro study”

    PubMed Central

    Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar

    2016-01-01

    Aims: To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. Subjects and Methods: The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Statistical Analysis Used: Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. Results: The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. Conclusions: From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model. PMID:27141172

  16. In-service testing of Ni{sub 3}Al coupons and trays in carburizing furnaces at Delphi Saginaw. CRADA final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sikka, V.K.; Santella, M.L.; Viswanathan, S.

    1998-08-01

    This Cooperative Research and Development Agreement (CRADA) report deals with the development of nickel aluminide alloy for improved longer life heat-resistant fixture assemblies for batch and continuous pusher carburizing furnaces. The nickel aluminide development was compared in both coupon and component testing with the currently used Fe-Ni-Cr heat-resisting alloy known as HU. The specific goals of the CRADA were: (1) casting process development, (2) characterization and possible modification of the alloy composition to optimize its manufacturing ability and performance under typical furnace operating conditions, and (3) testing and evaluation of specimens and prototype fixtures. In support of the CRADA objectives,more » coupons of nickel aluminide and the HU alloy were installed in both batch and pusher furnaces. The coupons were taken from two silicon levels and contained welds made with two different filler compositions (IC-221LA and IC-221W). Both nickel-aluminide and HU coupons were removed from the batch and pusher carburizing furnace at time intervals ranging from one month to one year. The exposed coupons were cut and mounted for metallographic, hardness, and microprobe analysis. The results of the microstructural analysis have been transmitted to General Motors Corporation, Saginaw Division (Delphi Saginaw) through reports that were presented at periodic CRADA review meetings. Based on coupon testing and verification of the coupon results with the testing of trays, Delphi Saginaw moved forward with the use of six additional trays in a batch furnace and two assemblies in a pusher furnace. Fifty percent of the trays and fixtures are in the as-cast condition and the remaining trays and fixtures are in the preoxidized condition. The successful operating experience of two assemblies in the pusher furnace for nearly a year formed the basis for a production run of 63 more assemblies. The production run required melting of 94 heats weighing 500 lb. each

  17. Spread potential of binucleate Rhizoctonia from nursery propagation floors to trays containing azalea stem cuttings and sanitary control options

    USDA-ARS?s Scientific Manuscript database

    Binucelate Rhizoctonia sp. (BNR), the cause of web blight, can be spread on azalea stem cuttings into propagation houses, but can be eliminated from stems by submerging cuttings in 50°C water for 21 minutes. The overall objective was to evaluate risk of rooting cuttings in trays becoming contaminate...

  18. Automated reading of MIC microdilution trays containing fluorogenic enzyme substrates with the Sensititre Autoreader.

    PubMed Central

    Staneck, J L; Allen, S D; Harris, E E; Tilton, R C

    1985-01-01

    The Sensititre Autoreader is a microcomputer-driven instrument capable of automatically reading antimicrobial susceptibility microdilution trays. The instrument measures the fluorescence liberated by bacterial enzymatic activity on fluorogenic substrates as an indicator of growth in each well. A mathematical algorithm converts the fluorescent signals from an antimicrobial dilution series to an MIC endpoint. A three-center study evaluated the performance of the Autoreader in comparison with MIC determined visually in a duplicate set of control plates lacking fluorogenic substrate. Among 828 isolates of gram-negative bacilli tested against 17 antimicrobial agents, Autoreader 18-h MIC were within +/- 1 twofold dilution of control MIC values (agreement) in 95.3% of instances. In 3.5% of the instances, Autoreader values occurred +/- 2 half-step dilutions from control values (minor discrepancy), and in only 1.2% of instances did Autoreader values deviate from control values by greater than +/- 2 dilution steps (major discrepancy). Agreement, minor discrepancies, and major discrepancies were noted among 148 gram-positive cocci tested against 11 antimicrobial agents in 93.5, 4.8, and 1.7% of the instances, respectively. Over half of the major discrepancies noted with gram-negative bacilli occurred with Proteus mirabilis-beta-lactam combinations, a problem that was resolved when a lower initial inoculum was used. Inter-and intralaboratory reproducibility was excellent. Standard Sensititre susceptibility trays may be instrument read at 18 h reproducibly and accurately with only slight modification of conventional procedures to include fluorogenic enzyme substrates in the incubation broth. PMID:4031033

  19. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study.

    PubMed

    Chopra, Sakshi; Gupta, Narendra Kumar; Tandan, Amrit; Dwivedi, Ravi; Gupta, Swati; Agarwal, Garima

    2016-01-01

    Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. A significant difference in the pressure produced using different impression materials was found (P < 0.001). Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  20. Effect of tray-based and trayless tooth whitening systems on microhardness of enamel surface and subsurface.

    PubMed

    Teixeira, Erica C N; Ritter, André V; Thompson, Jeffrey Y; Leonard, Ralph H; Swift, Edward J

    2004-12-01

    To evaluate the effect of tray-based and trayless tooth whitening systems on surface and subsurface microhardness of human enamel. Enamel slabs were obtained from recently extracted human third molars. Specimens were randomly assigned to six groups according to tooth whitening treatment (n = 10): 6.0% hydrogen peroxide (HP) (Crest Whitestrips), 6.5% HP (Crest Professional Whitestrips), 7.5% HP (Day White Excel 3), 9.5% HP (Day White Excel 3), 10% carbamide peroxide (Opalescence), and a control group (untreated). Specimens were treated for 14 days following manufacturers' recommended protocols, and were immersed in artificial saliva between treatments. Enamel surface Knoop microhardness (KHN) was measured immediately before treatment, and at days 1, 7, and 14 of treatment. After treatment, subsurface microhardness was measured at depths of 50-500 microm. Data were analyzed for statistical significance using analysis of variance. Differences in microhardness for treated vs. untreated enamel surface were not statistically significant at any time interval. For 6.5% and 9.5% HP, there was a decrease in surface microhardness values during treatment, but at the end of treatment the microhardness values were not statistically different from the baseline values. For the enamel subsurface values, no differences were observed between treated vs. untreated specimens at each depth. Trayless and tray-based tooth whitening treatments do not significantly affect surface or subsurface enamel microhardness.

  1. Effects of Impression Material, Impression Tray Type, and Type of Partial Edentulism on the Fit of Cobalt-Chromium Partial Denture Frameworks on Initial Clinical Insertion: A Retrospective Clinical Evaluation.

    PubMed

    Baig, Mirza Rustum; Akbar, Jaber Hussain; Qudeimat, Muawia; Omar, Ridwaan

    2018-02-15

    To evaluate the effects of impression material, impression tray type, and type of partial edentulism (ie, Kennedy class) on the accuracy of fit of cobalt-chromium (Co-Cr) partial removable dental prostheses (PRDP) in terms of the number of fabricated frameworks required until the attainment of adequate fit. Electronic case documentations of 120 partially edentulous patients provided with Co-Cr PRDP treatment for one or both arches were examined. Statistical analyses of data were performed using analysis of variance and Tukey honest significant difference test to compare the relationships between the different factors and the number of frameworks that needed to be fabricated for each patient (α = .05). Statistical analysis of data derived from 143 records (69 maxillary and 74 mandibular) revealed no significant correlation between impression material, tray type, or Kennedy class and the number of construction attempts for the pooled or individual arch data (P ≥ .05). In PRDP treatment, alginate can be chosen as a first-choice material, and metal stock trays can be a preferred option for making final impressions to fabricate Co-Cr frameworks.

  2. Self-Control Assessments of Capuchin Monkeys With the Rotating Tray Task and the Accumulation Task

    PubMed Central

    Beran, Michael J.; Perdue, Bonnie M.; Rossettie, Mattea S.; James, Brielle T.; Whitham, Will; Walker, Bradlyn; Futch, Sara E.; Parrish, Audrey E.

    2016-01-01

    Recent studies of delay of gratification in capuchin monkeys using a rotating tray (RT) task have shown improved self-control performance in these animals in comparison to the accumulation (AC) task. In this study, we investigated whether this improvement resulted from the difference in methods between the rotating tray task and previous tests, or whether it was the result of greater overall experience with delay of gratification tasks. Experiment 1 produced similar performance levels by capuchins monkeys in the RT and AC tasks when identical reward and temporal parameters were used. Experiment 2 demonstrated a similar result using reward amounts that were more similar to previous AC experiments with these monkeys. In Experiment 3, monkeys performed multiple versions of the AC task with varied reward and temporal parameters. Their self-control behavior was found to be dependent on the overall delay to reward consumption, rather than the overall reward amount ultimately consumed. These findings indicate that these capuchin monkeys’ self-control capacities were more likely to have improved across studies because of the greater experience they had with delay of gratification tasks. Experiment 4 and Experiment 5 tested new, task-naïve monkeys on both tasks, finding more limited evidence of self-control, and no evidence that one task was more beneficial than the other in promoting self-control. The results of this study suggest that future testing of this kind should focus on temporal parameters and reward magnitude parameters to establish accurate measures of delay of gratification capacity and development in this species and perhaps others. PMID:27298233

  3. Analysis of impactor residues in tray clamps from the Long Duration Exposure Facility. Part 2: Clamps from Bay B of the satellite

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Zolensky, Michael E.

    1994-01-01

    The Long Duration Exposure Facility (LDEF) was placed in low-Earth orbit (LEO) in 1984 and recovered 5.7 years later. The LDEF was host to several individual experiments specifically designed to characterize critical aspects of meteoroid and debris environment in LEO. However, it was realized from the beginning that the most efficient use of the satellite would be to examine the entire surface for impact features. In this regard, particular interest centered on common exposed materials that faced in all LDEF pointing directions. Among the most important of these materials was the tray clamps. Therefore, in an effort to better understand the nature of particulates in LEO and their effects on spacecraft hardware, residues found in impact features on LDEF tray clamp surfaces are being analyzed. This catalog presents all data from clamps from Bay B of the LDEF. NASA Technical Memorandum 104759 has cataloged impacts that occurred on Bay B (published March 1993). Subsequent catalogs will include clamps from succeeding bays of the satellite.

  4. United States Navy - Canadian forces solid state flight data recorder/crash position locator experiment on the B-720 controlled impact demonstration

    NASA Technical Reports Server (NTRS)

    Watters, D. M.

    1986-01-01

    The operation of a radio beacon position locator during and after the remotely controlled transport aircraft is discussed. The radio beacon transmission was actuated and was picked up by the Navy P-3A chase aircraft for a short time, after which reception was lost. The pilot reported that he received a signal on both 121.5 MHz and 243 MHz for a period of approximately 5 seconds. Five minutes after the crash a portable direction finding unit located on the roof of the NASA Dryden Flight Research Facility, 4 miles distant from the crash, was unable to pick up the beacon transmission. The fire crews started fighting the fires approximately 90 seconds after the time of impact. Navy personnel access to the crash site was allowed on the morning of December 2, 1984. Radio beacon locator was found resting top side up, 15 feet forward and 13 feet perpendicular from the tray location the starboard side of the aircraft. An immediate inspection indicated the airfoil suffered moderate fire damage with paint peeling but not intumescing. The visual marker strobe lamp housings were intact but extensively burned such that it was impossible to see if the lamps had survived. The airfoil suffered minor structural damage, with assorted dents, etc. The extended plunger on the ARU-21 release unit indicated that the pyrotechnic deployment system operated. The radio beacon base (tray) suffered some heat and fire damage, and was charred and blackened by smoke. The frangible switch in the nose survived and the switch in the belly was recovered and found to have actuated. It is assumed that this switch fired the ARU-21 squib. There were no other release switches installed in the normally open system in the aircraft.

  5. Self-control assessments of capuchin monkeys with the rotating tray task and the accumulation task.

    PubMed

    Beran, Michael J; Perdue, Bonnie M; Rossettie, Mattea S; James, Brielle T; Whitham, Will; Walker, Bradlyn; Futch, Sara E; Parrish, Audrey E

    2016-08-01

    Recent studies of delay of gratification in capuchin monkeys using a rotating tray (RT) task have shown improved self-control performance in these animals in comparison to the accumulation (AC) task. In this study, we investigated whether this improvement resulted from the difference in methods between the rotating tray task and previous tests, or whether it was the result of greater overall experience with delay of gratification tasks. Experiment 1 produced similar performance levels by capuchins monkeys in the RT and AC tasks when identical reward and temporal parameters were used. Experiment 2 demonstrated a similar result using reward amounts that were more similar to previous AC experiments with these monkeys. In Experiment 3, monkeys performed multiple versions of the AC task with varied reward and temporal parameters. Their self-control behavior was found to be dependent on the overall delay to reward consumption, rather than the overall reward amount ultimately consumed. These findings indicate that these capuchin monkeys' self-control capacities were more likely to have improved across studies because of the greater experience they had with delay of gratification tasks. Experiment 4 and Experiment 5 tested new, task-naïve monkeys on both tasks, finding more limited evidence of self-control, and no evidence that one task was more beneficial than the other in promoting self-control. The results of this study suggest that future testing of this kind should focus on temporal parameters and reward magnitude parameters to establish accurate measures of delay of gratification capacity and development in this species and perhaps others. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Making an implant-level impression using solid plastic, press-fit, closed-tray impression copings: a clinical report.

    PubMed

    Selecman, Audrey M; Wicks, Russell A

    2009-03-01

    An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration, especially when 2 or more implants have been placed. However, convergent implants placed too close in proximity pose several problems, starting with the impression. In situations of extreme convergence or close proximity, modification of conventional metal copings may be impossible. This clinical report describes the use and associated advantages and disadvantages of solid plastic, press-fit, closed-tray impression copings as a mechanism suitable to create an implant-level cast.

  7. Predicted and observed directional dependence of meteoroid/debris impacts on LDEF thermal blankets

    NASA Technical Reports Server (NTRS)

    Drolshagen, Gerhard

    1993-01-01

    The number of impacts from meteoroids and space debris particles to the various LDEF rows is calculated using ESABASE/DEBRIS, a 3-D numerical analysis tool. It is based on recent reference environment flux models and includes geometrical and directional effects. A comparison of model predictions and actual observations is made for penetrations of the thermal blankets which covered the UHCR experiment. The thermal blankets were located on all LDEF rows, except 3, 9, and 12. Because of their uniform composition and thickness, these blankets allow a direct analysis of the directional dependence of impacts and provide a test case for the latest meteoroid and debris flux models.

  8. Interim Status Closure Plan Open Burning Treatment Unit Technical Area 16-399 Burn Tray

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vigil-Holterman, Luciana R.

    2012-05-07

    This closure plan describes the activities necessary to close one of the interim status hazardous waste open burning treatment units at Technical Area (TA) 16 at the Los Alamos National Laboratory (LANL or the Facility), hereinafter referred to as the 'TA-16-399 Burn Tray' or 'the unit'. The information provided in this closure plan addresses the closure requirements specified in the Code of Federal Regulations (CFR), Title 40, Part 265, Subparts G and P for the thermal treatment units operated at the Facility under the Resource Conservation and Recovery Act (RCRA) and the New Mexico Hazardous Waste Act. Closure of themore » open burning treatment unit will be completed in accordance with Section 4.1 of this closure plan.« less

  9. Sanitation Can Be A Foundation Disease Management Tool: Potential Of Spreading Binucleate Rhizoctonia from Nursery Propagation Floors To Trays Containing Azalea Stem Cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucelate Rhizoctonia spp. (BNR), the cause of web blight, are present all year on container-grown azaleas in the southern U.S. BNR can be eliminated during vegetative propagation by submerging stem cuttings in 50°C water for 21 minutes. The objective was to evaluate risk of rooting trays being con...

  10. Columbia, OV-102, forward middeck locker experiments and meal tray assemblies

    NASA Image and Video Library

    1982-07-04

    STS004-28-330 (27 June-4 July 1982) --- Thanks to a variety of juices and other food items, this array in the middeck area probably represents the most colorful area onboard the Earth-orbiting space shuttle Columbia. Most of the meal items have been carefully fastened to food trays and locker doors (or both). What has not been attached by conventional methods has been safely ?tucked? under something heavy (note jacket shoved into space occupied by one of Columbia?s experiments). The Monodisperse Latex Reflector (MLR), making its second flight on Columbia, is designed to test the feasibility of making large-size, monodisperse (same size), and polystyrene latex micro-spheres using the products of the STS-3 mission as seed particles. The latex spheres are used in calibration of scientific and industrial equipment and have potential medical and research applications. This frame was exposed with a 35mm camera. Onboard the space vehicle for seven days were astronauts Thomas K. Mattingly II and Henry W. Hartsfield Jr. Photo credit: NASA

  11. An Evaluation of Foods Processed in Tray Pack versus Two Standard Food Service Containers. Part 1. Sensory, Container and Bacteriological Tests

    DTIC Science & Technology

    1986-02-01

    precooked frozen packed foods; (2) shelf life of Tray Pack vs. the no. 10 can at ambient and stressful storage temperatures; (3) changes in nutrient...bacteriological tests to certify safety for human consumption. Both Natick RD&E Center and Kraft products were subjected to 9 I...heat processed products that were storage temperature stressed at 380 C, QS data indicated that expected storage life of seven of the CC products was

  12. The Impact of Location and Growing Medium on Harvest Yield and Flavor of Basil and Squash Microgreens

    NASA Astrophysics Data System (ADS)

    Leal, J.; Ventura, C. J.

    2016-12-01

    The purpose of this experiment is to discover the most efficient, feasible way to produce a high yield of flavorful microgreens within the best growing medium and building location at the Stanford Educational Farm. In recent years, microgreens, young, small edible greens utilized as flavor garnishes for fine dining, have evolved into an immensely profitable market that will continue to expand and prosper. To capitalize on such opportunities, the primary metrics focused upon are harvest yield and flavor of basil and squash microgreens, as they develop in different concentrations of quick root and compost while located in either a greenhouse or lath house. It was hypothesized that if basil and squash microgreens were grown in a mixture of 50% compost and 50% quick root in the greenhouse, then they would produce the greatest harvest yield and maximum amount of flavor. The general experimental protocol includes monitoring the growth of the microgreens, then harvesting directly after the first true leaves begin to emerge. Upon harvest, each set of microgreens are separated into different clear glass jars to place on a small scale for weighing to determine the yield and tasting the leaves to analyze the flavor content. The highest yield of basil (63 grams) developed in a tray of 100% quick root in the lath house, while the greatest yield of squash (51 grams) succeeded in 100% quick root in the greenhouse. Overall however, the basil grew fastest in the greenhouse but tasted stronger in the lath house. Additionally, because the harvest yield and flavor results were so poor in all other locations and growing mediums for squash during the first trial, it cannot be considered a viable microgreen. In the future, more trials should be conducted for greater numbers of trays of microgreens to collect more data. The nutritional value of microgreens should also be explored further to obtain a holistic approach to the value of these plants from seed to harvest to consumption.

  13. Lap-tray and triangular sling are no more effective than a hemi-sling in preventing shoulder subluxation in those at risk early after stroke: a randomized trial.

    PubMed

    Ada, Louise; Foongchomcheay, Anchalee; Langhammer, Birgitta; Preston, Elisabeth; Stanton, Rosalyn; Robinson, John; Paul, Serene; Canning, Colleen

    2017-02-01

    Shoulder subluxation is a common secondary impairment of the upper limb following stroke. A range of supportive devices are used in rehabilitation to prevent shoulder subluxation, including hemi-slings and firm supports, such as arm troughs, however, there is little evidence regarding their efficacy. To determine whether a modified lap-tray during sitting and a triangular sling during standing is more effective than a hemi-sling in preventing shoulder subluxation, pain, contracture and upper limb activity limitation after stroke. A prospective, randomized trial with concealed allocation, assessor blinding and intention-to-treat analysis. Three inpatient rehabilitation units in Australia and Norway. Forty-six acute stroke survivors within 3 weeks of stroke who were at risk of subluxation. The experimental group used a modified lap-tray while sitting and a triangular sling while standing to support the affected arm for four weeks. The control group used a hemi-sling while sitting and standing. The primary outcome was amount of shoulder subluxation on X-ray. Secondary outcomes were upper limb activity, pain and contracture. There was no significant difference between groups in terms of shoulder subluxation (MD -3 mm, 95% CI -8 to 3). There was a trend for the experimental group to develop less pain at rest (MD -0.7 out of 10, 95% CI -2.2 to 0.8) and during shoulder external rotation (MD -1.7 out of 10, 95% CI -3.7 to 0.3) and a trend towards having less contracture of shoulder external rotation (MD -10 deg, 95% CI -22 to 2). There was no significant difference between groups in terms of other contractures and activity of the upper limb. A lap-tray during sitting combined with a triangular sling during standing is no more effective than a hemi-sling in preventing subluxation, pain, contracture and activity limitation in acute stroke survivors at risk of shoulder subluxation. The use of a lap-tray during sitting and triangular sling during standing is not indicated as

  14. Dimensional accuracy of pickup implant impression: an in vitro comparison of novel modular versus standard custom trays.

    PubMed

    Simeone, Piero; Valentini, Pier Paolo; Pizzoferrato, Roberto; Scudieri, Folco

    2011-01-01

    The purpose of this in vitro study was to compare the dimensional accuracy of the pickup impression technique using a modular individual tray (MIT) and using a standard individual tray (ST) for multiple internal-connection implants. The roles of both materials and geometric misfits were considered. First, because the MIT relies on the stiffness and elasticity of acrylic resin material, a preliminary investigation of the resin volume contraction during curing and polymerization was done. Then, two sets of specimens were tested to compare the accuracy of the MIT (test group) to that of the ST (control group). The linear and angular displacements of the transfer copings were measured and compared during three different stages of the impression procedure. Experimental measurements were performed with a computerized coordinate measuring machine. The curing dynamic of the acrylic resin was strongly dependent on the physical properties of the acrylic material and the powder/liquid ratio. Specifically, an increase in the powder/liquid ratio accelerated resin polymerization (curing time decreases by 70%) and reduced the final volume contraction by 45%. However, the total shrinkage never exceeded the elastic limits of the material; hence, it did not affect the coping's stability. In the test group, linear errors were reduced by 55% and angular errors were reduced by 65%. Linear and angular displacements of the transfer copings were significantly reduced with the MIT technique, which led to higher dimensional accuracy versus the ST group. The MIT approach, in combination with a thin and uniform amount of acrylic resin in the pickup impression technique, showed no significant permanent distortions in multiple misalignment internal-connection implants compared to the ST technique.

  15. Retention strength of impression materials to a tray material using different adhesive methods: an in vitro study.

    PubMed

    Marafie, Yousef; Looney, Stephen; Nelson, Steven; Chan, Daniel; Browning, William; Rueggeberg, Frederick

    2008-12-01

    A new self-stick adhesive system has been purported to eliminate the need to use chemical adhesives with plastic impression trays; however, no testing has confirmed the claim. The purpose of this study was to compare the in vitro retentive strength of impression materials to plastic substrates having conventional adhesive (CA) or the self-stick adhesive system, with and without mechanical retention. Three types of impression materials (irreversible hydrocolloid (IH), vinyl polysiloxane (VPS), and polyether (PE)) were applied to polystyrene disc-shaped surfaces (33.68 cm(2)) that were held on the arms of a universal testing machine. The appropriate CA or the self-stick adhesive system (Self-Stick Dots) (SSD) was applied to the plates, which had either no mechanical retention, or equally spaced mechanical perforations (n=4). An in vivo pilot test determined the appropriate rate of plate separation. Plates with impression material were lowered to provide 4 mm of space, the material set, and plates were separated using the appropriate speed. Force at first separation was divided by plate area (peak stress). Five replications per test condition were made, and results were analyzed using ANOVA and Bonferroni-adjusted t tests (alpha=.05). Within each impression material/test combination, stress using SSD was significantly lower than CA (P<.05). Mechanical retention did not always provide significantly greater strength. The combination of mechanical retention and CA yielded the highest strength within each material type, except for PE, for which nonmechanical and CA strength did not differ from that of mechanical and CA. Use of the self-stick adhesive system provided significantly lower retentive strength to plastic tray material than chemical adhesives for irreversible hydrocolloid, vinyl polysiloxane, and polyether.

  16. Cellulase production through solid-state tray fermentation, and its use for bioethanol from sorghum stover.

    PubMed

    Idris, Ayman Salih Omer; Pandey, Ashok; Rao, S S; Sukumaran, Rajeev K

    2017-10-01

    The production of cellulase by Trichoderma reesei RUT C-30 under solid-state fermentation (SSF) on wheat bran and cellulose was optimized employing a two stage statistical design of experiments. Optimization of process parameters resulted in a 3.2-fold increase in CMCase production to 959.53IU/gDS. The process was evaluated at pilot scale in tray fermenters and yielded 457IU/gDS using the lab conditions and indicating possibility for further improvement. The cellulase could effectively hydrolyze alkali pretreated sorghum stover and addition of Aspergillus niger β-glucosidase improved the hydrolytic efficiency 174%, indicating the potential to use this blend for effective saccharification of sorghum stover biomass. The enzymatic hydrolysate of sorghum stover was fermented to ethanol with ∼80% efficiency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Dental image replacement on cone beam computed tomography with three-dimensional optical scanning of a dental cast, occlusal bite, or bite tray impression.

    PubMed

    Kang, S-H; Lee, J-W; Lim, S-H; Kim, Y-H; Kim, M-K

    2014-10-01

    The goal of the present study was to compare the accuracy of dental image replacement on a cone beam computed tomography (CBCT) image using digital image data from three-dimensional (3D) optical scanning of a dental cast, occlusal bite, and bite tray impression. A Bracket Typodont dental model was used. CBCT of the dental model was performed and the data were converted to stereolithography (STL) format. Three experimental materials, a dental cast, occlusal bite, and bite tray impression, were optically scanned in 3D. STL files converted from the CBCT of the Typodont model and the 3D optical-scanned STL files of the study materials were image-registered. The error range of each methodology was measured and compared with a 3D optical scan of the Typodont. For the three materials, the smallest error observed was 0.099±0.114mm (mean error±standard deviation) for registering the 3D optical scan image of the dental cast onto the CBCT dental image. Although producing a dental cast can be laborious, the study results indicate that it is the preferred method. In addition, an occlusal bite is recommended when bite impression materials are used. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Mathematical modeling and assessment of microbial migration during the sprouting of alfalfa in trays in a nonuniformly contaminated seed batch using Enterobacter aerogenes as a surrogate for Salmonella Stanley.

    PubMed

    Liu, Bin; Schaffner, Donald W

    2007-11-01

    Raw seed sprouts have been implicated in several food poisoning outbreaks in the past 10 years. The U.S. Food and Drug Administration recommends that sprout growers use interventions (such as testing of spent irrigation water) to control the presence of pathogens in the finished product. During the sprouting process, initially low concentrations of pathogen may increase, and contamination may spread within a batch of sprouting seeds. A model of pathogen growth as a function of time and distance from the contamination spot during the sprouting of alfalfa in trays has been developed with Enterobacter aerogenes. The probability of detecting contamination was assessed by logistic regression at various time points and distances by sampling from sprouts or irrigation water. Our results demonstrate that microbial populations and possibility of detection were greatly reduced at distances of > or = 20 cm from the point of contamination in a seed batch during tray sprouting; however, the probability of detecting microbial contamination at distances less than 10 cm from the point of inoculation was almost 100% at the end of the sprouting process. Our results also show that sampling irrigation water, especially large volumes of water, is highly effective at detecting contamination: by collecting 100 ml of irrigation water for membrane filtration, the probability of detection was increased by three to four times during the first 6 h of seed germination. Our findings have quantified the degree to which a small level of contamination will spread throughout a tray of sprouting alfalfa seeds and subsequently be detected by either sprout or irrigation water sampling.

  19. Fungal Growth and Manganese Peroxidase Production in a Deep Tray Solid-State Bioreactor, and In Vitro Decolorization of Poly R-478 by MnP.

    PubMed

    Zhao, Xinshan; Huang, Xianjun; Yao, Juntao; Zhou, Yue; Jia, Rong

    2015-06-01

    The growth of Irpex lacteus F17 and manganese peroxidase (MnP) production in a selfdesigned tray bioreactor, operating in solid-state conditions at a laboratory scale, were studied. The bioreactor was divided into three layers by three perforated trays. Agroindustrial residues were used both as the carrier of bound mycelia and as a nutrient medium for the growth of I. lacteus F17. The maximum biomass production in the bioreactor was detected at 60 h of fermentation, which was consistent with the CO2 releasing rate by the fungus. During the stationary phase of fungal growth, the maximum MnP activity was observed, reaching 950 U/l at 84 h. Scanning electron microscopy images clearly showed the growth situation of mycelia on the support matrix. Furthermore, the MnP produced by I. lacteus F17 in the bioreactor was isolated and purified, and the internal peptide sequences were also identified with mass spectrometry. The optimal activity of the enzyme was detected at pH 7 and 25 °C, with a long half-life time of 9 days. In addition, the MnP exhibited significant stability within a broad pH range of 4-7 and at temperature up to 55 °C. Besides this, the MnP showed the ability to decolorize the polymeric model dye Poly R-478 in vitro.

  20. Reusable, tamper-indicating seal

    DOEpatents

    Ryan, Michael J.

    1978-01-01

    A reusable, tamper-indicating seal comprises a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body -- visible from outside the seal -- adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same position. A new pattern of colored balls will appear in the segregated location when the seal is relocked.

  1. Analysis of selected specimens from the STS-46 Energetic Oxygen Interaction with Materials-3 experiment

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.; Bourassa, Roger J.; Dursch, Harry W.; Pippin, H. Gary

    1995-01-01

    The Energetic Oxygen Interaction with Materials 3 (EOIM-3) experiment was flown on the STS-46 mission, which was launched on 31 Jul. 1992 and returned 8 Aug. 1992. Boeing specimens were located on both the NASA Marshall Space Flight Center (MSFC) tray and the Ballistic Missile Defense Organization (BMDO) tray integrated by the Jet Propulsion Laboratory (JPL). The EOIM-3 pallet was mounted in the Space Shuttle payload bay near the aft bulkhead. During the mission, the atomic oxygen (AO) exposure levels of specimens in these passive sample trays was about 2.3 x 10(exp 20) atoms/sq cm. The specimens also received an estimated 22 equivalent sun hours of solar exposure. In addition, it appears that the EOIM-3 pallet was exposed to a silicone contamination source and many specimens had a thin layer of silicon based deposit on their surfaces after the flight. The specimens on the MSFC tray included seven solid film lubricants, a selection of butyl rubber (B612) and silicone (S383) o-rings, three indirect scatter surfaces, and Silver/Fluorinated Ethylene Propylene (Ag/FEP) and Chemglaze A276 specimens which had previously flown on trailing edge locations of the Long Duration Exposure Facility (LDEF). The specimens on the JPL tray included composites previously flown on LDEF and two indirect scattering surfaces.

  2. Generation and detection of pulsed T-rays for use in the study of biological and bioterrorism issues

    NASA Astrophysics Data System (ADS)

    Jedju, Thomas M.; Bosacchi, Bruno; Warren, Warren S.; Nahata, Ajay; Kuenstner, Todd

    2004-09-01

    Terahertz (T-rays) spectroscopy has recently emerged as a powerful method to access a heretofore barely explored region of the electromagnetic spectrum where fundamental molecular resonances occur. Besides their importance for fundamental research, these resonances could be used as signatures in the identification of molecular species and as sensitive probes in a wide variety of molecular processes. In this paper we consider the potential of THz spectroscopy in the application to relevant biomedical and homeland security problems such as the analysis of normal and diseased tissues and the detection of toxic biomolecules. As examples, we present preliminary experimental data which suggest that THz spectroscopy: 1) can discriminate between cancerous and normal tissue, and 2) can reveal the presence of foreign substances hidden in an envelope and even allow their specific identification. This capability is of particular relevance as a straightforward homeland security tool for the detection of anthrax and other biotoxic molecules.

  3. A Multistage Fluidized Bed for the Deep Removal of Sour Gases: Proof of Concept and Tray Efficiencies

    PubMed Central

    2018-01-01

    Currently there are significant amounts of natural gas that cannot be produced and treated to meet pipeline specifications, because that would not be economically viable. This work investigates a bench scale multistage fluidized bed (MSFB) with shallow beds for sour gas removal from natural gas using a commercially available supported amine sorbent. A MSFB is regarded as a promising adsorber type for deep sour gas removal to parts per million concentrations. A series of experiments was conducted using carbon dioxide as sour gas and nitrogen to mimic natural gas. Removal below 3 mol ppm was successfully demonstrated. This indicates that gas bypassing is minor (that is, good gas–solid contacting) and that apparent adsorption kinetics are fast for the amine sorbent applied. Tray efficiencies for a chemisorption/adsorption system were reported for one of the first times. Current experiments performed at atmospheric pressure strongly indicate that deep removal is possible at higher pressures in a multistage fluidized bed. PMID:29606794

  4. A Multistage Fluidized Bed for the Deep Removal of Sour Gases: Proof of Concept and Tray Efficiencies.

    PubMed

    Driessen, Rick T; Bos, Martin J; Brilman, Derk W F

    2018-03-21

    Currently there are significant amounts of natural gas that cannot be produced and treated to meet pipeline specifications, because that would not be economically viable. This work investigates a bench scale multistage fluidized bed (MSFB) with shallow beds for sour gas removal from natural gas using a commercially available supported amine sorbent. A MSFB is regarded as a promising adsorber type for deep sour gas removal to parts per million concentrations. A series of experiments was conducted using carbon dioxide as sour gas and nitrogen to mimic natural gas. Removal below 3 mol ppm was successfully demonstrated. This indicates that gas bypassing is minor (that is, good gas-solid contacting) and that apparent adsorption kinetics are fast for the amine sorbent applied. Tray efficiencies for a chemisorption/adsorption system were reported for one of the first times. Current experiments performed at atmospheric pressure strongly indicate that deep removal is possible at higher pressures in a multistage fluidized bed.

  5. [What is hidden behind the Baking Tray Task? Study of sensibility and specificity in right-hemispheric stroke patients].

    PubMed

    Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa

    2015-12-16

    Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.

  6. Carbon XANES Data from Six Aerogel Picokeystones Cut from the Top and Bottom Sides of the Stardust Comet Sample Tray

    NASA Technical Reports Server (NTRS)

    Wirick, S.; Flynn, G. J.; Frank, D.; Sandford, S. A.; Zolensky, M. E.; Tsou, P.; Peltzer, C.; Jacobsen, C.

    2009-01-01

    Great care and a large effort was made to minimize the amount of organic matter contained within the flight aerogel used to collect Comet 81P/Wild 2 samples. Even so, by the very nature of the production process and silica aerogel s affinity for volatile organics keeping silica aerogel free from organics is a monumental task. Silica aerogel from three production batches was flown on the Stardust sample return mission. All 3 types had layered densities varying from 5mg/ml to 50 mg/ml where the densest aerogel was farthest away from the collection area. A 2 step gelation process was used to make the flight aerogel and organics used in this process were tetraethylorthosilicate, ethanol and acetonitrile. Both ammonium hydroxide and nitric acid were also used in the aerogel production process. The flight aerogel was baked at JPL at 300 C for 72 hours, most of the baking was done at atmosphere but twice a day the oven was pumped to 10 torr for hour [1]. After the aerogel was baked it was stored in a nitrogen purged cabinet until flight time. One aerogel cell was located in the SRC away from any sample collection area as a witness to possible contamination from out gassing of the space craft, re-entry gases and any other organic encounter. This aerogel was aerogel used in the interstellar collection sample tray and is the least dense of the 3 batches of aerogel flown. Organics found in the witness tile include organics containing Si-CH3 bonds, amines and PAHS. Besides organic contamination, hot spots of calcium were reported in the flight aerogel. Carbonates have been detected in comet 81P/Wild2 samples . During preflight analyses, no technique was used to analyze for carbonates in aerogel. To determine if the carbonates found in 81P/Wild2 samples were from the comet, it is necessary to analyze the flight aerogel for carbonate as well as for organics.

  7. The effects of long-duration space exposure on the mechanical properties of some carbon-reinforced resin matrix composites

    NASA Technical Reports Server (NTRS)

    Vyhnal, Richard F.

    1993-01-01

    Long Duration Exposure Facility (LDEF) Experiment A0175 involved the non-instrumented exposure of seven carbon-fiber reinforced resin-matrix advanced composite panels contained in two trays - A7 and A1. These two trays were located, respectively, on the leading and trailing faces of LDEF, obliquely oriented to the RAM (Row 9) and WAKE (Row 3) directions. The identity and location of the seven panels, which consisted of six flat laminates of the following material systems are shown: carbon/epoxy (T300/934), carbon/bismaleimide (T300/F178), and carbon/polyimide (C6000/LARC-160 and C6000/PMR-15), plus one bonded honeycomb sandwich panel (T300/934 face sheets and Nomex core) patterned after the Space Shuttle payload bay door construction. These material systems were selected to represent a range of then-available matrix resins which, by virtue of their differing polymer chemistry, could conceivably exhibit differing susceptibility to the low-earth orbit (LEO) environment. The principal exposure conditions of the LDEF environment at these tray locations are shown. Noteworthy to some of the observations discussed is the four-orders-of magnitude difference in the atomic oxygen (AO) fluence, which made a shallow incidence angle (approximately 22 deg) to Tray A7, while Tray A1 on the trailing face was essentially shielded from AO exposure. This evaluation focused on determining the individual and relative suitability of a variety of resin-matrix composite systems for long-term space structural applications. This was accomplished primarily by measuring and comparing a range of engineering mechanical properties on over 300 test coupons sectioned from the flight panels and from identical control panels, and tested at ambient and elevated temperatures. This testing was supported by limited physical characterization, involving visual examination of flight panel surface features, measurements of weight loss and warpage, and examination for changes in internal integrity (micro

  8. A sediment mesocosm experiment to determine if the remediation of a shoreline waste disposal site in Antarctica caused further environmental impacts.

    PubMed

    Stark, Jonathan S; Johnstone, Glenn J; Riddle, Martin J

    2014-12-15

    A shoreline waste disposal site at Casey Station, Antarctica was removed because it was causing impacts in the adjacent marine environment (Brown Bay). We conducted a field experiment to determine whether the excavation created further impacts. Trays of clean, defaunated sediment were deployed at two locations within Brown Bay and two control locations, two years prior to remediation. Trays were sampled one year before, 1month before, 1month after and two years after the excavation. An increase in metals was found at Brown Bay two years after the remediation. However there was little evidence of impacts on sediment assemblages. Communities at each location were different, but differences from before to after the remediation were comparable, indicating there were unlikely to have been further impacts. We demonstrate that abandoned waste disposal sites in hydrologically active places in Antarctica can be removed without creating greater adverse impacts to ecosystems downstream. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  9. Integral Fast Reactor fuel pin processor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levinskas, D.

    1993-01-01

    This report discusses the pin processor which receives metal alloy pins cast from recycled Integral Fast Reactor (IFR) fuel and prepares them for assembly into new IFR fuel elements. Either full length as-cast or precut pins are fed to the machine from a magazine, cut if necessary, and measured for length, weight, diameter and deviation from straightness. Accepted pins are loaded into cladding jackets located in a magazine, while rejects and cutting scraps are separated into trays. The magazines, trays, and the individual modules that perform the different machine functions are assembled and removed using remote manipulators and master-slaves.

  10. Integral Fast Reactor fuel pin processor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levinskas, D.

    1993-03-01

    This report discusses the pin processor which receives metal alloy pins cast from recycled Integral Fast Reactor (IFR) fuel and prepares them for assembly into new IFR fuel elements. Either full length as-cast or precut pins are fed to the machine from a magazine, cut if necessary, and measured for length, weight, diameter and deviation from straightness. Accepted pins are loaded into cladding jackets located in a magazine, while rejects and cutting scraps are separated into trays. The magazines, trays, and the individual modules that perform the different machine functions are assembled and removed using remote manipulators and master-slaves.

  11. Rainfall intensity and phosphorus source effects on phosphorus transport in surface runoff from soil trays.

    PubMed

    Shigaki, Francirose; Sharpley, Andrew; Prochnow, Luis Ignacio

    2007-02-01

    Phosphorus runoff from agricultural fields amended with mineral fertilizers and manures has been linked to freshwater eutrophication. A rainfall simulation study was conducted to evaluate the effects of different rainfall intensities and P sources differing in water soluble P (WSP) concentration on P transport in runoff from soil trays packed with a Berks loam and grassed with annual ryegrass (Lolium multiflorum Lam.). Triple superphosphate (TSP; 79% WSP), low-grade super single phosphate (LGSSP; 50% WSP), North Carolina rock phosphate (NCRP; 0.5% WSP) and swine manure (SM; 70% WSP), were broadcast (100 kg total P ha-1) and rainfall applied at 25, 50 and 75 mm h-1 1, 7, 21, and 56 days after P source application. The concentration of dissolved reactive (DRP), particulate (PP), and total P (TP) was significantly (P<0.01) greater in runoff with a rainfall intensity of 75 than 25 mm h-1 for all P sources. Further, runoff DRP increased as P source WSP increased, with runoff from a 50 mm h-1 rain 1 day after source application having a DRP concentration of 0.25 mg L-1 for NCRP and 28.21 mg L-1 for TSP. In contrast, the proportion of runoff TP as PP was greater with low (39% PP for NCRP) than high WSP sources (4% PP for TSP) averaged for all rainfall intensities. The increased PP transport is attributed to the detachment and transport of undissolved P source particles during runoff. These results show that P source water solubility and rainfall intensity can influence P transport in runoff, which is important in evaluating the long-term risks of P source application on P transport in surface runoff.

  12. Location, Location, Location: Where Do Location-Based Services Fit into Your Institution's Social Media Mix?

    ERIC Educational Resources Information Center

    Nekritz, Tim

    2011-01-01

    Foursquare is a location-based social networking service that allows users to share their location with friends. Some college administrators have been thinking about whether and how to take the leap into location-based services, which are also known as geosocial networking services. These platforms, which often incorporate gaming elements like…

  13. Change during Psychotherapy through Sand Play Tray in Children That Have Been Sexually Abused

    PubMed Central

    Tornero, María D. L. Angeles; Capella, Claudia

    2017-01-01

    This paper presents the results of a qualitative study on the use of sandplay, or sand tray therapy, in the psychotherapeutic process of children who have been sexually abused. A longitudinal study was carried out with seven participants between the ages of 7 and 10 years old. Data was produced during observation of the therapeutic activity over the course of three different phases of treatment, using a rubric created especially for this observation. Three sandplay sessions were recorded: one at the start of therapy, one at the 3-month mark, and the third and final session after 6 months of treatment. Sessions were then transcribed for later analysis. A rubric was developed in order to help researchers identify central themes, behaviors and content of creative play, as well as the therapeutic relationship. Transcribed sessions and observation rubrics were evaluated using qualitative content analysis, and information was categorized according to verbal and behavioral characteristics of the game. Results of the present study reveal common and transversal forms of playful expression among this group of children shown by their engagement with sandplay. During this activity, participants elaborate personal stories that feature violence as a central theme, often involving aggression between two or more individuals. They also express their need for care and protection and work to resolve conflicts using fantasy. The shifting dynamics of sandplay at each stage of therapeutic treatment is an important finding that reveals the progress made during psychotherapy. In the third phase of treatment, sandplay encouraged movement among children, allowing them to act out meaningful scenarios and create structured situations with positive outcomes. Finally, the value of sandplay as an important therapeutic tool is discussed, primarily its role in supporting processes of change and allowing participants to assign new meanings to traumatic experiences. Its application to the field of

  14. Location, Location, Location!

    ERIC Educational Resources Information Center

    Ramsdell, Kristin

    2004-01-01

    Of prime importance in real estate, location is also a key element in the appeal of romances. Popular geographic settings and historical periods sell, unpopular ones do not--not always with a logical explanation, as the author discovered when she conducted a survey on this topic last year. (Why, for example, are the French Revolution and the…

  15. Transfer of location-specific control to untrained locations.

    PubMed

    Weidler, Blaire J; Bugg, Julie M

    2016-11-01

    Recent research highlights a seemingly flexible and automatic form of cognitive control that is triggered by potent contextual cues, as exemplified by the location-specific proportion congruence effect--reduced compatibility effects in locations associated with a high as compared to low likelihood of conflict. We investigated just how flexible location-specific control is by examining whether novel locations effectively cue control for congruency-unbiased stimuli. In two experiments, biased (mostly compatible or mostly incompatible) training stimuli appeared in distinct locations. During a final block, unbiased (50% compatible) stimuli appeared in novel untrained locations spatially linked to biased locations. The flanker compatibly effect was reduced for unbiased stimuli in novel locations linked to a mostly incompatible compared to a mostly compatible location, indicating transfer. Transfer was observed when stimuli appeared along a linear function (Experiment 1) or in rings of a bullseye (Experiment 2). The novel transfer effects imply that location-specific control is more flexible than previously reported and further counter the complex stimulus-response learning account of location-specific proportion congruence effects. We propose that the representation and retrieval of control settings in untrained locations may depend on environmental support and the presentation of stimuli in novel locations that fall within the same categories of space as trained locations.

  16. Location, Location, Location: Does Place Provide the Opportunity for Differentiation for Universities?

    ERIC Educational Resources Information Center

    Winter, Emma; Thompson-Whiteside, Helen

    2017-01-01

    The fiercely competitive HE market has led HEIs to invest significant resources in building a distinct identity. An HEI's location forms an inherent part of its identity and the uniqueness of location offers an opportunity to differentiate. However there has been limited examination of how location is used by HEIs and little consideration of how…

  17. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.

    PubMed

    Kang, Alex H; Johnson, Glen H; Lepe, Xavier; Wataha, John C

    2009-05-01

    A common technique used for making crown impressions involves use of a vinyl polysiloxane impression material in combination with a dual-arch tray. A leading dental manufacturer has reformulated its vinyl polysiloxane (VPS) impression line, but the accuracy of the new material has not been verified. The purpose of this study was to assess the accuracy of reformulated VPS impression materials using the single-step dual-arch impression technique. Dual-arch impressions were made on a typodont containing a master stainless steel standard crown preparation die, from which gypsum working dies were formed, recovered, and measured. The impression materials evaluated were Imprint 3 Penta Putty with Quick Step Regular Body (IP-0); Imprint 3 Penta Quick Step Heavy Body with Quick Step Light Body (IP-1); Aquasil Ultra Rigid Fast Set with LV Fast Set (AQ-1); and Aquasil Ultra Heavy Fast Set with XLV Fast Set (AQ-2) (n=10). All impressions were disinfected with CaviCide spray for 10 minutes prior to pouring with type IV gypsum. Buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions were measured and compared to the master die using an optical measuring microscope. Linear dimensional change was also assessed for IP-0 and AQ-1 at 1 and 24 hours based on ANSI/ADA Specification No. 19. Single-factor ANOVA with Dunnett's T3 multiple comparisons was used to compare BL, MD, and OG changes, with hypothesis testing at alpha=.05. A repeated-measures ANOVA was used to compare linear dimensional changes. There were statistical differences among the 4 impression systems for 3 of 4 dimensions of the master die. IP-0 working dies were significantly larger in MD and OG-L dimensions but significantly smaller in the BL dimension. IP-1 working dies were significantly smaller in the BL dimension compared to the master die. With the exception of IP-0, differences detected were small and clinically insignificant. No significant differences were observed for linear dimensional change

  18. Experimental study of cassava sun drying

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Njie, D.N.; Rumsey, T.R.

    1997-03-01

    Sun drying experiments were performed to compare drying of cassava chips in sheet-metal trays with drying on mesh wire trays. In the sheet-metal trays, there was air flow across the top of the bed chips, while the mesh wire trays permitted air to flow through the bed. Drying rate was faster and more uniform in the trays with through-flow air circulation. Higher temperatures were reached by chips in the sheet-metal trays than those in the mesh trays because of contact heating, but the drying rate was lower because of the reduced air flow.

  19. 29 CFR 1910.306 - Specific purpose equipment and installations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... means required by paragraph (e)(1) of this section. (f) X-Ray equipment. This paragraph applies to X-ray... disconnecting means shall be operable from a location readily accessible from the X-ray control. For equipment... suitable nonmetallic raceways or cable trays; or (C) Wire or cable in suitable metal raceways or metal...

  20. 29 CFR 1910.306 - Specific purpose equipment and installations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... means required by paragraph (e)(1) of this section. (f) X-Ray equipment. This paragraph applies to X-ray... disconnecting means shall be operable from a location readily accessible from the X-ray control. For equipment... suitable nonmetallic raceways or cable trays; or (C) Wire or cable in suitable metal raceways or metal...

  1. A Proposed Combat Food Service System Concept for the Army in 1990

    DTIC Science & Technology

    1980-01-01

    Tray (T) 1 Froz (F) Swedish Meatballs 1 Tray (T) - 1 Froz (F) Ham - 3 Canned (B) 1 Froz (F) Roast Pork/Gravy 1 Tray (T) - - Stuffed Pork Slices...Froz (F) Beef Stew 2 Tray (T) 2 Dehy (D) 2 Froz (F) Lasagna 1 Tray (T) 2 Dry/Dehy (D) 2 Dry/Froz (F) Spaghetti/ Meatballs 1 Tray (T) 2 Dry/Dehy (D) 1...Breakfast Maat Entrae — B Canadian Bacon Bacon Ham Slices Sausage Mon Meat Entree — B Eggs Cheese Omelet French Toast Pancakes Starch - B

  2. Cassegrain Solar Concentrator System for ISRU Material Processing

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Macosko, Robert; Castle, Charles; Sacksteder, Kurt; Suzuki, Nantel H.; Mulherin, James

    2012-01-01

    A 0.5 m diameter Cassegrain concentrator was constructed as a means of providing highly concentrated sunlight for the demonstration processing of lunar simulated regolith and other NASA In-Situ Resource Utilization Project (ISRU) reaction processes. The concentrator is constructed of aluminum with a concentration ratio of approximately 3000 to 1. The concentrator focuses solar energy into a movable tray located behind the concentrator. This tray can hold simulated regolith or any other material and or device to be tested with concentrated solar energy. The tray is movable in one axis. A 2-axis extended optical system was also designed and fabricated. The extended optical system is added to the back of the primary concentrator in place of the moveable test tray and associated apparatus. With this optical system the focused sunlight can be extended from the back of the primary concentrator toward the ground with the added advantage of moving the focal point axially and laterally relative to the ground. This allows holding the focal point at a fixed position on the ground as the primary concentrator tracks the sun. Also, by design, the focal point size was reduced via the extended optics by a factor of 2 and results in a concentration ratio for the system of approximately 6,000 to 1.The designs of both optical systems are discussed. The results from simulated regolith melting tests are presented as well as the operational experience of utilizing the Cassegrain concentrator system.

  3. Evaluation of the success rate of cone beam computed tomography in determining the location and direction of screw access holes in cement-retained implant-supported prostheses: An in vitro study.

    PubMed

    Neshandar Asli, Hamid; Dalili Kajan, Zahra; Gholizade, Fatemeh

    2018-02-21

    Cement-retained implant-supported restorations have advantages over screw-retained restorations but are difficult to retrieve. Identifying the approximate location of the screw access hole (SAH) may reduce damage to the prosthesis. The purpose of this in vitro study was to evaluate the ability of cone beam computed tomography (CBCT) imaging to determine the location and direction of SAHs in cement-retained implant prostheses. Five clear acrylic resin casts were made based on a mandibular model. Several implant osteotomies (n=30) were created on the models with surgical burs, and crowns were made using the standard laboratory method with a transfer coping and the closed tray impression technique. CBCT images from the acrylic resin casts were evaluated by a maxillofacial radiologist who was blind to the locations and angles of the osteotomies. The locations of the access holes were determined on multiplanar reconstruction images and transferred to the clinical crown surface as defined points. Based on cross-sectional images, the predicted angle of the access hole was provided to a prosthodontist who was requested to pierce the crown at the proposed location in the specified direction. If the location and/or direction of the access hole were found, the process was considered successful, as the crown could then be removed from the implant abutment through the SAH. The success rate in the detection of the location and direction of the SAH was calculated, and chi-square and Fisher exact tests were applied for data analysis (α=.05). According to the results of this study, the success rate of CBCT to define the location of SAHs was 83.3% and 80% to determine the direction. No significant differences were found among the different dental groups in determination of the location (P=.79) or the direction (P=.53) of the SAHs. Most of the failures in determining the location and direction of the access hole in the buccolingual and mesiodistal directions were in the buccal and

  4. Olefin unit primary fractionator on-line Petro-Blast Lancing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, W.D.; Rutan, C.R.

    1994-12-31

    Today`s commodity chemicals market forces companies to find innovative ways to extend unit on line operation between turnarounds such that they will remain economically competitive. At the OxyChem Chocolate Bayou facility the Primary Fractionator, quench oil column, fouling defined the length of the run between Olefin Unit turnarounds. Polymer growth on the valve trays restricted vapor flow through the column. This increased the column pressure drop which resulted in severe flooding. The inability to cool the furnace effluent while separating the fuel oil and gasoline components would cause premature shutdowns. Fouling locations were defined using gamma scan techniques and pressuremore » surveys. Nozzles were welded and hot tapped at strategic locations around the column. A high pressure Petro-Blast Lancing technique, inserted through the nozzles, was then used to clean the trays. The operation has extended the unit run length although the column may require additional Petro-Blast Lancing before the next scheduled plant turnaround. If this schedule holds, a two year extension in the unit run length will be realized.« less

  5. Micrometeoroids and debris on LDEF

    NASA Technical Reports Server (NTRS)

    Mandeville, Jean-Claude

    1992-01-01

    Part of the LDEF tray allocated to French Experiments (FRECOPA) was devoted to the study of dust particles. The tray was located on the face of LDEF directly opposed to the velocity vector. Two passive experiments were flown: a set of glass and metallic samples; and multilayer thin foil detectors. Crater size distribution made possible the evaluation of the incident microparticle flux in the near environment. Comparisons are made with measurements obtained on the other faces of LDEF and with results from similar experiments on the MIR. Of interest was the study of impact features on stacked thin foil detectors. The top foil acted as a shield, fragmenting the projectiles and spreading the fragments over the surface of the thick plate located underneath. EDS analysis has provided evidence of impactor fragments. Detectors consisting of a thin shield and thick bottom plate appear to offer a significantly higher return of data concerning chemical analysis of impactor residues than single plate detectors. The samples of various materials offer a unique opportunity for the study of the many processes involved upon hypervelocity impact phenomena.

  6. Quality of fresh-cut baby spinach grown under a floating trays system as affected by nitrogen fertilisation and innovative packaging treatments.

    PubMed

    Rodríguez-Hidalgo, Stephanie; Artés-Hernández, Francisco; Gómez, Perla A; Fernández, Juan Antonio; Artés, Francisco

    2010-04-30

    Alternative techniques for cultivation of leafy vegetables such as a floating tray system and unconventional gas mixtures for post-harvest active modified atmosphere packaging (MAP) could be of interest in the minimally processed vegetable industry. The combined effect of three pre-harvest fertilisation doses (8, 12 or 16 mmol N L(-1)) and three post-harvest MAP conditions (passive, super-atmospheric or N2O-enriched) on the main quality attributes of fresh-cut baby spinach leaves throughout 10 days at 5 degrees C was studied. After 8 days of shelf life, spinach leaves fertilised with 8 and 16 mmol N L(-1) and stored under N2O-enriched MAP showed the lowest microbial growth, with good sensory quality. Such combined treatments also preserved the total antioxidant capacity sampled at harvest (8 g ascorbic acid equivalent antioxidant capacity kg(-1) f.w.). A decrease of 10-20% in total vitamin C content regardless of N fertilisation and packaging treatment was found during shelf life. Total phenolics content at harvest was 2 g gallic acid equivalents kg(-1) f.w., which was slightly decreased or preserved during shelf life while total chlorophylls were preserved for all treatments assayed around 550 mg kg(-1) f.w. No clear effect of fertilisation doses was observed during post-harvest storage on overall quality of fresh-cut baby spinach leaves, while N2O-enriched atmospheres seems to be a promising alternative to passive MAP for extending shelf life.

  7. [Solid phase radioimmunoassay for plasma testosterone using plastic microtiter tray (author's transl)].

    PubMed

    Hosogi, H

    1975-03-20

    In order to simply radioimmunoassay for plasma testosterone and to measure many samples at the same time, a method of solid phase radioimmunoassay utilizing a plastic disposable microtiter tray (DMT) by which chromatography can be omitted was investigated. The antiserum was obtained by immunizing rabbits with testosterone-3 BSA which had been synthesized according to the Erlarnger's method. Plasma samples (male: 0.05ml, female: 0.2 ml) were extracted with 1.0 ml of ether. After freezing the plasma layer in an acetone-dryice bath, the ether phase was transfered to a glass tube and evaporated to dryness. These samples and the dried standard testosterone were dissolved with borate buffer containing 3H-testosterone and transfered to plastic DMT which had been precoated with the diluted antiserum, and incubated for 24 hrs. After removal of the incubated solution, the cups of DMT were cut off and were dissolved with toluene scintillator in counting vials. The radioactivity was counted with a liquid scintillation counter. Other steroids except for 5alpha-dihydrotestosterone (5alpha-DHT) had a low degree of cross reactivity with the antiserum. Five alpha-DHT which could be measured together with testosterone in this assay was not a problem clinically because of its strong androgenic activity. The best standard curve was obtained when the antiserum was diluted to 1:1000. The sensitivity of this assay was 10 pg/tube. The maximal adsorption of antibody to plastic DMT was observed when the pH of antiserum was within the range of 6.5-9.5 and the precoating time was 24 hr at room termperature. The best pH of incubation buffer was 8.0, and the antigen-antibody reaction became a plateau when the incubation exceeded 6 hrs. Water blank in this assay was 4.6 +/- 2.1 pg/tube. The recovery of testosterone (50, 100, 200 pg) added to 0.1 ml female plasma was 99 +/- 6.8%. Coefficients of variation within assay and between assay were below 11.2% and 20.0%, respectively. Correlation between

  8. 2. RW Meyer Sugar Mill: 18761899. Threeroll sugar mill, oneton ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. RW Meyer Sugar Mill: 1876-1899. Three-roll sugar mill, one-ton daily processing capacity. Manufactured by Edwin Maw, Liverpool, England, ca. 1855-1870. View: Top roll and one bottom roll, mill housing or cheeks, and spur pinion gears. The broken projection on the mill beside the bottom roll indicates the location of the cane tray. The cane juice crushed from the cane flowed into the juice tray below the bottom rolls. It then flowed into a wooden gutter and through a short tunnel in the mill's masonry enclosure and on to the boiling house for further processing. The opening at the base of the masency wall (In the photograph) is where the gutter ran from the mill to the boiling house. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  9. Long Duration Exposure Facility (LDEF) preliminary findings: LEO space effects on the space plasma-voltage drainage experiment

    NASA Technical Reports Server (NTRS)

    Blakkolb, Brian K.; Yaung, James Y.; Henderson, Kelly A.; Taylor, William W.; Ryan, Lorraine E.

    1992-01-01

    The Space Plasma-High Voltage Drainage Experiment (SP-HVDE) provided a unique opportunity to study long term space environmental effects on materials because it was comprised of two identical experimental trays; one tray located on the ram facing side (D-10), and the other on the wake facing side (B-4) of the LDEF. This configuration allows for the comparison of identical materials exposed to two distinctly different environments. The purpose of this work is to document an assessment of the effects of five and three quarters years of low Earth orbital space exposure on materials comprising the SP-HVDE (experiment no. A0054). The findings of the materials investigation reported focus on atomic oxygen effects, micrometeor and debris impact site documentation, thermal property measurements, and environmentally induced contamination.

  10. Commander Young removes CAP from FDF stowage locker on middeck

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Commander Young removes Crew Activity Plans (CAP) from Flight Data File (FD/FDF) modular stowage locker single tray assembly located in forward middeck locker MF28E. Window shade and filter kit on port side bulkhead and potable water tank on middeck floor appear in view. Photo was taken by Pilot Crippen with a 35mm camera.

  11. SKYLAB (SL) - MANUFACTURING (FOOD)

    NASA Image and Video Library

    1971-12-30

    S72-15409 (1972) --- A close-up view of a food tray which is scheduled to be used in the Skylab program. Several packages of space food lie beside the tray. The food in the tray is ready to eat. Out of tray, starting from bottom left: grape drink, beef pot roast, chicken and rice, beef sandwiches and sugar cookie cubes. In tray, from back left: orange drink, strawberries, asparagus, prime rib, dinner roll and butterscotch pudding in the center. Photo credit: NASA

  12. Effect of technique and impression material on the vertical misfit of a screw-retained, three-unit implant bridge: An in vitro study

    PubMed Central

    Haghi, Hamidreza Rajati; Shiehzadeh, Masoud; Nakhaei, Mohammadreza; Ahrary, Fatemeh; Sabzevari, Saeid

    2017-01-01

    Introduction: A dental impression is a negative imprint of an oral structure that can be used to produce a positive cast of a patient's teeth as a permanent record. The accuracy of the impression affects the accuracy of the cast, and a precise impression is needed in order to create prosthesis with optimal fitting. Minimization of misfit is an important aim in prosthesis science and dental implants. The aim of this study was to evaluate the effects of the materials and techniques used to take an impression on the vertical misfit of implant-supported, screw-retained, three-unit bridges. Materials and Methods: The principal model used was an acrylic block with two ITI implants. A 1.5-mm abutment was attached to fixtures with torque of 25 N.cm. A base-metal framework was built on the abutment in the acrylic block. The abutments of the acrylic model were unscrewed and fixture-level impressions were made. The impression techniques included open/closed-tray techniques and the impression materials were polyether and polyvinyl siloxane. Forty acrylic custom trays were built for each impression. The marginal gap in the framework at three points (buccal, lingual, and distal) was measured using an optical microscope with ×250. Results: It is demonstrated that in all 360 evaluated samples, the mean vertical misfit in polyether samples of molar and premolar teeth was significantly lower than in polyvinyl siloxane (P < 0.001 and P = 0.017, respectively) in all three locations of the molar and lingual premolar examined (buccal, lingual, and distal), the mean vertical misfit of the polyether samples was significantly lower than those of polyvinyl siloxane (P < 0.01). On the other hand, although the mean vertical misfit using the open-tray technique in the molar teeth was significantly lower than with the closed-tray method (P = 0.002), no statistical difference was seen between the open-tray and closed-tray technique in general (P = 0.87). Conclusion: Within the limitations of

  13. Location, location, location: does early cancer in Barrett's esophagus have a preference?

    PubMed

    Enestvedt, Brintha K; Lugo, Ricardo; Guarner-Argente, Carlos; Shah, Pari; Falk, Gary W; Furth, Emma; Ginsberg, Gregory G

    2013-09-01

    Early cancer (high-grade dysplasia [HGD] and intramucosal carcinoma [ImCa]) associated with Barrett's esophagus (BE) may have a circumferential spatial predilection. To describe the esophageal circumferential location of early cancer in BE. Retrospective study, single tertiary referral center. One hundred nineteen patients were referred for endoscopic eradication therapy for early cancer associated with BE. Endoscopic images and reports and pathology were reviewed. Circumferential location designation of early cancer in BE by using a clock-face orientation. One hundred nineteen of 131 patients referred for endoscopic eradication therapy had a location designation for their advanced histology (91.9%). There were a total of 57 patients (47.9%) with HGD and 62 patients (52.1%) with ImCa. There was a significantly higher rate of early cancer (HGD or ImCa) in the right hemisphere (12 to 6 o'clock location) compared with the left hemisphere (84.9% vs 15.1%, P < .0001). The highest percentage of early cancer was found in the 12 to 3 o'clock quadrant (64.7%); 71.9% of HGD and 58.1% of ImCa lesions were located in the 12 to 3 o'clock quadrant. Retrospective design, single center. Early cancer associated with BE is far more commonly found in the right hemisphere of the esophagus (12 to 6 o'clock) with the highest rate in the 12 to 3 o'clock quadrant. These findings support enhanced scrutiny of the right hemisphere of the esophagus during surveillance and endoscopic treatment of patients with BE. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  14. The Sense of 1PP-Location Contributes to Shaping the Perceived Self-location Together with the Sense of Body-Location.

    PubMed

    Huang, Hsu-Chia; Lee, Yen-Tung; Chen, Wen-Yeo; Liang, Caleb

    2017-01-01

    Self-location -the sense of where I am in space-provides an experiential anchor for one's interaction with the environment. In the studies of full-body illusions, many researchers have defined self-location solely in terms of body-location -the subjective feeling of where my body is. Although this view is useful, there is an issue regarding whether it can fully accommodate the role of 1PP-location -the sense of where my first-person perspective is located in space. In this study, we investigate self-location by comparing body-location and 1PP-location: using a head-mounted display (HMD) and a stereo camera, the subjects watched their own body standing in front of them and received tactile stimulations. We manipulated their senses of body-location and 1PP-location in three different conditions: the participants standing still (Basic condition), asking them to move forward (Walking condition), and swiftly moving the stereo camera away from their body (Visual condition). In the Walking condition, the participants watched their body moving away from their 1PP. In the Visual condition, the scene seen via the HMD was systematically receding. Our data show that, under different manipulations of movement, the spatial unity between 1PP-location and body-location can be temporarily interrupted. Interestingly, we also observed a "double-body effect." We further suggest that it is better to consider body-location and 1PP-location as interrelated but distinct factors that jointly support the sense of self-location.

  15. Cost Savings of Standardization of Thoracic Surgical Instruments: The Process of Lean.

    PubMed

    Cichos, Kyle H; Linsky, Paul L; Wei, Benjamin; Minnich, Douglas J; Cerfolio, Robert J

    2017-12-01

    Our objective is to show the effect that standardization of surgical trays has on the number of instruments sterilized and on cost. We reviewed our most commonly used surgical trays with the 3 general thoracic surgeons in our division and agreed upon the least number of surgical instruments needed for mediastinoscopy, video-assisted thoracoscopic surgery, robotic thoracic surgery, and thoracotomy. We removed 59 of 79 instruments (75%) from the mediastinoscopy tray, 45 of 73 (62%) from the video-assisted thoracoscopic surgery tray, 51 of 84 (61%) from the robotic tray, and 50 of 113 (44%) from the thoracotomy tray. From January 2016 to December 2016, the estimated savings by procedure were video-assisted thoracoscopic surgery (n = 398) $21,890, robotic tray (n = 231) $19,400, thoracotomy (n = 163) $15,648, and mediastinoscopy (n = 162) $12,474. Estimated total savings were $69,412. The weight of the trays was reduced 70%, and the nonsteamed sterilization rate (opened trays that needed to be reprocessed) decreased from 2% to 0%. None of the surgeons requested any of the removed instruments. Standardization of thoracic surgical trays is possible despite having multiple thoracic surgeons. This process of lean (the removal of nonvalue steps or equipment) reduces the number of instruments cleaned and carried and reduces cost. It may also reduce the incidence of "wet loads" that require the resterilization of instruments. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Reversible micromachining locator

    DOEpatents

    Salzer, Leander J.; Foreman, Larry R.

    1999-01-01

    This invention provides a device which includes a locator, a kinematic mount positioned on a conventional tooling machine, a part carrier disposed on the locator and a retainer ring. The locator has disposed therein a plurality of steel balls, placed in an equidistant position circumferentially around the locator. The kinematic mount includes a plurality of magnets which are in registry with the steel balls on the locator. In operation, a blank part to be machined is placed between a surface of a locator and the retainer ring (fitting within the part carrier). When the locator (with a blank part to be machined) is coupled to the kinematic mount, the part is thus exposed for the desired machining process. Because the locator is removably attachable to the kinematic mount, it can easily be removed from the mount, reversed, and reinserted onto the mount for additional machining. Further, the locator can likewise be removed from the mount and placed onto another tooling machine having a properly aligned kinematic mount. Because of the unique design and use of magnetic forces of the present invention, positioning errors of less than 0.25 micrometer for each machining process can be achieved.

  17. Reversible micromachining locator

    DOEpatents

    Salzer, L.J.; Foreman, L.R.

    1999-08-31

    This invention provides a device which includes a locator, a kinematic mount positioned on a conventional tooling machine, a part carrier disposed on the locator and a retainer ring. The locator has disposed therein a plurality of steel balls, placed in an equidistant position circumferentially around the locator. The kinematic mount includes a plurality of magnets which are in registry with the steel balls on the locator. In operation, a blank part to be machined is placed between a surface of a locator and the retainer ring (fitting within the part carrier). When the locator (with a blank part to be machined) is coupled to the kinematic mount, the part is thus exposed for the desired machining process. Because the locator is removably attachable to the kinematic mount, it can easily be removed from the mount, reversed, and reinserted onto the mount for additional machining. Further, the locator can likewise be removed from the mount and placed onto another tooling machine having a properly aligned kinematic mount. Because of the unique design and use of magnetic forces of the present invention, positioning errors of less than 0.25 micrometer for each machining process can be achieved. 7 figs.

  18. Criterion validity of the visual estimation method for determining patients' meal intake in a community hospital.

    PubMed

    Kawasaki, Yui; Sakai, Masashi; Nishimura, Kazuhiro; Fujiwara, Keiko; Fujisaki, Kahori; Shimpo, Misa; Akamatsu, Rie

    2016-12-01

    The accuracy of the visual estimation method is unknown, even though it is commonly used in hospitals to measure the dietary intake of patients. We aimed to compare the difference in the validity of visual estimation according to the raters' job categories and tray divisions, and to demonstrate associations between meal characteristics and validity of visual estimation in a usual clinical setting in a community hospital. We collected patients' dietary intake data in usual clinical settings for each tray in 3 ways: visual estimation by nursing assistants, visual estimation by dietitians, and weighing by researchers (reference method). Dietitians estimated the dietary intake using 2 divisions, namely, whole tray and food items. Then we compared the weights and visual estimation data to evaluate the validity of the visual estimation method. Mean nutrient consumption of target trays was significantly different when using the visual estimation of target trays than when using the weighed method (visual estimation by nursing assistants [589 ± 168 kcal, 24.3 ± 7.0 g/tray, p < 0.01], dietitians' whole trays [561 ± 171 kcal, 23.0 ± 6.9 g/tray, p < 0.05], food items [562 ± 171 kcal/tray, p < 0.05], and dietitians' food items [23.4 ± 7.3 g/tray, p = 0.63]). Spearman's correlations for both methods were very high for energy (ρ = 0.91-0.98, p < 0.01) and protein intakes (ρ = 0.88-0.96, p < 0.01), respectively. The limits of agreement in the Bland-Altman plot for both dietary intake categories were -121 kcal to 147 kcal/tray and -6.4 g to 7.0 g/tray (nursing assistants, whole division), -122 kcal-106 kcal/tray and -6.7 g to 5.5 g/tray (dietitians, whole divisions), and -82 kcal to 66 kcal/tray and -4.3 g to 3.9 g/tray (dietitians, food items divisions). High intake rate of grains was significantly associated with decreased odds of a difference between two methods based on the nursing assistant's whole tray evaluation

  19. Food Recognition: A New Dataset, Experiments, and Results.

    PubMed

    Ciocca, Gianluigi; Napoletano, Paolo; Schettini, Raimondo

    2017-05-01

    We propose a new dataset for the evaluation of food recognition algorithms that can be used in dietary monitoring applications. Each image depicts a real canteen tray with dishes and foods arranged in different ways. Each tray contains multiple instances of food classes. The dataset contains 1027 canteen trays for a total of 3616 food instances belonging to 73 food classes. The food on the tray images has been manually segmented using carefully drawn polygonal boundaries. We have benchmarked the dataset by designing an automatic tray analysis pipeline that takes a tray image as input, finds the regions of interest, and predicts for each region the corresponding food class. We have experimented with three different classification strategies using also several visual descriptors. We achieve about 79% of food and tray recognition accuracy using convolutional-neural-networks-based features. The dataset, as well as the benchmark framework, are available to the research community.

  20. Vertical distortion in distal extension ridges and palatal area of casts made by different techniques.

    PubMed

    Wang, H Y; Lu, Y C; Shiau, Y Y; Tsou, D

    1996-03-01

    A coordinate measurement machine with laser probe was used to measure the vertical distortion of the casts produced by use of three types of impression materials (irreversible hydrocolloid, condensation silicone, and addition silicone) and two types of trays (stock and custom trays). Results indicated that all impression groups showed positive vertical distortion (ranging from 0.00566 to 0.30299 mm) at the edentulous ridges and palatal area. The amount of the vertical distortion was greatest at the palatal area and was followed by the high edentulous ridge and the low edentulous ridge. Addition silicone, with either custom tray or stock tray, was the most accurate impression material. Condensation silicone was more accurate than irreversible hydrocolloid in custom tray impression. However, in stock tray impression the irreversible hydrocolloid was more accurate than the condensation silicone. The results suggest that, with careful manipulation, irreversible hydrocolloid with stock tray impression may provide a satisfactory cast for fabricating the framework of a distal extension removable partial denture.

  1. Case Series Report of 66 Refractory Maintenance Patients Evaluating the Effectiveness of Topical Oxidizing Agents.

    PubMed

    Cochrane, R Bruce; Sindelar, Betty

    2015-01-01

    To evaluate the clinical effects of a prescription tray application of hydrogen peroxide gel as an adjunct to frequent maintenance appointments for refractory periodontal patients. Case series data were analyzed from 66 failing periodontal maintenance patients who had exhausted treatment options before using prescription trays with a 1.7% hydrogen peroxide gel once or twice daily for two-and-a-half to five years. Data included pocket probing depths (PPD), bleeding on probing (BOP), smoking status, and compliance with tray usage. Data were collected prior to tray usage and after tray delivery at six months, one year, and annual intervals. A clinical and statistical reduction in BOP was maintained over the length of the study (p ≤ 0.01). No differences were seen in patients who used trays two times or one time a day or in patients who smoked or did not smoke. The 1.7% peroxide delivered via a prescription tray was most effective in shallow pockets. Aggregate PPD distribution did not change significantly. Of clinical relevance, only one tooth out of 1,745 teeth studied was lost due to periodontal disease during the study period. Prescription tray application of peroxide gel, as an adjunct to frequent periodontal maintenance appointments for refractory patients, demonstrated significant reductions in BOP'for smokers and non-smokers who used tray delivery once or twice a day.

  2. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    PubMed

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  3. Automatic inoculating apparatus. [includes movable carraige, drive motor, and swabbing motor

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1974-01-01

    An automatic inoculating apparatus for agar trays is described and using a simple inoculating element, such as a cotton swab or inoculating loop. The apparatus includes a movable carriage for supporting the tray to be inoculated, a drive motor for moving the tray along a trackway, and a swabbing motor for automatically swabbing the tray during the movement. An actuator motor controls lowering of the inoculating element onto the tray and lifting of the inoculating element. An electrical control system, including limit microswitches, enables automatic control of the actuator motor and return of the carriage to the initial position after inoculating is completed.

  4. Elemental analyses of hypervelocity microparticle impact sites on Interplanetary Dust Experiment sensor surfaces

    NASA Technical Reports Server (NTRS)

    Simon, Charles G.; Hunter, J. L.; Griffis, D. P.; Misra, V.; Ricks, D. A.; Wortman, Jim J.; Brownlee, D. E.

    1993-01-01

    The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to break down the 0.4 or 1.0 micron thick SIO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle impact sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results were used to classify the particles' origins as 'manmade,' 'natural,' or 'indeterminate.' The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters of these features. Thus far a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF have been analyzed: 36 from tray C-9 (Leading (ram), or East, side), 18 from tray C-3

  5. Elemental Analyses of Hypervelocity Microparticle Impact Sites on Interplanetary Dust Experiment Sensor Surfaces

    NASA Technical Reports Server (NTRS)

    Simon, C. G.; Hunter, J. L.; Griffis, D. P.; Misra, V.; Ricks, D. A.; Wortman, J. J.; Brownlee, D. E.

    1992-01-01

    The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to breakdown the 0.4 or 1.0 micron thick SiO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results classification resulted from the particles' origins as 'manmade', 'natural', or 'indeterminate'. The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters, of these features. Thus far, a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF were analyzed: 36 from tray C-9 (Leading (ram), or east, side), 18 from tray C-3 (Trailing

  6. Protein (multi-)location prediction: using location inter-dependencies in a probabilistic framework

    PubMed Central

    2014-01-01

    Motivation Knowing the location of a protein within the cell is important for understanding its function, role in biological processes, and potential use as a drug target. Much progress has been made in developing computational methods that predict single locations for proteins. Most such methods are based on the over-simplifying assumption that proteins localize to a single location. However, it has been shown that proteins localize to multiple locations. While a few recent systems attempt to predict multiple locations of proteins, their performance leaves much room for improvement. Moreover, they typically treat locations as independent and do not attempt to utilize possible inter-dependencies among locations. Our hypothesis is that directly incorporating inter-dependencies among locations into both the classifier-learning and the prediction process can improve location prediction performance. Results We present a new method and a preliminary system we have developed that directly incorporates inter-dependencies among locations into the location-prediction process of multiply-localized proteins. Our method is based on a collection of Bayesian network classifiers, where each classifier is used to predict a single location. Learning the structure of each Bayesian network classifier takes into account inter-dependencies among locations, and the prediction process uses estimates involving multiple locations. We evaluate our system on a dataset of single- and multi-localized proteins (the most comprehensive protein multi-localization dataset currently available, derived from the DBMLoc dataset). Our results, obtained by incorporating inter-dependencies, are significantly higher than those obtained by classifiers that do not use inter-dependencies. The performance of our system on multi-localized proteins is comparable to a top performing system (YLoc+), without being restricted only to location-combinations present in the training set. PMID:24646119

  7. Protein (multi-)location prediction: using location inter-dependencies in a probabilistic framework.

    PubMed

    Simha, Ramanuja; Shatkay, Hagit

    2014-03-19

    Knowing the location of a protein within the cell is important for understanding its function, role in biological processes, and potential use as a drug target. Much progress has been made in developing computational methods that predict single locations for proteins. Most such methods are based on the over-simplifying assumption that proteins localize to a single location. However, it has been shown that proteins localize to multiple locations. While a few recent systems attempt to predict multiple locations of proteins, their performance leaves much room for improvement. Moreover, they typically treat locations as independent and do not attempt to utilize possible inter-dependencies among locations. Our hypothesis is that directly incorporating inter-dependencies among locations into both the classifier-learning and the prediction process can improve location prediction performance. We present a new method and a preliminary system we have developed that directly incorporates inter-dependencies among locations into the location-prediction process of multiply-localized proteins. Our method is based on a collection of Bayesian network classifiers, where each classifier is used to predict a single location. Learning the structure of each Bayesian network classifier takes into account inter-dependencies among locations, and the prediction process uses estimates involving multiple locations. We evaluate our system on a dataset of single- and multi-localized proteins (the most comprehensive protein multi-localization dataset currently available, derived from the DBMLoc dataset). Our results, obtained by incorporating inter-dependencies, are significantly higher than those obtained by classifiers that do not use inter-dependencies. The performance of our system on multi-localized proteins is comparable to a top performing system (YLoc+), without being restricted only to location-combinations present in the training set.

  8. Reversible micromachining locator

    DOEpatents

    Salzer, Leander J.; Foreman, Larry R.

    2002-01-01

    A locator with a part support is used to hold a part onto the kinematic mount of a tooling machine so that the part can be held in or replaced in exactly the same position relative to the cutting tool for machining different surfaces of the part or for performing different machining operations on the same or different surfaces of the part. The locator has disposed therein a plurality of steel balls placed at equidistant positions around the planar surface of the locator and the kinematic mount has a plurality of magnets which alternate with grooves which accommodate the portions of the steel balls projecting from the locator. The part support holds the part to be machined securely in place in the locator. The locator can be easily detached from the kinematic mount, turned over, and replaced onto the same kinematic mount or another kinematic mount on another tooling machine without removing the part to be machined from the locator so that there is no need to touch or reposition the part within the locator, thereby assuring exact replication of the position of the part in relation to the cutting tool on the tooling machine for each machining operation on the part.

  9. The Sense of 1PP-Location Contributes to Shaping the Perceived Self-location Together with the Sense of Body-Location

    PubMed Central

    Huang, Hsu-Chia; Lee, Yen-Tung; Chen, Wen-Yeo; Liang, Caleb

    2017-01-01

    Self-location—the sense of where I am in space—provides an experiential anchor for one's interaction with the environment. In the studies of full-body illusions, many researchers have defined self-location solely in terms of body-location—the subjective feeling of where my body is. Although this view is useful, there is an issue regarding whether it can fully accommodate the role of 1PP-location—the sense of where my first-person perspective is located in space. In this study, we investigate self-location by comparing body-location and 1PP-location: using a head-mounted display (HMD) and a stereo camera, the subjects watched their own body standing in front of them and received tactile stimulations. We manipulated their senses of body-location and 1PP-location in three different conditions: the participants standing still (Basic condition), asking them to move forward (Walking condition), and swiftly moving the stereo camera away from their body (Visual condition). In the Walking condition, the participants watched their body moving away from their 1PP. In the Visual condition, the scene seen via the HMD was systematically receding. Our data show that, under different manipulations of movement, the spatial unity between 1PP-location and body-location can be temporarily interrupted. Interestingly, we also observed a “double-body effect.” We further suggest that it is better to consider body-location and 1PP-location as interrelated but distinct factors that jointly support the sense of self-location. PMID:28352241

  10. Cable-fault locator

    NASA Technical Reports Server (NTRS)

    Cason, R. L.; Mcstay, J. J.; Heymann, A. P., Sr.

    1979-01-01

    Inexpensive system automatically indicates location of short-circuited section of power cable. Monitor does not require that cable be disconnected from its power source or that test signals be applied. Instead, ground-current sensors are installed in manholes or at other selected locations along cable run. When fault occurs, sensors transmit information about fault location to control center. Repair crew can be sent to location and cable can be returned to service with minimum of downtime.

  11. Leak locating microphone, method and system for locating fluid leaks in pipes

    DOEpatents

    Kupperman, David S.; Spevak, Lev

    1994-01-01

    A leak detecting microphone inserted directly into fluid within a pipe includes a housing having a first end being inserted within the pipe and a second opposed end extending outside the pipe. A diaphragm is mounted within the first housing end and an acoustic transducer is coupled to the diaphragm for converting acoustical signals to electrical signals. A plurality of apertures are provided in the housing first end, the apertures located both above and below the diaphragm, whereby to equalize fluid pressure on either side of the diaphragm. A leak locating system and method are provided for locating fluid leaks within a pipe. A first microphone is installed within fluid in the pipe at a first selected location and sound is detected at the first location. A second microphone is installed within fluid in the pipe at a second selected location and sound is detected at the second location. A cross-correlation is identified between the detected sound at the first and second locations for identifying a leak location.

  12. Private Information Retrieval Techniques for Enabling Location Privacy in Location-Based Services

    NASA Astrophysics Data System (ADS)

    Khoshgozaran, Ali; Shahabi, Cyrus

    The ubiquity of smartphones and other location-aware hand-held devices has resulted in a dramatic increase in popularity of location-based services (LBS) tailored to user locations. The comfort of LBS comes with a privacy cost. Various distressing privacy violations caused by sharing sensitive location information with potentially malicious services have highlighted the importance of location privacy research aiming to protect user privacy while interacting with LBS.

  13. Influence of Proportion and Size of Sugarcane Bagasse Fiber on the Properties of Sweet Potato Starch Foams

    NASA Astrophysics Data System (ADS)

    Cruz-Tirado, J. P.; Tapia-Blácido, Delia R.; Siche, Raúl

    2017-08-01

    The objective of this work was the proportion and size of cane bagasse fiber in the physical (density and thickness), mechanical (flexural strength and tensile at break) and thermal (TG and DTG) properties of trays made from sweet potato starch. A fiber size of 75-45 µm and a 2.5% ratio allowed to obtain trays with low thicknesses and densities, but with more compact structures that improved the mechanical properties of trays made from sweet potato starch alone. In addition, higher thermal stability and lower decomposition rate are shown for trays with fiber size 75-45 µm and ratios of 2.5% and 5%. These results show that the smaller fiber size improves the properties of the sweet potato starch trays and that these trays can be used to replace the expanded polymer (EPS) for use in dry foods.

  14. 78 FR 23137 - Implementation of Full-Service Intelligent Mail Requirements for Automation Prices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-18

    ..., which provides high-value services and enables efficient mail processing. Mailings must bear Intelligent Mail barcodes on mailpieces, trays, and containers, where applicable. Also, mailers must submit mailing... Intelligent Mail tray barcodes (IMtb) on trays, tubs, and sacks. Apply unique Intelligent Mail container...

  15. Ballasted photovoltaic module and module arrays

    DOEpatents

    Botkin, Jonathan [El Cerrito, CA; Graves, Simon [Berkeley, CA; Danning, Matt [Oakland, CA

    2011-11-29

    A photovoltaic (PV) module assembly including a PV module and a ballast tray. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes an arm. The ballast tray is adapted for containing ballast and is removably associated with the PV module in a ballasting state where the tray is vertically under the PV laminate and vertically over the arm to impede overt displacement of the PV module. The PV module assembly can be installed to a flat commercial rooftop, with the PV module and the ballast tray both resting upon the rooftop. In some embodiments, the ballasting state includes corresponding surfaces of the arm and the tray being spaced from one another under normal (low or no wind) conditions, such that the frame is not continuously subjected to a weight of the tray.

  16. Location-based prospective memory.

    PubMed

    O'Rear, Andrea E; Radvansky, Gabriel A

    2018-02-01

    This study explores location-based prospective memory. People often have to remember to do things when in a particular location, such as buying tissues the next time they are in the supermarket. For event cognition theory, location is important for structuring events. However, because event cognition has not been used to examine prospective memory, the question remains of how multiple events will influence prospective memory performance. In our experiments, people delivered messages from store to store in a virtual shopping mall as an ongoing task. The prospective tasks were to do certain activities in certain stores. For Experiment 1, each trial involved one prospective memory task to be done in a single location at one of three delays. The virtual environment and location cues were effective for prospective memory, and performance was unaffected by delay. For Experiment 2, each trial involved two prospective memory tasks, given in either one or two instruction locations, and to be done in either one or two store locations. There was improved performance when people received instructions from two locations and did both tasks in one location relative to other combinations. This demonstrates that location-based event structure influences how well people perform on prospective memory tasks.

  17. Location-based Web Search

    NASA Astrophysics Data System (ADS)

    Ahlers, Dirk; Boll, Susanne

    In recent years, the relation of Web information to a physical location has gained much attention. However, Web content today often carries only an implicit relation to a location. In this chapter, we present a novel location-based search engine that automatically derives spatial context from unstructured Web resources and allows for location-based search: our focused crawler applies heuristics to crawl and analyze Web pages that have a high probability of carrying a spatial relation to a certain region or place; the location extractor identifies the actual location information from the pages; our indexer assigns a geo-context to the pages and makes them available for a later spatial Web search. We illustrate the usage of our spatial Web search for location-based applications that provide information not only right-in-time but also right-on-the-spot.

  18. FOOD - SHUTTLE

    NASA Image and Video Library

    1982-02-01

    S82-26423 (January 1982) --- This is a close-up view of the rehydration unit to be used in meal preparation on operational space shuttle flights. The unit is located on the middeck of the space shuttles in the NASA fleet. Note the part of the food tray in upper right corner. Its six compartments (not all pictured) are used in space shuttle meal preparation and consumption. Photo credit: NASA

  19. STS-38 Pilot Culbertson removes film from an OV-104 middeck stowage locker

    NASA Technical Reports Server (NTRS)

    1990-01-01

    STS-38 Pilot Frank L. Culbertson removes photographic film from stowage locker MF43E located on the middeck of Atlantis, Orbiter Vehicle (OV) 104. Additional items fastened to the forward lockers include a doll, meal tray assemblies, a SONY Walkman, a camera lens, and a Department of Air Force insignia (decal). The crew escape pole (CEP) extends over Culbertson's head and the open airlock hatch appears behind him.

  20. STS-26 crew stowage review in Bldg 9A crew compartment trainer (CCT)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers rehearse for their upcoming mission in the crew compartment trainer (CCT) located in the JSC Mockup and Integration Laboratory Bldg 9A. Standing on the CCT middeck, Pilot Richard O. Covey hands a snack package to Mission Specialist (MS) John M. Lounge (back to the camera). Covey selected the snack from the meal tray assemblies (foodtrays) mounted on the forward middeck lockers.

  1. Micrometeoroids and debris on LDEF comparison with MIR data

    NASA Technical Reports Server (NTRS)

    Mandeville, Jean-Claude; Berthoud, Lucinda

    1995-01-01

    Part of the LDEF tray allocated to French experiments (FRECOPA) has been devoted to the study of dust particles. The tray was located on the face of LDEF directly opposed to the velocity vector. Crater size distributions have made possible the evaluation of the incident microparticle flux in the near-Earth environment. Comparisons are made with measurements obtained on the other faces of LDEF (tray clamps), on the leading edge (MAP) and with results of a similar experiment flown on the MIR space station. The geometry of impact craters, depth in particular, provides useful information on the nature of impacting particles and the correlation of geometry with the chemical analysis of projectile remnants inside craters make possible a discrimination between meteoroids and orbital debris. Emphasis has been laid on the size distribution of small craters in order to assess a cut-off in the distribution of particles in LEO. Special attention has been paid to the phenomenon of secondary impacts. A comparison of flight data with current models of meteoroids and space debris shows a fair agreement for LDEF, except for the smaller particles: the possible contribution of orbital debris in GTO orbits to the LDEF trailing edge flux is discussed. For MIR, flight results show differences with current modeling: the possible enhancement of orbital debris could be due to the contaminating presence of a permanently manned space station.

  2. A recirculating hydroponic system for studying peanut (Arachis hypogaea L.)

    NASA Technical Reports Server (NTRS)

    Mackowiak, C. L.; Wheeler, R. M.; Stutte, G. W.; Yorio, N. C.; Ruffe, L. M.; Sager, J. C. (Principal Investigator)

    1998-01-01

    Peanut (Arachis hypogaea L.) plants were grown hydroponically, using continuously recirculating nutrient solution. Two culture tray designs were tested; one tray design used only nutrient solution, while the other used a sphagnum-filled pod development compartment just beneath the cover and above the nutrient solution. Both trays were fitted with slotted covers to allow developing gynophores to reach the root zone. Peanut seed yields averaged 350 gm-2 dry mass, regardless of tray design, suggesting that substrate is not required for hydroponic peanut production.

  3. In vivo Study of the Accuracy of Dual-arch Impressions.

    PubMed

    de Lima, Luciana Martinelli Santayana; Borges, Gilberto Antonio; Junior, Luiz Henrique Burnett; Spohr, Ana Maria

    2014-06-01

    This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a pattern. Ten impressions were made with each tray and impression material. The impressions were poured with Type IV gypsum. The width and height of the pattern and casts were measured in a profile projector (Nikon). The results were submitted to Student's t-test for one sample (α = 0.05). For the width distance, the plastic dual-arch trays with vinyl polysiloxane (4.513 mm) and with polyether (4.531 mm) were statistically wider than the pattern (4.489 mm). The metal dual-arch tray with vinyl polysiloxane (4.504 mm) and with polyether (4.500 mm) did not differ statistically from the pattern. For the height distance, only the metal dual-arch tray with polyether (2.253 mm) differed statistically from the pattern (2.310 mm). The metal dual-arch tray with vinyl polysiloxane, in the putty/wash viscosities, reproduced casts with less distortion in comparison with the same technique with the plastic dual-arch tray. The plastic or metal dual-arch trays with polyether reproduced cast with greater distortion. How to cite the article: Santayana de Lima LM, Borges GA, Burnett LH Jr, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6(3):50-5.

  4. Preliminary impression techniques for microstomia patients

    PubMed Central

    Kumar, K. Aswini; Bhat, Vinaya; Nair, K. Chandrasekheran; Suresh, Reshma

    2016-01-01

    The Prosthetic rehabilitation of microstomia patients presents difficulties at all the stages. The difficulty starts with the preliminary impression making. This is due to the tongue rigidity and the decreased oral opening. A maximum oral opening which is smaller than the size of the tray can make prosthetic treatment challenging. Due to the restricted mouth opening, insertion and removal of the impression trays is extremely cumbersome and various modifications of the trays have been used in the past. Among these are the flexible trays and the sectional trays used with different modes of reassembling the segments extra orally after the impression is made. This article reviews the literature published from 1971 to 2015 concerning preliminary impression techniques used in making impressions for patients with microstomia based on various tray designs. An electronic search was performed across three databases (PubMed, Science Direct and Google Scolar) for relevant citations. The keywords/combinations used for the search were microstomia, limited/constricted/restricted mouth opening/oral access, trismus, sectional trays, impressions and prosthetic/prosthodontic rehabilitation. The search was limited to papers written in English which resulted in a total of 45 related articles of which 17 articles were included for discussion of this review. PMID:27621540

  5. The LMOP Locator

    EPA Pesticide Factsheets

    This page contains the LMOP Locator, a tool that allows a user to geographically search for facilities that can potentially utilize LFG, or for landfills located near a facility that is interested in utilizing LFG.

  6. Location | FNLCR Staging

    Cancer.gov

    The Frederick National Laboratory for Cancer Research campus is located 50 miles northwest of Washington, D.C., and 50 miles west of Baltimore, Maryland, in Frederick, Maryland. Satellite locations include leased and government facilities extending s

  7. Bacteria holding times for fecal coliform by mFC agar method and total coliform and Escherichia coli by Colilert®-18 Quanti-Tray® method

    USGS Publications Warehouse

    Aulenbach, Brent T.

    2010-01-01

    Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.

  8. Macromolecular crystal growing system

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S. (Inventor); Herren, Blair J. (Inventor); Carter, Daniel C. (Inventor); Yost, Vaughn H. (Inventor); Bugg, Charles E. (Inventor); Delucas, Lawrence J. (Inventor); Suddath, Fred L. (Inventor)

    1991-01-01

    A macromolecular crystal growing system especially designed for growing crystals in the low gravity of space as well as the gravity of earth includes at least one tray assembly, a carrier assembly which receives the tray, and a refrigeration-incubation module in which the carrier assembly is received. The tray assembly includes a plurality of sealed chambers with a plastic syringe and a plug means for the double tip of the syringe provided therein. Ganging mechanisms operate the syringes and plugs simultaneously in a precise and smooth operation. Preferably, the tray assemblies are mounted on ball bearing slides for smooth operation in inserting and removing the tray assemblies into the carrier assembly. The plugging mechanism also includes a loading control mechanism. A mechanism for leaving a syringe unplugged is also provided.

  9. DIORAMA Location Type User's Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terry, James Russell

    2015-01-29

    The purpose of this report is to present the current design and implementation of the DIORAMA location type object (LocationType) and to provide examples and use cases. The LocationType object is included in the diorama-app package in the diorama::types namespace. Abstractly, the object is intended to capture the full time history of the location of an object or reference point. For example, a location may be speci ed as a near-Earth orbit in terms of a two-line element set, in which case the location type is capable of propagating the orbit both forward and backward in time to provide amore » location for any given time. Alternatively, the location may be speci ed as a xed set of geodetic coordinates (latitude, longitude, and altitude), in which case the geodetic location of the object is expected to remain constant for all time. From an implementation perspective, the location type is de ned as a union of multiple independent objects defi ned in the DIORAMA tle library. Types presently included in the union are listed and described in subsections below, and all conversions or transformation between these location types are handled by utilities provided by the tle library with the exception of the \\special-values" location type.« less

  10. Growing Large Quantities of Containerized Seedlings

    Treesearch

    Tim Pittman

    2002-01-01

    The sowing of large quantities of longleaf pine (Pinus palustris Mill.) seed into trays depends on the quality of the seed and the timing of seed sowing. This can be accomplished with mechanization. Seed quality is accomplished by using a gravity table. Tray filling can be accomplished by using a ribbon-type soil mixer and an automated tray-filling...

  11. Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques

    PubMed Central

    Alikhasi, Marzieh; Siadat, Hakimeh; Kharazifard, Mohammad Javad

    2015-01-01

    Objectives: The purpose of this study was to compare the accuracy of implant position transfer and surface detail reproduction using two impression techniques and materials. Materials and Methods: A metal model with two implants and three grooves of 0.25, 0.50 and 0.75 mm in depth on the flat superior surface of a die was fabricated. Ten regular-body polyether (PE) and 10 regular-body polyvinyl siloxane (PVS) impressions with square and conical transfer copings using open tray and closed tray techniques were made for each group. Impressions were poured with type IV stone, and linear and angular displacements of the replica heads were evaluated using a coordinate measuring machine (CMM). Also, accurate reproduction of the grooves was evaluated by a video measuring machine (VMM). These measurements were compared with the measurements calculated on the reference model that served as control, and the data were analyzed with two-way ANOVA and t-test at P= 0.05. Results: There was less linear displacement for PVS and less angular displacement for PE in closed-tray technique, and less linear displacement for PE in open tray technique (P<0.001). Also, the open tray technique showed less angular displacement with the use of PVS impression material. Detail reproduction accuracy was the same in all the groups (P>0.05). Conclusion: The open tray technique was more accurate using PE, and also both closed tray and open tray techniques had acceptable results with the use of PVS. The choice of impression material and technique made no significant difference in surface detail reproduction. PMID:27252761

  12. STS-26 crew stowage review in Bldg 9A crew compartment trainer (CCT)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-26 Discovery, Orbiter Vehicle (OV) 103, crewmembers rehearse for their upcoming mission in the crew compartment trainer (CCT) located in the JSC Mockup and Integration Laboratory Bldg 9A. Standing on the CCT middeck, the crewmembers have just selected a snack from the meal tray assembly (foodtray) mounted on the forward middeck lockers. Left to right are Mission Specialist (MS) John M. Lounge, Commander Frederick H. Hauck, and MS George D. Nelson.

  13. The effects of packaging method (vacuum pouch vs. plastic tray) on spoilage in a cook-chill pork-based dish kept under refrigeration.

    PubMed

    Díaz, Pedro; Garrido, María Dolores; Bañón, Sancho

    2010-03-01

    The effects of two packaging methods on the spoilage of a cook-chill pork-based dish kept under refrigeration were studied. Raw pork cuts and pre-cooked tomato sauce were packed under vacuum "sous vide" in polyamide-polypropylene pouches (SV) or into translucent polypropylene trays under modified atmosphere (80% N(2)+20% CO(2)) and sealed with a top film (PT). Samples were cooked inside the pack at an oven temperature/time of 70 degrees C/7h, chilled at 3 degrees C and stored at 2 degrees C for up to 90days. Microbial (psychrotrophs, lactic-acid bacteria, Enterobacteriaceae, moulds and yeasts), physical-chemical (pH, water activity and total acidity) and sensory (colour, odour, flavour, texture and acceptance) parameters were determined. Heat penetration was faster in SV (2 degrees C/min) than in PT (1 degrees C/min) (core temperature). Both packaging methods were equally effective in protecting against microbial spoilage for 90 day at 2 degrees C. Minor counts were only detected for lactic-acid bacteria and anaerobic psychrotrophs in SV. No Enterobacteriaceae growth was found. Slight differences between SV and PT in pH and total acidity were observed. SV and PT had similar effects on the sensory preservation of the dishes. A gradual loss of acceptance of the cooked pork and tomato sauce was observed. Rancid flavour in PT and warmed-over-flavour in SV were noted in the final stages of storage. According to acceptance scores, the shelf-life of both SV and PT was 56 days at 2 degrees C. Both packaging methods can be used to manufacture sous vide meat-based dishes subsequently stored under refrigeration for catering use. Copyright 2009 Elsevier Ltd. All rights reserved.

  14. Privacy-Preserving Location-Based Query Using Location Indexes and Parallel Searching in Distributed Networks

    PubMed Central

    Liu, Lei; Zhao, Jing

    2014-01-01

    An efficient location-based query algorithm of protecting the privacy of the user in the distributed networks is given. This algorithm utilizes the location indexes of the users and multiple parallel threads to search and select quickly all the candidate anonymous sets with more users and their location information with more uniform distribution to accelerate the execution of the temporal-spatial anonymous operations, and it allows the users to configure their custom-made privacy-preserving location query requests. The simulated experiment results show that the proposed algorithm can offer simultaneously the location query services for more users and improve the performance of the anonymous server and satisfy the anonymous location requests of the users. PMID:24790579

  15. Privacy-preserving location-based query using location indexes and parallel searching in distributed networks.

    PubMed

    Zhong, Cheng; Liu, Lei; Zhao, Jing

    2014-01-01

    An efficient location-based query algorithm of protecting the privacy of the user in the distributed networks is given. This algorithm utilizes the location indexes of the users and multiple parallel threads to search and select quickly all the candidate anonymous sets with more users and their location information with more uniform distribution to accelerate the execution of the temporal-spatial anonymous operations, and it allows the users to configure their custom-made privacy-preserving location query requests. The simulated experiment results show that the proposed algorithm can offer simultaneously the location query services for more users and improve the performance of the anonymous server and satisfy the anonymous location requests of the users.

  16. The Role of Experience in Location Estimation: Target Distributions Shift Location Memory Biases

    ERIC Educational Resources Information Center

    Lipinski, John; Simmering, Vanessa R.; Johnson, Jeffrey S.; Spencer, John P.

    2010-01-01

    Research based on the Category Adjustment model concluded that the spatial distribution of target locations does not influence location estimation responses [Huttenlocher, J., Hedges, L., Corrigan, B., & Crawford, L. E. (2004). Spatial categories and the estimation of location. "Cognition, 93", 75-97]. This conflicts with earlier results showing…

  17. Impact-Locator Sensor Panels

    NASA Technical Reports Server (NTRS)

    Christiansen, Eric L.; Byers, Terry; Gibbons, Frank

    2008-01-01

    Electronic sensor systems for detecting and locating impacts of rapidly moving particles on spacecraft have been invented. Systems of this type could also be useful on Earth in settings in which the occurrence of impacts and/or the locations of impacts are not immediately obvious and there are requirements to detect and quickly locate impacts to prevent or minimize damage.

  18. Importance of analytically verifying chemical treatments

    USGS Publications Warehouse

    Rach, J.J.; Gaikowski, M.P.; Olson, J.J.

    1997-01-01

    Hydrogen peroxide is considered a low regulatory priority compound by the U.S. Food and Drug Administration. It is used to control fungal infections on fish eggs. We studied the treatment profiles of hydrogen peroxide in Heath, McDonald egg jar, and Clark-Williamson incubators during treatments intended to deliver an effective regimen of at least 500 ??L hydrogen peroxide/L (i.e., treatments of 500 and 1,000 ??L/L) for 15 min. Hydrogen peroxide concentrations decreased with increasing distance from the influent water in both Heath and Clark-Williamson incubators. The top treatment tray (tray 2) of the Heath incubator received more than 90% of the intended regimen during the 500 ??L/L treatment, whereas at 1,000 ??L/L, all trays had hydrogen peroxide concentrations at or above 500 ??L/L for 15 min. None of the compartments in the Clark-Williamson incubator received the intended therapeutic regimen when treated at 500 ??L/L. The McDonald egg jar system distributed the intended concentration for the designated treatment period in all jars, except those located directly below the influent water. Our results indicate that dilution of therapeutants applied through certain egg incubation systems significantly decreases the efficacy of treatments and may render them ineffective. The dilution characteristics of egg incubation systems should be assessed in order to ensure proper delivery of all intended chemical concentrations and exposure regimens. Suggestions for maintaining the minimum effective concentrations in evaluated incubators are included.

  19. Privacy-Preserving Location-Based Services

    ERIC Educational Resources Information Center

    Chow, Chi Yin

    2010-01-01

    Location-based services (LBS for short) providers require users' current locations to answer their location-based queries, e.g., range and nearest-neighbor queries. Revealing personal location information to potentially untrusted service providers could create privacy risks for users. To this end, our objective is to design a privacy-preserving…

  20. Hance_WFSR flasher locations

    EPA Pesticide Factsheets

    This entry contains two files. The first file, Hance_WFSR Flasher locations.xlxs, contains information describing the location of installed landmark 'flashers' consisting of 2 square aluminum metal tags. Each tag was inscribed with a number to aid field personnel in the identification of landmark location within the West Fork Smith River watershed in southern coastal Oregon. These landmarks were used to calculate stream distances between points in the watershed, including distances between tagging locations and detection events for tagged fish. A second file, named Hance_fish_detection_data1.xlxs contains information on the detection of tagged fish within the West Fork Smith River stream network. The file includes both the location where the fish were tagged and where they were subsequently detected. Together with the information in the WFSR flasher location dataset, these data allow estimation of the minimum distances and directions moved by juvenile coho salmon during the fall transition period.A map locator is provided in Figure 1 in the accompanying manuscript: Dalton J. Hance, Lisa M. Ganio, Kelly M. Burnett & Joseph L. Ebersole (2016) Basin-Scale Variation in the Spatial Pattern of Fall Movement of Juvenile Coho Salmon in the West Fork Smith River, Oregon, Transactions of the American Fisheries Society, 145:5, 1018-1034, DOI: 10.1080/00028487.2016.1194892This dataset is associated with the following publication:Hance, D.J., L.M. Ganio, K.M. Burnett, an

  1. Eggsactly How Many?

    ERIC Educational Resources Information Center

    Zaferos, Melanie

    2016-01-01

    This investigation presents students with the challenge of determining the total number of eggs in a photograph of a stack of egg trays. The perspective of the photograph does not allow students to count all the individual eggs in the top tray but does allow them to see the number of eggs in one row and one column of the top tray. During this…

  2. Automatic vehicle location system

    NASA Technical Reports Server (NTRS)

    Hansen, G. R., Jr. (Inventor)

    1973-01-01

    An automatic vehicle detection system is disclosed, in which each vehicle whose location is to be detected carries active means which interact with passive elements at each location to be identified. The passive elements comprise a plurality of passive loops arranged in a sequence along the travel direction. Each of the loops is tuned to a chosen frequency so that the sequence of the frequencies defines the location code. As the vehicle traverses the sequence of the loops as it passes over each loop, signals only at the frequency of the loop being passed over are coupled from a vehicle transmitter to a vehicle receiver. The frequencies of the received signals in the receiver produce outputs which together represent a code of the traversed location. The code location is defined by a painted pattern which reflects light to a vehicle carried detector whose output is used to derive the code defined by the pattern.

  3. Object locating system

    DOEpatents

    Novak, James L.; Petterson, Ben

    1998-06-09

    A sensing system locates an object by sensing the object's effect on electric fields. The object's effect on the mutual capacitance of electrode pairs varies according to the distance between the object and the electrodes. A single electrode pair can sense the distance from the object to the electrodes. Multiple electrode pairs can more precisely locate the object in one or more dimensions.

  4. Differences in the validity of a visual estimation method for determining patients' meal intake between various meal types and supplied food items.

    PubMed

    Kawasaki, Yui; Akamatsu, Rie; Tamaura, Yuki; Sakai, Masashi; Fujiwara, Keiko; Tsutsuura, Satomi

    2018-02-12

    The aim of this study was to examine differences in the validity of a visual estimation method for determining patients' meal intake between various meal types and supplied food items in hospitals and to find factors influencing the validity of a visual estimation method. There are two procedures by which we obtained the information on dietary intake of the patients in these hospitals. These are both by visual assessment from the meal trays at the time of their clearing, by the attending nursing staff and by weighing conducted by researchers. The following criteria are set for the target trays: A) standard or therapeutic meals, which are monitored by a doctor, for energy and/or protein and/or sodium; B) regular, bite-sized, minced and pureed meal texture, and C) half-portion meals. Visual assessment results were tested for their validity by comparing with the corresponding results of weighing. Differences between these two methods indicated the estimated and absolute values of nutrient intake. A total of 255 (76.1%) trays were included in the analysis out of the 335 possible trays and the results indicated that the energy consumption estimates by visual or weighing procedures are not significantly different (412 ± 173 kcal, p = 0.15). However, the mean protein consumption was significantly different (16.3 ± 6.7 g/tray, p < 0.01) between the two procedures. Compared with standard meals (38 ± 45 kcal, 1.9 ± 2.5 g/tray), raters significantly misestimated the energy and protein intake of half-portion meals (78 ± 65 kcal, 2.8 ± 2.2 g/tray, p = 0.01) but accurately estimated the protein intake of protein controlled meals (0.5 ± 0.6 g/tray, p = 0.03). Trays adding supplied food items were significantly misestimated for energy intake (66 ± 58 kcal/tray) compared to trays with no additions (32 ± 39 kcal/tray, p < 0.01). Moreover, the results of multivariable analysis demonstrated that supplied food items were significantly

  5. Recolonization of gravel habitats on Georges Bank (northwest Atlantic)

    USGS Publications Warehouse

    Collie, Jeremy S.; Hermsen, Jerome M.; Valentine, Page C.

    2009-01-01

    Gravel habitats on continental shelves around the world support productive fisheries but are also vulnerable to disturbance from bottom fishing. We conducted a 2-year in situ experiment to measure the rate of colonization of a gravel habitat on northern Georges Bank in an area closed to fishing (Closed Area II) since December 1994. Three large (0.25 m2) sediment trays containing defaunated pebble gravel were deployed at a study site (47 m water depth) in July 1997 and recovered in June 1999. The undersides of the tray lids positioned 56 cm above the trays served as settlement panels over the same time period. We observed rapid colonization of the gravel substrate (56 species) and the settlement panels (35 species), indicating that colonization of gravel in this region is not limited by the supply of colonists. The species composition of the taxa found in the trays was broadly similar to that we collected over a 10-year period (1994-2004) in dredge samples from gravel sediments at the same site. The increase in abundance of animals in the gravel colonization trays was rapid and reached a level in 2 years that took 4.5 years to achieve in the surrounding gravel sediments once fishing had stopped, based on data from dredge sampling at this site. The increase in biomass of animals found in the sediment trays paralleled the trend of biomass increase observed in dredge samples over the same period (1997-1999) but was lower in value. These data suggest that after rapid initial increase in abundance of organisms, succession proceeded by increasing individual body size. A comparison of settlement panel and tray faunas revealed that the mean biomass of structure-forming epifauna (sponges, bryozoans, anemones, hydroids, colonial tube worms) on the panels was 8 times that found on the trays. Structure-forming taxa constituted 29% of the mean biomass of the panel fauna but only 5.5% of the tray fauna. By contrast, the mean biomass of scavengers (crabs, echinoderms, nudibranchs

  6. Recolonization of gravel habitats on Georges Bank (northwest Atlantic)

    NASA Astrophysics Data System (ADS)

    Collie, Jeremy S.; Hermsen, Jerome M.; Valentine, Page C.

    2009-09-01

    Gravel habitats on continental shelves around the world support productive fisheries but are also vulnerable to disturbance from bottom fishing. We conducted a 2-year in situ experiment to measure the rate of colonization of a gravel habitat on northern Georges Bank in an area closed to fishing (Closed Area II) since December 1994. Three large (0.25 m 2) sediment trays containing defaunated pebble gravel were deployed at a study site (47 m water depth) in July 1997 and recovered in June 1999. The undersides of the tray lids positioned 56 cm above the trays served as settlement panels over the same time period. We observed rapid colonization of the gravel substrate (56 species) and the settlement panels (35 species), indicating that colonization of gravel in this region is not limited by the supply of colonists. The species composition of the taxa found in the trays was broadly similar to that we collected over a 10-year period (1994-2004) in dredge samples from gravel sediments at the same site. The increase in abundance of animals in the gravel colonization trays was rapid and reached a level in 2 years that took 4.5 years to achieve in the surrounding gravel sediments once fishing had stopped, based on data from dredge sampling at this site. The increase in biomass of animals found in the sediment trays paralleled the trend of biomass increase observed in dredge samples over the same period (1997-1999) but was lower in value. These data suggest that after rapid initial increase in abundance of organisms, succession proceeded by increasing individual body size. A comparison of settlement panel and tray faunas revealed that the mean biomass of structure-forming epifauna (sponges, bryozoans, anemones, hydroids, colonial tube worms) on the panels was 8 times that found on the trays. Structure-forming taxa constituted 29% of the mean biomass of the panel fauna but only 5.5% of the tray fauna. By contrast, the mean biomass of scavengers (crabs, echinoderms, nudibranchs

  7. Object locating system

    DOEpatents

    Novak, J.L.; Petterson, B.

    1998-06-09

    A sensing system locates an object by sensing the object`s effect on electric fields. The object`s effect on the mutual capacitance of electrode pairs varies according to the distance between the object and the electrodes. A single electrode pair can sense the distance from the object to the electrodes. Multiple electrode pairs can more precisely locate the object in one or more dimensions. 12 figs.

  8. Locating Continuing Education Programs.

    ERIC Educational Resources Information Center

    Mason, Robert C.

    1986-01-01

    Emphasizes program location as an important component of the marketing plan for continuing education. Also discusses relations among program location and quality, costs, supportive services, and economies of scale. (CH)

  9. Location of colorectal cancer: colonoscopy versus surgery. Yield of colonoscopy in predicting actual location.

    PubMed

    Blum-Guzman, Juan Pablo; Wanderley de Melo, Silvio

    2017-07-01

     Recent studies suggest that differences in biological characteristics and risk factors across cancer site within the colon and rectum may translate to differences in survival. It can be challenging at times to determine the precise anatomical location of a lesion with a luminal view during colonoscopy. The aim of this study is to determine if there is a significant difference between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative and pathology reports after colon surgery.  A single-center retrospective analysis of colonoscopies of patient with reported colonic masses from January 2005 to April 2014 (n = 380) was carried. Assessed data included demography, operative and pathology reports. Findings were compared: between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative reports or pathology samples.  We identified 380 colonic masses, 158 were confirmed adenocarcinomas. Of these 123 underwent surgical resection, 27 had to be excluded since no specific location was reported on their operative or pathology report. An absolute difference between endoscopic and surgical location was found in 32 cases (33 %). Of these, 22 (23 %) differed by 1 colonic segment, 8 (8 %) differed by 2 colonic segments and 2 (2 %) differed by 3 colonic segments.  There is a significant difference between the location of colorectal cancers reported by gastroenterologists during endoscopy and the actual anatomical location noted on operative or pathology reports after colon surgery. Endoscopic tattooing should be used when faced with any luminal lesions of interest.

  10. LLNL Location and Detection Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myers, S C; Harris, D B; Anderson, M L

    2003-07-16

    We present two LLNL research projects in the topical areas of location and detection. The first project assesses epicenter accuracy using a multiple-event location algorithm, and the second project employs waveform subspace Correlation to detect and identify events at Fennoscandian mines. Accurately located seismic events are the bases of location calibration. A well-characterized set of calibration events enables new Earth model development, empirical calibration, and validation of models. In a recent study, Bondar et al. (2003) develop network coverage criteria for assessing the accuracy of event locations that are determined using single-event, linearized inversion methods. These criteria are conservative andmore » are meant for application to large bulletins where emphasis is on catalog completeness and any given event location may be improved through detailed analysis or application of advanced algorithms. Relative event location techniques are touted as advancements that may improve absolute location accuracy by (1) ensuring an internally consistent dataset, (2) constraining a subset of events to known locations, and (3) taking advantage of station and event correlation structure. Here we present the preliminary phase of this work in which we use Nevada Test Site (NTS) nuclear explosions, with known locations, to test the effect of travel-time model accuracy on relative location accuracy. Like previous studies, we find that the reference velocity-model and relative-location accuracy are highly correlated. We also find that metrics based on travel-time residual of relocated events are not a reliable for assessing either velocity-model or relative-location accuracy. In the topical area of detection, we develop specialized correlation (subspace) detectors for the principal mines surrounding the ARCES station located in the European Arctic. Our objective is to provide efficient screens for explosions occurring in the mines of the Kola Peninsula (Kovdor

  11. Water reactive hydrogen fuel cell power system

    DOEpatents

    Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

    2014-01-21

    A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

  12. Water reactive hydrogen fuel cell power system

    DOEpatents

    Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

    2014-11-25

    A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

  13. Contact structure for use in catalytic distillation

    DOEpatents

    Jones, Jr., Edward M.

    1984-01-01

    A method for conducting catalytic chemical reactions and fractionation of the reaction mixture comprising feeding reactants into a distillation column reactor contracting said reactant in liquid phase with a fixed bed catalyst in the form of a contact catalyst structure consisting of closed porous containers containing the catatlyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column.

  14. Spatial negative priming: Location or response?

    PubMed

    Neill, W Trammell; Kleinsmith, Abigail L

    2016-11-01

    In tasks requiring a response to the location of a target stimulus (for example, reaching), responses often are slower to a location that was recently occupied by an irrelevant distractor stimulus. In most demonstrations of this "spatial negative priming" (SNP), there is a 1-to-1 correspondence between possible stimulus locations and possible responses. As such, it is ambiguous whether the effect is due to a location-specific processing delay or to inhibition of a response. In the present experiment, subjects were required to press a key corresponding to the ordinal position of a target O in one of four locations, ignoring a distractor X appearing in another location. Location markers were widely or narrowly spaced, such that the inner two locations of wide displays corresponded to the outer two locations of narrow displays (hence, requiring different responses). SNP occurred when a target appeared at the location of a recent distractor, regardless of whether the response was associated with the distractor. In contrast, no SNP occurred for a target sharing the same response as a distractor, but in a different location. The results strongly support a location-specific, rather than response-specific, locus of SNP.

  15. LOCAT - A Data Retrieval Program.

    DTIC Science & Technology

    1984-12-01

    onoitode of scified location - P C RADIUS - maximum distance between specified location and C file locationsC . ’ CONNON /LOCN/ LOCLAT, LOCLNG, RADIUS...rrr’, ,r:.- r -’ - r- rJ Z. . . , . -.-. - - - - - - -- , -• .. . . FILMED 8-85 DTIC .-. ... , ,- . . . . ...: .--. :,.:. ..-..-- ,-, .-..-...

  16. A field experimental study on recolonization and succession of subtidal macrobenthic community in sediment contaminated with industrial wastes.

    PubMed

    Lu, L; Wu, R S S

    2007-02-01

    A field experiment was carried out in Hong Kong to study the patterns of recolonization and succession of subtidal macrobenthos in defaunated sediment contaminated with industrial wastes and to determine the time required for benthic recovery in the industrial-contaminated sediment. A total of 50 species was found with an average of 172 animals/tray and 24 species/tray recorded one month after deployment. Initial colonizers were predominantly polychaetes (96 animals/tray, accounting for 55.7%) and gastropods (47 animals/tray, accounting for 27.2%). Abundance of macrobenthos increased quickly to a peak (505 animals/tray) after four months, declined afterwards, and increased again till the end of the experiment. Species number peaked (57 species/tray) in the same month as abundance did, and gradually declined thereafter. Abundance, species number and diversity were significantly lower in the industrial-contaminated sediment as compared to the controls during the early successional stages, indicating the harmful effects of industrial wastes on recolonization and succession of macrobenthos. Although no significant differences in community parameters between the industrial-contaminated and the control sediments were found after eleven months, significant difference in species composition still existed after fourteen months, showing a relatively long-term impact of industrial wastes on macrobenthic community structure.

  17. Pilot Overmyer looks over food selections and experiments with beverage

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Pilot Overmyer, using beverage container and drinking straw secured in meal tray assembly (ASSY), experiments with microgravity chararcteristics of liquid on middeck in front of forward lockers. Overmyer also looks over packages of food attached to middeck lockers in meal tray assemblies. Carry-on food warmer appears overhead and other meal tray assemblies, personal hygiene mirror assy, personal hygiene kit, and portrait of G.W.S. Abbey, JSC's Director of Flight Operations, appear on lockers.

  18. Arousal-Enhanced Location Memory for Pictures

    PubMed Central

    Mather, Mara; Nesmith, Kathryn

    2008-01-01

    Four experiments revealed arousal-enhanced location memory for pictures. After an incidental encoding task, participants were more likely to remember the locations of positive and negative arousing pictures than the locations of non-arousing pictures, indicating better binding of location to picture. This arousal-enhanced binding effect did not have a cost for the binding of nearby pictures to their locations. Thus, arousal can enhance binding of an arousing picture’s content to its location without interfering with picture-location binding for nearby pictures. In addition, arousal-enhanced picture-location memory binding is not just a side effect of enhanced memory for the picture itself, as it occurs both when recognition memory is good and when it is poor. PMID:19190722

  19. Spring loaded locator pin assembly

    DOEpatents

    Groll, Todd A.; White, James P.

    1998-01-01

    This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece.

  20. Dental bleaching on teeth submitted to enamel microabrasion 30 years ago-a case report of patients' compliance during bleaching treatment.

    PubMed

    Sundfeld, Daniel; Pavani, Caio Cesar; Schott, Timm Cornelius; Machado, Lucas Silveira; Pini, Núbia Inocêncya Pavesi; Bertoz, André Pinheiro de Magalhães; Sundfeld, Renato Herman

    2018-04-20

    The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment.

  1. Design of a TDOA location engine and development of a location system based on chirp spread spectrum.

    PubMed

    Wang, Rui-Rong; Yu, Xiao-Qing; Zheng, Shu-Wang; Ye, Yang

    2016-01-01

    Location based services (LBS) provided by wireless sensor networks have garnered a great deal of attention from researchers and developers in recent years. Chirp spread spectrum (CSS) signaling formatting with time difference of arrival (TDOA) ranging technology is an effective LBS technique in regards to positioning accuracy, cost, and power consumption. The design and implementation of the location engine and location management based on TDOA location algorithms were the focus of this study; as the core of the system, the location engine was designed as a series of location algorithms and smoothing algorithms. To enhance the location accuracy, a Kalman filter algorithm and moving weighted average technique were respectively applied to smooth the TDOA range measurements and location results, which are calculated by the cooperation of a Kalman TDOA algorithm and a Taylor TDOA algorithm. The location management server, the information center of the system, was designed with Data Server and Mclient. To evaluate the performance of the location algorithms and the stability of the system software, we used a Nanotron nanoLOC Development Kit 3.0 to conduct indoor and outdoor location experiments. The results indicated that the location system runs stably with high accuracy at absolute error below 0.6 m.

  2. Spring loaded locator pin assembly

    DOEpatents

    Groll, T.A.; White, J.P.

    1998-03-03

    This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece. 5 figs.

  3. Effects of long term space environment exposure on optical substrates and coatings (S0050-2)

    NASA Technical Reports Server (NTRS)

    Harvey, Keith; Mustico, Arthur; Vallimont, John

    1993-01-01

    Eastman Kodak Company included twelve substrate and coating samples on the Long Duration Exposure Facility (LDEF) structure. There were three Fused Silica and three Ultra Low Expansion (ULE) uncoated glass samples, two ULE samples with a high reflectance silver coating, two Fused Silica samples with an antireflectance coating, and two Fused silica samples with a solar rejection coating. A set of duplicate control samples was also manufactured and stored in a controlled environment for comparison purposes. Kodak's samples were included as a subset of the Georgia Institute of Technology tray, which was located on row 5-E, tray S0050-2. This placed the samples on the trailing edge of the structure, which protected them from the effects of atomic oxygen bombardment. An evaluation of the flight samples for effects from the 5 year mission showed that a contaminant was deposited on the samples, a micrometeoroid impact occurred on one of the samples, and the radiation darkening which was expected for the glass did not occur. The results are listed in more detail.

  4. Microgravity

    NASA Image and Video Library

    1988-10-24

    Mission Specialist George (Pinky) D. Nelson uses a 35 mm camera to photograph a protein crystal grown during the STS-26 Protein Crystal Growth (PCG-II-01) experiment. The protein crystal growth (PCG) carrier is shown deployed from the PCG Refrigerator/Incubator Mocule (R/IM) located in the middeck forward locker. The R/IM contained three Vapor Diffusion Apparatus (VDS) trays (one of which is shown). A total of sixty protein crystal samples were processed during the STS-26 mission.

  5. 7 CFR 1924.106 - Location.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Location. 1924.106 Section 1924.106 Agriculture... CONSTRUCTION AND REPAIR Planning and Performing Site Development Work § 1924.106 Location. (a) General. It is... will not finance development on locations that adversely affect properties which are listed or are...

  6. 77 FR 64834 - Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ... automatic fixed deluge water spray system installed over cable trays and open hatches. The deluge... installed over cable trays and open hatches. The deluge suppression system protecting safety- related cable...

  7. 46 CFR 108.493 - Location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location. 108.493 Section 108.493 Shipping COAST GUARD... Extinguishing Systems Hand Portable and Semiportable Fire Extinguishing Systems § 108.493 Location. (a) Each... this subpart and installed in the locations prescribed in the table. (b) Each portable and semi...

  8. Contact structure for use in catalytic distillation

    DOEpatents

    Jones, E.M. Jr.

    1984-03-27

    A method is described for conducting catalytic chemical reactions and fractionation of the reaction mixture comprising feeding reactants into a distillation column reactor, contracting said reactant in liquid phase with a fixed bed catalyst in the form of a contact catalyst structure consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column. 7 figs.

  9. Contact structure for use in catalytic distillation

    DOEpatents

    Jones, Jr., Edward M.

    1985-01-01

    A method and apparatus for conducting catalytic chemical reactions and fractionation of the reaction mixture, comprising and feeding reactants into a distillation column reactor contracting said reactant in a liquid phase with a fixed bed catalyst in the form of a contact catalyst structure, consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column.

  10. Contact structure for use in catalytic distillation

    DOEpatents

    Jones, E.M. Jr.

    1985-08-20

    A method and apparatus are disclosed for conducting catalytic chemical reactions and fractionation of the reaction mixture, comprising and feeding reactants into a distillation column reactor contracting said reactant in a liquid phase with a fixed bed catalyst in the form of a contact catalyst structure, consisting of closed porous containers containing the catalyst for the reaction and a clip means to hold and support said containers, which are disposed above, i.e., on the distillation trays in the tower. The trays have weir means to provide a liquid level on the trays to substantially cover the containers. In other words, the trays function in their ordinary manner with the addition thereto of the catalyst. The reaction mixture is concurrently fractionated in the column. 7 figs.

  11. Precision zero-home locator

    DOEpatents

    Stone, William J.

    1986-01-01

    A zero-home locator includes a fixed phototransistor switch and a moveable actuator including two symmetrical, opposed wedges, each wedge defining a point at which switching occurs. The zero-home location is the average of the positions of the points defined by the wedges.

  12. Precision zero-home locator

    DOEpatents

    Stone, W.J.

    1983-10-31

    A zero-home locator includes a fixed phototransistor switch and a moveable actuator including two symmetrical, opposed wedges, each wedge defining a point at which switching occurs. The zero-home location is the average of the positions of the points defined by the wedges.

  13. Sensors Locate Radio Interference

    NASA Technical Reports Server (NTRS)

    2009-01-01

    After receiving a NASA Small Business Innovation Research (SBIR) contract from Kennedy Space Center, Soneticom Inc., based in West Melbourne, Florida, created algorithms for time difference of arrival and radio interferometry, which it used in its Lynx Location System (LLS) to locate electromagnetic interference that can disrupt radio communications. Soneticom is collaborating with the Federal Aviation Administration (FAA) to install and test the LLS at its field test center in New Jersey in preparation for deploying the LLS at commercial airports. The software collects data from each sensor in order to compute the location of the interfering emitter.

  14. Alternative Fueling Station Locator - Android

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    The Alternative Fueling Station Locator app helps users locate fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. The users' current location or a custom location can be used to find the 20 closest stations within a 30-mile radius. View the stations on a map or see a list of stations ordered by distance from your location. Select your alternative fuel of choice and adjust the custom filters to fit your needs. Select a station from the map or list to view contact info and other details: address, phone number, and hours of operation; payment types accepted;more » public or private access; special services; compression (natural gas); vehicle size access (natural gas); number and types of chargers (electric); blends available (biodiesel); and blender pumps (ethanol) The app draws information from the U.S. Department of Energy's Alternative Fuels Data Center, which houses the most comprehensive, up-to-date database of alternative fueling stations in the United States. The database contains location information for more than 20,000 alternative fueling stations throughout the country.« less

  15. Location identifiers

    DOT National Transportation Integrated Search

    1997-01-30

    This order lists the location identifiers authorized by the Federal Aviation Administration, Department of the Navy, and Transport Canada. It lists United States airspace fixes and procedure codes. The order also includes guidelines for requesting id...

  16. 47 CFR 22.625 - Transmitter locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Transmitter locations. 22.625 Section 22.625... Paging and Radiotelephone Service Point-To-Multipoint Operation § 22.625 Transmitter locations. This... channels will occur. (1) Control transmitter locations. Control transmitter locations must be within 80...

  17. Location Privacy Protection on Social Networks

    NASA Astrophysics Data System (ADS)

    Zhan, Justin; Fang, Xing

    Location information is considered as private in many scenarios. Protecting location information on mobile ad-hoc networks has attracted much research in past years. However, location information protection on social networks has not been paid much attention. In this paper, we present a novel location privacy protection approach on the basis of user messages in social networks. Our approach grants flexibility to users by offering them multiple protecting options. To the best of our knowledge, this is the first attempt to protect social network users' location information via text messages. We propose five algorithms for location privacy protection on social networks.

  18. Evaluation of relocation of unionid mussels into artificial ponds

    USGS Publications Warehouse

    Newton, T.J.; Monroe, E.M.; Kenyon, R.; Gutreuter, S.; Welke, K.I.; Thiel, P.A.

    2001-01-01

    Relocation of unionid mussels into refuges (e.g., hatchery ponds) has been suggested as a management tool to protect these animals from the threat of zebra mussel (Dreissena polymorpha) invasion. To evaluate the efficacy of relocation, we experimentally relocated 768 mussels, representing 5 species (Leptodea fragilis, Obliquaria reflexa, Fusconaia flava, Amblema plicata, and Quadrula quadrula) into an earthen pond at a National Fish Hatchery or back into the river. In both locations, mussels were placed into 1 of 4 treatments (mesh bags, corrals, and buried or suspended substrate-filled trays). Mussels were examined annually for survival, growth (shell length and wet mass), and physiological condition (glycogen concentration in foot and mantle and tissue condition index) for 36 mo in the pond or 40 mo in the river. We observed significant differences in mortality rates between locations (mortality was 4 times greater in the pond than in the river), among treatments (lowest mortality in the suspended trays), and among species (lower mortality in the amblemines than lamp-silines). Overall survival in both locations averaged 80% the 1st year; survival in the pond decreased dramatically after that. Although length and weight varied between locations and over time, these changes were small, suggesting that their utility as short-term measures of well being in long-lived unionids is questionable. Mussels relocated to the pond were in poor physiological condition relative to those in the river, but the magnitude of these differences was small compared to the inherent variability in physiological condition of reference mussels. These data suggest that relocation of unionids into artificial ponds is a high-risk conservation strategy; alternatives such as introduction of infected host fish, identification of mussel beds at greatest risk from zebra mussels, and a critical, large-scale assessment of the factors contributing to their decline should be explored.

  19. Language and memory for object location.

    PubMed

    Gudde, Harmen B; Coventry, Kenny R; Engelhardt, Paul E

    2016-08-01

    In three experiments, we investigated the influence of two types of language on memory for object location: demonstratives (this, that) and possessives (my, your). Participants first read instructions containing demonstratives/possessives to place objects at different locations, and then had to recall those object locations (following object removal). Experiments 1 and 2 tested contrasting predictions of two possible accounts of language on object location memory: the Expectation Model (Coventry, Griffiths, & Hamilton, 2014) and the congruence account (Bonfiglioli, Finocchiaro, Gesierich, Rositani, & Vescovi, 2009). In Experiment 3, the role of attention allocation as a possible mechanism was investigated. Results across all three experiments show striking effects of language on object location memory, with the pattern of data supporting the Expectation Model. In this model, the expected location cued by language and the actual location are concatenated leading to (mis)memory for object location, consistent with models of predictive coding (Bar, 2009; Friston, 2003). Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  20. LDEF materials data analysis: Representative examples

    NASA Technical Reports Server (NTRS)

    Pippin, Gary; Crutcher, Russ

    1993-01-01

    Part of the philosophy which guided the examination of hardware from the Long Duration Exposure Facility (LDEF) was that materials present at multiple locations should have fairly high priority for investigation. Properties of such materials were characterized as a function of exposure conditions to obtain as much data as possible for predicting performance lifetimes. Results from examination of several materials from interior locations of LDEF, selected measurements on silverized teflon blanket specimens, and detailed measurements on the copper grounding strap from tray D11 are summarized. Visual observations of interior locations of LDEF made during deintegration at KSC showed apparent changes in particular specimens. This inspection lead to testing of selected nylon clamps, fiberglass shims, and heat shrink tubing from wire harness clamps, and visually discolored silver coated hex nuts.

  1. Surface Location In Scene Content Analysis

    NASA Astrophysics Data System (ADS)

    Hall, E. L.; Tio, J. B. K.; McPherson, C. A.; Hwang, J. J.

    1981-12-01

    The purpose of this paper is to describe techniques and algorithms for the location in three dimensions of planar and curved object surfaces using a computer vision approach. Stereo imaging techniques are demonstrated for planar object surface location using automatic segmentation, vertex location and relational table matching. For curved surfaces, the locations of corresponding 'points is very difficult. However, an example using a grid projection technique for the location of the surface of a curved cup is presented to illustrate a solution. This method consists of first obtaining the perspective transformation matrix from the images, then using these matrices to compute the three dimensional point locations of the grid points on the surface. These techniques may be used in object location for such applications as missile guidance, robotics, and medical diagnosis and treatment.

  2. 10 CFR 75.11 - Location information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Location information. 75.11 Section 75.11 Energy NUCLEAR... and Location Information § 75.11 Location information. (a) As required by the Additional Protocol, each applicant, licensee, or certificate holder shall submit location information to the Commission as...

  3. Determining Optimal College Locations

    ERIC Educational Resources Information Center

    Schofer, J. P.

    1975-01-01

    Location can be a critical determinant of the success of a college. Central Place Theory, as developed in geographic studies of population distribution patterns, can provide insights into the problem of evaluating college locations. In this way preferences of students can be balanced against economic, academic, and political considerations.…

  4. A Practical Recycling Project . . .

    ERIC Educational Resources Information Center

    Durant, Raymond H.; Mikuska, James M.

    1973-01-01

    Descirbes a school district's recycling program of aluminum lunch trays that are collected after their use. The trays are used as scrap metal in industrial education workshop and used for sand castings. (PS)

  5. 10 CFR 75.11 - Location information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to manage IAEA access to the location to protect health and safety or to protect classified... 10 Energy 2 2012-01-01 2012-01-01 false Location information. 75.11 Section 75.11 Energy NUCLEAR... and Location Information § 75.11 Location information. (a) As required by the Additional Protocol...

  6. 46 CFR 108.175 - Contiguous locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Contiguous locations. 108.175 Section 108.175 Shipping... EQUIPMENT Construction and Arrangement Classified Locations § 108.175 Contiguous locations. An enclosed space that has direct access to a Division 1 or Division 2 location is the same division as that...

  7. 43 CFR 3815.1 - Mineral locations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Mineral locations. 3815.1 Section 3815.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Stock Driveway Withdrawals § 3815.1 Mineral locations. Under authority of the provisions of the...

  8. 43 CFR 3815.1 - Mineral locations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Mineral locations. 3815.1 Section 3815.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Stock Driveway Withdrawals § 3815.1 Mineral locations. Under authority of the provisions of the...

  9. 43 CFR 3815.1 - Mineral locations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Mineral locations. 3815.1 Section 3815.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Stock Driveway Withdrawals § 3815.1 Mineral locations. Under authority of the provisions of the...

  10. 43 CFR 3815.1 - Mineral locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Mineral locations. 3815.1 Section 3815.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Stock Driveway Withdrawals § 3815.1 Mineral locations. Under authority of the provisions of the...

  11. Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

    PubMed

    Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad

    2015-01-01

    Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P < 0.05). In open tray technique, there was a significant difference in the rotation of analogs compared with the master model with both impression materials (P < 0.05). There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings.

  12. Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts

    PubMed Central

    Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad

    2015-01-01

    Background: Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Materials and Methods: Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). Results: No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P < 0.05). In open tray technique, there was a significant difference in the rotation of analogs compared with the master model with both impression materials (P < 0.05). Conclusion: There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings. PMID:25878678

  13. 43 CFR 3816.1 - Mineral locations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Mineral locations. 3816.1 Section 3816.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Reclamation Withdrawals § 3816.1 Mineral locations. The Act of April 23, 1932 (47 Stat. 136; 43...

  14. 43 CFR 3816.1 - Mineral locations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Mineral locations. 3816.1 Section 3816.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Reclamation Withdrawals § 3816.1 Mineral locations. The Act of April 23, 1932 (47 Stat. 136; 43...

  15. 43 CFR 3816.1 - Mineral locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Mineral locations. 3816.1 Section 3816.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Reclamation Withdrawals § 3816.1 Mineral locations. The Act of April 23, 1932 (47 Stat. 136; 43...

  16. 43 CFR 3816.1 - Mineral locations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Mineral locations. 3816.1 Section 3816.1..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LANDS AND MINERALS SUBJECT TO LOCATION Mineral Locations in Reclamation Withdrawals § 3816.1 Mineral locations. The Act of April 23, 1932 (47 Stat. 136; 43...

  17. Location-based information retrieval framework

    NASA Astrophysics Data System (ADS)

    Hariharan, Gurushyam; Mehta, Sandeep

    2003-03-01

    The recent advances in mobile communication technologies and their widespread use calls for a host of new value added services for the mobile user. In their current avatar, these deices are not more than mere communication equipments. Now consumer orientated, mobile, internet connected devices which are location aware (that are capable of determining and transmitting their current geographical location) are becoming available everywhere. The availability of internet access and location awareness in portable devices like cell phones, Personal Digital Assistants, etc. opens up a host of new opportunities for services which can en cash on the location of the user. Besides providing navigational information to the user, additional push down information can be sent to the user based on his profile and his preferences. The domain is wide and the number of applications is enormous. This paper presents a design and implementation of a basic location aware service.

  18. Underwater Acoustic Beacon Location System

    DTIC Science & Technology

    2016-12-23

    300087 1 of 31 UNDERWATER ACOUSTIC BEACON LOCATION SYSTEM [0001] The present application claims the benefit of United States Provisional...Application Serial Number 62/297,179 filed on February 19, 2016 by the inventor, Steven E. Crocker and entitled “ Underwater Acoustic Beacon...search for and can locate an underwater location beacon. Attorney Docket No. 300087 2 of 31 (2) Description of the Prior Art [0005

  19. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    PubMed

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of < 0.05 implied significance. Results Mean cyclophosphamide contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p < 0.0001), and 1.82 ± 0.10 ng/cm 2 (p < 0.0001), respectively. Control trays did not show detectable cyclophosphamide contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p < 0.0001), and 0.80 ± 0.15 ng/cm 2 (p = 0.0004), respectively. Conclusion Dispensing one or more prescriptions of 40 cyclophosphamide 50 mg tablets contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more

  20. Semantic Location Extraction from Crowdsourced Data

    NASA Astrophysics Data System (ADS)

    Koswatte, S.; Mcdougall, K.; Liu, X.

    2016-06-01

    Crowdsourced Data (CSD) has recently received increased attention in many application areas including disaster management. Convenience of production and use, data currency and abundancy are some of the key reasons for attracting this high interest. Conversely, quality issues like incompleteness, credibility and relevancy prevent the direct use of such data in important applications like disaster management. Moreover, location information availability of CSD is problematic as it remains very low in many crowd sourced platforms such as Twitter. Also, this recorded location is mostly related to the mobile device or user location and often does not represent the event location. In CSD, event location is discussed descriptively in the comments in addition to the recorded location (which is generated by means of mobile device's GPS or mobile communication network). This study attempts to semantically extract the CSD location information with the help of an ontological Gazetteer and other available resources. 2011 Queensland flood tweets and Ushahidi Crowd Map data were semantically analysed to extract the location information with the support of Queensland Gazetteer which is converted to an ontological gazetteer and a global gazetteer. Some preliminary results show that the use of ontologies and semantics can improve the accuracy of place name identification of CSD and the process of location information extraction.

  1. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2001-01-01

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  2. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-08

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  3. Extreme-UV lithography vacuum chamber zone seal

    DOEpatents

    Haney, Steven J.; Herron, Donald Joe; Klebanoff, Leonard E.; Replogle, William C.

    2003-04-15

    Control of particle contamination on the reticle and carbon contamination of optical surfaces in photolithography systems can be achieved by the establishment of multiple pressure zones in the photolithography systems. The different zones will enclose the reticle, projection optics, wafer, and other components of system. The system includes a vacuum apparatus that includes: a housing defining a vacuum chamber; one or more metrology trays situated within the vacuum chamber each of which is supported by at least one support member, wherein the tray separates the vacuum chamber into a various compartments that are maintained at different pressures; and conductance seal devices for adjoining the perimeter of each tray to an inner surface of the housing wherein the tray is decoupled from vibrations emanating from the inner surface of the housing.

  4. Sources and transport of silicone NVR

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.

    1992-01-01

    The retrieved LDEF had varying amounts of visible contamination films (brown stains) at many locations. FTIR spectra of heavy film deposits at vents and of optical windows from tray E5 indicated methyl silicone and silica in the contaminant films. Two possible sources of the methyl silicone are DC-710 phenyl methyl silicone in the shuttle-bay-liner beta cloth, and the shuttle tile waterproofing silane. It is concluded that much of the silicon and silica contamination came from ground operations and the orbiter.

  5. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohd, Shukri; Holford, Karen M.; Pullin, Rhys

    2014-02-12

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup usingmore » H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure.« less

  6. Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model

    PubMed Central

    2014-01-01

    Background In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. Methods We defined the radiodensity ranges for trabecular tibia bone, polymethylmethacrylate (PMMA) cement and cement-penetrated trabecular bone and measured the percentages of cement penetration at various depths after cementing two tibia prostheses onto redundant femoral heads. One prosthesis was subsequently removed to examine the influence of the metal tibia prostheses on the quality of the CT images. The percentages of cement penetration in the CT slices were compared with percentages measured with photographs of the corresponding transversal slices. Results Trabecular bone and cement-penetrated trabecular bone had no overlap in quantitative scale of radio-density. There was no significant difference in mean HU values when measuring with or without the tibia prosthesis. The percentages of measured cement-penetrated trabecular bone in the CT slices of the specimen were within the range of percentages that could be expected based on the measurements with the photographs (p = 0.04). Conclusions CT scan images provide valid results in measuring the penetration and distribution of cement into trabecular bone underneath the tibia component of a TKA. Since the proposed method does not turn metal elements into artefacts, it enables clinicians to assess the width and density of the cement mantle in vivo and to compare the results of different cementing methods in TKA. PMID:25158996

  7. Location perception: the X-Files parable.

    PubMed

    Prinzmetal, William

    2005-01-01

    Three aspects of visual object location were investigated: (1) how the visual system integrates information for locating objects, (2) how attention operates to affect location perception, and (3) how the visual system deals with locating an object when multiple objects are present. The theories were described in terms of a parable (the X-Files parable). Then, computer simulations were developed. Finally, predictions derived from the simulations were tested. In the scenario described in the parable, we ask how a system of detectors might locate an alien spaceship, how attention might be implemented in such a spaceship detection system, and how the presence of one spaceship might influence the location perception of another alien spaceship. Experiment 1 demonstrated that location information is integrated with a spatial average rule. In Experiment 2, this rule was applied to a more-samples theory of attention. Experiment 3 demonstrated how the integration rule could account for various visual illusions.

  8. The role of experience in location estimation: Target distributions shift location memory biases.

    PubMed

    Lipinski, John; Simmering, Vanessa R; Johnson, Jeffrey S; Spencer, John P

    2010-04-01

    Research based on the Category Adjustment model concluded that the spatial distribution of target locations does not influence location estimation responses [Huttenlocher, J., Hedges, L., Corrigan, B., & Crawford, L. E. (2004). Spatial categories and the estimation of location. Cognition, 93, 75-97]. This conflicts with earlier results showing that location estimation is biased relative to the spatial distribution of targets [Spencer, J. P., & Hund, A. M. (2002). Prototypes and particulars: Geometric and experience-dependent spatial categories. Journal of Experimental Psychology: General, 131, 16-37]. Here, we resolve this controversy by using a task based on Huttenlocher et al. (Experiment 4) with minor modifications to enhance our ability to detect experience-dependent effects. Results after the first block of trials replicate the pattern reported in Huttenlocher et al. After additional experience, however, participants showed biases that significantly shifted according to the target distributions. These results are consistent with the Dynamic Field Theory, an alternative theory of spatial cognition that integrates long-term memory traces across trials relative to the perceived structure of the task space. Copyright 2009 Elsevier B.V. All rights reserved.

  9. Discordance between location of positive cores in biopsy and location of positive surgical margin following radical prostatectomy.

    PubMed

    Kim, Ji Won; Park, Hyoung Keun; Kim, Hyeong Gon; Ham, Dong Yeub; Paick, Sung Hyun; Lho, Yong Soo; Choi, Woo Suk

    2015-10-01

    We compared location of positive cores in biopsy and location of positive surgical margin (PSM) following radical prostatectomy. This retrospective analysis included patients who were diagnosed as prostate cancer by standard 12-core transrectal ultrasonography guided prostate biopsy, and who have PSM after radical prostatectomy. After exclusion of number of biopsy cores <12, and lack of biopsy location data, 46 patients with PSM were identified. Locations of PSM in pathologic specimen were reported as 6 difference sites (apex, base and lateral in both sides). Discordance of biopsy result and PSM was defined when no positive cores in biopsy was identified at the location of PSM. Most common location of PSM were right apex (n=21) and left apex (n=15). Multiple PSM was reported in 21 specimens (45.7%). In 32 specimens (69.6%) with PSM, one or more concordant positive biopsy cores were identified, but 14 specimens (28%) had no concordant biopsy cores at PSM location. When discordant rate was separated by locations of PSM, right apex PSM had highest rate of discordant (38%). The discordant group had significantly lower prostate volume and lower number of positive cores in biopsy than concordant group. This study showed that one fourth of PSM occurred at location where tumor was not detected at biopsy and that apex PSM had highest rate of discordant. Careful dissection to avoid PSM should be performed in every location, including where tumor was not identified in biopsy.

  10. Access Control in Location-Based Services

    NASA Astrophysics Data System (ADS)

    Ardagna, Claudio A.; Cremonini, Marco; de Capitani di Vimercati, Sabrina; Samarati, Pierangela

    Recent enhancements in location technologies reliability and precision are fostering the development of a new wave of applications that make use of the location information of users. Such applications introduces new aspects of access control which should be addressed. On the one side, precise location information may play an important role and can be used to develop Location-based Access Control (LBAC) systems that integrate traditional access control mechanisms with conditions based on the physical position of users. On the other side, location information of users can be considered sensitive and access control solutions should be developed to protect it against unauthorized accesses and disclosures. In this chapter, we address these two aspects related to the use and protection of location information, discussing existing solutions, open issues, and some research directions.

  11. Location, Location, Location: How Would a High-Performing Charter School Network Fare in Different States?

    ERIC Educational Resources Information Center

    Lozier, Chris; Rotherham, Andrew J.

    2011-01-01

    In this paper the authors do not examine different operating strategies for charter schools or analyze the impact of their often educationally intensive models on finance. Instead, because public charter schools are funded predominantly by public dollars, they simply ask what impact location--and its associated variances in public funding and the…

  12. Optimising the location of antenatal classes.

    PubMed

    Tomintz, Melanie N; Clarke, Graham P; Rigby, Janette E; Green, Josephine M

    2013-01-01

    To combine microsimulation and location-allocation techniques to determine antenatal class locations which minimise the distance travelled from home by potential users. Microsimulation modeling and location-allocation modeling. City of Leeds, UK. Potential users of antenatal classes. An individual-level microsimulation model was built to estimate the number of births for small areas by combining data from the UK Census 2001 and the Health Survey for England 2006. Using this model as a proxy for service demand, we then used a location-allocation model to optimize locations. Different scenarios show the advantage of combining these methods to optimize (re)locating antenatal classes and therefore reduce inequalities in accessing services for pregnant women. Use of these techniques should lead to better use of resources by allowing planners to identify optimal locations of antenatal classes which minimise women's travel. These results are especially important for health-care planners tasked with the difficult issue of targeting scarce resources in a cost-efficient, but also effective or accessible, manner. (169 words). Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Accurate reconstruction of discontinuous mandible using a reverse engineering/computer-aided design/rapid prototyping technique: a preliminary clinical study.

    PubMed

    Zhou, Li-bin; Shang, Hong-tao; He, Li-sheng; Bo, Bin; Liu, Gui-cai; Liu, Yan-pu; Zhao, Jin-long

    2010-09-01

    To improve the reconstructive surgical outcome of a discontinuous mandibular defect, we used reverse engineering (RE), computer-aided design (CAD), and rapid prototyping (RP) technique to fabricate customized mandibular trays to precisely restore the mandibular defects. Autogenous bone grafting was also used to restore the bony continuity for occlusion rehabilitation. Six patients who had undergone block resection of the mandible underwent reconstruction using a custom titanium tray combining autogenous iliac grafts. The custom titanium tray was made using a RE/CAD/RP technique. A virtual 3-dimensional model was obtained by spiral computed tomography scanning. The opposite side of the mandible was mirrored to cover the defect area to restore excellent facial symmetry. A bone grafting tray was designed from the mirrored image and manufactured using RP processing and casting. The mandibular defects were restored using the trays in combination of autologous iliac grafting. An implant denture was made for 1 of the 6 patients at 24 weeks postoperatively for occlusion rehabilitation. The trays fabricated using this technique fit well in all 6 patients. The reconstructive procedures were easy and time saving. Satisfactory facial symmetry was restored. No severe complications occurred in the 5 patients without occlusion rehabilitation during a mean 50-month follow-up period. The reconstruction in the patient with occlusion lasted for only 1 year and failed eventually because of bone resorption and infection. Mandibular reconstruction was facilitated using the RE/CAD/RP technique. Satisfactory esthetic results were achieved. However, the rigidity of the cast tray could cause severe stress shielding to the grafts, which could lead to disuse atrophy. Therefore, some modification is needed for functional reconstruction. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Microbial composition affects the performance of an artificial Tephritid larval diet.

    PubMed

    Rempoulakis, P; Sela Saldinger, S; Nemny-Lavy, E; Pinto, R; Birke, A; Nestel, D

    2017-09-20

    The present study investigated the patterns of microorganisms in an artificial larval diet during Dacus ciliatus (Diptera; Tephritidae) larval development. Microbial population contents in the diet of total heterotrophic bacteria, yeast and molds, coliform and lactobacilli, and their dynamics during development, were monitored. Initially, the microbial composition in diet trays failing to produce viable pupae and in trays successfully producing pupae and adult flies was characterized. The failing diet trays contained large populations of lactobacilli that increased during larval development, and low populations of coliforms. In contrast, the successful diet showed an increasing population of coliforms and a low, or undetected, population of lactobacilli. To study the hypothesis that lactobacilli affect D. ciliatus larval development, we conducted controlled inoculation experiments in which Lactobacillus plantarum was added into fresh diet at the time of egg seeding. L. plantarum inoculated trays showed no production of D. ciliatus. Control trays without lactobacilli inoculation showed variable results. One tray successfully produced viable pupae and adults, and showed a slight and slow increase in the indigenous populations of lactobacilli. The second tray, however, failed to produce pupae and showed a fast increase of the indigenous lactobacilli to very high levels. Monitored pH trends in L. plantarum-inoculated diet showed a sharp pH decrease during the first 4 days of larval development from 5 to less than 4 units, while successful diet, producing viable D. ciliatus pupae and adults, showed a moderate pH drop during most of the larval development period. The paper discusses the possible ecological interactions between D. ciliatus larvae, the microbial content of the diet and the physical properties of the diet. The discussion also points out at the usefulness of this approach in understanding and managing mass production parameters of tephritid fruit flies

  15. Template-directed instrumentation in total knee arthroplasty: cost savings analysis.

    PubMed

    Hsu, Andrew R; Gross, Christopher E; Bhatia, Sanjeev; Levine, Brett R

    2012-11-01

    The use of digital radiography and templating software in total knee arthroplasty (TKA) continues to become more prevalent as the number of procedures performed increases every year. Template-directed instrumentation (TDI) is a novel approach to surgical planning that combines digital templating with limited intraoperative instruments. The purpose of this study was to evaluate the financial implications and radiographic outcomes of using TDI to direct instrumentation during primary TKA. Over a 1-year period, 82 consecutive TKAs using TDI were retrospectively reviewed. Patient demographics and preoperative templated sizes of predicted components were recorded, and OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida was used to determine the 2 most likely tibial and femoral component sizes for each case. This sizing information was used to direct component vendors to prepare 3 lightweight instrument trays based on these sizes. The sizes of implanted components and the number of total trays required were documented. A cost savings analysis was performed to compare TDI and non-TDI surgical expenses for TKA. In 80 (97%) of 82 cases, the prepared sizes determined by TDI using 3 instrument trays were sufficient. Preoperative templating correctly predicted the size of the tibial and femoral component sizes in 90% and 83% of cases, respectively. The average number of trays used with TDI was 3.0 (range, 3-5 trays) compared with 7.5 (range, 6-9 trays) used in 82 preceding non-TDI TKAs. Based on standard fees to sterilize and package implant trays (approximately $26 based on a survey of 10 orthopedic hospitals performing TKA), approximately $9612 was saved by using TDI over the 1-year study period. Overall, digital templating and TDI were a simple and cost-effective approach when performing primary TKA. Copyright 2012, SLACK Incorporated.

  16. Passive fit and accuracy of three dental implant impression techniques.

    PubMed

    Al Quran, Firas A; Rashdan, Bashar A; Zomar, AbdelRahman A Abu; Weiner, Saul

    2012-02-01

    To reassess the accuracy of three impression techniques relative to the passive fit of the prosthesis. An edentulous maxillary cast was fabricated in epoxy resin with four dental implants embedded and secured with heat-cured acrylic resin. Three techniques were tested: closed tray, open tray nonsplinted, and open tray splinted. One light-cured custom acrylic tray was fabricated for each impression technique, and transfer copings were attached to the implants. Fifteen impressions for each technique were prepared with medium-bodied consistency polyether. Subsequently, the impressions were poured in type IV die stone. The distances between the implants were measured using a digital micrometer. The statistical analysis of the data was performed with ANOVA and a one-sample t test at a 95% confidence interval. The lowest mean difference in dimensional accuracy was found within the direct (open tray) splinted technique. Also, the one-sample t test showed that the direct splinted technique has the least statistical significant difference from direct nonsplinted and indirect (closed tray) techniques. All discrepancies were less than 100 Μm. Within the limitations of this study, the best accuracy of the definitive prosthesis was achieved when the impression copings were splinted with autopolymerized acrylic resin, sectioned, and rejoined. However, the errors associated with all of these techniques were less than 100 Μm, and based on the current definitions of passive fit, they all would be clinically acceptable.

  17. Effect of comfort pads and incubator design on neonatal radiography.

    PubMed

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A; Lu, Zhengfeng

    2016-01-01

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: 1) both the comfort pad and support included in the beam, 2) only the support tray included and 3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient.

  18. Impact of mounting methods in computerized axiography on assessment of condylar inclination.

    PubMed

    Schierz, Oliver; Wagner, Philipp; Rauch, Angelika; Reissmann, Daniel R

    2017-08-30

    Valid and reliable recording is a key requirement for accurately simulating individual jaw movements. Horizontal condylar inclination (HCI) and Bennett's angle were measured using a digital jaw tracker (Cadiax® Compact 2) in 27 young adults. Three mounting methods (paraocclusal tray adapter, periocclusal tray adapter, and tray adapter with mandibular clamp) were tested. The mean values of the HCI differed by up to 10° between the mounting methods; however, the values for Bennett's angle did not differ substantially. While the intersession reliability of the Bennett's angle assessment did not depend on the mounting method, the reliability of the HCI assessment was only fair to good for the paraocclusal mounting method but poor for both periocclusal mounting methods. For attaching the tracing bow of jaw trackers to the mandible, a paraocclusal tray adapter should be applied, to achieve the most reliable results.

  19. Eldercare Locator

    MedlinePlus

    ... About Resources Welcome to the Eldercare Locator, a public service of the U.S. Administration on Aging connecting you to services for older ... Modified: 11/16/2016 1:05:04 PM Administration on Aging Feedback | Admin Portal | API ... FOIA | Plain Writing | No Fear Act | ACL.gov | USA.gov | HHS.gov

  20. 43 CFR 3830.10 - Locatable minerals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Locatable minerals. 3830.10 Section 3830..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING, RECORDING, AND MAINTAINING MINING CLAIMS OR SITES; GENERAL PROVISIONS Mining Law Minerals § 3830.10 Locatable minerals. ...

  1. 43 CFR 3830.10 - Locatable minerals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Locatable minerals. 3830.10 Section 3830..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING, RECORDING, AND MAINTAINING MINING CLAIMS OR SITES; GENERAL PROVISIONS Mining Law Minerals § 3830.10 Locatable minerals. ...

  2. 43 CFR 3830.10 - Locatable minerals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Locatable minerals. 3830.10 Section 3830..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING, RECORDING, AND MAINTAINING MINING CLAIMS OR SITES; GENERAL PROVISIONS Mining Law Minerals § 3830.10 Locatable minerals. ...

  3. 43 CFR 3830.10 - Locatable minerals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Locatable minerals. 3830.10 Section 3830..., DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING, RECORDING, AND MAINTAINING MINING CLAIMS OR SITES; GENERAL PROVISIONS Mining Law Minerals § 3830.10 Locatable minerals. ...

  4. Pilot Overmyer looks over food selections and experiments with beverage

    NASA Image and Video Library

    1982-11-16

    STS005-07-255 (19 Nov. 1982) --- Astronaut Robert F. Overmyer, STS-5 pilot, using beverage container and drinking straw secured in meal tray assembly (ASSY), experiments with microgravity characteristics of liquid on middeck in front of forward lockers. Overmyer also looks over packages of food attached to middeck lockers in meal tray assemblies. Carry-on food warmer appears overhead and other meal tray assemblies, personal hygiene mirror assembly, personal hygiene kit, and portrait of G.W.S. Abbey, Johnson Space Center's (JSC) Director of Flight Operations, appear on lockers. Photo credit: NASA

  5. Two hundred passage three-way valve: Fraction collector

    NASA Technical Reports Server (NTRS)

    Keffer, J. L.

    1983-01-01

    This paper describes the design and operation of a fraction collector used to direct flow of separated biological materials from 197 capillary tubes to either a collection tray or to a waste tank. This mechanism uses a 28-volt dc gear motor driving twin cams to force 197 needles through a self-sealing silicone rubber septum, where they inject the material in 197 separate pockets in a collection tray. The position of the collector tray is sensed by two optical limit switches. The time sequences are controlled automatically by an electronics control monitoring module.

  6. ARC-2006-ACD06-0091-016

    NASA Image and Video Library

    2006-06-05

    Space shuttle STS-121 FIT (Fly Immunity and Tumors) payload. Using Drosophila (fruit fly) to complete the experiments. Platform used by astronauts to change out old food trays with new food trays in space to facilitate culturing new flies.

  7. AFRICOM: Does Location Matter?

    DTIC Science & Technology

    2009-03-01

    Locating AFRICOM in Africa would be the first such posting of a unified combatant command ( UCC ) overseas during peacetime, where the nation is not...actively (i.e., kinetically) fighting or defending U.S. interests in its intended Area of Responsibility (AOR). Only two UCCs have resided on foreign soil...governments, the location or relocation of previous UCCs met with similar support and criticisms.18 More importantly, while logic of the preference

  8. Heat Retreat Locations in Cities - The Survey-Based Location Analysis of Heat Relief

    NASA Astrophysics Data System (ADS)

    Neht, Alice; Maximini, Claudia; Prenger-Berninghoff, Kathrin

    2017-12-01

    The adaptation of cities to climate change effects is one of the major strategies in urban planning to encounter the challenges of climate change (IPCC 2014). One of the fields of climate change adaption is dealing with heat events that occur more frequently and with greater intensity. Cities in particular are vulnerable to these events due to high population and infrastructure density. Proceeding urbanization calls for the existence of sufficient heat retreat locations (HRL) to enable relief for the population from heat in summer. This is why an extensive analysis of HRL is needed. This paper aims at the development of a survey-based location analysis of heat relief by identifying user groups, locations and characteristics of HRL based on a home survey that was conducted in three German cities. Key results of the study show that the majority of the participants of the survey are users of existing HRL, are affected by heat, and perceive heat as a burden in summer. Moreover, HRL that are located in close proximity are preferred by most users while their effect depends on the regional context that has to be considered in the analysis. Hence, this research presents an approach to heat relief that underlines the importance of HRL in cities by referring to selected examples of HRL types in densely populated areas of cities. HRL should especially be established and secured in densely built-up areas of cities. According to results of the survey, most HRL are located in public spaces, and the overall accessibility of HRL turned out to be an issue.

  9. FFTF Asbestos Location Tracking Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, J.A.

    1994-09-15

    An Asbestos Location Tracking Program was prepared to list, locate, and determine Asbestos content and to provide baseline {open_quotes}good faith{close_quotes} for yearly condition inspections for the FFTF Plant and buildings and grounds.

  10. It's All about Location, Location, Location: Children's Memory for the "Where'' of Personally Experienced Events

    ERIC Educational Resources Information Center

    Bauer, Patricia J.; Doydum, Ayzit O.; Pathman, Thanujeni; Larkina, Marina; Guler, O. Evren; Burch, Melissa

    2012-01-01

    Episodic memory is defined as the ability to recall specific past events located in a particular time and place. Over the preschool and into the school years, there are clear developmental changes in memory for when events took place. In contrast, little is known about developmental changes in memory for where events were experienced. In the…

  11. KENNEDY SPACE CENTER, FLA. - Japanese astronaut Koichi Wakata (left) works with a tray extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

    NASA Image and Video Library

    2003-09-24

    KENNEDY SPACE CENTER, FLA. - Japanese astronaut Koichi Wakata (left) works with a tray extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

  12. KENNEDY SPACE CENTER, FLA. - Japanese astronaut Koichi Wakata (right) works with a tray extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

    NASA Image and Video Library

    2003-09-24

    KENNEDY SPACE CENTER, FLA. - Japanese astronaut Koichi Wakata (right) works with a tray extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

  13. Googly Eyes

    ERIC Educational Resources Information Center

    Boss, Susan

    2009-01-01

    Beverage take-out trays are funky in their form and function. In this article, the author describes how to make googly eye masks out of discarded take-out trays and other common recycled or discarded materials. (Contains 1 online resource.)

  14. Corrosion inhibition for distillation apparatus

    DOEpatents

    Baumert, Kenneth L.; Sagues, Alberto A.; Davis, Burtron H.; Schweighardt, Frank K.

    1985-01-01

    Tower material corrosion in an atmospheric or sub-atmospheric distillation tower in a coal liquefaction process is reduced or eliminated by subjecting chloride-containing tray contents to an appropriate ion-exchange resin to remove chloride from such tray contents materials.

  15. Improved integrated sniper location system

    NASA Astrophysics Data System (ADS)

    Figler, Burton D.; Spera, Timothy J.

    1999-01-01

    In July of 1995, Lockheed Martin IR Imaging Systems, of Lexington, Massachusetts began the development of an integrated sniper location system for the Defense Advanced Research Projects Agency and for the Department of the Navy's Naval Command Control & Ocean Surveillance Center, RDTE Division in San Diego, California. The I-SLS integrates acoustic and uncooled infrared sensing technologies to provide an affordable and highly effective sniper detection and location capability. This system, its performance and results from field tests at Camp Pendleton, California, in October 1996 were described in a paper presented at the November 1996 SPIE Photonics East Symposium1 on Enabling Technologies for Law Enforcement and Security. The I-SLS combines an acoustic warning system with an uncooled infrared warning system. The acoustic warning system has been developed by SenTech, Inc., of Lexington, Massachusetts. This acoustic warning system provides sniper detection and coarse location information based upon the muzzle blast of the sniper's weapon and/or upon the shock wave produced by the sniper's bullet, if the bullet is supersonic. The uncooled infrared warning system provides sniper detection and fine location information based upon the weapon's muzzle flash. In addition, the uncooled infrared warning system can provide thermal imagery that can be used to accurately locate and identify the sniper. Combining these two technologies improves detection probability, reduces false alarm rate and increases utility. In the two years since the last report of the integrated sniper location system, improvements have been made and a second field demonstration was planned. In this paper, we describe the integrated sniper location system modifications in preparation for the new field demonstration. In addition, fundamental improvements in the uncooled infrared sensor technology continue to be made. These improvements include higher sensitivity (lower minimum resolvable temperature

  16. Locating the LCROSS Impact Craters

    NASA Technical Reports Server (NTRS)

    Marshall, William; Shirley, Mark; Moratto, Zachary; Colaprete, Anthony; Neumann, Gregory A.; Smith, David E.; Hensley, Scott; Wilson, Barbara; Slade, Martin; Kennedy, Brian; hide

    2012-01-01

    The Lunar CRater Observations and Sensing Satellite (LCROSS) mission impacted a spent Centaur rocket stage into a permanently shadowed region near the lunar south pole. The Sheperding Spacecraft (SSC) separated approx. 9 hours before impact and performed a small braking maneuver in order to observe the Centaur impact plume, looking for evidence of water and other volatiles, before impacting itself. This paper describes the registration of imagery of the LCROSS impact region from the mid- and near-infrared cameras onboard the SSC, as well as from the Goldstone radar. We compare the Centaur impact features, positively identified in the first two, and with a consistent feature in the third, which are interpreted as a 20 m diameter crater surrounded by a 160 m diameter ejecta region. The images are registered to Lunar Reconnaisance Orbiter (LRO) topographical data which allows determination of the impact location. This location is compared with the impact location derived from ground-based tracking and propagation of the spacecraft's trajectory and with locations derived from two hybrid imagery/trajectory methods. The four methods give a weighted average Centaur impact location of -84.6796 deg, -48.7093 deg, with a 1s uncertainty of 115 m along latitude, and 44 m along longitude, just 146 m from the target impact site. Meanwhile, the trajectory-derived SSC impact location is -84.719 deg, -49.61 deg, with a 1 alpha uncertainty of 3 m along the Earth vector and 75 m orthogonal to that, 766 m from the target location and 2.803 km south-west of the Centaur impact. We also detail the Centaur impact angle and SSC instrument pointing errors. Six high-level LCROSS mission requirements are shown to be met by wide margins. We hope that these results facilitate further analyses of the LCROSS experiment data and follow-up observations of the impact region

  17. 47 CFR 73.1120 - Station location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Station location. 73.1120 Section 73.1120... Rules Applicable to All Broadcast Stations § 73.1120 Station location. Each AM, FM, TV and Class A TV... be the geographical station location. [65 FR 30003, May 10, 2000] ...

  18. 47 CFR 22.657 - Transmitter locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Transmitter locations. 22.657 Section 22.657... Paging and Radiotelephone Service 470-512 Mhz Trunked Mobile Operation § 22.657 Transmitter locations... public mobile operations on these channels will occur. The protected TV station locations specified in...

  19. 10 CFR 75.11 - Location information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Location information. 75.11 Section 75.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) SAFEGUARDS ON NUCLEAR MATERIAL-IMPLEMENTATION OF US/IAEA AGREEMENT Facility and Location Information § 75.11 Location information. (a) As required by the Additional Protocol...

  20. 47 CFR 101.129 - Transmitter location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter location. 101.129 Section 101.129... SERVICES Technical Standards § 101.129 Transmitter location. (a) The applicant must determine, prior to... adequate to render the service proposed. In cases of questionable antenna locations, it is desirable to...

  1. Within-person associations of young adolescents' physical activity across five primary locations: is there evidence of cross-location compensation?

    PubMed

    Carlson, Jordan A; Mitchell, Tarrah B; Saelens, Brian E; Staggs, Vincent S; Kerr, Jacqueline; Frank, Lawrence D; Schipperijn, Jasper; Conway, Terry L; Glanz, Karen; Chapman, Jim E; Cain, Kelli L; Sallis, James F

    2017-04-20

    Youth are active in multiple locations, but it is unknown whether more physical activity in one location is associated with less in other locations. This cross-sectional study examines whether on days with more physical activity in a given location, relative to their typical activity in that location, youth had less activity in other locations (i.e., within-person associations/compensation). Participants were 528 adolescents, ages 12 to 16 (M = 14.12, SD = 1.44, 50% boys, 70% White non-Hispanic). Accelerometer and Global Positioning System devices were used to measure the proportion of time spent in moderate-to-vigorous physical activity (MVPA) in five locations: home, home neighborhood, school, school neighborhood, and other locations. Mixed-effects regression was used to examine within-person associations of MVPA across locations and moderators of these associations. Two of ten within-participant associations tested indicated small amounts of compensation, and one association indicated generalization across locations. Higher at-school MVPA (relative to the participant's average) was related to less at-home MVPA and other-location MVPA (Bs = -0.06 min/day). Higher home-neighborhood MVPA (relative to the participant's average) was related to more at-home MVPA (B = 0.07 min/day). Some models showed that compensation was more likely (or generalization less likely) in boys and non-whites or Hispanic youth. Consistent evidence of compensation across locations was not observed. A small amount of compensation was observed for school physical activity, suggesting that adolescents partially compensated for high amounts of school activity by being less active in other locations. Conversely, home-neighborhood physical activity appeared to carry over into the home, indicating a generalization effect. Overall these findings suggest that increasing physical activity in one location is unlikely to result in meaningful decreases in other locations. Supporting

  2. Protecting Privacy and Securing the Gathering of Location Proofs - The Secure Location Verification Proof Gathering Protocol

    NASA Astrophysics Data System (ADS)

    Graham, Michelle; Gray, David

    As wireless networks become increasingly ubiquitous, the demand for a method of locating a device has increased dramatically. Location Based Services are now commonplace but there are few methods of verifying or guaranteeing a location provided by a user without some specialised hardware, especially in larger scale networks. We propose a system for the verification of location claims, using proof gathered from neighbouring devices. In this paper we introduce a protocol to protect this proof gathering process, protecting the privacy of all involved parties and securing it from intruders and malicious claiming devices. We present the protocol in stages, extending the security of this protocol to allow for flexibility within its application. The Secure Location Verification Proof Gathering Protocol (SLVPGP) has been designed to function within the area of Vehicular Networks, although its application could be extended to any device with wireless & cryptographic capabilities.

  3. 2. AERIAL VIEW OF SLC3 FROM THE NORTH. SLC3W IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. AERIAL VIEW OF SLC-3 FROM THE NORTH. SLC-3W IN FOREGROUND; SLC-3E IN BACKGROUND. LAUNCH OPERATIONS BUILDING (LOB; BLDG. 763) AND CABLE TRAYS BETWEEN LOB AND THE PADS VISIBLE IMMEDIATELY EAST (LEFT) OF THE PADS. VEHICLE SUPPORT BUILDING (BLDG. 766) LOCATED EAST OF ROAD IN LEFT FOREGROUND. TECHNICAL SUPPORT BUILDING (BLDG. 762/762A) AND SLC-3 AIR FORCE BUILDING (BLDG. 761) VISIBLE EAST OF LOG IN LEFT BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  4. 49 CFR 176.63 - Stowage locations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Stowage locations. 176.63 Section 176.63... and Stowage § 176.63 Stowage locations. (a) The table in § 172.101 of this subchapter specifies generally the locations authorized for stowage of the various hazardous materials on board vessels. This...

  5. 49 CFR 800.5 - Office locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Office locations. 800.5 Section 800.5... ORGANIZATION AND FUNCTIONS OF THE BOARD AND DELEGATIONS OF AUTHORITY Organization and Functions § 800.5 Office locations. The principal offices of the National Transportation Safety Board are located at 490 L'Enfant...

  6. 49 CFR 176.63 - Stowage locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Stowage locations. 176.63 Section 176.63... and Stowage § 176.63 Stowage locations. (a) The table in § 172.101 of this subchapter specifies generally the locations authorized for stowage of the various hazardous materials on board vessels. This...

  7. 46 CFR 76.50-10 - Location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Location. 76.50-10 Section 76.50-10 Shipping COAST GUARD... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  8. Lightning Location Using Acoustic Signals

    NASA Astrophysics Data System (ADS)

    Badillo, E.; Arechiga, R. O.; Thomas, R. J.

    2013-05-01

    In the summer of 2011 and 2012 a network of acoustic arrays was deployed in the Magdalena mountains of central New Mexico to locate lightning flashes. A Times-Correlation (TC) ray-tracing-based-technique was developed in order to obtain the location of lightning flashes near the network. The TC technique, locates acoustic sources from lightning. It was developed to complement the lightning location of RF sources detected by the Lightning Mapping Array (LMA) developed at Langmuir Laboratory, in New Mexico Tech. The network consisted of four arrays with four microphones each. The microphones on each array were placed in a triangular configuration with one of the microphones in the center of the array. The distance between the central microphone and the rest of them was about 30 m. The distance between centers of the arrays ranged from 500 m to 1500 m. The TC technique uses times of arrival (TOA) of acoustic waves to trace back the location of thunder sources. In order to obtain the times of arrival, the signals were filtered in a frequency band of 2 to 20 hertz and cross-correlated. Once the times of arrival were obtained, the Levenberg-Marquardt algorithm was applied to locate the spatial coordinates (x,y, and z) of thunder sources. Two techniques were used and contrasted to compute the accuracy of the TC method: Nearest-Neighbors (NN), between acoustic and LMA located sources, and standard deviation from the curvature matrix of the system as a measure of dispersion of the results. For the best case scenario, a triggered lightning event, the TC method applied with four microphones, located sources with a median error of 152 m and 142.9 m using nearest-neighbors and standard deviation respectively.; Results of the TC method in the lightning event recorded at 18:47:35 UTC, August 6, 2012. Black dots represent the results computed. Light color dots represent the LMA data for the same event. The results were obtained with the MGTM station (four channels). This figure

  9. Establishment of a medium-scale mosquito facility: optimization of the larval mass-rearing unit for Aedes albopictus (Diptera: Culicidae).

    PubMed

    Zhang, Dongjing; Zhang, Meichun; Wu, Yu; Gilles, Jeremie R L; Yamada, Hanano; Wu, Zhongdao; Xi, Zhiyong; Zheng, Xiaoying

    2017-11-13

    Standardized larval rearing units for mosquito production are essential for the establishment of a mass-rearing facility. Two larval rearing units, developed respectively by the Guangzhou Wolbaki Biotech Co. Ltd. (Wolbaki) and Insect Pest Control Laboratory, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture (FAO/IAEA-IPCL), are tested to assess their potential uses to mass-rear the larval stages of Aedes albopictus in support of the establishment of a medium-scale mosquito facility for the application of mosquito genetic control strategies. The triple Wolbachia-infected Ae. albopictus strain (HC strain) was used in this study. The effects of larval densities of two larval rearing trays (corresponding to 2.4, 3.0 and 3.6 larvae/cm 2 ) and tray size/position (top, middle and bottom layers) on the pupae production and larval survival were assessed when trays were stacked within the larval rearing units. The male pupae production, female pupae contamination after sex separation, and male mating competitiveness were also studied by using both larval rearing units in their entirety. The optimal larval rearing density for Wolbaki-tray (Wol-tray) was 6,600 larvae (equal to 3.0 larvae/cm 2 ) and 18,000 larvae (3.6 larvae/cm 2 ) for the FAO/IAEA-IPCL tray (IAEA-tray). No significant difference in pupae production was observed when trays were stacked within top, middle or bottom layers for both units. At thirty-four hours after the first pupation, the average male pupae production was (0.89 × 10 5 ) for the Wol-unit and (3.16 × 10 5 ) for the IAEA-unit. No significant difference was observed in female pupae contamination between these two units. The HC males showed equal male mating competitiveness to wild type males for mating with wild type females in large cages, regardless of whether they were reared in the Wol-unit or IAEA-unit. The current study has indicated that both the Wol-unit and IAEA-unit are suitable for larvae mass-rearing for Ae

  10. Smart Location Mapping

    EPA Pesticide Factsheets

    The Smart Location Database, Access to Jobs and Workers via Transit, and National Walkability Index tools can help assess indicators related to the built environment, transit accessibility, and walkability.

  11. 46 CFR 95.50-10 - Location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location. 95.50-10 Section 95.50-10 Shipping COAST GUARD...-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in accordance with Table 95.50-10(a). The location of the equipment shall be to...

  12. Lunar Impact Flash Locations

    NASA Technical Reports Server (NTRS)

    Moser, D. E.; Suggs, R. M.; Kupferschmidt, L.; Feldman, J.

    2015-01-01

    A bright impact flash detected by the NASA Lunar Impact Monitoring Program in March 2013 brought into focus the importance of determining the impact flash location. A process for locating the impact flash, and presumably its associated crater, was developed using commercially available software tools. The process was successfully applied to the March 2013 impact flash and put into production on an additional 300 impact flashes. The goal today: provide a description of the geolocation technique developed.

  13. 7 CFR 457.162 - Nursery crop insurance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...

  14. 7 CFR 457.162 - Nursery crop insurance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...

  15. 7 CFR 457.162 - Nursery crop insurance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...

  16. 7 CFR 457.162 - Nursery crop insurance provisions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... inch in diameter (including trays containing 200 or fewer individual cells, unless specifically... or cell interior, have an established root system, and meet all other conditions specified in the... container interior (including trays that contain 200 or fewer individual cells, unless specifically provided...

  17. 77 FR 63771 - Implementation of Full-Service Intelligent Mail Requirements for Automation Prices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-17

    ... tray barcodes (IMtb) on trays, tubs, and sacks; apply unique Intelligent Mail container barcodes (IMcb) on placards for containers, such as pallets; schedule appointments through Facility Access and... preparation of mail, which provides high-value services and enables efficient mail processing. The strategic...

  18. Geostar - Navigation location system

    NASA Astrophysics Data System (ADS)

    Keyser, Donald A.

    The author describes the Radiodetermination Satellite Service (RDSS). The initial phase of the RDSS provides for a unique service enabling central offices and headquarters to obtain position-location information and receive short digital messages from mobile user terminals throughout the contiguous United States, southern Canada, and northern Mexico. The system employs a spread-spectrum, CDMA modulation technique allowing multiple customers to use the system simultaneously, without preassigned coordination with fellow users. Position location is currently determined by employing an existing radio determination receiver, such as Loran-C, GPS, or Transit, in the mobile user terminal. In the early 1990s position location will be determined at a central earth station by time-differential ranging of the user terminals via two or more geostationary satellites. A brief overview of the RDSS system architecture is presented with emphasis on the user terminal and its diverse applications.

  19. Are pain location and physical examinations useful in locating a tear site of the rotator cuff?

    PubMed

    Itoi, Eiji; Minagawa, Hiroshi; Yamamoto, Nobuyuki; Seki, Nobutoshi; Abe, Hidekazu

    2006-02-01

    Pain is the most common symptom of patients with rotator cuff tendinopathy, but little is known about the relationship between the site of pain and the site of cuff pathologic lesions. Also, accuracies of physical examinations used to locate a tear by assessing the muscle strength seem to be affected by the threshold for muscle weakness, but no studies have been reported regarding the efficacies of physical examinations in reference to their threshold. Pain location is useful in locating a tear site. Efficacies of physical examinations to evaluate the function of the cuff muscles depend on the threshold for muscle weakness. Case series; Level of evidence, 4. The authors retrospectively reviewed the clinical charts of 160 shoulders of 149 patients (mean age, 53 years) with either rotator cuff tears (140 shoulders) or cuff tendinitis (20 shoulders). The location of pain was recorded on a standardized form with 6 different areas. The diagnostic accuracies of the following tests were assessed with various thresholds for muscle weakness: supraspinatus test, the external rotation strength test, and the lift-off test. Lateral and anterior portions of the shoulder were the most common sites of pain regardless of existence of tear or tear location. The supraspinatus test was most accurate when it was assessed to have positive results with the muscle strength less than manual muscle testing grade 5, whereas the lift-off test was most accurate with a threshold less than grade 3. The external rotation strength test was most accurate with a threshold of less than grade 4+. The authors conclude that pain location is not useful in locating the site of a tear, whereas the physical examinations aiming to locate the tear site are clinically useful when assessed to have positive results with appropriate threshold for muscle weakness.

  20. 5 CFR 960.103 - Location.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Location. 960.103 Section 960.103 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) FEDERAL EXECUTIVE BOARDS § 960.103 Location. Federal Executive Boards have been established and shall continue in...

  1. Electric current locator

    DOEpatents

    King, Paul E [Corvallis, OR; Woodside, Charles Rigel [Corvallis, OR

    2012-02-07

    The disclosure herein provides an apparatus for location of a quantity of current vectors in an electrical device, where the current vector has a known direction and a known relative magnitude to an input current supplied to the electrical device. Mathematical constants used in Biot-Savart superposition equations are determined for the electrical device, the orientation of the apparatus, and relative magnitude of the current vector and the input current, and the apparatus utilizes magnetic field sensors oriented to a sensing plane to provide current vector location based on the solution of the Biot-Savart superposition equations. Description of required orientations between the apparatus and the electrical device are disclosed and various methods of determining the mathematical constants are presented.

  2. Simon and Garner effects with color and location: Evidence for two independent routes by which irrelevant location influences performance.

    PubMed

    Fitousi, Daniel

    2016-11-01

    Classic theories of attention assume that the processing of a target's featural dimension (e.g., color) is contingent on the processing of its spatial location. The present study challenges this maxim. Three experiments evaluated the dimensional independence of spatial location and color using a combined Simon (Simon & Rudell Journal of Applied Psychology: 51, 300-304, 1967) and Garner (Garner, 1974) design. The results showed that when the stimulus's spatial location was rendered more discriminable than its color (Experiment 1 and 2), both Simon and Garner effects were obtained, and location interfered with color judgments to a larger extent than color intruded on location. However, when baseline discriminabilities of location and color were matched (Experiment 3), no Garner interference was obtained from location to color, yet Simon effects still emerged, proving resilient to manipulations of discriminability. Further correlational and distributional analyses showed that Garner and Simon effects have dissociable effects. A triple-route model is proposed to account for the results, according to which irrelevant location can influence performance via two independent location routes/codes.

  3. Effects of the LDEF orbital environment on the reflectance of optical mirror materials

    NASA Technical Reports Server (NTRS)

    Herzig, Howard; Fleetwood, Charles, Jr.

    1995-01-01

    Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.

  4. Changes in oxidation state of chromium during LDEF exposure

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.

    1992-01-01

    The solar collector used for the McDonnell-Douglas Cascade Variable Heat Pipe, Experiment A0076 (Michael Grote - Principal Investigator) was finished with black chromium plating as a thermal control coating. The coating is metallic for low emittance, and is finely microcrystalline to a dimension which yields its high absorptivity. An underplate of nickel was applied to the aluminum absorber plate in order to achieve optimal absorptance characteristics from the black chromium plate surface. Experiment A0076 was located at tray position F9, receiving a projected 8.7 x 10 exp 21 atomic oxygen atoms/sq cm and 11,200 ESH solar radiation. During retrieval, it was observed that the aluminized kapton thermal blankets covering most of the tray were severely eroded by atomic oxygen, and that a 'flap' of aluminum foil was overlaying a roughly triangular shaped portion of the absorber panel. The aluminum foil 'flap' was lost sometime between the Long Duration Exposure Facility (LDEF) retrieval and deintegration. At deintegration, the black chromium was observed to have discolored where it had been covered by the foil 'flap'. A summary of the investigation into the cause of the discoloration is presented.

  5. Silicon production process evaluations

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Chemical engineering analysis was continued for the HSC process (Hemlock Semiconductor Corporation) in which solar cell silicon is produced in a 1,000 MT/yr plant. Progress and status are reported for the primary engineering activities involved in the preliminary process engineering design of the plant base case conditions (96%), reaction chemistry (96%), process flow diagram (85%), material balance (85%), energy balance (60%), property data (60%), equipment design (40%), major equipment list (30%) and labor requirements (10%). Engineering design of the second distillation column (D-02, TCS column) in the process was completed. The design is based on a 97% recovery of the light key (TCS, trichlorosilane) in the distillate and a 97% recovery of the heavy key (TET, silicon tetrachloride) in the bottoms. At a reflux ratio of 2, the specified recovery of TCS and TET is achieved with 20 trays (equilibrium stages, N=20). Respective feed tray locations are 9, 12 and 15 (NF sub 1 = 9, NF sub 2 = 12,, and NF sub 3 = 15). A total condenser is used for the distillation which is conducted at a pressure of 90 psia.

  6. Locating difficult veins for venepuncture and cannulation.

    PubMed

    Shaw, Sally Jane

    2017-02-15

    Vein location and assessment are essential to improve the success rates for vascular access. However, problems remain with first attempt success rates for peripheral cannulation and locating difficult veins. Practitioners may not be aware of developments in technology and aids to assist in the location and assessment of veins to achieve vascular access. This article provides an overview of two vein location aids that can be used to locate difficult veins: the IV-eye vein imager and the Vacuderm tourniquet. It discusses the patient factors that can increase the difficulty of vein assessment and location, and emphasises the importance of vessel health and preservation, and vein palpation. Practitioners should be experienced and skilled in the assessment of veins, and they are encouraged to revisit how they locate and assess veins.

  7. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  8. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  9. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  10. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  11. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  12. Checking in: Location Services for Libraries

    ERIC Educational Resources Information Center

    Rethlefsen, Melissa L.

    2010-01-01

    As always in real estate, everything in technology these days seems to be about location. From Google's recent addition of a "nearby" location limit to its suite of search options to the spate of location-based mobile apps and social networks, physical proximity has become the linchpin of a trend to connect technology to the real world. In this…

  13. Teaching Health Center Graduate Medical Education Locations Predominantly Located in Federally Designated Underserved Areas.

    PubMed

    Barclift, Songhai C; Brown, Elizabeth J; Finnegan, Sean C; Cohen, Elena R; Klink, Kathleen

    2016-05-01

    Background The Teaching Health Center Graduate Medical Education (THCGME) program is an Affordable Care Act funding initiative designed to expand primary care residency training in community-based ambulatory settings. Statute suggests, but does not require, training in underserved settings. Residents who train in underserved settings are more likely to go on to practice in similar settings, and graduates more often than not practice near where they have trained. Objective The objective of this study was to describe and quantify federally designated clinical continuity training sites of the THCGME program. Methods Geographic locations of the training sites were collected and characterized as Health Professional Shortage Area, Medically Underserved Area, Population, or rural areas, and were compared with the distribution of Centers for Medicare and Medicaid Services (CMS)-funded training positions. Results More than half of the teaching health centers (57%) are located in states that are in the 4 quintiles with the lowest CMS-funded resident-to-population ratio. Of the 109 training sites identified, more than 70% are located in federally designated high-need areas. Conclusions The THCGME program is a model that funds residency training in community-based ambulatory settings. Statute suggests, but does not explicitly require, that training take place in underserved settings. Because the majority of the 109 clinical training sites of the 60 funded programs in 2014-2015 are located in federally designated underserved locations, the THCGME program deserves further study as a model to improve primary care distribution into high-need communities.

  14. Imaging the neonate in the incubator: an investigation of the technical, radiological and nursing issues.

    PubMed

    Mutch, S J; Wentworth, S D P

    2007-11-01

    Modern neonatal incubators incorporate an X-ray tray device into the mattress support structure to facilitate patient examination with minimal disturbance and distress. However, the usual method of examination is to place the image plate directly underneath the baby. Users often cite radiological reasons for not using X-ray trays but modern quantitative evidence is lacking. This work looks at the technical and clinical aspects of imaging neonates in incubators and the impact that these may have in determining the imaging protocol. A number of hospitals were surveyed to determine their current method of examination and the reasons for their preference. Experimental measurements of the radiological impact of using (or not using) the X-ray tray were performed for a range of neonatal incubators. The average dose to the image plate was 5.9 microGy (range 5.4-6.4 microGy) for the "plate on mattress" method and 3.0 microGy (2.0-3.8 microGy) when using the tray--a 49% reduction owing to the mattress support materials. However, when using a computed radiography (CR) imaging system, the image quality differences were marginal. Survey results indicated that nurses preferred to use the tray but that radiographers were reluctant. We conclude that incubator manufacturers could do much to improve the radiological performance of their equipment and we offer recommendations. We also conclude that, with appropriate nurse and radiographer training and the advent of CR imaging systems, use of X-ray tray facilities may optimize imaging of the neonate in the incubator.

  15. Three-dimensional accuracy of different impression techniques for dental implants

    PubMed Central

    Nakhaei, Mohammadreza; Madani, Azam S; Moraditalab, Azizollah; Haghi, Hamidreza Rajati

    2015-01-01

    Background: Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. Materials and Methods: Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BIO), Straumann tissue-level (STL), and Straumann bone-level (SBL). Forty-two putty/wash polyvinyl siloxane impressions of the models were made using open-tray and closed-tray techniques. Closed-tray impressions were made using snap-on (STL model), transfer coping (TC) (BIO model) and TC plus plastic cap (TC-Cap) (SBL model). The impressions were poured with type IV stone, and the positional accuracy of the implant analog heads in each dimension (x, y and z axes), and the linear displacement (ΔR) were evaluated using a coordinate measuring machine. Data were analyzed using ANOVA and post-hoc Tukey tests (α = 0.05). Results: The ΔR values of the snap-on technique were significantly lower than those of TC and TC-Cap techniques (P < 0.001). No significant differences were found between closed and open impression techniques for STL in Δx, Δy, Δz and ΔR values (P = 0.444, P = 0.181, P = 0.835 and P = 0.911, respectively). Conclusion: Considering the limitations of this study, the snap-on implant-level impression technique resulted in more three-dimensional accuracy than TC and TC-Cap, but it was similar to the open-tray technique. PMID:26604956

  16. Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study

    PubMed Central

    Selvaraj, Sunantha; Dorairaj, Jayachandran; Mohan, Jayashree; Simon, Paul

    2016-01-01

    Introduction: An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. Objective: The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. Methodology: A mandibular reference model with four ADIN implants was done. Ten custom trays were fabricated using the light curable resin sheets. Medium body polyether impression material was used. These trays were randomly divided between the two groups, with five trays in each group. Impression techniques were divided into two groups namely: Group A: Direct impression technique with open tray impression copings splinted with autopolymerizing acrylic resin (GC pattern resin). Group B: Direct impression technique with open tray impression copings splinted with Pro-temp TM 4 (bis-GMA) syringable temporization material. Thus, final impressions were made. Total of 10 master casts were fabricated. Evaluation of casts using Dynascope-Vision Engineering, TESA microhite two- dimension and coordinate measuring machine were used. Results: Statistical comparisons were made using ANOVA test and post-hoc test. Same amount of deviation values obtained with resin splinted and bis-GMA splinted impression copings. Conclusion: The master cast obtained by both the splinting material exhibits no difference from the reference model. So bis-GMA can be used, which is easy to handle, less time consuming, less technique sensitive, rigid, and readily available material in clinics. PMID:27141167

  17. [Location selection for Shenyang urban parks based on GIS and multi-objective location allocation model].

    PubMed

    Zhou, Yuan; Shi, Tie-Mao; Hu, Yuan-Man; Gao, Chang; Liu, Miao; Song, Lin-Qi

    2011-12-01

    Based on geographic information system (GIS) technology and multi-objective location-allocation (LA) model, and in considering of four relatively independent objective factors (population density level, air pollution level, urban heat island effect level, and urban land use pattern), an optimized location selection for the urban parks within the Third Ring of Shenyang was conducted, and the selection results were compared with the spatial distribution of existing parks, aimed to evaluate the rationality of the spatial distribution of urban green spaces. In the location selection of urban green spaces in the study area, the factor air pollution was most important, and, compared with single objective factor, the weighted analysis results of multi-objective factors could provide optimized spatial location selection of new urban green spaces. The combination of GIS technology with LA model would be a new approach for the spatial optimizing of urban green spaces.

  18. 49 CFR 214.331 - Definite train location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Definite train location. 214.331 Section 214.331... location. A roadway worker may establish on-track safety by using definite train location only where... may only use definite train location to establish on-track safety at points where such procedures were...

  19. 12 CFR 204.3 - Reporting and location.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 2 2010-01-01 2010-01-01 false Reporting and location. 204.3 Section 204.3... REQUIREMENTS OF DEPOSITORY INSTITUTIONS (REGULATION D) § 204.3 Reporting and location. (a) Every depository... corporation is located in the Federal Reserve District that contains the location specified in the institution...

  20. A Bayesian framework for infrasound location

    NASA Astrophysics Data System (ADS)

    Modrak, Ryan T.; Arrowsmith, Stephen J.; Anderson, Dale N.

    2010-04-01

    We develop a framework for location of infrasound events using backazimuth and infrasonic arrival times from multiple arrays. Bayesian infrasonic source location (BISL) developed here estimates event location and associated credibility regions. BISL accounts for unknown source-to-array path or phase by formulating infrasonic group velocity as random. Differences between observed and predicted source-to-array traveltimes are partitioned into two additive Gaussian sources, measurement error and model error, the second of which accounts for the unknown influence of wind and temperature on path. By applying the technique to both synthetic tests and ground-truth events, we highlight the complementary nature of back azimuths and arrival times for estimating well-constrained event locations. BISL is an extension to methods developed earlier by Arrowsmith et al. that provided simple bounds on location using a grid-search technique.

  1. Perceptual grouping allows for attention to cover noncontiguous locations and suppress capture from nearby locations.

    PubMed

    Kerzel, Dirk; Born, Sabine; Schönhammer, Josef

    2012-12-01

    A salient stimulus may interrupt visual search because of attentional capture. It has been shown that attentional capture occurs with a wide, but not with a small attentional window. We tested the hypothesis that capture depends more strongly on the shape of the attentional window than on its size. Search elements were arranged in two nested rings. The ring containing the search target remained fixed, while a salient color singleton occurred either in the same or in the other ring. We observed that color singletons only disrupted search when shown in the same ring as the search target. It is important to note that, when focusing on the outer array, which presumably required a larger attentional window, singletons on the inner array did not capture attention. In contrast to the original attentional window hypothesis, our results show that attentional capture does not always occur with a large attentional window. Rather, attention can be flexibly allocated to the set of relevant stimulus locations and attentional capture is confined to the attended locations. Further experiments showed that attention was allocated to search elements that were perceptually grouped into "whole" or "Gestalt"-like objects, which prevented attentional capture from nearby locations. However, when attention was allocated to noncontiguous locations that did not form a perceptual Gestalt, nearby locations elicited attentional capture. Perceptual grouping could be based on a combination of color and position, but not on color alone. Thus, the allocation of attention to Gestalt-like objects that were jointly defined by similarity and proximity prevented attentional capture from nearby locations.

  2. 46 CFR 154.1816 - Cargo location plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo location plan. 154.1816 Section 154.1816 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1816 Cargo location plan. The master shall ensure that: (a) A cargo location plan is prepared that gives: (1) The location and...

  3. 49 CFR 192.5 - Class locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... assembly) that is occupied by 20 or more persons on at least 5 days a week for 10 weeks in any 12-month period. (The days and weeks need not be consecutive.) (4) A Class 4 location is any class location unit... 2, 3, and 4 may be adjusted as follows: (1) A Class 4 location ends 220 yards (200 meters) from the...

  4. FUEL SUBASSEMBLY CONSTRUCTION FOR RADIAL FLOW IN A NUCLEAR REACTOR

    DOEpatents

    Treshow, M.

    1962-12-25

    An assembly of fuel elements for a boiling water reactor arranged for radial flow of the coolant is described. The ingress for the coolant is through a central header tube, perforated with parallel circumferertial rows of openings each having a lip to direct the coolant flow downward. Around the central tube there are a number of equally spaced concentric trays, closely fitiing the central header tube. Cylindrical fuel elements are placed in a regular pattern around the central tube, piercing the trays. A larger tube encloses the arrangement, with space provided for upward flow of coolart beyond the edge of the trays. (AEC)

  5. Acoustic Location of Lightning Using Interferometric Techniques

    NASA Astrophysics Data System (ADS)

    Erives, H.; Arechiga, R. O.; Stock, M.; Lapierre, J. L.; Edens, H. E.; Stringer, A.; Rison, W.; Thomas, R. J.

    2013-12-01

    Acoustic arrays have been used to accurately locate thunder sources in lightning flashes. The acoustic arrays located around the Magdalena mountains of central New Mexico produce locations which compare quite well with source locations provided by the New Mexico Tech Lightning Mapping Array. These arrays utilize 3 outer microphones surrounding a 4th microphone located at the center, The location is computed by band-passing the signal to remove noise, and then computing the cross correlating the outer 3 microphones with respect the center reference microphone. While this method works very well, it works best on signals with high signal to noise ratios; weaker signals are not as well located. Therefore, methods are being explored to improve the location accuracy and detection efficiency of the acoustic location systems. The signal received by acoustic arrays is strikingly similar to th signal received by radio frequency interferometers. Both acoustic location systems and radio frequency interferometers make coherent measurements of a signal arriving at a number of closely spaced antennas. And both acoustic and interferometric systems then correlate these signals between pairs of receivers to determine the direction to the source of the received signal. The primary difference between the two systems is the velocity of propagation of the emission, which is much slower for sound. Therefore, the same frequency based techniques that have been used quite successfully with radio interferometers should be applicable to acoustic based measurements as well. The results presented here are comparisons between the location results obtained with current cross correlation method and techniques developed for radio frequency interferometers applied to acoustic signals. The data were obtained during the summer 2013 storm season using multiple arrays sensitive to both infrasonic frequency and audio frequency acoustic emissions from lightning. Preliminary results show that

  6. 43 CFR 3741.2 - Preference mining locations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Preference mining locations. 3741.2... DEVELOPMENT Claims, Locations and Patents § 3741.2 Preference mining locations. The Act in section 3(a) and (b... act, as limited in subsection (b) of this section 3, the right to locate mining claims upon the lands...

  7. Experiences with information locator services

    USGS Publications Warehouse

    Christian, E.

    1999-01-01

    Over the last few years, governments and other organizations have been using new technologies to create networked Information Locator Services that help people find information resources. These services not only enhance access to information, but also are designed to support fundamental information policy principles. This article relates experiences in developing and promoting services interoperable with the Global Information Locator Service standard that has now been adopted and promoted in many forums worldwide. The article describes sample implementations and touches on the strategic choices made in public policy, standards, and technology. Ten recommendations are offered for successful implementation of an Information Locator Service. Published by Elsevier Science Ltd. All rights reserved.

  8. Cold War Geopolitics: Embassy Locations.

    ERIC Educational Resources Information Center

    Vogeler, Ingolf

    1995-01-01

    Asserts that the geopolitics of the Cold War can be illustrated by the diplomatic ties among countries, particularly the superpowers and their respective allies. Describes a classroom project in which global patterns of embassy locations are examined and compared. Includes five maps and a chart indicating types of embassy locations. (CFR)

  9. Wi-Fi real time location systems

    NASA Astrophysics Data System (ADS)

    Doll, Benjamin A.

    This thesis objective was to determine the viability of utilizing an untrained Wi-Fi. real time location system as a GPS alternative for indoor environments. Background. research showed that GPS is rarely able to penetrate buildings to provide reliable. location data. The benefit of having location information in a facility and how they might. be used for disaster or emergency relief personnel and their resources motivated this. research. A building was selected with a well-deployed Wi-Fi infrastructure and its. untrained location feature was used to determine the distance between the specified. test points and the system identified location. It was found that the average distance. from the test point throughout the facility was 14.3 feet 80% of the time. This fell within. the defined viable range and supported that an untrained Wi-Fi RTLS system could be a. viable solution for GPS's lack of availability indoors.

  10. A complete denture impression technique survey of postdoctoral prosthodontic programs in the United States.

    PubMed

    Mehra, Mamta; Vahidi, Farhad; Berg, Robert W

    2014-06-01

    The purpose of the study was to survey program directors of postdoctoral prosthodontic programs in the United States regarding their programs' complete denture impression techniques. The key objectives of the survey were to identify the current trends in complete denture impression making and to determine which techniques and materials are taught in US postdoctoral prosthodontic programs. An online survey was sent to all program directors of US postdoctoral prosthodontic programs. The survey comprised two sections: preliminary impressions and final impressions. The survey contained 22 questions that would take approximately 5 minutes to complete. All responses remained anonymous throughout the survey. The response rate for the survey was 87%. A majority of the programs did not separately border mold the tray prior to making the preliminary impressions (82%). The impression material of choice for the preliminary impression was irreversible hydrocolloid (88%). Selective pressure was the predominantly used impression philosophy (80%). All programs border molded the custom tray, and 95% recorded the borders in sections. The material of choice for border molding the custom tray was modeling plastic impression compound (71%). The most commonly used impression material for the final impressions was polyvinylsiloxane (PVS) (42%), and the second most commonly used impression material was polysulphide (32%). The most common technique for locating the posterior palatal seal was marking intraorally and transferring onto the final impression (65%). Most programs routinely advised their patients not to wear their existing dentures for at least 24 hours before the final impressions were made (83%). Based on the results of this study, the following conclusions can be drawn: (1) The most commonly used material for the preliminary impression was irreversible hydrocolloid and for the final impression was PVS. (2) Modeling plastic impression compound was used by most programs to

  11. Comparing methods for Earthquake Location

    NASA Astrophysics Data System (ADS)

    Turkaya, Semih; Bodin, Thomas; Sylvander, Matthieu; Parroucau, Pierre; Manchuel, Kevin

    2017-04-01

    There are plenty of methods available for locating small magnitude point source earthquakes. However, it is known that these different approaches produce different results. For each approach, results also depend on a number of parameters which can be separated into two main branches: (1) parameters related to observations (number and distribution of for example) and (2) parameters related to the inversion process (velocity model, weighting parameters, initial location etc.). Currently, the results obtained from most of the location methods do not systematically include quantitative uncertainties. The effect of the selected parameters on location uncertainties is also poorly known. Understanding the importance of these different parameters and their effect on uncertainties is clearly required to better constrained knowledge on fault geometry, seismotectonic processes and at the end to improve seismic hazard assessment. In this work, realized in the frame of the SINAPS@ research program (http://www.institut-seism.fr/projets/sinaps/), we analyse the effect of different parameters on earthquakes location (e.g. type of phase, max. hypocentral separation etc.). We compare several codes available (Hypo71, HypoDD, NonLinLoc etc.) and determine their strengths and weaknesses in different cases by means of synthetic tests. The work, performed for the moment on synthetic data, is planned to be applied, in a second step, on data collected by the Midi-Pyrénées Observatory (OMP).

  12. [Rare location of arachnoid cysts. Extratemporal cysts].

    PubMed

    Martinez-Perez, Rafael; Hinojosa, José; Pascual, Beatriz; Panaderos, Teresa; Welter, Diego; Muñoz, María J

    2016-01-01

    The therapeutic management of arachnoid cysts depends largely on its location. Almost 50% of arachnoid cysts are located in the temporal fossa-Sylvian fissure, whereas the other half is distributed in different locations, sometimes exceptional. Under the name of infrequent location arachnoid cysts, a description is presented of those composed of 2 sheets of arachnoid membrane, which are not located in the temporal fossa, and are primary or congenital. Copyright © 2015 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  13. Alternative Locations for School Buildings.

    ERIC Educational Resources Information Center

    Earthman, Glen I.

    1999-01-01

    School systems in urbanized or built-up areas have difficulties locating suitable sites for new buildings. Examples of the use of space in alternative locations include the Parkway Program in Philadelphia; the Work Place School in Alberta, Canada; the Metropolitan Learning Alliance in Minnesota; and the Schoolhouse Boat in Vienna, Austria. (MLF)

  14. Preferred practice location at medical school commencement strongly determines graduates' rural preferences and work locations.

    PubMed

    Herd, Marie S; Bulsara, Max K; Jones, Michael P; Mak, Donna B

    2017-02-01

    To identify factors influencing whether Australian medical graduates prefer to, or actually, work rurally. Secondary analysis of longitudinal data from Medical Schools Outcomes Database (MSOD) using univariate and multivariate logistic regression. Twenty Australian medical schools. Australian or New Zealand citizens and Australian permanent residents who completed MSOD questionnaires between 2006 and 2013. Preferred and actual work locations 1 (PGY1) and 3 (PGY3) years postgraduation. Of 20 784 participants, 4028 completed a PGY1 or PGY3 questionnaire. Self-reported preference for rural practice location at medical school commencement was the most consistent independent predictor of whether a graduate would have a rural location preference at PGY1 (odds ratio (OR) 6.07, 95% confidence interval (CI) 4.91-7.51) and PGY3 (OR 7.95, 95% CI 4.93-12.84), and work rurally during PGY1 (OR 1.38, 95% CI 1.01-1.88) and PGY3 (OR 1.86, 95% CI 1.30-2.64). The effect of preferred practice location at medical school commencement is independent of, and enhances the effect of, rural background. Graduates of graduate-entry programs or with dependent children were less likely to have worked rurally during PGY1 and PGY3 respectively. The most consistent factor associated with rural preferences and work location was students' preferred location of practice at medical school commencement; this association is independent of, and enhances the effect of, rural background. Better understanding of what determines rural preference at medical school commencement and its influence on rural workplace outcomes beyond PGY3 is required to inform Australian medical school selection policies and rural health curricula. © 2016 National Rural Health Alliance Inc.

  15. STS-28 Columbia, OV-102, Mission Specialist Adamson eating on middeck

    NASA Technical Reports Server (NTRS)

    1989-01-01

    On middeck, Mission Specialist (MS) James C. Adamson enjoys the rare opportunity of eating in a weightless environment as he flips a shrimp with a spoon. In the background is a second crewmember holding a meal tray assembly (food tray) and sleep restraints fastened to starboard wall.

  16. Amending greenroof soil with biochar to affect runoff water quantity and quality.

    PubMed

    Beck, Deborah A; Johnson, Gwynn R; Spolek, Graig A

    2011-01-01

    Numbers of greenroofs in urban areas continue to grow internationally; so designing greenroof soil to reduce the amount of nutrients in the stormwater runoff from these roofs is becoming essential. This study evaluated changes in extensive greenroof water discharge quality and quantity after adding biochar, a soil amendment promoted for its ability to retain nutrients in soils and increase soil fertility. Prototype greenroof trays with and without biochar were planted with sedum or ryegrass, with barren soil trays used as controls. The greenroof trays were subjected to two sequential 7.4cm/h rainfall events using a rain simulator. Runoff from the rain events was collected and evaluated. Trays containing 7% biochar showed increased water retention and significant decreases in discharge of total nitrogen, total phosphorus, nitrate, phosphate, and organic carbon. The addition of biochar to greenroof soil improves both runoff water quality and retention. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Orientation of handle for successful prosthetic treatment in patients with an anatomic compromise after a maxillectomy.

    PubMed

    Sumita, Yuka I; Hattori, Mariko; Elbashti, Mahmoud E; Taniguchi, Hisashi

    2017-05-01

    This clinical technique provides a key procedure for successful prosthetic treatment in patients with an anatomical compromise after a maxillectomy. When making a preliminary impression, the clinician must keep the handle of the stock tray parallel to the patient's interpupillary line extraorally to maintain the correct position of the tray and to make a record of the inclination of the occlusal plane. This simple consideration during this first step of making a preliminary impression can be an important guide for both dentists and dental technicians. Information about the correct positioning of the tray and the inclination of the occlusal plane obtained by using a stock tray handle will greatly reduce the stress experienced by dentists, dental technicians, and patients during the fabrication of the prosthesis and will ultimately lead to successful prosthetic treatment in patients with anatomic compromise resulting from a maxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. On locating steganographic payload using residuals

    NASA Astrophysics Data System (ADS)

    Quach, Tu-Thach

    2011-02-01

    Locating steganographic payload usingWeighted Stego-image (WS) residuals has been proven successful provided a large number of stego images are available. In this paper, we revisit this topic with two goals. First, we argue that it is a promising approach to locate payload by showing that in the ideal scenario where the cover images are available, the expected number of stego images needed to perfectly locate all load-carrying pixels is the logarithm of the payload size. Second, we generalize cover estimation to a maximum likelihood decoding problem and demonstrate that a second-order statistical cover model can be used to compute residuals to locate payload embedded by both LSB replacement and LSB matching steganography.

  19. Privacy-Aware Location Database Service for Granular Queries

    NASA Astrophysics Data System (ADS)

    Kiyomoto, Shinsaku; Martin, Keith M.; Fukushima, Kazuhide

    Future mobile markets are expected to increasingly embrace location-based services. This paper presents a new system architecture for location-based services, which consists of a location database and distributed location anonymizers. The service is privacy-aware in the sense that the location database always maintains a degree of anonymity. The location database service permits three different levels of query and can thus be used to implement a wide range of location-based services. Furthermore, the architecture is scalable and employs simple functions that are similar to those found in general database systems.

  20. Source Identification and Location Techniques

    NASA Technical Reports Server (NTRS)

    Weir, Donald; Bridges, James; Agboola, Femi; Dougherty, Robert

    2001-01-01

    Mr. Weir presented source location results obtained from an engine test as part of the Engine Validation of Noise Reduction Concepts program. Two types of microphone arrays were used in this program to determine the jet noise source distribution for the exhaust from a 4.3 bypass ratio turbofan engine. One was a linear array of 16 microphones located on a 25 ft. sideline and the other was a 103 microphone 3-D "cage" array in the near field of the jet. Data were obtained from a baseline nozzle and from numerous nozzle configuration using chevrons and/or tabs to reduce the jet noise. Mr. Weir presented data from two configurations: the baseline nozzle and a nozzle configuration with chevrons on both the core and bypass nozzles. This chevron configuration had achieved a jet noise reduction of 4 EPNdB in small scale tests conducted at the Glenn Research Center. IR imaging showed that the chevrons produced significant improvements in mixing and greatly reduced the length of the jet potential core. Comparison of source location data from the 1-D phased array showed a shift of the noise sources towards the nozzle and clear reductions of the sources due to the noise reduction devices. Data from the 3-D array showed a single source at a frequency of 125 Hz. located several diameters downstream from the nozzle exit. At 250 and 400 Hz., multiple sources, periodically spaced, appeared to exist downstream of the nozzle. The trend of source location moving toward the nozzle exit with increasing frequency was also observed. The 3-D array data also showed a reduction in source strength with the addition of chevrons. The overall trend of source location with frequency was compared for the two arrays and with classical experience. Similar trends were observed. Although overall trends with frequency and addition of suppression devices were consistent between the data from the 1-D and the 3-D arrays, a comparison of the details of the inferred source locations did show differences. A

  1. 46 CFR 199.178 - Marking of stowage locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Marking of stowage locations. 199.178 Section 199.178... locations. (a) Containers, brackets, racks, and other similar stowage locations for lifesaving equipment... that location. (b) If more than one device is stowed in a location, the number of devices stowed must...

  2. 75 FR 32143 - Submission of Electronic Documentation With Comailed and Copalletized Mailings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... efficiency in the processing of copalletized mailings. The Postal Service can accept piece-level electronic...-size pieces in trays, which include pieces to be incorporated within a copalletized mailing, to prepare... statements for payment at the consolidator site. Consolidators of letter-size pieces in trays will also be...

  3. Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases.

    PubMed

    Gaillard, Romain; Cerciello, Simone; Lustig, Sebastien; Servien, Elvire; Neyret, Philippe

    2017-04-01

    Total knee arthroplasty (TKA) malalignment may result in pain and limited range of motion. The present study assessed the influence of different surgeon's and patient's related factors on the post-operative tibial tray coronal alignment. The charts and the x-rays of a continuous prospective series of 1417 TKAs operated upon between 1987 and 2015 were retrospectively reviewed. The long-leg AP views were performed at two months post-op and the tibial mechanical angle of the tibial tray was measured. Three groups were defined: varus (≤87° n = 167), valgus (≥93° n = 55) and well alignment (88° to 92° n = 1195). The influence of several pre-operative and peri-operative factors was investigated: surgeon handedness and experience (junior or senior), previous tibial osteotomies, Ahlbäck stage of osteoarthritits, pre-operative alignment, height and weight, age at surgery, approach (medial, lateral or tibial tubercle osteotomy), generation of implants, tray fixation, size of the tray and stem lenght. Univariate then multivariate analysis were performed to find out any correlation. Multivariate analysis showed a strong correlation between varus alignment of the tibial tray and pre-operative varus of the lower limb (p = 0.037), increased BMI (p = 0.016) and operated side opposite to the dominant surgeon's arm (p = 0.006). In a similar way a strong correlation was found between valgus alignment and pre-operative valgus of the limb (p = 0.026). Poor alignment of the tibial tray after TKA was associated with pre-operative malalignment of the lower limb, increased BMI and an index knee which was opposite to surgeon's dominant arm.

  4. Trends in Attendance at Scoliosis Research Society Annual Meetings (SRS AM) and International Meeting on Advanced Spine Techniques (IMAST): Location, Location, Location.

    PubMed

    Chen, Foster; Cho, Woojin; Kim, Han Jo; Levine, David B

    2017-07-01

    Descriptive, respective. Although overall membership in Scoliosis Research Society (SRS) has grown over the years, we were curious to see the effects of changing event venue location and timing on conference attendance. Every year, the SRS hosts two major meetings: the Annual Meeting (SRS AM) in the autumn, and the International Meeting on Advanced Spine Techniques (IMAST) in the summer. Sites have alternated from within and outside North America. Often, these meetings have also overlapped with several holidays in certain countries. This was an observational study of attendance from past SRS AM and IMAST meetings. Fourteen years of AM and 8 years of IMAST data were made available from the SRS. Participation based on delegate type and countries were tallied. Details from the 10 most represented nations and host nations per year were also tallied, and their national holidays were reviewed for overlaps with the AM. Membership in AM and IMAST increased from 820 in 2003 to 1,323 in 2016. Attendance at the AM has increased, whereas attendance at IMAST has declined, even after adjusting for membership size. Trends in participation were highly influenced by location. Participation by attendees from the host continent, and especially the host country, is generally high. The negative impact of distant meetings is profoundly seen with North Americans, whereas the positive impact of a nearby meeting was mostly clearly demonstrated by South Americans. Although SRS AM overlapped with holidays in China, Japan, or Korea nearly 50% of the time, this did not influence participation by delegates from these countries. Participation in the AM is highly influenced by location. Although North Americans represented the largest constituency, their presence was not needed to drive total attendance and was not sufficient to turn around the downturn in IMAST attendance. Choice of location can encourage the participation of delegates from the host and neighboring nations; through strategic

  5. KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, technicians on the floor watch as a tray is extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

    NASA Image and Video Library

    2003-09-24

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, technicians on the floor watch as a tray is extended from inside the Pressurized Module, or PM, part of the Japanese Experiment Module (JEM). The PM provides a shirt-sleeve environment in which astronauts on the International Space Station can conduct microgravity experiments. There are a total of 23 racks, including 10 experiment racks, inside the PM providing a power supply, communications, air conditioning, hardware cooling, water control and experiment support functions.

  6. Digital Map Requirements For Automatic Vehicle Location

    DOT National Transportation Integrated Search

    1998-12-01

    New Jersey Transit (NJT) is currently investigating acquisition of an automated vehicle locator (AVL) system. The purpose of the AVL system is to monitor the location of buses. Knowing the location of a bus enables the agency to manage the bus fleet ...

  7. Observation of Gigawatt-Class THz Pulses from a Compact Laser-Driven Particle Accelerator

    NASA Astrophysics Data System (ADS)

    Gopal, A.; Herzer, S.; Schmidt, A.; Singh, P.; Reinhard, A.; Ziegler, W.; Brömmel, D.; Karmakar, A.; Gibbon, P.; Dillner, U.; May, T.; Meyer, H.-G.; Paulus, G. G.

    2013-08-01

    We report the observation of subpicosecond terahertz (T-ray) pulses with energies ≥460μJ from a laser-driven ion accelerator, thus rendering the peak power of the source higher even than that of state-of-the-art synchrotrons. Experiments were performed with intense laser pulses (up to 5×1019W/cm2) to irradiate thin metal foil targets. Ion spectra measured simultaneously showed a square law dependence of the T-ray yield on particle number. Two-dimensional particle-in-cell simulations show the presence of transient currents at the target rear surface which could be responsible for the strong T-ray emission.

  8. First radiobiological results of LDEF-1 experiment A0015 with Arabidopsis seed embryos and Sordaria fungus spores

    NASA Astrophysics Data System (ADS)

    Zimmermann, M. W.; Gartenbach, K. E.; Kranz, A. R.

    1994-10-01

    This article highlights the first results of investigations on the general vitality and damage endpoints caused by cosmic ionizing radiation in dry, dormant plant seeds of the crucifer plant Arabidopsis thaliana (L.) Hennh. and the ascomycete Sordaria fimicola after 69 month stay in space. Wild-type and mutant gene marker lines were included in Free Flyer Biostack containers and exposed on earth and side tray of the LDEF-1 satellite. The damage in biological endpoints observed in the seeds increased in the side tray sample compared to the earth tray sample. For the ascospores we found different effects depending on the biological endpoints investigated for both expositions.

  9. First radiobiological results of LDEF-1 experiment A0015 with Arabidopsis seed embryos and Sordaria fungus spores.

    PubMed

    Zimmermann, M W; Gartenbach, K E; Kranz, A R

    1994-10-01

    This article highlights the first results of investigations on the general vitality and damage endpoints caused by cosmic ionizing radiation in dry, dormant plant seeds of the crucifer plant Arabidopsis thaliana (L.) Heynh. and the ascomycete Sordaria fimicola after 69 month stay in space. Wild-type and mutant gene marker lines were included in Free Flyer Biostack containers and exposed on earth and side tray of the LDEF-1 satellite. The damage in biological endpoints observed in the seeds increased in the side tray sample compared to the earth tray sample. For the ascospores we found different effects depending on the biological endpoints investigated for both expositions.

  10. Emitter location errors in electronic recognition system

    NASA Astrophysics Data System (ADS)

    Matuszewski, Jan; Dikta, Anna

    2017-04-01

    The paper describes some of the problems associated with emitter location calculations. This aspect is the most important part of the series of tasks in the electronic recognition systems. The basic tasks include: detection of emission of electromagnetic signals, tracking (determining the direction of emitter sources), signal analysis in order to classify different emitter types and the identification of the sources of emission of the same type. The paper presents a brief description of the main methods of emitter localization and the basic mathematical formulae for calculating their location. The errors' estimation has been made to determine the emitter location for three different methods and different scenarios of emitters and direction finding (DF) sensors deployment in the electromagnetic environment. The emitter has been established using a special computer program. On the basis of extensive numerical calculations, the evaluation of precise emitter location in the recognition systems for different configuration alignment of bearing devices and emitter was conducted. The calculations which have been made based on the simulated data for different methods of location are presented in the figures and respective tables. The obtained results demonstrate that calculation of the precise emitter location depends on: the number of DF sensors, the distances between emitter and DF sensors, their mutual location in the reconnaissance area and bearing errors. The precise emitter location varies depending on the number of obtained bearings. The higher the number of bearings, the better the accuracy of calculated emitter location in spite of relatively high bearing errors for each DF sensor.

  11. The locating ways of laying pipe manipulator

    NASA Astrophysics Data System (ADS)

    Wang, Dan; Li, Bin; Lei, DongLiang

    2010-01-01

    The laying pipe manipulator is a new equipment to lay concrete pipe. This kind of manipulator makes the work of laying pipes mechanized and automated. We report here a new laying pipe manipulator. The manipulator has 5 free degrees, and is driven by the hydraulic system. In the paper, one critical question of manipulator is studied: the locating ways of the manipulator to lay concrete pipe. During the process of laying concrete pipe, how to locate the manipulator is realized by the locating system of manipulator. The locating system consists of photoelectric target, laser producer, and computer. According to different construction condition, one or two or three photoelectric targets can be used. During the process of laying concrete pipe, if the interface of pipes are jointed together, and the other segment of pipe deviates from the pipe way, one target can be used, if the angle that the manipulator rotates around the holding pipe's axes is 0°, two targets can be used, three targets can be used at any site. In the paper, according to each locating way, the theory analysis is done. And the mathematical models of the manipulator moving from original position to goal position are obtained by different locating way. And the locating experiment was done. According to the experiment result, the work principle and mathematical models of different locating way was turned out to be well adopted for requirement, the mathematical model of different locating way supplies the basic control theory for the manipulator to lay and joint concrete pipe automatically.

  12. Printmaking for All Ages

    ERIC Educational Resources Information Center

    Mitchell, Annette W.

    2005-01-01

    Foam printing offers all ages and abilities a way to explore textures in the classroom and to develop personal creativity and imagination. Polystyrene foam trays (commonly known as "meat trays") are readily available, inexpensive, lightweight, portable, and receptive to a wide variety of surface treatments. The printmaking process requires only a…

  13. Commander Brand shaves in front of forward middeck lockers

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Commander Brand, wearing shorts, shaves in front of forward middeck lockers using personal hygiene mirror assembly (assy). Open modular locker single tray assy, Field Sequential (FS) crew cabin camera, communications kit assy mini headset (HDST) and HDST interface unit (HIU), personal hygiene kit, and meal tray assemblies appear in view.

  14. Stability of headspace volatiles in a ‘Fallglo’ tangerine juice matrix system at room temperature

    USDA-ARS?s Scientific Manuscript database

    Gas chromatography systems are usually equipped with autosamplers. Samples held in the autosampler tray can stay up to one day or longer at room temperature, if the tray is not equipped with a cooling mechanism. The objective of this research was to determine if holding samples at room temperature i...

  15. A Distance Bounding Protocol for Location-Cloaked Applications

    PubMed Central

    Molina-Martínez, Cristián; Galdames, Patricio

    2018-01-01

    Location-based services (LBSs) assume that users are willing to release trustworthy and useful details about their whereabouts. However, many location privacy concerns have arisen. For location privacy protection, several algorithms build a cloaking region to hide a user’s location. However, many applications may not operate adequately on cloaked locations. For example, a traditional distance bounding protocol (DBP)—which is run by two nodes called the prover and the verifier—may conclude an untight and useless distance between these two entities. An LBS (verifier) may use this distance as a metric of usefulness and trustworthiness of the location claimed by the user (prover). However, we show that if a tight distance is desired, traditional DBP can refine a user’s cloaked location and compromise its location privacy. To find a proper balance, we propose a location-privacy-aware DBP protocol. Our solution consists of adding some small delays before submitting any user’s response. We show that several issues arise when a certain delay is chosen, and we propose some solutions. The effectiveness of our techniques in balancing location refinement and utility is demonstrated through simulation. PMID:29701641

  16. A Distance Bounding Protocol for Location-Cloaked Applications.

    PubMed

    Molina-Martínez, Cristián; Galdames, Patricio; Duran-Faundez, Cristian

    2018-04-26

    Location-based services (LBSs) assume that users are willing to release trustworthy and useful details about their whereabouts. However, many location privacy concerns have arisen. For location privacy protection, several algorithms build a cloaking region to hide a user’s location. However, many applications may not operate adequately on cloaked locations. For example, a traditional distance bounding protocol (DBP)—which is run by two nodes called the prover and the verifier—may conclude an untight and useless distance between these two entities. An LBS (verifier) may use this distance as a metric of usefulness and trustworthiness of the location claimed by the user (prover). However, we show that if a tight distance is desired, traditional DBP can refine a user’s cloaked location and compromise its location privacy. To find a proper balance, we propose a location-privacy-aware DBP protocol. Our solution consists of adding some small delays before submitting any user’s response. We show that several issues arise when a certain delay is chosen, and we propose some solutions. The effectiveness of our techniques in balancing location refinement and utility is demonstrated through simulation.

  17. Wireless Damage Location Sensing System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Taylor, Bryant Douglas (Inventor)

    2012-01-01

    A wireless damage location sensing system uses a geometric-patterned wireless sensor that resonates in the presence of a time-varying magnetic field to generate a harmonic response that will experience a change when the sensor experiences a change in its geometric pattern. The sensing system also includes a magnetic field response recorder for wirelessly transmitting the time-varying magnetic field and for wirelessly detecting the harmonic response. The sensing system compares the actual harmonic response to a plurality of predetermined harmonic responses. Each predetermined harmonic response is associated with a severing of the sensor at a corresponding known location thereof so that a match between the actual harmonic response and one of the predetermined harmonic responses defines the known location of the severing that is associated therewith.

  18. 47 CFR 73.315 - FM transmitter location.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false FM transmitter location. 73.315 Section 73.315 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.315 FM transmitter location. (a) The transmitter location shall be chosen so that...

  19. 47 CFR 73.315 - FM transmitter location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false FM transmitter location. 73.315 Section 73.315 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.315 FM transmitter location. (a) The transmitter location shall be chosen so that...

  20. 48 CFR 452.247-70 - Delivery Location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Delivery Location. 452.247-70 Section 452.247-70 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE CLAUSES AND... Location. As prescribed in 447.302, insert a clause substantially as follows: Delivery Location (FEB 1988...

  1. Helicopter magnetic survey conducted to locate wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veloski, G.A.; Hammack, R.W.; Stamp, V.

    2008-07-01

    A helicopter magnetic survey was conducted in August 2007 over 15.6 sq mi at the Naval Petroleum Reserve No. 3’s (NPR-3) Teapot Dome Field near Casper, Wyoming. The survey’s purpose was to accurately locate wells drilled there during more than 90 years of continuous oilfield operation. The survey was conducted at low altitude and with closely spaced flight lines to improve the detection of wells with weak magnetic response and to increase the resolution of closely spaced wells. The survey was in preparation for a planned CO2 flood for EOR, which requires a complete well inventory with accurate locations formore » all existing wells. The magnetic survey was intended to locate wells missing from the well database and to provide accurate locations for all wells. The ability of the helicopter magnetic survey to accurately locate wells was accomplished by comparing airborne well picks with well locations from an intense ground search of a small test area.« less

  2. Continuous hydroponic wheat production using a recirculating system

    NASA Technical Reports Server (NTRS)

    Mackowiak, C. L.; Owens, L. P.; Hinkle, C. R.; Prince, R. P.

    1989-01-01

    Continuous crop production, where plants of various ages are growing simultaneously in a single recirculating nutrient solution, is a possible alternative to batch production in a Controlled Ecological Life Support System. A study was conducted at John F. Kennedy Space Center where 8 trays (0.24 sq m per tray) of Triticum aestivum L. Yecora Rojo were grown simultaneously in a growth chamber at 23 C, 65 percent relative humidity, 1000 ppm CO2, continuous light, with a continuous flow, thin film nutrient delivery system. The same modified Hoagland nutrient solution was recirculated through the plant trays from an 80 L reservoir throughout the study. It was maintained by periodic addition of water and nutrients based on chemical analyses of the solution. The study was conducted for 216 days, during which 24 trays of wheat were consecutively planted (one every 9 days), 16 of which were grown to maturity and harvested. The remaining 8 trays were harvested on day 216. Grain yields averaged 520 g m(exp -2), and had an average edible biomass of 32 percent. Consecutive yields were unaffected by nutrient solution age. It was concluded that continual wheat production will work in this system over an extended period of time. Certain micronutrient deficiencies and toxicities posed problems and must be addressed in future continuous production systems.

  3. Smart Location Database - Service

    EPA Pesticide Factsheets

    The Smart Location Database (SLD) summarizes over 80 demographic, built environment, transit service, and destination accessibility attributes for every census block group in the United States. Future updates to the SLD will include additional attributes which summarize the relative location efficiency of a block group when compared to other block groups within the same metropolitan region. EPA also plans to periodically update attributes and add new attributes to reflect latest available data. A log of SLD updates is included in the SLD User Guide. See the user guide for a full description of data sources, data currency, and known limitations: https://edg.epa.gov/data/Public/OP/SLD/SLD_userguide.pdf

  4. Smart Location Database - Download

    EPA Pesticide Factsheets

    The Smart Location Database (SLD) summarizes over 80 demographic, built environment, transit service, and destination accessibility attributes for every census block group in the United States. Future updates to the SLD will include additional attributes which summarize the relative location efficiency of a block group when compared to other block groups within the same metropolitan region. EPA also plans to periodically update attributes and add new attributes to reflect latest available data. A log of SLD updates is included in the SLD User Guide. See the user guide for a full description of data sources, data currency, and known limitations: https://edg.epa.gov/data/Public/OP/SLD/SLD_userguide.pdf

  5. 14 CFR 125.53 - Flight locating requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Flight locating requirements. 125.53... and Miscellaneous Requirements § 125.53 Flight locating requirements. (a) Each certificate holder must have procedures established for locating each flight for which an FAA flight plan is not filed that— (1...

  6. 14 CFR 125.53 - Flight locating requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Flight locating requirements. 125.53... and Miscellaneous Requirements § 125.53 Flight locating requirements. (a) Each certificate holder must have procedures established for locating each flight for which an FAA flight plan is not filed that— (1...

  7. 14 CFR 125.53 - Flight locating requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Flight locating requirements. 125.53... and Miscellaneous Requirements § 125.53 Flight locating requirements. (a) Each certificate holder must have procedures established for locating each flight for which an FAA flight plan is not filed that— (1...

  8. 14 CFR 125.53 - Flight locating requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Flight locating requirements. 125.53... and Miscellaneous Requirements § 125.53 Flight locating requirements. (a) Each certificate holder must have procedures established for locating each flight for which an FAA flight plan is not filed that— (1...

  9. 24 CFR 203.40 - Location of property.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Location of property. 203.40 Section 203.40 Housing and Urban Development Regulations Relating to Housing and Urban Development... § 203.40 Location of property. The mortgaged property shall be located within the United States, Puerto...

  10. 46 CFR 181.520 - Installation and location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Installation and location. 181.520 Section 181.520... TONS) FIRE PROTECTION EQUIPMENT Portable Fire Extinguishers § 181.520 Installation and location... the space being protected. The installation and location must be to the satisfaction of the Officer in...

  11. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable locating equipment. 15.213 Section 15.213 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Intentional Radiators § 15.213 Cable locating equipment. An intentional radiator used as cable locating equipment, as defined in § 15.3...

  12. Nonexposure Accurate Location K-Anonymity Algorithm in LBS

    PubMed Central

    2014-01-01

    This paper tackles location privacy protection in current location-based services (LBS) where mobile users have to report their exact location information to an LBS provider in order to obtain their desired services. Location cloaking has been proposed and well studied to protect user privacy. It blurs the user's accurate coordinate and replaces it with a well-shaped cloaked region. However, to obtain such an anonymous spatial region (ASR), nearly all existent cloaking algorithms require knowing the accurate locations of all users. Therefore, location cloaking without exposing the user's accurate location to any party is urgently needed. In this paper, we present such two nonexposure accurate location cloaking algorithms. They are designed for K-anonymity, and cloaking is performed based on the identifications (IDs) of the grid areas which were reported by all the users, instead of directly on their accurate coordinates. Experimental results show that our algorithms are more secure than the existent cloaking algorithms, need not have all the users reporting their locations all the time, and can generate smaller ASR. PMID:24605060

  13. Telemetry location error in a forested habitat

    USGS Publications Warehouse

    Chu, D.S.; Hoover, B.A.; Fuller, M.R.; Geissler, P.H.; Amlaner, Charles J.

    1989-01-01

    The error associated with locations estimated by radio-telemetry triangulation can be large and variable in a hardwood forest. We assessed the magnitude and cause of telemetry location errors in a mature hardwood forest by using a 4-element Yagi antenna and compass bearings toward four transmitters, from 21 receiving sites. The distance error from the azimuth intersection to known transmitter locations ranged from 0 to 9251 meters. Ninety-five percent of the estimated locations were within 16 to 1963 meters, and 50% were within 99 to 416 meters of actual locations. Angles with 20o of parallel had larger distance errors than other angles. While angle appeared most important, greater distances and the amount of vegetation between receivers and transmitters also contributed to distance error.

  14. Feature-location binding in 3D: Feature judgments are biased by 2D location but not position-in-depth

    PubMed Central

    Finlayson, Nonie J.; Golomb, Julie D.

    2016-01-01

    A fundamental aspect of human visual perception is the ability to recognize and locate objects in the environment. Importantly, our environment is predominantly three-dimensional (3D), but while there is considerable research exploring the binding of object features and location, it is unknown how depth information interacts with features in the object binding process. A recent paradigm called the spatial congruency bias demonstrated that 2D location is fundamentally bound to object features (Golomb, Kupitz, & Thiemann, 2014), such that irrelevant location information biases judgments of object features, but irrelevant feature information does not bias judgments of location or other features. Here, using the spatial congruency bias paradigm, we asked whether depth is processed as another type of location, or more like other features. We initially found that depth cued by binocular disparity biased judgments of object color. However, this result seemed to be driven more by the disparity differences than the depth percept: Depth cued by occlusion and size did not bias color judgments, whereas vertical disparity information (with no depth percept) did bias color judgments. Our results suggest that despite the 3D nature of our visual environment, only 2D location information – not position-in-depth – seems to be automatically bound to object features, with depth information processed more similarly to other features than to 2D location. PMID:27468654

  15. Feature-location binding in 3D: Feature judgments are biased by 2D location but not position-in-depth.

    PubMed

    Finlayson, Nonie J; Golomb, Julie D

    2016-10-01

    A fundamental aspect of human visual perception is the ability to recognize and locate objects in the environment. Importantly, our environment is predominantly three-dimensional (3D), but while there is considerable research exploring the binding of object features and location, it is unknown how depth information interacts with features in the object binding process. A recent paradigm called the spatial congruency bias demonstrated that 2D location is fundamentally bound to object features, such that irrelevant location information biases judgments of object features, but irrelevant feature information does not bias judgments of location or other features. Here, using the spatial congruency bias paradigm, we asked whether depth is processed as another type of location, or more like other features. We initially found that depth cued by binocular disparity biased judgments of object color. However, this result seemed to be driven more by the disparity differences than the depth percept: Depth cued by occlusion and size did not bias color judgments, whereas vertical disparity information (with no depth percept) did bias color judgments. Our results suggest that despite the 3D nature of our visual environment, only 2D location information - not position-in-depth - seems to be automatically bound to object features, with depth information processed more similarly to other features than to 2D location. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Subgingival delivery of oral debriding agents: a proof of concept.

    PubMed

    Dunlap, Tanya; Keller, Duane C; Marshall, Milton V; Costerton, J William; Schaudinn, Christoph; Sindelar, Betty; Cotton, John R

    2011-01-01

    This study is a proof of concept to determine the efficacy of a custom-fabricated tray in placing antimicrobial and debriding agents in the periodontal pockets of persons with active gingival infections. Localized subgingival delivery of antimicrobial and antibiotic agents is routinely employed as adjunctive therapy for the treatment and management ofperiopathogens associated with periodontal disease. Because these delivery techniques often face time constraints and impose temporary restrictions on patient brushing and flossing, a custom-formed prescription dental tray can be used to deliver and maintain medications in periodontal pockets between office visits and without brushing or flossing restrictions. The ability of this tray to maintain sufficient concentrations of medication in the periodontal pockets to have a therapeutic effect is evaluated here with theoretical modeling and practical application. Hydrogen peroxide is an oral debriding agent and oral wound cleanser with antimicrobial properties. The debriding effect of 1.7% hydrogen peroxide gel was tested in vitro on Streptococcus mutans biofilm using glass carriers for collection. Diffusion modeling tested the potential of the customized tray to place hydrogen peroxide gel into the sulcus in the presence of crevicular fluid flow. Changes in periodontal microflora with scanning electron microscopy analysis of in vivo paper point site sampling were analyzed before and after a thin ribbon of 1.7% hydrogen peroxide gel (approximately 0.7 gm) and a subtherapeutic dose (three drops) of Vibramycin (50 mg/5 ml) were placed via Perio Trays into periodontal pockets, ranging from 4-8 mm at daily prescribed intervals for two to five weeks. In vitro results indicate that 1.7% hydrogen peroxide gel breaks down the exopolysaccharide slime and cell walls ofS. mutans, and begins to debride the cells from glass carriers within 10 minutes. Diffusion modeling indicates that hydrogen peroxide can penetrate into the deeper

  17. 46 CFR 154.235 - Cargo tank location.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo tank location. 154.235 Section 154.235 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Ship Survival Capability and Cargo Tank Location § 154.235 Cargo tank location. (a) For type IG hulls, cargo...

  18. 46 CFR 154.235 - Cargo tank location.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo tank location. 154.235 Section 154.235 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Ship Survival Capability and Cargo Tank Location § 154.235 Cargo tank location. (a) For type IG hulls, cargo...

  19. 46 CFR 154.235 - Cargo tank location.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo tank location. 154.235 Section 154.235 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Ship Survival Capability and Cargo Tank Location § 154.235 Cargo tank location. (a) For type IG hulls, cargo...

  20. 18 CFR 701.6 - Location of office.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 2 2014-04-01 2014-04-01 false Location of office. 701.6 Section 701.6 Conservation of Power and Water Resources WATER RESOURCES COUNCIL COUNCIL ORGANIZATION Introduction § 701.6 Location of office. The Headquarters is located in the Washington, DC area. ...

  1. 18 CFR 701.6 - Location of office.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 2 2013-04-01 2012-04-01 true Location of office. 701.6 Section 701.6 Conservation of Power and Water Resources WATER RESOURCES COUNCIL COUNCIL ORGANIZATION Introduction § 701.6 Location of office. The Headquarters is located in the Washington, DC area. ...

  2. 18 CFR 701.6 - Location of office.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 2 2012-04-01 2012-04-01 false Location of office. 701.6 Section 701.6 Conservation of Power and Water Resources WATER RESOURCES COUNCIL COUNCIL ORGANIZATION Introduction § 701.6 Location of office. The Headquarters is located in the Washington, DC area. ...

  3. 18 CFR 701.6 - Location of office.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Location of office. 701.6 Section 701.6 Conservation of Power and Water Resources WATER RESOURCES COUNCIL COUNCIL ORGANIZATION Introduction § 701.6 Location of office. The Headquarters is located in the Washington, DC area. ...

  4. 18 CFR 701.6 - Location of office.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Location of office. 701.6 Section 701.6 Conservation of Power and Water Resources WATER RESOURCES COUNCIL COUNCIL ORGANIZATION Introduction § 701.6 Location of office. The Headquarters is located in the Washington, DC area. ...

  5. 46 CFR 154.235 - Cargo tank location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo tank location. 154.235 Section 154.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS... Survival Capability and Cargo Tank Location § 154.235 Cargo tank location. (a) For type IG hulls, cargo...

  6. 49 CFR 234.201 - Location of plans.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Location of plans. 234.201 Section 234.201..., Inspection, and Testing Maintenance Standards § 234.201 Location of plans. Plans required for proper maintenance and testing shall be kept at each highway-rail grade crossing warning system location. Plans shall...

  7. 25 CFR 286.7 - Location of enterprise.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ECONOMIC ENTERPRISES INDIAN BUSINESS DEVELOPMENT PROGRAM § 286.7 Location of enterprise. To be eligible for a grant an economic enterprise must be located on an Indian reservation or located where it makes or will make an economic contribution to a nearby...

  8. Systematic identification of high crash locations

    DOT National Transportation Integrated Search

    2001-05-01

    The objective of this project is to develop tools and procedures by which Iowa engineers can identify potentially hazardous roadway locations and designs, and to demonstrate the utility of these tools by developing candidate lists of high crash locat...

  9. Location of acoustic emission sources generated by air flow

    PubMed

    Kosel; Grabec; Muzic

    2000-03-01

    The location of continuous acoustic emission sources is a difficult problem of non-destructive testing. This article describes one-dimensional location of continuous acoustic emission sources by using an intelligent locator. The intelligent locator solves a location problem based on learning from examples. To verify whether continuous acoustic emission caused by leakage air flow can be located accurately by the intelligent locator, an experiment on a thin aluminum band was performed. Results show that it is possible to determine an accurate location by using a combination of a cross-correlation function with an appropriate bandpass filter. By using this combination, discrete and continuous acoustic emission sources can be located by using discrete acoustic emission sources for locator learning.

  10. Alternative Fuels Data Center: Biodiesel Fueling Station Locations

    Science.gov Websites

    Station Locations to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Fueling Station Locations on Google

  11. 27 CFR 25.21 - Restrictions on location.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Restrictions on location. 25.21 Section 25.21 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Location and Use of Brewery § 25.21 Restrictions on location. A...

  12. 27 CFR 25.21 - Restrictions on location.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Restrictions on location. 25.21 Section 25.21 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Location and Use of Brewery § 25.21 Restrictions on location. A...

  13. 27 CFR 25.21 - Restrictions on location.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Restrictions on location. 25.21 Section 25.21 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Location and Use of Brewery § 25.21 Restrictions on location. A...

  14. 27 CFR 25.21 - Restrictions on location.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Restrictions on location. 25.21 Section 25.21 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL BEER Location and Use of Brewery § 25.21 Restrictions on location. A...

  15. 27 CFR 25.21 - Restrictions on location.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Restrictions on location. 25.21 Section 25.21 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS BEER Location and Use of Brewery § 25.21 Restrictions on location. A...

  16. 24 CFR 203.38 - Location of dwelling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Location of dwelling. 203.38 Section 203.38 Housing and Urban Development Regulations Relating to Housing and Urban Development... § 203.38 Location of dwelling. At the time a mortgage is insured there must be located on the mortgaged...

  17. 30 CFR 71.401 - Location of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Location of facilities. 71.401 Section 71.401... Location of facilities. Bathhouses, change rooms, and sanitary flush toilet facilities shall be in a location convenient for the use of the miners. Where these facilities are designed to serve more than one...

  18. Optimizing deep hyperthermia treatments: are locations of patient pain complaints correlated with modelled SAR peak locations?

    NASA Astrophysics Data System (ADS)

    Canters, R. A. M.; Franckena, M.; van der Zee, J.; van Rhoon, G. C.

    2011-01-01

    During deep hyperthermia treatment, patient pain complaints due to heating are common when maximizing power. Hence, there exists a good rationale to investigate whether the locations of predicted SAR peaks by hyperthermia treatment planning (HTP) are correlated with the locations of patient pain during treatment. A retrospective analysis was performed, using the treatment reports of 35 patients treated with deep hyperthermia controlled by extensive treatment planning. For various SAR indicators, the average distance from a SAR peak to a patient discomfort location was calculated, for each complaint. The investigated V0.1 closest (i.e. the part of the 0.1th SAR percentile closest to the patient complaint) performed the best, and leads to an average distance between the SAR peak and the complaint location of 3.9 cm. Other SAR indicators produced average distances that were all above 10 cm. Further, the predicted SAR peak location with V0.1 provides a 77% match with the region of complaint. The current study demonstrates that HTP is able to provide a global indication of the regions where hotspots during treatment will most likely occur. Further development of this technology is necessary in order to use HTP as a valuable toll for objective and advanced SAR steering. The latter is especially valid for applications that enable 3D SAR steering.

  19. Tray Pack Prototype Plant Design

    DTIC Science & Technology

    1986-06-01

    Creamed Corn o Eggs w/Ham o Blueberry Dessert o Chicken ala king o Cherry Dessert * Egg Loaf w/Mushrooms* o Potato Salad * Orange Nut Cake* * Cherry...Steak o Pork Slices w/Gravy o Turkey Sl.w/Gravy o Swedish Meatballs o Ham Slices o Beef Pot Roast o Franks in Brine o Spaghetti w/ Meatballs o...Beef Tips w/Gravy * Egg Loaf w/Cheese* o Beef and Macaroni o Escalloped Potat. o Spanish Rice 2 6w % % P EI, o Beans w/Pork o Macaroni Salad o

  20. First LOCSMITH locations of deep moonquakes

    NASA Astrophysics Data System (ADS)

    Hempel, S.; Knapmeyer, M.; Sens-Schönfelder, C.; Oberst, J.

    2008-09-01

    Introduction Several thousand seismic events were recorded by the Apollo seismic network from 19691977. Different types of events can be distinguished: meteoroid impacts, thermal quakes and internally caused moonquakes. The latter subdivide into shallow (100 to 300km) and deep moonquakes (700 to 1100km), which are by far the most common events. The deep quakes would be no immediate danger to inhabitated stations on the Earth's Moon because of their relatively low magnitude and great depth. However, they bear important information on lunar structure and evolution, and their distribution probably reflects their source mechanism. In this study, we reinvestigate location patterns of deep lunar quakes. LOCSMITH The core of this study is a new location method (LOCSMITH, [1]). This algorithm uses time intervals rather than time instants as input, which contain the dedicated arrival with probability 1. LOCSMITH models and compares theoretical and actual travel times on a global scale and uses an adaptive grid to search source locations compatible with all observations. The output is a set of all possible hypocenters for the considered region of repeating, tidally triggered moonquake activity, called clusters. The shape and size of these sets gives a better estimate of the location uncertainty than the formal standard deviations returned by classical methods. This is used for grading of deep moonquake clusters according to the currently available data quality. Classification of deep moonquakes As first step, we establish a reciprocal dependence of size and shape of LOCSMITH location clouds on number of arrivals. Four different shapes are recognized, listed here in an order corresponding to decreasing spatial resolution: 1. "Balls", which are well defined and relatively small types of sets resembling the commonly assumed error ellipsoid. These are found in the best cases with many observations. Locations in this shape are obtained for clusters 1, 18 or 33, these were already

  1. Providing Location Security in Vehicular Ad Hoc Networks

    ERIC Educational Resources Information Center

    Yan, Gongjun

    2010-01-01

    Location is fundamental information in Vehicular Ad-hoc Networks (VANETs). Almost all VANET applications rely on location information. Therefore it is of importance to ensure location information integrity, meaning that location information is original (from the generator), correct (not bogus or fabricated) and unmodified (value not changed). We…

  2. Alternative Fuels Data Center: Ethanol Fueling Station Locations

    Science.gov Websites

    Fueling Station Locations to someone by E-mail Share Alternative Fuels Data Center: Ethanol Fueling Station Locations on Facebook Tweet about Alternative Fuels Data Center: Ethanol Fueling Station Locations on Twitter Bookmark Alternative Fuels Data Center: Ethanol Fueling Station Locations on Google

  3. Simultaneous Multiple-Location Separation Control

    NASA Technical Reports Server (NTRS)

    Greenblatt, David (Inventor)

    2009-01-01

    A method of controlling a shear layer for a fluid dynamic body introduces first periodic disturbances into the fluid medium at a first flow separation location. Simultaneously, second periodic disturbances are introduced into the fluid medium at a second flow separation location. A phase difference between the first and second periodic disturbances is adjusted to control flow separation of the shear layer as the fluid medium moves over the fluid dynamic body.

  4. 10 CFR 13.32 - Location of hearing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Location of hearing. 13.32 Section 13.32 Energy NUCLEAR REGULATORY COMMISSION PROGRAM FRAUD CIVIL REMEDIES § 13.32 Location of hearing. (a) The hearing may be held... shall have the opportunity to present argument with respect to the location of the hearing. (c) The...

  5. 34 CFR 33.32 - Location of hearing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Location of hearing. 33.32 Section 33.32 Education Office of the Secretary, Department of Education PROGRAM FRAUD CIVIL REMEDIES ACT § 33.32 Location of... and the ALJ. (b) Each party must have the opportunity to present argument with respect to the location...

  6. 47 CFR 95.1107 - Authorized locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Authorized locations. 95.1107 Section 95.1107 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1107 Authorized locations. The...

  7. 47 CFR 95.1203 - Authorized locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Authorized locations. 95.1203 Section 95.1203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Medical Device Radiocommunication Service (MedRadio) § 95.1203 Authorized locations. MedRadio...

  8. Location and acquisition of objects in unpredictable locations. [a teleoperator system with a computer for manipulator control

    NASA Technical Reports Server (NTRS)

    Sword, A. J.; Park, W. T.

    1975-01-01

    A teleoperator system with a computer for manipulator control to combine the capabilities of both man and computer to accomplish a task is described. This system allows objects in unpredictable locations to be successfully located and acquired. By using a method of characterizing the work-space together with man's ability to plan a strategy and coarsely locate an object, the computer is provided with enough information to complete the tedious part of the task. In addition, the use of voice control is shown to be a useful component of the man/machine interface.

  9. 25 CFR 169.17 - Change of location.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false Change of location. 169.17 Section 169.17 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER RIGHTS-OF-WAY OVER INDIAN LANDS § 169.17 Change of location. If any change from the location described in the conveyance instrument is found to be...

  10. Protection of Location Privacy Based on Distributed Collaborative Recommendations

    PubMed Central

    Wang, Peng; Yang, Jing; Zhang, Jian-Pei

    2016-01-01

    In the existing centralized location services system structure, the server is easily attracted and be the communication bottleneck. It caused the disclosure of users’ location. For this, we presented a new distributed collaborative recommendation strategy that is based on the distributed system. In this strategy, each node establishes profiles of their own location information. When requests for location services appear, the user can obtain the corresponding location services according to the recommendation of the neighboring users’ location information profiles. If no suitable recommended location service results are obtained, then the user can send a service request to the server according to the construction of a k-anonymous data set with a centroid position of the neighbors. In this strategy, we designed a new model of distributed collaborative recommendation location service based on the users’ location information profiles and used generalization and encryption to ensure the safety of the user’s location information privacy. Finally, we used the real location data set to make theoretical and experimental analysis. And the results show that the strategy proposed in this paper is capable of reducing the frequency of access to the location server, providing better location services and protecting better the user’s location privacy. PMID:27649308

  11. Protection of Location Privacy Based on Distributed Collaborative Recommendations.

    PubMed

    Wang, Peng; Yang, Jing; Zhang, Jian-Pei

    2016-01-01

    In the existing centralized location services system structure, the server is easily attracted and be the communication bottleneck. It caused the disclosure of users' location. For this, we presented a new distributed collaborative recommendation strategy that is based on the distributed system. In this strategy, each node establishes profiles of their own location information. When requests for location services appear, the user can obtain the corresponding location services according to the recommendation of the neighboring users' location information profiles. If no suitable recommended location service results are obtained, then the user can send a service request to the server according to the construction of a k-anonymous data set with a centroid position of the neighbors. In this strategy, we designed a new model of distributed collaborative recommendation location service based on the users' location information profiles and used generalization and encryption to ensure the safety of the user's location information privacy. Finally, we used the real location data set to make theoretical and experimental analysis. And the results show that the strategy proposed in this paper is capable of reducing the frequency of access to the location server, providing better location services and protecting better the user's location privacy.

  12. Reduction and standardization of surgical instruments in pediatric inguinal hernia repair.

    PubMed

    Koyle, Martin A; AlQarni, Naif; Odeh, Rakan; Butt, Hissan; Alkahtani, Mohammed M; Konstant, Louis; Pendergast, Lisa; Koyle, Leah C C; Baker, G Ross

    2018-02-01

    To standardize and reduce surgical instrumentation by >25% within a 9-month period for pediatric inguinal hernia repair (PIHR), using "improvement science" methodology. We prospectively evaluated instruments used for PIHR in 56 consecutive cases by individual surgeons across two separate subspecialties, pediatric surgery (S) and pediatric urology (U), to measure actual number of instruments used compared with existing practice based on preference cards. Based on this evaluation, a single preference card was developed using only instruments that had been used in >50% of all cases. A subsequent series of 52 cases was analyzed to assess whether the new tray contained the ideal instrumentation. Cycle time (CT), to sterilize and package the instruments, and weights of the trays were measured before and after the intervention. A survey of operating room (OR) nurses and U and S surgeons was conducted before and after the introduction of the standardized tray to assess the impact and perception of standardization. Prior to creating the standardized tray, a U PIHR tray contained 96 instruments with a weight of 13.5 lbs, while the S set contained 51, weighing 11.2 lbs. The final standardized set comprised 28 instruments and weighed 7.8 lbs. Of 52 PIHRs performed after standardization, in three (6%) instances additional instruments were requested. CT was reduced from 11 to 8 min (U and S respectively) to <5 min for the single tray. Nurses and surgeons reported that quality, safety, and efficiency were improved, and that efforts should continue to standardize instrumentation for other common surgeries. Standardization of surgical equipment can be employed across disciplines with the potential to reduce costs and positively impact quality, safety, and efficiencies. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. Validation of a New Larval Rearing Unit for Aedes albopictus (Diptera: Culicidae) Mass Rearing

    PubMed Central

    Gilles, Jérémie R. L.; Bellini, Romeo

    2014-01-01

    The mosquito larval rearing unit developed at the Insect Pest Control Laboratory (IPCL) of the FAO/IAEA Joint Division was evaluated for its potential use for Aedes albopictus (Skuse, 1895) mass rearing in support of the development of a sterile insect technique (SIT) package for this species. The use of the mass rearing trays and rack did not adversely affect larval development, pupation and survival rates and allowed the management of large larval rearing colonies with reduced space requirements in comparison with classical individual trays. The effects of larval density, water temperature and diet composition on pupal production and size differentiation for sex separation efficacy were analyzed for individual mass rearing trays as well as multiple trays stacked within the dedicated rack unit. Best results were obtained using eighteen thousand larvae per tray at a density of 3 larvae per ml of deionized water at a temperature of 28°C on a diet consisting of 50% tuna meal, 36% bovine liver powder, 14% brewer's yeast and, as an additive, 0.2 gr of Vitamin Mix per 100 ml of diet solution. Pupae were harvested on the sixth day from larval introduction at L1 stage and males were separated out by the use of a 1400 µm sieve with 99.0% accuracy with a recovery rate of ca. 25% of the total available males. With the use of this larval rearing unit, an average production of 100,000 male pupae per week can be achieved in just 2 square meter of laboratory space. Compared to previous laboratory rearing method, the same pupal production and sex separation efficacy could only be achieved by use of ca. 200 plastic trays which required the space of two 5 square meter climatic-controlled rooms. PMID:24647347

  14. Earthquake location in island arcs

    USGS Publications Warehouse

    Engdahl, E.R.; Dewey, J.W.; Fujita, K.

    1982-01-01

    A comprehensive data set of selected teleseismic P-wave arrivals and local-network P- and S-wave arrivals from large earthquakes occurring at all depths within a small section of the central Aleutians is used to examine the general problem of earthquake location in island arcs. Reference hypocenters for this special data set are determined for shallow earthquakes from local-network data and for deep earthquakes from combined local and teleseismic data by joint inversion for structure and location. The high-velocity lithospheric slab beneath the central Aleutians may displace hypocenters that are located using spherically symmetric Earth models; the amount of displacement depends on the position of the earthquakes with respect to the slab and on whether local or teleseismic data are used to locate the earthquakes. Hypocenters for trench and intermediate-depth events appear to be minimally biased by the effects of slab structure on rays to teleseismic stations. However, locations of intermediate-depth events based on only local data are systematically displaced southwards, the magnitude of the displacement being proportional to depth. Shallow-focus events along the main thrust zone, although well located using only local-network data, are severely shifted northwards and deeper, with displacements as large as 50 km, by slab effects on teleseismic travel times. Hypocenters determined by a method that utilizes seismic ray tracing through a three-dimensional velocity model of the subduction zone, derived by thermal modeling, are compared to results obtained by the method of joint hypocenter determination (JHD) that formally assumes a laterally homogeneous velocity model over the source region and treats all raypath anomalies as constant station corrections to the travel-time curve. The ray-tracing method has the theoretical advantage that it accounts for variations in travel-time anomalies within a group of events distributed over a sizable region of a dipping, high

  15. 12 CFR 905.3 - Location and business hours.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Location and business hours. (a) Location. All office units of the Finance Board are located at 1777 F... 12 Banks and Banking 7 2011-01-01 2011-01-01 false Location and business hours. 905.3 Section 905.3 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOUSING FINANCE BOARD ORGANIZATION AND...

  16. 12 CFR 905.3 - Location and business hours.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Location and business hours. (a) Location. All office units of the Finance Board are located at 1777 F... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Location and business hours. 905.3 Section 905.3 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOUSING FINANCE BOARD ORGANIZATION AND...

  17. 47 CFR 0.401 - Location of Commission offices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Location of Commission offices. 0.401 Section 0... Information General § 0.401 Location of Commission offices. The Commission maintains several offices and... locations. (1) The main office of the Commission is located at 445 12th Street, SW., Washington, DC 20554...

  18. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  19. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  20. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  1. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  2. 12 CFR 905.3 - Location and business hours.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Location and business hours. 905.3 Section 905.3 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOUSING FINANCE BOARD ORGANIZATION AND... Location and business hours. (a) Location. All office units of the Finance Board are located at 1777 F...

  3. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  4. Machine Cleans And Degreases Without Toxic Solvents

    NASA Technical Reports Server (NTRS)

    Gurguis, Kamal S.; Higginson, Gregory A.

    1993-01-01

    Appliance uses hot water and biodegradable chemicals to degrease and clean hardware. Spray chamber essentially industrial-scale dishwasher. Front door tilts open, and hardware to be cleaned placed on basket-like tray. During cleaning process, basket-like tray rotates as high-pressure "V" jets deliver steam, hot water, detergent solution, and rust inhibitor as required.

  5. 47 CFR 22.1009 - Transmitter locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Transmitter locations. 22.1009 Section 22.1009 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES PUBLIC MOBILE SERVICES... zones specified in § 22.1007. Offshore stations must not transmit from locations within 241 kilometers...

  6. 46 CFR 76.50-10 - Location.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  7. 46 CFR 76.50-10 - Location.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Extinguishers and Semiportable Fire Extinguishing Systems, Arrangements and Details § 76.50-10 Location. (a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in... fire extinguishing systems Classification (see § 76.50-5) Quantity and location Safety area 1...

  8. 25 CFR 571.10 - Geographical location.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false Geographical location. 571.10 Section 571.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR COMPLIANCE AND ENFORCEMENT PROVISIONS MONITORING AND INVESTIGATIONS Subpoenas and Depositions § 571.10 Geographical location. The attendance of...

  9. 25 CFR 571.10 - Geographical location.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false Geographical location. 571.10 Section 571.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR COMPLIANCE AND ENFORCEMENT PROVISIONS MONITORING AND INVESTIGATIONS Subpoenas and Depositions § 571.10 Geographical location. The attendance of...

  10. 25 CFR 571.10 - Geographical location.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false Geographical location. 571.10 Section 571.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR COMPLIANCE AND ENFORCEMENT PROVISIONS MONITORING AND INVESTIGATIONS Subpoenas and Depositions § 571.10 Geographical location. The attendance of...

  11. 25 CFR 571.10 - Geographical location.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false Geographical location. 571.10 Section 571.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR COMPLIANCE AND ENFORCEMENT PROVISIONS MONITORING AND INVESTIGATIONS Subpoenas and Depositions § 571.10 Geographical location. The attendance of...

  12. 22 CFR 1300.6 - Office location.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Office location. 1300.6 Section 1300.6 Foreign Relations MILLENNIUM CHALLENGE CORPORATION ORGANIZATION AND FUNCTIONS OF THE MILLENNIUM CHALLENGE CORPORATION § 1300.6 Office location. The principal offices of the Millennium Challenge Corporation are...

  13. 46 CFR 169.662 - Hazardous locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Hazardous locations. 169.662 Section 169.662 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and Electrical Electrical § 169.662 Hazardous locations. Electrical equipment must not be...

  14. 14 CFR 1209.403 - Organizational location.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Organizational location. 1209.403 Section 1209.403 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION BOARDS AND COMMITTEES Inventions and Contributions Board § 1209.403 Organizational location. The Board is established within the...

  15. 25 CFR 571.10 - Geographical location.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Geographical location. 571.10 Section 571.10 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR COMPLIANCE AND ENFORCEMENT PROVISIONS MONITORING AND INVESTIGATIONS Subpoenas and Depositions § 571.10 Geographical location. The attendance of...

  16. 47 CFR 95.1505 - Authorized locations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Authorized locations. 95.1505 Section 95.1505 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO... locations. Operation of DSRCS On-Board Units is authorized anywhere CB station operation is permitted under...

  17. 47 CFR 101.129 - Transmitter location.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Transmitter location. 101.129 Section 101.129 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.129 Transmitter location. (a) The applicant must determine, prior to...

  18. 47 CFR 101.129 - Transmitter location.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transmitter location. 101.129 Section 101.129 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.129 Transmitter location. (a) The applicant must determine, prior to...

  19. Method of locating underground mines fires

    DOEpatents

    Laage, Linneas; Pomroy, William

    1992-01-01

    An improved method of locating an underground mine fire by comparing the pattern of measured combustion product arrival times at detector locations with a real time computer-generated array of simulated patterns. A number of electronic fire detection devices are linked thru telemetry to a control station on the surface. The mine's ventilation is modeled on a digital computer using network analysis software. The time reguired to locate a fire consists of the time required to model the mines' ventilation, generate the arrival time array, scan the array, and to match measured arrival time patterns to the simulated patterns.

  20. Development and application of a 3-D geometry/mass model for LDEF satellite ionizing radiation assessments

    NASA Technical Reports Server (NTRS)

    Colborn, B. L.; Armstrong, T. W.

    1992-01-01

    A computer model of the three dimensional geometry and material distributions for the LDEF spacecraft, experiment trays, and, for selected trays, the components of experiments within a tray was developed for use in ionizing radiation assessments. The model is being applied to provide 3-D shielding distributions around radiation dosimeters to aid in data interpretation, particularly in assessing the directional properties of the radiation exposure. Also, the model has been interfaced with radiation transport codes for 3-D dosimetry response predictions and for calculations related to determining the accuracy of trapped proton and cosmic ray environment models. The methodology is described used in developing the 3-D LDEF model and the level of detail incorporated. Currently, the trays modeled in detail are F2, F8, and H12 and H3. Applications of the model which are discussed include the 3-D shielding distributions around various dosimeters, the influence of shielding on dosimetry responses, and comparisons of dose predictions based on the present 3-D model vs those from 1-D geometry model approximations used in initial estimates.