Sample records for uhv sample transfer

  1. UHV LT-STM system with Sample and Tip Exchange

    NASA Astrophysics Data System (ADS)

    Dreyer, Michael; Lee, Jonghee; Wang, Hui; Sullivan, Dan; Barker, Barry

    2006-03-01

    We developed and built a low temperature scanning tunneling microscope system with ultra high vacuum sample and tip preparation capabilities. The STM is mounted inside an UHV can which is submerged in a He bath cryostat. The cryostat is equipped with two superconducting magnets allowing a maximum in plane field of 2 T and a maximum out of plane field of 9 T. The two fields can be combined to a 1 T vector field. The vacuum can is connected to an UHV system at room temperature consisting of two chambers: One dedicated to transferring samples and tips to the STM, and the other chamber used for tip/sample preparation. It is equipped with two electron beam evaporators, an argon ion sputter gun as well as sample heaters. The whole system is supported by an optical table to decouple the STM from building vibrations. The system was successfully used to study standing electron waves on gold (111) as well as vortices on NbSe2. Details of the microscope, sample and tip handling system, as well as the UHV system will be presented.

  2. A versatile UHV transport and measurement chamber for neutron reflectometry under UHV conditions.

    PubMed

    Syed Mohd, A; Pütter, S; Mattauch, S; Koutsioubas, A; Schneider, H; Weber, A; Brückel, T

    2016-12-01

    We report on a versatile mini ultra-high vacuum (UHV) chamber which is designed to be used on the MAgnetic Reflectometer with high Incident Angle of the Jülich Centre for Neutron Science at Heinz Maier-Leibnitz Zentrum in Garching, Germany. Samples are prepared in the adjacent thin film laboratory by molecular beam epitaxy and moved into the compact chamber for transfer without exposure to ambient air. The chamber is based on DN 40 CF flanges and equipped with sapphire view ports, a small getter pump, and a wobble stick, which serves also as sample holder. Here, we present polarized neutron reflectivity measurements which have been performed on Co thin films at room temperature in UHV and in ambient air in a magnetic field of 200 mT and in the Q-range of 0.18 Å -1 . The results confirm that the Co film is not contaminated during the polarized neutron reflectivity measurement. Herewith it is demonstrated that the mini UHV transport chamber also works as a measurement chamber which opens new possibilities for polarized neutron measurements under UHV conditions.

  3. A versatile UHV transport and measurement chamber for neutron reflectometry under UHV conditions

    NASA Astrophysics Data System (ADS)

    Syed Mohd, A.; Pütter, S.; Mattauch, S.; Koutsioubas, A.; Schneider, H.; Weber, A.; Brückel, T.

    2016-12-01

    We report on a versatile mini ultra-high vacuum (UHV) chamber which is designed to be used on the MAgnetic Reflectometer with high Incident Angle of the Jülich Centre for Neutron Science at Heinz Maier-Leibnitz Zentrum in Garching, Germany. Samples are prepared in the adjacent thin film laboratory by molecular beam epitaxy and moved into the compact chamber for transfer without exposure to ambient air. The chamber is based on DN 40 CF flanges and equipped with sapphire view ports, a small getter pump, and a wobble stick, which serves also as sample holder. Here, we present polarized neutron reflectivity measurements which have been performed on Co thin films at room temperature in UHV and in ambient air in a magnetic field of 200 mT and in the Q-range of 0.18 Å-1. The results confirm that the Co film is not contaminated during the polarized neutron reflectivity measurement. Herewith it is demonstrated that the mini UHV transport chamber also works as a measurement chamber which opens new possibilities for polarized neutron measurements under UHV conditions.

  4. Sample mounting and transfer for coupling an ultrahigh vacuum variable temperature beetle scanning tunneling microscope with conventional surface probes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nafisi, Kourosh; Ranau, Werner; Hemminger, John C.

    2001-01-01

    We present a new ultrahigh vacuum (UHV) chamber for surface analysis and microscopy at controlled, variable temperatures. The new instrument allows surface analysis with Auger electron spectroscopy, low energy electron diffraction, quadrupole mass spectrometer, argon ion sputtering gun, and a variable temperature scanning tunneling microscope (VT-STM). In this system, we introduce a novel procedure for transferring a sample off a conventional UHV manipulator and onto a scanning tunneling microscope in the conventional ''beetle'' geometry, without disconnecting the heating or thermocouple wires. The microscope, a modified version of the Besocke beetle microscope, is mounted on a 2.75 in. outer diameter UHVmore » flange and is directly attached to the base of the chamber. The sample is attached to a tripod sample holder that is held by the main manipulator. Under UHV conditions the tripod sample holder can be removed from the main manipulator and placed onto the STM. The VT-STM has the capability of acquiring images between the temperature range of 180--500 K. The performance of the chamber is demonstrated here by producing an ordered array of island vacancy defects on a Pt(111) surface and obtaining STM images of these defects.« less

  5. Combined UHV/high-pressure catalysis setup for depth-resolved near-surface spectroscopic characterization and catalytic testing of model catalysts

    NASA Astrophysics Data System (ADS)

    Mayr, Lukas; Rameshan, Raffael; Klötzer, Bernhard; Penner, Simon; Rameshan, Christoph

    2014-05-01

    An ultra-high vacuum (UHV) setup for "real" and "inverse" model catalyst preparation, depth-resolved near-surface spectroscopic characterization, and quantification of catalytic activity and selectivity under technologically relevant conditions is described. Due to the all-quartz reactor attached directly to the UHV-chamber, transfer of the catalyst for in situ testing without intermediate contact to the ambient is possible. The design of the UHV-compatible re-circulating batch reactor setup allows the study of reaction kinetics under close to technically relevant catalytic conditions up to 1273 K without contact to metallic surfaces except those of the catalyst itself. With the attached differentially pumped exchangeable evaporators and the quartz-microbalance thickness monitoring equipment, a reproducible, versatile, and standardised sample preparation is possible. For three-dimensional near-surface sample characterization, the system is equipped with a hemispherical analyser for X-ray photoelectron spectroscopy (XPS), electron-beam or X-ray-excited Auger-electron spectroscopy, and low-energy ion scattering measurements. Due the dedicated geometry of the X-ray gun (54.7°, "magic angle") and the rotatable sample holder, depth analysis by angle-resolved XPS measurements can be performed. Thus, by the combination of characterisation methods with different information depths, a detailed three-dimensional picture of the electronic and geometric structure of the model catalyst can be obtained. To demonstrate the capability of the described system, comparative results for depth-resolved sample characterization and catalytic testing in methanol steam reforming on PdGa and PdZn near-surface intermetallic phases are shown.

  6. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstratedmore » by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.« less

  7. A fibre-coupled UHV-compatible variable angle reflection-absorption UV/visible spectrometer

    NASA Astrophysics Data System (ADS)

    Stubbing, J. W.; Salter, T. L.; Brown, W. A.; Taj, S.; McCoustra, M. R. S.

    2018-05-01

    We present a novel UV/visible reflection-absorption spectrometer for determining the refractive index, n, and thicknesses, d, of ice films. Knowledge of the refractive index of these films is of particular relevance to the astrochemical community, where they can be used to model radiative transfer and spectra of various regions of space. In order to make these models more accurate, values of n need to be recorded under astronomically relevant conditions, that is, under ultra-high vacuum (UHV) and cryogenic cooling. Several design considerations were taken into account to allow UHV compatibility combined with ease of use. The key design feature is a stainless steel rhombus coupled to an external linear drive (z-shift) allowing a variable reflection geometry to be achieved, which is necessary for our analysis. Test data for amorphous benzene ice are presented as a proof of concept, the film thickness, d, was found to vary linearly with surface exposure, and a value for n of 1.43 ± 0.07 was determined.

  8. High pressure reaction cell and transfer mechanism for ultrahigh vacuum spectroscopic chambers

    NASA Astrophysics Data System (ADS)

    Nelson, A. E.; Schulz, K. H.

    2000-06-01

    A novel high pressure reaction cell and sample transfer mechanism for ultrahigh vacuum (UHV) spectroscopic chambers is described. The design employs a unique modification of a commercial load-lock transfer system to emulate a tractable microreactor. The reaction cell has an operating pressure range of <1×10-4 to 1000 Torr and can be evacuated to UHV conditions to enable sample transfer into the spectroscopic chamber. Additionally, a newly designed sample holder equipped with electrical and thermocouple contacts is described. The sample holder is capable of resistive specimen heating to 400 and 800 °C with current requirements of 14 A (2 V) and 25 A (3.5 V), respectively. The design enables thorough material science characterization of catalytic reactions and the surface chemistry of catalytic materials without exposing the specimen to atmospheric contaminants. The system is constructed primarily from readily available commercial equipment allowing its rapid implementation into existing laboratories.

  9. The design and implementation of on-line monitoring system for UHV compact shunt capacitors

    NASA Astrophysics Data System (ADS)

    Tao, Weiliang; Ni, Xuefeng; Lin, Hao; Jiang, Shengbao

    2017-08-01

    Because of the large capacity and compact structure of the UHV compact shunt capacitor, it is difficult to take effective measures to detect and prevent the faults. If the fault capacitor fails to take timely maintenance, it will pose a threat to the safe operation of the system and the life safety of the maintenance personnel. The development of UHV compact shunt capacitor on-line monitoring system can detect and record the on-line operation information of UHV compact shunt capacitors, analyze and evaluate the early fault warning signs, find out the fault capacitor or the capacitor with fault symptom, to ensure safe and reliable operation of the system.

  10. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability.

    PubMed

    Kim, Jungdae; Nam, Hyoungdo; Qin, Shengyong; Kim, Sang-ui; Schroeder, Allan; Eom, Daejin; Shih, Chih-Kang

    2015-09-01

    We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper and stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.

  11. Operational adaptability evaluation index system of pumped storage in UHV receiving-end grids

    NASA Astrophysics Data System (ADS)

    Yuan, Bo; Zong, Jin; Feng, Junshu

    2017-01-01

    Pumped storage is an effective solution to deal with the emergency reserve shortage, renewable energy accommodating and peak-shaving problems in ultra-high voltage (UHV) transmission receiving-end grids. However, governments and public opinion in China tend to evaluate the operational effectiveness of pumped storage using annual utilization hour, which may result in unreasonable and unnecessary dispatch of pumped storage. This paper built an operational adaptability evaluation index system for pumped storage in UHV-receiving end grids from three aspects: security insurance, peak-shaving and renewable energy accommodating, which can provide a comprehensive and objective way to evaluate the operational performance of a pumped storage station.

  12. Uhv compatible chopper system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voss, D.E.; Cohen, S.A.

    1979-11-01

    A time-of-flight system utilizing a novel mechanical chopper has been developed to measure the energy spectrum of neutral deuterium atoms emitted from a tokamak plasma. The chopper system consists of a motor, a magnetically levitated shaft, and a chopper disc. The 20 g disc is rigidly attached to a 159 g shaft assembly and the set is supported against gravity in vacuum by permanent magnets and a stabilizing servo system. All components are uhv compatible to avoid contamination to the tokamak and to the detector. The 25.4 cm OD, .005 cm thick, 301 stainless steel chopper disc has 24 .025more » cm wide slots photoetched at an 11.4 cm radius. An effective aperture time of .55 ..mu..s is achieved during typical steady state operation at 22,500 rpm with a vacuum pressure of 2 x 10/sup -8/ torr.« less

  13. Design of a -1 MV dc UHV power supply for ITER NBI

    NASA Astrophysics Data System (ADS)

    Watanabe, K.; Yamamoto, M.; Takemoto, J.; Yamashita, Y.; Dairaku, M.; Kashiwagi, M.; Taniguchi, M.; Tobari, H.; Umeda, N.; Sakamoto, K.; Inoue, T.

    2009-05-01

    Procurement of a dc -1 MV power supply system for the ITER neutral beam injector (NBI) is shared by Japan and the EU. The Japan Atomic Energy Agency as the Japan Domestic Agency (JADA) for ITER contributes to the procurement of dc -1 MV ultra-high voltage (UHV) components such as a dc -1 MV generator, a transmission line and a -1 MV insulating transformer for the ITER NBI power supply. The inverter frequency of 150 Hz in the -1 MV power supply and major circuit parameters have been proposed and adopted in the ITER NBI. The dc UHV insulation has been carefully designed since dc long pulse insulation is quite different from conventional ac insulation or dc short pulse systems. A multi-layer insulation structure of the transformer for a long pulse up to 3600 s has been designed with electric field simulation. Based on the simulation the overall dimensions of the dc UHV components have been finalized. A surge energy suppression system is also essential to protect the accelerator from electric breakdowns. The JADA contributes to provide an effective surge suppression system composed of core snubbers and resistors. Input energy into the accelerator from the power supply can be reduced to about 20 J, which satisfies the design criteria of 50 J in total in the case of breakdown at -1 MV.

  14. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Jungdae; Department of Physics and EHSRC, University of Ulsan, Ulsan 680-749; Nam, Hyoungdo

    2015-09-15

    We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper andmore » stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.« less

  15. An advanced molecule-surface scattering instrument for study of vibrational energy transfer in gas-solid collisions.

    PubMed

    Ran, Qin; Matsiev, Daniel; Wodtke, Alec M; Auerbach, Daniel J

    2007-10-01

    We describe an advanced and highly sensitive instrument for quantum state-resolved molecule-surface energy transfer studies under ultrahigh vacuum (UHV) conditions. The apparatus includes a beam source chamber, two differential pumping chambers, and a UHV chamber for surface preparation, surface characterization, and molecular beam scattering. Pulsed and collimated supersonic molecular beams are generated by expanding target molecule mixtures through a home-built pulsed nozzle, and excited quantum state-selected molecules were prepared via tunable, narrow-band laser overtone pumping. Detection systems have been designed to measure specific vibrational-rotational state, time-of-flight, angular and velocity distributions of molecular beams coming to and scattered off the surface. Facilities are provided to clean and characterize the surface under UHV conditions. Initial experiments on the scattering of HCl(v = 0) from Au(111) show many advantages of this new instrument for fundamental studies of the energy transfer at the gas-surface interface.

  16. Transmission Technologies and Operational Characteristic Analysis of Hybrid UHV AC/DC Power Grids in China

    NASA Astrophysics Data System (ADS)

    Tian, Zhang; Yanfeng, Gong

    2017-05-01

    In order to solve the contradiction between demand and distribution range of primary energy resource, Ultra High Voltage (UHV) power grids should be developed rapidly to meet development of energy bases and accessing of large-scale renewable energy. This paper reviewed the latest research processes of AC/DC transmission technologies, summarized the characteristics of AC/DC power grids, concluded that China’s power grids certainly enter a new period of large -scale hybrid UHV AC/DC power grids and characteristics of “strong DC and weak AC” becomes increasingly pro minent; possible problems in operation of AC/DC power grids was discussed, and interaction or effect between AC/DC power grids was made an intensive study of; according to above problems in operation of power grids, preliminary scheme is summarized as fo llows: strengthening backbone structures, enhancing AC/DC transmission technologies, promoting protection measures of clean energ y accessing grids, and taking actions to solve stability problems of voltage and frequency etc. It’s valuable for making hybrid UHV AC/DC power grids adapt to operating mode of large power grids, thus guaranteeing security and stability of power system.

  17. A UHV compatible source for a highly polarized thermal atomic beam of radioactive 8Li

    NASA Astrophysics Data System (ADS)

    Jänsch, H. J.; Kirchner, G.; Kühlert, O.; Lisowski, M.; Paggel, J. J.; Platzer, R.; Schillinger, R.; Tilsner, H.; Weindel, C.; Winnefeld, H.; Fick, D.

    2000-12-01

    A beam of the radioactive isotope 8Li is prepared at thermal velocities. The nuclei are highly spin polarized by transverse optical pumping of the thermal beam. The installation is ultra-high vacuum (UHV) compatible in a non-UHV accelerator environment. Since the atomic beam is used in a surface science experiment, where contamination must be avoided, special emphasis is given to the vacuum coupling of the accelerator/ 8Li production/surface experimental areas. The atomic beam is produced by stopping the nuclear reaction products and evaporating them again from high-temperature graphite. To enhance the atomic beam, a novel tubular thermalizer is applied. The thermal polarized atomic beam intensity is approximately 5×10 8 atoms/s sr.

  18. Surface development of a brazing alloy during heat treatment-a comparison between UHV and APXPS

    NASA Astrophysics Data System (ADS)

    Rullik, L.; Johansson, N.; Bertram, F.; Evertsson, J.; Stenqvist, T.; Lundgren, E.

    2018-01-01

    In an attempt to bridge the pressure gap, APXPS was used to follow the surface development of an aluminum brazing sheet during heating in an ambient oxygen-pressure mimicking the environment of an industrial brazing furnace. The studied aluminum alloy brazing sheet is a composite material consisting of two aluminum alloy standards whose surface is covered with a native aluminum oxide film. To emphasize the necessity of studies of this system in ambient sample environments it is compared to measurements in UHV. Changes in thickness and composition of the surface oxide were followed after heating to 300 °C, 400 °C, and 500 °C. The two sets presented in this paper show that the surface development strongly depends on the environment the sample is heated in.

  19. In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

    NASA Technical Reports Server (NTRS)

    Heinemann, K.; Poppa, H.

    1973-01-01

    A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

  20. Full membrane spanning self-assembled monolayers as model systems for UHV-based studies of cell-penetrating peptides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franz, Johannes; Graham, Daniel J.; Schmüser, Lars

    2015-03-01

    Biophysical studies of the interaction of peptides with model membranes provide a simple yet effective approach to understand the transport of peptides and peptide based drug carriers across the cell membrane. Therein, the authors discuss the use of self-assembled monolayers fabricated from the full membrane-spanning thiol (FMST) 3-((14-((4'-((5-methyl-1-phenyl-35-(phytanyl)oxy-6,9,12,15,18,21,24,27,30,33,37-undecaoxa-2,3-dithiahenpentacontan-51-yl)oxy)-[1,1'-biphenyl]-4-yl)oxy)tetradecyl)oxy)-2-(phytanyl)oxy glycerol for ultrahigh vacuum (UHV) based experiments. UHV-based methods such as electron spectroscopy and mass spectrometry can provide important information about how peptides bind and interact with membranes, especially with the hydrophobic core of a lipid bilayer. Moreover, near-edge x-ray absorption fine structure spectra and x-ray photoelectron spectroscopy (XPS) data showed thatmore » FMST forms UHV-stable and ordered films on gold. XPS and time of flight secondary ion mass spectrometry depth profiles indicated that a proline-rich amphipathic cell-penetrating peptide, known as sweet arrow peptide is located at the outer perimeter of the model membrane.« less

  1. Atmospheric pressure reaction cell for operando sum frequency generation spectroscopy of ultrahigh vacuum grown model catalysts

    NASA Astrophysics Data System (ADS)

    Roiaz, Matteo; Pramhaas, Verena; Li, Xia; Rameshan, Christoph; Rupprechter, Günther

    2018-04-01

    A new custom-designed ultrahigh vacuum (UHV) chamber coupled to a UHV and atmospheric-pressure-compatible spectroscopic and catalytic reaction cell is described, which allows us to perform IR-vis sum frequency generation (SFG) vibrational spectroscopy during catalytic (kinetic) measurements. SFG spectroscopy is an exceptional tool to study vibrational properties of surface adsorbates under operando conditions, close to those of technical catalysis. This versatile setup allows performing surface science, SFG spectroscopy, catalysis, and electrochemical investigations on model systems, including single crystals, thin films, and deposited metal nanoparticles, under well-controlled conditions of gas composition, pressure, temperature, and potential. The UHV chamber enables us to prepare the model catalysts and to analyze their surface structure and composition by low energy electron diffraction and Auger electron spectroscopy, respectively. Thereafter, a sample transfer mechanism moves samples under UHV to the spectroscopic cell, avoiding air exposure. In the catalytic cell, SFG spectroscopy and catalytic tests (reactant/product analysis by mass spectrometry or gas chromatography) are performed simultaneously. A dedicated sample manipulation stage allows the model catalysts to be examined from LN2 temperature to 1273 K, with gaseous reactants in a pressure range from UHV to atmospheric. For post-reaction analysis, the SFG cell is rapidly evacuated and samples are transferred back to the UHV chamber. The capabilities of this new setup are demonstrated by benchmark results of CO adsorption on Pt and Pd(111) single crystal surfaces and of CO adsorption and oxidation on a ZrO2 supported Pt nanoparticle model catalyst grown by atomic layer deposition.

  2. An Einzel lens apparatus for deposition of levitated graphene on a substrate in UHV

    NASA Astrophysics Data System (ADS)

    Coppock, Joyce; Nagornykh, Pavel; McAdams, Ian; Kane, Bruce

    The goal of our research is to levitate a charged micron-scale graphene flake in an electrical AC quadrupole trap in ultra-high vacuum (UHV) in order to study its properties and dynamics while decoupled from any substrate. As a complement to the optical measurements that can be performed on the levitated flake, we are developing a method of depositing the same flake on a substrate, which can be removed from the system for further study using such probes as atomic force microscopy (AFM) and scanning tunneling microscopy (STM). As the flake is released from the trap and propelled toward the substrate, its trajectory will be controlled by an Einzel (electrostatic) lens to achieve accurate positioning on the substrate. This talk will discuss the design of the lens as well as particle tracing simulations to determine the proper lens voltage to focus the particle's trajectory. In the future, deposited graphene may be used to passivate H-terminated silicon. The method is expected to be generalizable to achieve deposition of 2D materials on surfaces in a clean UHV environment.

  3. Oxygen accumulation on metal surfaces investigated by XPS, AES and LEIS, an issue for sputter depth profiling under UHV conditions

    NASA Astrophysics Data System (ADS)

    Steinberger, R.; Celedón, C. E.; Bruckner, B.; Roth, D.; Duchoslav, J.; Arndt, M.; Kürnsteiner, P.; Steck, T.; Faderl, J.; Riener, C. K.; Angeli, G.; Bauer, P.; Stifter, D.

    2017-07-01

    Depth profiling using surface sensitive analysis methods in combination with sputter ion etching is a common procedure for thorough material investigations, where clean surfaces free of any contamination are essential. Hence, surface analytic studies are mostly performed under ultra-high vacuum (UHV) conditions, but the cleanness of such UHV environments is usually overrated. Consequently, the current study highlights the in principle known impact of the residual gas on metal surfaces (Fe, Mg, Al, Cr and Zn) for various surface analytics methods, like X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES) and low-energy ion scattering (LEIS). The investigations with modern, state-of-the-art equipment showed different behaviors for the metal surfaces in UHV during acquisition: (i) no impact for Zn, even after long time, (ii) solely adsorption of oxygen for Fe, slight and slow changes for Cr and (iii) adsorption accompanied by oxide formation for Al and Mg. The efficiency of different counter measures was tested and the acquired knowledge was finally used for ZnMgAl coated steel to obtain accurate depth profiles, which exhibited before serious artifacts when data acquisition was performed in an inconsiderate way.

  4. Highly hydrogen-sensitive thermal desorption spectroscopy system for quantitative analysis of low hydrogen concentration (˜1 × 1016 atoms/cm3) in thin-film samples

    NASA Astrophysics Data System (ADS)

    Hanna, Taku; Hiramatsu, Hidenori; Sakaguchi, Isao; Hosono, Hideo

    2017-05-01

    We developed a highly hydrogen-sensitive thermal desorption spectroscopy (HHS-TDS) system to detect and quantitatively analyze low hydrogen concentrations in thin films. The system was connected to an in situ sample-transfer chamber system, manipulators, and an rf magnetron sputtering thin-film deposition chamber under an ultra-high-vacuum (UHV) atmosphere of ˜10-8 Pa. The following key requirements were proposed in developing the HHS-TDS: (i) a low hydrogen residual partial pressure, (ii) a low hydrogen exhaust velocity, and (iii) minimization of hydrogen thermal desorption except from the bulk region of the thin films. To satisfy these requirements, appropriate materials and components were selected, and the system was constructed to extract the maximum performance from each component. Consequently, ˜2000 times higher sensitivity to hydrogen than that of a commercially available UHV-TDS system was achieved using H+-implanted Si samples. Quantitative analysis of an amorphous oxide semiconductor InGaZnO4 thin film (1 cm × 1 cm × 1 μm thickness, hydrogen concentration of 4.5 × 1017 atoms/cm3) was demonstrated using the HHS-TDS system. This concentration level cannot be detected using UHV-TDS or secondary ion mass spectroscopy (SIMS) systems. The hydrogen detection limit of the HHS-TDS system was estimated to be ˜1 × 1016 atoms/cm3, which implies ˜2 orders of magnitude higher sensitivity than that of SIMS and resonance nuclear reaction systems (˜1018 atoms/cm3).

  5. Gas chromatograph sample-transfer valve

    NASA Technical Reports Server (NTRS)

    Wang, W. S.; Wright, H. W., Jr.

    1971-01-01

    Slide-type gate valve incorporates sampling volume and transfer passageway for guiding a metered quantity of gas from pressurized test cell to gas chromatograph. Gate is moved by pneumatic bellows-type actuator.

  6. Harmonic voltage excess problem test and analysis in UHV and EHV grid particular operation mode

    NASA Astrophysics Data System (ADS)

    Lv, Zhenhua; Shi, Mingming; Fei, Juntao

    2018-02-01

    The test and analysis of the power quality of some 1000kV UHV transmission lines and 500kV EHV transmission lines is carried out. It is found that there is harmonic voltage excess problems when the power supply of the UHV and EHV voltage line is single-ended or single-loop, the problem basically disappeared after the operation mode change, different operating conditions, the harmonic current has not been greatly affected, indicating that the harmonic voltage changes mainly caused by the system harmonic impedance. With the analysis of MATLAB Simulink system model, it can be seen that there are specific harmonic voltage excess in the system under the specific operating mode, which results in serious distortion of the specific harmonic voltage. Since such phenomena are found in 500kV and 1000kV systems, it is suggested that the test evaluation work should be done under the typical mode of operation in 500kV, 1000kV Planning and construction process to prevent the occurrence of serious distortion and the regional harmonic current monitoring and suppression work should be done.

  7. Subsurface Sample Acquisition and Transfer Systems (SSATS)

    NASA Astrophysics Data System (ADS)

    Rafeek, S.; Gorevan, S. P.; Kong, K. Y.

    2001-01-01

    In the exploration of planets and small bodies, scientists will need the services of a deep drilling and material handling system to not only obtain the samples necessary for analyses but also to precisely transfer and deposit those samples in in-situ instruments on board a landed craft or rover. The technology for such a deep sampling system as the SSATS is currently been developed by Honeybee Robotics through a PIDDP effort. The SSATS has its foundation in a one-meter prototype (SATM) drill that was developed under the New Millenium Program for ST4/Champollion. Additionally the SSATS includes relevant coring technology form a coring drill (Athena Mini-Corer) developed for the Mars Sample Return Mission. These highly developed technologies along with the current PIDDP effort, is combined to produce a sampling system that can acquire and transfer samples from various depths. Additional information is contained in the original extended abstract.

  8. Plasma diagnostic development and UHV testing for the ALPHA collaboration at Marquette University

    NASA Astrophysics Data System (ADS)

    Tharp, T. D.; Alpha Collaboration

    2017-10-01

    At Marquette, we are developing the next generation of nonneutral plasma diagnostics for the ALPHA experiment at CERN. ALPHA is building a new vertical experiment to test the gravitational interaction of antihydrogen with Earth. This expansion requires significant changes to the design of our plasma diagnostic suites: the next generation of tools must be able to measure plasmas from two directions, and must be capable of operating in a horizontal position. The diagnostic suite includes measurements of plasma density, shape, and temperature. The hardware used includes a MicroChannel Plate (MCP), a Faraday Cup, and an electron gun. In addition, we are building a vacuum chamber to test the viability of 3-d printed components for UHV compatibility, with target pressures of 10-10 mbar.

  9. Note: A simple sample transfer alignment for ultra-high vacuum systems.

    PubMed

    Tamtögl, A; Carter, E A; Ward, D J; Avidor, N; Kole, P R; Jardine, A P; Allison, W

    2016-06-01

    The alignment of ultra-high-vacuum sample transfer systems can be problematic when there is no direct line of sight to assist the user. We present the design of a simple and cheap system which greatly simplifies the alignment of sample transfer devices. Our method is based on the adaptation of a commercial digital camera which provides live views from within the vacuum chamber. The images of the camera are further processed using an image recognition and processing code which determines any misalignments and reports them to the user. Installation has proven to be extremely useful in order to align the sample with respect to the transfer mechanism. Furthermore, the alignment software can be easily adapted for other systems.

  10. An ultra-high vacuum scanning tunneling microscope operating at sub-Kelvin temperatures and high magnetic fields for spin-resolved measurements

    NASA Astrophysics Data System (ADS)

    Salazar, C.; Baumann, D.; Hänke, T.; Scheffler, M.; Kühne, T.; Kaiser, M.; Voigtländer, R.; Lindackers, D.; Büchner, B.; Hess, C.

    2018-06-01

    We present the construction and performance of an ultra-low-temperature scanning tunneling microscope (STM), working in ultra-high vacuum (UHV) conditions and in high magnetic fields up to 9 T. The cryogenic environment of the STM is generated by a single-shot 3He magnet cryostat in combination with a 4He dewar system. At a base temperature (300 mK), the cryostat has an operation time of approximately 80 h. The special design of the microscope allows the transfer of the STM head from the cryostat to a UHV chamber system, where samples and STM tips can be easily exchanged. The UHV chambers are equipped with specific surface science treatment tools for the functionalization of samples and tips, including high-temperature treatments and thin film deposition. This, in particular, enables spin-resolved tunneling measurements. We present test measurements using well-known samples and tips based on superconductors and metallic materials such as LiFeAs, Nb, Fe, and W. The measurements demonstrate the outstanding performance of the STM with high spatial and energy resolution as well as the spin-resolved capability.

  11. Efficient global biopolymer sampling with end-transfer configurational bias Monte Carlo

    NASA Astrophysics Data System (ADS)

    Arya, Gaurav; Schlick, Tamar

    2007-01-01

    We develop an "end-transfer configurational bias Monte Carlo" method for efficient thermodynamic sampling of complex biopolymers and assess its performance on a mesoscale model of chromatin (oligonucleosome) at different salt conditions compared to other Monte Carlo moves. Our method extends traditional configurational bias by deleting a repeating motif (monomer) from one end of the biopolymer and regrowing it at the opposite end using the standard Rosenbluth scheme. The method's sampling efficiency compared to local moves, pivot rotations, and standard configurational bias is assessed by parameters relating to translational, rotational, and internal degrees of freedom of the oligonucleosome. Our results show that the end-transfer method is superior in sampling every degree of freedom of the oligonucleosomes over other methods at high salt concentrations (weak electrostatics) but worse than the pivot rotations in terms of sampling internal and rotational sampling at low-to-moderate salt concentrations (strong electrostatics). Under all conditions investigated, however, the end-transfer method is several orders of magnitude more efficient than the standard configurational bias approach. This is because the characteristic sampling time of the innermost oligonucleosome motif scales quadratically with the length of the oligonucleosomes for the end-transfer method while it scales exponentially for the traditional configurational-bias method. Thus, the method we propose can significantly improve performance for global biomolecular applications, especially in condensed systems with weak nonbonded interactions and may be combined with local enhancements to improve local sampling.

  12. Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples

    NASA Astrophysics Data System (ADS)

    Fujishiro, F.; Ishii, K.; Matsuyama, S.; Arai, H.; Ishizaki, A.; Osada, N.; Sugai, H.; Kusano, K.; Nozawa, Y.; Yamauchi, S.; Karahashi, M.; Oshikawa, S.; Kikuchi, K.; Koshio, S.; Watanabe, K.; Suzuki, Y.

    2014-01-01

    Micro-PIXE analysis has been performed on two soil samples with high cesium activity concentrations. These soil samples were contaminated by fallout from the accident at Fukushima Daiichi Nuclear Power Plant. One exhibits a radioactive cesium transfer of ˜0.01, and the other shows a radioactive cesium transfer of less than 0.001, even though both samples have high cesium activity concentrations exceeding 10,000 Bq/kg. X-ray spectra and elemental images of the soil samples revealed the presence of chlorine, which can react with cesium to produce an inorganic soluble compound, and phosphorus-containing cesium-capturable organic compounds.

  13. Umbrella sampling of proton transfer in a creatine-water system

    NASA Astrophysics Data System (ADS)

    Ivchenko, Olga; Bachert, Peter; Imhof, Petra

    2014-04-01

    Proton transfer reactions are among the most common processes in chemistry and biology. Proton transfer between creatine and surrounding solvent water is underlying the chemical exchange saturation transfer used as a contrast in magnetic resonance imaging. The free energy barrier, determined by first-principles umbrella sampling simulations (EaDFT 3 kcal/mol) is in the same order of magnitude as the experimentally obtained activation energy. The underlying mechanism is a first proton transfer from the guanidinium group to the water pool, followed by a second transition where a proton is "transferred back" from the nearest water molecule to the deprotonated nitrogen atom of creatine.

  14. Small-volume, ultrahigh-vacuum-compatible high-pressure reaction cell for combined kinetic and in situ IR spectroscopic measurements on planar model catalysts

    NASA Astrophysics Data System (ADS)

    Zhao, Z.; Diemant, T.; Häring, T.; Rauscher, H.; Behm, R. J.

    2005-12-01

    We describe the design and performance of a high-pressure reaction cell for simultaneous kinetic and in situ infrared reflection (IR) spectroscopic measurements on model catalysts at elevated pressures, between 10-3 and 103mbars, which can be operated both as batch reactor and as flow reactor with defined gas flow. The cell is attached to an ultrahigh-vacuum (UHV) system, which is used for sample preparation and also contains facilities for sample characterization. Specific for this design is the combination of a small cell volume, which allows kinetic measurements with high sensitivity under batch or continuous flow conditions, the complete isolation of the cell from the UHV part during UHV measurements, continuous temperature control during both UHV and high-pressure operation, and rapid transfer between UHV and high-pressure stage. Gas dosing is performed by a designed gas-handling system, which allows operation as flow reactor with calibrated gas flows at adjustable pressures. To study the kinetics of reactions on the model catalysts, a quadrupole mass spectrometer is connected to the high-pressure cell. IR measurements are possible in situ by polarization-modulation infrared reflection-absorption spectroscopy, which also allows measurements at elevated pressures. The performance of the setup is demonstrated by test measurements on the kinetics for CO oxidation and the CO adsorption on a Au /TiO2/Ru(0001) model catalyst film at 1-50 mbar total pressure.

  15. Situ soil sampling probe system with heated transfer line

    DOEpatents

    Robbat, Jr., Albert

    2002-01-01

    The present invention is directed both to an improved in situ penetrometer probe and to a heated, flexible transfer line. The line and probe may be implemented together in a penetrometer system in which the transfer line is used to connect the probe to a collector/analyzer at the surface. The probe comprises a heater that controls a temperature of a geologic medium surrounding the probe. At least one carrier gas port and vapor collection port are located on an external side wall of the probe. The carrier gas port provides a carrier gas into the geologic medium, and the collection port captures vapors from the geologic medium for analysis. In the transfer line, a flexible collection line that conveys a collected fluid, i.e., vapor, sample to a collector/analyzer. A flexible carrier gas line conveys a carrier gas to facilitate the collection of the sample. A system heating the collection line is also provided. Preferably the collection line is electrically conductive so that an electrical power source can generate a current through it so that the internal resistance generates heat.

  16. Modulation transfer function cascade model for a sampled IR imaging system.

    PubMed

    de Luca, L; Cardone, G

    1991-05-01

    The performance of the infrared scanning radiometer (IRSR) is strongly stressed in convective heat transfer applications where high spatial frequencies in the signal that describes the thermal image are present. The need to characterize more deeply the system spatial resolution has led to the formulation of a cascade model for the evaluation of the actual modulation transfer function of a sampled IR imaging system. The model can yield both the aliasing band and the averaged modulation response for a general sampling subsystem. For a line scan imaging system, which is the case of a typical IRSR, a rule of thumb that states whether the combined sampling-imaging system is either imaging-dependent or sampling-dependent is proposed. The model is tested by comparing it with other noncascade models as well as by ad hoc measurements performed on a commercial digitized IRSR.

  17. UHV-TEM/TED observation of Ag islands grown on Si( 1 1 1 ) 3× 3-Ag surface

    NASA Astrophysics Data System (ADS)

    Oshima, Yoshifumi; Nakade, Hiroyuki; Shigeki, Sinya; Hirayama, Hiroyuki; Takayanagi, Kunio

    2001-11-01

    Growths of Ag islands on Si(1 1 1)3×3-Ag surface at room temperature were observed by UHV transmission electron microscopy and diffraction. The Ag islands grown after six monolayer deposition had neither (1 0 0) nor (1 1 0) orientation, but had two complex epitaxial orientations dominantly. One was striped islands which gave rise to a diffraction pattern commensurate with the 3×3 lattice of the Si(1 1 1) surface. The other was the coagulated islands whose diffraction pattern indicated the Ag(1 -3 4) sheet grown parallel to the Si(1 1 1) surface.

  18. Custom sample environments at the ALBA XPEEM.

    PubMed

    Foerster, Michael; Prat, Jordi; Massana, Valenti; Gonzalez, Nahikari; Fontsere, Abel; Molas, Bernat; Matilla, Oscar; Pellegrin, Eric; Aballe, Lucia

    2016-12-01

    A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500MHz storage ring RF frequency. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Versatile, low-cost, computer-controlled, sample positioning system for vacuum applications

    NASA Technical Reports Server (NTRS)

    Vargas-Aburto, Carlos; Liff, Dale R.

    1991-01-01

    A versatile, low-cost, easy to implement, microprocessor-based motorized positioning system (MPS) suitable for accurate sample manipulation in a Second Ion Mass Spectrometry (SIMS) system, and for other ultra-high vacuum (UHV) applications was designed and built at NASA LeRC. The system can be operated manually or under computer control. In the latter case, local, as well as remote operation is possible via the IEEE-488 bus. The position of the sample can be controlled in three linear orthogonal and one angular coordinates.

  20. System to measure accurate temperature dependence of electric conductivity down to 20 K in ultrahigh vacuum.

    PubMed

    Sakai, C; Takeda, S N; Daimon, H

    2013-07-01

    We have developed the new in situ electrical-conductivity measurement system which can be operated in ultrahigh vacuum (UHV) with accurate temperature measurement down to 20 K. This system is mainly composed of a new sample-holder fixing mechanism, a new movable conductivity-measurement mechanism, a cryostat, and two receptors for sample- and four-probe holders. Sample-holder is pushed strongly against the receptor, which is connected to a cryostat, by using this new sample-holder fixing mechanism to obtain high thermal conductivity. Test pieces on the sample-holders have been cooled down to about 20 K using this fixing mechanism, although they were cooled down to only about 60 K without this mechanism. Four probes are able to be touched to a sample surface using this new movable conductivity-measurement mechanism for measuring electrical conductivity after making film on substrates or obtaining clean surfaces by cleavage, flashing, and so on. Accurate temperature measurement is possible since the sample can be transferred with a thermocouple and∕or diode being attached directly to the sample. A single crystal of Bi-based copper oxide high-Tc superconductor (HTSC) was cleaved in UHV to obtain clean surface, and its superconducting critical temperature has been successfully measured in situ. The importance of in situ measurement of resistance in UHV was demonstrated for this HTSC before and after cesium (Cs) adsorption on its surface. The Tc onset increase and the Tc offset decrease by Cs adsorption were observed.

  1. Performance analysis of microcomputer based differential protection of UHV lines under selective phase switching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatti, A.A.

    1990-04-01

    This paper examines the effects of primary and secondary fault quantities as well s of mutual couplings of neighboring circuits on the sensitivity of operation and threshold settings of a microcomputer based differential protection of UHV lines under selective phase switching. Microcomputer based selective phase switching allows the disconnection of minimum number of phases involved in a fault and requires the autoreclosing of these phases immediately after the extinction of secondary arc. During a primary fault a heavy current contribution to the healthy phases tends to cause an unwanted tripping. Faulty phases physically disconnected constitute an isolated fault which beingmore » coupled to the system affects the current and voltage levels of the healthy phases still retained in the system and may cause an unwanted tripping. The microcomputer based differential protection, appears to have poor performance when applied to uncompensated lines employing selective pole switching.« less

  2. Miniaturized material sampling and transfer devices for extraterrestrial exploration

    NASA Astrophysics Data System (ADS)

    Gorevan, S.; Rafeek, S.; Myrick, T.; Kong, K. Y.; Mahaffey, P.

    1997-01-01

    For early extraterrestrial exploration with a limited payload, miniaturized sampling devices that can be mounted on a rover platform will be crucial in locating areas with high resource concentration for future extraction, storage and utilization. Two such rover friendly sampling devices are the gas Sniffer and the Sample Acquisition and Transfer Mechanism (SATM). The Sniffer is a miniaturized gas sampler that can be utilized for the characterization of atmospheric, surface and subsurface molecular composition as a function of time and site location. The device is embodied in the tip of a non-rotating, drill sleeve just behind the auger and cutting head. SATM is another highly developed miniature sampling device that can repeatedly deliver solid samples (acquired from the surface to depths of 1 meter below surface) to a number of on-board instruments such as microscopes (for cataloging), ovens (for composition analyses) and/or to a hermetically sealed sample return canister for a sample return mission.

  3. Linear model correction: A method for transferring a near-infrared multivariate calibration model without standard samples.

    PubMed

    Liu, Yan; Cai, Wensheng; Shao, Xueguang

    2016-12-05

    Calibration transfer is essential for practical applications of near infrared (NIR) spectroscopy because the measurements of the spectra may be performed on different instruments and the difference between the instruments must be corrected. For most of calibration transfer methods, standard samples are necessary to construct the transfer model using the spectra of the samples measured on two instruments, named as master and slave instrument, respectively. In this work, a method named as linear model correction (LMC) is proposed for calibration transfer without standard samples. The method is based on the fact that, for the samples with similar physical and chemical properties, the spectra measured on different instruments are linearly correlated. The fact makes the coefficients of the linear models constructed by the spectra measured on different instruments are similar in profile. Therefore, by using the constrained optimization method, the coefficients of the master model can be transferred into that of the slave model with a few spectra measured on slave instrument. Two NIR datasets of corn and plant leaf samples measured with different instruments are used to test the performance of the method. The results show that, for both the datasets, the spectra can be correctly predicted using the transferred partial least squares (PLS) models. Because standard samples are not necessary in the method, it may be more useful in practical uses. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Organic cleanliness of the Mars Science Laboratory sample transfer chain.

    PubMed

    Blakkolb, B; Logan, C; Jandura, L; Okon, A; Anderson, M; Katz, I; Aveni, G; Brown, K; Chung, S; Ferraro, N; Limonadi, D; Melko, J; Mennella, J; Yavrouian, A

    2014-07-01

    One of the primary science goals of the Mars Science Laboratory (MSL) Rover, Curiosity, is the detection of organics in Mars rock and regolith. To achieve this, the Curiosity rover includes a robotic sampling system that acquires rock and regolith samples and delivers it to the Sample Analysis at Mars (SAM) instrument on board the rover. In order to provide confidence that any significant organics detection result was Martian and not terrestrial in origin, a requirement was levied on the flight system (i.e., all sources minus the SAM instrument) to impart no more than 36 parts per billion (ppb by weight) of total reduced carbon terrestrial contamination to any sample transferred to the SAM instrument. This very clean level was achieved by a combination of a rigorous contamination control program on the project, and then using the first collected samples for a "dilution cleaning" campaign of the sample chain prior to delivering a sample to the SAM instrument. Direct cleanliness assays of the sample-contacting and other Flight System surfaces during pre-launch processing were used as inputs to determine the number of dilution cleaning samples needed once on Mars, to enable delivery of suitably clean samples to the SAM experiment. Taking into account contaminant redistribution during launch thorough landing of the MSL on Mars, the amount of residue present on the sampling hardware prior to the time of first dilution cleaning sample acquisition was estimated to be 60 ng/cm(2) on exposed outer surfaces of the sampling hardware and 20 ng/cm(2) on internal sample contacting surfaces; residues consisting mainly of aliphatic hydrocarbons and esters. After three dilution cleaning samples, estimated in-sample contamination level for the first regolith sample delivered to the SAM instrument at the Gale Crater "Rocknest" site was bounded at ≤10 ppb total organic carbon. A Project decision to forego ejecting the dilution cleaning sample and instead transfer the first drill

  5. Design and qualification of an UHV system for operation on sounding rockets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grosse, Jens, E-mail: jens.grosse@dlr.de; Braxmaier, Claus; Seidel, Stephan Tobias

    The sounding rocket mission MAIUS-1 has the objective to create the first Bose–Einstein condensate in space; therefore, its scientific payload is a complete cold atom experiment built to be launched on a VSB-30 sounding rocket. An essential part of the setup is an ultrahigh vacuum system needed in order to sufficiently suppress interactions of the cooled atoms with the residual background gas. Contrary to vacuum systems on missions aboard satellites or the international space station, the required vacuum environment has to be reached within 47 s after motor burn-out. This paper contains a detailed description of the MAIUS-1 vacuum system, asmore » well as a description of its qualification process for the operation under vibrational loads of up to 8.1 g{sub RMS} (where RMS is root mean square). Even though a pressure rise dependent on the level of vibration was observed, the design presented herein is capable of regaining a pressure of below 5 × 10{sup −10} mbar in less than 40 s when tested at 5.4 g{sub RMS}. To the authors' best knowledge, it is the first UHV system qualified for operation on a sounding rocket.« less

  6. Extreme pressure fluid sample transfer pump

    DOEpatents

    Halverson, Justin E.; Bowman, Wilfred W.

    1990-01-01

    A transfer pump for samples of fluids at very low or very high pressures comprising a cylinder having a piston sealed with an O-ring, the piston defining forward and back chambers, an inlet and exit port and valve arrangement for the fluid to enter and leave the forward chamber, and a port and valve arrangement in the back chamber for adjusting the pressure across the piston so that the pressure differential across the piston is essentially zero and approximately equal to the pressure of the fluid so that the O-ring seals against leakage of the fluid and the piston can be easily moved, regardless of the pressure of the fluid. The piston may be actuated by a means external to the cylinder with a piston rod extending through a hole in the cylinder sealed with a bellows attached to the piston head and the interior of the back chamber.

  7. Study of the Decomposition and Phase Transition of Uranium Nitride under UHV Conditions via TDS, XRD, SEM, and XPS.

    PubMed

    Wang, Xiaofang; Long, Zhong; Bin, Ren; Yang, Ruilong; Pan, Qifa; Li, Fangfang; Luo, Lizhu; Hu, Yin; Liu, Kezhao

    2016-11-07

    Uranium nitrides are among the most promising fuels for Generation IV nuclear reactors, but until now, very little has been known about their thermal stability properties under nonequilibrium conditions. In this work, thermal decomposition of nitrogen-rich uranium nitride (denoted as UN 2-x ) under ultrahigh-vacuum (UHV) conditions was investigated by thermal desorption spectroscopy (TDS). It has been shown that the nitrogen TDS spectrum consists of two peaks at about 723 and 1038 K. The X-ray diffraction, scanning electron microscopy, and X-ray photoelectron microscopy results indicate that UN 2-x (UN 2 phase) decomposed into the α-U 2 N 3 phase in the first step and the α-U 2 N 3 phase decomposed into the UN phase in the second step.

  8. Influence of the surface chemistry on TiO2 - TiO2 nanocontact forces as measured by an UHV-AFM

    NASA Astrophysics Data System (ADS)

    Kunze, Christian; Giner, Ignacio; Torun, Boray; Grundmeier, Guido

    2014-03-01

    Particle-wall contact forces between a TiO2 film coated AFM tip and TiO2(1 1 0) single crystal surfaces were analyzed by means of UHV-AFM. As a reference system an octadecylphosphonic acid monolayer covered TiO2(1 1 0) surface was studied. The defect chemistry of the TiO2 substrate was modified by Ar ion bombardment, water dosing at 3 × 10-6 Pa and an annealing step at 473 K which resulted in a varying density of Ti(III) states. The observed contact forces are correlated to the surface defect density and are discussed in terms of the change in the electronic structure and its influence on the Hamaker constant.

  9. Path Sampling Methods for Enzymatic Quantum Particle Transfer Reactions

    PubMed Central

    Dzierlenga, M.W.; Varga, M.J.

    2016-01-01

    The mechanisms of enzymatic reactions are studied via a host of computational techniques. While previous methods have been used successfully, many fail to incorporate the full dynamical properties of enzymatic systems. This can lead to misleading results in cases where enzyme motion plays a significant role in the reaction coordinate, which is especially relevant in particle transfer reactions where nuclear tunneling may occur. In this chapter, we outline previous methods, as well as discuss newly developed dynamical methods to interrogate mechanisms of enzymatic particle transfer reactions. These new methods allow for the calculation of free energy barriers and kinetic isotope effects (KIEs) with the incorporation of quantum effects through centroid molecular dynamics (CMD) and the full complement of enzyme dynamics through transition path sampling (TPS). Recent work, summarized in this chapter, applied the method for calculation of free energy barriers to reaction in lactate dehydrogenase (LDH) and yeast alcohol dehydrogenase (YADH). It was found that tunneling plays an insignificant role in YADH but plays a more significant role in LDH, though not dominant over classical transfer. Additionally, we summarize the application of a TPS algorithm for the calculation of reaction rates in tandem with CMD to calculate the primary H/D KIE of YADH from first principles. It was found that the computationally obtained KIE is within the margin of error of experimentally determined KIEs, and corresponds to the KIE of particle transfer in the enzyme. These methods provide new ways to investigate enzyme mechanism with the inclusion of protein and quantum dynamics. PMID:27497161

  10. UHV AFM based colloidal probe studies of adhesive properties of VAlN hard coatings

    NASA Astrophysics Data System (ADS)

    Wiesing, M.; de los Arcos, T.; Grundmeier, G.

    2018-01-01

    The adhesion of polystyrene (PS) on V0.27Al0.29N0.44 and the related influence of the oxidation states of both surfaces was investigated using X-Ray Photoelectron Spectroscopy (XPS) and Colloidal Force Spectroscopy (CFS) in Ultra-High Vacuum (UHV). Complementary, the intimate relation between the adhesion force, the chemical structure and surface polarizability was investigated by XPS valence band spectroscopy and the calculation of non-retarded Hamaker coefficients using Lifshitz theory based on optical data as derived from Reflection Electron Energy Loss Spectroscopy (REELS) spectra. The combined electron and force spectroscopic analysis of the interaction forces disclosed quantitatively the separation of the adhesion force in van der Waals and Lewis acid-base contributions. Further, the surface polarizability of VAlN was shown to be unaffected by oxygen incorporation due to the formation of an only gradually oxidized surface comprising a range of vanadium oxidation states. In contrast, the adhesion force analysis revealed additional Lewis acid-base interactions between the oxidized and non-oxidized VAlN surfaces and carboxyl groups present in the surface of PS after an oxidative oxygen beam treatment.

  11. Operando Positron Annihilation Gamma Spectrometer (OPAGS)

    NASA Astrophysics Data System (ADS)

    Satyal, S.; Shastry, K.; Mukherjee, S.; Weiss, A. H.

    2009-03-01

    Surface properties measured under UHV conditions cannot be extended to surfaces interacting with gases under realistic pressures due to surface reconstruction and other strong perturbations of the surface. Surface probing techniques require UHV conditions to perform efficiently and avoid data loss due to scattering of outgoing particles. This poster describes the design of an Operando Positron Annihilation Gamma Spectrometer (OPAGS) currently under construction at the University of Texas at Arlington. The new system will be capable of obtaining surface and defect specific chemical and charge state information from surfaces under realistic pressures. Differential pumping will be used to maintain the sample in a gas environment while the rest of the beam is under UHV. Elemental content of the surface interacting with the gas environment will be determined from the Doppler broadened gamma spectra. This system will also include a time of flight (TOF) Auger spectrometer which correlates with the results of the Doppler measurements at lower pressures. By employing the unique capabilities of OPAGS together with those of the TOF PAES spectroscopy the charge transfer mechanisms at the surface in catalytic systems can be understood.

  12. The Nickel(111)/Alkaline Electrolyte Interface

    NASA Technical Reports Server (NTRS)

    Wang, Kuilong; Chottiner, G. S.; Scherson, D. A.; Reid, Margaret A.

    1991-01-01

    The electrochemical properties of Ni (111) prepared and characterized in ultra high vacuum, UHV, by surface analytical techniques have been examined in alkaline media by cyclic voltammetry using an UHV-electrochemical cell transfer system designed and built in this laboratory. Prior to the transfer, the Ni(111) surfaces were exposed to saturation coverages of CO in UHV in an attempt to protect the surface from possible contamination with other gases during the transfer. Temperature Programmed Desorption, TPD, of CO-dosed Ni (111) surfaces displaying sharp c(4x2), LEED patterns, subsequently exposed to water-saturated Ar at atmospheric pressure in an auxiliary UHV compatible chamber and finally transferred back to the main UHV chamber, yielded CO2 and water as the only detectable products. This indicates that the CO-dosed surfaces react with water and/or bicarbonate and hydroxide as the most likely products. Based on the integration of the TPD peaks, the combined amounts of H2O and CO2 were found to be on the order of a single monolayer. The reacted c(4x2)CO/Ni(111) layer seems to protect the surface from undergoing spontaneous oxidation in strongly alkaline solutions. This was evidenced by the fact that the open circuit potential observed immediately after contact with deaerated 0.1 M KOH was about 0.38 V vs. DHE, drifting slightly towards more negative values prior to initiating the voltametric scans. The average ratio of the integrated charge obtained in the first positive linear scan in the range of 0.35 to 1.5 V vs. DHE (initiated at the open circuit potential) and the first (and subsequent) linear negative scans in the same solution yielded for various independent runs a value of 3.5 +/- 0.3. Coulometric analysis of the cyclic voltammetry curves indicate that the electrochemically formed oxyhydroxide layer involves a charge equivalent to 3.2 +/- 0.4 layers of Ni metal.

  13. Surface Structure of TiO2 Rutile (011) Exposed to Liquid Water

    PubMed Central

    2017-01-01

    The rutile TiO2(011) surface exhibits a (2 × 1) reconstruction when prepared by standard techniques in ultrahigh vacuum (UHV). Here we report that a restructuring occurs upon exposing the surface to liquid water at room temperature. The experiment was performed in a dedicated UHV system, equipped for direct and clean transfer of samples between UHV and liquid environment. After exposure to liquid water, an overlayer with a (2 × 1) symmetry was observed containing two dissociated water molecules per unit cell. The two OH groups yield an apparent “c(2 × 1)” symmetry in scanning tunneling microscopy (STM) images. On the basis of STM analysis and density functional theory (DFT) calculations, this overlayer is attributed to dissociated water on top of the unreconstructed (1 × 1) surface. Investigation of possible adsorption structures and analysis of the domain boundaries in this structure provide strong evidence that the original (2 × 1) reconstruction is lifted. Unlike the (2 × 1) reconstruction, the (1 × 1) surface has an appropriate density and symmetry of adsorption sites. The possibility of contaminant-induced restructuring was excluded based on X-ray photoelectron spectroscopy (XPS) and low-energy He+ ion scattering (LEIS) measurements. PMID:29285204

  14. Sonogashira cross-coupling over Au(1 1 1): from UHV to ambient pressure

    NASA Astrophysics Data System (ADS)

    Johansson, N.; Sisodiya, S.; Shayesteh, P.; Chaudhary, S.; Andersen, J. N.; Knudsen, J.; Wendt, O. F.; Schnadt, J.

    2017-11-01

    We have studied the reaction of phenylacetylene (PA) with chloro-, bromo-, and iodobenzene on the Au(1 1 1) surface as a model system for the gold-catalysed Sonogashira cross-coupling. Both ultrahigh vacuum-based and ambient pressure x-ray photoelectron spectroscopy show that iodo- and chlorobenzene (IB and CB) undergo the cross-coupling reaction towards diphenylacetylene. Bromobenzene (BB), in contrast, does not react in the UHV experiments. Further, at ambient pressure signs are found for poisoning of the Au(1 1 1) surface by a carbon species formed in the reaction. The understanding obtained in the reaction experiments are based on a thorough investigation of the adsorption of PA, IB, CB, and BB on the Au(1 1 1) surface by soft x-ray absorption spectroscopy and temperature-dependent x-ray photoelectron spectroscopy. In particular, the experiments provide the orientation of the intact adsorbates with respect to the surfaces at liquid nitrogen temperature. Dissociation in the temperature regime between  -80 and  -15 °C is observed for iodo- and chlorobenzene, but not for BB, in agreement with that only IB and CB, but not BB, react with PA to form diphenylacetylene. The difference is tentatively attributed to a difference in surface orientation of the different halobenzenes.

  15. Note: Low-temperature scanning tunneling microscope with detachable scanner and reliable transfer mechanism for tip and sample exchange

    NASA Astrophysics Data System (ADS)

    Ge, Weifeng; Wang, Jihao; Wang, Junting; Zhang, Jing; Hou, Yubin; Lu, Qingyou

    2017-12-01

    A homebuilt low-temperature scanning tunneling microscope (STM) featuring a detachable scanner based on a double slider design, along with a reliable transfer mechanism for tip and sample exchange, is present. The coarse motor is decoupled from the scanner, which prevents the motor instabilities including vibrations and drifts from entering the tip-sample loop and thus improves the performance of the STM. In addition, in situ exchange of tips and samples can be implemented easily and reliably using a winch-type transfer mechanism. Atomically resolved images on graphite are demonstrated to show the performance of the proposed STM.

  16. Note: Low-temperature scanning tunneling microscope with detachable scanner and reliable transfer mechanism for tip and sample exchange.

    PubMed

    Ge, Weifeng; Wang, Jihao; Wang, Junting; Zhang, Jing; Hou, Yubin; Lu, Qingyou

    2017-12-01

    A homebuilt low-temperature scanning tunneling microscope (STM) featuring a detachable scanner based on a double slider design, along with a reliable transfer mechanism for tip and sample exchange, is present. The coarse motor is decoupled from the scanner, which prevents the motor instabilities including vibrations and drifts from entering the tip-sample loop and thus improves the performance of the STM. In addition, in situ exchange of tips and samples can be implemented easily and reliably using a winch-type transfer mechanism. Atomically resolved images on graphite are demonstrated to show the performance of the proposed STM.

  17. Design of an Operando Positron Annihilation Gamma Spectrometer (OPAGS)

    NASA Astrophysics Data System (ADS)

    Satyal, S.; Joglekar, P.; Kalaskar, S.; Shastry, K.; Weiss, A. H.

    2010-03-01

    Surface properties measured under UHV conditions cannot be extended to surfaces interacting with gases under realistic pressures due to surface reconstruction and other strong perturbations of the surface. We present the design of an Operando Positron Annihilation Gamma Spectrometer (OPAGS) currently under construction at the University of Texas at Arlington. This new system will enable us to probe the surface and gather defect specific chemical and charge state information from surfaces under realistic pressures. Differential pumping will be used to maintain the sample in a gas environment while the rest of the beam is maintained under UHV. The Elemental content of the surface interacting with the gas environment will be determined from the Doppler broadened gamma spectra. This system will include a time of flight (TOF) positron annihilation induced Auger spectrometer (TOF-PAES) which correlates with the Doppler measurements at lower pressures. These new technique help to understand the charge transfer mechanisms at the surface.

  18. Revealed and stated preference valuation and transfer: A within-sample comparison of water quality improvement values

    NASA Astrophysics Data System (ADS)

    Ferrini, Silvia; Schaafsma, Marije; Bateman, Ian

    2014-06-01

    Benefit transfer (BT) methods are becoming increasingly important for environmental policy, but the empirical findings regarding transfer validity are mixed. A novel valuation survey was designed to obtain both stated preference (SP) and revealed preference (RP) data concerning river water quality values from a large sample of households. Both dichotomous choice and payment card contingent valuation (CV) and travel cost (TC) data were collected. Resulting valuations were directly compared and used for BT analyses using both unit value and function transfer approaches. WTP estimates are found to pass the convergence validity test. BT results show that the CV data produce lower transfer errors, below 20% for both unit value and function transfer, than TC data especially when using function transfer. Further, comparison of WTP estimates suggests that in all cases, differences between methods are larger than differences between study areas. Results show that when multiple studies are available, using welfare estimates from the same area but based on a different method consistently results in larger errors than transfers across space keeping the method constant.

  19. Movement of moisture in refrigerated cheese samples transferred to room temperature.

    PubMed

    Emmons, D B; Bradley, R L; Campbell, C; Sauvé, J P

    2001-01-01

    When cheese samples refrigerated at 4 degrees C in 120 mL plastic tubs were transferred to room temperature at 23 degrees C, moisture began to move from the warmer surface to the cooler interior; the difference after 1 h was 0.2-0.4%. Others had observed that moisture moved from the interior of warmer blocks of cheese to the cooler surface during cooling at the end of cheese manufacture. In loosely packed cheese prepared for analysis, part of the moisture movement may have been due to evaporation from the warmer surface and condensation on the cooler cheese. It is recommended that cheese be prepared for analysis immediately before weighing. Cheese samples that have been refrigerated, as in interlaboratory trials, should also be remixed or prepared again.

  20. Clinical Outcomes among Transferred Children with Ischemic and Hemorrhagic Strokes in the Nationwide Inpatient Sample.

    PubMed

    Adil, Malik M; Vidal, Gabriel A; Beslow, Lauren A

    2016-11-01

    Children with ischemic stroke (IS) and hemorrhagic stroke (HS) may require interfacility transfer for higher level of care. We compared the characteristics and clinical outcomes of transferred and nontransferred children with IS and HS. Children aged 1-18 years admitted to hospitals in the United States from 2008 to 2011 with a primary discharge diagnosis of IS and HS were identified from the National Inpatient Sample database by ICD-9 codes. Using logistic regression, we estimated the odds ratios (OR) and 95% confidence intervals (CI) for in-hospital mortality and discharge to nursing facilities (versus discharge home) between transferred and nontransferred patients. Of the 2815 children with IS, 26.7% were transferred. In-hospital mortality and discharge to nursing facilities were not different between transferred and nontransferred children in univariable analysis or in multivariable analysis that adjusted for age, sex, and confounding factors. Of the 6879 children with HS, 27.1% were transferred. Transferred compared to nontransferred children had higher rates of both in-hospital mortality (8% versus 4%, P = .003) and discharge to nursing facilities (25% versus 20%, P = .03). After adjusting for age, sex, and confounding factors, in-hospital mortality (OR 1.5, 95% CI 1.1-2.4, P = .04) remained higher in transferred children, whereas discharge to nursing facilities was not different between the groups. HS but not IS was associated with worse outcomes for children transferred to another hospital compared to children who were not transferred. Additional study is needed to understand what factors may contribute to poorer outcomes among transferred children with HS. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Transplacental transfer of polycyclic aromatic hydrocarbons in paired samples of maternal serum, umbilical cord serum, and placenta in Shanghai, China.

    PubMed

    Zhang, Xiaolan; Li, Xiaojing; Jing, Ye; Fang, Xiangming; Zhang, Xinyu; Lei, Bingli; Yu, Yingxin

    2017-03-01

    Prenatal exposure to polycyclic aromatic hydrocarbons (PAHs) is a high-priority public health concern. However, maternal to fetal transplacental transfer of PAHs has not been systematically studied. To investigate the transplacental transfer of PAHs from mother to fetus and determine the influence of lipophilicity (octanol-water partition coefficient, K OW ) on transfer process, in the present study, we measured the concentrations of 15 PAHs in 95 paired maternal and umbilical cord serum, and placenta samples (in total 285 samples) collected in Shanghai, China. The average concentration of total PAHs was the highest in maternal serums (1290 ng g -1 lipid), followed by umbilical cord serums (1150 ng g -1 lipid). The value was the lowest in placenta samples (673 ng g -1 lipid). Low molecular weight PAHs were the predominant compounds in the three matrices. Increases in fish and meat consumption did not lead to increases in maternal PAH levels, and no obvious gender differences in umbilical cord serums were observed. The widespread presence of PAHs in umbilical cord serums indicated the occurrence of transplacental transfer. The ratios of PAH concentrations in umbilical cord serum to those in maternal serum (F/M) and the concentrations in placenta to those in maternal serum (P/M) of paired samples were analyzed to characterize the transfer process of individual PAHs. Most F/M ratios on lipid basis were close to one (range: 0.79 to 1.36), which suggested that passive diffusion may control the transplacental transfer of PAHs from maternal serum to the fetal circulation. The P/M and F/M values calculated on lipid basis showed that PAHs with lower K OW were more likely to transfer from mother to fetus via the placenta. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A Sample Handling System for Mars Sample Return - Design and Status

    NASA Astrophysics Data System (ADS)

    Allouis, E.; Renouf, I.; Deridder, M.; Vrancken, D.; Gelmi, R.; Re, E.

    2009-04-01

    A mission to return atmosphere and soil samples form the Mars is highly desired by planetary scientists from around the world and space agencies are starting preparation for the launch of a sample return mission in the 2020 timeframe. Such a mission would return approximately 500 grams of atmosphere, rock and soil samples to Earth by 2025. Development of a wide range of new technology will be critical to the successful implementation of such a challenging mission. Technical developments required to realise the mission include guided atmospheric entry, soft landing, sample handling robotics, biological sealing, Mars atmospheric ascent sample rendezvous & capture and Earth return. The European Space Agency has been performing system definition studies along with numerous technology development studies under the framework of the Aurora programme. Within the scope of these activities Astrium has been responsible for defining an overall sample handling architecture in collaboration with European partners (sample acquisition and sample capture, Galileo Avionica; sample containment and automated bio-sealing, Verhaert). Our work has focused on the definition and development of the robotic systems required to move the sample through the transfer chain. This paper presents the Astrium team's high level design for the surface transfer system and the orbiter transfer system. The surface transfer system is envisaged to use two robotic arms of different sizes to allow flexible operations and to enable sample transfer over relatively large distances (~2 to 3 metres): The first to deploy/retract the Drill Assembly used for sample collection, the second for the transfer of the Sample Container (the vessel containing all the collected samples) from the Drill Assembly to the Mars Ascent Vehicle (MAV). The sample transfer actuator also features a complex end-effector for handling the Sample Container. The orbiter transfer system will transfer the Sample Container from the capture

  3. Another Look at the Mechanisms of Hydride Transfer Enzymes with Quantum and Classical Transition Path Sampling.

    PubMed

    Dzierlenga, Michael W; Antoniou, Dimitri; Schwartz, Steven D

    2015-04-02

    The mechanisms involved in enzymatic hydride transfer have been studied for years, but questions remain due, in part, to the difficulty of probing the effects of protein motion and hydrogen tunneling. In this study, we use transition path sampling (TPS) with normal mode centroid molecular dynamics (CMD) to calculate the barrier to hydride transfer in yeast alcohol dehydrogenase (YADH) and human heart lactate dehydrogenase (LDH). Calculation of the work applied to the hydride allowed for observation of the change in barrier height upon inclusion of quantum dynamics. Similar calculations were performed using deuterium as the transferring particle in order to approximate kinetic isotope effects (KIEs). The change in barrier height in YADH is indicative of a zero-point energy (ZPE) contribution and is evidence that catalysis occurs via a protein compression that mediates a near-barrierless hydride transfer. Calculation of the KIE using the difference in barrier height between the hydride and deuteride agreed well with experimental results.

  4. Stimulated Electron Desorption Studies from Microwave Vacuum Electronics / High Power Microwave Materials

    DTIC Science & Technology

    2010-02-11

    purchase a new gun. Mr. Mike Ackeret ( Transfer Engineering Inc.) Transfer Engineering’s expertise in specialty UHV work and machining propelled...modifications they helped design for the test stand. With UNLV guidance, Transfer Engineering designed and built the original UNLV SEE Test Stand...Staib electron gun, an isolated beam drift tube, a hexanode delay line with a chevron microchannel plate (MCP) stack, an isolated grid, an isolated

  5. Background sampling and transferability of species distribution model ensembles under climate change

    NASA Astrophysics Data System (ADS)

    Iturbide, Maialen; Bedia, Joaquín; Gutiérrez, José Manuel

    2018-07-01

    Species Distribution Models (SDMs) constitute an important tool to assist decision-making in environmental conservation and planning. A popular application of these models is the projection of species distributions under climate change conditions. Yet there are still a range of methodological SDM factors which limit the transferability of these models, contributing significantly to the overall uncertainty of the resulting projections. An important source of uncertainty often neglected in climate change studies comes from the use of background data (a.k.a. pseudo-absences) for model calibration. Here, we study the sensitivity to pseudo-absence sampling as a determinant factor for SDM stability and transferability under climate change conditions, focusing on European wide projections of Quercus robur as an illustrative case study. We explore the uncertainty in future projections derived from ten pseudo-absence realizations and three popular SDMs (GLM, Random Forest and MARS). The contribution of the pseudo-absence realization to the uncertainty was higher in peripheral regions and clearly differed among the tested SDMs in the whole study domain, being MARS the most sensitive - with projections differing up to a 40% for different realizations - and GLM the most stable. As a result we conclude that parsimonious SDMs are preferable in this context, avoiding complex methods (such as MARS) which may exhibit poor model transferability. Accounting for this new source of SDM-dependent uncertainty is crucial when forming multi-model ensembles to undertake climate change projections.

  6. 16 CFR Appendix C to Part 436 - Sample Item 20(2) Table-Transfers of Franchised Outlets

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(2) Table-Transfers of Franchised Outlets C Appendix C to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. C Appendix C to Part...

  7. 16 CFR Appendix C to Part 436 - Sample Item 20(2) Table-Transfers of Franchised Outlets

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Sample Item 20(2) Table-Transfers of Franchised Outlets C Appendix C to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. C Appendix C to Part...

  8. 16 CFR Appendix C to Part 436 - Sample Item 20(2) Table-Transfers of Franchised Outlets

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Sample Item 20(2) Table-Transfers of Franchised Outlets C Appendix C to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. C Appendix C to Part...

  9. 16 CFR Appendix C to Part 436 - Sample Item 20(2) Table-Transfers of Franchised Outlets

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Sample Item 20(2) Table-Transfers of Franchised Outlets C Appendix C to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. C Appendix C to Part...

  10. An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

    NASA Technical Reports Server (NTRS)

    Heinemann, K.; Poppa, H.

    1986-01-01

    A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

  11. Coring Sample Acquisition Tool

    NASA Technical Reports Server (NTRS)

    Haddad, Nicolas E.; Murray, Saben D.; Walkemeyer, Phillip E.; Badescu, Mircea; Sherrit, Stewart; Bao, Xiaoqi; Kriechbaum, Kristopher L.; Richardson, Megan; Klein, Kerry J.

    2012-01-01

    A sample acquisition tool (SAT) has been developed that can be used autonomously to sample drill and capture rock cores. The tool is designed to accommodate core transfer using a sample tube to the IMSAH (integrated Mars sample acquisition and handling) SHEC (sample handling, encapsulation, and containerization) without ever touching the pristine core sample in the transfer process.

  12. Free-energy analyses of a proton transfer reaction by simulated-tempering umbrella sampling and first-principles molecular dynamics simulations.

    PubMed

    Mori, Yoshiharu; Okamoto, Yuko

    2013-02-01

    A simulated tempering method, which is referred to as simulated-tempering umbrella sampling, for calculating the free energy of chemical reactions is proposed. First principles molecular dynamics simulations with this simulated tempering were performed to study the intramolecular proton transfer reaction of malonaldehyde in an aqueous solution. Conformational sampling in reaction coordinate space can be easily enhanced with this method, and the free energy along a reaction coordinate can be calculated accurately. Moreover, the simulated-tempering umbrella sampling provides trajectory data more efficiently than the conventional umbrella sampling method.

  13. Dispensing of very low volumes of ultra high viscosity alginate gels: a new tool for encapsulation of adherent cells and rapid prototyping of scaffolds and implants.

    PubMed

    Gepp, Michael M; Ehrhart, Friederike; Shirley, Stephen G; Howitz, Steffen; Zimmermann, Heiko

    2009-01-01

    We present a tool for dispensing very low volumes (20 nL or more) of ultra high viscosity (UHV) medical-grade alginate hydrogels. It uses a modified piezo-driven micrometering valve, integrated into a versatile system that allows fast prototyping of encapsulation procedures and scaffold production. Valves show excellent dispensing properties for UHV alginate in concentrations of 0.4% and 0.7% and also for aqueous liquids. An optimized process flow provides excellent handling of biological samples under sterile conditions. This technique allows the encapsulation of adherent cells and structuring of substrates for biotechnology and regenerative medicine. A variety of cell lines showed at least 70% viability after encapsulation (including cell lines that are relevant in regenerative medicine like Hep G2), and time-lapse analysis revealed cells proliferating and showing limited motility under alginate spots. Cells show metabolic activity, gene product expression, and physiological function. Encapsulated cells have contact with the substrate and can exchange metabolites while being isolated from macromolecules in the environment. Contactless dispensing allows structuring of substrates with alginate, isolation and transfer of cell-alginate complexes, and the dispensing of biological active hydrogels like extracellular matrix-derived gels.

  14. A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaefer-Nolte, E.; Wrachtrup, J.; 3rd Institute of Physics and Research Center SCoPE, University Stuttgart, 70569 Stuttgart

    2014-01-15

    We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines amore » tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.« less

  15. Ultrahigh Vacuum Scanning Tunneling Microscopy and Spectroscopy of Single-Walled Carbon Nanotubes Interfaced with Silicon Surfaces

    NASA Astrophysics Data System (ADS)

    Albrecht, Peter; Lyding, Joseph

    2008-03-01

    The UHV-STM was used to examine SWNTs directly interfaced with hydrogen-passivated Si(100). Dry contact transfer (DCT) [1] enabled the UHV deposition of SWNTs with minimal disruption of the atomically flat Si(100)-2x1:H surface. Isolated, rather than bundled, SWNTs could be routinely located for atomically resolved imaging, tunneling I-V spectroscopy [2], lateral manipulation [3], and proximal substrate modification. Weakly adsorbed SWNTs initially unstable in the presence of the rastered STM tip could be stabilized by depassivating the underlying H-Si(100) surface via UHV-STM electron-stimulated H desorption [4], which in the case of one chiral semiconducting SWNT also promoted the local alignment of the zigzag symmetry direction on the underside of the tube with the clean Si dimer rows [5]. The growing body of first-principles simulations of the SWNT/Si(100) system [6] was drawn upon in our interpretation of such local perturbations. [1] APL 83, 5029 (2003). [2] Nanotechnology 18, 095204 (2007). [3] Small 3, 146 (2007). [4] Nanotechnology 18, 125302 (2007). [5] Small 3, 1402 (2007). [6] JAP 100, 124304 (2006).

  16. Nonparametric Transfer Function Models

    PubMed Central

    Liu, Jun M.; Chen, Rong; Yao, Qiwei

    2009-01-01

    In this paper a class of nonparametric transfer function models is proposed to model nonlinear relationships between ‘input’ and ‘output’ time series. The transfer function is smooth with unknown functional forms, and the noise is assumed to be a stationary autoregressive-moving average (ARMA) process. The nonparametric transfer function is estimated jointly with the ARMA parameters. By modeling the correlation in the noise, the transfer function can be estimated more efficiently. The parsimonious ARMA structure improves the estimation efficiency in finite samples. The asymptotic properties of the estimators are investigated. The finite-sample properties are illustrated through simulations and one empirical example. PMID:20628584

  17. Mechanisms of Learning Transfer in Adventure Education: Qualitative Results from the NOLS Transfer Survey

    ERIC Educational Resources Information Center

    Sibthorp, Jim; Furman, Nate; Paisley, Karen; Gookin, John; Schumann, Scott

    2011-01-01

    Transfer of learning from adventure programs remains of critical interest to adventure education professionals. Although some research has investigated what transfers, notably less has focused on mechanisms that might influence transfer. This paper explores the mechanisms of transfer reported by a stratified random sample of National Outdoor…

  18. Exploring the Critical Role of Motivation to Transfer in the Training Transfer Process

    ERIC Educational Resources Information Center

    Grohmann, Anna; Beller, Johannes; Kauffeld, Simone

    2014-01-01

    The present study aims at exploring the critical role of motivation to transfer within the training transfer process. In a sample of N?=?252 employees of one industrial company, one peer rating and several self-ratings of transfer were used to investigate the mediating role of motivation to transfer in the relationship between training…

  19. Martian Radiative Transfer Modeling Using the Optimal Spectral Sampling Method

    NASA Technical Reports Server (NTRS)

    Eluszkiewicz, J.; Cady-Pereira, K.; Uymin, G.; Moncet, J.-L.

    2005-01-01

    The large volume of existing and planned infrared observations of Mars have prompted the development of a new martian radiative transfer model that could be used in the retrievals of atmospheric and surface properties. The model is based on the Optimal Spectral Sampling (OSS) method [1]. The method is a fast and accurate monochromatic technique applicable to a wide range of remote sensing platforms (from microwave to UV) and was originally developed for the real-time processing of infrared and microwave data acquired by instruments aboard the satellites forming part of the next-generation global weather satellite system NPOESS (National Polarorbiting Operational Satellite System) [2]. As part of our on-going research related to the radiative properties of the martian polar caps, we have begun the development of a martian OSS model with the goal of using it to perform self-consistent atmospheric corrections necessary to retrieve caps emissivity from the Thermal Emission Spectrometer (TES) spectra. While the caps will provide the initial focus area for applying the new model, it is hoped that the model will be of interest to the wider Mars remote sensing community.

  20. Moment-to-Moment Transfer of Positive Emotions in Daily Life Predicts Future Course of Depression in Both General Population and Patient Samples

    PubMed Central

    Höhn, Petra; Menne-Lothmann, Claudia; Peeters, Frenk; Nicolson, Nancy A.; Jacobs, Nele; Derom, Catherine; Thiery, Evert; van Os, Jim; Wichers, Marieke

    2013-01-01

    Objective Positive affect (PA) is closely linked to prevention of, and recovery from, depression. Previous studies have investigated PA reactivity to pleasant situations with respect to its protective properties in relation to mood disorder. The purpose of this study was to examine, and replicate, whether moment-to-moment transfer of PA in daily life (PA persistence) is relevant to the prediction of future course of depression. Method Individuals from three different studies (one general population sample (n=540), and two patient samples (n=43 and n=50) with matching controls (n=39 and n=21, respectively)) participated in an Experience Sampling Method (ESM) study. Time-lagged multilevel analyses were used to assess the degree of transfer (or persistence) of momentary positive affective states over time, in relation to naturalistic outcome (study 1) or treatment outcome (studies 2 and 3). Depressive symptoms were measured using the Symptom Checklist (SCL-90R) in sample 1 and the Hamilton Depression Rating Scale (HDRS) in samples 2 and 3. Results In study 1, participants with greater momentary PA persistence were less likely to show depressive symptoms at follow-up. In study 2, patients were more likely to respond to treatment if they displayed greater momentary PA persistence, particularly in those with recurrent depression. In study 3, patients with greater momentary PA persistence were similarly more likely to respond to treatment, especially when treated with imipramine rather than placebo. Conclusion The ability to transfer PA from one moment to the next is an important factor in the prevention of and recovery from depressive symptoms. Patients with recurrent depression and those who receive antidepressants rather than placebo may benefit most from this effect. The results suggest that treatment-induced improvement in depression is mediated by increased levels of momentary transfer of PA in daily life, acquisition of which may be contingent on duration of

  1. A Sample Return Container with Hermetic Seal

    NASA Technical Reports Server (NTRS)

    Kong, Kin Yuen; Rafeek, Shaheed; Sadick, Shazad; Porter, Christopher C.

    2000-01-01

    A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers and then hermetically seal samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the sampler's featured drill tip for interfacing, transfer-ring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses a few isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The drill based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. Again, the sampler provides all sealing actuation. This sample return container and co-engineered sample acquisition system are being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program.

  2. Planetary Sample Caching System Design Options

    NASA Technical Reports Server (NTRS)

    Collins, Curtis; Younse, Paulo; Backes, Paul

    2009-01-01

    Potential Mars Sample Return missions would aspire to collect small core and regolith samples using a rover with a sample acquisition tool and sample caching system. Samples would need to be stored in individual sealed tubes in a canister that could be transfered to a Mars ascent vehicle and returned to Earth. A sample handling, encapsulation and containerization system (SHEC) has been developed as part of an integrated system for acquiring and storing core samples for application to future potential MSR and other potential sample return missions. Requirements and design options for the SHEC system were studied and a recommended design concept developed. Two families of solutions were explored: 1)transfer of a raw sample from the tool to the SHEC subsystem and 2)transfer of a tube containing the sample to the SHEC subsystem. The recommended design utilizes sample tool bit change out as the mechanism for transferring tubes to and samples in tubes from the tool. The SHEC subsystem design, called the Bit Changeout Caching(BiCC) design, is intended for operations on a MER class rover.

  3. Heat transfer through the flat surface of Rutherford superconducting cable samples with novel pattern of electrical insulation immersed in He II

    NASA Astrophysics Data System (ADS)

    Strychalski, M.; Chorowski, M.; Polinski, J.

    2014-05-01

    Future accelerator magnets will be exposed to heat loads that exceed even by an order of magnitude presently observed heat fluxes transferred to superconducting magnet coils. To avoid the resistive transition of the superconducting cables, the efficiency of heat transfer between the magnet structure and the helium must be significantly increased. This can be achieved through the use of novel concepts of the cable’s electrical insulation wrapping, characterized by an enhanced permeability to helium while retaining sufficient electrical resistivity. This paper presents measurement results of the heat transfer through Rutherford NbTi cable samples immersed in a He II bath and subjected to the pressure loads simulating the counteracting of the Lorentz forces observed in powered magnets. The Rutherford cable samples that were tested used different electrical insulation wrapping schemes, including the scheme that is presently used and the proposed scheme for future LHC magnets. A new porous polyimide cable insulation with enhanced helium permeability was proposed in order to improve the evacuation of heat form the NbTi coil to He II bath. These tests were performed in a dedicated Claudet-type cryostat in pressurized He II at 1.9 K and 1 bar.

  4. New experimental perspectives for soft x-ray absorption spectroscopies at ultra-low temperatures below 50 mK and in high magnetic fields up to 7 T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beeck, T., E-mail: torben.beeck@desy.de; Baev, I.; Gieschen, S.

    2016-04-15

    A new ultra-low temperature experiment including a superconducting vector magnet has been developed for soft x-ray absorption spectroscopy experiments at third generation synchrotron light sources. The sample is cooled below 50 mK by a cryogen free {sup 3}He-{sup 4}He dilution refrigerator. At the same time, magnetic fields of up to ±7 T in the horizontal direction and ±0.5 T in the vertical direction can be applied by a superconducting vector magnet. The setup allows to study ex situ and in situ prepared samples, offered by an attached UHV preparation chamber with load lock. The transfer of the prepared samples betweenmore » the preparation section and the dilution refrigerator is carried out under cryogenic temperatures. First commissioning studies have been carried out at the Variable Polarization XUV Beamline P04 at PETRA III and the influence of the incident photon beam to the sample temperature has been studied.« less

  5. Surface science approach to Pt/carbon model catalysts: XPS, STM and microreactor studies

    NASA Astrophysics Data System (ADS)

    Motin, Abdul Md.; Haunold, Thomas; Bukhtiyarov, Andrey V.; Bera, Abhijit; Rameshan, Christoph; Rupprechter, Günther

    2018-05-01

    Pt nanoparticles supported on carbon are an important technological catalyst. A corresponding model catalyst was prepared by physical vapor deposition (PVD) of Pt on sputtered HOPG (highly oriented pyrolytic graphite). The carbon substrate before and after sputtering as well as the Pt/HOPG system before and after Pt deposition and annealing were examined by XPS and STM. This yielded information on the surface density of defects, which serve as nucleation centres for Pt, and on the size distribution (mean size/height) of the Pt nanoparticles. Two different model catalysts were prepared with mean sizes of 2.0 and 3.6 nm, both turned out to be stable upon UHV-annealing to 300 °C. After transfer into a UHV-compatible flow microreactor and subsequent cleaning in UHV and under mbar pressure, the catalytic activity of the Pt/HOPG model system for ethylene hydrogenation was examined under atmospheric pressure flow conditions. This enabled to determine temperature-dependent conversion rates, turnover frequencies (TOFs) and activation energies. The catalytic results obtained are in line with the characteristics of technological Pt/C, demonstrating the validity of the current surface science based model catalyst approach.

  6. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope

    NASA Astrophysics Data System (ADS)

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  7. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope.

    PubMed

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  8. Optimal Subset Selection of Time-Series MODIS Images and Sample Data Transfer with Random Forests for Supervised Classification Modelling

    PubMed Central

    Zhou, Fuqun; Zhang, Aining

    2016-01-01

    Nowadays, various time-series Earth Observation data with multiple bands are freely available, such as Moderate Resolution Imaging Spectroradiometer (MODIS) datasets including 8-day composites from NASA, and 10-day composites from the Canada Centre for Remote Sensing (CCRS). It is challenging to efficiently use these time-series MODIS datasets for long-term environmental monitoring due to their vast volume and information redundancy. This challenge will be greater when Sentinel 2–3 data become available. Another challenge that researchers face is the lack of in-situ data for supervised modelling, especially for time-series data analysis. In this study, we attempt to tackle the two important issues with a case study of land cover mapping using CCRS 10-day MODIS composites with the help of Random Forests’ features: variable importance, outlier identification. The variable importance feature is used to analyze and select optimal subsets of time-series MODIS imagery for efficient land cover mapping, and the outlier identification feature is utilized for transferring sample data available from one year to an adjacent year for supervised classification modelling. The results of the case study of agricultural land cover classification at a regional scale show that using only about a half of the variables we can achieve land cover classification accuracy close to that generated using the full dataset. The proposed simple but effective solution of sample transferring could make supervised modelling possible for applications lacking sample data. PMID:27792152

  9. Optimal Subset Selection of Time-Series MODIS Images and Sample Data Transfer with Random Forests for Supervised Classification Modelling.

    PubMed

    Zhou, Fuqun; Zhang, Aining

    2016-10-25

    Nowadays, various time-series Earth Observation data with multiple bands are freely available, such as Moderate Resolution Imaging Spectroradiometer (MODIS) datasets including 8-day composites from NASA, and 10-day composites from the Canada Centre for Remote Sensing (CCRS). It is challenging to efficiently use these time-series MODIS datasets for long-term environmental monitoring due to their vast volume and information redundancy. This challenge will be greater when Sentinel 2-3 data become available. Another challenge that researchers face is the lack of in-situ data for supervised modelling, especially for time-series data analysis. In this study, we attempt to tackle the two important issues with a case study of land cover mapping using CCRS 10-day MODIS composites with the help of Random Forests' features: variable importance, outlier identification. The variable importance feature is used to analyze and select optimal subsets of time-series MODIS imagery for efficient land cover mapping, and the outlier identification feature is utilized for transferring sample data available from one year to an adjacent year for supervised classification modelling. The results of the case study of agricultural land cover classification at a regional scale show that using only about a half of the variables we can achieve land cover classification accuracy close to that generated using the full dataset. The proposed simple but effective solution of sample transferring could make supervised modelling possible for applications lacking sample data.

  10. CO Adsorption on Reconstructed Ir(100) Surfaces from UHV to mbar Pressure: A LEED, TPD, and PM-IRAS Study

    PubMed Central

    2016-01-01

    Clean and stable surface modifications of an iridium (100) single crystal, i.e., the (1 × 1) phase, the (5 × 1) reconstruction, and the oxygen-terminated (2 × 1)-O surface, were prepared and characterized by low energy electron diffraction (LEED), temperature-programmed desorption (TPD), infrared reflection absorption spectroscopy (IRAS) and polarization modulation IRAS (PM-IRAS). The adsorption of CO in UHV and at elevated (mbar) pressure/temperature was followed both ex situ and in situ on all three surface modifications, with a focus on mbar pressures of CO. The Ir(1 × 1) surface exhibited c(4 × 2)/c(2 × 2) and c(6 × 2) CO structures under low pressure conditions, and remained stable up to 100 mbar and 700 K. For the (2 × 1)-O reconstruction CO adsorption induced a structural change from (2 × 1)-O to (1 × 1), as confirmed by LEED, TPD, and IR. For Ir (2 × 1)-O TPD indicated that CO reacted with surface oxygen forming CO2. The (5 × 1) reconstruction featured a reversible and dynamic behavior upon CO adsorption, with a local lifting of the reconstruction to (1 × 1). After CO desorption, the (5 × 1) structure was restored. All three reconstructions exhibited CO adsorption with on-top geometry, as evidenced by IR. With increasing CO exposure the resonances shifted to higher wavenumber, due to adsorbate–adsorbate and adsorbate–substrate interactions. The largest wavenumber shift (from 2057 to 2100 cm–1) was observed for Ir(5 × 1) upon CO dosing from 1 L to 100 mbar. PMID:27257467

  11. Lateral Gene Transfer from the Dead

    PubMed Central

    Szöllősi, Gergely J.; Tannier, Eric; Lartillot, Nicolas; Daubin, Vincent

    2013-01-01

    In phylogenetic studies, the evolution of molecular sequences is assumed to have taken place along the phylogeny traced by the ancestors of extant species. In the presence of lateral gene transfer, however, this may not be the case, because the species lineage from which a gene was transferred may have gone extinct or not have been sampled. Because it is not feasible to specify or reconstruct the complete phylogeny of all species, we must describe the evolution of genes outside the represented phylogeny by modeling the speciation dynamics that gave rise to the complete phylogeny. We demonstrate that if the number of sampled species is small compared with the total number of existing species, the overwhelming majority of gene transfers involve speciation to and evolution along extinct or unsampled lineages. We show that the evolution of genes along extinct or unsampled lineages can to good approximation be treated as those of independently evolving lineages described by a few global parameters. Using this result, we derive an algorithm to calculate the probability of a gene tree and recover the maximum-likelihood reconciliation given the phylogeny of the sampled species. Examining 473 near-universal gene families from 36 cyanobacteria, we find that nearly a third of transfer events (28%) appear to have topological signatures of evolution along extinct species, but only approximately 6% of transfers trace their ancestry to before the common ancestor of the sampled cyanobacteria. [Gene tree reconciliation; lateral gene transfer; macroevolution; phylogeny.] PMID:23355531

  12. Robotic Arm Manipulator Using Active Control for Sample Acquisition and Transfer, and Passive Mode for Surface Compliance

    NASA Technical Reports Server (NTRS)

    Liu, Jun; Underhill, Michael L.; Trease, Brian P.; Lindemann, Randel A.

    2010-01-01

    A robotic arm that consists of three joints with four degrees of freedom (DOF) has been developed. It can carry an end-effector to acquire and transfer samples by using active control and comply with surface topology in a passive mode during a brief surface contact. The three joints are arranged in such a way that one joint of two DOFs is located at the shoulder, one joint of one DOF is located at the elbow, and one joint of one DOF is located at the wrist. Operationally, three DOFs are moved in the same plane, and the remaining one on the shoulder is moved perpendicular to the other three for better compliance with ground surface and more flexibility of sample handling. Three out of four joints are backdriveable, making the mechanism less complex and more cost effective

  13. Through oven transfer adsorption-desorption interface for the analysis of methyl jasmonate in aromatic samples by on-line RPLC-GC.

    PubMed

    Flores, Gema; Blanch, Gracia Patricia; Ruiz del Castillo, Maria Luisa

    2008-04-01

    A fully automated method for the determination of medium volatility compounds in aromatic samples was developed. Specifically, the determination of methyl jasmonate in jasmine fragrances was performed by using the through oven transfer adsorption-desorption (TOTAD) interface for the on-line coupling between RPLC-GC. A study of the most relevant variables involved in the performance of the TOTAD interface for medium volatility compounds was carried out by testing different values of helium flow (100, 300, 400, and 500 mL/min), transfer speed (0.1, 0.3, 0.5, and 2.0 mL/min), and methanol/water percentages (86:14, 85:15, 83:17, 80:20, and 70:30). The method developed provided satisfactory repeatability (RSD for retention times of 0.15% and for peak areas of 9.4%) and recovery (71%) as well as excellent LOD (0.01 mg/L) for methyl jasmonate in commercial jasmine essence under the experimental conditions selected as optimum. Additional advantages of the automated RPLC-TOTAD-GC method proposed in the present work are its rapidness, reliability, and the possibility of directly introducing the sample with no further pretreatment.

  14. Stabilization of non-productive conformations underpins rapid electron transfer to electron-transferring flavoprotein.

    PubMed

    Toogood, Helen S; van Thiel, Adam; Scrutton, Nigel S; Leys, David

    2005-08-26

    Crystal structures of protein complexes with electron-transferring flavoprotein (ETF) have revealed a dual protein-protein interface with one region serving as anchor while the ETF FAD domain samples available space within the complex. We show that mutation of the conserved Glu-165beta in human ETF leads to drastically modulated rates of interprotein electron transfer with both medium chain acyl-CoA dehydrogenase and dimethylglycine dehydrogenase. The crystal structure of free E165betaA ETF is essentially identical to that of wild-type ETF, but the crystal structure of the E165betaA ETF.medium chain acyl-CoA dehydrogenase complex reveals clear electron density for the FAD domain in a position optimal for fast interprotein electron transfer. Based on our observations, we present a dynamic multistate model for conformational sampling that for the wild-type ETF. medium chain acyl-CoA dehydrogenase complex involves random motion between three distinct positions for the ETF FAD domain. ETF Glu-165beta plays a key role in stabilizing positions incompatible with fast interprotein electron transfer, thus ensuring high rates of complex dissociation.

  15. NEA Multi-Chamber Sample Return Container with Hermetic Sealing

    NASA Technical Reports Server (NTRS)

    Rafeek, Shaheed; Kong, Kin Yuen; Sadick, Shazad; Porter, Christopher C.

    2000-01-01

    A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers such as the 'Touch and Go' Surface Sampler (TGSS), and then hermetically seal the samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the rotation axis of the TGSS sampler for interfacing, transferring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses multiple isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The TGSS based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. This sample return container is being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program. A breadboard system of the sample return container has been recently completed and tested. Additional information is contained in the original extended abstract.

  16. The complexities of DNA transfer during a social setting.

    PubMed

    Goray, Mariya; van Oorschot, Roland A H

    2015-03-01

    When questions relating to how a touch DNA sample from a specific individual got to where it was sampled from, one has limited data available to provide an assessment on the likelihood of specific transfer events within a proposed scenario. This data is mainly related to the impact of some key variables affecting transfer that are derived from structured experiments. Here we consider the effects of unstructured social interactions on the transfer of touch DNA. Unscripted social exchanges of three individuals having a drink together while sitting at a table were video recorded and DNA samples were collected and profiled from all relevant items touched during each sitting. Attempts were made to analyze when and how DNA was transferred from one object to another. The analyses demonstrate that simple minor everyday interactions involving only a few items in some instances lead to detectable DNA being transferred among individuals and objects without them having contacted each other through secondary and further transfer. Transfer was also observed to be bi-directional. Furthermore, DNA of unknown source on hands or objects can be transferred and interfere with the interpretation of profiles generated from targeted touched surfaces. This study provides further insight into the transfer of DNA that may be useful when considering the likelihood of alternate scenarios of how a DNA sample got to where it was found. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. An ultrahigh vacuum fast-scanning and variable temperature scanning tunneling microscope for large scale imaging.

    PubMed

    Diaconescu, Bogdan; Nenchev, Georgi; de la Figuera, Juan; Pohl, Karsten

    2007-10-01

    We describe the design and performance of a fast-scanning, variable temperature scanning tunneling microscope (STM) operating from 80 to 700 K in ultrahigh vacuum (UHV), which routinely achieves large scale atomically resolved imaging of compact metallic surfaces. An efficient in-vacuum vibration isolation and cryogenic system allows for no external vibration isolation of the UHV chamber. The design of the sample holder and STM head permits imaging of the same nanometer-size area of the sample before and after sample preparation outside the STM base. Refractory metal samples are frequently annealed up to 2000 K and their cooldown time from room temperature to 80 K is 15 min. The vertical resolution of the instrument was found to be about 2 pm at room temperature. The coarse motor design allows both translation and rotation of the scanner tube. The total scanning area is about 8 x 8 microm(2). The sample temperature can be adjusted by a few tens of degrees while scanning over the same sample area.

  18. Filter paper-assisted cell transfer (FaCT) technique: A novel cell-sampling technique for intraoperative diagnosis of central nervous system tumors.

    PubMed

    Kawamura, Jumpei; Kamoshida, Shingo; Shimakata, Takaaki; Hayashi, Yurie; Sakamaki, Kuniko; Denda, Tamami; Kawai, Kenji; Kuwao, Sadahito

    2017-04-01

    Intraoperative diagnosis of central nervous system (CNS) tumors provides critical guidance to surgeons in the determination of surgical resection margins and treatment. The techniques and preparations used for the intraoperative diagnosis of CNS tumors include frozen sectioning and cytologic methods (squash smear and touch imprint). Cytologic specimens, which do not have freezing artifacts, are important as an adjuvant tool to frozen sections. However, if the amount of submitted tissue samples is limited, then it is difficult to prepare both frozen sections and squash smears or touch imprint specimens from a single sample at the same time. Therefore, the objective of this study was to derive cells directly from filter paper on which tumor samples are placed. The authors established the filter paper-assisted cell transfer (FaCT) smear technique, in which tumor cells are transferred onto a glass slide directly from the filter paper sample spot after the biopsy is removed. Cell yields and diagnostic accuracy of the FaCT smears were assessed in 40 CNS tumors. FaCT smears had ample cell numbers and well preserved cell morphology sufficient for cytologic diagnosis, even if the submitted tissues were minimal. The overall diagnostic concordance rates between frozen sections and FaCT smears were 90% and 87.5%, respectively (no significant differences). When combining FaCT smears with frozen sections, the diagnostic concordance rate rose to 92.5%. The current results suggest that the FaCT smear technique is a simple and effective processing method that has significant value for intraoperative diagnosis of CNS tumors. Cancer Cytopathol 2017;125:277-282. © 2016 American Cancer Society. © 2017 American Cancer Society.

  19. Isomer Profiles of Perfluorochemicals in Matched Maternal, Cord, and House Dust Samples: Manufacturing Sources and Transplacental Transfer

    PubMed Central

    Beesoon, Sanjay; Webster, Glenys M.; Shoeib, Mahiba; Harner, Tom; Benskin, Jonathan P.

    2011-01-01

    Background: Perfluorochemicals (PFCs) are detectable in the general population and in the human environment, including house dust. Sources are not well characterized, but isomer patterns should enable differentiation of historical and contemporary manufacturing sources. Isomer-specific maternal–fetal transfer of PFCs has not been examined despite known developmental toxicity of perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) in rodents. Objectives: We elucidated relative contributions of electrochemical (phased out in 2001) and telomer (contemporary) PFCs in dust and measured how transplacental transfer efficiency (TTE; based on a comparison of maternal and cord sera concentrations) is affected by perfluorinated chain length and isomer branching pattern. Methods: We analyzed matching samples of house dust (n = 18), maternal sera (n = 20), and umbilical cord sera (n = 20) by isomer-specific high-performance liquid chromatography tandem mass spectrometry. Results: PFOA isomer signatures revealed that telomer sources accounted for 0–95% of total PFOA in house dust (median, 31%). This may partly explain why serum PFOA concentrations are not declining in some countries despite the phase-out of electrochemical PFOA. TTE data indicate that total branched isomers crossed the placenta more efficiently than did linear isomers for both PFOS (p < 0.01) and PFOA (p = 0.02) and that placental transfer of branched isomers of PFOS increased as the branching point moved closer to the sulfonate (SO3–) end of the molecule. Conclusions: Results suggest that humans are exposed to telomer PFOA, but larger studies that also account for dietary sources should be conducted. The exposure profile of PFOS and PFOA isomers can differ between the mother and fetus—an important consideration for perinatal epidemiology studies of PFCs. PMID:21757419

  20. Method for producing an atomic oxygen beam

    NASA Technical Reports Server (NTRS)

    Outlaw, Ronald A. (Inventor)

    1989-01-01

    A method for producing an atomic oxygen beam is provided by the present invention. First, a material 10' is provided which dissociates molecular oxygen and dissolves atomic oxygen into its bulk. Next, molecular oxygen is exposed to entrance surface 11' of material 10'. Next, material 10' is heated by heater 17' to facilitate the permeation of atomic oxygen through material 10' to the UHV side 12'. UHV side 12' is interfaced with an ultra-high vacuum (UHV) environment provided by UHV pump 15'. The atomic oxygen on the UHV side 12' is excited to a non-binding state by exciter 14' thus producing the release of atomic oxygen to form an atomic oxygen beam 35'.

  1. Hot steam transfer through heat protective clothing layers.

    PubMed

    Rossi, René; Indelicato, Eric; Bolli, Walter

    2004-01-01

    The aim of this study was to analyse the transfer of steam through different types of textile layers as a function of sample parameters such as thickness and permeability. In order to simulate the human body, a cylinder releasing defined amounts of moisture was also used. The influence of sweating on heat and mass transfer was assessed. The results show that in general impermeable materials offer better protection against hot steam than semi-permeable ones. The transfer of steam depended on the water vapour permeability of the samples, but also on their thermal insulation and their thickness. Increasing the thickness of the samples with a spacer gave a larger increase in protection with the impermeable samples compared to semi-permeable materials. Measurements with pre-wetted samples showed a reduction in steam protection in any case. On the other hand, the measurements with a sweating cylinder showed a beneficial effect of sweating.

  2. Transfer Policies, Career, and Family: Are They Compatible?

    ERIC Educational Resources Information Center

    Gerstmann, Timothy K.

    The effects of business transfers on families were studied through family impact analysis. A small sample (10 couples) of dual-career and dual-worker couples was utilized for the project. The sample was unusual in that both partners were employed by the same company. Four areas were examined for possible impacts of a transfer on the family: family…

  3. Four-probe measurements with a three-probe scanning tunneling microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salomons, Mark; Martins, Bruno V. C.; Zikovsky, Janik

    2014-04-15

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position bymore » imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.« less

  4. Four-probe measurements with a three-probe scanning tunneling microscope.

    PubMed

    Salomons, Mark; Martins, Bruno V C; Zikovsky, Janik; Wolkow, Robert A

    2014-04-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  5. Heat Transfer In High-Temperature Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Miller, Stephen D.; Cunnington, George R.

    2006-01-01

    The combined radiation/conduction heat transfer in high-temperature multilayer insulations for typical reentry of reusable launch vehicles from low Earth orbit was investigated experimentally and numerically. The high-temperature multilayer insulation investigated consisted of gold-coated reflective foils separated by alumina fibrous insulation spacers. The steady-state heat transfer through four multilayer insulation configurations was investigated experimentally over the temperature range of 300-1300 K and environmental pressure range of 1.33 10(exp -5)-101.32 kPa. It was shown that including the reflective foils reduced the effective thermal conductivity compared to fibrous insulation sample at 1.5 times the density of the multilayer sample. A finite volume numerical model was developed to solve the governing combined radiation/conduction heat transfer equations. The radiation heat transfer in the fibrous insulation spacers was modeled using the modified two-flux approximation assuming anisotropic scattering and gray medium. The numerical model was validated by comparison with steady-state experimental data. The root mean square deviation between the predicted and measured effective thermal conductivity of the samples was 9.5%.

  6. Evaluation of standardized sample collection, packaging, and ...

    EPA Pesticide Factsheets

    Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.

  7. In-situ ellipsometric studies of optical and surface properties of GaAs(100) at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Yao, Huade; Snyder, Paul G.

    1991-01-01

    A rotating-polarizer ellipsometer was attached to an ultrahigh vacuum (UHV) chamber. A GaAs(100) sample was introduced into the UHV chamber and heated at anumber of fixed elevated temperatures, without arsenic overpressure. In-situ spectroscopic ellipsometric (SE) measurements were taken, through a pair of low-strain quartz windows, to monitor the surface changes and measure the pseudodielectric functions at elevated temperatures. Real-time data from GaAs surface covered with native oxide showed clearly the evolution of oxide desorption at approximately 580 C. In addition, surface degradation was found before and after the oxide desorption. An oxide free and smooth GaAs surface was obtained by depositing an arsenic protective coating onto a molecular beam epitaxy grown GaAs surface. The arsenic coating was evaporated immediately prior to SE measurements. A comparison showed that our room temperature data from this GaAs surface, measured in the UHV, are in good agreement with those in the literature obtained by wet-chemical etching. The surface also remained clean and smooth at higher temperatures, so that reliable temperature-dependent dielectric functions were obtained.

  8. Design of an Operando Positron Annihilation Gamma Spectrometer (OPAGS)

    NASA Astrophysics Data System (ADS)

    Satyal, Suman; Shastry, Kartik; Kalaskar, Sushant; Lim, Larry; Joglekar, Vibek; Weiss, Alexander

    2009-10-01

    Surface properties measured under UHV conditions cannot be extended to surfaces interacting with gases under realistic pressures due to surface reconstruction and other strong perturbations of the surface. Many surface probing techniques used till now have required UHV conditions to avoid data loss due to scattering of outgoing particles. Here we describe the design of an Operando Positron Annihilation Gamma Spectrometer (OPAGS) currently under construction at the University of Texas at Arlington. The new system will be capable of obtaining surface and defect specific chemical and charge state information from surfaces under realistic pressures. Differential pumping will be used to maintain the sample in a gas environment while the rest of the beam is under UHV. The Elemental content of the surface interacting with the gas environment will be determined from the Doppler broadened gamma spectra. This system will also include a time of flight (TOF) positron annihilation induced Auger spectrometer (TOF-PAES) for use in combined annihilation induced Auger and annihilation gamma measurements made under low pressure conditions.

  9. Characterization of Mullite-Zirconia Composite Processed by Non-Transferred and Transferred Arc Plasma

    NASA Astrophysics Data System (ADS)

    Yugeswaran, S.; Selvarajan, V.; Lusvarghi, L.; I. Y. Tok, A.; D. Siva Rama, Krishna

    2009-04-01

    The arc plasma melting technique is a simple method to synthesize high temperature reaction composites. In this study, mullite-zirconia composite was synthesized by transferred and non-transferred arc plasma melting, and the results were compared. A mixture of alumina and zircon powders with a mole ratio of 3: 2 were ball milled for four hours and melted for two minutes in the transferred and non-transferred mode of plasma arcs. Argon and air were used as plasma forming gases. The phase and microstructural formation of melted samples were investigated by X-ray diffraction (XRD) and scanning electron microscope (SEM). The microstructure of the composites was found to be affected by the mode of melting. In transferred arc melting, zirconia flowers with uniform lines along with mullite whiskers were obtained. In the case of non-transferred arc plasma melting, mullite whiskers along with star shape zirconia were formed. Differential thermal analysis (DTA) of the synthesized mullite-zirconia composites provided a deeper understanding of the mechanisms of mullite formation during the two different processes.

  10. Detection of proteins on blot transfer membranes.

    PubMed

    Sasse, Joachim; Gallagher, Sean R

    2003-11-01

    In the basic and alternate protocols of this unit, proteins are stained after electroblotting from polyacrylamide gels to blot transfer membranes. If the samples of interest are electrophoresed in duplicate and transferred to a blot transfer membrane, half of the membrane can be stained to determine the efficiency of transfer to the membrane and the other half can be used for immunoblotting (i.e., western blotting). Detection limits of each staining method are given along with a list of compatible blot transfer membranes and gels. A support protocol describes a method for alkali treatment that enhances subsequent staining of bound proteins.

  11. Hydride Transfer in DHFR by Transition Path Sampling, Kinetic Isotope Effects, and Heavy Enzyme Studies

    PubMed Central

    Wang, Zhen; Antoniou, Dimitri; Schwartz, Steven D.; Schramm, Vern L.

    2016-01-01

    Escherichia coli dihydrofolate reductase (ecDHFR) is used to study fundamental principles of enzyme catalysis. It remains controversial whether fast protein motions are coupled to the hydride transfer catalyzed by ecDHFR. Previous studies with heavy ecDHFR proteins labeled with 13C, 15N, and nonexchangeable 2H reported enzyme mass-dependent hydride transfer kinetics for ecDHFR. Here, we report refined experimental and computational studies to establish that hydride transfer is independent of protein mass. Instead, we found the rate constant for substrate dissociation to be faster for heavy DHFR. Previously reported kinetic differences between light and heavy DHFRs likely arise from kinetic steps other than the chemical step. This study confirms that fast (femtosecond to picosecond) protein motions in ecDHFR are not coupled to hydride transfer and provides an integrative computational and experimental approach to resolve fast dynamics coupled to chemical steps in enzyme catalysis. PMID:26652185

  12. Kinetic disposition of lorazepam with focus on the glucuronidation capacity, transplacental transfer in parturients and racemization in biological samples.

    PubMed

    Papini, Olga; da Cunha, Sergio Pereira; da Silva Mathes, Angelo do Carmo; Bertucci, Carlo; Moisés, Elaine Christine Dantas; de Barros Duarte, Luciana; de Carvalho Cavalli, Ricardo; Lanchote, Vera Lucia

    2006-02-13

    The present study investigates the kinetic disposition with focus on the racemization, glucuronidation capacity and the transplacental transfer of lorazepam in term parturients during labor. The study was conducted on 10 healthy parturients aged 18-37 years with a gestational age of 36-40.1 weeks, treated with a single oral dose of 2 mg racemic lorazepam 2-9 h before delivery. Maternal venous blood and urine samples were obtained over a 0-48 h interval and the umbilical cord sample was obtained immediately after clamping. Lorazepam enantiomers were determined in plasma and urine samples by LC-MS/MS using a Chiralcel OD-R column. In vitro racemization of lorazepam required the calculation of the pharmacokinetic parameters as isomeric mixtures. The data were fitted to two-compartment model and the pharmacokinetic parameters are reported as means (95% CI): t(1/2a) 3.2h (2.6-3.7 h), K(a) 0.23 h(-1) (0.19-0.28 h(-1)), t(1/2) 10.4h (9.4-11.3h), beta 0.068 h(-1) (0.061-0.075h(-1)), AUC(0-infinity) 175.3(ngh)/ml (145.7-204.8(ngh)/ml), Cl/F 2.6 ml/(minkg) (2.3-2.9 ml/(minkg)), Vd/F178.8l (146.5-211.1l), Fel 0.3% (0.1-0.5%), and Cl(R) 0.010 ml/(minkg) (0.005-0.015 ml/(minkg)). Placental transfer of lorazepam evaluated as the ratio of vein umbilical/maternal vein plasma concentrations, obtained as an isomeric mixture, was 0.73 (0.52-0.94). Pregnancy changes the pharmacokinetics of lorazepam, with an increase in the apparent distribution volume, an increase in apparent oral clearance, and a reduction of elimination half-life. The increase in oral clearance may indicate an increase in glucuronidation capacity, with a possible reduction in the plasma concentrations of drugs depending on glucuronidation capacity as the major metabolic pathway.

  13. Transferring mixtures of chemicals from sediment to a bioassay using silicone-based passive sampling and dosing.

    PubMed

    Mustajärvi, Lukas; Eriksson-Wiklund, Ann-Kristin; Gorokhova, Elena; Jahnke, Annika; Sobek, Anna

    2017-11-15

    Environmental mixtures of chemicals consist of a countless number of compounds with unknown identity and quantity. Yet, chemical regulation is mainly built around the assessment of single chemicals. Existing frameworks for assessing the toxicity of mixtures require that both the chemical composition and quantity are known. Quantitative analyses of the chemical composition of environmental mixtures are however extremely challenging and resource-demanding. Bioassays may therefore serve as a useful approach for investigating the combined toxicity of environmental mixtures of chemicals in a cost-efficient and holistic manner. In this study, an unknown environmental mixture of bioavailable semi-hydrophobic to hydrophobic chemicals was sampled from a contaminated sediment in a coastal Baltic Sea area using silicone polydimethylsiloxane (PDMS) as an equilibrium passive sampler. The chemical mixture was transferred to a PDMS-based passive dosing system, and its applicability was demonstrated using green algae Tetraselmis suecica in a cell viability assay. The proportion of dead cells increased significantly with increasing exposure level and in a dose-response manner. At an ambient concentration, the proportion of dead cells in the population was nearly doubled compared to the control; however, the difference was non-significant due to high inter-replicate variability and a low number of replicates. The validation of the test system regarding equilibrium sampling, loading efficiency into the passive dosing polymer, stability of the mixture composition, and low algal mortality in control treatments demonstrates that combining equilibrium passive sampling and passive dosing is a promising tool for investigating the toxicity of bioavailable semi-hydrophobic and hydrophobic chemicals in complex environmental mixtures.

  14. Calculating the free energy of transfer of small solutes into a model lipid membrane: Comparison between metadynamics and umbrella sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bochicchio, Davide; Panizon, Emanuele; Ferrando, Riccardo

    2015-10-14

    We compare the performance of two well-established computational algorithms for the calculation of free-energy landscapes of biomolecular systems, umbrella sampling and metadynamics. We look at benchmark systems composed of polyethylene and polypropylene oligomers interacting with lipid (phosphatidylcholine) membranes, aiming at the calculation of the oligomer water-membrane free energy of transfer. We model our test systems at two different levels of description, united-atom and coarse-grained. We provide optimized parameters for the two methods at both resolutions. We devote special attention to the analysis of statistical errors in the two different methods and propose a general procedure for the error estimation inmore » metadynamics simulations. Metadynamics and umbrella sampling yield the same estimates for the water-membrane free energy profile, but metadynamics can be more efficient, providing lower statistical uncertainties within the same simulation time.« less

  15. An environmental transfer hub for multimodal atom probe tomography.

    PubMed

    Perea, Daniel E; Gerstl, Stephan S A; Chin, Jackson; Hirschi, Blake; Evans, James E

    2017-01-01

    Environmental control during transfer between instruments is required for samples sensitive to air or thermal exposure to prevent morphological or chemical changes prior to analysis. Atom probe tomography is a rapidly expanding technique for three-dimensional structural and chemical analysis, but commercial instruments remain limited to loading specimens under ambient conditions. In this study, we describe a multifunctional environmental transfer hub allowing controlled cryogenic or room-temperature transfer of specimens under atmospheric or vacuum pressure conditions between an atom probe and other instruments or reaction chambers. The utility of the environmental transfer hub is demonstrated through the acquisition of previously unavailable mass spectral analysis of an intact organic molecule made possible via controlled cryogenic transfer into the atom probe using the hub. The ability to prepare and transfer specimens in precise environments promises a means to access new science across many disciplines from untainted samples and allow downstream time-resolved in situ atom probe studies.

  16. 7 CFR 27.73 - Supervision of transfers of cotton.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Supervision of transfers of cotton. 27.73 Section 27... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Transfers of Cotton § 27.73 Supervision of transfers of cotton. Whenever the owner of any cotton inspected and sampled for classification...

  17. 7 CFR 27.73 - Supervision of transfers of cotton.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Supervision of transfers of cotton. 27.73 Section 27... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Transfers of Cotton § 27.73 Supervision of transfers of cotton. Whenever the owner of any cotton inspected and sampled for classification...

  18. 7 CFR 27.73 - Supervision of transfers of cotton.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Supervision of transfers of cotton. 27.73 Section 27... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Transfers of Cotton § 27.73 Supervision of transfers of cotton. Whenever the owner of any cotton inspected and sampled for classification...

  19. Radiative transfer and spectroscopic databases: A line-sampling Monte Carlo approach

    NASA Astrophysics Data System (ADS)

    Galtier, Mathieu; Blanco, Stéphane; Dauchet, Jérémi; El Hafi, Mouna; Eymet, Vincent; Fournier, Richard; Roger, Maxime; Spiesser, Christophe; Terrée, Guillaume

    2016-03-01

    Dealing with molecular-state transitions for radiative transfer purposes involves two successive steps that both reach the complexity level at which physicists start thinking about statistical approaches: (1) constructing line-shaped absorption spectra as the result of very numerous state-transitions, (2) integrating over optical-path domains. For the first time, we show here how these steps can be addressed simultaneously using the null-collision concept. This opens the door to the design of Monte Carlo codes directly estimating radiative transfer observables from spectroscopic databases. The intermediate step of producing accurate high-resolution absorption spectra is no longer required. A Monte Carlo algorithm is proposed and applied to six one-dimensional test cases. It allows the computation of spectrally integrated intensities (over 25 cm-1 bands or the full IR range) in a few seconds, regardless of the retained database and line model. But free parameters need to be selected and they impact the convergence. A first possible selection is provided in full detail. We observe that this selection is highly satisfactory for quite distinct atmospheric and combustion configurations, but a more systematic exploration is still in progress.

  20. A Versatile High-Vacuum Cryo-transfer System for Cryo-microscopy and Analytics

    PubMed Central

    Tacke, Sebastian; Krzyzanek, Vladislav; Nüsse, Harald; Wepf, Roger Albert; Klingauf, Jürgen; Reichelt, Rudolf

    2016-01-01

    Cryogenic microscopy methods have gained increasing popularity, as they offer an unaltered view on the architecture of biological specimens. As a prerequisite, samples must be handled under cryogenic conditions below their recrystallization temperature, and contamination during sample transfer and handling must be prevented. We present a high-vacuum cryo-transfer system that streamlines the entire handling of frozen-hydrated samples from the vitrification process to low temperature imaging for scanning transmission electron microscopy and transmission electron microscopy. A template for cryo-electron microscopy and multimodal cryo-imaging approaches with numerous sample transfer steps is presented. PMID:26910419

  1. Transfer Student Engagement: Blurring of Social and Academic Engagement

    ERIC Educational Resources Information Center

    Lester, Jaime; Leonard, Jeannie Brown; Mathias, David

    2013-01-01

    Transfer students are a distinct population. Their characteristics lead to a qualitatively different student experience. Drawing on interviews with a cross-sectional sample of transfer students at George Mason University (GMU), this study focused on the ways transfer students perceived their social and academic engagement, on the ways they engaged…

  2. Transfer of extensor carpi radialis brevis as an extensor to extensor motor transfer (EEMT) in ulnar nerve palsy.

    PubMed

    Jamali, Allah Rakha; Bhatti, Anisuddin; Mehboob, Ghulam

    2006-07-01

    To evaluate functional outcome and correction of deformity with extensor carpiradialis brevis motor transfer to replace the intrinsic muscles as an extensor to extensor motor transfer (EEMT). This was a prospective observational study with one group pretest posttest design conducted from 1996 to 2004. Convenience sampling technique was used and the sample size was twenty one. The independent variable was transfer of extensor carpiradialis brevis to replace the intrinsic muscles. The dependent variable was functional outcome and the correction of deformity. The extraneous variables were age, sex interval between injury and transfer as well as local factors related to wound and grafts used. The average follow up was 22.5 months. The mean preoperative unassisted extensor lag was 56.79 +/- 10.39 which improved to 9.6% +/- 5.4 (correction of 83%) at six months after surgery. With open hand assessment 76.19% reported good to excellent results, while 79.89% achieved good to excellent results with closed hand assessment. The mechanism of closing was good to excellent in 89.42% cases, however only 71.42% patients considered their hands good to excellent. Significant problems were seen with use of tendoachilles as a graft. Extensor carpiradialis brevis transfer to replace the intrinsic muscles as an extensor to extensor motor transfer can achieve good functional outcome as well as correction of deformity despite shortcomings in physical rehabilitation.

  3. Regeneration of LOHC dehydrogenation catalysts: In-situ IR spectroscopy on single crystals, model catalysts, and real catalysts from UHV to near ambient pressure

    NASA Astrophysics Data System (ADS)

    Amende, Max; Kaftan, Andre; Bachmann, Philipp; Brehmer, Richard; Preuster, Patrick; Koch, Marcus; Wasserscheid, Peter; Libuda, Jörg

    2016-01-01

    The Liquid Organic Hydrogen Carrier (LOHC) concept offers an efficient route to store hydrogen using organic compounds that are reversibly hydrogenated and dehydrogenated. One important challenge towards application of the LOHC technology at a larger scale is to minimize degradation of Pt-based dehydrogenation catalysts during long-term operation. Herein, we investigate the regeneration of Pt/alumina catalysts poisoned by LOHC degradation. We combine ultrahigh vacuum (UHV) studies on Pt(111), investigations on well-defined Pt/Al2O3 model catalysts, and near-ambient pressure (NAP) measurements on real core⿿shell Pt/Al2O3 catalyst pellets. The catalysts were purposely poisoned by reaction with the LOHC perhydro-dibenzyltoluene (H18-MSH) and with dicyclohexylmethane (DCHM) as a simpler model compound. We focus on oxidative regeneration under conditions that may be applied in real dehydrogenation reactors. The degree of poisoning and regeneration under oxidative reaction conditions was quantified using CO as a probe molecule and measured by infrared reflection-absorption spectroscopy (IRAS) and diffuse reflectance Fourier transform IR spectroscopy (DRIFTS) for planar model systems and real catalysts, respectively. We find that regeneration strongly depends on the composition of the catalyst surface. While the clean surface of a poisoned Pt(111) single crystal is fully restored upon thermal treatment in oxygen up to 700 K, contaminated Pt/Al2O3 model catalyst and core⿿shell pellet were only partially restored under the applied reaction conditions. Whereas partial regeneration on facet-like sites on supported catalysts is more facile than on Pt(111), carbonaceous deposits adsorbed at low-coordinated defect sites impede full regeneration of the Pt/Al2O3 catalysts.

  4. Disregarding Graduated Treatment: Why Transfer Aggravates Recidivism

    ERIC Educational Resources Information Center

    Johnson, Kristin; Lanza-Kaduce, Lonn; Woolard, Jennifer

    2011-01-01

    These data merge correctional histories with official state and courthouse information for a sample of teenage offenders, some of whom had been transferred to the adult system. Previous research indicated that transfer aggravates recidivism after the age of 18. The correctional data allow the examination of the relationship between sanctions and…

  5. Heat Transfer in High-Temperature Fibrous Insulation

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran

    2002-01-01

    The combined radiation/conduction heat transfer in high-porosity, high-temperature fibrous insulations was investigated experimentally and numerically. The effective thermal conductivity of fibrous insulation samples was measured over the temperature range of 300-1300 K and environmental pressure range of 1.33 x 10(exp -5)-101.32 kPa. The fibrous insulation samples tested had nominal densities of 24, 48, and 72 kilograms per cubic meter and thicknesses of 13.3, 26.6 and 39.9 millimeters. Seven samples were tested such that the applied heat flux vector was aligned with local gravity vector to eliminate natural convection as a mode of heat transfer. Two samples were tested with reverse orientation to investigate natural convection effects. It was determined that for the fibrous insulation densities and thicknesses investigated no heat transfer takes place through natural convection. A finite volume numerical model was developed to solve the governing combined radiation and conduction heat transfer equations. Various methods of modeling the gas/solid conduction interaction in fibrous insulations were investigated. The radiation heat transfer was modeled using the modified two-flux approximation assuming anisotropic scattering and gray medium. A genetic-algorithm based parameter estimation technique was utilized with this model to determine the relevant radiative properties of the fibrous insulation over the temperature range of 300-1300 K. The parameter estimation was performed by least square minimization of the difference between measured and predicted values of effective thermal conductivity at a density of 24 kilograms per cubic meters and at nominal pressures of 1.33 x 10(exp -4) and 99.98 kPa. The numerical model was validated by comparison with steady-state effective thermal conductivity measurements at other densities and pressures. The numerical model was also validated by comparison with a transient thermal test simulating reentry aerodynamic heating

  6. Interfacial and Thin Film Chemistry in Electron Device Fabrication

    DTIC Science & Technology

    1990-11-20

    mounted on our UHV surface analysis system, and J. Forster and D. V. Podlesnik of the IBM General Technology Division. The following discussion...IBM (East Fishkill). The system being built consists of three chambers: one UHV analysis chamber, one UHV reaction chamber and one high pressure...system will be equipped with several surface analysis and cleaning techniques. Fourier transform infrared spectrometry will be used to do attenuated

  7. Passive air sampling theory for semivolatile organic compounds.

    PubMed

    Bartkow, Michael E; Booij, Kees; Kennedy, Karen E; Müller, Jochen F; Hawker, Darryl W

    2005-07-01

    The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K(SV)) when air-side resistance dominates and increase with K(SV) when sampler-side resistance dominates.

  8. Testate amoeba transfer function performance along localised hydrological gradients.

    PubMed

    Tsyganov, Andrey N; Mityaeva, Olga A; Mazei, Yuri A; Payne, Richard J

    2016-09-01

    Testate amoeba transfer functions are widely used for reconstruction of palaeo-hydrological regime in peatlands. However, the limitations of this approach have become apparent with increasing attention to validation and assessing sources of uncertainty. This paper investigates effects of peatland type and sampling depth on the performance of a transfer function using an independent test-set from four Sphagnum-dominated sites in European Russia (Penza Region). We focus on transfer function performance along localised hydrological gradients, which is a useful analogue for predictive ability through time. The performance of the transfer function with the independent test-set was generally weaker than for the leave-one-out or bootstrap cross-validations. However, the transfer function was robust for the reconstruction of relative changes in water-table depth, provided the presence of good modern analogues and overlap in water-table depth ranges. When applied to subsurface samples, the performance of the transfer function was reduced due to selective decomposition, the presence of deep-dwelling taxa or vertical transfer of shells. Our results stress the importance of thorough testing of transfer functions, and highlight the role of taphonomic processes in determining results. Further studies of stratification, taxonomy and taphonomy of testate amoebae will be needed to improve the robustness of transfer function output. Copyright © 2015 Elsevier GmbH. All rights reserved.

  9. Gas sampling system for a mass spectrometer

    DOEpatents

    Taylor, Charles E; Ladner, Edward P

    2003-12-30

    The present invention relates generally to a gas sampling system, and specifically to a gas sampling system for transporting a hazardous process gas to a remotely located mass spectrometer. The gas sampling system includes a capillary tube having a predetermined capillary length and capillary diameter in communication with the supply of process gas and the mass spectrometer, a flexible tube surrounding and coaxial with the capillary tube intermediate the supply of process gas and the mass spectrometer, a heat transfer tube surrounding and coaxial with the capillary tube, and a heating device in communication the heat transfer tube for substantially preventing condensation of the process gas within the capillary tube.

  10. A sampling device with a capped body and detachable handle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jezek, Gerd-Rainer

    1997-12-01

    The present invention relates to a device for sampling radioactive waste and more particularly to a device for sampling radioactive waste which prevents contamination of a sampled material and the environment surrounding the sampled material. During vitrification of nuclear wastes, it is necessary to remove contamination from the surfaces of canisters filled with radioactive glass. After removal of contamination, a sampling device is used to test the surface of the canister. The one piece sampling device currently in use creates a potential for spreading contamination during vitrification operations. During operations, the one piece sampling device is transferred into and outmore » of the vitrification cell through a transfer drawer. Inside the cell, a remote control device handles the sampling device to wipe the surface of the canister. A one piece sampling device can be contaminated by the remote control device prior to use. Further, the sample device can also contaminate the transfer drawer producing false readings for radioactive material. The present invention overcomes this problem by enclosing the sampling pad in a cap. The removable handle is reused which reduces the amount of waste material.« less

  11. Swipe transfer assembly

    DOEpatents

    Christiansen, Robert M.; Mills, William C.

    1992-01-01

    The swipe transfer assembly is a mechanical assembly which is used in conjunction with glove boxes and other sealed containments. It is used to pass small samples into or out of glove boxes without an open breach of the containment, and includes a rotational cylinder inside a fixed cylinder, the inside cylinder being rotatable through an arc of approximately 240.degree. relative to the outer cylinder. An offset of 120.degree. from end to end allows only one port to be opened at a time. The assembly is made of stainless steel or aluminum and clear acrylic plastic to enable visual observation. The assembly allows transfer of swipes and smears from radiological and other specially controlled environments.

  12. Tracking the Transfers: State Policy and Practice.

    ERIC Educational Resources Information Center

    Cohen, Arthur M.

    1992-01-01

    In an effort to standardize the definition of the two-year college student transfer rate and to collect national transfer data, the Center for the Study of Community Colleges (CSCC) has solicited data annually since 1989 from a sample of 240 public and private two-year colleges nationwide. The CSCC has standardized the definition of "transfer…

  13. Medicaid and family wealth transfer.

    PubMed

    Lee, Jinkook; Kim, Hyungsoo; Tanenbaum, Sandra

    2006-02-01

    This study examines whether the relationship between making familial wealth transfers and becoming a Medicaid recipient sheds light on the current debate about Medicaid estate planning, whereby some elders transfer their assets to their families to qualify for Medicaid. Using the Health and Retirement Study, we tracked a national sample of community-based elders who did not receive Medicaid at the 1993 baseline interview but became Medicaid recipients during a 10-year time period and examined wealth transfers for these new Medicaid beneficiaries. Among elders aged 70 or older who did not receive Medicaid in 1993, 16.4% became Medicaid recipients over 10 years. Among these new Medicaid recipients, 17.9% transferred their wealth to family members before receiving Medicaid benefits, with an average transfer amount of $8,507 during the 2 years prior to receiving Medicaid benefits. In addition, 15.2% of community-residing elders entered a nursing home during the 10-year period, and 26.3% of these were covered by Medicaid. Of these new Medicaid recipients living in nursing homes, 12.6% transferred wealth to their families in the mean amount of $4,112. Familial wealth transfers do occur before changes in Medicaid eligibility in a small, but nontrivial, number of cases, but the amount transferred is modest, especially among nursing home residents. This finding implies that policies to reduce Medicaid long-term-care expenditures by limiting such transfers may not be very effective.

  14. Study of sample drilling techniques for Mars sample return missions

    NASA Technical Reports Server (NTRS)

    Mitchell, D. C.; Harris, P. T.

    1980-01-01

    To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.

  15. CANISTER TRANSFER SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B. Gorpani

    2000-06-23

    The Canister Transfer System receives transportation casks containing large and small disposable canisters, unloads the canisters from the casks, stores the canisters as required, loads them into disposal containers (DCs), and prepares the empty casks for re-shipment. Cask unloading begins with cask inspection, sampling, and lid bolt removal operations. The cask lids are removed and the canisters are unloaded. Small canisters are loaded directly into a DC, or are stored until enough canisters are available to fill a DC. Large canisters are loaded directly into a DC. Transportation casks and related components are decontaminated as required, and empty casks aremore » prepared for re-shipment. One independent, remotely operated canister transfer line is provided in the Waste Handling Building System. The canister transfer line consists of a Cask Transport System, Cask Preparation System, Canister Handling System, Disposal Container Transport System, an off-normal canister handling cell with a transfer tunnel connecting the two cells, and Control and Tracking System. The Canister Transfer System operating sequence begins with moving transportation casks to the cask preparation area with the Cask Transport System. The Cask Preparation System prepares the cask for unloading and consists of cask preparation manipulator, cask inspection and sampling equipment, and decontamination equipment. The Canister Handling System unloads the canister(s) and places them into a DC. Handling equipment consists of a bridge crane hoist, DC loading manipulator, lifting fixtures, and small canister staging racks. Once the cask has been unloaded, the Cask Preparation System decontaminates the cask exterior and returns it to the Carrier/Cask Handling System via the Cask Transport System. After the DC is fully loaded, the Disposal Container Transport System moves the DC to the Disposal Container Handling System for welding. To handle off-normal canisters, a separate off-normal canister

  16. Interhospital transfer of critically ill and injured children: an evaluation of transfer patterns, resource utilization, and clinical outcomes.

    PubMed

    Odetola, Folafoluwa O; Davis, Matthew M; Cohn, Lisa M; Clark, Sarah J

    2009-03-01

    To describe patterns of transfer, resource utilization, and clinical outcomes associated with interhospital transfer of critically ill and injured children. Secondary analysis of administrative claims data. Children 0 to 18 years in the Michigan Medicaid program who underwent interhospital transfer for intensive care from January 1, 2002 to December 31, 2004. The 3 sources of transfer from referring hospitals were: emergency department (ED), ward, or intensive care unit (ICU). Mortality and duration of hospital stay at the receiving hospitals. Of 1643 interhospital transfer admissions to intensive care at receiving hospitals, 62%, 31%, and 7% were from the ED, ward, and ICU of referring hospitals, respectively. Nineteen percent had comorbid illness, while 11% had organ dysfunction at the referring hospital. After controlling for comorbid illness, patient age, and pretransfer organ dysfunction; compared with ED transfers, mortality in the receiving hospital was higher for ward transfers (odds ratio [OR], 1.76; 95% confidence interval [CI], 1.02-3.03) but not for ICU transfers. Also, compared with ED transfers, hospital stay was longer by 1.5 days for ward transfers and by 13.5 days for ICU transfers. In this multiyear, statewide sample, mortality and resource utilization were higher among children who underwent interhospital transfer to intensive care after initial hospitalization, compared with those transferred directly from emergency to intensive care. Decision-making underlying initial triage and subsequent interhospital transfer of critically ill children warrants further study. (c) 2009 Society of Hospital Medicine.

  17. Transfer factors and effective half-lives of (134)Cs and (137)Cs in different environmental sample types obtained from Northern Finland: case Fukushima accident.

    PubMed

    Koivurova, Matias; Leppänen, Ari-Pekka; Kallio, Antti

    2015-08-01

    The Fukushima NPP accident caused a small but detectable cesium fallout in northern Finland, of the order of 1 Bq/m(2). This fallout transferred further to soil, water, flora and fauna. By using modern HPGe detector systems traces of (134)Cs from the Fukushima fallout were observed in various samples of biota. In northern Finland different types of environmental samples such as reindeer meat, berries, fish, lichens and wolf were collected during 2011-2013. The observed (134)Cs concentrations varied from 0.1 Bq/kg to a few Bq/kg. By using the known (134)Cs/(137)Cs ratio observed in Fukushima fallout the increase of the Fukushima accident to the (137)Cs concentrations was found to vary from 0.06 % to 6.9 % depending on the sample type. The aggregated transfer factors (Tag) and effective half-lives (Teff) for (134)Cs and (137)Cs were also determined and then compared with known values found from earlier studies which are calculated based on the fallout from the Chernobyl accident. Generally, the Tag and Teff values determined in this study were found to agree with the values found in the earlier studies. The Teff values were sample-type specific and were found to vary from 0.91 to 2.1 years for (134)Cs and the estimates for (137)Cs ranged between 1.6 and 19 years. Interestingly, the ground lichens had the longest Teff whereas the beard lichen had the shortest. In fauna, highest Tag values were determined for wolf meat ranging between 1.0 and 2.2 m(2)/kg. In flora, the highest Tag values were determined for beard lichens, ranging from 1.9 m(2)/kg to 3.5 m(2)/kg. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. TRANSFERENCE BEFORE TRANSFERENCE.

    PubMed

    Bonaminio, Vincenzo

    2017-10-01

    This paper is predominantly a clinical presentation that describes the transmigration of one patient's transference to another, with the analyst functioning as a sort of transponder. It involves an apparently accidental episode in which there was an unconscious intersection between two patients. The author's aim is to show how transference from one case may affect transference in another, a phenomenon the author calls transference before transference. The author believes that this idea may serve as a tool for understanding the unconscious work that takes place in the clinical situation. In a clinical example, the analyst finds himself caught up in an enactment involving two patients in which he becomes the medium of what happens in session. © 2017 The Psychoanalytic Quarterly, Inc.

  19. MELFI / GLACIER Transfers

    NASA Image and Video Library

    2013-03-12

    ISS034-E-067263 (12 March 2013) --- Canadian astronaut Chris Hadfield, right, assists fellow Expedition 34 flight engineer and NASA astronaut Tom Marshburn during Minus Eighty-Degree Laboratory Freezer for International Space Station (MELFI)operations. The two are doing transfers of samples connected to the General Laboratory Active Cryogenic ISS Experiment Refrigerator or GLACIER in the U.S. lab Destiny.

  20. Function Transfer in Human Operant Experiments: The Role of Stimulus Pairings

    ERIC Educational Resources Information Center

    Tonneau, Francois; Gonzalez, Carmen

    2004-01-01

    Although function transfer often has been studied in complex operant procedures (such as matching to sample), whether operant reinforcement actually produces function transfer in such settings has not been established. The present experiments, with high school students as subjects, suggest that stimulus pairings can promote function transfer in…

  1. Sample Handling in Extreme Environments

    NASA Technical Reports Server (NTRS)

    Avellar, Louisa; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph

    2013-01-01

    Harsh environments, such as that on Venus, preclude the use of existing equipment for functions that involve interaction with the environment. The operating limitations of current high temperature electronics are well below the actual temperature and pressure found on Venus (460 deg C and 92 atm), so proposed lander configurations typically include a pressure vessel where the science instruments are kept at Earth-like temperature and pressure (25 deg C and 1 atm). The purpose of this project was to develop and demonstrate a method for sample transfer from an external drill to internal science instruments for a lander on Venus. The initial concepts were string and pneumatically driven systems; and the latter system was selected for its ability to deliver samples at very high speed. The pneumatic system was conceived to be driven by the pressure difference between the Venusian atmosphere and the inside of the lander. The pneumatic transfer of a small capsule was demonstrated, and velocity data was collected from the lab experiment. The sample transfer system was modeled using CAD software and prototyped using 3D printing. General structural and thermal analyses were performed to approximate the proposed system's mass and effects on the temperature and pressure inside of the lander. Additionally, a sampler breadboard for use on Titan was tested and functionality problems were resolved.

  2. A Model of the Antecedents of Training Transfer

    ERIC Educational Resources Information Center

    Mohammed Turab, Ghaneemah; Casimir, Gian

    2015-01-01

    Many organizations have invested heavily in training. However, only a small percentage of what is learnt from training is applied or transferred to the workplace. This study examines factors that influence training transfer. A conceptual model based on the Theory of Reasoned Action is hypothesized and tested. The sample consisted of 123 full-time…

  3. Highly precise and compact ultrahigh vacuum rotary feedthrough.

    PubMed

    Aiura, Y; Kitano, K

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  4. Highly precise and compact ultrahigh vacuum rotary feedthrough

    NASA Astrophysics Data System (ADS)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  5. A Study of Best Practices in Training Transfer and Proposed Model of Transfer

    ERIC Educational Resources Information Center

    Burke, Lisa A.; Hutchins, Holly M.

    2008-01-01

    Data were gathered from a sample of training professionals of an American Society of Training and Development (ASTD) chapter in the southern United States regarding best practices for supporting training transfer. Content analysis techniques, based on a rigorous methodology proposed by Insch, Moore, & Murphy (1997), were used to analyze the…

  6. 7 CFR 27.73 - Supervision of transfers of cotton.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Supervision of transfers of cotton. 27.73 Section 27... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Postponed Classification § 27.73 Supervision of transfers of cotton. Whenever the owner of any cotton inspected and sampled for...

  7. 7 CFR 27.73 - Supervision of transfers of cotton.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Supervision of transfers of cotton. 27.73 Section 27... REGULATIONS COTTON CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Postponed Classification § 27.73 Supervision of transfers of cotton. Whenever the owner of any cotton inspected and sampled for...

  8. A cryogen-free low temperature scanning tunneling microscope capable of inelastic electron tunneling spectroscopy.

    PubMed

    Zhang, Shuai; Huang, Di; Wu, Shiwei

    2016-06-01

    The design and performance of a cryogen-free low temperature scanning tunneling microscope (STM) housed in ultrahigh vacuum (UHV) are reported. The cryogen-free design was done by directly integrating a Gifford-McMahon cycle cryocooler to a Besocke-type STM, and the vibration isolation was achieved by using a two-stage rubber bellow between the cryocooler and a UHV-STM interface with helium exchange gas cooling. A base temperature of 15 K at the STM was achieved, with a possibility to further decrease by using a cryocooler with higher cooling power and adding additional low temperature stage under the exchange gas interface. Atomically sharp STM images and high resolution dI/dV spectra on various samples were demonstrated. Furthermore, we reported the inelastic tunneling spectroscopy on a single carbon monoxide molecule adsorbed on Ag(110) surface with a cryogen-free STM for the first time. Being totally cryogen-free, the system not only saves the running cost significantly but also enables uninterrupted data acquisitions and variable temperature measurements with much ease. In addition, the system is capable of coupling light to the STM junction by a pair of lens inside the UHV chamber. We expect that these enhanced capabilities could further broaden our views to the atomic-scale world.

  9. The Acquisition and Transfer of Botanical Classification by Elementary Science Methods Students.

    ERIC Educational Resources Information Center

    Knapp, Clifford Edward

    Investigated were two questions related to the acquisition and transfer of botanical classification skill by elementary science methods students. Data were collected from a sample of 89 students enrolled in methods courses. Sixty-two students served as the experimental sample, and 27 served as the control for the transfer portion of the research.…

  10. RTE: A UNIX library with on-line documentation and sample programs for microwave radiative transfer calculations

    NASA Astrophysics Data System (ADS)

    Reynolds, J. C.; Schroeder, J. A.

    1993-03-01

    The FORTRAN library that the NOAA Wave Propagation Laboratory (WPL) developed to perform radiative transfer calculations for an upward-looking microwave radiometer is described. Although the theory and algorithms have been used for many years in WPL radiometer research, the Radiative Transfer Equation (RTE) software has combined them into a toolbox that is portable, readable, application independent, and easy to update. RTE has been optimized for the UNIX environment. However, the FORTRAN source code can be compiled on any platform that provides a Standard FORTRAN 77 compiler. RTE allows a user to do cloud modeling, calibrate radiometers, simulate hypothetical radiometer systems, develop retrieval techniques, and compute weighting functions. The radiative transfer model used is valid for channel frequencies below 1000 GHz in clear conditions and for frequencies below 100 GHz when clouds are present.

  11. Optimizing Frozen Sample Preparation for Laser Microdissection: Assessment of CryoJane Tape-Transfer System®

    PubMed Central

    Golubeva, Yelena G.; Smith, Roberta M.; Sternberg, Lawrence R.

    2013-01-01

    Laser microdissection is an invaluable tool in medical research that facilitates collecting specific cell populations for molecular analysis. Diversity of research targets (e.g., cancerous and precancerous lesions in clinical and animal research, cell pellets, rodent embryos, etc.) and varied scientific objectives, however, present challenges toward establishing standard laser microdissection protocols. Sample preparation is crucial for quality RNA, DNA and protein retrieval, where it often determines the feasibility of a laser microdissection project. The majority of microdissection studies in clinical and animal model research are conducted on frozen tissues containing native nucleic acids, unmodified by fixation. However, the variable morphological quality of frozen sections from tissues containing fat, collagen or delicate cell structures can limit or prevent successful harvest of the desired cell population via laser dissection. The CryoJane Tape-Transfer System®, a commercial device that improves cryosectioning outcomes on glass slides has been reported superior for slide preparation and isolation of high quality osteocyte RNA (frozen bone) during laser dissection. Considering the reported advantages of CryoJane for laser dissection on glass slides, we asked whether the system could also work with the plastic membrane slides used by UV laser based microdissection instruments, as these are better suited for collection of larger target areas. In an attempt to optimize laser microdissection slide preparation for tissues of different RNA stability and cryosectioning difficulty, we evaluated the CryoJane system for use with both glass (laser capture microdissection) and membrane (laser cutting microdissection) slides. We have established a sample preparation protocol for glass and membrane slides including manual coating of membrane slides with CryoJane solutions, cryosectioning, slide staining and dissection procedure, lysis and RNA extraction that facilitated

  12. Maternal transfer of mercury to songbird eggs.

    PubMed

    Ackerman, Joshua T; Hartman, C Alex; Herzog, Mark P

    2017-11-01

    We evaluated the maternal transfer of mercury to eggs in songbirds, determined whether this relationship differed between songbird species, and developed equations for predicting mercury concentrations in eggs from maternal blood. We sampled blood and feathers from 44 house wren (Troglodytes aedon) and 34 tree swallow (Tachycineta bicolor) mothers and collected their full clutches (n = 476 eggs) within 3 days of clutch completion. Additionally, we sampled blood and feathers from 53 tree swallow mothers and randomly collected one egg from their clutches (n = 53 eggs) during mid to late incubation (6-10 days incubated) to evaluate whether the relationship varied with the timing of sampling the mother's blood. Mercury concentrations in eggs were positively correlated with mercury concentrations in maternal blood sampled at (1) the time of clutch completion for both house wrens (R 2  = 0.97) and tree swallows (R 2  = 0.97) and (2) during mid to late incubation for tree swallows (R 2  = 0.71). The relationship between mercury concentrations in eggs and maternal blood did not differ with the stage of incubation when maternal blood was sampled. Importantly, the proportion of mercury transferred from mothers to their eggs decreased substantially with increasing blood mercury concentrations in tree swallows, but increased slightly with increasing blood mercury concentrations in house wrens. Additionally, the proportion of mercury transferred to eggs at the same maternal blood mercury concentration differed between species. Specifically, tree swallow mothers transferred 17%-107% more mercury to their eggs than house wren mothers over the observed mercury concentrations in maternal blood (0.15-1.92 μg/g ww). In contrast, mercury concentrations in eggs were not correlated with those in maternal feathers and, likewise, mercury concentrations in maternal blood were not correlated with those in feathers (all R 2  < 0.01). We provide equations to translate mercury

  13. Maternal transfer of mercury to songbird eggs

    USGS Publications Warehouse

    Ackerman, Joshua T.; Hartman, C. Alex; Herzog, Mark

    2017-01-01

    We evaluated the maternal transfer of mercury to eggs in songbirds, determined whether this relationship differed between songbird species, and developed equations for predicting mercury concentrations in eggs from maternal blood. We sampled blood and feathers from 44 house wren (Troglodytes aedon) and 34 tree swallow (Tachycineta bicolor) mothers and collected their full clutches (n = 476 eggs) within 3 days of clutch completion. Additionally, we sampled blood and feathers from 53 tree swallow mothers and randomly collected one egg from their clutches (n = 53 eggs) during mid to late incubation (6–10 days incubated) to evaluate whether the relationship varied with the timing of sampling the mother's blood. Mercury concentrations in eggs were positively correlated with mercury concentrations in maternal blood sampled at (1) the time of clutch completion for both house wrens (R2 = 0.97) and tree swallows (R2 = 0.97) and (2) during mid to late incubation for tree swallows (R2 = 0.71). The relationship between mercury concentrations in eggs and maternal blood did not differ with the stage of incubation when maternal blood was sampled. Importantly, the proportion of mercury transferred from mothers to their eggs decreased substantially with increasing blood mercury concentrations in tree swallows, but increased slightly with increasing blood mercury concentrations in house wrens. Additionally, the proportion of mercury transferred to eggs at the same maternal blood mercury concentration differed between species. Specifically, tree swallow mothers transferred 17%–107% more mercury to their eggs than house wren mothers over the observed mercury concentrations in maternal blood (0.15–1.92 μg/g ww). In contrast, mercury concentrations in eggs were not correlated with those in maternal feathers and, likewise, mercury concentrations in maternal blood were not correlated with those in feathers (all R2 < 0.01). We provide equations to translate mercury

  14. Drop transfer between superhydrophobic wells using air logic control.

    PubMed

    Vuong, Thach; Cheong, Brandon Huey-Ping; Huynh, So Hung; Muradoglu, Murat; Liew, Oi Wah; Ng, Tuck Wah

    2015-02-21

    Superhydrophobic surfaces aid biochemical analysis by limiting sample loss. A system based on wells here tolerated tilting up to 20° and allowed air logic transfer with evidence of mixing. Conditions for intact transfer on 15 to 60 μL drops using compressed air pressure operation were also mapped.

  15. Odorant transfer characteristics of white bread during baking.

    PubMed

    Onishi, Masanobu; Inoue, Michiko; Araki, Tetsuya; Iwabuchi, Hisakatsu; Sagara, Yasuyuki

    2011-01-01

    The potent odorants in the crust and crumb of white bread were identified and quantified by gas chromatography-mass spectrometry and gas chromatography/olfactometry. The weight loss ratio of the samples baked at 220 °C was controlled in the range of 0-28%. The odorants were classified into 5 types by the transfer characteristics: i) All amounts of odorant transferred from the crust to external space (type-I). ii) All transferred from the crust to the crumb and external space (type-II). iii) Certain amount remaining in the crust and the rest transferred to the crumb and external space (type-III). iv) All transferred from the crumb to external space (type-IV). v) Certain amount remaining in the crumb and the rest transferred to the crust and external space (type-V). The odorants of type-IV were not apparent after the crust had formed. The results indicate that the crust could be a barrier to prevent the odorants from being transferred to external space.

  16. Supporting Students' Knowledge Transfer in Modeling Activities

    ERIC Educational Resources Information Center

    Piksööt, Jaanika; Sarapuu, Tago

    2014-01-01

    This study investigates ways to enhance secondary school students' knowledge transfer in complex science domains by implementing question prompts. Two samples of students applied two web-based models to study molecular genetics--the model of genetic code (n = 258) and translation (n = 245). For each model, the samples were randomly divided into…

  17. Microscale surface modifications for heat transfer enhancement.

    PubMed

    Bostanci, Huseyin; Singh, Virendra; Kizito, John P; Rini, Daniel P; Seal, Sudipta; Chow, Louis C

    2013-10-09

    In this experimental study, two surface modification techniques were investigated for their effect on heat transfer enhancement. One of the methods employed the particle (grit) blasting to create microscale indentations, while the other used plasma spray coating to create microscale protrusions on Al 6061 (aluminum alloy 6061) samples. The test surfaces were characterized using scanning electron microscopy (SEM) and confocal scanning laser microscopy. Because of the surface modifications, the actual surface area was increased up to 2.8× compared to the projected base area, and the arithmetic mean roughness value (Ra) was determined to vary from 0.3 μm for the reference smooth surface to 19.5 μm for the modified surfaces. Selected samples with modified surfaces along with the reference smooth surface were then evaluated for their heat transfer performance in spray cooling tests. The cooling system had vapor-atomizing nozzles and used anhydrous ammonia as the coolant in order to achieve heat fluxes up to 500 W/cm(2) representing a thermal management setting for high power systems. Experimental results showed that the microscale surface modifications enhanced heat transfer coefficients up to 76% at 500 W/cm(2) compared to the smooth surface and demonstrated the benefits of these practical surface modification techniques to enhance two-phase heat transfer process.

  18. Collecting cometary soil samples? Development of the ROSETTA sample acquisition system

    NASA Technical Reports Server (NTRS)

    Coste, P. A.; Fenzi, M.; Eiden, Michael

    1993-01-01

    In the reference scenario of the ROSETTA CNRS mission, the Sample Acquisition System is mounted on the Comet Lander. Its tasks are to acquire three kinds of cometary samples and to transfer them to the Earth Return Capsule. Operations are to be performed in vacuum and microgravity, on a probably rough and dusty surface, in a largely unknown material, at temperatures in the order of 100 K. The concept and operation of the Sample Acquisition System are presented. The design of the prototype corer and surface sampling tool, and of the equipment for testing them at cryogenic temperatures in ambient conditions and in vacuum in various materials representing cometary soil, are described. Results of recent preliminary tests performed in low temperature thermal vacuum in a cometary analog ice-dust mixture are provided.

  19. Results from tests of TFL Hydragard sampling loop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steimke, J.L.

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard{reg_sign} sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the originalmore » Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause.« less

  20. Biomedical technology transfer applications of NASA science and technology

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The identification and solution of research and clinical problems in cardiovascular medicine which were investigated by means of biomedical data transfer are reported. The following are sample areas that were focused upon by the Stanford University Biomedical Technology Transfer Team: electrodes for hemiplegia research; vectorcardiogram computer analysis; respiration and phonation electrodes; radiotelemetry of intracranial pressure; and audiotransformation of the electrocardiographic signal. It is concluded that this biomedical technology transfer is significantly aiding present research in cardiovascular medicine.

  1. Preparation of magnetic molecularly imprinted polymers by atom transfer radical polymerization for the rapid extraction of avermectin from fish samples.

    PubMed

    You, Xiaoxiao; Gao, Lei; Qin, Dongli; Chen, Ligang

    2017-01-01

    A novel and highly efficient approach to obtain magnetic molecularly imprinted polymers is described to detect avermectin in fish samples. The magnetic molecularly imprinted polymers were synthesized by surface imprinting polymerization using magnetic multiwalled carbon nanotubes as the support materials, atom transfer radical polymerization as the polymerization method, avermectin as template, acrylamide as functional monomer, and ethylene glycol dimethacrylate as crosslinker. The characteristics of the magnetic molecularly imprinted polymers were assessed by using transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, vibrating sample magnetometry, X-ray diffraction, and thermogravimetric analysis. The binding characteristics of magnetic molecularly imprinted polymers were researched through isothermal adsorption experiment, kinetics adsorption experiment, and the selectivity experiment. Coupled with ultra high performance liquid chromatography and tandem mass spectrometry, the extraction conditions of the magnetic molecularly imprinted polymers as adsorbents for avermectin were investigated in detail. The recovery of avermectin was 84.2-97.0%, and the limit of detection was 0.075 μg/kg. Relative standard deviations of intra- and inter-day precisions were in the range of 1.7-2.9% and 3.4-5.6%, respectively. The results demonstrated that the extraction method not only has high selectivity and accuracy, but also is convenient for the determination of avermectin in fish samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. IP Sample Plan #5 | NCI Technology Transfer Center | TTC

    Cancer.gov

    A sample Intellectual Property Management Plan in the form of a legal agreement between a University and its collaborators which addresses data sharing, sharing of research tools and resources and intellectual property management.

  3. Phobos/Deimos Sample Return via Solar Sail

    NASA Technical Reports Server (NTRS)

    Matloff, Gregory L.; Taylor, Travis; Powell, Conley; Moton, Tryshanda

    2004-01-01

    Abstract A sample-return mission to the martian satellites using a contemporary solar sail for all post-Earth-escape propulsion is proposed. The 0.015 kg/sq m areal mass-thickness sail unfurls after launch and injection onto a Mars-bound Hohmann-transfer ellipse. Structure and pay!oad increase spacecraft areal mass thickness to 0.028 kg/sq m. During Mars-encounter, the sail functions parachute-like in Mars s outer atmosphere to accomplish aerocapture. On-board thrusters or the sail maneuver the spacecraft into an orbit with periapsis near Mars and apoapsis near Phobos. The orbit is circularized for Phobos-rendezvous; surface samples are collected. The sail then raises the orbit for Deimos-rendezvous and sample collection. The sail next places the spacecraft on an Earth-bound Hohmann-transfer ellipse. During Earth-encounter, the sail accomplishes Earth-aerocapture or partially decelerates the sample container for entry into Earth s atmosphere. Mission mass budget is about 218 grams and; mission duration is <5 years.

  4. A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lubeck, J., E-mail: janin.lubeck@ptb.de; Fliegauf, R.; Holfelder, I.

    A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors suchmore » as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.« less

  5. Electrostatic transfer of epitaxial graphene to glass.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, Taisuke; Pan, Wei; Howell, Stephen Wayne

    2010-12-01

    We report on a scalable electrostatic process to transfer epitaxial graphene to arbitrary glass substrates, including Pyrex and Zerodur. This transfer process could enable wafer-level integration of graphene with structured and electronically-active substrates such as MEMS and CMOS. We will describe the electrostatic transfer method and will compare the properties of the transferred graphene with nominally-equivalent 'as-grown' epitaxial graphene on SiC. The electronic properties of the graphene will be measured using magnetoresistive, four-probe, and graphene field effect transistor geometries [1]. To begin, high-quality epitaxial graphene (mobility 14,000 cm2/Vs and domains >100 {micro}m2) is grown on SiC in an argon-mediated environmentmore » [2,3]. The electrostatic transfer then takes place through the application of a large electric field between the donor graphene sample (anode) and the heated acceptor glass substrate (cathode). Using this electrostatic technique, both patterned few-layer graphene from SiC(000-1) and chip-scale monolayer graphene from SiC(0001) are transferred to Pyrex and Zerodur substrates. Subsequent examination of the transferred graphene by Raman spectroscopy confirms that the graphene can be transferred without inducing defects. Furthermore, the strain inherent in epitaxial graphene on SiC(0001) is found to be partially relaxed after the transfer to the glass substrates.« less

  6. Investigating the Efficacy of Web-Based Transfer Training on Independent Wheelchair Transfers Through Randomized Controlled Trials.

    PubMed

    Worobey, Lynn A; Rigot, Stephanie K; Hogaboom, Nathan S; Venus, Chris; Boninger, Michael L

    2018-01-01

    To determine the efficacy of a web-based transfer training module at improving transfer technique across 3 groups: web-based training, in-person training (current standard of practice), and a waitlist control group (WLCG); and secondarily, to determine subject factors that can be used to predict improvements in transfer ability after training. Randomized controlled trials. Summer and winter sporting events for disabled veterans. A convenience sample (N=71) of manual and power wheelchair users who could transfer independently. An individualized, in-person transfer training session or a web-based transfer training module. The WLCG received the web training at their follow-up visit. Transfer Assessment Instrument (TAI) part 1 score was used to assess transfers at baseline, skill acquisition immediately posttraining, and skill retention after a 1- to 2-day follow-up period. The in-person and web-based training groups improved their median (interquartile range) TAI scores from 7.98 (7.18-8.46) to 9.13 (8.57-9.58; P<.01), and from 7.14 (6.15-7.86) to 9.23 (8.46-9.82; P<.01), respectively, compared with the WLCG that had a median score of 7.69 for both assessments (baseline, 6.15-8.46; follow-up control, 5.83-8.46). Participants retained improvements at follow-up (P>.05). A lower initial TAI score was found to be the only significant predictor of a larger percent change in TAI score after receiving training. Transfer training can improve technique with changes retained within a short follow-up window, even among experienced wheelchair users. Web-based transfer training demonstrated comparable improvements to in-person training. With almost half of the United States population consulting online resources before a health care professional, web-based training may be an effective method to increase knowledge translation. Copyright © 2017 American Congress of Rehabilitation Medicine. All rights reserved.

  7. An apparatus for preparing benthic samples aboard ship

    USGS Publications Warehouse

    Pepper, Phillip N.; Girard, Thomas L.; Stapanian, Martin A.

    2001-01-01

    We describe a safe and effective apparatus for washing and reducing the volume of benthic samples collected by grab samplers aboard ship. The sample is transferred directly from the dredge to the apparatus and then washed with water pumped through pipes in the apparatus and from onboard hoses. Wastewater and materials smaller than 0.541 mm in diameter are washed overboard. Larger materials, including benthic organisms, collect on an upper 0.64-cm screen and on a lower 30-mm-mesh stainless steel bolt cloth. A collection jar is screwed into the bottom of the apparatus. Therefore, transfer of sample material from the apparatus to the jar is quick and easy. This apparatus has several advantages for use aboard ship over others described in the literature, especially in rough seas, in cold weather, and at night. The apparatus provides a safe and convenient platform for washing and reducing samples, and samples can be prepared while the vessel is traveling at full speed.

  8. IP Sample Plan #1 | NCI Technology Transfer Center | TTC

    Cancer.gov

    Sample letter that shows how Universities including co-investigators, consultants, and collaborators can describe a data and research tool sharing plan and procedures for exercising intellectual property rights. The letter is to be used as part of the University's application. 

  9. Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

    NASA Technical Reports Server (NTRS)

    Leopold, Daniel J.

    2002-01-01

    The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

  10. The EMIL project at BESSY II: Beamline design and performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendel, Stefan, E-mail: stefan.hendel@helmholtz-berlin.de; Schäfers, Franz; Reichardt, Gerd

    2016-07-27

    The Energy Materials In-Situ Laboratory Berlin (EMIL) at BESSY-II is currently under construction. Two canted undulators for soft- and hard X-rays will be installed into the BESSY II storage ring in one straight section, complex beamlines with more than twenty optical elements will be set up and a new laboratory building attached to BESSY II will host three endstations and a large UHV-transfer system connecting various HV- and UHV-deposition systems. The undulators, UE48 and U17, provide a broad energy spectrum of 80 - 10000 eV, of which the harder radiation (>700 eV) is provided by a cryogenic in-vacuum device. Threemore » monochromators (two plane grating monochromators (PGM) and one LN{sub 2}-cooled double crystal monochromator (DCM)) disperse the radiation into separate pathways of 65 m length, while downstream of the monochromators split-mirror chambers distribute the photon beam to one (or simultaneously to two) of five upcoming endstations. Three of these endstations are designed for the full energy range with spatial overlap of the soft and hard foci, whereas one endstation (PEEM) uses only the soft and another one (PINK) only the hard branch, respectively.« less

  11. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    PubMed

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire; Bevan, Sarah; Turvill, James; Turnock, Daniel

    2018-01-01

    Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.

  12. IP Sample Plan #3 | NCI Technology Transfer Center | TTC

    Cancer.gov

    Sample Research Resources and Intellectual Property Plan for use by an Institution and its Collaborators for intellectual property protection strategies covering pre-existing intellectual property, agreements with commercial sources, privacy, and licensing.  | [google6f4cd5334ac394ab.html

  13. IP Sample Plan #4 | NCI Technology Transfer Center | TTC

    Cancer.gov

    Sample letter from Research Institutes and their principal investigator and consultants, describing a data and research tool sharing plan and procedures for sharing data, research materials, and patent and licensing of intellectual property. This letter is designed to be included as part of an application.

  14. A quick method based on SIMPLISMA-KPLS for simultaneously selecting outlier samples and informative samples for model standardization in near infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Li-Na; Ma, Chang-Ming; Chang, Ming; Zhang, Ren-Cheng

    2017-12-01

    A novel method based on SIMPLe-to-use Interactive Self-modeling Mixture Analysis (SIMPLISMA) and Kernel Partial Least Square (KPLS), named as SIMPLISMA-KPLS, is proposed in this paper for selection of outlier samples and informative samples simultaneously. It is a quick algorithm used to model standardization (or named as model transfer) in near infrared (NIR) spectroscopy. The NIR experiment data of the corn for analysis of the protein content is introduced to evaluate the proposed method. Piecewise direct standardization (PDS) is employed in model transfer. And the comparison of SIMPLISMA-PDS-KPLS and KS-PDS-KPLS is given in this research by discussion of the prediction accuracy of protein content and calculation speed of each algorithm. The conclusions include that SIMPLISMA-KPLS can be utilized as an alternative sample selection method for model transfer. Although it has similar accuracy to Kennard-Stone (KS), it is different from KS as it employs concentration information in selection program. This means that it ensures analyte information is involved in analysis, and the spectra (X) of the selected samples is interrelated with concentration (y). And it can be used for outlier sample elimination simultaneously by validation of calibration. According to the statistical data results of running time, it is clear that the sample selection process is more rapid when using KPLS. The quick algorithm of SIMPLISMA-KPLS is beneficial to improve the speed of online measurement using NIR spectroscopy.

  15. External and Institutional Factors Affecting Community College Student-Transfer Activity.

    ERIC Educational Resources Information Center

    Banks, Debra L.

    A study was conducted to identify the environmental conditions and relationships between external and institutional conditions that have a significant effect upon student transfer activity. A sample of 78 colleges in 15 states were selected from institutions participating in a national transfer project; 42% were located in Texas or California. The…

  16. Income Transfers and Maternal Health: Evidence from a National Randomized Social Cash Transfer Program in Zambia.

    PubMed

    Handa, Sudhanshu; Peterman, Amber; Seidenfeld, David; Tembo, Gelson

    2016-02-01

    There is promising recent evidence that poverty-targeted social cash transfers have potential to improve maternal health outcomes; however, questions remain surrounding design features responsible for impacts. In addition, virtually no evidence exists from the African region. This study explores the impact of Zambia's Child Grant Program on a range of maternal health utilization outcomes using a randomized design and difference-in-differences multivariate regression from data collected over 24 months from 2010 to 2012. Results indicate that while there are no measurable program impacts among the main sample, there are heterogeneous impacts on skilled attendance at birth among a sample of women residing in households having better access to maternal health services. The latter result is particularly interesting because of the overall low level of health care availability in program areas suggesting that dedicated program design or matching supply-side interventions may be necessary to leverage unconditional cash transfers in similar settings to impact maternal health. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Income transfers and maternal health: Evidence from a national randomized social cash transfer program in Zambia

    PubMed Central

    Handa, Sudhanshu; Peterman, Amber; Seidenfeld, David; Tembo, Gelson

    2017-01-01

    There is promising recent evidence that poverty-targeted social cash transfers have potential to improve maternal health outcomes, however questions remain surrounding design features responsible for impacts. In addition, virtually no evidence exists from the African region. This study explores the impact of Zambia’s Child Grant Program on a range of maternal health utilization outcomes using a randomized design and difference-in-differences multivariate regression from data collected over 24 months from 2010 to 2012. Results indicate that while there are no measurable program impacts among the main sample, there are heterogeneous impacts on skilled attendance at birth among a sample of women residing in households having better access to maternal health services. The latter result is particularly interesting because of the overall low level of healthcare availability in program areas suggesting dedicated program design or matching supply-side interventions may be necessary to leverage unconditional cash transfers in similar settings to impact maternal health. PMID:25581062

  18. Reference binding energies of transition metal carbides by core-level x-ray photoelectron spectroscopy free from Ar+ etching artefacts

    NASA Astrophysics Data System (ADS)

    Greczynski, G.; Primetzhofer, D.; Hultman, L.

    2018-04-01

    We report x-ray photoelectron spectroscopy (XPS) core level binding energies (BE's) for the widely-applicable groups IVb-VIb transition metal carbides (TMCs) TiC, VC, CrC, ZrC, NbC, MoC, HfC, TaC, and WC. Thin film samples are grown in the same deposition system, by dc magnetron co-sputtering from graphite and respective elemental metal targets in Ar atmosphere. To remove surface contaminations resulting from exposure to air during sample transfer from the growth chamber into the XPS system, layers are either (i) Ar+ ion-etched or (ii) UHV-annealed in situ prior to XPS analyses. High resolution XPS spectra reveal that even gentle etching affects the shape of core level signals, as well as BE values, which are systematically offset by 0.2-0.5 eV towards lower BE. These destructive effects of Ar+ ion etch become more pronounced with increasing the metal atom mass due to an increasing carbon-to-metal sputter yield ratio. Systematic analysis reveals that for each row in the periodic table (3d, 4d, and 5d) C 1s BE increases from left to right indicative of a decreased charge transfer from TM to C atoms, hence bond weakening. Moreover, C 1s BE decreases linearly with increasing carbide/metal melting point ratio. Spectra reported here, acquired from a consistent set of samples in the same instrument, should serve as a reference for true deconvolution of complex XPS cases, including multinary carbides, nitrides, and carbonitrides.

  19. Influence of Spacer Systems on Heat Transfer in Evacuated Glazing

    NASA Astrophysics Data System (ADS)

    Swimm, K.; Weinläder, H.; Ebert, H.-P.

    2009-06-01

    One attractive possibility to essentially improve the insulation properties of glazing is to evacuate the space between the glass panes. This eliminates heat transport due to convection between the glass panes and suppresses the thermal conductivity of the remaining low pressure filling gas atmosphere. The glass panes can be prevented from collapsing by using a matrix of spacers. These spacers, however, increase heat transfer between the glass panes. To quantify this effect, heat transfer through samples of evacuated glazing was experimentally determined. The samples were prepared with different kinds of spacer materials and spacer distances. The measurements were performed with a guarded hot-plate apparatus under steady-state conditions and at room temperature. The measuring chamber of the guarded hot plate was evacuated to < 10-2 Pa. An external pressure load of 0.1 MPa was applied on the samples to ensure realistic system conditions. Radiative heat transfer was significantly reduced by preparing the samples with a low- ɛ coating on one of the glass panes. In a first step, measurements without any spacers allowed quantification of the amount of radiative heat transfer. With these data, the measurements with spacers could be corrected to separate the effect of the spacers on thermal heat transfer. The influence of the thermal conductivity of the spacer material, as well as the distance between the spacers and the spacer geometry, was experimentally investigated and showed good agreement with simulation results. For mechanically stable matrices with cylindrical spacers, experimental thermal conductance values ≤0.44W·m-2 ·K-1 were found. This shows that U g -values of about 0.5W · m-2 · K-1 are achievable in evacuated glazing, if highly efficient low-emissivity coatings are used.

  20. A cryogen-free low temperature scanning tunneling microscope capable of inelastic electron tunneling spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Shuai; Huang, Di; Wu, Shiwei, E-mail: swwu@fudan.edu.cn

    The design and performance of a cryogen-free low temperature scanning tunneling microscope (STM) housed in ultrahigh vacuum (UHV) are reported. The cryogen-free design was done by directly integrating a Gifford-McMahon cycle cryocooler to a Besocke-type STM, and the vibration isolation was achieved by using a two-stage rubber bellow between the cryocooler and a UHV-STM interface with helium exchange gas cooling. A base temperature of 15 K at the STM was achieved, with a possibility to further decrease by using a cryocooler with higher cooling power and adding additional low temperature stage under the exchange gas interface. Atomically sharp STM imagesmore » and high resolution dI/dV spectra on various samples were demonstrated. Furthermore, we reported the inelastic tunneling spectroscopy on a single carbon monoxide molecule adsorbed on Ag(110) surface with a cryogen-free STM for the first time. Being totally cryogen-free, the system not only saves the running cost significantly but also enables uninterrupted data acquisitions and variable temperature measurements with much ease. In addition, the system is capable of coupling light to the STM junction by a pair of lens inside the UHV chamber. We expect that these enhanced capabilities could further broaden our views to the atomic-scale world.« less

  1. Large area scanning probe microscope in ultra-high vacuum demonstrated for electrostatic force measurements on high-voltage devices.

    PubMed

    Gysin, Urs; Glatzel, Thilo; Schmölzer, Thomas; Schöner, Adolf; Reshanov, Sergey; Bartolf, Holger; Meyer, Ernst

    2015-01-01

    The resolution in electrostatic force microscopy (EFM), a descendant of atomic force microscopy (AFM), has reached nanometre dimensions, necessary to investigate integrated circuits in modern electronic devices. However, the characterization of conducting or semiconducting power devices with EFM methods requires an accurate and reliable technique from the nanometre up to the micrometre scale. For high force sensitivity it is indispensable to operate the microscope under high to ultra-high vacuum (UHV) conditions to suppress viscous damping of the sensor. Furthermore, UHV environment allows for the analysis of clean surfaces under controlled environmental conditions. Because of these requirements we built a large area scanning probe microscope operating under UHV conditions at room temperature allowing to perform various electrical measurements, such as Kelvin probe force microscopy, scanning capacitance force microscopy, scanning spreading resistance microscopy, and also electrostatic force microscopy at higher harmonics. The instrument incorporates beside a standard beam deflection detection system a closed loop scanner with a scan range of 100 μm in lateral and 25 μm in vertical direction as well as an additional fibre optics. This enables the illumination of the tip-sample interface for optically excited measurements such as local surface photo voltage detection. We present Kelvin probe force microscopy (KPFM) measurements before and after sputtering of a copper alloy with chromium grains used as electrical contact surface in ultra-high power switches. In addition, we discuss KPFM measurements on cross sections of cleaved silicon carbide structures: a calibration layer sample and a power rectifier. To demonstrate the benefit of surface photo voltage measurements, we analysed the contact potential difference of a silicon carbide p/n-junction under illumination.

  2. Correlation between human maternal-fetal placental transfer and molecular weight of PCB and dioxin congeners/isomers.

    PubMed

    Mori, Chisato; Nakamura, Noriko; Todaka, Emiko; Fujisaki, Takeyoshi; Matsuno, Yoshiharu; Nakaoka, Hiroko; Hanazato, Masamichi

    2014-11-01

    Establishing methods for the assessment of fetal exposure to chemicals is important for the prevention or prediction of the child's future disease risk. In the present study, we aimed to determine the influence of molecular weight on the likelihood of chemical transfer from mother to fetus via the placenta. The correlation between molecular weight and placental transfer rates of congeners/isomers of polychlorinated biphenyls (PCBs) and dioxins was examined. Twenty-nine sample sets of maternal blood, umbilical cord, and umbilical cord blood were used to measure PCB concentration, and 41 sample sets were used to analyze dioxins. Placental transfer rates were calculated using the concentrations of PCBs, dioxins, and their congeners/isomers within these sample sets. Transfer rate correlated negatively with molecular weight for PCB congeners, normalized using wet and lipid weights. The transfer rates of PCB or dioxin congeners differed from those of total PCBs or dioxins. The transfer rate for dioxin congeners did not always correlate significantly with molecular weight, perhaps because of the small sample size or other factors. Further improvement of the analytical methods for dioxin congeners is required. The findings of the present study suggested that PCBs, dioxins, or their congeners with lower molecular weights are more likely to be transferred from mother to fetus via the placenta. Consideration of chemical molecular weight and transfer rate could therefore contribute to the assessment of fetal exposure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Carbon transfer from plant roots to soil - NanoSIMS analyses of undisturbed rhizosphere samples

    NASA Astrophysics Data System (ADS)

    Vidal, Alix; Hirte, Juliane; Bender, S. Franz; Mayer, Jochen; Gattinger, Andreas; Mueller, Carsten W.

    2017-04-01

    Soils are composed of a wide diversity of organic and mineral compounds, interacting to form complex mosaics of microenvironments. Roots and microorganisms are both key sources of organic carbon (OC). The volume of soil around living roots, i.e. the rhizosphere, is a privileged area for soil microbial activity and diversity. The microscopic observation of embedded soil sections has been applied since the 1950´s and has enabled observation of the rhizosphere at the smallest scale of organism interaction, i.e. at the level of root cells and bacteria (Alexander and Jackson, 1954). However, the observation of microorganisms in their intact environment, especially in soil, remains challenging. Existing microscopic images do not provide clear evidence of the chemical composition of compounds observed in the rhizosphere. Nano-scale secondary ion mass spectrometry (NanoSIMS) is a high spatial resolution method providing elemental and isotopic maps of organic and mineral materials. This technic has been increasingly used in soil science during the last decade (Hermann et al., 2007; Vogel et al., 2014) and more specifically for undisturbed soil sample observations (Vidal et al., 2016). In the present study, NanoSIMS was used to illustrate the biological, physical and chemical processes occurring in the rhizosphere at the microscale. To meet this objective, undisturbed rhizosphere samples were collected from a field experiment in Switzerland where wheat plants were pulse-labelled with 99% 13C-CO2 in weekly intervals throughout the growing season and sampled at flowering. Samples were embedded, sectioned, polished and analyzed with NanoSIMS, obtaining secondary ion images of 12C, 13C, 12C14N, 16O, 31P16O2, and 32S. The δ13C maps were obtained thanks to 12C and 13C images. 13C labelled root cells were clearly distinguished on images and presented highly variable δ13C values. Labelled spots (< 1 µm), identified as bacteria, were located at the root cell surroundings. These

  4. Comet sample acquisition for ROSETTA lander mission

    NASA Astrophysics Data System (ADS)

    Marchesi, M.; Campaci, R.; Magnani, P.; Mugnuolo, R.; Nista, A.; Olivier, A.; Re, E.

    2001-09-01

    ROSETTA/Lander is being developed with a combined effort of European countries, coordinated by German institutes. The commitment for such a challenging probe will provide a unique opportunity for in-situ analysis of a comet nucleus. The payload for coring, sampling and investigations of comet materials is called SD2 (Sampling Drilling and Distribution). The paper presents the drill/sampler tool and the sample transfer trough modeling, design and testing phases. Expected drilling parameters are then compared with experimental data; limited torque consumption and axial thrust on the tool constraint the operation and determine the success of tests. Qualification campaign involved the structural part and related vibration test, the auger/bit parts and drilling test, and the coring mechanism with related sampling test. Mechanical check of specimen volume is also reported, with emphasis on the measurement procedure and on the mechanical unit. The drill tool and all parts of the transfer chain were tested in the hypothetical comet environment, charcterized by frozen material at extreme low temperature and high vacuum (-160°C, 10-3 Pa).

  5. Phobos/Deimos sample return via solar sail.

    PubMed

    Matloff, Gregory L; Taylor, Travis; Powell, Conley; Moton, Tryshanda

    2005-12-01

    A sample-return mission to the Martian satellites using a con-temporary solar sail for all post-Earth-escape propulsion is proposed. The 0.015 kg/m(2) areal mass-thickness sail unfurls after launch and injection onto a Mars-bound Hohmann-transfer ellipse. Structure and payload increase spacecraft areal mass thickness to 0.028 kg/m(2). During the Mars encounter, the sail functions as a parachute in the outer atmosphere of Mars to accomplish aerocapture. On-board thrusters or the sail maneuver the spacecraft into an orbit with periapsis near Mars and apoapsis near Phobos. The orbit is circularized for Phobos-rendezvous; surface samples are collected. The sail then raises the orbit for Deimos-rendezvous and sample collection. The sail next places the spacecraft on an Earth-bound Hohmann-transfer ellipse. During Earth encounter, the sail accomplishes Earth-aerocapture or partially decelerates the sample container for entry into the Earth's atmosphere. Mission mass budget is about 218 grams and mission duration is less than five years.

  6. A new passive system for contamination-free long-distance cryo-transfer of biological tissues

    NASA Astrophysics Data System (ADS)

    Cheng, Tian; Plane, Florent; Søgaard Jensen, Louise Helene; van den Brandt, Ben; Comment, Arnaud; Meibom, Anders

    2017-12-01

    Several new analytical techniques require long-distance cryogenic transfer of samples that need to be kept at stable temperatures for long time periods, but also to be additionally contamination-free. In this study we developed a passive transfer system to fulfil those requirements. With 125mL of liquid nitrogen stored, one cryo-sectioned sample was maintained around 120±1 K and a pressure of about 3x10-7 mbar for at least 2 hours. With a total transfer weight of 5 Kg this system can be easily handled and carried by any transportation means so that the same sample can be used for different imaging centres located remotely permitting correlative studies.

  7. Geoelectrical inference of mass transfer parameters using temporal moments

    USGS Publications Warehouse

    Day-Lewis, Frederick D.; Singha, Kamini

    2008-01-01

    We present an approach to infer mass transfer parameters based on (1) an analytical model that relates the temporal moments of mobile and bulk concentration and (2) a bicontinuum modification to Archie's law. Whereas conventional geochemical measurements preferentially sample from the mobile domain, electrical resistivity tomography (ERT) is sensitive to bulk electrical conductivity and, thus, electrolytic solute in both the mobile and immobile domains. We demonstrate the new approach, in which temporal moments of collocated mobile domain conductivity (i.e., conventional sampling) and ERT‐estimated bulk conductivity are used to calculate heterogeneous mass transfer rate and immobile porosity fractions in a series of numerical column experiments.

  8. Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: a modular vacuum ultraviolet source.

    PubMed

    Roberts, F Sloan; Anderson, Scott L

    2013-12-01

    The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a "soft" photoionization source for gas-phase mass spectrometry.

  9. Effects of select and reject control on equivalence class formation and transfer of function.

    PubMed

    Perez, William F; Tomanari, Gerson Y; Vaidya, Manish

    2015-09-01

    The present study used a single-subject design to evaluate the effects of select or reject control on equivalence class formation and transfer of function. Adults were exposed to a matching-to-sample task with observing requirements (MTS-OR) in order to bias the establishment of sample/S+ (select) or sample/S- (reject) relations. In Experiment 1, four sets of baseline conditional relations were taught-two under reject control (A1B2C1, A2B1C2) and two under select control (D1E1F1, D2E2F2). Participants were tested for transitivity, symmetry, equivalence and reflexivity. They also learned a simple discrimination involving one of the stimuli from the equivalence classes and were tested for the transfer of the discriminative function. In general, participants performed with high accuracy on all equivalence-related probes as well as the transfer of function probes under select control. Under reject control, participants had high scores only on the symmetry test; transfer of function was attributed to stimuli programmed as S-. In Experiment 2, the equivalence class under reject control was expanded to four members (A1B2C1D2; A2B1C2D1). Participants had high scores only on symmetry and on transitivity and equivalence tests involving two nodes. Transfer of function was extended to the programmed S- added to each class. Results from both experiments suggest that select and reject controls might differently affect the formation of equivalence classes and the transfer of stimulus functions. © Society for the Experimental Analysis of Behavior.

  10. Correlation of heat transfer coefficient in quenching process using ABAQUS

    NASA Astrophysics Data System (ADS)

    Davare, Sandeep Kedarnath; Balachandran, G.; Singh, R. K. P.

    2018-04-01

    During the heat treatment by quenching in a liquid medium the convective heat transfer coefficient plays a crucial role in the extraction of heat. The heat extraction ultimately influences the cooling rate and hence the hardness and mechanical properties. A Finite Element analysis of quenching a simple flat copper sample with different orientation of sample and with different quenchant temperatures were carried out to check and verify the results obtained from the experiments. The heat transfer coefficient (HTC) was calculated from temperature history in a simple flat copper disc sample experimentally. This HTC data was further used as input to simulation software and the cooling curves were back calculated. The results obtained from software and using experimentation shows nearly consistent values.

  11. Fluid sampling system

    DOEpatents

    Houck, Edward D.

    1994-01-01

    An fluid sampling system allows sampling of radioactive liquid without spillage. A feed tank is connected to a liquid transfer jet powered by a pumping chamber pressurized by compressed air. The liquid is pumped upwardly into a sampling jet of a venturi design having a lumen with an inlet, an outlet, a constricted middle portion, and a port located above the constricted middle portion. The liquid is passed under pressure through the constricted portion causing its velocity to increase and its pressure to decreased, thereby preventing liquid from escaping. A septum sealing the port can be pierced by a two pointed hollow needle leading into a sample bottle also sealed by a pierceable septum affixed to one end. The bottle is evacuated by flow through the sample jet, cyclic variation in the sampler jet pressure periodically leaves the evacuated bottle with lower pressure than that of the port, thus causing solution to pass into the bottle. The remaining solution in the system is returned to the feed tank via a holding tank.

  12. Fluid sampling system

    DOEpatents

    Houck, E.D.

    1994-10-11

    An fluid sampling system allows sampling of radioactive liquid without spillage. A feed tank is connected to a liquid transfer jet powered by a pumping chamber pressurized by compressed air. The liquid is pumped upwardly into a sampling jet of a venturi design having a lumen with an inlet, an outlet, a constricted middle portion, and a port located above the constricted middle portion. The liquid is passed under pressure through the constricted portion causing its velocity to increase and its pressure to be decreased, thereby preventing liquid from escaping. A septum sealing the port can be pierced by a two pointed hollow needle leading into a sample bottle also sealed by a pierceable septum affixed to one end. The bottle is evacuated by flow through the sample jet, cyclic variation in the sampler jet pressure periodically leaves the evacuated bottle with lower pressure than that of the port, thus causing solution to pass into the bottle. The remaining solution in the system is returned to the feed tank via a holding tank. 4 figs.

  13. Use of a sparse sampling study design to assess transfer of tramadol and its O-desmethyl metabolite into transitional breast milk.

    PubMed

    Ilett, Kenneth F; Paech, Michael J; Page-Sharp, Madhu; Sy, Sherwin K; Kristensen, Judith H; Goy, Raymond; Chua, Sebastian; Christmas, Tracey; Scott, Karen L

    2008-05-01

    There are presently no published data on tramadol transfer into breast milk or on its effects in the breastfed infant. We have provided quantitative data on the absolute and relative infant doses of rac-tramadol and it rac-O-desmethyl metabolite for the breastfed infant. We have also demonstrated a novel sparse sampling data collection method for investigating infant exposure via milk. To investigate the transfer of rac-tramadol and its rac-O-desmethyl metabolite into transitional milk, and assess unwanted effects in the breastfed infant. Tramadol HCl (100 mg six hourly) was administered to 75 breastfeeding mothers for postoperative analgesia on days 2-4 after Caesarian section. Milk and plasma samples were collected after administration of four or more doses. Rac-tramadol and rac-O-desmethyltramadol were measured by high performance liquid chromatography. Milk : plasma ratio (M : P) and infant doses were calculated by standard methods. The behavioural characteristics of the exposed breastfed infants and a matched control group of infants not exposed to tramadol were also studied. RESULTS At steady-state, mean (95% CI) M : P was 2.2 (2.0, 2.4) for rac-tramadol and 2.8 (2.5, 3.1) for rac-O-desmethyltramadol. The estimated absolute and relative infant doses were 112 (102, 122) microg kg(-1) day(-1) and 30 (28, 32) microg kg(-1) day(-1), and 2.24% (2.04, 2.44)% and 0.64% (0.59, 0.69)% for rac-tramadol and rac-O-desmethyltramadol, respectively. The exposed infants and control breastfed infants had similar characteristics, including Apgar scores at birth and Neurologic and Adaptive Capacity Scores. The combined relative infant dose of 2.88% at steady-state was low. The similarity of NACS in exposed infants and controls suggests that there were no significant behavioural adverse effects. We conclude that short-term maternal use of tramadol during establishment of lactation is compatible with breastfeeding.

  14. Donor-Acceptor Distance Sampling Enhances the Performance of "Better than Nature" Nicotinamide Coenzyme Biomimetics.

    PubMed

    Geddes, Alexander; Paul, Caroline E; Hay, Sam; Hollmann, Frank; Scrutton, Nigel S

    2016-09-07

    Understanding the mechanisms of enzymatic hydride transfer with nicotinamide coenzyme biomimetics (NCBs) is critical to enhancing the performance of nicotinamide coenzyme-dependent biocatalysts. Here the temperature dependence of kinetic isotope effects (KIEs) for hydride transfer between "better than nature" NCBs and several ene reductase biocatalysts is used to indicate transfer by quantum mechanical tunneling. A strong correlation between rate constants and temperature dependence of the KIE (ΔΔH(⧧)) for H/D transfer implies that faster reactions with NCBs are associated with enhanced donor-acceptor distance sampling. Our analysis provides the first mechanistic insight into how NCBs can outperform their natural counterparts and emphasizes the need to optimize donor-acceptor distance sampling to obtain high catalytic performance from H-transfer enzymes.

  15. Method of remotely characterizing thermal properties of a sample

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S. (Inventor); Heath, D. Michele (Inventor); Welch, Christopher (Inventor); Winfree, William P. (Inventor); Miller, William E. (Inventor)

    1992-01-01

    A sample in a wind tunnel is radiated from a thermal energy source outside of the wind tunnel. A thermal imager system, also located outside of the wind tunnel, reads surface radiations from the sample as a function of time. The produced thermal images are characteristic of the heat transferred from the sample to the flow across the sample. In turn, the measured rates of heat loss of the sample are characteristic of the flow and the sample.

  16. Adhesion in a Vacuum Environment and its Implications for Dust Mitigation Techniques on Airless Bodies

    NASA Technical Reports Server (NTRS)

    Berkebile, Stephen; Gaier, James R.

    2012-01-01

    During the Apollo missions, the adhesion of dust to critical spacecraft systems was a greater problem than anticipated and resulted in functional degradation of thermal control surfaces, spacesuit seals, and other spacecraft components. Notably, Earth-based simulation efforts did not predict the magnitude and effects of dust adhesion in the lunar environment. Forty years later, we understand that the ultrahigh vacuum (UHV) environment, coupled with micrometeorite impacts and constant ion and photon bombardment from the sun result in atomically clean and high surface energy dust particles and spacecraft surfaces. However, both the dominant mechanism of adhesion in airless environments and the conditions for high fidelity simulation tests have still to be determined. The experiments presented in here aim to aid in the development of dust mitigation techniques for airless bodies (e.g., lunar surface, asteroids, moons of outer planets). The approach taken consists of (a) quantifying the adhesion between common polymer and metallic spacecraft materials and a synthetic noritic volcanic glass, as a function of surface cleanliness and of triboelectric charge transfer in a UHV environment, and (b) determining parameters for high fidelity tests through investigation of adhesion dependence on vacuum environment and sample treatment. Adhesion force has been measured between pins of spacecraft materials and a plate of synthetic volcanic glass by determining the pull-off force with a torsion balance. Although no significant adhesion is generally observed directly as a result of high surface energies, the adhesion due to induced electrostatic charge is observed to increase with spacecraft material cleanliness, in some cases by over a factor of 10. Furthermore, electrostatically-induced adhesion is found to decrease rapidly above pressures of 10-6 torr. It is concluded that high-fidelity tests should be conducted in high to ultrahigh vacuum and include an ionized surface cleaning

  17. Mass transfer characteristics of bisporus mushroom ( Agaricus bisporus) slices during convective hot air drying

    NASA Astrophysics Data System (ADS)

    Ghanbarian, Davoud; Baraani Dastjerdi, Mojtaba; Torki-Harchegani, Mehdi

    2016-05-01

    An accurate understanding of moisture transfer parameters, including moisture diffusivity and moisture transfer coefficient, is essential for efficient mass transfer analysis and to design new dryers or improve existing drying equipments. The main objective of the present study was to carry out an experimental and theoretical investigation of mushroom slices drying and determine the mass transfer characteristics of the samples dried under different conditions. The mushroom slices with two thicknesses of 3 and 5 mm were dried at air temperatures of 40, 50 and 60 °C and air flow rates of 1 and 1.5 m s-1. The Dincer and Dost model was used to determine the moisture transfer parameters and predict the drying curves. It was observed that the entire drying process took place in the falling drying rate period. The obtained lag factor and Biot number indicated that the moisture transfer in the samples was controlled by both internal and external resistance. The effective moisture diffusivity and the moisture transfer coefficient increased with increasing air temperature, air flow rate and samples thickness and varied in the ranges of 6.5175 × 10-10 to 1.6726 × 10-9 m2 s-1 and 2.7715 × 10-7 to 3.5512 × 10-7 m s-1, respectively. The validation of the Dincer and Dost model indicated a good capability of the model to describe the drying curves of the mushroom slices.

  18. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources.

    PubMed

    Pincelli, T; Petrov, V N; Brajnik, G; Ciprian, R; Lollobrigida, V; Torelli, P; Krizmancic, D; Salvador, F; De Luisa, A; Sergo, R; Gubertini, A; Cautero, G; Carrato, S; Rossi, G; Panaccione, G

    2016-03-01

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

  19. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

    NASA Astrophysics Data System (ADS)

    Pincelli, T.; Petrov, V. N.; Brajnik, G.; Ciprian, R.; Lollobrigida, V.; Torelli, P.; Krizmancic, D.; Salvador, F.; De Luisa, A.; Sergo, R.; Gubertini, A.; Cautero, G.; Carrato, S.; Rossi, G.; Panaccione, G.

    2016-03-01

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

  20. Design and performance of an ultra-high vacuum spin-polarized scanning tunneling microscope operating at 30 mK and in a vector magnetic field

    NASA Astrophysics Data System (ADS)

    von Allwörden, Henning; Eich, Andreas; Knol, Elze J.; Hermenau, Jan; Sonntag, Andreas; Gerritsen, Jan W.; Wegner, Daniel; Khajetoorians, Alexander A.

    2018-03-01

    We describe the design and performance of a scanning tunneling microscope (STM) that operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution refrigerator that contains a vector magnet allowing for fields up to 9 T perpendicular and 4 T parallel to the sample. The STM is placed in a multi-chamber UHV system, which allows in situ preparation and exchange of samples and tips. The entire system rests on a 150-ton concrete block suspended by pneumatic isolators, which is housed in an acoustically isolated and electromagnetically shielded laboratory optimized for extremely low noise scanning probe measurements. We demonstrate the overall performance by illustrating atomic resolution and quasiparticle interference imaging and detail the vibrational noise of both the laboratory and microscope. We also determine the electron temperature via measurement of the superconducting gap of Re(0001) and illustrate magnetic field-dependent measurements of the spin excitations of individual Fe atoms on Pt(111). Finally, we demonstrate spin resolution by imaging the magnetic structure of the Fe double layer on W(110).

  1. Design and performance of an ultra-high vacuum spin-polarized scanning tunneling microscope operating at 30 mK and in a vector magnetic field.

    PubMed

    von Allwörden, Henning; Eich, Andreas; Knol, Elze J; Hermenau, Jan; Sonntag, Andreas; Gerritsen, Jan W; Wegner, Daniel; Khajetoorians, Alexander A

    2018-03-01

    We describe the design and performance of a scanning tunneling microscope (STM) that operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution refrigerator that contains a vector magnet allowing for fields up to 9 T perpendicular and 4 T parallel to the sample. The STM is placed in a multi-chamber UHV system, which allows in situ preparation and exchange of samples and tips. The entire system rests on a 150-ton concrete block suspended by pneumatic isolators, which is housed in an acoustically isolated and electromagnetically shielded laboratory optimized for extremely low noise scanning probe measurements. We demonstrate the overall performance by illustrating atomic resolution and quasiparticle interference imaging and detail the vibrational noise of both the laboratory and microscope. We also determine the electron temperature via measurement of the superconducting gap of Re(0001) and illustrate magnetic field-dependent measurements of the spin excitations of individual Fe atoms on Pt(111). Finally, we demonstrate spin resolution by imaging the magnetic structure of the Fe double layer on W(110).

  2. Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: A modular vacuum ultraviolet source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sloan Roberts, F.; Anderson, Scott L.

    2013-12-15

    The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a “soft” photoionization source for gas-phase massmore » spectrometry.« less

  3. Dynamics driving function: new insights from electron transferring flavoproteins and partner complexes.

    PubMed

    Toogood, Helen S; Leys, David; Scrutton, Nigel S

    2007-11-01

    Electron transferring flavoproteins (ETFs) are soluble heterodimeric FAD-containing proteins that function primarily as soluble electron carriers between various flavoprotein dehydrogenases. ETF is positioned at a key metabolic branch point, responsible for transferring electrons from up to 10 primary dehydrogenases to the membrane-bound respiratory chain. Clinical mutations of ETF result in the often fatal disease glutaric aciduria type II. Structural and biophysical studies of ETF in complex with partner proteins have shown that ETF partitions the functions of partner binding and electron transfer between (a) a 'recognition loop', which acts as a static anchor at the ETF-partner interface, and (b) a highly mobile redox-active FAD domain. Together, this enables the FAD domain of ETF to sample a range of conformations, some compatible with fast interprotein electron transfer. This 'conformational sampling' enables ETF to recognize structurally distinct partners, whilst also maintaining a degree of specificity. Complex formation triggers mobility of the FAD domain, an 'induced disorder' mechanism contrasting with the more generally accepted models of protein-protein interaction by induced fit mechanisms. We discuss the implications of the highly dynamic nature of ETFs in biological interprotein electron transfer. ETF complexes point to mechanisms of electron transfer in which 'dynamics drive function', a feature that is probably widespread in biology given the modular assembly and flexible nature of biological electron transfer systems.

  4. X-Ray Scattering Studies of the Liquid-Vapor Interface of Gallium.

    NASA Astrophysics Data System (ADS)

    Kawamoto, Eric Hitoshi

    A UHV system was developed for performing X-ray scattering studies and in situ analyses of liquid metal surfaces. A nearly ideal choice for this study, gallium has a melting point just above room temperature; is amenable to handling in both air and vacuum; its surface oxides can be removed while its cleanliness is maintained and monitored. Using argon glow-discharge sputtering techniques to remove intervening surface oxides, thin wetting layers of gallium were prepared atop nonreactive substrates, to be used as samples suited for liquid surface scattering experiments. Preliminary measurements of X-ray reflectivity from the liquid-vapor interface of gallium were performed with the X-ray UHV chamber configured for use in conjunction with liquid surface spectrometers at two synchrotron beamlines. A novel technique for carrying out and interpreting scattering measurements from curved liquid surfaces was demonstrated. The energy tunability and intense focused white beam flux from a wiggler source was shown to place within reach the large values of wavevector transfer at which specular reflectivity data yield small length scale information about surface structure. Various theoretical treatments and simulations predict quasi-lamellar ordering of atoms near the free surface of metallic liquids due to energetics particular to metals (electron delocalization, the dependence of system energy on ion and electron densities, surface tension and electrostatic energy). However, the experimental data reported to date is insufficient to distinguish between a monotonic, sigmoidal electron density profile found at the free surfaces of dielectric liquids, and the damped oscillatory layer-like profiles anticipated for metallic liquids. Out to a wavevector transfer of Q = 0.55 A ^{-1}, the reflectivity data measured from a curved Ga surface is not inconsistent with what is expected for a liquid-vapor electron density profile of Gaussian width sigma = 1.3 +/- 0.2 A. Subsequent

  5. A Longitudinal Quasi-Experiment on the Effects of Posttraining Transfer Interventions

    ERIC Educational Resources Information Center

    Gaudine, Alice P.; Saks, Alan M.

    2004-01-01

    A longitudinal quasi experiment tested the effects of a relapse prevention and transfer enhancement posttraining intervention on the self-efficacy, transfer behavior, and performance of a sample of nurses who attended a two-day training program on the McGill Model of Nursing. ANCOVA results failed to support the effectiveness of the intervention;…

  6. Heat Transfer Measurements on Surfaces with Natural Ice Castings and Modeled Roughness

    NASA Technical Reports Server (NTRS)

    Breuer, Kenneth S.; Torres, Benjamin E.; Orr, D. J.; Hansman, R. John

    1997-01-01

    An experimental method is described to measure and compare the convective heat transfer coefficient of natural and simulated ice accretion roughness and to provide a rational means for determining accretion-related enhanced heat transfer coefficients. The natural ice accretion roughness was a sample casting made from accretions at the NASA Lewis Icing Research Tunnel (IRT). One of these castings was modeled using a Spectral Estimation Technique (SET) to produce three roughness elements patterns that simulate the actual accretion. All four samples were tested in a flat-plate boundary layer at angle of attack in a "dry" wind tunnel test. The convective heat transfer coefficient was measured using infrared thermography. It is shown that, dispite some problems in the current data set, the method does show considerable promise in determining roughness-induced heat transfer coefficients, and that, in addition to the roughness height and spacing in the flow direction, the concentration and spacing of elements in the spanwise direction are important parameters.

  7. Efficient radiative transfer methods for continuum and line transfer in large three-dimensional models

    NASA Astrophysics Data System (ADS)

    Juvela, Mika J.

    to this problem (Juvela & Padoan, 2000; Hogerheijde & van der Tak, 2000). AMC methods can be used similarly in continuum calculations to speed up the computation of dust temperatures (Juvela, 2005). The sampling problems associated with high optical depths can be solved with weighted sampling and the handling of models with τV ~ 1000 is perfectly feasible. Transiently heated small dust grains pose another problem because the calculation of their temperature distribution is very time consuming. However, a 3D model will contain thousands of cells at very similar conditions. If dust temperature distributions are calculated only once for such a set an approximate solution can be found in a much shorter time time. (Juvela & Padoan, 2003; see Figure 2a). MHD simulations with Automatic Mesh Refinement (AMR) techniques present an exciting development for the modelling of interstellar clouds. Cloud models consist of a hierarchy of grids with different grid steps and the ratio between the cloud size and the smallest resolution elements can be 106 or even larger. We are currently working on radiative transfer codes (line and continuum) that could be used efficiently on such grids (see Figure 2b). The radiative transfer problem can be solved relatively independently on each of the sub-grids. This means that the use of convergence acceleration methods can be limited to those sub-grids where they are needed and, on the other hand, parallelization of the code is straightforward.

  8. Advanced Curation Protocols for Mars Returned Sample Handling

    NASA Astrophysics Data System (ADS)

    Bell, M.; Mickelson, E.; Lindstrom, D.; Allton, J.

    Introduction: Johnson Space Center has over 30 years experience handling precious samples which include Lunar rocks and Antarctic meteorites. However, we recognize that future curation of samples from such missions as Genesis, Stardust, and Mars S mple Return, will require a high degree of biosafety combined witha extremely low levels of inorganic, organic, and biological contamination. To satisfy these requirements, research in the JSC Advanced Curation Lab is currently focused toward two major areas: preliminary examination techniques and cleaning and verification techniques . Preliminary Examination Techniques : In order to minimize the number of paths for contamination we are exploring the synergy between human &robotic sample handling in a controlled environment to help determine the limits of clean curation. Within the Advanced Curation Laboratory is a prototype, next-generation glovebox, which contains a robotic micromanipulator. The remotely operated manipulator has six degrees-of- freedom and can be programmed to perform repetitive sample handling tasks. Protocols are being tested and developed to perform curation tasks such as rock splitting, weighing, imaging, and storing. Techniques for sample transfer enabling more detailed remote examination without compromising the integrity of sample science are also being developed . The glovebox is equipped with a rapid transfer port through which samples can be passed without exposure. The transfer is accomplished by using a unique seal and engagement system which allows passage between containers while maintaining a first seal to the outside environment and a second seal to prevent the outside of the container cover and port door from becoming contaminated by the material being transferred. Cleaning and Verification Techniques: As part of the contamination control effort, innovative cleaning techniques are being identified and evaluated in conjunction with sensitive cleanliness verification methods. Towards this

  9. Transfer Factors for Contaminant Uptake by Fruit and Nut Trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napier, Bruce A.; Fellows, Robert J.; Minc, Leah D.

    Transfer of radionuclides from soils into plants is one of the key mechanisms for long-term contamination of the human food chain. Nearly all computer models that address soil-to-plant uptake of radionuclides use empirically-derived transfer factors to address this process. Essentially all available soil-to-plant transfer factors are based on measurements in annual crops. Because very few measurements are available for tree fruits, samples were taken of alfalfa and oats and the stems, leaves, and fruits and nuts of almond, apple, apricot, carob, fig, grape, nectarine, pecan, pistachio (natural and grafted), and pomegranate, along with local surface soil. The samples were dried,more » ground, weighed, and analyzed for trace constituents through a combination of induction-coupled plasma mass spectrometry and instrumental neutron activation analysis for a wide range of naturally-occurring elements. Analysis results are presented and converted to soil-to-plant transfer factors. These are compared to commonly used and internationally recommended values. Those determined for annual crops are very similar to commonly-used values; those determined for tree fruits show interesting differences. Most macro- and micronutrients are slightly reduced in fruits; non-essential elements are reduced further. These findings may be used in existing computer models and may allow development of tree-fruit-specific transfer models.« less

  10. Characterization and Evaluation of Ti-Zr-V Non-evaporable Getter Films Used in Vacuum Systems

    NASA Astrophysics Data System (ADS)

    Ferreira, M. J.; Seraphim, R. M.; Ramirez, A. J.; Tabacniks, M. H.; Nascente, P. A. P.

    Among several methods used to obtain ultra-high vacuum (UHV) for particles accelerators chambers, it stands out the internal coating with metallic films capable of absorbing gases, called NEG (non-evaporable getter). Usually these materials are constituted by elements of great chemical reactivity and solubility (such as Ti, Zr, and V), at room temperature for oxygen and other gases typically found in UHV, such as H2, CO, and CO2. Gold and ternary Ti-Zr-V films were produced by magnetron sputtering, and their composition, structure, morphology, and aging characteristics were characterized by energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), field emission gun sc anning electronmicroscopy (FEG-SEM), atomic force microscopy (AFM), high resolution transmission electron microscopy (HRTEM). The comparison between the produced films and commercial samples indicated that the desirable characteristics depend on the nanometric structure of the films and that this structure is sensitive to the heat treatments.

  11. Heat transfer mechanisms in poplar wood undergoing torrefaction

    NASA Astrophysics Data System (ADS)

    Sule, Idris O.; Mahmud, Shohel; Dutta, Animesh; Tasnim, Syeda Humaira

    2016-03-01

    Torrefaction, a thermal treatment process of biomass, has been proved to improve biomass combustible properties. Torrefaction is defined as a thermochemical process in reduced oxygen condition and at temperature range from 200 to 300 °C for shorter residence time whereby energy yield is maximized, can be a bridging technology that can lead the conventional system (e.g. coal-fired plants) towards a sustainable energy system. In efforts to develop a commercial operable torrefaction reactor, the present study examines the minimum input condition at which biomass is torrefied and explores the heat transfer mechanisms during torrefaction in poplar wood samples. The heat transfer through the wood sample is numerically modeled and analyzed. Each poplar wood is torrefied at temperature of 250, 270, and 300 °C. The experimental study shows that the 270 °C-treatment can be deduced as the optimal input condition for torrefaction of poplar wood. A good understanding of heat transfer mechanisms can facilitate the upscaling and downscaling of torrefaction process equipment to fit the feedstock input criteria and can help to develop treatment input specifications that can maximize process efficiency.

  12. Lattice Boltzmann heat transfer model for permeable voxels

    NASA Astrophysics Data System (ADS)

    Pereira, Gerald G.; Wu, Bisheng; Ahmed, Shakil

    2017-12-01

    We develop a gray-scale lattice Boltzmann (LB) model to study fluid flow combined with heat transfer for flow through porous media where voxels may be partially solid (or void). Heat transfer in rocks may lead to deformation, which in turn can modulate the fluid flow and so has significant contribution to rock permeability. The LB temperature field is compared to a finite difference solution of the continuum partial differential equations for fluid flow in a channel. Excellent quantitative agreement is found for both Poiseuille channel flow and Brinkman flow. The LB model is then applied to sample porous media such as packed beds and also more realistic sandstone rock sample, and both the convective and diffusive regimes are recovered when varying the thermal diffusivity. It is found that while the rock permeability can be comparatively small (order milli-Darcy), the temperature field can show significant variation depending on the thermal convection of the fluid. This LB method has significant advantages over other numerical methods such as finite and boundary element methods in dealing with coupled fluid flow and heat transfer in rocks which have irregular and nonsmooth pore spaces.

  13. Heat Transfer Modeling and Validation for Optically Thick Alumina Fibrous Insulation

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran

    2009-01-01

    Combined radiation/conduction heat transfer through unbonded alumina fibrous insulation was modeled using the diffusion approximation for modeling the radiation component of heat transfer in the optically thick insulation. The validity of the heat transfer model was investigated by comparison to previously reported experimental effective thermal conductivity data over the insulation density range of 24 to 96 kg/cu m, with a pressure range of 0.001 to 750 torr (0.1 to 101.3 x 10(exp 3) Pa), and test sample hot side temperature range of 530 to 1360 K. The model was further validated by comparison to thermal conductivity measurements using the transient step heating technique on an insulation sample at a density of 144 kg/cu m over a pressure range of 0.001 to 760 torr, and temperature range of 290 to 1090 K.

  14. Factors Affecting the Transfer of Basic Combat Skills Training in the Air Force

    DTIC Science & Technology

    2006-03-01

    Kaiser - Meyer - Olkin Measure of Sampling Adequacy (KMO) and Bartlett’s test of Sphericity. The items reported a KMO=.87 and χ2 = 5,158.57, p < .01...Results Factor Analysis Table E1 Kaiser - Meyer - Olkin (KMO) and Bartlett’s Test of Sphericity for Perceived Training Transfer and Transfer Enhancing...Activities KMO Χ2 df Sig. Kaiser - Meyer - Olkin Measure of Sampling Adequacy .87 Bartletts Test of Sphericity 5,158.57 66 .000 100

  15. Orbital Transfer Techniques for Round-Trip Mars Missions

    NASA Astrophysics Data System (ADS)

    Landau, D. F.; Barbee, B. W.; Woolley, R. C.; Gershman, R.

    2012-06-01

    Efficient methods to transfer among a variety of Mars orbits is presented. Emphasis is placed on connecting arrival and departure interplanetary trajectories to an arbitrary circular target orbit for a hybrid human/robotic Mars sample return mission.

  16. Oxidation of palladium on Au(111) and ZnO(0001) supports

    DOE PAGES

    Lallo, J.; Tenney, S. A.; Kramer, A.; ...

    2014-10-21

    The oxidation of supported Pd-deposits on Au(111) and ZnO(0001) single crystals has been studied by x- ray photoemission spectroscopy (XPS). Oxidation has been carried out ex-situ in a high-pressure cell with subsequent vacuum-transfer and characterization by XPS in ultrahigh vacuum (UHV), as well as using in-situ characterization by synchrotron based near-ambient pressure XPS. On Au(111) alloying of Pd with the substrate competes with oxidation and only sufficiently thick Pd films have been found to oxidize. For Pd on ZnO the oxidation conditions depend on the amount of deposited Pd. Thicker Pd deposits behave similar to bulk Pd, while thinner filmsmore » oxidize already at lower temperatures. Interestingly, for very small amounts of Pd, in-situ XPS shows full oxidation at room temperature and at less than 0.6 mbar O₂ pressure. This indicates a lowering of the kinetic barriers for oxidation of very small supported Pd-clusters. The formed oxide is, however, not stable in UHV and a slow reduction is observed. The instability of this oxide indicates that the Pd-oxide formed at the interface to ZnO may have different chemical properties compared to bulk PdO or surface oxides on Pd.« less

  17. Technology Transfer Issues and a New Technology Transfer Model

    ERIC Educational Resources Information Center

    Choi, Hee Jun

    2009-01-01

    The following are major issues that should be considered for efficient and effective technology transfer: conceptions of technology, technological activity and transfer, communication channels, factors affecting transfer, and models of transfer. In particular, a well-developed model of technology transfer could be used as a framework for…

  18. Intergenerational private transfers: Portugal in the European context.

    PubMed

    Albuquerque, Paula C

    2014-12-01

    Intergenerational private transfers should be made important as a common occurrence in familialistic societies when establishing the identity of Southern European welfare state regimes. They function as a safety net and as a way of reinforcing the bonds amongst elements in a family. Although Portugal is undoubtedly a Southern European country, it is frequently ignored in comparative studies, and is assumed to share the characteristics of Spain and Italy. But do these countries really belong to a common, distinctive model? Portugal was included in the fourth wave of the survey of health, ageing and retirement in Europe, which provides a large sample for the study of intergenerational private transfers in this country. It also enables comparison with what happens elsewhere in Europe. We examine the upward and downward flows between generations and identify several important determinants of each type of transfers. Additionally, we show that the different types and directions of transfers are positively correlated, pointing to a self-reinforcement of transfer behaviour in families. We find that Portugal has an especially low probability of private transfers of time and money. After taking into consideration the household-level characteristics, none of the countries included in this study has a significantly lower probability of occurrence of any type of transfer than that of Portugal. A Southern European specific pattern of family transfers is only partially confirmed, yet Portugal and Spain do share the same model.

  19. Effect of the different chain transfer agents on molecular weight and optical properties of poly(methyl methacrylate)

    NASA Astrophysics Data System (ADS)

    Çetinkaya, Onur; Demirci, Gökhan; Mergo, Paweł

    2017-08-01

    Investigation of molecular weight and optical properties of poly(methyl metacrylate) (PMMA) polymerized in house with different chain transfer agents was studied. Isopropyl alcohol (IPA), n-butyl mercaptan (nBMC) and pentamethyl disilane (PMDS) were used as chain transfer agents. The molecular weight (Mw) of PMMA samples were measured by Ostwald viscometer. Mw of bulk polymer samples were decreased with increase the concentration of chain transfer agents (CTA). Since reactivity of used CTAs is not same, molecular weights of samples which were produced with different type of CTA but same concentration of CTA was varied. Higher concentration of n-BMC showed higher scattering. Transmission of samples could not be correlated with different concentration of CTA. Refractive index of samples was not affected by concentration of CTA nevertheless higher molecular weight of CTA showed higher refractive index.

  20. The Relation of Self Variables to Transfer Student Success as Measured by Academic, Psychological, and Career Functioning

    ERIC Educational Resources Information Center

    Ling, Thomson Joseph

    2006-01-01

    Research has suggested that transfer students experience difficulty in many domains however limited research has examined the variables associated with transfer student success. The present study examined transfer student success using a sample of 163 first-year transfer students at a large mid-Atlantic university. The mean age of the participants…

  1. Energy transfer of nucleic acid products

    NASA Astrophysics Data System (ADS)

    Jung, Paul M.; Hu, Hsiang-Yun; Khalil, Omar S.

    1995-04-01

    Fluorescence energy transfer was investigated as a homogeneous detection method for the gapped ligase chain reaction (G-LCR). Oligonucleotides of a Chlamydia trachomatic G-LCR probe set were labeled with fluorescein as the donor and Texas Red as the acceptor fluorophore. Amplification and detection of 10 molecules of synthetic target was demonstrated in spiked urine samples.

  2. Using transfer learning to detect galaxy mergers

    NASA Astrophysics Data System (ADS)

    Ackermann, Sandro; Schawinksi, Kevin; Zhang, Ce; Weigel, Anna K.; Turp, M. Dennis

    2018-05-01

    We investigate the use of deep convolutional neural networks (deep CNNs) for automatic visual detection of galaxy mergers. Moreover, we investigate the use of transfer learning in conjunction with CNNs, by retraining networks first trained on pictures of everyday objects. We test the hypothesis that transfer learning is useful for improving classification performance for small training sets. This would make transfer learning useful for finding rare objects in astronomical imaging datasets. We find that these deep learning methods perform significantly better than current state-of-the-art merger detection methods based on nonparametric systems like CAS and GM20. Our method is end-to-end and robust to image noise and distortions; it can be applied directly without image preprocessing. We also find that transfer learning can act as a regulariser in some cases, leading to better overall classification accuracy (p = 0.02). Transfer learning on our full training set leads to a lowered error rate from 0.0381 down to 0.0321, a relative improvement of 15%. Finally, we perform a basic sanity-check by creating a merger sample with our method, and comparing with an already existing, manually created merger catalogue in terms of colour-mass distribution and stellar mass function.

  3. A Review of Calibration Transfer Practices and Instrument Differences in Spectroscopy.

    PubMed

    Workman, Jerome J

    2018-03-01

    Calibration transfer for use with spectroscopic instruments, particularly for near-infrared, infrared, and Raman analysis, has been the subject of multiple articles, research papers, book chapters, and technical reviews. There has been a myriad of approaches published and claims made for resolving the problems associated with transferring calibrations; however, the capability of attaining identical results over time from two or more instruments using an identical calibration still eludes technologists. Calibration transfer, in a precise definition, refers to a series of analytical approaches or chemometric techniques used to attempt to apply a single spectral database, and the calibration model developed using that database, for two or more instruments, with statistically retained accuracy and precision. Ideally, one would develop a single calibration for any particular application, and move it indiscriminately across instruments and achieve identical analysis or prediction results. There are many technical aspects involved in such precision calibration transfer, related to the measuring instrument reproducibility and repeatability, the reference chemical values used for the calibration, the multivariate mathematics used for calibration, and sample presentation repeatability and reproducibility. Ideally, a multivariate model developed on a single instrument would provide a statistically identical analysis when used on other instruments following transfer. This paper reviews common calibration transfer techniques, mostly related to instrument differences, and the mathematics of the uncertainty between instruments when making spectroscopic measurements of identical samples. It does not specifically address calibration maintenance or reference laboratory differences.

  4. The resolution capability of an irregularly sampled dataset: With application to Geosat altimeter data

    NASA Technical Reports Server (NTRS)

    Chelton, Dudley B.; Schlax, Michael G.

    1994-01-01

    A formalism is presented for determining the wavenumber-frequency transfer function associated with an irregularly sampled multidimensional dataset. This transfer function reveals the filtering characteristics and aliasing patterns inherent in the sample design. In combination with information about the spectral characteristics of the signal, the transfer function can be used to quantify the spatial and temporal resolution capability of the dataset. Application of the method to idealized Geosat altimeter data (i.e., neglecting measurement errors and data dropouts) concludes that the Geosat orbit configuration is capable of resolving scales of about 3 deg in latitude and longitude by about 30 days.

  5. Transferability and Fine-Mapping of Genome-Wide Associated Loci for Adult Height across Human Populations

    PubMed Central

    Shriner, Daniel; Adeyemo, Adebowale; Gerry, Norman P.; Herbert, Alan; Chen, Guanjie; Doumatey, Ayo; Huang, Hanxia; Zhou, Jie; Christman, Michael F.; Rotimi, Charles N.

    2009-01-01

    Human height is the prototypical polygenic quantitative trait. Recently, several genetic variants influencing adult height were identified, primarily in individuals of East Asian (Chinese Han or Korean) or European ancestry. Here, we examined 152 genetic variants representing 107 independent loci previously associated with adult height for transferability in a well-powered sample of 1,016 unrelated African Americans. When we tested just the reported variants originally identified as associated with adult height in individuals of East Asian or European ancestry, only 8.3% of these loci transferred (p-values≤0.05 under an additive genetic model with directionally consistent effects) to our African American sample. However, when we comprehensively evaluated all HapMap variants in linkage disequilibrium (r 2≥0.3) with the reported variants, the transferability rate increased to 54.1%. The transferability rate was 70.8% for associations originally reported as genome-wide significant and 38.0% for associations originally reported as suggestive. An additional 23 loci were significantly associated but failed to transfer because of directionally inconsistent effects. Six loci were associated with adult height in all three groups. Using differences in linkage disequilibrium patterns between HapMap CEU or CHB reference data and our African American sample, we fine-mapped these six loci, improving both the localization and the annotation of these transferable associations. PMID:20027299

  6. Heat transfer from an oxidized large copper surface to liquid helium: Dependence on surface orientation and treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iwamoto, A.; Mito, T.; Takahata, K.

    Heat transfer of large copper plates (18 x 76 mm) in liquid helium has been measured as a function of orientation and treatment of the heat transfer surface. The results relate to applications of large scale superconductors. In order to clarify the influence of the area where the surface treatment peels off, the authors studied five types of heat transfer surface areas including: (a) 100% polished copper sample, (b) and (c) two 50% oxidized copper samples having different patterns of oxidation, (d) 75% oxidized copper sample, (e) 90% oxidized copper sample, and (f) 100% oxidized copper sample. They observed thatmore » the critical heat flux depends on the heat transfer surface orientation. The critical heat flux is a maximum at angles of 0{degrees} - 30{degrees} and decreases monotonically with increasing angles above 30{degrees}, where the angle is taken in reference to the horizontal axis. On the other hand, the minimum heat flux is less dependent on the surface orientation. More than 75% oxidation on the surface makes the critical heat flux increase. The minimum heat fluxes of the 50 and 90% oxidized Cu samples approximately agree with that of the 100% oxidized Cu sample. Experiments and calculations show that the critical and the minimum heat fluxes are a bilinear function of the fraction of oxidized surface area.« less

  7. Role of soil-to-leaf tritium transfer in controlling leaf tritium dynamics: Comparison of experimental garden and tritium-transfer model results.

    PubMed

    Ota, Masakazu; Kwamena, Nana-Owusua A; Mihok, Steve; Korolevych, Volodymyr

    2017-11-01

    Environmental transfer models assume that organically-bound tritium (OBT) is formed directly from tissue-free water tritium (TFWT) in environmental compartments. Nevertheless, studies in the literature have shown that measured OBT/HTO ratios in environmental samples are variable and generally higher than expected. The importance of soil-to-leaf HTO transfer pathway in controlling the leaf tritium dynamics is not well understood. A model inter-comparison of two tritium transfer models (CTEM-CLASS-TT and SOLVEG-II) was carried out with measured environmental samples from an experimental garden plot set up next to a tritium-processing facility. The garden plot received one of three different irrigation treatments - no external irrigation, irrigation with low tritium water and irrigation with high tritium water. The contrast between the results obtained with the different irrigation treatments provided insights into the impact of soil-to-leaf HTO transfer on the leaf tritium dynamics. Concentrations of TFWT and OBT in the garden plots that were not irrigated or irrigated with low tritium water were variable, responding to the arrival of the HTO-plume from the tritium-processing facility. In contrast, for the plants irrigated with high tritium water, the TFWT concentration remained elevated during the entire experimental period due to a continuous source of high HTO in the soil. Calculated concentrations of OBT in the leaves showed an initial increase followed by quasi-equilibration with the TFWT concentration. In this quasi-equilibrium state, concentrations of OBT remained elevated and unchanged despite the arrivals of the plume. These results from the model inter-comparison demonstrate that soil-to-leaf HTO transfer significantly affects tritium dynamics in leaves and thereby OBT/HTO ratio in the leaf regardless of the atmospheric HTO concentration, only if there is elevated HTO concentrations in the soil. The results of this work indicate that assessment models

  8. Domain adaptation via transfer component analysis.

    PubMed

    Pan, Sinno Jialin; Tsang, Ivor W; Kwok, James T; Yang, Qiang

    2011-02-01

    Domain adaptation allows knowledge from a source domain to be transferred to a different but related target domain. Intuitively, discovering a good feature representation across domains is crucial. In this paper, we first propose to find such a representation through a new learning method, transfer component analysis (TCA), for domain adaptation. TCA tries to learn some transfer components across domains in a reproducing kernel Hilbert space using maximum mean miscrepancy. In the subspace spanned by these transfer components, data properties are preserved and data distributions in different domains are close to each other. As a result, with the new representations in this subspace, we can apply standard machine learning methods to train classifiers or regression models in the source domain for use in the target domain. Furthermore, in order to uncover the knowledge hidden in the relations between the data labels from the source and target domains, we extend TCA in a semisupervised learning setting, which encodes label information into transfer components learning. We call this extension semisupervised TCA. The main contribution of our work is that we propose a novel dimensionality reduction framework for reducing the distance between domains in a latent space for domain adaptation. We propose both unsupervised and semisupervised feature extraction approaches, which can dramatically reduce the distance between domain distributions by projecting data onto the learned transfer components. Finally, our approach can handle large datasets and naturally lead to out-of-sample generalization. The effectiveness and efficiency of our approach are verified by experiments on five toy datasets and two real-world applications: cross-domain indoor WiFi localization and cross-domain text classification.

  9. Sampling and Analysis Plan for Verification Sampling of LANL-Derived Residual Radionuclides in Soils within Tract A-18-2 for Land Conveyance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruedig, Elizabeth

    Public Law 105-119 directs the U.S. Department of Energy (DOE) to convey or transfer parcels of land to the Incorporated County of Los Alamos or their designees and to the Department of Interior, Bureau of Indian Affairs, in trust for the Pueblo de San Ildefonso. Los Alamos National Security is tasked to support DOE in conveyance and/or transfer of identified land parcels no later than September 2022. Under DOE Order 458.1, Radiation Protection of the Public and the Environment (O458.1, 2013) and Los Alamos National Laboratory (LANL or the Laboratory) implementing Policy 412 (P412, 2014), real property with the potentialmore » to contain residual radioactive material must meet the criteria for clearance and release to the public. This Sampling and Analysis Plan (SAP) is a second investigation of Tract A-18-2 for the purpose of verifying the previous sampling results (LANL 2017). This sample plan requires 18 projectspecific soil samples for use in radiological clearance decisions consistent with LANL Procedure ENV-ES-TP-238 (2015a) and guidance in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM, 2000). The sampling work will be conducted by LANL, and samples will be evaluated by a LANL-contracted independent lab. However, there will be federal review (verification) of all steps of the sampling process.« less

  10. The effect of expatriate knowledge transfer on subsidiaries’ performance: a moderating role of absorptive capacity

    NASA Astrophysics Data System (ADS)

    Arsawan, I. W. E.; Sanjaya, I. B.; Putra, I. K. M.; Sukarta, I. W.

    2018-01-01

    This study aims to examine the relationship between motivation and knowledge transfer to the subsidiaries performance and test the role of absorptive capacity as a moderating variable. The research uses quantitative design through questionnaires distribution with 5 Likert scales. The population frame is five-star hotel in Bali province, Indonesia which amounted to 63 units, the sample of research using proportional random sampling is 54 units and determined the distribution of questionnaires to 162 subsidiaries as the unit of analysis. The research model was built using the structural equation model and analyzed with smart pls- 3 software. The findings of the study revealed that subsidiaries motivation a significant effect on knowledge transfer, knowledge transfer a significant effect on subsidiaries performance, motivation a significant effect on subsidiaries performance and absorptive capacity moderated the relationship between knowledge transfer and subsidiaries performance. These findings suggest that subsidiaries and process of knowledge transfer through absorptive capacity play an important role, and that they have some impact on the subsidiaries performance.

  11. The psycholegal factors for juvenile transfer and reverse transfer evaluations.

    PubMed

    King, Christopher M

    2018-01-01

    It remains unclear whether forensic mental health assessments for juvenile reverse transfer (to juvenile court) are distinct from those for juvenile transfer (to adult court). This survey consisted of an updated review of transfer and reverse transfer laws (in jurisdictions that have both mechanisms) in light of the generally accepted three-factor model of functional legal capacities involved in transfer evaluations (i.e., risk, sophistication-maturity, and treatment amenability). Results indicated that a majority of states' reverse transfer statutes refer explicitly or implicitly to the same three psycholegal constructs identified as central for transfer. Given the legal similarity between transfer and reverse transfer, potential practice implications and directions for future research are discussed. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Transfer of Low Dose Aspirin Into Human Milk.

    PubMed

    Datta, Palika; Rewers-Felkins, Kathleen; Kallem, Raja Reddy; Baker, Teresa; Hale, Thomas W

    2017-05-01

    Aspirin has antipyretic and anti-inflammatory properties and is frequently used by pregnant and lactating women. However, its transfer in human milk when administered at low dose has not been reported. Research aim: This study aimed to evaluate the transfer of acetylsalicylic acid and its metabolite, salicylic acid, into human milk following the use of low dose aspirin. In this study, milk samples were collected at 0, 1, 2, 4, 8, 12, and 24 hours from seven breastfeeding women after a steady-state daily dose of 81 mg of aspirin. Milk levels of acetylsalicylic acid and salicylic acid were determined by liquid chromatography-tandem mass spectrometry. Acetylsalicylic acid levels were below the limit of quantification (0.61 ng/ml) in all the milk samples, whereas salicylic acid was detected at very low concentrations. The average concentration of salicylic acid observed was 24 ng/ml and the estimated relative infant dose was 0.4%. Acetylsalicylic acid transfer into milk is so low that it is undetectable even by highly sophisticated methodology. Salicylic acid does appear in the human milk in comparatively low amounts, which are probably subclinical in infants. Thus, the daily use of an 81-mg dose of aspirin should be considered safe during lactation.

  13. Advanced Photonic Sensors Enabled by Semiconductor Bonding

    DTIC Science & Technology

    2010-05-31

    a dry scroll backing pump to maintain the high differential pressure between the UV gun and the sample/analysis chamber. We also replaced the...semiconductor materials in an ultra-high vacuum (UHV) environment where the properties of the interface can be controlled with atomic-level precision. Such...year research program, we designed and constructed a unique system capable of fusion bonding two wafers in an ultra-high vacuum environment. This system

  14. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling.

    PubMed

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C; Joyce, Kevin P; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing ([Formula: see text] for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining [Formula: see text] compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to [Formula: see text]. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple [Formula: see text] correction improved agreement with experiment from [Formula: see text] to [Formula: see text], despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  15. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling

    NASA Astrophysics Data System (ADS)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C.; Joyce, Kevin P.; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing (R=0.98 for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining R=0.73 compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to R=0.93. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple pK_{ {a}} correction improved agreement with experiment from R=0.54 to R=0.66, despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  16. Survival of Salmonella on refrigerated chicken carcasses and subsequent transfer to cutting board.

    PubMed

    Jiménez, S M; Tiburzi, M C; Salsi, M S; Moguilevsky, M A; Pirovani, M E

    2009-06-01

    To determine the effect of refrigeration time and temperature on Salmonella cell numbers on inoculated chicken carcasses and their transfer to a plastic cutting board. The survival of Salmonella on chicken skin and the transfer to a plastic cutting board when exposed to different refrigeration temperatures (2, 6 or 8 degrees C) for 9 days were the two main issues on which this work focused. Two scenarios were carried out to ascertain these effects: carcasses treated with a decontaminating acetic acid solution and untreated carcasses. All of the contaminated carcasses remained contaminated after 9 days of refrigeration. However, on untreated samples, while Salmonella numbers increased almost 1.5 log at 8 degrees C, the pathogen numbers decreased about 1 log at 2 and 6 degrees C. On acid-treated samples, cell numbers slightly decreased at all of the temperatures studied. Temperature did not affect salmonellae transfer to the cutting board, but time did. Acid decontamination increased cell numbers transferred to the cutting board compared with untreated samples. Proper refrigeration at low temperatures did not allow Salmonella numbers to rise, regardless of which carcasses had been, or had not been, acid treated. Despite the fact that the rate of transfer was not affected by temperature, the acid treatment detached Salmonella cells from the chicken skin and, therefore, the probability of greater cross-contamination should be studied further. The results of this study may provide better information about the refrigeration conditions for fresh chicken storage and also determine if these, along with acetic acid decontamination of broiler chicken, would affect the pathogen transfer to a cutting board.

  17. Miniaturization of a homogeneous fluorescence immunoassay based on energy transfer using nanotiter plates as high-density sample carriers.

    PubMed

    Schobel, U; Coille, I; Brecht, A; Steinwand, G M; Gauglitz, G

    2001-11-01

    The miniaturization of a homogeneous competitive immunoassay to a final assay volume of 70 nL is described. As the sample carrier, disposable plastic nanotiter plates (NTP) with dimensions of 2 x 2 cm2 containing 25 x 25 wells, corresponding to approximately 15,000 wells on a traditional 96-well microtiter plate footprint, were used. Sample handling was accomplished by a piezoelectrically actuated micropipet. To reduce evaporation while pipetting the assays, the NTP was handled in a closed humid chamber and cooled to the point of condensation. To avoid washing steps, a homogeneous assay was developed that was based on energy-transfer (ET). As a model system, an antibody-based assay for the detection of the environmentally relevant compound, simazine, in drinking water was chosen. Antibodies were labeled with the long-wavelength-excitable sulfoindocyanine dye Cy5 (donor), and a tracer was synthesized by labeling BSA with a triazine derivative and the acceptor dye Cy5.5. At low analyte concentrations, the tracer was preferably bound to the antibody binding sites. As a result of the close proximity of Cy5.5 and Cy5, an efficient quenching of the Cy5 fluorescence occurred. Higher analyte concentrations led to a progressive binding of the analyte to the antibody binding sites. The increased Cy5 fluorescence was determined by using a scanning laser-induced fluorescence detector. The limit of detection (LOD), using an antibody concentration of 20 nM, was 0.32 microg/L, or 1.11 x 10(-16) mol of simazine. In comparison, the LOD of the 96-well microtiter-plate-based ET immunoassay (micro-ETIA) was 0.15 microg/L, or 1.87 x 10(-13) mol. The LOD of the optimized micro-ETIA at 1 nM IgG, was 0.01 microg/L.

  18. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2014-06-03

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  19. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2015-09-29

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  20. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  1. Phobos Sample Return: Next Approach

    NASA Astrophysics Data System (ADS)

    Zelenyi, Lev; Martynov, Maxim; Zakharov, Alexander; Korablev, Oleg; Ivanov, Alexey; Karabadzak, George

    possible scenario of the Boomerang mission includes the approach to Deimos prior to the landing of Phobos. The needed excess ΔV w.r.t. simple scenario (elliptical orbit à near-Phobos orbit) amounts to 0.67 km s-1 (1.6 vs 0.93 km s-1). The Boomerang mission basically repeats the Phobos-SR (2011) architecture, where the transfer-orbiting spacecraft lands on the Phobos surface and a small return vehicle launches the return capsule to Earth. We consider the Boomerang mission as an important step in Mars exploration and a direct precursor of Mars Sample Return. The following elements of the Boomerang mission might be directly employed, or serve as the prototypes for the Mars Sample return in future: Return vehicle, Earth descent module, Transfer-orbital spacecraft. We urge the development of this project for its high science value and recognize its elements as potential national contribution to an international Mars Sample Return project. Galimov E.M., Phobos sample return mission: scientific substantiation, Solar System Res., v.44, No.1, pp5-14, 2010. Chappaz L., H.J. Melosh, M. Vaguero, and K.C. Howell, Material transfer from the surface of Mars to Phobos and Deimos, 43rd Lunar and planetary Science Conference, paper 1422, 2012.

  2. Efficient and Adaptive Methods for Computing Accurate Potential Surfaces for Quantum Nuclear Effects: Applications to Hydrogen-Transfer Reactions.

    PubMed

    DeGregorio, Nicole; Iyengar, Srinivasan S

    2018-01-09

    We present two sampling measures to gauge critical regions of potential energy surfaces. These sampling measures employ (a) the instantaneous quantum wavepacket density, an approximation to the (b) potential surface, its (c) gradients, and (d) a Shannon information theory based expression that estimates the local entropy associated with the quantum wavepacket. These four criteria together enable a directed sampling of potential surfaces that appears to correctly describe the local oscillation frequencies, or the local Nyquist frequency, of a potential surface. The sampling functions are then utilized to derive a tessellation scheme that discretizes the multidimensional space to enable efficient sampling of potential surfaces. The sampled potential surface is then combined with four different interpolation procedures, namely, (a) local Hermite curve interpolation, (b) low-pass filtered Lagrange interpolation, (c) the monomial symmetrization approximation (MSA) developed by Bowman and co-workers, and (d) a modified Shepard algorithm. The sampling procedure and the fitting schemes are used to compute (a) potential surfaces in highly anharmonic hydrogen-bonded systems and (b) study hydrogen-transfer reactions in biogenic volatile organic compounds (isoprene) where the transferring hydrogen atom is found to demonstrate critical quantum nuclear effects. In the case of isoprene, the algorithm discussed here is used to derive multidimensional potential surfaces along a hydrogen-transfer reaction path to gauge the effect of quantum-nuclear degrees of freedom on the hydrogen-transfer process. Based on the decreased computational effort, facilitated by the optimal sampling of the potential surfaces through the use of sampling functions discussed here, and the accuracy of the associated potential surfaces, we believe the method will find great utility in the study of quantum nuclear dynamics problems, of which application to hydrogen-transfer reactions and hydrogen

  3. Setting up equine embryo gender determination by preimplantation genetic diagnosis in a commercial embryo transfer program.

    PubMed

    Herrera, C; Morikawa, M I; Bello, M B; von Meyeren, M; Centeno, J Eusebio; Dufourq, P; Martinez, M M; Llorente, J

    2014-03-15

    Preimplantation genetic diagnosis (PGD) allows identifying genetic traits in early embryos. Because in some equine breeds, like Polo Argentino, females are preferred to males for competition, PGD can be used to determine the gender of the embryo before transfer and thus allow the production of only female pregnancies. This procedure could have a great impact on commercial embryo production programs. The present study was conducted to adapt gender selection by PGD to a large-scale equine embryo transfer program. To achieve this, we studied (i) the effect on pregnancy rates of holding biopsied embryos for 7 to 10 hours in holding medium at 32 °C before transfer, (ii) the effect on pregnancy rates of using embryos of different sizes for biopsy, and (iii) the efficiency of amplification by heating biopsies before polymerase chain reaction. Equine embryos were classified by size (≤300, 300-1000, and >1000 μm), biopsied, and transferred 1 to 2 or 7 to 10 hours after flushing. Some of the biopsy samples obtained were incubated for 10 minutes at 95 °C and the rest remained untreated. Pregnancy rates were recorded at 25 days of gestation; fetal gender was determined using ultrasonography and compared with PGD results. Holding biopsied embryos for 7 to 10 hours before transfer produced pregnancy rates similar to those for biopsied embryos transferred within 2 hours (63% and 57%, respectively). These results did not differ from pregnancy rates of nonbiopsied embryos undergoing the same holding times (50% for 7-10 hours and 63% for 1-2 hours). Pregnancy rates for biopsied and nonbiopsied embryos did not differ between size groups or between biopsied and nonbiopsied embryos within the same size group (P > 0.05). Incubating biopsy samples for 10 minutes at 95 °C before polymerase chain reaction significantly increased the diagnosis rate (78.5% vs. 45.5% for treated and nontreated biopsy samples respectively). Gender determination using incubated biopsy samples matched the

  4. Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer

    NASA Astrophysics Data System (ADS)

    Gran, R.; Betancourt, M.; Elkins, M.; Rodrigues, P. A.; Akbar, F.; Aliaga, L.; Andrade, D. A.; Bashyal, A.; Bellantoni, L.; Bercellie, A.; Bodek, A.; Bravar, A.; Budd, H.; Vera, G. F. R. Caceres; Cai, T.; Carneiro, M. F.; Coplowe, D.; da Motta, H.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Gallagher, H.; Ghosh, A.; Haider, H.; Han, J. Y.; Harris, D. A.; Henry, S.; Jena, D.; Kleykamp, J.; Kordosky, M.; Le, T.; Leistico, J. R.; Lovlein, A.; Lu, X.-G.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Nguyen, C.; Norrick, A.; Nuruzzaman, Olivier, A.; Paolone, V.; Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Ruterbories, D.; Schellman, H.; Salinas, C. J. Solano; Su, H.; Sultana, M.; Falero, S. Sánchez; Valencia, E.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; Minerva Collaboration

    2018-06-01

    We report on multinucleon effects in low momentum transfer (<0.8 GeV /c ) antineutrino interactions on plastic (CH) scintillator. These data are from the 2010-2011 antineutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well described when a screening effect at a low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasielastic, Δ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this antineutrino sample. We present the results as a double-differential cross section to accelerate the investigation of alternate models for antineutrino scattering off nuclei.

  5. Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer.

    PubMed

    Gran, R; Betancourt, M; Elkins, M; Rodrigues, P A; Akbar, F; Aliaga, L; Andrade, D A; Bashyal, A; Bellantoni, L; Bercellie, A; Bodek, A; Bravar, A; Budd, H; Vera, G F R Caceres; Cai, T; Carneiro, M F; Coplowe, D; da Motta, H; Dytman, S A; Díaz, G A; Felix, J; Fields, L; Fine, R; Gallagher, H; Ghosh, A; Haider, H; Han, J Y; Harris, D A; Henry, S; Jena, D; Kleykamp, J; Kordosky, M; Le, T; Leistico, J R; Lovlein, A; Lu, X-G; Maher, E; Manly, S; Mann, W A; Marshall, C M; McFarland, K S; McGowan, A M; Messerly, B; Miller, J; Mislivec, A; Morfín, J G; Mousseau, J; Naples, D; Nelson, J K; Nguyen, C; Norrick, A; Nuruzzaman; Olivier, A; Paolone, V; Patrick, C E; Perdue, G N; Ramírez, M A; Ransome, R D; Ray, H; Ren, L; Rimal, D; Ruterbories, D; Schellman, H; Salinas, C J Solano; Su, H; Sultana, M; Falero, S Sánchez; Valencia, E; Wolcott, J; Wospakrik, M; Yaeggy, B

    2018-06-01

    We report on multinucleon effects in low momentum transfer (<0.8  GeV/c) antineutrino interactions on plastic (CH) scintillator. These data are from the 2010-2011 antineutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well described when a screening effect at a low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasielastic, Δ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this antineutrino sample. We present the results as a double-differential cross section to accelerate the investigation of alternate models for antineutrino scattering off nuclei.

  6. TRANSFER OF AVERSIVE RESPONDENT ELICITATION IN ACCORDANCE WITH EQUIVALENCE RELATIONS

    PubMed Central

    Valverde, Miguel RodrÍguez; Luciano, Carmen; Barnes-Holmes, Dermot

    2009-01-01

    The present study investigates the transfer of aversively conditioned respondent elicitation through equivalence classes, using skin conductance as the measure of conditioning. The first experiment is an attempt to replicate Experiment 1 in Dougher, Augustson, Markham, Greenway, and Wulfert (1994), with different temporal parameters in the aversive conditioning procedure employed. Match-to-sample procedures were used to teach 17 participants two 4-member equivalence classes. Then, one member of one class was paired with electric shock and one member of the other class was presented without shock. The remaining stimuli from each class were presented in transfer tests. Unlike the findings in the original study, transfer of conditioning was not achieved. In Experiment 2, similar procedures were used with 30 participants, although several modifications were introduced (formation of five-member classes, direct conditioning with several elements of each class, random sequences of stimulus presentation in transfer tests, reversal in aversive conditioning contingencies). More than 80% of participants who had shown differential conditioning also showed the transfer of function effect. Moreover, this effect was replicated within subjects for 3 participants. This is the first demonstration of the transfer of aversive respondent elicitation through stimulus equivalence classes with the presentation of transfer test trials in random order. The latter prevents the possibility that transfer effects are an artefact of transfer test presentation order. PMID:20119523

  7. Effect of acoustic streaming on the mass transfer from a sublimating sphere

    NASA Astrophysics Data System (ADS)

    Kawahara, N.; Yarin, A. L.; Brenn, G.; Kastner, O.; Durst, F.

    2000-04-01

    The effect of the acoustic streaming on the mass transfer from the surface of a sphere positioned in an ultrasonic acoustic levitator is studied both experimentally and theoretically. Acoustic levitation using standing ultrasonic waves is an experimental tool for studying the heat and mass transfer from small solid or liquid samples, because it allows an almost steady positioning of a sample at a fixed location in space. However, the levitator introduces some difficulties. One of the main problems with acoustic levitation is that an acoustic streaming is induced near the sample surface, which affects the heat and mass transfer rates, as characterized by increased Nusselt and Sherwood numbers. The transfer rates are not uniform along the sample surface, and the aim of the present study is to quantify the spatial Sherwood number distribution over the surface of a sphere. The experiments are based on the measurement of the surface shape of a sphere layered with a solid substance as a function of time using a charge-coupled device (CCD) camera with backlighting. The sphere used in this research is a glass sphere layered with a volatile solid substance (naphthalene or camphor). The local mass transfer from the surface both with and without an ultrasonic acoustic field is investigated in order to evaluate the effect of the acoustic streaming. The experimental results are compared with predictions following from the theory outlined [A. L. Yarin, M. Pfaffenlehner, and C. Tropea, J. Fluid Mech. 356, 65 (1998); A. L. Yarin, G. Brenn, O. Kastner, D. Rensink, and C. Tropea, ibid. 399, 151 (1999)] which describes the acoustic field and the resulting acoustic streaming, and the mass transfer at the surface of particles and droplets located in an acoustic levitator. The results are also compared with the experimental data and with the theoretical predictions of Burdukov and Nakoryakov [J. Appl. Mech. Tech. Phys. 6, 51 (1965)], which are valid only in the case of spherical

  8. "Transfer Shock" or "Transfer Ecstasy?"

    ERIC Educational Resources Information Center

    Nickens, John M.

    The alleged characteristic drop in grade point average (GPA) of transfer students and the subsequent rise in GPA was investigated in this study. No statistically significant difference was found in first term junior year GPA between junior college transfers and native Florida State University students after the variance accounted for by the…

  9. HYDROLYSIS OF MTBE IN GROUND WATER SAMPLES PRESERVED WITIH HYDROCHLORIC ACID

    EPA Science Inventory

    Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as TBA. Because alcohols tend to stay with the water samples, they are not efficiently transferred to the gas chromatograph for separation and analysis. A common tec...

  10. Technology transfer

    NASA Technical Reports Server (NTRS)

    Handley, Thomas

    1992-01-01

    The requirements for a successful technology transfer program and what such a program would look like are discussed. In particular, the issues associated with technology transfer in general, and within the Jet Propulsion Laboratory (JPL) environment specifically are addressed. The section on background sets the stage, identifies the barriers to successful technology transfer, and suggests actions to address the barriers either generally or specifically. The section on technology transfer presents a process with its supporting management plan that is required to ensure a smooth transfer process. Viewgraphs are also included.

  11. Arabidopsis thalianafrom Polarization Transfer Solid-State NMR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Paul B; Wang, Tuo; Park, Yong Bum

    2014-07-23

    Polysaccharide-rich plant cell walls are hydrated under functional conditions, but the molecular interactions between water and polysaccharides in the wall have not been investigated. In this work, we employ polarization transfer solid-state NMR techniques to study the hydration of primary-wall polysaccharides of the model plant, Arabidopsis thaliana. By transferring water 1H polarization to polysaccharides through distance- and mobility-dependent 1H–1H dipolar couplings and detecting it through polysaccharide 13C signals, we obtain information about water proximity to cellulose, hemicellulose, and pectins as well as water mobility. Both intact and partially extracted cell wall samples are studied. Our results show that water–pectin polarizationmore » transfer is much faster than water–cellulose polarization transfer in all samples, but the extent of extraction has a profound impact on the water–polysaccharide spin diffusion. Removal of calcium ions and the consequent extraction of homogalacturonan (HG) significantly slowed down spin diffusion, while further extraction of matrix polysaccharides restored the spin diffusion rate. These trends are observed in cell walls with similar water content, thus they reflect inherent differences in the mobility and spatial distribution of water. Combined with quantitative analysis of the polysaccharide contents, our results indicate that calcium ions and HG gelation increase the amount of bound water, which facilitates spin diffusion, while calcium removal disrupts the gel and gives rise to highly dynamic water, which slows down spin diffusion. The recovery of spin diffusion rates after more extensive extraction is attributed to increased water-exposed surface areas of the polysaccharides. Water–pectin spin diffusion precedes water–cellulose spin diffusion, lending support to the single-network model of plant primary walls in which a substantial fraction of the cellulose surface is surrounded by pectins.« less

  12. The implications of shedder status and background DNA on direct and secondary transfer in an attack scenario.

    PubMed

    Fonneløp, Ane Elida; Ramse, Merete; Egeland, Thore; Gill, Peter

    2017-07-01

    In court questions are often raised related to how trace DNA was deposited, directly during the crime or innocently for instance by secondary transfer. It is therefore of interest to have knowledge of the probability of transfer or secondary transfer in different situations. Factors that could influence transfer probabilities are background DNA and the shedder status of the involved persons. In this study, we have classified participants as high or low DNA shedders. We observed DNA transfer in a simulated attack scenario, and demonstrated that shedder status has a significant influence of transfer rates. We have examined the background DNA in samples from T-shirts worn in an area with frequent human traffic and detected multiple contributors. We further demonstrated that DNA from co-workers of a T-shirt wearer can be secondarily transferred from the environment and detected in samples, and that the composition of background DNA is correlated with the shedder status of the wearer. Finally, we have illustrated the inference with the results of transfer probabilities and a fictive case with the use of a Bayesian network. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantitative and Qualitative Aspects of Gas-Metal-Oxide Mass Transfer in High-Temperature Confocal Scanning Laser Microscopy

    NASA Astrophysics Data System (ADS)

    Piva, Stephano P. T.; Pistorius, P. Chris; Webler, Bryan A.

    2018-05-01

    During high-temperature confocal scanning laser microscopy (HT-CSLM) of liquid steel samples, thermal Marangoni flow and rapid mass transfer between the sample and its surroundings occur due to the relatively small sample size (diameter around 5 mm) and large temperature gradients. The resulting evaporation and steel-slag reactions tend to change the chemical composition in the metal. Such mass transfer effects can change observed nonmetallic inclusions. This work quantifies oxide-metal-gas mass transfer of solutes during HT-CSLM experiments using computational simulations and experimental data for (1) dissolution of MgO inclusions in the presence and absence of slag and (2) Ca, Mg-silicate inclusion changes upon exposure of a Si-Mn-killed steel to an oxidizing gas atmosphere.

  14. Toddlers' word learning and transfer from electronic and print books.

    PubMed

    Strouse, Gabrielle A; Ganea, Patricia A

    2017-04-01

    Transfer from symbolic media to the real world can be difficult for young children. A sample of 73 toddlers aged 17 to 23months were read either an electronic book displayed on a touchscreen device or a traditional print book in which a novel object was paired with a novel label. Toddlers in both conditions learned the label within the context of the book. However, only those who read the traditional format book generalized and transferred the label to other contexts. An older group of 28 toddlers aged 24 to 30months did generalize and transfer from the electronic book. Across ages, those children who primarily used screens to watch prerecorded video at home transferred less from the electronic book than those with more diverse home media experiences. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Multi-spectrometer calibration transfer based on independent component analysis.

    PubMed

    Liu, Yan; Xu, Hao; Xia, Zhenzhen; Gong, Zhiyong

    2018-02-26

    Calibration transfer is indispensable for practical applications of near infrared (NIR) spectroscopy due to the need for precise and consistent measurements across different spectrometers. In this work, a method for multi-spectrometer calibration transfer is described based on independent component analysis (ICA). A spectral matrix is first obtained by aligning the spectra measured on different spectrometers. Then, by using independent component analysis, the aligned spectral matrix is decomposed into the mixing matrix and the independent components of different spectrometers. These differing measurements between spectrometers can then be standardized by correcting the coefficients within the independent components. Two NIR datasets of corn and edible oil samples measured with three and four spectrometers, respectively, were used to test the reliability of this method. The results of both datasets reveal that spectra measurements across different spectrometers can be transferred simultaneously and that the partial least squares (PLS) models built with the measurements on one spectrometer can predict that the spectra can be transferred correctly on another.

  16. Interfacility transfers for US ischemic stroke and TIA, 2006-2014.

    PubMed

    George, Benjamin P; Doyle, Sara J; Albert, George P; Busza, Ania; Holloway, Robert G; Sheth, Kevin N; Kelly, Adam G

    2018-05-01

    To investigate changes in emergency department (ED) transfers for ischemic stroke (IS) and TIA. We performed a retrospective observational study using the US Nationwide Emergency Department Sample to identify changes in interfacility ED transfers for IS and TIA from the perspective of the transferring ED (2006-2014). We calculated nationwide transfer rates and individual ED transfer rates for IS/TIA by diagnosis and hospital characteristics. Hospital-level fractional logistic regression examined changes in transfer rates over time. The population-estimated number of transfers for IS/TIA increased from 22,576 patient visits in 2006 to 54,485 patient visits in 2014 ( p trend < 0.001). The rate of IS/TIA transfer increased from 3.4 (95% confidence interval [CI] 3.0-3.8) in 2006 to 7.6 (95% CI 7.2-7.9) in 2014 per 100 ED visits. Among individual EDs, mean transfer rates for IS/TIA increased from 8.2 per 100 ED visits (median 2.0, interquartile range [IQR] 0-10.2) to 19.4 per 100 ED visits (median 8.1, IQR 1.1-33.3) (2006-2014) ( p trend < 0.001). Transfers were more common among IS. Transfer rates were greatest among rural (adjusted odds ratio [AOR] 3.05, 95% CI 2.56-3.64) vs urban/teaching and low-volume EDs (AOR 7.49, 95% CI 6.58-8.53, 1st vs 4th quartile). The adjusted odds of transfer for IS/TIA increased threefold (2006-2014). Interfacility ED transfers for IS/TIA more than doubled from 2006 to 2014. Further work should determine the necessity of IS/TIA transfers and seek to optimize the US stroke care system. © 2018 American Academy of Neurology.

  17. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, A. A.; Hesjedal, T.; Diamond Light Source, Didcot OX11 0DE

    We present a miniaturized molecular beam epitaxy (miniMBE) system with an outer diameter of 206 mm, optimized for flexible and high-throughput operation. The three-chamber system, used here for oxide growth, consists of a sample loading chamber, a storage chamber, and a growth chamber. The growth chamber is equipped with eight identical effusion cell ports with linear shutters, one larger port for either a multi-pocket electron beam evaporator or an oxygen plasma source, an integrated cryoshroud, retractable beam-flux monitor or quartz-crystal microbalance, reflection high energy electron diffraction, substrate manipulator, main shutter, and quadrupole mass spectrometer. The system can be combined withmore » ultrahigh vacuum (UHV) end stations on synchrotron and neutron beamlines, or equivalently with other complex surface analysis systems, including low-temperature scanning probe microscopy systems. Substrate handling is compatible with most UHV surface characterization systems, as the miniMBE can accommodate standard surface science sample holders. We introduce the design of the system, and its specific capabilities and operational parameters, and we demonstrate the epitaxial thin film growth of magnetoelectric Cr{sub 2}O{sub 3} on c-plane sapphire and ferrimagnetic Fe{sub 3}O{sub 4} on MgO (001)« less

  19. Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pincelli, T., E-mail: pincelli@iom.cnr.it; Rossi, G.; Laboratorio TASC, IOM-CNR, S.S. 14 km 163.5, Basovizza, 34149 Trieste

    2016-03-15

    ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric andmore » magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).« less

  20. Status of Sample Return Propulsion Technology Development Under NASA's ISPT Program

    NASA Technical Reports Server (NTRS)

    Anderson, David J.; Glaab, Louis J.; Munk, Michelle M.; Pencil, Eric; Dankanich, John; Peterson, Todd T.

    2012-01-01

    The In-Space Propulsion Technology (ISPT) program was tasked in 2009 to start development of propulsion technologies that would enable future sample return missions. ISPT s sample return technology development areas are diverse. Sample Return Propulsion (SRP) addresses electric propulsion for sample return and low cost Discovery-class missions, propulsion systems for Earth Return Vehicles (ERV) including transfer stages to the destination, and low technology readiness level (TRL) advanced propulsion technologies. The SRP effort continues work on HIVHAC thruster development to transition into developing a Hall-effect propulsion system for sample return (ERV and transfer stages) and low-cost missions. Previous work on the lightweight propellant-tanks continues for sample return with direct applicability to a Mars Sample Return (MSR) mission with general applicability to all future planetary spacecraft. The Earth Entry Vehicle (EEV) work focuses on building a fundamental base of multi-mission technologies for Earth Entry Vehicles (MMEEV). The main focus of the Planetary Ascent Vehicles (PAV) area is technology development for the Mars Ascent Vehicle (MAV), which builds upon and leverages the past MAV analysis and technology developments from the Mars Technology Program (MTP) and previous MSR studies

  1. 10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...

  2. 10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...

  3. VCCS Transfer Project: Transfer Rates, Transfer Performance, and Baccalaureate Completion.

    ERIC Educational Resources Information Center

    McHewitt, Earl R.; Taylor, Garry

    This document analyzes a study done by the Center for the Study of Community Colleges (CSCC), which examined transfer rates in the VCCS. The document provides definitions for transfer rate, academic performance, and completion rate as they are used in the study. The study answers the following questions: (1) which pool of students were used in the…

  4. Near-field radiative heat transfer in scanning thermal microscopy computed with the boundary element method

    NASA Astrophysics Data System (ADS)

    Nguyen, K. L.; Merchiers, O.; Chapuis, P.-O.

    2017-11-01

    We compute the near-field radiative heat transfer between a hot AFM tip and a cold substrate. This contribution to the tip-sample heat transfer in Scanning Thermal Microscopy is often overlooked, despite its leading role when the tip is out of contact. For dielectrics, we provide power levels exchanged as a function of the tip-sample distance in vacuum and spatial maps of the heat flux deposited into the sample which indicate the near-contact spatial resolution. The results are compared to analytical expressions of the Proximity Flux Approximation. The numerical results are obtained by means of the Boundary Element Method (BEM) implemented in the SCUFF-EM software, and require first a thorough convergence analysis of the progressive implementation of this method to the thermal emission by a sphere, the radiative transfer between two spheres, and the radiative exchange between a sphere and a finite substrate.

  5. Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials

    NASA Technical Reports Server (NTRS)

    Perez, Jose M.

    1996-01-01

    We present a summary of the research, citations of publications resulting from the research and abstracts of such publications. We have made no inventions in the performance of the work in this project. The main goals of the project were to set up a Chemical Vapor Deposition (CVD) diamond growth system attached to an UltraHigh Vacuum (UHV) atomic resolution Scanning Tunneling Microscopy (STM) system and carry out experiments aimed at studying the properties and growth of diamond films using atomic resolution UHV STM. We successfully achieved these goals. We observed, for the first time, the atomic structure of the surface of CVD grown epitaxial diamond (100) films using UHV STM. We studied the effects of atomic hydrogen on the CVD diamond growth process. We studied the electronic properties of the diamond (100) (2x1) surface, and the effect of alkali metal adsorbates such as Cs on the work function of this surface using UHV STM spectroscopy techniques. We also studied, using STM, new electronic materials such as carbon nanotubes and gold nanostructures. This work resulted in four publications in refereed scientific journals and five publications in refereed conference proceedings.

  6. Mars sample return mission architectures utilizing low thrust propulsion

    NASA Astrophysics Data System (ADS)

    Derz, Uwe; Seboldt, Wolfgang

    2012-08-01

    The Mars sample return mission is a flagship mission within ESA's Aurora program and envisioned to take place in the timeframe of 2020-2025. Previous studies developed a mission architecture consisting of two elements, an orbiter and a lander, each utilizing chemical propulsion and a heavy launcher like Ariane 5 ECA. The lander transports an ascent vehicle to the surface of Mars. The orbiter performs a separate impulsive transfer to Mars, conducts a rendezvous in Mars orbit with the sample container, delivered by the ascent vehicle, and returns the samples back to Earth in a small Earth entry capsule. Because the launch of the heavy orbiter by Ariane 5 ECA makes an Earth swing by mandatory for the trans-Mars injection, its total mission time amounts to about 1460 days. The present study takes a fresh look at the subject and conducts a more general mission and system analysis of the space transportation elements including electric propulsion for the transfer. Therefore, detailed spacecraft models for orbiters, landers and ascent vehicles are developed. Based on that, trajectory calculations and optimizations of interplanetary transfers, Mars entries, descents and landings as well as Mars ascents are carried out. The results of the system analysis identified electric propulsion for the orbiter as most beneficial in terms of launch mass, leading to a reduction of launch vehicle requirements and enabling a launch by a Soyuz-Fregat into GTO. Such a sample return mission could be conducted within 1150-1250 days. Concerning the lander, a separate launch in combination with electric propulsion leads to a significant reduction of launch vehicle requirements, but also requires a large number of engines and correspondingly a large power system. Therefore, a lander performing a separate chemical transfer could possibly be more advantageous. Alternatively, a second possible mission architecture has been developed, requiring only one heavy launch vehicle (e.g., Proton). In that

  7. Tip-Enhanced Photoinduced Electron Transfer and Ionization on Vertical Silicon Nanowires.

    PubMed

    Chen, Xiaoming; Wang, Tao; Lin, Leimiao; Wo, Fangjie; Liu, Yaqin; Liang, Xiao; Ye, Hui; Wu, Jianmin

    2018-05-02

    Nanostructured semiconductors are one of the most potent candidates for matrix-free laser desorption/ionization mass spectrometric (LDI-MS) analysis of low-molecular-weight molecules. Herein, the enhanced photoinduced electron transfer and LDI on the tip of a vertical silicon nanowire (SiNW) array were investigated. Theoretical simulation and LDI detection of indigo and isatin molecules in negative ion mode revealed that the electric field can be enhanced on the tip end of SiNWs, thereby promoting the energy and electron transfer to the analytes adsorbed on the tip of SiNWs. On the basis of this finding, a tip-contact sampling method coupled with LDI-MS detection was established. In this strategy, the tip of SiNWs can be regarded as microextraction heads for the sampling of molecules when they come in contact with analytes. Impression of skin, tissue, and pericarp on the vertical SiNW array can effectively transfer endogenous metabolites or exogenous substances onto the tip. Upon laser irradiation, the adsorbed molecules on the SiNW tip can be efficiently ionized and detected in negative ion mode because of the tip-enhanced electron transfer and LDI effect. We believe this work may significantly expand the application of LDI-MS in various fields.

  8. Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gran, R.; Betancourt, M.; Elkins, M.

    We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less

  9. Antineutrino Charged-Current Reactions on Hydrocarbon with Low Momentum Transfer

    DOE PAGES

    Gran, R.; Betancourt, M.; Elkins, M.; ...

    2018-06-01

    We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less

  10. Isolation, identification, and characterization of novel arenaviruses, the etiological agents of boid inclusion body disease.

    PubMed

    Hetzel, Udo; Sironen, Tarja; Laurinmäki, Pasi; Liljeroos, Lassi; Patjas, Aino; Henttonen, Heikki; Vaheri, Antti; Artelt, Annette; Kipar, Anja; Butcher, Sarah J; Vapalahti, Olli; Hepojoki, Jussi

    2013-10-01

    Boid inclusion body disease (BIBD) is a progressive, usually fatal disease of constrictor snakes, characterized by cytoplasmic inclusion bodies (IB) in a wide range of cell types. To identify the causative agent of the disease, we established cell cultures from BIBD-positive and -negative boa constrictors. The IB phenotype was maintained in cultured cells of affected animals, and supernatants from these cultures caused the phenotype in cultures originating from BIBD-negative snakes. Viruses were purified from the supernatants by ultracentrifugation and subsequently identified as arenaviruses. Purified virus also induced the IB phenotype in naive cells, which fulfilled Koch's postulates in vitro. One isolate, tentatively designated University of Helsinki virus (UHV), was studied in depth. Sequencing confirmed that UHV is a novel arenavirus species that is distinct from other known arenaviruses including those recently identified in snakes with BIBD. The morphology of UHV was established by cryoelectron tomography and subtomographic averaging, revealing the trimeric arenavirus spike structure at 3.2-nm resolution. Immunofluorescence, immunohistochemistry, and immunoblotting with a polyclonal rabbit antiserum against UHV and reverse transcription-PCR (RT-PCR) revealed the presence of genetically diverse arenaviruses in a large cohort of snakes with BIBD, confirming the causative role of arenaviruses. Some snakes were also found to carry arenavirus antibodies. Furthermore, mammalian cells (Vero E6) were productively infected with UHV, demonstrating the potential of arenaviruses to cross species barriers. In conclusion, we propose the newly identified lineage of arenaviruses associated with BIBD as a novel taxonomic entity, boid inclusion body disease-associated arenaviruses (BIBDAV), in the family Arenaviridae.

  11. Isolation, Identification, and Characterization of Novel Arenaviruses, the Etiological Agents of Boid Inclusion Body Disease

    PubMed Central

    Hetzel, Udo; Sironen, Tarja; Laurinmäki, Pasi; Liljeroos, Lassi; Patjas, Aino; Henttonen, Heikki; Vaheri, Antti; Artelt, Annette; Kipar, Anja; Butcher, Sarah J.; Vapalahti, Olli

    2013-01-01

    Boid inclusion body disease (BIBD) is a progressive, usually fatal disease of constrictor snakes, characterized by cytoplasmic inclusion bodies (IB) in a wide range of cell types. To identify the causative agent of the disease, we established cell cultures from BIBD-positive and -negative boa constrictors. The IB phenotype was maintained in cultured cells of affected animals, and supernatants from these cultures caused the phenotype in cultures originating from BIBD-negative snakes. Viruses were purified from the supernatants by ultracentrifugation and subsequently identified as arenaviruses. Purified virus also induced the IB phenotype in naive cells, which fulfilled Koch's postulates in vitro. One isolate, tentatively designated University of Helsinki virus (UHV), was studied in depth. Sequencing confirmed that UHV is a novel arenavirus species that is distinct from other known arenaviruses including those recently identified in snakes with BIBD. The morphology of UHV was established by cryoelectron tomography and subtomographic averaging, revealing the trimeric arenavirus spike structure at 3.2-nm resolution. Immunofluorescence, immunohistochemistry, and immunoblotting with a polyclonal rabbit antiserum against UHV and reverse transcription-PCR (RT-PCR) revealed the presence of genetically diverse arenaviruses in a large cohort of snakes with BIBD, confirming the causative role of arenaviruses. Some snakes were also found to carry arenavirus antibodies. Furthermore, mammalian cells (Vero E6) were productively infected with UHV, demonstrating the potential of arenaviruses to cross species barriers. In conclusion, we propose the newly identified lineage of arenaviruses associated with BIBD as a novel taxonomic entity, boid inclusion body disease-associated arenaviruses (BIBDAV), in the family Arenaviridae. PMID:23926354

  12. Estimating Dermal Transfer of Copper Particles from the ...

    EPA Pesticide Factsheets

    Lumber pressure-treated with micronized copper was examined for the release of copper and copper micro/nanoparticles using a surface wipe method to simulate dermal transfer. In 2003, the wood industry began replacing CCA treated lumber products for residential use with copper based formulations. Micronized copper (nano to micron sized particles) has become the preferred treatment formulation. There is a lack of information on the release of copper, the fate of the particles during dermal contact, and the copper exposure level to children from hand-to-mouth transfer. For the current study, three treated lumber products, two micronized copper and one ionic copper, were purchased from commercial retailers. The boards were left to weather outdoors for approximately 1 year. Over the year time period, hand wipe samples were collected periodically to determine copper transfer from the wood surfaces. The two micronized formulations and the ionic formulation released similar levels of total copper. The amount of copper released was high initially, but decreased to a constant level (~1.5 mg m-2) after the first month of outdoor exposure. Copper particles were identified on the sampling cloths during the first two months of the experiment, after which the levels of copper were insufficient to collect interpretable data. After 1 month, the particles exhibited minimal changes in shape and size. At the end of 2-months, significant deterioration of the particles was

  13. ASSEMBLY TRANSFER SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B. Gorpani

    2000-06-26

    The Assembly Transfer System (ATS) receives, cools, and opens rail and truck transportation casks from the Carrier/Cask Handling System (CCHS). The system unloads transportation casks consisting of bare Spent Nuclear Fuel (SNF) assemblies, single element canisters, and Dual Purpose Canisters (DPCs). For casks containing DPCs, the system opens the DPCs and unloads the SNF. The system stages the assemblies, transfer assemblies to and from fuel-blending inventory pools, loads them into Disposal Containers (DCs), temporarily seals and inerts the DC, decontaminates the DC and transfers it to the Disposal Container Handling System. The system also prepares empty casks and DPCs formore » off-site shipment. Two identical Assembly Transfer System lines are provided in the Waste Handling Building (WHB). Each line operates independently to handle the waste transfer throughput and to support maintenance operations. Each system line primarily consists of wet and dry handling areas. The wet handling area includes a cask transport system, cask and DPC preparation system, and a wet assembly handling system. The basket transport system forms the transition between the wet and dry handling areas. The dry handling area includes the dry assembly handling system, assembly drying system, DC preparation system, and DC transport system. Both the wet and dry handling areas are controlled by the control and tracking system. The system operating sequence begins with moving transportation casks to the cask preparation area. The cask preparation operations consist of cask cavity gas sampling, cask venting, cask cool-down, outer lid removal, and inner shield plug lifting fixture attachment. Casks containing bare SNF (no DPC) are filled with water and placed in the cask unloading pool. The inner shield plugs are removed underwater. For casks containing a DPC, the cask lid(s) is removed, and the DPC is penetrated, sampled, vented, and cooled. A DPC lifting fixture is attached and the cask is

  14. Tools to Study Interfaces for Superconducting, Thermoelectric, and Magnetic Materials at the University of Houston

    DTIC Science & Technology

    2016-09-01

    The MBE system, which grows crystalline thin films in ultrahigh vacuum (UHV) with precise control of thickness, composition, and morphology, will...used on our sputtering system to fabricate thin films with interfaces. - The electronic structures of these materials will be investigated using the...magnetization/transport measurements. The MBE system, which grows crystalline thin films in ultrahigh vacuum (UHV) with precise control of thickness, composition

  15. Working memory training in older adults: Bayesian evidence supporting the absence of transfer.

    PubMed

    Guye, Sabrina; von Bastian, Claudia C

    2017-12-01

    The question of whether working memory training leads to generalized improvements in untrained cognitive abilities is a longstanding and heatedly debated one. Previous research provides mostly ambiguous evidence regarding the presence or absence of transfer effects in older adults. Thus, to draw decisive conclusions regarding the effectiveness of working memory training interventions, methodologically sound studies with larger sample sizes are needed. In this study, we investigated whether or not a computer-based working memory training intervention induced near and far transfer in a large sample of 142 healthy older adults (65 to 80 years). Therefore, we randomly assigned participants to either the experimental group, which completed 25 sessions of adaptive, process-based working memory training, or to the active, adaptive visual search control group. Bayesian linear mixed-effects models were used to estimate performance improvements on the level of abilities, using multiple indicator tasks for near (working memory) and far transfer (fluid intelligence, shifting, and inhibition). Our data provided consistent evidence supporting the absence of near transfer to untrained working memory tasks and the absence of far transfer effects to all of the assessed abilities. Our results suggest that working memory training is not an effective way to improve general cognitive functioning in old age. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Sensitivity Equation Derivation for Transient Heat Transfer Problems

    NASA Technical Reports Server (NTRS)

    Hou, Gene; Chien, Ta-Cheng; Sheen, Jeenson

    2004-01-01

    The focus of the paper is on the derivation of sensitivity equations for transient heat transfer problems modeled by different discretization processes. Two examples will be used in this study to facilitate the discussion. The first example is a coupled, transient heat transfer problem that simulates the press molding process in fabrication of composite laminates. These state equations are discretized into standard h-version finite elements and solved by a multiple step, predictor-corrector scheme. The sensitivity analysis results based upon the direct and adjoint variable approaches will be presented. The second example is a nonlinear transient heat transfer problem solved by a p-version time-discontinuous Galerkin's Method. The resulting matrix equation of the state equation is simply in the form of Ax = b, representing a single step, time marching scheme. A direct differentiation approach will be used to compute the thermal sensitivities of a sample 2D problem.

  17. Phase transfer of 1- and 2-dimensional Cd-based nanocrystals

    NASA Astrophysics Data System (ADS)

    Kodanek, Torben; Banbela, Hadeel M.; Naskar, Suraj; Adel, Patrick; Bigall, Nadja C.; Dorfs, Dirk

    2015-11-01

    In this work, luminescent CdSe@CdS dot-in-rod nanocrystals, CdSe@CdS/ZnS nanorods as well as CdSe-CdS core-crown nanoplatelets were transferred into aqueous phase via ligand exchange reactions. For this purpose, bifunctional thiol-based ligands were employed, namely mercaptoacetic acid (MAA), 3-mercaptopropionic acid (MPA), 11-mercaptoundecanoic acid (MUA) as well as 2-(dimethylamino)ethanthiol (DMAET). Systematic investigations by means of photoluminescence quantum yield measurements as well as photoluminescence decay measurements have shown that the luminescence properties of the transferred nanostructures are affected by hole traps (induced by the thiol ligands themselves) as well as by spatial insulation and passivation against the environment. The influence of the tips of the nanorods on the luminescence is, however, insignificant. Accordingly, different ligands yield optimum results for different nanoparticle samples, mainly depending on the inorganic passivation of the respective samples. In case of CdSe@CdS nanorods, the highest emission intensities have been obtained by using short-chain ligands for the transfer preserving more than 50% of the pristine quantum yield of the hydrophobic nanorods. As opposed to this, the best possible quantum efficiency for the CdSe@CdS/ZnS nanorods has been achieved via MUA. The gained knowledge could be applied to transfer for the first time 2-dimensional CdSe-CdS core-crown nanoplatelets into water while preserving significant photoluminescence (up to 12% quantum efficiency).In this work, luminescent CdSe@CdS dot-in-rod nanocrystals, CdSe@CdS/ZnS nanorods as well as CdSe-CdS core-crown nanoplatelets were transferred into aqueous phase via ligand exchange reactions. For this purpose, bifunctional thiol-based ligands were employed, namely mercaptoacetic acid (MAA), 3-mercaptopropionic acid (MPA), 11-mercaptoundecanoic acid (MUA) as well as 2-(dimethylamino)ethanthiol (DMAET). Systematic investigations by means of

  18. Heat Transfer in High Temperature Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Miller, Steve D.; Cunnington, George R.

    2007-01-01

    High temperature multilayer insulations have been investigated as an effective component of thermal-protection systems for atmospheric re-entry of reusable launch vehicles. Heat transfer in multilayer insulations consisting of thin, gold-coated, ceramic reflective foils and Saffil(TradeMark) fibrous insulation spacers was studied both numerically and experimentally. A finite volume numerical thermal model using combined conduction (gaseous and solid) and radiation in porous media was developed. A two-flux model with anisotropic scattering was used for radiation heat transfer in the fibrous insulation spacers between the reflective foils. The thermal model was validated by comparison with effective thermal conductivity measurements in an apparatus based on ASTM standard C201. Measurements were performed at environmental pressures in the range from 1x10(exp -4) to 760 torr over the temperature range from 300 to 1300 K. Four multilayer samples with nominal densities of 48 kg/cu m were tested. The first sample was 13.3 mm thick and had four evenly spaced reflective foils. The other three samples were 26.6 mm thick and utilized either one, two, or four reflective foils, located near the hot boundary with nominal foil spacing of 1.7 mm. The validated thermal model was then used to study relevant design parameters, such as reflective foil spacing and location in the stack-up and coating of one or both sides of foils.

  19. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    PubMed

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

  20. Nonadiabatic rate constants for proton transfer and proton-coupled electron transfer reactions in solution: Effects of quadratic term in the vibronic coupling expansion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soudackov, Alexander V.; Hammes-Schiffer, Sharon

    2015-11-21

    Rate constant expressions for vibronically nonadiabatic proton transfer and proton-coupled electron transfer reactions are presented and analyzed. The regimes covered include electronically adiabatic and nonadiabatic reactions, as well as high-frequency and low-frequency proton donor-acceptor vibrational modes. These rate constants differ from previous rate constants derived with the cumulant expansion approach in that the logarithmic expansion of the vibronic coupling in terms of the proton donor-acceptor distance includes a quadratic as well as a linear term. The analysis illustrates that inclusion of this quadratic term in the framework of the cumulant expansion framework may significantly impact the rate constants at highmore » temperatures for proton transfer interfaces with soft proton donor-acceptor modes that are associated with small force constants and weak hydrogen bonds. The effects of the quadratic term may also become significant in these regimes when using the vibronic coupling expansion in conjunction with a thermal averaging procedure for calculating the rate constant. In this case, however, the expansion of the coupling can be avoided entirely by calculating the couplings explicitly for the range of proton donor-acceptor distances sampled. The effects of the quadratic term for weak hydrogen-bonding systems are less significant for more physically realistic models that prevent the sampling of unphysical short proton donor-acceptor distances. Additionally, the rigorous relation between the cumulant expansion and thermal averaging approaches is clarified. In particular, the cumulant expansion rate constant includes effects from dynamical interference between the proton donor-acceptor and solvent motions and becomes equivalent to the thermally averaged rate constant when these dynamical effects are neglected. This analysis identifies the regimes in which each rate constant expression is valid and thus will be important for future applications to

  1. Pragmatic Transfer.

    ERIC Educational Resources Information Center

    Kasper, Gabriele

    1992-01-01

    Attempting to clarify the concept of pragmatic transfer, this article proposes as a basic distinction Leech/Thomas' dichotomy of sociopragmatics versus pragmalinguistics, presenting evidence for transfer at both levels. Issues discussed include pragmatic universals in speech act realization, conditions for pragmatic transfer, communicative…

  2. Bacteria-Human Somatic Cell Lateral Gene Transfer Is Enriched in Cancer Samples

    PubMed Central

    Robinson, Kelly M.; White, James Robert; Ganesan, Ashwinkumar; Nourbakhsh, Syrus; Dunning Hotopp, Julie C.

    2013-01-01

    There are 10× more bacterial cells in our bodies from the microbiome than human cells. Viral DNA is known to integrate in the human genome, but the integration of bacterial DNA has not been described. Using publicly available sequence data from the human genome project, the 1000 Genomes Project, and The Cancer Genome Atlas (TCGA), we examined bacterial DNA integration into the human somatic genome. Here we present evidence that bacterial DNA integrates into the human somatic genome through an RNA intermediate, and that such integrations are detected more frequently in (a) tumors than normal samples, (b) RNA than DNA samples, and (c) the mitochondrial genome than the nuclear genome. Hundreds of thousands of paired reads support random integration of Acinetobacter-like DNA in the human mitochondrial genome in acute myeloid leukemia samples. Numerous read pairs across multiple stomach adenocarcinoma samples support specific integration of Pseudomonas-like DNA in the 5′-UTR and 3′-UTR of four proto-oncogenes that are up-regulated in their transcription, consistent with conversion to an oncogene. These data support our hypothesis that bacterial integrations occur in the human somatic genome and may play a role in carcinogenesis. We anticipate that the application of our approach to additional cancer genome projects will lead to the more frequent detection of bacterial DNA integrations in tumors that are in close proximity to the human microbiome. PMID:23840181

  3. Transfer Learning for Class Imbalance Problems with Inadequate Data.

    PubMed

    Al-Stouhi, Samir; Reddy, Chandan K

    2016-07-01

    A fundamental problem in data mining is to effectively build robust classifiers in the presence of skewed data distributions. Class imbalance classifiers are trained specifically for skewed distribution datasets. Existing methods assume an ample supply of training examples as a fundamental prerequisite for constructing an effective classifier. However, when sufficient data is not readily available, the development of a representative classification algorithm becomes even more difficult due to the unequal distribution between classes. We provide a unified framework that will potentially take advantage of auxiliary data using a transfer learning mechanism and simultaneously build a robust classifier to tackle this imbalance issue in the presence of few training samples in a particular target domain of interest. Transfer learning methods use auxiliary data to augment learning when training examples are not sufficient and in this paper we will develop a method that is optimized to simultaneously augment the training data and induce balance into skewed datasets. We propose a novel boosting based instance-transfer classifier with a label-dependent update mechanism that simultaneously compensates for class imbalance and incorporates samples from an auxiliary domain to improve classification. We provide theoretical and empirical validation of our method and apply to healthcare and text classification applications.

  4. Effect of air bubble localization after transfer on embryo transfer outcomes.

    PubMed

    Tiras, Bulent; Korucuoglu, Umit; Polat, Mehtap; Saltik, Ayse; Zeyneloglu, Hulusi Bulent; Yarali, Hakan

    2012-09-01

    Our study aimed to provide information about the effects of air bubble localization after transfer on embryo transfer outcomes. Retrospective analysis of 7489 ultrasound-guided embryo transfers. Group 1 included 6631 embryo transfers in which no movement of the air bubbles was observed after transfer. Group 2 consisted of 407 embryo transfers in which the air bubbles moved towards the uterine fundus spontaneously, a little time after transfer. Group 3 included 370 embryo transfers in which the air bubbles moved towards the uterine fundus with ejection, immediately after transfer. Group 4 consisted of 81 embryo transfers in which the air bubbles moved towards the cervical canal. The four patient groups were different from one another with respect to positive pregnancy tests. Post hoc test revealed that this difference was between group 4 and other groups. An initial finding of our study was significantly decreased positive pregnancy test rates and clinical pregnancy rates with air bubbles moving towards the cervical canal after transfer. Although air bubbles moving towards the uterine fundus with ejection were associated with higher pregnancy rates, higher miscarriage rates and similar live birth rates were observed compared to air bubbles remaining stable after transfer. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Understanding the Adult Transfer Student--Support, Concerns, and Transfer Student Capital

    ERIC Educational Resources Information Center

    Rosenberg, Michael J.

    2016-01-01

    This quantitative study of degree-seeking students in community college examines whether there are age-related differences in transfer intent, research on selection of a transfer destination, use of transfer-related services, and concerns about the transfer process, all of which are key aspects of the concept of transfer student capital. Students…

  6. Device and method for automated separation of a sample of whole blood into aliquots

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  7. Extensive domain motion and electron transfer in the human electron transferring flavoprotein.medium chain Acyl-CoA dehydrogenase complex.

    PubMed

    Toogood, Helen S; van Thiel, Adam; Basran, Jaswir; Sutcliffe, Mike J; Scrutton, Nigel S; Leys, David

    2004-07-30

    The crystal structure of the human electron transferring flavoprotein (ETF).medium chain acyl-CoA dehydrogenase (MCAD) complex reveals a dual mode of protein-protein interaction, imparting both specificity and promiscuity in the interaction of ETF with a range of structurally distinct primary dehydrogenases. ETF partitions the functions of partner binding and electron transfer between (i) the recognition loop, which acts as a static anchor at the ETF.MCAD interface, and (ii) the highly mobile redox active FAD domain. Together, these enable the FAD domain of ETF to sample a range of conformations, some compatible with fast interprotein electron transfer. Disorders in amino acid or fatty acid catabolism can be attributed to mutations at the protein-protein interface. Crucially, complex formation triggers mobility of the FAD domain, an induced disorder that contrasts with general models of protein-protein interaction by induced fit mechanisms. The subsequent interfacial motion in the MCAD.ETF complex is the basis for the interaction of ETF with structurally diverse protein partners. Solution studies using ETF and MCAD with mutations at the protein-protein interface support this dynamic model and indicate ionic interactions between MCAD Glu(212) and ETF Arg alpha(249) are likely to transiently stabilize productive conformations of the FAD domain leading to enhanced electron transfer rates between both partners.

  8. Development of the prototype pneumatic transfer system for ITER neutron activation system.

    PubMed

    Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  9. Cyclodextrin-enhanced extraction and energy transfer of carcinogens in complex oil environments.

    PubMed

    Serio, Nicole; Chanthalyma, Chitapom; Prignano, Lindsey; Levine, Mindy

    2013-11-27

    Reported herein is the use of γ-cyclodextrin for two tandem functions: (a) the extraction of carcinogenic polycyclic aromatic hydrocarbons (PAHs) from oil samples into aqueous solution and (b) the promotion of highly efficient energy transfer from the newly extracted PAHs to a high-quantum-yield fluorophore. The extraction proceeded in moderate to good efficiencies, and the resulting cyclodextrin-promoted energy transfer led to a new, brightly fluorescent signal in aqueous solution. The resulting dual-function system (extraction followed by energy transfer) has significant relevance in the environmental detection and cleanup of oil-spill-related carcinogens.

  10. Problems with multiple use of transfer buffer in protein electrophoretic transfer.

    PubMed

    Dorri, Yaser; Kurien, Biji T; Scofield, R Hal

    2010-04-01

    Two-dimensional gel electrophoresis (2DE) and SDS-PAGE are the two most useful methods in protein separation. Proteins separated by 2DE or SDS-PAGE are usually transferred to membranes using a variety of methods, such as electrophoretic transfer, heat-mediated transfer, or nonelectrophoretic transfer, for specific protein detection and/or analysis. In a recent study, Pettegrew et al. claim to reuse transfer buffer containing methanol for at least five times for transferring proteins from SDS-PAGE to polyvinylidene difluoride. They add 150-200 ml fresh transfer solution each time for extended use as a result of loss of transfer buffer. Finally, they test efficiency of each protein transfer by chemiluminescence detection. Here, we comment on this report, as we believe this method is not accurate and useful for protein analysis, and it can cause background binding as well as inaccurate protein analysis.

  11. 12 CFR 1005.36 - Transfers scheduled before the date of transfer.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of transfer. (a) Timing. (1) For a one-time transfer scheduled five or more business days before the... the timing requirements of that section. (b) Accuracy. (1) For a one-time transfer scheduled five or... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Transfers scheduled before the date of transfer...

  12. a Comparison of Two Strategies for Avoiding Negative Transfer in Domain Adaptation Based on Logistic Regression

    NASA Astrophysics Data System (ADS)

    Paul, A.; Vogt, K.; Rottensteiner, F.; Ostermann, J.; Heipke, C.

    2018-05-01

    In this paper we deal with the problem of measuring the similarity between training and tests datasets in the context of transfer learning (TL) for image classification. TL tries to transfer knowledge from a source domain, where labelled training samples are abundant but the data may follow a different distribution, to a target domain, where labelled training samples are scarce or even unavailable, assuming that the domains are related. Thus, the requirements w.r.t. the availability of labelled training samples in the target domain are reduced. In particular, if no labelled target data are available, it is inherently difficult to find a robust measure of relatedness between the source and target domains. This is of crucial importance for the performance of TL, because the knowledge transfer between unrelated data may lead to negative transfer, i.e. to a decrease of classification performance after transfer. We address the problem of measuring the relatedness between source and target datasets and investigate three different strategies to predict and, consequently, to avoid negative transfer in this paper. The first strategy is based on circular validation. The second strategy relies on the Maximum Mean Discrepancy (MMD) similarity metric, whereas the third one is an extension of MMD which incorporates the knowledge about the class labels in the source domain. Our method is evaluated using two different benchmark datasets. The experiments highlight the strengths and weaknesses of the investigated methods. We also show that it is possible to reduce the amount of negative transfer using these strategies for a TL method and to generate a consistent performance improvement over the whole dataset.

  13. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... measuring sample flows by designing a passive sampling system that meets the following requirements: (A) The... number of bends, and have no filters. (B) If probes are designed such that they are sensitive to stack... design and construction. Use sample probes with inside surfaces of 300 series stainless steel or, for raw...

  14. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measuring sample flows by designing a passive sampling system that meets the following requirements: (A) The... number of bends, and have no filters. (B) If probes are designed such that they are sensitive to stack... design and construction. Use sample probes with inside surfaces of 300 series stainless steel or, for raw...

  15. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... measuring sample flows by designing a passive sampling system that meets the following requirements: (A) The... number of bends, and have no filters. (B) If probes are designed such that they are sensitive to stack... design and construction. Use sample probes with inside surfaces of 300 series stainless steel or, for raw...

  16. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... measuring sample flows by designing a passive sampling system that meets the following requirements: (A) The... number of bends, and have no filters. (B) If probes are designed such that they are sensitive to stack... design and construction. Use sample probes with inside surfaces of 300 series stainless steel or, for raw...

  17. 40 CFR 1065.145 - Gaseous and PM probes, transfer lines, and sampling system components.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... measuring sample flows by designing a passive sampling system that meets the following requirements: (A) The... number of bends, and have no filters. (B) If probes are designed such that they are sensitive to stack... design and construction. Use sample probes with inside surfaces of 300 series stainless steel or, for raw...

  18. An abnormally slow proton transfer reaction in a simple HBO derivative due to ultrafast intramolecular-charge transfer events.

    PubMed

    Alarcos, Noemí; Gutierrez, Mario; Liras, Marta; Sánchez, Félix; Douhal, Abderrazzak

    2015-07-07

    We report on the steady-state, picosecond and femtosecond time-resolved studies of a charge and proton transfer dye 6-amino-2-(2'-hydroxyphenyl)benzoxazole (6A-HBO) and its methylated derivative 6-amino-2-(2'-methoxyphenyl)benzoxazole (6A-MBO), in different solvents. With femtosecond resolution and comparison with the photobehaviour of 6A-MBO, we demonstrate for 6A-HBO in solution, the photoproduction of an intramolecular charge-transfer (ICT) process at S1 taking place in ∼140 fs or shorter, followed by solvent relaxation in the charge transferred species. The generated structure (syn-enol charge transfer conformer) experiences an excited-state intramolecular proton-transfer (ESIPT) reaction to produce a keto-type tautomer. This subsequent proton motion occurs in 1.2 ps (n-heptane), 14 ps (DCM) and 35 ps (MeOH). In MeOH, it is assisted by the solvent molecules and occurs through tunneling for which we got a large kinetic isotope effect (KIE) of about 13. For the 6A-DBO (deuterated sample in CD3OD) the global proton-transfer reaction takes place in 200 ps, showing a remarkable slow KIE regime. The slow ESIPT reaction in DCM (14 ps), not through tunnelling as it is not sensitive to OH/OD exchange, has however to overcome an energy barrier using intramolecular as well as solvent coordinates. The rich ESIPT dynamics of 6A-HBO in the used solutions is governed by an ICT reaction, triggered by the amino group, and it is solvent dependent. Thus, the charge injection to a 6A-HBO molecular frame makes the ICT species more stable, and the phenol group less acidic, slowing down the subsequent ESIPT reaction. Our findings bring new insights into the coupling between ICT and ESIPT reactions on the potential-energy surfaces of several barriers.

  19. Discriminative Transfer Subspace Learning via Low-Rank and Sparse Representation.

    PubMed

    Xu, Yong; Fang, Xiaozhao; Wu, Jian; Li, Xuelong; Zhang, David

    2016-02-01

    In this paper, we address the problem of unsupervised domain transfer learning in which no labels are available in the target domain. We use a transformation matrix to transfer both the source and target data to a common subspace, where each target sample can be represented by a combination of source samples such that the samples from different domains can be well interlaced. In this way, the discrepancy of the source and target domains is reduced. By imposing joint low-rank and sparse constraints on the reconstruction coefficient matrix, the global and local structures of data can be preserved. To enlarge the margins between different classes as much as possible and provide more freedom to diminish the discrepancy, a flexible linear classifier (projection) is obtained by learning a non-negative label relaxation matrix that allows the strict binary label matrix to relax into a slack variable matrix. Our method can avoid a potentially negative transfer by using a sparse matrix to model the noise and, thus, is more robust to different types of noise. We formulate our problem as a constrained low-rankness and sparsity minimization problem and solve it by the inexact augmented Lagrange multiplier method. Extensive experiments on various visual domain adaptation tasks show the superiority of the proposed method over the state-of-the art methods. The MATLAB code of our method will be publicly available at http://www.yongxu.org/lunwen.html.

  20. The effect of the number of transferred embryos, the interval between nuclear transfer and embryo transfer, and the transfer pattern on pig cloning efficiency.

    PubMed

    Rim, Chol Ho; Fu, Zhixin; Bao, Lei; Chen, Haide; Zhang, Dan; Luo, Qiong; Ri, Hak Chol; Huang, Hefeng; Luan, Zhidong; Zhang, Yan; Cui, Chun; Xiao, Lei; Jong, Ui Myong

    2013-12-01

    To improve the efficiency of producing cloned pigs, we investigated the influence of the number of transferred embryos, the culturing interval between nuclear transfer (NT) and embryo transfer, and the transfer pattern (single oviduct or double oviduct) on cloning efficiency. The results demonstrated that transfer of either 150-200 or more than 200NT embryos compared to transfer of 100-150 embryos resulted in a significantly higher pregnancy rate (48 ± 16, 50 ± 16 vs. 29 ± 5%, p<0.05) and average litter size (4.1 ± 2.3, 7 ± 3.6 vs. 2.5 ± 0.5). In vitro culture of reconstructed embryos for a longer time (40 h vs. 20 h) resulted in higher (p<0.05) pregnancy rate (44 ± 9 vs. 31 ± 3%) and delivery rate (44 ± 9 vs. 25 ± 9%). Furthermore, double oviductal transfer dramatically increased pregnancy rate (83 ± 6 vs. 27+8%, p<0.05), delivery rate (75 ± 2 vs. 27+8%, p<0.05) and average litter size (6.5 ± 2.8 vs. 2.6 ± 1.2) compared to single oviductal transfer. Our study demonstrated that an improvement in pig cloning efficiency is achieved by adjusting the number and in vitro culture time of reconstructed embryos as well as the embryo transfer pattern. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. To transfer or not to transfer? Kinematics and laterality quotient predict interlimb transfer of motor learning

    PubMed Central

    Lefumat, Hannah Z.; Vercher, Jean-Louis; Miall, R. Chris; Cole, Jonathan; Buloup, Frank; Bringoux, Lionel; Bourdin, Christophe

    2015-01-01

    Humans can remarkably adapt their motor behavior to novel environmental conditions, yet it remains unclear which factors enable us to transfer what we have learned with one limb to the other. Here we tested the hypothesis that interlimb transfer of sensorimotor adaptation is determined by environmental conditions but also by individual characteristics. We specifically examined the adaptation of unconstrained reaching movements to a novel Coriolis, velocity-dependent force field. Right-handed subjects sat at the center of a rotating platform and performed forward reaching movements with the upper limb toward flashed visual targets in prerotation, per-rotation (i.e., adaptation), and postrotation tests. Here only the dominant arm was used during adaptation and interlimb transfer was assessed by comparing performance of the nondominant arm before and after dominant-arm adaptation. Vision and no-vision conditions did not significantly influence interlimb transfer of trajectory adaptation, which on average was significant but limited. We uncovered a substantial heterogeneity of interlimb transfer across subjects and found that interlimb transfer can be qualitatively and quantitatively predicted for each healthy young individual. A classifier showed that in our study, interlimb transfer could be predicted based on the subject's task performance, most notably motor variability during learning, and his or her laterality quotient. Positive correlations suggested that variability of motor performance and lateralization of arm movement control facilitate interlimb transfer. We further show that these individual characteristics can predict the presence and the magnitude of interlimb transfer of left-handers. Overall, this study suggests that individual characteristics shape the way the nervous system can generalize motor learning. PMID:26334018

  2. Factors influencing training transfer in nursing profession: a qualitative study.

    PubMed

    Ma, Fang; Bai, Yangjing; Bai, Yangjuan; Ma, Weiguang; Yang, Xiangyu; Li, Jiping

    2018-03-20

    There is a growing recognition that training is not translated into performance and the 'transfer problem' exists in organization training today. Although factors contributing to training transfer have been identified in business and industry, the factors influencing training transfer in nursing profession remain less clear. A qualitative descriptive study was undertaken in two tertiary referral hospitals in China from February 2013 to September 2013. Purposeful sampling of 24 nursing staffs were interviewed about the factors influencing training transfer. Seven themes evolved from the analysis, categorized in 4 main domains, which described the factors influencing training transfer in nursing profession in trainee characteristics, training design, work environment and profession domain. The trainee characteristics domain included attitude and ability. The training design domain included training content and instruction method. The work environment domain included supports as facilitators and opposition as hindrance. The theme pertaining to the profession domain was professional development. Health care managers need to understand the factors influencing training transfer for maximizing the benefits of training. The right beliefs and values about training, the rigorous employee selection for training, the relevance of training content, training instructions facilitating learning and transfer, supports from peer, supervisors and the organization, organizational culture such as change, sharing, learning and support, and professional development are key to successful training transfer. Furthermore, managers should be aware of the opposition from co-workers and find ways to prevent it.

  3. Ultrafast Interlayer Electron Transfer in Incommensurate Transition Metal Dichalcogenide Homobilayers.

    PubMed

    Li, Yuanyuan; Cui, Qiannan; Ceballos, Frank; Lane, Samuel D; Qi, Zeming; Zhao, Hui

    2017-11-08

    Two-dimensional materials, such as graphene, transition metal dichalcogenides, and phosphorene, can be used to construct van der Waals multilayer structures. This approach has shown potentials to produce new materials that combine novel properties of the participating individual layers. One key requirement for effectively harnessing emergent properties of these materials is electronic connection of the involved atomic layers through efficient interlayer charge or energy transfer. Recently, ultrafast charge transfer on a time scale shorter than 100 fs has been observed in several van der Waals bilayer heterostructures formed by two different materials. However, information on the transfer between two atomic layers of the same type is rare. Because these homobilayers are essential elements in constructing multilayer structures with desired optoelectronic properties, efficient interlayer transfer is highly desired. Here we show that electron transfer between two monolayers of MoSe 2 occurs on a picosecond time scale. Even faster transfer was observed in homobilayers of WS 2 and WSe 2 . The samples were fabricated by manually stacking two exfoliated monolayer flakes. By adding a graphene layer as a fast carrier recombination channel for one of the two monolayers, the transfer of the photoexcited carriers from the populated to the drained monolayers was time-resolved by femtosecond transient absorption measurements. The observed efficient interlayer carrier transfer indicates that such homobilayers can be used in van der Waals multilayers to enhance their optical absorption without significantly compromising the interlayer transport performance. Our results also provide valuable information for understanding interlayer charge transfer in heterostructures.

  4. Classifier transfer with data selection strategies for online support vector machine classification with class imbalance

    NASA Astrophysics Data System (ADS)

    Krell, Mario Michael; Wilshusen, Nils; Seeland, Anett; Kim, Su Kyoung

    2017-04-01

    Objective. Classifier transfers usually come with dataset shifts. To overcome dataset shifts in practical applications, we consider the limitations in computational resources in this paper for the adaptation of batch learning algorithms, like the support vector machine (SVM). Approach. We focus on data selection strategies which limit the size of the stored training data by different inclusion, exclusion, and further dataset manipulation criteria like handling class imbalance with two new approaches. We provide a comparison of the strategies with linear SVMs on several synthetic datasets with different data shifts as well as on different transfer settings with electroencephalographic (EEG) data. Main results. For the synthetic data, adding only misclassified samples performed astoundingly well. Here, balancing criteria were very important when the other criteria were not well chosen. For the transfer setups, the results show that the best strategy depends on the intensity of the drift during the transfer. Adding all and removing the oldest samples results in the best performance, whereas for smaller drifts, it can be sufficient to only add samples near the decision boundary of the SVM which reduces processing resources. Significance. For brain-computer interfaces based on EEG data, models trained on data from a calibration session, a previous recording session, or even from a recording session with another subject are used. We show, that by using the right combination of data selection criteria, it is possible to adapt the SVM classifier to overcome the performance drop from the transfer.

  5. Scanning tunneling microscopy studies of pulse deposition of dinuclear organometallic molecules on Au(111)

    NASA Astrophysics Data System (ADS)

    Guo, Song; Alex Kandel, S.

    2008-01-01

    Ultrahigh-vacuum scanning tunneling microscopy (STM) was used to study trans-[Cl(dppe)2Ru(CC)6Ru(dppe)2Cl] [abbreviated as Ru2, diphenylphosphinoethane (dppe)] on Au(111). This large organometallic molecule was pulse deposited onto the Au(111) surface under ultrahigh-vacuum (UHV) conditions. UHV STM studies on the prepared sample were carried out at room temperature and 77K in order to probe molecular adsorption and to characterize the surface produced by the pulse deposition process. Isolated Ru2 molecules were successfully imaged by STM at room temperature; however, STM images were degraded by mobile toluene solvent molecules that remain on the surface after the deposition. Cooling the sample to 77K allows the solvent molecules to be observed directly using STM, and under these conditions, toluene forms organized striped domains with regular domain boundaries and a lattice characterized by 5.3 and 2.7Å intermolecular distances. When methylene chloride is used as the solvent, it forms analogous domains on the surface at 77K. Mild annealing under vacuum causes most toluene molecules to desorb from the surface; however, this annealing process may lead to thermal degradation of Ru2 molecules. Although pulse deposition is an effective way to deposit molecules on surfaces, the presence of solvent on the surface after pulse deposition is unavoidable without thermal annealing, and this annealing may cause undesired chemical changes in the adsorbates under study. Preparation of samples using pulse deposition must take into account the characteristics of sample molecules, solvent, and surfaces.

  6. Camphor-Enabled Transfer and Mechanical Testing of Centimeter-Scale Ultrathin Films.

    PubMed

    Wang, Bin; Luo, Da; Li, Zhancheng; Kwon, Youngwoo; Wang, Meihui; Goo, Min; Jin, Sunghwan; Huang, Ming; Shen, Yongtao; Shi, Haofei; Ding, Feng; Ruoff, Rodney S

    2018-05-21

    Camphor is used to transfer centimeter-scale ultrathin films onto custom-designed substrates for mechanical (tensile) testing. Compared to traditional transfer methods using dissolving/peeling to remove the support-layers, camphor is sublimed away in air at low temperature, thereby avoiding additional stress on the as-transferred films. Large-area ultrathin films can be transferred onto hollow substrates without damage by this method. Tensile measurements are made on centimeter-scale 300 nm-thick graphene oxide film specimens, much thinner than the ≈2 μm minimum thickness of macroscale graphene-oxide films previously reported. Tensile tests were also done on two different types of large-area samples of adlayer free CVD-grown single-layer graphene supported by a ≈100 nm thick polycarbonate film; graphene stiffens this sample significantly, thus the intrinsic mechanical response of the graphene can be extracted. This is the first tensile measurement of centimeter-scale monolayer graphene films. The Young's modulus of polycrystalline graphene ranges from 637 to 793 GPa, while for near single-crystal graphene, it ranges from 728 to 908 GPa (folds parallel to the tensile loading direction) and from 683 to 775 GPa (folds orthogonal to the tensile loading direction), demonstrating the mechanical performance of large-area graphene in a size scale relevant to many applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Duplex sampling apparatus and method

    DOEpatents

    Brown, Paul E.; Lloyd, Robert

    1992-01-01

    An improved apparatus is provided for sampling a gaseous mixture and for measuring mixture components. The apparatus includes two sampling containers connected in series serving as a duplex sampling apparatus. The apparatus is adapted to independently determine the amounts of condensable and noncondensable gases in admixture from a single sample. More specifically, a first container includes a first port capable of selectively connecting to and disconnecting from a sample source and a second port capable of selectively connecting to and disconnecting from a second container. A second container also includes a first port capable of selectively connecting to and disconnecting from the second port of the first container and a second port capable of either selectively connecting to and disconnecting from a differential pressure source. By cooling a mixture sample in the first container, the condensable vapors form a liquid, leaving noncondensable gases either as free gases or dissolved in the liquid. The condensed liquid is heated to drive out dissolved noncondensable gases, and all the noncondensable gases are transferred to the second container. Then the first and second containers are separated from one another in order to separately determine the amount of noncondensable gases and the amount of condensable gases in the sample.

  8. Water pollutant fingerprinting tracks recent industrial transfer from coastal to inland China: A case study

    PubMed Central

    Zheng, Weiwei; Wang, Xia; Tian, Dajun; Jiang, Songhui; Andersen, Melvin E.; He, Genhsjeng; Crabbe, M. James C.; Zheng, Yuxin; Zhong, Yang; Qu, Weidong

    2013-01-01

    In recent years, China’s developed regions have transferred industries to undeveloped regions. Large numbers of unlicensed or unregistered enterprises are widespread in these undeveloped regions and they are subject to minimal regulation. Current methods for tracing industrial transfers in these areas, based on enterprise registration information or economic surveys, do not work. We have developed an analytical framework combining water fingerprinting and evolutionary analysis to trace the pollution transfer features between water sources. We collected samples in Eastern China (industrial export) and Central China (industrial acceptance) separately from two water systems. Based on the water pollutant fingerprints and evolutionary trees, we traced the pollution transfer associated with industrial transfer between the two areas. The results are consistent with four episodes of industrial transfers over the past decade. Our results also show likely types of the transferred industries - electronics, plastics, and biomedicines - that contribute to the water pollution transfer. PMID:23301152

  9. Water pollutant fingerprinting tracks recent industrial transfer from coastal to inland China: A case study

    NASA Astrophysics Data System (ADS)

    Zheng, Weiwei; Wang, Xia; Tian, Dajun; Jiang, Songhui; Andersen, Melvin E.; He, Genhsjeng; Crabbe, M. James C.; Zheng, Yuxin; Zhong, Yang; Qu, Weidong

    2013-01-01

    In recent years, China's developed regions have transferred industries to undeveloped regions. Large numbers of unlicensed or unregistered enterprises are widespread in these undeveloped regions and they are subject to minimal regulation. Current methods for tracing industrial transfers in these areas, based on enterprise registration information or economic surveys, do not work. We have developed an analytical framework combining water fingerprinting and evolutionary analysis to trace the pollution transfer features between water sources. We collected samples in Eastern China (industrial export) and Central China (industrial acceptance) separately from two water systems. Based on the water pollutant fingerprints and evolutionary trees, we traced the pollution transfer associated with industrial transfer between the two areas. The results are consistent with four episodes of industrial transfers over the past decade. Our results also show likely types of the transferred industries - electronics, plastics, and biomedicines - that contribute to the water pollution transfer.

  10. To transfer or not to transfer? Kinematics and laterality quotient predict interlimb transfer of motor learning.

    PubMed

    Lefumat, Hannah Z; Vercher, Jean-Louis; Miall, R Chris; Cole, Jonathan; Buloup, Frank; Bringoux, Lionel; Bourdin, Christophe; Sarlegna, Fabrice R

    2015-11-01

    Humans can remarkably adapt their motor behavior to novel environmental conditions, yet it remains unclear which factors enable us to transfer what we have learned with one limb to the other. Here we tested the hypothesis that interlimb transfer of sensorimotor adaptation is determined by environmental conditions but also by individual characteristics. We specifically examined the adaptation of unconstrained reaching movements to a novel Coriolis, velocity-dependent force field. Right-handed subjects sat at the center of a rotating platform and performed forward reaching movements with the upper limb toward flashed visual targets in prerotation, per-rotation (i.e., adaptation), and postrotation tests. Here only the dominant arm was used during adaptation and interlimb transfer was assessed by comparing performance of the nondominant arm before and after dominant-arm adaptation. Vision and no-vision conditions did not significantly influence interlimb transfer of trajectory adaptation, which on average was significant but limited. We uncovered a substantial heterogeneity of interlimb transfer across subjects and found that interlimb transfer can be qualitatively and quantitatively predicted for each healthy young individual. A classifier showed that in our study, interlimb transfer could be predicted based on the subject's task performance, most notably motor variability during learning, and his or her laterality quotient. Positive correlations suggested that variability of motor performance and lateralization of arm movement control facilitate interlimb transfer. We further show that these individual characteristics can predict the presence and the magnitude of interlimb transfer of left-handers. Overall, this study suggests that individual characteristics shape the way the nervous system can generalize motor learning. Copyright © 2015 the American Physiological Society.

  11. Transference, counter-transference and repetition: some implications for nursing practice.

    PubMed

    Jones, Alun C

    2005-11-01

    This discussion paper offers an introductory text for nurses and explores the psychoanalytic ideas of transference, counter-transference and repetition compulsion. Disguised case vignettes provide illustrations of the ideas as they might apply to nursing, including professional practice and occupational choice. The literature suggests that transference can be a source of creativity as well as destructiveness and influence important communications with oneself and others including the choice of nursing and other health professions as an occupation. Recognizing possibilities of transference, counter-transference along with repetitive patterns of behaviours, can help nurses of all specialities to address situations constructively by responding thoughtfully and appropriately. This discussion concludes with the suggestions that we know little about the motivational factors underlying nursing as an occupational preference; moreover, nursing does not have a culture of personal therapy. As such nurses are denied opportunities to understand the possible reasons underlying their occupational choice or gain experiential knowledge of interpersonal dynamics occurring between patients and colleagues. Transference and counter-transference are thought to have some bearing on all relationships. Forming a natural part of the way human beings relate to each other, transference and counter-transference can bring about sincere human interest, caring and concern. However, there is also potential for disagreements. Recognizing the possible origins of relational difficulties can offer opportunities for professional development to nurses along with the benefits for health service users.

  12. Anti-Neutrino Charged-Current Reactions on Scintillator with Low Momentum Transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gran, R.; et al.

    2018-06-01

    We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less

  13. Anti-Neutrino Charged-Current Reactions on Scintillator with Low Momentum Transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gran, R.; et al.

    2018-03-25

    We report on multi-nucleon effects in low momentum transfer (more » $< 0.8$ GeV/c) anti-neutrino interactions on scintillator. These data are from the 2010-11 anti-neutrino phase of the MINERvA experiment at Fermilab. The hadronic energy spectrum of this inclusive sample is well-described when a screening effect at low energy transfer and a two-nucleon knockout process are added to a relativistic Fermi gas model of quasi-elastic, $$\\Delta$$ resonance, and higher resonance processes. In this analysis, model elements introduced to describe previously published neutrino results have quantitatively similar benefits for this anti-neutrino sample. We present the results as a double-differential cross section to accelerate investigation of alternate models for anti-neutrino scattering off nuclei.« less

  14. Generalization of experimental data on heat transfer in permeable shells made of porous reticular materials

    NASA Astrophysics Data System (ADS)

    Polyakov, A. F.; Strat'ev, V. K.; Tret'yakov, A. F.; Shekhter, Yu. L.

    2010-06-01

    Heat transfer from six samples of porous reticular material to cooling gas (air) at small Reynolds numbers is experimentally studied. The specific features pertinent to heat transfer essentially affected by longitudinal heat conductivity along gas flow are analyzed. The experimental results are generalized in the form of dimensionless empirical relations.

  15. Principles of the radiosity method versus radiative transfer for canopy reflectance modeling

    NASA Technical Reports Server (NTRS)

    Gerstl, Siegfried A. W.; Borel, Christoph C.

    1992-01-01

    The radiosity method is introduced to plant canopy reflectance modeling. We review the physics principles of the radiosity method which originates in thermal radiative transfer analyses when hot and cold surfaces are considered within a given enclosure. The radiosity equation, which is an energy balance equation for discrete surfaces, is described and contrasted with the radiative transfer equation, which is a volumetric energy balance equation. Comparing the strengths and weaknesses of the radiosity method and the radiative transfer method, we conclude that both methods are complementary to each other. Results of sample calculations are given for canopy models with up to 20,000 discrete leaves.

  16. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  17. Automatic graphene transfer system for improved material quality and efficiency

    PubMed Central

    Boscá, Alberto; Pedrós, Jorge; Martínez, Javier; Palacios, Tomás; Calle, Fernando

    2016-01-01

    In most applications based on chemical vapor deposition (CVD) graphene, the transfer from the growth to the target substrate is a critical step for the final device performance. Manual procedures are time consuming and depend on handling skills, whereas existing automatic roll-to-roll methods work well for flexible substrates but tend to induce mechanical damage in rigid ones. A new system that automatically transfers CVD graphene to an arbitrary target substrate has been developed. The process is based on the all-fluidic manipulation of the graphene to avoid mechanical damage, strain and contamination, and on the combination of capillary action and electrostatic repulsion between the graphene and its container to ensure a centered sample on top of the target substrate. The improved carrier mobility and yield of the automatically transferred graphene, as compared to that manually transferred, is demonstrated by the optical and electrical characterization of field-effect transistors fabricated on both materials. In particular, 70% higher mobility values, with a 30% decrease in the unintentional doping and a 10% strain reduction are achieved. The system has been developed for lab-scale transfer and proved to be scalable for industrial applications. PMID:26860260

  18. Charge transfer in photorefractive CdTe:Ge at different wavelengths

    NASA Astrophysics Data System (ADS)

    Shcherbin, K.; Odoulov, S.; Ramaz, F.; Farid, B.; Briat, B.; von Bardeleben, H. J.; Delaye, P.; Roosen, G.

    2001-10-01

    The charge transfer processes in photorefractive CdTe:Ge were modeled using the data of optical absorption, magnetic circular dichroism (MCD) and electron paramagnetic resonance (EPR) spectroscopies. Within the developed model the variations in the photorefractive properties of different CdTe:Ge samples are explained by differences in the relative concentrations of donor and trap centers. The existence of two different centers of comparable concentrations, each in two charge states, allows charge redistribution between them and gives rise to optical sensitization of some CdTe:Ge samples for photorefractive recording under an auxiliary illumination. In the present article we follow the proposal of pseudo-3D presentation of light-induced absorption to distinguish the main charge transfer processes at different excitation energies and explain the sensitization of CdTe:Ge for photorefractive recording at 1.06, 1.32 and 1.55 μm by light with appropriate wavelength.

  19. Influence of drying air parameters on mass transfer characteristics of apple slices

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2016-10-01

    To efficiently design both new drying process and equipment and/or to improve the existing systems, accurate values of mass transfer characteristics are necessary. The present study aimed to investigate the influence of drying air parameters (i.e. temperature, velocity and relative humidity) on effective diffusivity and convective mass transfer coefficient of apple slices. The Dincer and Dost model was used to determine the mass transfer characteristics. The obtained Biot number indicated that the moisture transfer in the apple slices was controlled by both internal and external resistance. The effective diffusivity and mass transfer coefficient values obtained to be in the ranges of 7.13 × 10-11-7.66 × 10-10 and 1.46 × 10-7-3.39 × 10-7 m s-1, respectively and the both of them increased with increasing drying air temperature and velocity, and decreasing relative humidity. The validation of the model showed that the model predicted the experimental drying curves of the samples with a good accuracy.

  20. Simultaneous Heat and Mass Transfer Model for Convective Drying of Building Material

    NASA Astrophysics Data System (ADS)

    Upadhyay, Ashwani; Chandramohan, V. P.

    2018-04-01

    A mathematical model of simultaneous heat and moisture transfer is developed for convective drying of building material. A rectangular brick is considered for sample object. Finite-difference method with semi-implicit scheme is used for solving the transient governing heat and mass transfer equation. Convective boundary condition is used, as the product is exposed in hot air. The heat and mass transfer equations are coupled through diffusion coefficient which is assumed as the function of temperature of the product. Set of algebraic equations are generated through space and time discretization. The discretized algebraic equations are solved by Gauss-Siedel method via iteration. Grid and time independent studies are performed for finding the optimum number of nodal points and time steps respectively. A MATLAB computer code is developed to solve the heat and mass transfer equations simultaneously. Transient heat and mass transfer simulations are performed to find the temperature and moisture distribution inside the brick.

  1. The transfer instability index: a novel metric of emergency department transfer relationships.

    PubMed

    Kindermann, Dana R; Mutter, Ryan L; Houchens, Robert L; Barrett, Marguerite L; Pines, Jesse M

    2015-02-01

    In this study, the objective was to characterize emergency department (ED) transfer relationships and study the factors that predict the stability of those relationships. A metric is derived for ED transfer relationships that may be useful in assessing emergency care regionalization and as a resource for future emergency medicine research. Emergency department records at transferring hospitals were linked to ED and inpatient records at receiving hospitals in nine U.S. states using the 2010 Healthcare Cost and Utilization Project State Emergency Department Databases and State Inpatient Databases, the American Hospital Association Annual Survey, and the Trauma Information Exchange Program. Using the Clinical Classification Software to categorize conditions, high transfer rate conditions were placed into nine clinical groups. The authors created a new measure, the "transfer instability index," which estimates the effective number of "transfer partners" for each sending ED: this is designed to measure the stability of outgoing transfer relationships, where higher values of the index indicate less stable relationships. The index provides a measure of how many hospitals a transferring hospital sends its patients to (weighted by how often each transfer partner is used). Regression was used to analyze factors associated with higher values of the index. Sending hospitals had a median of 3.5 effective transfer partners across all conditions. The calculated transfer instability indices varied from 1 to 2.4 across disease categories. In general, higher index values were associated with treating a higher proportion of publicly insured patients: 10 and 12% increases in the Medicare and Medicaid share of ED encounters, respectively, were associated with 10 and 14% increases in the effective number of transfer partners. This public insurance effect held while studying all conditions together as well as within individual disease categories, such as cardiac, neurologic, and

  2. Art Concepts - Mars Sample (Robot)

    NASA Image and Video Library

    1987-06-09

    S87-35313 (15 May 1987)--- This artist's rendering illustrates a Mars Sample Return mission under study at Jet Propulsion Laboratory (JPL) and the NASA Johnson Space Center (JSC). As currently envisioned, the spacecraft would be launched in the mid to late 1990's into Earth-orbit by a space shuttle, released from the shuttle's cargo bay and propelled toward Mars by an upper-stage engine. A lander (left background) would separate from an orbiting vehicle (upper right) and descend to the planet's surface. The lander's payload would include a robotic rover (foreground), which would spend a year moving about the Martian terrain collecting scientifically significant rock and soil samples. The rover would then return to the lander and transfer its samples to a small rocket that would carry them into orbit and rendezvous with the orbiter for a return to Earth. As depicted here the rover consists of three two-wheeled cabs, and is fitted with a stereo camera vision system and tool-equipped arms for sample collection. The Mars Sample Return studies are funded by NASA's Office of Space Science and Applications.

  3. Acquisition of Triacylglycerol Transfer Activity by Microsomal Triglyceride Transfer Protein During Evolution

    PubMed Central

    Rava, Paul; Hussain, M. Mahmood

    2008-01-01

    Microsomal triglyceride transfer protein (MTP) is essential for the assembly of neutral lipid rich apolipoprotein B (apoB)-lipoproteins. Previously we reported that the Drosophila MTP transfers phospholipids but does not transfer triglycerides. In contrast, human MTP transfers both lipids. To explore the acquisition of triglyceride transfer activity by MTP, we evaluated amino acid sequences, protein structures, as well as the biochemical and cellular properties of various MTP orthologs obtained from species that diverged during evolution. All MTP orthologs shared similar secondary and tertiary structures, associated with protein disulfide isomerase, localized to the endoplasmic reticulum, and supported apoB secretion. While vertebrate MTPs transferred triglyceride invertebrate MTPs lacked this activity. Thus, triglyceride transfer activity was acquired during the transition from invertebrates to vertebrates. Within vertebrates, fish, amphibians, and birds displayed 27%, 40% and 100% triglyceride transfer activity compared to mammals. We conclude that MTP triglyceride transfer activity first appeared in fish and speculate that the acquisition of triglyceride transfer activity by MTP provided for a significant advantage in the evolution of larger and more complex organisms. PMID:17924655

  4. Heat transfer system

    DOEpatents

    McGuire, Joseph C.

    1982-01-01

    A heat transfer system for a nuclear reactor. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  5. Two-Year Comparison of Transfer and Native Student Academic Performance: University of Illinois at Urbana-Champaign, Fall 1986 Group.

    ERIC Educational Resources Information Center

    Heiser, Linda M.; Abbed, Nejla

    In 1989, a two-year study was completed comparing the academic progress of community college transfers, senior college transfers, and continuing juniors (natives) at the University of Illinois at Urbana-Champaign (UIUC). The study samples were comprised of 673 former community college students and 393 senior college transfers who entered UIUC in…

  6. Interhospital transfer handoff practices among US tertiary care centers: A descriptive survey.

    PubMed

    Herrigel, Dana J; Carroll, Madeline; Fanning, Christine; Steinberg, Michael B; Parikh, Amay; Usher, Michael

    2016-06-01

    Interhospital transfer is an understudied area within transitions of care. The process by which hospitals accept and transfer patients is not well described. National trends and best practices are unclear. To describe the demographics of large transfer centers, to identify common handoff practices, and to describe challenges and notable innovations involving the interhospital transfer handoff process. A convenience sample of 32 tertiary care centers in the United States was studied. Respondents were typically transfer center directors surveyed by phone. Data regarding transfer center demographics, handoff communication practices, electronic infrastructure, and data sharing were obtained. The median number of patients transferred each month per receiving institution was 700 (range, 250-2500); on average, 28% of these patients were transferred to an intensive care unit. Transfer protocols and practices varied by institution. Transfer center coordinators typically had a medical background (78%), and critical care-trained registered nurse was the most prevalent (38%). Common practices included: mandatory recorded 3-way physician-to-physician conversation (84%) and mandatory clinical status updates prior to patient arrival (81%). However, the timeline of clinical status updates was variable. Less frequent transfer practices included: electronic medical record (EMR) cross-talk availability and utilization (23%), real-time transfer center documentation accessibility in the EMR (32%), and referring center clinical documentation available prior to transport (29%). A number of innovative strategies to address challenges involving interhospital handoffs are reported. Interhospital transfer practices vary widely amongst tertiary care centers. Practices that lead to improved patient handoffs and reduced medical errors need additional prospective evaluation. Journal of Hospital Medicine 2016;11:413-417. © 2016 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.

  7. Characterizing 3D sensors using the 3D modulation transfer function

    NASA Astrophysics Data System (ADS)

    Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther

    2018-03-01

    The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.

  8. Haptic adaptation to slant: No transfer between exploration modes

    PubMed Central

    van Dam, Loes C. J.; Plaisier, Myrthe A.; Glowania, Catharina; Ernst, Marc O.

    2016-01-01

    Human touch is an inherently active sense: to estimate an object’s shape humans often move their hand across its surface. This way the object is sampled both in a serial (sampling different parts of the object across time) and parallel fashion (sampling using different parts of the hand simultaneously). Both the serial (moving a single finger) and parallel (static contact with the entire hand) exploration modes provide reliable and similar global shape information, suggesting the possibility that this information is shared early in the sensory cortex. In contrast, we here show the opposite. Using an adaptation-and-transfer paradigm, a change in haptic perception was induced by slant-adaptation using either the serial or parallel exploration mode. A unified shape-based coding would predict that this would equally affect perception using other exploration modes. However, we found that adaptation-induced perceptual changes did not transfer between exploration modes. Instead, serial and parallel exploration components adapted simultaneously, but to different kinaesthetic aspects of exploration behaviour rather than object-shape per se. These results indicate that a potential combination of information from different exploration modes can only occur at down-stream cortical processing stages, at which adaptation is no longer effective. PMID:27698392

  9. Progress in Developing Transfer Functions for Surface Scanning Eddy Current Inspections

    NASA Astrophysics Data System (ADS)

    Shearer, J.; Heebl, J.; Brausch, J.; Lindgren, E.

    2009-03-01

    As US Air Force (USAF) aircraft continue to age, additional inspections are required for structural components. The validation of new inspections typically requires a capability demonstration of the method using representative structure with representative damage. To minimize the time and cost required to prepare such samples, Electric Discharge machined (EDM) notches are commonly used to represent fatigue cracks in validation studies. However, the sensitivity to damage typically changes as a function of damage type. This requires a mathematical relationship to be developed between the responses from the two different flaw types to enable the use of EDM notched samples to validate new inspections. This paper reviews progress to develop transfer functions for surface scanning eddy current inspections of aluminum and titanium alloys found in structural aircraft components. Multiple samples with well characterized grown fatigue cracks and master gages with EDM notches, both with a range of flaw sizes, were used to collect flaw signals with USAF field inspection equipment. Analysis of this empirical data was used to develop a transfer function between the response from the EDM notches and grown fatigue cracks.

  10. Transfer Assembly Project, 2001: VCCS Transfer Rates.

    ERIC Educational Resources Information Center

    McHewitt, Earl R.; Taylor, Garry

    This document discusses the transfer rates of students who entered Virginia's community colleges in the fall of 1995, using the methodology developed by the Center for the Study of Community Colleges. Numerous tables in the document include individual college rates with breakdowns by race/ethnicity and gender. College-specific transfer rates are…

  11. Successful Cleaning and Study of Contamination of Si(001) in Ultrahigh Vacuum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gheorghe, N. G.; Lungu, G. A.; Husanu, M. A.

    2011-10-03

    This paper presents the very first surface physics experiment performed in ultrahigh vacuum (UHV) in Romania, using a new molecular beam epitaxy (MBE) installation. Cleaning of a Si(001) wafer was achieved by using a very simple technique: sequences of annealing at 900-1000 deg. C in ultrahigh vacuum: low 10{sup -8} mbar, with a base pressure of 1.5x10{sup -10} mbar. The preparation procedure is quite reproducible and allows repeated cleaning of the Si(001) after contamination in ultrahigh vacuum. The Si(001) single crystal surface is characterized by low energy electron diffraction (LEED), reflection high energy electron diffraction (RHEED), and Auger electron spectroscopymore » (AES). The latter technique is utilized in order to investigate the sample contamination by the residual gas in the UHV chamber, as determined by a residual gas analyzer (RGA). Unambiguous assignment of oxidized and unoxidized silicon is provided; also, an important feature is that the LVV Auger peak at 90-92 eV cannot be solely attributed to clean Si (i.e. Si surrounded only by Si), but also to silicon atoms bounded with carbon. Even with a sum of partial pressures of oxygen and carbon containing molecules in the range of 5x10{sup -10} mbar, the sample is contaminated very quickly, having a (1/e) lifetime of about 76 minutes.« less

  12. Heat transfer system

    DOEpatents

    Not Available

    1980-03-07

    A heat transfer system for a nuclear reactor is described. Heat transfer is accomplished within a sealed vapor chamber which is substantially evacuated prior to use. A heat transfer medium, which is liquid at the design operating temperatures, transfers heat from tubes interposed in the reactor primary loop to spaced tubes connected to a steam line for power generation purposes. Heat transfer is accomplished by a two-phase liquid-vapor-liquid process as used in heat pipes. Condensible gases are removed from the vapor chamber through a vertical extension in open communication with the chamber interior.

  13. Intermanual Transfer Effects in Below-Elbow Myoelectric Prosthesis Users.

    PubMed

    de Boer, Errit; Romkema, Sietske; Cutti, Andrea G; Brouwers, Michael A; Bongers, Raoul M; van der Sluis, Corry K

    2016-11-01

    To determine intermanual transfer effects in patients with a below-elbow amputation using a myoelectric prosthesis and to establish whether laterality affects these effects. Case-control. A standardized setting in a rehabilitation clinic. A convenience sample (N=44) of experienced myoelectric prosthesis users (n=22) and matched controls (n=22). Controls were matched on sex, age (±5y), and hand dominance. Both the experienced group and the control group performed several tasks using a prosthesis simulator attached to their nonaffected arm. Movement time, force control, Box and Block test (BBT) scores, and duration of hand opening. Movement times of myoelectric prosthesis users were shorter, and these users had significantly higher BBT scores and shorter hand opening durations than those of controls. No intermanual transfer effects on force control and no laterality effects were found. Intermanual transfer effects were present in experienced myoelectric prosthesis users with a below-elbow amputation, independent of laterality. These findings support the clinical relevance of intermanual transfer training, which may facilitate persons with an upper limb amputation to start training directly after the amputation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Working Memory Training and Transfer in Older Adults: Effects of Age, Baseline Performance, and Training Gains

    ERIC Educational Resources Information Center

    Zinke, Katharina; Zeintl, Melanie; Rose, Nathan S.; Putzmann, Julia; Pydde, Andrea; Kliegel, Matthias

    2014-01-01

    Recent studies suggest that working memory training may benefit older adults; however, findings regarding training and transfer effects are mixed. The current study aimed to investigate the effects of a process-based training intervention in a diverse sample of older adults and explored possible moderators of training and transfer effects. For…

  15. Study of energy transfer mechanism from ZnO nanocrystals to Eu(3+) ions.

    PubMed

    Mangalam, Vivek; Pita, Kantisara; Couteau, Christophe

    2016-12-01

    In this work, we investigate the efficient energy transfer occurring between ZnO nanocrystals (ZnO-nc) and europium (Eu(3+)) ions embedded in a SiO2 matrix prepared using the sol-gel technique. We show that a strong red emission was observed at 614 nm when the ZnO-nc were excited using a continuous optical excitation at 325 nm. This emission is due to the radiative (5)D0 → (7)F2 de-excitation of the Eu(3+) ions and has been conclusively shown to be due to the energy transfer from the excited ZnO-nc to the Eu(3+) ions. The photoluminescence excitation spectra are also examined in this work to confirm the energy transfer from ZnO-nc to the Eu(3+) ions. Furthermore, we study various de-excitation processes from the excited ZnO-nc and their contribution to the energy transfer to Eu(3+) ions. We also report the optimum fabrication process for maximum red emission at 614 nm from the samples where we show a strong dependence on the annealing temperature and the Eu(3+) concentration in the sample. The maximum red emission is observed with 12 mol% Eu(3+) annealed at 450 °C. This work provides a better understanding of the energy transfer mechanism from ZnO-nc to Eu(3+) ions and is important for applications in photonics, especially for light emitting devices.

  16. Robotic technology evolution and transfer

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.

    1992-01-01

    A report concerning technology transfer in the area of robotics is presented in vugraph form. The following topics are discussed: definition of technology innovation and tech-transfer; concepts relevant for understanding tech-transfer; models advanced to portray tech-transfer process; factors identified as promoting tech-transfer; factors identified as impeding tech-transfer; what important roles do individuals fulfill in tech-transfer; federal infrastructure for promoting tech-transfer; federal infrastructure for promoting tech-transfer; robotic technology evolution; robotic technology transferred; and recommendations for successful robotics tech-transfer.

  17. Experimental investigation of the hydraulic and heat-transfer properties of artificially fractured granite.

    PubMed

    Luo, Jin; Zhu, Yongqiang; Guo, Qinghai; Tan, Long; Zhuang, Yaqin; Liu, Mingliang; Zhang, Canhai; Xiang, Wei; Rohn, Joachim

    2017-01-05

    In this paper, the hydraulic and heat-transfer properties of two sets of artificially fractured granite samples are investigated. First, the morphological information is determined using 3D modelling technology. The area ratio is used to describe the roughness of the fracture surface. Second, the hydraulic properties of fractured granite are tested by exposing samples to different confining pressures and temperatures. The results show that the hydraulic properties of the fractures are affected mainly by the area ratio, with a larger area ratio producing a larger fracture aperture and higher hydraulic conductivity. Both the hydraulic apertureand the hydraulic conductivity decrease with an increase in the confining pressure. Furthermore, the fracture aperture decreases with increasing rock temperature, but the hydraulic conductivity increases owing to a reduction of the viscosity of the fluid flowing through. Finally, the heat-transfer efficiency of the samples under coupled hydro-thermal-mechanical conditions is analysed and discussed.

  18. Proton transfer pathways, energy landscape, and kinetics in creatine-water systems.

    PubMed

    Ivchenko, Olga; Whittleston, Chris S; Carr, Joanne M; Imhof, Petra; Goerke, Steffen; Bachert, Peter; Wales, David J

    2014-02-27

    We study the exchange processes of the metabolite creatine, which is present in both tumorous and normal tissues and has NH2 and NH groups that can transfer protons to water. Creatine produces chemical exchange saturation transfer (CEST) contrast in magnetic resonance imaging (MRI). The proton transfer pathway from zwitterionic creatine to water is examined using a kinetic transition network constructed from the discrete path sampling approach and an approximate quantum-chemical energy function, employing the self-consistent-charge density-functional tight-binding (SCC-DFTB) method. The resulting potential energy surface is visualized by constructing disconnectivity graphs. The energy landscape consists of two distinct regions corresponding to the zwitterionic creatine structures and deprotonated creatine. The activation energy that characterizes the proton transfer from the creatine NH2 group to water was determined from an Arrhenius fit of rate constants as a function of temperature, obtained from harmonic transition state theory. The result is in reasonable agreement with values obtained in water exchange spectroscopy (WEX) experiments.

  19. Randomized trial of harp therapy during in vitro fertilization-embryo transfer.

    PubMed

    Murphy, Erin M; Nichols, Jennifer; Somkuti, Steve G; Sobel, Michael; Braverman, Andrea; Barmat, Larry I

    2014-04-01

    This study evaluated whether harp therapy reduces levels of stress and improves clinical outcomes in patients undergoing embryo transfer. This prospective randomized trial enrolled 181 women undergoing embryo transfer, who were randomized to harp therapy during embryo transfer or standard treatment. Patients underwent standardized psychological testing and physiologic assessment of stress. The study was conducted in a reproductive medicine practice. No statistically significant differences were found in the heart and respiratory rates, nor was there a significant difference in event-based anxiety at baseline. Harp therapy had a significantly larger decrease in state anxiety from pre- to post-embryo transfer. Clinical pregnancy was 53% versus 48% for the harp therapy and standard treatment groups, respectively. Harp therapy decreases state, or event-based, anxiety, significantly lowering state scores posttransfer and having a positive effect on acute levels of stress. There was an increased pregnancy rate, but larger sample sizes are needed to evaluate whether harp therapy has an effect on clinical outcomes.

  20. DNA transfer-a never ending story. A study on scenarios involving a second person as carrier.

    PubMed

    Helmus, Janine; Bajanowski, Thomas; Poetsch, Micaela

    2016-01-01

    The transfer of DNA directly from one item to another has been shown in many studies with elaborate discussions on the nature of the DNA donor as well as material and surface of the items or surrounding features. Every DNA transfer scenario one can imagine seems to be possible. This evokes more and more intricate scenarios proposed by lawyers or attorneys searching for an explanation of the DNA of a certain person on a distinct item with impact on a crime. At court, the forensic genetic scientist has to comment on the probability of these scenarios thus calling for extensive studies on such settings. Here, the possibility of an involvement of a second person as a carrier of the donor's DNA in a variety of different scenarios including three pairs of people and two kinds of items (textiles and plastic bags) was investigated. All transfer settings were executed with and without gloves on the carrier's hands. DNA left on the items was isolated and analyzed using the Powerplex® ESX17 kit. In 21 out of 180 samples, all alleles of the donor DNA could be obtained on the second item (12%), on eight samples, the donor's DNA was dominant compared to all other alleles (38% of samples with complete donor profile). Additionally, 51 samples displayed at least more than half of the donor's alleles (28%). The complete DNA profile of the carrier was found in 47 out of 180 samples (42 partial profiles). In summary, it could be shown that a transfer of donor DNA from epithelial cells through a carrier to a second item is possible, even if the carrier does not wear gloves.

  1. Invisible Transfer: An Unexpected Finding in the Pursuit of Transfer

    ERIC Educational Resources Information Center

    Schieber, Danica L.

    2016-01-01

    Much research shows that students do not transfer learning well from one class to the next. This study was designed to investigate if students were transferring rhetorical strategies from their disciplinary courses to advanced writing courses. The findings suggest that business majors not only transferred rhetorical knowledge from their other…

  2. Chirped frequency transfer: a tool for synchronization and time transfer.

    PubMed

    Raupach, Sebastian M F; Grosche, Gesine

    2014-06-01

    We propose and demonstrate the phase-stabilized transfer of a chirped frequency as a tool for synchronization and time transfer. Technically, this is done by evaluating remote measurements of the transferred, chirped frequency. The gates of the frequency counters, here driven by a 10-MHz oscillation derived from a hydrogen maser, play a role analogous to the 1-pulse per second (PPS) signals usually employed for time transfer. In general, for time transfer, the gates consequently must be related to the external clock. Synchronizing observations based on frequency measurements, on the other hand, only requires a stable oscillator driving the frequency counters. In a proof of principle, we demonstrate the suppression of symmetrical delays, such as the geometrical path delay. We transfer an optical frequency chirped by around 240 kHz/s over a fiber link of around 149 km. We observe an accuracy and simultaneity, as well as a precision (Allan deviation, 18,000 s averaging interval) of the transferred frequency of around 2 × 10(-19). We apply chirped frequency transfer to remote measurements of the synchronization between two counters' gate intervals. Here, we find a precision of around 200 ps at an estimated overall uncertainty of around 500 ps. The measurement results agree with those obtained from reference measurements, being well within the uncertainty. In the present setup, timing offsets up to 4 min can be measured unambiguously. We indicate how this range can be extended further.

  3. Orbital Transfer Techniques for Round-Trip Mars Missions

    NASA Technical Reports Server (NTRS)

    Landau, Damon

    2013-01-01

    The human exploration of Phobos and Deimos or the retrieval of a surface sample launched to low-Mars orbit presents a highly constrained orbital transfer problem. In general, the plane of the target orbit will not be accessible from the arrival or departure interplanetary trajectories with an (energetically optimal) tangential burn at periapsis. The orbital design is further complicated by the addition of a high-energy parking orbit for the relatively massive Deep Space Vehicle to reduce propellant expenditure, while the crew transfers to and from the target orbit in a smaller Space Exploration Vehicle. The proposed strategy shifts the arrival and departure maneuvers away from periapsis so that the apsidal line of the parking orbit lies in the plane of the target orbit, permitting highly efficient plane change maneuvers at apoapsis of the elliptical parking orbit. An apsidal shift during the arrival or departure maneuver is approximately five times as efficient as maneuvering while in Mars orbit, thus significantly reducing the propellant necessary to transfer between the arrival, target, and departure orbits.

  4. Fuel transfer system

    DOEpatents

    Townsend, Harold E.; Barbanti, Giancarlo

    1994-01-01

    A nuclear fuel bundle fuel transfer system includes a transfer pool containing water at a level above a reactor core. A fuel transfer machine therein includes a carriage disposed in the transfer pool and under the water for transporting fuel bundles. The carriage is selectively movable through the water in the transfer pool and individual fuel bundles are carried vertically in the carriage. In a preferred embodiment, a first movable bridge is disposed over an upper pool containing the reactor core, and a second movable bridge is disposed over a fuel storage pool, with the transfer pool being disposed therebetween. A fuel bundle may be moved by the first bridge from the reactor core and loaded into the carriage which transports the fuel bundle to the second bridge which picks up the fuel bundle and carries it to the fuel storage pool.

  5. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    PubMed

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  6. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    DOEpatents

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  7. Number of children and upstream intergenerational financial transfers: evidence from Hong Kong.

    PubMed

    Chou, Kee-Lee

    2010-03-01

    This study examined financial transfers from adult children to elderly parents in Hong Kong and tested three hypotheses about the motives for such transfers. We address previous research, suggesting that family financial support for retirees will decline in the coming decades as a consequence of the reduction in the fertility rate; we also examine whether financial transfers are a function of the number of adult children in the family. We used multiple regression models based on data from a representative sample of parents aged 60 years and older to identify the correlates of the amount of transfers from adult children to their elderly parents. We found evidence for the hypothesis that upstream transfers to elderly parents are their way of withdrawing savings from a "support bank" in which they made contribution for their children's education earlier in life and that transfers are altruistic in nature, but our results provide only moderate support to the old age security hypothesis that perceives family as a source of capital. The number of children has a ceiling effect on transfers, which calls into question common assumptions about the extent to which the decline in fertility will pose a severe threat to the extent of familial support of older persons over the coming decades.

  8. Antecedents and Consequences of Residential Choice and School Transfer

    ERIC Educational Resources Information Center

    Falbo, Toni; Glover, Robert W.; Holcombe, W. Lee; Stokes, S. Lynne

    2005-01-01

    This article examines the antecedents and consequences of residential choice and school transfers within one of the eight largest urban school districts in Texas. This study is based on survey data from a representative sample of parents of K-12 students enrolled in this district. In addition to demographic characteristics of the family, the…

  9. Standard methods for sampling North American freshwater fishes

    USGS Publications Warehouse

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  10. Spontaneous desorption and phase transitions of self-assembled alkanethiol and alicyclic thiol monolayers chemisorbed on Au(111) in ultrahigh vacuum at room temperature.

    PubMed

    Ito, Eisuke; Kang, Hungu; Lee, Dongjin; Park, Joon B; Hara, Masahiko; Noh, Jaegeun

    2013-03-15

    Scanning tunneling microscopy (STM) and X-ray photoelectron spectroscopy (XPS) were used to examine the surface structure and adsorption conditions of hexanethiol (HT) and cyclohexanethiol (CHT) self-assembled monolayers (SAMs) on Au(111) as a function of storage period in ultrahigh vacuum (UHV) conditions of 3×10(-7) Pa at room temperature (RT). STM imaging revealed that after storage for 7 days, HT SAMs underwent phase transitions from c(4×2) phase to low coverage 4×√3 phase. This transition is due to a structural rearrangement of hexanethiolates that results from the spontaneous desorption of chemisorbed HT molecules on Au(111) surface. XPS measurements showed approximately 28% reduction in sulfur coverage, which indicates desorption of hexanethiolates from the surfaces. Contrary to HT SAMs, the structural order of CHT SAMs with (5×2√3)R35° phase completely disappeared after storage for 3 or 7 days. XPS results show desorption of more than 80% of the cyclohexanethiolates, even after storage for 3 days. We found that spontaneous desorption of CHT molecules on Au(111) in UHV at RT occurred quickly, whereas spontaneous desorption of HT molecules was much slower. Thermal desorption spectroscopy (TDS) results suggest CHT SAMs in UHV at RT can desorb more efficiently than HT SAMs due to formation of thiol desorption fragments that result from chemical reactions between surface hydrogen atoms and thiolates on Au(111) surfaces. This study clearly demonstrated that organic thiols chemisorbed on gold surfaces are desorbed spontaneously in UHV at RT and van der Waals interactions play an important role in determining the structural stability of thiolate SAMs in UHV. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. NanoBench: An Individually Addressable Nanotube Array

    DTIC Science & Technology

    2006-03-25

    17 (1999). 5 Cai, L., H. Tabata and T. Kawai, "Probing electrical properties of oriented DNA by conducting atomic force microscopy", Nanotechnology 12...the e-beam hits the other side of the NanoBench. This allows the cells to be kept alive in a biological medium while they are being tested. The key...advantage of the NanoBench is that the e-beam never hits the sample. UHV Technologies Inc. 7 NanoBench: An Individually Addressable Nanotube Array Final

  12. Impact of distal mutations on the network of coupled motions correlated to hydride transfer in dihydrofolate reductase.

    PubMed

    Wong, Kim F; Selzer, Tzvia; Benkovic, Stephen J; Hammes-Schiffer, Sharon

    2005-05-10

    A comprehensive analysis of the network of coupled motions correlated to hydride transfer in dihydrofolate reductase is presented. Hybrid quantum/classical molecular dynamics simulations are combined with a rank correlation analysis method to extract thermally averaged properties that vary along the collective reaction coordinate according to a prescribed target model. Coupled motions correlated to hydride transfer are identified throughout the enzyme. Calculations for wild-type dihydrofolate reductase and a triple mutant, along with the associated single and double mutants, indicate that each enzyme system samples a unique distribution of coupled motions correlated to hydride transfer. These coupled motions provide an explanation for the experimentally measured nonadditivity effects in the hydride transfer rates for these mutants. This analysis illustrates that mutations distal to the active site can introduce nonlocal structural perturbations and significantly impact the catalytic rate by altering the conformational motions of the entire enzyme and the probability of sampling conformations conducive to the catalyzed reaction.

  13. Early gut mycobiota and mother-offspring transfer.

    PubMed

    Schei, Kasper; Avershina, Ekaterina; Øien, Torbjørn; Rudi, Knut; Follestad, Turid; Salamati, Saideh; Ødegård, Rønnaug Astri

    2017-08-24

    The fungi in the gastrointestinal tract, the gut mycobiota, are now recognised as a significant part of the gut microbiota, and they may be important to human health. In contrast to the adult gut mycobiota, the establishment of the early gut mycobiota has never been described, and there is little knowledge about the fungal transfer from mother to offspring. In a prospective cohort, we followed 298 pairs of healthy mothers and offspring from 36 weeks of gestation until 2 years of age (1516 samples) and explored the gut mycobiota in maternal and offspring samples. Half of the pregnant mothers were randomised into drinking probiotic milk during and after pregnancy. The probiotic bacteria included Lactobacillus rhamnosus GG (LGG), Bifidobacterium animalis subsp. lactis Bb-12 and Lactobacillus acidophilus La-5. We quantified the fungal abundance of all the samples using qPCR of the fungal internal transcribed spacer (ITS)1 segment, and we sequenced the 18S rRNA gene ITS1 region of 90 high-quantity samples using the MiSeq platform (Illumina). The gut mycobiota was detected in most of the mothers and the majority of the offspring. The offspring showed increased odds of having detectable faecal fungal DNA if the mother had detectable fungal DNA as well (OR = 1.54, p = 0.04). The fungal alpha diversity in the offspring gut increased from its lowest at 10 days after birth, which was the earliest sampling point. The fungal diversity and fungal species showed a succession towards the maternal mycobiota as the child aged, with Debaryomyces hansenii being the most abundant species during breast-feeding and Saccharomyces cerevisiae as the most abundant after weaning. Probiotic consumption increased the gut mycobiota abundance in pregnant mothers (p = 0.01). This study provides the first insight into the early fungal establishment and the succession of fungal species in the gut mycobiota. The results support the idea that the fungal host phenotype is transferred from

  14. Classification of foods by transferring knowledge from ImageNet dataset

    NASA Astrophysics Data System (ADS)

    Heravi, Elnaz J.; Aghdam, Hamed H.; Puig, Domenec

    2017-03-01

    Automatic classification of foods is a way to control food intake and tackle with obesity. However, it is a challenging problem since foods are highly deformable and complex objects. Results on ImageNet dataset have revealed that Convolutional Neural Network has a great expressive power to model natural objects. Nonetheless, it is not trivial to train a ConvNet from scratch for classification of foods. This is due to the fact that ConvNets require large datasets and to our knowledge there is not a large public dataset of food for this purpose. Alternative solution is to transfer knowledge from trained ConvNets to the domain of foods. In this work, we study how transferable are state-of-art ConvNets to the task of food classification. We also propose a method for transferring knowledge from a bigger ConvNet to a smaller ConvNet by keeping its accuracy similar to the bigger ConvNet. Our experiments on UECFood256 datasets show that Googlenet, VGG and residual networks produce comparable results if we start transferring knowledge from appropriate layer. In addition, we show that our method is able to effectively transfer knowledge to the smaller ConvNet using unlabeled samples.

  15. Fuel transfer system

    DOEpatents

    Townsend, H.E.; Barbanti, G.

    1994-03-01

    A nuclear fuel bundle fuel transfer system includes a transfer pool containing water at a level above a reactor core. A fuel transfer machine therein includes a carriage disposed in the transfer pool and under the water for transporting fuel bundles. The carriage is selectively movable through the water in the transfer pool and individual fuel bundles are carried vertically in the carriage. In a preferred embodiment, a first movable bridge is disposed over an upper pool containing the reactor core, and a second movable bridge is disposed over a fuel storage pool, with the transfer pool being disposed therebetween. A fuel bundle may be moved by the first bridge from the reactor core and loaded into the carriage which transports the fuel bundle to the second bridge which picks up the fuel bundle and carries it to the fuel storage pool. 6 figures.

  16. Heat transfer probe

    DOEpatents

    Frank, Jeffrey I.; Rosengart, Axel J.; Kasza, Ken; Yu, Wenhua; Chien, Tai-Hsin; Franklin, Jeff

    2006-10-10

    Apparatuses, systems, methods, and computer code for, among other things, monitoring the health of samples such as the brain while providing local cooling or heating. A representative device is a heat transfer probe, which includes an inner channel, a tip, a concentric outer channel, a first temperature sensor, and a second temperature sensor. The inner channel is configured to transport working fluid from an inner inlet to an inner outlet. The tip is configured to receive at least a portion of the working fluid from the inner outlet. The concentric outer channel is configured to transport the working fluid from the inner outlet to an outer outlet. The first temperature sensor is coupled to the tip, and the second temperature sensor spaced apart from the first temperature sensor.

  17. An Efficient Approach for Mars Sample Return Using Emerging Commercial Capabilities

    NASA Technical Reports Server (NTRS)

    Gonzales, Andrew A.; Stoker, Carol R.

    2016-01-01

    Mars Sample Return is the highest priority science mission for the next decade as recommended by the 2011 Decadal Survey of Planetary Science. This article presents the results of a feasibility study for a Mars Sample Return mission that efficiently uses emerging commercial capabilities expected to be available in the near future. The motivation of our study was the recognition that emerging commercial capabilities might be used to perform Mars Sample Return with an Earth-direct architecture, and that this may offer a desirable simpler and lower cost approach. The objective of the study was to determine whether these capabilities can be used to optimize the number of mission systems and launches required to return the samples, with the goal of achieving the desired simplicity. All of the major element required for the Mars Sample Return mission are described. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships. The analysis shows the feasibility of a complete and closed Mars Sample Return mission design based on the following scenario: A SpaceX Falcon Heavy launch vehicle places a modified version of a SpaceX Dragon capsule, referred to as "Red Dragon", onto a Trans Mars Injection trajectory. The capsule carries all the hardware needed to return to Earth Orbit samples collected by a prior mission, such as the planned NASA Mars 2020 sample collection rover. The payload includes a fully fueled Mars Ascent Vehicle; a fueled Earth Return Vehicle, support equipment, and a mechanism to transfer samples from the sample cache system onboard the rover to the Earth Return Vehicle. The Red Dragon descends to land on the surface of Mars using Supersonic Retropropulsion. After collected samples are transferred to the Earth Return Vehicle, the single-stage Mars Ascent Vehicle launches the Earth Return Vehicle from the surface of Mars to a Mars phasing orbit. After a brief phasing period, the Earth Return

  18. An efficient approach for Mars Sample Return using emerging commercial capabilities

    NASA Astrophysics Data System (ADS)

    Gonzales, Andrew A.; Stoker, Carol R.

    2016-06-01

    Mars Sample Return is the highest priority science mission for the next decade as recommended by the 2011 Decadal Survey of Planetary Science (Squyres, 2011 [1]). This article presents the results of a feasibility study for a Mars Sample Return mission that efficiently uses emerging commercial capabilities expected to be available in the near future. The motivation of our study was the recognition that emerging commercial capabilities might be used to perform Mars Sample Return with an Earth-direct architecture, and that this may offer a desirable simpler and lower cost approach. The objective of the study was to determine whether these capabilities can be used to optimize the number of mission systems and launches required to return the samples, with the goal of achieving the desired simplicity. All of the major element required for the Mars Sample Return mission are described. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships. The analysis shows the feasibility of a complete and closed Mars Sample Return mission design based on the following scenario: A SpaceX Falcon Heavy launch vehicle places a modified version of a SpaceX Dragon capsule, referred to as ;Red Dragon;, onto a Trans Mars Injection trajectory. The capsule carries all the hardware needed to return to Earth Orbit samples collected by a prior mission, such as the planned NASA Mars 2020 sample collection rover. The payload includes a fully fueled Mars Ascent Vehicle; a fueled Earth Return Vehicle, support equipment, and a mechanism to transfer samples from the sample cache system onboard the rover to the Earth Return Vehicle. The Red Dragon descends to land on the surface of Mars using Supersonic Retropropulsion. After collected samples are transferred to the Earth Return Vehicle, the single-stage Mars Ascent Vehicle launches the Earth Return Vehicle from the surface of Mars to a Mars phasing orbit. After a brief phasing period, the

  19. An Efficient Approach for Mars Sample Return Using Emerging Commercial Capabilities.

    PubMed

    Gonzales, Andrew A; Stoker, Carol R

    2016-06-01

    Mars Sample Return is the highest priority science mission for the next decade as recommended by the 2011 Decadal Survey of Planetary Science [1]. This article presents the results of a feasibility study for a Mars Sample Return mission that efficiently uses emerging commercial capabilities expected to be available in the near future. The motivation of our study was the recognition that emerging commercial capabilities might be used to perform Mars Sample Return with an Earth-direct architecture, and that this may offer a desirable simpler and lower cost approach. The objective of the study was to determine whether these capabilities can be used to optimize the number of mission systems and launches required to return the samples, with the goal of achieving the desired simplicity. All of the major element required for the Mars Sample Return mission are described. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships. The analysis shows the feasibility of a complete and closed Mars Sample Return mission design based on the following scenario: A SpaceX Falcon Heavy launch vehicle places a modified version of a SpaceX Dragon capsule, referred to as "Red Dragon", onto a Trans Mars Injection trajectory. The capsule carries all the hardware needed to return to Earth Orbit samples collected by a prior mission, such as the planned NASA Mars 2020 sample collection rover. The payload includes a fully fueled Mars Ascent Vehicle; a fueled Earth Return Vehicle, support equipment, and a mechanism to transfer samples from the sample cache system onboard the rover to the Earth Return Vehicle. The Red Dragon descends to land on the surface of Mars using Supersonic Retropropulsion. After collected samples are transferred to the Earth Return Vehicle, the single-stage Mars Ascent Vehicle launches the Earth Return Vehicle from the surface of Mars to a Mars phasing orbit. After a brief phasing period, the Earth Return

  20. An Efficient Approach for Mars Sample Return Using Emerging Commercial Capabilities

    PubMed Central

    Gonzales, Andrew A.; Stoker, Carol R.

    2016-01-01

    Mars Sample Return is the highest priority science mission for the next decade as recommended by the 2011 Decadal Survey of Planetary Science [1]. This article presents the results of a feasibility study for a Mars Sample Return mission that efficiently uses emerging commercial capabilities expected to be available in the near future. The motivation of our study was the recognition that emerging commercial capabilities might be used to perform Mars Sample Return with an Earth-direct architecture, and that this may offer a desirable simpler and lower cost approach. The objective of the study was to determine whether these capabilities can be used to optimize the number of mission systems and launches required to return the samples, with the goal of achieving the desired simplicity. All of the major element required for the Mars Sample Return mission are described. Mission system elements were analyzed with either direct techniques or by using parametric mass estimating relationships. The analysis shows the feasibility of a complete and closed Mars Sample Return mission design based on the following scenario: A SpaceX Falcon Heavy launch vehicle places a modified version of a SpaceX Dragon capsule, referred to as “Red Dragon”, onto a Trans Mars Injection trajectory. The capsule carries all the hardware needed to return to Earth Orbit samples collected by a prior mission, such as the planned NASA Mars 2020 sample collection rover. The payload includes a fully fueled Mars Ascent Vehicle; a fueled Earth Return Vehicle, support equipment, and a mechanism to transfer samples from the sample cache system onboard the rover to the Earth Return Vehicle. The Red Dragon descends to land on the surface of Mars using Supersonic Retropropulsion. After collected samples are transferred to the Earth Return Vehicle, the single-stage Mars Ascent Vehicle launches the Earth Return Vehicle from the surface of Mars to a Mars phasing orbit. After a brief phasing period, the Earth

  1. Energy Transfer Efficiency from ZnO-Nanocrystals to Eu3+ Ions Embedded in SiO₂ Film for Emission at 614 nm.

    PubMed

    Mangalam, Vivek; Pita, Kantisara

    2017-08-10

    In this work, we study the energy transfer mechanism from ZnO nanocrystals (ZnO-nc) to Eu 3+ ions by fabricating thin-film samples of ZnO-nc and Eu 3+ ions embedded in a SiO₂ matrix using the low-cost sol-gel technique. The time-resolved photoluminescence (TRPL) measurements from the samples were analyzed to understand the contribution of energy transfer from the various ZnO-nc emission centers to Eu 3+ ions. The decay time obtained from the TRPL measurements was used to calculate the energy transfer efficiencies from the ZnO-nc emission centers, and these results were compared with the energy transfer efficiencies calculated from steady-state photoluminescence emission results. The results in this work show that high transfer efficiencies from the excitonic and Zn defect emission centers is mostly due to the energy transfer from ZnO-nc to Eu 3+ ions which results in the radiative emission from the Eu 3+ ions at 614 nm, while the energy transfer from the oxygen defect emissions is most probably due to the energy transfer from ZnO-nc to the new defects created due to the incorporation of the Eu 3+ ions.

  2. Transfer Climate and EAP Education: Students Perceptions of Challenges to Learning Transfer

    ERIC Educational Resources Information Center

    James, Mark Andrew

    2010-01-01

    This study examined the applicability of the construct transfer climate in EAP education. In an EAP setting, transfer climate can be viewed as the support for learning transfer from an EAP course that students perceive in mainstream academic courses. The research question was as follows: What can a transfer climate perspective reveal about…

  3. Transference, Counter-Transference, and Reflexivity in Intercultural Education

    ERIC Educational Resources Information Center

    Shim, Jenna Min

    2015-01-01

    The article addresses the contributions psychoanalytic theory, particularly its concepts of "transference and counter-transference," can make to our understanding of reflexivity in intercultural education (IE). After the introduction, the article is organized into three parts. The first part is a psychoanalytic discussion that focuses on…

  4. Passive West Nile virus antibody transfer from maternal Eastern Screech-Owls (Megascops asio) to progeny

    USGS Publications Warehouse

    Hahn, D.C.; Nemeth, N.M.; Edwards, E.; Bright, P.R.; Komar, N.

    2006-01-01

    Transovarial antibody transfer in owls has not been demonstrated for West Nile virus (WNV). We sampled chicks from captive adult WNV-antibody-positive Eastern Screech-Owls (Megascops asio) to evaluate the prevalence of transovarial maternal antibody transfer, as well as titers and duration of maternal antibodies. Twenty-four owlets aged 1 to 27 days old circulated detectable antibodies with neutralizing antibody titers ranging from 20 to 1600 (median 1:40). Demonstrating that WNV antibodies are passively transferred transovarially is important for accurate interpretation of serologic data from young birds.

  5. Transfer Ratios: Ranking the California Community Colleges on Transfer and Institution Size.

    ERIC Educational Resources Information Center

    Karpp, Edward R.

    A study was undertaken to rank the California Community Colleges according to a transfer ratio determined by the number of transfers compared to institution size. For each college, transfer ratios were computed by dividing the college's fall 1992 credit enrollment by the number of transfers from the college in the 1993-94 academic year. Four…

  6. IceBreaker: Mars Drill and Sample Delivery System

    NASA Astrophysics Data System (ADS)

    Mellerowicz, B. L.; Paulsen, G. L.; Zacny, K.; McKay, C.; Glass, B. J.; Dave, A.; Davila, A. F.; Marinova, M.

    2012-12-01

    We report on the development and testing of a one meter class prototype Mars drill and cuttings sample delivery system. The IceBreaker drill consists of a rotary-percussive drill head, a sampling auger with a bit at the end having an integrated temperature sensor, a Z-stage for advancing the auger into the ground, and a sam-pling station for moving the augered ice shavings or soil cuttings into a sample cup. The drill is deployed from a 3 Degree of Freedom (DOF) robotic arm. The drill demonstrated drilling in ice-cemented ground, ice, and rocks at the 1-1-100-100 level; that is the drill reached 1 meter in 1 hour with 100 Watts of power and 100 Newton Weight on Bit. This cor-responds to an average energy of 100 Whr. The drill has been extensively tested in the Mars chamber to a depth of 1 meter, as well as in the Antarctic and the Arctic Mars analog sites. We also tested three sample delivery systems: 1) 4 DOF arm with a custom soil scoop at the end; 2) Pneumatic based, and 3) Drill based enabled by the 3 (DOF) drill deployment boom. In all approaches there is an air-gap between the sterilized drill (which penetrates subsurface) and the sample transfer hardware (which is not going to be sterilized). The air gap satisfies the planetary protection requirements. The scoop acquires cuttings sample once they are augered to the surface, and drops them into an in-strument inlet port. The system has been tested in the Mars chamber and in the Arctic. The pneumatic sample delivery system uses compressed gas to move the sample captured inside a small chamber inte-grated with the auger, directly into the instrument. The system was tested in the Mars chamber. In the third approach the drill auger captures the sample on its flutes, the 3 DOF boom positions the tip of the auger above the instrument, and then the auger discharges the sample into an instrument. This approach was tested in the labolatory (at STP). The above drilling and sample delivery tests have shown that drilling

  7. Mars Sample Return mission: Two alternate scenarios

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Two scenarios for accomplishing a Mars Sample Return mission are presented herein. Mission A is a low cost, low mass scenario, while Mission B is a high technology, high science alternative. Mission A begins with the launch of one Titan IV rocket with a Centaur G' upper stage. The Centaur performs the trans-Mars injection burn and is then released. The payload consists of two lander packages and the Orbital Transfer Vehicle, which is responsible for supporting the landers during launch and interplanetary cruise. After descending to the surface, the landers deploy small, local rovers to collect samples. Mission B starts with 4 Titan IV launches, used to place the parts of the Planetary Transfer Vehicle (PTV) into orbit. The fourth launch payload is able to move to assemble the entire vehicle by simple docking routines. Once complete, the PTV begins a low thrust trajectory out from low Earth orbit, through interplanetary space, and into low Martian orbit. It deploys a communication satellite into a 1/2 sol orbit and then releases the lander package at 500 km altitude. The lander package contains the lander, the Mars Ascent Vehicle (MAV), two lighter than air rovers (called Aereons), and one conventional land rover. The entire package is contained with a biconic aeroshell. After release from the PTV, the lander package descends to the surface, where all three rovers are released to collect samples and map the terrain.

  8. Automatic transfer function generation for volume rendering of high-resolution x-ray 3D digital mammography images

    NASA Astrophysics Data System (ADS)

    Alyassin, Abdal M.

    2002-05-01

    3D Digital mammography (3DDM) is a new technology that provides high resolution X-ray breast tomographic data. Like any other tomographic medical imaging modalities, viewing a stack of tomographic images may require time especially if the images are of large matrix size. In addition, it may cause difficulty to conceptually construct 3D breast structures. Therefore, there is a need to readily visualize the data in 3D. However, one of the issues that hinder the usage of volume rendering (VR) is finding an automatic way to generate transfer functions that efficiently map the important diagnostic information in the data. We have developed a method that randomly samples the volume. Based on the mean and the standard deviation of these samples, the technique determines the lower limit and upper limit of a piecewise linear ramp transfer function. We have volume rendered several 3DDM data using this technique and compared visually the outcome with the result from a conventional automatic technique. The transfer function generated through the proposed technique provided superior VR images over the conventional technique. Furthermore, the improvement in the reproducibility of the transfer function correlated with the number of samples taken from the volume at the expense of the processing time.

  9. NASA Curation Preparation for Ryugu Sample Returned by JAXA's Hayabusa2 Mission

    NASA Technical Reports Server (NTRS)

    Nakamura-Messenger, Keiko; Righter, Kevin; Snead, Christopher J.; McCubbin, Francis M.; Pace, Lisa F.; Zeigler, Ryan A.; Evans, Cindy

    2017-01-01

    The NASA OSIRIS-REx and JAXA Hayabusa2 missions to near-Earth asteroids Bennu and Ryugu share similar mission goals of understanding the origins of primitive, organic-rich asteroids. Under an agreement between JAXA and NASA, there is an on-going and productive collaboration between science teams of Hayabusa2 and OSIRIS-REx missions. Under this agreement, a portion of each of the returned sample masses will be exchanged between the agencies and the scientific results of their study will be shared. NASA’s portion of the returned Hayabusa2 sample, consisting of 10% of the returned mass, will be jointly separated by NASA and JAXA. The sample will be legally and physically transferred to NASA’s dedicated Hayabusa2 curation facility at Johnson Space Center (JSC) no later than one year after the return of the Hayabusa2 sample to Earth (December 2020). The JSC Hayabusa2 curation cleanroom facility design has now been completed. In the same manner, JAXA will receive 0.5% of the total returned OSIRIS-REx sample (minimum required sample to return 60 g, maximum sample return capacity of 2 kg) from the rest of the specimen. No later than one year after the return of the OSIRIS-REx sample to Earth (September 2023), legal, physical, and permanent custody of this sample subset will be transferred to JAXA, and the sample subset will be brought to JAXA’s Extraterrestrial Sample Curation Center (ESCuC) at Institute of Space and Astronautical Science, Sagamihara City Japan.

  10. Experimental investigation of the hydraulic and heat-transfer properties of artificially fractured granite

    PubMed Central

    Luo, Jin; Zhu, Yongqiang; Guo, Qinghai; Tan, Long; Zhuang, Yaqin; Liu, Mingliang; Zhang, Canhai; Xiang, Wei; Rohn, Joachim

    2017-01-01

    In this paper, the hydraulic and heat-transfer properties of two sets of artificially fractured granite samples are investigated. First, the morphological information is determined using 3D modelling technology. The area ratio is used to describe the roughness of the fracture surface. Second, the hydraulic properties of fractured granite are tested by exposing samples to different confining pressures and temperatures. The results show that the hydraulic properties of the fractures are affected mainly by the area ratio, with a larger area ratio producing a larger fracture aperture and higher hydraulic conductivity. Both the hydraulic apertureand the hydraulic conductivity decrease with an increase in the confining pressure. Furthermore, the fracture aperture decreases with increasing rock temperature, but the hydraulic conductivity increases owing to a reduction of the viscosity of the fluid flowing through. Finally, the heat-transfer efficiency of the samples under coupled hydro-thermal-mechanical conditions is analysed and discussed. PMID:28054594

  11. Aspects of Student Transfer and Post-Transfer Success at Virginia Public Institutions

    ERIC Educational Resources Information Center

    State Council of Higher Education for Virginia, 2016

    2016-01-01

    This report provides a snapshot of certain aspects of transfer student success and costs using data from four transfer cohorts matriculating at four-year institutions between 2006-07 and 2009-10. These cohorts allowed for the tracking of students post-transfer for up to six years. Transfer efficiency can have a direct and significant effect on the…

  12. Transfer in Virginia--an Update. Transfer Connection, 1996.

    ERIC Educational Resources Information Center

    Virginia State Dept. of Community Colleges, Richmond.

    The "State Policy on Transfer", adopted in 1991, continues to be highly effective in helping students transfer from two-year to four-year institutions. In addition, the policy has promoted cooperation between institutions, most of which have progressed beyond questions of policy compliance to practices that facilitate equitable admission…

  13. Shear mode ER transfer function for robotic applications

    NASA Astrophysics Data System (ADS)

    Tan, K. P.; Stanway, R.; Bullough, W. A.

    2005-06-01

    Electro-rheological (ER) fluids are becoming popular in modern industrial applications. The advantage of employing ER devices is due to the ease of energizing the ER fluids at fast speeds of response. One innovation in ER applications could be in the positioning control of the robotic arm using an ER clutch. In order to actuate the manipulator, the ER output torque response is required. However, the behaviour of this ER torque response at different input conditions is not clearly understood. Therefore, in this paper, a sample study of the ER output torque is conducted. The ER output torque responses at different input parameters are studied carefully for the establishment of an appropriate ER transfer function in shear mode. This transfer function will serve as an important feature in future ER-actuated robot arm's control process.

  14. Transfer of Learning.

    ERIC Educational Resources Information Center

    1999

    This document contains four symposium papers on transfer of learning. In "Learning Transfer in a Social Service Agency: Test of an Expectancy Model of Motivation" (Reid A. Bates) structural equation modeling is used to test the validity of a valence-instrumentality-expectancy approach to motivation to transfer learning. "The…

  15. Training Objectives, Transfer, Validation and Evaluation: A Sri Lankan Study

    ERIC Educational Resources Information Center

    Wickramasinghe, Vathsala M.

    2006-01-01

    Using a stratified random sample, this paper examines the training practices of setting objectives, transfer, validation and evaluation in Sri Lanka. The paper further sets out to compare those practices across local, foreign and joint-venture companies based on the assumption that there may be significant differences across companies of different…

  16. Factors Associated with Transfer of Training in Workplace E-Learning

    ERIC Educational Resources Information Center

    Park, Ji-Hye; Wentling, Tim

    2007-01-01

    Purpose--The purpose of this study is to investigate the effect of factors associated with e-learning, particularly computer attitudes and usability, on transfer of training in workplace e-learning courses. Design/methodology/approach--This study relied on quantitative data obtained from four online survey questionnaires. The sample of this study…

  17. Colony differences in termiticide transfer studies, a role for behavior?

    Treesearch

    Thomas Shelton

    2010-01-01

    Donor-recipient termiticide transfer laboratory tests were performed by using destructive sampling with two delayed-action non-repellent (DANR) termiticides against each of three colonies of Reticulitermes flavipes (Kollar). Two of the three colonies showed no response to indoxacarb, but all three showed a response to chlorantraniliprole. These results indicate that...

  18. The research of full automatic oil filtering control technology of high voltage insulating oil

    NASA Astrophysics Data System (ADS)

    Gong, Gangjun; Zhang, Tong; Yan, Guozeng; Zhang, Han; Chen, Zhimin; Su, Chang

    2017-09-01

    In this paper, the design scheme of automatic oil filter control system for transformer oil in UHV substation is summarized. The scheme specifically includes the typical double tank filter connection control method of the transformer oil of the UHV substation, which distinguishes the single port and the double port connection structure of the oil tank. Finally, the design scheme of the temperature sensor and respirator is given in detail, and the detailed evaluation and application scenarios are given for reference.

  19. Propulsion Technology Development for Sample Return Missions Under NASA's ISPT Program

    NASA Technical Reports Server (NTRS)

    Anderson, David J.; Pencil, Eric J.; Vento, Daniel; Dankanich, John W.; Munk, Michelle M.; Hahne, David

    2011-01-01

    The In-Space Propulsion Technology (ISPT) Program was tasked in 2009 to start development of propulsion technologies that would enable future sample return missions. Sample return missions could be quite varied, from collecting and bringing back samples of comets or asteroids, to soil, rocks, or atmosphere from planets or moons. The paper will describe the ISPT Program s propulsion technology development activities relevant to future sample return missions. The sample return propulsion technology development areas for ISPT are: 1) Sample Return Propulsion (SRP), 2) Planetary Ascent Vehicles (PAV), 3) Entry Vehicle Technologies (EVT), and 4) Systems/mission analysis and tools that focuses on sample return propulsion. The Sample Return Propulsion area is subdivided into: a) Electric propulsion for sample return and low cost Discovery-class missions, b) Propulsion systems for Earth Return Vehicles (ERV) including transfer stages to the destination, and c) Low TRL advanced propulsion technologies. The SRP effort will continue work on HIVHAC thruster development in FY2011 and then transitions into developing a HIVHAC system under future Electric Propulsion for sample return (ERV and transfer stages) and low-cost missions. Previous work on the lightweight propellant-tanks will continue under advanced propulsion technologies for sample return with direct applicability to a Mars Sample Return (MSR) mission and with general applicability to all future planetary spacecraft. A major effort under the EVT area is multi-mission technologies for Earth Entry Vehicles (MMEEV), which will leverage and build upon previous work related to Earth Entry Vehicles (EEV). The major effort under the PAV area is the Mars Ascent Vehicle (MAV). The MAV is a new development area to ISPT, and builds upon and leverages the past MAV analysis and technology developments from the Mars Technology Program (MTP) and previous MSR studies.

  20. Beyond Transfer Shock: Dimensions of Transfer Students' Adjustment.

    ERIC Educational Resources Information Center

    Laanan, Frankie Santos

    This study examined the adjustment process of 727 students who transferred to the University of California, Los Angeles (UCLA) in fall 1994 or fall 1995. The Transfer Students' Questionnaire (TSQ) was organized into three main sections: social demographics, perceptions of the community college experience, and perception of the UCLA experience. The…

  1. Nurses' participation in personal knowledge transfer: the role of leader-member exchange (LMX) and structural empowerment.

    PubMed

    Davies, Alicia; Wong, Carol A; Laschinger, Heather

    2011-07-01

    The purpose of this study was to test Kanter's theory by examining relationships among structural empowerment, leader-member exchange (LMX) quality and nurses' participation in personal knowledge transfer activities. Despite the current emphasis on evidence-based practice in health care, research suggests that implementation of research findings in everyday clinical practice is unsystematic at best with mixed outcomes. This study was a secondary analysis of data collected using a non-experimental, predictive mailed survey design. A random sample of 400 registered nurses who worked in urban tertiary care hospitals in Ontario yielded a final sample of 234 for a 58.5% response rate. Hierarchical multiple linear regression analysis revealed that the combination of LMX and structural empowerment accounted for 9.1% of the variance in personal knowledge transfer but only total empowerment was a significant independent predictor of knowledge transfer (β=0.291, t=4.012, P<0.001). Consistent with Kanter's Theory, higher levels of empowerment and leader-member exchange quality resulted in increased participation in personal knowledge transfer in practice. The results reinforce the pivotal role of nurse managers in supporting empowering work environments that are conducive to transfer of knowledge in practice to provide evidence-based care. © 2011 The Authors. Journal compilation © 2011 Blackwell Publishing Ltd.

  2. The effectiveness of cooling conditions on temperature of canine EDTA whole blood samples

    PubMed Central

    Sun, Xiaocun; Flatland, Bente

    2016-01-01

    Background Preanalytic factors such as time and temperature can have significant effects on laboratory test results. For example, ammonium concentration will increase 31% in blood samples stored at room temperature for 30 min before centrifugation. To reduce preanalytic error, blood samples may be placed in precooled tubes and chilled on ice or in ice water baths; however, the effectiveness of these modalities in cooling blood samples has not been formally evaluated. The purpose of this study was to evaluate the effectiveness of various cooling modalities on reducing temperature of EDTA whole blood samples. Methods Pooled samples of canine EDTA whole blood were divided into two aliquots. Saline was added to one aliquot to produce a packed cell volume (PCV) of 40% and to the second aliquot to produce a PCV of 20% (simulated anemia). Thirty samples from each aliquot were warmed to 37.7 °C and cooled in 2 ml allotments under one of three conditions: in ice, in ice after transfer to a precooled tube, or in an ice water bath. Temperature of each sample was recorded at one minute intervals for 15 min. Results Within treatment conditions, sample PCV had no significant effect on cooling. Cooling in ice water was significantly faster than cooling in ice only or transferring the sample to a precooled tube and cooling it on ice. Mean temperature of samples cooled in ice water was significantly lower at 15 min than mean temperatures of those cooled in ice, whether or not the tube was precooled. By 4 min, samples cooled in an ice water bath had reached mean temperatures less than 4 °C (refrigeration temperature), while samples cooled in other conditions remained above 4.0 °C for at least 11 min. For samples with a PCV of 40%, precooling the tube had no significant effect on rate of cooling on ice. For samples with a PCV of 20%, transfer to a precooled tube resulted in a significantly faster rate of cooling than direct placement of the warmed tube onto ice. Discussion Canine

  3. Application and testing of a procedure to evaluate transferability of habitat suitability criteria

    USGS Publications Warehouse

    Thomas, Jeff A.; Bovee, Ken D.

    1993-01-01

    A procedure designed to test the transferability of habitat suitability criteria was evaluated in the Cache la Poudre River, Colorado. Habitat suitability criteria were developed for active adult and juvenile rainbow trout in the South Platte River, Colorado. These criteria were tested by comparing microhabitat use predicted from the criteria with observed microhabitat use by adult rainbow trout in the Cache la Poudre River. A one-sided X2 test, using counts of occupied and unoccupied cells in each suitability classification, was used to test for non-random selection for optimum habitat use over usable habitat and for suitable over unsuitable habitat. Criteria for adult rainbow trout were judged to be transferable to the Cache la Poudre River, but juvenile criteria (applied to adults) were not transferable. Random subsampling of occupied and unoccupied cells was conducted to determine the effect of sample size on the reliability of the test procedure. The incidence of type I and type II errors increased rapidly as the sample size was reduced below 55 occupied and 200 unoccupied cells. Recommended modifications to the procedure included the adoption of a systematic or randomized sampling design and direct measurement of microhabitat variables. With these modifications, the procedure is economical, simple and reliable. Use of the procedure as a quality assurance device in routine applications of the instream flow incremental methodology was encouraged.

  4. Technology transfer

    NASA Technical Reports Server (NTRS)

    Penaranda, Frank E.

    1992-01-01

    The topics are presented in viewgraph form and include the following: international comparison of R&D expenditures in 1989; NASA Technology Transfer Program; NASA Technology Utilization Program thrusts for FY 1992 and FY 1993; National Technology Transfer Network; and NTTC roles.

  5. Geometric and energetic considerations of surface fluctuations during ion transfer across the water-immiscible organic liquid interface

    NASA Astrophysics Data System (ADS)

    Karnes, John J.; Benjamin, Ilan

    2016-07-01

    Molecular dynamics simulations and umbrella sampling free energy calculations are used to examine the thermodynamics, energetics, and structural fluctuations that accompany the transfer of a small hydrophilic ion (Cl-) across the water/nitrobenzene interface. By examining several constrained interface structures, we isolate the energetic costs of interfacial deformation and co-transfer of hydration waters during the ion transfer. The process is monitored using both energy-based solvation coordinates and a geometric coordinate recently introduced by Morita and co-workers to describe surface fluctuations. Our simulations show that these coordinates provide a complimentary description of the water surface fluctuations during the transfer and are necessary for elucidating the mechanism of the ion transfer.

  6. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    PubMed

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. UCH-L1-containing exosomes mediate chemotherapeutic resistance transfer in breast cancer.

    PubMed

    Ning, Kuan; Wang, Teng; Sun, Xu; Zhang, Pengfei; Chen, Yun; Jin, Jian; Hua, Dong

    2017-06-01

    Chemotherapy resistance has become a serious challenge in the treatment of breast cancer. Previous studies showed cells can transfer proteins, including those responsible for drug resistance to adjacent cells via exosomes. The switches of drug resistance via exosomes transfer were assessed by CellTiter-Blue Viability assay, flow cytometry, and immunostaining analysis. Relative protein levels of Ubiquitin carboxyl terminal hydrolase-L1 (UCH-L1), P-glycoprotein (P-gp), extracellular-signal regulated protein kinase1/2 (ERK1/2), and phospho-extracellular-signal regulated protein kinase1/2 (p-ERK1/2) were measured by Western blot. Immunohistochemistry was performed on 93 breast cancer samples to assess the associations of UCH-L1 levels with immunofluorescence value of UCH-L1 in circulating exosomes. The Adriamycin-resistant human breast cancer cells (MCF7/ADM) secreted exosomes carrying UCH-L1 and P-gp proteins into the extracellular microenvironment then integrated into Adriamycin-sensitive human breast cancer cells (MCF7/WT) in a time-dependent manner, transferring the chemoresistance phenotype. Notably, in blood samples from patients with breast cancer, the level of exosomes carrying UCH-L1 before chemotherapy was significantly negatively correlated with prognosis. Our study demonstrated that UCH-L1-containing exosomes can transfer chemoresistance to recipient cells and these exosomes may be useful as non-invasive diagnostic biomarkers for detection of chemoresitance in breast cancer patients, achieving more effective and individualized chemotherapy. © 2017 Wiley Periodicals, Inc.

  8. A compact sub-Kelvin ultrahigh vacuum scanning tunneling microscope with high energy resolution and high stability.

    PubMed

    Zhang, L; Miyamachi, T; Tomanić, T; Dehm, R; Wulfhekel, W

    2011-10-01

    We designed a scanning tunneling microscope working at sub-Kelvin temperatures in ultrahigh vacuum (UHV) in order to study the magnetic properties on the nanoscale. An entirely homebuilt three-stage cryostat is used to cool down the microscope head. The first stage is cooled with liquid nitrogen, the second stage with liquid (4)He. The third stage uses a closed-cycle Joule-Thomson refrigerator of a cooling power of 1 mW. A base temperature of 930 mK at the microscope head was achieved using expansion of (4)He, which can be reduced to ≈400 mK when using (3)He. The cryostat has a low liquid helium consumption of only 38 ml/h and standing times of up to 280 h. The fast cooling down of the samples (3 h) guarantees high sample throughput. Test experiments with a superconducting tip show a high energy resolution of 0.3 meV when performing scanning tunneling spectroscopy. The vertical stability of the tunnel junction is well below 1 pm (peak to peak) and the electric noise floor of tunneling current is about 6fA/√Hz. Atomic resolution with a tunneling current of 1 pA and 1 mV was achieved on Au(111). The lateral drift of the microscope at stable temperature is below 20 pm/h. A superconducting spilt-coil magnet allows to apply an out-of-plane magnetic field of up to 3 T at the sample surface. The flux vortices of a Nb(110) sample were clearly resolved in a map of differential conductance at 1.1 K and a magnetic field of 0.21 T. The setup is designed for in situ preparation of tip and samples under UHV condition.

  9. Scaling ice microstructures from the laboratory to nature: cryo-EBSD on large samples.

    NASA Astrophysics Data System (ADS)

    Prior, David; Craw, Lisa; Kim, Daeyeong; Peyroux, Damian; Qi, Chao; Seidemann, Meike; Tooley, Lauren; Vaughan, Matthew; Wongpan, Pat

    2017-04-01

    Electron backscatter diffraction (EBSD) has extended significantly our ability to conduct detailed quantitative microstructural investigations of rocks, metals and ceramics. EBSD on ice was first developed in 2004. Techniques have improved significantly in the last decade and EBSD is now becoming more common in the microstructural analysis of ice. This is particularly true for laboratory-deformed ice where, in some cases, the fine grain sizes exclude the possibility of using a thin section of the ice. Having the orientations of all axes (rather than just the c-axis as in an optical method) yields important new information about ice microstructure. It is important to examine natural ice samples in the same way so that we can scale laboratory observations to nature. In the case of ice deformation, higher strain rates are used in the laboratory than those seen in nature. These are achieved by increasing stress and/or temperature and it is important to assess that the microstructures produced in the laboratory are comparable with those observed in nature. Natural ice samples are coarse grained. Glacier and ice sheet ice has a grain size from a few mm up to several cm. Sea and lake ice has grain sizes of a few cm to many metres. Thus extending EBSD analysis to larger sample sizes to include representative microstructures is needed. The chief impediments to working on large ice samples are sample exchange, limitations on stage motion and temperature control. Large ice samples cannot be transferred through a typical commercial cryo-transfer system that limits sample sizes. We transfer through a nitrogen glove box that encloses the main scanning electron microscope (SEM) door. The nitrogen atmosphere prevents the cold stage and the sample from becoming covered in frost. Having a long optimal working distance for EBSD (around 30mm for the Otago cryo-EBSD facility) , by moving the camera away from the pole piece, enables the stage to move without crashing into either the

  10. Inter-Facility Transfer of Pediatric Burn Patients from U.S. Emergency Departments

    PubMed Central

    Johnson, Sarah A.; Shi, Junxin; Groner, Jonathan I.; Thakkar, Rajan K.; Fabia, Renata; Besner, Gail E.; Xiang, Huiyun; Wheeler, Krista K.

    2016-01-01

    Purpose To describe the epidemiology of pediatric burn patients seen in U.S. emergency departments (EDs) and to determine factors associated with inter-facility transfer. Methods We analyzed data from the 2012 Nationwide Emergency Department Sample. Current American Burn Association (ABA) Guidelines were used to identify children <18 who met criteria for referral to burn centers. Burn patient admission volume was used as a proxy for burn expertise. Logistic models were fitted to examine the odds of transfer from low volume hospitals. Results In 2012, there were an estimated 126,742 (95% CI: 116,104–137,380) pediatric burn ED visits in the U.S. Of the 69,003 (54.4%) meeting referral criteria, 83.2% were in low volume hospitals. Only 8.2% of patients meeting criteria were transferred from low volume hospitals. Of the 52,604 (95% CI: 48,433 – 56,775) not transferred, 98.3% were treated and released and 1.7% were admitted without transfer; 54.7% of burns involved hands. Conclusions Over 90% of pediatric burn ED patients meet ABA burn referral criteria but are not transferred from low volume hospitals. Perhaps a portion of the 92% of patients currently receiving definitive care in low volume hospitals are under-referred and would have improved clinical outcomes if transferred at the time of presentation. PMID:27554628

  11. 37 CFR 11.29 - Reciprocal transfer or initial transfer to disability inactive status.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Reciprocal transfer or initial transfer to disability inactive status. 11.29 Section 11.29 Patents, Trademarks, and Copyrights..., Sanctions, Investigations, and Proceedings § 11.29 Reciprocal transfer or initial transfer to disability...

  12. 37 CFR 11.29 - Reciprocal transfer or initial transfer to disability inactive status.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2014-07-01 2014-07-01 false Reciprocal transfer or initial transfer to disability inactive status. 11.29 Section 11.29 Patents, Trademarks, and Copyrights..., Sanctions, Investigations, and Proceedings § 11.29 Reciprocal transfer or initial transfer to disability...

  13. 37 CFR 11.29 - Reciprocal transfer or initial transfer to disability inactive status.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Reciprocal transfer or initial transfer to disability inactive status. 11.29 Section 11.29 Patents, Trademarks, and Copyrights..., Sanctions, Investigations, and Proceedings § 11.29 Reciprocal transfer or initial transfer to disability...

  14. 37 CFR 11.29 - Reciprocal transfer or initial transfer to disability inactive status.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Reciprocal transfer or initial transfer to disability inactive status. 11.29 Section 11.29 Patents, Trademarks, and Copyrights..., Sanctions, Investigations, and Proceedings § 11.29 Reciprocal transfer or initial transfer to disability...

  15. Factors Affecting Training Transfer: Participants' Motivation to Transfer Training, Literature Review

    ERIC Educational Resources Information Center

    Alawneh, Muhammad K.

    2008-01-01

    This article investigates factors that motivate participants in learning and training activities to transfer skills, knowledge and attitude from the learning setting to the workplace. Based on training transfer theories hypothesized by Holton (1996), one of the major theories that affect an organization's learning is motivation to transfer theory.…

  16. Alumina-supported sub-nanometer Pt 10 clusters: Amorphization and role of the support material in a highly active CO oxidation catalyst

    DOE PAGES

    Yin, Chunrong; Negreiros, Fabio R.; Barcaro, Giovanni; ...

    2017-02-03

    Catalytic CO oxidation is unveiled on size-selected Pt 10 clusters deposited on two very different ultrathin (≈0.5–0.7 nm thick) alumina films: (i) a highly ordered alumina obtained under ultra-high vacuum (UHV) by oxidation of the NiAl(110) surface and (ii) amorphous alumina obtained by atomic layer deposition (ALD) on a silicon chip that is a close model of real-world supports. Notably, when exposed to realistic reaction conditions, the Pt 10/UHV-alumina system undergoes a morphological transition in both the clusters and the substrate, and becomes closely akin to Pt 10/ALD-alumina, thus reconciling UHV-type surface-science and real-world experiments. The Pt 10 clusters, thoroughlymore » characterized via combined experimental techniques and theoretical analysis, exhibit among the highest CO oxidation activity per Pt atom reported for CO oxidation catalysts, due to the interplay of ultra-small size and support effects. Lastly, a coherent interdisciplinary picture then emerges for this catalytic system.« less

  17. Incomplete Multisource Transfer Learning.

    PubMed

    Ding, Zhengming; Shao, Ming; Fu, Yun

    2018-02-01

    Transfer learning is generally exploited to adapt well-established source knowledge for learning tasks in weakly labeled or unlabeled target domain. Nowadays, it is common to see multiple sources available for knowledge transfer, each of which, however, may not include complete classes information of the target domain. Naively merging multiple sources together would lead to inferior results due to the large divergence among multiple sources. In this paper, we attempt to utilize incomplete multiple sources for effective knowledge transfer to facilitate the learning task in target domain. To this end, we propose an incomplete multisource transfer learning through two directional knowledge transfer, i.e., cross-domain transfer from each source to target, and cross-source transfer. In particular, in cross-domain direction, we deploy latent low-rank transfer learning guided by iterative structure learning to transfer knowledge from each single source to target domain. This practice reinforces to compensate for any missing data in each source by the complete target data. While in cross-source direction, unsupervised manifold regularizer and effective multisource alignment are explored to jointly compensate for missing data from one portion of source to another. In this way, both marginal and conditional distribution discrepancy in two directions would be mitigated. Experimental results on standard cross-domain benchmarks and synthetic data sets demonstrate the effectiveness of our proposed model in knowledge transfer from incomplete multiple sources.

  18. A Derived Transfer of Mood Functions through Equivalence Relations

    ERIC Educational Resources Information Center

    Barnes-Holmes, Yvonne; Barnes-Holmes, Dermot; Smeets, Paul M.; Luciano, Carmen

    2004-01-01

    The present study investigated the transfer of induced happy and sad mood functions through equivalence relations. Sixteen subjects participated in a combined equivalence and mood induction procedure. In Phase 1, all subjects were trained in 2 conditional discriminations using a matching-to-sample format (i.e., A1-B1, A2-B2, A1-C1, A2-C2). In…

  19. Single-embryo transfer versus multiple-embryo transfer.

    PubMed

    Gerris, Jan

    2009-01-01

    Despite the progress made in assisted reproductive technology, live birth rates remain disappointingly low. Multiple-embryo transfer has been an accepted practice with which to increase the success rate. This has led to a higher incidence of multiple-order births compared with natural conception, which not only increase the risk of mortality and morbidity to both mother and children but are also associated with social and economic consequences. Elective single-embryo transfer (eSET) was developed in an effort to increase singleton pregnancies in assisted reproduction. Studies comparing eSET with multiple-embryo transfer highlight the benefit of this approach and suggest that, with careful patient selection and the transfer of good-quality embryos, the risk of a multiple-order pregnancy can be reduced without significantly decreasing live birth rates. Although the use of eSET has gradually increased in clinical practice, its acceptance has been limited by factors such as availability of funding and awareness of the procedure. An open discussion of eSET is warranted in an effort to enable a broader understanding by physicians and patients of the merits of this approach. Ultimately, eSET may provide a more cost-effective, potentially safer approach to patients undergoing assisted reproduction technology.

  20. How Do Transfers Survive after "Transfer Shock"? A Longitudinal Study of Transfer Student Departure at a Four-Year Institution

    ERIC Educational Resources Information Center

    Ishitani, Terry T.

    2008-01-01

    Prompted by the notion of "Transfer Shock", numerous studies examined academic performance of transfer students at senior institutions. However, few studies are found that examine how the varying nature of semester GPAs impact subsequent persistence behavior of transfer students after the initial drop in their college GPAs. Using an institutional…

  1. The Transfer Indicator.

    ERIC Educational Resources Information Center

    Cohen, Arthur M.

    1991-01-01

    Inconsistencies in the definition of transfer from two-year to four-year institutions and in the calculation of the transfer rate have given rise to incongruous findings. For example, one researcher in 1989 reported a transfer rate of less than 12% for the colleges in Illinois at the same time that the Chancellor's Office of the California…

  2. A novel methodology to characterize interfacility transfer strategies in a trauma transfer network.

    PubMed

    Gomez, David; Haas, Barbara; Larsen, Kristian; Alali, Aziz S; MacDonald, Russell D; Singh, Jeffrey M; Tien, Homer; Iwashyna, Theodore J; Rubenfeld, Gordon; Nathens, Avery B

    2016-10-01

    More than half of severely injured patients are initially transported from the scene of injury to nontrauma centers (NTCs), with many requiring subsequent transfer to trauma center (TC) care. Definitive care in the setting of severe injury is time sensitive. However, transferring severely injured patients from an NTC is a complex process often fraught with delays. Selection of the receiving TC and the mode of interfacility transport both strongly influence total transfer time and are highly amenable to quality improvement initiatives. We analyzed transfer strategies, defined as the pairing of a destination and mode of transport (land vs. rotary wing vs. fixed wing), for severely injured adult patients. Existing transfer strategies at each NTC were derived from trauma registry data. Geographic Information Systems network analysis was used to identify the strategy that minimized transfer times the most as well as alternate strategies (+15 or +30 minutes) for each NTC. Transfer network efficiency was characterized based on optimality and stability. We identified 7,702 severely injured adult patients transferred from 146 NTCs to 9 TCs. Nontrauma centers transferred severely injured patients to a median of 3 (interquartile range, 1-4) different TCs and utilized a median of 4 (interquartile range, 2-6) different transfer strategies. After allowing for the use of alternate transfer strategies, 73.1% of severely injured patients were transported using optimal/alternate strategies, and only 40.4% of NTCs transferred more than 90% of patients using an optimal/alternate transfer strategy. Three quarters (75.5%) of transfers occurred between NTCs and their most common receiving TC. More than a quarter of patients with severe traumatic injuries undergoing interfacility transport to a TC in Ontario are consistently transported using a nonoptimal combination of destination and mode of transport. Our novel analytic approach can be easily adapted to different system configurations

  3. Effect of air confinement on thermal contact resistance in nanoscale heat transfer

    NASA Astrophysics Data System (ADS)

    Pratap, Dheeraj; Islam, Rakibul; Al-Alam, Patricia; Randrianalisoa, Jaona; Trannoy, Nathalie

    2018-03-01

    Here, we report a detailed analysis of thermal contact resistance (R c) of nano-size contact formed between a Wollaston wire thermal probe and the used samples (fused silica and titanium) as a function of air pressure (from 1 Pa to 105 Pa). Moreover, we suggest an analytical model using experimental data to extract R c. We found that for both samples, the thermal contact resistance decreases with increasing air pressure. We also showed that R c strongly depends on the thermal conductivity of materials keeping other parameters the same, such as roughness of the probe and samples, as well as the contact force. We provide a physical explanation of the R c trend with pressure and thermal conductivity of the materials: R c is ascribed to the heat transfer through solid-solid (probe-sample) contact and confined air at nanoscale cavities, due to the rough nature of the materials in contact. The contribution of confined air on heat transfer through the probe sample contact is significant at atmospheric pressure but decreases as the pressure decreases. In vacuum, only the solid-solid contact contributes to R c. In addition, theoretical calculations using the well-known acoustic and diffuse mismatch models showed a high thermal conductivity material that exhibits high heat transmission and consequently low R c, supporting our findings.

  4. Mass Transfer Testing of a 12.5-cm Rotor Centrifugal Contactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. H. Meikrantz; T. G. Garn; J. D. Law

    2008-09-01

    TRUEX mass transfer tests were performed using a single stage commercially available 12.5 cm centrifugal contactor and stable cerium (Ce) and europium (Eu). Test conditions included throughputs ranging from 2.5 to 15 Lpm and rotor speeds of 1750 and 2250 rpm. Ce and Eu extraction forward distribution coefficients ranged from 13 to 19. The first and second stage strip back distributions were 0.5 to 1.4 and .002 to .004, respectively, throughout the dynamic test conditions studied. Visual carryover of aqueous entrainment in all organic phase samples was estimated at < 0.1 % and organic carryover into all aqueous phase samplesmore » was about ten times less. Mass transfer efficiencies of = 98 % for both Ce and Eu in the extraction section were obtained over the entire range of test conditions. The first strip stage mass transfer efficiencies ranged from 75 to 93% trending higher with increasing throughput. Second stage mass transfer was greater than 99% in all cases. Increasing the rotor speed from 1750 to 2250 rpm had no significant effect on efficiency for all throughputs tested.« less

  5. Soil-to-crop transfer factors of tellurium.

    PubMed

    Yang, Guosheng; Zheng, Jian; Tagami, Keiko; Uchida, Shigeo

    2014-09-01

    Stable tellurium (Te) concentrations in 148 sets of agricultural soil and associated crop samples were measured in this study to obtain soil-to-crop transfer factor (TF) of Te. We used a recently developed simple method that applies digestion of samples with aqua regia and sector field inductively coupled plasma mass spectrometry to measure low Te levels in these samples. Geometric mean (GM) concentrations of Te in soil and crops were 75μgkg(-1)-dry (range: 15-850μgkg(-1)-dry) and 1.8μgkg(-1)-dry (range: 0.1-120μgkg(-1)-dry), respectively; the Te concentration range was significantly wider in crops than in soil. Using these data, we calculated TFs and obtained their range from 1.3×10(-3) to 1.1×10(-1). The GM of TF for upland field crops was calculated to be 2.0×10(-2) and for brown rice was 3.1×10(-2); all crop types had the similar GMs of their TF values. Data comparison for TF of Te was carried out with six elements, which are present in anionic forms in soil environment like Te is, i.e. P, Br, As, Se, Mo, and I. TFs of Te and I showed the highest correlation factor for upland field crops by t-test (r=0.577, p<0.001), but no correlation was found for brown rice. We considered it likely that different water management practices in upland fields and paddy fields affected the Te transfer from soil to crops. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Transfer of inner cell mass cells derived from bovine nuclear transfer embryos into the trophoblast of bovine in vitro-produced embryos.

    PubMed

    Murakami, M; Ferguson, C E; Perez, O; Boediono, A; Paccamonti, D; Bondioli, K R; Godke, R A

    2006-01-01

    Presence of placental tissues from more normal noncloned embryos could reduce the pregnancy failure of somatic cloning in cattle. In this study, inner cell mass (ICM) cells of in vitro-produced (IVP) embryos was replaced with those of nuclear transfer (NT) embryos to reconstruct bovine blastocysts with ICM and trophoblast cells from NT and IVP embryos, respectively. A total of 65 of these reconstructed embryos were nonsurgically transferred to 20 recipient beef females. Of those, two females were diagnosed pregnant by ultrasonography on day 30 of gestation. One pregnancy was lost at 60-90 days of gestation, and the other recipient cow remained pregnant at day 240 of gestation; however, this female died on day 252 of gestation. Gross pathology of the internal organs of the recipient female, a large fetus, and a large placental tissue mass suggested the massive size of the fetus and placental tissue were likely involved in terminating the life of the recipient female. Biopsy samples were harvested from the skin of the dead recipient cow, the fetus and from cotyledonary tissue. Microsatellite DNA analysis of these samples revealed that the genotype of the fetus was the same as that of the NT donor cells and different from that of the recipient cow. Correspondingly, neither the fetus nor recipient cow had the same genotype with that of the fetal cotyledonary tissue. These results present the first known documented case of a bovine somatic NT pregnancy with nonclone placental tissues after transfer of a blastocyst reconstructed by a microsurgical method to exchange of ICM cells and trophoblast tissue between NT and IVP blastocysts.

  7. Interlimb transfer of motor skill learning during walking: No evidence for asymmetric transfer.

    PubMed

    Krishnan, Chandramouli; Ranganathan, Rajiv; Tetarbe, Manik

    2017-07-01

    Several studies have shown that learning a motor skill in one limb can transfer to the opposite limb-a phenomenon called as interlimb transfer. The transfer of motor skills between limbs, however, has shown to be asymmetric, where one side benefits to a greater extent than the other. While this phenomenon has been well-documented in the upper-extremity, evidence for interlimb transfer in the lower-extremity is limited and mixed. This study investigated the extent of interlimb transfer during walking, and tested whether this transfer was asymmetric using a foot trajectory-tracking paradigm that has been specifically used for gait rehabilitation. The paradigm involved learning a new gait pattern which required greater hip and knee flexion during the swing phase of the gait while walking on a treadmill. Twenty young adults were randomized into two equal groups, where one group (right-to-left: RL) practiced the task initially with the dominant right leg and the other group (left-to-right: LR) practiced the task initially with their non-dominant left leg. After training, both groups practiced the task with their opposite leg to test the transfer effects. The changes in tracking error on each leg were computed to quantify learning and transfer effects. The results indicated that practice with one leg improved the motor performance of the other leg; however, the amount of transfer was similar across groups, indicating that there was no asymmetry in transfer. This finding is contradictory to most upper-extremity studies (where asymmetric transfer has been reported) and points out that both differences in neural processes and types of tasks may mediate interlimb transfer. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Bessel beam CARS of axially structured samples

    NASA Astrophysics Data System (ADS)

    Heuke, Sandro; Zheng, Juanjuan; Akimov, Denis; Heintzmann, Rainer; Schmitt, Michael; Popp, Jürgen

    2015-06-01

    We report about a Bessel beam CARS approach for axial profiling of multi-layer structures. This study presents an experimental implementation for the generation of CARS by Bessel beam excitation using only passive optical elements. Furthermore, an analytical expression is provided describing the generated anti-Stokes field by a homogeneous sample. Based on the concept of coherent transfer functions, the underling resolving power of axially structured geometries is investigated. It is found that through the non-linearity of the CARS process in combination with the folded illumination geometry continuous phase-matching is achieved starting from homogeneous samples up to spatial sample frequencies at twice of the pumping electric field wave. The experimental and analytical findings are modeled by the implementation of the Debye Integral and scalar Green function approach. Finally, the goal of reconstructing an axially layered sample is demonstrated on the basis of the numerically simulated modulus and phase of the anti-Stokes far-field radiation pattern.

  9. Bessel beam CARS of axially structured samples.

    PubMed

    Heuke, Sandro; Zheng, Juanjuan; Akimov, Denis; Heintzmann, Rainer; Schmitt, Michael; Popp, Jürgen

    2015-06-05

    We report about a Bessel beam CARS approach for axial profiling of multi-layer structures. This study presents an experimental implementation for the generation of CARS by Bessel beam excitation using only passive optical elements. Furthermore, an analytical expression is provided describing the generated anti-Stokes field by a homogeneous sample. Based on the concept of coherent transfer functions, the underling resolving power of axially structured geometries is investigated. It is found that through the non-linearity of the CARS process in combination with the folded illumination geometry continuous phase-matching is achieved starting from homogeneous samples up to spatial sample frequencies at twice of the pumping electric field wave. The experimental and analytical findings are modeled by the implementation of the Debye Integral and scalar Green function approach. Finally, the goal of reconstructing an axially layered sample is demonstrated on the basis of the numerically simulated modulus and phase of the anti-Stokes far-field radiation pattern.

  10. Transfer Technique Is Associated With Shoulder Pain and Pathology in People With Spinal Cord Injury: A Cross-Sectional Investigation.

    PubMed

    Hogaboom, Nathan S; Worobey, Lynn A; Boninger, Michael L

    2016-10-01

    To evaluate how transfer technique and subject characteristics relate to ultrasound measures of shoulder soft tissue pathology and self-reported shoulder pain during transfers in a sample of wheelchair users with spinal cord injury (SCI). Cross-sectional observational study. Research laboratory, national and local veterans' wheelchair sporting events. A convenience sample of wheelchair users (N=76) with nonprogressive SCI. Participants were aged >18 years, >1 year postinjury, and could complete repeated independent wheelchair transfers without the use of their leg muscles. Not applicable. Transfer pain items from the Wheelchair User's Shoulder Pain Index; transfer technique assessed using the Transfer Assessment Instrument (TAI); and shoulder pathology markers examined using the Ultrasound Shoulder Pathology Rating Scale (USPRS). Better transfer technique (higher TAI) correlated with less injury (lower USPRS) (partial η(2)=.062, P<.05) and less pain during transfers (partial η(2)=.049, P<.10). Greater age was the strongest predictor of greater pathology (USPRS total: partial η(2)=.225, supraspinatus grade: partial η(2)=.174, P<.01). An interaction between technique and weight was found (P<.10): participants with lower body weights showed a decrease in pathology markers with better transfer technique (low weight: R(2)=.422, P<.05; middle weight: R(2)=.200, P<.01), while those with higher weight showed little change with technique (R(2)=.018, P>.05). Participants with better transfer technique exhibited less shoulder pathology and reported less pain during transfers. The relationship between technique and pathology was strongest in lower-weight participants. While causation cannot be proven because of study design, it is possible that using a better transfer technique and optimizing body weight could reduce the incidence of shoulder pathology and pain. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Understanding the Racial Transfer Gap: Modeling Underrepresented Minority and Nonminority Students' Pathways from Two-to Four-Year Institutions

    ERIC Educational Resources Information Center

    Crisp, Gloria; Nuñez, Anne-Marie

    2014-01-01

    This study models student-and institutional-level factors that influence vertical transfer among a national sample of White and underrepresented minority (URM) community college students. Results indicate that the predictors of transfer are different in many ways for White and URM students. Most notably, findings suggest that enrolling in…

  12. Applying Transfer in Practice

    ERIC Educational Resources Information Center

    Kaminski, Karen; Foley, Jeffrey M.; Kaiser, Leann M. R.

    2013-01-01

    Throughout the chapters in this issue, the authors have cited various definitions for learning transfer. For educators, in its simplest form, transfer of learning occurs when students put to practical use the knowledge and skills they gained in the classroom (near transfer). Chapter 1 defines near transfer and then goes into detail on the levels…

  13. Numerical Analysis of Heat Transfer During Quenching Process

    NASA Astrophysics Data System (ADS)

    Madireddi, Sowjanya; Krishnan, Krishnan Nambudiripad; Reddy, Ammana Satyanarayana

    2018-04-01

    A numerical model is developed to simulate the immersion quenching process of metals. The time of quench plays an important role if the process involves a defined step quenching schedule to obtain the desired characteristics. Lumped heat capacity analysis used for this purpose requires the value of heat transfer coefficient, whose evaluation requires large experimental data. Experimentation on a sample work piece may not represent the actual component which may vary in dimension. A Fluid-Structure interaction technique with a coupled interface between the solid (metal) and liquid (quenchant) is used for the simulations. Initial times of quenching shows boiling heat transfer phenomenon with high values of heat transfer coefficients (5000-2.5 × 105 W/m2K). Shape of the work piece with equal dimension shows less influence on the cooling rate Non-uniformity in hardness at the sharp corners can be reduced by rounding off the edges. For a square piece of 20 mm thickness, with 3 mm fillet radius, this difference is reduced by 73 %. The model can be used for any metal-quenchant combination to obtain time-temperature data without the necessity of experimentation.

  14. Understanding cross sample talk as a result of triboelectric charging on future mars missions

    NASA Astrophysics Data System (ADS)

    Beegle, L. W.; Anderson, R. C.; Fleming, G.

    2009-12-01

    Proper scientific analysis requires the material that is collected and analyzed by in-situ instruments be as close as possible (chemically and mineralogically) to the initial, unaltered surface material prior to its collection and delivery. However this is not always possible for automated robotic in situ analysis. Therefore it is vital to understanding how the sample has been changed/altered prior to analysis so that analysis can be put in the proper context. We have examined the transport of fines when transferred under ambient martian conditions in hardware analogous to that being developed for the Mars Science Laboratory (MSL) sample acquisition flight hardware. We will discuss the amount of cross sample contamination when different mineralogy’s are transferred under Martian environmental conditions. Similar issues have been identified as problems within the terrestrial mining, textile, and pharmaceutical research communities that may alter/change the chemical and mineralogical compositions of samples before they are delivered to the MSL Chemistry and Mineralogy (CheMin) and the Sample Analysis at Mars (SAM) analytical instruments. These cross-sample contamination will affect the overall quality of the science results and each of these processes need to be examined and understood prior to MSL landing on the surface of Mars. There are two forms of triboelectric charging that have been observed to occur on Earth and they are 1) when dissimilar material comes in contact (one material charges positive and the other negative depending on their relative positions on the triboelectric series and the work function of the material) and 2) when two similar materials come in contact, the larger particles can transfer one of their high energy electrons to a smaller particle. During the collisions, the transferred electron tends to lose energy and the charge tends not to move from the smaller particle back to the larger particle in further collisions. This transfer effect

  15. Factors predicting training transfer in health professionals participating in quality improvement educational interventions.

    PubMed

    Eid, Ahmed; Quinn, Doris

    2017-01-31

    Predictors of quality improvement (QI) training transfer are needed. This study aimed to identify these predictors among health professionals who participated in a QI training program held at a large hospital in the United States between 2005 and 2014. It also aimed to determine how these predictive factors facilitated or impeded QI training transfer. Following the Success Case Method, we used a screening survey to identify trainees with high and low levels of training transfer. We then conducted semistructured interviews with a sample of the survey respondents to document how training transfer was achieved and how lack of training transfer could be explained. The survey's response rate was 43%, with a Cronbach alpha of 0.89. We then conducted a thematic analysis of the interview transcripts of 16 physicians. The analysis revealed 3 categories of factors influencing the transfer of QI training: trainee characteristics, training course, and work environment. Relevant trainee characteristics included attitude toward change, motivation, mental processing skills, interpersonal skills, and the personality characteristics curiosity, humility, conscientiousness, resilience, wisdom, and positivity. The training project, team-based learning, and lectures were identified as relevant aspects of the training course. Work culture, work relationships, and resources were subthemes of the work environment category. We identified several QI training transfer predictors in our cohort of physicians. We hypothesize that some of these predictors may be more relevant to QI training transfer. Our results will help organizational leaders select trainees who are most likely to transfer QI training and to ensure that their work environments are conducive to QI training transfer.

  16. Acoustic Streaming and Heat and Mass Transfer Enhancement

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Gopinath, A.

    1996-01-01

    A second order effect associated with high intensity sound field, acoustic streaming has been historically investigated to gain a fundamental understanding of its controlling mechanisms and to apply it to practical aspects of heat and mass transfer enhancement. The objectives of this new research project are to utilize a unique experimental technique implementing ultrasonic standing waves in closed cavities to study the details of the generation of the steady-state convective streaming flows and of their interaction with the boundary of ultrasonically levitated near-spherical solid objects. The goals are to further extend the existing theoretical studies of streaming flows and sample interactions to higher streaming Reynolds number values, for larger sample size relative to the wavelength, and for a Prandtl and Nusselt numbers parameter range characteristic of both gaseous and liquid host media. Experimental studies will be conducted in support to the theoretical developments, and the crucial impact of microgravity will be to allow the neglect of natural thermal buoyancy. The direct application to heat and mass transfer in the absence of gravity will be emphasized in order to investigate a space-based experiment, but both existing and novel ground-based scientific and technological relevance will also be pursued.

  17. Atomic-scale defects and electronic properties of a transferred synthesized MoS2 monolayer

    NASA Astrophysics Data System (ADS)

    Delač Marion, Ida; Čapeta, Davor; Pielić, Borna; Faraguna, Fabio; Gallardo, Aurelio; Pou, Pablo; Biel, Blanca; Vujičić, Nataša; Kralj, Marko

    2018-07-01

    MoS2 monolayer samples were synthesized on a SiO2/Si wafer and transferred to Ir(111) for nano-scale characterization. The samples were extensively characterized during every step of the transfer process, and MoS2 on the final substrate was examined down to the atomic level by scanning tunneling microscopy (STM). The procedures conducted yielded high-quality monolayer MoS2 of milimeter-scale size with an average defect density of 2 × 1013 cm–2. The lift-off from the growth substrate was followed by a release of the tensile strain, visible in a widening of the optical band gap measured by photoluminescence. Subsequent transfer to the Ir(111) surface led to a strong drop of this optical signal but without further shifts of characteristic peaks. The electronic band gap was measured by scanning tunneling spectroscopy (STS), revealing n-doping and lateral nano-scale variations. The combined use of STM imaging and density functional theory (DFT) calculations allows us to identify the most recurring point-like defects as S vacancies.

  18. Atomic-scale defects and electronic properties of a transferred synthesized MoS2 monolayer.

    PubMed

    Delač Marion, Ida; Čapeta, Davor; Pielić, Borna; Faraguna, Fabio; Gallardo, Aurelio; Pou, Pablo; Biel, Blanca; Vujičić, Nataša; Kralj, Marko

    2018-07-27

    MoS 2 monolayer samples were synthesized on a SiO 2 /Si wafer and transferred to Ir(111) for nano-scale characterization. The samples were extensively characterized during every step of the transfer process, and MoS 2 on the final substrate was examined down to the atomic level by scanning tunneling microscopy (STM). The procedures conducted yielded high-quality monolayer MoS 2 of milimeter-scale size with an average defect density of 2 × 10 13 cm -2 . The lift-off from the growth substrate was followed by a release of the tensile strain, visible in a widening of the optical band gap measured by photoluminescence. Subsequent transfer to the Ir(111) surface led to a strong drop of this optical signal but without further shifts of characteristic peaks. The electronic band gap was measured by scanning tunneling spectroscopy (STS), revealing n-doping and lateral nano-scale variations. The combined use of STM imaging and density functional theory (DFT) calculations allows us to identify the most recurring point-like defects as S vacancies.

  19. Mars Sample Handling and Requirements Panel (MSHARP)

    NASA Technical Reports Server (NTRS)

    Carr, Michael H.; McCleese, Daniel J.; Bada, Jeffrey L.; Bogard, Donald D.; Clark, Benton C.; DeVincenzi, Donald; Drake, Michael J.; Nealson, Kenneth H.; Papike, James J.; Race, Margaret S.; hide

    1999-01-01

    In anticipation of the return of samples from Mars toward the end of the first decade of the next century, NASA's Office of Space Sciences chartered a panel to examine how Mars samples should be handled. The panel was to make recommendations in three areas: (1) sample collection and transport back to Earth; (2) certification of the samples as nonhazardous; and (3) sample receiving, curation, and distribution. This report summarizes the findings of that panel. The samples should be treated as hazardous until proven otherwise. They are to be sealed within a canister on Mars, and the canister is not to be opened until within a Biosafety Hazard Level 4 (BSL-4) containment facility here on Earth. This facility must also meet or exceed the cleanliness requirements of the Johnson Space Center (JSC) facility for curation of extraterrestrial materials. A containment facility meeting both these requirements does not yet exist. Hazard assessment and life detection experiments are to be done at the containment facility, while geochemical characterization is being performed on a sterilized subset of the samples released to the science community. When and if the samples are proven harmless, they are to be transferred to a curation facility, such as that at JSC.

  20. Chemical Dynamics Simulations of Intermolecular Energy Transfer: Azulene + N2 Collisions.

    PubMed

    Kim, Hyunsik; Paul, Amit K; Pratihar, Subha; Hase, William L

    2016-07-14

    Chemical dynamics simulations were performed to investigate collisional energy transfer from highly vibrationally excited azulene (Az*) in a N2 bath. The intermolecular potential between Az and N2, used for the simulations, was determined from MP2/6-31+G* ab initio calculations. Az* is prepared with an 87.5 kcal/mol excitation energy by using quantum microcanonical sampling, including its 95.7 kcal/mol zero-point energy. The average energy of Az* versus time, obtained from the simulations, shows different rates of Az* deactivation depending on the N2 bath density. Using the N2 bath density and Lennard-Jones collision number, the average energy transfer per collision ⟨ΔEc⟩ was obtained for Az* as it is collisionally relaxed. By comparing ⟨ΔEc⟩ versus the bath density, the single collision limiting density was found for energy transfer. The resulting ⟨ΔEc⟩, for an 87.5 kcal/mol excitation energy, is 0.30 ± 0.01 and 0.32 ± 0.01 kcal/mol for harmonic and anharmonic Az potentials, respectively. For comparison, the experimental value is 0.57 ± 0.11 kcal/mol. During Az* relaxation there is no appreciable energy transfer to Az translation and rotation, and the energy transfer is to the N2 bath.

  1. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing†

    PubMed Central

    Jensen, Erik C.; Stockton, Amanda M.; Chiesl, Thomas N.; Kim, Jungkyu; Bera, Abhisek; Mathies, Richard A.

    2013-01-01

    A digitally programmable microfluidic Automaton consisting of a 2-dimensional array of pneumatically actuated microvalves is programmed to perform new multiscale mixing and sample processing operations. Large (µL-scale) volume processing operations are enabled by precise metering of multiple reagents within individual nL-scale valves followed by serial repetitive transfer to programmed locations in the array. A novel process exploiting new combining valve concepts is developed for continuous rapid and complete mixing of reagents in less than 800 ms. Mixing, transfer, storage, and rinsing operations are implemented combinatorially to achieve complex assay automation protocols. The practical utility of this technology is demonstrated by performing automated serial dilution for quantitative analysis as well as the first demonstration of on-chip fluorescent derivatization of biomarker targets (carboxylic acids) for microchip capillary electrophoresis on the Mars Organic Analyzer. A language is developed to describe how unit operations are combined to form a microfluidic program. Finally, this technology is used to develop a novel microfluidic 6-sample processor for combinatorial mixing of large sets (>26 unique combinations) of reagents. The digitally programmable microfluidic Automaton is a versatile programmable sample processor for a wide range of process volumes, for multiple samples, and for different types of analyses. PMID:23172232

  2. Academic Performance of Community College Transfers: Psychological, Sociodemographic, and Educational Correlates

    ERIC Educational Resources Information Center

    Wang, Xueli

    2012-01-01

    This study focuses on the academic performance of community college transfer students at four-year institutions. It uses a nationally representative sample from the National Education Longitudinal Study of 1988 (NELS: 88/2000) and the Postsecondary Education Transcript Study (PETS). Results from an Ordinary Least Squares regression model suggest…

  3. How Do Transfer Students Perform in Economics? Evidence from Intermediate Macroeconomics

    ERIC Educational Resources Information Center

    Asarta, Carlos J.; Fuess, Scott M., Jr.; Perumal, Andrew

    2013-01-01

    For students taking intermediate-level economics, does it matter where they studied principles of economics? Does transferring college credit influence subsequent academic performance in economics? With a sample covering 1999-2008, the authors analyze in this article a group of nearly 1,000 students taking intermediate macroeconomics at a…

  4. Carrier-phase time transfer.

    PubMed

    Larson, K M; Levine, J

    1999-01-01

    We have conducted several time-transfer experiments using the phase of the GPS carrier rather than the code, as is done in current GPS-based time-transfer systems. Atomic clocks were connected to geodetic GPS receivers; we then used the GPS carrier-phase observations to estimate relative clock behavior at 6-minute intervals. GPS carrier-phase time transfer is more than an order of magnitude more precise than GPS common view time transfer and agrees, within the experimental uncertainty, with two-way satellite time-transfer measurements for a 2400 km baseline. GPS carrier-phase time transfer has a stability of 100 ps, which translates into a frequency uncertainty of about two parts in 10(-15) for an average time of 1 day.

  5. Heat Transfer through a Condensate Droplet on Hydrophobic and Nanostructured Superhydrophobic Surfaces.

    PubMed

    Chavan, Shreyas; Cha, Hyeongyun; Orejon, Daniel; Nawaz, Kashif; Singla, Nitish; Yeung, Yip Fun; Park, Deokgeun; Kang, Dong Hoon; Chang, Yujin; Takata, Yasuyuki; Miljkovic, Nenad

    2016-08-09

    Understanding the fundamental mechanisms governing vapor condensation on nonwetting surfaces is crucial to a wide range of energy and water applications. In this paper, we reconcile classical droplet growth modeling barriers by utilizing two-dimensional axisymmetric numerical simulations to study individual droplet heat transfer on nonwetting surfaces (90° < θa < 170°). Incorporation of an appropriate convective boundary condition at the liquid-vapor interface reveals that the majority of heat transfer occurs at the three phase contact line, where the local heat flux can be up to 4 orders of magnitude higher than at the droplet top. Droplet distribution theory is incorporated to show that previous modeling approaches underpredict the overall heat transfer by as much as 300% for dropwise and jumping-droplet condensation. To verify our simulation results, we study condensed water droplet growth using optical and environmental scanning electron microscopy on biphilic samples consisting of hydrophobic and nanostructured superhydrophobic regions, showing excellent agreement with the simulations for both constant base area and constant contact angle growth regimes. Our results demonstrate the importance of resolving local heat transfer effects for the fundamental understanding and high fidelity modeling of phase change heat transfer on nonwetting surfaces.

  6. Learning Strategies in Matching to Sample: If-then and Configural Learning by Pigeons

    PubMed Central

    Katz, Jeffrey S.; Bodily, Kent D.; Wright, Anthony A.

    2008-01-01

    Pigeons learned a matching-to-sample task with a split training-set design in which half of the stimulus displays were untrained and tested following acquisition. Transfer to the untrained displays along with no novel-stimulus transfer indicated that these pigeons learned the task (partially) via if-then rules. Comparisons to other performance measures indicated that they also partially learned the task via configural learning (learning the gestalt of the whole stimulus display). Differences in the FR-sample requirement (1 vs. 20) had no systematic effect on the type of learning or level of learning obtained. Differences from a previous study (Wright, 1997) are discussed, including the effect of displaying the stimuli vertically (traditional display orientation) or horizontally from the floor. PMID:18079071

  7. Electron, proton and hydrogen-atom transfers in photosynthetic water oxidation.

    PubMed Central

    Tommos, Cecilia

    2002-01-01

    When photosynthetic organisms developed so that they could use water as an electron source to reduce carbon dioxide, the stage was set for efficient proliferation. Algae and plants spread globally and provided the foundation for our atmosphere and for O(2)-based chemistry in biological systems. Light-driven water oxidation is catalysed by photosystem II, the active site of which contains a redox-active tyrosine denoted Y(Z), a tetramanganese cluster, calcium and chloride. In 1995, Gerald Babcock and co-workers presented the hypothesis that photosynthetic water oxidation occurs as a metallo-radical catalysed process. In this model, the oxidized tyrosine radical is generated by coupled proton/electron transfer and re-reduced by abstracting hydrogen atoms from substrate water or hydroxide-ligated to the manganese cluster. The proposed function of Y(Z) requires proton transfer from the tyrosine site upon oxidation. The oxidation mechanism of Y(Z) in an inhibited and O(2)-evolving photosystem II is discussed. Domino-deprotonation from Y(Z) to the bulk solution is shown to be consistent with a variety of data obtained on metal-depleted samples. Experimental data that suggest that the oxidation of Y(Z) in O(2)-evolving samples is coupled to proton transfer in a hydrogen-bonding network are described. Finally, a dielectric-dependent model for the proton release that is associated with the catalytic cycle of photosystem II is discussed. PMID:12437877

  8. Heat transfer fluids containing nanoparticles

    DOEpatents

    Singh, Dileep; Routbort, Jules; Routbort, A.J.; Yu, Wenhua; Timofeeva, Elena; Smith, David S.; France, David M.

    2016-05-17

    A nanofluid of a base heat transfer fluid and a plurality of ceramic nanoparticles suspended throughout the base heat transfer fluid applicable to commercial and industrial heat transfer applications. The nanofluid is stable, non-reactive and exhibits enhanced heat transfer properties relative to the base heat transfer fluid, with only minimal increases in pumping power required relative to the base heat transfer fluid. In a particular embodiment, the plurality of ceramic nanoparticles comprise silicon carbide and the base heat transfer fluid comprises water and water and ethylene glycol mixtures.

  9. Property transfer

    NASA Image and Video Library

    2011-08-24

    Stennis Space Center Director Patrick Scheuermann (l) addresses visitors gathered for the official transfer of the former Mississippi Army Ammunition Plant facilities to NASA. The action transferred 1.6 million square feet of facility space, increasing Stennis work facilities by about one-third and setting the stage for years of expansion.

  10. Amino-Acid-Induced Preferential Orientation of Perovskite Crystals for Enhancing Interfacial Charge Transfer and Photovoltaic Performance.

    PubMed

    Shih, Yen-Chen; Lan, Yu-Bing; Li, Chia-Shuo; Hsieh, Hsiao-Chi; Wang, Leeyih; Wu, Chih-I; Lin, King-Fu

    2017-06-01

    Interfacial engineering of perovskite solar cells (PSCs) is attracting intensive attention owing to the charge transfer efficiency at an interface, which greatly influences the photovoltaic performance. This study demonstrates the modification of a TiO 2 electron-transporting layer with various amino acids, which affects charge transfer efficiency at the TiO 2 /CH 3 NH 3 PbI 3 interface in PSC, among which the l-alanine-modified cell exhibits the best power conversion efficiency with 30% enhancement. This study also shows that the (110) plane of perovskite crystallites tends to align in the direction perpendicular to the amino-acid-modified TiO 2 as observed in grazing-incidence wide-angle X-ray scattering of thin CH 3 NH 3 PbI 3 perovskite film. Electrochemical impedance spectroscopy reveals less charge transfer resistance at the TiO 2 /CH 3 NH 3 PbI 3 interface after being modified with amino acids, which is also supported by the lower intensity of steady-state photoluminescence (PL) and the reduced PL lifetime of perovskite. In addition, based on the PL measurement with excitation from different side of the sample, amino-acid-modified samples show less surface trapping effect compared to the sample without modification, which may also facilitate charge transfer efficiency at the interface. The results suggest that appropriate orientation of perovskite crystallites at the interface and trap-passivation are the niche for better photovoltaic performance. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Isotope effects associated with tunneling and double proton transfer in the hydrogen bonds of benzoic acid

    NASA Astrophysics Data System (ADS)

    Xue, Q.; Horsewill, A. J.; Johnson, M. R.; Trommsdorff, H. P.

    2004-06-01

    The isotope effects associated with double proton transfer in the hydrogen bonds of benzoic acid (BA) dimers have been measured using field-cycling 1H NMR relaxometry and quasielastic neutron scattering. By studying mixed isotope (hydrogen and deuterium) samples, the dynamics of three isotopologues, BA-HH, BA-HD, and BA-DD, have been investigated. Low temperature measurements provide accurate measurements of the incoherent tunneling rate, k0. This parameter scales accurately with the mass number, m, according to the formula k0=(E/m)e-F√m providing conclusive evidence that the proton transfer process is a strongly correlated motion of two hydrons. Furthermore, we conclude that the tunneling pathway is the same for the three isotopologue species. Measurements at higher temperatures illuminate the through barrier processes that are mediated via intermediate or excited vibrational states. In parallel with the investigation of proton transfer dynamics, the theoretical and experimental aspects of studying spin-lattice relaxation in single crystals of mixed isotope samples are investigated in depth. Heteronuclear dipolar interactions between 1H and 2H isotopes contribute significantly to the overall proton spin-lattice relaxation and it is shown that these must be modeled correctly to obtain accurate values for the proton transfer rates. Since the sample used in the NMR measurements was a single crystal, full account of the orientation dependence of the spin-lattice relaxation with respect to the applied B field was incorporated into the data analysis.

  12. Large-scale studies on the transferability of general problem-solving skills and the pedagogic potential of physics

    NASA Astrophysics Data System (ADS)

    Mashood, K. K.; Singh, Vijay A.

    2013-09-01

    Research suggests that problem-solving skills are transferable across domains. This claim, however, needs further empirical substantiation. We suggest correlation studies as a methodology for making preliminary inferences about transfer. The correlation of the physics performance of students with their performance in chemistry and mathematics in highly competitive problem-solving examinations was studied using a massive database. The sample sizes ranged from hundreds to a few hundred thousand. Encouraged by the presence of significant correlations, we interviewed 20 students to explore the pedagogic potential of physics in imparting transferable problem-solving skills. We report strategies and practices relevant to physics employed by these students which foster transfer.

  13. Technology transfer within the government

    NASA Technical Reports Server (NTRS)

    Christensen, Carissa Bryce

    1992-01-01

    The report of a workshop panel concerned with technology transfer within the government is presented. The suggested subtopics for the panel were as follows: (1) transfer from non-NASA U.S. government technology developers to NASA space missions/programs; and (2) transfer from NASA to other U.S. government civil space mission programs. Two presentations were made to the panel: Roles/Value of Early Strategic Planning Within the Space Exploration Initiative (SEI) to Facilitate Later Technology Transfer To and From Industry; and NOAA Satellite Programs and Technology Requirements. The panel discussion addresses the following major issues: DOD/NASA cooperation; alternative mechanisms for interagency communication and interactions; current technology transfer relationships among federal research agencies, and strategies for improving this transfer; technology transfer mechanisms appropriate to intragovernment transfer; the importance of industry as a technology transfer conduit; and measures of merit.

  14. Toward Construct Validation of a Transfer Climate Instrument. [and] Improving Positive Transfer: A Test of Relapse Prevention Training on Transfer Outcomes.

    ERIC Educational Resources Information Center

    Holton, Elwood F., III; And Others

    1997-01-01

    Includes "Toward Construct Validation of a Transfer Climate Instrument" (Holton et al.); "Improving Positive Transfer: A Test of Relapse Prevention Training on Transfer Outcomes" (Burke); "Invited Reaction: Progress or Relapse?" (Newstrom); "Invited Reaction: Theory, Research, and Practice" (Tang);…

  15. Learning, Intention to Transfer and Transfer in Executive Education

    ERIC Educational Resources Information Center

    Culpin, Victoria; Eichenberg, Timm; Hayward, Ian; Abraham, Priya

    2014-01-01

    The main aim of this study was to understand the relationship between self-reported "intention" to transfer and self-reported "actual" transfer within a population of middle and senior executives on an executive education programme. A secondary objective was to consider the relationship between these qualitative self-reports of…

  16. 7 CFR 932.54 - Transfers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., the transferring handler shall comply with all applicable regulations up to the time of such transfer... 7 Agriculture 8 2014-01-01 2014-01-01 false Transfers. 932.54 Section 932.54 Agriculture... Regulating Handling Regulations § 932.54 Transfers. Transfers within the area of olives from one handler to...

  17. 7 CFR 932.54 - Transfers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., the transferring handler shall comply with all applicable regulations up to the time of such transfer... 7 Agriculture 8 2010-01-01 2010-01-01 false Transfers. 932.54 Section 932.54 Agriculture... Regulating Handling Regulations § 932.54 Transfers. Transfers within the area of olives from one handler to...

  18. 7 CFR 932.54 - Transfers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., the transferring handler shall comply with all applicable regulations up to the time of such transfer... 7 Agriculture 8 2012-01-01 2012-01-01 false Transfers. 932.54 Section 932.54 Agriculture... Regulating Handling Regulations § 932.54 Transfers. Transfers within the area of olives from one handler to...

  19. 7 CFR 932.54 - Transfers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., the transferring handler shall comply with all applicable regulations up to the time of such transfer... 7 Agriculture 8 2013-01-01 2013-01-01 false Transfers. 932.54 Section 932.54 Agriculture... Regulating Handling Regulations § 932.54 Transfers. Transfers within the area of olives from one handler to...

  20. 7 CFR 932.54 - Transfers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., the transferring handler shall comply with all applicable regulations up to the time of such transfer... 7 Agriculture 8 2011-01-01 2011-01-01 false Transfers. 932.54 Section 932.54 Agriculture... Regulating Handling Regulations § 932.54 Transfers. Transfers within the area of olives from one handler to...

  1. Coupled heat transfer model and experiment study of semitransparent barrier materials in aerothermal environment

    NASA Astrophysics Data System (ADS)

    Wang, Da-Lin; Qi, Hong

    Semi-transparent materials (such as IR optical windows) are widely used for heat protection or transfer, temperature and image measurement, and safety in energy , space, military, and information technology applications. They are used, for instance, ceramic coatings for thermal barriers of spacecrafts or gas turbine blades, and thermal image observation under extreme or some dangerous environments. In this paper, the coupled conduction and radiation heat transfer model is established to describe temperature distribution of semitransparent thermal barrier medium within the aerothermal environment. In order to investigate this numerical model, one semi-transparent sample with black coating was considered, and photothermal properties were measured. At last, Finite Volume Method (FVM) was used to solve the coupled model, and the temperature responses from the sample surfaces were obtained. In addition, experiment study was also taken into account. In the present experiment, aerodynamic heat flux was simulated by one electrical heater, and two experiment cases were designed in terms of the duration of aerodynamic heating. One case is that the heater irradiates one surface of the sample continually until the other surface temperature up to constant, and the other case is that the heater works only 130 s. The surface temperature responses of these two cases were recorded. Finally, FVM model of the coupling conduction-radiation heat transfer was validated based on the experiment study with relative error less than 5%.

  2. Ultra high vacuum test setup for electron gun

    NASA Astrophysics Data System (ADS)

    Pandiyar, M. L.; Prasad, M.; Jain, S. K.; Kumar, R.; Hannurkar, P. R.

    2008-05-01

    Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of cathode surface material at high temperature studies will further help in design and development of high power electron gun The UHV electron gun test setup consists of Turbo Molecular Pump (TMP), Sputter Ion Pump (SIP), pressure gauge, high voltage and cathode power supplies, current measurement device, solenoid magnet and its power supply, residual gas analyser etc. The ultimate vacuum less than 2×10-9 mbar was achieved. This paper describes the UHV test setup for electron gun testing.

  3. Cost-effectiveness analysis of different embryo transfer strategies in England.

    PubMed

    Dixon, S; Faghih Nasiri, F; Ledger, W L; Lenton, E A; Duenas, A; Sutcliffe, P; Chilcott, J B

    2008-05-01

    The objective of this study was to assess the cost-effectiveness of different embryo transfer strategies for a single cycle when two embryos are available, and taking the NHS cost perspective. Cost-effectiveness model. Five in vitro fertilisation (IVF) centres in England between 2003/04 and 2004/05. Women with two embryos available for transfer in three age groups (<30, 30-35 and 36-39 years). A decision analytic model was constructed using observational data collected from a sample of fertility centres in England. Costs and adverse outcomes are estimated up to 5 years after the birth. Incremental cost per live birth was calculated for different embryo transfer strategies and for three separate age groups: less than 30, 30-35 and 36-39 years. Premature birth, neonatal intensive care unit admissions and days, cerebral palsy and incremental cost-effectiveness ratios. Single fresh embryo transfer (SET) plus frozen single embryo transfer (fzSET) is the more costly in terms of IVF costs, but the lower rates of multiple births mean that in terms of total costs, it is less costly than double embryo transfer (DET). Adverse events increase when moving from SET to SET+fzSET to DET. The probability of SET+fzSET being cost-effective decreases with age. When SET is included in the analysis, SET+fzSET no longer becomes a cost-effective option at any threshold value for all age groups studied. The analyses show that the choice of embryo transfer strategy is a function of four factors: the age of the mother, the relevance of the SET option, the value placed on a live birth and the relative importance placed on adverse outcomes. For each patient group, the choice of strategy is a trade-off between the value placed on a live birth and cost.

  4. Proton transfer to charged platinum electrodes. A molecular dynamics trajectory study.

    PubMed

    Wilhelm, Florian; Schmickler, Wolfgang; Spohr, Eckhard

    2010-05-05

    A recently developed empirical valence bond (EVB) model for proton transfer on Pt(111) electrodes (Wilhelm et al 2008 J. Phys. Chem. C 112 10814) has been applied in molecular dynamics (MD) simulations of a water film in contact with a charged Pt surface. A total of seven negative surface charge densities σ between -7.5 and -18.9 µC cm(-2) were investigated. For each value of σ, between 30 and 84 initial conditions of a solvated proton within a water slab were sampled, and the trajectories were integrated until discharge of a proton occurred on the charged surfaces. We have calculated the mean rates for discharge and for adsorption of solvated protons within the adsorbed water layer in contact with the metal electrode as a function of surface charge density. For the less negative values of σ we observe a Tafel-like exponential increase of discharge rate with decreasing σ. At the more negative values this exponential increase levels off and the discharge process is apparently transport limited. Mechanistically, the Tafel regime corresponds to a stepwise proton transfer: first, a proton is transferred from the bulk into the contact water layer, which is followed by transfer of a proton to the charged surface and concomitant discharge. At the more negative surface charge densities the proton transfer into the contact water layer and the transfer of another proton to the surface and its discharge occur almost simultaneously.

  5. [Pregnancy and delivery with transfer of vitrified blastocysts following trophectoderm biopsy].

    PubMed

    Mátyás, Szabolcs; Varga, Tünde; Kovács, Péter; Kónya, Márton; Rajczy, Klára; Babenko, Éva; Szabó, Barbara; Kaali, G Steven; Szentirmay, Zoltán

    2015-11-01

    Application of preimplantation genetic diagnosis makes it possible to transfer only embryos unaffected by a certain genetic disorder. The authors have applied the combination of trophectoderm biopsy and vitrification in order to detect a monogenic disorder. Previously diagnosed type 1 neurofibromatosis of the woman was the indication for genetic examination. In vitro fertilisation and embryo culture was performed using sequential culture mediums. Seven blastocysts could be sampled on the fifth day and were vitrified subsequently. Two blastocysts turned out to be genetically normal based on the result of genetic examination using polimerase chain reaction. A healthy boy was delivered following the transfer of warmed blastocysts and an uneventful singleton pregnancy.

  6. Near field wireless power transfer using curved relay resonators for extended transfer distance

    NASA Astrophysics Data System (ADS)

    Zhu, D.; Clare, L.; Stark, B. H.; Beeby, S. P.

    2015-12-01

    This paper investigates the performance of a near field wireless power transfer system that uses curved relay resonator to extend transfer distance. Near field wireless power transfer operates based on the near-field electromagnetic coupling of coils. Such a system can transfer energy over a relatively short distance which is of the same order of dimensions of the coupled coils. The energy transfer distance can be increased using flat relay resonators. Recent developments in printing electronics and e-textiles have seen increasing demand of embedding electronics into fabrics. Near field wireless power transfer is one of the most promising methods to power electronics on fabrics. The concept can be applied to body-worn textiles by, for example, integrating a transmitter coil into upholstery, and a flexible receiver coil into garments. Flexible textile coils take on the shape of the supporting materials such as garments, and therefore curved resonator and receiver coils are investigated in this work. Experimental results showed that using curved relay resonator can effectively extend the wireless power transfer distance. However, as the curvature of the coil increases, the performance of the wireless power transfer, especially the maximum received power, deteriorates.

  7. Mass transfer inside a flux hood for the sampling of gaseous emissions from liquid surfaces - Experimental assessment and emission rate rescaling

    NASA Astrophysics Data System (ADS)

    Prata, Ademir A.; Lucernoni, Federico; Santos, Jane M.; Capelli, Laura; Sironi, Selena; Le-Minh, Nhat; Stuetz, Richard M.

    2018-04-01

    This study assesses the mass transfer of compounds inside the US EPA flux hood, one of the enclosure devices most commonly employed for the direct measurement of atmospheric emissions from liquid surfaces in wastewater treatment plants (WWTPs). Experiments comprised the evaporation of water and the volatilisation of a range of volatile organic compounds (VOCs). Special attention was given to the evaluation of the mass transfer coefficients in the microenvironment created by the flux hood and the effects of concentration build up in the hood's headspace. The VOCs emission rates and the water evaporation rates generally increased with the sweep air flow rate, as did the mass transfer coefficients for all compounds. The emission of compounds whose volatilisation is significantly influenced by the gas phase was greatly affected by concentration build up, whereas this effect was not significant for liquid phase-controlled compounds. The gas-film mass transfer coefficient (kG) estimated inside the US EPA flux hood was of the same order as the respective kG reported in the literature for wind tunnel-type devices, but the emission rates measured by the flux hood can be expected to be lower, due to the concentration build-up. Compared against an emission model for the passive surfaces in WWTPs, the mass transfer of acetic acid (representing a gas phase-dominated compound) inside the US EPA flux hood was equivalent to conditions of wind speeds at 10 m height (U10) of 0.27, 0.51 and 0.99 m s-1, respectively, for sweep air flow rates of 2, 5 and 10 L min-1. On the other hand, for higher wind speeds, the emission rates of gas phase-controlled compounds obtained with the flux hood can be considerably underestimated: for instance, at U10 = 5 m s-1, the emission rates of acetic acid inside the flux hood would be approximately 23, 12 and 6 times lower than the emission rates in the field, for sweep air flow rates of 2, 5 and 10 L min-1, respectively. A procedure is presented in

  8. Dual analyzer system for surface analysis dedicated for angle-resolved photoelectron spectroscopy at liquid surfaces and interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niedermaier, Inga; Kolbeck, Claudia; Steinrück, Hans-Peter

    The investigation of liquid surfaces and interfaces with the powerful toolbox of ultra-high vacuum (UHV)-based surface science techniques generally has to overcome the issue of liquid evaporation within the vacuum system. In the last decade, however, new classes of liquids with negligible vapor pressure at room temperature—in particular, ionic liquids (ILs)—have emerged for surface science studies. It has been demonstrated that particularly angle-resolved X-ray Photoelectron Spectroscopy (ARXPS) allows for investigating phenomena that occur at gas-liquid and liquid-solid interfaces on the molecular level. The results are not only relevant for IL systems but also for liquids in general. In all ofmore » these previous ARXPS studies, the sample holder had to be tilted in order to change the polar detection angle of emitted photoelectrons, which restricted the liquid systems to very thin viscous IL films coating a flat solid support. We now report on the concept and realization of a new and unique laboratory “Dual Analyzer System for Surface Analysis (DASSA)” which enables fast ARXPS, UV photoelectron spectroscopy, imaging XPS, and low-energy ion scattering at the horizontal surface plane of macroscopically thick non-volatile liquid samples. It comprises a UHV chamber equipped with two electron analyzers mounted for simultaneous measurements in 0° and 80° emission relative to the surface normal. The performance of DASSA on a first macroscopic liquid system will be demonstrated.« less

  9. A combined model of heat and mass transfer for the in situ extraction of volatile water from lunar regolith

    NASA Astrophysics Data System (ADS)

    Reiss, P.

    2018-05-01

    Chemical analysis of lunar soil samples often involves thermal processing to extract their volatile constituents, such as loosely adsorbed water. For the characterization of volatiles and their bonding mechanisms it is important to determine their desorption temperature. However, due to the low thermal diffusivity of lunar regolith, it might be difficult to reach a uniform heat distribution in a sample that is larger than only a few particles. Furthermore, the mass transport through such a sample is restricted, which might lead to a significant delay between actual desorption and measurable outgassing of volatiles from the sample. The entire volatiles extraction process depends on the dynamically changing heat and mass transfer within the sample, and is influenced by physical parameters such as porosity, tortuosity, gas density, temperature and pressure. To correctly interpret measurements of the extracted volatiles, it is important to understand the interaction between heat transfer, sorption, and gas transfer through the sample. The present paper discusses the molecular kinetics and mechanisms that are involved in the thermal extraction process and presents a combined parametrical computation model to simulate this process. The influence of water content on the gas diffusivity and thermal diffusivity is discussed and the issue of possible resorption of desorbed molecules within the sample is addressed. Based on the multi-physical computation model, a case study for the ProSPA instrument for in situ analysis of lunar volatiles is presented, which predicts relevant dynamic process parameters, such as gas pressure and process duration.

  10. The transfer of NIR calibrations for undried grass silage from the laboratory to on-site instruments: comparison of two approaches.

    PubMed

    Soldado, A; Fearn, T; Martínez-Fernández, A; de la Roza-Delgado, B

    2013-02-15

    As a first step in a project whose aim is to implement near infrared (NIR) analysis of animal feed on the farm, the present work has examined the possibility of transferring undried grass silage calibrations for dry matter, crude protein, and neutral detergent fiber from a dispersive laboratory NIR instrument (Foss NIRSystem 6500) to a diode array on-site NIR instrument (Zeiss Corona 45 visNIR 1.7). Because the samples are complex and heterogeneous and have high humidity levels it is not easy to establish good calibrations, and it is even more of a challenge to transfer them. By cutting the spectral range to 1100-1650 nm and treating with first or second derivative followed by standard normal variate (SNV) scatter correction, it was possible to obtain very similar spectra from the two instruments. To make the transfer, two approaches were tried. Simply correcting the Corona spectra by subtracting the mean difference spectrum from a transfer set met with only limited success. Making a calibration on the Foss using a calibration set of 503 samples with spectra orthogonalized to the all the difference spectra in the transfer set of 10 samples resulted in a successful transfer for all three calibrations, as judged by performance on two prediction sets of size 22 and 29. Measuring 5 replicate subsamples with the Corona allows it to see a similar surface area to that of 3 replicates in the Foss transport cell, and it is suggested that this is an appropriate level of replication for the Corona. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Phospholipid transfer protein is present in human tear fluid.

    PubMed

    Jauhiainen, Matti; Setälä, Niko L; Ehnholm, Christian; Metso, Jari; Tervo, Timo M T; Eriksson, Ove; Holopainen, Juha M

    2005-06-07

    The human tear fluid film consists of a superficial lipid layer, an aqueous middle layer, and a hydrated mucin layer located next to the corneal epithelium. The superficial lipid layer protects the eye from drying and is composed of polar and neutral lipids provided by the meibomian glands. Excess accumulation of lipids in the tear film may lead to drying of the corneal epithelium. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. To gain insight into the formation of tear film, we investigated whether PLTP and CETP are present in human tear fluid. Tear fluid samples were collected with microcapillaries. The presence of PLTP and CETP was studied in tear fluid by Western blotting, and the PLTP concentration was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. Size-exclusion and heparin-affinity chromatography assessed the molecular form of PLTP. PLTP is present in tear fluid, whereas CETP is not. Quantitative assessment of PLTP by ELISA indicated that the PLTP concentration in tear fluid, 10.9 +/- 2.4 microg/mL, is about 2-fold higher than that in human plasma. PLTP-facilitated phospholipid transfer activity in tears, 15.1 +/- 1.8 micromol mL(-)(1) h(-)(1), was also significantly higher than that measured in plasma. Inactivation of PLTP by heat treatment (+58 degrees C, 60 min) or immunoinhibition abolished the phospholipid transfer activity in tear fluid. Size-exclusion chromatography of tear fluid indicated that PLTP eluted in a position corresponding to a size of 160-170 kDa. Tear fluid PLTP was quantitatively bound to Heparin-Sepharose and could be eluted as a single peak by 0.5 M NaCl. These data indicate that human tear fluid contains catalytically active PLTP protein, which resembles the active form of PLTP present in plasma. The results suggest that PLTP may play a role in the formation of the tear film by supporting phospholipid

  12. Dexter energy transfer pathways

    PubMed Central

    Skourtis, Spiros S.; Liu, Chaoren; Antoniou, Panayiotis; Virshup, Aaron M.; Beratan, David N.

    2016-01-01

    Energy transfer with an associated spin change of the donor and acceptor, Dexter energy transfer, is critically important in solar energy harvesting assemblies, damage protection schemes of photobiology, and organometallic opto-electronic materials. Dexter transfer between chemically linked donors and acceptors is bridge mediated, presenting an enticing analogy with bridge-mediated electron and hole transfer. However, Dexter coupling pathways must convey both an electron and a hole from donor to acceptor, and this adds considerable richness to the mediation process. We dissect the bridge-mediated Dexter coupling mechanisms and formulate a theory for triplet energy transfer coupling pathways. Virtual donor–acceptor charge-transfer exciton intermediates dominate at shorter distances or higher tunneling energy gaps, whereas virtual intermediates with an electron and a hole both on the bridge (virtual bridge excitons) dominate for longer distances or lower energy gaps. The effects of virtual bridge excitons were neglected in earlier treatments. The two-particle pathway framework developed here shows how Dexter energy-transfer rates depend on donor, bridge, and acceptor energetics, as well as on orbital symmetry and quantum interference among pathways. PMID:27382185

  13. Dexter energy transfer pathways.

    PubMed

    Skourtis, Spiros S; Liu, Chaoren; Antoniou, Panayiotis; Virshup, Aaron M; Beratan, David N

    2016-07-19

    Energy transfer with an associated spin change of the donor and acceptor, Dexter energy transfer, is critically important in solar energy harvesting assemblies, damage protection schemes of photobiology, and organometallic opto-electronic materials. Dexter transfer between chemically linked donors and acceptors is bridge mediated, presenting an enticing analogy with bridge-mediated electron and hole transfer. However, Dexter coupling pathways must convey both an electron and a hole from donor to acceptor, and this adds considerable richness to the mediation process. We dissect the bridge-mediated Dexter coupling mechanisms and formulate a theory for triplet energy transfer coupling pathways. Virtual donor-acceptor charge-transfer exciton intermediates dominate at shorter distances or higher tunneling energy gaps, whereas virtual intermediates with an electron and a hole both on the bridge (virtual bridge excitons) dominate for longer distances or lower energy gaps. The effects of virtual bridge excitons were neglected in earlier treatments. The two-particle pathway framework developed here shows how Dexter energy-transfer rates depend on donor, bridge, and acceptor energetics, as well as on orbital symmetry and quantum interference among pathways.

  14. Transfer of Metals in Food Chain: An Example with Copper and Lettuce

    NASA Astrophysics Data System (ADS)

    Vincevica-Gaile, Zane; Klavins, Maris

    2012-12-01

    Present study investigated the possible transfer of metals in the food chain (from soil to edible plants). The experiment was done with lettuce Lactuca sativa grown in different types of soil contaminated with copper (Cu2+) in various concentrations, with or without addition of humic substances. The highest content of copper was detected in lettuce samples grown in soils with lower levels of organic matter, thus indicating the importance of soil organics in metal transfer routes and accumulation rates in plants. It was found that copper accumulation in lettuce grown in contaminated soils can be significantly reduced by the addition of humic substances.

  15. Block Transfer Handbook: Constructing and Negotiating Block Transfer Agreements.

    ERIC Educational Resources Information Center

    Finlay, Finola

    The purpose of this handbook is to provide resources for institutions or articulation committees who are engaged in the task of investigating the feasibility of block transfer agreements. Block transfer is the process whereby a block of credits is granted to students who have successfully completed a certificate, diploma, or cluster of courses…

  16. A novel hybrid scattering order-dependent variance reduction method for Monte Carlo simulations of radiative transfer in cloudy atmosphere

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Cui, Shengcheng; Yang, Jun; Gao, Haiyang; Liu, Chao; Zhang, Zhibo

    2017-03-01

    We present a novel hybrid scattering order-dependent variance reduction method to accelerate the convergence rate in both forward and backward Monte Carlo radiative transfer simulations involving highly forward-peaked scattering phase function. This method is built upon a newly developed theoretical framework that not only unifies both forward and backward radiative transfer in scattering-order-dependent integral equation, but also generalizes the variance reduction formalism in a wide range of simulation scenarios. In previous studies, variance reduction is achieved either by using the scattering phase function forward truncation technique or the target directional importance sampling technique. Our method combines both of them. A novel feature of our method is that all the tuning parameters used for phase function truncation and importance sampling techniques at each order of scattering are automatically optimized by the scattering order-dependent numerical evaluation experiments. To make such experiments feasible, we present a new scattering order sampling algorithm by remodeling integral radiative transfer kernel for the phase function truncation method. The presented method has been implemented in our Multiple-Scaling-based Cloudy Atmospheric Radiative Transfer (MSCART) model for validation and evaluation. The main advantage of the method is that it greatly improves the trade-off between numerical efficiency and accuracy order by order.

  17. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  18. Articulation, College Transfer, and Academic Success: Northern Virginia Community College Transfer Students and Post-Transfer Success at George Mason University.

    ERIC Educational Resources Information Center

    Solomon, Irwin E.

    This 1993-1997 study had two objectives: to inquire into the post-transfer academic at a four-year university, and to answer the call for continued research into articulation and transfer. The author found that (1) a group of 561 Northern Virginia Community College (NVCC) students who transferred to George Mason University (GMU) over a 5-year…

  19. When Creativity Met Transfer: Increasing Creativity and Transfer by Controlling the Styles of Processing

    ERIC Educational Resources Information Center

    Kaniel, Shlomo

    2013-01-01

    The primary purpose of this article is to combine both transfer of learning (hereafter, transfer) and creativity into similar processes that can increase the products of transfer and creativity. Both transfer and creativity operate within reciprocal relationships between memory storage and working memory. Moreover, they are also based on moving…

  20. How Much Flux does a Flux Transfer Event Transfer?

    NASA Astrophysics Data System (ADS)

    Fear, R. C.; Trenchi, L.; Coxon, J.; Milan, S. E.

    2016-12-01

    Flux transfer events are bursts of reconnection at the dayside magnetopause, which give rise to characteristic signatures that are observed by a range of magnetospheric/ionospheric instrumentation. Spacecraft situated near the magnetopause observe a bipolar variation in the component of the magnetic field normal to the magnetopause (BN); auroral instrumentation (either ground- or space-based) observe poleward moving auroral forms which indicate the convection of newly-opened flux into the polar cap, and ionospheric radars similarly observe pulsed ionospheric flows or poleward moving radar auroral forms. One outstanding problem is the fact that there is a fundamental mismatch between the estimates of the flux that is opened by each flux transfer event - in other words, their overall significance in the Dungey cycle. Spacecraft-based estimates of the flux content of individual FTEs correspond to each event transferring flux equivalent to approximately 1% of the open flux in the magnetosphere, whereas studies based on global-scale radar and auroral observations suggest this figure could be more like 10%. In the former case, flux transfer events would be a minor detail in the Dungey cycle, but in the latter they could be its main driver. We present observations of a conjunction between flux transfer event signatures observed by the Cluster spacecraft, and pulsed ionospheric flows observed by the SuperDARN network on the 8th February 2002. Over the course of an hour, a similar number of FTE signatures were observed by Cluster (at 13 MLT) and the Prince George radar (at 7 MLT). We argue that the reason for the existing mismatch in flux estimates is that implicit assumptions about flux transfer event structure lead to a major underestimate of the flux content based on spacecraft observations. If these assumptions are removed, a much better match is found.

  1. System and method for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos

    2014-01-28

    A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

  2. Failure of 307 basin transfer line and resultant ground contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denham, D.H.

    1970-01-01

    A leak of apparently long duration was discovered on December 9, 1965, in the transfer line from the 307 retention basins to the 340 contaminated waste system during the transfer of liquid from one of the 307 basins. This line was designed to carry only mildly-contaminated retention system waste. However, the uncovered line suggests that, over a period of time, the bottom half of the carbon steel transition section between the transfer line and the 340 contaminated waste system was corroded out. This permitted the highly contaminated waste to percolate into the soil beneath the missing pipe section. Since neithermore » the duration of leakage nor the exact origin or nature of the contaminants were known, this study was undertaken to: (1) estimate the amount of radioactivity released; (2) document its location with respect to the 340 Area and to the underlying groundwater; and (3) investigate its potential environmental impact. Soil samples were collected to determine the approximate location and quantity of each of the radionuclides which had leaked to the soil. One-digit accuracy was deemed sufficient to decide what, if any, action would be required. The findings from the several exploratory holes drilled at and adjacent to the site of the corroded transfer line are reported. (auth)« less

  3. Filtering Non-Linear Transfer Functions on Surfaces.

    PubMed

    Heitz, Eric; Nowrouzezahrai, Derek; Poulin, Pierre; Neyret, Fabrice

    2014-07-01

    Applying non-linear transfer functions and look-up tables to procedural functions (such as noise), surface attributes, or even surface geometry are common strategies used to enhance visual detail. Their simplicity and ability to mimic a wide range of realistic appearances have led to their adoption in many rendering problems. As with any textured or geometric detail, proper filtering is needed to reduce aliasing when viewed across a range of distances, but accurate and efficient transfer function filtering remains an open problem for several reasons: transfer functions are complex and non-linear, especially when mapped through procedural noise and/or geometry-dependent functions, and the effects of perspective and masking further complicate the filtering over a pixel's footprint. We accurately solve this problem by computing and sampling from specialized filtering distributions on the fly, yielding very fast performance. We investigate the case where the transfer function to filter is a color map applied to (macroscale) surface textures (like noise), as well as color maps applied according to (microscale) geometric details. We introduce a novel representation of a (potentially modulated) color map's distribution over pixel footprints using Gaussian statistics and, in the more complex case of high-resolution color mapped microsurface details, our filtering is view- and light-dependent, and capable of correctly handling masking and occlusion effects. Our approach can be generalized to filter other physical-based rendering quantities. We propose an application to shading with irradiance environment maps over large terrains. Our framework is also compatible with the case of transfer functions used to warp surface geometry, as long as the transformations can be represented with Gaussian statistics, leading to proper view- and light-dependent filtering results. Our results match ground truth and our solution is well suited to real-time applications, requires only a few

  4. Active Prior Tactile Knowledge Transfer for Learning Tactual Properties of New Objects

    PubMed Central

    Feng, Di

    2018-01-01

    Reusing the tactile knowledge of some previously-explored objects (prior objects) helps us to easily recognize the tactual properties of new objects. In this paper, we enable a robotic arm equipped with multi-modal artificial skin, like humans, to actively transfer the prior tactile exploratory action experiences when it learns the detailed physical properties of new objects. These experiences, or prior tactile knowledge, are built by the feature observations that the robot perceives from multiple sensory modalities, when it applies the pressing, sliding, and static contact movements on objects with different action parameters. We call our method Active Prior Tactile Knowledge Transfer (APTKT), and systematically evaluated its performance by several experiments. Results show that the robot improved the discrimination accuracy by around 10% when it used only one training sample with the feature observations of prior objects. By further incorporating the predictions from the observation models of prior objects as auxiliary features, our method improved the discrimination accuracy by over 20%. The results also show that the proposed method is robust against transferring irrelevant prior tactile knowledge (negative knowledge transfer). PMID:29466300

  5. Radionuclides in mushrooms and soil-to-mushroom transfer factors in certain areas of China.

    PubMed

    Tuo, Fei; Zhang, Jing; Li, Wenhong; Yao, Shuaimo; Zhou, Qiang; Li, Zeshu

    2017-12-01

    Activity concentrations of 238 U, 226 Ra, 228 Ra, 137 Cs and 40 K in 64 mushroom samples collected in China from Yunnan, Fujian and Heilongjiang Provinces, were measured. Gamma-ray emissions were determined by using high-purity germanium (HPGe) γ spectrometry. The range of concentrations (Bq kg -1 dry weight) for 238 U, 226 Ra, 228 Ra, 137 Cs and 40 K in all investigated mushroom samples were from 0.12 to 12, 0.05 to 7.5, 0.14 to 14, MDC(<0.01) to 339, and 396 to 1880, respectively. Activity concentrations of 137 Cs in mushrooms showed some variation between species sampled at the same site. To calculate soil to mushroom transfer factors, levels of radionuclide in 15 paired soil samples and mushrooms were also investigated. The median transfer factors for 238 U, 226 Ra, 228 Ra, 137 Cs and 40 K were 8.32 × 10 -2 , 3.03 × 10 -2 , 6.69 × 10 -2 , 0.40 and 1.19, respectively. The results were compared with values of other areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Chemical and Solar Electric Propulsion Systems Analyses for Mars Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Donahue, Benjamin B.; Green, Shaun E.; Coverstone, Victoria L.; Woo, Byoungsam

    2004-01-01

    Conceptual in-space transfer stages, including those utilizing solar electric propulsion, chemical propulsion, and chemical propulsion with aerobraking or aerocapture assist at Mars, were evaluated. Roundtrip Mars sample return mission vehicles were analyzed to determine how specific system technology selections influence payload delivery capability. Results show how specific engine, thruster, propellant, capture mode, trip time and launch vehicle technology choices would contribute to increasing payload or decreasing the size of the required launch vehicles. Heliocentric low-thrust trajectory analyses for Solar Electric Transfer were generated with the SEPTOP code.

  7. About the Role of the Bottleneck/Cork Interface on Oxygen Transfer.

    PubMed

    Lagorce-Tachon, Aurélie; Karbowiak, Thomas; Paulin, Christian; Simon, Jean-Marc; Gougeon, Régis D; Bellat, Jean-Pierre

    2016-09-07

    The transfer of oxygen through a corked bottleneck was investigated using a manometric technique. First, the effect of cork compression on oxygen transfer was evaluated without considering the glass/cork interface. No significant effect of cork compression (at 23% strain, corresponding to the compression level of cork in a bottleneck for still wines) was noticeable on the effective diffusion coefficient of oxygen. The mean value of the effective diffusion coefficient is equal to 10(-8) m(2) s(-1), with a statistical distribution ranging from 10(-10) to 10(-7) m(2) s(-1), which is of the same order of magnitude as for the non-compressed cork. Then, oxygen transfer through cork compressed in a glass bottleneck was determined to assess the effect of the glass/cork interface. In the particular case of a gradient-imposed diffusion of oxygen through our model corked bottleneck system (dry cork without surface treatment; 200 and ∼0 hPa of oxygen on both sides of the sample), the mean effective diffusion coefficient is of 5 × 10(-7) m(2) s(-1), thus revealing the possible importance of the role of the glass/stopper interface in the oxygen transfer.

  8. Iterative optimization method for design of quantitative magnetization transfer imaging experiments.

    PubMed

    Levesque, Ives R; Sled, John G; Pike, G Bruce

    2011-09-01

    Quantitative magnetization transfer imaging (QMTI) using spoiled gradient echo sequences with pulsed off-resonance saturation can be a time-consuming technique. A method is presented for selection of an optimum experimental design for quantitative magnetization transfer imaging based on the iterative reduction of a discrete sampling of the Z-spectrum. The applicability of the technique is demonstrated for human brain white matter imaging at 1.5 T and 3 T, and optimal designs are produced to target specific model parameters. The optimal number of measurements and the signal-to-noise ratio required for stable parameter estimation are also investigated. In vivo imaging results demonstrate that this optimal design approach substantially improves parameter map quality. The iterative method presented here provides an advantage over free form optimal design methods, in that pragmatic design constraints are readily incorporated. In particular, the presented method avoids clustering and repeated measures in the final experimental design, an attractive feature for the purpose of magnetization transfer model validation. The iterative optimal design technique is general and can be applied to any method of quantitative magnetization transfer imaging. Copyright © 2011 Wiley-Liss, Inc.

  9. A case report in health information exchange for inter-organizational patient transfers.

    PubMed

    Richardson, J E; Malhotra, S; Kaushal, R

    2014-01-01

    To provide a case report of barriers and promoters to implementing a health information exchange (HIE) tool that supports patient transfers between hospitals and skilled nursing facilities. A multi-disciplinary team conducted semi-structured telephone and in-person interviews in a purposive sample of HIE organizational informants and providers in New York City who implemented HIE to share patient transfer information. The researchers conducted grounded theory analysis to identify themes of barriers and promoters and took steps to improve the trustworthiness of the results including vetting from a knowledgeable study participant. Between May and October 2011, researchers recruited 18 participants: informaticians, healthcare administrators, software engineers, and providers from a skilled nursing facility. Subjects perceived the HIE tool's development a success in that it brought together stakeholders who had traditionally not partnered for informatics work, and that they could successfully share patient transfer information between a hospital and a skilled nursing facility. Perceived barriers included lack of hospital stakeholder buy-in and misalignment with clinical workflows that inhibited use of HIE-based patient transfer data. Participants described barriers and promoters in themes related to organizational, technical, and user-oriented issues. The investigation revealed that stakeholders could develop and implement health information technology that technically enables clinicians in both hospitals and skilled nursing facilities to exchange real-time information in support of patient transfers. User level barriers, particularly in the emergency department, should give pause to developers and implementers who plan to use HIE in support of patient transfers. Participants' experiences demonstrate how stakeholders may succeed in developing and piloting an electronic transfer form that relies on HIE to aggregate, communicate, and display relevant patient transfer

  10. Mars Sample Return without Landing on the Surface

    NASA Technical Reports Server (NTRS)

    Jurewicz, A. J. G.; Jones, Steven M.; Yen, A. S.

    2000-01-01

    Many in the science community want a Mars sample return in the near future, with the expectation that it will provide in-depth information, significantly beyond what we know from remote sensing, limited in-situ measurements, and work with Martian meteorites. Certainly, return of samples from the Moon resulted in major advances in our understanding of both the geologic history of our planetary satellite, and its relationship to Earth. Similar scientific insights would be expected from analyses of samples returned from Mars. Unfortunately, Mars-lander sample-return missions have been delayed, for the reason that NASA needs more time to review the complexities and risks associated with that type of mission. A traditional sample return entails a complex transfer-chain, including landing, collection, launch, rendezvous, and the return to Earth, as well as an evaluation of potential biological hazards involved with bringing pristine Martian organics to Earth. There are, however, means of returning scientifically-rich samples from Mars without landing on the surface. This paper discusses an approach for returning intact samples of surface dust, based on known instrument technology, without using an actual Martian lander.

  11. HYDROLYSIS OF MTBE TO TBA IN GROUND WATER SAMPLES WITH HYDROCHLORIC ACID

    EPA Science Inventory

    Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as tert-butyl alcohol (TBA). Because alcohols are miscible or highly soluble in water, alcohols are not efficiently transferred to the gas chromatograph for analysis....

  12. Immediate Biomechanical Implications of Transfer Component Skills Training on Independent Wheelchair Transfers.

    PubMed

    Tsai, Chung-Ying; Boninger, Michael L; Hastings, Jennifer; Cooper, Rory A; Rice, Laura; Koontz, Alicia M

    2016-10-01

    To evaluate the immediate effects of transfer training based on the Transfer Assessment Instrument (TAI) on the upper limb biomechanics during transfers. Pre-post intervention. Biomechanics laboratory. Full-time manual wheelchair users (N=24) performed 5 transfers to a level height bench, while their natural transfer skills were scored using the TAI, and their biomechanical data were recorded. Participants with 2 or more component skill deficits were invited to return to receive personalized transfer training. TAI part 1 summary scores and biomechanical variables calculated at the shoulder, elbow, and wrist joints were compared before and immediately after transfer training. Sixteen of the 24 manual wheelchair users met the criteria for training, and 11 manual wheelchair users came back for the revisit. Their TAI part 1 summary scores improved from 6.31±.98 to 9.92±.25. They had significantly smaller elbow range of motion, shoulder resultant moment, and rates of rise of elbow and wrist resultant forces on their trailing side during transfers after training (P<.05). On the leading side, shoulder maximum internal rotation and elevation angles, and shoulder resultant moments and rates of rise of shoulder resultant force and moment decreased after training (P<.04). The TAI-based training showed short-term beneficial biomechanical effects on wheelchair users' upper limbs, such as better shoulder positioning and lower joint loadings. If the skills are practiced longer-term, they may help protect the upper limbs from developing pain and injuries. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    PubMed

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the

  14. Combined Heat Transfer in High-Porosity High-Temperature Fibrous Insulations: Theory and Experimental Validation

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Cunnington, George R.; Miller, Steve D.; Knutson, Jeffry R.

    2010-01-01

    Combined radiation and conduction heat transfer through various high-temperature, high-porosity, unbonded (loose) fibrous insulations was modeled based on first principles. The diffusion approximation was used for modeling the radiation component of heat transfer in the optically thick insulations. The relevant parameters needed for the heat transfer model were derived from experimental data. Semi-empirical formulations were used to model the solid conduction contribution of heat transfer in fibrous insulations with the relevant parameters inferred from thermal conductivity measurements at cryogenic temperatures in a vacuum. The specific extinction coefficient for radiation heat transfer was obtained from high-temperature steady-state thermal measurements with large temperature gradients maintained across the sample thickness in a vacuum. Standard gas conduction modeling was used in the heat transfer formulation. This heat transfer modeling methodology was applied to silica, two types of alumina, and a zirconia-based fibrous insulation, and to a variation of opacified fibrous insulation (OFI). OFI is a class of insulations manufactured by embedding efficient ceramic opacifiers in various unbonded fibrous insulations to significantly attenuate the radiation component of heat transfer. The heat transfer modeling methodology was validated by comparison with more rigorous analytical solutions and with standard thermal conductivity measurements. The validated heat transfer model is applicable to various densities of these high-porosity insulations as long as the fiber properties are the same (index of refraction, size distribution, orientation, and length). Furthermore, the heat transfer data for these insulations can be obtained at any static pressure in any working gas environment without the need to perform tests in various gases at various pressures.

  15. Flavin Charge Transfer Transitions Assist DNA Photolyase Electron Transfer

    NASA Astrophysics Data System (ADS)

    Skourtis, Spiros S.; Prytkova, Tatiana; Beratan, David N.

    2007-12-01

    This contribution describes molecular dynamics, semi-empirical and ab-initio studies of the primary photo-induced electron transfer reaction in DNA photolyase. DNA photolyases are FADH--containing proteins that repair UV-damaged DNA by photo-induced electron transfer. A DNA photolyase recognizes and binds to cyclobutatne pyrimidine dimer lesions of DNA. The protein repairs a bound lesion by transferring an electron to the lesion from FADH-, upon photo-excitation of FADH- with 350-450 nm light. We compute the lowest singlet excited states of FADH- in DNA photolyase using INDO/S configuration interaction, time-dependent density-functional, and time-dependent Hartree-Fock methods. The calculations identify the lowest singlet excited state of FADH- that is populated after photo-excitation and that acts as the electron donor. For this donor state we compute conformationally-averaged tunneling matrix elements to empty electron-acceptor states of a thymine dimer bound to photolyase. The conformational averaging involves different FADH--thymine dimer confromations obtained from molecular dynamics simulations of the solvated protein with a thymine dimer docked in its active site. The tunneling matrix element computations use INDO/S-level Green's function, energy splitting, and Generalized Mulliken-Hush methods. These calculations indicate that photo-excitation of FADH- causes a π→π* charge-transfer transition that shifts electron density to the side of the flavin isoalloxazine ring that is adjacent to the docked thymine dimer. This shift in electron density enhances the FADH--to-dimer electronic coupling, thus inducing rapid electron transfer.

  16. Reaction Dynamics of Proton-Coupled Electron Transfer from Reduced ZnO Nanocrystals.

    PubMed

    Braten, Miles N; Gamelin, Daniel R; Mayer, James M

    2015-10-27

    The creation of systems that efficiently interconvert chemical and electrical energies will be aided by understanding proton-coupled electron transfers at solution-semiconductor interfaces. Steps in developing that understanding are described here through kinetic studies of reactions of photoreduced colloidal zinc oxide (ZnO) nanocrystals (NCs) with the nitroxyl radical TEMPO. These reactions proceed by proton-coupled electron transfer (PCET) to give the hydroxylamine TEMPOH. They occur on the submillisecond to seconds time scale, as monitored by stopped-flow optical spectroscopy. Under conditions of excess TEMPO, the reactions are multiexponential in character. One of the contributors to this multiexponential kinetics may be a distribution of reactive proton sites. A graphical overlay method shows the reaction to be first order in [TEMPO]. Different electron concentrations in otherwise identical NC samples were achieved by three different methods: differing photolysis times, premixing with an unphotolyzed sample, or prereaction with TEMPO. The reaction velocities were consistently higher for NCs with higher numbers of electrons. For instance, NCs with an average of 2.6 e(-)/NC reacted faster than otherwise identical samples containing ≤1 e(-)/NC. Surprisingly, NC samples with the same average number of electrons but prepared in different ways often had different reaction profiles. These results show that properties beyond electron content determine PCET reactivity of the particles.

  17. Impact of a transfer center on interhospital referrals and transfers to a tertiary care center.

    PubMed

    Southard, Patricia A; Hedges, Jerris R; Hunter, John G; Ungerleider, Ross M

    2005-07-01

    The partnership of faculty physicians and senior clinical hospital administrators in the decision to accept interhospital transfers has not been fully studied. Transfers to academic medical centers on the basis of economics have been of particular concern. To evaluate the impact of joint decision making on transfer acceptance, and to evaluate the basis for decisions to transfer patients to an academic medical center. This was a database study of requested adult interhospital transfers, excluding psychiatric transfers, occurring between January 1, 2003, and December 31, 2003, by using data from a computerized patient-tracking system. Where possible, comparisons with the prior calendar year (i.e., prior to implementation of the administrative review process) were made. Incidence of refusal to accept requested transfers and payer mix of transfer patients were the main outcomes of interest. More than 90% of the adult patients were transferred for conditions that required tertiary care or met Emergency Medical Treatment and Labor Act (EMTALA) requirements. The patient conditions that did not meet tertiary care needs included obstetric patients who did not have prenatal care, patients who had hand and facial trauma, and patients who weighed more than 300 pounds. The payer mix of transfer patients remained stable when using the administrator and physician team to determine acceptance of transfers. During the evaluation period, approximately 91,500 patients statewide lost some level of Medicaid coverage. The value of an administrator and physician team as partners in the interhospital transfer process was demonstrated. Active management of interhospital transfers supports transfer of patients who require tertiary care or who meet EMTALA criteria, thus conserving limited bed capacity and ensuring financial equity, while caring for the uninsured and underinsured patients throughout the state.

  18. Diffusive transfer to membranes as an effective interface between gel electrophoresis and mass spectrometry

    NASA Astrophysics Data System (ADS)

    Ogorzalek Loo, Rachel R.; Mitchell, Charles; Stevenson, Tracy I.; Loo, Joseph A.; Andrews, Philip C.

    1997-12-01

    Diffusive transfer was examined as a blotting method to transfer proteins from polyacrylamide gels to membranes for ultraviolet matrix-assisted laser desorption ionization (MALDI) mass spectrometry. The method is well-suited for transfers from isoelectric focusing (IEF) gels. Spectra have been obtained for 11 pmol of 66 kDa albumin loaded onto an IEF gel and subsequently blotted to polyethylene. Similarly, masses of intact carbonic anhydrase and hemoglobin were obtained from 14 and 20 pmol loadings. This methodology is also compatible with blotting high molecular weight proteins, as seen for 6 pmol of the 150 kDa monoclonal antibody anti-[beta]-galactosidase transferred to Goretex. Polypropylene, Teflon, Nafion and polyvinylidene difluoride (PVDF) also produced good spectra following diffusive transfer. Only analysis from PVDF required that the membrane be kept wet prior to application of matrix. Considerations in mass accuracy for analysis from large-area membranes with continuous extraction and delayed extraction were explored, as were remedies for surface charging. Vapor phase CNBr cleavage was applied to membrane-bound samples for peptide mapping.

  19. DC thermal microscopy: study of the thermal exchange between a probe and a sample

    NASA Astrophysics Data System (ADS)

    Gomès, Séverine; Trannoy, Nathalie; Grossel, Philippe

    1999-09-01

    The Scanning Thermal Microscopic (SThM) probe, a thin Pt resistance wire, is used in the constant force mode of an Atomic Force Microscope (AFM). Thermal signal-distance curves for differing degrees of relative humidity and different surrounding gases demonstrate how heat is transferred from the heated probe to the sample. It is known that water affects atomic force microscopy and thermal measurements; we report here on the variation of the water interaction on the thermal coupling versus the probe temperature. Measurements were taken for several solid materials and show that the predominant heat transfer mechanisms taking part in thermal coupling are dependent on the thermal conductivity of the sample. The results have important implications for any quantitative interpretation of thermal images made in air.

  20. Tendon Transfer Surgery

    MedlinePlus

    ... Transfer Surgery Find a hand surgeon near you. Videos Figures Figure 2: Example of Tendon Transfer surgery ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  1. Turbine heat transfer

    NASA Technical Reports Server (NTRS)

    Rohde, J. E.

    1982-01-01

    Objectives and approaches to research in turbine heat transfer are discussed. Generally, improvements in the method of determining the hot gas flow through the turbine passage is one area of concern, as is the cooling air flow inside the airfoil, and the methods of predicting the heat transfer rates on the hot gas side and on the coolant side of the airfoil. More specific areas of research are: (1) local hot gas recovery temperatures along the airfoil surfaces; (2) local airfoil wall temperature; (3) local hot gas side heat transfer coefficients on the airfoil surfaces; (4) local coolant side heat transfer coefficients inside the airfoils; (5) local hot gas flow velocities and secondary flows at real engine conditions; and (6) local delta strain range of the airfoil walls.

  2. Detector shape in hexagonal sampling grids

    NASA Astrophysics Data System (ADS)

    Baronti, Stefano; Capanni, Annalisa; Romoli, Andrea; Santurri, Leonardo; Vitulli, Raffaele

    2001-12-01

    Recent improvements in CCD technology make hexagonal sampling attractive for practical applications and bring a new interest on this topic. In the following the performances of hexagonal sampling are analyzed under general assumptions and compared with the performances of conventional rectangular sampling. This analysis will take into account both the lattice form (squared, rectangular, hexagonal, and regular hexagonal), and the pixel shape. The analyzed hexagonal grid will not based a-priori on a regular hexagon tessellation, i.e., no constraints will be made on the ratio between the sampling frequencies in the two spatial directions. By assuming an elliptic support for the spectrum of the signal being sampled, sampling conditions will be expressed for a generic hexagonal sampling grid, and a comaprison with the well-known sampling conditions for a comparable rectangular lattice will be performed. Further, by considering for sake of clarity a spectrum with a circular support, the comparison will be performed under the assumption of same number of pixels for unity of surface, and the particular case of regular hexagonal sampling grid will also be considered. Regular hexagonal lattice with regular hexagonal sensitivity shape of the detector elements will result as the best trade-off between the proposed sampling requirement. Concerning the detector shape, the hexagonal is more advantageous than the rectangular. To show that a figure of merit is defined which takes into account that the MTF (modulation transfer function) of a hexagonal detector is not separable, conversely from that of a rectangular detector. As a final result, octagonal shape detectors are compared to those with rectangular and hexagonal shape in the two hypotheses of equal and ideal fill factor, respectively.

  3. Characterization of Volatiles Loss from Soil Samples at Lunar Environments

    NASA Technical Reports Server (NTRS)

    Kleinhenz, Julie; Smith, Jim; Roush, Ted; Colaprete, Anthony; Zacny, Kris; Paulsen, Gale; Wang, Alex; Paz, Aaron

    2017-01-01

    Resource Prospector Integrated Thermal Vacuum Test Program A series of ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations for RP Volatiles loss during sampling operations Hardware performance Sample removal and transfer Concept of operationsInstrumentation5 test campaigns over 5 years have been conducted with RP hardware with advancing hardware designs and additional RP subsystems Volatiles sampling 4 years Using flight-forward regolith sampling hardware, empirically determine volatile retention at lunar-relevant conditions Use data to improve theoretical predictions Determine driving variables for retention Bound water loss potential to define measurement uncertainties. The main goal of this talk is to introduce you to our approach to characterizing volatiles loss for RP. Introduce the facility and its capabilities Overview of the RP hardware used in integrated testing (most recent iteration) Summarize the test variables used thus farReview a sample of the results.

  4. Notes on Earth Atmospheric Entry for Mars Sample Return Missions

    NASA Technical Reports Server (NTRS)

    Rivell, Thomas

    2006-01-01

    The entry of sample return vehicles (SRVs) into the Earth's atmosphere is the subject of this document. The Earth entry environment for vehicles, or capsules, returning from the planet Mars is discussed along with the subjects of dynamics, aerodynamics, and heat transfer. The material presented is intended for engineers and scientists who do not have strong backgrounds in aerodynamics, aerothermodynamics and flight mechanics. The document is not intended to be comprehensive and some important topics are omitted. The topics considered in this document include basic principles of physics (fluid mechanics, dynamics and heat transfer), chemistry and engineering mechanics. These subjects include: a) fluid mechanics (aerodynamics, aerothermodynamics, compressible fluids, shock waves, boundary layers, and flow regimes from subsonic to hypervelocity; b) the Earth s atmosphere and gravity; c) thermal protection system design considerations; d) heat and mass transfer (convection, radiation, and ablation); e) flight mechanics (basic rigid body dynamics and stability); and f) flight- and ground-test requirements; and g) trajectory and flow simulation methods.

  5. Enzymatic Kinetic Isotope Effects from First-Principles Path Sampling Calculations.

    PubMed

    Varga, Matthew J; Schwartz, Steven D

    2016-04-12

    In this study, we develop and test a method to determine the rate of particle transfer and kinetic isotope effects in enzymatic reactions, specifically yeast alcohol dehydrogenase (YADH), from first-principles. Transition path sampling (TPS) and normal mode centroid dynamics (CMD) are used to simulate these enzymatic reactions without knowledge of their reaction coordinates and with the inclusion of quantum effects, such as zero-point energy and tunneling, on the transferring particle. Though previous studies have used TPS to calculate reaction rate constants in various model and real systems, it has not been applied to a system as large as YADH. The calculated primary H/D kinetic isotope effect agrees with previously reported experimental results, within experimental error. The kinetic isotope effects calculated with this method correspond to the kinetic isotope effect of the transfer event itself. The results reported here show that the kinetic isotope effects calculated from first-principles, purely for barrier passage, can be used to predict experimental kinetic isotope effects in enzymatic systems.

  6. Student Transferability Study Group Report.

    ERIC Educational Resources Information Center

    Kentucky Council on Public Higher Education, Frankfort.

    Data regarding transfer and non-transfer students who graduated from four representative Kentucky universities were studied with focus on three issues: program articulation, transfer of credits between different types of postsecondary institutions, and types of potential transfer students. The following problems were revealed: the lack of adequate…

  7. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.

    PubMed

    Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow

    2015-11-01

    The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Development of a reaction cell for in-situ/operando studies of surface of a catalyst under a reaction condition and during catalysis.

    PubMed

    Nguyen, Luan; Tao, Franklin Feng

    2016-06-01

    Tracking surface chemistry of a catalyst during catalysis is significant for fundamental understanding of catalytic performance of the catalyst since it allows for establishing an intrinsic correlation between surface chemistry of a catalyst at its working status and its corresponding catalytic performance. Ambient pressure X-ray photoelectron spectroscopy can be used for in-situ studies of surfaces of different materials or devices in a gas. To simulate the gaseous environment of a catalyst in a fixed-bed a flowing gaseous environment of reactants around the catalyst is necessary. Here, we report the development of a new flowing reaction cell for simulating in-situ study of a catalyst surface under a reaction condition in gas of one reactant or during catalysis in a mixture of reactants of a catalytic reaction. The homemade reaction cell is installed in a high vacuum (HV) or ultrahigh vacuum (UHV) environment of a chamber. The flowing gas in the reaction cell is separated from the HV or UHV environment through well sealings at three interfaces between the reaction cell and X-ray window, sample door and aperture of front cone of an energy analyzer. Catalyst in the cell is heated through infrared laser beam introduced through a fiber optics interfaced with the reaction cell through a homemade feedthrough. The highly localized heating on the sample holder and Au-passivated internal surface of the reaction cell effectively minimizes any unwanted reactions potentially catalyzed by the reaction cell. The incorporated laser heating allows a fast heating and a high thermal stability of the sample at a high temperature. With this cell, a catalyst at 800 °C in a flowing gas can be tracked readily.

  9. Technology Transfer

    NASA Technical Reports Server (NTRS)

    Smith, Nanette R.

    1995-01-01

    The objective of this summer's work was to attempt to enhance Technology Application Group (TAG) ability to measure the outcomes of its efforts to transfer NASA technology. By reviewing existing literature, by explaining the economic principles involved in evaluating the economic impact of technology transfer, and by investigating the LaRC processes our William & Mary team has been able to lead this important discussion. In reviewing the existing literature, we identified many of the metrics that are currently being used in the area of technology transfer. Learning about the LaRC technology transfer processes and the metrics currently used to track the transfer process enabled us to compare other R&D facilities to LaRC. We discuss and diagram impacts of technology transfer in the short run and the long run. Significantly, it serves as the basis for analysis and provides guidance in thinking about what the measurement objectives ought to be. By focusing on the SBIR Program, valuable information regarding the strengths and weaknesses of this LaRC program are to be gained. A survey was developed to ask probing questions regarding SBIR contractors' experience with the program. Specifically we are interested in finding out whether the SBIR Program is accomplishing its mission, if the SBIR companies are providing the needed innovations specified by NASA and to what extent those innovations have led to commercial success. We also developed a survey to ask COTR's, who are NASA employees acting as technical advisors to the SBIR contractors, the same type of questions, evaluating the successes and problems with the SBIR Program as they see it. This survey was developed to be implemented interactively on computer. It is our hope that the statistical and econometric studies that can be done on the data collected from all of these sources will provide insight regarding the direction to take in developing systematic evaluations of programs like the SBIR Program so that they can

  10. Live cell isolation by laser microdissection with gravity transfer

    NASA Astrophysics Data System (ADS)

    Podgorny, Oleg V.

    2013-05-01

    Laser microdissection by pulsing ultraviolet laser allows the isolation and recultivation of live cells based on morphological features or/and fluorescent labelling from adherent cell cultures. Previous investigations described only the use of the laser microdissection and pressure catapulting (LMPC) for live cell isolation. But LMPC requires complex manipulations and some skill. Furthermore, single-cell cloning using laser microdissection has not yet been demonstrated. The first evidence of successful application of laser microdissection with gravity transfer (LMDGT) for capturing and recultivation of live cells is presented. A new strategy for LMDGT is presented because of the failure to reproduce the manufacturer's protocol. Using the new strategy, successful capturing and recultivation of circle-shaped samples from confluent monolayer of HeLa cells was demonstrated. It was found that LMDGT is easier than LMPC because it doesn't require personal participation of investigator in transferring of isolated samples to final culture dishes. Moreover, for the first time, the generation of clonal colonies from single live cells isolated by laser microdissection was demonstrated. Data obtained in this study confirm that LMDGT is a reliable and high-yield method allowing isolation and expansion of both cell clusters and single cells from adherent cell cultures.

  11. MStern Blotting-High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates.

    PubMed

    Berger, Sebastian T; Ahmed, Saima; Muntel, Jan; Cuevas Polo, Nerea; Bachur, Richard; Kentsis, Alex; Steen, Judith; Steen, Hanno

    2015-10-01

    We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. MStern Blotting–High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates*

    PubMed Central

    Berger, Sebastian T.; Ahmed, Saima; Muntel, Jan; Cuevas Polo, Nerea; Bachur, Richard; Kentsis, Alex; Steen, Judith; Steen, Hanno

    2015-01-01

    We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. PMID:26223766

  13. Estimating the circuit delay of FPGA with a transfer learning method

    NASA Astrophysics Data System (ADS)

    Cui, Xiuhai; Liu, Datong; Peng, Yu; Peng, Xiyuan

    2017-10-01

    With the increase of FPGA (Field Programmable Gate Array, FPGA) functionality, FPGA has become an on-chip system platform. Due to increase the complexity of FPGA, estimating the delay of FPGA is a very challenge work. To solve the problems, we propose a transfer learning estimation delay (TLED) method to simplify the delay estimation of different speed grade FPGA. In fact, the same style different speed grade FPGA comes from the same process and layout. The delay has some correlation among different speed grade FPGA. Therefore, one kind of speed grade FPGA is chosen as a basic training sample in this paper. Other training samples of different speed grade can get from the basic training samples through of transfer learning. At the same time, we also select a few target FPGA samples as training samples. A general predictive model is trained by these samples. Thus one kind of estimation model is used to estimate different speed grade FPGA circuit delay. The framework of TRED includes three phases: 1) Building a basic circuit delay library which includes multipliers, adders, shifters, and so on. These circuits are used to train and build the predictive model. 2) By contrasting experiments among different algorithms, the forest random algorithm is selected to train predictive model. 3) The target circuit delay is predicted by the predictive model. The Artix-7, Kintex-7, and Virtex-7 are selected to do experiments. Each of them includes -1, -2, -2l, and -3 different speed grade. The experiments show the delay estimation accuracy score is more than 92% with the TLED method. This result shows that the TLED method is a feasible delay assessment method, especially in the high-level synthesis stage of FPGA tool, which is an efficient and effective delay assessment method.

  14. Transfer of Learning. Symposium.

    ERIC Educational Resources Information Center

    2002

    This document contains three papers on transfer of training and human resources. "The Effect of Organizational Support, Management Support, and Peer Support on Transfer of Training" (Susan E. Cromwell, Judith A. Kolb) reports on a longitudinal study of work environment factors that affect transfer of training in a university supervisory…

  15. Transfer Learning with Convolutional Neural Networks for SAR Ship Recognition

    NASA Astrophysics Data System (ADS)

    Zhang, Di; Liu, Jia; Heng, Wang; Ren, Kaijun; Song, Junqiang

    2018-03-01

    Ship recognition is the backbone of marine surveillance systems. Recent deep learning methods, e.g. Convolutional Neural Networks (CNNs), have shown high performance for optical images. Learning CNNs, however, requires a number of annotated samples to estimate numerous model parameters, which prevents its application to Synthetic Aperture Radar (SAR) images due to the limited annotated training samples. Transfer learning has been a promising technique for applications with limited data. To this end, a novel SAR ship recognition method based on CNNs with transfer learning has been developed. In this work, we firstly start with a CNNs model that has been trained in advance on Moving and Stationary Target Acquisition and Recognition (MSTAR) database. Next, based on the knowledge gained from this image recognition task, we fine-tune the CNNs on a new task to recognize three types of ships in the OpenSARShip database. The experimental results show that our proposed approach can obviously increase the recognition rate comparing with the result of merely applying CNNs. In addition, compared to existing methods, the proposed method proves to be very competitive and can learn discriminative features directly from training data instead of requiring pre-specification or pre-selection manually.

  16. Cargo Transfer operations

    NASA Image and Video Library

    2014-08-21

    ISS040-E-103985 (21 Aug. 2014) --- NASA astronaut Steve Swanson, Expedition 40 commander, is pictured during cargo transfer operations in the "Georges Lemaitre" Automated Transfer Vehicle-5 (ATV-5) currently docked with the International Space Station.

  17. Results of Hg speciation testing on tanks 30, 32, and 37 depth samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.

    2015-11-30

    The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The twelfth shipment of samples was designated to include 3H evaporator system Tank 30, 32, and 37 depth samples. The Tank 30 depth sample (HTF-30-15-70) was taken at 190 inches from the tank bottom and the Tank 32 depth sample (HTF-32-15-68) was taken at 89 inches from the tank bottom and both were shipped to SRNL on June 29, 2015 in an 80 mLmore » stainless steel dip bottles. The Tank 37 surface sample (HTF-37-15-94) was taken around 253.4 inches from the tank bottom and shipped to SRNL on July 21, 2015 in an 80 mL stainless steel dip bottle. All samples were placed in the SRNL Shielded Cells and left unopened until intermediate dilutions were made on July 24, 2015 using 1.00 mL of sample diluted to 100.00 mL with deionized H 2O. A 30 mL Teflon® bottle was rinsed twice with the diluted tank sample and then filled leaving as little headspace as possible. It was immediately removed from the Shielded Cells and transferred to refrigerated storage where it remained at 4 °C until final dilutions were made on October 20. A second portion of the cells diluted tank sample was poured into a shielded polyethylene bottle and transferred to Analytical Development for radiochemical analysis data needed for Hazardous Material Transportation calculations.« less

  18. Surface friction of rock in terrestrial and simulated lunar environments

    NASA Technical Reports Server (NTRS)

    Roepke, W. W.; Peng, S. S.

    1975-01-01

    The conventional probe-on-the rotating-disk concept was used to determine the surface friction in mineral probe/specimen interfaces. Nine rocks or minerals and two stainless steels were tested in both new (NT) and same track (ST) tests under three different pressure environments-atmospheric, UHV, and dry nitrogen. Each environment was further subdivided into two testing conditions, that is, ambient and elevated (135 C) temperatures. In NT tests, friction was the lowest in an atmospheric pressure condition for all rock types and increased to the largest in UHV ambient condition except for pyroxene and stainless steel. Friction values measured in dry nitrogen ambient condition lie between the two extremes. Heating tends to increase friction in atmospheric and dry nitrogen environment but decreases in UHV environment with the exception of stainless steel, basalt, and pyroxene. In ST tests, friction was the lowest in the first run and increased in subsequent runs except for stainless steel where the reverse was true. The increases leveled off after a few runs ranging from the second to the seventh depending on rock types.

  19. Ultrahigh-viscosity hydroxypropylmethylcellulose blunts postprandial glucose after a breakfast meal in women.

    PubMed

    Dow, Shireen; Pritchett, Kelly L; Hawk, Susan; Herrington, Stefanie J; Gee, David L

    2012-04-01

    To determine the effects of two water-soluble dietary fibers, ultrahigh-viscosity hydroxypropylmethylcellulose (UHV-HPMC, nonfermentable) and psyllium fiber (fermentable), on postprandial glucose and second meal effects. In a single-blind crossover design, 12 healthy adult subjects were given standardized, premeasured breakfast and lunch meals with either 4 g of the fiber supplements or a placebo. Blood glucose was measured with a continuous blood glucose monitoring system (DexCom Seven Plus, San Diego, CA). Subjects consuming UHV-HPMC had significantly (p < 0.05) lower blood glucose area under the curve (AUC) 2 hours after breakfast than those receiving a placebo. Subjects consuming psyllium also tended to have lower glucose levels than the placebo group. Peak glucose concentration following breakfast was significantly (p < 0.01) less with UHV-HPMC when compared with the placebo. No significant differences in AUC or peak glucose concentration between treatments following the second meal (lunch) were detected, suggesting no residual effect from the fiber supplements. Supplementation with viscous water-soluble fibers may be an effective means of reducing the glycemic response of a meal in healthy adults.

  20. Analyzing cost-effectiveness of ulnar and median nerve transfers to regain forearm flexion.

    PubMed

    Wali, Arvin R; Park, Charlie C; Brown, Justin M; Mandeville, Ross

    2017-03-01

    OBJECTIVE Peripheral nerve transfers to regain elbow flexion via the ulnar nerve (Oberlin nerve transfer) and median nerves are surgical options that benefit patients. Prior studies have assessed the comparative effectiveness of ulnar and median nerve transfers for upper trunk brachial plexus injury, yet no study has examined the cost-effectiveness of this surgery to improve quality-adjusted life years (QALYs). The authors present a cost-effectiveness model of the Oberlin nerve transfer and median nerve transfer to restore elbow flexion in the adult population with upper brachial plexus injury. METHODS Using a Markov model, the authors simulated ulnar and median nerve transfers and conservative measures in terms of neurological recovery and improvements in quality of life (QOL) for patients with upper brachial plexus injury. Transition probabilities were collected from previous studies that assessed the surgical efficacy of ulnar and median nerve transfers, complication rates associated with comparable surgical interventions, and the natural history of conservative measures. Incremental cost-effectiveness ratios (ICERs), defined as cost in dollars per QALY, were calculated. Incremental cost-effectiveness ratios less than $50,000/QALY were considered cost-effective. One-way and 2-way sensitivity analyses were used to assess parameter uncertainty. Probabilistic sampling was used to assess ranges of outcomes across 100,000 trials. RESULTS The authors' base-case model demonstrated that ulnar and median nerve transfers, with an estimated cost of $5066.19, improved effectiveness by 0.79 QALY over a lifetime compared with conservative management. Without modeling the indirect cost due to loss of income over lifetime associated with elbow function loss, surgical treatment had an ICER of $6453.41/QALY gained. Factoring in the loss of income as indirect cost, surgical treatment had an ICER of -$96,755.42/QALY gained, demonstrating an overall lifetime cost savings due to