Sample records for uhmwpe knee components

  1. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

    PubMed

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

  2. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

    PubMed Central

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M.

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods. PMID:25506594

  3. Oxidation resistant peroxide cross-linked UHMWPE produced by blending and surface diffusion

    NASA Astrophysics Data System (ADS)

    Gul, Rizwan M.; Oral, Ebru; Muratoglu, Orhun K.

    2014-06-01

    Ultra-high molecular weight polyethylene (UHMWPE) has been widely used as acetabular cup in total hip replacement (THR) and tibial component in total knee replacement (TKR). Crosslinking of UHMWPE has been successful used to improve its wear performance leading to longer life of orthopedic implants. Crosslinking can be performed by radiation or organic peroxides. Peroxide crosslinking is a convenient process as it does not require specialized equipment and the level of crosslinking can be manipulated by changing the amount of peroxide added. However, there is concern about the long-term stability of these materials due to possible presence of by-products. Vitamin E has been successfully used to promote long-term oxidative stability of UHMWPE. In this study, UHMWPE has been crosslinked using organic peroxide in the presence of Vitamin E to produce an oxidation resistant peroxide crosslinked material. Crosslinking was performed both in bulk by mixing peroxide and resin, and only on the surface using diffusion of peroxides.The results show that UHMWPE can be crosslinked using organic peroxides in the presence of vitamin E by both methods. However, the level of crosslinking decreases with the increase in vitamin E content. The wear resistance increases with the increase in crosslink density, and oxidation resistance significantly increases due to the presence of vitamin E.

  4. Macrophage Response to UHMWPE Submitted to Accelerated Ageing in Hydrogen Peroxide

    PubMed Central

    Rocha, Magda F.G.; Mansur, Alexandra A.P.; Martins, Camila P.S.; Barbosa-Stancioli, Edel F.; Mansur, Herman S.

    2010-01-01

    Ultra-high molecular weight polyethylene (UHMWPE) has been the most commonly used bearing material in total joint arthroplasty. Wear and oxidation fatigue resistance of UHMWPE are regarded as two important properties to extend the longevity of knee prostheses. The present study investigated the accelerated ageing of UHMWPE in hydrogen peroxide highly oxidative chemical environment. The sliced samples of UHMWPE were oxidized in a hydrogen peroxide solution for 120 days with their total level of oxidation (Iox) characterized by Fourier Transformed Infrared Spectroscopy (FTIR). The potential inflammatory response, cell viability and biocompatibility of such oxidized UHMWPE systems were assessed by a novel biological in vitro assay based on the secretion of nitric oxide (NO) by activated murine macrophages with gamma interferon (IFN-γ) cytokine and lipopolysaccharide (LPS). Furthermore, macrophage morphologies in contact with UHMWPE oxidized surfaces were analyzed by cell spreading-adhesion procedure using scanning electron microscopy (SEM). The results have given significant evidence that the longer the period of accelerated aging of UHMWPE the higher was the macrophage inflammatory equivalent response based on NO secretion analysis. PMID:20721321

  5. [Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement].

    PubMed

    Veigl, D; Vavřík, P; Pokorný, D; Slouf, M; Pavlova, E; Landor, I

    2011-01-01

    The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface

  6. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE.

    PubMed

    Gomoll, A; Wanich, T; Bellare, A

    2002-11-01

    Radiation and chemical cross-linking of medical grade ultrahigh molecular weight polyethylene (UHMWPE) has recently been utilized in an effort to improve wear performance of total joint replacement components. However, reductions in mechanical properties with cross-linking are cause for concern regarding the use of cross-linked UHMWPE for high-stress applications such as in total knee replacement prostheses. In this study, the fracture behavior of radiation cross-linked UHMWPE was compared to that of uncross-linked UHMWPE. The Rice and Sorensen model that utilizes mechanical parameters obtained from uniaxial tensile and compact tension tests was used to calculate the steady state J-integral fracture toughness, Jss, for radiation cross-linked UHMWPE. Jss decreased monotonically with increase in radiation dose. UHMWPE exhibited tough, ductile tearing behavior with stable crack growth when it was cross-linked using a gamma radiation dose of 0-50 kGy. However, in cross-linked UHMWPE irradiated to a dose of 100 and 200 kGy, unstable fracture occurred spontaneously upon attaining the initial crack driving force, J1c. This indicates that a high degree of cross-linking is less desirable for high-stress applications in orthopaedic implants. However, a substantial increase in J1c, even at a low degree of cross-linking, suggests that a low degree of cross-linking may be beneficial for resistance to delamination and catastrophic failure, both of which require an initiation step for the fracture to propagate in the material. This mechanical test should, however, be considered along with fatigue tests and joint simulator testing before determination of an appropriate amount of cross-linking for total joint replacement prostheses that experience high stresses.

  7. Characterization and Accelerated Ageing of UHMWPE Used in Orthopedic Prosthesis by Peroxide

    PubMed Central

    Rocha, Magda; Mansur, Alexandra; Mansur, Herman

    2009-01-01

    Ultra-high molecular weight polyethylene (UHMWPE) has been the most commonly used bearing material in total joint arthroplasty. Wear and oxidation fatigue resistance of UHMWPE are regarded as two important mechanical properties to extend the longevity of knee prostheses. Though accelerated in vitro protocols have been developed to test the relative oxidation resistance of various types of UHMWPE, its mechanism is not accurately understood yet. Thus, in the present study an accelerated ageing of UHMWPE in hydrogen peroxide solution was performed and relative oxidation was extensively characterized by Fourier Transformed Infrared Spectroscopy (FTIR) spectroscopy and the morphological changes were analyzed by Scanning Electron Microscopy (SEM). Different chemical groups of UHMWPE associated with the degradation reaction were monitored for over 120 days in order to evaluate the possible oxidation mechanism(s) which may have occurred. The results have provided strong evidence that the oxidation mechanism is rather complex, and two stages with their own particular first-order kinetics reaction patterns have been clearly identified. Furthermore, hydrogen peroxide has proven to be an efficient oxidative medium to accelerate ageing of UHMWPE.

  8. Wear mechanisms and improvements of wear resistance in cobalt-chromium alloy femoral components in artificial total knee joints

    NASA Astrophysics Data System (ADS)

    Que, Like

    Wear is one of the major causes of artificial total knee arthroplasty (TKA) failure. Wear debris can cause adverse reactions to the surrounding tissue which can ultimately lead to loosening of the prosthesis. The wear behavior of UHMWPE tibial components have been studied extensively, but relatively little attention has been paid to the CoCrMo femoral component. The goal of the present study was to investigate the wear mechanisms of CoCrMo femoral components, to study the effect of CoCrMo alloy surface roughness on the wear of UHMWPE, and to determine the effect of heat treatments on the wear resistance of the CoCrMo implant alloys. The surface roughness of twenty-seven retrieved CoCrMo femoral components was analyzed. A multiple station wear testing machine and a wear fixture attached to an MTS 858 bionix system were built and used for in vitro wear studies of the CoCrMo/UHMWPE bearing couple. Solution and aging treatments were applied to the CoCrMo alloys. A white light interference surface profilometer (WLISP) and a scanning electron microscope (SEM) were used to measure the surface roughness and to study wear mechanisms of CoCrMo alloy. An optical microscope was used for alloy microstructure study. X-ray diffraction tests were performed to identify alloy phase transformation after aging. The micro-structure, hardness, and wear resistance of the alloys were studied. Surface roughness was used to quantify alloy wear, and the minimum number of surface roughness measurements required to obtain a reliable and repeatable characterization of surface roughness for a worn alloy surface was determined. The surfaces of the retrieved CoCrMo femoral components appeared to be damaged by metal particles embedded in the UHMWPE tibial component and metal-on-metal wear due to UHMWPE tibial component through-wear. Surface roughness of the femoral components was not correlated with patient age, weight, sex, or length of implantation. In vitro wear tests showed that when the Co

  9. [Intra-articular reinforcement of a partially torn anterior cruciate ligament (ACL) using newly developed UHMWPE biomaterial in combination with Hexalon ACL/PCL screws: ex-vivo mechanical testing of an animal knee model].

    PubMed

    Fedorová, P; Srnec, R; Pěnčík, J; Dvořák, M; Krbec, M; Nečas, A

    2015-01-01

    PURPOSE OF THE STUDY Recent trends in the experimental surgical management of a partial anterior cruciate ligament (ACL) rupture in animals show repair of an ACL lesion using novel biomaterials both for biomechanical reinforcement of a partially unstable knee and as suitable scaffolds for bone marrow stem cell therapy in a partial ACL tear. The study deals with mechanical testing of the newly developed ultra-high-molecular-weight polyethylene (UHMWPE) biomaterial anchored to bone with Hexalon biodegradable ACL/PCL screws, as a new possibility of intra-articular reinforcement of a partial ACL tear. MATERIAL AND METHODS Two groups of ex vivo pig knee models were prepared and tested as follows: the model of an ACL tear stabilised with UHMWPE biomaterial using a Hexalon ACL/PCL screw (group 1; n = 10) and the model of an ACL tear stabilised with the traditional, and in veterinary medicine used, extracapsular technique involving a monofilament nylon fibre, a clamp and a Securos bone anchor (group 2; n = 11). The models were loaded at a standing angle of 100° and the maximum load (N) and shift (mm) values were recorded. RESULTS In group 1 the average maximal peak force was 167.6 ± 21.7 N and the shift was on average 19.0 ± 4.0 mm. In all 10 specimens, the maximum load made the UHMWPE implant break close to its fixation to the femur but the construct/fixation never failed at the site where the material was anchored to the bone. In group 2, the average maximal peak force was 207.3 ± 49.2 N and the shift was on average 24.1 ± 9.5 mm. The Securos stabilisation failed by pullout of the anchor from the femoral bone in nine out of 11 cases; the monofilament fibre ruptured in two cases. CONCLUSIONS It can be concluded that a UHMWPE substitute used in ex-vivo pig knee models has mechanical properties comparable with clinically used extracapsular Securos stabilisation and, because of its potential to carry stem cells and bioactive substances, it can meet the requirements for

  10. Effect of e-beam sterilization on the in vivo performance of conventional UHMWPE tibial plates for total knee arthroplasty.

    PubMed

    Tone, Shine; Hasegawa, Masahiro; Pezzotti, Giuseppe; Puppulin, Leonardo; Sudo, Akihiro

    2017-06-01

    Although the introduction of highly cross-linked polyethylene is effective in reducing the amount of wear, there are still major concerns regarding the use of this material in total knee arthroplasty (TKA), essentially due to the reduction of fatigue resistance and toughness. Monitoring the in vivo performance of different types of UHMWPE is a much needed task to tackle the lack of information on which should be the most reliable choice for TKA. The present study was aimed at investigating the mid-term degradation of electron beam sterilized conventional UHMWPE tibial plates. Visual inspection enabled to grade the surface damage of 12 retrievals according to the Hood's score: the total wear damage correlates to the in vivo time (Spearman's ρ=0.681, p<0.05) and BMI (ρ=0.834, p<0.001). Surface degradation was less severe than that quantified in similar studies on γ-sterilized UHMWPE. Raman and infra-red spectroscopies were utilized to unfold the microstructural modifications. In the load zone, polyethylene whitened damage regions were noticed in the inserts implanted longer than 1year, in which oxidation index (OI) is clearly higher than 1 (max 8). The maximum OI (ρ=0.802, p<0.005) and α c (ρ=0.816, p<0.005) correlate to the implantation time in the load zone. The crystallinity increased along with the extent of oxidation. Concentration of absorbed species from synovial fluid is higher in the contact zone and correlates to maximum OI (Spearman's ρ=0.699, p=0.011). Absorption was promoted in the contact area by the mechanical action of the femoral counterpart and it exacerbated the oxidative degradation in retrievals with high concentration of absorbed species. In the non-load zone, mild but detectable oxidation was observed, probably due to free radicals trapped after sterilization. Although several clinical studies on retrieved tibial bearings have been published so far, monitoring and comparing the in vivo performance of different types of UHMWPE is still a

  11. Influence of heat treatment on structural, mechanical and wear properties of crosslinked UHMWPE.

    PubMed

    Chiesa, R; Moscatelli, M; Giordano, C; Siccardi, F; Cigada, A

    2004-01-01

    New crosslinked ultra high molecular weight polyethylenes (UHMWPEs) have recently been developed, characterized and introduced in clinical applications. UHMWPE cross-linking treatments are very promising for reducing osteolysis induced by wear debris. The irradiation type, gamma or beta, the dosage and the thermal treatment performed during or following the irradiation process are all factors affecting polyethylene wear resistance. Thermal stabilization treatments performed after or during the irradiation process at a temperature above melting point (i.e. >130 degrees C) have been proven to effectively remove the free radicals generated during irradiation from UHMWPE, but their effect on the mechanical properties of UHMWPE are not completely clear. In addition to wear rate reduction, maintaining good mechanical properties is fundamental aspect in designing the new generation of crosslinked UHMWPE for artificial load bearing materials, especially considering the application in total knee replacements. In this study, we investigated the influence of different stabilization treatments, performed after gamma irradiation, on structural, wear and mechanical properties of UHMWPE. We performed four different stabilization treatments, with different temperatures and cooling rates, on 100 kGy gamma irradiated UHMWPE. Structural properties of UHMWPE were assessed by differential scanning calorimetry (DSC). To assess the mechanical performance of the materials, uni-axial tensile tests were performed according to the ASTM D638 standard, bi-axial tension performance was evaluated by small punch tests (ASTM F2183-02), toughness resistance was evaluated by the Izod method (ASTM F648), and cold flow resistance was analysed by a dynamic compressive test. Evaluation of wear resistance was by a multidirectional pin-on-disk screening machine. Materials considered were in "aged" and "non-aged" conditions. Results confirmed that cross-linking greatly enhances UHMWPE wear resistance, but

  12. Cross-linked polyethylene does not reduce wear in total knee arthroplasty.

    PubMed

    Lasurt-Bachs, S; Torner, P; Maculé, F; Prats, E; Menéndez-García, F; Ríos-Guillermo, J; Torrents, A

    To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ 2 =0.19; P=.66) or rounded (χ 2 =1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  14. Peak Stress Intensity Factor Governs Crack Propagation Velocity In Crosslinked UHMWPE

    PubMed Central

    Sirimamilla, P. Abhiram; Furmanski, Jevan; Rimnac, Clare

    2013-01-01

    Ultra high molecular weight polyethylene (UHMWPE) has been successfully used as a bearing material in total joint replacement components. However, these bearing materials can fail as a result of in vivo static and cyclic loads. Crack propagation behavior in this material has been considered using the Paris relationship which relates fatigue crack growth rate, da/dN (mm/cycle) versus the stress intensity factor range, ΔK (Kmax-Kmin, MPa√m). However, recent work suggests that the crack propagation velocity of conventional UHMWPE is driven by the peak stress intensity (Kmax), not ΔK. The hypothesis of this study is that the crack propagation velocity of highly crosslinked and remelted UHMWPE is also driven by the peak stress intensity, Kmax, during cyclic loading, rather than by ΔK. To test this hypothesis, two highly crosslinked (65 kGy and 100 kGy) and remelted UHMWPE materials were examined. Frequency, waveform and R-ratio were varied between test conditions to determine the governing factor for fatigue crack propagation. It was found that the crack propagation velocity in crosslinked UHMWPE is also driven by Kmax and not ΔK, and is dependent on loading waveform and frequency in a predictable quasi-static manner. The current study supports that crack growth in crosslinked UHMWPE materials, even under cyclic loading conditions, can be described by a relationship between the velocity of crack growth, da/dt and the peak stress intensity, Kmax. The findings suggest that stable crack propagation can occur as a result of static loading only and this should be taken into consideration in design of UHMWPE total joint replacement components. PMID:23165898

  15. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners.

    PubMed

    Wannomae, Keith K; Christensen, Steven D; Freiberg, Andrew A; Bhattacharyya, Shayan; Harris, William H; Muratoglu, Orhun Kamil

    2006-03-01

    Irradiation decreases the wear of ultra-high molecular weight polyethylene (UHMWPE) but generates residual free radicals, precursors to long-term oxidation. Melting or annealing is used in quenching free radicals. We hypothesized that irradiated and once-annealed UHMWPE would oxidize while irradiated and melted UHMWPE would not, and that the oxidation in the former would increase wear. Acetabular liners were real-time aged by immersion in an aqueous environment that closely mimicked the temperature and oxygen concentration of synovial fluid. After 95 weeks of real-time aging, once-annealed components were oxidized; the melted components were not. The wear rate of the real-time aged irradiated and once-annealed components was higher than the literature reported values of other contemporary highly cross-linked UHMWPEs. Single annealing after irradiation used with terminal gamma sterilization may adversely affect the long-term oxidative stability of UHMWPE components.

  16. Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material

    PubMed Central

    Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar

    2015-01-01

    Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019

  17. Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty.

    PubMed

    Schindler, Oliver S

    2012-02-01

    Patellar and femoral component in total knee arthroplasty are inextricably linked as a functional unit. The configuration of this unit has been a matter of ongoing debate, and the myriad of different patellar and femoral components currently available reflect the lack of consensus with respect to the ideal design. One of the major challenges is to overcome the biomechanical disadvantages of a small contact area through which high contact pressures are transferred, making this mechanical construct the weakest part of the prosthetic knee. Contact areas are highly dependent on the congruency of the patellofemoral joint articulation, and are significantly smaller for dome shaped patellar components compared to those of more anatomic designs. However, when exposed to 3-dimensional movements, the contact areas of the dome shaped patella are significantly greater, indicating enhanced forgiveness regarding patellar malpositioning. Although contact stresses, a function of implant design and surface conformity, can reach levels far beyond the yield strength of UHMWPE, catastrophic failure of resurfaced patellar components, commonly seen in metal backed patellae, fashionable in the 1980s, has rarely been observed since. Although plastic deformation and wear of UHMWPE continue to represent a problem, in the absence of suitable alternatives polyethylene remains the bearing surface of choice. The appreciation of the consequences of the mechanical environment on the behaviour of the patellofemoral joint is of particular importance in the endeavour to develop knee replacement systems which provide satisfactory function together with clinical long-term success.

  18. Texturing of UHMWPE surface via NIL for low friction and wear properties

    NASA Astrophysics Data System (ADS)

    Suryadi Kustandi, Tanu; Choo, Jian Huei; Low, Hong Yee; Sinha, Sujeet K.

    2010-01-01

    Wear is a major obstacle limiting the useful life of implanted ultra-high molecular weight polyethylene (UHMWPE) components in total joint arthroplasty. It has been a continuous effort in the implant industry to reduce the frictional wear problem of UHMWPE by improving the structure, morphology and mechanical properties of the polymer. In this paper, a new paradigm that utilizes nanoimprint lithography (NIL) in producing textures on the surface of UHMWPE is proposed to efficiently improve the tribological properties of the polymer. Friction and wear experiments were conducted on patterned and controlled (non-patterned) UHMWPE surfaces using a commercial tribometer, mounted with a silicon nitride ball, under a dry-sliding condition with normal loads ranging from 60 to 200 mN. It has been shown that the patterned UHMWPE surface showed a reduction in the coefficient of friction between 8% and 35% as compared with the controlled (non-patterned) surface, depending on the magnitude of the normal load. Reciprocating wear experiments also showed that the presence of surface textures on the polymer resulted in lower wear depth and width, with minimal material transfer to the sliding surface.

  19. Viscoplastic crack initiation and propagation in crosslinked UHMWPE from clinically relevant notches up to 0.5mm radius.

    PubMed

    Sirimamilla, P Abhiram; Rimnac, Clare M; Furmanski, Jevan

    2018-01-01

    Highly crosslinked UHMWPE is now the material of choice for hard-on-soft bearing couples in total joint replacements. However, the fracture resistance of the polymer remains a design concern for increased longevity of the components in vivo. Fracture research utilizing the traditional linear elastic fracture mechanics (LEFM) or elastic plastic fracture mechanics (EPFM) approach has not yielded a definite failure criterion for UHMWPE. Therefore, an advanced viscous fracture model has been applied to various notched compact tension specimen geometries to estimate the fracture resistance of the polymer. Two generic crosslinked UHMWPE formulations (remelted 65kGy and remelted 100kGy) were analyzed in this study using notched test specimens with three different notch radii under static loading conditions. The results suggest that the viscous fracture model can be applied to crosslinked UHMWPE and a single value of critical energy governs crack initiation and propagation in the material. To our knowledge, this is one of the first studies to implement a mechanistic approach to study crack initiation and propagation in UHMWPE for a range of clinically relevant stress-concentration geometries. It is believed that a combination of structural analysis of components and material parameter quantification is a path to effective failure prediction in UHMWPE total joint replacement components, though additional testing is needed to verify the rigor of this approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Wettability of nano-epoxies to UHMWPE fibers.

    PubMed

    Neema, S; Salehi-Khojin, A; Zhamu, A; Zhong, W H; Jana, S; Gan, Y X

    2006-07-01

    Ultra high molecular weight polyethylene (UHMWPE) fibers have a unique combination of outstanding mechanical, physical, and chemical properties. However, as reinforcements for manufacturing high performance composite materials, UHMWPE fibers have poor wettability with most polymers. As a result, the interfacial bonding strength between the fibers and polymer matrices is very low. Recently, developing so-called nano-matrices containing reactive graphitic nanofibers (r-GNFs) has been proposed to promote the wetting of such matrices to certain types of fiber reinforcements. In this work, the wettability of UHMWPE fibers with different epoxy matrices including a nano-epoxy, and a pure epoxy was investigated. Systematic experimental work was conducted to determine the viscosity of the epoxies, the contact angle between the epoxies and the fibers. Also obtained are the surface energy of the fibers and the epoxies. The experimental results show that the wettability of the UHMWPE fibers with the nano-epoxy is much better than that of the UHMWPE fibers with the pure epoxy.

  1. Development and Characterization of UHMWPE Fiber-Reinforced Hydrogels For Meniscal Replacement

    NASA Astrophysics Data System (ADS)

    Holloway, Julianne Leigh

    Meniscal tears are the most common orthopedic injuries to the human body. The current treatment of choice, however, is a partial meniscectomy that leads to osteoarthritis proportional to the amount of tissue removed. As a result, there is a significant clinical need to develop materials capable of restoring the biomechanical contact stress distribution to the knee after meniscectomy and preventing the onset of osteoarthritis. In this work, a fiber-reinforced hydrogel-based synthetic meniscus was developed that allows for tailoring of the mechanical properties and molding of the implant to match the size, shape, and property distribution of the native tissue. Physically cross-linked poly(vinyl alcohol) (PVA) hydrogels were reinforced with ultrahigh molecular weight polyethylene (UHMWPE) fibers and characterized in compression (0.1-0.8 MPa) and tension (0.1-250 MPa) showing fine control over mechanical properties within the range of the human meniscus. Morphology and crystallinity analysis of PVA hydrogels showed increases in crystallinity and PVA densification, or phase separation, with freeze-thaw cycles. A comparison of freeze-thawed and aged, physically cross-linked hydrogels provided insight on both crystallinity and phase separation as mechanisms for PVA gelation. Results indicated both mechanisms independently contributed to hydrogel modulus for freeze-thawed hydrogels. In vitro swelling studies were performed using osmotic solutions to replicate the swelling pressure present in the knee. Minimal swelling was observed for hydrogels with a PVA concentration of 30-35 wt%, independently of hydrogel freeze-thaw cycles. This allows for independent tailoring of hydrogel modulus and pore structure using freeze-thaw cycles and swelling behavior using polymer concentration to match a wide range of properties needed for various soft tissue applications. The UHMWPE-PVA interface was identified as a significant weakness. To improve interfacial adhesion, a novel

  2. A Multidirectional Tribo-System: Wear of UHMWPE under Sliding, Rolling, and Rotation

    NASA Astrophysics Data System (ADS)

    Patten, Elias Wolfgang

    Total knee replacements (TKR) have become a successful surgical procedure for addressing end-stage osteoarthritis, with ultra-high molecular weight polyethylene and cobalt chrome alloy (UHMWPE/Co-Cr) serving as the bearing materials of choice for decades. However, more than 10% of TKRs fail and require revision surgery. The predominant challenge with UHMWPE is the particulate debris generated through wear-mediated processes; wear debris from the UHMWPE tibial bearing surface leading to loosening is still the main cause for post-fifth-year revisions. UHMWPE wear in hip arthroplasty has been linked to microstructural evolution at the surface from multidirectional sliding in the hip joint but little is known about how the microstructure responds to clinically relevant sliding conditions in the knee. This is likely because wear tests are typically performed under basic motion parameters with simplified geometry (pin-on-disk tests) while the knee has more complex kinematics: it is neither a ball-and-socket joint nor a simple hinge joint, but has 2D sliding, rolling/slip motion, and rotation. There is also disagreement over how to best quantify cross-shear and how to model how much wear it will cause. A custom multidirectional tribo-system was used to investigate the individual and combined effects of the different motions in TKR: 2D sliding, rolling, and rotation, for a total of eight separate kinematic conditions. The trends in wear rates and wear factors for these different motions were compared with many different definitions for magnitudes and ratios of cross-shear. Additionally, the wear surfaces were examined for wear mechanism and the microstructural changes in lamellae orientation for the different motions were analyzed. To mimic the tribological conditions of a condyle in a TKR, polished Co-Cr spheres were articulated against flat, smooth UHMWPE disks with physiologically relevant loading, speed, and lubrication conditions. The motion parameters were selected

  3. Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.

    PubMed

    Shen, Jie; Gao, Guorong; Liu, Xincai; Fu, Jun

    2015-03-01

    Radiation-crosslinked UHMWPE has been used for joint implants since the 1990s. Postirradiation remelting enhances oxidative stability, but with some loss in strength and toughness. Vitamin E-stabilized crosslinked UHMWPE has shown improved strength and stability as compared with irradiated and remelted UHMWPE. With more active phenolic hydroxyl groups, natural polyphenols are widely used in the food and pharmaceutical industries as potent stabilizers and could be useful for oxidative stability in crosslinked UHMWPE. We asked whether UHMWPE blended with polyphenols would (1) show higher oxidation resistance after radiation crosslinking; (2) preserve the mechanical properties of UHMWPE after accelerated aging; and (3) alter the wear resistance of radiation-crosslinked UHMWPE. The polyphenols, gallic acid and dodecyl gallate, were blended with medical-grade UHMWPE followed by consolidation and electron beam irradiation at 100 kGy. Radiation-crosslinked virgin and vitamin E-blended UHMWPEs were used as reference materials. The UHMWPEs were aged at 120 °C in air with oxidation levels analyzed by infrared spectroscopy. Tensile (n = 5 per group) and impact (n = 3 per group) properties before and after aging as per ASTM F2003 were evaluated. The wear rates were examined by pin-on-disc testing (n = 3 per group). The data were reported as mean ± SDs. Statistical analysis was performed by using Student's t-test for a two-tailed distribution with unequal variance for tensile and impact data obtained with n ≥ 3. A significant difference is defined with p < 0.05. The oxidation induction time of 100 kGy UHMWPE was prolonged to 144 hours with 0.05 wt% dodecyl gallate and 192 hours with 0.05 wt% gallic acid compared with 48 hours for 0.05 wt% vitamin E-blended UHMWPE. Accelerated aging of these polyphenol-blended UHMWPEs resulted in ultimate tensile strength of 50.4 ± 1.4 MPa and impact strength of 53 ± 5 kJ/m(2) for 100 kGy-irradiated UHMWPE with 0.05 wt% dodecyl gallate

  4. Multilayer porous UHMWPE scaffolds for bone defects replacement.

    PubMed

    Maksimkin, A V; Senatov, F S; Anisimova, N Yu; Kiselevskiy, M V; Zalepugin, D Yu; Chernyshova, I V; Tilkunova, N A; Kaloshkin, S D

    2017-04-01

    Reconstruction of the structural integrity of the damaged bone tissue is an urgent problem. UHMWPE may be potentially used for the manufacture of porous implants simulating as closely as possible the porous cancellous bone tissue. But the extremely high molecular weight of the polymer does not allow using traditional methods of foaming. Porous and multilayer UHMWPE scaffolds with nonporous bulk layer and porous layer that mimics cancellous bone architecture were obtained by solid-state mixing, thermopressing and washing in subcritical water. Structural and mechanical properties of the samples were studied. Porous UHMWPE samples were also studied in vitro and in vivo. The pores of UHMWPE scaffold are open and interconnected. Volume porosity of the obtained samples was 79±2%; the pore size range was 80-700μm. Strong connection of the two layers in multilayer UHMWPE scaffolds was observed with decreased number of fusion defects. Functionality of implants based on multilayer UHMWPE scaffolds is provided by the fixation of scaffolds in the bone defect through ingrowths of the connective tissue into the pores, which ensures the maintenance of the animals' mobility. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. An activated energy approach for accelerated testing of the deformation of UHMWPE in artificial joints.

    PubMed

    Galetz, Mathias Christian; Glatzel, Uwe

    2010-05-01

    The deformation behavior of ultrahigh molecular polyethylene (UHMWPE) is studied in the temperature range of 23-80 degrees C. Samples are examined in quasi-static compression, tensile and creep tests to determine the accelerated deformation of UHMWPE at elevated temperatures. The deformation mechanisms under compression load can be described by one strain rate and temperature dependent Eyring process. The activation energy and volume of that process do not change between 23 degrees C and 50 degrees C. This suggests that the deformation mechanism under compression remains stable within this temperature range. Tribological tests are conducted to transfer this activated energy approach to the deformation behavior under loading typical for artificial knee joints. While this approach does not cover the wear mechanisms close to the surface, testing at higher temperatures is shown to have a significant potential to reduce the testing time for lifetime predictions in terms of the macroscopic creep and deformation behavior of artificial joints. Copyright 2010. Published by Elsevier Ltd.

  6. Characterization of irradiated blends of alpha-tocopherol and UHMWPE.

    PubMed

    Oral, Ebru; Greenbaum, Evan S; Malhi, Arnaz S; Harris, William H; Muratoglu, Orhun K

    2005-11-01

    Adhesive/abrasive wear in ultra-high molecular weight polyethylene (UHMWPE) has been minimized by radiation cross-linking. Irradiation is followed by melting to eliminate residual free radicals and avoid long-term oxidative embrittlement. However, post-irradiation melting reduces the crystallinity of the polymer and hence its strength and fatigue resistance. We proposed an alternative to post-irradiation melting to be the incorporation of the antioxidant alpha-tocopherol into UHMWPE prior to consolidation. alpha-Tocopherol is known to react with oxygen and oxidized lipids, stabilizing them against further oxidative degradation reactions. We blended GUR 1050 UHMWPE resin powder with alpha-tocopherol at 0.1 and 0.3 wt% and consolidated these blends. Then we gamma-irradiated these blends to 100-kGy. We characterized the effect of alpha-tocopherol on the cross-linking efficiency, oxidative stability, wear behavior and mechanical properties of the blends. (I) The cross-link density of virgin, 0.1 and 0.3 wt% alpha-tocopherol blended, 100-kGy irradiated UHMWPEs were 175+/-19, 146+/-4 and 93+/-4 mol/m3, respectively. (II) Maximum oxidation indices for 100-kGy irradiated UHMWPE previously blended with 0, 0.1 and 0.3 wt% alpha-tocopherol that were subjected to accelerated aging at 80 degrees C in air for 5 weeks were 3.32, 0.09, and 0.05, respectively. (III) The pin-on-disc wear rates of 100-kGy irradiated UHMWPE previously blended with 0.1 and 0.3 wt% alpha-tocopherol that were subjected to accelerated aging at 80 degrees C in air for 5 weeks were 2.10+/-0.17 and 5.01+/-0.76 mg/million cycles, respectively. (IV) Both accelerated aged, alpha-tocopherol-blended 100-kGy irradiated UHMWPEs showed higher ultimate tensile strength, higher yield strength, and lower elastic modulus when compared to 100-kGy irradiated, virgin UHMWPE. These results showed that alpha-tocopherol-blended 100-kGy irradiated UHMWPEs were not cross-linked to the same extent as the 100-kGy irradiated

  7. In vivo degradation in modern orthopaedic UHMWPE bearings and structural characterization of a novel alternative UHMWPE material

    NASA Astrophysics Data System (ADS)

    Reinitz, Steven D.

    Ultra-high molecular weight polyethylene (UHMWPE) remains the most common bearing material for total joint arthroplasty. Advances in radiation cross-linking and other post-consolidation treatments have led to a rapid differentiation of polyethylene products on the market, with more than twenty unique materials currently being sold by the five largest orthopaedic manufacturers alone. Through oxidation, cross-link density, and free radical measurements, this work demonstrates for the first time that in vivo material degradation is occurring in cross-linked UHMWPE materials. Based on the rate of the reaction in certain materials, it is concluded that oxidative degradation may compromise the mechanical properties of the bearings in as few as ten years, potentially leading to early clinical failure of the devices. Using the knowledge gained from this work as well as previously published observations about UHMWPE oxidation, a two-mechanism model of oxidation is proposed that offers an explanation for the observed in vivo changes. From this model it is concluded that oxidative degradation is in part the result of in vivo chemical species. The two-mechanism model of oxidation suggests that different processing techniques for UHMWPE may reduce the risk of oxidative degradation. It is concluded that by avoiding any radiation cross-linking step, Equal Channel Angular Processing (ECAP) can produce UHMWPE materials with a reduced risk for in vivo oxidation while at the same time offering superior mechanical properties compared to commercially available UHMWPE materials, as well as similar wear behavior. Using dynamic mechanical analysis, the entanglement density in ECAP materials is quantified, and is related back to the ECAP processing parameters. The relationship between entanglement density and resultant material properties is established. The results will allow informed processing parameter selection for producing optimized materials for orthopaedics and other applications.

  8. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up

    PubMed Central

    2012-01-01

    Background Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis. PMID:22356935

  9. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up.

    PubMed

    Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka

    2012-02-22

    Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  10. Accelerated aging studies of UHMWPE. II. Virgin UHMWPE is not immune to oxidative degradation.

    PubMed

    Edidin, A A; Villarraga, M L; Herr, M P; Muth, J; Yau, S S; Kurtz, S M

    2002-08-01

    In Part I of this series, we showed that aging at elevated oxygen pressure is more successful at increasing the depth to which degradation occurs although it, too, generally causes greater degradation at the surface than at the subsurface. Therefore we hypothesized that thermal degradation alone, in the absence of free radicals, could be sufficient to artificially age UHMWPE in a manner analogous to natural aging. In the present study, virgin and air-irradiated UHMWPE (extruded GUR 1050 and compression-molded 1900) were aged up to 4 weeks at elevated oxygen pressure, and the mechanical behavior at the surface and subsurface was examined. All the materials were substantially degraded following 4 weeks of aging, but the spatial variations in the nonirradiated materials more closely mimicked the previously observed subsurface peak of degradation seen in naturally aged UHMWPE following irradiation in air. This aged material could provide a more realistic model for subsurface mechanical degradation, making it suitable for further mechanical testing in venues such as wear simulation. Copyright 2002 Wiley Periodicals, Inc.

  11. Mechanisms of plastic deformation in highly cross-linked UHMWPE for total hip components--the molecular physics viewpoint.

    PubMed

    Takahashi, Yasuhito; Shishido, Takaaki; Yamamoto, Kengo; Masaoka, Toshinori; Kubo, Kosuke; Tateiwa, Toshiyuki; Pezzotti, Giuseppe

    2015-02-01

    Plastic deformation is an unavoidable event in biomedical polymeric implants for load-bearing application during long-term in-vivo service life, which involves a mass transfer process, irreversible chain motion, and molecular reorganization. Deformation-induced microstructural alterations greatly affect mechanical properties and durability of implant devices. The present research focused on evaluating, from a molecular physics viewpoint, the impact of externally applied strain (or stress) in ultra-high molecular weight polyethylene (UHMWPE) prostheses, subjected to radiation cross-linking and subsequent remelting for application in total hip arthroplasty (THA). Two different types of commercial acetabular liners, which belong to the first-generation highly cross-linked UHMWPE (HXLPE), were investigated by means of confocal/polarized Raman microprobe spectroscopy. The amount of crystalline region and the spatial distribution of molecular chain orientation were quantitatively analyzed according to a combined theory including Raman selection rules for the polyethylene orthorhombic structure and the orientation distribution function (ODF) statistical approach. The structurally important finding was that pronounced recrystallization and molecular reorientation increasingly appeared in the near-surface regions of HXLPE liners with increasing the amount of plastic (compressive) deformation stored in the microstructure. Such molecular rearrangements, occurred in response to external strains, locally increase surface cross-shear (CS) stresses, which in turn trigger microscopic wear processes in HXLPE acetabular liners. Thus, on the basis of the results obtained at the molecular scale, we emphasize here the importance of minimizing the development of irrecoverable deformation strain in order to retain the pristine and intrinsically high wear performance of HXLPE components. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Wear studies of all UHMWPE couples under various bio-tribological conditions.

    PubMed

    Joyce, T J; Unsworth, A

    2004-01-01

    Wear tests were undertaken in which ultra high molecular weight polyethylene (UHMWPE) was rubbed against itself. Tests primarily employed a pin-on-plate wear test machine, with distilled water, Ringer solution and dilute bovine serum being used as the lubricants. Loads of 10N and 40N were employed, and some test pins had a rotational motion added. In all cases wear was high, with mean wear factors of up to 91 10 -6 mm3/Nm being measured, but the addition of rotation reduced the amount of material worn from the test plates. In the presence of bovine serum and under reciprocation only, pin wear was relatively low. With bovine serum as the lubricant, total mean wear factors for the UHMWPE couples were calculated to be in the range of 35 to 58 10-6mm3/Nm. Therefore the pin-on-plate tests showed that the choice of lubricant as well as the motion applied to the test pin had a significant influence on the wear volumes measured. A two-piece UHMWPE 'prosthesis' with matching hemispherical faces was fabricated and tested on a finger simulator. Distilled water was used as the lubricant and wear factors were found to be greater for the metacarpal component, 21 10 -6mm3/Nm, than the phalangeal component, 3 10-6mm3/Nm, after ten million cycles of testing. This result paralleled the greater wear seen by the plate than by the pin in the pin-on-plate tests under reciprocating motion. (Journal of Applied Biomaterials & Biomechanics 2004; 2: 29-34).

  13. Novel active stabilization technology in highly crosslinked UHMWPEs for superior stability

    NASA Astrophysics Data System (ADS)

    Oral, Ebru; Neils, Andrew L.; Wannomae, Keith K.; Muratoglu, Orhun K.

    2014-12-01

    Radiation cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is the bearing of choice in joint arthroplasty. The demands on the longevity of this polymer are likely to increase with the recently advancing deterioration of the performance of alternative metal-on-metal implants. Vitamin E-stabilized, cross-linked UHMWPEs are considered the next generation of improved UHMWPE bearing surfaces for improving the oxidation resistance of the polymer. It was recently discovered that in the absence of radiation-induced free radicals, lipids absorbed into UHMWPE from the synovial fluid can initiate oxidation and result in new free radical-mediated oxidation mechanisms. In the presence of radiation-induced free radicals, it is possible for the polymer to oxidize through both existing free radicals at the time of implantation and through newly formed free radicals in vivo. Thus, we showed that reducing the radiation-induced free radicals in vitamin E-stabilized UHMWPE would increase its oxidative stability and presumably lead to improved longevity. We describe mechanical annealing and warm irradiation of irradiated vitamin E blends as novel methods to eliminate 99% of radiation-induced free radicals without sacrificing crystallinity. These are significant improvements in the processing of highly cross-linked UHMWPE for joint implants with improved longevity.

  14. Accelerated aging studies of UHMWPE. I. Effect of resin, processing, and radiation environment on resistance to mechanical degradation.

    PubMed

    Edidin, A A; Herr, M P; Villarraga, M L; Muth, J; Yau, S S; Kurtz, S M

    2002-08-01

    The resin and processing route have been identified as potential variables influencing the mechanical behavior, and hence the clinical performance, of ultra-high molecular weight polyethylene (UHMWPE) orthopedic components. Researchers have reported that components fabricated from 1900 resin may oxidize to a lesser extent than components fabricated from GUR resin during shelf aging after gamma sterilization in air. Conflicting reports on the oxidation resistance for 1900 raise the question of whether resin or manufacturing method, or an interaction between resin and manufacturing method, influences the mechanical behavior of UHMWPE. We conducted a series of accelerated aging studies (no aging, aging in oxygen or in nitrogen) to systematically examine the influence of resin (GUR or 1900), manufacturing method (bulk compression molding or extrusion), and sterilization method (none, in air, or in nitrogen) on the mechanical behavior of UHMWPE. The small punch testing technique was used to evaluate the mechanical behavior of the materials, and Fourier transform infrared spectroscopy was used to characterize the oxidation in selected samples. Our study showed that the sterilization environment, aging condition, and specimen location (surface or subsurface) significantly affected the mechanical behavior of UHMWPE. Each of the three polyethylenes evaluated seem to degrade according to a similar pathway after artificial aging in oxygen and gamma irradiation in air. The initial ability of the materials to exhibit post-yield strain hardening was significantly compromised by degradation. In general, there were only minor differences in the aging behavior of molded and extruded GUR 1050, whereas the molded 1900 material seemed to degrade slightly faster than either of the 1050 materials. Copyright 2002 Wiley Periodicals, Inc.

  15. Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo.

    PubMed

    Utzschneider, Sandra; Becker, Fabian; Grupp, Thomas M; Sievers, Birte; Paulus, Alexander; Gottschalk, Oliver; Jansson, Volkmar

    2010-11-01

    Poly(ether ether ketone) (PEEK) and its composites are recognized as alternative bearing materials for use in arthroplasty because of their mechanical properties. The objective of this project was to evaluate the biological response of two different kinds of carbon fiber-reinforced (CFR) PEEK compared with ultra-high molecular weight polyethylene (UHMWPE) in vivo as a standard bearing material. Wear particles of the particulate biomaterials were injected into the left knee joint of female BALB/c mice. Assessment of the synovial microcirculation using intravital fluorescence microscopy as well as histological evaluation of the synovial layer were performed 7 days after particle injection. Enhanced leukocyte-endothelial cell interactions and an increase in functional capillary density as well as histological investigations revealed that all tested biomaterials caused significantly (P < 0.05) increased inflammatory reactions compared with control animals (injected with sterile phosphate-buffered saline), without any difference between the tested biomaterials (P > 0.05). These data suggest that wear debris of CFR-PEEK is comparable with UHMWPE in its biological activity. Therefore, CFR-PEEK represents an alternative bearing material because of its superior mechanical and chemical behavior without any increased biological activity of the wear particles, compared with a standard bearing material. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. The Influence Of Component Alignment On The Life Of Total Knee Prostheses

    NASA Astrophysics Data System (ADS)

    Bugariu, Delia; Bereteu, Liviu

    2012-12-01

    An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.

  17. Thermal Response of UHMWPE Materials in a Flash Flame Test Environment

    DTIC Science & Technology

    2014-11-13

    Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE

  18. The effect of accelerated aging on the wear of UHMWPE.

    PubMed

    Sakoda, H; Fisher, J; Lu, S; Buchanan, F

    2001-01-01

    Oxidative degradation of UHMWPE has been found to be a cause of elevated wear rate of the polymer in total joint replacement leading to failure of these devices. In order to evaluate long term stability of polymers, various accelerated aging methods have been developed. In this study, wear rates of shelf aged UHMWPE and "accelerated aged" UHMWPE were compared using a multi-directional pin-on-plate wear test machine in order to evaluate the effect of the accelerated aging on wear. Wear factors of the aged materials were found to depend on their density, which is a measure of oxidation level. Finally, accelerated aging was calibrated against shelf aging in terms of wear rate. Copyright 2001 Kluwer Academic Publishers

  19. Development of Ultra-High Molecular Weight Polyethylene (UHMWPE) Coating by Cold Spray Technique

    NASA Astrophysics Data System (ADS)

    Ravi, Kesavan; Ichikawa, Yuji; Deplancke, Tiana; Ogawa, Kazuhiro; Lame, Olivier; Cavaille, Jean-Yves

    2015-08-01

    Ultra-high molecular weight polyethylene or UHMWPE is an extremely difficult material to coat with, as it is rubbery and chemically very inert. The Cold Spray process appears to be a promising alternative processing technique but polymers are in general difficult to deposit using this method. So, attempts to develop UHMWPE coatings were made using a downstream injection cold spray technique incorporating a few modifications. A conventional cold spray machine yielded only a few deposited particles of UHMWPE on the substrate surface, but with some modifications in the nozzle geometry (especially the length and inner geometry) a thin coating of 45 μm on Al substrate was obtained. Moreover, experiments with the addition of fumed nano-alumina to the feedstock yielded a coating of 1-4 mm thickness on Al and polypropylene substrates. UHMWPE was seen to be melt crystallized during the coating formation, as can be seen from the differential calorimetry curves. Influence of nano-ceramic particles was explained by observing the creation of a bridge bond between UHMWPE particles.

  20. Effect of crosslinking UHMWPE on its tensile and compressive creep performance.

    PubMed

    Lewis, G; Carroll, M

    2001-01-01

    The in vitro quasi-static tensile and compressive creep properties of three sets of GUR 1050 ultra-high-molecular-weight polyethylene (UHMWPE) specimens were obtained. These sets were: control (as-received stock); "low-gamma" (specimens were crosslinked using gamma radiation, with a minimum dose of 5 Mrad); and "high-gamma" (specimens were crosslinked using gamma radiation, with a minimum dose of 15 Mrad). The % crystallinity (%C) and crosslink density (rho(x)) of the specimens in the three sets were also obtained. It was found that, in both tension and compression, crosslinking resulted in a significant depreciation in the creep properties, relative to control. The trend in the creep results is explained in terms of the impact of crosslinking on the polymer's %C and rho(x). The present results are in contrast to literature reports that show that crosslinking enhances the wear resistance of the polymer. The implications of the present results, taken together with the aforementioned literature results, are fully discussed vis-a-vis the use of crosslinked UHMWPE for fabricating articular components for arthroplasties.

  1. High temperature homogenization improves impact toughness of vitamin E-diffused, irradiated UHMWPE.

    PubMed

    Oral, Ebru; O'Brien, Caitlin; Doshi, Brinda; Muratoglu, Orhun K

    2017-06-01

    Diffusion of vitamin E into radiation cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used to increase stability against oxidation of total joint implant components. The dispersion of vitamin E throughout implant preforms has been optimized by a two-step process of doping and homogenization. Both of these steps are performed below the peak melting point of the cross-linked polymer (<140°C) to avoid loss of crystallinity and strength. Recently, it was discovered that the exposure of UHMWPE to elevated temperatures, around 300°C, for a limited amount of time in nitrogen, could improve the toughness without sacrificing wear resistance. We hypothesized that high temperature homogenization of antioxidant-doped, radiation cross-linked UHMWPE could improve its toughness. We found that homogenization at 300°C for 8 h resulted in an increase in the impact toughness (74 kJ/m 2 compared to 67 kJ/m 2 ), the ultimate tensile strength (50 MPa compared to 43 MPa) and elongation at break (271% compared to 236%). The high temperature treatment did not compromise the wear resistance or the oxidative stability as measured by oxidation induction time. In addition, the desired homogeneity was achieved at a much shorter duration (8 h compared to >240 h) by using high temperature homogenization. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1343-1347, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    PubMed

    Abdelgaied, A; Fisher, J; Jennings, L M

    2018-02-01

    A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson's ratio) and wear parameters of the moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily

  3. Predictors of degenerative medial meniscus extrusion: radial component and knee osteoarthritis.

    PubMed

    Lee, Dae-Hee; Lee, Bum-Sik; Kim, Jong-Min; Yang, Kyung-Sook; Cha, Eun-Jong; Park, Ji-Hun; Bin, Seong-Il

    2011-02-01

    the purpose of this study was to determine the effect of a radial tear on degenerative medial meniscus posterior horn tear extrusion and to identify predictors of medial meniscus extrusion. we reviewed the records of 102 knees with medial meniscus posterior horn tears and degeneration that underwent a partial meniscectomy. Tears were classified as root (n = 17) and non-root (n = 85) tears, or as radial (n = 46) and non-radial (n = 56) tears. Groups were compared in terms of absolute and relative meniscal extrusion, and the proportion of knees with major (> 3 mm) extrusion. Multiple regression analysis was used to identify predictors of extrusion. the radial group had greater mean absolute (4 ± 1 vs. 3 ± 1 mm, P = 0.001) and relative (31 ± 11 vs. 23 ± 12%, P = 0.031) extrusion than the non-radial group. The radial group also had a greater proportion of major extrusions than the non-radial group (74% vs. 26%; P = 0.016). In contrast, the root tear and non-root tear groups were similar in terms of mean absolute (3 ± 1 vs. 3 ± 1 mm, P = n.s.) and relative (30 ± 7 vs. 26 ± 13%; P = n.s.) extrusion and in terms of proportion with major extrusions (59 vs. 55%; P = n.s.). Extrusion was found to be associated with a similar strength with both the presence of a radial component and the preoperative Kellgren-Lawrence grade. meniscal extrusion was greater and more severe in knees with a radial tear component than in knees without a radial component. The incidence and degree of major extrusion was similar in knees with root tears and non-root tears. A radial component and knee osteoarthritis severity were similarly predictive of absolute and relative extrusion. Meniscal extrusion in osteoarthritic knees was associated not only with degenerative meniscal tear but also with osteoarthritis severity. Therefore, arthroscopic meniscal procedures, especially meniscal repair, should be cautiously considered in patients with meniscal extrusion.

  4. Femoral Component External Rotation Affects Knee Biomechanics: A Computational Model of Posterior-stabilized TKA.

    PubMed

    Kia, Mohammad; Wright, Timothy M; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Sculco, Peter K; Westrich, Geoffrey H; Imhauser, Carl W

    2018-01-01

    The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees? We incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and

  5. Application of Viscoelastic Fracture Model and Non-uniform Crack Initiation at Clinically Relevant Notches in Crosslinked UHMWPE

    PubMed Central

    Sirimamilla, P. Abhiram; Furmanski, Jevan; Rimnac, Clare M.

    2012-01-01

    The mechanism of crack initiation from a clinically relevant notch is not well-understood for crosslinked ultra high molecular weight polyethylene (UHMWPE) used in total joint replacement components. Static mode driving forces, rather than the cyclic mode conditions typically associated with fatigue processes, have been shown to drive crack propagation in this material. Thus, in this study, crack initiation in a notched specimen under a static load was investigated. A video microscope was used to monitor the notch surface of the specimen and crack initiation time was measured from the video by identifying the onset of crack initiation at the notch. Crack initiation was considered using a viscoelastic fracture theory. It was found that the mechanism of crack initiation involved both single layer and a distributed multi-layer phenomenon and that multi-layer crack initiation delayed the crack initiation time for all loading conditions examined. The findings of this study support that the viscoelastic fracture theory governs fracture mechanics in crosslinked UHMWPE. The findings also support that crack initiation from a notch in UHMWPE is a more complex phenomenon than treated by traditional fracture theories for polymers. PMID:23127638

  6. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    PubMed

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component. The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years).The primary indication was 14 times osteoarthritis and 5 times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years). Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants. At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The differences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant. Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee

  7. Comparison of mechanical and tribotechnical properties of UHMWPE reinforced with basalt fibers and particles

    NASA Astrophysics Data System (ADS)

    Panin, S. V.; Kornienko, L. A.; Alexenko, V. O.; Qitao, Huang; Ivanova, L. R.

    2016-11-01

    Mechanical and tribotechnical properties of UHMWPE composites reinforced with basalt fibers and particles under dry sliding friction and abrasion were investigated. It is shown that adding of the basalt particles provides higher wear resistance under the dry sliding friction while at abrasion filling by the basalt fibers is more efficient since the wear resistance of the reinforced UHMWPE composites is by 3.7 times higher in contrast with the neat polymer. Wear mechanisms of the polymeric UHMWPE composites under various types of wear are discussed.

  8. Evaluation of anterior knee pain in a PS total knee arthroplasty: the role of patella-friendly femoral component and patellar size.

    PubMed

    Atzori, F; Sabatini, L; Deledda, D; Schirò, M; Lo Baido, R; Baido, R L; Massè, A

    2015-04-01

    Total knee arthroplasty gives excellent objective results. Nevertheless, the subjective findings do not match the normal knee perception: Often, it depends on patellar pain onset. In this study, we analyzed clinical and radiological items that can affect resurfaced patellar tracking, and role of a patella-friendly femoral component and patellar size on patellar pain onset. Thirty consecutive patients were implanted using the same-cemented posterior-stabilized TKA associated with patella resurfacing. Fifteen patients were implanted using a classical femoral component, while another 15 patients were implanted using a patella-friendly femoral component. The statistical analysis was set to detect a significant difference (p < 0.05) in clinical and radiological outcomes related to several surgical parameters. Clinical and functional outcomes were recorded using the Knee Society Scoring System (KSS) and patellar pain with the Burnett questionnaire. Mean follow-up was 25 months. KSS results were excellent in both groups. Group 2 (patella-friendly femoral model) reached a higher percentage of 100 points in the clinical and functional KSS, but there was no statistical difference. Also, no statistical differences for Burnett Questionnaire results were recorded. We had one case of patellar clunk syndrome in the standard femoral component group and one poor result in the second group. Postoperative radiographic measurements evidenced no statistical differences in both groups. In group 1 (classical femoral component), better significant result (p < 0.05) war recorded at clinical evaluation according to the Knee Society Scoring System (KSS) in case of wider patellar component resurfaced. The present study reveals no statistically significant difference in the incidence of anterior knee pain between classical and "patella-friendly" femoral components. With the particular type of implant design utilized in this study, when the classical femoral component is used, bigger

  9. The Mechanical Properties and Modeling of Creep Behavior of UHMWPE/Nano-HA Composites

    NASA Astrophysics Data System (ADS)

    Li, Fan; Gao, Lilan; Gao, Hong; Cui, Yun

    2017-09-01

    Composites with different levels of hydroxyapatite (HA) content and ultra-high molecular weight polyethylene (UHMWPE) were prepared in this work. Mechanical properties of the composites were examined here, and to evaluate the effect of HA particles on the time-dependent behavior of the pure matrix, the creep and recovery performance of composites at various stress levels were also researched. As expected, the addition of HA influenced the time-dependent response of the UHMWPE and the effect had a strong dependence on the HA content. The creep and recovery strain of the composites significantly decreased with increasing HA content, and tensile properties were also impaired, which was due to the concentration of HA fillers. The mechanism and effect of HA dispersed into the UHMWPE matrix were examined by scanning electron microscopy. Additionally, since variations in the adjusted parameters revealed the impact of HA on the creep behavior of the UHMWPE matrix, Findley's model was employed. The results indicated that the analytical model was accurate for the prediction of creep of the pure matrix and its composites.

  10. Analysis of severely fractured glenoid components: clinical consequences of biomechanics, design, and materials selection on implant performance.

    PubMed

    Ansari, Farzana; Lee, Taylor; Malito, Louis; Martin, Audrey; Gunther, Stephen B; Harmsen, Samuel; Norris, Tom R; Ries, Mike; Van Citters, Douglas; Pruitt, Lisa

    2016-07-01

    The longevity of total shoulder replacement is primarily limited by the performance of the ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid component in vivo. Variations in glenoid design (conformity, thickness), biomechanics (joint kinematics), and UHMWPE material selection (sterilization, cross-linking) distinguish total shoulder replacements from hip and knee arthroplasty devices. These variables can lead to severe mechanical failures, including gross fracture. Sixteen retrieved glenoids with severe fracture were analyzed. The explant cohort included 3 material groups (gamma-sterilized Hylamer; gamma-sterilized UHMWPE; and gas plasma-sterilized, remelted, highly cross-linked UHMWPE [HXL]) and a range of conformities (0- to 10-mm radial mismatch). Analysis included fractography (optical and scanning electron microscopy) and Fourier transform infrared spectroscopy for oxidative analysis. Fracture primarily occurred along the exterior rim for all 16 explants. Fourier transform infrared analysis and fractography revealed significant oxidative embrittlement for all gamma-sterilized glenoids. Fatigue striations and internal flaws were evident on the fracture surface of the HXL glenoid, with little oxidation detected. Fracture initiated at the external rim of all devices. Elevated oxidation levels and visible material distortion for representative gamma-sterilized conventional and Hylamer devices suggest oxidative embrittlement as a driving force for crack inception and subsequent fracture. Brittle fracture of theHXL glenoid resulted from a combination of elevated contact stress due to a nonconforming surface, an internal flaw, and reduced resistance to fatigue crack growth. This demonstrates that glenoid fracture associated with oxidation has not been eliminated with the advent of modern materials (HXL) in the shoulder domain. Basic Science Study; Implant Retrieval Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by

  11. The effect of alpha-tocopherol on the oxidation and free radical decay in irradiated UHMWPE.

    PubMed

    Oral, Ebru; Rowell, Shannon L; Muratoglu, Orhun K

    2006-11-01

    We developed a radiation cross-linked ultra-high molecular weight polyethylene (UHMWPE) stabilized with alpha-tocopherol (Vitamin E) as a bearing material in total joint replacements. The stabilizing effect of alpha-tocopherol on free radical reactions in UHMWPE is not well understood. We investigated the effect of alpha-tocopherol on the oxidation and transformation of residual free radicals during real-time aging of alpha-tocopherol-doped, irradiated UHMWPE (alphaTPE) and irradiated UHMWPE (control). Samples were aged at 22 degrees C (room temperature) in air, at 40 degrees C in air and at 40 degrees C in water for 7 months. During the first month, alphaTPE showed some oxidation at the surface, which stayed constant thereafter. Control exhibited substantial oxidation in the subsurface region, which increased with time. The alkyl/allyl free radicals transformed to oxygen centered ones in both materials; this transformation occurred faster in alpha-TPE. In summary, the real-time oxidation behavior of alpha-TPE was consistent with that observed using accelerated aging methods. This new UHMWPE is oxidation resistant and is expected to maintain its properties in the long term.

  12. Micromechanical models for the stiffness and strength of UHMWPE macrofibrils

    NASA Astrophysics Data System (ADS)

    Dong, Hai; Wang, Zheliang; O'Connor, Thomas C.; Azoug, Aurelie; Robbins, Mark O.; Nguyen, Thao D.

    2018-07-01

    Ultrahigh molecular weight polyethylene (UHMWPE) fibers have a complex hierarchical structure that at the micron-scale is composed of oriented chain crystals, lamellar crystals, and amorphous domains organized into macrofibrils. We developed a computational micromechanical modeling study of the effects of the morphological structure and constituent material properties on the deformation mechanisms, stiffness and strength of the UHMWPE macrofibrils. Specifically, we developed four representative volume elements, which differed in the arrangement and orientation of the lamellar crystals, to describe the various macrofibrillar microstructures observed in recent experiments. The stiffness and strength of the crystals were determined from molecular dynamic simulations of a pure PE crystal. A finite deformation crystal plasticity model was used to describe the crystals and an isotropic viscoplastic model was used for the amorphous phase. The results show that yielding in UHMWPE macrofibrils under axial tension is dominated by the slip in the oriented crystals, while yielding under transverse compression and shear is dominated by slips in both the oriented and lamellar crystals. The results also show that the axial modulus and strength are mainly determined by the volume fraction of the oriented crystals and are insensitive to the arrangements of the lamellar crystals when the modulus of the amorphous phase is significantly smaller than that of the crystals. In contrast, the arrangement and size of the lamellar crystals have a significant effect on the stiffness and strength under transverse compression and shear. These findings can provide a guide for new materials and processing design to improve the properties of UHMWPE fibers by controlling the macrofibrillar morphologies.

  13. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees.

    PubMed

    Huang, Chun-Hsiung; Ho, Fang-Yuan; Ma, Hon-Ming; Yang, Chan-Tsung; Liau, Jiann-Jong; Kao, Hung-Chan; Young, Tai-Horng; Cheng, Cheng-Kung

    2002-09-01

    Osteolysis induced by ultrahigh molecular weight polyethylene wear debris has been recognized as the major cause of long-term failure in total joint arthroplasties. In a previous study, the prevalence of intraoperatively identified osteolysis during primary revision surgery was much higher in mobile bearing knee replacements (47%) than in fixed bearing knee replacements (13%). We postulated that mobile bearing knee implants tend to produce smaller sized particles. In our current study, we compared the particle size and morphology of polyethylene wear debris between failed mobile bearing and fixed bearing knees. Tissue specimens from interfacial and lytic regions were extracted during revision surgery of 10 mobile bearing knees (all of the low contact stress (LCS) design) and 17 fixed bearing knees (10 of the porous-coated anatomic (PCA) and 7 of the Miller/Galante design). Polyethylene particles were isolated from the tissue specimens and examined using both scanning electron microscopy and light-scattering analyses. The LCS mobile bearing knees produced smaller particulate debris (mean equivalent spherical diameter: 0.58 microm in LCS, 1.17 microm in PCA and 5.23 microm in M/G) and more granular debris (mean value: 93% in LCS, 77% in PCA and 15% in M/G).

  14. Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation.

    PubMed

    Kurtz, S M; Dumbleton, J; Siskey, R S; Wang, A; Manley, M

    2009-08-01

    The effect of very low concentrations of Vitamin E on the stability and mechanical behavior of UHMWPE remains unknown. We tested the hypothesis that the oxidation resistance of Vitamin E-blended UHMWPE would be influenced by trace doses of antioxidant, resin, and radiation treatment. Trace concentrations (< or =500 ppm w/w%) of alpha-tocopherol (Vitamin E) were blended separately with GUR 1020 and 1050 resins and molded into disks. From each disk, three groups of 10 mm thick blocks were machined: (1) no irradiation (control); (2) 30 kGy of gamma irradiation in nitrogen; and (3) 75 kGy of gamma irradiation in air. Specimens were subjected to three aging protocols: (a) no aging (control); (b) two weeks and (c) four weeks of accelerated aging in accordance with ASTM F 2003 (i.e., 70 degrees C and 5 atm oxygen). The minimum concentration of Vitamin E needed to stabilize UHMWPE during our accelerated tests depended upon the method of radiation processing. For the 30 and 75 kGy irradiated materials, the addition of 125 ppm or more Vitamin E was sufficient to maintain baseline mechanical and chemical properties through two weeks of accelerated aging. For these groups, the addition of 375 ppm or 500 ppm, respectively, was necessary to maintain baseline mechanical and chemical properties throughout the four-week accelerated aging period. UHMWPE resin molecular weight did not have an effect on oxidation behavior. The results of this experiment therefore supported our hypotheses that trace concentrations of Vitamin E, coupled with radiation treatment-but not resin grade-influence the mechanical and oxidative degradation behavior of UHMWPE.

  15. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    PubMed

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  16. Radiopaque UHMWPE sublaminar cables for spinal deformity correction: Preclinical mechanical and radiopacifier leaching assessment.

    PubMed

    Roth, Alex K; Boon-Ceelen, Karlien; Smelt, Harold; van Rietbergen, Bert; Willems, Paul C; van Rhijn, Lodewijk W; Arts, Jacobus J

    2018-02-01

    Polymeric sublaminar cables have a number of advantages over metal cables in the field of spinal deformity surgery, with decreased risk of neurological injury and potential for higher correction forces as the two most predominant. However, currently available polymer cables are radiolucent, precluding postoperative radiological assessment of instrumentation stability and integrity. This study provides a preclinical assessment of a woven UHMWPE cable made with radiopaque UHMWPE fibers. Our primary goal was to determine if the addition of a radiopacifier negatively affects the mechanical properties of UHMWPE woven cables. Tensile mechanical properties were determined and compared to suitable controls. Radiopacity was evaluated and radiopacifier leaching was assessed in vitro and in vivo. Finally, in vivo bismuth organ content was quantified after a 24-week implantation period in sheep. Results show that the mechanical properties of woven UHMWPE cables were not deleteriously affected by the addition of homogenously dispersed bismuth oxide particles within each fiber. Limited amounts of bismuth oxide were released in vitro, well below the toxicological threshold. Tissue concentrations lower than generally accepted therapeutic dosages for use against gastrointestinal disorders, well below toxic levels, were discovered in vivo. These results substantiate controlled clinical introduction of these radiopaque UHMWPE cables. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 771-779, 2018. © 2017 Wiley Periodicals, Inc.

  17. Influence of Component Rotation in Total Knee Arthroplasty on Tibiofemoral Kinematics-A Cadaveric Investigation.

    PubMed

    Maderbacher, Guenther; Keshmiri, Armin; Springorum, Hans R; Maderbacher, Hermann; Grifka, Joachim; Baier, Clemens

    2017-09-01

    Physiological tibiofemoral kinematics have been shown to be important for good knee function after total knee arthroplasty (TKA). The purpose of the present study was to investigate the influence of component rotation on tibiofemoral kinematics during knee flexion. We asked which axial component alignment best reconstructs physiological tibiofemoral kinematics and which combinations should be avoided. Ten healthy cadaveric knees were examined. By means of a navigational device, tibiofemoral kinematics between 0° and 90° of flexion were assessed before and after TKA using the following different rotational component alignment: femoral components: ligament balanced, 6° internal, 3° external rotation, and 6° external rotation in relation to the posterior condylar line; tibial components: self-adapted, 6° internal rotation, and 6° external rotation. Physiological tibiofemoral kinematics could be partly reconstructed by TKA. Ligament-balanced femoral rotation and 6° femoral external rotation both in combination with 6° tibial component external rotation, and 3° femoral external rotation in combination with 6° tibial component internal rotation or self-aligning tibial component were able to restore tibial longitudinal rotation. Largest kinematical differences were found for the combination femoral component internal and tibial component external rotations. From a kinematic-based view, surgeons should avoid internal rotation of femoral components. However, even often recommended combinations of rotational component alignment (3° femoral external and tibial external rotation) significantly change tibiofemoral kinematics. Self-aligning tibial components solely restored tibiofemoral kinematics with the combination of 3° femoral component of external rotation. For the future, navigational devices might help to axially align components to restore patient-specific and natural tibiofemoral kinematics. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    PubMed

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  19. Physical properties and biocompatibility of UHMWPE-derived materials modified by synchrotron radiation.

    PubMed

    Bykova, Iu; Weinhardt, V; Kashkarova, A; Lebedev, S; Baumbach, T; Pichugin, V; Zaitsev, K; Khlusov, I

    2014-08-01

    The applications of synchrotron radiation (SR) in medical imaging have become of great use, particularly in angiography, bronchography, mammography, computed tomography, and X-ray microscopy. Thanks to recently developed phase contrast imaging techniques non-destructive preclinical testing of low absorbing materials such as polymers has become possible. The focus of the present work is characterization and examination of UHMWPE-derived materials widely used in medicine, before and after their exposure to SR during such testing. Physical properties, such as wettability, surface energy, IR-spectroscopy, roughness, optical microscopy, microhardness measurements of UHMWPE samples were studied before and after SR. The relationship between a growth of UHMWPE surface hydrophilicity after SR and surface colonization by stromal cells was studied in vitro. Obtained results demonstrate that SR may be used as prospective direction to examine bulk (porous) structure of polymer materials and/or to modify polymer surface and volume for tissue engineering.

  20. Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty

    PubMed Central

    2011-01-01

    Background and purpose The choice of either all-polyethylene (AP) tibial components or metal-backed (MB) tibial components in total knee arthroplasty (TKA) remains controversial. We therefore performed a meta-analysis and systematic review of randomized controlled trials that have evaluated MB and AP tibial components in primary TKA. Methods The search strategy included a computerized literature search (Medline, EMBASE, Scopus, and the Cochrane Central Register of Controlled Trials) and a manual search of major orthopedic journals. A meta-analysis and systematic review of randomized or quasi-randomized trials that compared the performance of tibial components in primary TKA was performed using a fixed or random effects model. We assessed the methodological quality of studies using Detsky quality scale. Results 9 randomized controlled trials (RCTs) published between 2000 and 2009 met the inclusion quality standards for the systematic review. The mean standardized Detsky score was 14 (SD 3). We found that the frequency of radiolucent lines in the MB group was significantly higher than that in the AP group. There were no statistically significant differences between the MB and AP tibial components regarding component positioning, knee score, knee range of motion, quality of life, and postoperative complications. Interpretation Based on evidence obtained from this study, the AP tibial component was comparable with or better than the MB tibial component in TKA. However, high-quality RCTs are required to validate the results. PMID:21895503

  1. Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients

    PubMed Central

    Jansson, V.; Giurea, A.

    2016-01-01

    Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear in in vitro and animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as well as UHMWPE wear debris. The authors hypothesized no difference between the used biomaterials. Methods and Materials. In 10 patients during knee revision surgery of a rotating-hinge-knee-implant-design, synovial tissue samples were achieved (tibial inserts: UHMWPE; bushings and flanges: CFR-PEEK). One additional patient received revision surgery without any PEEK components as a control. The tissue was paraffin-embedded, sliced into 2 μm thick sections, and stained with hematoxylin and eosin in a standard process. A modified panoptical staining was also done. Results. A “wear-type” reaction was seen in the testing and the control group. In all samples, the UHMWPE particles were scattered in the tissue or incorporated in giant cells. CFR-PEEK particles were seen as conglomerates and only could be found next to vessels. CFR-PEEK particles showed no giant-cell reactions. In conclusion, the hypothesis has to be rejected. UHMWPE and PEEK showed a different scatter-behavior in human synovial tissue. PMID:27766256

  2. A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses.

    PubMed

    McGloughlin, T M; Murphy, D M; Kavanagh, A G

    2004-01-01

    Degradation of tibial inserts in vivo has been found to be multifactorial in nature, resulting in a complex interaction of many variables. A range of kinematic conditions occurs at the tibio-femoral interface, giving rise to various degrees of rolling and sliding at this interface. The movement of the tibio-femoral contact point may be an influential factor in the overall wear of ultra-high molecular weight polyethylene (UHMWPE) tibial components. As part of this study a three-station wear-test machine was designed and built to investigate the influence of rolling and sliding on the wear behaviour of specific design aspects of contemporary knee prostheses. Using the machine, it is possible to monitor the effect of various slide roll ratios on the performance of contemporary bearing designs from a geometrical and materials perspective.

  3. Correcting Severe Varus Deformity Using Trial Components During Total Knee Arthroplasty.

    PubMed

    Kim, Man S; Koh, In J; Choi, Young J; Kim, Yong D; In, Yong

    2017-05-01

    Extensive medial soft tissue release may be necessary to correct severe varus deformity during total knee arthroplasty (TKA). However, this procedure may result in instability. Here, we describe a novel soft tissue balancing technique, which can minimize medial release in severe varus deformity during TKA. Fifty knees (40 patients) with hip-knee-ankle angle of more than 20° of varus were corrected using this technique (group 1). After achieving flexion gap balancing by needle puncturing and spreading of the superficial medial collateral ligament, extension gap balancing was obtained by gradual extension with the trial components in place. After group 1 was set, a one-to-one patient-matched control group who had mild varus deformity was selected by propensity score matching (50 knees, 48 patients, group 2). At postoperative 1 year, mediolateral laxity was compared between the 2 groups using the stress radiographs. Clinical outcomes were also compared using the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index score. There were no differences in mean medial and lateral laxities between groups 1 and 2 at 1 year after the operation (medial laxity: 2.3° ± 1.4° and 2.7° ± 1.3°, respectively, P = .310) (lateral laxity: 3.6° ± 1.7° and 3.2° ± 2.0°, respectively, P = .459). There were no significant differences in postoperative clinical scores and knee alignment. Our technique of obtaining extension gap balancing using trial components led to safe and effective balancing by avoiding unnecessary extensive release in severe varus deformity during TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. EFFECTS OF TRITIUM EXPOSURE ON UHMW-PE, PTFE, AND VESPEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, E; Kirk Shanahan, K

    2006-05-31

    Samples of three polymers, Ultra-High Molecular Weight Polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE, also known as Teflon{reg_sign}), and Vespel{reg_sign} polyimide were exposed to 1 atmosphere of tritium gas at ambient temperature for varying times up to 2.3 years in closed containers. Sample mass and size measurements (to calculate density), spectra-colorimetry, dynamic mechanical analysis (DMA), and Fourier-transform infrared spectroscopy (FT-IR) were employed to characterize the effects of tritium exposure on these samples. Changes of the tritium exposure gas itself were characterized at the end of exposure by measuring total pressure and by mass spectroscopic analysis of the gas composition. None of the polymersmore » exhibited significant changes of density. The color of initially white UHMW-PE and PTFE dramatically darkened to the eye and the color also significantly changed as measured by colorimetry. The bulk of UHMW-PE darkened just like the external surfaces, however the fracture surface of PTFE appeared white compared to the PTFE external surfaces. The white interior could have been formed while the sample was breaking or could reflect the extra tritium dose at the surface directly from the gas. The dynamic mechanical response of UHMW-PE was typical of radiation effects on polymers- an initial stiffening (increased storage modulus) and reduction of viscous behavior after three months exposure, followed by lowering of the storage modulus after one year exposure and longer. The storage modulus of PTFE increased through about nine months tritium exposure, then the samples became too weak to handle or test using DMA. Characterization of Vespel{reg_sign} using DMA was problematic--sample-to-sample variations were significant and no systematic change with tritium exposure could be discerned. Isotopic exchange and incorporation of tritium into UHMW-PE (exchanging for protium) and into PTFE (exchanging for fluorine) was observed by FT-IR using an

  5. Wear Measurement of Highly Cross-Linked UHMWPE Using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus; Laurent, Michael P.; Dwivedi, Yash

    2013-01-29

    The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei upmore » to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  6. Biocompatibility evaluation of HDPE-UHMWPE reinforced β-TCP nanocomposites using highly purified human osteoblast cells.

    PubMed

    Shokrgozar, M A; Farokhi, M; Rajaei, F; Bagheri, M H A; Azari, Sh; Ghasemi, I; Mottaghitalab, F; Azadmanesh, K; Radfar, J

    2010-12-15

    Biocompatibility of β-TCP/HDPE-UHMWPE nanocomposite as a new bone substitute material was evaluated by using highly purified human osteoblast cells. Human osteoblast cells were isolated from bone tissue and characterized by immunofluorescence Staining before and after purification using magnetic bead system. Moreover, proliferation, alkaline phosphatase production, cell attachment, calcium deposition, gene expression, and morphology of osteoblast cells on β-TCP/HDPE-UHMWPE nanocomposites were evaluated. The results have shown that the human osteoblast cells were successfully purified and were suitable for subsequent cell culturing process. The high proliferation rate of osteoblast cells on β-TCP/HDPE-UHMWPE nanocomposite confirmed the great biocompatibility of the scaffold. Expression of bone-specific genes was taken place after the cells were incubated in composite extract solutions. Furthermore, osteoblast cells were able to mineralize the matrix next to composite samples. Scanning electron microscopy demonstrated that cells had normal morphology on the scaffold. Thus, these results indicated that the nanosized β-TCP/HDPE-UHMWPE blend composites could be potential scaffold, which is used in bone tissue engineering. Copyright © 2010 Wiley Periodicals, Inc.

  7. Effects of physiotherapy treatment on knee osteoarthritis gait data using principal component analysis.

    PubMed

    Gaudreault, Nathaly; Mezghani, Neila; Turcot, Katia; Hagemeister, Nicola; Boivin, Karine; de Guise, Jacques A

    2011-03-01

    Interpreting gait data is challenging due to intersubject variability observed in the gait pattern of both normal and pathological populations. The objective of this study was to investigate the impact of using principal component analysis for grouping knee osteoarthritis (OA) patients' gait data in more homogeneous groups when studying the effect of a physiotherapy treatment. Three-dimensional (3D) knee kinematic and kinetic data were recorded during the gait of 29 participants diagnosed with knee OA before and after they received 12 weeks of physiotherapy treatment. Principal component analysis was applied to extract groups of knee flexion/extension, adduction/abduction and internal/external rotation angle and moment data. The treatment's effect on parameters of interest was assessed using paired t-tests performed before and after grouping the knee kinematic data. Increased quadriceps and hamstring strength was observed following treatment (P<0.05). Except for the knee flexion/extension angle, two different groups (G(1) and G(2)) were extracted from the angle and moment data. When pre- and post-treatment analyses were performed considering the groups, participants exhibiting a G(2) knee moment pattern demonstrated a greater first peak flexion moment, lower adduction moment impulse and smaller rotation angle range post-treatment (P<0.05). When pre- and post-treatment comparisons were performed without grouping, the data showed no treatment effect. The results of the present study suggest that the effect of physiotherapy on gait mechanics of knee osteoarthritis patients may be masked or underestimated if kinematic data are not separated into more homogeneous groups when performing pre- and post-treatment comparisons. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Prediction of Knee Joint Contact Forces From External Measures Using Principal Component Prediction and Reconstruction.

    PubMed

    Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J

    2018-05-29

    Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.

  9. UHMWPE Sublaminar Wires in Posterior Spinal Instrumentation: Stability and Biocompatibility Assessment in an Ovine Pilot Study.

    PubMed

    Bogie, Rob; Voss, Laura; Arts, Jacobus J; Lataster, Arno; Willems, Paul C; Brans, Boudewijn; van Rhijn, Lodewijk W; Welting, Tim J M

    2016-12-01

    An animal study. To explore ultra-high molecular weight polyethylene (UHMWPE) sublaminar wires in spinal surgery and to assess stability and biocompatibility of the UHMWPE instrumentation in an ovine model. Sublaminar wiring is a well-established technique in segmental scoliosis surgery. However, during introduction and/or removal of the metal sublaminar wires, neurological problems can occur. Abrasion after cutting metal wires for removal can lead to damage to the dural sac. Sublaminar wires have to withhold large forces and breakage of the wires can occur. Different types of sublaminar wires have been developed to address these problems. UHMWPE sublaminar wires can potentially substitute currently used metal sublaminar metal wires. In vivo testing and biocompatibility analysis of UHMWPE wires are recommended before clinical use in spinal surgery. In 6 immature sheep, pedicle screws were instrumented at lumbar level L4 and attached with titanium rods to 4 thoracolumbar vertebrae using 3- and 5-mm-wide UHMWPE sublaminar wiring constructions in 5 animals. Titanium sublaminar wires were applied in 1 animal to function as a control subject. After a follow-up period of 16 weeks, the animals were sacrificed and the spines were isolated. Radiographs and computed tomography (CT) scans were made to assess stability of the instrumentation. The vertebrae were dissected for macroscopic and histologic evaluation. None of the wires had loosened and the instrumentation remained stable. CT scans and radiographs showed no signs of failure of the instrumentation and no neurological complications occurred. Although several bony bridges were seen on CT, growth was observed at the operated levels. Biocompatibility was assessed by macroscopical and histologic analysis, showing no signs of dural or epidural inflammation. This pilot animal study shows that UHMWPE sublaminar wiring is a safe technique. The UHMWPE wires are biocompatible and provide sufficient stability in spinal

  10. Effect of Boundary Conditions on the Back Face Deformations of Flat UHMWPE Panels

    DTIC Science & Technology

    2014-12-01

    Zhang [2] carried out a numerical study of the effects of clamping type and clamping pressure on the ballistic performance of woven Kevlar , and found...effects of composite size were also studied. Singletary [5] studied the effects of boundary conditions and panel sizes on V50 for Kevlar KM2 fabric. The...on the BFD in flat UHMWPE panels. UHMWPE possesses high tenacity and high strength compared to Kevlar , as a result of which it is the material of

  11. Highly crosslinked polyethylene: a safe alternative to conventional polyethylene for dual mobility cup mobile component. A biomechanical validation.

    PubMed

    Malatray, Matthieu; Roux, Jean-Paul; Gunst, Stanislas; Pibarot, Vincent; Wegrzyn, Julien

    2017-03-01

    Dual mobility cup (DMC) consists of a cobalt-chromium (CoCr) alloy cup articulated with a polyethylene (PE) mobile component capturing the femoral head in force using a snap-fit technique. This biomechanical study was the first to evaluate and compare the generation of cracks in the retentive area of DMC mobile components made of highly crosslinked PE (XLPE) or conventional ultra-high molecular weight PE (UHMWPE). Eighty mobile components designed for a 52-mm diameter Symbol® DMC (Dedienne Santé, Mauguio, France) and a 28-mm diameter femoral head were analyzed. Four groups of 20 mobile components were constituted according to the PE material: raw UHMWPE, sterilized UHMWPE, annealed XLPE and remelted XLPE. Ten mobile components in each group were impacted with a 28-mm diameter CoCr femoral head using a snap-fit technique. The occurrence, location and area of the cracks in the retentive area were investigated using micro-CT (Skyscan 1176®, Bruker, Aarsellar, Belgium) with a 35 μm nominal isotropic voxel size by two observers blinded to the PE material and impaction or not of the mobile components. Compared to conventional UHMWPE, the femoral head snap-fit did not generate more or wider cracks in the retentive area of annealed or remelted XLPE mobile components. This biomechanical study suggests that XLPE in DMC could be a safe alternative to conventional UHMWPE regarding the generation of cracks in the retentive area related to the femoral head snap-fit.

  12. Wear Measurement of Highly Cross-linked UHMWPE using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus A.; Laurent, Michael P.; Dwivedi, Yasha

    2013-01-01

    The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenousmore » distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  13. Radiation synthesis of a new amidoximated UHMWPE fibrous adsorbent with high adsorption selectivity for uranium over vanadium in simulated seawater

    NASA Astrophysics Data System (ADS)

    Gao, Qianhong; Hu, Jiangtao; Li, Rong; Xing, Zhe; Xu, Lu; Wang, Mouhua; Guo, Xiaojing; Wu, Guozhong

    2016-05-01

    A new kind of highly efficient adsorbent material has been fabricated in this study for the purpose of extracting uranium from seawater. Ultra-high molecular weight polyethylene (UHMWPE) fiber was used as a trunk material for the adsorbent, which was prepared by a series of modification reactions, as follows: (1) grafting of glycidyl methacrylate (GMA) and methyl acrylate (MA) onto UHMWPE fibers via 60Co γ-ray pre-irradiation; (2) aminolyzation of UHMWPE fiber by the ring-opening reaction between of epoxy groups PGMA and ethylene diamine (EDA); (3) Michael addition of amino groups with acrylonitrile (AN) to yield nitrile groups; (4) amidoximation of the attached nitrile moieties by hydroxylamine in dimethyl sulfoxide-water mixture. Modified UHMWPE fibers were characterized by means of attenuated total reflectance-Fourier transformed infrared spectroscopy (ATR-FTIR), thermogravimetric analysis (TGA) and scanning electron microscopy (SEM) to confirm the attachment of amidoxime (AO) groups onto the UHMWPE fibers. The results of X-ray diffraction (XRD) and single fiber tensile strength verified that the modified UHMWPE fiber retained excellent mechanical properties at a low absorbed radiation dose. The adsorption performance of the UHMWPE fibrous adsorbent was evaluated by subjecting it to an adsorption test in simulated seawater using a continuous-flow mode. The amount of uranium adsorbed by this AO-based UHMWPE fibrous adsorbent was 1.97 mg-U/g after 42 days. This new adsorbent also showed high selectivity for the uranyl ion, and its selectivity for metal ions was found to decrease in the following order: U>Cu>Fe>Ca>Mg>Ni>Zn>Pb>V>Co. The adsorption selectivity for uranium is significantly higher than that for vanadium. In addition, preparation of this modified adsorbent consumes much smaller amounts of the toxic acrylonitrile monomer than the conventional preparation methods of AO-based polyethylene fibers.

  14. Total knee arthroplasty with an oxidised zirconium femoral component: ten-year survivorship analysis.

    PubMed

    Ahmed, I; Salmon, L J; Waller, A; Watanabe, H; Roe, J P; Pinczewski, L A

    2016-01-01

    Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome. A total of 303 consecutive TKAs were performed in 278 patients with a mean age of 68 years (45 to 89). The rate of survival ten years post-operatively as assessed using Kaplan-Meier analysis was 97% (95% confidence interval 94 to 99) with revision for any reason as the endpoint. There were no revisions for loosening, osteolysis or failure of the implant. There was a significant improvement in all components of the WOMAC score at final follow-up (p < 0.001). The mean individual components of the KOOS score for symptoms (82.4 points; 36 to 100), pain (87.5 points; 6 to 100), activities of daily life (84.9 points; 15 to 100) and quality of life (71.4 points; 6 to 100) were all at higher end of the scale. This study provides further supportive evidence that the oxidised zirconium TKA gives comparable rates of survival with other implants and excellent functional outcomes ten years post-operatively. Total knee arthroplasty with an oxidised zirconium femoral component gives comparable long-term rates of survival and functional outcomes with conventional implants. ©2016 The British Editorial Society of Bone & Joint Surgery.

  15. Using Patient Demographics and Statistical Modeling to Predict Knee Tibia Component Sizing in Total Knee Arthroplasty.

    PubMed

    Ren, Anna N; Neher, Robert E; Bell, Tyler; Grimm, James

    2018-06-01

    Preoperative planning is important to achieve successful implantation in primary total knee arthroplasty (TKA). However, traditional TKA templating techniques are not accurate enough to predict the component size to a very close range. With the goal of developing a general predictive statistical model using patient demographic information, ordinal logistic regression was applied to build a proportional odds model to predict the tibia component size. The study retrospectively collected the data of 1992 primary Persona Knee System TKA procedures. Of them, 199 procedures were randomly selected as testing data and the rest of the data were randomly partitioned between model training data and model evaluation data with a ratio of 7:3. Different models were trained and evaluated on the training and validation data sets after data exploration. The final model had patient gender, age, weight, and height as independent variables and predicted the tibia size within 1 size difference 96% of the time on the validation data, 94% of the time on the testing data, and 92% on a prospective cadaver data set. The study results indicated the statistical model built by ordinal logistic regression can increase the accuracy of tibia sizing information for Persona Knee preoperative templating. This research shows statistical modeling may be used with radiographs to dramatically enhance the templating accuracy, efficiency, and quality. In general, this methodology can be applied to other TKA products when the data are applicable. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study.

    PubMed

    Barbadoro, P; Ensini, A; Leardini, A; d'Amato, M; Feliciangeli, A; Timoncini, A; Amadei, F; Belvedere, C; Giannini, S

    2014-12-01

    Unicompartmental knee arthroplasty (UKA) has shown a higher rate of revision compared with total knee arthroplasty. The success of UKA depends on prosthesis component alignment, fixation and soft tissue integrity. The tibial cut is the crucial surgical step. The hypothesis of the present study is that tibial component malalignment is correlated with its risk of loosening in UKA. This study was performed in twenty-three patients undergoing primary cemented unicompartmental knee arthroplasties. Translations and rotations of the tibial component and the maximum total point motion (MTPM) were measured using radiostereometric analysis at 3, 6, 12 and 24 months. Standard radiological evaluations were also performed immediately before and after surgery. Varus/valgus and posterior slope of the tibial component and tibial-femoral axes were correlated with radiostereometric micro-motion. A survival analysis was also performed at an average of 5.9 years by contacting patients by phone. Varus alignment of the tibial component was significantly correlated with MTPM, anterior tibial sinking, varus rotation and anterior and medial translations from radiostereometry. The posterior slope of the tibial component was correlated with external rotation. The survival rate at an average of 5.9 years was 89%. The two patients who underwent revision presented a tibial component varus angle of 10° for both. There is correlation between varus orientation of the tibial component and MTPM from radiostereometry in unicompartmental knee arthroplasties. Particularly, a misalignment in varus larger than 5° could lead to risk of loosening the tibial component. Prognostic studies-retrospective study, Level II.

  17. Does lateral versus medial exposure influence total knee tibial component final external rotation? A CT based study.

    PubMed

    Passeron, D; Gaudot, F; Boisrenoult, P; Fallet, L; Beaufils, P

    2009-10-01

    A previous study demonstrated that performing a total knee arthroplasty through a lateral approach including anterior tibial tuberosity (ATT) osteotomy (refixed in its original position) presented numerous advantages: correcting the preoperative patella lateral tilt and improving postoperative patella tracking. We hypothesized that these improvements in patella centering were, at least in part, due to an increased external rotation of the tibial component. Postoperative scannographic studies were, therefore, undertaken to measure tibial component rotation and analyze the results according the medial and lateral exposure used. Rotational positioning of the tibial component is influenced by the lateral or medial approach selected at surgery. Forty-five CAT scans, performed according to the protocol criteria of the French Hip and Knee Society (SFHG), were studied 3 months postoperatively: 15 knees operated through the lateral approach and 30 knees operated through a standard medial approach. The total knee utilized in all these cases was a posteriorly stabilized, fixed-bearing, design. We measured first the angle formed between the perpendicular to the transverse axis of the tibial component and the axis joining the ATT to the center of the knee; second we also measured the coronal distance between the center of the component and the anterior tibial tuberosity (ATT). In the group using the medial approach, the lateral position of the ATT was 7 + or - 3mm with a rotation angle of 18 degrees . In the group using the lateral approach these measurements were respectively 1 + or - 4mm and 2 degrees (p<0.0001). External rotation of the tibial component is substantially increased by the lateral approach compared to the medial approach. Better exposure of the lateral tibial plateau is probably responsible of this difference. This increased external rotation improves postoperative patella tracking. Prospective; comparative; non-randomized study; level 3. 2009 Elsevier Masson

  18. Evaluating the suitability of highly cross-linked and remelted materials for use in posterior stabilized knees.

    PubMed

    Huot, J Caitlin; Van Citters, Douglas W; Currier, John H; Currier, Barbara H; Mayor, Michael B; Collier, John P

    2010-11-01

    Posterior stabilized (PS) knee designs are a popular choice for cruciate sacrificing knee arthroplasty procedures. The introduction of PS inserts fabricated from highly cross-linked and remelted Ultra High Molecular Weight Polyethylene (UHMWPE) has recently generated concern as these materials have been shown to possess reduced mechanical properties. This study investigated whether highly cross-linked and remelted UHMWPE material (referred to as XRP) can be expected to perform similarly to historical gamma-air polyethylene, which has suffered few reported incidences of tibial post failure. Never-implanted gamma-air PS tibial inserts shelf-aged 14 years were examined and compared to XRP materials. Evaluation of oxidation levels, impact toughness, and fatigue strength demonstrated never-implanted gamma-air PS tibial inserts to possess nonuniform mechanical properties. Despite severe oxidation along the exterior of gamma-air tibial posts, comparatively low oxidation levels at the center of the tibial posts corresponded to sufficiently high mechanical properties. XRP material (75 kGy) showed superior impact toughness over shelf aged gamma-air material; however, tibial post fatigue testing demonstrated XRP material (100 kGy) to be less resistant to fatigue failure than historical gamma-air material. Results from this study indicate that XRP materials (100 kGy) may demonstrate an inferior resistance to tibial post failure than historical polyethylene. © 2010 Wiley Periodicals, Inc.

  19. A novel alginate-encapsulated system to study biological response to critical-sized wear particles of UHMWPE loaded with alendronate sodium.

    PubMed

    Liu, Yumei; Shi, Feng; Bo, Lin; Zhi, Wei; Weng, Jie; Qu, Shuxin

    2017-10-01

    The aim of this study was to develop a novel alginate-encapsulated system (Alg beads) to investigate the cell response to critical-sized wear particles of ultra-high molecular weight polyethylene loaded with alendronate sodium (UHMWPE-ALN), one of the most effective drugs to treat bone resorption in clinic. The extrusion method was used to prepare Alg beads encapsulating rat calvarial osteoblasts (RCOs) and critical-sized UHMWPE-ALN wear particles with spherical morphology and uniform size. The morphology, permeability and stability of Alg beads were characterized. The proliferation, ALP activity, cell apoptosis and distribution of live/dead RCOs co-cultured with wear particles in Alg beads were evaluated. RCOs and critical-sized UHMWPE-ALN wear particles distributed evenly and contacted efficiently in Alg beads. Alg beads were both permeable to trypsin and BSA, while the smaller the molecular was, the larger the diffuse was. The proliferation of RCOs in Alg beads increased with time, which indicated that Alg beads provided suitable conditions for cell culture. The long-term stability of Alg beads indicated the possibility for the longer time of co-cultured cells with wear particles. Critical-sized UHMWPE-ALN and UHMWPE wear particles both inhibited the proliferation and differentiation of RCOs, and induced the apoptosis of RCOs encapsulated in Alg beads. However, these effects could be significantly alleviated by the ALN released from the critical-sized UHMWPE-ALN wear particles. The present results suggested that this novel-developed co-culture system was feasible to evaluate the cell response to critical-sized UHMWPE-ALN wear particles for a longer time. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Outcome of prosthesis matched and unmatched patella components in primary and revision total knee replacement.

    PubMed

    Lewis, Peter L; Gamboa, Ai E; Campbell, David G; Lorimer, Michelle

    2017-10-01

    Although knee replacements have specifically designed patella prostheses that correspond to the geometry of their femoral components, a patella prosthesis that is unmatched to the femoral component may occasionally be inserted. In revision total knee arthroplasty (TKA), an originally resurfaced patella may be left, but the femoral component revised to one that does not match the patella. Few studies have compared the outcome of matched and unmatched patella components in TKA. This study compared the primary or revision TKA outcome of procedures where patella components matched to their femoral counterparts were inserted, with procedures using patella and femoral components that were unmatched. Data on all primary and revision TKA procedures without a patella component or a matched or an unmatched patella component were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Revision surgery was the outcome measure. Cumulative percent revised (CPR) were calculated and Hazard ratios with p values were used to test statistical significance. In primary TKA, there were higher rates of revision where unmatched patella components were used, regardless of implant design. There was no difference in the second revision rates of unmatched versus matched patella component groups. This was evident where delayed resurfacing was carried out, and where the patella prosthesis was left alone but the femoral component was changed. All primary TKA procedures require a patella component corresponding to the femoral component if the patella is resurfaced. Conversely, revision knee arthroplasties are not affected by the use of dissimilar patella and femoral components. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.

    PubMed

    Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi

    2016-09-01

    Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for

  2. Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene.

    PubMed

    Connelly, G M; Rimnac, C M; Wright, T M; Hertzberg, R W; Manson, J A

    1984-01-01

    The relative fatigue crack propagation resistance of plain and carbon fiber-reinforced ultrahigh molecular weight polyethylene (UHMWPE) was determined from cyclic loading tests performed on compact tension specimens machined from the tibial components of total knee prostheses. Both materials were characterized by dynamic mechanical spectroscopy, X-ray diffraction, and differential scanning calorimetry. The cyclic tests used loading in laboratory air at 5 Hz using a sinusoidal wave form. Dynamic mechanical spectroscopy showed that the reinforced UHMWPE had a higher elastic storage modulus than the plain UHMWPE, whereas X-ray diffraction and differential scanning calorimetry showed that the percent crystallinity and degree of order in the crystalline regions were similar for the two materials. Fatigue crack propagation in both materials proved to be very sensitive to small changes in the applied cyclic stress intensity range. A 10% increase in stress intensity resulted in approximately an order of magnitude increase in fatigue crack growth rate. The fatigue crack propagation resistance of the reinforced UHMWPE was found to be significantly worse than that of the plain UHMWPE. This result was attributed to poor bonding between the carbon fibers and the UHMWPE matrix and the ductile nature of the matrix itself.

  3. The elimination of free radicals in irradiated UHMWPEs with and without vitamin E stabilization by annealing under pressure.

    PubMed

    Oral, Ebru; Ghali, Bassem W; Muratoglu, Orhun K

    2011-04-01

    Radiation crosslinking of ultrahigh molecular weight polyethylene (UHMWPE) has been used to decrease the wear of joint implant bearing surfaces. While radiation crosslinking has been successful in decreasing femoral head penetration into UHMWPE acetabular liners in vivo, postirradiation thermal treatment of the polymer is required to ensure the oxidative stability of joint implants in the long term. Two types of thermal treatment have been used: (i) annealing below the melting point preserves the mechanical properties but the residual free radicals trapped in the crystalline regions are not completely eliminated, leading to oxidation in the long-term and (ii) annealing above the melting point (melting) eliminates the free radicals but leads to a decrease in mechanical properties through loss of crystallinity during the melting process. In this study, we hypothesized that free radicals could be reduced by annealing below the melting point under pressure effectively without melting due to the elevation of the melting point. By avoiding the complete melting of UHMWPE, mechanical properties would be preserved. Our hypothesis tested positive in that we found the radiation-induced free radicals to be markedly reduced (below the detection limit of state-of-the-art electron spin resonance) by thermal annealing under pressure in radiation crosslinked virgin UHMWPE and UHMWPE/vitamin-E blends without loss of mechanical properties. Copyright © 2011 Wiley Periodicals, Inc.

  4. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.

    PubMed

    Han, H S; Kang, S-B; Yoon, K S

    2007-11-01

    We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 45). We compared the radiologically-loose and revised knees with those which had remained well-fixed to identify the factors which had contributed to this high rate of aseptic loosening. Post-operatively, the mean maximum flexion was 136 degrees (110 degrees to 140 degrees) in the loosened group and 125 degrees (95 degrees to 140 degrees) in the well-fixed group (independent t-test, p = 0.022). Squatting, kneeling, or sitting cross-legged could be achieved by 23 (85%) of the loosened knees, but only 22 (49%) of the well-fixed knees (chi-squared test, p = 0.001). The loosened femoral components were found to migrate into a more flexed position, but no migration was detected in the well-fixed group. These implants allowed a high degree of flexion, but showed a marked rate of early loosening of the femoral component, which was associated with weight-bearing in maximum flexion.

  5. Deformation and Stress Response of Carbon Nanotubes/UHMWPE Composites under Extensional-Shear Coupling Flow

    NASA Astrophysics Data System (ADS)

    Wang, Junxia; Cao, Changlin; Yu, Dingshan; Chen, Xudong

    2018-02-01

    In this paper, the effect of varying extensional-shear couple loading on deformation and stress response of Carbon Nanotubes/ ultra-high molecular weight polyethylene (CNTs/UHMWPE) composites was investigated using finite element numerical simulation, with expect to improve the manufacturing process of UHMWPE-based composites with reduced stress and lower distortion. When applying pure extensional loading and pure X-Y shear loading, it was found that the risk of a structural breakage greatly rises. For identifying the coupling between extensional and shear loading, distinct generations of force loading were defined by adjusting the magnitude of extensional loading and X-Y shear loading. It was shown that with the decrement of X-Y shear loading the deformation decreases obviously where the maximal Mises stress in Z-direction at 0.45 m distance is in the range from 24 to 10 MPa and the maximal shear stress at 0.61 m distance is within the range from 0.9 to 0.3 MPa. In addition, all the stresses determined were clearly below the yield strength of CNTs/UHMWPE composites under extensional-shear couple loading.

  6. [Review and prospect of analysis on UHMWPE wear debris in artificial hip joints].

    PubMed

    Wu, Jingping; Yuan, Chengqing; Yan, Xinping

    2010-02-01

    This paper briefly reviews the latest progress in the analyses of the technologies for artificial hip joints; and in the researches directed to the features of UHMWPE debris obtained from all kinds of experimental conditions, to the wear process and wear mechanism, and to the factors which influence the wear mechanism. Furthermore, the signification of debris atlas was illustrated. Finally, future directions to be furthered were considered and envisaged. It is suggested that emphases be laid on the relationship between the UHMWPE debris feature and the wear mechanism, and be laid synergistic effects of biochemical environment and loading environment so as to establish the predictive wear models of artificial hip joints.

  7. Tribological behaviors of UHMWPE composites with different counter surface morphologies

    NASA Astrophysics Data System (ADS)

    Wang, Yanzhen; Yin, Zhongwei; Li, Hulin; Gao, Gengyuan

    2017-12-01

    The influence of counter surface morphologies on hybrid glass fiber (GF) and carbon fiber (CF) filled ultrahigh molecular weight polyethylene (UHMWPE) were studied under various contact pressure and sliding speed against GCr15 steel in dry condition. The goals were to investigate the tribological behavior of GF/CF/UHMWPE composite as a kind of water lubricated journal bearing material. The friction and wear behavior of composites were examined using a pin-on-disc tribometer. The morphologies of the worn surface were examined by scanning electron microscopy (SEM) and laser 3D micro-imaging and profile measurement. Generally, the wear rate and friction coefficient of composites increase as the increment of counter surface roughness. The friction coefficient increases firstly and then decrease with an increase in sliding speed and contact pressure for counterface with Ra=0.2 and 3.5 μm, while the friction coefficient decreased for counterface with Ra=0.6 μm.

  8. PMMA Third-Body Wear after Unicondylar Knee Arthroplasty Decuples the UHMWPE Wear Particle Generation In Vitro

    PubMed Central

    Paulus, Alexander Christoph; Franke, Manja; Kraxenberger, Michael; Schröder, Christian; Jansson, Volkmar

    2015-01-01

    Introduction. Overlooked polymethylmethacrylate after unicondylar knee arthroplasty can be a potential problem, since this might influence the generated wear particle size and morphology. The aim of this study was the analysis of polyethylene wear in a knee wear simulator for changes in size, morphology, and particle number after the addition of third-bodies. Material and Methods. Fixed bearing unicondylar knee prostheses (UKA) were tested in a knee simulator for 5.0 million cycles. Following bone particles were added for 1.5 million cycles, followed by 1.5 million cycles with PMMA particles. A particle analysis by scanning electron microscopy of the lubricant after the cycles was performed. Size and morphology of the generated wear were characterized. Further, the number of particles per 1 million cycles was calculated for each group. Results. The particles of all groups were similar in size and shape. The number of particles in the PMMA group showed 10-fold higher values than in the bone and control group (PMMA: 10.251 × 1012; bone: 1.145 × 1012; control: 1.804 × 1012). Conclusion. The addition of bone or PMMA particles in terms of a third-body wear results in no change of particle size and morphology. PMMA third-bodies generated tenfold elevated particle numbers. This could favor an early aseptic loosening. PMID:25866795

  9. Stiffness after total knee arthroplasty: does component alignment differ in knees requiring manipulation? A retrospective cohort study of 281 patients.

    PubMed

    Harvie, Paul; Larkin, James; Scaddan, Matt; Longstaff, Lee M; Sloan, Karen; Beaver, Richard J

    2013-01-01

    This study aims to evaluate component alignment in a large cohort of total knee arthroplasties (TKAs) and ascertain whether alignment in TKAs undergoing postoperative manipulation under anesthetic is significantly different from those achieving good function. A retrospective review of 281 consecutive primary TKAs was performed. All TKAs underwent computed tomographic scanning (Perth computed tomography knee protocol). Of 281 TKAs, 21 (7.4%) underwent manipulation, performed at a mean of 8.1 weeks (range, 3-14 weeks) after surgery. No statistically significant difference was seen between groups for any of 12 parameters of alignment. Postoperative stiffness with the need for manipulation under anesthetic is multifactorial in origin. This study found insufficient evidence to support the theory that component alignment contributes significantly to the etiology of this difficult problem. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  10. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    PubMed

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  11. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    PubMed Central

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  12. Does a minimally invasive approach affect positioning of components in unicompartmental knee arthroplasty? Early results with survivorship analysis.

    PubMed

    Cool, Steve; Victor, Jan; De Baets, Thierry

    2006-12-01

    Fifty unicompartmental knee arthroplasties (UKAs) were performed through a minimally invasive approach and were reviewed with an average follow-up of 3.7 years. This technique leads to reduced access to surgical landmarks. The purpose of this study was to evaluate whether correct component positioning is possible through this less invasive approach. Component positioning, femorotibial alignment and early outcomes were evaluated. We observed perfect tibial component position, but femoral component position was less consistent, especially in the sagittal plane. Femorotibial alignment in the coronal plane was within 2.5 degrees of the desired axis for 80% of the cases. Femoral component position in the sagittal plane was within a 10 degrees range of the ideal for 70% of the cases. The mean IKS Knee Function Score and Knee Score were 89/100 and 91/100 respectively. We observed two polyethylene dislocations, and one revision was performed for progressive patellofemoral arthrosis. According to our data, minimally invasive UKA does not conflict with component positioning although a learning curve needs to be respected, with femoral component positioning as the major obstacle.

  13. Fractography evolution in accelerated aging of UHMWPE after gamma irradiation in air.

    PubMed

    Medel, F; Gómez-Barrena, E; García-Alvarez, F; Ríos, R; Gracia-Villa, L; Puértolas, J A

    2004-01-01

    We studied the fracture surface evolution of ultra high molecular weight polyethylene (UHMWPE) specimens, manufactured from GUR 1050 compression moulded sheets, after gamma sterilisation in air followed by different aging times after thermal treatment at 120 degrees C. Degradation profiles were obtained by FTIR and DSC measurements after 0, 7, 14, 24 and 36h aging. We observed by SEM the morphology patterns at these aging times, in surface fractographies after uniaxial tensile test of standardised samples. The results pointed out clear differences between short and long aging times. At shorter times, 7h, the behaviour was similar to non-degraded UHMWPE, exhibiting ductile behaviour. At longer times, 24-36h, this thermal protocol provided a highly degraded zone in the subsurface, similar to the white band found after gamma irradiation in air followed by natural aging, although closer to the surface, at 150-200mum. The microstructure of this oxidation zone, similarly found in gamma irradiated samples shelf-aged for 6-7 years, although with different distribution of microvoids, was formed by fibrils, associated with embrittlement of the oxidised UHMWPE. In addition, the evolution of the oxidation index, the enthalpy content, the mechanical parameters, and the depth of the oxidation front deduced from the fractographies versus aging time showed that a changing behaviour in the degradation rate appeared at intermediate aging times.

  14. Variation of mechanical properties and oxidation with radiation dose and source in highly crosslinked remelted UHMWPE.

    PubMed

    Fung, Mitchell; Bowsher, John G; Van Citters, Douglas W

    2018-06-01

    Ultra-high molecular weight polyethylene (UHMWPE) is the current gold standard for bearing materials used in total joint arthroplasty. High-dose radiation is commonly used to crosslink UHMWPE, thereby improving its wear resistance. A subsequent remelting step eliminates trapped residual free radicals to promote oxidative stability on the shelf, and to prevent material degradation over the long term. Assessment of clinically retrieved, highly crosslinked UHMWPE devices shows signs of unanticipated oxidation occurring in vivo, despite the absence of free radicals prior to implantation. These findings warrant further investigation into possible factors impacting this phenomenon along with its clinical implications. The overall objective of this work is to quantify the influence of irradiation dose and source on UHMWPE's oxidative stability, along with the effects of oxidation on the ultimate mechanical properties, including strength, ductility, and toughness. The results showed a strong positive correlation between maximum oxidation and initial transvinylene content. Critical oxidation levels in the context of mechanical property loss were determined for e-beam and gamma treatments at various radiation doses. Further, it was shown that critical oxidation was more dependent on radiation dose and less dependent on source. If in vivo oxidation persists in these devices, this can potentially lead to mechanical failure (e.g. fatigue damage) as observed in terminally gamma-sterilized devices. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Evaluation of carbon nanotubes and graphene as reinforcements for UHMWPE-based composites in arthroplastic applications: A review.

    PubMed

    Puértolas, J A; Kurtz, S M

    2014-11-01

    In this review we have evaluated the state of the art of CNT/UHMWPE and graphene/UHMWPE composites from four different points of view: mechanical properties, chemical stability, wear resistance and biocompatibility. The performance of these new carbonaceous composites allows us to conclude that these materials have overcome a first step on the way to developing into an alternative to the current HXLPEs used in orthopedic applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation.

    PubMed

    Jahan, M S; Wang, C; Schwartz, G; Davidson, J A

    1991-08-01

    An electron spin resonance (ESR) technique is employed to determine the free radical distribution in the articulating surfaces of retrieved acetabular cups and knee-joint plateaus (retrieved after more than 6 years of implantation). Similar measurements made on samples prepared from cyclically stressed and unstressed cups, and on samples following oxidations in nitric acid and intralipid solutions provided sufficient data to gain more knowledge about the combined chemical and mechanical effects on PE free radicals during implantation. In UHMWPE free radicals are primarily initiated by gamma-ray sterilization; however, during implantation, peroxy (scission type) free radicals are formed and reach a maximum concentration level (equilibrium state) due to oxidation by chemical (hemoglobin and/or synovial fluids) environment of the joints. Subsequently, due to frictional heating and stress in the loading zones, free radical reaction is accelerated and their number is reduced only in those areas. This is consistent with the observations of a temperature rise in acetabular cups during in vitro frictional wear stress tests and in vivo telemetry observations, as reported by others. Compared with the previously reported SEM micrographs the low-free-radical regions are correlated with high-wear areas and the high-free-radical regions with the low-wear areas.

  17. Contact Kinematics Correlates to Tibial Component Migration Following Single Radius Posterior Stabilized Knee Replacement.

    PubMed

    Teeter, Matthew G; Perry, Kevin I; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-03-01

    Contact kinematics between total knee arthroplasty components is thought to affect implant migration; however, the interaction between kinematics and tibial component migration has not been thoroughly examined in a modern implant system. A total of 24 knees from 23 patients undergoing total knee arthroplasty with a single radius, posterior stabilized implant were examined. Patients underwent radiostereometric analysis at 2 and 6 weeks, 3 and 6 months, and 1 and 2 years to measure migration of the tibial component in all planes. At 1 year, patients also had standing radiostereometric analysis examinations acquired in 0°, 20°, 40°, and 60° of flexion, and the location of contact and magnitude of any condylar liftoff was measured for each flexion angle. Regression analysis was performed between kinematic variables and migration at 1 year. The average magnitude of maximum total point motion across all patients was 0.671 ± 0.270 mm at 1 year and 0.608 ± 0.359 mm at 2 years (P = .327). Four implants demonstrated continuous migration of >0.2 mm between the first and second year of implantation. There were correlations between the location of contact and tibial component anterior-posterior tilt, varus-valgus tilt, and anterior-posterior translation. The patients with continuous migration demonstrated atypical kinematics and condylar liftoff in some instances. Kinematics can influence tibial component migration, likely through alterations of force transmission. Abnormal kinematics may play a role in long-term implant loosening. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Comparison of two tension-band fixation materials and techniques in transverse patella fractures: a biomechanical study.

    PubMed

    Rabalais, R David; Burger, Evalina; Lu, Yun; Mansour, Alfred; Baratta, Richard V

    2008-02-01

    This study compared the biomechanical properties of 2 tension-band techniques with stainless steel wire and ultra high molecular weight polyethylene (UHMWPE) cable in a patella fracture model. Transverse patella fractures were simulated in 8 cadaver knees and fixated with figure-of-8 and parallel wire configurations in combination with Kirschner wires. Identical configurations were tested with UHMWPE cable. Specimens were mounted to a testing apparatus and the quadriceps was used to extend the knees from 90 degrees to 0 degrees; 4 knees were tested under monotonic loading, and 4 knees were tested under cyclic loading. Under monotonic loading, average fracture gap was 0.50 and 0.57 mm for steel wire and UHMWPE cable, respectively, in the figure-of-8 construct compared with 0.16 and 0.04 mm, respectively, in the parallel wire construct. Under cyclic loading, average fracture gap was 1.45 and 1.66 mm for steel wire and UHMWPE cable, respectively, in the figure-of-8 construct compared with 0.45 and 0.60 mm, respectively, in the parallel wire construct. A statistically significant effect of technique was found, with the parallel wire construct performing better than the figure-of-8 construct in both loading models. There was no effect of material or interaction. In this biomechanical model, parallel wires performed better than the figure-of-8 configuration in both loading regimens, and UHMWPE cable performed similarly to 18-gauge steel wire.

  19. Modeling Ballistic Response of Ultra-High-Molecular-Weight Polyethylene (UHMWPE)

    DTIC Science & Technology

    2016-07-01

    posttest panels. Fig. 5 Variables to be compared between model and experiments The 6 tests and available test data are listed in Table 2. The first 3...Time history of center BFD for the 3 BFD tests Figure 24 shows the damages in the panels from posttest CT scan of the UHMWPE panels and the

  20. Mechanical properties and biocompatibility of melt processed, self-reinforced ultrahigh molecular weight polyethylene.

    PubMed

    Huang, Yan-Fei; Xu, Jia-Zhuang; Li, Jian-Shu; He, Ben-Xiang; Xu, Ling; Li, Zhong-Ming

    2014-08-01

    The low efficiency of fabrication of ultrahigh molecular weight polyethylene (UHMWPE)-based artificial knee joint implants is a bottleneck problem because of its extremely high melt viscosity. We prepared melt processable UHMWPE (MP-UHMWPE) by addition of 9.8 wt% ultralow molecular weight polyethylene (ULMWPE) as a flow accelerator. More importantly, an intense shear flow was applied during injection molding of MP-UHMWPE, which on one hand, promoted the self-diffusion of UHMWPE chains, thus effectively reducing the structural defects; on the other hand, increased the overall crystallinity and induced the formation of self-reinforcing superstructure, i.e., interlocked shish-kebabs and oriented lamellae. Aside from the good biocompatibility, and the superior fatigue and wear resistance to the compression-molded UHMWPE, the injection-molded MP-UHMWPE exhibits a noteworthy enhancement in tensile properties and impact strength, where the yield strength increases to 46.3 ± 4.4 MPa with an increment of 128.0%, the ultimate tensile strength and Young's modulus rise remarkably up to 65.5 ± 5.0 MPa and 1248.7 ± 45.3 MPa, respectively, and the impact strength reaches 90.6 kJ/m(2). These results suggested such melt processed and self-reinforced UHMWPE parts hold a great application promise for use of knee joint implants, particularly for younger and more active patients. Our work sets up a new method to fabricate high-performance UHMWPE implants by tailoring the superstructure during thermoplastic processing. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

    PubMed

    Pourzal, Robin; Knowlton, Christopher B; Hall, Deborah J; Laurent, Michel P; Urban, Robert M; Wimmer, Markus A

    2016-08-01

    The longevity of total hip (THR) and knee replacements (TKR) that used historical bearing materials of gamma-in-air sterilized UHMWPE was affected more by osteolysis in THRs than in TKRs, although osteolysis remains a concern in TKRs. Therefore, the study of polyethylene wear is still of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. The acetabular liners of the

  2. Mid-term results of total knee arthroplasty with a porous tantalum monoblock tibial component.

    PubMed

    Hayakawa, Kazue; Date, Hideki; Tsujimura, Shunzo; Nojiri, Sho; Yamada, Harumoto; Nakagawa, Kenji

    2014-01-01

    The objectives of the present study were to assess the mid-term results of cementless total knee arthroplasty (TKA) with the porous tantalum monoblock tibial component and to examine the time course of bone changes on plain radiographs. The subjects were 32 patients, 29 patients were available for follow-up. We investigated the mid-term results of TKA after a mean follow-up period of 7 years and 8 months. We also examined changes of the bone over time on plain radiographs. The Knee Society Clinical Rating scores showed significant improvement. Bone changes around the tibial component were as follows: new bone formation and longitudinal trabecular thickening in 41.4% (Type A), only longitudinal trabecular thickening in 41.4% (Type B), and no changes in 17.2% (Type C). Type A and B changes were more frequent in patients with osteoarthritis, whereas Type C was only seen in patients with rheumatoid arthritis. Three knees had an initial gap, but this disappeared in all cases, and no new radiolucent lines were detected. Stress shielding was observed in seven knees (21.9%), but there was no implant loosening related to it. When we examined the relationship between the mechanical axis and the locations of the tips of the tibial pegs in patients with or without stress shielding, no significant differences were found. The results of mid-term follow-up have demonstrated favorable bone ingrowth, suggesting that porous tantalum is a promising material for cementless TKA. © 2013.

  3. Outcomes of Articulating Spacers With Autoclaved Femoral Components in Total Knee Arthroplasty Infection.

    PubMed

    Goltz, Daniel E; Sutter, E Grant; Bolognesi, Michael P; Wellman, Samuel S

    2018-03-30

    In 2-stage revision of total knee arthroplasty (TKA) infection, articulating antibiotic spacers show similar eradication rates and superior range of motion compared with static spacers. This study evaluated infection control and other outcomes in articulating spacers with an autoclaved index femoral component. We reviewed 59 patients who underwent 2-stage treatment of TKA infection using articulating antibiotic spacers with an autoclaved femoral component with at least 2-year follow-up (mean: 5.0 years) from spacer placement. Reinfection was defined as any subsequent infection; recurrence was defined as reinfection with the same organism, need for chronic antibiotics, or conversion directly to amputation/arthrodesis. Nine patients (15%) experienced a recurrence and 22 patients (37%) experienced a reinfection. Incidence of diabetes mellitus was significantly higher in patients who became reinfected. Other comorbidities, revision history, prior spacer, or presence of virulent organisms did not predict infection recurrence. Forty-seven spacers underwent reimplantation, 6 (13%) of these went on to above-knee amputation, 6 (13%) received another 2-stage procedure, and 3 (6%) underwent subsequent irrigation and debridement. Three patients (5%) proceeded directly from spacer to above-knee amputation (2) or arthrodesis (1). Nine spacers (15%) in 7 patients were retained indefinitely (mean: 3.4 years), with overall good motion and function. Accounting for methodology, articulating spacers with autoclaved femoral components provide similar infection control to previous reports. Most patients with reinfection grew different organisms compared with initial infection, suggesting that some subsequent infections may be host related. Some patients retained spacers definitively with overall good patient satisfaction. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Arthroscopic observation was useful to detect loosening of the femoral component of unicompartmental knee arthroplasty in a recurrent hemoarthrosis

    PubMed Central

    2012-01-01

    A case of recurrent hemarthrosis of the knee after a mobile-bearing unicompartmental knee arthroplasty (UKA; Oxford UKA) is described. A 58-year-old man met with a road traffic accident 10 months after UKA. He developed anteromedial pain and hemarthrosis of the knee joint 1 month after the accident, which required multiple aspirations. Physical examination showed no instability. Plain radiograph revealed no signs of loosening. All laboratory data, including bleeding and coagulation times, were within normal limits. Diagnostic arthroscopy demonstrated loosening of the femoral component. Any intraarticular pathology other than nonspecific synovitis was ruled out. The loose femoral component and polyethylene meniscal bearing were revised. Since then, hemarthrosis has not recurred. PMID:22353541

  5. Alignment and component position after patient-matched instrumentation versus conventional total knee arthroplasty.

    PubMed

    Pourgiezis, N; Reddy, S P; Nankivell, M; Morrison, G; VanEssen, J

    2016-08-01

    To compare patient-matched instrumentation (PMI) with conventional total knee arthroplasty (TKA) in terms of limb alignment and component position. Nine men and 36 women (mean age, 69.5 years) who underwent PMI TKA were compared with 20 men and 25 women (mean age, 69.3 years) who underwent conventional TKA by the same team of surgeons with the same prosthesis and protocols in terms of limb alignment and component position using the Perth protocol computed tomography, as well as bone resection measurements, operating time, and the number of trays used. The PMI and conventional TKA groups were comparable in terms of age, body mass index, tourniquet time, operating time, and the number of trays used. For limb alignment and component position, the 2 groups differed significantly in sagittal femoral component position (2.4º vs. 0.9º, p=0.0008) and the percentage of knees with femoral component internally rotated ≥1° with respect to the transepicondylar axis (20% vs. 55%, p=0.001). The difference was not significant in terms of limb alignment, coronal and rotational femoral component position, or coronal and sagittal tibial component position. Intra-operatively, all patient-matched cutting blocks demonstrated acceptable fit and stability. No instrument-related adverse events or complications were encountered. One (2.2%) femur and 6 (13.3%) tibiae were recut 2 mm for optimal ligament balancing. Two femoral components were upsized to the next size, and 2 tibial components were upsized and 2 downsized to the next size. PMI was as accurate as conventional instrumentation in TKA. There was no significant difference in limb alignment or femoral and tibial component position in the coronal and sagittal planes between PMI and conventional TKA. PMI had a higher tendency to achieve correct femoral component rotation.

  6. Identifying changes in gait waveforms following a strengthening intervention for women with knee osteoarthritis using principal components analysis.

    PubMed

    Brenneman, Elora C; Maly, Monica R

    2018-01-01

    Lower limb strengthening exercise is pivotal for the management of symptoms related to knee osteoarthritis (OA). Though improvement in clinical symptoms is well documented, concurrent changes in gait biomechanics are ill-defined. This may occur because discrete analyses miss changes following an intervention, analyses limited to the knee undermine potential mechanical trade-offs at other joints, or strengthening interventions not been designed based on biomechanical principles. The purpose of this study was to characterize differences in entire gait waveforms for sagittal plane ankle, knee, and hip angles and external moments; the knee adduction moment; and frontal plane hip angle and moment following 12-weeks of a previously designed novel lower limb strengthening program. Forty women with knee OA completed two laboratory visits: one at baseline and one immediately following intervention (follow-up). Self-report measures, strength, and gait analyses were completed at each visit. Principal components analyses were completed for sagittal angles and external moments at the ankle, knee, and hip joints, as well as frontal plane angle and moment for the hip. Participants improved self-report and strength (p≤0.004). Two significant, yet subtle differences in principal components were identified between baseline and follow-up waveforms (p<0.05) pertaining to the knee and hip sagittal external moments. The subtle changes in concert with the lack of differences in other joints and planes suggest the lower limb strengthening program does not translate to changes in the gait waveform. It is likely this program is improving symptoms without worsening mechanics. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

    PubMed

    Minoda, Yukihide; Hata, Kanako; Iwaki, Hiroyoshi; Ikebuchi, Mitsuhiko; Hashimoto, Yusuke; Inori, Fumiaki; Nakamura, Hiroaki

    2014-03-01

    Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 μm in the case of oxidized zirconium and 0.6 ± 0.1 μm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. Therapeutic study, Level III.

  8. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  9. Nucleation and growth of apatite on NaOH-treated PEEK, HDPE and UHMWPE for artificial cornea materials.

    PubMed

    Pino, M; Stingelin, N; Tanner, K E

    2008-11-01

    The skirt of an artificial cornea must integrate the implant to the host sclera, a major failure of present devices. Thus, it is highly desirable to encourage the metabolic activity of the cornea by using more bioactive, flexible skirt materials. Here we describe attempts to increase the bioactivity of polyether ether ketone (PEEK), high-density polyethylene (HDPE) and ultra-high molecular weight polyethylene (UHMWPE) films. The effectiveness of different strength NaOH pre-treatments to initiate apatite deposition on PEEK, HDPE and UHMWPE is investigated. We find that exposure of PEEK, HDPE and UHMWPE films to NaOH solutions induces the formation of potential nuclei for apatite (calcium phosphate), from which the growth of an apatite coating is stimulated when subsequently immersing the polymer films in 1.5 strength Simulated Body Fluid (SBF). As immersion time in SBF increases, further nucleation and growth produces a thicker and more compact apatite coating that can be expected to be highly bioactive. Interestingly, the apatite growth is found to also be dependent on both the concentration of NaOH solution and the structure of the polymer surface.

  10. [Ligament-controlled positioning of the knee prosthesis components].

    PubMed

    Widmer, K-H; Zich, A

    2015-04-01

    There are at least two predominant goals in total knee replacement: first, the surgeon aims to achieve an optimal postoperative kinematic motion close to the patient's physiological range, and second, he aims for concurrent high ligament stability to establish pain-free movement for the entire range of motion. A number of prosthetic designs and surgical techniques have been developed in recent years to achieve both of these targets. This study presents another modified surgical procedure for total knee implantation. As in common practice the osteotomies are planned preoperatively, referencing well-defined bony landmarks, but their placement and orientation are also controlled intraoperatively in a stepwise sequence via ligamentous linkages. This method is open to all surgical approaches and can be applied for PCL-conserving or -sacrificing techniques. The anterior femoral osteotomy is carried out first, followed by the distal femoral osteotomy. Then, the extension gap is finalized by tensioning the ligaments and "top-down" referencing at the level of the tibial osteotomy, followed by finishing the flexion gap in the same way, except that the osteotomy of the posterior condyles is referenced in a "bottom-up" fashion. Hence, this technique relies on both bony and ligament-controlled procedures. Thus, it respects the modified ligamentous framework and drives the prosthetic components into the new ligamentous envelope. Further improvement may be achieved by additional control of the kinematics during surgery by applying modern computer navigation technology.

  11. Mechanical properties of HDPE/UHMWPE blends: effect of filler loading and filler treatment.

    PubMed

    Lai, K L K; Roziyanna, A; Ogunniyi, D S; Zainal, Arifin M I; Azlan, Ariffin A

    2004-05-01

    Various blend ratios of high-density polyethylene (HDPE) and ultra high molecular weight polyethylene (UHMWPE) were prepared with the objective of determining their suitability as biomaterials. In the unfilled state, a blend of 50/50 (HDPE/UHMWPE) ratio by weight was found to yield optimum properties in terms of processability and mechanical properties. Hydroxyapatite (HA) was compounded with the optimum blend ratio. The effects of HA loading, varied from 0 to 50wt% for both filled and unfilled blends were tested for mechanical properties. It was found that the inclusion of HA in the blend led to a remarkable improvement of mechanical properties compared to the unfilled blend. In order to improve the bonding between the polymer blend and the filler, the HA used was chemically treated with a coupling agent known as 3-(trimethoxysiyl) propyl methacrylate and the treated HA was mixed into the blend. The effect of mixing the blend with silane-treated HA also led to an overall improvement of mechanical properties.

  12. Principal Component Analysis in Construction of 3D Human Knee Joint Models Using a Statistical Shape Model Method

    PubMed Central

    Tsai, Tsung-Yuan; Li, Jing-Sheng; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Li, Guoan

    2013-01-01

    The statistical shape model (SSM) method that uses 2D images of the knee joint to predict the 3D joint surface model has been reported in literature. In this study, we constructed a SSM database using 152 human CT knee joint models, including the femur, tibia and patella and analyzed the characteristics of each principal component of the SSM. The surface models of two in vivo knees were predicted using the SSM and their 2D bi-plane fluoroscopic images. The predicted models were compared to their CT joint models. The differences between the predicted 3D knee joint surfaces and the CT image-based surfaces were 0.30 ± 0.81 mm, 0.34 ± 0.79 mm and 0.36 ± 0.59 mm for the femur, tibia and patella, respectively (average ± standard deviation). The computational time for each bone of the knee joint was within 30 seconds using a personal computer. The analysis of this study indicated that the SSM method could be a useful tool to construct 3D surface models of the knee with sub-millimeter accuracy in real time. Thus it may have a broad application in computer assisted knee surgeries that require 3D surface models of the knee. PMID:24156375

  13. Effect of lubricant composition on the fatigue properties of ultra-high molecular weight polyethylene for total knee replacement.

    PubMed

    Aurora, A; DesJardins, J D; Joseph, P F; LaBerge, M

    2006-05-01

    Ultrahigh molecular weight polyethylene (UHMWPE) fatigue is a critical factor affecting the longevity of total knee replacement (TKR) bearings. With the increased need for laboratory studies to mimic near in vivo conditions for accurate characterization of material performance, the present study investigated the role of hyaluronic acid (HA) in testing lubricant on the crack growth response of UHMWPE. It was hypothesized that the change in lubricant viscosity as a result of HA would affect the fatigue life of the polymer. A fracture mechanics approach as per ASTM E 647 was adopted for this study. Surface micrograph and surface chemistry analyses were employed to study the micromechanisms of fatigue failure and protein adsorption of the specimen surfaces. Rheological analysis indicated that the addition of HA to diluted bovine serum increased testing lubricant viscosity. HA concentrations of 2.22, 0.55, and 1.5 g/l closely matched the viscosity ranges reported for osteoarthritis, rheumatoid arthritic diseased joint fluid, and periprosthetic fluids respectively. Results showed that the addition of HA to standard diluted bovine serum lubricants, in concentrations similar to that of periprosthetic fluid, delayed crack initiation and crack growth during fatigue testing.

  14. Principal component analysis in construction of 3D human knee joint models using a statistical shape model method.

    PubMed

    Tsai, Tsung-Yuan; Li, Jing-Sheng; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Li, Guoan

    2015-01-01

    The statistical shape model (SSM) method that uses 2D images of the knee joint to predict the three-dimensional (3D) joint surface model has been reported in the literature. In this study, we constructed a SSM database using 152 human computed tomography (CT) knee joint models, including the femur, tibia and patella and analysed the characteristics of each principal component of the SSM. The surface models of two in vivo knees were predicted using the SSM and their 2D bi-plane fluoroscopic images. The predicted models were compared to their CT joint models. The differences between the predicted 3D knee joint surfaces and the CT image-based surfaces were 0.30 ± 0.81 mm, 0.34 ± 0.79 mm and 0.36 ± 0.59 mm for the femur, tibia and patella, respectively (average ± standard deviation). The computational time for each bone of the knee joint was within 30 s using a personal computer. The analysis of this study indicated that the SSM method could be a useful tool to construct 3D surface models of the knee with sub-millimeter accuracy in real time. Thus, it may have a broad application in computer-assisted knee surgeries that require 3D surface models of the knee.

  15. Modifying friction between ultra-high molecular weight polyethylene (UHMWPE) yarns with plasma enhanced chemical vapour deposition (PCVD)

    NASA Astrophysics Data System (ADS)

    Chu, Yanyan; Chen, Xiaogang; Tian, Lipeng

    2017-06-01

    Ultra-high molecular weight polyethylene (UHMWPE) yarns are widely used in military applications for protection owing to its high modulus and high strength; however, the friction between UHMWPE yarns is too small, which is a weakness for ballistic applications. The purpose of current research is to increase the friction between UHMWPE yarns by plasma enhanced chemical vapour deposition (PCVD). The changes of morphology and chemical structure were characterised by SEM and FTIR individually. The coefficients of friction between yarns were tested by means of Capstan method. Results from tests showed that the yarn-yarn coefficient of static friction (CSF) has been improved from 0.12 to 0.23 and that of kinetic friction (CSF) increased from 0.11 to 0.19, as the samples exposure from 21 s to 4 min. The more inter-yarn friction can be attributed to more and more particles and more polar groups deposited on the surfaces of yarns, including carboxyl, carbonyl, hydroxyl and amine groups and compounds containing silicon. The tensile strength and modulus of yarns, which are essential to ballistic performance, keep stable and are not affected by the treatments, indicating that PCVD treatment is an effective way to improve the inter-yarn friction without mechanical property degradation.

  16. Factors affecting the achievement of Japanese-style deep knee flexion after total knee arthroplasty using posterior-stabilized prosthesis with high-flex knee design.

    PubMed

    Niki, Yasuo; Takeda, Yuki; Harato, Kengo; Suda, Yasunori

    2015-11-01

    Achievement of very deep knee flexion after total knee arthroplasty (TKA) can play a critical role in the satisfaction of patients who demand a floor-sitting lifestyle and engage in high-flexion daily activities (e.g., seiza-sitting). Seiza-sitting is characterized by the knees flexed >145º and feet turned sole upwards underneath the buttocks with the tibia internally rotated. The present study investigated factors affecting the achievement of seiza-sitting after TKA using posterior-stabilized total knee prosthesis with high-flex knee design. Subjects comprised 32 patients who underwent TKA with high-flex knee prosthesis and achieved seiza-sitting (knee flexion >145º) postoperatively. Another 32 patients served as controls who were capable of knee flexion >145º preoperatively, but failed to achieve seiza-sitting postoperatively. Accuracy of femoral and tibial component positions was assessed in terms of deviation from the ideal position using a two-dimensional to three-dimensional matching technique. Accuracies of the component position, posterior condylar offset ratio and intraoperative gap length were compared between the two groups. The proportion of patients with >3º internally rotated tibial component was significantly higher in patients who failed at seiza-sitting (41 %) than among patients who achieved it (13 %, p = 0.021). Comparison of intraoperative gap length between patient groups revealed that gap length at 135º flexion was significantly larger in patients who achieved seiza-sitting (4.2 ± 0.4 mm) than in patients who failed at it (2.7 ± 0.4 mm, p = 0.007). Conversely, no significant differences in gap inclination were seen between the groups. From the perspective of surgical factors, accurate implant positioning, particularly rotational alignment of the tibial component, and maintenance of a sufficient joint gap at 135º flexion appear to represent critical factors for achieving >145º of deep knee flexion after TKA.

  17. Component alignment in revision total knee arthroplasty using diaphyseal engaging modular offset press-fit stems.

    PubMed

    Nakasone, Cass K; Abdeen, Ayesha; Khachatourians, Armond G; Sugimori, Tanzo; Vince, Kelly G

    2008-12-01

    We performed a retrospective study of the radiographic position of femoral and tibial components in a series of revision total knee arthroplasties using diaphyseal-engaging, press fit, modular stems. Fifty-two consecutive revision cases were performed. Femoral and tibial component alignment was measured preoperatively and postoperatively. The canal-filling ratio was measured and correlated with anatomic alignment. There was a trend toward improved alignment with increasing canal fill, suggesting that uncemented diaphyseal engaging press-fit modular stems facilitate accurate alignment for both femoral and tibial components in revision surgery.

  18. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

    PubMed

    Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian

    2008-03-01

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all

  19. Postoperative Knee Flexion Angle Is Affected by Lateral Laxity in Cruciate-Retaining Total Knee Arthroplasty.

    PubMed

    Nakano, Naoki; Matsumoto, Tomoyuki; Muratsu, Hirotsugu; Takayama, Koji; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-02-01

    Although many studies have reported that postoperative knee flexion is influenced by preoperative conditions, the factors which affect postoperative knee flexion have not been fully elucidated. We tried to investigate the influence of intraoperative soft tissue balance on postoperative knee flexion angle after cruciate-retaining (CR) total knee arthroplasty (TKA) using a navigation and an offset-type tensor. We retrospectively analyzed 55 patients with osteoarthritis who underwent TKA using e.motion-CR (B. Braun Aesculap, Germany) whose knee flexion angle could be measured at 2 years after operation. The exclusion criteria included valgus deformity, severe bony defect, infection, and bilateral TKA. Intraoperative varus ligament balance and joint component gap were measured with the navigation (Orthopilot 4.2; B. Braun Aesculap) while applying 40-lb joint distraction force at 0° to 120° of knee flexion using an offset-type tensor. Correlations between the soft tissue parameters and postoperative knee flexion angle were analyzed using simple linear regression models. Varus ligament balance at 90° of flexion (R = 0.56; P < .001) and lateral compartment gap at 90° of flexion (R = 0.51; P < .001) were positively correlated with postoperative knee flexion angle. In addition, as with past studies, joint component gap at 90° of flexion (R = 0.30; P < .05) and preoperative knee flexion angle (R = 0.63; P < .001) were correlated with postoperative knee flexion angle. Lateral laxity as well as joint component gap at 90° of flexion is one of the most important factors affecting postoperative knee flexion angle in CR-TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Femoral Component Sizing in Oxford Unicompartmental Knee Replacement: Existing Guidelines Do Not Work for Indian Patients.

    PubMed

    Malhotra, Rajesh; Gaba, Sahil; Wahal, Naman; Kumar, Vijay; Srivastava, Deep N; Pandit, Hemant

    2018-02-28

    Oxford unicompartmental knee replacement (OUKR) has shown excellent long-term clinical outcomes as well as implant survival when used for correct indications with optimal surgical technique. Anteromedial osteoarthritis is highly prevalent in Indian patients, and OUKR is the ideal treatment option in such cases. Uncertainty prevails about the best method to determine femoral component size in OUKR. Preoperative templating has been shown to be inaccurate, while height- and gender-based guidelines based on European population might not apply to the Indian patients. Microplasty instrumentation introduced in 2012 introduced the sizing spoon, which has the dual function of femoral component sizing and determining the level of tibia cut. We aimed to check the accuracy of sizing spoon and also to determine whether the present guidelines are appropriate for use in the Indian patients. A total of 130 consecutive Oxford mobile bearing medial cemented UKR performed using the Microplasty instrumentation were included. The ideal femoral component size for each knee was recorded by looking for overhang and underhang in post-operative lateral knee radiograph. The accuracy of previous guidelines was determined by applying them to our study population. Previously published guidelines (which were based on Western population) proved to be accurate in only 37% of cases. Hence, based on the demographics of our study population, we formulated modified height- and gender-based guidelines, which would better suit the Indian population. Accuracy of modified guidelines was estimated to be 74%. The overall accuracy of sizing spoon (75%), when used as an intraoperative guide, was similar to that of modified guidelines. Existing guidelines for femoral component sizing do not work in Indian patients. Modified guidelines and use of intraoperative spoon should be used to choose the optimal implant size while performing OUKR in Indian patients. Thieme Medical Publishers 333 Seventh Avenue, New York

  1. Preparation and characterization of CNTs/UHMWPE nanocomposites via a novel mixer under synergy of ultrasonic wave and extensional deformation.

    PubMed

    Yin, Xiaochun; Li, Sai; He, Guangjian; Feng, Yanhong; Wen, Jingsong

    2018-05-01

    In this work, design and development of a new melt mixing method and corresponding mixer for polymer materials were reported. Effects of ultrasonic power and sonication time on the carbon nanotubes (CNTs) filled ultra high molecular weight polyethylene (UHMWPE) nanocomposites were experimentally studied. Transmission Electron Microscopy images showed that homogeneous dispersion of CNTs in intractable UHMWPE matrix is successfully realized due to the synergetic effect of ultrasonic wave and extensional deformation without any aid of other additives or solvents. Differential scanning calorimetry results revealed an increase in crystallinity and crystallization rate due to the finer dispersion of the CNTs in the matrix which act as nucleating point. Composites' complex viscosity and storage modulus decreased sharply at first and then leveled off with the increase of sonication time or the ultrasonic power. The thermal stability and the tensile strength of the CNTs/UHMWPE nanocomposites improved by using this novel mixing method. This is the first method that combined the ultrasonic wave and the extensional deformation in which the elongation rate, sonication time and ultrasonic power can be adjusted simultaneously during mixing. The novel mixer offers several advantages such as environment-friendly, high mixing efficiency, self-cleaning and wide adaptability to materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty--Chinese experience.

    PubMed

    Shen, Bin; Yang, Jing; Zhou, Zongke; Kang, Pengde; Wang, Liao; Pei, Fuxing

    2009-10-01

    Considering its cost saving, the all-polyethylene tibial component is of potential interest in developing countries like China. But to our knowledge, a survivorship comparison of all-polyethylene and metal-backed tibial components in posterior cruciate ligament-substituting total knee arthroplasty (PS-TKA) has not been studied in China previously. Using survivorship analysis, we have studied the midterm outcome of 34 cemented PS-TKA using an all-polyethylene tibial component and of 34 cemented PS-TKA using a metal-backed tibial component which has an identical articular surface with all-polyethylene tibial components. All operations were performed by the same group of surgeons; 58 patients underwent a unilateral operation and five patients a bilateral operation. These patients had a mean follow-up of 5.9 years (range: 5-7 years); three patients were lost to follow-up and one was revised for infection. No significant difference between the two groups was reported regarding HSS scores, ROM, clinical and radiographic parameters measured and survival rates. Although the Asian lifestyle includes more squatting and bending of the knee, the results of this series of TKA using all-polyethylene tibial components in Chinese people are comparable to the satisfactory results of other reported all-polyethylene series whose patients are mainly Western people. Considering its cost saving and excellent clinical result, the all-polyethylene tibial component is of potential interest in developing countries.

  3. CoCrMo alloy vs. UHMWPE Particulate Implant Debris Induces Sex Dependent Aseptic Osteolysis Responses In Vivo using a Murine Model

    PubMed Central

    Landgraeber, Stefan; Samelko, Lauryn; McAllister, Kyron; Putz, Sebastian; Jacobs, Joshua.J.; Hallab, Nadim James

    2018-01-01

    Background: The rate of revision for some designs of total hip replacements due to idiopathic aseptic loosening has been reported as higher for women. However, whether this is environmental or inherently sex-related is not clear. Objective: Can particle induced osteolysis be sex dependent? And if so, is this dependent on the type of implant debris (e.g. metal vs polymer)? The objective of this study was to test for material dependent inflammatory osteolysis that may be linked to sex using CoCrMo and implant grade conventional polyethylene (UHMWPE), using an in vivo murine calvaria model. Methods: Healthy 12 week old female and male C57BL/6J mice were treated with UHMWPE (1.0um ECD) or CoCrMo particles (0.9um ECD) or received sham surgery. Bone resorption was assessed by micro-computed tomography, histology and histomorphometry on day 12 post challenge. Results: Female mice that received CoCrMo particles showed significantly more inflammatory osteolysis and bone destruction compared to the females who received UHMWPE implant debris. Moreover, females challenged with CoCrMo particles exhibited 120% more inflammatory bone loss compared to males (p<0.01) challenged with CoCrMo implant debris (but this was not the case for UHMWPE particles). Conclusion: We demonstrated sex-specific differences in the amount of osteolysis resulting from CoCrMo particle challenge. This suggests osteo-immune responses to metal debris are preferentially higher in female compared to male mice, and supports the contention that there may be inherent sex related susceptibility to some types of implant debris. PMID:29785221

  4. Postural stability in patients with knee osteoarthritis: comparison with controls and evaluation of relationships between postural stability scores and International Classification of Functioning, Disability and Health components.

    PubMed

    Hsieh, Ru-Lan; Lee, Wen-Chung; Lo, Min-Tzu; Liao, Wei-Cheng

    2013-02-01

    To assess the differences in postural stability between patients with knee osteoarthritis and controls without knee osteoarthritis, and to evaluate possible relations between postural stability scores and International Classification of Functioning, Disability and Health (ICF) components. An age-matched, case-controlled trial with a cross-sectional design. A teaching hospital. Patients with knee osteoarthritis (n=73) and age-matched controls (n=60). Data on patients' postural stability and additional health-related variables were collected using various instruments. These included the Hospital Anxiety and Depression Scale, the Multidimensional Fatigue Inventory, the World Health Organization Quality of Life Brief Version, the physical function test (chair-rising time), the Chinese version of the Western Ontario and McMaster Universities Osteoarthritis Index, the Chinese version of the Knee Injury and Osteoarthritis Outcome Score, and the Biodex Stability System. A comparison of postural stability in patients with knee osteoarthritis versus that of controls was performed. The relation between postural stability scores for patients with knee osteoarthritis and ICF components was evaluated. Pearson correlation tests were used to determine the variables that correlated with postural stability among these patients. Patients with knee osteoarthritis displayed lower overall postural stability than controls (scores of 0.7 vs. 0.5, P=.006) and scored lower on the environmental domain of the World Health Organization Quality of Life Brief Version (62.2 vs 66.8, P=.014). For patients with knee osteoarthritis, postural stability was weakly associated with the ICF components of body functions and structures, including pain (r=.33-.34, P=.004), physical fatigue (r=.28, P=.016), and reduced motivation (r=.30, P=.011). Weak to moderate associations between postural stability and the ICF components of activities and participation were found; the relevant ICF variables included

  5. Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene.

    PubMed

    Pascaud, R S; Evans, W T; McCullagh, P J; FitzPatrick, D P

    1997-05-01

    Surface damage of the tibial plateau components of knee prostheses made from medical grade ultra-high-molecular-weight polyethylene (UHMW-PE) has been attributed to delamination wear caused by a fatigue fracture mechanism. It has been proposed that factors such as component design and method of sterilization contribute to such failure mechanisms. Understanding the fracture behaviour of UHMW-PE is therefore critical in optimizing the in vivo life-span of total joint components. The elastic-plastic fracture toughness parameter J was consequently determined for a commercial UHMW-PE at ambient and body temperatures, before and after gamma-irradiation sterilization in air at a minimum dose of 29 kGy. Both ductile stability theory and experimental data suggest that cracks propagate in a stable manner, although stability is affected by the sterilization process. Sterilization with gamma-irradiation results in a loss in fracture toughness JIc of 50% and a decrease in tearing modulus (Tm) of 30%. This dramatic reduction could result in a 50% decrease in the residual strength of the components, maximum permissible crack size under service loading and service life (assuming flaws such as fusion defects exist). The time required for a crack to grow from its original size to the maximum permissible size could be decreased by 30%, resulting in earlier failure. In terms of the design of joint replacement components the critical factor to envisage is the design stress level, which should be halved to account for the irradiation process. A scanning electron microscope study reveals that the material fails in layers parallel to the fracture surface.

  6. Pin on flat wear volume prediction of UHMWPE against cp Ti for orthopedic applications

    NASA Astrophysics Data System (ADS)

    Handoko, Suyitno, Dharmastiti, Rini; Magetsari, Rahadyan

    2018-04-01

    Tribological assessment of orthopedic biomaterials requires a lot of testing time. Researchers must test the biomaterials in millions of cycles at low frequency (1 Hz) to mimic the in vivo conditions. It is a problem because product designs and developments could not wait longer for wear data to predict the lifetime of their products. The problem can be solved with the use of computation techniques to model the wear phenomena and provide predicted data. The aim of this research is to predict the wear volume of the commonly used ultra high molecular weight polyethylene (UHMWPE) sliding against commercially pure titanium (cp Ti) in the unidirectional pin on flat tests. The 9 mm diameter UHMWPE pin and cp Ti plate contact mechanics were modeled using Abaqus. Contact pressure was set at 3 MPa. Outputs of the computations (contact pressure and contact area) were used to calculate the wear volume with Archard law. A custom Python script was made to automate the process. The results were then compared with experimental data for validations. The predicted data were in a good trend with numerical errors from 0.3% up to 26%.

  7. Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.

    PubMed

    Kane, Sheryl R; Ashby, Paul D; Pruitt, Lisa A

    2010-03-15

    A crosslinked hydrogel coating similar to poly(ethylene glycol) (PEG) was covalently bonded to the surface of ultrahigh molecular weight polyethylene (UHMWPE) to improve the lubricity and wear resistance of the UHWMPE for use in total joint replacements. The chemistry, hydrophilicity, and protein adsorption resistance of the coatings were determined, and the wear behavior of the PEG-like coating was examined by two methods: pin-on-disk tribometry to evaluate macroscale behavior, and atomic force microscopy (AFM) to simulate asperity wear. As expected, the coating was found to be highly PEG-like, with approximately 83% ether content by x-ray photoelectron spectroscopy and more hydrophilic and resistant to protein adsorption than uncoated UHMWPE. Pin-on-disk testing showed that the PEG-like coating could survive 3 MPa of contact pressure, comparable to that experienced by total hip replacements. AFM nanoscratching experiments uncovered three damage mechanisms for the coatings: adhesion/microfracture, pure adhesion, and delamination. The latter two mechanisms appear to correlate well with wear patterns induced by pin-on-disk testing and evaluated by attenuated total reflection Fourier transform infrared spectroscopy mapping. Understanding the mechanisms by which the PEG-like coatings wear is critical for improving the behavior of subsequent generations of wear-resistant hydrogel coatings. (c) 2009 Wiley Periodicals, Inc.

  8. Nondestructive characterization of UHMWPE armor materials

    NASA Astrophysics Data System (ADS)

    Chiou, Chien-Ping; Margetan, Frank J.; Barnard, Daniel J.; Hsu, David K.; Jensen, Terrence; Eisenmann, David

    2012-05-01

    Ultra-high molecular weight polyethylene (UHMWPE) is a material increasingly used for fabricating helmet and body armor. In this work, plate specimens consolidated from thin fiber sheets in series 3124 and 3130 were examined with ultrasound, X-ray and terahertz radiation. Ultrasonic through-transmission scans using both air-coupled and immersion modes revealed that the 3130 series material generally had much lower attenuation than the 3124 series, and that certain 3124 plates had extremely high attenuation. Due to the relatively low inspection frequencies used, pulse-echo immersion ultrasonic testing could not detect distinct flaw echoes from the interior. To characterize the nature of the defective condition that was responsible for the high ultrasonic attenuation, terahertz radiation in the time-domain spectroscopy mode were used to image the flaws. Terahertz scan images obtained on the high attenuation samples clearly showed a distribution of a large number of defects, possibly small planar delaminations, throughout the volume of the interior. Their precise nature and morphology are to be verified by optical microscopy of the sectioned surface.

  9. Survivorship comparison of all-polyethylene and metal-backed tibial components in cruciate-substituting total knee arthroplasty—Chinese experience

    PubMed Central

    Shen, Bin; Yang, Jing; Zhou, Zongke; Kang, Pengde; Wang, Liao

    2008-01-01

    Considering its cost saving, the all-polyethylene tibial component is of potential interest in developing countries like China. But to our knowledge, a survivorship comparison of all-polyethylene and metal-backed tibial components in posterior cruciate ligament-substituting total knee arthroplasty (PS-TKA) has not been studied in China previously. Using survivorship analysis, we have studied the midterm outcome of 34 cemented PS-TKA using an all-polyethylene tibial component and of 34 cemented PS-TKA using a metal-backed tibial component which has an identical articular surface with all-polyethylene tibial components. All operations were performed by the same group of surgeons; 58 patients underwent a unilateral operation and five patients a bilateral operation. These patients had a mean follow-up of 5.9 years (range: 5–7 years); three patients were lost to follow-up and one was revised for infection. No significant difference between the two groups was reported regarding HSS scores, ROM, clinical and radiographic parameters measured and survival rates. Although the Asian lifestyle includes more squatting and bending of the knee, the results of this series of TKA using all-polyethylene tibial components in Chinese people are comparable to the satisfactory results of other reported all-polyethylene series whose patients are mainly Western people. Considering its cost saving and excellent clinical result, the all-polyethylene tibial component is of potential interest in developing countries. PMID:18688613

  10. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs). Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements.

    PubMed

    Wright, T M; Rimnac, C M; Faris, P M; Bansal, M

    1988-10-01

    The performance of carbon fiber-reinforced ultra-high molecular weight polyethylene was compared with that of plain (non-reinforced) polyethylene on the basis of the damage that was observed on the articulating surfaces of retrieved tibial components of total knee prostheses. Established microscopy techniques for subjectively grading the presence and extent of surface damage and the histological structure of the surrounding tissues were used to evaluate twenty-six carbon fiber-reinforced and twenty plain polyethylene components that had been retrieved after an average of twenty-one months of implantation. All of the tibial components were from the same design of total knee replacement. The two groups of patients from whom the components were retrieved did not differ with regard to weight, the length of time that the component had been implanted, the radiographic position and angular alignment of the component, the original diagnosis, or the reason for removal of the component. The amounts and types of damage that were observed did not differ for the two materials. For both materials, the amount of damage was directly related to the length of time that the component had been implanted. The histological appearance of tissues from the area around the component did not differ for the two materials, except for the presence of fragments of carbon fiber in many of the samples from the areas around carbon fiber-reinforced components.

  12. Cemented all-polyethylene and metal-backed polyethylene tibial components used for primary total knee arthroplasty: a systematic review of the literature and meta-analysis of randomized controlled trials involving 1798 primary total knee implants.

    PubMed

    Voigt, Jeffrey; Mosier, Michael

    2011-10-05

    The cost of the implant as part of a total knee arthroplasty accounts for a substantial portion of the costs for the overall procedure: all-polyethylene tibial components cost considerably less than cemented metal-backed tibial components. We performed a systematic review of the literature to determine whether the clinical results of lower-cost all-polyethylene tibial components were comparable with the results of a more expensive metal-backed tibial component. We searched The Cochrane Library, MEDLINE, EMBASE, EBSCO CINAHL, the bibliographies of identified articles, orthopaedic meeting abstracts, health technology assessment web sites, and important orthopaedic journals. This search was performed for the years 1990 to the present. No language restriction was applied. We restricted our search to Level-I studies involving participants who received either an all-polyethylene or a metal-backed tibial implant. The primary outcome measures were durability, function, and adverse events. Two reviewers independently screened the papers for inclusion, assessed trial quality, and extracted data. Effects estimates were pooled with use of fixed and random-effects models of risk ratios, calculated with 95% confidence intervals. Heterogeneity was assessed with the I2 statistic. Forest plots were also generated. Data on 1798 primary total knee implants from twelve studies were analyzed. In all studies, the median or mean age of the participants was greater than sixty-seven years, with a majority of the patients being female. There was no difference between patients managed with an all-polyethylene tibial component and those managed with a metal-backed tibial component in terms of adverse events. There was no significant difference between the two groups in terms of the durability of the implants at two, ten, and fifteen years postoperatively, regardless of the year or how durability was defined (revision or radiographic failure). Finally, with use of a variety of validated

  13. Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substitute.

    PubMed

    Lowry, Michael; Rosenbaum, Heather; Walker, Peter S

    2016-05-01

    Mechanical evaluation of total knees is frequently required for aspects such as wear, strength, kinematics, contact areas, and force transmission. In order to carry out such tests, we developed a crouching simulator, based on the Oxford-type machine, with novel features including a synthetic knee including ligaments. The instrumentation and data processing methods enabled the determination of contact area locations and interface forces and moments, for a full flexion-extension cycle. To demonstrate the use of the simulator, we carried out a comparison of two different total knee designs, cruciate retaining and substituting. The first part of the study describes the simulator design and the methodology for testing the knees without requiring cadaveric knee specimens. The degrees of freedom of the anatomic hip and ankle joints were reproduced. Flexion-extension was obtained by changing quadriceps length, while variable hamstring forces were applied using springs. The knee joint was represented by three-dimensional printed blocks on to which the total knee components were fixed. Pretensioned elastomeric bands of realistic stiffnesses passed through holes in the block at anatomical locations to represent ligaments. Motion capture of the knees during flexion, together with laser scanning and computer modeling, was used to reconstruct contact areas on the bearing surfaces. A method was also developed for measuring tibial component interface forces and moments as a comparative assessment of fixation. The method involved interposing Tekscan pads at locations on the interface. Overall, the crouching machine and the methodology could be used for many different mechanical measurements of total knee designs, adapted especially for comparative or parametric studies. © IMechE 2016.

  14. Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

    PubMed

    Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario

    2016-04-01

    Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.

  15. The Mediolateral Excursion of the Meniscal Bearing during Flexion and Extension of the Knee after Medial Mobile-Bearing Unicompartmental Knee Arthroplasty.

    PubMed

    Lee, Seung-Yup; Bae, Ji-Hoon; Suh, Dong-Won; Kim, Han-Ju; Lim, Hong-Chul

    2017-02-01

    This mediolateral excursion of the bearing during knee motion is supposed to be caused by external rotation of the tibia during knee extension. However, to our knowledge, there is no published clinical evidence supporting these hypotheses. The current study aimed to evaluate the mediolateral excursion of the bearing during flexion-extension motion of the knee after medial unicompartmental knee arthroplasty (UKA). In 52 knees, varus/valgus (F-VarVal) or rotational position (F-Rot) of the femoral component and relative location of the bearing were measured with the standing anteroposterior and modified axial view, respectively. We adopted the modified axial radiographs that are simple to assess the bearing position in the flexed knee. The modified axial view showed excellent inter- and intraobserver agreements. F-Rot in the modified axial view and CT showed a high agreement in terms of validity (r = 0.98; p  < 0.0001). On average, the bearing showed more medial position in extension than flexion of the knee. No correlation was found between the femoral component positions (F-VarVal and F-Rot) and mediolateral bearing excursion ( p  = 0.68 and 0.80, respectively). In conclusion, coronal location of bearing according to flexion-extension of the knee is not influenced by the coronal and axial alignment of the femoral component. With simple radiographic method, more medial position of the bearing according to flexion-extension of the knee. Our method could be used to assess axial rotation of the femoral component and spin-out phenomenon of the bearing following the medial UKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Total knee arthroplasty for severe valgus knee deformity.

    PubMed

    Zhou, Xinhua; Wang, Min; Liu, Chao; Zhang, Liang; Zhou, Yixin

    2014-01-01

    rivaroxaban and thrombo-embolic deterrent stockings. There was no incidence of pulmonary embolism. Post-operative patient satisfaction was 80.7 ± 10.4 points in the groups. Prosthetic survival rate was 100% at mean 10 years postoperative. Not only hinged implants can be successfully used in variant-III valgus knees. As our results show, if proper ligament balancing techniques are used and proper ligament balance is attained, the knee may not require the use of a more constrained components. Our results also present alternative implant choices for severe knee deformities.

  17. Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty.

    PubMed

    Arnholt, Christina M; MacDonald, Daniel W; Malkani, Arthur L; Klein, Gregg R; Rimnac, Clare M; Kurtz, Steven M; Kocagoz, Sevi B; Gilbert, Jeremy L

    2016-12-01

    Metal debris and ion release has raised concerns in joint arthroplasty. The purpose of this study was to characterize the sources of metallic ions and particulate debris released from long-term (in vivo >15 years) total knee arthroplasty femoral components. A total of 52 CoCr femoral condyles were identified as having been implanted for more than 15 years. The femoral components were examined for incidence of 5 types of damage (metal-on-metal wear due to historical polyethylene insert failure, mechanically assisted crevice corrosion at taper interfaces, cement interface corrosion, third-body abrasive wear, and inflammatory cell-induced corrosion [ICIC]). Third-body abrasive wear was evaluated using the Hood method for polyethylene components and a similar method quantifying surface damage of the femoral condyle was used. The total area damaged by ICIC was quantified using digital photogrammetry. Surface damage associated with corrosion and/or CoCr debris release was identified in 51 (98%) CoCr femoral components. Five types of damage were identified: 98% of femoral components exhibited third-body abrasive wear (mostly observed as scratching, n = 51/52), 29% of femoral components exhibited ICIC damage (n = 15/52), 41% exhibited cement interface damage (n = 11/27), 17% exhibited metal-on-metal wear after wear-through of the polyethylene insert (n = 9/52), and 50% of the modular femoral components exhibited mechanically assisted crevice corrosion taper damage (n = 2/4). The total ICIC-damaged area was an average of 0.11 ± 0.12 mm 2 (range: 0.01-0.46 mm 2 ). Although implant damage in total knee arthroplasty is typically reported with regard to the polyethylene insert, the results of this study demonstrate that abrasive and corrosive damage occurs on the CoCr femoral condyle in vivo. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Failure of aseptic revision total knee arthroplasties

    PubMed Central

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-01-01

    Background and purpose In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. Method This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. Results 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). Interpretation In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties. PMID:25267502

  19. MR Imaging of Knee Arthroplasty Implants

    PubMed Central

    Fritz, Jan; Lurie, Brett

    2015-01-01

    Primary total knee arthroplasty is a highly effective treatment that relieves pain and improves joint function in a large percentage of patients. Despite an initially satisfactory surgical outcome, pain, dysfunction, and implant failure can occur over time. Identifying the etiology of complications is vital for appropriate management and proper timing of revision. Due to the increasing number of knee arthroplasties performed and decreasing patient age at implantation, there is a demand for accurate diagnosis to determine appropriate treatment of symptomatic joints following knee arthroplasty, and for monitoring of patients at risk. Magnetic resonance (MR) imaging allows for comprehensive imaging evaluation of the tissues surrounding knee arthroplasty implants with metallic components, including the polyethylene components. Optimized conventional and advanced pulse sequences can result in substantial metallic artifact reduction and afford improved visualization of bone, implant-tissue interfaces, and periprosthetic soft tissue for the diagnosis of arthroplasty-related complications. In this review article, we discuss strategies for MR imaging around knee arthroplasty implants and illustrate the imaging appearances of common modes of failure, including aseptic loosening, polyethylene wear–induced synovitis and osteolysis, periprosthetic joint infections, fracture, patellar clunk syndrome, recurrent hemarthrosis, arthrofibrosis, component malalignment, extensor mechanism injury, and instability. A systematic approach is provided for evaluation of MR imaging of knee implants. MR imaging with optimized conventional pulse sequences and advanced metal artifact reduction techniques can contribute important information for diagnosis, prognosis, risk stratification, and surgical planning. ©RSNA, 2015 PMID:26295591

  20. Imageless navigation system does not improve component rotational alignment in total knee arthroplasty.

    PubMed

    Cheng, Tao; Zhang, Guoyou; Zhang, Xianlong

    2011-12-01

    The aim of computer-assisted surgery is to improve accuracy and limit the range of surgical variability. However, a worldwide debate exists regarding the importance and usefulness of computer-assisted navigation for total knee arthroplasty (TKA). The main purpose of this study is to summarize and compare the radiographic outcomes of TKA performed using imageless computer-assisted navigation compared with conventional techniques. An electronic search of PubMed, EMBASE, Web of Science, and Cochrane library databases was made, in addition to manual search of major orthopedic journals. A meta-analysis of 29 quasi-randomized/randomized controlled trials (quasi-RCTs/RCTs) and 11 prospective comparative studies was conducted through a random effects model. Additional a priori sources of clinical heterogeneity were evaluated by subgroup analysis with regard to radiographic methods. When the outlier cut-off value of lower limb axis was defined as ±2° or ±3° from the neutral, the postoperative full-length radiographs demonstrated that the risk ratio was 0.54 or 0.39, respectively, which were in favor of the navigated group. When the cut-off value used for the alignment in the coronal and sagittal plane was 2° or 3°, imageless navigation significantly reduced the outlier rate of the femoral and tibial components compared with the conventional group. Notably, computed tomography scans demonstrated no statistically significant differences between the two groups regarding the outliers in the rotational alignment of the femoral and tibial components; however, there was strong statistical heterogeneity. Our results indicated that imageless computer-assisted navigation systems improve lower limb axis and component orientation in the coronal and sagittal planes, but not the rotational alignment in TKA. Further multiple-center clinical trials with long-term follow-up are needed to determine differences in the clinical and functional outcomes of knee arthroplasties performed

  1. Higher Rate of Revision in PFC Sigma Primary Total Knee Arthroplasty With Mismatch of Femoro-Tibial Component Sizes.

    PubMed

    Young, Simon W; Clarke, Henry D; Graves, Stephen E; Liu, Yen-Liang; de Steiger, Richard N

    2015-05-01

    Total knee arthroplasty (TKA) systems permit a degree of femoro-tibial component size mismatch. The effect of mismatched components on revision rates has not been evaluated in a large study. We reviewed 21,906 fixed-bearing PFC Sigma primary TKAs using the Australian Orthopaedic Association National Joint Replacement Registry, dividing patients into three groups: no femoro-tibial size mismatch, tibial component size > femoral component size, and femoral component > tibial component. Revision rates were higher when the femoral size was greater than the tibia, compared to both equal size (HR = 1.20 (1.00, 1.45), P = 0.047) and to tibial size greater than femoral (HR = 1.60 (1.08, 2.37), P = 0.019). Potential mechanisms to explain these findings include edge loading of polyethylene and increased tibial component stresses. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Lateral unicompartmental knee replacement: fixed or mobile bearing?

    PubMed

    Forster, M C; Bauze, A J; Keene, G C R

    2007-09-01

    Between May 2001 and May 2003, 233 consecutive Preservation unicompartmental knee replacements (UKR) were performed. Of these, 30 were lateral UKRs (13%) performed in 12 men and 16 women (2 bilateral cases) with a mean age of 67 years (range 36-93 years). A metal-backed mobile bearing tibial component was used in 13 knees and an all-polyethylene fixed bearing tibial component in 17 knees. The patients were reviewed prospectively at 1 and 2 years. The 2 year results show no difference in range of motion or function between the mobile and fixed bearing versions of the Preservation knee when used on the lateral side. There were three early revisions, all in the mobile bearing group.

  3. Existence of a neuropathic pain component in patients with osteoarthritis of the knee.

    PubMed

    Ohtori, Seiji; Orita, Sumihisa; Yamashita, Masaomi; Ishikawa, Tetsuhiro; Ito, Toshinori; Shigemura, Tomonori; Nishiyama, Hideki; Konno, Shin; Ohta, Hideyuki; Takaso, Masashi; Inoue, Gen; Eguchi, Yawara; Ochiai, Nobuyasu; Kishida, Shunji; Kuniyoshi, Kazuki; Aoki, Yasuchika; Arai, Gen; Miyagi, Masayuki; Kamoda, Hiroto; Suzkuki, Miyako; Nakamura, Junichi; Furuya, Takeo; Kubota, Gou; Sakuma, Yoshihiro; Oikawa, Yasuhiro; Suzuki, Masahiko; Sasho, Takahisa; Nakagawa, Koichi; Toyone, Tomoaki; Takahashi, Kazuhisa

    2012-07-01

    Pain from osteoarthritis (OA) is generally classified as nociceptive (inflammatory). Animal models of knee OA have shown that sensory nerve fibers innervating the knee are significantly damaged with destruction of subchondral bone junction, and induce neuropathic pain (NP). Our objective was to examine NP in the knees of OA patients using painDETECT (an NP questionnaire) and to evaluate the relationship between NP, pain intensity, and stage of OA. Ninety-two knee OA patients were evaluated in this study. Pain scores using Visual Analogue Scales (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), painDETECT, duration of symptoms, severity of OA using the Kellgren-Lawrence (KL) system, and amount of joint fluid were evaluated and compared using a Spearman's correlation coefficient by rank test. Our study identified at least 5.4% of our knee OA patients as likely to have NP and 15.2% as possibly having NP. The painDETECT score was significantly correlated with the VAS and WOMAC pain severity. Compared with the painDETECT score, there was a tendency for positive correlation with the KL grade, and tendency for negative correlation with the existence and amount of joint fluid, but these correlations were not significant. PainDETECT scores classified 5.4% of pain from knee OA as NP. NP tended to be seen in patients with less joint fluid and increased KL grade, both of which corresponded to late stages of OA. It is important to consider the existence of NP in the treatment of knee OA pain.

  4. Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium.

    PubMed

    Brandt, J-M; Guenther, L; O'Brien, S; Vecherya, A; Turgeon, T R; Bohm, E R

    2013-12-01

    The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. Level IV. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  5. Body mass index affects knee joint mechanics during gait differently with and without moderate knee osteoarthritis.

    PubMed

    Harding, Graeme T; Hubley-Kozey, Cheryl L; Dunbar, Michael J; Stanish, William D; Astephen Wilson, Janie L

    2012-11-01

    Obesity is a highly cited risk factor for knee osteoarthritis (OA), but its role in knee OA pathogenesis and progression is not as clear. Excess weight may contribute to an increased mechanical burden and altered dynamic movement and loading patterns at the knee. The objective of this study was to examine the interacting role of moderate knee OA disease presence and obesity on knee joint mechanics during gait. Gait analysis was performed on 104 asymptomatic and 140 individuals with moderate knee OA. Each subject group was divided into three body mass categories based on body mass index (BMI): healthy weight (BMI<25), overweight (25≤BMI≤30), and obese (BMI>30). Three-dimensional knee joint angles and net external knee joint moments were calculated and waveform principal component analysis (PCA) was applied to extract major patterns of variability from each. PC scores for major patterns were compared between groups using a two-factor ANOVA. Significant BMI main effects were found in the pattern of the knee adduction moment, the knee flexion moment, and the knee rotation moment during gait. Two interaction effects between moderate OA disease presence and BMI were also found that described different changes in the knee flexion moment and the knee flexion angle with increased BMI with and without knee OA. Our results suggest that increased BMI is associated with different changes in biomechanical patterns of the knee joint during gait depending on the presence of moderate knee OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  6. Optimizing thickness of ceramic coatings on plastic components for orthopedic applications: A finite element analysis.

    PubMed

    Marchiori, G; Lopomo, N; Boi, M; Berni, M; Bianchi, M; Gambardella, A; Visani, A; Russo, A; Marcacci, M

    2016-01-01

    Realizing hard ceramic coatings on the plastic component of a joint prosthesis can be strategic for the mechanical preservation of the whole implant and to extend its lifetime. Recently, thanks to the Plasma Pulsed Deposition (PPD) method, zirconia coatings on ultra-high molecular weight polyethylene (UHMWPE) substrates resulted in a feasible outcome. Focusing on both the highly specific requirements defined by the biomedical application and the effective possibilities given by the deposition method in the perspectives of technological transfer, it is mandatory to optimize the coating in terms of load bearing capacity. The main goal of this study was to identify through Finite Element Analysis (FEA) the optimal coating thickness that would be able to minimize UHMWPE strain, possible insurgence of cracks within the coating and stresses at coating-substrate interface. Simulations of nanoindentation and microindentation tests were specifically carried out. FEA findings demonstrated that, in general, thickening the zirconia coating strongly reduced the strains in the UHMWPE substrate, although the 1 μm thickness value was identified as critical for the presence of high stresses within the coating and at the interface with the substrate. Therefore, the optimal thickness resulted to be highly dependent on the specific loading condition and final applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Inducible displacement of cemented tibial components ten years after total knee arthroplasty.

    PubMed

    Lam Tin Cheung, K; Lanting, B A; McCalden, R W; Yuan, X; MacDonald, S J; Naudie, D D; Teeter, M G

    2018-02-01

    The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA). A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation). All patients showed some inducible displacement. Two patients with radiolucent lines had greater mean standing-supine MTPM displacement (1.35; sd 0.38) compared with the remaining patients (0.68; sd 0.36). These two patients also had a greater mean longitudinal MTPM at ten years (0.64; sd 0.50) compared with the remaining patients (0.39; sd 0.13 mm). Small inducible displacements in well-fixed cemented tibial components were seen ten years postoperatively, of a similar magnitude to that which has been reported for well-fixed components one to two years postoperatively. Greater displacements were found in components with radiolucent lines. Cite this article: Bone Joint J 2018;100-B:170-5. ©2018 The British Editorial Society of Bone & Joint Surgery.

  8. A myofascial component of pain in knee osteoarthritis.

    PubMed

    Dor, Adi; Kalichman, Leonid

    2017-07-01

    Osteoarthritis (OA) is the most common cause of musculoskeletal pain and disability. The knee is the most common site of OA. Numerous studies have shown an inconsistency between patients' reports of pain and their radiographic findings. This inconsistency may be partially explained by the fact that a portion of the pain originates from the myofascial trigger points (MTrPs) located in the surrounding muscles. To assess the role of myofascial pain in OA patients. Critical review. PubMed, Google Scholar, Scopus, and PEDro databases were searched from inception until December 2016 for the following keywords: "myofascial pain", "osteoarthritis", "trigger points", "knee" or any combination of these words. The reference lists of all articles retrieved were searched as well. The current review included two observational studies evaluating the prevalence of MTrPs in OA patients and six interventional studies describing the treatment of myofascial pain in OA patients. Data from two of the interventional studies also included an observational section. The reviewed observational studies offered initial evidence as to the assumption that myofascial pain and the presence of MTrPs may play a role in pain and disability of knee OA. Because of the cross-sectional design of these studies, the causal relationships could not be established. Additional studies are needed to confirm this assumption as well as to clarify if MTrPs are a portion of OA etiology or that OA is the basis for MTrPs formation. Each interventional study elaborated on various myofascial treatment techniques. However, treatment focusing on MTrPs seems to be effective in reducing pain and improving function in OA patients. Due to the heterogeneity in treatment methods and outcome measures, it is difficult to attain a definite conclusion and therefore, additional high-quality randomized controlled trials are warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Total knee replacement-cementless tibial fixation with screws: 10-year results.

    PubMed

    Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım

    2017-12-01

    The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  10. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.

    PubMed

    de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico

    2017-11-01

    Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Validated Measures of Illness Perception and Behavior in People with Knee Pain and Knee Osteoarthritis: A Scoping Review.

    PubMed

    Hamilton, Clayon B; Wong, Ming-Kin; Gignac, Monique A M; Davis, Aileen M; Chesworth, Bert M

    2017-01-01

    To identify validated measures that capture illness perception and behavior and have been used to assess people who have knee pain/osteoarthritis. A scoping review was performed. Nine electronic databases were searched for records from inception through April 19, 2015. Search terms included illness perception, illness behavior, knee, pain, osteoarthritis, and their related terms. This review included English language publications of primary data on people with knee pain/osteoarthritis who were assessed with validated measures capturing any of 4 components of illness perception and behavior: monitor body, define and interpret symptoms, take remedial action, and utilize sources of help. Seventy-one publications included relevant measures. Two reviewers independently coded and analyzed each relevant measure within the 4 components. Sixteen measures were identified that capture components of illness perception and behavior in the target population. These measures were originally developed to capture constructs that include coping strategies/skills/styles, illness belief, illness perception, self-efficacy, and pain behavior. Coding results indicated that 5, 11, 12, and 5 of these measures included the monitor body, define and interpret symptoms, take remedial action, and utilize sources of help components, respectively. Several validated measures were interpreted as capturing some components, and only 1 measure was interpreted as capturing all of the components of illness perception and behavior in the target population. A measure that comprehensively captures illness perception and behavior could be valuable for informing and evaluating therapy for patients along a continuum of symptomatic knee osteoarthritis. © 2016 World Institute of Pain.

  12. Cyclic steady state stress-strain behavior of UHMW polyethylene.

    PubMed

    Krzypow, D J; Rimnac, C M

    2000-10-01

    To increase the long-term performance of total joint replacements, finite element analyses of ultra high molecular weight polyethylene (UHMWPE) components have been conducted to predict the effect of load on the stress and strain distributions occurring on and within these components. Early models incorporated the monotonic behavior of UHMWPE without considering the unloading and cyclic loading behavior. However, UHMWPE components undergo cyclic loading during use and at least two wear damage modes (pitting and delamination) are thought to be associated with the fatigue fracture properties of UHMWPE. The objective of this study was to examine the fully reversed uniaxial tension/compression cyclic steady state stress-strain behavior of UHMWPE as a first step towards developing a cyclic constitutive relationship for UHMWPE. The hypothesis that cycling results in a permanent change in the stress-strain relationship, that is, that the cyclic steady state represents a new cyclically stabilized state, was examined. It was found that, like other ductile polymers, UHMWPE substantially cyclically softens under fully reversed uniaxial straining. More cyclic softening occurred in tension than in compression. Furthermore, cyclic steady state was attained, but not cyclic stability. It is suggested that it may be more appropriate to base a material constitutive relationship for UHMWPE for finite element analyses of components upon a cyclically modified stress-strain relationship.

  13. The Effects of the Inertial Properties of Above-Knee Prostheses on Optimal Stiffness, Damping, and Engagement Parameters of Passive Prosthetic Knees.

    PubMed

    Narang, Yashraj S; Murthy Arelekatti, V N; Winter, Amos G

    2016-12-01

    Our research aims to design low-cost, high-performance, passive prosthetic knees for developing countries. In this study, we determine optimal stiffness, damping, and engagement parameters for a low-cost, passive prosthetic knee that consists of simple mechanical elements and may enable users to walk with the normative kinematics of able-bodied humans. Knee joint power was analyzed to divide gait into energy-based phases and select mechanical components for each phase. The behavior of each component was described with a polynomial function, and the coefficients and polynomial order of each function were optimized to reproduce the knee moments required for normative kinematics of able-bodied humans. Sensitivity of coefficients to prosthesis mass was also investigated. The knee moments required for prosthesis users to walk with able-bodied normative kinematics were accurately reproduced with a mechanical system consisting of a linear spring, two constant-friction dampers, and three clutches (R2=0.90 for a typical prosthetic leg). Alterations in upper leg, lower leg, and foot mass had a large influence on optimal coefficients, changing damping coefficients by up to 180%. Critical results are reported through parametric illustrations that can be used by designers of prostheses to select optimal components for a prosthetic knee based on the inertial properties of the amputee and his or her prosthetic leg.

  14. Effect of rotational alignment on outcome of total knee arthroplasty

    PubMed Central

    Breugem, Stefan J; van den Bekerom, Michel PJ; Tuinebreijer, Willem E; van Geenen, Rutger C I

    2015-01-01

    Background and purpose Poor outcomes have been linked to errors in rotational alignment of total knee arthroplasty components. The aims of this study were to determine the correlation between rotational alignment and outcome, to review the success of revision for malrotated total knee arthroplasty, and to determine whether evidence-based guidelines for malrotated total knee arthroplasty can be proposed. Patients and methods We conducted a systematic review including all studies reporting on both rotational alignment and functional outcome. Comparable studies were used in a correlation analysis and results of revision were analyzed separately. Results 846 studies were identified, 25 of which met the inclusion criteria. From this selection, 11 studies could be included in the correlation analysis. A medium positive correlation (ρ = 0.44, 95% CI: 0.27–0.59) and a large positive correlation (ρ = 0.68, 95% CI: 0.64–0.73) were found between external rotation of the tibial component and the femoral component, respectively, and the Knee Society score. Revision for malrotation gave positive results in all 6 studies in this field. Interpretation Medium and large positive correlations were found between tibial and femoral component rotational alignment on the one hand and better functional outcome on the other. Revision of malrotated total knee arthroplasty may be successful. However, a clear cutoff point for revision for malrotated total knee arthroplasty components could not be identified. PMID:25708694

  15. Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    PubMed

    Jones, V C; Barton, D C; Auger, D D; Hardaker, C; Stone, M H; Fisher, J

    2001-01-01

    A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion at the tibial counterfaces of unconstrained mobile bearing knees. The average +/- STERR wear rates were 13.78+/-1.06 mm3/Mcycles for the ADLC counterfaces and 0.504+/-0.12 mm3/Mcycles for the control CoCr counterfaces. All of the pins run on the ADLC counterfaces exhibited the same patterns of blistering along the central axis, and severe abrasion elsewhere to the extent that all of the original machining marks were removed after just one week of testing. The average value of friction coefficient was 0.24 for the ADLC counterfaces and 0.073 for the control CoCr counterfaces. The factor of 3.5 increase was statistically significant at p < 0.05. In the tribological evaluation of ADLC coatings for tibial trays in mobile bearing knees, this study shows that this specific Physical Vapour Deposition (PVD) ADLC showed significantly poorer frictional and wear performance than uncoated surfaces which was sufficient to negate any potential benefits of improved resistance to third body damage.

  16. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metallic constrained... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint... knee joint. The device prevents dislocation in more than one anatomic plane and has components that are...

  17. Total knee arthroplasty following prior distal femoral fracture.

    PubMed

    Papadopoulos, Elias C; Parvizi, Javad; Lai, Choon H; Lewallen, David G

    2002-12-01

    Femoral fracture may predispose the knee to the development of post-traumatic arthritis by either a direct intra-articular injury or residual limb malalignment. Malunion, intra-articular osseous defects, limb malalignment, retained internal fixation devices, and compromised surrounding soft tissues may in turn affect the outcome of total knee arthroplasty (TKA) in these patients. The aim of our study was to evaluate the result of TKA in patients with previous distal femoral fracture. The results of 48 cemented condylar total knee arthroplasties, performed between 1980 to 1998, in 47 patients with a previous distal femoral fracture were reviewed. There were 37 females and 10 males with an average age of 65 years (range, 19-84 years). Follow-up averaged 6.2 years (range, 2-16 years). No patients were lost to follow-up. At the time of arthroplasty a femoral fracture non-union was present in three knees, all of which were treated with a long stem cemented femoral component and bone grafting. Malunion, defined as angulation greater than 10 degrees in the coronal plain or greater than 15 degrees in the sagittal plain, was present in 21 knees. Of these, six underwent distal femoral osteotomy during TKA. In the remaining 15 patients, with a malunion, the deformity was addressed by alterations in the orientation and location of bone resection. Other procedures were commonly needed at the time of arthroplasty and included: lateral retinacular release (22 knees), extensor mechanism realignment (eight knees), and collateral ligament reconstruction (two knees). The mean pre-operative Knee Society Scores were 40 (range, 0-80) for pain and 48 (range, 0-100) for function and improved significantly to a mean of 84 (range, 37-99) and 66 (range, 0-100) points, respectively, at the latest follow-up (P<0.001). The knee arc of motion improved from a pre-operative mean of 83-99 degrees at the latest follow-up (P<0.004). Post-operative manipulation under anesthesia for poor motion was

  18. The anterior trochlear line as a reference for femoral component positioning in total knee arthroplasty.

    PubMed

    Morizane, Kazuki; Takahashi, Toshiaki; Konishi, Fumihiko; Yamamoto, Haruyasu

    2011-12-01

    A new radiographic method using the anterior and posterior femoral condyles as a landmark to determine the rotational alignment of the femoral component in TKA had been developed. The new radiograph presents an axial view of the distal femur. The patients were asked to lie in the supine position and flex the knee approximately 120° to 130°. Radiographs were applied at an inclination angle of 20° to 30°. The condylar twist angle (CTA), the external rotational angle between the posterior condylar (PC) line and the clinical transepicondylar axis (TEA), and the trochlear line angle (TLA), and the internal rotational angle between the anterior trochlear line and the clinical TEA were measured. Images were taken of 129 knees in 87 patients with osteoarthritis of the knee. The measurement values obtained using our method with those obtained using 3D reconstructed images from a 3-dimensional helical CT system (n = 35) were compared. The average CTA was 5.7° ± 2.8° and the average TLA was -5.6° ± 3.2°. The CTA was negatively correlated with the tibiofemoral angle (TFA). The average TLA was positively correlated with the TFA. The average difference between the TLA values obtained with this view and those obtained using the 3D-CT was 0.5° ± 1.6°. The relationship between the radiograph and 3D-CT in TLA was higher than that in CTA. This radiographic technique allows easy and simultaneous measurement of the CTA and TLA and may provide an alternative method for assessing the TEA of the femur during preoperative planning for TKA.

  19. Vibration arthrometry in the patients with failed total knee replacement.

    PubMed

    Jiang, C C; Lee, J H; Yuan, T T

    2000-02-01

    This is a preliminary research on the vibration arthrometry of artificial knee joint in vivo. Analyzing the vibration signals measured from the accelerometer on patella, there are two speed protocols in knee kinematics: 1) 2 degrees/s, the signal is called "physiological patellofemoral crepitus (PPC)", and 2) 67 degrees/s, the signal is called "vibration signal in rapid knee motion". The study has collected 14 patients who had revision total knee arthroplasty due to prosthetic wear or malalignment represent the failed total knee replacement (FTKR), and 12 patients who had just undergone the primary total knee arthroplasty in the past two to six months and have currently no knee pain represent the normal total knee replacement (NTKR). FTKR is clinically divided into three categories: metal wear, polyethylene wear of the patellar component, and no wear but with prosthesis malalignment. In PPC, the value of root mean square (rms) is used as a parameter; in vibration signals in rapid knee motion, autoregressive modeling is used for adaptive segmentation and extracting the dominant pole of each signal segment to calculate the spectral power ratios in f < 100 Hz and f > 500 Hz. It was found that in the case of metal wear, the rms value of PPC signal is far greater than a knee joint with polyethylene wear and without wear, i.e., PPC signal appears only in metal wear. As for vibration signals in rapid knee motion, prominent time-domain vibration signals could be found in the FTKR patients with either polyethylene or metal wear of the patellar component. We also found that for normal knee joint, the spectral power ratio of dominant poles has nearly 80% distribution in f < 100 Hz, is between 50% and 70% for knee with polyethylene wear and below 30% for metal wear, whereas in f > 500 Hz, spectral power ratio of dominant poles has over 30% distribution in metal wear but only nonsignificant distribution in polyethylene wear, no wear, and normal knee. The results show that

  20. A new rabbit model of implant-related biofilm infection: development and evaluation

    NASA Astrophysics Data System (ADS)

    Chu, Cheng-Bing; Zeng, Hong; Shen, Ding-Xia; Wang, Hui; Wang, Ji-Fang; Cui, Fu-Zhai

    2016-03-01

    This study is to establish a rabbit model for human prosthetic joint infection and biofilm formation. Thirty-two healthy adult rabbits were randomly divided into four groups and implanted with stainless steel screws and ultra-high molecular weight polyethylene (UHMWPE) washers in the non-articular surface of the femoral lateral condyle of the right hind knees. The rabbit knee joints were inoculated with 1 mL saline containing 0, 102, 103, 104 CFU of Staphylococcus epidermidis ( S. epidermidis) isolated from the patient with total knee arthroplasty (TKA) infection, respectively. On the 14th postoperative day, the UHMWPE washers from the optimal 103 CFU group were further examined. The SEM examination showed a typical biofilm construction that circular S. epidermidis were embedded in a mucous-like matrix. In addition, the LCSM examination showed that the biofilm consisted of the polysaccharide stained bright green fluorescence and S. epidermidis radiating red fluorescence. Thus, we successfully create a rabbit model for prosthetic joint infection and biofilm formation, which should be valuable for biofilm studies.

  1. Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE.

    PubMed

    Cole, Jantzen C; Lemons, Jack E; Eberhardt, Alan W

    2002-01-01

    Pitting and delamination remain causative factors of polyethylene failure in total knee replacement. Gamma irradiation induces cross linking in ultra-high-molecular-weight polyethylene, which has been shown to improve wear resistance. Irradiation may reduce fracture toughness and fatigue strength, however, and the effects of irradiation are dependent upon the resin, processing technique, and radiation dose. The effects of varying levels of gamma irradiation (0, 33, 66, and 100 kGy) on the fracture toughness and fatigue-crack resistance of UHMWPE, isostatically molded from 1900H and GUR 1050 resins, were examined. Paris law regressions were performed to quantify fatigue-crack propagation rates as functions of change in stress intensity, and J-integral methods were used to quantify the elastic-plastic fracture toughness. The results indicated that gamma irradiation reduced the resistance of both materials to fatigue-crack growth, and that the reductions were radiation dosage and resin dependent. Irradiation at any level was detrimental to the fracture toughness of the 1900H specimens. Irradiation at 33 kGy increased fracture toughness for the GUR 1050 specimens, and substantial reductions were observed only at the highest irradiation level. Scanning electron microscopy of the fracture surface revealed diamond-like fracture patterns of the nonirradiated specimens indicative of ductile, multilevel fracture. Pronounced striations were apparent on these fracture surfaces, oriented perpendicular to the direction of crack growth. The striations appeared as folds in surface layers of the GUR 1050 specimens. At the highest irradiation levels, the striations were nearly eliminated on the fracture surfaces of the 1900H specimens, and were markedly less severe for the GUR 1050. These results demonstrated that at higher irradiation levels the materials became more brittle in fatigue, with less ductile folding and tearing of the fracture surfaces. Copyright 2002 Wiley Periodicals

  2. Comparison of cemented and uncemented fixation in total knee arthroplasty.

    PubMed

    Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian

    2013-05-01

    As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.

  3. Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials.

    PubMed

    Bian, Yan-Yan; Zhou, Lei; Zhou, Gang; Jin, Zhong-Min; Xin, Shi-Xuan; Hua, Zi-Kai; Weng, Xi-Sheng

    2018-06-01

    Ultra-low-wear polyethylene (ULWPE) is a new type polyethylene made by experts who are from China petrochemical research institute, which is easy to process and implant. Preliminary test showed it was more resistant to wear than that of Ultra-high-molecular weight polyethylene (UHMWPE). The purpose of the research is to study biocompatibility, bio-tribological properties and debris characterization of ULWPE. Cytotoxicity test, hemolysis test, acute/chronic toxicity and muscular implantation test were conducted according to national standard GB/T-16886/ISO-10993 for evaluation requirements of medical surgical implants. We obtained that this novel material had good biocompatibility and biological safety. The wear performance of ULWPE and UHMWPE was evaluated in a pin-on-disc (POD) wear tester within two million cycles and a knee wear simulator within six million cycles. We found that the ULWPE was higher abrasion resistance than the UHMWPE, the wear rate of ULWPE by POD test and knee wear simulator was 0.4 mg/10 6 cycles and (16.9 ± 1.8)mg/10 6 cycles respectively, while that of UHMWPE was 1.8 mg/10 6 cycles and (24.6 ± 2.4)mg/10 6 cycles. The morphology of wear debris is also an important factor to evaluate artificial joint materials, this study showed that the ULWPE wear debris gotten from the simulator had various different shapes, including spherical, block, tear, etc. The morphology of worn surface and wear debris analysis showed that wear mechanisms of ULWPE were adhesion wear, abrasive wear and fatigue wear and other wear forms, which were consistent with that of UHMWPE. Thus we conclude that ULWPE is expected to be a lifetime implantation of artificial joint. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. High accuracy in knee alignment and implant placement in unicompartmental medial knee replacement when using patient-specific instrumentation.

    PubMed

    Volpi, P; Prospero, E; Bait, C; Cervellin, M; Quaglia, A; Redaelli, A; Denti, M

    2015-05-01

    The influence of patient-specific instrumentations on the accuracy of unicompartmental medial knee replacement remains unclear. The goal of this study was to examine the ability of patient-specific instrumentation to accurately reproduce postoperatively what the surgeon had planned preoperatively. Twenty consecutive patients (20 knees) who suffered from isolated unicompartmental medial osteoarthritis of the knee and underwent medial knee replacement using newly introduced magnetic resonance imaging-based patient-specific instrumentation were assessed. This assessment recorded the following parameters: (1) the planned and the postoperative mechanical axis acquired through long-leg AP view radiographies; (2) the planned and the postoperative tibial slope acquired by means of standard AP and lateral view radiographies; and (3) the postoperative fit of the implanted components to the bone in coronal and sagittal planes. The hypothesis of the study was that there was no statistically significant difference between postoperative results and preoperatively planned values. The study showed that (1) the difference between the postoperative mechanical axis (mean 1.9° varus ± 1.2° SD) and the planned mechanical axis (mean 1.8° varus ± 1.2° SD) was not statistically significant; (2) the difference between the postoperative tibial slope (mean 5.2° ± 0.6° SD) and the planned tibial slope (mean 5.4° ± 0.6° SD) was statistically significant (p = 0.008); and (3) the postoperative component fit to bone in the coronal and sagittal planes was accurate in all cases; nevertheless, in one knee, all components were implanted one size smaller than preoperatively planned. Moreover, in two additional cases, one size thinner and one size thicker of the polyethylene insert were used. This study suggests that overall patient-specific instrumentation was highly accurate in reproducing postoperatively what the surgeon had planned preoperatively in terms of mechanical axis, tibial

  5. Total knee arthroplasty after high tibial osteotomy. A comparison study in patients who had bilateral total knee replacement.

    PubMed

    Meding, J B; Keating, E M; Ritter, M A; Faris, P M

    2000-09-01

    not found to be significant with the numbers available (p = 0.4810). Knee alignment and stability, femoral and tibial component alignment, and range of motion also were similar in both groups postoperatively. One allpolyethylene tibial component was revised in the high tibial osteotomy group. Two knees in each group required manipulation. There were no deep infections. While patients with a previous high tibial osteotomy may have important differences preoperatively, including valgus alignment, patella infera, and decreased bone stock in the proximal part of the tibia, the present study suggests that the clinical and radiographic results of primary total knee arthroplasty in knees with and without a previous high tibial osteotomy are not substantially different. In our relatively small group of patients, the previous high tibial osteotomy had no adverse effect on the outcome of the subsequent total knee replacement.

  6. The Complexity of Human Walking: A Knee Osteoarthritis Study

    PubMed Central

    Kotti, Margarita; Duffell, Lynsey D.; Faisal, Aldo A.; McGregor, Alison H.

    2014-01-01

    This study proposes a framework for deconstructing complex walking patterns to create a simple principal component space before checking whether the projection to this space is suitable for identifying changes from the normality. We focus on knee osteoarthritis, the most common knee joint disease and the second leading cause of disability. Knee osteoarthritis affects over 250 million people worldwide. The motivation for projecting the highly dimensional movements to a lower dimensional and simpler space is our belief that motor behaviour can be understood by identifying a simplicity via projection to a low principal component space, which may reflect upon the underlying mechanism. To study this, we recruited 180 subjects, 47 of which reported that they had knee osteoarthritis. They were asked to walk several times along a walkway equipped with two force plates that capture their ground reaction forces along 3 axes, namely vertical, anterior-posterior, and medio-lateral, at 1000 Hz. Data when the subject does not clearly strike the force plate were excluded, leaving 1–3 gait cycles per subject. To examine the complexity of human walking, we applied dimensionality reduction via Probabilistic Principal Component Analysis. The first principal component explains 34% of the variance in the data, whereas over 80% of the variance is explained by 8 principal components or more. This proves the complexity of the underlying structure of the ground reaction forces. To examine if our musculoskeletal system generates movements that are distinguishable between normal and pathological subjects in a low dimensional principal component space, we applied a Bayes classifier. For the tested cross-validated, subject-independent experimental protocol, the classification accuracy equals 82.62%. Also, a novel complexity measure is proposed, which can be used as an objective index to facilitate clinical decision making. This measure proves that knee osteoarthritis subjects exhibit more

  7. Finite element analysis of unicompartmental knee arthroplasty.

    PubMed

    Hopkins, Andrew R; New, Andrew M; Rodriguez-y-Baena, Ferdinando; Taylor, Mark

    2010-01-01

    Concerns over accelerated damage to the untreated compartment of the knee following unicompartmental knee arthroplasty (UKA), as well as the relatively poor success rates observed for lateral as opposed to the medial arthroplasty, remain issues for attention. Finite element analysis (FEA) was used to assess changes to the kinematics and potential for cartilage damage across the knee joint in response to the implantation of the Oxford Mobile Bearing UKA. FE models of lateral and medial compartment arthroplasty were developed, in addition to a healthy natural knee model, to gauge changes incurred through the arthroplasty. Varus-valgus misalignments were introduced to the femoral components to simulate surgical inaccuracy or over-correction. Boundary conditions from the Stanmore knee simulator during the stance phase of level gait were used. AP translations of the tibia in the medial UKA models were comparable to the behaviour of the natural knee models (+/-0.6mm deviation from pre-operative motion). Following lateral UKA, 4.1mm additional posterior translation of the tibia was recorded than predicted for the natural knee. IE rotations of the medial UKA models were less consistent with the pre-operative knee model than the lateral UKA models (7.7 degrees vs. 3.6 degrees deviation). Varus misalignment of the femoral prosthesis was more influential than valgus for medial UKA kinematics, whereas in lateral UKA, a valgus misalignment of the femoral prosthesis was most influential on the kinematics. Resection of the cartilage in the medial compartment reduced the overall risk of progressive OA in the knee, whereas removing the cartilage from the lateral compartment, and in particular introducing a valgus femoral misalignment, increased the overall risk of progressive OA in the knee. Based on these results, under the conditions tested herein, both medial and lateral UKA can be said to induce kinematics of the knee which could be considered broadly comparable to those of the

  8. Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty.

    PubMed

    Marra, Marco A; Strzelczak, Marta; Heesterbeek, Petra J C; van de Groes, Sebastiaan A W; Janssen, Dennis; Koopman, Bart F J M; Verdonschot, Nico; Wymenga, Ate B

    2018-03-20

    When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to

  9. The Effects of Fluid Absorption on the Mechanical Properties of Joint Prostheses Components

    NASA Astrophysics Data System (ADS)

    Yarbrough, David; Viano, Ann

    2010-02-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) is the material playing the role of cartilage in human prosthetic joints. Wear debris from UHMWPE is a common reason for joint arthroplasty failure, and the exact mechanism responsible for wear remains an area of investigation. In this study, the microstructure of UHMWPE was examined as a function of fluid absorption. Samples with varying exposure to e-beam radiation (as part of the manufacturing process) were soaked for forty days in saline or artificial synovial fluid, under zero or 100 lbs load. Samples were then tensile-tested according to ASTM D-3895. The post-stressed material was then examined by transmission electron microscopy to evaluate the molecular response to stress, which correlates with macroscopic mechanical properties. Three parameters of the crystalline lamellae were measured: thickness, stacking ratio, and alignment to stress direction. Results indicate that fluid absorption does affect the mechanical properties of UHMWPE at both the microscopic and microscopic levels. )

  10. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    PubMed

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    PubMed Central

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These

  12. Changes in Health-Related Quality of Life and Knee Function After Knee Injury in Young Female Athletes.

    PubMed

    McGuine, Timothy A; Winterstein, Andrew P; Carr, Kathleen; Hetzel, Scott

    2014-04-01

    Recent literature has called for greater attention to evidence-based practice in sports medicine with the documentation of overall status and impairments following injury. The prospective documentation of impairments associated with knee injuries in female athletes regarding their health-related quality of life (HRQoL) and knee function (KF) of high school and collegiate athletes is limited. Assessing the effect knee injuries have on young female athletes may allow clinicians to better understand the perspectives of the athletes who sustain these injuries. To document the changes over 12 months in self-reported HRQoL and KF in young females who have sustained a knee injury. Case series; Level of evidence, 4. A convenience sample of 242 females (mean age, 17.4 ± 2.4 years) who injured their knee participating in sport or recreational activities was utilized. Injuries were categorized as anterior cruciate ligament tears (ACL), anterior knee pain (AKP), patellar instability (PAT), meniscus tear (MNT), iliotibial band syndrome (ITB), collateral ligament sprain (COL), and other (OTH). HRQoL was assessed with the Short Form-12 v 2.0 survey (SF-12) physical component summary (PCS) and mental component summary (MCS). KF was assessed with the 2000 International Knee Documentation Committee survey (IKDC). Dependent variables included the paired differences in the 2000 IKDC as well as SF-12 composite scores from preinjury through 12 months postdiagnosis. Paired differences were assessed with repeated-measures analyses of variance (P ≤ .05). IKDC scores were lower through 12 months for ACL, AKP, and PAT; through 6 months for MNT; and through 3 months for COL and OTH. HRQoL PCS and MCS scores were lower through 3 to 12 months depending on the type of injury classification. Knee injuries can negatively affect KF and HRQoL for up to 12 months in young females. Sports medicine providers need to be aware of these impacts as they work to effectively treat individuals with these

  13. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    PubMed

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Development of a Robust Static Punch Experiment for Screening Unprocessed Ultra-High Molecular Weight Polyethylene (UHMWPE) Unidirectional Cross-Ply Material

    DTIC Science & Technology

    2014-09-01

    Cross-Ply Material by David Gray, Robert Kaste , and Paul Moy ARL-TR-7090 September 2014...Screening Unprocessed Ultra-High Molecular Weight Polyethylene (UHMWPE) Unidirectional Cross-Ply Material David Gray, Robert Kaste , and Paul...ELEMENT NUMBER 6. AUTHOR(S) David Gray, Robert Kaste , and Paul Moy 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7

  15. Affects of Microgravity on the Polymerization and Material Properties of Biomedical Grade Polymers

    NASA Astrophysics Data System (ADS)

    Crane, Deborah J.

    2002-01-01

    the material of choice in the production of acetabular cups for hip and tibial cradles for knee orthopeadic implant components for over 30 years. Although UHMWPE is used for more than 1.5 million implants a year in the United States alone and more than 3 million implant surgeries a year worldwide, problems with debris particle formation, pitting and fracture continue to induce premature failure of implant components. chains produced during polymerization are capable of packing into crystalline structures called lamellae, which are embedded within randomly oriented amorphous regions. Crosslinks, or tie molecules bridge the crystalline structures, which contribute to the materials' toughness and strength as a biomedical material. Research has been conducted providing evidence that a crosslinked gradient at the articulating surface of the polymer component provides resistance to surface degradation and subsequent debris formation. Recently, the introduction of highly crosslinked UHMWPE had proven to reduce some of the problems associated with the applications of this polymer as a biomedical material and was seen as the answer to solving the continuing problems associated with UHMWPE implant components. Yet current research into the fatigue characteristics of highly crosslinked UHMWPE has shown that subsurface crack propagation and subsequent delamination continues to produce problematic debris generation. Studies have shown that various sterilization and accelerated aging (to emulate natural oxidation rates) protocols adversely effects the material properties. Additional research has shown that alignment of the lamellae, caused by processing technique, fabrication or surface articulation may be the precursor to debris particle formation. Processing techniques performed under high pressure has proven to effect the width of the crystalline lamellae and therefore, the material's response to wear and fracture. UHMWP due to a microgravity environment, which could be

  16. Experimental pre-clinical assessment of the primary stability of two cementless femoral knee components.

    PubMed

    Berahmani, Sanaz; Hendriks, Maartje; Wolfson, David; Wright, Abraham; Janssen, Dennis; Verdonschot, Nico

    2017-11-01

    To achieve long-lasting fixation of cementless implants, an adequate primary stability is required. We aimed to compare primary stability of a new cementless femoral knee component (Attune®) against a conventional implant (LCS®) under different loading conditions. Six pairs of femora were prepared following the normal surgical procedure. Calibrated CT-scans and 3D-optical scans of the bones were obtained to measure bone mineral density (BMD) and cut accuracy, respectively. Micromotions were measured in nine regions of interest at the bone-implant interface using digital image correlation. The reconstructions were subjected to the implant-specific's peak tibiofemoral load of gait and a deep knee bend loading profiles. Afterwards, the implants were pushed-off at a flexion angle of 150°. Micromotions of Attune were significantly lower than LCS under both loading conditions (P ≤ 0.001). Cut accuracy did not affect micromotions, and BMD was only a significant factor affecting the micromotions under simplified gait loading. No significant difference was found in high-flex push-off force, but Attune required a significantly higher load to generate excessive micromotions during push-off. Parallel anterior and posterior bone cuts in the LCS versus the tapered bone cuts of the Attune may explain the difference between the two designs. Additionally, the rims at the borders of the LCS likely reduced the area of contact with the bone for the LCS, which may have affected the initial fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Effect of Tibial Posterior Slope on Knee Kinematics, Quadriceps Force, and Patellofemoral Contact Force After Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Nakahara, Hiroyuki; Iwamoto, Yukihide

    2015-08-01

    We used a musculoskeletal model validated with in vivo data to evaluate the effect of tibial posterior slope on knee kinematics, quadriceps force, and patellofemoral contact force after posterior-stabilized total knee arthroplasty. The maximum quadriceps force and patellofemoral contact force decreased with increasing posterior slope. Anterior sliding of the tibial component and anterior impingement of the anterior aspect of the tibial post were observed with tibial posterior slopes of at least 5° and 10°, respectively. Increased tibial posterior slope contributes to improved exercise efficiency during knee extension, however excessive tibial posterior slope should be avoided to prevent knee instability. Based on our computer simulation we recommend tibial posterior slopes of less than 5° in posterior-stabilized total knee arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study.

    PubMed

    Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2012-08-01

    To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.

  19. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

    PubMed

    Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn

    2016-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability

    PubMed Central

    Gustafson, Jonathan A.; Gorman, Shannon; Fitzgerald, G. Kelley; Farrokhi, Shawn

    2017-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. PMID:26481256

  1. An Auto-Calibrating Knee Flexion-Extension Axis Estimator Using Principal Component Analysis with Inertial Sensors.

    PubMed

    McGrath, Timothy; Fineman, Richard; Stirling, Leia

    2018-06-08

    Inertial measurement units (IMUs) have been demonstrated to reliably measure human joint angles—an essential quantity in the study of biomechanics. However, most previous literature proposed IMU-based joint angle measurement systems that required manual alignment or prescribed calibration motions. This paper presents a simple, physically-intuitive method for IMU-based measurement of the knee flexion/extension angle in gait without requiring alignment or discrete calibration, based on computationally-efficient and easy-to-implement Principle Component Analysis (PCA). The method is compared against an optical motion capture knee flexion/extension angle modeled through OpenSim. The method is evaluated using both measured and simulated IMU data in an observational study ( n = 15) with an absolute root-mean-square-error (RMSE) of 9.24∘ and a zero-mean RMSE of 3.49∘. Variation in error across subjects was found, made emergent by the larger subject population than previous literature considers. Finally, the paper presents an explanatory model of RMSE on IMU mounting location. The observational data suggest that RMSE of the method is a function of thigh IMU perturbation and axis estimation quality. However, the effect size for these parameters is small in comparison to potential gains from improved IMU orientation estimations. Results also highlight the need to set relevant datums from which to interpret joint angles for both truth references and estimated data.

  2. Shape-memory-alloy-based smart knee spacer for total knee arthroplasty: 3D CAD modelling and a computational study.

    PubMed

    Gautam, Arvind; Callejas, Miguel A; Acharyya, Amit; Acharyya, Swati Ghosh

    2018-05-01

    This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), the pseudoelasticity (PE) and shape memory effect (SME), were exploited, modelled, and analysed for a TKA application. The effectiveness of the proposed model was verified in ANSYS Workbench through the finite element analysis (FEA) of the maximum deformation and equivalent (von Mises) stress distribution. The proposed model was also compared with a polymethylmethacrylate (PMMA)-based spacer for the upper portion of the tibial component for three subjects with body mass index (BMI) of 23.88, 31.09, and 38.39. The proposed SMA -based smart knee spacer contained 96.66978% less deformation with a standard deviation of 0.01738 than that of the corresponding PMMA based counterpart for the same load and flexion angle. Based on the maximum deformation analysis, the PMMA-based spacer had 30 times more permanent deformation than that of the proposed SMA-based spacer for the same load and flexion angle. The SME property of the lower portion of the tibial component for fixation of the spacer at its position was verified by an FEA in ANSYS. Wherein, a strain life-based fatigue analysis was performed and tested for the PE and SME built spacers through the FEA. Therefore, the SMA-based smart knee spacer eliminated the drawbacks of the PMMA-based spacer, including spacer fracture, loosening, dislocation, tilting or translation, and knee subluxation. Copyright © 2018. Published by Elsevier Ltd.

  3. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty--a combined analysis of tracer uptake distribution and component position.

    PubMed

    Suter, Basil; Testa, Enrique; Stämpfli, Patrick; Konala, Praveen; Rasch, Helmut; Friederich, Niklaus F; Hirschmann, Michael T

    2015-03-20

    The introduction of a standardized SPECT/CT algorithm including a localization scheme, which allows accurate identification of specific patterns and thresholds of SPECT/CT tracer uptake, could lead to a better understanding of the bone remodeling and specific failure modes of unicondylar knee arthroplasty (UKA). The purpose of the present study was to introduce a novel standardized SPECT/CT algorithm for patients after UKA and evaluate its clinical applicability, usefulness and inter- and intra-observer reliability. Tc-HDP-SPECT/CT images of consecutive patients (median age 65, range 48-84 years) with 21 knees after UKA were prospectively evaluated. The tracer activity on SPECT/CT was localized using a specific standardized UKA localization scheme. For tracer uptake analysis (intensity and anatomical distribution pattern) a 3D volumetric quantification method was used. The maximum intensity values were recorded for each anatomical area. In addition, ratios between the respective value in the measured area and the background tracer activity were calculated. The femoral and tibial component position (varus-valgus, flexion-extension, internal and external rotation) was determined in 3D-CT. The inter- and intraobserver reliability of the localization scheme, grading of the tracer activity and component measurements were determined by calculating the intraclass correlation coefficients (ICC). The localization scheme, grading of the tracer activity and component measurements showed high inter- and intra-observer reliabilities for all regions (tibia, femur and patella). For measurement of component position there was strong agreement between the readings of the two observers; the ICC for the orientation of the femoral component was 0.73-1.00 (intra-observer reliability) and 0.91-1.00 (inter-observer reliability). The ICC for the orientation of the tibial component was 0.75-1.00 (intra-observer reliability) and 0.77-1.00 (inter-observer reliability). The SPECT/CT algorithm

  4. Patient-specific instrumentation for total knee arthroplasty.

    PubMed

    Nabavi, Arash; Olwill, Caroline M; Do, Mike; Wanasawage, Tanya; Harris, Ian A

    2017-01-01

    To assess the accuracy of total knee replacements (TKRs) performed using CT-based patient-specific instrumentation by postoperative CT scan. Approval from the Ethics Committee was granted prior to commencement of this study. Fifty prospective and consecutive patients who had undergone TKR (Evolis, Medacta International) using CT-based patient-specific instrumentation (MY KNEE, Medacta International) were assessed postoperatively using a CT scan and the validated Perth protocol measurement technique. The hip-knee-ankle (HKA) angle of the lower limb in the coronal plane; the coronal, sagittal, and rotational orientation of the femoral component; and the coronal and sagittal orientation of the tibial component were measured. These results were then compared to each patient's preoperative planning. The percentage of patients found to be less than or equal to 3° of planned alignment was calculated. One patient was excluded as the femoral cutting block did not fit the femur as predicted by planning and therefore underwent a conventional TKR. Ninety-eight percent of patients were within 3° of planned alignment in the coronal plane reproducing the predicted HKA angle. Predicted coronal plane orientation of the tibial and femoral component was achieved in 100% and 96% of patients, respectively. The sagittal orientation of the femoral component was within 3° in 98% of patients. The planned sagittal positioning of the tibial component was achieved in 92% of patients. Furthermore, 90% of patients were found to have a femoral rotation within 3° of planning. Eighty-six percent of patients achieved good-to-excellent outcome at 12 months (Oxford Knee Score > 34). We have found that TKR using this patient-specific instrumentation accurately reproduces preoperative planning in all six of the parameters measured in this study.

  5. Intraoperative impaction of total knee replacements: an explicit finite-element-analysis of principal stresses in ceramic vs. cobalt-chromium femoral components.

    PubMed

    Kluess, Daniel; Mittelmeier, Wolfram; Bader, Rainer

    2010-12-01

    In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty. We generated an explicit finite-element-model to calculate the stresses developed under the highly dynamic intraoperative impaction with regard to cobalt-chromium and ceramic implant material as well as application of a silicone cover in order to reduce stress. The impaction was calculated with the hammer hitting the backside of the impactor at previously measured initial velocities. Subsequently the impactor, consisting of a steel handhold and a polyoxymethylene head, hit the femoral component. Instead of modelling femoral bone, the implant was mounted on four spring elements with spring constants previously determined in an experimental impaction model. The maximum principal stresses in the implants were evaluated at 8000 increments during the first 4 ms of impact. The ceramic implant showed principal stresses 10% to 48% higher than the cobalt chromium femoral component. The simulation of a 5mm thick silicone layer between the impactor and the femoral component showed a strong decrease of vibration resulting in a reduction of 54% to 68% of the maximum stress amounts. The calculated amounts of principal stress were beneath the ultimate bending strengths of each material. Based on the results, intraoperative fracture of femoral components in total knee replacement may not be caused solely by impaction, but also by contributing geometrical factors such as inadequate preparation of the distal femur. In order to minimize the influence of impaction related stress peaks we recommend limiting the velocity as well as the weight of the impaction hammer when inserting femoral components. The silicone cover seems to deliver a strong decrease of implant stress and should be considered in surgery technique in the future. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.

    PubMed

    Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R

    2007-01-01

    The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.

  7. Analysis of Carbon Fiber Reinforced PEEK Hinge Mechanism Articulation Components in a Rotating Hinge Knee Design: A Comparison of In Vitro and Retrieval Findings.

    PubMed

    Schierjott, Ronja A; Giurea, Alexander; Neuhaus, Hans-Joachim; Schwiesau, Jens; Pfaff, Andreas M; Utzschneider, Sandra; Tozzi, Gianluca; Grupp, Thomas M

    2016-01-01

    Carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) represents a promising alternative material for bushings in total knee replacements, after early clinical failures of polyethylene in this application. The objective of the present study was to evaluate the damage modes and the extent of damage observed on CFR-PEEK hinge mechanism articulation components after in vivo service in a rotating hinge knee (RHK) system and to compare the results with corresponding components subjected to in vitro wear tests. Key question was if there were any similarities or differences between in vivo and in vitro damage characteristics. Twelve retrieved RHK systems after an average of 34.9 months in vivo underwent wear damage analysis with focus on the four integrated CFR-PEEK components and distinction between different damage modes and classification with a scoring system. The analysis included visual examination, scanning electron microscopy, and energy dispersive X-ray spectroscopy, as well as surface roughness and profile measurements. The main wear damage modes were comparable between retrieved and in vitro specimens ( n = 3), whereby the size of affected area on the retrieved components showed a higher variation. Overall, the retrieved specimens seemed to be slightly heavier damaged which was probably attributable to the more complex loading and kinematic conditions in vivo.

  8. Current surgical strategies for total arthroplasty in valgus knee

    PubMed Central

    Nikolopoulos, Dimitrios; Michos, Ioannis; Safos, George; Safos, Petros

    2015-01-01

    The majority of orthopaedic surgeons even currently agree that primary total arthroplasty in valgus knees with a deformity of more than ten degrees may prove challenging. The unique sets of bone and soft tissue abnormalities that must be addressed at the time of the operation make accurate axis restoration, component orientation and joint stability attainment a difficult task. Understanding the specific pathologic anatomic changes associated with the valgus knee is a prerequisite so as to select the proper surgical method, to optimize component position and restore soft-tissue balance. The purpose of this article is to review the valgus knee anatomical variations, to assess the best pre-operative planning and to evaluate how to choose the grade of constraint of the implant. It will also be underlying the up-to-date main approaches and surgical techniques be proposed in the English literature both for bone cuts and soft tissue management of valgus knees. PMID:26191494

  9. Association of Baseline Knee Sagittal Dynamic Joint Stiffness during Gait and 2-year Patellofemoral Cartilage Damage Worsening in Knee Osteoarthritis

    PubMed Central

    Chang, Alison H.; Chmiel, Joan S.; Almagor, Orit; Guermazi, Ali; Prasad, Pottumarthi V.; Moisio, Kirsten C.; Belisle, Laura; Zhang, Yunhui; Hayes, Karen; Sharma, Leena

    2016-01-01

    Objective Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Methods Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs. angles during the loading response phase. Knee MRI scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations. Results Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); BMI 28.4 kg/m2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR=5.35, 95% CI: 2.37–12.05) and any PF (OR=2.99, 95% CI: 1.27–7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Conclusion Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. PMID:27729289

  10. Ceramic femoral component fracture in total knee arthroplasty: an analysis using fractography, fourier-transform infrared microscopy, contact radiography and histology.

    PubMed

    Krueger, Alexander P; Singh, Gurpal; Beil, Frank Timo; Feuerstein, Bernd; Ruether, Wolfgang; Lohmann, Christoph H

    2014-05-01

    Ceramic components in total knee arthroplasty (TKA) are evolving. We analyze the first case of BIOLOX delta ceramic femoral component fracture. A longitudinal midline fracture in the patellar groove was present, with an intact cement mantle and no bony defects. Fractographic analysis with laser scanning microscopy and white light interferometry showed no evidence of arrest lines, hackles, wake hackles, material flaws, fatigue or crack propagation. Analysis of periprosthetic tissues with Fourier-transform infrared (FT-IR) microscopy, contact radiography, histology, and subsequent digestion and high-speed centrifugation did not show ceramic debris. A macrophage-dominated response was present around polyethylene debris. We conclude that ceramic femoral component failure in this case was related to a traumatic event. Further research is needed to determine the suitability of ceramic components in TKA. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Stiffness after total knee arthroplasty.

    PubMed

    Manrique, Jorge; Gomez, Miguel M; Parvizi, Javad

    2015-04-01

    Stiffness after total knee arthroplasty (TKA) adversely affects outcome and impacts patient function. Various risk factors for stiffness after TKA have been identified, including reduced preoperative knee range of motion, history of prior knee surgery, etiology of arthritis, incorrect positioning or oversizing of components, and incorrect gap balancing. Mechanical and associated causes, such as infection, arthrofibrosis, complex regional pain syndrome, and heterotopic ossification, secondary gain issues have also been identified. Management of stiffness following TKA can be challenging. The condition needs to be assessed and treated in a staged manner. A nonsurgical approach is the first step. Manipulation under anesthesia may be considered within the first 3 months after the index TKA, if physical therapy fails to improve the range of motion. Beyond this point, consideration should be given to surgical intervention such as lysis of adhesions, either arthroscopically or by open arthrotomy. If the cause of stiffness is deemed to be surgical error, such as component malpositioning, revision arthroplasty is indicated. The purpose of this article is to evaluate the various aspects of management of stiffness after TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Clinical practice guidelines for rest orthosis, knee sleeves, and unloading knee braces in knee osteoarthritis.

    PubMed

    Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François

    2009-12-01

    To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.

  13. Biotribological behavior of Ag-ZrCxN1-x coatings against UHMWPE for joint prostheses devices.

    PubMed

    Calderon V, S; Sánchez-López, J C; Cavaleiro, A; Carvalho, S

    2015-01-01

    This study aims to evaluate the structural, mechanical and tribological properties of zirconium carbonitrides (ZrCxN1-x) coatings with embedded silver nanoparticles, produced with the intention of achieving a material with enhanced multi-functional properties, including mechanical strength, corrosion resistance, tribological performance and antibacterial behavior suitable for their use in joint prostheses. The coatings were deposited by direct current (DC) reactive magnetron sputtering onto 316 L stainless steel, changing the silver content from 0 to 20 at% by modifying the current density applied to the targets. Different nitrogen and acetylene gas fluxes were used as reactive gases. The coatings revealed different mixtures of crystalline ZrCxN1-x, silver nanoparticles and amorphous carbon phases. The hardness of the films was found to be mainly controlled by the ratio between the hard (ZrCxN1-x) and soft (Ag and amorphous carbon) phases in the films, fluctuating between 7.4 and 20.4 GPa. The coefficient of friction, measured against ultra-high molecular weight polyethylene (UHMWPE) in Hank's balanced salt solution with 10 gL(-1) albumin, is governed by the surface roughness and hardness. The UHMWPE wear rates were in the same order of magnitude (between 1.4 and 2.0 × 10(-6)mm(3)N(-1)m(-1)), justified by the effect of the protective layer of albumin formed during the tests. The small differences were due to the hydrophobic/hydrophilic character of the surface, as well as to the silver content. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    PubMed

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Predicting Satisfaction for Unicompartmental Knee Arthroplasty Patients in an Asian Population.

    PubMed

    Lee, Merrill; Huang, Yilun; Chong, Hwei Chi; Ning, Yilin; Lo, Ngai Nung; Yeo, Seng Jin

    2016-08-01

    Despite renewed interest in unicompartmental knee arthroplasty (UKA), there is a paucity of published literature with regard to patient satisfaction after UKA within Asian populations. The purpose of this study is to identify characteristics and factors which may contribute to patient dissatisfaction after UKA in a multiracial Asian population. Seven hundred twenty-four UKAs were performed between January 2007 and April 2013. Preoperative and postoperative variables were prospectively captured, such as standardized knee scores, knee range of motion, and patient satisfaction scores. These variables were then analyzed with a multiple logistic regression model to determine statistically significant factors contributing to patients' satisfaction. Minimum duration of follow-up was 2 years, with an overall patient satisfaction rate of 92.2%. There was improvement in mean knee range of motion and across various standardized knee scores. Preoperative variables associated with patient dissatisfaction included a poorer preoperative Mental Component Summary, better preoperative knee extension, and better preoperative Oxford Knee Scores. Significant postoperative variables included better Oxford Knee Score at 6 months and Mental Component Summary at 2 years. Despite the impressive patient satisfaction rate of UKA in this Asian population, these findings suggest that there is a targeted group of patients with select preoperative factors who would benefit from preoperative counseling. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Association of baseline knee sagittal dynamic joint stiffness during gait and 2-year patellofemoral cartilage damage worsening in knee osteoarthritis.

    PubMed

    Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L

    2017-02-01

    Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  17. The Oxford unicompartmental knee fails at a high rate in a high-volume knee practice.

    PubMed

    Schroer, William C; Barnes, C Lowry; Diesfeld, Paul; LeMarr, Angela; Ingrassia, Rachel; Morton, Diane J; Reedy, Mary

    2013-11-01

    The Oxford knee is a unicompartmental implant featuring a mobile-bearing polyethylene component with excellent long-term survivorship results reported by the implant developers and early adopters. By contrast, other studies have reported higher revision rates in large academic practices and in national registries. Registry data have shown increased failure with this implant especially by lower-volume surgeons and institutions. In the setting of a high-volume knee arthroplasty practice, we sought to determine (1) the failure rate of the Oxford unicompartmental knee implant using a failure definition for aseptic loosening that combined clinical features, plain radiographs, and scintigraphy, and (2) whether increased experience with this implant would decrease failure rate, if there is a learning curve effect. Eighty-three Oxford knee prostheses were implanted between September 2005 and July 2008 by the principal investigator. Radiographic and clinical data were available for review for all cases. A failed knee was defined as having recurrent pain after an earlier period of recovery from surgery, progressive radiolucent lines compared with initial postoperative radiographs, and a bone scan showing an isolated area of uptake limited to the area of the replaced compartment. Eleven knees in this series failed (13%); Kaplan-Meier survivorship was 86.5% (95% CI, 78.0%-95.0%) at 5 years. Failure occurrences were distributed evenly over the course of the study period. No learning curve effect was identified. Based on these findings, including a high failure rate of the Oxford knee implant and the absence of any discernible learning curve effect, the principal investigator no longer uses this implant.

  18. Factors affecting femoral rotational angle based on the posterior condylar axis in gap-based navigation-assisted total knee arthroplasty for valgus knee.

    PubMed

    Lee, Sung-Sahn; Lee, Yong-In; Kim, Dong-Uk; Lee, Dae-Hee; Moon, Young-Wan

    2018-01-01

    Achieving proper rotational alignment of the femoral component in total knee arthroplasty (TKA) for valgus knee is challenging because of lateral condylar hypoplasia and lateral cartilage erosion. Gap-based navigation-assisted TKA enables surgeons to determine the angle of femoral component rotation (FCR) based on the posterior condylar axis. This study evaluated the possible factors that affect the rotational alignment of the femoral component based on the posterior condylar axis. Between 2008 and 2016, 28 knees were enrolled. The dependent variable for this study was FCR based on the posterior condylar axis, which was obtained from the navigation system archives. Multiple regression analysis was conducted to identify factors that might predict FCR, including body mass index (BMI), Kellgren-Lawrence grade (K-L grade), lateral distal femoral angles obtained from the navigation system and radiographs (NaviLDFA, XrayLDFA), hip-knee-ankle (HKA) axis, lateral gap under varus stress (LGVS), medial gap under valgus stress (MGVS), and side-to-side difference (STSD, MGVS - LGVS). The mean FCR was 6.1° ± 2.0°. Of all the potentially predictive factors evaluated in this study, only NaviLDFA (β = -0.668) and XrayLDFA (β = -0.714) predicted significantly FCR. The LDFAs, as determined using radiographs and the navigation system, were both predictive of the rotational alignment of the femoral component based on the posterior condylar axis in gap-based TKA for valgus knee. A 1° increment with NaviLDFA led to a 0.668° decrement in FCR, and a 1° increment with XrayLDFA led to a 0.714° decrement. This suggests that symmetrical lateral condylar hypoplasia of the posterior and distal side occurs in lateral compartment end-stage osteoarthritis with valgus deformity.

  19. Development of biomimetic in vitro fatigue assessment for UHMWPE implant materials.

    PubMed

    Scholz, Ronja; Knyazeva, Marina; Porchetta, Dario; Wegner, Nils; Senatov, Fedor; Salimon, Alexey; Kaloshkin, Sergey; Walther, Frank

    2018-05-26

    An important research goal in the field of biomaterials lies in the progressive amendment of in vivo tests with suitable in vitro experiments. Such approaches are gaining more significance nowadays because of an increasing demand on life sciences and the ethical issues bound to the sacrifice of animals for the sake of scientific research. Another advantage of transferring the experiments to the in vitro field is the possibility of accurately control the boundary conditions and experimental parameters in order to reduce the need of validation tests involving animals. With the aim to reduce the amount of needed in vivo studies for this cause, a short-time in vitro test procedure using instrumented load increase tests with superimposed environmental loading has been developed at TUD to assess the mechanical long-term durability of ultra-high molecular weight polyethylene (UHMWPE) under fatigue loading in a biological environment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Oral hyaluronan relieves knee pain: a review.

    PubMed

    Oe, Mariko; Tashiro, Toshiyuki; Yoshida, Hideto; Nishiyama, Hiroshi; Masuda, Yasunobu; Maruyama, Koh; Koikeda, Takashi; Maruya, Reiko; Fukui, Naoshi

    2016-01-27

    Hyaluronan (HA) is a component that is particularly abundant in the synovial fluid. Randomized, double-blinded, placebo-controlled trials carried out between 2008 and 2015 have proven the effectiveness of HA for the treatment of symptoms associated with synovitis, and particularly, knee pain, relief of synovial effusion or inflammation, and improvement of muscular knee strength. The mechanism by which HA exerts its effects in the living body, specifically receptor binding in the intestinal epithelia, has gradually been clarified. This review examines the effects of HA upon knee pain as assessed in clinical trials, as well as the mechanism of these effects and the safety of HA.

  1. Evaluation of a bisphosphonate enriched ultra-high molecular weight polyethylene for enhanced total joint replacement bearing surface functionality

    NASA Astrophysics Data System (ADS)

    Wright-Walker, Cassandra Jane

    Each year in the United States there is an increasing trend of patients receiving total joint replacement (TJR) procedures. Approximately a half million total knee replacements (TKRs) are performed annually in the United States with increasing prevalence attributed to baby-boomers, obesity, older, and younger patients. This trend is also seen for total hip replacements (THRs) as well. The use of ultra high molecular weight polyethylene (UHMWPE) inserts in TJRs results in wear particle-induced osteolysis, which is the predominant cause for prosthesis failure and revision surgery. Sub-micron size particle generation is inevitable despite the numerous efforts in improving this bearing material. Work by others has shown that the use of oral and intravenous systemic bisphosphonates (BP) can significantly minimize periprosthetic osteolysis. However, the systemic delivery and the high solubility of BPs results in a predominant portion of the drug being excreted via the kidney without reaching its target, bone. This doctoral research project is focused on the development and evaluation of a novel method to administer BPs locally using the inherent wear of UHMWPE for possible use as an anti-osteolysis treatment. For new materials to be considered, they must be mechanically and tribologically comparable to the current gold standard, UHMWPE. In order to evaluate this material, mechanical, drug elution and tribological experiments were performed to allow assessment of material properties. Tensile tests showed comparable yield stress and pin-on-disk testing showed comparable wear to standard virgin UHMWPE. Further, drug elution tests have shown that BP was released from the enriched material both in static and dynamic conditions. Additionally, an aggressive 2 million cycle total knee simulator experiment has shown statistically similar wear results for the two materials. Overall, this research has provided the groundwork for further characterization and development of a new

  2. Swollen Knee (Water on the Knee)

    MedlinePlus

    ... your knee joint. Some people call this condition "water on the knee." A swollen knee may be ... Choose low-impact exercise. Certain activities, such as water aerobics and swimming, don't place continuous weight- ...

  3. Knee stabilisation following infected knee arthroplasty with bone loss and extensor mechanism impairment using a modular cemented nail.

    PubMed

    Rao, M C; Richards, O; Meyer, C; Jones, R Spencer

    2009-12-01

    Infected Total Knee Replacement with significant bone loss and loss of extensor mechanism poses a difficult management problem. Arthrodesis relying on bony union can be difficult to achieve and can result in significant limb shortening. We retrospectively looked at the outcome of seven patients with significant bone loss and extensor mechanism insufficiency following infected TKR who underwent knee stabilisation using a modular cemented nail. The nail relied on the strong coupling mechanism between the modular femoral and tibial components. Pain score improved from a mean of 7.9 pre-operatively to 1.5 post-operatively at a mean follow up of 39.6 months (range 7-68) months. Two patients underwent technically easy revision nailing for recurrent infection and aseptic loosening. The Endo-Model(R) Knee Fusion Nail (Newsplint, UK/Waldemar Link, GmbH & Co. KG, Hamburg, Germany) has good early results in terms of pain relief and provides a stable knee in cases with significant bone loss and extensor mechanism insufficiency following an infected TKR thus avoiding an above knee amputation.

  4. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    PubMed

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  5. Accuracy verification of the photostereometric system KKN/1B developed for intraoperative measurement of knee movement immediately after total knee arthroplasty.

    PubMed

    Nishino, K; Hayashi, T; Suzuki, Y; Koga, Y; Omori, G

    1999-01-01

    The function and integrity of the knee joint following total knee arthroplasty (TKA) is determined at first by the design and implantation of the prosthesis, and later by the tension of soft tissues surrounding it. Accurate post-TKA motion data obtained intraoperatively could be used not only to optimize implantation techniques from a kinematic standpoint, but also to improve prosthetic design. We therefore developed a system specifically geared to photostereometric measurement of 6 d.o.f. knee motion. A total of eight LEDs are mounted on the prosthetic components in two sets of four by means of connecting measuring-bows. The positions of the LEDs are detected in three-dimensions by two sets of three linear CCD cameras, located bilaterally relative to the knee. The position and orientation of the femoral component relative to the tibial one are estimated from the positions of all LEDs in the sense of least-squares. Based upon results of various accuracy validation experiments performed after precise camera calibration, static overall accuracy and spatial resolution were considered to lie within 0.52 and 0.11 mm, respectively, at any point on the femoral articular surface.

  6. Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty.

    PubMed

    Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Tashiro, Yasutaka; Nakahara, Hiroyuki; Iwamoto, Yukihide

    2016-01-01

    The first purpose of this study was to compare the reproducibility of two-dimensional (2D) and three-dimensional (3D) measurements for preoperative planning of the femoral side in total knee arthroplasty (TKA). The second purpose was to evaluate the factors affecting the differences between the 2D and 3D measurements. Two-dimensional and 3D measurements for preoperative planning of the femoral side in TKA were evaluated in 75 varus knees with osteoarthritis. The femoral valgus angle, defined as the angle between the mechanical and anatomical axes of the femur, and the clinical rotation angle and surgical rotation angle, defined by the angles between the posterior condylar line and the clinical or surgical transepicondylar axes, respectively, were analysed using 2D (radiographs and axial CT slices) and 3D (3D bone models reconstructed from CT images) measurements. For all variables, 3D measurements were more reliable and reproducible than 2D measurements. The medians and ranges of the clinical rotation angle and surgical rotation angle were 6.6° (-1.7° to 12.1°) and 2.3° (-2.5° to 8.6°) in 2D, and 7.1° (2.7° to 11.4°) and 3.0° (-2.0° to 7.5°) in 3D. Varus/valgus alteration of the CT scanning direction relative to the mechanical axis affected the difference in clinical rotation angles between 2D and 3D measurements. Significantly, smaller values of the clinical rotation angle and surgical rotation angle were obtained by 2D compared to 3D measurements, which could result in internal rotation of the femoral component even if the surgeon performs the bone cutting precisely. Regarding clinical relevance, first, this study confirmed the reliability of 3D measurements. Second, it underscored the risk of internal rotation of the femoral component when using 2D measurement, even with precise bone cutting technique. These results will help surgeons avoid malpositioning of the femoral component if 2D measurements are used for preoperative planning in TKA

  7. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications.

    PubMed

    Berni, M; Lopomo, N; Marchiori, G; Gambardella, A; Boi, M; Bianchi, M; Visani, A; Pavan, P; Russo, A; Marcacci, M

    2016-05-01

    One of the most important issues leading to the failure of total joint arthroplasty is related to the wear of the plastic components, which are generally made of ultra high molecular weight polyethylene (UHMWPE). Therefore, the reduction of joint wear represents one of the main challenges the research in orthopedics is called to address nowadays. Surface treatments and coatings have been recognized as innovative methods to improve tribological properties, also in the orthopedic field. This work investigated the possibility to realize hard ceramic coatings on the metal component of a prosthesis, by means of Pulsed Plasma Deposition, in order to reduce friction and wear in the standard coupling against UHMWPE. Ti6Al4V substrates were coated with a 2 μm thick yttria-stabilized zirconia (YSZ) layer. The mechanical properties of the YSZ coatings were assessed by nanoindentation tests performed on flat Ti6Al4V substrates. Tribological performance was evaluated using a ball-on-disk tribometer in dry and lubricated (i.e. with fetal bovine serum) highly-stressing conditions, up to an overall distance of 10 km. Tribology was characterized in terms of coefficient of friction (CoF) and wear rate of the UHMWPE disk. After testing, specimens were analyzed through optical microscopy and SEM images, in order to check the wear degradation mechanisms. Progressive loading scratch tests were also performed in dry and wet conditions to determine the effects of the environment on the adhesion of the coating. Our results supported the beneficial effect of YSZ coating on metal components. In particular, the proposed solution significantly reduced UHMWPE wear rate and friction. At 10 km of sliding distance, a wear rate reduction of about 18% in dry configuration and of 4% in presence of serum, was obtained by the coated group compared to the uncoated group. As far as friction in dry condition is concerned, the coating allowed to maintain low CoF values until the end of the tests, with an

  8. Radiation-induced graft polymerization for the preparation of a highly efficient UHMWPE fibrous adsorbent for Cr(VI) removal

    NASA Astrophysics Data System (ADS)

    Gao, Qianhong; Hua, Jiangtao; Li, Rong; Xing, Zhe; Pang, Lijuan; Zhang, Mingxing; Xu, Lu; Wu, Guozhong

    2017-01-01

    A novel fibrous adsorbent containing amine and quaternary ammonium groups was prepared by radiation-induced graft of glycidyl methacrylate (GMA) onto ultra-high molecular weight polyethylene (UHMWPE) fiber and further modifying with triethylenetetramine (TETA) and glycidyl trimethylammonium chloride (GTA). The ATR-IR spectra and SEM observation demonstrated that amine and quaternary ammonium groups were immobilized onto the surface of UHMWPE fiber. The principal factors affecting the adsorption of Cr(VI) ions have been investigated including pH of the aqueous solution, contact time, temperature and coexisting anions. This novel fibrous adsorbent could effectively adsorb Cr(VI) in the range of pH 1-9, and the maximum adsorption capacity reached 295 mg/g at pH 3 and 25 °C based on the Langmuir isotherm. It was found that adsorption equilibrium could be achieved within 2 h for initial Cr(VI) of 100 mg/L, following the pseudo-second order model. The effect of coexisting anions (including SO42-, H2PO4-, NO3-and Cl-) on the uptake of Cr(VI) was investigated in detail. Additionally, the adsorption saturated fiber could be regenerated by soaking in 0.5 mol/L NaOH solution, and the adsorption performance of this adsorbent could be maintained at 90% after eight cycles of adsorption-desorption. ATR-IR and XPS analysis revealed that Cr(VI) ions were adsorbed on the fiber adsorbent through ion exchange mechanism.

  9. Raman spectroscopy of biomedical polyethylenes.

    PubMed

    Pezzotti, Giuseppe

    2017-06-01

    With the development of three-dimensional Raman algorithms for local mapping of oxidation and plastic strain, and the ability to resolve molecular orientation patterns with microscopic spatial resolution, there is an opportunity to re-examine many of the foundations on which our understanding of biomedical grade ultra-high molecular weight polyethylenes (UHMWPEs) are based. By implementing polarized Raman spectroscopy into an automatized tool with an improved precision in non-destructively resolving Euler angles, oxidation levels, and microscopic strain, we become capable to make accurate and traceable measurements of the in vitro and in vivo tribological responses of a variety of commercially available UHMWPE bearings for artificial hip and knee joints. In this paper, we first review the foundations and the main algorithms for Raman analyses of oxidation and strain of biomedical polyethylene. Then, we critically re-examine a large body of Raman data previously collected on different polyethylene joint components after in vitro testing or in vivo service, in order to shed new light on an area of particular importance to joint orthopedics: the microscopic nature of UHMWPE surface degradation in the human body. A complex scenario of physical chemistry appears from the Raman analyses, which highlights the importance of molecular-scale phenomena besides mere microstructural changes. The availability of the Raman microscopic probe for visualizing oxidation patterns unveiled striking findings related to the chemical contribution to wear degradation: chain-breaking and subsequent formation of carboxylic acid sites preferentially occur in correspondence of third-phase regions, and they are triggered by emission of dehydroxylated oxygen from ceramic oxide counterparts. These findings profoundly differ from more popular (and simplistic) notions of mechanistic tribology adopted in analyzing joint simulator data. Statement of Significance This review was dedicated to the

  10. Micro-Raman spectroscopy for the crystallinity characterization of UHMWPE hip cups run on joint simulators

    NASA Astrophysics Data System (ADS)

    Bertoluzza, A.; Fagnano, C.; Rossi, M.; Tinti, A.; Cacciari, G. L.

    2000-03-01

    In this work Raman microspectrometry was used to evaluate the crystallinity changes of hip cups made of ultra-high molecular weight polyethylene (UHMWPE). In vitro experiments were carried out using hip joint movement-wear simulators, run for five million cycles in water or bovine calf serum. The hip cups were subjected to mechanical friction with ceramic femoral heads (alumina-zirconia blend). The crystallinity of the polymer hip cups was studied as a function of inner surface position and thickness, from the stressed surface to the unstressed outer one. The Partial Least Square (PLS-l) calibration was used to correlate the Raman spectra with the crystallinity of the polymer measured with DSC calorimetry.

  11. The role of knee joint moments and knee impairments on self-reported knee pain during gait in patients with knee osteoarthritis.

    PubMed

    O'Connell, Megan; Farrokhi, Shawn; Fitzgerald, G Kelley

    2016-01-01

    The association between high mechanical knee joint loading during gait with onset and progression of knee osteoarthritis has been extensively studied. However, less attention has been given to risk factors related to increased pain during gait. The purpose of this study was to evaluate knee joint moments and clinical characteristics that may be associated with gait-related knee pain in patients with knee osteoarthritis. Sixty-seven participants with knee osteoarthritis were stratified into three groups of no pain (n=18), mild pain (n=27), or moderate/severe pain (n=22) based on their self-reported symptoms during gait. All participants underwent three-dimensional gait analysis. Quadriceps strength, knee extension range of motion, radiographic knee alignment and self-reported measures of global pain and function were also quantified. The moderate/severe pain group demonstrated worse global pain (P<0.01) and physical function scores (P<0.01) compared to the no pain and the mild pain groups. The moderate/severe pain group also walked with greater knee flexion moments during the midstance phase of gait compared to the no pain group (P=0.02). Additionally, the moderate/severe pain group demonstrated greater varus knee malalignment (P=0.009), which was associated with higher weight acceptance peak knee adduction moments (P=0.003) and worse global pain (P=0.003) and physical function scores (P=0.006). Greater knee flexion moment is present during the midstance phase of gait in patients with knee osteoarthritis and moderate/severe pain during gait. Additionally, greater varus malalignment may be a sign of increased global knee joint dysfunction that can influence many activities of daily living beyond gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Does Maximal External Tibial Component Rotation Influence Tibiofemoral Load Distribution in the Primary Knee Arthroplasty Setting: A Comparison of Neutral vs Maximal Anatomical External Rotatory States.

    PubMed

    Manning, William A; Ghosh, Kanishka M; Blain, Alasdair P; Longstaff, Lee M; Rushton, Steven P; Deehan, David J

    2017-06-01

    Tibial component rotation at time of knee arthroplasty can influence conformity, load transmission across the polyethylene surface, and perhaps ultimately determined survivorship. Optimal tibial component rotation on the cut surface is reliant on standard per operative manual stressing. This subjective assessment aims to balance constraint and stability of the articulation through a full arc of movement. Using a cadaveric model, computer navigation and under defined, previously validated loaded conditions mimicking the in vivo setting, the influence of maximal tibial component external rotation compared with the neutral state was examined for changes in laxity and tibiofemoral continuous load using 3D displacement measurement and an orthosensor continuous load sensor implanted within the polyethylene spacer in a simulated single radius total knee arthroplasty. No significant difference was found throughout arc of motion (0-115 degrees of flexion) for maximal varus and/or valgus or rotatory laxity between the 2 states. The neutral state achieved equivalence for mediolateral load distribution at each point of flexion. We have found that external rotation of the tibial component increased medial compartment load in comparison with the neutral position. Compared with the neutral state, external rotation consistently effected a marginal, but not significant reduction in lateral load under similar loading conditions. The effects were most pronounced in midflexion. On the basis of these findings, we would advocate for the midtibial tubercle point to determine tibial component rotation and caution against component external rotation. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    PubMed Central

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  14. Five year survival analysis of an oxidised zirconium total knee arthroplasty.

    PubMed

    Holland, Philip; Santini, Alasdair J A; Davidson, John S; Pope, Jill A

    2013-12-01

    Zirconium total knee arthroplasties theoretically have a low incidence of failure as they are low friction, hard wearing and hypoallergenic. We report the five year survival of 213 Profix zirconium total knee arthroplasties with a conforming all polyethylene tibial component. Data was collected prospectively and multiple strict end points were used. SF12 and WOMAC scores were recorded pre-operatively, at three months, at twelve months, at 3 years and at 5 years. Eight patients died and six were "lost to follow-up". The remaining 199 knees were followed up for five years. The mean WOMAC score improved from 56 to 35 and the mean SF12 physical component score improved from 28 to 34. The five year survival for failure due to implant related reasons was 99.5% (95% CI 97.4-100). This was due to one tibial component becoming loose aseptically in year zero. Our results demonstrate that the Profix zirconium total knee arthroplasty has a low medium term failure rate comparable to the best implants. Further research is needed to establish if the beneficial properties of zirconium improve long term implant survival. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    PubMed

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (P<0.05). The pre-operative malalignment of the knee was corrected (P<0.05), and the ankle tilt angle was accordingly improved in the operative side after TKA (P<0.05). In addition, TKA had little effect on knee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. The Parameters Affecting the Success of Irrigation and Debridement with Component Retention in the Treatment of Acutely Infected Total Knee Arthroplasty

    PubMed Central

    Kim, Jae Gyoon; Bae, Ji Hoon; Lee, Seung Yup; Cho, Won Tae

    2015-01-01

    Background The aims of our study were to evaluate the success rate of irrigation and debridement with component retention (IDCR) for acutely infected total knee arthroplasty (TKA) (< 4 weeks of symptom duration) and to analyze the factors affecting prognosis of IDCR. Methods We retrospectively reviewed 28 knees treated by IDCR for acutely infected TKA from 2003 to 2012. We evaluated the success rate of IDCR. All variables were compared between the success and failure groups. Multivariable logistic regression analysis was also used to examine the relative contribution of these parameters to the success of IDCR. Results Seventeen knees (60.7%) were successfully treated. Between the success and failure groups, there were significant differences in the time from primary TKA to IDCR (p = 0.021), the preoperative erythrocyte sedimentation rate (ESR; p = 0.021), microorganism (p = 0.006), and polyethylene liner exchange (p = 0.017). Multivariable logistic regression analysis of parameters affecting the success of IDCR demonstrated that preoperative ESR (odds ratio [OR], 1.02; p = 0.041), microorganism (OR, 12.4; p = 0.006), and polyethylene liner exchange (OR, 0.07; p = 0.021) were significant parameters. Conclusions The results show that 60.7% of the cases were successfully treated by IDCR for acutely infected TKA. The preoperative ESR, microorganism, and polyethylene liner exchange were factors that affected the success of IDCR in acutely infected TKA. PMID:25729521

  17. Robotic-Assisted Knee Arthroplasty: An Overview.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Pearle, Andrew D

    2016-01-01

    Unicompartmental knee arthroplasty and total knee arthroplasty are reliable treatment options for osteoarthritis. In order to improve survivorship rates, variables that are intraoperatively controlled by the orthopedic surgeon are being evaluated. These variables include lower leg alignment, soft tissue balance, joint line maintenance, and tibial and femoral component alignment, size, and fixation methods. Since tighter control of these factors is associated with improved outcomes of knee arthroplasty, several computer-assisted surgery systems have been developed. These systems differ in the number and type of variables they control. Robotic-assisted systems control these aforementioned variables and, in addition, aim to improve the surgical precision of the procedure. Robotic-assisted systems are active, semi-active, or passive, depending on how independently the systems perform maneuvers. Reviewing the robotic-assisted knee arthroplasty systems, it becomes clear that these systems can accurately and reliably control the aforementioned variables. Moreover, these systems are more accurate and reliable in controlling these variables when compared to the current gold standard of conventional manual surgery. At present, few studies have assessed the survivorship and functional outcomes of robotic-assisted surgery, and no sufficiently powered studies were identified that compared survivorship or functional outcomes between robotic-assisted and conventional knee arthroplasty. Although preliminary outcomes of robotic-assisted surgery look promising, more studies are necessary to assess if the increased accuracy and reliability in controlling the surgical variables leads to better outcomes of robotic-assisted knee arthroplasty.

  18. Adhesive strength of total knee endoprostheses to bone cement - analysis of metallic and ceramic femoral components under worst-case conditions.

    PubMed

    Bergschmidt, Philipp; Dammer, Rebecca; Zietz, Carmen; Finze, Susanne; Mittelmeier, Wolfram; Bader, Rainer

    2016-06-01

    Evaluation of the adhesive strength of femoral components to the bone cement is a relevant parameter for predicting implant safety. In the present experimental study, three types of cemented femoral components (metallic, ceramic and silica/silane-layered ceramic) of the bicondylar Multigen Plus knee system, implanted on composite femora were analysed. A pull-off test with the femoral components was performed after different load and several cementing conditions (four groups and n=3 components of each metallic, ceramic and silica/silane-layered ceramic in each group). Pull-off forces were comparable for the metallic and the silica/silane-layered ceramic femoral components (mean 4769 N and 4298 N) under standard test condition, whereas uncoated ceramic femoral components showed reduced pull-off forces (mean 2322 N). Loading under worst-case conditions led to decreased adhesive strength by loosening of the interface implant and bone cement using uncoated metallic and ceramic femoral components, respectively. Silica/silane-coated ceramic components were stably fixed even under worst-case conditions. Loading under high flexion angles can induce interfacial tensile stress, which could promote early implant loosening. In conclusion, a silica/silane-coating layer on the femoral component increased their adhesive strength to bone cement. Thicker cement mantles (>2 mm) reduce adhesive strength of the femoral component and can increase the risk of cement break-off.

  19. Bone scan features in spontaneous knee pain.

    PubMed

    Vattimo, A; Merlo, F; Bertelli, P; Burroni, L

    1992-01-01

    In 21 patients with "spontaneous" knee pain, 99mTc-MDP bone scan was found to be more sensitive than clinical and radiographic examination in detecting alterations of the joint components. These alterations were shown by increased radionuclide uptake in the compartments where pain was present, which was most commonly the medial femorotibial compartment, although the femoropatellar compartment was also frequently affected. The authors conclude that bone scan should be the first imaging study performed on the knee in order to establish if further tests are necessary.

  20. Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy.

    PubMed

    Saxena, Vishal; Anari, Jason B; Ruutiainen, Alexander T; Voleti, Pramod B; Stephenson, Jason W; Lee, Gwo-Chin

    2016-08-01

    Restoration of normal anatomy and proper ligament balance are theoretical prerequisites for reproducing physiological kinematics with bicruciate-retaining total knee arthroplasty (TKA). The purpose of this study was to use a 3D MRI technique to evaluate the topography of the proximal tibia and outline considerations in tibial component design for bicruciate-retaining TKA. We identified 100 consecutive patients (50 males and 50 females) between ages 20 and 40 years with knee MRIs without arthritis, dysplasia, ACL tears, or prior knee surgery. A novel 3D MRI protocol coordinating axial, coronal, and sagittal images was used to measure: 1) medial and lateral posterior tibial slopes; 2) medial and lateral coronal slopes; and 3) distance from the anterior tibia to the ACL footprint. There was no overall difference in medial and lateral posterior tibial slopes (5.5° (95% CI 5.0 to 6.0°) vs. 5.4° (95% CI 4.8 to 6.0°), respectively (p=0.80)), but 41 patients had side-to-side differences greater than 3°. The medial coronal slope was greater than the lateral coronal slope (4.6° (95% CI 4.0 to 5.1°) vs. 3.3° (95% CI 2.9 to 3.7°), respectively (p<0.0001)). Females had less clearance between the anterior tibia and ACL footprint than males (10.8mm (95% CI 10.4 to 11.2mm) vs. 13.0mm (95% CI 12.5 to 13.5mm), respectively (p<0.0001)). Due to highly variable proximal tibial topography, a monoblock bicruciate-retaining tibial baseplate may not reproduce normal anatomy in all patients. Level IV - Anatomic research study. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Self-reported previous knee injury and low knee function increase knee injury risk in adolescent female football.

    PubMed

    Clausen, M B; Tang, L; Zebis, M K; Krustrup, P; Hölmich, P; Wedderkopp, N; Andersen, L L; Christensen, K B; Møller, M; Thorborg, K

    2016-08-01

    Knee injuries are common in adolescent female football. Self-reported previous knee injury and low Knee injury and Osteoarthritis Outcome Score (KOOS) are proposed to predict future knee injuries, but evidence regarding this in adolescent female football is scarce. The aim of this study was to investigate self-reported previous knee injury and low KOOS subscale score as risk factors for future knee injuries in adolescent female football. A sample of 326 adolescent female football players, aged 15-18, without knee injury at baseline, were included. Data on self-reported previous knee injury and KOOS questionnaires were collected at baseline. Time-loss knee injuries and football exposures were reported weekly by answers to standardized text-message questions, followed by injury telephone interviews. A priori, self-reported previous knee injury and low KOOS subscale scores (< 80 points) were chosen as independent variables in the risk factor analyses. The study showed that self-reported previous knee injury significantly increased the risk of time-loss knee injury [relative risk (RR): 3.65, 95% confidence (CI) 1.73-7.68; P < 0.001]. Risk of time-loss knee injury was also significantly increased in players with low KOOS subscale scores (< 80 points) in Activities of Daily Living (RR: 5.0), Sport/Recreational (RR: 2.2) and Quality of Life (RR: 3.0) (P < 0.05). In conclusion, self-reported previous knee injury and low scores in three KOOS subscales significantly increase the risk of future time-loss knee injury in adolescent female football. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Microstructural modifications induced by accelerated aging and lipid absorption in remelted and annealed UHMWPEs for total hip arthroplasty

    PubMed Central

    Puppulin, Leonardo; Zhu, Wenliang; Sugano, Nobuhiko

    2014-01-01

    Three types of commercially available ultra-high molecular weight polyethylene (UHMWPE) acetabular cups currently used in total hip arthroplasty have been studied by means of Raman micro-spectroscopy to unfold the microstructural modification induced by the oxidative degradation after accelerated aging with and without lipid absorption. The three investigated materials were produced by three different manufacturing procedures, as follows: irradiation followed by remelting, one-step irradiation followed by annealing, 3-step irradiation and annealing. Clear microstructural differences were observed in terms of phase contents (i.e. amorphous, crystalline and intermediate phase fraction). The three-step annealed material showed the highest crystallinity fraction in the bulk, while the remelted polyethylene is clearly characterized by the lowest content of crystalline phase and the highest content of amorphous phase. After accelerated aging either with or without lipids, the amount of amorphous phase decreased in all the samples as a consequence of the oxidation-induced recrystallization. The most remarkable variations of phase contents were detected in the remelted and in the single-step annealed materials. The presence of lipids triggered oxidative degradation especially in the remelted polyethylene. Such experimental evidence might be explained by the highest amount of amorphous phase in which lipids can be absorbed prior to accelerated aging. The results of these spectroscopic characterizations help to rationalize the complex effect of different irradiation and post-irradiation treatments on the UHMWPE microstructure and gives useful information on how significantly any single step of the manufacturing procedures might affect the oxidative degradation of the polymer. PMID:25179830

  3. Early outcomes of twin-peg mobile-bearing unicompartmental knee arthroplasty compared with primary total knee arthroplasty.

    PubMed

    Lum, Z C; Lombardi, A V; Hurst, J M; Morris, M J; Adams, J B; Berend, K R

    2016-10-01

    Since redesign of the Oxford phase III mobile-bearing unicompartmental knee arthroplasty (UKA) femoral component to a twin-peg design, there has not been a direct comparison to total knee arthroplasty (TKA). Thus, we explored differences between the two cohorts. A total of 168 patients (201 knees) underwent medial UKA with the Oxford Partial Knee Twin-Peg. These patients were compared with a randomly selected group of 177 patients (189 knees) with primary Vanguard TKA. Patient demographics, Knee Society (KS) scores and range of movement (ROM) were compared between the two cohorts. Additionally, revision, re-operation and manipulation under anaesthesia rates were analysed. The mean follow-up for UKA and TKA groups was 5.4 and 5.5 years, respectively. Six TKA (3.2%) versus three UKAs (1.5%) were revised which was not significant (p = 0.269). Manipulation was more frequent after TKA (16; 8.5%) versus none in the UKA group (p < 0.001). UKA patients had higher post-operative KS function scores versus TKA patients (78 versus 66, p < 0.001) with a trend toward greater improvement, but there was no difference in ROM and KS clinical improvement (p = 0.382 and 0.420, respectively). We found fewer manipulations, and higher functional outcomes for patients treated with medial mobile-bearing UKA compared with TKA. TKA had twice the revision rate as UKA although this did not reach statistical significance with the numbers available. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):28-33. ©2016 Berend et al.

  4. Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation.

    PubMed

    Harman, Melinda K; Schmitt, Sabine; Rössing, Sven; Banks, Scott A; Sharf, Hans-Peter; Viceconti, Marco; Hodge, W Andrew

    2010-07-01

    Deviations from nominal alignment of unicondylar knee replacements impact knee biomechanics, including the load and stress distribution at the articular contact surfaces. This study characterizes relationships between the biomechanical environment, distinguished by progressive changes in alignment and fixation, and articular damage and deformation in a consecutive series of retrieved unicondylar knee replacements. Twenty seven fixed-bearing, non-conforming unicondylar knee replacements of one design were retrieved after 2 to 13 years of in vivo function. The in vivo biomechanical environment was characterized by grading component migration measured from full-length radiographs and grading component fixation based on intraoperative manual palpation. Articular damage patterns and linear deformation on the polyethylene inserts were measured using optical photogrammetry and contact point digitization. Articular damage patterns and surface deformation on the explanted polyethylene inserts corresponded to progressive changes in component alignment and fixation. Component migration produced higher deformation rates, whereas loosening contributed to larger damage areas but lower deformation rates. Migration and loosening of the femoral component, but not the tibial component, were factors contributing to large regions of abrasion concentrated on the articular periphery. Classifying component migration and fixation at revision proved useful for distinguishing common biomechanical conditions associated with the varied polyethylene damage patterns and linear deformation for this fixed-bearing, non-conforming design. Pre-clinical evaluations of unicondylar knee replacements that are capable of reproducing variations in clinical alignment and predicting the observed wear mechanisms are necessary to better understand the impact of knee biomechanics and design on unicondylar knee replacement longevity. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  5. Knee arthrodesis.

    PubMed

    MacDonald, James H; Agarwal, Sanjeev; Lorei, Matthew P; Johanson, Norman A; Freiberg, Andrew A

    2006-03-01

    Arthrodesis is one of the last options available to obtain a stable, painless knee in a patient with a damaged knee joint that is not amenable to reconstructive measures. Common indications for knee arthrodesis include failed total knee arthroplasty, periarticular tumor, posttraumatic arthritis, and chronic sepsis. The primary contraindications to knee fusion are bilateral involvement or an ipsilateral hip arthrodesis. A variety of techniques has been described, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Allograft or autograft may be necessary to restore lost bone stock or to augment fusion. For the carefully selected patient with realistic expectations, knee arthrodesis may relieve pain and obviate the need for additional surgery or extensive postoperative rehabilitation.

  6. A randomised controlled trial of the clinical effectiveness and cost-effectiveness of different knee prostheses: the Knee Arthroplasty Trial (KAT).

    PubMed

    Murray, David W; MacLennan, Graeme S; Breeman, Suzanne; Dakin, Helen A; Johnston, Linda; Campbell, Marion K; Gray, Alastair M; Fiddian, Nick; Fitzpatrick, Ray; Morris, Richard W; Grant, Adrian M

    2014-03-01

    In the late 1990s, new developments in knee replacement were identified as a priority for research within the NHS. The newer forms of arthroplasty were more expensive and information was needed on their safety and cost-effectiveness. The Knee Arthroplasty Trial examined the clinical effectiveness and cost-effectiveness of four aspects of knee replacement surgery: patellar resurfacing, mobile bearings, all-polyethylene tibial components and unicompartmental replacement. This study comprised a partial factorial, pragmatic, multicentre randomised controlled trial with a trial-based cost-utility analysis which was conducted from the perspective of the NHS and the patients treated. Allocation was computer generated in a 1 : 1 ratio using a central system, stratified by eligible comparisons and surgeon, minimised by participant age, gender and site of disease. Surgeons were not blinded to allocated procedures. Participants were unblinded if they requested to know the prosthesis they received. The setting for the trial was UK secondary care. Patients were eligible for inclusion if a decision had been made for them to have primary knee replacement surgery. Patients were recruited to comparisons for which the surgeon was in equipoise about which type of operation was most suitable. Patients were randomised to receive a knee replacement with the following: patellar resurfacing or no patellar resurfacing irrespective of the design of the prosthesis used; a mobile bearing between the tibial and femoral components or a bearing fixed to the tibial component; a tibial component made of either only high-density polyethylene ('all polyethylene') or a polyethylene bearing fixed to a metal backing plate with attached stem; or unicompartmental or total knee replacement. The primary outcome was the Oxford Knee Score (OKS). Other outcomes were Short Form 12; EuroQol 5D; intraoperative and postoperative complications; additional surgery; cost; and cost-effectiveness. Patients were

  7. Fixed or mobile-bearing total knee arthroplasty

    PubMed Central

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-01

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing. PMID:17204165

  8. Fixed or mobile-bearing total knee arthroplasty.

    PubMed

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-05

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.

  9. Self-Reported Knee Instability Before and After Total Knee Replacement Surgery.

    PubMed

    Fleeton, Genevieve; Harmer, Alison R; Nairn, Lillias; Crosbie, Jack; March, Lyn; Crawford, Ross; van der Esch, Martin; Fransen, Marlene

    2016-04-01

    To determine the prevalence and burden of pain and activity limitations associated with retaining presurgery self-reported knee instability 6 months after total knee replacement (TKR) surgery and to identify early potentially modifiable risk factors for retaining knee instability in the operated knee after TKR surgery. A secondary analysis was performed using measures obtained from 390 participants undergoing primary unilateral TKR and participating in a randomized clinical trial. Self-reported knee instability was measured using 2 items from the Activities of Daily Living Scale of the Knee Outcome Survey. Outcome measures were knee pain (range 0-20) and physical function (range 0-68) on the Western Ontario and McMaster Universities Arthritis Index (WOMAC), stair-climb power, 50-foot walk time, knee range of motion, and isometric knee flexion and extension strength. In this study, 72% of participants reported knee instability just prior to surgery, with 32% retaining instability in the operated knee 6 months after surgery. Participants retaining operated knee instability had significantly more knee pain and activity limitations 6 months after surgery, with mean ± SD WOMAC scores of 4.8 ± 3.7 and 17.5 ± 11.1, respectively, compared to participants without knee instability, with 2.9 ± 3.1 and 9.8 ± 9.2. The multivariable predictor model for retained knee instability included a high comorbidity score (>6), low stair-climb power (<150 watts), more pain in the operated knee (>7 of 20), and younger age (<60 years). Self-reported knee instability is highly prevalent before and after TKR surgery and is associated with a considerable burden of pain and activity limitation in the operated knee. Increasing lower extremity muscle power may reduce the risk of retaining knee instability after TKR surgery. © 2016, American College of Rheumatology.

  10. Two-Stage Revision for Infected Total Knee Arthroplasty: Based on Autoclaving the Recycled Femoral Component and Intraoperative Molding Using Antibiotic-Impregnated Cement on the Tibial Side.

    PubMed

    Lee, Byoung-Joo; Kyung, Hee-Soo; Yoon, Seong-Dae

    2015-09-01

    The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. The mean range of knee joint motion was 70° prior to the first stage operation and 72° prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113° at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.

  11. Hip and knee replacement in osteogenesis imperfecta.

    PubMed

    Papagelopoulos, P J; Morrey, B F

    1993-04-01

    Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.

  12. 49 CFR 572.166 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Knees and knee impact test procedure. 572.166... Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.166 Knees and knee impact test procedure. The knee assembly is assembled and tested as specified in 49 CFR 572.126 (Subpart N). ...

  13. Impingement of the Mobile Bearing on the Lateral Wall of the Tibial Tray in Unicompartmental Knee Arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Shirakawa, Nobuyuki; Tanaka, Sakae

    2016-07-01

    Tilting of the mobile bearing relative to the tibial tray in the flexion position may result from the implantation of femoral components more laterally relative to tibial components during unicompartmental knee arthroplasty (UKA) using the Oxford Knee. The purpose of the present study was to compare femoral component positions after UKA using the phase 3 device and a novel device. We further evaluated the placement of the femoral components with the new device in the flexion position to determine the association with short-term prognosis. The location of femoral and tibial components in the flexion position of 38 knees implanted using the phase 3 device and 49 knees using a novel device was assessed at 1 year postoperatively using radiography of the proximal tibia and distal femur in the flexion position. The femoral component was implanted more laterally using the new device than using the phase 3 device in the flexion position (P = .012), which caused the impingement of the mobile bearing against the lateral wall of the tibial tray. After UKA using the new device, 10% of patients exhibited the tilting phenomenon of the mobile bearing because of the lateral implantation of the femoral implant. To prevent implantation of the femoral component too laterally using the new device during UKA, knee surgeons should set the drill guide more medially such that the center of the drill is aligned with the middle of the medial femoral condyle. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Quality of outcome data in knee arthroplasty

    PubMed Central

    Pabinger, Christof; Lumenta, David Benjamin; Cupak, Daniel; Berghold, Andrea; Boehler, Nikolaus; Labek, Gerold

    2015-01-01

    Background and purpose Recent reports on developer bias in unicondylar knee arthroplasty led to concerns about quality of publications regarding knee implants. We therefore compared revision rates of registry and non-registry studies from the beginning of knee arthroplasty up to the present. We assessed the time interval between market introduction of an implant and emergence of reliable data in non-registry studies. Material and methods We systematically reviewed registry studies (n = 6) and non-registry studies (n = 241) on knee arthroplasty published in indexed, peer-reviewed international scientific journals. The main outcome measure was revision rate per 100 observed component years. Results and interpretation For 82% of the 34 knee implants assessed, revision data from non-registry studies are either absent or poor. 91% of all studies were published in the second and third decade after market introduction. Only 5% of all studies and 1% of all revisions were published in the first decade. The first publications on revision rates of total knee arthroplasty (TKA) started 6 years after market introduction, and reliable data were found from year 12 onward in non-registry studies. However, in unicondylar knee arthroplasty (UKA) the first publications on revision rates could be found first 13 years after market introduction. Revision rates of TKA from non-registry studies were reliable after year 12 following market introduction. UKA revision rates remained below the threshold of registry indices, and failed to demonstrate adjustment towards registries. Thus, the superiority of registry data over non-registry data regarding outcome measurement was validated. PMID:25191934

  15. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.

    2016-01-01

    Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763

  16. Patient specific guides for total knee arthroplasty are ready for primetime

    PubMed Central

    Schotanus, Martijn GM; Boonen, Bert; Kort, Nanne P

    2016-01-01

    AIM: To present the radiological results of total knee arthroplasty (TKA) with use of patient specific matched guides (PSG) from different manufacturer in patients suffering from severe osteoarthritis of the knee joint. METHODS: This study describes the results of 57 knees operated with 4 different PSG systems and a group operated with conventional instrumentation (n = 60) by a single surgeon. The PSG systems were compared with each other and subdivided into cut- and pin PSG. The biomechanical axis [hip-knee-ankle angle (HKA)], varus/valgus of the femur [frontal femoral component (FFC)] and tibia (frontal tibial component) component, flexion/extension of the femur [flexion/extension of the femur component (LFC)] and posterior slope of the tibia [lateral tibial component (LTC)] component were evaluated on long-leg standing and lateral X-rays. A percentage of > 3° deviation was seen as an outlier. RESULTS: The inter class correlation coefficient (ICC) revealed that radiographic measurements between both assessors were reliable (ICC > 0.8). Fisher exact test was used to test differences of proportions. The percentage of outliers of the HKA-axis was comparable between both the PSG and conventional groups (12.28% vs 18.33%, P < 0.424) and the cut- and pin PSG groups (14.3% vs 10.3%, P < 1.00). The percentage of outliers of the FFC (0% vs 18.33%, P < 0.000), LFC (15.78% vs 58.33%, P < 0.000) and LTC (15.78% vs 41.67%, P < 0.033) were significant different in favour of the PSG group. There were no significant differences regarding the outliers between the individual PSG systems and the PSG group subdivided into cut- and pin PSG. CONCLUSION: PSG for TKA show significant less outliers compared to the conventional technique. These single surgeon results suggest that PSG are ready for primetime. PMID:26807358

  17. Estimating patient-specific soft-tissue properties in a TKA knee.

    PubMed

    Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A

    2016-03-01

    Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Knee extension range of motion and self-report physical function in total knee arthroplasty: mediating effects of knee extensor strength

    PubMed Central

    2013-01-01

    Background Knee extensor strength and knee extension range of motion (ROM) are important predictors of physical function in patients with a total knee arthroplasty (TKA). However, the relationship between the two knee measures remains unclear. The purpose of this study was to examine whether changes in knee extensor strength mediate the association between changes in knee extension ROM and self-report physical function. Methods Data from 441 patients with a TKA were collected preoperatively and 6 months postoperatively. Self-report measure of physical function was assessed by the Short Form 36 (SF-36) questionnaire. Knee extensor strength was measured by handheld dynamometry and knee extension ROM by goniometry. A bootstrapped cross product of coefficients approach was used to evaluate mediation effects. Results Mediation analyses, adjusted for clinicodemographic measures, revealed that the association between changes in knee extension ROM and SF-36 physical function was mediated by changes in knee extensor strength. Conclusions In patients with TKA, knee extensor strength mediated the influence of knee extension ROM on physical function. These results suggest that interventions to improve the range of knee extension may be useful in improving knee extensor performance. PMID:23332039

  19. Cemented tibial component fixation performs better than cementless fixation: a randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years.

    PubMed

    Carlsson, Ake; Björkman, Anders; Besjakov, Jack; Onsten, Ingemar

    2005-06-01

    The question whether the tibial component of a total knee arthroplasty should be fixed to bone with or without bone cement has not yet been definitely answered. We studied movements between the tibial component and bone by radiostereometry (RSA) in total knee replacement (TKR) for 3 different types of fixation: cemented fixation (C-F), uncemented porous fixation (UC-F) and uncemented porous hydroxyapatite fixation (UCHA-F). 116 patients with osteoarthrosis, who had 146 TKRs, were included in 2 randomized series. The first series included 86 unilateral TKRs stratified into 1 of the 3 types of fixation. The second series included 30 patients who had simultaneous bilateral TKR surgery, and who were stratified into 3 subgroups of pairwise comparisons of the 3 types of fixation. After 5 years 2 knees had been revised, neither of which were due to loosening. 1 UCHA-F knee in the unilateral series showed a large and continuous migration and a poor clinical result, and is a pending failure. The C-F knees rotated and migrated less than UC-F and UCHA-F knees over 5 years. UCHA-F migrated less than UC-F after 1 year. Cementing of the tibial component offers more stable bone-implant contact for 5 years compared to uncemented fixation. When using uncemented components, however, there is evidence that augmenting a porous surface with hydroxyapatite may mean less motion between implant and bone after the initial postoperative year.

  20. Mobile-bearing knees reduce rotational asymmetric wear.

    PubMed

    Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung

    2007-09-01

    Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.

  1. [Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].

    PubMed

    Ren, J T; Xu, C; Wang, J S; Liu, X L

    2017-10-01

    Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the literature on PubMed, EMbase, Cochrane library, CBM and WanFang were searched. According to the inclusion and exclusion criteria, the high quality randomized control trial (RCT) studies about three-dimensional (3D) printing patient-specific instrumentation versus conventional instrumentation in the total knee arthroplasty were collected. The post-operative limb mechanical axis outlier, the position of the components outlier, post-operative knee function, operative time, post-operative blood transfusion and complications were analyzed by RevMan 5.3 software. Results: A total of 13 high quality RCT studies were included. The results of Meta-analysis show that there were no statistical differences in the post-operative limb mechanical axis outlier( Z =0.55, P =0.58, 95% CI: 0.78 to 1.56), femoral coronal component outlier( Z =0.38, P =0.71, 95% CI: 0.69 to 1.72), tibia coronal component outlier( Z =1.95, P =0.05, 95% CI: 1.00 to 3.38), femoral rotation angle outlier( Z =0.36, P =0.72, 95% CI: 0.49 to 1.64), post-operative knee function( Z =1.18, P =0.24, 95% CI : -0.66 to 2.63), post-operative blood transfusions( Z =0.74, P =0.46, 95% CI: -0.10 to 0.05) and complications( Z =0.18, P =0.86, 95% CI: -0.07 to 0.05) between the PSI group and the CI group. But there are statistical differences in the operation time( Z =2.66, P =0.01, 95% CI: -15.97 to -2.41)and tibia sagittal component outlier ( Z =3.69, P =0.00, 95% CI: 1.43 to 3.18)between the PSI group and the CI group. Conclusions: In the primary total knee arthroplasty the PSI is not superior over the CI for the knee without severe

  2. [Knee disarticulation and through-knee amputation].

    PubMed

    Baumgartner, R

    2011-10-01

    A knee disarticulation or a through-knee stump is superior compared to a transfemoral stump. The thigh muscles are all preserved, and the muscle balance remains undisturbed. The range of motion of the hip joint is not limited. The bulbous shape of the stump allows full weight bearing at the stump end and can easily be fitted with a prosthesis. An amputee with a bilateral knee disarticulation is able to walk "barefoot". A more distal amputation level, e.g., an ultra-short transtibial amputation, is not possible. Important alternative to transfemoral amputations. Possible for any etiology except for Buerger-Winiwarter's disease. New indications are infected and loosened total knee replacements. Preservation of the knee joint is possible. Knee disarticulation is a very atraumatic procedure, compared to transfemoral amputations. Neither bones nor muscles have to be severed, just skin, ligaments, vessels, and nerves. Even the meniscal cartilages may be left in place to act as axial shock absorbers. The cartilage of the femur is not resected, but only bevelled in case of osteoarthritis. There are no tendon attachments or myoplastic procedures necessary. The patella remains in place and is held in position only by the retinacula. Skin closure must be performed without the slightest tension, and if possible not in the weight-bearing area. Transcondylar amputations across the femoral condyles only are indicated when there are not sufficient soft tissues for wound closure of a knee disarticulation. Alternatives as the techniques of Gritti, Klaes, and Eigler, the shortening of the femur and the Sauerbruch's rotation plasty [14] are presented and discussed. The risk of decubital ulcers is rather high. Correct bandaging of the stump is, therefore, particularly important. Prosthetic fitting is possible 3-6 weeks after surgery. The type of prosthesis depends on the amputee's activity level. The superior performance of amputees with knee disarticulations in sports prove the

  3. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Modeling knee joint endoprosthesis mode of deformation

    NASA Astrophysics Data System (ADS)

    Skeeba, V. Yu; Ivancivsky, V. V.

    2018-03-01

    The purpose of the work was to define the efficient design of the endoprosthesis, working in a multiple-cycle loading environment. Methodology and methods: triangulated surfaces of the base contact surfaces of endoprosthesis butt elements have been created using the PowerShape and SolidWorks software functional environment, and the assemblies of the possible combinations of the knee joint prosthetic designs have been prepared. The mode of deformation modeling took place in the multipurpose program complex ANSYS. Results and discussion: as a result of the numerical modeling, the following data were obtained for each of the developed knee joint versions: the distribution fields of absolute (total) and relative deformations; equivalent stress distribution fields; fatigue strength coefficient distribution fields. In the course of the studies, the following efficient design assembly has been established: 1) Ti-Al-V alloy composite femoral component with polymer inserts; 2) ceramic liners of the compound separator; 3) a Ti-Al-V alloy composite tibial component. The fatigue strength coefficient for the femoral component is 4.2; for the femoral component polymer inserts is 1.2; for the ceramic liners of the compound separator is 3.1; for the tibial component is 2.7. This promising endoprosthesis structure is recommended for further design and technological development.

  5. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants

    PubMed Central

    2013-01-01

    Background Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices. PMID:23988155

  6. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.

    PubMed

    Turger, Anke; Köhler, Jens; Denkena, Berend; Correa, Tomas A; Becher, Christoph; Hurschler, Christof

    2013-08-29

    Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

  7. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...

  8. Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement?

    PubMed

    Luyckx, T; Peeters, T; Vandenneucker, H; Victor, J; Bellemans, J

    2012-09-01

    Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an 'adapted' measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (SD 2.5) in the gap-balancing group and 1.7° (SD 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our 'adapted' measured resection technique was much lower than reported in the literature.

  9. Combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction in knees with osteoarthritis and deficient anterior cruciate ligament.

    PubMed

    Tian, Shaoqi; Wang, Bin; Wang, Yuanhe; Ha, Chengzhi; Liu, Lun; Sun, Kang

    2016-08-05

    Relative young and more active patients with osteoarthritis (OA) of the isolated medial femorotibial compartment in conjunction with anterior cruciate ligament (ACL) deficiency are difficult to treat. The aim of this study was to explore the early clinical outcomes of combined Oxford unicompartmental knee arthroplasty (UKA) and ACL reconstruction for the patients presenting ACL deficiency and isolated OA of the medial compartment. Twenty-eight patients were included into the study. All patients were treated by combined Oxford UKA and ACL reconstruction. Plain radiographs in the antero-posterior and lateral view and long-leg standing radiographs were routinely performed prior to and after surgery. Stress radiographs in valgus were additionally available in order to verify the well-preserved lateral compartment. The varus deformity of the knee prior to surgery and the valgus degree after surgery, the posterior slope of the tibial component and the range of motion (ROM) of the knee after surgery were measured and recorded. Clinical evaluations include Oxford Knee Score (OKS), Knee Society Score (KSS-clinical score; KSS-function score) and Tegner activity score. All the patients were followed up for 52 ± 8 months. The leg alignment showed 3.1 ± 0.6° of varus deformity prior to surgery and 4.0 ± 0.7° of valgus after surgery. The OKS, KSS and Tegner activity score improved significantly after surgery (P < 0.05). The mean ROM of the operated knee was 123.5 ± 2.8° at the last follow-up. The posterior slope of the tibial component was 3.9 ± 1.2°. A significant correlation was found between them according to the Pearson's correlation (r = 0.39, P = 0.03). There were 2 patients (7 %) with the complication of mobile bearing dislocation, and a second operation of replacing a thicker mobile bearing was performed for them. The early clinical data have shown that combined surgery of UKA and ACL reconstruction has revealed promising

  10. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty

    PubMed Central

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-01-01

    Abstract Background: This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Methods: Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. Results: The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (−0.09 mm, 95% confidence interval [CI]: −0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: −1.01 to −0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. Conclusion: The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal

  11. 3D templating and patient-specific cutting guides (Knee-Plan) in total knee arthroplasty: postoperative CT-based assessment of implant positioning.

    PubMed

    Franceschi, J-P; Sbihi, A

    2014-10-01

    The precision of bone cuts and the positioning of components influence the functionality and longevity of total knee arthroplasty (TKA). The objective of this study was to evaluate the results of TKA, performed after 3D preoperative templating, with the prosthesis implanted using custom cutting guides (Knee-Plan system, Symbios Orthopédie SA). This prospective study investigated 107 TKAs. Three-dimensional preoperative templating was carried out on the surface views and CT views to analyze the deformation of the lower limb and plan the implantation. The components were positioned in an individualized manner to realign the lower limb and provide ligament balance based on bone landmarks. Final component positioning was analyzed in the three planes with a postoperative CT scan. The preoperative and 1 year follow-up IKS and WOMAC scores were collected and compared. All the cutting guides were stable and functional. Femoral component planning was reproduced with 0 ± 2 precision in the frontal plane (94%± 3), 2 ± 3 in the sagittal plane, and 0 ± 2 in the transverse plane. The precision of the tibial component was reproduced with 0 ± 2 precision in the frontal plane (93%± 3) and 0 ± 4 in the sagittal plane. The HKA angle increased from 177 ± 7 preoperatively to 180 ± 3 at 1 year of follow-up. The IKS and WOMAC scores were significantly improved at 1 year (P<0.0001). The Knee-Plan system can be a realistic, simple, and reliable alternative to conventional cutting guides and to computer-assisted surgery for TKA implantation. IV; prospective cohort study. Copyright © 2014. Published by Elsevier Masson SAS.

  12. Static knee alignment and its association with radiographic knee osteoarthritis.

    PubMed

    Teichtahl, A J; Cicuttini, F M; Janakiramanan, N; Davis, S R; Wluka, A E

    2006-09-01

    Although knee alignment is associated with the progression of knee osteoarthritis (OA), it is unclear which features that characterize radiographic OA are related to alignment. The aim of this study was to examine the relationship between static knee joint alignment (measured as a continuous variable) and the radiographic features of knee OA (joint space narrowing and osteophytes). One hundred and twenty one adults with symptomatic knee OA were recruited using a combined strategy including referral from specialist centres, arthritis support groups and media advertising. X-rays were performed to classify the severity of disease and to determine static knee alignment. Increasing varus knee alignment was associated with increasing risk of medial compartment joint space narrowing (P < 0.001) and osteophytes (P = 0.005). Increasing valgus knee alignment was associated with an increased risk for lateral compartment joint space narrowing (P < 0.001) and osteophytes (P = 0.002). This study has demonstrated that the static knee angle, measured as a continuous variable, is an important determinant of the compartment-specific features of radiographic knee OA. Further work is required to determine whether interventions aimed at correcting these relatively minor levels of varus and valgus angulation will have an effect on the risk of tibiofemoral OA.

  13. Validation of the Chinese (Mandarin) Version of the Oxford Knee Score in Patients with Knee Osteoarthritis.

    PubMed

    Lin, Kai; Bao, Liangxiao; Wang, Jian; Fujita, Kimie; Makimoto, Kiyoko; Liao, Xiaoyan

    2017-12-01

    's rank correlation coefficient to quantify the correlations between the OKS-CV and the WOMAC, Short Form-8 Health Survey (SF-8 TM ), and EuroQol Group 5-Dimension Self-Report Questionnaire (EQ-5D). Exploratory factor analysis was performed to clarify dimensionality. The eigenvalue indicates the importance of each factor obtained from factor analysis. Responsiveness was determined by standardized response mean (SRM) and effect size (ES) from preoperative and postoperative scores of the OKS-CV. Floor and ceiling effects also were analyzed. The internal consistency (Cronbach's alpha = 0.89) and test-retest reliability (ICC = 0.93; 95% CI, 0.87-0.97) proved good. Convergent construct validity was supported by moderate to strong correlations between the OKS-CV and the WOMAC (r = -0.80, p < 0.001), the SF-8 TM physical component summary (r = 0.65, p < 0.001), and the EQ-5D usual activities (r = -0.41, p < 0.001) and mobility (r = -0.35, p < 0.001). There also were correlations between the OKS-CV and the SF-8 TM mental component summary (r = 0.58, p < 0.001) and the EQ-5D anxiety/depression (r = -0.35, p < 0.001). The factor analysis yielded three factors with eigenvalues greater than 1. Responsiveness was excellent (SRM = 1.52; ES = 1.52). No floor or ceiling effect was observed. The OKS-CV showed good acceptability and psychometric properties for the intended population. Future studies are needed to evaluate the mental state of patients with knee osteoarthritis. The OKS-CV appears to be a reliable, valid, and responsive instrument for Chinese patients with knee osteoarthritis. Based on these results we believe the OKS-CV can be used as a valuable tool for the assessment of patient-reported outcomes in Chinese patients with knee osteoarthritis before and after TKA.

  14. Medial unicondylar knee arthroplasty combined to anterior cruciate ligament reconstruction.

    PubMed

    Ventura, Alberto; Legnani, Claudio; Terzaghi, Clara; Iori, Stefano; Borgo, Enrico

    2017-03-01

    The purpose of the present study was to retrospectively evaluate the outcomes of patients who underwent combined medial unicompartmental knee arthroplasty (UKA) and anterior cruciate ligament (ACL) reconstruction. The hypothesis was that this procedure would lead to a high success rate in patients affected by isolated medial unicompartmental osteoarthritis and concomitant ACL deficiency. Fourteen patients with primary ACL lesion and concomitant medial compartment symptomatic osteoarthritis treated from 2006 to 2010 were followed up for an average time of 26.7 months (SD 4.2). Assessment included KOOS score, Oxford Knee score, American Knee Society scores, WOMAC index of osteoarthritis, Tegner activity level and objective examination including instrumented laxity test with KT-1000 arthrometer. Radiological assessment was done with standard simple radiographs in order to get information about any presence of loosening of the components. KOOS score, OKS, WOMAC index and the AKSS improved significantly after surgery (p < 0.001). Regarding AKSS, improvement was noted both in the objective score and in the functional one (p < 0.001). There was no clinical evidence of instability in any of the knees as evaluated with clinical laxity testing. No pathologic radiolucent lines were observed around the components. In one patient signs of osteoarthritis in the lateral compartment were observed 28 months after surgery. UKA combined with ACL reconstruction is a valid therapeutic option for the treatment of combined medial unicompartmental knee osteoarthritis and ACL deficiency in young and active patients and confirms subjective and objective clinical improvement 2 years after surgery. The use of a fixed-bearing prosthesis represents a reliable feature as it allows to overcome problems of improper ligament tensioning during the implantation of the components. IV.

  15. Knee MRI scan

    MedlinePlus

    ... CT scan of the knee Knee x-ray Alternative Names MRI - knee; Magnetic resonance imaging - knee Patient ... any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should ...

  16. Association of knee confidence with pain, knee instability, muscle strength, and dynamic varus-valgus joint motion in knee osteoarthritis.

    PubMed

    Skou, Søren T; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Bennell, Kim L

    2014-05-01

    To investigate associations between self-reported knee confidence and pain, self-reported knee instability, muscle strength, and dynamic varus-valgus joint motion during walking. We performed a cross-sectional analysis of baseline data from 100 participants with symptomatic and radiographic medial tibiofemoral compartment osteoarthritis (OA) and varus malalignment recruited for a randomized controlled trial. The extent of knee confidence, assessed using a 5-point Likert scale item from the Knee Injury and Osteoarthritis Outcome Score, was set as the dependent variable in univariable and multivariable ordinal regression, with pain during walking, self-reported knee instability, quadriceps strength, and dynamic varus-valgus joint motion during walking as independent variables. One percent of the participants were not troubled with lack of knee confidence, 17% were mildly troubled, 50% were moderately troubled, 26% were severely troubled, and 6% were extremely troubled. Significant associations were found between worse knee confidence and higher pain intensity, worse self-reported knee instability, lower quadriceps strength, and greater dynamic varus-valgus joint motion. The multivariable model consisting of the same variables significantly accounted for 24% of the variance in knee confidence (P < 0.001). Worse knee confidence is associated with higher pain, worse self-reported knee instability, lower quadriceps muscle strength, and greater dynamic varus-valgus joint motion during walking. Since previous research has shown that worse knee confidence is predictive of functional decline in knee OA, addressing lack of knee confidence by treating these modifiable impairments could represent a new therapeutic target. Copyright © 2014 by the American College of Rheumatology.

  17. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment.

    PubMed

    Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F

    2009-12-01

    New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.

  18. Osteochondral microdamage from valgus bending of the human knee.

    PubMed

    Meyer, Eric G; Villwock, Mark R; Haut, Roger C

    2009-08-01

    Valgus bending of the knee is promoted as an anterior cruciate ligament injury mechanism and is associated with a characteristic "footprint" of bone bruising. The hypothesis of this study was that during ligamentous failure caused by valgus bending of the knee, high tibiofemoral contact pressures induce acute osteochondral microdamage. Four knee pairs were loaded in valgus bending until gross injury with or without a tibiofemoral compression pre-load. The peak valgus moment and resultant motions of the knee joint were recorded. Pressure sensitive film documented the magnitude and location of tibiofemoral contact. Cartilage fissures were documented on the tibial plateau, and microcracks in subchondral bone were documented from micro-computed tomography scans. Injuries were to the anterior cruciate ligament in three knees and the medial collateral ligament in seven knees. The mean (standard deviation) peak bending moment at failure was 107 (64)Nm. Valgus bending produced regions of contact on the lateral tibial plateau with average maximum pressures of approximately 30 (8)MPa. Cartilage fissures and subchondral bone microcracks were observed in these regions of high contact pressure. Combined valgus bending and tibiofemoral compression produce slightly higher contact pressures, but do not alter the gross injury pattern from isolated valgus bending experiments. Athletes who sustain a severe valgus knee bending moment, may be at risk of acute osteochondral damage especially if the loading mechanism occurs with a significant tibiofemoral compression component.

  19. The role of fixation and bone quality on the mechanical stability of tibial knee components.

    PubMed

    Lee, R W; Volz, R G; Sheridan, D C

    1991-12-01

    Tibial component loosening remains one of the major causes of failure of cemented and noncemented total knee arthroplasties. In this study, the authors identified the role of implant design, method of fixation, and bone density as it related to implant stability. The physical properties of "good" and "bad" bone were simulated using a "good" and "bad" foam model of the proximal tibia, fabricated in the laboratory from DARO RF-100 foam. A generic tibial component permitting various fixation designs was implanted into "good" and "bad" variable density foam tibial models in both cemented and noncemented modes. The mechanical stability of the implants was determined using a Materials Testing Machine by the application of an eccentrically applied cyclic load. The micromotion (subsidence and lift-off) of the tibial implants was recorded using two Linear Variable Differential Transformers. Statistically significant differences in implant stability were recorded as a function of fixation method. The most rigid implant fixation was achieved using four peripherally placed, 6.5-mm cancellous screws. The addition of a central stem added stability only in the case of "poor" quality foam. The mechanical stability of noncemented implants related directly to the density of the foam. Implant stability was greatly enhanced in "poor" quality foam by the use of cement. The method of implant fixation and bone density are critical determinants to tibial implant stability.

  20. 16S rRNA analysis provides evidence of biofilms on all components of three infected periprosthetic knees including permanent braided suture.

    PubMed

    Swearingen, Matthew C; DiBartola, Alex C; Dusane, Devendra; Granger, Jeffrey; Stoodley, Paul

    2016-10-01

    Bacterial biofilms are the main etiological agent of periprosthetic joint infections (PJI); however, it is unclear if biofilms colonize one or multiple components. Because biofilms can colonize a variety of surfaces, we hypothesized that biofilms would be present on all components. 16S ribosomal RNA (rRNA) gene sequencing analysis was used to identify bacteria recovered from individual components and non-absorbable suture material recovered from three PJI total knee revision cases. Bray-Curtis non-metric multidimensional scaling analysis revealed no significant differences in similarity when factoring component, material type, or suture versus non-suture material, but did reveal significant differences in organism profile between patients (P < 0.001) and negative controls (P < 0.001). Confocal microscopy and a novel agar encasement culturing method also confirmed biofilm growth on a subset of components. While 16S sequencing suggested that the microbiology was more complex than revealed by culture contaminating, bacterial DNA generates a risk of false positives. This report highlights that biofilm bacteria may colonize all infected prosthetic components including braided suture material, and provides further evidence that clinical culture can fail to sufficiently identify the full pathogen profile in PJI cases. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. The biological response to nanometre-sized polymer particles.

    PubMed

    Liu, Aiqin; Richards, Laura; Bladen, Catherine L; Ingham, Eileen; Fisher, John; Tipper, Joanne L

    2015-09-01

    Recently, nanometre-sized UHMWPE particles generated from hip and knee replacements have been identified in vitro and in vivo. UHMWPE particles in the 0.1-1.0μm size range have been shown to be more biologically active than larger particles, provoking an inflammatory response implicated in late aseptic loosening of total joint replacements. The biological activity of nanometre-sized particles has not previously been studied. The biological response to clinically-relevant UHMWPE wear particles including nanometre-sized and micrometre-sized, along with polystyrene particles (FluoSpheres 20nm, 60nm, 200nm and 1.0μm), and nanometre-sized model polyethylene particles (Ceridust 3615®), was determined in terms of osteolytic cytokine release from primary human peripheral blood mononuclear cells (PBMNCs). Nanometre-sized UHMWPE wear particles, nanometre-sized Ceridust 3615® and 20nm FluoSpheres had no significant effect on TNF-α, IL-1β, IL-6 and IL-8 release from PBMNCs at a concentration of 100μm(3) particles per cell after 12 and 24h. The micrometre-size UHMWPE wear particles (0.1-1.0μm) and 60nm, 200nm and 1.0μm FluoSpheres caused significantly elevated osteolytic cytokine release from PBMNCs. These results indicated that particles below circa 50nm fail to activate PBMNCs and that particle size, composition and morphology played a crucial role in cytokine release by particle stimulated macrophages. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. The biological response to nanometre-sized polymer particles

    PubMed Central

    Liu, Aiqin; Richards, Laura; Bladen, Catherine L.; Ingham, Eileen; Fisher, John; Tipper, Joanne L.

    2015-01-01

    Recently, nanometre-sized UHMWPE particles generated from hip and knee replacements have been identified in vitro and in vivo. UHMWPE particles in the 0.1–1.0 μm size range have been shown to be more biologically active than larger particles, provoking an inflammatory response implicated in late aseptic loosening of total joint replacements. The biological activity of nanometre-sized particles has not previously been studied. The biological response to clinically-relevant UHMWPE wear particles including nanometre-sized and micrometre-sized, along with polystyrene particles (FluoSpheres 20 nm, 60 nm, 200 nm and 1.0 μm), and nanometre-sized model polyethylene particles (Ceridust 3615®), was determined in terms of osteolytic cytokine release from primary human peripheral blood mononuclear cells (PBMNCs). Nanometre-sized UHMWPE wear particles, nanometre-sized Ceridust 3615® and 20 nm FluoSpheres had no significant effect on TNF-α, IL-1β, IL-6 and IL-8 release from PBMNCs at a concentration of 100 μm3 particles per cell after 12 and 24 h. The micrometre-size UHMWPE wear particles (0.1–1.0 μm) and 60 nm, 200 nm and 1.0 μm FluoSpheres caused significantly elevated osteolytic cytokine release from PBMNCs. These results indicated that particles below circa 50 nm fail to activate PBMNCs and that particle size, composition and morphology played a crucial role in cytokine release by particle stimulated macrophages. PMID:26004221

  3. Mobile-bearing knee systems: ultra-high molecular weight polyethylene wear and design issues.

    PubMed

    Greenwald, A Seth; Heim, Christine S

    2005-01-01

    In June 2004, the U.S. Food and Drug Administration Orthopaedic Advisory Panel recommended the reclassification of mobile-bearing knee systems for general use. This reflects the increasing use of mobile-bearing knee systems internationally, which is currently limited in the United States by regulatory requirement. Mobile-bearing knee systems are distinguished from conventional, fixed-plateau systems in that they allow dual-surface articulation between an ultra-high molecular weight polyethylene insert and metallic femoral and tibial tray components. Their in vivo success is dependent on patient selection, design, and material choice, as well as surgical precision during implantation. Laboratory and clinical experience extending over 25 years with individual systems suggests that mobile-bearing knee systems represent a viable treatment option for patients with knee arthrosis.

  4. [Total knee arthroplasty by lateral parapatellar approach for valgus knee].

    PubMed

    Zhou, Dian-ge; Zhang, Bin; Kou, Bo-long; Lü, Hou-shan

    2007-07-17

    To investigate the effect of lateral parapatellar approach in total knee arthroplasty (TKA) of valgus knee. Lateral parapatellar approach of total knee arthroplasty was applied in 8 patients (10 knees) with severe valgus osteoarthritis knee (bilateral in 2 cases and unilateral in 6 cases), with the valgus angle > 15 degrees , 1 male (1 knee) and 7 females (9 knee), aged 68.2 (58 - 79), 7 cases (9 knees) being of the Krackow type I and 1 case (1 knee) of the Krackow type I, I. After incision of the skin through lateral knee, ilio-tibial band was prolonged by apple pie arthroplasty. The joint capsule was cut open laterally 2 - 4 cm from the para-patellar edge. Soft tissue balance was performed by releasing I - T band in Gerdy tubercle, lateral collateral ligament and poster-lateral capsule from the femur and tibial side. Valgus angle of distal femur cutting were five degree. Whiteside line and trans-epicondylar line were used as AP rotational cutting reference. All patellar of the group were resurfaced. Capsule closure is completed with the knee flexed. The expanded deep lateral soft tissue sleeve (coronal Z-plasty) is sutured with the medial retinaculum sleeve (superficial layer). Follow-up was conducted for 19.6 months (1 - 51 months). Seven cases (9 knees) were replaced by posterior stabilized cemented prostheses (TC-Dynamic, PLUS), one case (1 knee) was replaced by RT prosthesis (RT-PLUS(TM) Solution, PLUS). After operation, the valgus deformity of all patients was corrected and all patients could walk 100 m with or without the help of walking holders. The average range of motion (ROM) was improved from the pre-operative. 95.6 degrees (85 degrees - 110 degrees ) to the post-operative 117.1 degrees (100 degrees - 125 degrees ). The average femorotibial angle (FTA) was corrected from the pre-operative. 27.6 degrees (20 degrees - 40 degrees ) to the post-operative 6.8 degrees (5 degrees - 9 degrees ). The Knee Score System (KSS) score and functional score were

  5. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  6. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  7. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

    PubMed

    Lee, Yong Seuk; Howell, Stephen M; Won, Ye-Yeon; Lee, O-Sung; Lee, Seung Hoon; Vahedi, Hamed; Teo, Seow Hui

    2017-11-01

    A systematic review was conducted to answer the following questions: (1) Does kinematically aligned (KA) total knee arthroplasty (TKA) achieve clinical outcomes comparable to those of mechanically aligned (MA) TKA? (2) How do the limb, knee, and component alignments differ between KA and MA TKA? (3) How is joint line orientation angle (JLOA) changed from the native knee in KA TKA compared to that in MA TKA? Nine full-text articles in English that reported the clinical and radiological outcomes of KA TKA were included. Five studies had a control group of patients who underwent MA TKA. Data on patient demographics, clinical scores, and radiological results were extracted. There were two level I, one level II, three level III, and three level IV studies. Six of the nine studies used patient-specific instrumentation, one study used computer navigation, and two studies used manual instrumentation. The clinical outcomes of KA TKA were comparable or superior to those of MA TKA with a minimum 2-year follow-up. Limb and knee alignment in KA TKA was similar to those in MA TKA, and component alignment showed slightly more varus in the tibial component and slightly more valgus in the femoral component. The JLOA in KA TKA was relatively parallel to the floor compared to that in the native knee and not oblique (medial side up and lateral side down) compared to that in MA TKA. The implant survivorship and complication rate of the KA TKA were similar to those of the MA TKA. Similar or better clinical outcomes were produced by using a KA TKA at early-term follow-up and the component alignment differed from that of MA TKA. KA TKA seemed to restore function without catastrophic failure regardless of the alignment category up to midterm follow-up. The JLOA in KA TKA was relatively parallel to the floor similar to the native knee compared to that in MA TKA. The present review of nine published studies suggests that relatively new kinematic alignment is an acceptable and alternative

  8. [Clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity].

    PubMed

    Chen, Peng; Zeng, Min; Xie, Jie; Wang, Long; Su, Weiping; Hu, Yihe

    2016-09-28

    To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
 A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect.
 Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (P<0.05). The clinical and function KSS scores showed that the improvement rate was 80%. 
 Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis

  9. Effect of knee joint angle on neuromuscular activation of the vastus intermedius muscle during isometric contraction.

    PubMed

    Watanabe, K; Akima, H

    2011-12-01

    The purpose of this study was to compare the relationship between surface electromyography (EMG) and knee joint angle of the vastus intermedius muscle (VI) with the synergistic muscles in the quadriceps femoris (QF) muscle group. Fourteen healthy men performed maximal voluntary contractions during isometric knee extension at four knee joint angles from 90°, 115°, 140°, and 165° (180° being full extension). During the contractions, surface EMG was recorded at four muscle components of the QF muscle group: the VI, vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) muscles. The root mean square of the surface EMG at each knee joint angle was calculated and normalized by that at a knee joint angle of 90° for individual muscles. The normalized RMS of the VI muscle was significantly lower than those of the VL and RF muscles at the knee joint angles of 115° and 165° and those of the VL, VM, and RF muscles at the knee joint angle of 140° (P<0.05). The present results suggest that the neuromuscular activation of the VI muscle is regulated in a manner different from the alteration of the knee joint angle compared with other muscle components of the QF muscle group. © 2011 John Wiley & Sons A/S.

  10. Metal Hypersensitivity and Total Knee Arthroplasty

    PubMed Central

    Lachiewicz, Paul F.; Watters, Tyler Steven; Jacobs, Joshua J.

    2015-01-01

    Metal hypersensitivity in patients with a total knee arthroplasty (TKA) is a controversial topic. The diagnosis is difficult, given the lack of robust clinical validation of the utility of cutaneous and in vitro testing. Metal hypersensitivity after TKA is quite rare and should be considered after eliminating other causes of pain and swelling, such as low-grade infection, instability, component loosening or malrotation, referred pain, and chronic regional pain syndrome. Anecdotal observations suggest that two clinical presentations of metal hypersensitivity may occur after TKA: dermatitis or a persistent painful synovitis of the knee. Patients may or may not have a history of intolerance to metal jewelry. Laboratory studies, including erythrocyte sedimentation rate, C-reactive protein level, and knee joint aspiration, are usually negative. Cutaneous and in vitro testing have been reported to be positive, but the sensitivity and specificity of such testing has not been defined. Anecdotal reports suggest that, if metal hypersensitivity is suspected and nonsurgical measures have failed, then revision to components fabricated of titanium alloy or zirconium coating can be successful in relieving symptoms. Revision should be considered as a last resort, however, and patients should be informed that no evidence-based medicine is available to guide the management of these conditions, particularly for decisions regarding revision. Given the limitations of current testing methods, the widespread screening of patients for metal allergies before TKA is not warranted. PMID:26752739

  11. [CORRECTION OF VARUS KNEE WITH REDUCTION OSTEOTOMY DURING TOTAL KNEE ARTHROPLASTY].

    PubMed

    Su, Weiping; Xie, Jie; Li, Mingqing; Zeng, Min; Lei, Pengfei; Wang, Long; Hu, Yihe

    2015-12-01

    To evaluate the effectiveness of reduction osteotomy for correction of varus knee during total knee arthroplasty. A retrospective analysis was made on the clinical data of 16 patients (24 knees) who received reduction osteotomy for correcting varus knee during total knee arthroplasty between May 2010 and July 2012. There were 2 males (3 knees) and 14 females (21 knees), with an average age of 67 years (range, 57-79 years). The disease duration ranged from 3 to 15 years (mean, 9.1 years). The Knee Society Score (KSS) was 38.71 ± 10.04 for clinical score and 50.31 ± 14.31 for functional score. The range of motion (ROM) of the knee was (91.88 ± 13.01). The tibiofemoral angle was (9.04 ± 4.53)° of varus deformity. Reduction osteotomy was applied to correct varus knee. The operation time was 85-245 minutes (mean, 165.5 minutes); the obvious blood loss was 10-800 mL (mean, 183.1 mL); the hospitalization time was 8-22 days (mean, 13.6 days). All incisions healed by first intention. No neurovascular injury or patellar fracture occurred. The follow-up duration ranged from 37 to 62 months (mean, 48 months). The tibiofemoral angle was corrected to (3.92 ± 1.89)° of valgus at 48 hours after operation. The lower limb alignment recovered to normal. The X-ray films showed no evidence of obvious radiolucent line, osteolysis, or prosthesis subsidence. The results of KSS were significantly improved to 84.21 ± 6.49 for clinical score and 85.31 ± 6.95 for functional score (t = 20.665, P = 0.000; t = 9.585, P = 0.000); and ROM of the knee was significantly increased to (105.83 ± 11.29)° (t = 8.333, P = 0.000) at last follow-up. The effectiveness of reduction osteotomy for varus knee deformity during total knee arthroplasty is satisfactory. Proper alignment, ROM, and function of knee can be achieved.

  12. Kinematic alignment technique for total hip and knee arthroplasty

    PubMed Central

    Rivière, Charles; Lazic, Stefan; Villet, Loïc; Wiart, Yann; Allwood, Sarah Muirhead; Cobb, Justin

    2018-01-01

    Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality. Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined. By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity. The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation. The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy. The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position. Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022 PMID:29657851

  13. Knee joint loading in knee osteoarthritis: influence of abdominal and thigh fat.

    PubMed

    Messier, Stephen P; Beavers, Daniel P; Loeser, Richard F; Carr, J Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J; Hunter, David J; Devita, Paul

    2014-09-01

    Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee joint loads in older overweight and obese adults with knee osteoarthritis (OA). Fat depots were quantified using computed tomography, and total lean and fat mass were determined with dual energy x-ray absorptiometry in 176 adults (age, 66.3 yr; body mass index, 33.5 kg·m) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Higher total body mass was significantly associated (P ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (P < 0.0001), patellofemoral forces (P < 0.006), and knee extensor moments (P = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (P = 0.0001), shear (P < 0.001), and patellofemoral forces (P = 0.01) and knee extension moment (P = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (P = 0.002). A regression model that included total thigh and total abdominal fat found that both were significantly associated with knee compressive and shear forces (P ≤ 0.04). Thigh fat was associated with knee abduction (P = 0.03) and knee extension moment (P = 0.02). Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA.

  14. Association of magnetic resonance imaging-based knee cartilage T2 measurements and focal knee lesions with knee pain: data from the Osteoarthritis Initiative.

    PubMed

    Baum, Thomas; Joseph, Gabby B; Arulanandan, Ahilan; Nardo, Lorenzo; Virayavanich, Warapat; Carballido-Gamio, Julio; Nevitt, Michael C; Lynch, John; McCulloch, Charles E; Link, Thomas M

    2012-02-01

    To evaluate the association of magnetic resonance imaging (MRI)-based knee cartilage T2 measurements and focal knee lesions with knee pain in knees without radiographic osteoarthritis (OA) among subjects with OA risk factors. We studied the right knees of 126 subjects from the Osteoarthritis Initiative database. We randomly selected 42 subjects ages 45-55 years with OA risk factors, right knee pain (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC] pain score ≥5), no left knee pain (WOMAC pain score 0), and no radiographic OA (Kellgren/Lawrence [K/L] score ≤1) in the right knee. We also selected 2 comparison groups: 42 subjects without knee pain in either knee and 42 with bilateral knee pain. Both groups were frequency matched to subjects with right knee pain only by sex, age, body mass index, and K/L score. All of the subjects underwent 3T MRI of the right knee. Focal knee lesions were assessed and cartilage T2 measurements were performed. Prevalences of meniscal, bone marrow, and ligamentous lesions and joint effusion were not significantly different between the groups (P > 0.05), while cartilage lesions were more frequent in subjects with right knee pain only compared to subjects without knee pain (P < 0.05). T2 values averaged over all of the compartments were similar in subjects with right knee pain only (mean ± SD 34.4 ± 1.8 msec) and in subjects with bilateral knee pain (mean ± SD 34.7 ± 4.7 msec), but were significantly higher compared to subjects without knee pain (mean ± SD 32.4 ± 1.8 msec; P < 0.05). These results suggest that elevated cartilage T2 values are associated with findings of pain in the early phase of OA, whereas among morphologic knee abnormalities only knee cartilage lesions are significantly associated with knee pain status. Copyright © 2012 by the American College of Rheumatology.

  15. Effects of Reduction Osteotomy on Gap Balancing During Total Knee Arthroplasty for Severe Varus Deformity.

    PubMed

    Niki, Yasuo; Harato, Kengo; Nagai, Katsuya; Suda, Yasunori; Nakamura, Masaya; Matsumoto, Morio

    2015-12-01

    This study aimed to assess the effects of down-sizing and lateralizing of the tibial component (reduction osteotomy) on gap balancing in TKA, and the clinical feasibility of an uncemented modular trabecular metal tibial tray in this technique. Reduction osteotomy was performed for 39 knees of 36 patients with knee OA with a mean tibiofemoral angle of 21° varus. In 20 knees, appropriate gap balance was achieved by release of the deep medial collateral ligament alone. Flexion gap imbalance could be reduced by approximately 1.7° and 2.8° for 4-mm osteotomy and 8-mm osteotomy, respectively. Within the first postoperative year, clinically-stable tibial component subsidence was observed in 9 knees, but it was not progressive, and the clinical results were excellent at a mean follow-up of 3.3 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Negative emotions affect postoperative scores for evaluating functional knee recovery and quality of life after total knee replacement.

    PubMed

    Qi, A; Lin, C; Zhou, A; Du, J; Jia, X; Sun, L; Zhang, G; Zhang, L; Liu, M

    2016-01-01

    This study aimed to determine whether psychological factors affect health-related quality of life (HRQL) and recovery of knee function in total knee replacement (TKR) patients. A total of 119 TKR patients (male: 38; female: 81) completed the Beck Anxiety Inventory (BAI), Beck Depression Inventory (BDI), State Trait Anxiety Inventory (STAI), Eysenck Personality Questionnaire-revised (EPQR-S), Knee Society Score (KSS), and HRQL (SF-36). At 1 and 6 months after surgery, anxiety, depression, and KSS scores in TKR patients were significantly better compared with those preoperatively (P<0.05). SF-36 scores at the sixth month after surgery were significantly improved compared with preoperative scores (P<0.001). Preoperative Physical Component Summary Scale (PCS) and Mental Component Summary Scale (MCS) scores were negatively associated with extraversion (E score) (B=-0.986 and -0.967, respectively, both P<0.05). Postoperative PCS and State Anxiety Inventory (SAI) scores were negatively associated with neuroticism (N score; B=-0.137 and -0.991, respectively, both P<0.05). Postoperative MCS, SAI, Trait Anxiety Inventory (TAI), and BAI scores were also negatively associated with the N score (B=-0.367, -0.107, -0.281, and -0.851, respectively, all P<0.05). The KSS function score at the sixth month after surgery was negatively associated with TAI and N scores (B=-0.315 and -0.532, respectively, both P<0.05), but positively associated with the E score (B=0.215, P<0.05). The postoperative KSS joint score was positively associated with postoperative PCS (B=0.356, P<0.05). In conclusion, for TKR patients, the scores used for evaluating recovery of knee function and HRQL after 6 months are inversely associated with the presence of negative emotions.

  17. Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.

    PubMed

    Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin

    2017-06-01

    Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P < .01). The average knee flexion improved from 105.6° preoperatively to 117.4° postoperatively (P < .01). Eight patients required subsequent implant revision. No cases of bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Improved knee biomechanics among patients reporting a good outcome in knee-related quality of life one year after total knee arthroplasty.

    PubMed

    Naili, Josefine E; Wretenberg, Per; Lindgren, Viktor; Iversen, Maura D; Hedström, Margareta; Broström, Eva W

    2017-03-21

    It is not well understood why one in five patients report poor outcomes following knee arthroplasty. This study evaluated changes in knee biomechanics, and perceived pain among patients reporting either a good or a poor outcome in knee-related quality of life after total knee arthroplasty. Twenty-eight patients (mean age 66 (SD 7) years) were included in this prospective study. Within one month of knee arthroplasty and one year after surgery, patients underwent three-dimensional (3D) gait analysis, completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), and rated perceived pain using a visual analogue scale. A "good outcome" was defined as a change greater than the minimally detectable change in the KOOS knee-related quality of life, and a "poor outcome" was defined as change below the minimally detectable change. Nineteen patients (68%) were classified as having a good outcome. Groups were analyzed separately and knee biomechanics were compared using a two-way repeated measures ANOVA. Differences in pain between groups were evaluated using Mann Whitney U test. Patients classified as having a good outcome improved significantly in most knee gait biomechanical outcomes including increased knee flexion-extension range, reduced peak varus angle, increased peak flexion moment, and reduced peak valgus moment. The good outcome group also displayed a significant increase in walking speed, a reduction (normalization) of stance phase duration (% of gait cycle) and increased passive knee extension. Whereas, the only change in knee biomechanics, one year after surgery, for patients classified as having a poor outcome was a significant reduction in peak varus angle. No differences in pain postoperatively were found between groups. Patients reporting a good outcome in knee-related quality of life improved in knee biomechanics during gait, while patients reporting a poor outcome, despite similar reduction in pain, remained unchanged in knee biomechanics one year after

  19. Varus Thrust and Knee Frontal Plane Dynamic Motion in Persons with Knee Osteoarthritis

    PubMed Central

    Chang, Alison H.; Chmiel, Joan S.; Moisio, Kirsten C.; Almagor, Orit; Zhang, Yunhui; Cahue, September; Sharma, Leena

    2013-01-01

    Objective Varus thrust visualized during walking is associated with a greater medial knee and an increased risk of medial knee osteoarthritis (OA) progression. Little is known about varus thrust presence determined by visual observation relates to quantitative gait kinematic We hypothesized that varus thrust presence is associated with greater knee frontal plane dynamic movement during the stance phase of gait. Methods Participants had knee OA in at least one knee. Trained examiners assessed participants for varus thrust presence during ambulation. Frontal plane knee motion during ambulation captured using external passive reflective markers and an 8-camera motion analysis system. To examine the cross-sectional relationship between varus thrust and frontal plane knee motion, used multivariable regression models with the quantitative motion measures as dependent variables and varus thrust (present/absent) as predictor; models were adjusted for age, gender, BMI, gait speed, and knee static alignment. Results 236 persons [mean BMI: 28.5 kg/m2 (SD 5.5), mean age: 64.9 years (SD 10.4), 75.8% women] contributing 440 knees comprised the study sample. 82 knees (18.6%) had definite varus thrust. Knees with varus thrust had greater peak varus angle and greater peak varus angular velocity during stance than knees without varus thrust (mean differences 0.90° and 6.65°/sec, respectively). These patterns remained significant after adjusting for age, gender, BMI, gait speed, and knee static alignment. Conclusion Visualized varus thrust during walking was associated with a greater peak knee varus angular velocity and a greater peak knee varus angle during stance phase of gait. PMID:23948980

  20. KNEE-JOINT LOADING IN KNEE OSTEOARTHRITIS: INFLUENCE OF ABDOMINAL AND THIGH FAT

    PubMed Central

    Messier, Stephen P.; Beavers, Daniel P.; Loeser, Richard F.; Carr, J. Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J.; Hunter, David J.; DeVita, Paul

    2014-01-01

    Purpose Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee-joint loads in older overweight and obese adults with knee osteoarthritis (OA). Methods Fat depots were quantified using computed tomography and total lean and fat mass determined with dual energy x-ray absorptiometry in 176 adults (age = 66.3 yr., BMI = 33.5 kg·m−2) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Results Higher total body mass was significantly associated (p ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (p < 0.0001), patellofemoral forces (p< 0.006), and knee extensor moments (p = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (p = 0.0001), shear (p < 0.001), and patellofemoral forces (p = 0.01) and knee extension moment (p = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (p = 0.002). A regression model that included total thigh and total abdominal fat found both were significantly associated with knee compressive and shear forces (p ≤ 0.04). Thigh fat was associated with the knee abduction (p = 0.03) and knee extension moment (p = 0.02). Conclusions Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA. PMID:25133996

  1. Knee Instability and Basic and Advanced Function Decline in Knee Osteoarthritis.

    PubMed

    Sharma, Leena; Chmiel, Joan S; Almagor, Orit; Moisio, Kirsten; Chang, Alison H; Belisle, Laura; Zhang, Yunhui; Hayes, Karen W

    2015-08-01

    Manifestations of instability in knee osteoarthritis (OA) include low overall knee confidence, low confidence that the knees will not buckle, buckling, and excessive motion during gait. Confidence and buckling may particularly influence activity choices, contributing to events leading to disability. Buckling is more likely to affect advanced than basic functional tasks. In this prospective longitudinal study, we tested the hypothesis that overall knee confidence, buckling confidence, buckling, and frontal plane motion during gait are associated with advanced 2-year function outcomes in persons with knee OA. Persons with knee OA were queried about overall knee confidence (higher score = worse confidence), buckling confidence, and knee buckling, and underwent quantitative gait analysis to quantify varus-valgus excursion and angular velocity. Physical function was assessed using the Late-Life Function and Disability Instrument Basic and Advanced Lower Extremity Domain scores. Logistic regression was used to evaluate the relationship between baseline instability measures and baseline-to-2-year function outcome, adjusting for potential confounders. The sample was comprised of 212 persons (mean age 64.6 years, 76.9% women). Buckling was significantly associated with poor advanced function outcome (adjusted odds ratio [OR] 2.08, 95% confidence interval [95% CI] 1.03-4.20) but not basic function outcome. Overall knee confidence was significantly associated with advanced outcome (adjusted OR 1.65, 95% CI 1.01-2.70), while associations between buckling confidence and both outcomes approached significance. Neither varus-valgus excursion nor angular velocity during gait was associated with either outcome. Knee buckling and low knee confidence were each associated with poor 2-year advanced function outcomes. Current treatment does not address these modifiable factors; interventions to address them may improve outcome in knee OA. © 2015, American College of Rheumatology.

  2. Real-Time Tracking of Knee Adduction Moment in Patients with Knee Osteoarthritis

    PubMed Central

    Kang, Sang Hoon; Lee, Song Joo; Zhang, Li-Qun

    2014-01-01

    Background The external knee adduction moment (EKAM) is closely associated with the presence, progression, and severity of knee osteoarthritis (OA). However, there is a lack of convenient and practical method to estimate and track in real-time the EKAM of patients with knee OA for clinical evaluation and gait training, especially outside of gait laboratories. New Method A real-time EKAM estimation method was developed and applied to track and investigate the EKAM and other knee moments during stepping on an elliptical trainer in both healthy subjects and a patient with knee OA. Results Substantial changes were observed in the EKAM and other knee moments during stepping in the patient with knee OA. Comparison with Existing Method(s) This is the first study to develop and test feasibility of real-time tracking method of the EKAM on patients with knee OA using 3-D inverse dynamics. Conclusions The study provides us an accurate and practical method to evaluate in real-time the critical EKAM associated with knee OA, which is expected to help us to diagnose and evaluate patients with knee OA and provide the patients with real-time EKAM feedback rehabilitation training. PMID:24361759

  3. The Effect of Patellar Thickness on Intraoperative Knee Flexion and Patellar Tracking in Patients With Arthrofibrosis Undergoing Total Knee Arthroplasty.

    PubMed

    Kim, Abraham D; Shah, Vivek M; Scott, Richard D

    2016-05-01

    We evaluated the intraoperative effect of patellar thickness on intraoperative passive knee flexion and patellar tracking during total knee arthroplasty (TKA) in patients with preoperative arthrofibrosis and compared them to patients with normal preoperative range of motion (ROM) documented in a prior study. Routine posterior cruciate ligament-retaining TKA was performed in a total of 34 knees, 23 with normal ROM and 11 with arthrofibrosis, defined as ≤100° of passive knee flexion against gravity under anesthesia. Once clinical balance and congruent patellar tracking were established, custom trial patellar components thicker than the standard trial by 2-mm increments (2-8 mm) were sequentially placed and trialed. Passive flexion against gravity was recorded using digital photograph goniometry. Gross mechanics of patellofemoral tracking were visually assessed. On average, passive knee flexion decreased 2° for every 2-mm increment of patellar thickness (P < .0001), which was similar to patients with normal preoperative ROM. In addition, increased patellar thickness had no gross effect on patellar subluxation and tilt in patients with arthrofibrosis as well as those with normal ROM. Patellar thickness had a modest effect on intraoperative passive flexion and no effect on patellar tracking in patients with arthrofibrosis undergoing TKA. There was no marked difference in intraoperative flexion and patellar tracking between patients with arthrofibrosis and patients with normal preoperative ROM. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Periprosthetic Fractures Following Total Knee Arthroplasty

    PubMed Central

    Kim, Nam Ki

    2015-01-01

    Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthetic tibial fractures are frequently associated with loose components and malalignment or malposition of implants. Fractures of the patella are much less common and associated with rheumatoid arthritis, use of steroid, osteonecrosis and malalignment of implants. Most patients with periprosthetic fractures around the knee are the elderly with poor bone quality. There are many difficulties and increased risk of nonunion after treatment because reduction and internal fixation is interfered with by preexisting prosthesis and bone cement. Additionally, previous soft tissue injury is another disadvantageous condition for bone healing. Many authors reported good clinical outcomes after non-operative treatment of undisplaced or minimally displaced periprosthetic fractures; however, open reduction or revision arthroplasty was required in displaced fractures or fractures with unstable prosthesis. Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a periprosthetic fracture occurs, an appropriate treatment method should be selected considering the stability of the prosthesis, displacement of fracture and bone quality. PMID:25750888

  5. Knee Deformities in Children With Down Syndrome: A Focus on Knee Malalignment.

    PubMed

    Duque Orozco, Maria Del Pilar; Abousamra, Oussama; Chen, Brian Po-Jung; Rogers, Kenneth J; Sees, Julieanne P; Miller, Freeman

    Patellofemoral instability (PFI) has been the most reported knee abnormality in people with Down syndrome. Other reported knee abnormalities have been associated with PFI and different management approaches have been described with variable outcomes. The aim of this study was to describe the anatomic variations of the knee in children with Down syndrome. A comparison between knees with and without PFI was performed and our experience in treating knee abnormalities in Down syndrome was also reported. Records of all children with Down syndrome were reviewed. Two groups were identified (knees with and without PFI). Radiographic measurements included the mechanical and anatomic lateral distal femoral angles, medial proximal tibial angle, angle of depression of medial tibial plateau, lateral tibial translation, and distal femoral physis-joint angle. On the lateral view, Insall-Salvati and Blackburne-Peel ratios were measured. The sulcus angle was measured on the tangential view. Measurements were compared between the 2 groups (with and without PFI).Knees with PFI were divided into 3 subgroups based on their treatment (group A: surgical valgus correction, group B: surgical soft tissue procedures for PFI, and group C: conservative treatment). Preoperative radiographs were used for the surgical group and last available radiographs were used for the conservative group. Clinical and radiographic data were compared between the groups. For groups A and B, clinical and radiographic data were also compared between preoperative and last visits. Of the 581 children with Down syndrome, 5% (31 children: 22 females, 9 males) had PFI in 56 knees. Mean age at diagnosis was 11.5±3.5 years. Of the remaining 550 children, 75 children had radiographs for 130 knees. Knees with PFI had significantly more valgus and a larger distal femoral physis-joint angle. Depression of the medial tibial plateau and lateral tibial translation were noted in knees with PFI. Insall-Salvati ratio was higher

  6. The effect of age and knee osteoarthritis on muscle activation patterns and knee joint biomechanics during dual belt treadmill gait.

    PubMed

    Rutherford, Derek; Baker, Matthew; Wong, Ivan; Stanish, William

    2017-06-01

    To compare a group of individuals with moderate medial compartment knee osteoarthritis (OA) to both an age-matched asymptomatic group of older adults and younger adults to determine whether differences in knee joint muscle activation patterns and joint biomechanics exist during gait between these three groups. 20 young adults, 20 older adults, and 40 individuals with moderate knee OA were recruited. Using standardized procedures, surface electromyograms were recorded from the vastus lateralis and medialis, rectus femoris and the medial and lateral hamstrings. All individuals walked on a dual belt instrumented treadmill while segment motions and ground reaction forces were recorded. Sagittal plane motion and net external sagittal and frontal plane moments were calculated. Discrete measures and principal component analyses extracted amplitude and temporal waveform features. Analysis of Variance models using Bonferroni corrections determined between and within group differences in these gait features (α=0.05). Individuals with knee OA have distinct biomechanics and muscle activation patterns when compared to age-matched asymptomatic adults and younger adults whereas differences between the young and older adults were few and included only measures of muscle activation amplitude. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Wear characteristics of UHMW polyethylene by twist method

    NASA Astrophysics Data System (ADS)

    Chișiu, G.; Popescu, A. M.; Tudor, A.; Petrescu, A. M.; Stoica, G. F.; Subhi, K. A.

    2018-01-01

    A wear test of the twist movement was performed as a new method to estimate the in vivo wear behavior of an acetabular cup material for total knee replacements. A series of UHMWPE samples was used to evaluate the dynamic coefficient of friction in twist movement in contact with steel. The experimental data were conducted to validate the related theoretical model developed in the present study.

  8. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Blumentritt, Siegmar

    2010-04-01

    loading of the contralateral side has been demonstrated during ramp and stair descent. Metabolic energy consumption does not vary significantly between the tested knees. Hence, this parameter seems not to be a suitable criterion for assessing microprocessor-controlled knee components. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. How does knee pain affect trunk and knee motion during badminton forehand lunges?

    PubMed

    Huang, Ming-Tung; Lee, Hsing-Hsan; Lin, Cheng-Feng; Tsai, Yi-Ju; Liao, Jen-Chieh

    2014-01-01

    Badminton requires extensive lower extremity movement and a precise coordination of the upper extremity and trunk movements. Accordingly, this study investigated motions of the trunk and the knee, control of dynamic stability and muscle activation patterns of individuals with and without knee pain. Seventeen participants with chronic knee pain and 17 healthy participants participated in the study and performed forehand forward and backward diagonal lunges. This study showed that those with knee pain exhibited smaller knee motions in frontal and horizontal planes during forward lunge but greater knee motions in sagittal plane during backward lunge. By contrast, in both tasks, the injured group showed a smaller value on the activation level of the paraspinal muscles in pre-impact phase, hip-shoulder separation angle, trunk forward inclination range and peak centre of mass (COM) velocity. Badminton players with knee pain adopt a more conservative movement pattern of the knee to minimise recurrence of knee pain. The healthy group exhibit better weight-shifting ability due to a greater control of the trunk and knee muscles. Training programmes for badminton players with knee pain should be designed to improve both the neuromuscular control and muscle strength of the core muscles and the knee extensor with focus on the backward lunge motion.

  10. Knee pain (image)

    MedlinePlus

    ... front of the knee can be due to bursitis, arthritis, or softening of the patella cartilage as ... knee. Overall knee pain can be due to bursitis, arthritis, tears in the ligaments, osteoarthritis of the ...

  11. Disentangled solid state and metastable polymer melt; a solvent free route to high-modulus high-strength tapes and films of UHMWPE

    NASA Astrophysics Data System (ADS)

    Rastogi, Sanjay

    2013-03-01

    Ultra High Molecular Weight Polyethylene (UHMWPE) having average molar mass greater than a million g/mol is an engineering polymer. Due to its light-weight, high abrasion resistance and biocompatibility it is used for demanding applications such as body armour, prostheses etc. At present, because of its high melt viscosity to achieve the uniaxial/biaxial properties in the form of fibers/films the polymer is processed via solution route where nearly 95wt% of the solvent is used to process 5wt% of the polymer. In past several attempts have been made to process the polymer without using any solvent. However, compared to the solvent processing route the achieved mechanical properties were rather poor. Here we show that by controlled synthesis it is feasible to obtain UHMWPE that could be processed free of solvent to make uniaxial tapes and biaxial films, having unprecedented mechanical properties, exceeding that of the solution spun fibers. We address some of the fundamental aspects of chemistry, physics, rheology and processing for the development of desired morphological features to achieve the ultimate mechanical properties in tapes and films. The paper will also address the metastable melt state obtained on melting of the disentangled crystals and its implication on rheology in linear and nonlinear viscoelastic region. Solid state NMR studies will be applied to establish disentangled state in solid state to the polymerisation conditions. References: Macromolecules 2011, 44(14), 5558-5568; Nature Materials 2005, 4, 635-641; Phys Rev Lett 2006, 96(21), 218303-218205. The authors acknowledge financial support by the Dutch Polymer Institute.

  12. [Effect of posterior condylar offset on knee flexion after high-flex posterior-stabilized total knee arthroplasty].

    PubMed

    Zhang, Yu; Liu, Jun; Tian, Meng-qiang; Cheng, Yu; Tian, Zheng-wei; Sun, Zhen-hui; Ma, Xin-long

    2010-05-15

    To determine the effect of the posterior condylar offset (PCO) on intra- and post-operative knee flexion after total knee arthroplasty (TKA) using a high-flex posterior-stabilized (PS) fixed-bearing prosthesis and to discuss it's importance in femoral prosthesis design. The clinical and radiographic materials of 100 consecutive patients (100 knees) were prospectively studied, including 50 men and 50 women, who had undergone primary NexGen LPS-Flex TKAs for end-stage osteoarthritis. All operations were performed by a single surgeon using the same operative technique between March 2005 and October 2006. Pearson's regression analysis was used to assess the relationship between the difference in the pre- and post-operative PCO on true lateral radiographs and the change in knee range of flexion (ROF) under non-weight-bearing conditions. The decrease of the corrected PCO was (3.4 ± 3.3) mm compared with the preoperative value, the restoration of PCO was better in male than female [female (-5.4 ± 3.1) mm vs. male (-1.5 ± 2.0) mm, P < 0.05]. The difference in the corrected PCO after PS TKA demonstrated significantly correlated with the change in 2 years postoperative ROF in male and female, respectively (P < 0.05). While no statistically correlation was observed in the overall group (P > 0.05). Intraoperatively, the difference in the corrected PCO was significantly correlated with the change in ROF in male, female, and the overall group, respectively (P < 0.05). Restoration of PCO plays an important role in the optimization of knee flexion after high-flex PS TKA. Femoral components based on Caucasian anatomic characteristics could not match the native anatomy of distal femurs of Chinese population especially female Chinese. Rotated resection of distal femur with anterior referencing technique usually leads to a decreased PCO and therefore reduces maximal obtainable flexion. Sexual dimorphism in humans and anatomic variations in various ethnic groups should be seriously

  13. Varus thrust and knee frontal plane dynamic motion in persons with knee osteoarthritis.

    PubMed

    Chang, A H; Chmiel, J S; Moisio, K C; Almagor, O; Zhang, Y; Cahue, S; Sharma, L

    2013-11-01

    Varus thrust visualized during walking is associated with a greater medial knee load and an increased risk of medial knee osteoarthritis (OA) progression. Little is known about how varus thrust presence determined by visual observation relates to quantitative gait kinematic data. We hypothesized that varus thrust presence is associated with greater knee frontal plane dynamic movement during the stance phase of gait. Participants had knee OA in at least one knee. Trained examiners assessed participants for varus thrust presence during ambulation. Frontal plane knee motion during ambulation was captured using external passive reflective markers and an 8-camera motion analysis system. To examine the cross-sectional relationship between varus thrust and frontal plane knee motion, we used multivariable regression models with the quantitative motion measures as dependent variables and varus thrust (present/absent) as predictor; models were adjusted for age, gender, body mass index (BMI), gait speed, and knee static alignment. 236 persons [mean BMI: 28.5 kg/m(2) (standard deviation (SD) 5.5), mean age: 64.9 years (SD 10.4), 75.8% women] contributing 440 knees comprised the study sample. 82 knees (18.6%) had definite varus thrust. Knees with varus thrust had greater peak varus angle and greater peak varus angular velocity during stance than knees without varus thrust (mean differences 0.90° and 6.65°/s, respectively). These patterns remained significant after adjusting for age, gender, BMI, gait speed, and knee static alignment. Visualized varus thrust during walking was associated with a greater peak knee varus angular velocity and a greater peak knee varus angle during stance phase of gait. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. The influence of stem length and fixation on initial femoral component stability in revision total knee replacement

    PubMed Central

    Conlisk, N.; Gray, H.; Pankaj, P.; Howie, C. R.

    2012-01-01

    Objectives Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles. Methods A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions. Results Relative motions were found to increase with flexion angle. Stemmed implants reduced relative motions in comparison to stemless implants for uncemented constructs. Relative motions for cemented implants were reduced to one-third of their equivalent uncemented constructs. Conclusions Stems are not necessary for cemented implants when the metaphyseal bone is intact. Short cemented femoral stems confer as much stability as long uncemented stems. PMID:23610659

  15. Associated lateral/medial knee instability and its relevant factors in anterior cruciate ligament-injured knees.

    PubMed

    Yuuki, Arata; Muneta, Takeshi; Ohara, Toshiyuki; Sekiya, Ichiro; Koga, Hideyuki

    2017-03-01

    Associations of lateral/medial knee instability with anterior cruciate ligament (ACL) injury have not been thoroughly investigated. The purposes of this study were to investigate whether lateral/medial knee instability is associated with ACL injury, and to clarify relevant factors for lateral/medial knee instability in ACL-injured knees. One hundred and nineteen patients with unilateral ACL-injured knees were included. Lateral/medial knee instability was assessed with varus/valgus stress X-ray examination for both injured and uninjured knees by measuring varus/valgus angle, lateral/medial joint opening, and lateral/medial joint opening index. Manual knee instability tests for ACL were evaluated to investigate associations between lateral/medial knee instability and anterior and/or rotational instabilities. Patients' backgrounds were evaluated to identify relevant factors for lateral/medial knee instability. Damage on the lateral collateral ligament (LCL) on MRI was also evaluated. All parameters regarding lateral knee instability in injured knees were significantly greater than in uninjured knees. There were significant correlations between lateral knee instability and the Lachman test as well as the pivot shift test. Patients with LCL damage had significantly greater lateral joint opening than those without LCL damage on MRI. Sensitivity of LCL damage on MRI to lateral joint opening was 100%, while its specificity was 36%. No other relevant factors were identified. In medial knee instability, there were also correlations between medial knee instability and the Lachman test/pivot shift test. However, the correlations were weak and other parameters were not significant. Lateral knee instability was greater in ACL-deficient knees than in uninjured knees. Lateral knee instability was associated with ACL-related instabilities as well as LCL damage on MRI, whereas MRI had low specificity to lateral knee instability. On the other hand, the association of medial knee

  16. Femoral component rotation in patellofemoral joint replacement.

    PubMed

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Should the position of the patellar component replicate the vertical median ridge of the native patella?

    PubMed

    Lee, Rae Hyeong; Jeong, Hae Won; Lee, Jin Kyu; Choi, Choong Hyeok

    2017-01-01

    In total knee arthroplasty (TKA), the position of the patellar component can affect patellar tracking. However, the patellar component cannot always replicate the original high point of the patella because of anatomical variance. This study investigated whether altering the highest point of the patella can affect outcomes of primary TKA, especially in patients having a patella with a far-medialized median ridge. A retrospective review was performed for 177 knees (143 patients) treated with primary TKA between July 2011 and March 2014. Group 1 (34 knees) had the patellar component displaced over three millimeters from the median ridge, while Group 2 (143 knees) had the patellar component placed on the original median ridge position. The one-year follow-up outcomes were reviewed, including: patellar tilt angle, Knee Society Score, Feller Patellar Score, and modified Kujala Anterior Knee Pain Score. Mean (±standard deviation) displacement of the patellar component in Group 1 was 3.97±0.97mm lateral to the original position of the median ridge, with a significant decrease in lateral patellar tilt angle (P<0.001). Lateral patellar tilt showed a positive correlation with the medialization of the patellar component (P<0.001, r=0.401). Ability to rise from a chair was better in Group 1 (P=0.025). There were no other between-group differences in other clinical outcomes. There should be no need for the patellar component to replicate the original highest point of the native patella in primary TKA. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. CRPS Knee: How frequently encountered in differential diagnosis of Knee pain?

    PubMed

    Aggarwal, Aakanksha; Agarwal, Anil

    2018-04-13

    We have read with great interest the paper by Catelijne M. van Bussel [1] recently published in Pain Practice. I wish to congratulate the authors for their valuable contributions. In the said article, 12 patients who had complex regional pain syndrome confined to the knee have been included. Though reports have been published involving primarily the knee after total knee arthroplasty [2,3] the incidence of CRPS knee following trauma or otherwise is not well appreciated. We would have appreciated if presence or absence of any inciting event for the development CRPS knee in these 12 patients could be mentioned, which could be helpful in a better diagnosis and management of the patients with CRPS knee. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Difference in knee rotation between total and unicompartmental knee arthroplasties during stair climbing.

    PubMed

    Jung, Myung-Chul; Chung, Jun Young; Son, Kwang-Hyun; Wang, Hui; Hwang, Jaejin; Kim, Jay Joong; Kim, Joon Ho; Min, Byoung-Hyun

    2014-08-01

    The purpose of this study was to compare knee kinematics during stair walking in patients with simultaneous total knee arthroplasty (TKA) and unicompartmental knee arthroplasties (UKA). It was hypothesized that UKA would reproduce more normalized knee kinematics than TKA during stair ascent and descent. Six patients who received UKA in one knee and TKA in the other knee were included in the study. For this study, a four-step staircase was assembled with two force platforms being positioned at the centre of the second and third steps. Each patient was attached with 16 reflective markers at both lower extremities and was asked to perform five roundtrip trials of stair climbing. Kinematic parameters including stance duration, knee angle, vertical ground reaction force (GRF), joint reaction force, and moments were obtained and analysed using a10-camera motion system (VICON, Oxford, UK). Nonparametric Friedman test was used to compare the results between two arthroplasty methods and between stair ascent and descent. Compared to TKA, UKA knees exhibited significantly greater degree of rotation in transverse planes (5.0 degrees during ascent and 6.0 degrees during descent on average), but showed no difference in terms of the other parameters. When comparing the results during stair ascent with descent, overall greater knee angle, vertical GRF, joint reaction force, and moment were observed during stair descent. Both UKA and TKA knees have shown overall similar knee kinematics, though UKA knee may allow greater degree of rotation freedom, which resembles normal knee kinematics during stair walking.

  20. Knee Dislocations

    PubMed Central

    Schenck, Robert C.; Richter, Dustin L.; Wascher, Daniel C.

    2014-01-01

    Background: Traumatic knee dislocation is becoming more prevalent because of improved recognition and increased exposure to high-energy trauma, but long-term results are lacking. Purpose: To present 2 cases with minimum 20-year follow-up and a review of the literature to illustrate some of the fundamental principles in the management of the dislocated knee. Study Design: Review and case reports. Methods: Two patients with knee dislocations who underwent multiligamentous knee reconstruction were reviewed, with a minimum 20-year follow-up. These patients were brought back for a clinical evaluation using both subjective and objective measures. Subjective measures include the following scales: Lysholm, Tegner activity, visual analog scale (VAS), Short Form–36 (SF-36), International Knee Documentation Committee (IKDC), and a psychosocial questionnaire. Objective measures included ligamentous examination, radiographic evaluation (including Telos stress radiographs), and physical therapy assessment of function and stability. Results: The mean follow-up was 22 years. One patient had a vascular injury requiring repair prior to ligament reconstruction. The average assessment scores were as follows: SF-36 physical health, 52; SF-36 mental health, 59; Lysholm, 92; IKDC, 86.5; VAS involved, 10.5 mm; and VAS uninvolved, 2.5 mm. Both patients had excellent stability and were functioning at high levels of activity for their age (eg, hiking, skydiving). Both patients had radiographic signs of arthritis, which lowered 1 subject’s IKDC score to “C.” Conclusion: Knee dislocations have rare long-term excellent results, and most intermediate-term studies show fair to good functional results. By following fundamental principles in the management of a dislocated knee, patients can be given the opportunity to function at high levels. Hopefully, continued advances in the evaluation and treatment of knee dislocations will improve the long-term outcomes for these patients in the

  1. Soft tissue knee contracture of the knee due to melorheostosis, treated by total knee arthroplasty.

    PubMed

    Moulder, Elizabeth; Marsh, Clayton

    2006-10-01

    Melorheostosis is a rare condition which can cause soft tissue joint contractures. We present a case of melorheostosis causing disabling knee joint contracture, treated successfully by total knee arthroplasty.

  2. Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty

    PubMed Central

    Helmy, Naeder; Kühnel, Stefanie P.

    2014-01-01

    Background. Long-term survival of total knee arthroplasty (TKA) is mainly determined by optimal positioning of the components and prosthesis alignment. Implant positioning can be optimized by computer assisted surgery (CAS). Patient specific cutting blocks (PSCB) seem to have the potential to improve component alignment compared to the conventional technique and to be comparable to CAS. Methods. 113 knees were selected for PSI and included in this study. Pre- and postoperative mechanical axis, represented by the hip-knee-angle (HKA), the proximal tibial angle (PTA), the distal femoral angle (DFA), and the tibial slope (TS) were measured and the deviation from expected ideal values was calculated. Results. With a margin of error of ±3°, success rates were 81.4% for HKA, 92.0% for TPA, and 94.7% for DFA. With the margin of error for alignments extended to ±4°, we obtained a success rate of 92.9% for the HKA, 98.2% for the PTA, and 99.1% for the DFA. The TS showed postoperative results of 2.86 ± 2.02° (mean change 1.76 ± 2.85°). Conclusion. PSCBs for TKA seem to restore the overall leg alignment. Our data suggest that each individual component can be implanted accurately and the results are comparable to the ones in CAS. PMID:25254210

  3. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    PubMed Central

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  4. Knee Injuries and Disorders

    MedlinePlus

    Your knee joint is made up of bone, cartilage, ligaments and fluid. Muscles and tendons help the knee joint move. When any of these structures is hurt or diseased, you have knee problems. Knee problems can cause pain and difficulty ...

  5. Knee joint replacement

    MedlinePlus

    ... Knee joint replacement - series References American Academy of Orthopedic Surgeons (AAOS) website. Treatment of osteoarthritis of the knee: evidence-based guideline 2nd edition (summary) . www.aaos.org/research/guidelines/TreatmentofOsteoarthritisoftheKneeGuideline.pdf . Updated May 18, 2013. Accessed ...

  6. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    PubMed

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  7. Cartilage loss patterns within femorotibial contact regions during deep knee bend.

    PubMed

    Michael Johnson, J; Mahfouz, Mohamed R

    2016-06-14

    Osteoarthritis (OA) can alter knee kinematics and stresses. The relationship between cartilage loss in OA and kinematics is unclear, with existing work focusing on static wear and morphology. In this work, femorotibial cartilage maps were coupled with kinematics to investigate the relationship between kinematics and cartilage loss, allowing for more precise treatment and intervention. Cartilage thickness maps were created from healthy and OA subgroups (varus, valgus, and neutral) and mapped to a statistical bone atlas. Video fluoroscopy determined contact regions from 0° to 120° flexion. Varus and valgus subgroups displayed different wear patterns across the range of flexion, with varus knees showing more loss in early flexion and valgus in deeper flexion. For the femur, varus knees had more wear in the medial compartment than neutral or valgus and most wear at both 0° and 20° flexion. In the lateral femoral compartment, the valgus subgroup showed significantly more wear from 20° to 60° flexion as compared to other angles, though varus knees displayed highest magnitude of wear. For the tibia, most medial wear occurred at 0-40° flexion and most lateral occurred after 60° flexion. Knowing more about cartilage changes in OA knees provides insight as to expected wear or stresses on implanted components after arthroplasty. Combining cartilage loss patterns with kinematics allows for pre-surgical intervention and treatments tailored to the patient׳s alignment and kinematics. Reported wear patterns may also serve as a gauge for post-operative loading to be considered when placing implant components. Copyright © 2016. Published by Elsevier Ltd.

  8. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    NASA Astrophysics Data System (ADS)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  9. Periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty.

    PubMed

    Kumar, Arun; Chambers, Iain; Wong, Paul

    2008-06-01

    We report a case of periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty following a trivial fall. At the time of surgery, the components were found to be loose; and there was a large uncontained tibial defect with bone loss and communition at the fracture site. The patient was treated by revision total knee arthroplasty and proximal structural tibial allograft, with a satisfactory result at 5-year follow up. Our case illustrates that a bone-conserving unicompartmental knee arthroplasty, if complicated by a periprosthetic fracture, can also present with a difficult surgical problem. Attention to preoperative planning and to availability of structural allograft for such difficult cases is recommended.

  10. Contact Mechanics and Failure Modes of Compliant Polymeric Bearing Materials for Knee Cartilage Replacement

    NASA Astrophysics Data System (ADS)

    Tohfafarosh, Mariya Shabbir

    Osteoarthritis (OA) is the most common cause of disability affecting millions of people worldwide. Total knee replacement is the current state-of-the-art treatment to alleviate pain and improve mobility among patients in the late stage of knee OA. The current gold standard materials for total knee arthroplasty are cobalt-chromium and ultra-high molecular weight polyethylene (UHMWPE). However, wear debris and implant loosening-related revision persists; consequently, total knee replacements are not universally recommended for all patient subgroups with OA. This work explores the potential of using compliant polymeric materials in knee cartilage replacement devices, which are closer in lubrication and mechanical properties of articular cartilage, to prevent excessive removal of underlying bone and prolong the need for a total knee replacement. Two materials investigated in this thesis are polycarbonate urethane, Bionate 80A, and a novel hydrogel, Cyborgel, both of which have shown promising wear and lubrication properties under physiological loads. Polycarbonate urethane has been previously tested for the effects of gamma sterilization and has shown no significant changes in its mechanical strength or chemical bonds. Since an important aspect of medical device development is the sterilization process, this thesis first evaluated the effect of 30-35 kGy electron beam and gamma radiation on the polymer swell ratio, and the mechanical, chemical and tribological behavior of the novel hydrogel. Three different formulations were mechanically tested, and biphasic material properties were identified using finite element analysis. Fourier transform infrared spectroscopy was used to investigate chemical changes, while the wear properties were tested for 2 million cycles in bovine serum. The results showed no significant difference (p > 0.05) in the swell ratio, mechanical and tribological properties of the electron beam and gamma sterilized hydrogel sample as compared to the

  11. Advanced concepts in knee arthrodesis.

    PubMed

    Wood, Jennifer H; Conway, Janet D

    2015-03-18

    The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty.

  12. Advanced concepts in knee arthrodesis

    PubMed Central

    Wood, Jennifer H; Conway, Janet D

    2015-01-01

    The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty. PMID:25793160

  13. Knee arthrodesis – ultima ratio for the treatment of the infected knee

    PubMed Central

    Tiemann, Andreas H. H.

    2013-01-01

    The irretrievable destruction of the knee due to trauma, tumor or infection is the indication for knee arthrodesis. The main reason for knee arthrodesis in terms of infection ist the infected total knee arthroplasty. Central problem is the definition of the term “irretrievable”. It is based on the subjective opinion of the attending physician and depends on his expert knowledge of this specific entity. The preservation of a functioning extremity is the main goal. This article shows the typical indications and contraindications for knee arthrodesis following septic knee diseases. In addition it gives insight into the biomechanical and technical considerations to be kept in mind. Finally the postoperative care and outcome of different techniques are analysed. PMID:26504699

  14. Superior-inferior position of patellar component affects patellofemoral kinematics and contact forces in computer simulation.

    PubMed

    Nakamura, Shinichiro; Tanaka, Yoshihisa; Kuriyama, Shinichi; Nishitani, Kohei; Ito, Hiromu; Furu, Moritoshi; Matsuda, Shuichi

    2017-06-01

    Anterior knee pain has been reported as a major postoperative complication after total knee arthroplasty, which may lead to patient dissatisfaction. Rotational alignment and the medial-lateral position correlate with patellar maltracking, which can cause knee pain postoperatively. However, the superior-inferior position of the patellar component has not been investigated. The purpose of the current study was to investigate the effects of the patellar superior-inferior position on patellofemoral kinematics and kinetics. Superior, central, and inferior models with a dome patellar component were constructed. In the superior and inferior models, the position of the patellar component translated superiorly and inferiorly, respectively, by 3mm, relative to the center model. Kinematics of the patellar component, quadriceps force, and patellofemoral contact force were calculated using a computer simulation during a squatting activity in a weight-bearing deep knee bend. In the inferior model, the flexion angle, relative to the tibial component, was the greatest among all models. The inferior model showed an 18.0%, 36.5%, and 22.7% increase in the maximum quadriceps force, the maximum medial patellofemoral force, and the maximum lateral patellofemoral force, respectively, compared with the superior model. Superior-inferior positions affected patellofemoral kinematic and kinetics. Surgeons should avoid the inferior position of the patellar component, because the inferior positioned model showed greater quadriceps and patellofemoral force, resulting in a potential risk for anterior knee pain and component loosening. Copyright © 2017. Published by Elsevier Ltd.

  15. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

    PubMed

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-09-01

    This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (-0.09 mm, 95% confidence interval [CI]: -0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: -1.01 to -0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on

  16. Knee motion variability in patients with knee osteoarthritis: the effect of self-reported instability

    PubMed Central

    Gustafson, Jonathan A.; Robinson, Megan E.; Fitzgerald, G. Kelley; Tashman, Scott; Farrokhi, Shawn

    2015-01-01

    Background Knee osteoarthritis has been previously associated with a stereotypical knee-stiffening gait pattern and reduced knee joint motion variability due to increased antagonist muscle co-contractions and smaller utilized arc of motion during gait. However, episodic self-reported instability may be a sign of excessive motion variability for a large subgroup of patients with knee osteoarthritis. The objective of this work was to evaluate the differences in knee joint motion variability during gait in patients with knee osteoarthritis with and without self-reported instability compared to a control group of older adults with asymptomatic knees. Methods Forty-three subjects, 8 with knee osteoarthritis but no reports of instability (stable), 11 with knee osteoarthritis and self-reported instability (unstable), and 24 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a decline gait task on a treadmill. Knee motion variability was assessed using parametric phase plots during the loading response phase of decline gait. Findings The stable group demonstrated decreased sagittal-plane motion variability compared to the control group (p=0.04), while the unstable group demonstrated increased sagittal-plane motion variability compared to the control (p=0.003) and stable groups (p<0.001). The unstable group also demonstrated increased anterior-posterior joint contact point motion variability for the medial tibiofemoral compartment compared to the control (p=0.03) and stable groups (p=0.03). Interpretation The finding of decreased knee motion variability in patients with knee osteoarthritis without self-reported instability supports previous research. However, presence of self-reported instability is associated with increased knee motion variability in patients with knee osteoarthritis and warrants further investigation. PMID:25796536

  17. Three-dimensional dynamic analysis of knee joint during gait in medial knee osteoarthritis using loading axis of knee.

    PubMed

    Nishino, Katsutoshi; Omori, Go; Koga, Yoshio; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji; Tanaka, Masaei; Arakawa, Masaaki

    2015-07-01

    We recently developed a new method for three-dimensional evaluation of mechanical factors affecting knee joint in order to help identify factors that contribute to the progression of knee osteoarthritis (KOA). This study aimed to verify the clinical validity of our method by evaluating knee joint dynamics during gait. Subjects were 41 individuals (14 normal knees; 8 mild KOAs; 19 severe KOAs). The positions of skin markers attached to the body were captured during gait, and bi-planar X-ray images of the lower extremities were obtained in standing position. The positional relationship between the markers and femorotibial bones was determined from the X-ray images. Combining this relationship with gait capture allowed for the estimation of relative movement between femorotibial bones. We also calculated the point of intersection of loading axis of knee on the tibial proximal surface (LAK point) to analyze knee joint dynamics. Knee flexion range in subjects with severe KOA during gait was significantly smaller than that in those with normal knees (p=0.011), and knee adduction in those with severe KOA was significantly larger than in those with mild KOA (p<0.000). LAK point was locally loaded on the medial compartment of the tibial surface as KOA progressed, with LAK point of subjects with severe KOA rapidly shifting medially during loading response. Local loading and medial shear force were applied to the tibial surface during stance phase as medial KOA progressed. Our findings suggest that our method is useful for the quantitative evaluation of mechanical factors that affect KOA progression. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Finite element analysis of constrained total Condylar Knee Prosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-07-13

    Exactech, Inc., is a prosthetic joint manufacturer based in Gainesville, FL. The company set the goal of developing a highly effective prosthetic articulation, based on scientific principles, not trial and error. They developed an evolutionary design for a total knee arthroplasty system that promised improved performance. They performed static load tests in the laboratory with similar previous designs, but dynamic laboratory testing was both difficult to perform and prohibitively expensive for a small business to undertake. Laboratory testing also cannot measure stress levels in the interior of the prosthesis where failures are known to initiate. To fully optimize their designsmore » for knee arthroplasty revisions, they needed range-of-motion stress/strain data at interior as well as exterior locations within the prosthesis. LLNL developed computer software (especially NIKE3D) specifically designed to perform stress/strain computations (finite element analysis) for complex geometries in large displacement/large deformation conditions. Additionally, LLNL had developed a high fidelity knee model for other analytical purposes. The analysis desired by Exactech could readily be performed using NIKE3D and a modified version of the high fidelity knee that contained the geometry of the condylar knee components. The LLNL high fidelity knee model was a finite element computer model which would not be transferred to Exactech during the course of this CRADA effort. The previously performed laboratory studies by Exactech were beneficial to LLNL in verifying the analytical capabilities of NIKE3D for human anatomical modeling. This, in turn, gave LLNL further entree to perform work-for-others in the prosthetics field. There were two purposes to the CRADA (1) To modify the LLNL High Fidelity Knee Model to accept the geometry of the Exactech Total Knee; and (2) To perform parametric studies of the possible design options in appropriate ranges of motion so that an optimum design

  19. Radiographic and scintigraphic evaluation of total knee arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, R.; Soudry, M.

    1986-04-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic totalmore » knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent.« less

  20. Long-term outcome of 42 knees with chronic infection after total knee arthroplasty.

    PubMed

    Bose, W J; Gearen, P F; Randall, J C; Petty, W

    1995-10-01

    The outcome of treatment in 40 patients (42 knees) with chronic infections after total knee arthroplasty was reviewed. Eighteen knees were treated with a 2-stage reimplantation. Sixteen of these 18 knees were treated with antibiotic-containing beads between debridement and reimplantation, and 7 of these were also treated with antibiotics in the cement at reimplantation. Infection did not recur in any of these 18 knees. Clinically, the 2-stage reimplantation group averaged a score of 90 points on the Knee Society Clinical Rating System. Average function score was 86.5 points, with average range of motion from 2 degrees to 109 degrees. Sixteen knees were treated with an arthrodesis: 9 with a 1-stage technique with a uniplanar external fixator and 7 with a 2-stage technique with intramedullary nail internal fixation. Infection did not recur in 6 of 9 knees treated with the 1-stage technique, but only 2 had a solid arthrodesis. All 7 treated with the 2-stage intramedullary nail technique had no recurrence of infection and achieved a solid fusion. Reimplantation or arthrodesis was not attempted in 8 other knees because of recalcitrant infection, vascular complications, or medical infirmity. Of the 42 knees, 11 (26%) had a severely morbid outcome. The infection could not be eradicated in 7 knees: 6 required amputation and 1 had a solid fusion but chronic drainage. In 3 knees, the infection was cured but resection arthroplasties were required, and in 1 patient an amputation was needed as a result of an intraoperative vascular complication.

  1. Total knee arthroplasty in patients with a prior fracture of the tibial plateau.

    PubMed

    Weiss, Nicholas G; Parvizi, Javad; Trousdale, Robert T; Bryce, Rex D; Lewallen, David G

    2003-02-01

    A fracture of the tibial plateau may predispose the knee to the development of posttraumatic arthritis. Malunion, intra-articular chondro-osseous defects, limb malalignment, retained internal fixation devices, and poor surrounding soft tissues may in turn compromise the outcome of total knee arthroplasty. The aim of our study was to evaluate the results of total knee arthroplasty in patients with a previous fracture of the tibial plateau. The results of sixty-two condylar total knee arthroplasties performed with cement, from 1988 to 1999, in sixty-two patients with a previous fracture of the tibial plateau were reviewed. The fracture of the tibial plateau had been treated by open reduction and internal fixation in thirty-eight knees, external fixation in one knee, and nonoperatively in twenty-three knees. There were forty women and twenty-two men with an average age of sixty-three years at the time of the arthroplasty. Knee Society scores were recorded preoperatively and at the time of follow-up, at an average of 4.7 years, and complications were noted. No patient was lost to follow-up. The mean Knee Society scores improved significantly (p < 0.0001), from 43.9 points for pain and 52 points for function preoperatively to 82.9 and 84 points, respectively, at the time of the latest follow-up. There were thirteen reoperations, which included manipulation with the patient under anesthesia (five knees), wound revision (three knees), and component revision (five knees). There were six intraoperative complications (10%). A postoperative complication occurred in sixteen knees (26%). The vast majority of patients treated with total knee arthroplasty after a previous fracture of the tibial plateau have substantial improvement in function and relief of pain. However, these patients are at increased risk for perioperative complications, as evidenced by the high reoperation rate of 21% in this study.

  2. Risk factors associated with reduced work productivity among people with chronic knee pain.

    PubMed

    Agaliotis, M; Fransen, M; Bridgett, L; Nairn, L; Votrubec, M; Jan, S; Heard, R; Mackey, M

    2013-09-01

    To determine the burden and risk factors associated with reduced work productivity among people with chronic knee pain. A longitudinal study, nested within a randomised controlled trial (RCT) evaluating the long-term effects of dietary supplements, was conducted among people with chronic knee pain in paid employment (n = 360). Participants recorded days off work (absenteeism) and reduced productivity while at work (presenteeism) for seven days every two months over a 12-month period in a study specific diary. Examined risk factors included knee pain severity, occupational group, radiographic disease severity, physical activity, body mass index (BMI), health-related quality of life (SF-12) and co-morbidity. Over the 12-month follow up period, 50 (14%) participants reported one or more days off work due to knee problems, while 283 (79%) reported reduced productivity while at work (presenteeism <100%). In multivariate analysis, the only significant risk factor for absenteeism was having an SF-12 Mental Component Summary (MCS) score <40 (OR: 2.49 [95% CI: 1.03-5.98]). Significant risk factors for presenteeism included; reporting an; SF-12 Physical Component Summary (PCS) score <50 (OR: 1.99 [95% CI: 1.05-3.76]), semi-manual labour (OR: 2.23 [1.09-4.59]) or manual labour (OR: 6.40 [1.44-28.35]) or a high maximum knee pain (4-6 out of 10) (OR: 2.29 [1.17-4.46]). This longitudinal study found that among this cohort of people with chronic knee pain, the burden of reduced work productivity is mainly attributable to presenteeism rather absenteeism. This study demonstrated that effective strategies to increase work productivity should focus on reducing knee pain or physical disability especially among workers in manual or semi-manual labour. © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  3. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    PubMed Central

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by

  4. Can generic knee joint models improve the measurement of osteoarthritic knee kinematics during squatting activity?

    PubMed

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2017-01-01

    Knee joint kinematics derived from multi-body optimisation (MBO) still requires evaluation. The objective of this study was to corroborate model-derived kinematics of osteoarthritic knees obtained using four generic knee joint models used in musculoskeletal modelling - spherical, hinge, degree-of-freedom coupling curves and parallel mechanism - against reference knee kinematics measured by stereo-radiography. Root mean square errors ranged from 0.7° to 23.4° for knee rotations and from 0.6 to 9.0 mm for knee displacements. Model-derived knee kinematics computed from generic knee joint models was inaccurate. Future developments and experiments should improve the reliability of osteoarthritic knee models in MBO and musculoskeletal modelling.

  5. REHABILITATION FOLLOWING KNEE DISLOCATION WITH LATERAL SIDE INJURY: IMPLEMENTATION OF THE KNEE SYMMETRY MODEL

    PubMed Central

    Jenkins, Walter; Urch, Scott E.; Shelbourne, K. Donald

    2010-01-01

    Rehabilitation following lateral side knee ligament repair or reconstruction has traditionally utilized a conservative approach. An article outlining a new concept in rehabilitation following ACL reconstruction called the Knee Symmetry Model was recently published13. The Knee Symmetry Model can also be applied to rehabilitation of other knee pathologies including a knee dislocation with a lateral side injury. This Clinical Commentary describes the rehabilitation procedures used with patients who underwent surgery to repair lateral side ligaments, based upon the Knee Symmetry Model. These procedures were used previously to rehabilitate a group of patients with lateral side ligament repair as reported by Shelbourne et al10. Outcome data and subjective knee scores for these patients were recorded via the International Knee Documentation Committee (IKDC) guidelines and modified Noyes survey scores and are summarized in this paper, as previously published. Rehabilitation following lateral side knee ligament repair using guidelines based upon the Knee Symmetry Model appears to provide patients with excellent long-term stability, normal ROM and strength, and a high level of function. PMID:21589671

  6. Association Between Pain at Sites Outside the Knee and Knee Cartilage Volume Loss in Elderly People Without Knee Osteoarthritis: A Prospective Study.

    PubMed

    Pan, Feng; Laslett, Laura; Tian, Jing; Cicuttini, Flavia; Winzenberg, Tania; Ding, Changhai; Jones, Graeme

    2017-05-01

    Pain is common in the elderly. Knee pain may predict knee cartilage loss, but whether generalized pain is associated with knee cartilage loss is unclear. This study, therefore, aimed to determine whether pain at multiple sites predicts knee cartilage volume loss among community-dwelling older adults, and, if so, to explore potential mechanisms. Data from the prospective Tasmanian Older Adult Cohort study was utilized (n = 394, mean age 63 years, range 52-79 years). Experience of pain at multiple sites was assessed using a questionnaire at baseline. T1-weighted fat-saturated magnetic resonance imaging of the right knee was performed to assess the cartilage volume at baseline and after 2.6 years. Linear regression modeling was used with adjustment for potential confounders. The median number of painful sites was 3 (range 0-7). There was a dose-response relationship between the number of painful sites and knee cartilage volume loss in the lateral and total tibiofemoral compartments (lateral β = -0.28% per annum; total β = -0.25% per annum, both P for trend < 0.05), but not in the medial compartment. These associations were stronger in participants without radiographic knee osteoarthritis (OA) (P < 0.05) and independent of age, sex, body mass index, physical activity, pain medication, and knee structural abnormalities. The number of painful sites independently predicts knee cartilage volume loss, especially in people without knee OA, suggesting that widespread pain may be an early marker of more rapid knee cartilage loss in those without radiographic knee OA. The underlying mechanism is unclear, but it is independent of anthropometrics, physical activity, and knee structural abnormalities. © 2016, American College of Rheumatology.

  7. Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion.

    PubMed

    Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong

    2018-01-01

    Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.

  8. Status, methods and aims of the knee investigations at CR spectrum

    NASA Astrophysics Data System (ADS)

    Shaulov, S. B.; Bezshapov, S. P.

    2013-02-01

    Usually it is supposed that the definition of the CR mass composition in knee region is the key to problem of CR spectrum modification in this range. However tens of experiments done for the last half a century, have not decided this problem. The possible causes of fiasco and arguments in favour of necessity to reformulate a method of attack are discussed. It is formulated that the first experimental task now is to solve a more simple problem: is there abnormal CR component in knee field or not. It seams that impossible to formulate correctly more common problem of mass composition without solving of this one. The observational basis is discussed. The hypothesis of strange quark matter is suggested for the abnormal component.

  9. What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty?

    PubMed

    Nedopil, Alexander J; Howell, Stephen M; Hull, Maury L

    2017-02-01

    Thirteen patients presented with patellofemoral instability out of 3212 knees treated with kinematically aligned total knee arthroplasty (KA TKA) during a nine year period. We determined the clinical characteristics and post-operative radiographic parameters associated with patellofemoral instability, and whether re-operation and patient reported outcome measures are different between patients with and without patellofemoral instability. Patients with patellofemoral instability were matched 1:3 to a control cohort based on date of surgery (±3 months), age (±10 years), sex, pre-operative knee deformity (varus or valgus), and implant brand. We analyzed clinical characteristics and seven post-operative radiographic parameters. Patellofemoral instability presented atraumatically (12 of 13) at 5 ± 4.7 months for a 0.4 % incidence at a mean follow-up of 43 ± 36 months. No pre-operative clinical characteristics were associated with instability. Patients with patellofemoral instability had greater flexion of the femoral component (11° versus 5°; p = 0.0012), a trend toward greater external rotation of the tibial component (2° versus 0°; p = 0.2704), more reoperations (9 versus 0; p = 0.0026) and a lower Oxford Knee Score (36 versus 42; p = 0.0045) than controls. Patellofemoral instability after kinematically aligned TKA is infrequent, presents atraumatically, and is associated with greater flexion of the femoral component than the control group. Minimizing flexion of the femoral component might reduce the risk of patellofemoral instability by promoting early engagement of the patella in the trochlear during knee flexion.

  10. Relation between peak knee flexion angle and knee ankle kinetics in single-leg jump landing from running: a pilot study on male handball players to prevent ACL injury.

    PubMed

    Ameer, Mariam A; Muaidi, Qassim I

    2017-09-01

    The relationship between knee kinematics and knee-ankle kinetics during the landing phase of single leg jumping has been widely studied to identify proper strategies for preventing non-contact ACL injury. However, there is a lack of study on knee-ankle kinetics at peak knee flexion angle during jumping from running. Hence, the purpose of this study is to establish the relationship between peak knee flexion angle, knee extension moment, ankle plantar flexion moment and ground reaction force in handball players in order to protect ACL from excessive stress during single leg jumping. In addition, the study also clarifies the role of calf muscles in relieving part of ACL stresses with different knee flexion angles during landing. Fifteen active male elite handball players of Saudi Arabia have participated in this study (Age = 22.6 ± 3.5years, Height = 182 ± 3.7 cm, Weight = 87.5 ± 10.2 kg). The players performed three successful landings of single-leg jump following running a fixed distance of about 450cm. The data were collected using a 3D motion capture and analysis system (VICON). Pearson product moment correlation coefficients showed that greater peak knee flexion angle is related significantly to both lesser knee extension moment (r = -.623, P = .013) and vertical component of ground reaction force (VGRF) (r = -.688, P = .005) in landing phase. Moreover, increasing the peak knee flexion angle in landing phase tends to increase the ankle plantar flexion moment significantly (r = .832, P = .000). With an increase of the peak knee flexion angle during single leg jump landing from running, there would be less knee extension moment, low impact force and more plantar flexion moment. As such, the clinical implication of this study is that there may be a possible protective mechanism by increasing the knee flexion angle during landing phase, which tends to protect the ACL from vigorous strain and injuries.

  11. Lessons learned from selective soft-tissue release for gap balancing in primary total knee arthroplasty: an analysis of 1216 consecutive total knee arthroplasties: AAOS exhibit selection.

    PubMed

    Peters, Christopher L; Jimenez, Chris; Erickson, Jill; Anderson, Mike B; Pelt, Christopher E

    2013-10-16

    Soft-tissue releases are commonly necessary to achieve symmetrical flexion and extension gaps in primary total knee arthroplasty performed with a measured resection technique. We reviewed the frequency of required releases according to preoperative alignment and the clinical and radiographic results; associations with failure, reoperations, and complications are presented. We reviewed 1216 knees that underwent primary total knee arthroplasty from 2004 to 2009; 774 (64%) were in female patients and 442 (36%), in male patients. In the coronal plane, 855 knees had preoperative varus deformity, 123 were neutral, and 238 had valgus deformity. The mean age at the time of the index procedure was 62.7 years (range, twenty-three to ninety-four years), and the mean body mass index was 32.7 kg/m² (range, 17.4 to 87.9 kg/m²). Clinical outcomes included the Knee Society Score (KSS), implant failure, reoperation, and complications. Radiographs were analyzed for component alignment. The only difference in the total KSS was found at the time of final follow-up between valgus knees with zero releases (total KSS = 178) and those with one or two releases (KSS = 160, p = 0.026). Overall, 407 knees (33.5%) required zero releases, 686 (56.4%) required one or two releases, and 123 (10.1%) required three or more releases. Among varus knees, 37% required zero releases, 55% required one or two releases, and 7.5% required three or more releases. Among neutral knees, 39% required zero releases, 55% required one or two releases, and 5.7% required three or more releases. Only 17% of valgus knees required zero releases whereas 61% required one or two releases and 21.8% required three or more releases. Valgus knees required more releases than neutral or varus knees did (p < 0.001). Selective soft-tissue release for gap balancing in primary total knee arthroplasty is an effective technique that produced excellent clinical and radiographic results regardless of preoperative alignment. Consistent

  12. Knee Bursitis

    MedlinePlus

    ... bursa) situated near your knee joint. Bursae reduce friction and cushion pressure points between your bones and ... But most cases of knee bursitis result from friction and irritation of the bursa that occurs in ...

  13. Knee pain

    MedlinePlus

    ... the kneecap. Torn ligament. An anterior cruciate ligament (ACL) injury, or medial collateral ligament (MCL) injury may ... need surgery. Alternative Names Pain - knee Patient Instructions ACL reconstruction - discharge Hip or knee replacement - after - what ...

  14. Three-dimensional knee motion before and after high tibial osteotomy for medial knee osteoarthritis.

    PubMed

    Takemae, Takashi; Omori, Go; Nishino, Katsutoshi; Terajima, Kazuhiro; Koga, Yoshio; Endo, Naoto

    2006-11-01

    High tibial osteotomy (HTO) is an established surgical option for treating medial knee osteoarthritis. HTO moves the mechanical load on the knee joint from the medial compartment to the lateral compartment by changing the leg alignment, but the effects of the operation remain unclear. The purpose of this study was to evaluate the change in three-dimensional knee motion before and after HTO, focusing on lateral thrust and screw home movement, and to investigate the relationship between the change in knee motion and the clinical results. A series of 19 patients with medial knee osteoarthritis who had undergone HTO were evaluated. We performed a clinical assessment, radiological evaluation, and motion analysis at 2.4 years postoperatively. The clinical assessment was performed using the Japanese Orthopaedic Association knee score. The score was significantly improved in all patients after operation. Motion analysis revealed that lateral thrust, which was observed in 18 of the 20 knees before operation, was reduced to 7 knees after operation. Regarding active terminal extension of the knee, three patterns of rotational movement were observed before operation: screw home movement (external rotation), reverse screw home movement (internal rotation), and no rotation. By contrast, after operation, only reverse screw home movement and no rotation were observed; the screw home movement disappeared in all patients. In the knees with reverse screw home movement after operation, the preoperative score was significantly lower than those in the knees with no rotation after operation. Kinetically, HTO was useful for suppressing lateral thrust in medial knee osteoarthritis, although the rotational movement of the knee joint was unchanged.

  15. An improved OpenSim gait model with multiple degrees of freedom knee joint and knee ligaments.

    PubMed

    Xu, Hang; Bloswick, Donald; Merryweather, Andrew

    2015-08-01

    Musculoskeletal models are widely used to investigate joint kinematics and predict muscle force during gait. However, the knee is usually simplified as a one degree of freedom joint and knee ligaments are neglected. The aim of this study was to develop an OpenSim gait model with enhanced knee structures. The knee joint in this study included three rotations and three translations. The three knee rotations and mediolateral translation were independent, with proximodistal and anteroposterior translations occurring as a function of knee flexion/extension. Ten elastic elements described the geometrical and mechanical properties of the anterior and posterior cruciate ligaments (ACL and PCL), and the medial and lateral collateral ligaments (MCL and LCL). The three independent knee rotations were evaluated using OpenSim to observe ligament function. The results showed that the anterior and posterior bundles of ACL and PCL (aACL, pACL and aPCL, pPCL) intersected during knee flexion. The aACL and pACL mainly provided force during knee flexion and adduction, respectively. The aPCL was slack throughout the range of three knee rotations; however, the pPCL was utilised for knee abduction and internal rotation. The LCL was employed for knee adduction and rotation, but was slack beyond 20° of knee flexion. The MCL bundles were mainly used during knee adduction and external rotation. All these results suggest that the functions of knee ligaments in this model approximated the behaviour of the physical knee and the enhanced knee structures can improve the ability to investigate knee joint biomechanics during various gait activities.

  16. Manual for guided home exercises for osteoarthritis of the knee

    PubMed Central

    de Almeida Carvalho, Nilza Aparecida; Bittar, Simoni Teixeira; de Souza Pinto, Flávia Ribeiro; Ferreira, Mônica; Sitta, Robson Roberto

    2010-01-01

    INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (≥ 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial. PMID:20835554

  17. Manual for guided home exercises for osteoarthritis of the knee.

    PubMed

    Carvalho, Nilza Aparecida de Almeida; Bittar, Simoni Teixeira; Pinto, Flávia Ribeiro de Souza; Ferreira, Mônica; Sitta, Robson Roberto

    2010-06-01

    Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. Thirty-eight adults with osteoarthritis of the knee (>or= 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial.

  18. Knee Replacement

    MedlinePlus

    ... a knee replacement is right for you, an orthopedic surgeon assesses your knee's range of motion, stability ... trademarks of Mayo Foundation for Medical Education and Research. © 1998-2018 Mayo Foundation for Medical Education and ...

  19. Muscle contributions to knee extension in the early stance phase in patients with knee osteoarthritis.

    PubMed

    Ogaya, Shinya; Kubota, Ryo; Chujo, Yuta; Hirooka, Eiko; Kwang-Ho, Kim; Hase, Kimitaka

    2017-10-01

    The aim of this study was to analyze individual muscle contributions to knee angular acceleration using a musculoskeletal simulation analysis and evaluate knee extension mechanics in the early stance phase in patients with knee osteoarthritis (OA). The subjects comprised 15 patients with medial knee OA and 14 healthy elderly individuals. All participants underwent gait performance test using 8 infrared cameras and two force plates to measure the kinetic and kinematic data. The simulation was driven by 92 Hill-type muscle-tendon units of the lower extremities and a trunk with 23° of freedom. We analyzed each muscle contribution to knee angular acceleration in the 5%-15% and 15%-25% periods of the stance phase (% SP) using an induced acceleration analysis. We compared accelerations by individual muscles between the two groups using an analysis of covariance for controlling gait speed. Patients with knee OA had a significantly lesser knee extension acceleration by the vasti muscles and higher knee acceleration by hip adductors than those in controls in 5-15% SP. In addition, knee OA resulted in significantly lesser knee extension acceleration by the vasti muscles in 15-25% SP. These results indicate that patients with knee OA have decreased dependency on the vasti muscles to control knee movements during early stance phase. Hip adductor muscles, which mainly control mediolateral motion, partly compensate for the weak knee extension by the vasti muscles in patients with knee OA. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.

    PubMed

    Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto

    2011-01-27

    The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.

  1. Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis.

    PubMed

    Levinger, Pazit; Lai, Daniel T H; Menz, Hylton B; Morrow, Adam D; Feller, Julian A; Bartlett, John R; Bergman, Neil R; Begg, Rezaul

    2012-02-01

    Knee osteoarthritis (OA) has been shown to be a risk factor for falls. Reductions in foot clearance during the swing phase of walking can cause a trip and potentially lead to a fall. This study examined the swing phase mechanics of people with and without knee OA during walking. Minimum toe clearance (MTC) height, joint angles at the time of MTC and the influence of the angular changes of the hip, knee and ankle of the swing leg on foot clearance using sensitivity analysis were investigated in 50 knee OA participants and 28 age-matched asymptomatic controls. Although both groups had a similar MTC height (controls: 12.8±6.7 mm, knee OA: 13.4±7.0 mm), the knee OA group used a different strategy to achieve the same foot clearance, as evidenced by greater knee flexion (52.5±5.3° vs 49.4±4.8°, p=0.007), greater hip abduction (-3.6±3.3° vs -1.8±3.3°, p=0.03) and less ankle adduction (2.8±1.9° vs 4.2±2.1°, p=0.01). MTC height was comparable between the groups, however a different swing phase mechanism was used by the knee OA. Although adequate MTC is an important component of safe locomotion, it does not appear to be impaired in people with knee OA. Other factors, such as inadequate responses to postural perturbation, may be responsible for falls in this group. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Technology Efficacy in Active Prosthetic Knees for Transfemoral Amputees: A Quantitative Evaluation

    PubMed Central

    El-Sayed, Amr M.; Abu Osman, Noor Azuan

    2014-01-01

    Several studies have presented technological ensembles of active knee systems for transfemoral prosthesis. Other studies have examined the amputees' gait performance while wearing a specific active prosthesis. This paper combined both insights, that is, a technical examination of the components used, with an evaluation of how these improved the gait of respective users. This study aims to offer a quantitative understanding of the potential enhancement derived from strategic integration of core elements in developing an effective device. The study systematically discussed the current technology in active transfemoral prosthesis with respect to its functional walking performance amongst above-knee amputee users, to evaluate the system's efficacy in producing close-to-normal user performance. The performances of its actuator, sensory system, and control technique that are incorporated in each reported system were evaluated separately and numerical comparisons were conducted based on the percentage of amputees' gait deviation from normal gait profile points. The results identified particular components that contributed closest to normal gait parameters. However, the conclusion is limitedly extendable due to the small number of studies. Thus, more clinical validation of the active prosthetic knee technology is needed to better understand the extent of contribution of each component to the most functional development. PMID:25110727

  3. Technology efficacy in active prosthetic knees for transfemoral amputees: a quantitative evaluation.

    PubMed

    El-Sayed, Amr M; Hamzaid, Nur Azah; Abu Osman, Noor Azuan

    2014-01-01

    Several studies have presented technological ensembles of active knee systems for transfemoral prosthesis. Other studies have examined the amputees' gait performance while wearing a specific active prosthesis. This paper combined both insights, that is, a technical examination of the components used, with an evaluation of how these improved the gait of respective users. This study aims to offer a quantitative understanding of the potential enhancement derived from strategic integration of core elements in developing an effective device. The study systematically discussed the current technology in active transfemoral prosthesis with respect to its functional walking performance amongst above-knee amputee users, to evaluate the system's efficacy in producing close-to-normal user performance. The performances of its actuator, sensory system, and control technique that are incorporated in each reported system were evaluated separately and numerical comparisons were conducted based on the percentage of amputees' gait deviation from normal gait profile points. The results identified particular components that contributed closest to normal gait parameters. However, the conclusion is limitedly extendable due to the small number of studies. Thus, more clinical validation of the active prosthetic knee technology is needed to better understand the extent of contribution of each component to the most functional development.

  4. Ultra high molecular weight polyethylene (UHMWPE) fiber epoxy composite hybridized with Gadolinium and Boron nanoparticles for radiation shielding

    NASA Astrophysics Data System (ADS)

    Mani, Venkat; Prasad, Narasimha S.; Kelkar, Ajit

    2016-09-01

    Deep space radiations pose a major threat to the astronauts and their spacecraft during long duration space exploration missions. The two sources of radiation that are of concern are the galactic cosmic radiation (GCR) and the short lived secondary neutron radiations that are generated as a result of fragmentation that occurs when GCR strikes target nuclei in a spacecraft. Energy loss, during the interaction of GCR and the shielding material, increases with the charge to mass ratio of the shielding material. Hydrogen with no neutron in its nucleus has the highest charge to mass ratio and is the element which is the most effective shield against GCR. Some of the polymers because of their higher hydrogen content also serve as radiation shield materials. Ultra High Molecular Weight Polyethylene (UHMWPE) fibers, apart from possessing radiation shielding properties by the virtue of the high hydrogen content, are known for extraordinary properties. An effective radiation shielding material is the one that will offer protection from GCR and impede the secondary neutron radiations resulting from the fragmentation process. Neutrons, which result from fragmentation, do not respond to the Coulombic interaction that shield against GCR. To prevent the deleterious effects of secondary neutrons, targets such as Gadolinium are required. In this paper, the radiation shielding studies that were carried out on the fabricated sandwich panels by vacuum-assisted resin transfer molding (VARTM) process are presented. VARTM is a manufacturing process used for making large composite structures by infusing resin into base materials formed with woven fabric or fiber using vacuum pressure. Using the VARTM process, the hybridization of Epoxy/UHMWPE composites with Gadolinium nanoparticles, Boron, and Boron carbide nanoparticles in the form of sandwich panels were successfully carried out. The preliminary results from neutron radiation tests show that greater than 99% shielding performance was

  5. Extrinsic Factors as Component Positions to Bone and Intrinsic Factors Affecting Postoperative Rotational Limb Alignment in Total Knee Arthroplasty.

    PubMed

    Mochizuki, Tomoharu; Sato, Takashi; Tanifuji, Osamu; Watanabe, Satoshi; Kobayashi, Koichi; Endo, Naoto

    2018-02-13

    This study aimed to identify the factors affecting postoperative rotational limb alignment of the tibia relative to the femur. We hypothesized that not only component positions but also several intrinsic factors were associated with postoperative rotational limb alignment. This study included 99 knees (90 women and 9 men) with a mean age of 77 ± 6 years. A three-dimensional (3D) assessment system was applied under weight-bearing conditions to biplanar long-leg radiographs using 3D-to-2D image registration technique. The evaluation parameters were (1) component position; (2) preoperative and postoperative coronal, sagittal, and rotational limb alignment; (3) preoperative bony deformity, including femoral torsion, condylar twist angle, and tibial torsion; and (4) preoperative and postoperative range of motion (ROM). In multiple linear regression analysis using a stepwise procedure, postoperative rotational limb alignment was associated with the following: (1) rotation of the component position (tibia: β = 0.371, P < .0001; femur: β = -0.327, P < .0001), (2) preoperative rotational limb alignment (β = 0.253, P = .001), (3) postoperative flexion angle (β = 0.195, P = .007), and (4) tibial torsion (β = 0.193, P = .010). In addition to component positions, the intrinsic factors, such as preoperative rotational limb alignment, ROM, and tibial torsion, affected postoperative rotational limb alignment. On a premise of correct component positions, the intrinsic factors that can be controlled by surgeons should be taken care. In particular, ROM is necessary to be improved within the possible range to acquire better postoperative rotational limb alignment. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

    PubMed

    Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther

    2015-03-01

    Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.

  7. Custom-fit total knee arthroplasty: our initial experience with 30 knees.

    PubMed

    Bonicoli, Enrico; Andreani, Lorenzo; Parchi, Paolo; Piolanti, Nicola; Lisanti, Michele

    2014-10-01

    We report our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 30 TKAs from December 2010 to September 2012. Customized blocks were generated for each of the knees using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 30 days, long-leg radiographs were obtained to evaluate the coronal alignment. Twenty-six of the 30 knees had a mechanical axis restored to within 3° of neutral. We conclude that this technology can be safely used in most of the cases of osteoarthritis.

  8. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    PubMed

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  9. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

    PubMed Central

    2011-01-01

    Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA. PMID:21272328

  10. The role of skeletal muscle in the pathophysiology and management of knee osteoarthritis.

    PubMed

    Krishnasamy, Priathashini; Hall, Michelle; Robbins, Sarah R

    2018-05-01

    The role of skeletal muscle in the pathophysiology of knee OA is poorly understood. To date, the majority of literature has focused on the association of muscle strength with OA symptoms, disease onset and progression. However, deficits or improvements in skeletal muscle strength do not fully explain the mechanisms behind outcome measures in knee OA, such as pain, function and structural disease. This review aims to summarize components of skeletal muscle, providing a holistic view of skeletal muscle mechanisms that includes muscle function, quality and composition and their interactions. Similarly, the role of skeletal muscle in the management of knee OA will be discussed.

  11. Shape optimization of tibial prosthesis components

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Davy, D. T.

    1993-01-01

    NASA technology and optimal design methodologies originally developed for the optimization of composite structures (engine blades) are adapted and applied to the optimization of orthopaedic knee implants. A method is developed enabling the shape tailoring of the tibial components of a total knee replacement implant for optimal interaction within the environment of the tibia. The shape of the implant components are optimized such that the stresses in the bone are favorably controlled to minimize bone degradation, to improve the mechanical integrity of the implant/interface/bone system, and to prevent failures of the implant components. A pilot tailoring system is developed and the feasibility of the concept is demonstrated and evaluated. The methodology and evolution of the existing aerospace technology from which this pilot optimization code was developed is also presented and discussed. Both symmetric and unsymmetric in-plane loading conditions are investigated. The results of the optimization process indicate a trend toward wider and tapered posts as well as thicker backing trays. Unique component geometries were obtained for the different load cases.

  12. Associations of knee extensor strength and standing balance with physical function in knee osteoarthritis.

    PubMed

    Pua, Yong-Hao; Liang, Zhiqi; Ong, Peck-Hoon; Bryant, Adam L; Lo, Ngai-Nung; Clark, Ross A

    2011-12-01

    Knee extensor strength is an important correlate of physical function in patients with knee osteoarthritis; however, it remains unclear whether standing balance is also a correlate. The purpose of this study was to evaluate the cross-sectional associations of knee extensor strength, standing balance, and their interaction with physical function. One hundred four older adults with end-stage knee osteoarthritis awaiting a total knee replacement (mean ± SD age 67 ± 8 years) participated. Isometric knee extensor strength was measured using an isokinetic dynamometer. Standing balance performance was measured by the center of pressure displacement during quiet standing on a balance board. Physical function was measured by the self-report Short Form 36 (SF-36) questionnaire and by the 10-meter fast-pace gait speed test. After adjustment for demographic and knee pain variables, we detected significant knee strength by standing balance interaction terms for both SF-36 physical function and fast-pace gait speed. Interrogation of the interaction revealed that standing balance in the anteroposterior plane was positively related to physical function among patients with lower knee extensor strength. Conversely, among patients with higher knee extensor strength, the standing balance-physical function associations were, or tended to be, negative. These findings suggest that although standing balance was related to physical function in patients with knee osteoarthritis, this relationship was complex and dependent on knee extensor strength level. These results are of importance in developing intervention strategies and refining theoretical models, but they call for further study. Copyright © 2011 by the American College of Rheumatology.

  13. Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene.

    PubMed

    Abdelgaied, Abdellatif; Brockett, Claire L; Liu, Feng; Jennings, Louise M; Fisher, John; Jin, Zhongmin

    2013-01-01

    Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be independent and have general applicability and predictability, computational wear models should be based on inputs from independent experimentally determined wear parameters (wear factors or wear coefficients). The objective of this study was to investigate moderately cross-linked UHMWPE, using a multidirectional pin-on-plate wear test machine, under a wide range of applied nominal contact pressure (from 1 to 11 MPa) and under five different kinematic inputs, varying from a purely linear track to a maximum rotation of +/- 55 degrees. A computational model, based on a direct simulation of the multidirectional pin-on-plate wear tester, was developed to quantify the degree of cross-shear (CS) of the polyethylene pins articulating against the metallic plates. The moderately cross-linked UHMWPE showed wear factors less than half of that reported in the literature for, the conventional UHMWPE, under the same loading and kinematic inputs. In addition, under high applied nominal contact stress, the moderately crosslinked UHMWPE wear showed lower dependence on the degree of CS compared to that under low applied nominal contact stress. The calculated wear coefficients were found to be independent of the applied nominal contact stress, in contrast to the wear factors that were shown to be highly pressure dependent. This study provided independent wear data for inputs into computational models for moderately cross-linked polyethylene and supported the application of wear coefficient-based computational wear models.

  14. Investigation of the Influence of Shapes-Texture on Surface Deformation of UHMWPE as a Bearing Material in Static Normal Load and Rolling Contact

    NASA Astrophysics Data System (ADS)

    Lestari, W. D.; Ismail, R.; Jamari, J.; Bayuseno, A. P.

    2017-05-01

    Surface texture is a common method for improving wear properties of a tribo-pair of soft and hard bearing material. The reduction of wear rates on the contacting surface material is becoming important issues. In the present study, analysis of the contact pressure on the flat surface of UHMWPE (Ultra High Molecular Weight Polyethylene) under the static- and rolling motion with the surface of steel ball used the 3D finite element method (FEM) (the ABAQUS software version 6.12). Five shaped-texture models (square, circle, ellipse, triangle, and chevron) were presented on the flat surface for analysis. The normal load of 17, 30 and 50 N was deliberately set-up for static and rolling contact analysis. The contact pressure was determined to predict the wear behavior of the shaped-texture on the flat surface of UHMWPE. The results have shown that the static normal load yielded the lowest von-Mises stress distribution on the shaped-texture of the ellipse for all values applied a load, while the square shape experienced the highest stress distribution. Under rolling contact, however, the increasing load yielded the increasing von Mises stress distribution for the texture with a triangle shape. Moreover, the texture shapes for circle, ellipse, and chevron respectively, may undergo the lowest stress distribution for all load. The wear calculation provided that the circle and square shape may undergo the highest wear rates. Obviously, the surface texture of circle, ellipse, and chevron may experience the lowest wear rates and is potential for use in the surface engineering of bearing materials.

  15. What Are Knee Problems?

    MedlinePlus

    ... some knee problems. When living with knee problems, everyone should get range of motion, strength, and aerobic exercise ... Living With Them When living with knee problems, everyone should get three types of exercise regularly: Range-of- ...

  16. One Stage Conversion of an Infected Fused Knee to Total Knee Replacement - A Surgical Challenge

    PubMed Central

    Ravikumar, Mukartihal; Kendoff, Daniel; Citak, Mustafa; Luck, Stefan; Gehrke, Thorsten; Zahar, Akos

    2013-01-01

    Background and Purpose: Two-stage revision arthroplasty is a common technique for the treatment of infected total knee replacement. Few reports have addressed the conversion of a fused knee into a total knee replacement. However, there is no case reported of converting an infected fused knee into a hinge knee using a one-stage procedure. Methods: We report on a 51-year old male patient with an infected fused knee after multiple surgeries. Results and Interpretation: A one-stage conversion of septic fused knee into total knee arthroplasty by a rotational hinge prosthesis was performed. The case highlights that with profound preoperative assessment, meticulous surgical technique, combined antibiotic treatment and the right implant, one-stage revision in a surgical challenge may have a role as a treatment option with good functional outcome. PMID:23526706

  17. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

    PubMed

    Rao, Anand R; Engh, Gerard A; Collier, Matthew B; Lounici, Smain

    2002-10-01

    Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking

  18. Patterns of functional improvement after revision knee arthroplasty.

    PubMed

    Ghomrawi, Hassan M K; Kane, Robert L; Eberly, Lynn E; Bershadsky, Boris; Saleh, Khaled J

    2009-12-01

    Despite the increase in the number of total knee arthroplasty revisions, outcomes of such surgery and their correlates are poorly understood. The aim of this study was to characterize patterns of functional improvement after revision total knee arthroplasty over a two-year period and to investigate factors that affect such improvement patterns. Three hundred and eight patients in need of revision surgery were enrolled into the study, conducted at seventeen centers, and 221 (71.8%) were followed for two years. Short Form-36 (SF-36), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Lower-Extremity Activity Scale (LEAS) scores were collected at baseline and every six months for two years postoperatively. A piecewise general linear mixed model, which models correlation between repeated measures and estimates separate slopes for different follow-up time periods, was employed to examine functional improvement patterns. Separate regression slopes were estimated for the zero to twelve-month and the twelve to twenty-four-month periods. The slopes for zero to twelve months showed significant improvement in all measures in the first year. The slopes for twelve to twenty-four months showed deterioration in the scores of the WOMAC pain subscale (slope = 0.67 +/- 0.21, p < 0.01) and function subscale (slope = 1.66 +/- 0.63, p < 0.05), whereas the slopes of the other measures had plateaued. A higher number of comorbidities was consistently the strongest deterrent of functional improvement across measures. The modes of failure of the primary total knee arthroplasty were instrument-specific predictors of outcome (for example, tibial bone lysis affected only the SF-36 physical component score [coefficient = -5.46 +/- 1.91, p < 0.01], while malalignment affected both the SF-36 physical component score [coefficient = 5.41 +/- 2.35, p < 0.05] and the LEAS score [coefficient = 1.42 +/- 0.69, p < 0.05]). Factors related to the surgical technique did not predict

  19. Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.

    PubMed

    Li, Jing-Sheng; Tsai, Tsung-Yuan; Felson, David T; Li, Guoan; Lewis, Cara L

    2017-01-01

    Knee joint pain is a common symptom in obese individuals and walking is often prescribed as part of management programs. Past studies in obese individuals have focused on standing alignment and kinematics in the sagittal and coronal planes. Investigation of 6 degree-of-freedom (6DOF) knee joint kinematics during standing and gait is important to thoroughly understand knee function in obese individuals with knee pain. This study aimed to investigate the 6DOF knee joint kinematics in standing and during gait in obese patients using a validated fluoroscopic imaging system. Ten individuals with obesity and knee pain were recruited. While standing, the knee was in 7.4±6.3°of hyperextension, 2.8±3.3° of abduction and 5.6±7.3° of external rotation. The femoral center was located 0.7±3.1mm anterior and 5.1±1.5mm medial to the tibial center. During treadmill gait, the sagittal plane motion, i.e., flexion/extension and anterior-posterior translation, showed a clear pattern. Specifically, obese individuals with knee pain maintained the knee in more flexion and more anterior tibial translation during most of the stance phase of the gait cycle and had a reduced total range of knee flexion when compared to a healthy non-obese group. In conclusion, obese individuals with knee pain used hyperextension knee posture while standing, but maintained the knee in more flexion during gait with reduced overall range of motion in the 6DOF analysis.

  20. Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait

    PubMed Central

    Li, Jing-Sheng; Tsai, Tsung-Yuan; Felson, David T.; Li, Guoan; Lewis, Cara L.

    2017-01-01

    Knee joint pain is a common symptom in obese individuals and walking is often prescribed as part of management programs. Past studies in obese individuals have focused on standing alignment and kinematics in the sagittal and coronal planes. Investigation of 6 degree-of-freedom (6DOF) knee joint kinematics during standing and gait is important to thoroughly understand knee function in obese individuals with knee pain. This study aimed to investigate the 6DOF knee joint kinematics in standing and during gait in obese patients using a validated fluoroscopic imaging system. Ten individuals with obesity and knee pain were recruited. While standing, the knee was in 7.4±6.3°of hyperextension, 2.8±3.3° of abduction and 5.6±7.3° of external rotation. The femoral center was located 0.7±3.1mm anterior and 5.1±1.5mm medial to the tibial center. During treadmill gait, the sagittal plane motion, i.e., flexion/extension and anterior-posterior translation, showed a clear pattern. Specifically, obese individuals with knee pain maintained the knee in more flexion and more anterior tibial translation during most of the stance phase of the gait cycle and had a reduced total range of knee flexion when compared to a healthy non-obese group. In conclusion, obese individuals with knee pain used hyperextension knee posture while standing, but maintained the knee in more flexion during gait with reduced overall range of motion in the 6DOF analysis. PMID:28339477

  1. Reliability of frames of reference used for tibial component rotation in total knee arthroplasty.

    PubMed

    Page, Stephen R; Deakin, Angela H; Payne, Anthony P; Picard, Frederic

    2011-01-01

    This study evaluated seven different frames of reference used for tibial component rotation in total knee arthroplasty (TKA) to determine which ones showed good reliability between bone specimens. An optoelectronic system based around a computer-assisted surgical navigation system was used to measure and locate 34 individual anatomical landmarks on 40 tibias. Each particular frame of reference was reconstructed from a group of data points taken from the surface of each bone. The transverse axis was used as the baseline to which the other axes were compared, and the differences in angular rotation between the other six reference frames and the transverse axis were calculated. There was high variability in the tibial rotational alignment associated with all frames of reference. Of the references widely used in current TKA procedures, the tibial tuberosity axis and the anterior condylar axis had lower standard deviations (6.1° and 7.3°, respectively) than the transmalleolar axis and the posterior condylar axis (9.3° for both). In conclusion, we found high variability in the frames of reference used for tibial rotation alignment. However, the anterior condylar axis and transverse axis may warrant further tests with the use of navigation. Combining different frames of reference such as the tibial tuberosity axis, anterior condylar axis and transverse axis may reduce the range of errors found in all of these measurements.

  2. Immediate effect of Masai Barefoot Technology shoes on knee joint moments in women with knee osteoarthritis.

    PubMed

    Tateuchi, Hiroshige; Taniguchi, Masashi; Takagi, Yui; Goto, Yusuke; Otsuka, Naoki; Koyama, Yumiko; Kobayashi, Masashi; Ichihashi, Noriaki

    2014-01-01

    Footwear modification can beneficially alter knee loading in patients with knee osteoarthritis. This study evaluated the effect of Masai Barefoot Technology shoes on reductions in external knee moments in patients with knee osteoarthritis. Three-dimensional motion analysis was used to examine the effect of Masai Barefoot Technology versus control shoes on the knee adduction and flexion moments in 17 women (mean age, 63.6 years) with radiographically confirmed knee osteoarthritis. The lateral and anterior trunk lean values, knee flexion and adduction angles, and ground reaction force were also evaluated. The influence of the original walking pattern on the changes in knee moments with Masai Barefoot Technology shoes was evaluated. The knee flexion moment in early stance was significantly reduced while walking with the Masai Barefoot Technology shoes (0.25±0.14Nm/kgm) as compared with walking with control shoes (0.30±0.19 Nm/kgm); whereas the knee adduction moment showed no changes. Masai Barefoot Technology shoes did not increase compensatory lateral and anterior trunk lean. The degree of knee flexion moment in the original walking pattern with control shoes was correlated directly with its reduction when wearing Masai Barefoot Technology shoes by multiple linear regression analysis (adjusted R2=0.44, P<0.01). Masai Barefoot Technology shoes reduced the knee flexion moment during walking without increasing the compensatory trunk lean and may therefore reduce external knee loading in women with knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A study of anatomy of distal femur pertaining to total knee replacement: an analysis, conclusions and recommendations.

    PubMed

    Kumar, K; Sharma, D

    2018-04-01

    Multiple landmarks including the transepicondylar axis (TEA), posterior condylar axis (PCA) and anterior trochlear line (TL) have been used to set up the femoral component rotation, but each is faced with its own practical obstacle that limits its usage. Also a common practice is to set the femoral component rotation at 3° external rotation to PCA and valgus resection angle at 5°-7° to anatomical axis of femur. For the reason that the anatomy of each knee is different, it may not be justified to practice such a set protocol in all cases. The aim of the study was to compare the anatomical landmarks used to set up the femoral component rotation and to study the variability in the different anatomical relationships relevant to total knee replacement. The study had 52 patients (94 knees) with grade IV osteoarthritis. Full-length lower limb scanogram and 1 mm cross-sectional cuts of distal femur were taken. aTEA, sTEA, PCL, TL, CTA, PCA, TLA and valgus angles were taken for all knees. aTEA is identifiable in all cases but sTEA in only 59 knees (62.77%). Correspondingly, CTA is calculable in all knees and PCA in 62.77% cases. Mean CTA and mean PCA were 5.4° ± 1.88° SD and 0.71° ± 1.95° SD, respectively. Mean angle between aTEA and sTEA was 4.88. TL is a line difficult to draw because of high incidence of anterior osteophytes, making CTA a more reliable parameter than TLA. Mean TLA was 10.31° ± 3.52° SD. Mean valgus resection angle was 4.86° ± 2.53° SD. Gender- or side-based differences in any of these values were not statistically different. Using aTEA or sTEA can make a big difference in femoral component rotation; therefore, whether aTEA or sTEA should be used needs to be further investigated. CTA, PCA and valgus resection angle need to be individually calculated for each knee. Use of TLA is not recommended.

  4. Knee joint stabilization therapy in patients with osteoarthritis of the knee: a randomized, controlled trial.

    PubMed

    Knoop, J; Dekker, J; van der Leeden, M; van der Esch, M; Thorstensson, C A; Gerritsen, M; Voorneman, R E; Peter, W F; de Rooij, M; Romviel, S; Lems, W F; Roorda, L D; Steultjens, M P M

    2013-08-01

    To investigate whether an exercise program, initially focusing on knee stabilization and subsequently on muscle strength and performance of daily activities is more effective than an exercise program focusing on muscle strength and performance of daily activities only, in reducing activity limitations in patients with knee osteoarthritis (OA) and instability of the knee joint. A single-blind, randomized, controlled trial involving 159 knee OA patients with self-reported and/or biomechanically assessed knee instability, randomly assigned to two treatment groups. Both groups received a supervised exercise program for 12 weeks, consisting of muscle strengthening exercises and training of daily activities, but only in the experimental group specific knee joint stabilization training was provided. Outcome measures included activity limitations (Western Ontario and McMaster Universities Osteoarthritis Index - WOMAC physical function, primary outcome), pain, global perceived effect and knee stability. Both treatment groups demonstrated large (∼20-40%) and clinically relevant reductions in activity limitations, pain and knee instability, which were sustained 6 months post-treatment. No differences in effectiveness between experimental and control treatment were found on WOMAC physical function (B (95% confidence interval - CI) = -0.01 (-2.58 to 2.57)) or secondary outcome measures, except for a higher global perceived effect in the experimental group (P = 0.04). Both exercise programs were highly effective in reducing activity limitations and pain and restoring knee stability in knee OA patients with instability of the knee. In knee OA patients suffering from knee instability, specific knee joint stabilization training, in addition to muscle strengthening and functional exercises, does not seem to have any additional value. Dutch Trial Register (NTR) registration number: NTR1475. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier

  5. Knee Injuries Are Associated with Accelerated Knee Osteoarthritis Progression: Data from the Osteoarthritis Initiative

    PubMed Central

    Driban, Jeffrey B.; Eaton, Charles B.; Lo, Grace H.; Ward, Robert J.; Lu, Bing; McAlindon, Timothy E.

    2014-01-01

    Objective We aimed to evaluate if a recent knee injury was associated with accelerated knee osteoarthritis (KOA) progression. Methods In the Osteoarthritis Initiative (OAI) we studied participants free of KOA on their baseline radiographs (Kellgren-Lawrence [KL]<2). We compared three groups: 1) individuals with accelerated progression of KOA: defined as having at least one knee that progressed to end-stage KOA (KL Grade 3 or 4) within 48 months, 2) common KOA progression: at least one knee increased in radiographic scoring within 48 months (excluding those defined as accelerated KOA), and 3) no KOA: no change in KL grade in either knee. At baseline, participants were asked if their knees had ever been injured and at each annual visit they were asked about injuries during the prior 12 months. We used multinomial logistic regressions to determine if a new knee injury was associated with the outcome of accelerated KOA or common KOA progression after adjusting for age, sex, body mass index, static knee malalignment, and systolic blood pressure. Results A knee injury during the total observation period was associated with accelerated KOA progression (n=54, odds ratio [OR]=3.14) but not common KOA progression (n=187, OR=1.08). Furthermore, a more recent knee injury (within a year of the outcome) was associated with accelerated (OR=8.46) and common KOA progression (OR=3.12). Conclusion Recent knee injuries are associated with accelerated KOA. Most concerning is that certain injuries may be associated with a rapid cascade towards joint failure in less than one year. PMID:24782446

  6. Internal-external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint.

    PubMed

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by  2° and 4° of internal-external (I-E) malalignment of the femoral component in kinematically aligned total knee arthroplasty. Because I-E malalignment would introduce the greatest changes to the articular surfaces near 90° of flexion, the hypotheses were that the tibial force imbalance would be significantly increased near 90° flexion and that primarily varus-valgus laxity would be affected near 90° flexion. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced I-E malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured from 0° to 120° flexion using a custom tibial force sensor. Bidirectional laxities in four degrees of freedom were measured from 0° to 120° flexion using a custom load application system. Tibial force imbalance increased the greatest at 60° flexion where a regression analysis against the degree of I-E malalignment yielded sensitivities (i.e. slopes) of 30 N/° (medial tibial force > lateral tibial force) and 10 N/° (lateral tibial force > medial tibial force) for internal and external malalignments, respectively. Valgus laxity increased significantly with the 4° external component with the greatest increase of 1.5° occurring at 90° flexion (p < 0.0001). With the tibial component correctly aligned, I-E malalignment of the femoral component caused significant increases in tibial force imbalance. Minimizing I-E malalignment lowers the increase in the tibial force imbalance. By keeping

  7. Computer Assisted Navigation in Knee Arthroplasty

    PubMed Central

    Bae, Dae Kyung

    2011-01-01

    Computer assisted surgery (CAS) was used to improve the positioning of implants during total knee arthroplasty (TKA). Most studies have reported that computer assisted navigation reduced the outliers of alignment and component malpositioning. However, additional sophisticated studies are necessary to determine if the improvement of alignment will improve long-term clinical results and increase the survival rate of the implant. Knowledge of CAS-TKA technology and understanding the advantages and limitations of navigation are crucial to the successful application of the CAS technique in TKA. In this article, we review the components of navigation, classification of the system, surgical method, potential error, clinical results, advantages, and disadvantages. PMID:22162787

  8. Assessing the progress of rehabilitation in patients with ACL reconstruction using the International Knee Documentation Committee Subjective Knee Form

    NASA Astrophysics Data System (ADS)

    Leguizamon, J. H.; Braidot, A.; Catalfamo Formento, P.

    2011-12-01

    There are numerous assessment tools designed to provide information on the results of reconstructive surgery of anterior cruciate ligament (ACL). They are also used for monitoring progress and facilitating clinical decision-making during the rehabilitation process. A brief summary of some existing tools specifically designed to evaluate knee ligament injuries is presented in this article. Then, one of those outcome measures, the International Knee Documentation Committee Subjective Knee Form (IKDC) was applied to a group of patients (N = 10) who had undergone surgery for ACL reconstruction. The patients attended the same physiotherapy service and followed a unified rehabilitation protocol. The assessment was performed twice: four and six months after surgery. The results showed an improvement in the rehabilitation of most patients tested (verified by a difference equal to or greater than 9 points on the IKDC outcome between measurements 1 and 2). The IKDC probed to be an instrument of quick and easy application. It provided quantitative data about the progress of rehabilitation and could be applied in everyday clinical physiotherapy practice. However, the results suggested considering the IKDC as one component of an evaluation kit to make decisions regarding the progress of the rehabilitation treatment.

  9. Is hydroxyapatite a reliable fixation option in unicompartmental knee arthroplasty? A 5- to 13-year experience with the hydroxyapatite-coated unix prosthesis.

    PubMed

    Epinette, Jean-Alain; Manley, Michael T

    2008-10-01

    Hydroxyapatite-coated unicompartmental knee arthroplasty (UKA) is a debatable approach to unicompartmental knee arthritis because UKA isoften viewed as a short-term solution, at best, fora condition that will eventually require a total knee arthroplasty (TKA). Unicompartmental knee arthroplasty is a more technically demanding procedure than TKA, and appropriate patient selection, careful surgical technique, and correct choice of implant geometry are all critical components to its success. A fundamental issue surrounding UKA is whether hydroxyapatite-coated unicompartmental components can provide a long-term solution to unicondylar arthritis. We address this issue in the current study, which is based on a prospective series of 125 hydroxyapatite-coated Unix knee prostheses implanted consecutively between 1994 and 2002, with a 5-year minimum follow-up and a 13-year maximum follow-up. The results of our study indicate that uncemented hydroxyapatite-coated UKA can be successful in the long term.

  10. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  11. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  12. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  13. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femoral (hemi-knee) metallic uncemented prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint...

  14. The Effects of Common Footwear on Joint Loading in Osteoarthritis of the Knee

    PubMed Central

    Shakoor, Najia; Sengupta, Mondira; Foucher, Kharma C.; Wimmer, Markus A.; Fogg, Louis F.; Block, Joel A.

    2010-01-01

    Objective Elevated joint loads during walking have been associated with the severity and progression of osteoarthritis (OA) of the knee. Footwear may have the potential to alter these loads. This study compared the effects of several common shoe types on knee loading in subjects with OA of the knee. Methods 31 subjects (10 men, 21 women) with radiographic and symptomatic knee OA underwent gait analyses using an optoelectronic camera system and multi-component force plate. In each case, gait was evaluated barefoot and while wearing 4 different shoes: 1) clogs (Dansko®), 2) stability shoes (Brooks Addiction®), 3) flat walking shoes (Puma H Street®), and 4) flip-flops. Peak knee loads were compared between the different footwear conditions. Results Overall, the clogs and stability shoes, resulted in a significantly higher peak knee adduction moment (3.1±0.7 and 3.0±0.7 %BW*ht, respectively, ~15% higher, p<0.05)) compared with that of flat walking shoes (2.8±0.7%BW*ht), flip-flops (2.7±0.8%BW*ht) and barefoot walking (2.7±0.7%BW*ht). There were no statistically significant differences in knee loads with the flat walking shoes and flip-flops compared to barefoot walking. Conclusions These data confirm that footwear may have significant effects on knee loads during walking in subjects with OA of the knee. Flexibility and heel height may be important differentiating characteristics of shoes which affect knee loads. In light of the strong relationship between knee loading and OA, the design and biomechanical effects of modern footwear should be more closely evaluated in terms of their effects on the disease. PMID:20191571

  15. Position controlled Knee Rehabilitation Orthotic Device for Patients after Total Knee Replacement Arthroplasty

    NASA Astrophysics Data System (ADS)

    Wannaphan, Patsiri; Chanthasopeephan, Teeranoot

    2016-11-01

    Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.

  16. Total knee arthroplasty for the management of joint destruction in tuberculous arthritis.

    PubMed

    Oztürkmen, Yusuf; Uzümcügil, Onat; Karamehmetoğlu, Mahmut; Leblebici, Cem; Caniklioğlu, Mustafa

    2014-05-01

    .6 ± 7.7 points (p < 0.05). Ten knees showed good integrity, and no radiolucent lines were found in the bone-prosthesis interface in relation to any component. Radiolucent lines were apparent on the tibial side in two knees. They were less than 1 mm thick and non-progressive, and clinically, there was no evidence of loosening of the component. Culture specimens were positive for five patients. TKA is a safe procedure for tuberculous arthritis with recent onset providing symptomatic relief, functional improvement and early return to activity when performed in correct time. A long disease-free interval should not be a prerequisite for arthroplasty. Wide surgical debridement is the mainstay to eradicate the disease, and post-operative antituberculous chemotherapy controls the residual foci. IV.

  17. Arthrodesis of the knee after failed knee replacement.

    PubMed

    Wade, P J; Denham, R A

    1984-05-01

    Arthrodesis of the knee is sometimes needed for failed total knee replacement, but fusion can be difficult to obtain. We describe a method of arthrodesis that uses the simple, inexpensive, Portsmouth external fixator. Bony union was obtained in all six patients treated with this technique. These results are compared with those obtained by other methods of arthrodesis.

  18. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    PubMed

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  19. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties.

    PubMed

    Martin, Audrey J; Seagers, Kirsten A; Van Citters, Douglas W

    2017-07-01

    Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P < .05). The median volumetric material loss and the maximum linear depth for the total population were -0.23 mm 3 and 5.84 μm, respectively. CoCr components in mixed metal junctions had higher maximum linear depth (P = .007) than corresponding Ti components. Fretting scores of Ti6Al4V alloy components in mixed metal junctions were statistically higher than the remaining groups. Taper angle did not correlate with material loss. Results suggest that CoCr components in mixed metal junctions are more vulnerable to corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. MULTIPLE NONSPECIFIC SITES OF JOINT PAIN OUTSIDE THE KNEES DEVELOP IN PERSONS WITH KNEE PAIN

    PubMed Central

    Felson, David T.; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara; Lewis, Cora E.; Law, Laura Frey; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-01-01

    Objective Many persons with knee pain have joint pain outside the knee but despite the impact and high frequency of this pain, its distribution and causes have not been studied. Those studying gait abnormalities have suggested that knee pain causes pain in adjacent joints but pain adaptation strategies are highly individualized. Methods We studied persons age 50-79 years with or at high risk of knee osteoarthritis drawn from two community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative and followed for 5-7 years. We excluded those with knee pain at baseline and compared those who developed and did not develop knee pain at the first follow-up examination (the index visit). We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint specific pain adjusted for age, sex, BMI, depression with sensitivity analyses excluding those with widespread pain. Results In the combined cohorts, there were 693 persons with index visit knee pain vs. 2793 without it. 79.6% of those with bilateral and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee vs. 49.9% of those without knee pain. An increased risk of pain was present in most extremity joint sites without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Conclusions Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. PMID:27589036

  1. The effects of knee direction, physical activity and age on knee joint position sense.

    PubMed

    Relph, Nicola; Herrington, Lee

    2016-06-01

    Previous research has suggested a decline in knee proprioception with age. Furthermore, regular participation in physical activity may improve proprioceptive ability. However, there is no large scale data on uninjured populations to confirm these theories. The aim of this study was to provide normative knee joint position data (JPS) from healthy participants aged 18-82years to evaluate the effects of age, physical activity and knee direction. A sample of 116 participants across five age groups was used. The main outcome measures were knee JPS absolute error scores into flexion and extension, Tegner activity levels and General Practitioner Physical Activity Questionnaire results. Absolute error scores in to knee flexion were 3.6°, 3.9°, 3.5°, 3.7° and 3.1° and knee extension were 2.7°, 2.5°, 2.9°, 3.4° and 3.9° for ages 15-29, 30-44, 45-59, 60-74 and 75 years old respectively. Knee extension and flexion absolute error scores were significantly different when age group data were pooled. There was a significant effect of age and activity level on joint position sense into knee extension. Age and lower Tegner scores were also negatively correlated to joint position sense into knee extension. The results provide some evidence for a decline in knee joint position sense with age. Further, active populations may have heightened static proprioception compared to inactive groups. Normative knee joint position sense data is provided and may be used by practitioners to identify patients with reduced proprioceptive ability. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. The effects of geometric uncertainties on computational modelling of knee biomechanics

    PubMed Central

    Fisher, John; Wilcox, Ruth

    2017-01-01

    The geometry of the articular components of the knee is an important factor in predicting joint mechanics in computational models. There are a number of uncertainties in the definition of the geometry of cartilage and meniscus, and evaluating the effects of these uncertainties is fundamental to understanding the level of reliability of the models. In this study, the sensitivity of knee mechanics to geometric uncertainties was investigated by comparing polynomial-based and image-based knee models and varying the size of meniscus. The results suggested that the geometric uncertainties in cartilage and meniscus resulting from the resolution of MRI and the accuracy of segmentation caused considerable effects on the predicted knee mechanics. Moreover, even if the mathematical geometric descriptors can be very close to the imaged-based articular surfaces, the detailed contact pressure distribution produced by the mathematical geometric descriptors was not the same as that of the image-based model. However, the trends predicted by the models based on mathematical geometric descriptors were similar to those of the imaged-based models. PMID:28879008

  3. The effects of geometric uncertainties on computational modelling of knee biomechanics

    NASA Astrophysics Data System (ADS)

    Meng, Qingen; Fisher, John; Wilcox, Ruth

    2017-08-01

    The geometry of the articular components of the knee is an important factor in predicting joint mechanics in computational models. There are a number of uncertainties in the definition of the geometry of cartilage and meniscus, and evaluating the effects of these uncertainties is fundamental to understanding the level of reliability of the models. In this study, the sensitivity of knee mechanics to geometric uncertainties was investigated by comparing polynomial-based and image-based knee models and varying the size of meniscus. The results suggested that the geometric uncertainties in cartilage and meniscus resulting from the resolution of MRI and the accuracy of segmentation caused considerable effects on the predicted knee mechanics. Moreover, even if the mathematical geometric descriptors can be very close to the imaged-based articular surfaces, the detailed contact pressure distribution produced by the mathematical geometric descriptors was not the same as that of the image-based model. However, the trends predicted by the models based on mathematical geometric descriptors were similar to those of the imaged-based models.

  4. Polyethylene Wear in Retrieved Reverse Total Shoulder Components

    PubMed Central

    Day, Judd S; MacDonald, Daniel W; Olsen, Madeline; Getz, Charles; Williams, Gerald R; Kurtz, Steven M

    2011-01-01

    Background Reverse total shoulder arthroplasty has been used to treat rotator cuff tear arthropathy, proximal humeral fractures and for failed conventional total shoulder prostheses. It has been suggested that polyethylene wear is potentially higher in reverse shoulder replacements than in conventional shoulder replacements. The modes and degree of polyethylene wear have not been completely elucidated. The purpose of this study was to evaluate polyethylene wear patterns in seven specimens retrieved at revision arthroplasty and identify factors that may be associated with increased wear. Methods Reverse total shoulder components were retrieved from 7 patients during revision arthroplasty for loosening and/or pain. Pre-operative glenoid tilt and placement, and scapular notching were evaluated using pre-operative radiographs. Polyethylene wear was evaluated using microCT and optical microscopy. Results Wear on the rim of the polyethylene humeral cup, was identified on all retrieved components. The extent of rim wear varied from a penetration depth of 0.1 to 4.7 mm. We could not demonstrate a correlation between scapular notching and rim wear. However, rim wear was more extensive when the inferior screw had made contact with the liner. Metal on metal wear between the humeral component and the inferior screw of one component was also observed. Wear of the intended bearing surface was minimal. Discussion Rim damage was the predominant cause of polyethylene wear in our retrieved specimens. Direct contact between the humeral component and inferior metaglene screws is concerning because this could lead to accelerated UHMWPE wear and also induce mechanical loosening of the glenoid component. PMID:21724419

  5. The influence of knee pain location on symptoms, functional status and knee-related quality of life in older adults with chronic knee pain: data from the Osteoarthritis Initiative

    PubMed Central

    Farrokhi, Shawn; Chen, Yi-Fan; Piva, Sara R.; Fitzgerald, G. Kelley; Jeong, Jong-Hyeon; Kwoh, C. Kent

    2015-01-01

    Objective To evaluate whether knee pain location can influence symptoms, functional status and knee-related quality of life in older adults with chronic knee pain. Methods A total of 2959 painful knees from the Osteoarthritis Initiative database were analyzed. Trained interviewers recorded patient-reported location of knee pain. Painful knees were divided into three groups of patellofemoral only pain, tibiofemoral only pain, and combined pain. Self-reported knee-specific symptoms, functional status and knee-related quality of life were assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS). Results The most common knee pain pattern was tibiofemoral only pain (62%), followed by patellofemoral only pain (23%) and combined pain (15%). The combined pain pattern was associated with greater odds of reporting pain, symptoms, sports or recreational activity limitations and lower knee-related quality of life compared to either isolated knee pain patterns, after adjusting for demographics and radiographic disease severity. Individual item analysis further revealed that patients with combined pain had greater odds of reporting difficulty with daily weightbearing activities that required knee bending compared to tibiofemoral or patellofemoral only pain patterns. Furthermore, symptoms, functional status, and knee-related quality of life were comparable between patients with patellofemoral and tibiofemoral only pain patterns, after adjusting for demographics and radiographic disease severity. Discussion Combined patellofemoral and tibiofemoral pain is associated with poorer clinical presentation compared to isolated knee pain from either location. Additionally, patellofemoral pain in isolation may be as important as tibiofemoral pain in causing symptoms and functional limitation in older adults with chronic knee pain. PMID:26308705

  6. Tibial component coverage based on bone mineral density of the cut tibial surface during unicompartmental knee arthroplasty: clinical relevance of the prevention of tibial component subsidence.

    PubMed

    Lee, Yong Seuk; Yun, Ji Young; Lee, Beom Koo

    2014-01-01

    An optimally implanted tibial component during unicompartmental knee arthroplasty would be flush with all edges of the cut tibial surface. However, this is often not possible, partly because the tibial component may not be an ideal shape or because the ideal component size may not be available. In such situations, surgeons need to decide between component overhang and underhang and as to which sites must be covered and which sites could be undercovered. The objectives of this study were to evaluate the bone mineral density of the cut surface of the proximal tibia around the cortical rim and to compare the bone mineral density according to the inclusion of the cortex and the site-specific matched evaluation. One hundred and fifty consecutive patients (100 men and 50 women) were enrolled in this study. A quantitative computed tomography was used to determine the bone density of the cut tibial surface. Medial and lateral compartments were divided into anterior, middle, and posterior regions, and these three regions were further subdivided into two regions according to containment of cortex. The site-specific matched comparison (medial vs. lateral) of bone mineral density was performed. In medial sides, the mid-region, including the cortex, showed the highest bone mineral density in male and female patients. The posterior region showed the lowest bone mineral density in male patients, and the anterior and posterior regions showed the lowest bone mineral density in female patients. Regions including cortex showed higher bone mineral density than pure cancellous regions in medial sides. In lateral sides, posterior regions including cortex showed highest bone mineral density with statistical significance in both male and female patients. The anterior region showed the lowest bone mineral density in both male and female patients. The mid-region of the medial side and the posterior region of the lateral side are relatively safe without cortical coverage when the component

  7. Custom-fit total knee arthroplasty: our initial experience in 32 knees.

    PubMed

    Bali, Kamal; Walker, Peter; Bruce, Warwick

    2012-06-01

    We share our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 32 TKAs from May 2010 to March 2011. Ten of these patients had prior TKA done on the other side using conventional or navigation-assisted TKA. Customized cutting blocks were generated for each of the knee using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 6 weeks, long-leg radiographs were obtained to evaluate the coronal alignment. There were no adverse intraoperative events. Twenty-nine of the 32 knees had a mechanical axis restored to within 3°° of neutral. Of 10 patients with prior TKA without custom-fit technology, the mean blood loss and the mean skin-to-skin time was found to be lower in knees that had undergone custom-fit TKA. We conclude that this technology can be safely used in most of the cases of osteoarthritis. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Multiple Nonspecific Sites of Joint Pain Outside the Knees Develop in Persons With Knee Pain.

    PubMed

    Felson, David T; Niu, Jingbo; Quinn, Emily K; Neogi, Tuhina; Lewis, Cara L; Lewis, Cora E; Frey Law, Laura; McCulloch, Chuck; Nevitt, Michael; LaValley, Michael

    2017-02-01

    Many persons with knee pain have joint pain outside the knee, but despite the impact and high frequency of this pain, its distribution and causes have not been studied. We undertook this study to test the hypothesis of those studying gait abnormalities who have suggested that knee pain causes pain in adjacent joints but that pain adaptation strategies are highly individualized. We studied persons ages 50-79 years with or at high risk of knee osteoarthritis who were recruited from 2 community-based cohorts, the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative, and we followed them up for 5-7 years. We excluded those with knee pain at baseline and compared those who had developed knee pain at the first follow-up examination (the index visit) with those who had not. We examined pain on most days at joint regions outside the knee in examinations after the index visit. Logistic regression analyses examined the risk of joint-specific pain adjusted for age, sex, body mass index, and symptoms of depression, and we performed sensitivity analyses excluding those with widespread pain. In the combined cohorts, 693 persons had knee pain at the index visit and 2,793 did not. A total of 79.6% of those with bilateral knee pain and 63.8% of those with unilateral knee pain had pain during follow-up in a joint region outside the knee, compared with 49.9% of those without knee pain. There was an increased risk of pain at most extremity joint sites, without a predilection for specific sites. Results were unchanged when those with widespread pain were excluded. Persons with chronic knee pain are at increased risk of pain in multiple joints in no specific pattern. © 2016, American College of Rheumatology.

  9. Normal axial alignment of the lower extremity and load-bearing distribution at the knee.

    PubMed

    Hsu, R W; Himeno, S; Coventry, M B; Chao, E Y

    1990-06-01

    Based on a series of 120 normal subjects of different gender and age, the geometry of the knee joint was analyzed using a full-length weight-bearing roentgenogram of the lower extremity. A special computer program based on the theory of a rigid body spring model was applied to calculate the important anatomic and biomechanical factors of the knee joint. The tibiofemoral mechanical angle was 1.2 degrees varus. Hence, it is difficult to rationalize the 3 degree varus placement of the tibial component in total knee arthroplasty suggested by some authors. The distal femoral anatomic valgus (measured from the lower one-half of the femur) was 4.2 degrees in reference to its mechanical axis. This angle became 4.9 degrees when the full-length femoral anatomic axis was used. When simulating a one-legged weight-bearing stance by shifting the upper-body gravity closer to the knee joint, 75% of the knee joint load passed through the medial tibial plateau. The knee joint-line obliquity was more varus in male subjects. The female subjects had a higher peak joint pressure and a greater patello-tibial Q angle. Age had little effect on the factors relating to axial alignment of the lower extremity and load transmission through the knee joint.

  10. Resistance Exercise for Knee Osteoarthritis

    PubMed Central

    Vincent, Kevin R.; Vincent, Heather K.

    2013-01-01

    The initiation, progression, and severity of knee osteoarthritis (OA) has been associated with decreased muscular strength and alterations in joint biomechanics. Chronic OA pain may lead to anxiety, depression, fear of movement, and poor psychological outlook. The fear of movement may prevent participation in exercise and social events which could lead to further physical and social isolation. Resistance exercise (RX) has been shown to be an effective intervention both for decreasing pain and for improving physical function and self-efficacy. RX may restore muscle strength and joint mechanics while improving physical function. RX may also normalize muscle firing patterns and joint biomechanics leading to reductions in joint pain and cartilage degradation. These physical adaptations could lead to improved self-efficacy and decreased anxiety and depression. RX can be prescribed and performed by patients across the OA severity spectrum. When designing and implementing an RX program for a patient with knee OA, it is important to consider both the degree of OA severity as well as the level of pain. RX, either in the home or at a fitness facility, is an important component of a comprehensive regimen designed to offset the physical and psychological limitations associated with knee OA. Unique considerations for this population include: 1) monitoring pain during and after exercise, 2) providing days of rest when disease flares occur, and 3) infusing variety into the exercise regimen to encourage adherence. PMID:22632702

  11. Astym® Therapy for the Management of Recalcitrant Knee Joint Stiffness after Total Knee Arthroplasty.

    PubMed

    Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A

    2016-01-01

    Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.

  12. Knee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty

    PubMed Central

    Rodriguez-Merchan, E. Carlos

    2015-01-01

    Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients after a failed two-stage reimplantation. A PubMed search related to the resolution of infection by means of an above-the-knee amputation (AKA) or a knee fusion was performed until 10 January 2015. The key words were: infected TKA and above-the-knee amputation. Five hundred and sixty-six papers were found, of which ten were reviewed because they were focused on the topic of the article. KF should be strongly considered as the treatment of choice for patients who have persistent infected TKA after a failed two-stage revision arthroplasty. Patients can walk at least inside the house, and activity of daily living independence is achieved by the patients with successful KF, although walking aids, including a shoe lift, are required. An intramedullary nail leads to better functional results than an external fixator. The functional outcome after AKA performed after TKA is poor. A substantial percentage of the patients never fit with a prosthesis, and those who are seldom obtain functional independence. Only 50% of patients are able to walk after AKA. Patients receiving KF for treating recurrent PJI after TKA have better function and ambulatory status compared to patients receiving AKA. KF must be recommended as the treatment of choice for patients who have persistent infected TKA after a failed two-stage reimplantation procedure. PMID:26550586

  13. Knee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty.

    PubMed

    Rodriguez-Merchan, E Carlos

    2015-10-01

    Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients after a failed two-stage reimplantation. A PubMed search related to the resolution of infection by means of an above-the-knee amputation (AKA) or a knee fusion was performed until 10 January 2015. The key words were: infected TKA and above-the-knee amputation. Five hundred and sixty-six papers were found, of which ten were reviewed because they were focused on the topic of the article. KF should be strongly considered as the treatment of choice for patients who have persistent infected TKA after a failed two-stage revision arthroplasty. Patients can walk at least inside the house, and activity of daily living independence is achieved by the patients with successful KF, although walking aids, including a shoe lift, are required. An intramedullary nail leads to better functional results than an external fixator. The functional outcome after AKA performed after TKA is poor. A substantial percentage of the patients never fit with a prosthesis, and those who are seldom obtain functional independence. Only 50% of patients are able to walk after AKA. Patients receiving KF for treating recurrent PJI after TKA have better function and ambulatory status compared to patients receiving AKA. KF must be recommended as the treatment of choice for patients who have persistent infected TKA after a failed two-stage reimplantation procedure.

  14. Cosmic ray energy spectrum around the knee obtained by the Tibet Experiment and future prospects

    NASA Astrophysics Data System (ADS)

    Katayose, Yusaku

    The measurement of the energy spectrum and the chemical composition of cosmic rays at the 'Knee' energy region have been made in the Tibet-AS experiment since 1990. The 1st phase of the Tibet hybrid experiment(1996-1999) consisted of Tibet II air-shower array(AS), Emulsion Chamber(EC) and burst detector(BD). The EC was used to detect high energy-gamma-families of the energy greater than 20 TeV at the core of ASs of which more than 80% are induced by light nuclei like protons or helium. Due to the high spatial resolution of the EC, proton and helium events were separated from others and we obtained the energy spectrum of each of them using 177 family events. We also obtained all-particle energy spectrum of primary cosmic rays in a wide range from 1014 eV to 1017 eV by the Tibet-III air-shower array. The size spectrum exhibits a sharp knee at a corresponding primary energy around 4 PeV. These results strongly indicated that the fraction of the light component to the all particle spectrum is decreasing around the knee.The observation of the AS core has been continued with upgraded Tibet III array and burst detectors without using X-ray films, which still works as the selector for the air showers induced by light component (pHe). This second phase experiment shows that the dominance of the heavy elements at the knee reported by the first phase experiment is confirmed with higher statistics by one order.Our results suggest that the main component at the knee is heavy elements (heavier than helium) because of the low intensities of observed proton and helium fluxes, whose summed flux are less than 30% of all particles. A new air-shower-core detector(YAC) will be added to the Tibet AS array to explicitly measure the heavy elements around the knee and beyond. In this paper, the results of composition study with the Tibet experiment are summarized and the prospects for the next phase experiment are described.

  15. The associations between quadriceps muscle strength, power, and knee joint mechanics in knee osteoarthritis: A cross-sectional study.

    PubMed

    Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A

    2015-12-01

    Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (P<0.05). Quadriceps power at 90% of one repetition maximum accounted for 9% of the variance in peak knee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. [Mixed knee arthrodesis a rescue alternative in knee periprosthetic joint infection].

    PubMed

    López-Cervantes, Roberto Enrique; Rivera-Villa, Adrián Huematzin; Miguel-Pérez, Adrián; Morales-de Los Santos, René; Torres-González, Rubén; Pérez-Atanasio, José Manuel

    2016-01-01

    Knee arthrodesis is a rescue procedure for patients with knee periprosthetic joint infection who are not candidates for a revision surgery. The actual methods present a high complication rate with only moderate efectivity. We retrospectively analyzed 17 cases, of patients with knee periprosthetic joint infection and bone loss treated by intramedular expandable nail and monoplanar external fixator with a mínimum evolution of 1 year, evaluating the medical records and digitalized X-rays by 2 sub specialized doctors in osteoarticular rescue surgery. From the 17 patients, 88.2% were classified as Anderson Orthopaedic Research Institute classification grade (III) and the 11.2% IIB. We obtained fusion in 82.5%, staged Hammer (I-II) in a mean time of 6.33 months. Achieving independent gait was reported in 88.2%. Our complication rate was 47.1%, most of them minor complications except for a supracondylar amputation. Our infection recurrence rate was 35.4%. Mean intervention rate was 2.47 surgeries, all without any operative room complication. We achieved a fusion rate similar to other available knee arthrodesis methods in a similar treatment time; with lower complication rate, making it a suitable rescue alternative for knee arthrodesis in patients with significant bone loss and knee periprosthetic joint infection.

  17. Associations of knee muscle force, bone malalignment, and knee-joint laxity with osteoarthritis in elderly people.

    PubMed

    Nakagawa, Kazumasa; Maeda, Misako

    2017-03-01

    [Purpose] From the viewpoint of prevention of knee osteoarthritis, the aim of this study was to verify how muscle strength and joint laxity are related to knee osteoarthritis. [Subjects and Methods] The study subjects consisted of 90 community-dwelling elderly people aged more than 60 years (22 males, 68 females). Femorotibial angle alignment, knee joint laxity, knee extensors and flexor muscle strengths were measured in all subjects. In addition, the subjects were divided into four groups based on the presence of laxity and knee joint deformation, and the muscle strength values were compared. [Results] There was no significant difference in knee extensor muscle strength among the four groups. However, there was significant weakness of the knee flexor muscle in the group with deformation and laxity was compared with the group without deformation and laxity. [Conclusion] Decreased knee flexor muscle strengths may be involved in knee joint deformation. The importance of muscle strength balance was also considered.

  18. Effect of subjective knee-joint pain on the laterality of knee extension strength and gait in elderly women.

    PubMed

    Sugiura, Hiroki; Demura, Shinichi

    2012-01-01

    This study aimed to examine the effect of subjective knee-joint pain on the laterality of knee extension strength and gait in elderly women. The subjects were 144 elderly women (62-94 years old; mean age 76.2±6.0 years; ±S.D.) who were divided into the following groups: 81 persons without knee-pain (no knee-pain group), 39 persons with the subjective pain in right or left knee (single knee-pain group), and 24 persons with the subjective pain in both knees (double knee-pain group). The subjects took a knee extension strength test and a 12 m maximum effort walk test. Knee extension strength, stance time, swing time, stride length, step length and swing speed were selected as parameters. A significant laterality was found in knee extension strength only in the one knee-pain group. The laterality of gait parameters was not found in all groups. In conclusion, elderly women who can perform daily living activity independently, even though having subjective pain in either knee or laterality in knee extension strength exertion show little laterality of gait during short distance walking. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. The integrity of welded interfaces in ultra-high molecular weight polyethylene: Part 2--interface toughness.

    PubMed

    Haughie, David W; Buckley, C Paul; Wu, Junjie

    2006-07-01

    In Part 2 of a study of welding of ultra-high molecular weight polyethylene (UHMWPE), experiments were conducted to measure the interfacial fracture energy of butt welds, for various welding times and temperatures above the melting point. Their toughness was investigated at 37 degrees C in terms of their fracture energy, obtained by adapting the essential work of fracture (EWF) method. However, a proportion of the welded samples (generally decreasing with increasing welding time or temperature) failed in dual ductile/brittle mode, hence invalidating the EWF test. Even those failing in purely ductile mode showed a measurable interface work of fracture only for the highest weld temperature and time: 188 degrees C and 90 min. Results from the model presented in Part 1 show that this corresponds to the maximum reptated molecular weight reaching close to the peak in the molar mass distribution. Hence this work provides the first experimental evidence that the slow rate of self-diffusion in UHMWPE leads to welded interfaces acting as low-toughness crack paths. Since such interfaces exist around every powder particle in processed UHMWPE this problem cannot be avoided, and it must be accommodated in design of hip and knee bearing surfaces made from this polymer.

  20. In vitro wear assessment of the Charité Artificial Disc according to ASTM recommendations.

    PubMed

    Serhan, Hassan A; Dooris, Andrew P; Parsons, Matthew L; Ares, Paul J; Gabriel, Stefan M

    2006-08-01

    Biomechanical laboratory research. To evaluate the potential for Ultra High Molecular Weight Polyethylene (UHMWPE) wear debris from the Charité Artificial Disc. Cases of osteolysis from artificial discs are extremely rare, but hip and knee studies demonstrate the osteolytic potential and clinical concern of UHMWPE wear debris. Standards for testing artificial discs continue to evolve, and there are few detailed reports of artificial disc wear characterizations. Implant assemblies were tested to 10 million cycles of +/- 7.5 degrees flexion-extension or +/- 7.5 degrees left/right lateral bending, both with +/- 2 degrees axial rotation and 900 N to 1,850 N cyclic compression. Cores were weighed, measured, and photographed. Soak and loaded soak controls were used. Wear debris was analyzed via scanning electron microscopy and particle counters. The average total wear of the implants was 0.11 and 0.13 mg per million cycles, before and after accounting for serum absorption, respectively. Total height loss was approximately 0.2 mm. Wear debris ranged from submicron to > 10 microm in size. Under these test conditions, the Charité Artificial Disc produced minimal wear debris. Debris size and morphology tended to be similar to other CoCr-UHMWPE joints. More testing is necessary to evaluate the implants under a spectrum of loading conditions.

  1. Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.

    PubMed

    Firkins, P; Hailey, J L; Fisher, J; Lettington, A H; Butter, R

    1998-10-01

    The wear of ultra-high molecular weight polyethylene (UHMWPE) in artificial joints and the resulting wear debris-induced osteolysis remains a major clinical concern in the orthopaedic sector. Third-body damage of metallic femoral heads is often cited as a cause of accelerated polyethylene wear, and the use of ceramic femoral heads in the hip is gaining increasing favour. In the knee prostheses and for smaller diameter femoral heads, the application of hard surface coatings, such as diamond-like carbon, is receiving considerable attention. However, to date, there has been little or no investigation of the tribology of these coatings in simulated biological environments. In this study, diamond-like carbon (DLC) has been compared to stainless steel in its undamaged form and following simulated third-body damage. The wear of UHMWPE was found to be similar when sliding against undamaged DLC and stainless steel counterfaces. DLC was found to be much more damage resistant than DLC. Under test conditions that simulate third-body damage to the femoral head, the wear of UHMWPE was seven times lower against DLC than against stainless steel (P < 0.05). The study shows DLC has considerable potential as a femoral bearing surface in artificial joints.

  2. Preoperative Pain Neuroscience Education Combined With Knee Joint Mobilization for Knee Osteoarthritis: A Randomized Controlled Trial.

    PubMed

    Lluch, Enrique; Dueñas, Lirios; Falla, Deborah; Baert, Isabel; Meeus, Mira; Sánchez-Frutos, José; Nijs, Jo

    2018-01-01

    This study aimed to first compare the effects of a preoperative treatment combining pain neuroscience education (PNE) with knee joint mobilization versus biomedical education with knee joint mobilization on central sensitization (CS) in patients with knee osteoarthritis, both before and after surgery. Second, we wanted to compare the effects of both interventions on knee pain, disability, and psychosocial variables. Forty-four patients with knee osteoarthritis were allocated to receive 4 sessions of either PNE combined with knee joint mobilization or biomedical education with knee joint mobilization before surgery. All participants completed self-administered questionnaires and quantitative sensory testing was performed at baseline, after treatment and at a 1 month follow-up (all before surgery), and at 3 months after surgery. Significant and clinically relevant differences before and after surgery were found after treatments for both knee pain and disability, and some measures of CS (ie, widespread hyperalgesia, CS inventory), with no significant between-group differences. Other indicators of CS (ie, conditioned pain modulation, temporal summation) did not change over time following either treatment, and in some occasions the observed changes were not in the expected direction. Patients receiving PNE with knee joint mobilization achieved greater improvements in psychosocial variables (pain catastrophizing, kinesiophobia) both before and after surgery. Preoperative PNE combined with knee joint mobilization did not produce any additional benefits over time for knee pain and disability, and CS measures compared with biomedical education with knee joint mobilization. Superior effects in the PNE with knee joint mobilization group were only observed for psychosocial variables related to pain catastrophizing and kinesiophobia.

  3. TOTAL KNEE REPLACEMENT IN PATIENTS WITH BELOW-KNEE AMPUTATION

    PubMed Central

    Karam, Matthew D; Willey, Michael; Shurr, Donald G

    2010-01-01

    Total knee replacement (TKR) is reserved for patients with severe and disabling arthritis that is non-responsive to conservative measures. Based on existing data, total knee replacement is a safe and cost-effective treatment for alleviating pain and improving physical function in patients who do not respond to conservative therapy. Despite the large variation in health status of patients and types of prosthesis implanted, total knee replacement has proven to be a relatively low risk and successful operation. Each year in the United States surgeons perform approximately 300,000 TKR.1 Likewise, lower extremity amputation is commonly performed in the United States with an annual incidence of 110,000 per year.2 Nearly 70% of all lower extremity amputations are performed as the result of chronic vascular disease, followed by trauma (22%), congenital etiology and tumor (4% each).3 Approximately 50% of all lower extremity amputations are performed secondary to complications from Diabetes Mellitus. Norvell et al. demonstrated that patients who have previously undergone transtibial amputation and ambulate with a prosthesis are more likely to develop degenerative joint disease in the con-tralateral extremity than the ipsilateral extremity.4 Further, radiographic changes consistent with osteoporosis have been demonstrated in up to 88% of limbs that have undergone transtibial amputation.8 To our knowledge, there have been only three reported cases of total knee replacement in patients with ipsilateral transtibial amputation.5,7 The purpose of the present study is to review the existing data on total knee replacement in patients who have undergone transtibial amputation. Further we present a patient with a transtibial amputation who underwent contralateral total knee replacement. PMID:21045987

  4. Injury risk curves for the skeletal knee-thigh-hip complex for knee-impact loading.

    PubMed

    Rupp, Jonathan D; Flannagan, Carol A C; Kuppa, Shashi M

    2010-01-01

    Injury risk curves for the skeletal knee-thigh-hip (KTH) relate peak force applied to the anterior aspect of the flexed knee, the primary source of KTH injury in frontal motor-vehicle crashes, to the probability of skeletal KTH injury. Previous KTH injury risk curves have been developed from analyses of peak knee-impact force data from studies where knees of whole cadavers were impacted. However, these risk curves either neglect the effects of occupant gender, stature, and mass on KTH fracture force, or account for them using scaling factors derived from dimensional analysis without empirical support. A large amount of experimental data on the knee-impact forces associated with KTH fracture are now available, making it possible to estimate the effects of subject characteristics on skeletal KTH injury risk by statistically analyzing empirical data. Eleven studies were identified in the biomechanical literature in which the flexed knees of whole cadavers were impacted. From these, peak knee-impact force data and the associated subject characteristics were reanalyzed using survival analysis with a lognormal distribution. Results of this analysis indicate that the relationship between peak knee-impact force and the probability of KTH fracture is a function of age, total body mass, and whether the surface that loads the knee is rigid. Comparisons between injury risk curves for the midsize adult male and small adult female crash test dummies defined in previous studies and new risk curves for these sizes of occupants developed in this study suggest that previous injury risk curves generally overestimate the likelihood of KTH fracture at a given peak knee-impact force. Future work should focus on defining the relationships between impact force at the human knee and peak axial compressive forces measured by load cells in the crash test dummy KTH complex so that these new risk curves can be used with ATDs.

  5. Effect of an ankle-foot orthosis on knee joint mechanics: a novel conservative treatment for knee osteoarthritis.

    PubMed

    Fantini Pagani, Cynthia H; Willwacher, Steffen; Benker, Rita; Brüggemann, Gert-Peter

    2014-12-01

    Several conservative treatments for medial knee osteoarthritis such as knee orthosis and laterally wedged insoles have been shown to reduce the load in the medial knee compartment. However, those treatments also present limitations such as patient compliance and inconsistent results regarding the treatment success. To analyze the effect of an ankle-foot orthosis on the knee adduction moment and knee joint alignment in the frontal plane in subjects with knee varus alignment. Controlled laboratory study, repeated measurements. In total, 14 healthy subjects with knee varus alignment were analyzed in five different conditions: without orthotic, with laterally wedged insoles, and with an ankle-foot orthosis in three different adjustments. Three-dimensional kinetic and kinematic data were collected during gait analysis. Significant decreases in knee adduction moment, knee lever arm, and joint alignment in the frontal plane were observed with the ankle-foot orthosis in all three different adjustments. No significant differences could be found in any parameter while using the laterally wedged insoles. The ankle-foot orthosis was effective in reducing the knee adduction moment. The decreases in this parameter seem to be achieved by changing the knee joint alignment and thereby reducing the knee lever arm in the frontal plane. This study presents a novel approach for reducing the load in the medial knee compartment, which could be developed as a new treatment option for patients with medial knee osteoarthritis. © The International Society for Prosthetics and Orthotics 2013.

  6. Biomechanical comparison of the strength of adhesion of polymethylmethacrylate cement to zirconia ceramic and cobalt-chromium alloy components in a total knee arthroplasty.

    PubMed

    Kumahashi, Nobuyuki; Uchio, Yuji; Kitamura, Nobuto; Satake, Shigeru; Iwamoto, Mikio; Yasuda, Kazunori

    2014-11-01

    The purpose of this study was to clarify the biomechanical characteristics of cement-material interfaces for the zirconia ceramic and cobalt-chromium (Co-Cr) alloy femoral components used for total knee arthroplasty. In the first sub-study, we compared the strength of adhesion of the cement to flat plates, by tensile testing under dry and moistened conditions. In the second sub-study, we compared the maximum load of the cement-component complex by tensile testing. In the third sub-study, we compared the fatigue characteristics of the cement-component complex by use of a dynamic tensile testing machine. Under dry conditions, the maximum strength of adhesion to the zirconia ceramic plate was the same as that to the Co-Cr alloy plate. Under moistened conditions, however, the strength of adhesion to the zirconia ceramic plate was significantly lower (p = 0.0017) whereas the strength of adhesion to the Co-Cr alloy plate was not reduced. Maximum load for the cement-component complexes for zirconia ceramic and Co-Cr alloy was no different under both dry and moistened conditions. Fatigue testing showed that cement-zirconia adhesion was stronger than cement-Co-Cr alloy adhesion (p = 0.0161). The strength of adhesion of cement to zirconia ceramic is substantially weaker under wet conditions than under dry conditions. The mechanical properties of cement-zirconia ceramic component complexes and cement-Co-Cr alloy component complexes are equivalent.

  7. The effect of knee extensor open kinetic chain resistance training in the ACL-injured knee.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C; Milligan, Peter; Clinton, Melissa; Amis, Andrew A

    2015-11-01

    To investigate the effect of different loads of knee extensor open kinetic chain resistance training on anterior knee laxity and function in the ACL-injured (ACLI) knee. Fifty-eight ACLI subjects were randomised to one of three (12-week duration) training groups. The STAND group trained according to a standardised rehabilitation protocol. Subjects in the LOW and HIGH group trained as did the STAND group but with the addition of seated knee extensor open kinetic chain resistance training at loads of 2 sets of 20 repetition maximum (RM) and 20 sets of 2RM, respectively. Anterior knee laxity and measurements of physical and subjective function were performed at baseline, 6 and 12 weeks. Thirty-six subjects were tested at both baseline and 12 weeks (STAND n = 13, LOW n = 11, HIGH n = 12). The LOW group demonstrated a reduction in 133 N anterior knee laxity between baseline and 12 weeks testing when compared to the HIGH and the STAND groups (p = 0.009). Specifically, the trained-untrained knee laxity decreased an average of approximately 5 mm in the LOW group while remaining the same in the other two groups. Twelve weeks of knee extensor open kinetic chain resistance training at loads of 2 sets of 20RM led to a reduction in anterior knee laxity in the ACLI knee. This reduction in laxity does not appear to offer any significant short-term functional advantages when compared to a standard rehabilitation protocol. These results indicate that knee laxity can be decreased with resistance training of the thigh muscles. Randomised controlled trial, Level II.

  8. [Knee arthrodesis performed with intramedullary nailing technique in failed total knee replacement--a preliminary report].

    PubMed

    Gaździk, Tadeusz Szymon; Kotas-Strzoda, Justyna; Bozek, Marek

    2004-01-01

    Knee arthrodesis is the method of choice in treatment of failed total knee replacement. It is recommended when revisory total knee replacement is impossible. The authors present 2 cases of knee fusions using intramedullary nails after prosthesis loosening (1 aseptic, 1 septic). In both cases good results were achieved, with no complications observed during convalescence.

  9. Adaptation of NASA technology for the optimization of orthopedic knee implants

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Hopkins, D. A.

    1991-01-01

    The NASA technology originally developed for the optimization of composite structures (engine blades) is adapted and applied to the optimization of orthopedic knee implants. A method is developed enabling the tailoring of the implant for optimal interaction with the environment of the tibia. The shape of the implant components are optimized, such that the stresses in the bone are favorably controlled to minimize bone degradation and prevent failures. A pilot tailoring system is developed and the feasibility of the concept is elevated. The optimization system is expected to provide the means for improving knee prosthesis and individual implant tailoring for each patient.

  10. Effects of prophylactic knee bracing on knee joint kinetics and kinematics during netball specific movements.

    PubMed

    Sinclair, Jonathan K; Vincent, Hayley; Richards, Jim D

    2017-01-01

    To investigate the effects of a prophylactic knee brace on knee joint kinetics and kinematics during netball specific movements. Repeated measures. Laboratory. Twenty university first team level female netball players. Participants performed three movements, run, cut and vertical jump under two conditions (brace and no-brace). 3-D knee joint kinetics and kinematics were measured using an eight-camera motion analysis system. Knee joint kinetics and kinematics were examined using 2 × 3 repeated measures ANOVA whilst the subjective ratings of comfort and stability were investigated using chi-squared tests. The results showed no differences (p > 0.05) in knee joint kinetics. However the internal/external rotation range of motion was significantly (p < 0.05) reduced when wearing the brace in all movements. The subjective ratings of stability revealed that netballers felt that the knee brace improved knee stability in all movements. Further study is required to determine whether reductions in transverse plane knee range of motion serve to attenuate the risk from injury in netballers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    PubMed

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. EFFECTS OF THE GENIUM MICROPROCESSOR KNEE SYSTEM ON KNEE MOMENT SYMMETRY DURING HILL WALKING.

    PubMed

    Highsmith, M Jason; Klenow, Tyler D; Kahle, Jason T; Wernke, Matthew M; Carey, Stephanie L; Miro, Rebecca M; Lura, Derek J

    2016-09-01

    Use of the Genium microprocessor knee (MPK) system reportedly improves knee kinematics during walking and other functional tasks compared to other MPK systems. This improved kinematic pattern was observed when walking on different hill conditions and at different speeds. Given the improved kinematics associated with hill walking while using the Genium, a similar improvement in the symmetry of knee kinetics is also feasible. The purpose of this study was to determine if Genium MPK use would reduce the degree of asymmetry (DoA) of peak stance knee flexion moment compared to the C-Leg MPK in transfemoral amputation (TFA) patients. This study used a randomized experimental crossover of TFA patients using Genium and C-Leg MPKs ( n = 20). Biomechanical gait analysis by 3D motion tracking with floor mounted force plates of TFA patients ambulating at different speeds on 5° ramps was completed. Knee moment DoA was significantly different between MPK conditions in the slow and fast uphill as well as the slow and self-selected downhill conditions. In a sample of high-functioning TFA patients, Genium knee system accommodation and use improved knee moment symmetry in slow speed walking up and down a five degree ramp compared with C-Leg. Additionally, the Genium improved knee moment symmetry when walking downhill at comfortable speed. These results likely have application in other patients who could benefit from more consistent knee function, such as older patients and others who have slower walking speeds.

  13. Knee braces - unloading

    MedlinePlus

    ... most people talk about the arthritis in their knees, they are referring to a type of arthritis ... is caused by wear and tear inside your knee joints. Cartilage, the firm, rubbery tissue that cushions ...

  14. Knee arthroscopy - discharge

    MedlinePlus

    ... remove it. Torn or damaged anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL). Inflamed or damaged ... surgery Knee pain Meniscal allograft transplantation Patient Instructions ACL reconstruction - discharge Getting your home ready - knee or ...

  15. CKS knee prosthesis: biomechanics and clinical results in 42 cases.

    PubMed

    Martucci, E; Verni, E; Del Prete, G; Stulberg, S D

    1996-01-01

    From 1991 to 1993 a total of 42 CKS prostheses were implanted for the following reasons: osteoarthrosis (34 cases), rheumatoid arthritis (7 cases) tibial necrosis (1 case). At follow-up obtained after 17 to 41 months the results were: excellent or good: 41; the only poor result was probably related to excessive tension of the posterior cruciate ligament. 94% of the patients reported complete regression of pain, 85% was capable of going up and down stairs without support. Mean joint flexion was 105 degrees. Radiologically the anatomical axis of the knee had a mean valgus of anatomical axis of the knee had a mean valgus of 6 degrees. The prosthetic components were always cemented. The posterior cruciate ligament was removed in 7 knees, so that the prosthesis with "posterior stability" was used. The patella was never prosthetized. One patient complained of peri-patellar pain two months after surgery which then regressed completely.

  16. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  17. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Effectiveness of Knee Injury and Anterior Cruciate Ligament Tear Prevention Programs: A Meta-Analysis

    PubMed Central

    Collins, Jamie E.; Yang, Heidi Y.; Goczalk, Melissa G.; Katz, Jeffrey N.; Losina, Elena

    2015-01-01

    Objective Individuals frequently involved in jumping, pivoting or cutting are at increased risk of knee injury, including anterior cruciate ligament (ACL) tears. We sought to use meta-analytic techniques to establish whether neuromuscular and proprioceptive training is efficacious in preventing knee and ACL injury and to identify factors related to greater efficacy of such programs. Methods We performed a systematic literature search of studies published in English between 1996 and 2014. Intervention efficacy was ascertained from incidence rate ratios (IRRs) weighted by their precision (1/variance) using a random effects model. Separate analyses were performed for knee and ACL injury. We examined whether year of publication, study quality, or specific components of the intervention were associated with efficacy of the intervention in a meta-regression analysis. Results Twenty-four studies met the inclusion criteria and were used in the meta-analysis. The mean study sample was 1,093 subjects. Twenty studies reported data on knee injury in general terms and 16 on ACL injury. Maximum Jadad score was 3 (on a 0–5 scale). The summary incidence rate ratio was estimated at 0.731 (95% CI: 0.614, 0.871) for knee injury and 0.493 (95% CI: 0.285, 0.854) for ACL injury, indicating a protective effect of intervention. Meta-regression analysis did not identify specific intervention components associated with greater efficacy but established that later year of publication was associated with more conservative estimates of intervention efficacy. Conclusion The current meta-analysis provides evidence that neuromuscular and proprioceptive training reduces knee injury in general and ACL injury in particular. Later publication date was associated with higher quality studies and more conservative efficacy estimates. As study quality was generally low, these data suggest that higher quality studies should be implemented to confirm the preventive efficacy of such programs. PMID:26637173

  19. Cost-effectiveness of enhanced recovery in hip and knee replacement: a systematic review protocol

    PubMed Central

    Pritchard, Mark G; Cheng, Lok Yin; Janarthanan, Roshni

    2018-01-01

    Introduction Hip and knee replacement represents a significant burden to the UK healthcare system. ‘Enhanced recovery’ pathways have been introduced in the National Health Service (NHS) for patients undergoing hip and knee replacement, with the aim of improving outcomes and timely recovery after surgery. To support policymaking, there is a need to evaluate the cost-effectiveness of enhanced recovery pathways across jurisdictions. Our aim is to systematically summarise the published cost-effectiveness evidence on enhanced recovery in hip and knee replacement, both as a whole and for each of the various components of enhanced recovery pathways. Methods and analysis A systematic review will be conducted using MEDLINE, EMBASE, Econlit and the National Health Service Economic Evaluations Database. Separate search strategies were developed for each database including terms relating to hip and knee replacement/arthroplasty, economic evaluations, decision modelling and quality of life measures. We will extract peer-reviewed studies published between 2000 and 2017 reporting economic evaluations of preoperative, perioperative or postoperative enhanced recovery interventions within hip or knee replacement. Economic evaluations alongside cohort studies or based on decision models will be included. Only studies with patients undergoing elective replacement surgery of the hip or knee will be included. Data will be extracted using a predefined pro forma following best practice guidelines for economic evaluation, decision modelling and model validation. Our primary outcome will be the cost-effectiveness of enhanced recovery (entire pathway and individual components) in terms of incremental cost per quality-adjusted life year. A narrative synthesis of all studies will be presented, focussing on cost-effectiveness results, study design, quality and validation status. Ethics and dissemination This systematic review is exempted from ethics approval because the work is carried out

  20. Asymmetric ground reaction forces and knee kinematics during squat after anterior cruciate ligament (ACL) reconstruction.

    PubMed

    Sanford, Brooke A; Williams, John L; Zucker-Levin, Audrey; Mihalko, William M

    2016-10-01

    This bilateral squat study tests whether people with anterior cruciate ligament (ACL) reconstruction have symmetric three-dimensional ground reaction forces (GRFs) and symmetric anterior-posterior (AP) translation rates of the femur with respect to the tibia when compared with healthy control subjects. We hypothesized that there would be no long-term asymmetry in knee kinematics and kinetics in ACL reconstructed subjects following surgery and rehabilitation. Position and GRF data were collected on eight ACL reconstructed and eight control subjects during bilateral squat. The rate of relative AP translation was determined for each subject. Principal component models were developed for each of the three GRF waveforms. Principal component scores were used to assess symmetry within the ACL reconstructed group and within the control group. ACL reconstructed knees analyzed in early flexion during squat descent displayed a four-fold greater rate of change in anterior translation in the reconstructed knee relative to the contralateral side than did a similar comparison of normal knees. Differences were found between the ACL reconstructed subjects' injured and uninjured limbs for all GRFs. Subjects following ACL reconstruction had asymmetric GRFs and relative rates of AP translation at an average of seven years after ACL reconstructive surgery when compared with control subjects. These alterations in loading may lead to altered load distributions across the knee joint and may put some subjects at risk for future complications such as osteoarthritis. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis.

    PubMed

    Bhuiyan, M S H; Choudhury, I A; Dahari, M; Nukman, Y; Dawal, S Z

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e-004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb.

  2. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis

    PubMed Central

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e−004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb. PMID:28584518

  3. Special features of total knee replacement in hemophilia.

    PubMed

    Rodriguez-Merchan, Emerito Carlos

    2013-12-01

    Total knee replacement is an operation frequently needed by hemophilia patients, which greatly improves their quality of life. This operation, however, carries a higher risk of bleeding and infection for hemophiliacs than it does for osteoarthritis sufferers. It is advisable to implant prosthetic components using antibiotic-loaded cement. It is essential to maintain a level of 100% of the replacement clotting factor for 2 weeks. Hematological treatment must be established, depending on the patient's factor levels and other pharmacokinetic parameters such as recovery and half-life, optimal doses and treatment time. It is preferable to use general anesthesia due to the risk of spinal bleeding. The lifespan of total knee replacement in hemophilic patients is shorter than in patients with osteoarthritis because of the increased risk of infection.

  4. Microprocessor prosthetic knees.

    PubMed

    Berry, Dale

    2006-02-01

    This article traces the development of microprocessor prosthetic knees from early research in the 1970s to the present. Read about how microprocessor knees work, functional options, patient selection, and the future of this prosthetic.

  5. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    PubMed

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Dynamic Knee Alignment and Collateral Knee Laxity and Its Variations in Normal Humans

    PubMed Central

    Deep, Kamal; Picard, Frederic; Clarke, Jon V.

    2015-01-01

    Alignment of normal, arthritic, and replaced human knees is a much debated subject as is the collateral ligamentous laxity. Traditional quantitative values have been challenged. Methods used to measure these are also not without flaws. Authors review the recent literature and a novel method of measurement of these values has been included. This method includes use of computer navigation technique in clinic setting for assessment of the normal or affected knee before the surgery. Computer navigation has been known for achievement of alignment accuracy during knee surgery. Now its use in clinic setting has added to the inventory of measurement methods. Authors dispel the common myth of straight mechanical axis in normal knees and also look at quantification of amount of collateral knee laxity. Based on the scientific studies, it has been shown that the mean alignment is in varus in normal knees. It changes from lying non-weight-bearing position to standing weight-bearing position in both coronal and the sagittal planes. It also varies with gender and race. The collateral laxity is also different for males and females. Further studies are needed to define the ideal alignment and collateral laxity which the surgeon should aim for individual knees. PMID:26636090

  7. Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination.

    PubMed

    Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C

    2017-08-01

    The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.

  8. Correlations between iron content in knee joint tissues and chosen indices of peripheral blood morphology.

    PubMed

    Brodziak-Dopierała, Barbara; Roczniak, Wojciech; Jakóbik-Kolon, Agata; Kluczka, Joanna; Koczy, Bogdan; Kwapuliński, Jerzy; Babuśka-Roczniak, Magdalena

    2017-10-01

    Iron as a cofactor of enzymes takes part in the synthesis of the bone matrix. Severe deficiency of iron reduces the strength and mineral density of bones, whereas its excess may increase oxidative stress. In this context, it is essential to determine the iron content in knee joint tissues. The study objective was to determine the level of iron in the tissues of the knee joint, i.e., in the femoral bone, tibia and meniscus. Material for analysis was obtained during endoprosthetic surgery of the knee joint. Within the knee joint, the tibia, femur and meniscus were analyzed. Samples were collected from 50 patients, including 36 women and 14 men. The determination of iron content was performed with the ICP-AES method, using Varian 710-ES. The lowest iron content was in the tibia (27.04 μg/g), then in the meniscus (38.68 μg/g) and the highest in the femur (41.93 μg/g). Statistically significant differences were noted in the content of iron in knee joint tissues. In patients who underwent endoprosthesoplasty of the knee joint, statistically significant differences were found in the levels of iron in various components of the knee joint. The highest iron content was found in the femoral bone of the knee joint and then in the meniscus, the lowest in the tibia. The differences in iron content in the knee joint between women and men were not statistically significant.

  9. New Generation Lockable Knee Brace

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. Pictured here is a knee brace prototype being tested and fitted at Horton's Orthotic Lab. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  10. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury.

    PubMed

    Wellsandt, Elizabeth; Gardinier, Emily S; Manal, Kurt; Axe, Michael J; Buchanan, Thomas S; Snyder-Mackler, Lynn

    2016-01-01

    Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Case-control study; Level of evidence, 3. Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs -0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: -0.001 ± 0.032 N·m·s/kg·m [nonOA] vs -0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs -0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak medial compartment contact forces of the involved limb

  11. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury

    PubMed Central

    Wellsandt, Elizabeth; Gardinier, Emily S.; Manal, Kurt; Axe, Michael J.; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Hypothesis Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Study Design Case-control study; Level of evidence, 3. Methods Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Results Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs −0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: −0.001 ± 0.032 N·m·s/kg·m [nonOA] vs −0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs −0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak

  12. The role of knee alignment in disease progression and functional decline in knee osteoarthritis.

    PubMed

    Sharma, L; Song, J; Felson, D T; Cahue, S; Shamiyeh, E; Dunlop, D D

    2001-07-11

    Knee osteoarthritis (OA) is a leading cause of disability in older persons. Few risk factors for disease progression or functional decline have been identified. Hip-knee-ankle alignment influences load distribution at the knee; varus and valgus alignment increase medial and lateral load, respectively. To test the hypotheses that (1) varus alignment increases risk of medial knee OA progression during the subsequent 18 months, (2) valgus alignment increases risk of subsequent lateral knee OA progression, (3) greater severity of malalignment is associated with greater subsequent loss of joint space, and (4) greater burden of malalignment is associated with greater subsequent decline in physical function. Prospective longitudinal cohort study conducted March 1997 to March 2000 at an academic medical center in Chicago, Ill. A total of 237 persons recruited from the community with primary knee OA, defined by presence of definite tibiofemoral osteophytes and at least some difficulty with knee-requiring activity; 230 (97%) completed the study. Progression of OA, defined as a 1-grade increase in severity of joint space narrowing on semiflexed, fluoroscopically confirmed knee radiographs; change in narrowest joint space width; and change in physical function between baseline and 18 months, compared by knee alignment at baseline. Varus alignment at baseline was associated with a 4-fold increase in the odds of medial progression, adjusting for age, sex, and body mass index (adjusted odds ratio [OR], 4.09; 95% confidence interval [CI], 2.20-7.62). Valgus alignment at baseline was associated with a nearly 5-fold increase in the odds of lateral progression (adjusted OR, 4.89; 95% CI, 2.13-11.20). Severity of varus correlated with greater medial joint space loss during the subsequent 18 months (R = 0.52; 95% CI, 0.40-0.62 in dominant knees), and severity of valgus correlated with greater subsequent lateral joint space loss (R = 0.35; 95% CI, 0.21-0.47 in dominant knees). Having

  13. Location of the Common Peroneal Nerve in Valgus Knees-Is the Reported Safe Zone for Well-Aligned Knees Applicable?

    PubMed

    Yang, Dejin; Shao, Hongyi; Zhou, Yixin; Tang, Hao; Guo, Shengjie

    2017-11-01

    Lateral soft-tissue release can jeopardize the common peroneal nerve (CPN) in total knee arthroplasty for valgus knees. Previous studies reporting safe zones to protect the CPN were based on well-aligned knees. We conducted this study to compare the localization of the CPN in well-aligned knees and in valgus knees. We conducted a consecutive 3-dimensional radiographic study on magnetic resonance images of 58 well-aligned knees and 39 valgus knees. We measured the distance between the CPN and the tibia, as well as the mediolateral, anteroposterior, and angular location of the CPN. We compared the results between well-aligned knees and valgus knees. We found that there is an increased distance between the CPN and the tibia at the level of the tibial cut, but not at the joint line in valgus knees. It is safer to release the posterolateral capsule at the tibial side than at the level above this. The angular location and the mediolateral or anteroposterior location of the CPN in valgus knees are similar to those of well-aligned knees. The location of the CPN in valgus knees is similar to that in well-aligned knees. The previously reported safe zone in well-aligned knees is applicable in valgus knees to protect the CPN. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Intramedullary knee arthrodesis as a salvage procedure after failed total knee replacement.

    PubMed

    Panagiotopoulos, E; Kouzelis, A; Matzaroglou, Ch; Saridis, A; Lambiris, E

    2006-12-01

    Septic and aseptic loosening with or without extensive bone loss after total knee replacement are the most common indications for knee fusion. Both external fixation and intramedullary nailing can be used for the treatment, though the latter appears to be the method of choice for most patients. Nine patients were treated after a total knee replacement failure using intramedullary nailing. A long intramedullary nail with a proximal interlocking screw was used in five cases, and a customised nail was used in four cases. Successful fusion occurred in eight of nine patients (89%). Average time for the joint union was 6.5 months, and average operative blood loss was 860 ml. In two patients, iliac crest and patellar bone graft were also used. In conclusion, intramedullary nailing can give excellent results in achieving knee fusion after a failed knee replacement as it allows early weight bearing and at the same time offers stability, pain relief, and a high rate of union, even though the surgical technique is demanding.

  15. Cartilage Thickening in Early Radiographic Human Knee Osteoarthritis –Within-Person, Between-Knee Comparison

    PubMed Central

    Cotofana, Sebastian; Buck, Robert; Wirth, Wolfgang; Roemer, Frank; Duryea, Jeff; Nevitt, Michael; Eckstein, Felix

    2012-01-01

    Objective To determine whether the presence of definite osteophytes (in absence of joint space narrowing [JSN]) by radiograph is associated with (subregional) increases in cartilage thickness, in a within-person, between-knee cross-sectional comparison of participants in the Osteoarthritis Initiative (OAI). Based on previous results, external medial (ecMF) and external lateral weight-bearing femoral (ecLF) subregions were selected as primary endpoints. Methods Both knees of 61 (of 4798) OAI participants displayed definite tibial or femoral marginal osteophytes and no JSN in one knee, and no signs of radiographic OA in the contra-lateral knee; this being confirmed by an expert central reader. In these participants, cartilage thickness was measured in 16 femorotibial subregions of each knee, based on sagittal DESSwe magnetic resonance images. Location-specific joint space width from fixed flexion radiographs was determined using dedicated software. Location-specific associations of osteophytes with cartilage thickness were evaluated using paired t-tests and mixed effect models. Results Of the 61 participants, 48% had only medial, 36% only lateral, and 16% bi-compartmental osteophytes. Osteophyte knees had significantly thicker cartilage than contra-lateral non-osteophyte knees in the ecMF (+71±223μm, equivalent to +5.5%, p=0.015) and ecLF (+64±195μm, +4.1%, p=0.013). No significant differences between knees were noted in other subregions, nor in joint space width. Cartilage thickness in ecMF and ecLF was significantly associated with tibial osteophytes in the same (medial or lateral) compartment (p=0.003). Conclusion Knees with early radiographic OA display thicker cartilage than (contra-lateral) knees without radiographic findings of OA, specifically in the external femoral subregions of compartments with marginal osteophytes. PMID:22556039

  16. Knee Extensor Strength and Gait Characteristics After Minimally Invasive Unicondylar Knee Arthroplasty vs Minimally Invasive Total Knee Arthroplasty: A Nonrandomized Controlled Trial.

    PubMed

    Braito, Matthias; Giesinger, Johannes M; Fischler, Stefan; Koller, Arnold; Niederseer, David; Liebensteiner, Michael C

    2016-08-01

    In light of the existing lack of evidence, it was the aim of this study to compare gait characteristics and knee extensor strength after medial unicondylar knee arthroplasty (MUKA) with those after total knee arthroplasty (TKA), given the same standardized minimally invasive surgery (MIS) approach in both groups. Patients scheduled for MIS-MUKA or MIS-TKA as part of clinical routine were invited to participate. A posterior cruciate ligament-retaining total knee design was used for all MIS-TKA. A 3-dimensional gait analysis was performed preoperatively with a VICON system and at 8 weeks postoperative to determine temporospatial parameters, ground reaction forces, joint angles, and joint moments. At the same 2 times, isokinetic tests were performed to obtain peak values of knee extensor torque. A multivariate analysis of variance was conducted and included the main effects time (before and after surgery) and surgical group and the group-by-time interaction effect. Fifteen MIS-MUKA patients and 17 MIS-TKA patients were eligible for the final analysis. The groups showed no differences regarding age, body mass index, sex, side treated, or stage of osteoarthritis. We determined neither intergroup differences nor time × group interactions for peak knee extensor torque or any gait parameters (temporospatial, ground reaction forces, joint angles, and joint moments). It is concluded that MUKA is not superior to TKA with regard to knee extensor strength or 3-dimensional gait characteristics at 8 weeks after operation. As gait characteristics and knee extensor strength are only 2 of the various potential outcome parameters (knee scores, activity scores…) and quadriceps strength might take a longer time to recover, our findings should be interpreted with caution. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Raman spectroscopy of dried synovial fluid droplets as a rapid diagnostic for knee joint damage

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Raaii, Farhang; Roessler, Blake J.; Morris, Michael D.

    2008-02-01

    Human synovial fluid droplets were investigated using drop deposition in combination with Raman spectroscopy. Following informed consent, synovial fluid was obtained from forty human patients with various severities of knee pain and/or osteoarthritis at the time of knee arthroscopy or total joint replacement. Synovial fluid was aspirated from the knee joint of each patient and stored at -80°C until examination by near-infrared Raman spectroscopy. Synovial fluid aspirates from the knee joint of each patient were deposited onto a clean fused silica microscope slide and the droplet dried under ambient laboratory conditions. Each droplet was illuminated by a line-focused or a ring-focused 785 nm laser. As the droplet dries, biofluid components segregated based on solubility differences and a deposit that is spatially heterogeneous was made. Spectra taken from the droplet edges and center were dominated by protein bands and showed the presence of at least two protein moieties in the droplet. Band area and band height ratios (1410 cm -1/1450 cm -1) showed the greatest change between specimens from patients with mild/early osteoarthritis compared to those with severe/late stage osteoarthritis. The greatest differences were found in the center of the droplet, which contains more soluble protein components than the edges.

  18. [Mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity].

    PubMed

    Zeng, Min; Hu, Yihe; Xie, Jie; Li, Mingqing; Lin, Shaoru

    2014-01-01

    To evaluate the mid-term effectiveness of rotating hinge knee prosthesis for severe knee deformity. A retrospective analysis was made on the clinical data of 24 patients (24 knees) who received rotating hinge knee prosthesis for total knee arthroplasty between January 2003 and June 2011. There were 14 males and 10 females, aged from 60 to 81 years (mean, 70 years). The disease causes included osteoarthritis in 5 cases, rheumatoid arthritis in 7 cases, traumatic arthritis in 9 cases, and Charcot's arthropathy in 3 cases. The disease duration ranged from 5 to 25 years (mean, 14.5 years). Of them, 13 cases had flexion deformity, 7 cases had valgus deformity, and 16 cases had varus deformity. The operation time, the amount of bleeding between operation and drainage-tubes removal, hospitalization time, incision healing, and complications were recorded. The results were evaluated according to Knee Society Score (KSS), visual analogue scale (VAS), and the range of motion (ROM) of knee. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. The position of prosthesis was observed through X-ray examination. The operation time ranged from 70 to 90 minutes (mean, 78 minutes). The amount of bleeding between operation and drainage-tubes removal ranged from 400 to 1 000 mL (mean, 650 mL). The hospitalization time ranged from 14 to 18 days (mean, 15.2 days). Patellar fracture occurred in 1 case (4.17%) during operation, swelling and effusion of incision in 1 case (4.17%), and periprosthetic infections in 2 cases (8.33%) after operation. All patients were followed up 2-10 years (mean, 5.5 years). The X-ray films showed no evidence of obvious radiolucent line, osteolysis, prosthesis subsidence, and limb alignment change. The results of KSS, VAS socres, and ROM of knee at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P < 0.05), but no significant difference was found between at 1 year postoperatively

  19. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    PubMed

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A comparison of registration errors with imageless computer navigation during MIS total knee arthroplasty versus standard incision total knee arthroplasty: a cadaveric study.

    PubMed

    Davis, Edward T; Pagkalos, Joseph; Gallie, Price A M; Macgroarty, Kelly; Waddell, James P; Schemitsch, Emil H

    2015-01-01

    Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manual registration of landmarks. Our study aims to compare the registration process error between a standard and a MIS surgical approach. We hypothesized that performing the registration error via an MIS approach would increase the registration process error. Five fresh frozen lower limbs were routinely prepared and draped. The registration process was performed through an MIS approach. This was then extended to the standard approach and the registration was performed again. Two surgeons performed the registration process five times with each approach. Performing the registration process through the MIS approach was not associated with higher error compared to the standard approach in the alignment parameters of interest. This rejects our hypothesis. Image-free navigated MIS TKR does not appear to carry higher risk of component malalignment due to the registration process error. Navigation can be used during MIS TKR to improve alignment without reduced accuracy due to the approach.

  1. The John Insall Award: Both morphotype and gender influence the shape of the knee in patients undergoing TKA.

    PubMed

    Bellemans, Johan; Carpentier, Karel; Vandenneucker, Hilde; Vanlauwe, Johan; Victor, Jan

    2010-01-01

    There is an ongoing debate whether gender differences in the dimensions of the knee should influence the design of TKA components. We hypothesized that not only gender but also the patient's morphotype determined the shape of the distal femur and proximal tibia and that this factor should be taken into account when designing gender-specific TKA implants. We reviewed all 1000 European white patients undergoing TKA between April 2003 and June 2007 and stratified each into one of three groups based on their anatomic constitution: endomorph, ectomorph, or mesomorph. Of the 250 smallest knees, 98% were female, whereas 81% of the 250 largest knees were male. In the group with intermediate-sized knees, female knees were narrower than male knees. Patients with smaller knees (predominantly female) demonstrated large variability between narrow and wide mediolateral dimensions irrespective of gender. The same was true for larger knees (predominantly male). This variability within gender could partially be explained by morphotypic variation. Patients with short and wide morphotype (endomorph) had, irrespective of gender, wider knees, whereas patients with long and narrow morphotype (ectomorph) had narrower knees. The shape of the knee is therefore not only dependent on gender, but also on the morphotype of the patient. Level I, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  2. Longitudinal changes in knee kinematics and moments following knee arthroplasty: a systematic review.

    PubMed

    Sosdian, L; Dobson, F; Wrigley, T V; Paterson, K; Bennell, K; Dowsey, M; Choong, P; Allison, K; Hinman, R S

    2014-12-01

    Knee arthroplasty (KA) is recognized as an effective treatment of knee joint osteoarthritis and up to 90% of patients experience substantial pain relief. There has been no systematic review synthesizing the longitudinal changes in gait following KA. The aims of this systematic review were to determine the effects of KA on (i) frontal plane and (ii) sagittal plane kinematic and kinetic parameters during the stance phase of gait. MEDLINE (PubMed), CINAHL, SPORTdiscus (EBSCO), and Cochrane Library (Wiley) were searched until April 10th, 2014. 1,765 articles were identified, of which 19 studies describing 3-dimensional gait analysis pre- and post-KA were included. Study quality was evaluated by two reviewers independently using the Downs and Black checklist. Following KA, in the frontal plane, the maximum knee adduction angle and external knee adduction moment (KAM) tended to decrease. In the sagittal plane, findings suggest that the maximum knee flexion moment is increased. From the ten studies that included a healthy reference group, it was unclear whether gait variables returned to normal following KA. Overall, it appears that KA results in a decreased peak KAM and maximum knee adduction angles, an increased peak knee flexion moment and inconsistent changes in the peak knee flexion angle. Knowledge gaps remain due to methodological inconsistencies across studies, limited statistical analysis, and largely heterogeneous sample populations. More research is needed to determine whether KA restores gait patterns to normal, or if additional rehabilitation may be needed to optimize gait following surgery for osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. The role of the posterior cruciate ligament in total knee replacement

    PubMed Central

    Ritter, M. A.; Davis, K. E.; Meding, J. B.; Farris, A.

    2012-01-01

    Objectives The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement. Methods A total of 3018 anatomic graduated component total knee replacements were examined; 1846 of these retained the PCL, 455 PCLs were partially recessed, and in 717 the PCL was completely excised from the back of the tibia. Results Clinical scores between PCL groups favored excision for flexion (p < 0.0001), and recession and retention for stairs (p < 0.0001). There was a mild difference in long-term all-cause aseptic survivorship between PCL-retained (96.4% at 15 years) combined with PCL-recessed groups (96.6% at 15 years) when compared with the PCL-excised group (95.0% at 15 years) (p = 0.0411, Wilcoxon; p = 0.0042, log-rank), as well as tibial or femoral loosening, which reported prosthesis survival of 97.8% at 15 years for PCL-retained knees, 98.2% for recessed knees, and 96.4% for excised knees (p = 0.0934, Wilcoxon; p = 0.0202, log-rank). Conclusions Despite some trade off in clinical performance, if the PCL is detached at the time of operation, conversion to a posterior-stabilised prosthesis may not be necessarily required as long as stability in the anteroposterior and coronal planes is achieved. PMID:23610673

  4. Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

    PubMed

    Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J

    2013-06-01

    Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.

  5. Knee extensor strength and body weight in adolescent men and the risk of knee osteoarthritis by middle age.

    PubMed

    Turkiewicz, Aleksandra; Timpka, Simon; Thorlund, Jonas Bloch; Ageberg, Eva; Englund, Martin

    2017-10-01

    To assess the extent to which knee extensor strength and weight in adolescence are associated with knee osteoarthritis (OA) by middle age. We studied a cohort of 40 121 men who at age 18 years in 1969/1970 underwent mandatory conscription in Sweden. We retrieved data on isometric knee extensor strength, weight, height, smoking, alcohol consumption, parental education and adult occupation from Swedish registries. We identified participants diagnosed with knee OA or knee injury from 1987 to 2010 through the National Patient Register. We estimated the HR of knee OA using multivariable-adjusted Cox proportional regression model. To assess the influence of adult knee injury and occupation, we performed a formal mediation analysis. The mean (SD) knee extensor strength was 234 (47) Nm, the mean (SD) weight was 66 (9.3) kg. During 24 years (median) of follow-up starting at the age of 35 years, 2049 persons were diagnosed with knee OA. The adjusted HR (95% CI) of incident knee OA was 1.12 (1.06 to 1.18) for each SD of knee extensor strength and 1.18 (1.15 to 1.21) per 5 kg of body weight. Fifteen per cent of the increase in OA risk due to higher knee extensor strength could be attributed to knee injury and adult occupation. Higher knee extensor strength in adolescent men was associated with increased risk of knee OA by middle age, challenging the current tenet of low muscle strength being a risk factor for OA. We confirmed higher weight to be a strong risk factor for knee OA. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Joskowicz, Leo; Pearle, Andrew D

    2016-11-01

    Recently, there is a growing interest in surgical variables that are intraoperatively controlled by orthopaedic surgeons, including lower leg alignment, component positioning and soft tissues balancing. Since more tight control over these factors is associated with improved outcomes of unicompartmental knee arthroplasty and total knee arthroplasty (TKA), several computer navigation and robotic-assisted systems have been developed. Although mechanical axis accuracy and component positioning have been shown to improve with computer navigation, no superiority in functional outcomes has yet been shown. This could be explained by the fact that many differences exist between the number and type of surgical variables these systems control. Most systems control lower leg alignment and component positioning, while some in addition control soft tissue balancing. Finally, robotic-assisted systems have the additional advantage of improving surgical precision. A systematic search in PubMed, Embase and Cochrane Library resulted in 40 comparative studies and three registries on computer navigation reporting outcomes of 474,197 patients, and 21 basic science and clinical studies on robotic-assisted knee arthroplasty. Twenty-eight of these comparative computer navigation studies reported Knee Society Total scores in 3504 patients. Stratifying by type of surgical variables, no significant differences were noted in outcomes between surgery with computer-navigated TKA controlling for alignment and component positioning versus conventional TKA (p = 0.63). However, significantly better outcomes were noted following computer-navigated TKA that also controlled for soft tissue balancing versus conventional TKA (mean difference 4.84, 95 % Confidence Interval 1.61, 8.07, p = 0.003). A literature review of robotic systems showed that these systems can, similarly to computer navigation, reliably improve lower leg alignment, component positioning and soft tissues balancing. Furthermore

  7. Age and Preoperative Knee Society Score Are Significant Predictors of Outcomes Among Asians Following Total Knee Arthroplasty.

    PubMed

    Bin Abd Razak, Hamid Rahmatullah; Tan, Chuen-Seng; Chen, Yongqiang Jerry Delphi; Pang, Hee-Nee; Tay, Keng-Jin Darren; Chin, Pak-Lin; Chia, Shi-Lu; Lo, Ngai-Nung; Yeo, Seng-Jin

    2016-05-04

    The ability to predict patients' functional outcomes will add value to preoperative counseling. The purpose of this study was to evaluate predictors of good outcomes following total knee arthroplasty (TKA) among Asian patients. Registry data from 2006 to 2010 were extracted. The Oxford Knee Score (OKS) and the Short Form (SF)-36 physical component summary (PCS) were used to evaluate outcomes. A "good outcome" was defined as an improvement in scores of greater than or equal to the minimal clinically important difference (MCID) in the primary analysis. The MCID for the OKS was 5, and the MCID for the PCS was 10. For the sensitivity analyses, a "good outcome" was defined as an OKS of <30 and a PCS score of >50. Clinical variables were used to develop a multiple logistic regression model for a good outcome following total knee arthroplasty at 5 years. Follow-up data were available for 3,062 patients who underwent primary TKA (mean age of 66.4 years; 79.5% female). Eighty-five percent had a good outcome on the basis of the OKS and 83%, on the basis of the SF-36 PCS. Age and preoperative Knee Society score (KSS) were found to be significant predictors. When outcomes were assessed by the MCID, lesser age and lower (worse) preoperative KSS predicted a good outcome at 5 years. When outcomes were assessed by absolute criteria (postoperative scores measured against OKS and PCS thresholds), a higher (better) preoperative KSS predicted a good outcome at 5 years. Body mass index, preoperative flexion range, SF-36 mental component summary (MCS) score, mechanical alignment, sex, education level, ethnicity, operative side, number of comorbidities, type of anesthesia, and type of implant were found not to be significant predictors. The majority of Asian patients with osteoarthritis had good outcomes according to the MCID criterion and benefitted from primary TKA. On the basis of our findings, we believe that older patients with a lower (worse) preoperative KSS can be informed that

  8. Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial.

    PubMed

    Chen, Jerry Yongqiang; Chin, Pak Lin; Li, Zongxian; Yew, Andy Khye Soon; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin

    2015-12-01

    This study aimed to investigate the accuracy of pinless navigation (BrainLAB(®) VectorVision(®) Knee 2.5 Navigation System) as an intra-operative alignment guide in total knee arthroplasty (TKA). The authors hypothesized that pinless navigation would reduce the proportion of outliers in conventional TKA, without a significant increase in the duration of surgery. Between 2011 and 2012, 100 patients scheduled for a unilateral primary TKA were randomized into two groups: pinless navigation and conventional surgery. All TKAs were performed with the surgical aim of achieving neutral coronal alignment with a 180° mechanical axis. The primary outcomes of this study were post-operative radiographic assessment of lower limb alignment using hip-knee-ankle angle (HKA) and components placement using coronal femoral-component angle (CFA) and coronal tibia-component angle (CTA). There was a smaller proportion of outliers for HKA, CFA and CTA at 10, 2 and 2 % respectively, in the pinless navigation group, compared to 32, 16 and 16 %, respectively, in the conventional group (p = 0.013, p = 0.032 and p = 0.032, respectively). The mean CFA was also more accurate at 90° in the pinless navigation group compared to 91° in the conventional group (p = 0.002). There was no difference in the duration of surgery between the two groups (n.s.). Pinless navigation improves lower limb alignment and components placement without a significant increase in the duration of surgery. The authors recommend the use of pinless navigation to verify the coronal alignments of conventional cutting blocks in TKA before the bone cuts are made. I.

  9. Lateral thrust of anterior cruciate ligament-insufficient knees and posterior cruciate ligament-insufficient knees.

    PubMed

    Yoshimura, Ichiro; Naito, Masatoshi; Zhang, Jingfan

    2002-01-01

    Leaving anterior cruciate ligament (ACL) insufficiency and posterior cruciate ligament (PCL) insufficiency untreated frequently leads to osteoarthritis (OA). The purpose of this study was to evaluate dynamically the lateral thrust of ACL-insufficient knees and PCL-insufficient knees, and from the findings investigate the relationship between cruciate ligament insufficiency and OA occurrence. An acceleration sensor was attached to the affected and control anterior tibial tubercles, acting in medial-lateral and perpendicular directions. The lateral thrust immediately after heel strike was measured continuously by a telemeter under stabilised walking conditions. When compared to the contralateral healthy knee, the peak value of lateral acceleration immediately after heel strike was significantly larger in the ACL-insufficient knee; and lateral thrust was increased, but not significantly, in the PCL-insufficient knee. Given that lateral thrust of the knee during walking increases due to ACL or PCL injury, it may be a principal contributor to OA progression.

  10. Lateral trunk lean and medializing the knee as gait strategies for knee osteoarthritis.

    PubMed

    Gerbrands, T A; Pisters, M F; Theeven, P J R; Verschueren, S; Vanwanseele, B

    2017-01-01

    To determine (1) if Medial Thrust or Trunk Lean reduces the knee adduction moment (EKAM) the most during gait in patients with medial knee osteoarthritis, (2) if the best overall strategy is the most effective for each patient and (3) if these strategies affect ankle and hip kinetics. Thirty patients with symptomatic medial knee osteoarthritis underwent 3-dimensional gait analysis. Participants received verbal instructions on two gait strategies (Trunk Lean and Medial Thrust) in randomized order after comfortable walking was recorded. The peaks and impulse of the EKAM and strategy-specific kinematic and kinetic variables were calculated for all conditions. Early stance EKAM peak was significantly reduced during Medial Thrust (-29%). During Trunk Lean, early and late stance EKAM peak and EKAM impulse reduced significantly (38%, 21% and -25%, respectively). In 79% of the subjects, the Trunk Lean condition was significantly more effective in reducing EKAM peak than Medial Thrust. Peak ankle dorsi and plantar flexion, knee flexion and hip extension and adduction moments were not significantly increased. Medial Thrust and Trunk Lean reduced the EKAM during gait in patients with knee osteoarthritis. Individual selection of the most effective gait modification strategy seems vital to optimally reduce dynamic knee loading during gait. No detrimental effects on external ankle and hip moments or knee flexion moments were found for these conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Characterizing the recovery trajectories of knee range of motion for one year after total knee replacement.

    PubMed

    Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali

    2018-06-13

    Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.

  12. New Generation Lockable Knee Brace

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  13. Nontraumatic Fracture of the Femoral Condylar Prosthesis in a Total Knee Arthroplasty Leading to Mechanical Failure

    PubMed Central

    Swamy, Girish N.; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P.

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before. PMID:24587928

  14. Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure.

    PubMed

    Swamy, Girish N; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  15. High-grade rotatory knee laxity may be predictable in ACL injuries.

    PubMed

    Musahl, Volker; Burnham, Jeremy; Lian, Jayson; Popchak, Adam; Svantesson, Eleonor; Kuroda, Ryosuke; Zaffagnini, Stefano; Samuelsson, Kristian

    2018-06-21

    and translation are elevated. Surgeons should have a greater degree of suspicion for high-grade rotatory knee laxity in ACL-injured males with concomitant lateral meniscus tears. Future studies should investigate how these two distinct components of rotatory knee laxity-lateral compartment acceleration and translation-are correlated with patient outcomes and affected by ACL surgery. Prospective cohort study; Level of evidence II.

  16. In Vivo Wear Performance of Cobalt-Chromium Versus Oxidized Zirconium Femoral Total Knee Replacements.

    PubMed

    Gascoyne, Trevor C; Teeter, Matthew G; Guenther, Leah E; Burnell, Colin D; Bohm, Eric R; Naudie, Douglas R

    2016-01-01

    This study examines the damage and wear on the polyethylene (PE) inserts from 52 retrieved Genesis II total knee replacements to identify differences in tribological performance between matched pairs of cobalt-chromium (CoCr) and oxidized zirconium (OxZr) femoral components. Observer damage scoring and microcomputed tomography were used to quantify PE damage and wear, respectively. No significant differences were found between CoCr and OxZr groups in terms of PE insert damage, surface penetration, or wear. No severe damage such as cracking or delamination was noted on any of the 52 PE inserts. Observer damage scoring did not correlate with penetrative or volumetric PE wear. The more costly OxZr femoral component does not demonstrate clear tribological benefit over the standard CoCr component in the short term with this total knee replacement design. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Individual MRI and radiographic features of knee OA in subjects with unilateral knee pain: Health ABC study

    PubMed Central

    Javaid, MK; Kiran, A; Guermazi, A; Kwoh, K; Zaim, S; Carbone, L; Harris, T.; McCulloch, C.E.; Arden, NK; Lane, NE; Felson, D; Nevitt, M

    2012-01-01

    Strong associations between radiographic features of knee OA and pain have been demonstrated in persons with unilateral knee symptoms. Our objectives were to compare radiographic with MRI features of knee OA and assess the discrimination between painful and non-painful knees in persons with unilateral symptoms. 283 individuals with unilateral knee pain aged 71 to 80 years from Health ABC, a study of weight-related diseases and mobility, had bilateral knee radiographs, read for KL grade and individual radiographic features, and 1.5T MRIs, read using WORMS. The association of structural features with pain was assessed using a within-person case/control design and conditional logistic regression. Receiver operator characteristics (ROC) were then used to test the discriminatory performance of structural features. In conditional logistic analyses, knee pain was significantly associated with both radiographic (any JSN grade >=1: OR 3.20 (1.79 – 5.71) and MRI (any cartilage defect:>=2: OR 3.67 (1.49 – 9.04)) features. However, most subjects had MR detected osteophytes, cartilage and bone marrow lesions in both knees and no individual structural feature discriminated well between painful and non-painful knees using ROC. The best performing MRI feature (synovitis/effusion) was not significantly more informative than KL grade >=2 (p=0.42). In persons with unilateral knee pain, MR and radiographic features were associated with knee pain confirming an important role in the etiology of pain. However, no single MRI or radiographic finding performed well in discriminating painful from non-painful knees. Further work is needed to examine how structural and non-structural factors influence knee pain. PMID:22736267

  18. The anteroposterior axis of the tibia in Korean patients undergoing total knee replacement.

    PubMed

    Kim, C W; Seo, S S; Kim, J H; Roh, S M; Lee, C R

    2014-11-01

    The aim of this study was to find anatomical landmarks for rotational alignment of the tibial component in total knee replacement (TKR) in a CT-based study. Pre-operative CT scanning was performed on 94 South Korean patients (nine men, 85 women, 188 knees) with osteoarthritis of the knee joint prior to TKR. The tibial anteroposterior (AP) axis was defined as a line perpendicular to the femoral surgical transepicondylar axis and passing through the centre of the posterior cruciate ligament (PCL). The angles between the defined tibial AP axis and anatomical landmarks at various levels of the tibia were measured. The mean values of the angles between the defined tibial AP axis and the line connecting the anterior border of the proximal third of the tibia to the centre of the PCL was -0.2° (-17 to 14.1, sd 4.1). This was very close to the defined tibial axis, and remained so regardless of lower limb alignment and the degree of tibial bowing. Therefore, AP axis defined as described, is a reliable anatomical landmark for rotational alignment of tibial components. ©2014 The British Editorial Society of Bone & Joint Surgery.

  19. Varus thrust in women with early medial knee osteoarthritis and its relation with the external knee adduction moment.

    PubMed

    Mahmoudian, Armaghan; van Dieen, Jaap H; Bruijn, Sjoerd M; Baert, Isabel Ac; Faber, Gert S; Luyten, Frank P; Verschueren, Sabine Mp

    2016-11-01

    Varus thrust, defined as an abrupt increase of the knee varus angle during weight-bearing in gait, has been shown to be present in patients with moderate to severe knee osteoarthritis and is considered to be one of the risk factors for progression of symptomatic medial knee osteoarthritis. We evaluated the presence and magnitude of varus thrust and its relation with the Knee Adduction Moment in women with early medial knee osteoarthritis, and compared it to that in a group of controls and in a group of subjects with established medial knee osteoarthritis. Twenty-seven women with early medial knee osteoarthritis, 20 women with established medial knee osteoarthritis and 24 asymptomatic controls were evaluated. Varus thrust was estimated as an increase of the knee varus angle during the weight-bearing phase of gait at self-selected speed, assessed by 3D motion analysis. Varus thrust was significantly higher in both early and established osteoarthritis groups compared to the control group (P<0.001), but not different between osteoarthritis groups. While the knee adduction moments were higher than controls only in the established osteoarthritis group, the magnitude of varus thrust was significantly correlated with the second peak knee adduction moment. Higher varus thrust was found both in early and established stages of knee osteoarthritis, suggesting that problems with dynamic stabilization of the knee are present early in the development of knee osteoarthritis. This highlights the necessity of considering dynamic alignment in rehabilitation already in the early stages of the disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. The importance of bony impingement in restricting flexion after total knee arthroplasty: computer simulation model with clinical correlation.

    PubMed

    Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D

    2012-10-01

    We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with <100° of flexion and high-flex group: 15 size-matched knees with >125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Knee Brace Would Lock And Unlock Automatically

    NASA Technical Reports Server (NTRS)

    Myers, Neill; Forbes, John; Shadoan, Mike; Baker, Kevin

    1995-01-01

    Proposed knee brace designed to aid rehabilitation of person who suffered some muscle damage in leg. Not limited to locking in straight-leg position and, instead, locks at any bend angle. Does not prevent knee from bearing weight. Instead, knee brace allows knee to bear weight and locks only when foot and lower leg bear weight. Thus, brace prevents flexion that wearer desired to prevent but could not prevent because of weakened muscles. Knee bends freely to exercise knee-related muscles. Knee brace strapped at upper end to leg above knee, and anchored at lower end by stirrup under foot. Joint mechanism (identical mechanisms used in left and right assemblies) allows knee joint to flex freely except when weight applied to heel.

  2. [Surgical technique and clinical results of total knee arthroplasty in treating endstage gonarthrosis combined with valgus knee deformity].

    PubMed

    Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei

    2012-05-01

    To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6

  3. Pain sensitivity profiles in patients with advanced knee osteoarthritis

    PubMed Central

    Frey-Law, Laura A.; Bohr, Nicole L.; Sluka, Kathleen A.; Herr, Keela; Clark, Charles R.; Noiseux, Nicolas O.; Callaghan, John J; Zimmerman, M Bridget; Rakel, Barbara A.

    2016-01-01

    The development of patient profiles to subgroup individuals on a variety of variables has gained attention as a potential means to better inform clinical decision-making. Patterns of pain sensitivity response specific to quantitative sensory testing (QST) modality have been demonstrated in healthy subjects. It has not been determined if these patterns persist in a knee osteoarthritis population. In a sample of 218 participants, 19 QST measures along with pain, psychological factors, self-reported function, and quality of life were assessed prior to total knee arthroplasty. Component analysis was used to identify commonalities across the 19 QST assessments to produce standardized pain sensitivity factors. Cluster analysis then grouped individuals that exhibited similar patterns of standardized pain sensitivity component scores. The QST resulted in four pain sensitivity components: heat, punctate, temporal summation, and pressure. Cluster analysis resulted in five pain sensitivity profiles: a “low pressure pain” group, an “average pain” group, and three “high pain” sensitivity groups who were sensitive to different modalities (punctate, heat, and temporal summation). Pain and function differed between pain sensitivity profiles, along with sex distribution; however no differences in OA grade, medication use, or psychological traits were found. Residualizing QST data by age and sex resulted in similar components and pain sensitivity profiles. Further, these profiles are surprisingly similar to those reported in healthy populations suggesting that individual differences in pain sensitivity are a robust finding even in an older population with significant disease. PMID:27152688

  4. Human knee joint anatomy revisited: morphometry in the light of sex-specific total knee arthroplasty.

    PubMed

    Dargel, Jens; Michael, Joern W P; Feiser, Janna; Ivo, Roland; Koebke, Juergen

    2011-04-01

    This study investigates differences in the anatomy of male and female knee joints to contribute to the current debate on sex-specific total knee implants. Morphometric data were obtained from 60 human cadaver knees, and sex differences were calculated. All data were corrected for height, and male and female specimens presenting with an identical length of the femur were analyzed as matched pairs. Male linear knee joint dimensions were significantly larger when compared with females. When corrected for differences in height, medial-lateral dimensions of male knees were significantly larger than female; however, matched paired analysis did not prove these differences to be consistent. Although implant design should focus interindividual variations in knee joint anatomy, our data do not support the concept of a female-specific implant design. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Anterior knee pain after a total knee arthroplasty: What can cause this pain?

    PubMed Central

    Breugem, Stéfanus Jacob Martinus; Haverkamp, Daniël

    2014-01-01

    Total Knee Arthroplasty has been shown to be a successful procedure for treating patients with osteoarthritis, and yet approximately 5%-10% of patients experience residual pain, especially in the anterior part of the knee. Many theories have been proposed to explain the etiology of this anterior knee pain (AKP) but, despite improvements having been made, AKP remains a problem. AKP can be described as retropatellar or peripatellar pain, which limits patients in their everyday lives. Patients suffering from AKP experience difficulty in standing up from a chair, walking up and down stairs and riding a bicycle. The question asked was: “How can a ‘perfectly’ placed total knee arthroplasty (TKA) still be painful: what can cause this pain?”. To prevent AKP after TKA it is important to first identify the different anatomical structures that can cause this pain. Greater attention to and understanding of AKP should lead to significant pain relief and greater overall patient satisfaction after TKA. This article is a review of what pain is, how nerve signalling works and what is thought to cause Anterior Knee Pain after a Total Knee Arthroplasty. PMID:25035818

  6. Soft tissue artifact compensation in knee kinematics by multi-body optimization: Performance of subject-specific knee joint models.

    PubMed

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2015-11-05

    Soft tissue artifact (STA) distort marker-based knee kinematics measures and make them difficult to use in clinical practice. None of the current methods designed to compensate for STA is suitable, but multi-body optimization (MBO) has demonstrated encouraging results and can be improved. The goal of this study was to develop and validate the performance of knee joint models, with anatomical and subject-specific kinematic constraints, used in MBO to reduce STA errors. Twenty subjects were recruited: 10 healthy and 10 osteoarthritis (OA) subjects. Subject-specific knee joint models were evaluated by comparing dynamic knee kinematics recorded by a motion capture system (KneeKG™) and optimized with MBO to quasi-static knee kinematics measured by a low-dose, upright, biplanar radiographic imaging system (EOS(®)). Errors due to STA ranged from 1.6° to 22.4° for knee rotations and from 0.8 mm to 14.9 mm for knee displacements in healthy and OA subjects. Subject-specific knee joint models were most effective in compensating for STA in terms of abduction-adduction, inter-external rotation and antero-posterior displacement. Root mean square errors with subject-specific knee joint models ranged from 2.2±1.2° to 6.0±3.9° for knee rotations and from 2.4±1.1 mm to 4.3±2.4 mm for knee displacements in healthy and OA subjects, respectively. Our study shows that MBO can be improved with subject-specific knee joint models, and that the quality of the motion capture calibration is critical. Future investigations should focus on more refined knee joint models to reproduce specific OA knee geometry and physiology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Continuous passive motion and its effects on knee flexion after total knee arthroplasty in patients with knee osteoarthritis.

    PubMed

    Liao, Chun-De; Huang, Yi-Ching; Lin, Li-Fong; Chiu, Yen-Shuo; Tsai, Jui-Chen; Chen, Chun-Lung; Liou, Tsan-Hon

    2016-08-01

    This study evaluated the effects of continuous passive motion (CPM) on accelerated flexion after total knee arthroplasty (TKA) and whether CPM application measures (i.e. initial angle and daily increment) are associated with functional outcomes. A retrospective investigation was conducted at the rehabilitation centre of a university-based teaching hospital. Patients who received CPM therapy immediately after TKA surgery were categorized into rapid-, normal-, and slow-progress groups according to their response to CPM during their acute inpatient stay. Knee pain, passive knee flexion, and knee function-measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-were assessed preoperatively at discharge and at 3- and 6-month outpatient follow-up visits. A total of 354 patients were followed for 6 months after inpatient-stay discharge. The patients in the rapid-progress group (n = 119) exhibited significantly greater knee flexions than those in the slow-progress group did (n = 103) at the 3-month follow-up [mean difference (MD) = 10.3°, 95 % confidence interval (CI) 4.3°-16.3°, p < 0.001] and 6-month follow-up (MD = 10.9°, 95 % CI 6.3°-15.6°, p < 0.001). Significant WOMAC score differences between the rapid- and slow-progress groups were observed at the 3-month follow-up (MD = 7.2, 95 % CI 5.4-9.1, p < 0.001) and 6-month follow-up (MD = 16.1, 95 % CI 13.4-18.7, p < 0.001). CPM initial angles and rapid progress significantly predicted short- and long-term outcomes in knee flexion and WOMAC scores (p < 0.001). When CPM is used, early application with initial high flexion and rapid progress benefits knee function up to 6 months after TKA. II.

  8. The role of the deep medial collateral ligament in controlling rotational stability of the knee.

    PubMed

    Cavaignac, Etienne; Carpentier, Karel; Pailhé, Regis; Luyckx, Thomas; Bellemans, Johan

    2015-10-01

    The tibial insertion of the deep medial collateral ligament (dMCL) is frequently sacrificed when the proximal tibial cut is performed during total knee arthroplasty. The role of the dMCL in controlling the knee's rotational stability is still controversial. The aim of this study was to quantify the rotational laxity induced by an isolated lesion of the dMCL as it occurs during tibial preparation for knee arthroplasty. An isolated resection of the deep MCL was performed in 10 fresh-frozen cadaver knees. Rotational laxity was measured during application of a standard 5.0 N.m rotational torque. Maximal tibial rotation was measured at different knee flexion angles using an image-guided navigation system (Medivision Surgetics system, Praxim, Grenoble, France) before and after dMCL resection. In all cases, internal and external tibial rotation increased after dMCL resection. Total rotational laxity increased significantly for all knee flexion angles, with an average difference of +7.8° (SD 5.7) with the knee in extension, +8.9° (SD 1.9) in 30° flexion, +7° (SD 2.9) in 60° flexion and +5.3° (SD 2.8) in 90° flexion. Sacrificing the tibial insertion of the deep MCL increases rotational laxity of the knee by 5°-9°, depending on the knee flexion angle. Based on our findings, new surgical techniques and implants that preserve the dMCL insertion such as tibial inlay components should be developed. Further clinical evaluations are necessary.

  9. Total knee arthroplasty in a rheumatoid arthritic knee with large geode: a case report.

    PubMed

    Shih, H N; Hsu, K Y; Tan, C F; Hsueh, S; Hsu, R W

    1997-09-01

    Geodes (subchondral cysts) are a well-known manifestation of rheumatoid arthritis. Solitary cysts or cysts larger than 2 cm are not generally found in the knee joint of patients with rheumatoid arthritis (RA). We report a case of RA involving both knees with a giant geode over the right proximal tibia. Surgical treatment was performed including synovectomy, cyst enucleation and packing of autogenous bone chips followed by primary total knee arthroplasty. The postsurgical result was excellent with the knee restored to good function and complete healing of the cystic lesion.

  10. The female knee: anatomic variations.

    PubMed

    Conley, Sheryl; Rosenberg, Aaron; Crowninshield, Roy

    2007-01-01

    Traditional knee implants have been designed "down the middle,"based on the combined average size and shape of male and female knee anatomy.Sex-based research in the field of orthopaedics has led to new understanding of the anatomic differences between the sexes and the associated implications for women undergoing total knee arthroplasty. Through the use of a comprehensive bone morphology atlas that utilizes novel three-dimensional computed tomography analysis technology, significant anatomic differences have been documented in the shape and size of female knees compared with male knees. This research identifies three notable anatomic differences in the female population: a less prominent anterior condyle, an increased Q angle, and a reduced medial-lateral:anterior-posterior aspect ratio.

  11. Posterior cruciate-retaining versus posterior-stabilized total knee arthroplasty for osteoarthritis with severe varus deformity.

    PubMed

    Ünkar, Ethem Ayhan; Öztürkmen, Yusuf; Şükür, Erhan; Çarkçı, Engin; Mert, Murat

    2017-03-01

    The aim of this study was to compare the radiological and functional results of posterior cruciate ligament (PCL) - retaining and posterior-stabilized total knee arthroplasties in patients with severe varus gonarthrosis. Medical records of 112 knees of 96 patients who underwent total knee arthroplasty for severe varus (≥15°) were reviewed. PCL-retaining and PCL-stabilizing groups consisted of 58 and 54 knees, respectively. Mean follow-up time was 56.6 months (range: 24-112 months). Knee Society (KS) clinical rating system was used in clinical evaluation. Range of motion, degree of flexion contracture, postoperative alignment, and complication rates were compared between the groups. Mean preoperative mechanical tibiofemoral angle was 20.1° in varus alignment, and was restored to 4.6° in valgus postoperatively. No statistically significant differences were found between PCL-stabilizing and PCL-retaining groups when KS knee scores, function scores, and flexion arc were evaluated. Two patients in PCL-retaining group underwent revision surgery due to aseptic loosening of tibial component. One patient in PCL-stabilizing group needed arthrotomy due to patellar clunk syndrome. There were no notable differences between the 2 groups and PCL-retaining design had outcomes as good as PCL-stabilizing total knee implant in osteoarthritic knees with severe varus deformity. Level III, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  12. Design comparison: manipulation after total knee arthroplasty.

    PubMed

    Rogers, Jason M; Patel, Kevin V; Barnes, C Lowry

    2015-01-01

    Postoperative stiffness is a relatively uncommon issue in total knee arthroplasty (TKA). However, it can be a debilitating complication when it occurs. Manipulation under anesthesia (MUA) is commonly used as the primary treatment modality following failed physiotherapy. The Advance medial pivot knee (Wright Medical Technology) was created in an effort to prevent stiffness postoperatively and increase range of motion. The Evolution medial pivot knee is a second-generation design that builds on the technology of the Advance knee. This article presents a retrospective review of prospectively collected data on 881 primary medial pivot knees (592 Advance knees, 289 Evolution knees). It was theorized that the design changes made to the Evolution knees might contribute toward reducing the need for MUA. It was found that the Evolution knees required significantly fewer manipulations under anesthesia (p = .036). The design modifications made to the Evolution knees may have contributed to the lower rate of MUA.

  13. Subject-Specific Modeling of Muscle Force and Knee Contact in Total Knee Arthroplasty

    PubMed Central

    Navacchia, Alessandro; Rullkoetter, Paul J.; Schütz, Pascal; List, Renate B.; Fitzpatrick, Clare K.; Shelburne, Kevin B.

    2017-01-01

    Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal–external rotation, joint load, and tibial insert conformity. PMID:26792665

  14. The effect of exercise therapy on knee adduction moment in individuals with knee osteoarthritis: A systematic review.

    PubMed

    Ferreira, Giovanni E; Robinson, Caroline Cabral; Wiebusch, Matheus; Viero, Carolina Cabral de Mello; da Rosa, Luis Henrique Telles; Silva, Marcelo Faria

    2015-07-01

    Exercise therapy is an evidence-based intervention for the conservative management of knee osteoarthritis. It is hypothesized that exercise therapy could reduce the knee adduction moment. A systematic review was performed in order to verify the effects of exercise therapy on the knee adduction moment in individuals with knee osteoarthritis in studies that also assessed pain and physical function. A comprehensive electronic search was performed on MEDLINE, Cochrane CENTRAL, EMBASE, Google scholar and OpenGrey. Inclusion criteria were randomized controlled trials with control or sham groups as comparator assessing pain, physical function, muscle strength and knee adduction moment during walking at self-selected speed in individuals with knee osteoarthritis that underwent a structured exercise therapy rehabilitation program. Two independent reviewers extracted the data and assessed risk of bias. For each study, knee adduction moment, pain and physical function outcomes were extracted. For each outcome, mean differences and 95% confidence intervals were calculated. Due to clinical heterogeneity among exercise therapy protocols, a descriptive analysis was chosen. Three studies, comprising 233 participants, were included. None of the studies showed significant differences between strengthening and control/sham groups in knee adduction moment. In regards to pain and physical function, the three studies demonstrated significant improvement in pain and two of them showed increased physical function following exercise therapy compared to controls. Muscle strength and torque significantly improved in all the three trials favoring the intervention group. Clinical benefits from exercise therapy were not associated with changes in the knee adduction moment. The lack of knee adduction moment reduction indicates that exercise therapy may not be protective in knee osteoarthritis from a joint loading point of view. Alterations in neuromuscular control, not captured by the knee

  15. Effects of proprioceptive circuit exercise on knee joint pain and muscle function in patients with knee osteoarthritis.

    PubMed

    Ju, Sung-Bum; Park, Gi Duck; Kim, Sang-Soo

    2015-08-01

    [Purpose] This study applied proprioceptive circuit exercise to patients with degenerative knee osteoarthritis and examined its effects on knee joint muscle function and the level of pain. [Subjects] In this study, 14 patients with knee osteoarthritis in two groups, a proprioceptive circuit exercise group (n = 7) and control group (n = 7), were examined. [Methods] IsoMed 2000 (D&R Ferstl GmbH, Hemau, Germany) was used to assess knee joint muscle function, and a Visual Analog Scale was used to measure pain level. [Results] In the proprioceptive circuit exercise group, knee joint muscle function and pain levels improved significantly, whereas in the control group, no significant improvement was observed. [Conclusion] A proprioceptive circuit exercise may be an effective way to strengthen knee joint muscle function and reduce pain in patients with knee osteoarthritis.

  16. Application of the Ottawa Knee Rules in assessing acute knee injuries.

    PubMed

    O'Sullivan, M J A; O'Sullivan, I

    2006-01-01

    The Ottawa Knee Rules (OKR) were established to identify which adults with acute knee injuries require knee x-rays as part of their assessment. This study evaluates the compliance of non-consultant hospital doctors (NCHDs), working in an Irish Emergency Dept., with these guidelines and assesses the impact of raising the profile of these rules on their implementation. Emergency Dept. (ED) notes of all adults who presented with an acute knee injury in a 3-month period were analysed retrospectively and compliance with the OKR was assessed. ED NCHDs were then educated on the details and value of these guidelines. In the subsequent three months, the improvement in compliance with the OKR was audited. In the initial audit, according to the Ottawa criteria, 65.5% of all x-rays of acute knee injuries were performed unnecessarily. In the second audit, performed after increasing awareness of the OKR, this figure had dropped to 39.1%. The NCHDs involved in this project cited 'patient expectation' for an x-ray as the primary reason why full compliance was not achieved. This study highlights a lack of awareness of and compliance with the OKR in the assessment of acute knee injuries in adults. It shows how the implementation of simple measures, which raised the profile of the OKR among ED staff, significantly improved compliance with the rules, thus cutting patient waiting times and cutting hospital costs. Futhermore, this study revealed that patients, when injured, expect to get x-rayed and ofter doctors comply with these expectations even if no indication exists.

  17. Effect of rocker-soled shoes on parameters of knee joint load in knee osteoarthritis.

    PubMed

    Madden, Elizabeth G; Kean, Crystal O; Wrigley, Tim V; Bennell, Kim L; Hinman, Rana S

    2015-01-01

    This study evaluated the immediate effects of rocker-soled shoes on parameters of the knee adduction moment (KAM) and pain in individuals with knee osteoarthritis (OA). Three-dimensional gait analysis was performed on 30 individuals (mean (SD): age, 61 (7) yr; 15 (50%) male) with radiographic and symptomatic knee OA under three walking conditions in a randomized order: i) wearing rocker-soled shoes (Skechers Shape-ups), ii) wearing non-rocker-soled shoes (ASICS walking shoes), and iii) barefoot. Peak KAM and KAM angular impulse were measured as primary indicators of knee load distribution. Secondary measures included the knee flexion moment (KFM) and knee pain during walking. Peak KAM was significantly lower when wearing the rocker-soled shoes compared with that when wearing the non-rocker-soled shoes (mean difference (95% confidence interval), -0.27 (-0.42 to -0.12) N·m/BW × Ht%; P < 0.001). Post hoc tests revealed no significant difference in KAM impulse between rocker-soled and non-rocker-soled shoe conditions (P = 0.13). Both peak KAM and KAM impulse were significantly higher during both shoe conditions compared with those during the barefoot condition (P < 0.001). There were no significant differences in KFM (P = 0.36) or knee pain (P = 0.89) between conditions. Rocker-soled shoes significantly reduced peak KAM when compared with non-rocker-soled shoes, without a concomitant change in KFM, and thus may potentially reduce medial knee joint loading. However, KAM parameters in the rocker-soled shoes remained significantly higher than those during barefoot walking. Wearing rocker-soled shoes did not have a significant immediate effect on walking pain. Further research is required to evaluate whether rocker-soled shoes can influence symptoms and progression of knee OA with prolonged wear.

  18. Knee Osteoarthritis Treatment with the KineSpring Knee Implant System: A Report of Two Cases

    PubMed Central

    Hayes, David A.; Miller, Larry E.; Block, Jon E.

    2012-01-01

    Osteoarthritis (OA) is a leading cause of disability in middle-aged and older adults with the prevalence expected to increase by 40% by 2025. This dramatic projected increase in OA reflects, in large part, the alarming obesity epidemic. Indeed, it is now well understood that abnormal loading across the knee joint due to malalignment and/or excessive weight gain is responsible for accelerating OA progression. Consequently, there is a therapeutic need for alternative knee OA treatments that directly address joint overload to fill the gap between ineffective conservative care and invasive joint-modifying surgical procedures. We describe two cases that presented with bilateral knee OA resistant to conservative treatments, each with one knee previously and unsuccessfully treated with high tibial osteotomy to improve alignment and the contralateral knee successfully treated with a joint-preserving, load-absorbing implant (KineSpring Knee Implant System). PMID:23304590

  19. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    PubMed

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  20. Articular Cartilage of the Human Knee Joint: In Vivo Multicomponent T2 Analysis at 3.0 T

    PubMed Central

    Choi, Kwang Won; Samsonov, Alexey; Spencer, Richard G.; Wilson, John J.; Block, Walter F.; Kijowski, Richard

    2015-01-01

    Purpose To compare multicomponent T2 parameters of the articular cartilage of the knee joint measured by using multicomponent driven equilibrium single-shot observation of T1 and T2 (mcDESPOT) in asymptomatic volunteers and patients with osteoarthritis. Materials and Methods This prospective study was performed with institutional review board approval and with written informed consent from all subjects. The mcDESPOT sequence was performed in the knee joint of 13 asymptomatic volunteers and 14 patients with osteoarthritis of the knee. Single-component T2 (T2Single), T2 of the fast-relaxing water component (T2F) and of the slow-relaxing water component (T2S), and the fraction of the fast-relaxing water component (FF) of cartilage were measured. Wilcoxon rank-sum tests and multivariate linear regression models were used to compare mcDESPOT parameters between volunteers and patients with osteoarthritis. Receiver operating characteristic analysis was used to assess diagnostic performance with mcDESPOT parameters for distinguishing morphologically normal cartilage from morphologically degenerative cartilage identified at magnetic resonance imaging in eight cartilage subsections of the knee joint. Results Higher cartilage T2Single (P < .001), lower cartilage FF (P < .001), and similar cartilage T2F (P = .079) and T2S (P = .124) values were seen in patients with osteoarthritis compared with those in asymptomatic volunteers. Differences in T2Single and FF remained significant (P < .05) after consideration of age differences between groups of subjects. Diagnostic performance was higher with FF than with T2Single for distinguishing between normal and degenerative cartilage (P < .05), with greater areas under the curve at receiver operating characteristic analysis. Conclusion Patients with osteoarthritis of the knee had significantly higher cartilage T2Single and significantly lower cartilage FF than did asymptomatic volunteers, and receiver operating characteristic analysis

  1. Improvements in knee biomechanics during walking are associated with increased physical activity after total knee arthroplasty.

    PubMed

    Arnold, John B; Mackintosh, Shylie; Olds, Timothy S; Jones, Sara; Thewlis, Dominic

    2015-12-01

    Total knee arthroplasty (TKA) in people with knee osteoarthritis increases knee-specific and general physical function, but it has not been established if there is a relationship between changes in these elements of functional ability. This study investigated changes and relationships between knee biomechanics during walking, physical activity, and use of time after TKA. Fifteen people awaiting TKA underwent 3D gait analysis before and six months after surgery. Physical activity and use of time were determined in free-living conditions from a high resolution 24-h activity recall. After surgery, participants displayed significant improvements in sagittal plane knee biomechanics and improved their physical activity profiles, standing for 105 more minutes (p=0.001) and performing 64 min more inside chores on average per day (p=0.008). Changes in sagittal plane knee range of motion (ROM) and peak knee flexion positively correlated with changes in total daily energy expenditure, time spent undertaking moderate to vigorous physical activity, inside chores and passive transport (r=0.52-0.66, p=0.005-0.047). Restoration of knee function occurs in parallel and is associated with improvements in physical activity and use of time after TKA. Increased functional knee ROM is required to support improvements in total and context specific physical activity. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Effects of static stretching of knee musculature on patellar alignment and knee functional disability in male patients diagnosed with knee extension syndrome: A single-group, pretest-posttest trial.

    PubMed

    Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Hesampour, Kazem; Shah-Hosseini, Gholam Reza; Jamshidi, Ali Ashraf; Shamsi, Mohammad Bagher

    2016-04-01

    Knee extension (Kext) syndrome is based on movement system impairments and is described as knee pain associated with quadriceps stiffness. To investigate the effects of 3 times per week for 4 weeks static stretching of knee musculature on patellar alignment and knee functional disability in male Kext syndrome patients. A single-group, pretest-posttest clinical trial. Hazrat-e-Rasoul Akram Hospital. Forty-six male Kext syndrome patients aged 18-35 years. Knee functional disability was assessed by the Kujala questionnaire. Patellar tilt was assessed using the skyline view X-ray. In addition, patella alta was assessed by X-ray using the Insall-Salvati ratio. After intervention, changes in knee flexion-extension range of motion (ROM) and hip adduction were assessed by goniometer and inclinometer. Changes in patellar tilt and patella alta were evaluated. Correlations between muscles length, patellar tilt and knee functional disability were also evaluated. The mean of patellar tilt in male Kext syndrome patients was 15.19°. Only the correlation between rectus femoris shortness and patellar tilt (P = 0.002) and the correlation between rectus femoris shortness and knee functional disability (P = 0.037) were significant. Patella alta was not severe in male Kext syndrome patients (1.28 ± 0.10). Knee flexion-extension ROM and femoral adduction increased significantly after a 12-session stretching programme (P < 0.0001). The results demonstrated that rectus femoris shortness had higher correlation with patellar tilt and knee functional disability than iliotibial band and hamstring shortness. Stretching was effective in reducing patellar tilt, patella alta, knee functional disability, increasing knee ROM and hip adduction in these patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Platelet-rich plasma (PRP) for knee disorders

    PubMed Central

    Shahid, Mohammad; Kundra, Rik

    2017-01-01

    Platelet-rich plasma (PRP) is an autologous blood product with platelet concentrations above baseline values. The process involves the extraction of blood from the patient which is then centrifuged to obtain a concentrated suspension of platelets by plasmapheresis. It then undergoes a two-stage centrifugation process to separate the solid and liquid components of the anticoagulated blood. PRP owes its therapeutic use to the growth factors released by the platelets which are claimed to possess multiple regenerative properties. In the knee, PRP has been used in patients with articular cartilage pathology, ligamentous and meniscal injuries. There is a growing body of evidence to support its use in selected indications and this review looks at the most recent evidence. We also look at the current UK National Institute of Health & Clinical Excellence (NICE) guidelines with respect to osteoarthritis and the use of PRP in the knee. Cite this article: EFORT Open Rev 2017;2:28–34. DOI: 10.1302/2058-5241.2.160004. PMID:28607768

  4. The effect of thigh muscle activity on anterior knee laxity in the uninjured and anterior cruciate ligament-injured knee.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C; Milligan, Peter; Amis, Andrew A

    2014-11-01

    The main purpose of this study was to describe the nature of the relationship between hamstring muscle activity and anterior knee laxity. This was a cross-sectional study. Anterior knee laxity was measured at 133N and manual maximal forces using the KT2000 knee arthrometer, in 8 ACL-injured and 13 uninjured individuals. Electromyographic activity of the lateral hamstrings was measured during laxity testing. Subjects contracted the hamstrings during anterior knee laxity testing at eight predetermined levels of maximal voluntary isometric contraction. Volitional contraction of the lateral hamstrings reduced anterior knee laxity logarithmically for both the 133N and manual maximal tests in both the ACL-injured and uninjured knees. A simple linear regression model, with the log of percentage of maximum lateral hamstrings activity as the sole predictor, explained approximately 70-80% of the variation in anterior knee laxity. Both ACL-injured and uninjured subjects reduced anterior knee laxity at the same rate with increases in muscle activity. However, initial lateral hamstrings muscle activity had a greater effect on percentage anterior knee laxity scores in the ACL-injured as compared to the uninjured knee. Lateral hamstrings activity reduces anterior knee laxity in a nonlinear manner, whereby the initial lower level of activation produces the greatest change in anterior knee laxity. Therefore, hamstrings muscle activity must be monitored during anterior knee laxity testing.

  5. Taking care of your new knee joint

    MedlinePlus

    Knee arthroplasty - precautions; Knee replacement - precautions ... After you have knee replacement surgery , you will need to be careful about how you move your knee, especially for the first few ...

  6. Cross-sectional and Longitudinal Associations between Knee Joint Effusion Synovitis and Knee Pain in Older Adults.

    PubMed

    Wang, Xia; Jin, Xingzhong; Han, Weiyu; Cao, Yuelong; Halliday, Andrew; Blizzard, Leigh; Pan, Faming; Antony, Benny; Cicuttini, Flavia; Jones, Graeme; Ding, Changhai

    2016-01-01

    To describe the cross-sectional and longitudinal associations between knee regional effusion synovitis and knee pain in older adults. Data from a population-based random sample (n = 880, mean age 62 yrs, 50% women) were used. Baseline knee joint effusion synovitis was graded (0-3) using T2-weighted magnetic resonance imaging (MRI) in the suprapatellar pouch, central portion, posterior femoral recess, and subpopliteal recess. Effusion synovitis of the whole joint was defined as a score of ≥ 2 in any subregion. Other knee structural (including cartilage, bone marrow, and menisci) lesions were assessed by MRI at baseline. Knee pain was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index questionnaire at baseline and 2.6 years later. Multivariable analyses were performed after adjustment for age, sex, body mass index, and other structural lesions. The prevalence of effusion synovitis was 67%. Suprapatellar pouch effusion synovitis was significantly and independently associated with increased total and nonweight-bearing knee pain in both cross-sectional and longitudinal analyses (for an increase in total knee pain of ≥ 5, RR 1.26 per grade, 95% CI 1.04-1.52), and increased weight-bearing knee pain in longitudinal analysis only. Effusion synovitis in posterior femoral recess and central portion were independently associated with increases in nonweight-bearing pain (RR 1.63 per grade, 95% CI 1.32-2.01 and RR 1.29 per grade, 95% CI 1.01-1.65, respectively) in longitudinal analyses only. Knee joint effusion synovitis has independent associations with knee pain in older adults. Suprapatellar pouch effusion synovitis is associated with nonweight-bearing and weight-bearing knee pain, while posterior femoral recess and central portion effusion synovitis are only associated with nonweight-bearing pain.

  7. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  8. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  9. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  10. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    PubMed

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and

  11. Cryotherapy impairs knee joint position sense.

    PubMed

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. Georg Thieme Verlag KG Stuttgart.New York.

  12. Knee contact forces are not altered in early knee osteoarthritis.

    PubMed

    Meireles, S; De Groote, F; Reeves, N D; Verschueren, S; Maganaris, C; Luyten, F; Jonkers, I

    2016-03-01

    This study calculated knee contact forces (KCF) and its relations with knee external knee adduction moments (KAM) and/or flexion moments (KFM) during the stance phase of gait in patients with early osteoarthritis (OA), classified based on early joint degeneration on Magnetic Resonance Imaging (MRI). We aimed at assessing if altered KCF are already present in early structural degeneration. Three-dimensional motion and ground reaction force data in 59 subjects with medial compartment knee OA (N=23 established OA, N=16 early OA, N=20 controls) were used as input for a musculoskeletal model. KAM and KFM, and KCF were estimated using OpenSim software. No significant differences were found between controls and subjects with early OA. In early OA patients, KAM significantly explained 69% of the variance associated with the first peaks KCF but only KFM contributed to the second peaks KCF. The multiple correlation, combining KAM and KFM, showed to be higher. However, only 20% of the variance of second peak KCF was explained by both moments in established OA. KCF are not increased in patients with early OA, suggesting that knee joint overload is more a consequence of further joint degeneration in more advanced stages of OA. Additionally, our results clearly show that KAM is not sufficient to predict joint loading at the end of the stance, where KFM contributes substantially to the loading, especially in early OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Automatic locking orthotic knee device

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  14. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure.

    PubMed

    Pagenstert, Geert; Hintermann, Beat

    2011-10-13

    Simultaneous osteoarthritis (OA) of the ankle joint complicates primary total knee arthroplasty (TKA). In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA) during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week) and hospital stay (12 days) of this special patient was markedly reduced compared to the usual course of separate TJA. Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  15. Total or Partial Knee Arthroplasty Trial - TOPKAT: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background In the majority of patients with osteoarthritis of the knee the disease originates in the medial compartment. There are two fundamentally different approaches to knee replacement for patients with unicompartmental disease: some surgeons feel that it is always best to replace both the knee compartments with a total knee replacement (TKR); whereas others feel it is best to replace just the damaged component of the knee using a partial or unicompartment replacement (UKR). Both interventions are established and well-documented procedures. Little evidence exists to prove the clinical and cost-effectiveness of either management option. This provides an explanation for the high variation in treatment of choice by individual surgeons for the same knee pathology. The aim of the TOPKAT study will be to assess the clinical and cost effectiveness of TKRs compared to UKRs in patients with medial compartment osteoarthritis. Methods/Design The design of the study is a single layer multicentre superiority type randomised controlled trial of unilateral knee replacement patients. Blinding will not be possible as the surgical scars for each procedure differ. We aim to recruit 500 patients from approximately 28 secondary care orthopaedic units from across the UK including district general and teaching hospitals. Participants will be randomised to either UKR or TKR. Randomisation will occur using a web-based randomisation system. The study is pragmatic in terms of implant selection for the knee replacement operation. Participants will be followed up for 5 years. The primary outcome is the Oxford Knee Score, which will be collected via questionnaires at 2 months, 1 year and then annually to 5 years. Secondary outcomes will include cost-effectiveness, patient satisfaction and complications data. Trial registration Current Controlled Trials ISRCTN03013488; ClinicalTrials.gov Identifier: NCT01352247 PMID:24028414

  16. The influence of arch supports on knee torques relevant to knee osteoarthritis.

    PubMed

    Franz, Jason R; Dicharry, Jay; Riley, Patrick O; Jackson, Keith; Wilder, Robert P; Kerrigan, D Casey

    2008-05-01

    Changes in footwear and foot orthotic devices have been shown to significantly alter knee joint torques thought to be relevant to the progression if not the development of knee osteoarthritis (OA) in the medial tibiofemoral compartment. The purpose of this study was to determine if commonly prescribed arch support cushions promote a medial force bias during gait similar to medial-wedged orthotics, thereby increasing knee varus torque during both walking and running. Twenty-two healthy, physically active young adults (age, 29.2 +/- 5.1 yr) were analyzed at their self-selected walking and running speeds in control shoes with and without arch support cushions. Three-dimensional motion capture data were collected in synchrony with ground reaction force (GRF) data collected from an instrumented treadmill. Peak external knee varus torque during walking and running were calculated through a full inverse dynamic model and compared. Peak knee varus torque was statistically significantly increased by 6% (0.01 +/- 0.02 N.m.(kg.m)(-1)) in late stance during walking and by 4% (0.03 +/- 0.03 N.m.(kg.m)(-1)) during running with the addition of arch support cushions. The addition of material under the medial aspect of the foot by way of a flexible arch support promotes a medial force bias during walking and running, significantly increasing knee varus torque. These findings suggest that discretion be employed with regard to the prescription of commonly available orthotic insoles like arch support cushions.

  17. [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

    PubMed

    Jenny, J Y; Boeri, C

    2001-01-01

    A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

  18. Prosthetic knee design by simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollerbach, K; Hollister, A

    1999-07-30

    Although 150,000 total knee replacement surgeries are performed annually in North America, current designs of knee prostheses have mechanical problems that include a limited range of motion, abnormal gait patterns, patellofemoral joint dysfunction, implant loosening or subsidence, and excessive wear. These problems fall into three categories: failure to reproduce normal joint kinematics, which results in altered limb function; bone-implant interface failure; and material failure. Modern computer technology can be used to design, prototype, and test new total knee implants. The design team uses the full range of CAD-CAM to design and produce implant prototypes for mechanical and clinical testing. Closermore » approximation of natural knee kinematics and kinetics is essential for improved patient function and diminished implant loads. Current knee replacement designs are based on 19th Century theories that the knee moves about a variable axis of rotation. Recent research has shown, however, that knee motion occurs about two fixed, offset axes of rotation. These aces are not perpendicular to the long axes of the bones or to each other, and the axes do not intersect. Bearing surfaces of mechanisms that move about axes of rotation are surfaces of revolution of those axes which advanced CAD technology can produce. Solids with surfaces of revolution for the two axes of rotation for the knee have been made using an HP9000 workstation and Structural Ideas Master Series CAD software at ArthroMotion. The implant's CAD model should closely replicate movements of the normal knee. The knee model will have a range of flexion-extension (FE) from -5 to 120 degrees. Movements include varus, valgus, internal and external rotation, as well as flexion and extension. The patellofemoral joint is aligned perpendicular to the FE axis and replicates the natural joint more closely than those of existing prostheses. The bearing surfaces will be more congruent than current designs and should

  19. The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology: Review Article.

    PubMed

    Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio; Lepri, Andrea Cozzi; Sirleo, Luigi; Innocenti, Massimo

    2017-02-01

    Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. We performed a review of national joint registries trying to answer the following questions: "Which is the main factor directly related to revisions rate in TKA?" and "Are there new bearing options better than conventional ones?" A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.

  20. Arthroscopic knee anatomy in young achondroplasia patients

    PubMed Central

    del Pilar Duque Orozco, M.; Record, N. C.; Rogers, K. J; Bober, M. B.; Mackenzie, W. G.; Atanda, A.

    2017-01-01

    Abstract Purpose Achondroplasia is the most common form of skeletal dysplasia, affecting more than 250 000 individuals worldwide. In these patients, the developing knee undergoes multiple anatomical changes. The purpose of this study was to characterise the intra-articular knee anatomy in children with achondroplasia who underwent knee arthroscopy. Methods Records of achondroplasia patients who underwent knee arthroscopy between 2009 and 2014 were reviewed. Demographic data, operative reports, follow-up notes, MRI and arthroscopy images were reviewed. Bony, cartilaginous and ligamentous changes were noted. The trochlea sulcus angle was measured from intra-operative arthroscopic images. Results A total of 12 knee arthroscopies in nine patients were performed. The mean age at surgery was 16.9 years (12 to 22). In all patients, the indication for surgery was knee pain and/or mechanical symptoms that were refractory to non-operative treatment. Three anatomical variations involving the distal femur were found in all knees: a deep femoral trochlea; a high A-shaped intercondylar notch; and a vertically oriented anterior cruciate ligament. The average trochlea sulcus angle measured 123°. Pathology included: synovial plica (one knee); chondral lesions (three knees); discoid lateral meniscus (11 knees); and meniscal tears (six knees). All patients were pain-free and returned to normal activity at final follow-up. Conclusion Children with achondroplasia have characteristic distal femur anatomy noted during knee arthroscopy. These variations should be considered normal during knee arthroscopy in these patients. Arthroscopic findings confirmed previous MRI findings within this specific population with the addition of a deep trochlear groove which was not previously reported. PMID:28828058