Rogers, Andy; Chapple, Claire-Louise; Murray, Maria; Platton, David; Saunderson, John
2017-11-01
There has been concern expressed by the UK regulator, the Health & Safety Executive, regarding the management of occupation dose for healthcare radiation workers who work across multiple organizations. In response to this concern, the British Institute of Radiology led a working group of relevant professional bodies to develop guidance in this area. The guidance addresses issues of general system management that would apply to all personal dosimetry systems, regardless of whether or not the workers within that system work across organizational boundaries, along with exploring efficient strategies to comply with legislation where those workers do indeed work across organizational boundaries. For those specific instances, the guidance discusses both system requirements to enable organizations to co-operate (Ionising Radiation Regulations 1999 Regulation 15), as well as specific instances of staff exposure. This is broken down into three categories-low, medium and high risk. A suggested approach to each is given to guide employers and their radiation advisers in adopting sensible strategies for the monitoring of their staff and the subsequent sharing of dosimetry data to ensure overall compliance with both dose limits and optimization requirements.
Rogers, Andy
2017-11-01
The requirement for organizations to co-operate regarding doses to staff who work across organizational boundaries is well established. However, in the field of personal dosimetry there is little guidance as to how to actually achieve legal compliance. Following improvement action in the UK by the regulator, The Health & Safety Executive, a guidance document was developed by the leading professional bodies in this area. This guidance was also commented on by the Health & Safety Executive Specialist Inspectorate (Radiation) enabling the published guidance to represent a compliant standard. This commentary describes the guidance and discusses the issues involved with developing systems for compliance in this area.
Palmer, Antony L; Pearson, Michael; Whittard, Paul; McHugh, Katie E; Eaton, David J
2016-12-01
To assess the status and practice of kilovoltage (kV) radiotherapy in the UK. 96% of the radiotherapy centres in the UK responded to a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical treatment sites, quality control (QC) testing and radiation dosimetry processes were undertaken. 73% of UK centres have at least one kV treatment unit, with 58 units installed across the UK. Although 35% of units are over 10 years old, 39% units have been installed in the last 5 years. Approximately 6000 patients are treated with kV units in the UK each year, the most common site (44%) being basal cell carcinoma. A benchmark of QC practice in the UK is presented, against which individual centres can compare their procedures, frequency of testing and acceptable tolerance values. We propose the use of internal "notification" and "suspension" levels for analysis. All surveyed centres were using recommended Codes of Practice for kV dosimetry in the UK; approximately the same number using in-air and in-water methodologies for medium energy, with two-thirds of all centres citing "clinical relevance" as the reason for choice of code. 64% of centres had hosted an external dosimetry audit within the last 3 years, with only one centre never being independently audited. The majority of centres use locally measured applicator factors and published backscatter factors for treatments. Monitor unit calculations are performed using software in only 36% of centres. A comprehensive review of current kV practice in the UK is presented. Advances in knowledge: Data and discussion on contemporary kV radiotherapy in the UK, with a particular focus on physics aspects.
Pearson, Michael; Whittard, Paul; McHugh, Katie E; Eaton, David J
2016-01-01
Objective: To assess the status and practice of kilovoltage (kV) radiotherapy in the UK. Methods: 96% of the radiotherapy centres in the UK responded to a comprehensive survey. An analysis of the installed equipment base, patient numbers, clinical treatment sites, quality control (QC) testing and radiation dosimetry processes were undertaken. Results: 73% of UK centres have at least one kV treatment unit, with 58 units installed across the UK. Although 35% of units are over 10 years old, 39% units have been installed in the last 5 years. Approximately 6000 patients are treated with kV units in the UK each year, the most common site (44%) being basal cell carcinoma. A benchmark of QC practice in the UK is presented, against which individual centres can compare their procedures, frequency of testing and acceptable tolerance values. We propose the use of internal “notification” and “suspension” levels for analysis. All surveyed centres were using recommended Codes of Practice for kV dosimetry in the UK; approximately the same number using in-air and in-water methodologies for medium energy, with two-thirds of all centres citing “clinical relevance” as the reason for choice of code. 64% of centres had hosted an external dosimetry audit within the last 3 years, with only one centre never being independently audited. The majority of centres use locally measured applicator factors and published backscatter factors for treatments. Monitor unit calculations are performed using software in only 36% of centres. Conclusion: A comprehensive review of current kV practice in the UK is presented. Advances in knowledge: Data and discussion on contemporary kV radiotherapy in the UK, with a particular focus on physics aspects. PMID:27730839
In vivo dosimetry in UK external beam radiotherapy: current and future usage.
MacDougall, Niall D; Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-04-01
Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation.
In vivo dosimetry in UK external beam radiotherapy: current and future usage
Graveling, Michael; Hansen, Vibeke N; Brownsword, Kevin; Morgan, Andrew
2017-01-01
Objective: Towards Safer Radiotherapy recommended that radiotherapy (RT) centres should have protocols in place for in vivo dosimetry (IVD) monitoring at the beginning of patient treatment courses (Donaldson S. Towards safer radiotherapy. R Coll Radiol 2008). This report determines IVD implementation in the UK in 2014, the methods used and makes recommendations on future use. Methods: Evidence from peer-reviewed journals was used in conjunction with the first survey of UK RT centre IVD practice since the publication of Towards Safer Radiotherapy. In March 2014, profession-specific questionnaires were sent to radiographer, clinical oncologist and physics staff groups in each of the 66 UK RT centres. Results: Response rates from each group were 74%, 45% and 74%, respectively. 73% of RT centres indicated that they performed IVD. Diodes are the most popular IVD device. Thermoluminescent dosimeter (TLD) is still in use in a number of centres but not as a sole modality, being used in conjunction with diodes and/or electronic portal imaging device (EPID). The use of EPID dosimetry is increasing and is considered of most potential value for both geometric and dosimetric verification. Conclusion: Owing to technological advances, such as electronic data transfer, independent monitor unit checking and daily image-guided radiotherapy, the overall risk of adverse treatment events in RT has been substantially reduced. However, the use of IVD may prevent a serious radiation incident. Point dose IVD is not considered suited to the requirements of verifying advanced RT techniques, leaving EPID dosimetry as the current modality likely to be developed as a future standard. Advances in knowledge: An updated perspective on UK IVD use and provision of professional guidelines for future implementation. PMID:28205452
Clark, Catharine H; Aird, Edwin G A; Bolton, Steve; Miles, Elizabeth A; Nisbet, Andrew; Snaith, Julia A D; Thomas, Russell A S; Venables, Karen; Thwaites, David I
2015-01-01
Dosimetry audit plays an important role in the development and safety of radiotherapy. National and large scale audits are able to set, maintain and improve standards, as well as having the potential to identify issues which may cause harm to patients. They can support implementation of complex techniques and can facilitate awareness and understanding of any issues which may exist by benchmarking centres with similar equipment. This review examines the development of dosimetry audit in the UK over the past 30 years, including the involvement of the UK in international audits. A summary of audit results is given, with an overview of methodologies employed and lessons learnt. Recent and forthcoming more complex audits are considered, with a focus on future needs including the arrival of proton therapy in the UK and other advanced techniques such as four-dimensional radiotherapy delivery and verification, stereotactic radiotherapy and MR linear accelerators. The work of the main quality assurance and auditing bodies is discussed, including how they are working together to streamline audit and to ensure that all radiotherapy centres are involved. Undertaking regular external audit motivates centres to modernize and develop techniques and provides assurance, not only that radiotherapy is planned and delivered accurately but also that the patient dose delivered is as prescribed.
Aird, Edwin GA; Bolton, Steve; Miles, Elizabeth A; Nisbet, Andrew; Snaith, Julia AD; Thomas, Russell AS; Venables, Karen; Thwaites, David I
2015-01-01
Dosimetry audit plays an important role in the development and safety of radiotherapy. National and large scale audits are able to set, maintain and improve standards, as well as having the potential to identify issues which may cause harm to patients. They can support implementation of complex techniques and can facilitate awareness and understanding of any issues which may exist by benchmarking centres with similar equipment. This review examines the development of dosimetry audit in the UK over the past 30 years, including the involvement of the UK in international audits. A summary of audit results is given, with an overview of methodologies employed and lessons learnt. Recent and forthcoming more complex audits are considered, with a focus on future needs including the arrival of proton therapy in the UK and other advanced techniques such as four-dimensional radiotherapy delivery and verification, stereotactic radiotherapy and MR linear accelerators. The work of the main quality assurance and auditing bodies is discussed, including how they are working together to streamline audit and to ensure that all radiotherapy centres are involved. Undertaking regular external audit motivates centres to modernize and develop techniques and provides assurance, not only that radiotherapy is planned and delivered accurately but also that the patient dose delivered is as prescribed. PMID:26329469
1981-09-01
setting and application of RFR safety standards, assessment of RFR levels in the military workplaces, RFR instrumentation and dosimetry , the medical...RADIOFREQUENCY BURN HAZARDS IN THE MF/HF BAND ................ ... 76 S. J. Rogers (U.K.) 3. RADIOFREQUENCY RADIATION INSTRUMENTATION AND DOSIMETRY ...97 B. Audone, L. Bolla, and G. Gerbi (Italy) RADIOFREQUENCY RADIATION DOSIMETRY : A REVIEW OF THEORETICAL METHODS AND EXPERIMENTAL RESULTS
NASA Astrophysics Data System (ADS)
Monthonwattana, S.; Esor, J.; Rungseesumran, T.; Intang, A.
2017-06-01
Optically Stimulated Luminescence (OSL) is the current technique of personal dosimetry changed by Nuclear Technology Service Center instead of Thermoluminescence dosimetry (TLD) because OSL has more advantages, such as repeat reading and elimination of heating process. In this study, OSL was used to test the gamma response characterizations. Detailed OSL investigation on personal dosimetry was carried out in the dose range of 0.2 - 3.0 mSv. The batch homogeneity was 7.66%. R2 value of the linear regression was 0.9997. The difference ratio of angular dependence at ± 60° was 8.7%. Fading of the reading was about 3%.
Hosseini Pooya, SM; Orouji, T
2014-01-01
Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. Method: These sources are included; inhomogeneity of TLDs sensitivity, variability of TLD readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. Some parameters which influence on the above sources of uncertainty are studied for Harshaw TLD-100 cards dosimeters as well as the hot gas Harshaw 6600 TLD reader system. Results: The individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. The total uncertainty was calculated 17.5% with 95% confidence level. Conclusion: The TLD-100 personal dosimeters as well as the Harshaw TLD-100 reader 6600 system show the total uncertainty value which is less than that of admissible value of 42% for personal dosimetry services. PMID:25505769
The Royal College of Radiologists' audit of prostate brachytherapy in the year 2012.
Stewart, A J; Drinkwater, K J; Laing, R W; Nobes, J P; Locke, I
2015-06-01
This audit provides a comprehensive overview of UK prostate brachytherapy practice in the year 2012, measured against existing standards, immediately before the introduction of new Royal College of Radiologists (RCR) guidelines. This audit allows comparison with European and North American brachytherapy practice and for the impact of the RCR 2012 guidelines to be assessed in the future. A web-based data collection tool was developed by the RCR Clinical Audit Committee and sent to audit leads at all cancer centres in the UK. Standards were developed based on available guidelines in use at the start of 2012 covering case mix and dosimetry. Further questions were included to reflect areas of anticipated change with the implementation of the 2012 guidelines. Audit findings were compared with similar audits of practice in Europe, the USA and Latin America. Forty-nine of 59 cancer centres submitted data. Twenty-nine centres reported carrying out prostate brachytherapy; of these, 25 (86%) provided data regarding the number of implants, staffing, dosimetry, medication and anaesthesia and follow-up. Audit standards achieved excellent compliance in most areas, although were low in post-implant dosimetry and in post-implant scanning at 30 days. This audit provides a comprehensive picture of prostate brachytherapy in the UK in 2012. Patterns of care of prostate brachytherapy are similar to practice in the USA and Europe. The number of prostate brachytherapy implants carried out in the UK has grown significantly since a previous RCR audit in 2005 and it is important that centres maintain minimum numbers of cases to ensure that experience can be maintained and compliance to guidelines achieved. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Zeyrek, C T; Gündüz, H
2012-09-01
This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.
Thermoluminescent dosimetry in veterinary diagnostic radiology.
Hernández-Ruiz, L; Jimenez-Flores, Y; Rivera-Montalvo, T; Arias-Cisneros, L; Méndez-Aguilar, R E; Uribe-Izquierdo, P
2012-12-01
This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. Copyright © 2012 Elsevier Ltd. All rights reserved.
Lee, Min Sun; Kim, Joong Hyun; Paeng, Jin Chul; Kang, Keon Wook; Jeong, Jae Min; Lee, Dong Soo; Lee, Jae Sung
2017-12-14
Personalized dosimetry with high accuracy is becoming more important because of the growing interests in personalized medicine and targeted radionuclide therapy. Voxel-based dosimetry using dose point kernel or voxel S-value (VSV) convolution is available. However, these approaches do not consider medium heterogeneity. Here, we propose a new method for whole-body voxel-based personalized dosimetry for heterogeneous media with non-uniform activity distributions, which is referred to as the multiple VSV approach. Methods: The multiple numbers (N) of VSVs for media with different densities covering the whole-body density ranges were used instead of using only a single VSV for water. The VSVs were pre-calculated using GATE Monte Carlo simulation; those were convoluted with the time-integrated activity to generate density-specific dose maps. Computed tomography-based segmentation was conducted to generate binary maps for each density region. The final dose map was acquired by the summation of N segmented density-specific dose maps. We tested several sets of VSVs with different densities: N = 1 (single water VSV), 4, 6, 8, 10, and 20. To validate the proposed method, phantom and patient studies were conducted and compared with direct Monte Carlo, which was considered the ground truth. Finally, patient dosimetry (10 subjects) was conducted using the multiple VSV approach and compared with the single VSV and organ-based dosimetry approaches. Errors at the voxel- and organ-levels were reported for eight organs. Results: In the phantom and patient studies, the multiple VSV approach showed significant improvements regarding voxel-level errors, especially for the lung and bone regions. As N increased, voxel-level errors decreased, although some overestimations were observed at lung boundaries. In the case of multiple VSVs ( N = 8), we achieved voxel-level errors of 2.06%. In the dosimetry study, our proposed method showed much improved results compared to the single VSV and organ-based dosimetry. Errors at the organ-level were -6.71%, 2.17%, and 227.46% for the single VSV, multiple VSV, and organ-based dosimetry, respectively. Conclusion: The multiple VSV approach for heterogeneous media with non-uniform activity distributions offers fast personalized dosimetry at whole-body level, yielding results comparable to those of the direct Monte Carlo approach. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
2003-03-01
facility and Mr. Joseph Talnagi of the Ohio State Research Reactor facility for their personal guidance and insight into reactor dosimetry and neutron...62 Test C1: Dosimetry ..................................................................................................... 63 Special...66 Annex A-3. Preliminary Dosimetry Calculations
Internal dosimetry technical basis manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-20
The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophicalmore » discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.« less
NASA Astrophysics Data System (ADS)
Dance, D. R.; Young, K. C.
2014-05-01
The UK, European and IAEA protocols for breast dosimetry in mammography use tabulations of conversion factors, which relate measurements of incident air kerma to the mean glandular dose to the breast. To supplement the existing tabulations, a Monte Carlo computer program has been used to calculate conversion factors for the high-energy spectra used for contrast enhanced digital mammography. The calculations were made for the x-ray spectra from a tungsten target (tube voltage range 40-50 kV) filtered by 0.28, 0.30 and 0.32 mm of copper, and from molybdenum and rhodium targets (tube voltage range 40-49 kV), each filtered by 0.30 mm of copper. The g-factors for all of these spectra were plotted for each breast thickness as a function of half value layer (HVL) and were found to lie on smooth curves within 0.3%. These reflect the fact that the characteristic x-rays present in the spectra from molybdenum and rhodium are heavily filtered and all the spectra are essentially Bremsstrahlung. As a consequence, the s-factor previously used in the dosimetry protocols to adjust for different target/filter combinations can be taken as unity for all of the spectra considered. Tables of g-factors and c-factors are provided for breast thicknesses in the range 20-110 mm and HVLs in the range 2.4-3.6 mm of aluminium. The tables of c-factors are given for breast glandularities in the range 0.1%-100% and for typical glandularities for women in the age bands 40-49 and 50-64 attending the UK national breast screening programme.
CURRENT STATUS OF INDIVIDUAL DOSIMETRIC MONITORING IN UKRAINE.
Chumak, V; Deniachenko, N; Makarovska, O; Mihailescu, L-C; Prykhodko, A; Voloskyi, V; Vanhavere, F
2016-09-01
About 50 000 workers are being occupationally exposed to radiation in Ukraine. Individual dosimetric monitoring (IDM) is provided by 77 dosimetry services and laboratories of very different scale with a number of monitored workers ranging from several persons to ∼9000. In the present work, the current status of personal dosimetry in Ukraine was studied. The First National Intercomparison (FNI) of the IDM labs was accompanied by a survey of the laboratory operation in terms of coverage, types of dosimetry provided, instrumentation and methodologies used, metrological support, data recording, etc. Totally, 34 laboratories responded to the FNI call, and 18 services with 19 different personal dosimetry systems took part in the intercomparison exercise providing 24 dosimeters each for blind irradiation to photons of 6 different qualities (ISO N-series X-rays, S-Cs and S-Co sources) in a dose range of 5-60 mSv. Performance of the dosimetry labs was evaluated according to ISO 14146 criteria of matching trumpet curves with H0 = 0.2 mSv. The test revealed that 8 of the 19 systems meet ISO 14146 criteria in full, 5 other labs show marginal performance and 6 laboratories demonstrated catastrophic quality of dosimetric results. Altogether, 18 participating labs provide dosimetric monitoring to 37 477 workers (about three-fourths of all occupationally exposed workers), usually on monthly (nuclear industry) or quarterly (rest of applications) basis. Of this number, 20 664 persons (55 %) receive completely adequate individual monitoring, and the number of personnel receiving IDM of inadequate quality counts 3054 persons. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
ESR dosimetry for atomic bomb survivors and radiologic technologists
NASA Astrophysics Data System (ADS)
Tatsumi-Miyajima, Junko
1987-06-01
An individual absorbed dose for atomic bomb (A-bomb) survivors and radiologic technologists has been estimated using a new personal dosimetry. This dosimetry is based on the electron spin resonance (ESR) spectroscopy of the CO 33- radicals, which are produced in their teeth by radiation. Measurements were carried out to study the characteristics of the dosimetry; the ESR signals of the CO 33- radicals were stable and increased linearly with the radiation dose. In the evaluation of the absorbed dose, the ESR signals were considered to be a function of photon energy. The absorbed doses in ten cases of A-bomb victims and eight cases of radiologic technologists were determined. For A-bomb survivors, the adsorbed doses, which were estimated using the ESR dosimetry, were consistent with the ones obtained using the calculations of the tissue dose in air of A-bomb, and also with the ones obtained using the chromosome measurements. For radiologic technologists, the absorbed doses, which were estimated using the ESR dosimetry, agreed with the ones calculated using the information on the occupational history and conditions. The advantages of this method are that the absorbed dose can be directly estimated by measuring the ESR signals obtained from the teeth of persons, who are exposed to radiation. Therefore, the ESR dosimetry is useful to estimate the accidental exposure and the long term cumulative dose.
Darling, A L; Hart, K H; Macdonald, H M; Horton, K; Kang'ombe, A R; Berry, J L; Lanham-New, S A
2013-02-01
This is the first 1-year longitudinal study which assesses vitamin D deficiency in young UK-dwelling South Asian women. The findings are that vitamin D deficiency is extremely common in this group of women and that it persists all year around, representing a significant public health concern. There is a lack of longitudinal data assessing seasonal variation in vitamin D status in young South Asian women living in northern latitudes. Studies of postmenopausal South Asian women suggest a lack of seasonal change in 25-hydroxy vitamin D [25(OH)D], although it is unclear whether this is prevalent among premenopausal South Asians. We aimed to evaluate, longitudinally, seasonal changes in 25(OH)D and prevalence of vitamin D deficiency in young UK-dwelling South Asian women as compared with Caucasians. We also aimed to establish the relative contributions of dietary vitamin D and sun exposure in explaining serum 25(OH)D. This is a 1-year prospective cohort study assessing South Asian (n = 35) and Caucasian (n = 105) premenopausal women living in Surrey, UK (51° N), aged 20-55 years. The main outcome measured was serum 25(OH)D concentration. Secondary outcomes were serum parathyroid hormone, self-reported dietary vitamin D intake and UVB exposure by personal dosimetry. Serum 25(OH)D <25 nmol/L was highly prevalent in South Asians in the winter (81 %) and autumn (79.2 %). Deficient status (below 50 nmol/L) was common in Caucasian women. Multi-level modelling suggested that, in comparison to sun exposure (1.59, 95 %CI = 0.83-2.35), dietary intake of vitamin D had no impact on 25(OH)D levels (-0.08, 95 %CI = -1.39 to 1.23). Year-round vitamin D deficiency was extremely common in South Asian women. These findings pose great health threats regarding the adverse effects of vitamin D deficiency in pregnancy and warrant urgent vitamin D public health policy and action.
Romero, A M; Rodríguez, R; López, J L; Martín, R; Benavente, J F
2016-09-01
In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
2013-11-06
safety regulations to include a review of worker radiation dosimetry and radiation safety training records was completed. c. Survey Personnel...that is based upon T.O. 33B-1-1, 10 CFR 20, and AFMAN 48-125, Personnel Ionizing Radiation Dosimetry . (1) Verify unshielded/shielded NDI safety...rope barriers marked with appropriate signage as required by T.O. 33B-1-1. (4) Verify x-ray shot and personal radiation dosimetry logs were properly
Analysis of regional radiotherapy dosimetry audit data and recommendations for future audits
Palmer, A; Mzenda, B; Kearton, J; Wills, R
2011-01-01
Objectives Regional interdepartmental dosimetry audits within the UK provide basic assurances of the dosimetric accuracy of radiotherapy treatments. Methods This work reviews several years of audit results from the South East Central audit group including megavoltage (MV) and kilovoltage (kV) photons, electrons and iodine-125 seeds. Results Apart from some minor systematic errors that were resolved, the results of all audits have been within protocol tolerances, confirming the long-term stability and agreement of basic radiation dosimetric parameters between centres in the audit region. There is some evidence of improvement in radiation dosimetry with the adoption of newer codes of practice. Conclusion The value of current audit methods and the limitations of peer-to-peer auditing is discussed, particularly the influence of the audit schedule on the results obtained, where no “gold standard” exists. Recommendations are made for future audits, including an essential requirement to maintain the monitoring of basic fundamental dosimetry, such as MV photon and electron output, but audits must also be developed to include new treatment technologies such as image-guided radiotherapy and address the most common sources of error in radiotherapy. PMID:21159805
2005 Annual Health Physics Report for HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2006-04-21
During the 2005 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Program (HEU-TP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2005, there were 161 person-trips that required dose monitoring of the U.S. monitors. Of the 161 person-trips, 149 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. Additionally, there were 11 monitoring visits by TMO monitors to facilities other than UEIE and 3 to UEIE itself. There were two monitoring visits (source changes)more » that were back to back with 16 monitors. Each of these concurring visits were treated as single person-trips for dosimetry purposes. Counted individually, there were 191 individual person-visits in 2005. The LLNL Safety Laboratories Division provided the dosimetry services for the HEU-TP monitors.« less
Misson-Yates, S; Gonzalez, R; McGovern, M; Greener, A
2015-05-01
This article describes the external audit measurements conducted in two UK centres implementing total skin electron beam therapy (TSEBT) and the results obtained. Measurements of output, energy, beam flatness and symmetry at a standard distance (95 or 100 cm SSD) were performed using a parallel plate chamber in solid water. Similarly, output and energy measurements were also performed at the treatment plane for single and dual fields. Clinical simulations were carried out using thermoluminescent dosemeters (TLDs) and Gafchromic® film (International Specialty Products, Wayne, NJ) on an anthropomorphic phantom. Extended distance measurements confirmed that local values for the beam dosimetry at Centres A and B were within 2% for outputs and 1-mm agreement of the expected depth at which the dose is 50% of the maximum for the depth-dose curve in water (R50,D) value. Clinical simulation using TLDs) showed an agreement of -1.6% and -6.7% compared with the expected mean trunk dose for each centre, respectively, and a variation within 10% (±1 standard deviation) across the trunk. The film results confirmed that the delivery of the treatment technique at each audited centre complies with the European Organisation for Research and Treatment of Cancer recommendations. This audit methodology has proven to be a successful way to confirm the agreement of dosimetric parameters for TSEBT treatments at both audited centres and could serve as the basis for an audit template to be used by other audit groups. TSEBT audits are not established in the UK owing to a limited number of centres carrying out the treatment technique. This article describes the audits performed at two UK centres prior to their clinical implementation.
Gonzalez, R; McGovern, M; Greener, A
2015-01-01
Objective: This article describes the external audit measurements conducted in two UK centres implementing total skin electron beam therapy (TSEBT) and the results obtained. Methods: Measurements of output, energy, beam flatness and symmetry at a standard distance (95 or 100 cm SSD) were performed using a parallel plate chamber in solid water. Similarly, output and energy measurements were also performed at the treatment plane for single and dual fields. Clinical simulations were carried out using thermoluminescent dosemeters (TLDs) and Gafchromic® film (International Specialty Products, Wayne, NJ) on an anthropomorphic phantom. Results: Extended distance measurements confirmed that local values for the beam dosimetry at Centres A and B were within 2% for outputs and 1-mm agreement of the expected depth at which the dose is 50% of the maximum for the depth–dose curve in water (R50,D) value. Clinical simulation using TLDs) showed an agreement of −1.6% and −6.7% compared with the expected mean trunk dose for each centre, respectively, and a variation within 10% (±1 standard deviation) across the trunk. The film results confirmed that the delivery of the treatment technique at each audited centre complies with the European Organisation for Research and Treatment of Cancer recommendations. Conclusion: This audit methodology has proven to be a successful way to confirm the agreement of dosimetric parameters for TSEBT treatments at both audited centres and could serve as the basis for an audit template to be used by other audit groups. Advances in knowledge: TSEBT audits are not established in the UK owing to a limited number of centres carrying out the treatment technique. This article describes the audits performed at two UK centres prior to their clinical implementation. PMID:25761213
NASA Astrophysics Data System (ADS)
Morgan, A. M.; Aird, E. G. A.; Aukett, R. J.; Duane, S.; Jenkins, N. H.; Mayles, W. P. M.; Moretti, C.; Thwaites, D. I.
2000-09-01
United Kingdom dosimetry codes of practice have traditionally specified one electrometer for use as a secondary standard, namely the Nuclear Enterprises (NE) 2560 NPL secondary standard therapy level exposure meter. The NE2560 will become obsolete in the foreseeable future. This report provides guidelines to assist physicists following the United Kingdom dosimetry codes of practice in the selection of an electrometer to replace the NE2560 when necessary. Using an internationally accepted standard (BS EN 60731:1997) as a basis, estimated error analyses demonstrate that the uncertainty (one standard deviation) in a charge measurement associated with the NE2560 alone is approximately 0.3% under specified conditions. Following a review of manufacturers' literature, it is considered that modern electrometers should be capable of equalling this performance. Additional constructural and operational requirements not specified in the international standard but considered essential in a modern electrometer to be used as a secondary standard are presented.
Lee, S Y; Kim, B H; Lee, K J
2001-06-01
Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on alpha-Al2O3:C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using alpha-Al2O3:C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of X- and gamma-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of alpha-Al2O3:C for arbitrarily mixed photon fields which range from 20 to 662 keV. c2001 Elsevier Science Ltd. All rights reserved.
Effectiveness evaluation of existing noise controls in a deep shaft underground mine.
Lutz, Eric A; Reed, Rustin J; Turner, Dylan; Littau, Sally R; Lee, Vivien; Hu, Chengcheng
2015-01-01
Noise exposures and hearing loss in the mining industry continue to be a major problem, despite advances in noise control technologies. This study evaluated the effectiveness of engineering, administrative, and personal noise controls using both traditional and in-ear dosimetry by job task, work shift, and five types of earplug. The noise exposures of 22 miners performing deep shaft-sinking tasks were evaluated during 56 rotating shifts in an underground mine. Miners were earplug-insertion trained, earplug fit-tested, and monitored utilizing traditional and in-ear dosimetry. The mean TWA8 noise exposure via traditional dosimetry was 90.1 ± 8.2 dBA, while the mean in-ear TWA8 was 79.6 ± 13.8 dBA. The latter was significantly lower (p < 0.05) than the Mine Safety and Health Administration (MSHA) personal exposure limit (PEL) of 90 dBA. Dosimetry mean TWA8 noise exposures for bench blowing (103.5 ± 0.9 dBA), jumbo drill operation (103.0 ± 0.8 dBA), and mucking tasks (99.6 ± 4.7 dBA) were significantly higher (p < 0.05) than other tasks. For bench blowing, cable pulling, grinding, and jumbo drill operation tasks, the mean in-ear TWA8 was greater than 85 dBA. Those working swing shift had a significantly higher (p < 0.001) mean TWA8 noise exposure (95.4 ± 7.3 dBA) than those working day shift. For percent difference between traditional vs. in-ear dosimetry, there was no significant difference among types of earplug used. Reflective of occupational hearing loss rate trends across the mining industry, this study found that, despite existing engineering and administrative controls, noise exposure levels exceeded regulatory limits, while the addition of personal hearing protection limited excessive exposures.
Type Testing of Model 7200 Automatic TLD Reader.
Malek Mohammadi, M; Hosseini Pooya, S M
2017-04-20
The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
The ENEA neutron personal dosimetry service.
Morelli, B; Mariotti, F; Fantuzzi, E
2006-01-01
The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and (7)LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of H(p)(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and 'dummy customer' (blind test) for each issuing monitoring period) are presented and discussed.
Performance assessment of the BEBIG MultiSource® high dose rate brachytherapy treatment unit
NASA Astrophysics Data System (ADS)
Palmer, Antony; Mzenda, Bongile
2009-12-01
A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource® High Dose Rate (HDR) brachytherapy treatment unit with an 192Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high quality brachytherapy treatment delivery, taking the above factors into account.
Czech results at criticality dosimetry intercomparison 2002.
Frantisek, Spurný; Jaroslav, Trousil
2004-01-01
Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.
Stepanenko, Valeriy F; Hoshi, Masaharu; Bailiff, Ian K; Ivannikov, Alexander I; Toyoda, Shin; Yamamoto, Masayoshi; Simon, Steven L; Matsuo, Masatsugu; Kawano, Noriyuki; Zhumadilov, Zhaxybay; Sasaki, Masao S; Rosenson, Rafail I; Apsalikov, Kazbek N
2006-02-01
The paper is an analytical overview of the main results presented at the 3rd Dosimetry Workshop in Hiroshima(9-11 of March 2005), where different aspects of the dose reconstruction around the Semipalatinsk nuclear test site(SNTS) were discussed and summarized. The results of the international intercomparison of the retrospective luminescence dosimetry(RLD) method for Dolon' village(Kazakhstan) were presented at the Workshop and good concurrence between dose estimations by different laboratories from 6 countries (Japan, Russia, USA, Germany, Finland and UK) was pointed out. The accumulated dose values in brick for a common depth of 10mm depth obtained independently by all participating laboratories were in good agreement for all four brick samples from Dolon' village, Kazakhstan, with the average value of the local gamma dose due to fallout (near the sampling locations) being about 220 mGy(background dose has been subtracted).Furthermore, using a conversion factor of about 2 to obtain the free-in-air dose, a value of local dose approximately 440 mGy is obtained, which supports the results of external dose calculations for Dolon': recently published soil contamination data, archive information and new models were used for refining dose calculations and the external dose in air for Dolon village was estimated to be about 500 mGy. The results of electron spin resonance(ESR) dosimetry with tooth enamel have demonstrated the notable progress in application of ESR dosimetry to the problems of dose reconstruction around the Semipalatinsk nuclear test site. At the present moment, dose estimates by the ESR method have become more consistent with calculated values and with retrospective luminescence dosimetry data, but differences between ESR dose estimates and RLD/calculation data were noted. For example mean ESR dose for eligible tooth samples from Dolon' village was estimated to be about 140 mGy(above background dose), which is less than dose values obtained by RLD and calculations. A possible explanation of the differences between ESR and RLD/calculations doses is the following: for interpretation of ESR data the "shielding and behaviour" factors for investigated persons should be taken into account. The "upper level" of the combination of "shielding and behaviour" factors of dose reduction for inhabitants of Dolon' village of about 0.28 was obtained by comparing the individual ESR tooth enamel dose estimates with the calculated mean dose for this settlement. The biological dosimetry data related to the settlements near SNTS were presented at the Workshop. A higher incidence of unstable chromosome aberrations, micronucleus in lymphocytes, nuclear abnormalities of thyroid follicular cells, T-cell receptor mutations in peripheral blood were found for exposed areas (Dolon', Sarjal) in comparison with unexposed ones(Kokpekty). The significant greater frequency of stable translocations (results of analyses of chromosome aberrations in lymphocytes by the FISH technique) was demonstrated for Dolon' village in comparison with Chekoman(unexposed village). The elevated level of stable translocations in Dolon' corresponds to a dose of about 180 mSv, which is close to the results of ESR dosimetry for this village. The importance of investigating specific morphological types of thyroid nodules for thyroid dosimetry studies was pointed out. In general the 3rd Dosimetry Workshop has demonstrated remarkable progress in developing an international level of common approaches for retrospective dose estimations around the SNTS and in understanding the tasks for the future joint work in this direction. In the framework of a special session the problems of developing a database and registry in order to support epidemiological studies around SNTS were discussed. The results of investigation of psychological consequences of nuclear tests, which are expressed in the form of verbal behaviour, were presented at this session as well.
2013-09-09
dosimetry records, NDI’s operating procedures/instructions, and radiation safety training. c. Survey Personnel: (1) Health... Dosimetry . (1) Verify unshielded NDI safety procedures meet T.O. 33B-l-l and other occupational safety and health requirements. (2) Verify an...distribution is unlimited. Case Number: 88ABW-2013-3977, 9 Sep 2013 b. The electronic personal dosimeters (EPDs) worn by NDI personnel had
ERIC Educational Resources Information Center
MacKenzie, R. K.; Dowell, J.; Ayansina, D.; Cleland, J. A.
2017-01-01
Traditional methods of assessing personality traits in medical school selection have been heavily criticised. To address this at the point of selection, "non-cognitive" tests were included in the UK Clinical Aptitude Test, the most widely-used aptitude test in UK medical education (UKCAT: http://www.ukcat.ac.uk/). We examined the…
A parameterization method and application in breast tomosynthesis dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xinhua; Zhang, Da; Liu, Bob
2013-09-15
Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized usingmore » a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.« less
A national dosimetry audit for stereotactic ablative radiotherapy in lung.
Distefano, Gail; Lee, Jonny; Jafari, Shakardokht; Gouldstone, Clare; Baker, Colin; Mayles, Helen; Clark, Catharine H
2017-03-01
A UK national dosimetry audit was carried out to assess the accuracy of Stereotactic Ablative Body Radiotherapy (SABR) lung treatment delivery. This mail-based audit used an anthropomorphic thorax phantom containing nine alanine pellets positioned in the lung region for dosimetry, as well as EBT3 film in the axial plane for isodose comparison. Centres used their local planning protocol/technique, creating 27 SABR plans. A range of delivery techniques including conformal, volumetric modulated arc therapy (VMAT) and Cyberknife (CK) were used with six different calculation algorithms (collapsed cone, superposition, pencil-beam (PB), AAA, Acuros and Monte Carlo). The mean difference between measured and calculated dose (excluding PB results) was 0.4±1.4% for alanine and 1.4±3.4% for film. PB differences were -6.1% and -12.9% respectively. The median of the absolute maximum isodose-to-isodose distances was 3mm (-6mm to 7mm) and 5mm (-10mm to +19mm) for the 100% and 50% isodose lines respectively. Alanine and film is an effective combination for verifying dosimetric and geometric accuracy. There were some differences across dose algorithms, and geometric accuracy was better for VMAT and CK compared with conformal techniques. The alanine dosimetry results showed that planned and delivered doses were within ±3.0% for 25/27 SABR plans. Copyright © 2017 Elsevier B.V. All rights reserved.
Reconstructive dosimetry for cutaneous radiation syndrome
Lima, C.M.A.; Lima, A.R.; Degenhardt, Ä.L.; Valverde, N.J.; Da Silva, F.C.A.
2015-01-01
According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry. PMID:26445332
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kesner, A; Poli, G; Beykan, S
Purpose: As the field of Nuclear Medicine moves forward with efforts to integrate radiation dosimetry into clinical practice we can identify the challenge posed by the lack of standardized dose calculation methods and protocols. All personalized internal dosimetry is derived by projecting biodistribution measurements into dosimetry calculations. In an effort to standardize organization of data and its reporting, we have developed, as a sequel to the EANM recommendation of “Good Dosimetry Reporting”, a freely available biodistribution template, which can be used to create a common point of reference for dosimetry data. It can be disseminated, interpreted, and used for methodmore » development widely across the field. Methods: A generalized biodistribution template was built in a comma delineated format (.csv) to be completed by users performing biodistribution measurements. The template is available for free download. The download site includes instructions and other usage details on the template. Results: This is a new resource developed for the community. It is our hope that users will consider integrating it into their dosimetry operations. Having biodistribution data available and easily accessible for all patients processed is a strategy for organizing large amounts of information. It may enable users to create their own databases that can be analyzed for multiple aspects of dosimetry operations. Furthermore, it enables population data to easily be reprocessed using different dosimetry methodologies. With respect to dosimetry-related research and publications, the biodistribution template can be included as supplementary material, and will allow others in the community to better compare calculations and results achieved. Conclusion: As dosimetry in nuclear medicine become more routinely applied in clinical applications, we, as a field, need to develop the infrastructure for handling large amounts of data. Our organ level biodistribution template can be used as a standard format for data collection, organization, as well as for dosimetry research and software development.« less
NASA Astrophysics Data System (ADS)
Schreiner, L. J.
2017-05-01
For seventeen years a community of basic and clinical scientists and researchers has been meeting bi-annually to promote the clinical advance of techniques to measure radiation dose in three dimensions. The interest in this dosimetry was motivated by its promise as an effective methodology for 3D measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. Each of the International Conferences on 3D Radiation Dosimetry resulted in the publication of informative proceedings [1-8], the majority openly available on the internet. The proceedings included papers that: i) reviewed the basic science of the radiation sensitive materials used to accumulate the dose information, ii) introduced the science and engineering of the imaging systems required to read the information out, iii) described the work flows and systems required for efficient dosimetry, iv) reported the protocols required for reproducible dosimetry, and v) showed examples of clinical use illustrating advantage and limitations of the dosimetry. This paper is intended to use the framework provided by these proceedings to review the current 3D chemical dosimeters available and to discuss the requirements for their use. The paper describes how 3D dosimetry can complement other dose delivery validation approaches available in the clinic. It closes with some personal reflections of how the motivation for, and practice of, 3D dosimetry have changed (or not) over the years.
Lee, S Y; Lee, K J
2001-04-01
To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.
Thomas, Silke; Kühnlein, Anja; Heinrich, Sabine; Praml, Georg; von Kries, Rüdiger; Radon, Katja
2008-11-04
Despite the increase of mobile phone use in the last decade and the growing concern whether mobile telecommunication networks adversely affect health and well-being, only few studies have been published that focussed on children and adolescents. Especially children and adolescents are important in the discussion of adverse health effects because of their possibly higher vulnerability to radio frequency electromagnetic fields. We investigated a possible association between exposure to mobile telecommunication networks and well-being in children and adolescents using personal dosimetry. A population-based sample of 1.498 children and 1.524 adolescents was assembled for the study (response 52%). Participants were randomly selected from the population registries of four Bavarian (South of Germany) cities and towns with different population sizes. During a Computer Assisted Personal Interview data on participants' well-being, socio-demographic characteristics and potential confounder were collected. Acute symptoms were assessed three times during the study day (morning, noon, evening).Using a dosimeter (ESM-140 Maschek Electronics), we obtained an exposure profile over 24 hours for three mobile phone frequency ranges (measurement interval 1 second, limit of determination 0.05 V/m) for each of the participants. Exposure levels over waking hours were summed up and expressed as mean percentage of the ICNIRP (International Commission on Non-Ionizing Radiation Protection) reference level. In comparison to non-participants, parents and adolescents with a higher level of education who possessed a mobile phone and were interested in the topic of possible adverse health effects caused by mobile telecommunication network frequencies were more willing to participate in the study. The median exposure to radio frequency electromagnetic fields of children and adolescents was 0.18% and 0.19% of the ICNIRP reference level respectively. In comparison to previous studies this is one of the first to assess the individual level of exposure to mobile telecommunication networks using personal dosimetry, enabling objective assessment of exposure from all sources and longer measurement periods. In total, personal dosimetry was proofed to be a well accepted tool to study exposure to mobile phone frequencies in epidemiologic studies including health effects on children and adolescents.
Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N
2017-12-01
An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Fundamentals of materials, techniques and instrumentation for OSL and FNTD dosimetry
NASA Astrophysics Data System (ADS)
Akselrod, M. S.
2013-02-01
The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al2O3:C as a material of choice for many dosimetric applications including fiberoptic OSL/RL sensors with diameters as small as 300 μm. A new RL/OSL fiberoptic system has a high potential for in vivo and in vitro dosimetry in both radiation therapy and diagnostic mammography. Different aspects of instrumentation, data processing algorithms, post-irradiation and real-time measurements are described. The next technological breakthrough was done with Fluorescent Nuclear Track detectors (FNTD) that has some important advantages in measuring fast neutron and high energy heavy charge particles that became the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology were engineered and successfully demonstrated for occupational and accident dosimetry, for medical dosimetry and radiobiological research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rathbone, Bruce A.; Morley, Shannon M.; Stephens, John A.
The Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimetry intercomparison exercise held at the Nevada National Security Site (NNSS) May 24-27, 2016. The exercise was administered by Lawrence Livermore National Laboratory (LLNL) and consisted of three exposures performed using the Godiva-IV critical assembly housed in the Device Assembly Facility (DAF) located on the NNSS site. The exercise allowed participants to test the ability of their nuclear accident dosimeters to meet the performance criteria in ANSI/HPS N13.3-2013, Dosimetry for Criticality Accidents and to obtain new measurement data for use in revising dose calculation methods and quick sort screeningmore » methods where appropriate. PNNL participated with new prototype Personal Nuclear Accident Dosimeter (PNAD) and Fixed Nuclear Accident Dosimeter (FNAD) designs as well as the existing historical PNAD design. The new prototype designs incorporate optically stimulated luminescence (OSL) dosimeters in place of thermoluminescence dosimeters (TLDs), among other design changes, while retaining the same set of activation foils historically used. The default dose calculation methodology established decades ago for use with activation foils in PNNL PNADs and FNADs was used to calculate neutron dose results for both the existing and prototype dosimeters tested in the exercise. The results indicate that the effective cross sections and/or dose conversion factors used historically need to be updated to accurately measure the operational quantities recommended for nuclear accident dosimetry in ANSI/HPS N13.3-2013 and to ensure PNAD and FNAD performance meets the ANSI/HPS N13.3-2013 performance criteria. The operational quantities recommended for nuclear accident dosimetry are personal absorbed dose, Dp(10), and ambient absorbed dose, D*(10).« less
Consultant-Client Relationships in UK SMEs: The Roles of the Personal Business Adviser
ERIC Educational Resources Information Center
Malone, Stephen A.
2012-01-01
This article reports on research into the role and value of a particular type of business consultant: a UK government-sponsored Personal Business Adviser (PBA). While it is an occupation that is now defunct in the UK, the author argues that its abolition may have been premature. The roles of the PBA are identified and are found to be in line with…
Mason, M D; Moore, R; Jones, G; Lewis, G; Donovan, J L; Neal, D E; Hamdy, F C; Lane, J A; Staffurth, J N
2016-09-01
The treatment of prostate cancer has evolved markedly over the last 40 years, including radiotherapy, notably with escalated dose and targeting. However, the optimal treatment for localised disease has not been established in comparative randomised trials. The aim of this article is to describe the history of prostate radiotherapy trials, including their quality assurance processes, and to compare these with the ProtecT trial. The UK ProtecT randomised trial compares external beam conformal radiotherapy, surgery and active monitoring for clinically localised prostate cancer and will report on the primary outcome (disease-specific mortality) in 2016 following recruitment between 1999 and 2009. The embedded quality assurance programme consists of on-site machine dosimetry at the nine trial centres, a retrospective review of outlining and adherence to dose constraints based on the trial protocol in 54 participants (randomly selected, around 10% of the total randomised to radiotherapy, n = 545). These quality assurance processes and results were compared with prostate radiotherapy trials of a comparable era. There has been an increasingly sophisticated quality assurance programme in UK prostate radiotherapy trials over the last 15 years, reflecting dose escalation and treatment complexity. In ProtecT, machine dosimetry results were comparable between trial centres and with the UK RT01 trial. The outlining review showed that most deviations were clinically acceptable, although three (1.4%) may have been of clinical significance and were related to outlining of the prostate. Seminal vesicle outlining varied, possibly due to several prostate trials running concurrently with different protocols. Adherence to dose constraints in ProtecT was considered acceptable, with 80% of randomised participants having two or less deviations and planning target volume coverage was excellent. The ProtecT trial quality assurance results were satisfactory and comparable with trials of its era. Future trials should aim to standardise treatment protocols and quality assurance programmes where possible to reduce complexities for centres involved in multiple trials. Copyright © 2016. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmidt, M; Knutson, N; University of Rhode Island, Kingston, RI
2016-06-15
Purpose: Development of an in-house program facilitates a workflow that allows Electronic Portal Imaging Device (EPID) patient specific quality assurance (QA) measurements to be acquired and analyzed in the Portal Dosimetry Application (Varian Medical Systems, Palo Alto, CA) using a non-Aria Record and Verify (R&V) system (MOSAIQ, Elekta, Crawley, UK) to deliver beams in standard clinical treatment mode. Methods: Initial calibration of an in-house software tool includes characterization of EPID dosimetry parameters by importing DICOM images of varying delivered MUs to determine linear mapping factors in order to convert image pixel values to Varian-defined Calibrated Units (CU). Using this information,more » the Portal Dose Image Prediction (PDIP) algorithm was commissioned by converting images of various field sizes to output factors using the Eclipse Scripting Application Programming Interface (ESAPI) and converting a delivered configuration fluence to absolute dose units. To verify the algorithm configuration, an integrated image was acquired, exported directly from the R&V client, automatically converted to a compatible, calibrated dosimetric image, and compared to a PDIP calculated image using Varian’s Portal Dosimetry Application. Results: For two C-Series and one TrueBeam Varian linear accelerators, gamma comparisons (global 3% / 3mm) of PDIP algorithm predicted dosimetric images and images converted via the inhouse system demonstrated agreement for ≥99% of all pixels, exceeding vendor-recommended commissioning guidelines. Conclusion: Combinations of a programmatic image conversion tool and ESAPI allow for an efficient and accurate method of patient IMRT QA incorporating a 3rd party R&V system.« less
Short-Term Medical Consequences of the Chernobyl Nuclear Accident: Lessons for the Future
Gale, Robert Peter
1988-01-01
The author of this article discusses the world's most serious nuclear accident to date: the Chernobyl nuclear accident of April 1986. His major focus is on the short-term medical consequences of the accident, including reduction of exposure to persons at risk, evaluation of persons potentially affected, dosimetry, and specific medical interventions. PMID:21253129
Díez, P; Aird, E G A; Sander, T; Gouldstone, C A; Sharpe, P H G; Lee, C D; Lowe, G; Thomas, R A S; Simnor, T; Bownes, P; Bidmead, M; Gandon, L; Eaton, D; Palmer, A L
2017-11-09
A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre's treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192 Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60 Co source, (Co0.A86). Alanine measurements when compared to the centres' calculated dose showed a mean difference (±SD) of +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%-4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.
Micro-Fabricated Solid-State Radiation Detectors for Active Personal Dosimetry
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.; Chen, Liang-Yu
2007-01-01
Active radiation dosimetry is important to human health and equipment functionality for space applications outside the protective environment of a space station or vehicle. This is especially true for long duration missions to the moon, where the lack of a magnetic field offers no protection from space radiation to those on extravehicular activities. In order to improve functionality, durability and reliability of radiation dosimeters for future NASA lunar missions, single crystal silicon carbide devices and scintillating fiber detectors are currently being investigated for applications in advanced extravehicular systems. For many years, NASA Glenn Research Center has led significant efforts in silicon carbide semiconductor technology research and instrumentation research for sensor applications under extreme conditions. This report summarizes the technical progress and accomplishments toward characterization of radiation-sensing components for the recommendation of their fitness for advanced dosimetry development.
Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akselrod, M. S.
The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al{sub 2}O{sub 3}:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties,more » instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.« less
Fundamentals of Materials, Techniques, and Instrumentation for OSL and FNTD Dosimetry
NASA Astrophysics Data System (ADS)
Akselrod, M. S.
2011-05-01
The optically stimulated luminescence (OSL) technique has already become a successful commercial tool in personal radiation dosimetry, medical dosimetry, diagnostic imaging, geological and archeological dating. This review briefly describes the history and fundamental principles of OSL materials, methods and instrumentation. The advantages of OSL technology and instrumentation in comparison with thermoluminescent technique are analyzed. Progress in material and detector engineering has allowed new and promising developments regarding OSL applications in the medical field. Special attention is dedicated to Al2O3:C as a material of choice for many dosimetric applications. Different aspects of OSL theory, materials optical and dosimetric properties, instrumentation, and data processing algorithms are described. The next technological breakthrough was done with Fluorescent Nuclear Track Detectors (FNTD) that have some important advantages in measuring fast neutron and high energy heavy charge particles that have become the latest tool in radiation therapy. New Mg-doped aluminum oxide crystals and novel type of imaging instrumentation for FNTD technology are discussed with regard to application in mixed neutron-gamma fields, medical dosimetry and radiobiological research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montégiani, Jean-François; Gaudin, Émilie; Després, Philippe
2014-08-15
In peptide receptor radionuclide therapy (PRRT), huge inter-patient variability in absorbed radiation doses per administered activity mandates the utilization of individualized dosimetry to evaluate therapeutic efficacy and toxicity. We created a reliable GPU-calculated dosimetry code (irtGPUMCD) and assessed {sup 177}Lu-octreotate renal dosimetry in eight patients (4 cycles of approximately 7.4 GBq). irtGPUMCD was derived from a brachytherapy dosimetry code (bGPUMCD), which was adapted to {sup 177}Lu PRRT dosimetry. Serial quantitative single-photon emission computed tomography (SPECT) images were obtained from three SPECT/CT acquisitions performed at 4, 24 and 72 hours after {sup 177}Lu-octreotate administration, and registered with non-rigid deformation of CTmore » volumes, to obtain {sup 177}Lu-octreotate 4D quantitative biodistribution. Local energy deposition from the β disintegrations was assumed. Using Monte Carlo gamma photon transportation, irtGPUMCD computed dose rate at each time point. Average kidney absorbed dose was obtained from 1-cm{sup 3} VOI dose rate samples on each cortex, subjected to a biexponential curve fit. Integration of the latter time-dose rate curve yielded the renal absorbed dose. The mean renal dose per administered activity was 0.48 ± 0.13 Gy/GBq (range: 0.30–0.71 Gy/GBq). Comparison to another PRRT dosimetry code (VRAK: Voxelized Registration and Kinetics) showed fair accordance with irtGPUMCD (11.4 ± 6.8 %, range: 3.3–26.2%). These results suggest the possibility to use the irtGPUMCD code in order to personalize administered activity in PRRT. This could allow improving clinical outcomes by maximizing per-cycle tumor doses, without exceeding the tolerable renal dose.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atari, N.A.; Ettinger, K.V.
When some irradiated solids are dissolved in water or certain other solvents light emission occurs, which is termed lyoluminescence''. In the case of inorganic materials, such as alkali halides, reactions of trapped electrons from F-centers are responsible for the light emission, and with organic materials, such as saccharides, trapped free radicals are involved. Application of lyoluminescence'' to dosimetry is described. It is possible to measure doses of between 1 and 10/sup 7/is way with an accuracy of 5% using NaCl with water as solvent. The stored lyoluminescent energy in NaCl decreases by only 15% after seven months of storage, butmore » is sensitive to optical and thermal bleaching. Furthermore, the effective ntomic numbers of NaCl is approximately 16, differing considerably from that of human tissue (above 7.5). Study of monosaccarides, including glucose, xylose and mannose, has demonstrated the stability of the trapped free radicals, and no decrease in their lyoluminescence was observed over 7 months. As regards their use for dosimetry they show linear dependence with dose up to 100 kR, and the lowest dose indicated under test was 100 R. It is considered possible to use the lyoluminescence of saccharides for clinical dosimetry if the sensitivity of the systems could be improved, and to this end tests were carried out using luminol solution. Using a /sup 60/Co gamma -source irradiated saccharides give bright blue light when dissolved in luminol solution, and the light enhancement was about 10/sup 6/ compared with water. It seems likely that the oxidizing species responsible for exciting the luminol are formed as a result of free radical reactions with dissolved or adsorbed O/sub 2/ in the system. Trehalose, which is a fairly true tissue equivalent material, appears to be a good candidate for lyoluminescence dosimetry. (UK)« less
Thomas, Silke; Kühnlein, Anja; Heinrich, Sabine; Praml, Georg; Nowak, Dennis; von Kries, Rüdiger; Radon, Katja
2008-09-01
The use of mobile phone telecommunication has increased in recent years. In parallel, there is growing concern about possible adverse health effects of cellular phone networks. We used personal dosimetry to investigate the association between exposure to mobile phone frequencies and well-being in adults. A random population-based sample of 329 adults living in four different Bavarian towns was assembled for the study. Using a dosimeter (ESM-140 Maschek Electronics), we obtained an exposure profile over 24 h for three mobile phone frequency ranges (measurement interval 1 s, limit of determination 0.05 V/m). Exposure levels over waking hours were totalled and expressed as mean percentage of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level. Each participant reported acute symptoms in a day-long diary. Data on five groups of chronic symptoms and potential confounders were assessed during an interview. The overall exposure to high-frequency electromagnetic fields was markedly below the ICNIRP reference level. We did not find any statistically significant association between the exposure and chronic symptoms or between the exposure and acute symptoms. Larger studies using mobile phone dosimetry are warranted to confirm these findings. Copyright 2008 Wiley-Liss, Inc.
Pediatric personalized CT-dosimetry Monte Carlo simulations, using computational phantoms
NASA Astrophysics Data System (ADS)
Papadimitroulas, P.; Kagadis, G. C.; Ploussi, A.; Kordolaimi, S.; Papamichail, D.; Karavasilis, E.; Syrgiamiotis, V.; Loudos, G.
2015-09-01
The last 40 years Monte Carlo (MC) simulations serve as a “gold standard” tool for a wide range of applications in the field of medical physics and tend to be essential in daily clinical practice. Regarding diagnostic imaging applications, such as computed tomography (CT), the assessment of deposited energy is of high interest, so as to better analyze the risks and the benefits of the procedure. The last few years a big effort is done towards personalized dosimetry, especially in pediatric applications. In the present study the GATE toolkit was used and computational pediatric phantoms have been modeled for the assessment of CT examinations dosimetry. The pediatric models used come from the XCAT and IT'IS series. The X-ray spectrum of a Brightspeed CT scanner was simulated and validated with experimental data. Specifically, a DCT-10 ionization chamber was irradiated twice using 120 kVp with 100 mAs and 200 mAs, for 1 sec in 1 central axial slice (thickness = 10mm). The absorbed dose was measured in air resulting in differences lower than 4% between the experimental and simulated data. The simulations were acquired using ˜1010 number of primaries in order to achieve low statistical uncertainties. Dose maps were also saved for quantification of the absorbed dose in several children critical organs during CT acquisition.
NASA Astrophysics Data System (ADS)
Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew
2013-10-01
A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.
Palmer, Antony L; Lee, Chris; Ratcliffe, Ailsa J; Bradley, David; Nisbet, Andrew
2013-10-07
A novel phantom is presented for 'full system' dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.
Klemic, Gladys [Naperville, IL; Bailey, Paul [Chicago, IL; Breheny, Cecilia [Yonkers, NY
2008-09-02
The present invention relates to a citizen's dosimeter. More specifically, the invention relates to a small, portable, personal dosimetry device designed to be used in the wake of a event involving a Radiological Dispersal Device (RDD), Improvised Nuclear Device (IND), or other event resulting in the contamination of large area with radioactive material or where on site personal dosimetry is required. The card sized dosimeter generally comprises: a lower card layer, the lower card body having an inner and outer side; a upper card layer, the layer card having an inner and outer side; an optically stimulated luminescent material (OSLM), wherein the OSLM is sandwiched between the inner side of the lower card layer and the inner side of the upper card layer during dosimeter radiation recording, a shutter means for exposing at least one side of the OSLM for dosimeter readout; and an energy compensation filter attached to the outer sides of the lower and upper card layers.
EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS
Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim
2009-01-01
The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed “accident doses”, were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy. PMID:19590746
EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS.
Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim; Simon, Steven L
2007-07-01
The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed "accident doses", were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy.
HosseiniAliabadi, S J; Hosseini Pooya, S M; Afarideh, H; Mianji, F
2015-06-01
The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. This system can be utilized in large scale environmental monitoring with a higher accuracy.
Radiation accident dosimetry on plastics by EPR spectrometry.
Trompier, F; Bassinet, C; Clairand, I
2010-02-01
In case of acute exposure to ionizing radiation, the dose absorbed by the victims has to be rapidly and accurately assessed in order to choose an appropriate medical treatment. Tooth enamel and bone biopsies measured by EPR spectrometry are often used as dose indicators, due to the good radiation sensitivity and the stability of EPR radiation-sensitive signals. Nevertheless, the invasive sampling of teeth and bones limits the application of this technique to retrospective dosimetry. Therefore, we have investigated an alternative non-invasive methodology. We have surveyed with EPR spectrometry the dosimetric properties of the plastics that can be found in personal effects such as glasses (CR-39, polycarbonate), mobile phones (PMMA, polycarbonate), watches and buttons. Dose response, signal stability and effects of storage conditions were investigated. Significant signal fading limits the use for radiation accident dosimetry. Few plastics present the required characteristics to be used in case of a radiation accident.
ERIC Educational Resources Information Center
Parag, Yael; Capstick, Stuart; Poortinga, Wouter
2011-01-01
A comparative experiment in the UK examined people's willingness to change energy consumption behavior under three different policy framings: energy tax, carbon tax, and personal carbon allowances (PCA). PCA is a downstream cap-and-trade policy proposed in the UK, in which emission rights are allocated to individuals. We hypothesized that due to…
Thermoluminescence dosimetry and its applications in medicine--Part 2: History and applications.
Kron, T
1995-03-01
Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of microGy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. Therefore TLD is a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review (Australas. Phys. Eng. Sci. Med. 17: 175-199, 1994).
ERIC Educational Resources Information Center
Francis, Leslie J.; Village, Andrew; Parker, Stephen G.
2017-01-01
This study set out to explore the trajectory of personal, moral and spiritual values of students taking Religious Studies at A level in the UK. A sample of 150 students completed a battery of measures at the beginning of their period of A level study and again at the end. The data found no difference over this period of time in personal values…
Heinrich, Sabine; Thomas, Silke; Heumann, Christian; von Kries, Rüdiger; Radon, Katja
2011-01-01
A possible influence of radio frequency electromagnetic field (RF EMF) exposure on health outcomes was investigated in various studies. The main problem of previous studies was exposure assessment. The aim of our study was the investigation of a possible association between RF EMF and chronic well-being in young persons using personal dosimetry. 3022 children and adolescents were randomly selected from the population registries of four Bavarian cities in Germany (participation 52%). Personal interview data on chronic symptoms, socio-demographic characteristics and potential confounders were collected. A 24-h radio frequency exposure profile was generated using a personal dosimeter. Exposure levels over waking hours were expressed as mean percentage of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference level. Half of the children and nearly every adolescent owned a mobile phone which was used only for short durations per day. Measured exposure was far below the current ICNIRP reference levels. The most reported chronic symptom in children and adolescents was fatigue. No statistically significant association between measured exposure and chronic symptoms was observed. Our results do not indicate an association between measured exposure to RF EMF and chronic well-being in children and adolescents. Prospective studies investigating potential long-term effects of RF EMF are necessary to confirm our results. Copyright © 2010 Elsevier Ltd. All rights reserved.
Teaching the Personal Science: From Impeccable Trivia to the Blooming Buzzing Confusion
ERIC Educational Resources Information Center
Banyard, Philip
2010-01-01
The argument presented here is that the teaching of psychology in the UK is focused on the learning of technical skills and is missing the opportunity to enthuse and inspire students in the personal science. This focus mirrors a general educational drive in the UK towards achievement at external examinations which are assessed by narrow cognitive…
ERIC Educational Resources Information Center
Hilsdon, John
2012-01-01
It is claimed that Personal Development Planning (PDP) is the only approach to learning in UK higher education that has been actively encouraged through a policy. This paper reviews the background to the development of PDP as policy, under conditions described as the "new moral economy", and the impact of these conditions on contemporary…
NASA Astrophysics Data System (ADS)
Turák, O.; Osvay, M.; Ballay, L.
2012-09-01
Radiation exposure of medical staff during cardiological and radiological procedures was investigated. The exposure of medical staff is directly connected to patient exposure. The aim of this study was to determine the distribution of doses on uncovered part of body of medical staff using LiF thermoluminescent (TL) dosimeters in seven locations. Individual Kodak film dosimeters (as authorized dosimetry system) were used for the assessment of medical staff's effective dose. Results achieved on dose distribution measurements confirm that wearing only one film badge under the lead apron does not provide enough information on the personal dose. The value of estimated annual doses on eye lens and extremities (fingers) were in good correlation with international publications.
Ambient Dose Equivalent in S. Paulo and Bauru cities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umisedo, Nancy K.; Okuno, Emico; Cancio, Francisco S.
2008-08-07
The Laboratory of Dosimetry (Institute of Physics, University of S. Paulo) performs since 1981 the external individual monitoring of workers exposed to X and gamma rays based on thermoluminescent dosimetry (TLD). Personal dose equivalent refers only to the exposure of workers due to the working activities, and the dose due to background radiation, also measured with TLD, must be subtracted to evaluate it. A compilation of ambient dose equivalent was done to evaluate the dose due to the background radiation in the work places, and also to contribute to the knowledge of the level of indoor radiation to which themore » public is exposed.« less
RENEB - Running the European Network of biological dosimetry and physical retrospective dosimetry.
Kulka, Ulrike; Abend, Michael; Ainsbury, Elizabeth; Badie, Christophe; Barquinero, Joan Francesc; Barrios, Lleonard; Beinke, Christina; Bortolin, Emanuela; Cucu, Alexandra; De Amicis, Andrea; Domínguez, Inmaculada; Fattibene, Paola; Frøvig, Anne Marie; Gregoire, Eric; Guogyte, Kamile; Hadjidekova, Valeria; Jaworska, Alicja; Kriehuber, Ralf; Lindholm, Carita; Lloyd, David; Lumniczky, Katalin; Lyng, Fiona; Meschini, Roberta; Mörtl, Simone; Della Monaca, Sara; Monteiro Gil, Octávia; Montoro, Alegria; Moquet, Jayne; Moreno, Mercedes; Oestreicher, Ursula; Palitti, Fabrizio; Pantelias, Gabriel; Patrono, Clarice; Piqueret-Stephan, Laure; Port, Matthias; Prieto, María Jesus; Quintens, Roel; Ricoul, Michelle; Romm, Horst; Roy, Laurence; Sáfrány, Géza; Sabatier, Laure; Sebastià, Natividad; Sommer, Sylwester; Terzoudi, Georgia; Testa, Antonella; Thierens, Hubert; Turai, Istvan; Trompier, François; Valente, Marco; Vaz, Pedro; Voisin, Philippe; Vral, Anne; Woda, Clemens; Zafiropoulos, Demetre; Wojcik, Andrzej
2017-01-01
A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.
ERIC Educational Resources Information Center
Hughes, Julie; Herrington, Margaret; McDonald, Tess; Rhodes, Amy
2011-01-01
This paper analyses the use of an e-portfolio system in contributing to the personalized learning of two dyslexic learners at the University of Wolverhampton, UK. The rationale for this research rests at the intersection of generic findings from e-portfolio (and wider e-learning) research and the still challenging project in higher education (HE)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, Hsu-Chi; Phalen, R.F.; Chang, I.
1995-12-01
The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Althoughmore » this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny ({approximately} 1 nm) to particles larger than 100 {mu}m. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar.« less
NASA Astrophysics Data System (ADS)
Díez, P.; Aird, E. G. A.; Sander, T.; Gouldstone, C. A.; Sharpe, P. H. G.; Lee, C. D.; Lowe, G.; Thomas, R. A. S.; Simnor, T.; Bownes, P.; Bidmead, M.; Gandon, L.; Eaton, D.; Palmer, A. L.
2017-12-01
A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre’s treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60Co source, (Co0.A86). Alanine measurements when compared to the centres’ calculated dose showed a mean difference (±SD) of +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%-4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.
NASA Technical Reports Server (NTRS)
Schaefer, H. J.
1974-01-01
The complexity of direct reading and passive dosimeters for monitoring radiation is studied to strike the right balance of compromise to simplify the monitoring procedure. Trapped protons, tissue disintegration stars, and neutrons are analyzed.
PREFACE: 8th International Conference on 3D Radiation Dosimetry (IC3DDose)
NASA Astrophysics Data System (ADS)
Olsson, Lars E.; Bäck, S.; Ceberg, Sofie
2015-01-01
IC3DDose 2014, the 8th International Conference on 3D Radiation Dosimetry was held in Ystad, Sweden, from 4-7 September 2014. This grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The 7th and last meeting was held in Sydney, Australia from 4-8 November 2012. It is worth remembering that the conference series started at the very beginning of the intensity modulated radiotherapy era and that the dosimeters being developed then were, to some extent, ahead of the clinical need of radiotherapy. However, since then the technical developments in radiation therapy have been dramatic, with dynamic treatments, including tracking, gating and volumetric modulated arc therapy, widely introduced in the clinic with the need for 3D dosimetry thus endless. This was also reflected by the contributions at the meeting in Ystad. Accordingly the scope of the meeting has also broadened to IC3DDOSE - I See Three-Dimensional Dose. A multitude of dosimetry techniques and radiation detectors are now represented, all with the common denominator: three-dimensional or 3D. Additionally, quality assurance (QA) procedures and other aspects of clinical dosimetry are represented. The implementation of new dosimetric techniques in radiotherapy is a process that needs every kind of caution, carefulness and thorough validation. Therefore, the clinical needs, reformulated as the aims for IC3DDOSE - I See Three-Dimensional Dose, are: • Enhance the quality and accuracy of radiation therapy treatments through improved clinical dosimetry. • Investigate and understand the dosimetric challenges of modern radiation treatment techniques. • Provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry. • Energize and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D, and semi-3D dosimetry techniques. We commend these IC3Dose 2014 conference proceedings to you and strongly believe they include significant contributions to scientific progress in this field. We would like to express our sincere gratitude to everybody involved in making the conference possible, the Scientific committee for their work on the general planning, paper review and program formulation, the distinguished invited speakers for their contributions and the local organizing committee members for all their hard work on the practical preparation for the meeting. Lars E. Olsson, Sven Bäck and Sofie Ceberg Lund University and Skåne University Hospital, Sweden International Scientific Committee Sven Bäck, Sweden (chair) Clive Baldock, Australia Sam Beddar, USA Crister Ceberg, Sweden Yves de Deene, Belgium/Australia Simon Doran, UK Geoffrey Ibbott, USA Andrew Jirasek, Canada Kevin Jordan, Canada Martin Lepage, Canada Daniel Low, USA Mark Oldham, USA Tony Popescu, Canada John Schreiner, Canada Cheng-Shie Wuu, USA David Thwaites, Australia Local Organizing Committee Sofie Ceberg (chair) Lars E. Olsson (conference chair) Fredrik Nordstrom Anneli Edvardsson Anna Karlsson Hauer Anna Bäck
HosseiniAliabadi, S. J.; Hosseini Pooya, S. M.; Afarideh, H.; Mianji, F.
2015-01-01
Introduction The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion This system can be utilized in large scale environmental monitoring with a higher accuracy. PMID:26157729
PREFACE: 7th International Conference on 3D Radiation Dosimetry (IC3DDose)
NASA Astrophysics Data System (ADS)
Thwaites, David; Baldock, Clive
2013-06-01
IC3DDose 2013, the 7th International Conference on 3D Radiation Dosimetry held in Sydney, Australia from 4-8 November 2012, grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The aim of the first workshop was to bring together individuals, both researchers and users, with an interest in 3D radiation dosimetry techniques, with a mix of presentations from basic science to clinical applications, which has remained an objective for all of the meetings. One rationale of DosGel99 was stated as supporting the increasing clinical implementation of gel dosimetry, as the technique appeared, at that time, to be leaving the laboratories of gel dosimetry enthusiasts and entering clinical practice. Clearly by labelling the first workshop as the 1st, there was a vision of a continuing series, which has been fulfilled. On the other hand, the expectation of widespread clinical use of gel dosimetry has perhaps not been what was hoped for and anticipated. Nevertheless the rapidly increasing demand for advanced high-precision 3D radiotherapy technology and techniques has continued apace. The need for practical and accurate 3D dosimetry methods for development and quality assurance has only increased. By the 6th meeting, held in South Carolina in 2010, the Conference Scientific Committee recognised the wider developments in 3D systems and methods and decided to widen the scope, whilst keeping the same span from basic science to applications. This was signalled by a change of name from 'Dosgel' to 'IC3DDose', a name that has continued to this latest conference. The conference objectives were: to enhance the quality and accuracy of radiation therapy treatment through improved clinical dosimetry to investigate and understand the dosimetric challenges of modern radiation treatments to provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry to energise and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D and semi-3D dosimetry techniques We believe the conference program, with its excellent range of expert and specialist speakers, met these objectives. Thanks are due to all invited speakers for their participation, to the Local Organising Committee members for all their hard work in making the conference happen, particularly the small core administrative support group, and to the range of academic, organisation and commercial sponsors who generously supported the meeting. The Scientific Committee members are also thanked for reviewing the submitted manuscripts and for assisting in the editorial process. Finally, all who travelled to Sydney, Australia for the meeting are acknowledged for choosing to attend and contribute to making this a successful conference. Local Conference Organising Committee David Thwaites (Conference Convener) Clive Baldock Leanne Price Elizabeth Starkey May Whitaker Peter Greer Lois Holloway Phil Vial Robin Hill Conference Scientific Committee Sven Back (Sweden) Clive Baldock (Australia) Cheng-Shie Wuu (USA) Yves de Deene (Belgium) Simon Doran (UK) Geoffrey Ibbott (USA) Andrew Jirasek (Canada) Kevin Jordan (Canada) Martin Lepage (Canada) Mark Oldham (USA) Evangelos Pappas (Greece) John Schreiner (Canada) David Thwaites (Australia) David ThwaitesClive Baldock DirectorExecutive Dean Institute of Medical PhysicsFaculty of Science School of PhysicsMacquarie University University of SydneyNorth Ryde NSW 2006NSW 2109 AustraliaAustralia The PDF also contains the conference program.
Rodrigues, Laura C; Viviani, Laura; Dodds, Julie P; Evans, Meirion R; Hunter, Paul R; Gray, Jim J; Letley, Louise H; Rait, Greta; Tompkins, David S; O'Brien, Sarah J
2011-01-01
Objectives To estimate, overall and by organism, the incidence of infectious intestinal disease (IID) in the community, presenting to general practice (GP) and reported to national surveillance. Design Prospective, community cohort study and prospective study of GP presentation conducted between April 2008 and August 2009. Setting Eighty-eight GPs across the UK recruited from the Medical Research Council General Practice Research Framework and the Primary Care Research Networks. Participants 6836 participants registered with the 88 participating practices in the community study; 991 patients with UK-acquired IID presenting to one of 37 practices taking part in the GP presentation study. Main outcome measures IID rates in the community, presenting to GP and reported to national surveillance, overall and by organism; annual IID cases and GP consultations by organism. Results The overall rate of IID in the community was 274 cases per 1000 person-years (95% CI 254 to 296); the rate of GP consultations was 17.7 per 1000 person-years (95% CI 14.4 to 21.8). There were 147 community cases and 10 GP consultations for every case reported to national surveillance. Norovirus was the most common organism, with incidence rates of 47 community cases per 1000 person-years and 2.1 GP consultations per 1000 person-years. Campylobacter was the most common bacterial pathogen, with a rate of 9.3 cases per 1000 person-years in the community, and 1.3 GP consultations per 1000 person-years. We estimate that there are up to 17 million sporadic, community cases of IID and 1 million GP consultations annually in the UK. Of these, norovirus accounts for 3 million cases and 130 000 GP consultations, and Campylobacter is responsible for 500 000 cases and 80 000 GP consultations. Conclusions IID poses a substantial community and healthcare burden in the UK. Control efforts must focus particularly on reducing the burden due to Campylobacter and enteric viruses. PMID:21708822
Relevance of PET for pretherapeutic prediction of doses in peptide receptor radionuclide therapy.
Blaickner, Matthias; Baum, Richard P
2014-01-01
Personalized dosimetry in radionuclide therapy has gained much attention in recent years. This attention has also an impact on peptide receptor radionuclide therapy (PRRT). This article reviews the PET-based imaging techniques that can be used for pretherapeutic prediction of doses in PRRT. More specifically the usage of (86)Y, (90)Y, (68)Ga, and (44)Sc are discussed: their characteristics for PET acquisition, the available peptides for labeling, the specifics of the imaging protocols, and the experiences gained from phantom and clinical studies. These techniques are evaluated with regard to their usefulness for dosimetry predictions in PRRT, and future perspectives are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
A new paradigm in personal dosimetry using LiF:Mg,Cu,P.
Cassata, J R; Moscovitch, M; Rotunda, J E; Velbeck, K J
2002-01-01
The United States Navy has been monitoring personnel for occupational exposure to ionising radiation since 1947. Film was exclusively used until 1973 when thermoluminescence dosemeters were introduced and used to the present time. In 1994, a joint research project between the Naval Dosimetry Center, Georgetown University, and Saint Gobain Crystals and Detectors (formerly Bicron RMP formerly Harshaw TLD) began to develop a state of the art thermoluminescent dosimetry system. The study was conducted from a large-scale dosimetry processor point of view with emphasis on a systems approach. Significant improvements were achieved by replacing the LiF:Mg,Ti with LiF:Mg,Cu,P TL elements due to the significant sensitivity increase, linearity, and negligible hiding. Dosemeter filters were optimised for gamma and X ray energy discrimination using Monte Carlo modelling (MCNP) resulting in significant improvement in accuracy and precision. Further improvements were achieved through the use of neural-network based dose calculation algorithms. Both back propagation and functional link methods were implemented and the data compared with essentially the same results. Several operational aspects of the system are discussed, including (1) background subtraction using control dosemeters, (2) selection criteria for control dosemeters, (3) optimisation of the TLD readers, (4) calibration methodology, and (5) the optimisation of the heating profile.
Dosimetry and field matching for radiotherapy to the breast and superclavicular fossa
NASA Astrophysics Data System (ADS)
Winfield, Elizabeth
Radiotherapy for early breast cancer aims to achieve local disease control and decrease loco-regional recurrence rates. Treatment may be directed to breast or chest wall alone or, include regional lymph nodes. When using tangential fields to treat the breast a separate anterior field directed to the axilla and supraclavicular fossa (SCF) is needed to treat nodal areas. The complex geometry of this region necessitates matching of adjacent radiation fields in three dimensions. The potential exists for zones of overdosage or underdosage along the match line. Cosmetic results may be compromised if treatment fields are not accurately aligned. Techniques for field matching vary between centres in the UK. A study of dosimetry across the match line region using different techniques, as reported in the multi-centre START Trial Quality Assurance (QA) programme, was undertaken. A custom-made anthropomorphic phantom was designed to assess dose distribution in three dimensions using film dosimetry. Methods with varying degrees of complexity were employed to match tangential and SCF beams. Various techniques combined half beam blocking and machine rotations to achieve geometric alignment. Matching of asymmetric beams allowed a single isocentre technique to be used. Where field matching was not undertaken a gap between tangential and SCF fields was employed. Results demonstrated differences between techniques in addition to variations within the same technique between different centres. Geometric alignment techniques produced more homogenous dose distributions in the match region than gap techniques or those techniques not correcting for field divergence. For this multi-centre assessment of match plane techniques film dosimetry used in conjunction with a breast shaped phantom provided relative dose information. This study has highlighted the difficulties of matching treatment fields to achieve homogenous dose distribution through the region of the match plane and the degree of inhomogeneity as a consequence of a gap between treatment fields.
The Role of the Medical Physicist in Radiation Protection in Hospitals.
ERIC Educational Resources Information Center
Harrison, R. M.
1989-01-01
Described is the role of the medical physicist in five areas of medical application, including radiotherapy, nuclear medicine, diagnostic radiology, environmental radioactivity, and dosimetry and personal monitoring. The management contribution of the medical physicist is discussed. Provided are two examples of new techniques influencing radiation…
ERIC Educational Resources Information Center
Hargreaves, Eleanore
2010-01-01
This article examines interview data from 12 mentors/coaches and eight of their clients in order to explore a mentoring and coaching service among UK university staff. Both mentors/coaches and clients were administrative or academic employees of the Institute of Education or affiliated colleges at London University, UK. Their roles related to the…
Communicating with a deafblind person in an emergency.
Scott, J
1998-07-01
Deafblind UK is the association of deafblind and dual sensory impaired people in the UK. This paper presents advice on the best way to communicate with people who are disabled in this way, particularly in an emergency.
Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh
2017-06-15
Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (°C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (°C), Pre-heat Time (s), Heating Rate (°C/s), Maximum Temperature of Readout (°C), readout time (s) and Storage Temperature (°C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Chiavassa, S.; Aubineau-Lanièce, I.; Bitar, A.; Lisbona, A.; Barbet, J.; Franck, D.; Jourdain, J. R.; Bardiès, M.
2006-02-01
Dosimetric studies are necessary for all patients treated with targeted radiotherapy. In order to attain the precision required, we have developed Oedipe, a dosimetric tool based on the MCNPX Monte Carlo code. The anatomy of each patient is considered in the form of a voxel-based geometry created using computed tomography (CT) images or magnetic resonance imaging (MRI). Oedipe enables dosimetry studies to be carried out at the voxel scale. Validation of the results obtained by comparison with existing methods is complex because there are multiple sources of variation: calculation methods (different Monte Carlo codes, point kernel), patient representations (model or specific) and geometry definitions (mathematical or voxel-based). In this paper, we validate Oedipe by taking each of these parameters into account independently. Monte Carlo methodology requires long calculation times, particularly in the case of voxel-based geometries, and this is one of the limits of personalized dosimetric methods. However, our results show that the use of voxel-based geometry as opposed to a mathematically defined geometry decreases the calculation time two-fold, due to an optimization of the MCNPX2.5e code. It is therefore possible to envisage the use of Oedipe for personalized dosimetry in the clinical context of targeted radiotherapy.
Heat protection behaviour in the UK: results of an online survey after the 2013 heatwave.
Khare, Swarna; Hajat, Shakoor; Kovats, Sari; Lefevre, Carmen E; de Bruin, Wändi Bruine; Dessai, Suraje; Bone, Angie
2015-09-10
The Heatwave Plan for England provides guidance for personal and home protection measures during heatwaves. Although studies in the USA, Australia and Europe have surveyed heat-related behaviours during heatwaves, few have been conducted in the UK. This study assesses personal and housing (at-home) behaviour and housing characteristics of the UK population during the 2013 heatwave. This paper analyses data from 1497 respondents of an online survey on heat protection measures and behaviour. Participants were asked questions about their behaviour during the 2013 heatwave, the characteristics of their current housing as well as about any negative health outcomes experienced due to the hot weather. We used multinomial logit regression to analyse personal and home heat protection behaviour and logistic regression to analyse characteristics of participants' current home (installed air conditioner, curtains etc.). We stratified the outcomes by age, sex, ethnicity, income, education and regional location. In 2013, for all heat-related illness (except tiredness), a higher proportion of those in the younger age groups reported symptoms compared with those in the older age groups. Women, higher income groups and those with higher education levels were found to be more likely to report always/often taking personal heat protective measures. The elderly were less likely to take some personal and home protective measures but were more likely to live in insulated homes and open windows at night to keep their home cool. Our study has found a high level of awareness of the actions to take during heatwaves in the UK, and has identified important demographic indicators of sections of the UK population that might benefit from additional or more targeted information. The health agencies should attempt to provide better information about heatwaves to those vulnerable (elderly, those at risk living in London, low income earners) or identify any barriers that might be preventing them from undertaking protective behaviour.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voytchev, Miroslav; Ambrosi, P.; Behrens, R.
This paper presents IEC/SC 45B Radiation protection instrumentation and its standards for individual monitoring of ionising radiation: IEC 61526 Ed. 3 for active personal dosemeters and IEC 62387-1 for passive integrating dosimetry systems. The transposition of these standards as CENELEC (European) standards is also discussed together with the collaboration between IEC/SC 45B and ISO/TC 85/SC 2.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-29
... instruments for end users. This network of facilities ensures that every radiation detection instrument that... associated test-and-evaluation protocols for radiation detection, instrumentation, and personal dosimetry... intrusion. The NRC supports efforts to develop alternate forms of Cs-137 that would reduce the security...
Athermal fading of luminescence in Al2 O3 ceramic substrates
NASA Astrophysics Data System (ADS)
Terry, Ian; Kouroukla, Eftychia; Bailiff, Ian K.
2015-03-01
Retrospective dosimetry aims to reconstruct ionising radiation dose to populations following a radiological incident using materials not designed for that purpose. Sintered alumina ceramic can function as a dosimeter with its luminescence properties and related trapped charge storage mechanism. Its widespread use as a substrate in surface mount devices and incorporation in devices such as mobile phones make it a ubiquitous potential dosimeter. We investigated the optically (OSL) and thermally (TL) stimulated luminescence properties of sintered alumina substrates. In contrast to their single crystal analogue developed for personal dosimetry, Al2O3:C, the substrates exhibit a significant loss of trapped charge (fading) within hours following irradiation at RT that seriously limits their utility for dosimetry over an extended timescale. The fading rates of OSL and TL signals of 0402 resistors were analysed under various storage conditions (time and temperature), complemented by a study of their microstructure. The results support a model of athermal loss of trapped charge due to electron tunnelling from trapping states; this contrasting behaviour is attributed to a physical modification of the trap environment arising from the manufacturing process.
Three-dimensional radiation dosimetry based on optically-stimulated luminescence
NASA Astrophysics Data System (ADS)
Sadel, M.; Høye, E. M.; Skyt, P. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.
2017-05-01
A new approach to three-dimensional (3D) dosimetry based on optically-stimulated luminescence (OSL) is presented. By embedding OSL-active particles into a transparent silicone matrix (PDMS), the well-established dosimetric properties of an OSL material are exploited in a 3D-OSL dosimeter. By investigating prototype dosimeters in standard cuvettes in combination with small test samples for OSL readers, it is shown that a sufficient transparency of the 3D-OSL material can be combined with an OSL response giving an estimated >10.000 detected photons in 1 second per 1mm3 voxel of the dosimeter at a dose of 1 Gy. The dose distribution in the 3D-OSL dosimeters can be directly read out optically without the need for subsequent reconstruction by computational inversion algorithms. The dosimeters carry the advantages known from personal-dosimetry use of OSL: the dose distribution following irradiation can be stored with minimal fading for extended periods of time, and dosimeters are reusable as they can be reset, e.g. by an intense (bleaching) light field.
Assessment of radiation doses in the UK from the Fukushima Daiichi Nuclear accident.
Brown, J
2014-06-01
PHE has undertaken a simple dose assessment for members of the public living in the UK at the time of the accident at the Fukushima Daiichi nuclear power station in March 2011. PHE reported that there was no public health risk to the UK from the release of material from the accident in a statement made on 29 March 2013. This assessment confirms the initial estimate of the doses which were about the same as a person in the UK would receive in an hour from natural background.
Ciurlionis, Laura; Kirby, Anna M; Locke, Imogen; Venables, Karen; Yarnold, John R; Titley, Jenny; Bliss, Judith; Coles, Charlotte E
2015-01-01
Objective: IMPORT HIGH is a multicentre randomized UK trial testing dose-escalated intensity-modulated radiotherapy (IMRT) after tumour excision in females with early breast cancer and higher than average local recurrence risk. A survey was carried out to investigate the impact of this trial on the adoption of advanced breast radiotherapy (RT) techniques in the UK. Methods: A questionnaire was sent to all 26 IMPORT HIGH recruiting RT centres to determine whether the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. In order to compare the clinical practice of breast RT between IMPORT HIGH and non–IMPORT HIGH centres, parts of the Royal College of Radiologists (RCR) breast RT audit result were used in this study. Results: 26/26 participating centres completed the questionnaire. After joining the trial, the number of centres routinely using tumour bed clips to guide whole-breast RT rose from 5 (19%) to 21 (81%). 20/26 (77%) centres now contour target volumes and organs at risk (OARs) in some or all patients compared with 14 (54%) before the trial. 14/26 (54%) centres offer inverse-planned IMRT for selected non-trial patients with breast cancer, and 10/14 (71%) have adopted the IMPORT HIGH trial protocol for target volume and OARs dose constraints. Only 2/26 (8%) centres used clip information routinely for breast treatment verification prior to IMPORT HIGH, a minority that has since risen to 7/26 (27%). Data on 1386 patients was included from the RCR audit. This suggested that more cases from IMPORT HIGH centres had surgical clips implanted (83 vs 67%), were treated using CT guided planning with full three-dimensional dose compensation (100 vs 75%), and were treated with photon boost RT (30 vs 8%). Conclusion: The study suggests that participation in the IMPORT HIGH trial has played an important part in providing the guidance and support networks needed for the safe integration of advanced RT techniques, where appropriate, as a standard of care for breast cancer patients treated at participating cancer centres. Advances in knowledge: We investigated the impact of the IMPORT HIGH trial on the adoption of advanced breast RT techniques in the UK and the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. PMID:26492402
Tsang, Yat; Ciurlionis, Laura; Kirby, Anna M; Locke, Imogen; Venables, Karen; Yarnold, John R; Titley, Jenny; Bliss, Judith; Coles, Charlotte E
2015-01-01
IMPORT HIGH is a multicentre randomized UK trial testing dose-escalated intensity-modulated radiotherapy (IMRT) after tumour excision in females with early breast cancer and higher than average local recurrence risk. A survey was carried out to investigate the impact of this trial on the adoption of advanced breast radiotherapy (RT) techniques in the UK. A questionnaire was sent to all 26 IMPORT HIGH recruiting RT centres to determine whether the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. In order to compare the clinical practice of breast RT between IMPORT HIGH and non-IMPORT HIGH centres, parts of the Royal College of Radiologists (RCR) breast RT audit result were used in this study. 26/26 participating centres completed the questionnaire. After joining the trial, the number of centres routinely using tumour bed clips to guide whole-breast RT rose from 5 (19%) to 21 (81%). 20/26 (77%) centres now contour target volumes and organs at risk (OARs) in some or all patients compared with 14 (54%) before the trial. 14/26 (54%) centres offer inverse-planned IMRT for selected non-trial patients with breast cancer, and 10/14 (71%) have adopted the IMPORT HIGH trial protocol for target volume and OARs dose constraints. Only 2/26 (8%) centres used clip information routinely for breast treatment verification prior to IMPORT HIGH, a minority that has since risen to 7/26 (27%). Data on 1386 patients was included from the RCR audit. This suggested that more cases from IMPORT HIGH centres had surgical clips implanted (83 vs 67%), were treated using CT guided planning with full three-dimensional dose compensation (100 vs 75%), and were treated with photon boost RT (30 vs 8%). The study suggests that participation in the IMPORT HIGH trial has played an important part in providing the guidance and support networks needed for the safe integration of advanced RT techniques, where appropriate, as a standard of care for breast cancer patients treated at participating cancer centres. We investigated the impact of the IMPORT HIGH trial on the adoption of advanced breast RT techniques in the UK and the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification.
Current provision of care for older persons in A & E units in the UK.
Howe, C A
1998-10-01
This study investigates the state of care for older persons within Accident and Emergency (A & E) units in the UK. As the proportion of older persons in the population continues to inexorably increase, A & E units will be expected to cope with a greater number of older people than ever before. Are they prepared for this increase, and do they possess the skills, knowledge and environment to care adequately for older people and the many special problems they present? One hundred A & E units were surveyed by a postal questionnaire consisting of a benchmark of best practice deemed by literature search and expert opinion to be important in caring for older persons in A & E. The data produced gives an overall picture of the current provision of care for older persons in A & E units, and indicates to fellow A & E nursing professionals where current performance may be improved.
Prevalence and predictors of antiretroviral drug resistance in newly diagnosed HIV-1 infection.
Booth, Clare L; Garcia-Diaz, Ana M; Youle, Michael S; Johnson, Margaret A; Phillips, Andrew; Geretti, Anna Maria
2007-03-01
To determine prevalence and predictors of antiretroviral drug resistance in newly diagnosed individuals with HIV-1 infection, using a systematic approach to avoid selection bias. Plasma samples from all persons diagnosed HIV-1 seropositive at a large London centre between April 2004 and February 2006 underwent sequencing of HIV-1 reverse transcriptase (RT) and protease genes. Subtype was assigned by phylogenetic analysis. Resistance was scored according to the IAS-USA list (2005) modified to include T215revertants and exclude isolated E44D or V118I and minor protease mutations. Recent seroconversion was identified by HIV antibody avidity testing. The cohort of 239 included 169 (70.7%) males, 126 (52.7%) homosexuals, 118 (49.5%) persons of white ethnicity and 144 (60.0%) persons born outside the UK. Subtypes included B 134 (56.1%), C 46 (19.2%), A 17 (7.1%), other non-B 42 (17.6%). The prevalence of resistance mutations was 17/239 (7.1%; 95% confidence interval 4.5-11.1%), comprising 10/239 (4.2%) nucleoside/nucleotide RT inhibitor (NRTI); 4/239 (1.7%) non-nucleoside RT inhibitor (NNRTI) and 4/239 (1.7%) protease inhibitor (PI) associated mutations. Dual-class (NRTI + PI) resistance mutations were detected in 1/239 (0.4%) person. The prevalence of resistance mutations was 7/85 (8.2%) and 10/154 (6.5%) in persons with recent and established infection, respectively. In multivariate analysis, having been born in the UK and high CD4 count, but not gender, age, risk group, ethnicity or subtype, were independent predictors of resistance. In an unselected UK cohort, subtypes other than B accounted for 43.9% of new HIV-1 diagnoses. The prevalence of resistance mutations was 7.1% and highest in those born in the UK.
A comparison of personal dose equivalent measurements made by personal dosemeters
NASA Astrophysics Data System (ADS)
Cechak, T.; Davidkova, J.; Kodl, O.; Novacek, P.; Papirnik, P.; Petrova, K.; Prasek, P.; Martincik, J.; Sochor, V.
2014-11-01
Individual monitoring services for external radiation were tested in the Czech Republic. The results of the tests show that they are dosimetry systems authorized and regularly tested in the Czech Republic having outliers for low energy region and angle of 50 degree and greater. With the highest probability, it can be stated that the processing equipment does not determine the angle of exposure reliably. These cases may have caused overestimations of Hp(10) in the special conditions occurring e.g. in interventional radiology and cardiology procedures.
Research and the problems of litter and medical wastes on the UK coastline.
Philipp, R; Pond, K; Rees, G
1997-01-01
Recent research has shown that recreational water and bathing beach quality are associated with injury, infection and personal well-being. Continued surveillance is essential to audit the environmental and associated health trends. In the Coastwatch UK project and since 1989, annual surveys each autumn have been undertaken during a two-week study period, into the extent of littering of the UK coastline. The Public Health Laboratory Service also collects data on the use of hepatitis B immunoglobulin. In these studies it is now possible to examine time trends. The findings are not reassuring. They help to justify present concern about the health effects of discarded litter and medical waste and fears that environmental degradation could lead to loss of income from tourism. In response, some health and local authorities have started public education programmes, supplying litter bins on or near bathing beaches, emptying them regularly and undertaking beach cleansing during the summer months. The UK government is also introducing new legislation that will require 6 mm fine mesh wire screens on all shore-based sewage outlets around the UK coastline. Continued monitoring is needed to assess the effectiveness of these interventions. The need for greater personal responsibility is particularly identified.
Experimental Procedures for Sensitive and Reproducible In Situ EPR Tooth Dosimetry
Williams, Benjamin B.; Sucheta, Artur; Dong, Ruhong; Sakata, Yasuko; Iwasaki, Akinori; Burke, Gregory; Grinberg, Oleg; Lesniewski, Piotr; Kmiec, Maciej; Swartz, Harold M.
2007-01-01
In vivo electron paramagnetic resonance (EPR) tooth dosimetry provides a means for non-invasive retrospective assessment of personal radiation exposure. While there is a clear need for such capabilities following radiation accidents, the most pressing need for the development of this technology is the heightened likelihood of terrorist events or nuclear conflicts. This technique will enable such measurements to be made at the site of an incident, while the subject is present, to assist emergency personnel as they perform triage for the affected population. At Dartmouth Medical School this development is currently being tested with normal volunteers with irradiated teeth placed in their mouths and with patients who have undergone radiation therapy. Here we describe progress in practical procedures to provide accurate and reproducible in vivo dose estimates. PMID:18591989
Eaton, David J; Tyler, Justine; Backshall, Alex; Bernstein, David; Carver, Antony; Gasnier, Anne; Henderson, Julia; Lee, Jonathan; Patel, Rushil; Tsang, Yatman; Yang, Huiqi; Zotova, Rada; Wells, Emma
2017-03-01
External dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems. Measurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array. A total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002±0.006. Average point dose agreement for clinical plans was -0.3±1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2mm, 3%/2mm and 3%/3mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy. An external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Human immunodeficiency virus infection in the United Kingdom: quarterly report 3.
1989-01-01
Up to 31 March 1988, 1429 cases meeting the World Health Organization/Centers for Disease Control (U.S.A.) definition of the acquired immune deficiency syndrome (AIDS) were reported in the U.K. of which 59 were in visitors and 1370 in U.K. residents. In the same period there were 8459 laboratory reports of human immunodeficiency virus (HIV) antibody-positive tests. Since 1985 the median interval of 2 months between diagnosis and report of AIDS has not changed. Most patients with Kaposi's sarcoma (KS) as an indicator disease when AIDS was diagnosed were homosexual/bisexual males; the proportion in this category has declined. The data support the hypothesis for a co-factor in the aetiology of KS in homosexual/bisexual males and that the effect of this co-factor has progressively weakened. Injecting drugs was a risk factor for 48 patients with AIDS (4%), half of whom were also homosexual/bisexual males, and for 1406 (17%) persons reported as HIV antibody-positive of whom 63 were also homosexual/bisexual males. HIV-infected persons injecting drugs were reported from all parts of the U.K., apart from Northern Ireland, but the cumulative rate per million population in Scotland for such persons was more than six times the rate elsewhere. In the collaborative laboratory study in England, 2.3% of over 3000 persons injecting drugs were HIV antibody-positive; among those who were asymptomatic the prevalence in London was 7.1% compared with 1.3% outside London. By 1987, the incidence rate of acute hepatitis B in persons injecting drugs in England had fallen to less than a third of that for 1985; in Scotland the figure for 1987 was only a quarter of that for 1985. Since the current rate of HIV transmission among persons in the U.K. injecting drugs is unknown, monitoring the prevalence of HIV in this risk group should be intensified.
Fang, Mingying; Oremus, Mark; Tarride, Jean-Eric; Raina, Parminder
2016-07-18
The use of the EQ-5D to asses the economic benefits of health technologies has led to questions about the cross-population transferability of preference weights to calculate health utility scores. The aim of this study is to investigate whether the use of UK and Canadian preference weights will lead to the calculation of different health utility scores in a sample of persons with Alzheimer's disease (AD) and their primary informal caregivers. We recruited 216 patient-caregiver dyads from nine geriatric and memory clinics across Canada. Participants used the EQ-5D-3L to rate their health-related quality-of-life (HRQoL). EQ-5D-3L responses were transformed into health utility scores using UK and Canadian preference weights. The levels of agreement between the two sets of scores were assessed using intraclass correlation coefficients (ICCs). Bland-Altman plots depicted individual-level differences between the two sets of scores. Differences in health utility scores were tested using the Wilcoxon signed rank sum test. A generalized linear model with a gamma distribution was used to examine whether participants' socio-demographic characteristics were associated with their health utility scores. The distributions of health utility scores derived from both the UK and Canadian preference weights were skewed to the left. The intraclass correlation coefficient was 0.94 (95 % CI: 0.92, 0.95) for persons with AD and 0.92 (95 % CI: 0.88, 0.94) for the caregivers. The Canadian weights yielded slightly higher median health utility scores than the UK weights for caregivers (median difference: 0.009; 95 % confidence interval: 0.007, 0.013). This finding persisted after stratifying by disease severity. Few socio-demographic characteristics were associated with the two sets of health utility scores. Health utility scores exhibited small and clinically unimportant differences when calculated with UK versus Canadian preference weights in persons with AD and their caregivers. The original UK and Canadian population samples used to obtain the preference weights valued health states similarly.
Exploring Foreign Undergraduate Students' Experiences of University
ERIC Educational Resources Information Center
Liu, Danica Wai Yee; Winder, Belinda
2014-01-01
Although international students are an important source of income to universities in the UK, the emotional impact of their experiences may be ignored and unacknowledged. This study explored the personal experiences of international students studying for an undergraduate degree in the UK. Semi-structured interviews with five participants were…
ERIC Educational Resources Information Center
Gibb, Allan A.
1987-01-01
Outlines programs in the United Kingdom (UK) designed to encourage the starting of small businesses. Successful programs help entrepreneurs obtain financial support, get business training, and develop a business plan. Recommends emphasis on personal competency and motivation training as well as shorter courses. (CH)
Tracking Streamer Blobs Into the Heliosphere
2010-05-20
SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Same as Report (SAR) 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE PERSON a. REPORT...NASA/GSFC (US), RAL (UK), UB- HAM (UK), MPS (Germany), CSL (Belgium), IOTA (France), and IAS (France). In the US, funding was provided by NASA, in the
"A sound track of your life": music in contemporary UK funerals.
Adamson, Sue; Holloway, Margaret
2012-01-01
This article considers the role that music plays in contemporary UK funerals and the meaning that the funeral music has for bereaved families. It is based on findings from a recently completed study of 46 funerals funded by the UK Arts and Humanities Research Council. Music contributes to the public ceremony and the personal existential quest of the bereaved. It is important to both the content and process of the contemporary funeral, an event of deep cultural significance in our response as individuals and communities to death and the loss of a significant relationship. There is evidence that for many people, the music chosen and used also evokes and conveys their spirituality. Spirituality may not be intrinsic to the music but spiritual experience may result from the meaning that the music has for that particular person.
Kane, Eddie; Reeder, Neil; Keane, Kimberley; Prince, Sharon
2016-08-01
In the UK, patients with personality disorders presenting complex needs frequently experience an unhelpful pattern of acute treatment followed by community care-with associated high cost implications for services. With UK mental health resources under severe pressure, this leaves commissioners with difficult decisions to make. Yet studies on cost-effectiveness in respect of personality disorder treatment are scarce, particularly for treatments taking place outside of major teaching hospitals in the USA. This paper studies the benefits of an intensive, holistic approach and finds that the Network achieved substantial reductions in health care usage and expenditure in the short to medium term. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
NASA Astrophysics Data System (ADS)
Minsky, D. M.; Valda, A.; Kreiner, A. J.; Burlon, A. A.; Green, S.; Wojnecki, C.; Ghani, Z.
2010-08-01
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the 10B body distribution which, in turn, is governed by the tumor specificity of the 10B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction 10B(n,α)7Li accounts for about 80 % of the total dose in a tumor with 40 ppm in 10B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical data and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from 7Li. For this purpose we designed, built and tested a prototype based on LaBr3(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
Čemusová, Z; Ekendahl, D; Judas, L
2016-09-01
As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and Hp(10), Hp(3) or Hp(0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ototoxic occupational exposures for a stock car racing team: I. Noise surveys.
Van Campen, Luann E; Morata, Thais; Kardous, Chucri A; Gwin, Kristin; Wallingford, Kenneth M; Dallaire, Jacques; Alvarez, Frank J
2005-08-01
The National Institute for Occupational Safety and Health (NIOSH) surveyed noise exposure for a professional stock car team at their race shop and during two races at one racetrack. At the team's shop, area sound pressure levels (SPLs) were measured for various work tasks. Equivalent levels (Leqs) ranged from 58 to 104 decibels, A-weighted (dBA). Personal noise dosimetry was conducted for at least one employee for each job description in race car assembly (n = 9). The Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 90 dBA for an 8-hour, 5-dB exchange rate time-weighted average (TWA) was never exceeded, but in two instances values exceeded OSHA's action level of 85 dBA for hearing conservation implementation. The NIOSH recommended exposure limit (REL) of 85 dBA for a 3-dB exchange rate Leq was exceeded for five of the measured jobs. During the races, SPLs averaged above 100 dBA in the pit area where cars undergo adjustments/refueling, both before and during the race. Peak levels reached 140 dB SPL. NIOSH REL was exceeded for every personal noise dosimetry measurement. Recommendations for hearing protection and communication are presented.
2007 Annual Health Physics Report for the HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2008-04-09
During the 2007 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection and technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2007, there were 172 person-trips that required dose monitoring of the U.S. monitors. Of the 172 person-trips, 160 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. There were 12 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. There were two monitoring visits (sourcemore » changes) that were back to back with 14 monitors. LLNL's Hazard Control Division laboratories provided the dosimetry services for the HEU Transparency monitors.« less
ERIC Educational Resources Information Center
O'Connor, Jane; Fotakopoulou, Olga
2016-01-01
The rise in personal ownership of touch-screen technology such as iPads and smartphones in the UK in recent years has led to the increasing use of such technology by babies and very young children. This article explores this practice via an online parental survey with 226 UK parents of children aged 0-3 years within the context of the current…
Implementing Shared Memory Parallelism in MCBEND
NASA Astrophysics Data System (ADS)
Bird, Adam; Long, David; Dobson, Geoff
2017-09-01
MCBEND is a general purpose radiation transport Monte Carlo code from AMEC Foster Wheelers's ANSWERS® Software Service. MCBEND is well established in the UK shielding community for radiation shielding and dosimetry assessments. The existing MCBEND parallel capability effectively involves running the same calculation on many processors. This works very well except when the memory requirements of a model restrict the number of instances of a calculation that will fit on a machine. To more effectively utilise parallel hardware OpenMP has been used to implement shared memory parallelism in MCBEND. This paper describes the reasoning behind the choice of OpenMP, notes some of the challenges of multi-threading an established code such as MCBEND and assesses the performance of the parallel method implemented in MCBEND.
Chicheportiche, Alexandre; Artoul, Faozi; Schwartz, Arnon; Grozinsky-Glasberg, Simona; Meirovitz, Amichay; Gross, David J; Godefroy, Jeremy
2018-06-19
Peptide receptor radionuclide therapy (PRRT) with [ 177 Lu]-DOTA-TATE is an effective treatment of neuroendocrine tumors (NETs). After each cycle of treatment, patient dosimetry evaluates the radiation dose to the risk organs, kidneys, and bone marrow, the most radiosensitive tissues. Absorbed doses are calculated from the radioactivity in the blood and from single photon emission computed tomography (SPECT) images corrected by computed tomography (CT) acquired after each course of treatment. The aim of this work is to assess whether the dosimetry along all treatment cycles can be calculated using a single CT. We hypothesize that the absorbed doses to the risk organs calculated with a single CT will be accurate enough to correctly manage the patients, i.e., whether or not to continue PRRT. Twenty-four patients diagnosed with metastatic NETs undergoing PRRT with [ 177 Lu]-DOTA-TATE were retrospectively included in this study. We compared radiation doses to the kidneys and bone marrow using two protocols. In the "classical" one, dosimetry is calculated based on a SPECT and a CT after each treatment cycle. In the new protocol, dosimetry is calculated based on a SPECT study after each cycle but with the first acquired CT for all cycles. The decision whether or not to stop PRRT because of unsafe absorbed dose to the risk organs would have been the same had the classical or the new protocol been used. The agreement between the cumulative doses to the kidneys and bone marrow obtained from the two protocols was excellent with Pearson's correlation coefficients r = 0.95 and r = 0.99 (P < 0.0001) and mean relative differences of 5.30 ± 6.20% and 0.48 ± 4.88%, respectively. Dosimetry calculations for a given patient can be done using a single CT registered to serial SPECTs. This new protocol reduces the need for a hybrid camera in the follow-up of patients receiving [ 177 Lu]-DOTA-TATE.
Greening Technology in U.K. Higher Education
ERIC Educational Resources Information Center
Bristow, Rob
2009-01-01
With the world focusing on climate change and individuals through to organizations questioning how they can reduce their personal and professional carbon footprints, JISC (Joint Information Systems Committee) is looking at how it can help U.K. education professionals learn from one another. In 2009, the final report from JISC's SusteIT study…
NASA Astrophysics Data System (ADS)
Mrozik, Anna; Marczewska, B.; Bilski, P.; Kłosowski, M.
2014-11-01
The rapid assessment of the radiation dose after unexpected exposure is a task of accidental dosimetry. In case of a radiological accident glasses originating from mobile phone screens, placed usually near the human body, could be used as emergency thermoluminescent (TL) personal dosimeters. The time between irradiation and TL readout is crucial and therefore preparation of the mobile phone screens and their readout conditions should be optimized. The influence of the samples etching, bleaching and selection of the optical filters based on measurement of the emission spectrum of irradiated glass samples during heating for different types of mobile phones were the subjects of our investigation. Obtained results showed that glasses extracted from different brands of mobile phones have different dosimetric properties but all of them give a luminescent signal which can be used to calculate the dose.
da Silva, Teógenes A; Guimarães, Margarete C; Meireles, Leonardo S; Teles, Luciana L D; Lacerda, Marco Aurélio S
2016-11-01
A new regulatory statement was issued concerning the eye lens radiation protection of persons in planned exposures. A debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to establish the individual monitoring procedure with the EYE-D™ holder and a MCP-N LiF:Mg,Cu,P thermoluminescent chip detector for measuring the personal dose equivalent H p (3) in workers of a Positron Emission Tomography Radiopharmaceutical Production Facility. Copyright © 2016 Elsevier Ltd. All rights reserved.
General requirements to implement the personal dose equivalent Hp(10) in Brazil
NASA Astrophysics Data System (ADS)
Gomes Lopes, Amanda; Da Silva, Francisco Cesar Augusto
2018-03-01
To update the dosimetry quantity with the international community, Brazil is changing the Individual Dose (Hx) to the Personal Dose Equivalent Hp(10). A bibliographical survey on the technical and administrative requirements of nine countries that use Hp(10) was carried out to obtain the most relevant ones. All of them follow IEC and ISO guidelines for technical requirements, but administrative requirements change from country to country. Based on countries experiences, this paper presents a list of important general requirements to implement Hp(10) and to prepare the Brazilian requirements according to the international scientific community.
Diwakar, Lavanya; Cummins, Carole; Ryan, Ronan; Marshall, Tom; Roberts, Tracy
2017-04-01
Adrenaline auto-injectors (AAI) should be provided to individuals considered to be at high risk of anaphylaxis. There is some evidence that the rate of AAI prescription is increasing, but the true extent has not been previously quantified. To estimate the trends in annual GP-issued prescriptions for AAI among UK children between 2000 and 2012. Retrospective cohort study using data from primary care practices that contributed to The Health Improvement Network (THIN) database. Children and young people aged between 0-17 years of age with a prescription for AAIs were identified, and annual AAI device prescription rates were estimated using Stata (version 12). A total of 1.06 million UK children were identified, providing 5.1 million person years of follow-up data. Overall, 23 837 children were deemed high risk by their GPs, and were prescribed 98 737 AAI devices. This equates to 4.67 children (95% confidence interval [CI] = 4.66 to 4.69), and 19.4 (95% CI = 19.2 to 19.5) devices per 1000 person years. Between 2000 and 2012, there has been a 355% increase in the number of children prescribed devices, and a 506% increase in the total number of AAI devices prescribed per 1000 person years in the UK. The number of devices issued per high-risk child during this period has also increased by 33%. The number of children being prescribed AAI devices and the number of devices being prescribed in UK primary care between 2000 and 2012 has significantly increased. A discussion to promote rational prescribing of AAIs in the NHS is needed. © British Journal of General Practice 2017.
Inns, T; Lane, C; Peters, T; Dallman, T; Chatt, C; McFarland, N; Crook, P; Bishop, T; Edge, J; Hawker, J; Elson, R; Neal, K; Adak, G K; Cleary, P
2015-04-23
We report an outbreak of Salmonella Enteritidis phage type 14b (PT14b) in the United Kingdom (UK) between May and September 2014 where Public Health England launched an investigation to identify the source of infection and implement control measures. During the same period, outbreaks caused by a Salmonella Enteritidis strain with a specific multilocus variable-number tandem repeat analysis (MLVA) profile occurred in other European Union Member States. Isolates from a number of persons affected by the UK outbreak, who had initially been tested by MLVA also shared this particular profile. Cases were defined as any person infected with S. Enteritidis PT14b, resident in England or Wales and without history of travel outside of this geographical area during the incubation period, reported from 1 June 2014 onwards, with a MLVA profile of 2–11–9-7–4-3–2-8–9 or a single locus variant thereof. In total, 287 cases met the definition. Food traceback investigations in the UK and other affected European countries linked the outbreaks to chicken eggs from a German company. We undertook whole genome sequencing of isolates from UK and European cases, implicated UK premises, and German eggs: isolates were highly similar. Combined with food traceback information, this confirmed that the UK outbreak was also linked to a German producer.
Huntington, Susie; Thorne, Claire; Newell, Marie-Louise; Anderson, Jane; Taylor, Graham P; Pillay, Deenan; Hill, Teresa; Tookey, Pat A; Sabin, Caroline
2015-04-24
The objective of this study is to assess whether pregnancy is associated with an increased risk of liver enzyme elevation (LEE) and severe LEE in HIV-positive women on antiretroviral therapy (ART). Two observational studies: the UK Collaborative HIV Cohort (UK CHIC) study and the UK and Ireland National Study of HIV in Pregnancy and Childhood (NSHPC). Combined data from UK CHIC and NSHPC were used to identify factors associated with LEE (grade 1-4) and severe LEE (grade 3-4). Women starting ART in 2000-2012 were included irrespective of pregnancy status. Cox proportional hazards were used to assess fixed and time-dependent covariates including pregnancy status, CD4 cell count, drug regimen and hepatitis B virus/hepatitis C virus (HBV/HCV) coinfection. One-quarter (25.7%, 982/3815) of women were pregnant during follow-up, 14.2% (n = 541) when starting ART. The rate of LEE was 14.5/100 person-years in and 6.0/100 person-years outside of pregnancy. The rate of severe LEE was 3.9/100 person-years in and 0.6/100 person-years outside of pregnancy. The risk of LEE and severe LEE was increased during pregnancy [LEE: adjusted hazard ratio (aHR) 1.66 (1.31-2.09); severe LEE: aHR 3.57 (2.30-5.54)], including in secondary analyses excluding 541 women pregnant when starting ART. Other factors associated with LEE and severe LEE included lower CD4 cell count (<250 cells/μl), HBV/HCV coinfection and calendar year. Although few women developed severe LEE, this study provides further evidence that pregnancy is associated with an increased risk of LEE and severe LEE, reinforcing the need for regular monitoring of liver biomarkers during pregnancy.
Influenza immunisation: attitudes and beliefs of UK healthcare workers
Smedley, Julia; Poole, Jason; Waclawski, Eugene; Stevens, Anthony; Harrison, John; Watson, John; Hayward, Andrew; Coggon, David
2007-01-01
Aim To explore attitudes to influenza immunisation and rates of uptake among staff working in acute hospitals in the UK. Method A cross‐sectional survey of 11 670 healthcare workers in six UK hospitals was carried out using a postal questionnaire. Results Among 6302 responders (54% of those mailed), 19% had taken up influenza immunisation during winter 2002/3. Vaccination was well tolerated, with a low prevalence of side effects (13%) and associated time off work (2%). The majority of subjects who accepted vaccination (66%) were most strongly influenced by the personal benefits of protection against influenza. Prevention of sickness absence and protection of patients were the prime motivation for only 10% and 7% of subjects, respectively. Among 3967 who declined vaccination, the most common primary demotivators were concern about safety (31%) and efficacy (29%). 22% were most strongly deterred by lack of time to attend for vaccination. Free text answers indicated that 37% declined because of a perceived low ratio of personal benefits to adverse effects. Subjects said they would be persuaded to take up vaccination in future by easier access (36%), more information about personal benefit and risk (34%) and more information about effects on staff absence (24%). Conclusions These findings indicate that the uptake of influenza immunisation among UK healthcare workers remains low. There is some scope for increasing uptake by improving accessibility and encouragement from professional peers. However, the results suggest that perception of small personal benefit in relation to risk mitigates, importantly, against higher uptake of routine annual influenza vaccination. Thus, resource might better be allocated to ensuring efficient management in epidemic years. The effect of publicity about pandemic influenza on risk perception and vaccine uptake among healthcare workers during winter 2005/6 warrants further study. PMID:17182640
CHAIRMAN'S WELCOME MESSAGE Chairman's message
NASA Astrophysics Data System (ADS)
Oldham, Mark
2010-11-01
Every clinical physicist I have asked readily acknowledges the great desirability of a 3D dosimetry system for the verification of advanced radiation therapy treatments. An accurate and practical 3D dosimetry system would greatly strengthen the foundation of quality assurance in radiation therapy by enabling a rigorous and comprehensive whole system test. Such systems are now emerging, and the innovations and progress that led to them are remarkably captured in the proceedings of five prior DOSGEL conferences, the last three of which are freely available in the Journal of Physics: Conference Series. These meetings included a focus on the technical challenges of various approaches to 3D dosimetry. When considering plans for the present 6th meeting, the scientific committee recognized that the field has matured, and a broader focus was desirable, including a strengthening of the clinical and applications component, while preserving a strong technical component. There was also the desire to embrace a variety of other semi-3D techniques which have also recently emerged to implementation in the clinic. In accordance with these sentiments, the committee approved changing the name of the conference from the International Conference on Radiotherapy Gel Dosimetry (DOSGEL) to the International Conference on 3D Radiation Dosimetry (IC3DDose) and to the following objectives - Conference Objectives: 1. To provide a forum to discuss the latest research and developments in 3D and advanced radiation dosimetry. 2. To elevate the quality of radiation therapy treatments (quality assurance QA) through improved clinical dosimetry. 3. To explore the dosimetric challenges posed by modern radiation treatment techniques 4. To energize and diversify dosimetry research and clinical practice by encouraging interaction and synergy between advanced, 3D, and semi-3D dosimetry techniques The scientific program of the IC3DDose2010 meeting has been crafted to meet the objectives listed above, and we were fortunate that many leading speakers shared their experience and perspectives to help achieve these aims. On a more personal note it was a true pleasure to extend a warm welcome to all conference attendees. We have a very diverse group of clinical and research physicists from many parts of the world, and it is truly a pleasure to welcome you all. Finally I would like to acknowledge the many people who have made the meeting possible. Special thanks go to the Scientific Organizing Committee (listed opposite) who reviewed all the conference abstracts and participated in many planning conference calls, and meeting activities. The Local Organizing Committee shouldered a significant load finalizing the conference abstract book and ensuring smooth meeting logistics. We are also very grateful to our sponsors, both academic and industrial, whose support was vital to this meeting. Mark Oldham, PhD, FAAPM Associate Professor, Radiation Oncology and Biomedical Engineering, Duke University Medical Center, Durham, NC, USA mark.oldham@duke.edu Chairman
Learning the law: practical proposals for UK medical education.
Margetts, J K
2016-02-01
Ongoing serious breaches in medical professionalism might be avoided if UK doctors rethink their approach to law. UK medical education has a role in creating a climate of change by re-examining how law is taught to medical students. Adopting a more insightful approach in the UK to the impact of The Human Rights Act and learning to manipulate legal concepts, such as conflict of interest, need to be taught to medical students now if UK doctors are to manage complex decision-making in the NHS of the future. The literature is reviewed from a unique personal perspective of a doctor and lawyer, and practical proposals for developing medical education in law in the UK are suggested. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
ERIC Educational Resources Information Center
Beckley, Firle; Best, Wendy; Beeke, Suzanne
2017-01-01
Background: Communication strategy training (CST) is a recognized part of UK speech and language therapists' (SLTs) role when working with a person with aphasia. Multiple CST interventions have been published but, to date, there are no published studies exploring clinical practice in this area. Aims: To investigate UK SLTs' current CST practices.…
Individualized 131I-mIBG therapy in the management of refractory and relapsed neuroblastoma.
George, Sally L; Falzone, Nadia; Chittenden, Sarah; Kirk, Stephanie J; Lancaster, Donna; Vaidya, Sucheta J; Mandeville, Henry; Saran, Frank; Pearson, Andrew D J; Du, Yong; Meller, Simon T; Denis-Bacelar, Ana M; Flux, Glenn D
2016-05-01
Iodine-131-labelled meta-iodobenzylguanidine (I-mIBG) therapy is an established treatment modality for relapsed/refractory neuroblastoma, most frequently administered according to fixed or weight-based criteria. We evaluate response and toxicity following a dosimetry-based, individualized approach. A review of 44 treatments in 25 patients treated with I-mIBG therapy was performed. Patients received I-mIBG therapy following relapse (n=9), in refractory disease (n=12), or with surgically unresectable disease despite conventional treatment (n=4). Treatment schedule (including mIBG dose and number of administrations) was individualized according to the clinical status of the patient and dosimetry data from either a tracer study or previous administrations. Three-dimensional tumour dosimetry was also performed for eight patients. The mean administered activity was 11089±7222 MBq and the mean whole-body dose for a single administration was 1.79±0.57 Gy. Tumour-absorbed doses varied considerably (3.70±3.37 mGy/MBq). CTCAE grade 3/4 neutropenia was documented following 82% treatments and grade 3/4 thrombocytopenia following 71% treatments. Further acute toxicity was found in 49% of patients. All acute toxicities resolved with appropriate therapy. The overall response rate was 58% (complete or partial response), with a further 29% of patients having stable disease. A highly personalized approach combining patient-specific dosimetry and clinical judgement enables delivery of high activities that can be tolerated by patients, particularly with stem cell support. We report excellent response rates and acceptable toxicity following individualized I-mIBG therapy.
Dosimetry applications in GATE Monte Carlo toolkit.
Papadimitroulas, Panagiotis
2017-09-01
Monte Carlo (MC) simulations are a well-established method for studying physical processes in medical physics. The purpose of this review is to present GATE dosimetry applications on diagnostic and therapeutic simulated protocols. There is a significant need for accurate quantification of the absorbed dose in several specific applications such as preclinical and pediatric studies. GATE is an open-source MC toolkit for simulating imaging, radiotherapy (RT) and dosimetry applications in a user-friendly environment, which is well validated and widely accepted by the scientific community. In RT applications, during treatment planning, it is essential to accurately assess the deposited energy and the absorbed dose per tissue/organ of interest, as well as the local statistical uncertainty. Several types of realistic dosimetric applications are described including: molecular imaging, radio-immunotherapy, radiotherapy and brachytherapy. GATE has been efficiently used in several applications, such as Dose Point Kernels, S-values, Brachytherapy parameters, and has been compared against various MC codes which are considered as standard tools for decades. Furthermore, the presented studies show reliable modeling of particle beams when comparing experimental with simulated data. Examples of different dosimetric protocols are reported for individualized dosimetry and simulations combining imaging and therapy dose monitoring, with the use of modern computational phantoms. Personalization of medical protocols can be achieved by combining GATE MC simulations with anthropomorphic computational models and clinical anatomical data. This is a review study, covering several dosimetric applications of GATE, and the different tools used for modeling realistic clinical acquisitions with accurate dose assessment. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Musah, A; Gibson, J E; Leonardi-Bee, J; Cave, M R; Ander, E L; Bath-Hextall, F
2013-11-01
Basal cell carcinoma (BCC) is one of the most common types of nonmelanoma skin cancer affecting the white population; however, little is known about how the incidence varies across the U.K. To determine the variation in BCC throughout the U.K. Data from 2004 to 2010 were obtained from The Health Improvement Network database. European and world age-standardized incidence rates (EASRs and WASRs, respectively) were obtained for country-level estimates and levels of socioeconomic deprivation, while strategic health-authority-level estimates were directly age and sex standardized to the U.K. standard population. Incidence-rate ratios were estimated using multivariable Poisson regression models. The overall EASR and WASR of BCC in the U.K. were 98.6 per 100,000 person-years and 66.9 per 100,000 person-years, respectively. Regional-level incidence rates indicated a significant geographical variation in the distribution of BCC, which was more pronounced in the southern parts of the country. The South East Coast had the highest BCC rate followed by South Central, Wales and the South West. Incidence rates were substantially higher in the least deprived groups and we observed a trend of decreasing incidence with increasing levels of deprivation (P < 0.001). Finally, in terms of age groups, the largest annual increase was observed among those aged 30-49 years. Basal cell carcinoma is an increasing health problem in the U.K.; the southern regions of the U.K. and those in the least deprived groups had a higher incidence of BCC. Our findings indicate an increased incidence of BCC for younger age groups below 49 years. © 2013 British Association of Dermatologists.
The Cost of Ménière's Disease: A Novel Multisource Approach.
Tyrrell, Jessica; Whinney, David J; Taylor, Timothy
2016-01-01
To estimate the annual cost of Ménière's disease and the cost per person in the UK population and to investigate the direct and indirect costs of the condition. The authors utilized a multidata approach to provide the first estimate of the cost of Ménière's. Data from the UK Biobank (a study of 500,000 individuals collected between 2007 and 2012), the Hospital Episode Statistics (data on all hospital admissions in England from 2008 to 2012) and the UK Ménière's Society (2014) were used to estimate the cost of Ménière's. Cases were self-reported in the UK Biobank and UK Ménière's Society, within the Hospital Episode Statistics cases were clinician diagnosed. The authors estimated the direct and indirect costs of the condition, using count data to represent numbers of individuals reporting specific treatments, operations etc. and basic statistical analyses (χ tests, linear and logistic regression) to compare cases and controls in the UK Biobank. Ménière's was estimated to cost between £541.30 million and £608.70 million annually (equivalent to US $829.9 to $934.2 million), equating to £3,341 to £3,757 ($5112 to $5748) per person per annum. The indirect costs were substantial, with loss of earnings contributing to over £400 million per annum. For the first time, the authors were able to estimate the economic burden of Ménière's disease. In the UK, the annual cost of this condition is substantial. Further research is required to develop cost-effective treatments and management strategies for Ménière's to reduce the economic burden of the disease. These findings should be interpreted with caution due to the uncertainties inherent in the analysis.
Colgan, Fiona; Creegan, Chris; McKearney, Aidan; Wright, Tessa
2008-01-01
This article reports emerging findings from a qualitative research study about lesbian, gay and bisexual (LGB) people at work in the UK. The research focuses on the personal experiences and strategies of LGB people amidst changing organisational responses to sexuality within a new legal and political landscape following the introduction of the Employment Equality (Sexual Orientation) Regulations 2003. The article draws specifically on the perceptions of lesbian respondents about a range of issues concerning social inclusion and exclusion in the workplace including coming out at work, treatment by managers and colleagues, workplace and organisational culture and participation in LGBT groups and networks.
First person - Pawel Leznicki.
2018-05-16
First Person is a series of interviews with the first authors of a selection of papers published in Journal of Cell Science, helping early-career researchers promote themselves alongside their papers. Pawel Leznicki is the first author on 'Expansion of DUB functionality generated by alternative isoforms - USP35, a case study', published in Journal of Cell Science. Pawel conducted the research in this article while in Yogesh Kulathu's lab at the University of Dundee, UK. He is now a research associate in the lab of Stephen High at the University of Manchester, UK, investigating protein biogenesis processes and their quality control. © 2018. Published by The Company of Biologists Ltd.
Rehani, Madan M; Vano, Eliseo; Ciraj-Bjelac, Olivera; Kleiman, Norman J
2011-09-01
When this paper was about to go to press, the International Commission on Radiological Protection released a statement recommending a change in the threshold dose for the eye lens and dose limits for eye for occupationally exposed persons. It is clear that the earlier published threshold for radiation cataract is no longer valid. Epidemiological studies among Chernobyl clean-up workers, A bomb survivors, astronauts, residents of contaminated buildings, radiological technicians and recent surveys of staff in interventional rooms indicate that there is an increased incidence of lens opacities at doses below 1 Gy. Nevertheless, eye lens dosimetry is at a primitive stage and needs to be developed further. Despite uncertainties concerning dose threshold and dosimetry, it is possible to significantly reduce the risk of radiation cataract through the use of appropriate eye protection. By increasing awareness among those at risk and better adoption and increased usage of protective measures, radiation cataract can become preventable despite lowering of dose limits.
ERIC Educational Resources Information Center
Li, Zhen
2013-01-01
This paper presents a multiple ("n"?=?23), longitudinal case study of the construction of personal employability by Chinese students at a UK university. It draws on the work of Brown and Hesketh to frame notions of employability in order to understand how these students engage with the international and Chinese labour markets from their…
The Move to Mass Higher Education in the UK: Many Questions and Some Answers
ERIC Educational Resources Information Center
Mayhew, Ken; Deer, Cecile; Dua, Mehak
2004-01-01
This article describes the course and causes of the expansion of higher education in the UK since the 1960s. The number of university students from modest social backgrounds has increased, but they comprise much the same proportion of the university population as they did 40 years ago. Though personal rates of return from higher education are…
Embracing the UNCRC in Wales (UK): Policy, Pedagogy and Prejudices
ERIC Educational Resources Information Center
Lyle, Sue
2014-01-01
Most countries are signatories to the United Nations Convention on the Rights of the Child (UNCRC). In 1999, the Government of Wales was devolved from the UK, and in 2011 the "Children and Young Persons Rights Measure" put the UNCRC as the basis of all its work. Any programme introduced in schools should therefore promote the UNCRC. To…
ERIC Educational Resources Information Center
Baker, Fiona S.
2013-01-01
The revised UK Early Years Foundation Stage (EYFS) now places a stronger emphasis on personal, social and emotional development (PSED) as one of its three prime areas. PSED has three characteristics of learning: active learning, creating and thinking critically, and playing and exploring. These aspects of the revised EYFS closely align with the…
Homesickness among students in two cultures: antecedents and consequences.
Stroebe, Margaret; van Vliet, Tony; Hewstone, Miles; Willis, Hazel
2002-05-01
Review of the theoretical and empirical literature on homesickness showed that despite recent advances, scientific understanding of the impact on students of leaving home for college is still limited. Further empirical investigation using standardized measures, structural equation models and including additional mediating/moderating variables is needed. Two studies were thus conducted, one in the Netherlands, and one in the UK. Homesickness was investigated among recent-intake students, using a newly developed instrument, the Utrecht Homesickness Scale. Variables investigated in relationship to homesickness included depression, personality factors (self-liking, competence, self-esteem) and family situation (attachment to family). Homesickness was found to be a common though differentially prevalent phenomenon (approximately 50% in the Netherlands; 80% in the UK). Structural equation models showed that students missed family and friends and had difficulties adjusting to college life. These difficulties were associated with ruminations about home and loneliness, which themselves were associated with depression. There were differences in intensity (UK students were more homesick) and there were gender differences (UK females experienced more homesickness). Both the personality and family situation factors had an impact on homesickness. The results supported the conceptualization of homesickness as a 'mini-grief', to be viewed from theoretical perspectives in the field of loss and bereavement.
US line-ups outperform UK line-ups
Seale-Carlisle, Travis M.
2016-01-01
In the USA and the UK, many thousands of police suspects are identified by eyewitnesses every year. Unfortunately, many of those suspects are innocent, which becomes evident when they are exonerated by DNA testing, often after having been imprisoned for years. It is, therefore, imperative to use identification procedures that best enable eyewitnesses to discriminate innocent from guilty suspects. Although police investigators in both countries often administer line-up procedures, the details of how line-ups are presented are quite different and an important direct comparison has yet to be conducted. We investigated whether these two line-up procedures differ in terms of (i) discriminability (using receiver operating characteristic analysis) and (ii) reliability (using confidence–accuracy characteristic analysis). A total of 2249 participants watched a video of a crime and were later tested using either a six-person simultaneous photo line-up procedure (USA) or a nine-person sequential video line-up procedure (UK). US line-up procedure yielded significantly higher discriminability and significantly higher reliability. The results do not pinpoint the reason for the observed difference between the two procedures, but they do suggest that there is much room for improvement with the UK line-up. PMID:27703695
NASA Astrophysics Data System (ADS)
Bird, Adam; Murphy, Christophe; Dobson, Geoff
2017-09-01
RANKERN 16 is the latest version of the point-kernel gamma radiation transport Monte Carlo code from AMEC Foster Wheeler's ANSWERS Software Service. RANKERN is well established in the UK shielding community for radiation shielding and dosimetry assessments. Many important developments have been made available to users in this latest release of RANKERN. The existing general 3D geometry capability has been extended to include import of CAD files in the IGES format providing efficient full CAD modelling capability without geometric approximation. Import of tetrahedral mesh and polygon surface formats has also been provided. An efficient voxel geometry type has been added suitable for representing CT data. There have been numerous input syntax enhancements and an extended actinide gamma source library. This paper describes some of the new features and compares the performance of the new geometry capabilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The study of the toxicity of radium and radium decay products was continued. Special emphasis was placed on the acquisition of data on patients selected by record of exposure. Data are tabulated on the radium body burden of about 40 individuals. About half the measurements were made on living persons and about half on tooth or bone specimens. Case history summaries and all available medical data are summarized for persons under study. An investigation of the gamma shielding properties of dunite was continued. Design modifications and calibration of radiation detection instruments are discussed. (For preceding period see AECU-3504.) (C.H.)
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minsky, D. M.; Kreiner, A. J.; ECyT, UNSAM, M. de Irigoyen 3100
2010-08-04
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the {sup 10}B body distribution which, in turn, is governed by the tumor specificity of the {sup 10}B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction {sup 10}B(n,{alpha}){sup 7}Li accounts for about 80 % of the total dose in a tumor with 40 ppm in {sup 10}B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical datamore » and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from {sup 7}Li. For this purpose we designed, built and tested a prototype based on LaBr{sub 3}(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.« less
An Examination of the First Oxford House in the UK: A Preliminary Investigation
Majer, John M.; Beers, Kim; Jason, Leonard A.
2014-01-01
An exploratory investigation was conducted to examine the implementation of the first self-run, communal-living setting based on the Oxford House model, in the United Kingdom (UK). A cross-sectional, mixed methods design was used to examine the Oxford House model’s total abstinence approach to recovery from substance use disorders among residents (n = 7) living in the first Oxford House established in the UK. Several measures commonly used in addiction research and personal narratives were used to assess residents’ response to Oxford House living. Findings suggest that the Oxford House model is a post-treatment intervention that meets the needs of individuals seeking an abstinence-based recovery from alcohol and/or drug dependence in the UK. PMID:25368450
2010 Annual Health Physics Report for the HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, Radoslav
2011-05-16
During the 2010 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2010, there were 141 person-trips that required dose monitoring of the U.S. monitors. Of the 141 person-trips, 129 person-trips were Special Monitoring Visits (SMVs) and 12 person-trips were Transparency Monitoring Office (TMO) trips. In 8 of these TMO trips the TMO monitors participated also in the UEIE SMVs and in 2 TMOmore » trips the TMO monitors participated in UEIE and MPA SMVs. There were three monitoring visits (source changes) that were back-to-back SMVs with a total of 25 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors.« less
Mathematics Is?--A Journey Completed
ERIC Educational Resources Information Center
Turner, Laura
2011-01-01
In this article, the author explores her personal views on mathematics and how she solves problems. She experiences some personal revelations while attending a "Mathsjam". Organised by some of the more prominent names in the popularisation of mathematics, "Mathsjam" was billed as the UK's first Gathering for Gardner, an event…
ERIC Educational Resources Information Center
Abbott, David; Marriott, Anna
2013-01-01
In the UK, policy on adult social care places an emphasis on maximising choice and control for service users, including people with learning disabilities. The shift from the provision of organised services for groups of people to offering individual and personal budgets and pots of money for people to buy their own services has major implications…
ERIC Educational Resources Information Center
Chadderton, Charlotte
2012-01-01
Since September 11th 2001, and the London bombings of July 2005, the "war on terror" has led to the subjection of populations to new regimes of control and reinforced state sovereignty. This involves, in countries such as the UK and the US, the limiting of personal freedoms, increased regulation of immigration and constant surveillance,…
A Teaching Elixir, Learning Chimera or Just Fool's Gold? Do Learning Styles Matter?
ERIC Educational Resources Information Center
Rayner, Steve
2007-01-01
The idea of a personal style in learning has grown during the past decade to dominate teacher discourse in the UK. The theory supporting this idea is work in understanding cognitive and learning style. A recent review of learning styles for the Learning and Skills Development Agency in the UK has been widely publicised and is deeply critical of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, A L; University of Surrey, Guildford, Surrey; Bradley, D A
Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy.more » Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pena, E; Caprile, P; Sanchez-Nieto, B
Purpose: The thermoluminiscense dosimeters (TLDs) are widely used in personal and clinical dosimetry due to its small size, good sensitivity and tissue equivalence, among other advantages. This study presents the characterization of Lithium Fluoride based TLDs, in terms of their absorbed dose response to successive irradiation cycles in a broad range of beam energies, measured under reference conditions. Methods: Four types of Harshaw TLD chips were used: TLD-100, TLD-600 TLD-700 and 100-H. They were irradiated with 10 photon beams of different energy spectrums, from 28 kVp to 18MV (in 30 consecutive cycles for 6 and 18 MV). Results: It wasmore » found that the response of the dosimetric system was stabilized (less than ±3%) after 10 cycles for TLD-600 and TLD-700. In the case of TLD-100 and TLD-100H this dependence was not observed. A decreased response to increasing beam energy in terms of absorbed dose to water was observed, as expected, except for TLD-100H which showed the opposite behavior. The less energy dependent detector was the TLD-100H exhibiting a maximum deviation of 12%. The highest variation observed was 33% for TLD-100. The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy. Conclusion: The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy.« less
Budzanowski, Maciej; Kopeć, Renata; Obryk, Barbara; Olko, Paweł
2011-03-01
Individual dosimetry service based on thermoluminescence (TLD) detectors has started its activity at the Institute of Nuclear Physics (IFJ) in Krakow in 1965. In 2002, the new Laboratory of Individual and Environment Dosimetry (Polish acronym LADIS) was established and underwent the accreditation according to the EN-PN-ISO/IEC 17025 standard. Nowadays, the service is based on the worldwide known standard thermoluminescent detectors MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P), developed at IFJ, processed in automatic thermoluminescent DOSACUS or RE2000 (Rados Oy, Finland) readers. Laboratory provides individual monitoring in terms of personal dose equivalent H(p)(10) and H(p)(0.07) in photon and neutron fields, over the range from 0.1 mSv to 1 Sv, and environmental dosimetry in terms of air kerma K(a) over the range from 30 μGy to 1 Gy and also ambient dose equivalent H*(10) over the range from 30 μSv to 1 Sv. Dosimetric service is currently performed for ca. 3200 institutions from Poland and abroad, monitored on quarterly and monthly basis. The goal of this paper is to identify the main activities leading to the highest radiation exposures in Poland. The paper presents the results of statistical evaluation of ∼ 100,000 quarterly H(p)(10) and K(a) measurements performed between 2002 and 2009. Sixty-five per cent up to 90 % of all individual doses in Poland are on the level of natural radiation background. The dose levels between 0.1 and 5 mSv per quarter are the most frequent in nuclear medicine, veterinary and industrial radiography sectors.
The work programme of EURADOS on internal and external dosimetry.
Rühm, W; Bottollier-Depois, J F; Gilvin, P; Harrison, R; Knežević, Ž; Lopez, M A; Tanner, R; Vargas, A; Woda, C
2018-01-01
Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .
ERIC Educational Resources Information Center
Saricaoglu, Halim; Arslan, Coskun
2013-01-01
The purpose of this study is to investigate the correlation between psychological well-being, personal traits and self-compassion levels, and to find out whether personal traits and self-compassion level significantly predict psychological well-being. The study sample is composed of 232 (36.5%) students from Education Faculty of Selçuk University,…
Professional conduct among registered nurses in the use of online social networking sites.
Levati, Sara
2014-10-01
To explore the use of Facebook by Registered Nurses (RNs) in Italy and the United Kingdom (UK), focusing on the disclosure of personal and professional information. The use of online social network sites among medical students and doctors is posing new ethical challenges to the profession. To date, little research has explored the use of online social networking sites among nurses. A cross-national survey. Data were assessed on 124 nurses' profile pages, readily available without viewing restrictions. Content analysis and inferential statistics were undertaken to describe usage and identify similarities and differences between the two country-groups of nurses. Data were collected between December 2011-January 2012. Overall, UK and Italian RNs showed a similar use of the online platform, tending to disclose personal pictures, home town and current home location, as well as updates and comments related to personal and work-related activities. A statistically significant higher proportion of nurses in Italy disclosed their sexual orientation. In both groups, a few cases were observed of potentially unprofessional content in relation to the use of alcohol, nudity and material of a salacious nature. Although most of the UK and Italy RNs appear to be aware of the risks posed by their online exposure, their online activity indicates the blurring of their personal and professional lives; this is posing new ethical, legal and professional challenges to members of the nursing profession. Further research and debate is encouraged at national and international level. © 2014 John Wiley & Sons Ltd.
1990-04-01
and a stepped lead flattening filter. The electron energy used for these studies was 13 MeV. Dosimetry was performed by the Health Physics Division...VolI LJSAFSAPA-TR-90-4 AD-A222 722 SURVIVAL OF CHINESE HAMSTER OVARY CELLS FOLLOWING ULTRAHIGH DOSE RATE ELECTRON AND BREMISSTRAHLUNG RADIATION...Include Security ;a!. iatcn) Survival of Chinese Hamster Ovary Cells Following Ultrahigh Dose Rate Electron and Bremsstrahlung Radiation 12 PERSONAL
Incidence of shoulder dislocations in the UK, 1995–2015: a population-based cohort study
Judge, Andrew; Delmestri, Antonella; Edwards, Katherine; Arden, Nigel K; Prieto-Alhambra, Daniel; Holt, Tim A; Pinedo-Villanueva, Rafael A; Hopewell, Sally; Lamb, Sarah E; Rangan, Amar; Carr, Andrew J; Collins, Gary S; Rees, Jonathan L
2017-01-01
Objective This cohort study evaluates the unknown age-specific and gender-specific incidence of primary shoulder dislocations in the UK. Setting UK primary care data from the Clinical Practice Research Datalink (CPRD) were used to identify patients aged 16–70 years with a shoulder dislocation during 1995–2015. Coding of primary shoulder dislocations was validated using the CPRD general practitioner questionnaire service. Participants A cohort of 16 763 patients with shoulder dislocation aged 16–70 years during 1995–2015 were identified. Primary outcome measure Incidence rates per 100 000 person-years and 95% CIs were calculated. Results Correct coding of shoulder dislocation within CPRD was 89% (95% CI 83% to 95%), and confirmation that the dislocation was a ‘primary’ was 76% (95% CI 67% to 85%). Seventy-two percent of shoulder dislocations occurred in men. The overall incidence rate in men was 40.4 per 100 000 person-years (95% CI 40.4 to 40.4), and in women was 15.5 per 100 000 person-years (95% CI 15.5 to 15.5). The highest incidence was observed in men aged 16–20 years (80.5 per 100 000 person-years; 95% CI 80.5 to 80.6). Incidence in women increased with age to a peak of 28.6 per 100 000 person-years among those aged 61–70 years. Conclusions This is the first time the incidence of shoulder dislocations has been studied using primary care data from a national database, and the first time the results for the UK have been produced. While most primary dislocations occurred in young men, an unexpected finding was that the incidence increased in women aged over 50 years, but not in men. The reasons for this are unknown. Further work is commissioned by the National Institute for Health Research to examine treatments and predictors for recurrent shoulder dislocation. Study registration The design of this study was approved by the Independent Scientific Advisory Committee (15_260) for the Medicines & Healthcare products Regulatory Agency. PMID:29138197
Elder, Alexander; Paterson, Caron
2006-12-01
To review the literature on sharps injuries and occupational bloodborne virus transmission in health care in the UK and the worldwide evidence for injury prevention of sharps safety devices. Literature review by online database and Internet resource search. Twenty-four relevant publications were identified regarding UK reported sharps injury rates. UK studies showed as much as a 10-fold difference between injuries reported through standard reporting systems (0.78-5.15 per 100 person-years) and rates estimated from retrospective questionnaires of clinical populations (30-284 per 100 person-years). National surveillance data from England, Wales and Northern Ireland gives a rate of 1.43 known hepatitis C virus or human immunodeficiency virus (HIV) transmissions to health care workers per annum. When extrapolated, this suggests an approximate rate of 0.009 such viral transmissions per 1000 hospital beds per annum. Risk of infection from sources with no risk factors is extremely small (less than one in one million for HIV transmission based on Scottish data). Thirty-one studies on the efficacy of sharps safety devices showed evidence of a reduction in injuries, with the greatest reductions achieved by blunt suture needles and safety cannulae. Although injuries remain common, confirmed viral transmission in the UK has been relatively rare. The degree of under-reporting of sharps injuries may be as much as 10-fold. Safety-engineered devices are likely to be effective at injury reduction.
Firefighter noise exposure during training activities and general equipment use.
Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J
2013-01-01
Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.
Macfarlane, Gary J; Beasley, Marcus; Smith, Blair H; Jones, Gareth T; Macfarlane, Tatiana V
2015-01-01
Introduction: Biobank-type studies are typically large but have very low participation rates. It has been suggested that these studies may provide biased estimates of prevalence but are likely to provide valid estimates of association. We test these hypotheses using data collected on pain in a large Biobank study in the United Kingdom. Methods: UK Biobank recruited 503,325 persons aged 40–69 years (participation rate 5.5%). Participants completed questionnaires, including pain, lifestyle and environment factors. As a comparison, we used both a large population study of pain (MUSICIAN: n = 8847, aged: 40–69 years) conducted 2008–2009 and the National Child Development study (NCDS) which recruited all persons in Great Britain born during one week of 1958 and followed them up at age 44 years (n = 9377). Results: ‘Any pain’ (UK Biobank 61.0%; MUSICIAN 63.9%), chronic pain (42.9%, 52.2%) and site-specific musculoskeletal pain (back 26.2%, 29.7%; shoulder/neck 23.3%, 25.3%) were generally similar in UK Biobank and MUSICIAN. The prevalence of chronic pain and most regional musculoskeletal pains in UK Biobank were all within 2% of that in NCDS. Conclusion: UK Biobank has provided estimates of the prevalence of pain which are similar to those from previous large-scale studies, although a formal comparison of the estimates cannot be made. It has also confirmed known associations with the reporting of pain. Despite its very low participation rate, such a study provides the opportunity to investigate novel exposure–pain relationships and investigate rarer exposures and characteristics to further our knowledge of the epidemiology of pain. PMID:26526341
Valletta, J J; Chipperfield, A J; Clough, G F; Byrne, C D
2012-06-01
Constant moderate intensity physical exertion in humid environments at altitude poses a considerable challenge to maintaining euglycaemia with Type 1 diabetes. Blood glucose concentrations and energy expenditure were continuously recorded in a person trekking at altitude in a tropical climate to quantify changes in glucose concentrations in relation to energy expenditure. Blood glucose concentrations and energy expenditure were continuously monitored with a Guardian® real-time continuous glucose monitoring system (CGMS) and a SenseWear® Pro3 armband (BodyMedia Inc., USA), in a 27-year-old woman with Type 1 diabetes, during her climb up Mount Kinabalu in Borneo (c. 4095 m). Comparative control data from the same person was collected in the UK (temperate climate at sea level) and Singapore (tropical climate at sea level). Maximum physical effort during the climb was < 60% VO(2MAX) (maximal oxygen consumption). Mean daily calorific intakes were 2300 kcal (UK), 2370 kcal (Singapore) and 2274 kcal (Mount Kinabalu), and mean daily insulin doses were 54 U (UK), 40 U (Singapore) and 47 U (Mount Kinabalu). Despite markedly increased energy expenditure during the climb [4202 kcal (Mount Kinabalu) vs. 2948 kcal (UK) and 2662 kcal (Singapore)], mean blood glucose was considerably higher during the trek up Mount Kinabalu [13.2 ± 5.9 mmol/l, vs. 7.9 ± 3.8 mmol/l (UK) and 8.6 ± 4.0 mmol/l (Singapore)]. Marked unexpected hyperglycaemia occurred while trekking on Mount Kinabalu, despite similar calorie consumption and insulin doses to control conditions. Because of the risk of unexpected hyperglycaemia in these conditions, we recommend that patients embarking on similar activity holidays undertake frequent blood glucose monitoring. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.
ERIC Educational Resources Information Center
Owen, Nathaniel; Fox, Alison; Bird, Terese
2016-01-01
This paper documents the creation, implementation and analysis of a survey instrument designed to reveal patterns of use and attitudes towards the value of social media by UK teachers. The study was motivated to discover which teachers use social media professionally, how they use it (both personally and professionally) and attitudes to social…
Assessing the dosimetric and geometric accuracy of stereotactic radiosurgery
NASA Astrophysics Data System (ADS)
Dimitriadis, Alexis
Stereotactic radiosurgery (SRS) is a non-invasive treatment predominantly used for the management of malignant and benign brain tumours. The treatment can be delivered by various platforms in a single fraction where a high dose of radiation is delivered to the target whilst the surrounding healthy tissue is spared. This requires a high degree of accuracy in terms of the dose level delivered but also in terms of geometric precision. The purpose of this work was to identify the variations of SRS practice in the UK and develop a novel method compatible with all practices, capable of assessing the accuracy of delivery. The motivation behind this effort was to contribute to safety in SRS delivery, provide confidence through a quality assurance audit and form a basis to support standardisation in SRS. A national survey was performed to investigate SRS practices in the UK and to help guide the methodology of this thesis. This resulted to the development of a method for an end-to-end audit of SRS. This was based on an anthropomorphic head phantom with a medium sized target located centrally in the brain, in close proximity to the brainstem. This realistic patient scenario was presented to all 26 radiosurgery centres in the UK who were asked to treat it with SRS. The dose delivered was assessed using two novel commercially available radiation detectors, a plastic scintillator and radiochromic film. These detectors were characterised for measuring the dose delivered in SRS. Another established dosimetry system, alanine, was also used alongside these detectors to assess the accuracy of each delivery. The results allowed the assessment of SRS practices in the UK and the comparison of all centres that participated in the audit. The results were also used to evaluate the performance of the dosimeters used for the purposes of quality assurance measurements and audit.
Diez, P; Hoskin, P J; Aird, E G A
2007-10-01
This questionnaire forms the basis of the quality assurance (QA) programme for the UK randomized Phase III study of the Stanford V regimen versus ABVD for treatment of advanced Hodgkin's disease to assess differences between participating centres in treatment planning and delivery of involved-field radiotherapy for Hodgkin's lymphoma The questionnaire, which was circulated amongst 42 participating centres, consisted of seven sections: target volume definition and dose prescription; critical structures; patient positioning and irradiation techniques; planning; dose calculation; verification; and future developments The results are based on 25 responses. One-third plan using CT alone, one-third use solely the simulator and the rest individualize, depending on disease site. Eleven centres determine a dose distribution for each patient. Technique depends on disease site and whether CT or simulator planning is employed. Most departments apply isocentric techniques and use immobilization and customized shielding. In vivo dosimetry is performed in 7 centres and treatment verification occurs in 24 hospitals. In conclusion, the planning and delivery of treatment for lymphoma patients varies across the country. Conventional planning is still widespread but most centres are moving to CT-based planning and virtual simulation with extended use of immobilization, customized shielding and compensation.
Wenborn, Jennifer; Hynes, Sinéad; Moniz-Cook, Esme; Mountain, Gail; Poland, Fiona; King, Michael; Omar, Rumana; Morris, Steven; Vernooij-Dassen, Myrra; Challis, David; Michie, Susan; Russell, Ian; Sackley, Catherine; Graff, Maud; O'Keeffe, Aidan; Crellin, Nadia; Orrell, Martin
2016-02-03
A community-based occupational therapy intervention for people with mild to moderate dementia and their family carers (Community Occupational Therapy in Dementia (COTiD)) was found clinically and cost effective in the Netherlands but not in Germany. This highlights the need to adapt and implement complex interventions to specific national contexts. The current trial aims to evaluate the United Kingdom-adapted occupational therapy intervention for people with mild to moderate dementia and their family carers living in the community (COTiD-UK) compared with treatment as usual. This study is a multi-centre, parallel-group, pragmatic randomised trial with internal pilot. We aim to allocate 480 pairs, with each pair comprising a person with mild to moderate dementia and a family carer, who provides at least 4 hours of practical support per week, at random between COTiD-UK and treatment as usual. We shall assess participants at baseline, 12 and 26 weeks, and by telephone at 52 and 78 weeks (first 40% of recruits only) after randomisation. The primary outcome measure is the Bristol Activities of Daily Living Scale (BADLS) at 26 weeks. Secondary outcome measures will include quality of life, mood, and resource use. To assess intervention delivery, and client experience, we shall collect qualitative data via audio recordings of COTiD-UK sessions and conduct semi-structured interviews with pairs and occupational therapists. COTiD-UK is an evidence-based person-centred intervention that reflects the current priority to enable people with dementia to remain in their own homes by improving their capabilities whilst reducing carer burden. If COTiD-UK is clinically and cost effective, this has major implications for the future delivery of dementia services across the UK. Current Controlled Trials ISRCTN10748953 Date of registration: 18 September 2014.
Bowen, Matt Laurence
2016-12-01
There is evidence that people with personality disorder are stigmatized within healthcare settings; however, little is known about the role that the media has played in the wider processes of stigmatization. This research examines the degree to which the popular press in the UK have established a link between personality disorder and homicide, and the impact this may have had on the processes of stigmatization. Using a content analysis approach, it was identified that there were 552 articles in the popular press, between 2001 and 2012, that made reference to personality disorder and 42% of those articles established a link with homicide. Comparison between two time periods, 2001-2006 and 2007-2012, identified that there was a significant reduction in the proportion of homicide articles (Pearson χ 2 (5, n = 552) = 5.64, P > .05), however, the effect size of this change was only small. These findings suggest that the press may have contributed to the processes of stigmatization, and may have encouraged the general public to hold prejudicial attitudes towards people with a diagnosis of personality disorder. © 2016 Australian College of Mental Health Nurses Inc.
Nanoparticle-based photodynamic therapy on non-melanoma skin cancer
NASA Astrophysics Data System (ADS)
Fanjul-Vélez, F.; Arce-Diego, J. L.
2018-02-01
There are several advantages of Photodynamic Therapy (PDT) for nonmelanoma skin cancer treatment compared to conventional treatment techniques such as surgery, radiotherapy or chemotherapy. Among these advantages its noninvasive nature, the use of non ionizing radiation and its high selectivity can be mentioned. Despite all these advantages, the therapeutic efficiency of the current clinical protocol is not complete in all the patients and depends on the type of pathology. An adequate dosimetry is needed in order to personalize the protocol. There are strategies that try to overcome the current PDT shortcomings, such as the improvement of the photosensitizer accumulation in the target tissue, optical radiation distribution optimization or photochemical reactions maximization. These strategies can be further complemented by the use of nanostructures with conventional PDT. Customized dosimetry for nanoparticle-based PDT requires models in order to adjust parameters of different nature to get an optimal tumor removal. In this work, a predictive model of nanoparticle-based PDT is proposed and analyzed. Dosimetry in nanoparticle-based PDT is going to be influenced by photosensitizer-nanoparticle distribution in the malignant tissue, its influence in the optical radiation distribution and the subsequent photochemical reactions. Nanoparticles are considered as photosensitizer carriers on several types of non-melanoma skin cancer. Shielding effects are taken into account. The results allow to compare the estimated treatment outcome with and without nanoparticles.
ERIC Educational Resources Information Center
International Federation of Library Associations, The Hague (Netherlands).
Eleven of the 15 papers in this collection discuss library services for disadvantaged persons; the remaining four papers are concerned with services to multicultural populations. The papers from the Section of Libraries Serving Disadvantaged Persons appear first in this list: (1) "The Development and Future of Easy Readers for Adults in the UK"…
1994-10-01
dosimetry services using thermoluminescent dosimeters ( TLDs ) to meet 10 CFR 19, 20, 30-36, 40 and 70; to proNide dosimetry service for environmental...USAF Personnel Dosimetry Branch. Once it is determined that area or external dosimetry is necessary, request the number of TLDs required by FAX or letter... dosimetry , Request TLDs 2 - 4 weeks in advance and always designate a control badge. The Radiation Dosimetry Branch thanks you in advance for doing everything
AIDS: a challenge for the public health.
Acheson, E D
1986-03-22
While the number of cases of acquired immunodeficiency syndrome (AIDS) has been increasing worldwide, the incidence in the United Kingdom (UK) is substantially lower than in the United States (US) and several other European countries. In the UK and US, the infection is confined largely to homosexual and bisexual men, persons who abuse drugs by injection, hemophiliacs, and sexual partners of members of these groups, including heterosexual men and women. Public education must focus on methods of transmission and control of the disease. The efficacy of testing for antibodies to the HTLV-III infection is questionable because there is no cure at present. Issues of confidentiality and denial of insurance or other support to persons who test positive must be considered.
ERIC Educational Resources Information Center
Harris, Belinda
2008-01-01
Schools in the UK and beyond continue to experience the damaging effects of "top down," "one size fits all" "outcome-based" educational reforms. Educators struggle to meet the dual demands of a punishing performativity- and accountability-driven regime alongside the personal, social, emotional and learning needs of…
The subject paper describes a procedure for adjusting a risk model based upon a measure of personal exposure (the "UK personal exposure model") in order to attribute an expected rate of gastroenteritis among a group of swimmers to a mean recreational water quality value (enteroco...
Personal Epistemologies of Statisticians in Academia: An Exploratory Study
ERIC Educational Resources Information Center
Diamond, Aurel H.; Stylianides, Andreas J.
2017-01-01
In this exploratory study, we investigated the personal epistemologies of statisticians in academia with the aim of offering some insight into what might be an availing epistemology for learning statistics. Findings from in-depth, semi-structured interviews with six academics in the UK currently researching within the field of statistics showed…
Learning and Personality on Study Tours Abroad
ERIC Educational Resources Information Center
Miao, Shin Yu; Harris, Roger
2012-01-01
Study tours abroad are important arenas for post-compulsory education. This paper focuses on how personality affects students' learning on study tours abroad. The research involved 66 learners from one higher education institution in Taiwan on tours to the UK, the USA and Australia. Data were gathered using questionnaires and learning journals,…
Thyroid cancer following scalp irradiation. [X radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Modan, B.; Ron, E.; Werner, A.
1977-05-25
A sixfold increase in the risk of thyroid cancer was observed among 10,902 persons irradiated for scalp tinea in childhood as compared to two matched control groups. The dosimetry studies demonstrated that the original mean dose given to the thyroid was less than 9 rads, yielding a risk of 6.3/10/sup 6//year. This carcinogenic effect of low-level radiation must be considered in the planning of safety measures against potential public health hazards.
Dosimetry-based treatment for Graves' disease.
Hyer, Steve L; Pratt, Brenda; Gray, Matthew; Chittenden, Sarah; Du, Yong; Harmer, Clive L; Flux, Glenn D
2018-06-01
The aim of this retrospective study was to assess the long-term outcome of a personalized dosimetry approach in Graves' disease aiming to render patients euthyroid from a planned thyroid absorbed dose of 60 Gy. A total of 284 patients with Graves' disease were followed prospectively following administration of radioiodine calculated to deliver an absorbed dose of 60 Gy. Patients with cardiac disease were excluded. Outcomes were analysed at yearly intervals for up to 10 years with a median follow-up of 37.5 months. A single radioiodine administration was sufficient to render a patient either euthyroid or hypothyroid in 175 (62%) patients, the remainder requiring further radioiodine. The median radioactivity required to deliver 60 Gy was 77 MBq. Less than 2% patients required 400-600 MBq, the standard activity administered in many centres. In the cohort receiving a single administration, 38, 32 and 26% were euthyroid on no specific thyroid medication at 3, 5 and 10 years, respectively. Larger thyroid volumes were associated with the need for further therapy. The presence of nodules on ultrasonography did not adversely affect treatment outcome. A personalized dosimetric approach delayed the long-term onset of hypothyroidism in 26% of patients. This was achieved using much lower administered activities than currently recommended. Future studies will aim to identify those patients who would benefit most from this approach.
Radiation-Induced Second Cancer Risk Estimates From Radionuclide Therapy
NASA Astrophysics Data System (ADS)
Bednarz, Bryan; Besemer, Abigail
2017-09-01
The use of radionuclide therapy in the clinical setting is expected to increase significantly over the next decade. There is an important need to understand the radiation-induced second cancer risk associated with these procedures. In this study the radiation-induced cancer risk in five radionuclide therapy patients was investigated. These patients underwent serial SPECT imaging scans following injection as part of a clinical trial testing the efficacy of a 131Iodine-labeled radiopharmaceutical. Using these datasets the committed absorbed doses to multiple sensitive structures were calculated using RAPID, which is a novel Monte Carlo-based 3D dosimetry platform developed for personalized dosimetry. The excess relative risk (ERR) for radiation-induced cancer in these structures was then derived from these dose estimates following the recommendations set forth in the BEIR VII report. The radiation-induced leukemia ERR was highest among all sites considered reaching a maximum value of approximately 4.5. The radiation-induced cancer risk in the kidneys, liver and spleen ranged between 0.3 and 1.3. The lifetime attributable risks (LARs) were also calculated, which ranged from 30 to 1700 cancers per 100,000 persons and were highest for leukemia and the liver for both males and females followed by radiation-induced spleen and kidney cancer. The risks associated with radionuclide therapy are similar to the risk associated with external beam radiation therapy.
Phantom-derived estimation of effective dose equivalent from X rays with and without a lead apron.
Mateya, C F; Claycamp, H G
1997-06-01
Organ dose equivalents were measured in a humanoid phantom in order to estimate effective dose equivalent (H(E)) and effective dose (E) from low-energy x rays and in the presence or absence of a protective lead apron. Plane-parallel irradiation conditions were approximated using direct x-ray beams of 76 and 104 kVp and resulting dosimetry data was adjusted to model exposures conditions in fluoroscopy settings. Values of H(E) and E estimated under-shielded conditions were compared to the results of several recent studies that used combinations of measured and calculated dosimetry to model exposures to radiologists. While the estimates of H(E) and E without the lead apron were within 0.2 to 20% of expected values, estimates based on personal monitors worn at the (phantom) waist (underneath the apron) underestimated either H(E) or E while monitors placed at the neck (above the apron) significantly overestimated both quantities. Also, the experimentally determined H(E) and E were 1.4 to 3.3 times greater than might be estimated using recently reported "two-monitor" algorithms for the estimation of effective dose quantities. The results suggest that accurate estimation of either H(E) or E from personal monitors under conditions of partial body exposures remains problematic and is likely to require the use of multiple monitors.
NASA Astrophysics Data System (ADS)
Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.
2017-06-01
The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.
Embodiment of discrimination and overseas nurses' career progression.
Larsen, John Aggergaard
2007-12-01
To examine empirically and in-depth how discriminatory attitudes and practices are experienced by overseas nurses and how the discrimination may affect their well-being and career progression and, furthermore, to apply the theoretical perspective of embodiment in understanding these processes. The UK healthcare sector has, in recent years, relied on overseas-trained professionals to fill up vacancies in nursing and other professions. Research shows that overseas nurses claim that their UK colleagues, managers and patients express discriminatory, racist and xenophobic attitudes. The paper provides an existential phenomenological analysis of in-depth interviews with two overseas nurses. The data are drawn from a study of overseas-trained healthcare workers' experiences working and living in the UK. The two cases have been purposively selected to provide an illumination and discussion of personal experiences with discrimination, how individuals may respond to these and how their professional career is affected. Discrimination towards migrant workers may, at times, be experienced as 'blatant racism' or, in more subtle forms, as 'aversive racism'. It is demonstrated how such discrimination may impact on the afflicted person's sense of self, suggesting a theoretical model of the embodiment of discrimination. Discrimination not only works at an interpersonal and institutional level, but is a form of 'symbolic violence' that may be internalized to affect the person's 'habitus'; it can be resisted through meaning-making activity that explains and hence objectifies and embodies the experience in a way that allows individuals to positively influence their situation through agency. This article details how social and institutionalized discrimination in the UK healthcare sector may be internalized by overseas workers and affects their professional careers. The study allows a theoretical reflection on the damage inflicted by discrimination, and it may contribute to the eradication of discriminatory practices and the development of necessary support and monitoring mechanisms.
Optics Education In The United Kingdom
NASA Astrophysics Data System (ADS)
Smith, Robin
1989-04-01
In this paper we review optics teaching at the postgraduate MSc level in the UK. We precede this with some personal comments based on 20 years teaching experience in the Applied Optics MSc Course at Imperial College, London. As one might expect much of the MSc teaching in the UK is based at centres of research in optics. There are other centres of research where "modern" optics is only taught in undergraduate (BSc) option courses.
2002-11-01
of CaF2:Mn and A120 3 TLDs for gamma-ray dosimetry ). In addition, DRDC Ottawa has recently substantially expanded its efforts in radiation dosimetry ...use of any real- time electronic dosimeter. Foils have long been proposed and used for criticality dosimetry (as well as for general monitoring of...ray Dosimetry DRDC Ottawa offers a number (over five) of various thermoluminescence dosimetry ( TLD ) systems. The choice of any particular TLD depends
The privacy-reciprocity connection in biobanking: comparing German with UK strategies.
Hobbs, A; Starkbaum, J; Gottweis, U; Wichmann, H E; Gottweis, H
2012-01-01
In recent years, the adequacy of the 'gift' model of research participation has been increasingly questioned. This study used focus groups to explore how potential and actual participants of biobanks in the UK and Germany negotiate the relationship between concerns over privacy protection, reciprocity and benefit sharing. In Germany, 15 focus groups (n = 151) were conducted: 11 general public groups (n = 116) and 4 with former cohort study participants including the KORA and the Popgen cohort study (n = 35). In the UK, 9 focus groups (n = 61) were conducted: 4 general public groups (n = 33) and 5 with UK Biobank and European Huntington's Disease (Euro-HD) Registry biorepository participants (n = 28). Forms of reciprocity were found to partially mitigate potential and actual biobank participants' concerns over personal privacy risks and future unintended consequences of biobank in both Germany and the UK. Specifically, notions of individual reciprocity were at the forefront in the context of personal disadvantages to participation, while communal reciprocity was prominent when potential and actual participants were discussing the uncertainty of the long-term nature of biobanking. The research indicates that reciprocity can be viewed as a mode to deal with individuals' concerns about participating in a biobank, both by acting as a return 'favor' or 'gift,' and through establishing an ongoing relationship between participants, researchers and society. It is suggested that future biobanking projects will need to flexibly combine individual and communal forms of reciprocity if they are to recruit and maintain sufficient numbers of participants. Copyright © 2012 S. Karger AG, Basel.
TU-F-201-00: Radiochromic Film Dosimetry Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
TU-F-201-01: General Aspects of Radiochromic Film Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niroomand-Rad, A.
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
Support needs and experiences of family members of wounded, injured or sick UK service personnel.
Verey, Anna; Keeling, M; Thandi, G; Stevelink, S; Fear, N
2017-12-01
When a service person has been wounded, injured or sick (WIS), family members may provide care during their recovery in an unpaid capacity. This may occur in diverse environments including hospitals, inpatient rehabilitation centres, in the community and at home. Thirty-seven family members of WIS personnel were interviewed regarding their support needs, family relationships and use of UK support services. Semistructured, in-depth telephone interviews were used, with data analysis undertaken using a thematic approach. 'Family member involvement' was the main theme under which four subthemes were situated: 'continuity of support', 'proactive signposting and initiating contact', 'psychoeducation and counselling' and 'higher risk groups'. Family members felt they might benefit from direct, consistent and continuous care regardless of the WIS person's injury or engagement type, and whether the WIS person was being treated in a hospital, rehabilitative centre or at home. The findings of this study suggest that family members of WIS personnel value proactive, direct and sustained communication from support service providers. We suggest that families of UK service personnel may benefit from family care coordinators, who could provide continuous and consistent care to family members of WIS personnel. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Are Asian cultures really less ageist than Western ones? It depends on the questions asked.
Vauclair, Christin-Melanie; Hanke, Katja; Huang, Li-Li; Abrams, Dominic
2017-04-01
Ageism is an increasing concern in ageing populations such as Asia and Europe. A prevalent assumption in psychology is that Eastern cultures may be less prone to ageism because of norms and values that honour and respect elders. Yet, evidence for this culture hypothesis is inconclusive. The current study examines this issue by comparing attitudes towards older people in an Eastern and Western samples of 184 young people from the UK and 249 from Taiwan. Attitudes to old age were measured both as meta-perceptions (the perceived normative context) and personal attitudes in regard to the cognitive, affective and behavioural components of ageism. Consistent with the culture hypothesis, meta-perceptions about competence and admiration were more positive in Taiwan than in the UK, yet other meta-perceptions were more negative pointing to the existence of old age subtypes. Personal attitudes about older people in regard to the affective and behavioural, but not the cognitive component, were more negative in Taiwan than in the UK. Thus, cultural differences in ageism are more nuanced than suggested by previous research. The importance of distinguishing between the normative context and personal attitudes as well as the different components of ageism is highlighted by the present findings. © 2016 The Authors. International Journal of Psychology published by John Wiley & Sons Ltd on behalf of International Union of Psychological Science.
ERIC Educational Resources Information Center
Hassan, Nedim
2017-01-01
Background: Person-centred planning, which commonly becomes formalised within services for people with learning disabilities through an Essential Lifestyle Plan (ELP), was intended to help place the choices of individuals at the forefront of service provision. However, beyond UK government policy rhetoric, scholars have raised issues regarding the…
Heffernan, John; Pilkington, Paul
2011-08-01
High levels of unemployment among persons with mental illness are a significant social disability. The individual placement and support (IPS) model of vocational support has been shown to be effective in establishing persons with mental health problems back into competitive employment in North America. Evidence outside North America is more limited. To examine the evidence for the effectiveness of the IPS model of supported employment within the United Kingdom. Systematic review of studies of the effectiveness of IPS conducted principally in the United Kingdom. The evidence base was small. Overall quality of evidence was fair. There is evidence that interventions with high fidelity to the IPS model increase the proportion of patients engaged in work or education/training over the short- to medium-term (6-18 months follow-up). More research is needed to improve the evidence base in relation to IPS within a UK context. Evaluation should focus on both the nature and quality of the employment gained, patient and service factors.
Gillard, Steve; Turner, Kati; Neffgen, Marion
2015-07-31
Concepts of recovery increasingly inform the development and delivery of mental health services internationally. In the UK recent policy advocates the application of recovery concepts to the treatment of personality disorders. However diagnosis and understanding of personality disorders remains contested, challenging any assumption that mainstream recovery thinking can be directly translated into personality disorders services. In a qualitative interview-based study understandings of recovery were explored in extended, in-depth interviews with six people purposively sampled from a specialist personality disorders' service in the UK. An interpretive, collaborative approach to research was adopted in which university-, clinical- and service user (consumer) researchers were jointly involved in carrying out interviews and analysing interview data. Findings suggested that recovery cannot be conceptualised separately from an understanding of the lived experience of personality disorders. This experience was characterised by a complexity of ambiguous, interrelating and conflicting feelings, thoughts and actions as individuals tried to cope with tensions between internally and externally experienced worlds. Our analysis was suggestive of a process of recovering or, for some, discovering a sense of self that can safely coexist in both worlds. We conclude that key facilitators of recovery - positive personal relationships and wider social interaction - are also where the core vulnerabilities of individuals with lived experience of personaility disorders can lie. There is a role for personality disorders services in providing a safe space in which to develop positive relationships. Through discursive practice within the research team understandings of recovery were co-produced that responded to the lived experience of personality disorders and were of applied relevance to practitioners.
Is dosimetry still a necessity in current dental practice?
Reddy, S S; Rakesh, N; Chauhan, Pallavi; Clint, Joseph Ben; Sharma, Shivani
2015-12-01
Today, dentists have a wide range of imaging modalities to choose from, the film based techniques, digital techniques, and the recent introduction of 3D volumetric or cone beam computed tomography (CBCT). The inherent design features of the new generation dental x-ray equipment has significantly improved over the years with no evidence of substandard x-ray units in operation. In dental facilities radiological workload is comparatively low, newer radiation equipments and accessories follow safety guidelines and employ better radiation protection measures for the patient and the operator. Dentists' knowledge and expertise in radiation protection measures is good, enabling them to carry out riskfree radiation procedures in their practice. Therefore, the present study is aimed at assessing the need for dosimeters in current dental scenario. 'Is there currently a significant risk from dental radiography to merit the use of personal dosimetery in dental practice. 'Dental health professionals (Oral radiologists) and radiographic assistants of fourteen dental colleges in Karnataka state participated in this questionnaire study. The questionnaire consisted of the following questions--the make, type, year of manufacture of radiographic machines used in their setup, number of radiographs made per day in the institution, type of receptors used, number of personnel at risk for radiation exposure, radiation protection measures used, regular monitoring by personal dosimeters, equivalent dosage readings for the past 12 months and whether the reading of thermoluminescent dosimeters (TLD) for any personnel had exceeded the recommended exposure value in the last 3 years. Dosimetry records of the radiology staff in the last three years shows doses no more than 1.50 mSv per year. The various institutions' dose (person mSv) was in the range of 3.70 mSv-3.90 mSv. Personal monitoring for Dentists can be omitted in the dental colleges since the estimated dose of oral radiologists contributed less than 0.01 mSv to the total average annual effective dose equivalent. Hence personal monitoring services (TLD Badges) for dentists employed in dental colleges should not be made mandatory.
Determination of transmission factors for beta radiation using Al 2O 3:C commercial OSL dosimeters
NASA Astrophysics Data System (ADS)
Pinto, T. N. O.; Caldas, L. V. E.
2010-07-01
In recent years, the optically stimulated luminescence (OSL) technique has been used in personal dosimetry, and aluminum oxide (Al 2O 3:C) has become a very useful material for this technique. The objective of this work was the determination of the transmission factors for beta radiation using Al 2O 3:C commercial dosimeters and the OSL method. The obtained results were similar to the transmission factors reported in the beta source calibration certificates.
Photoluminescence and Optically Stimulated Luminescence Studies of LiAlO2 and LiGaO2 Crystals
2015-03-26
tests from the past. In terms of personal dosimetry, OSL dosimeters could potentially replace ther- moluminescence dosimeters (TLDs) which are widely...used by individuals conducting research and maintaining nuclear weapons ( OSL dosimeters are a promising alterna- tive to TLDs because they do not...because they contain lithium, unlike Al2O3:C, the most commonly used OSL dosimeter [2]. The large neutron 1 cross section of lithium-6 makes enriched
The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology?
Wood, R E; Harris, A M; van der Merwe, E J; Nortjé, C J
1991-05-01
A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.
Incidence of shoulder dislocations in the UK, 1995-2015: a population-based cohort study.
Shah, Anjali; Judge, Andrew; Delmestri, Antonella; Edwards, Katherine; Arden, Nigel K; Prieto-Alhambra, Daniel; Holt, Tim A; Pinedo-Villanueva, Rafael A; Hopewell, Sally; Lamb, Sarah E; Rangan, Amar; Carr, Andrew J; Collins, Gary S; Rees, Jonathan L
2017-11-14
This cohort study evaluates the unknown age-specific and gender-specific incidence of primary shoulder dislocations in the UK. UK primary care data from the Clinical Practice Research Datalink (CPRD) were used to identify patients aged 16-70 years with a shoulder dislocation during 1995-2015. Coding of primary shoulder dislocations was validated using the CPRD general practitioner questionnaire service. A cohort of 16 763 patients with shoulder dislocation aged 16-70 years during 1995-2015 were identified. Incidence rates per 100 000 person-years and 95% CIs were calculated. Correct coding of shoulder dislocation within CPRD was 89% (95% CI 83% to 95%), and confirmation that the dislocation was a 'primary' was 76% (95% CI 67% to 85%). Seventy-two percent of shoulder dislocations occurred in men. The overall incidence rate in men was 40.4 per 100 000 person-years (95% CI 40.4 to 40.4), and in women was 15.5 per 100 000 person-years (95% CI 15.5 to 15.5). The highest incidence was observed in men aged 16-20 years (80.5 per 100 000 person-years; 95% CI 80.5 to 80.6). Incidence in women increased with age to a peak of 28.6 per 100 000 person-years among those aged 61-70 years. This is the first time the incidence of shoulder dislocations has been studied using primary care data from a national database, and the first time the results for the UK have been produced. While most primary dislocations occurred in young men, an unexpected finding was that the incidence increased in women aged over 50 years, but not in men. The reasons for this are unknown. Further work is commissioned by the National Institute for Health Research to examine treatments and predictors for recurrent shoulder dislocation. The design of this study was approved by the Independent Scientific Advisory Committee (15_260) for the Medicines & Healthcare products Regulatory Agency. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu-Tsao, S.
Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to)more » external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.« less
A method to characterise site, urban and regional ambient background radiation.
Passmore, C; Kirr, M
2011-03-01
Control dosemeters are routinely provided to customers to monitor the background radiation so that it can be subtracted from the gross response of the dosemeter to arrive at the occupational dose. Landauer, the largest dosimetry processor in the world with subsidiaries in Australia, Brazil, China, France, Japan, Mexico and the UK, has clients in approximately 130 countries. The Glenwood facility processes over 1.1 million controls per year. This network of clients around the world provides a unique ability to monitor the world's ambient background radiation. Control data can be mined to provide useful historical information regarding ambient background rates and provide a historical baseline for geographical areas. Historical baseline can be used to provide site or region-specific background subtraction values, document the variation in ambient background radiation around a client's site or provide a baseline for measuring the efficiency of clean-up efforts in urban areas after a dirty bomb detonation.
UK technical activities associated with the return to Earth of the MIR space station
NASA Astrophysics Data System (ADS)
Crowther, Richard; Tremayne-Smith, Richard
2002-11-01
The British National Space Centre (BNSC) acts as the focus in the United Kingdom (UK) for space-related activities. With the anticipated return to Earth of the MIR space station, BNSC established a group of technical experts to consider the associated implications for the UK, and to address both national and international activities relating to the planned de-orbit. In particular, the risk to the UK of an uncontrolled re-entry was considered in contingency planning and the means for the provision of accurate information to the public and media were established to ensure balanced view of the potential hazards that MIR posed to persons and property on the ground. The MIR de-orbit was exemplary, both in terms of the technical activities of the Rosaviakosmos and the safe disposal of MIR in the Pacific, and in relation to the open and effective communication between agencies and the positive reporting by the media.
Christensen, Nana L.; Jakobsen, Steen; Schacht, Anna C.; Munk, Ole L.; Alstrup, Aage K. O.; Tolbod, Lars P.; Harms, Hendrik J.; Nielsen, Søren
2017-01-01
Introduction: Despite the decades long use of [11C]palmitate positron emission tomography (PET)/computed tomography in basic metabolism studies, only personal communications regarding dosimetry and biodistribution data have been published. Methods: Dosimetry and biodistribution studies were performed in 2 pigs and 2 healthy volunteers by whole-body [11C]palmitate PET scans. Metabolite studies were performed in 40 participants (healthy and with type 2 diabetes) under basal and hyperinsulinemic conditions. Metabolites were estimated using 2 approaches and subsequently compared: Indirect [11C]CO2 release and parent [11C]palmitate measured by a solid-phase extraction (SPE) method. Finally, myocardial fatty acid uptake was calculated in a patient cohort using input functions derived from individual metabolite correction compared with population-based metabolite correction. Results: In humans, mean effective dose was 3.23 (0.02) µSv/MBq, with the liver and myocardium receiving the highest absorbed doses. Metabolite correction using only [11C]CO2 estimates underestimated the fraction of metabolites in studies lasting more than 20 minutes. Population-based metabolite correction showed excellent correlation with individual metabolite correction in the cardiac PET validation cohort. Conclusion: First, mean effective dose of [11C]palmitate is 3.23 (0.02) µSv/MBq in humans allowing multiple scans using ∼300 MBq [11C]palmitate, and secondly, population-based metabolite correction compares well with individual correction. PMID:29073808
MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry
NASA Astrophysics Data System (ADS)
Oliveira, Luiz C.; Yukihara, Eduardo G.; Baffa, Oswaldo
2016-04-01
The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emission spectrum of this new material and carried out a preliminary investigation on the OSL signal stability. MgO:Li,Ce,Sm has a main TL peak at ~180 °C (at a heating rate of 5 °C/s) associated with Ce3+ and Sm3+ emission. The results indicate that the infrared (870 nm) stimulated OSL from MgO:Li,Ce,Sm has suitable properties for dosimetry, including high sensitivity to ionizing radiation (20 times that of Al2O3:C, under the measurement conditions) and wide dynamic range (7 μGy-30 Gy). The OSL associated with Ce3+ emission is correlated with a dominant, practically isolated peak at 180 °C. Fading of ~15% was observed in the first hour, probably due to shallow traps, followed by subsequent fading of 6-7% over the next 35 days. These properties, together with the characteristically fast luminescence from Ce3+, make this material also a strong candidate for 2D OSL dose mapping.
MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry
Oliveira, Luiz C.; Yukihara, Eduardo G.; Baffa, Oswaldo
2016-01-01
The goal of this work was to investigate the relevant dosimetric and luminescent properties of MgO:Li3%,Ce0.03%,Sm0.03%, a newly-developed, high sensitivity Optically Stimulated Luminescence (OSL) material of low effective atomic number (Zeff = 10.8) and potential interest for medical and personal dosimetry. We characterized the thermoluminescence (TL), OSL, radioluminescence (RL), and OSL emission spectrum of this new material and carried out a preliminary investigation on the OSL signal stability. MgO:Li,Ce,Sm has a main TL peak at ~180 °C (at a heating rate of 5 °C/s) associated with Ce3+ and Sm3+ emission. The results indicate that the infrared (870 nm) stimulated OSL from MgO:Li,Ce,Sm has suitable properties for dosimetry, including high sensitivity to ionizing radiation (20 times that of Al2O3:C, under the measurement conditions) and wide dynamic range (7 μGy–30 Gy). The OSL associated with Ce3+ emission is correlated with a dominant, practically isolated peak at 180 °C. Fading of ~15% was observed in the first hour, probably due to shallow traps, followed by subsequent fading of 6–7% over the next 35 days. These properties, together with the characteristically fast luminescence from Ce3+, make this material also a strong candidate for 2D OSL dose mapping. PMID:27076349
DOE Office of Scientific and Technical Information (OSTI.GOV)
Straume, T.; Ricker, Y.; Thut, M.
1988-08-29
This database was constructed to support research in radiation biological dosimetry and risk assessment. Relevant publications were identified through detailed searches of national and international electronic databases and through our personal knowledge of the subject. Publications were numbered and key worded, and referenced in an electronic data-retrieval system that permits quick access through computerized searches on publication number, authors, key words, title, year, and journal name. Photocopies of all publications contained in the database are maintained in a file that is numerically arranged by citation number. This report of the database is provided as a useful reference and overview. Itmore » should be emphasized that the database will grow as new citations are added to it. With that in mind, we arranged this report in order of ascending citation number so that follow-up reports will simply extend this document. The database cite 1212 publications. Publications are from 119 different scientific journals, 27 of these journals are cited at least 5 times. It also contains reference to 42 books and published symposia, and 129 reports. Information relevant to radiation biological dosimetry and risk assessment is widely distributed among the scientific literature, although a few journals clearly dominate. The four journals publishing the largest number of relevant papers are Health Physics, Mutation Research, Radiation Research, and International Journal of Radiation Biology. Publications in Health Physics make up almost 10% of the current database.« less
Zakariaee, Seyed Salman; Mesbahi, Asghar; Keshtkar, Ahmad; Azimirad, Vahid
2014-01-01
Polymer gel dosimeter is the only accurate three dimensional (3D) dosimeter that can measure the absorbed dose distribution in a perfect 3D setting. Gel dosimetry by using optical computed tomography (OCT) has been promoted by several researches. In the current study, we designed and constructed a prototype OCT system for gel dosimetry. First, the electrical system for optical scanning of the gel container using a Helium-Neon laser and a photocell was designed and constructed. Then, the mechanical part for two rotational and translational motions was designed and step motors were assembled to it. The data coming from photocell was grabbed by the home-built interface and sent to a personal computer. Data processing was carried out using MATLAB software. To calibrate the system and tune up the functionality of it, different objects was designed and scanned. Furthermore, the spatial and contrast resolution of the system was determined. The system was able to scan the gel dosimeter container with a diameter up to 11 cm inside the water phantom. The standard deviation of the pixels within water flask image was considered as the criteria for image uniformity. The uniformity of the system was about ±0.05%. The spatial resolution of the system was approximately 1 mm and contrast resolution was about 0.2%. Our primary results showed that this system is able to obtain two-dimensional, cross-sectional images from polymer gel samples. PMID:24761377
Noble, Adam J; Robinson, Abbey; Snape, Darlene; Marson, Anthony G
2017-02-01
How to refer to someone with epilepsy is a divisive topic. Arguments for and against different approaches, including traditional adjective labels, disability-first labels, and person-first terms have been presented. The preferences of those with epilepsy and their family and friends have, though, never been determined. This study provides this information for the first time. Via epilepsy interest groups and organizations in the UK and Republic of Ireland, 638 patients and 333 significant others completed an online survey. Three distinct phrases were presented: "They're epileptic" (traditional label), "They're an epileptic person" (disability-first) and "That person has epilepsy" (person-first). Participants identified which they preferred and explained their choices. Patients' median age was 39, with 69% having experienced seizures in the prior 12months. Significant others were typically parents. Most (86.7%) patients and significant others (93.4%) favored the person-first term. Traditional and disability-first terms were "Disliked"/"Strongly disliked". Regression found it was not possible to reliably distinguish between participants favoring the different terms on the basis of demographics. Qualitative analysis of answers to open-ended questions, however, revealed most favored person-first terminology as by not including the word 'epileptic' and by affirming personhood before disability, it was felt to less likely restrict a listener's expectations or evoke the condition's negative association. It was also considered to suggest the person being referred to might have some mastery over their condition. The findings indicate consensus amongst these key stakeholders others for the use of person-first terminology in English. A truly informed debate on the topic can now begin. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Yeh, C. Rosa; Tao, Yu-Hui
2012-01-01
The use of personal response systems (PRS) in classrooms is gaining popularity in the higher education institutes of Taiwan. However, past research rarely adopts theories from the information system domains, and their focus was primarily on the UK and US context. Therefore, this study adopted a theory-based approach to explore the perceptions of…
ERIC Educational Resources Information Center
Hulme, Claire; Lisewski, Bernard
2010-01-01
In the UK, following guidelines set out by the Quality Assurance Agency, personal development planning (PDP) is now operational across all higher education (HE) awards. Like many policy initiatives, PDP requires change, and vital to its implementation are those who facilitate PDP at the grassroots level. Staff given the task of implementing PDP…
ERIC Educational Resources Information Center
Hurd, Stella
2006-01-01
This study investigated the experience of learners enrolled on an Open University (UK) French course, and included personality factors, motivation, and tutor and student roles. The data gathered via multiple elicitation methods gave useful insights into issues of special relevance to distance language education, in particular the lack of fit…
ERIC Educational Resources Information Center
Stephen, Dawn E.; O'Connell, Paul; Hall, Mike
2008-01-01
In highlighting a gulf between inclusive policy intentions inherent in the advent of mass higher education in the UK and the lived experiences of students and staff, this paper aims to stimulate critical debate about the impact of this changed environment upon traditional personal tutoring relationships. In drawing upon qualitative research with a…
Review on the characteristics of radiation detectors for dosimetry and imaging
NASA Astrophysics Data System (ADS)
Seco, Joao; Clasie, Ben; Partridge, Mike
2014-10-01
The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging systems, with silver halide films now largely obsolete for many applications. Nuclear medicine has benefited from more sensitive, faster and higher-resolution detectors delivering ever-higher SPECT and PET image quality. PET/MR systems have been enabled by the development of gamma ray detectors that can operate in high magnetic fields. These huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4DCT, PET and MRI routinely used in treatment planning and online image guidance provided by cone-beam CT. The challenge of ensuring safe, accurate and precise delivery of highly complex radiation fields has also both driven and benefited from advances in radiation detectors. Detector systems have been developed for the measurement of electron, intensity-modulated and modulated arc x-ray, proton and ion beams, and around brachytherapy sources based on a very wide range of technologies. The types of measurement performed are equally wide, encompassing commissioning and quality assurance, reference dosimetry, in vivo dosimetry and personal and environmental monitoring. In this article, we briefly introduce the general physical characteristics and properties that are commonly used to describe the behaviour and performance of both discrete and imaging detectors. The physical principles of operation of calorimeters; ionization and charge detectors; semiconductor, luminescent, scintillating and chemical detectors; and radiochromic and radiographic films are then reviewed and their principle applications discussed. Finally, a general discussion of the application of detectors for x-ray nuclear medicine and ion beam imaging and dosimetry is presented.
10 CFR 835.1304 - Nuclear accident dosimetry.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... nuclear accident is possible, shall provide nuclear accident dosimetry for those individuals. (b) Nuclear...
10 CFR 835.1304 - Nuclear accident dosimetry.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... nuclear accident is possible, shall provide nuclear accident dosimetry for those individuals. (b) Nuclear...
10 CFR 835.1304 - Nuclear accident dosimetry.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... nuclear accident is possible, shall provide nuclear accident dosimetry for those individuals. (b) Nuclear...
10 CFR 835.1304 - Nuclear accident dosimetry.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... nuclear accident is possible, shall provide nuclear accident dosimetry for those individuals. (b) Nuclear...
10 CFR 835.1304 - Nuclear accident dosimetry.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... nuclear accident is possible, shall provide nuclear accident dosimetry for those individuals. (b) Nuclear...
DOE Office of Scientific and Technical Information (OSTI.GOV)
McElroy, W.N.; Kellogg, L.S.; Matsumoto, W.Y.
1988-05-01
This report is in response to a request from Westinghouse Hanford Company (WHC) that the PNL National Dosimetry Center (NDC) perform physics-dosimetry analyses (E > MeV) for N Reactor Pressure Tubes 2954 and 3053. As a result of these analyses, and recommendations for additional studies, two physics-dosimetry re-evaluations for Pressure Tube 1165 were also accomplished. The primary objective of Pacific Northwest Laboratories' (PNL) National Dosimetry Center (NDC) physics-dosimetry work for N Reactor was to provide FERRET-SAND II physics-dosimetry results to assist in the assessment of neutron radiation-induced changes in the physical and mechanical properties of N Reactor pressure tubes. 15more » refs., 6 figs., 5 tabs.« less
Ulijaszek, Stanley J; McLennan, Amy K
2016-05-01
Since 1997, and despite several political changes, obesity policy in the UK has overwhelmingly framed obesity as a problem of individual responsibility. Reports, policies and interventions have emphasized that it is the responsibility of individual consumers to make personal changes to reduce obesity. The Foresight Report 'Tackling Obesities: Future Choices' (2007) attempted to reframe obesity as a complex problem that required multiple sites of intervention well beyond the range of personal responsibility. This framing formed the basis for policy and coincided with increasing acknowledgement of the complex nature of obesity in obesity research. Yet policy and interventions developed following Foresight, such as the Change4Life social marketing campaign, targeted individual consumer behaviour. With the Conservative-Liberal Democrat government of 2011, intervention shifted to corporate and individual responsibility, making corporations voluntarily responsible for motivating individual consumers to change. This article examines shifts in the framing of obesity from a problem of individual responsibility, towards collective responsibility, and back to the individual in UK government reports, policies and interventions between 1997 and 2015. We show that UK obesity policies reflect the landscape of policymakers, advisors, political pressures and values, as much as, if not more than, the landscape of evidence. The view that the individual should be the central site for obesity prevention and intervention has remained central to the political framing of population-level obesity, despite strong evidence contrary to this. Power dynamics in obesity governance processes have remained unchallenged by the UK government, and individualistic framing of obesity policy continues to offer the path of least resistance. © 2016 World Obesity.
True grit and genetics: predicting academic achievement from personality
Rimfeld, Kaili; Kovas, Yulia; Dale, Philip S.; Plomin, Robert
2015-01-01
Grit -- perseverance and passion for long-term goals -- has been shown to be a significant predictor of academic success, even after controlling for other personality factors. Here, for the first time, we use a UK-representative sample and a genetically sensitive design to unpack the etiology of grit and its prediction of academic achievement in comparison to well-established personality traits. For 4,642 16-year-olds (2,321 twin pairs), we used the Grit-S scale (Perseverance of Effort and Consistency of Interest), along with the Big-5 personality traits, to predict scores on the General Certificate of Secondary Education (GCSE) exams, which are administered UK-wide at the end of compulsory education. Twin analyses of Grit Perseverance yielded a heritability estimate of 37% (20% for Consistency of Interest) and no evidence for shared environmental influence. Personality, primarily Conscientiousness, predicts about 6% of the variance in GCSE scores, but Grit adds little to this prediction. Moreover, multivariate twin analyses showed that roughly two-thirds of the GCSE prediction is mediated genetically. Grit Perseverance of Effort and Big-5 Conscientiousness are to a large extent the same trait both phenotypically (r=0.53) and genetically (genetic correlation = 0. 86). We conclude that the etiology of Grit is highly similar to other personality traits, not only in showing substantial genetic influence but also in showing no influence of shared environmental factors. Personality significantly predicts academic achievement, but Grit adds little phenotypically or genetically to the prediction of academic achievement beyond traditional personality factors, especially Conscientiousness. PMID:26867111
2009-03-01
environment II.A: Characterization of dosimetry in IMRT radiobiological experiment phantom using TLDs and film. (7-10 mos.) Objectives: 1... dosimetry with TLDs and film. (8-10 mos.) 4. Analysis of measured dosimetry with TLDs and film compared to predicted dosimetry from treatment...cells were). Dosimetry in the phantom was assessed with film and monitor units were calculated accordingly to deliver the desired dose. Once in
Characterising an aluminium oxide dosimetry system.
Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor
2015-09-01
In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.
Griffin, Simon J; Borch-Johnsen, Knut; Davies, Melanie J; Khunti, Kamlesh; Rutten, Guy EHM; Sandbæk, Annelli; Sharp, Stephen J; Simmons, Rebecca K; van den Donk, Maureen; Wareham, Nicholas J; Lauritzen, Torsten
2011-01-01
Summary Background Intensive treatment of multiple cardiovascular risk factors can halve mortality among people with established type 2 diabetes. We investigated the effect of early multifactorial treatment after diagnosis by screening. Methods In a pragmatic, cluster-randomised, parallel-group trial done in Denmark, the Netherlands, and the UK, 343 general practices were randomly assigned screening of registered patients aged 40–69 years without known diabetes followed by routine care of diabetes or screening followed by intensive treatment of multiple risk factors. The primary endpoint was first cardiovascular event, including cardiovascular mortality and morbidity, revascularisation, and non-traumatic amputation within 5 years. Patients and staff assessing outcomes were unaware of the practice's study group assignment. Analysis was done by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00237549. Findings Primary endpoint data were available for 3055 (99·9%) of 3057 screen-detected patients. The mean age was 60·3 (SD 6·9) years and the mean duration of follow-up was 5·3 (SD 1·6) years. Improvements in cardiovascular risk factors (HbA1c and cholesterol concentrations and blood pressure) were slightly but significantly better in the intensive treatment group. The incidence of first cardiovascular event was 7·2% (13·5 per 1000 person-years) in the intensive treatment group and 8·5% (15·9 per 1000 person-years) in the routine care group (hazard ratio 0·83, 95% CI 0·65–1·05), and of all-cause mortality 6·2% (11·6 per 1000 person-years) and 6·7% (12·5 per 1000 person-years; 0·91, 0·69–1·21), respectively. Interpretation An intervention to promote early intensive management of patients with type 2 diabetes was associated with a small, non-significant reduction in the incidence of cardiovascular events and death. Funding National Health Service Denmark, Danish Council for Strategic Research, Danish Research Foundation for General Practice, Danish Centre for Evaluation and Health Technology Assessment, Danish National Board of Health, Danish Medical Research Council, Aarhus University Research Foundation, Wellcome Trust, UK Medical Research Council, UK NIHR Health Technology Assessment Programme, UK National Health Service R&D, UK National Institute for Health Research, Julius Center for Health Sciences and Primary Care, University Medical Center, Utrecht, Novo Nordisk, Astra, Pfizer, GlaxoSmithKline, Servier, HemoCue, Merck. PMID:21705063
A novel approach to neutron dosimetry.
Balmer, Matthew J I; Gamage, Kelum A A; Taylor, Graeme C
2016-11-01
Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (by around a factor of 2, although this is heavily dependent on the type of field). This conservatism could influence epidemiological studies on the health effects of radiation exposure. This paper reports on the development of an instrument which can estimate the effective dose of a neutron field, accounting for both the direction and the energy distribution. A 6 Li-loaded scintillator was used to perform neutron assays at a number of locations in a 20 × 20 × 17.5 cm 3 water phantom. The variation in thermal and fast neutron response to different energies and field directions was exploited. The modeled response of the instrument to various neutron fields was used to train an artificial neural network (ANN) to learn the effective dose and ambient dose equivalent of these fields. All experimental data published in this work were measured at the National Physical Laboratory (UK). Experimental results were obtained for a number of radionuclide source based neutron fields to test the performance of the system. The results of experimental neutron assays at 25 locations in a water phantom were fed into the trained ANN. A correlation between neutron counting rates in the phantom and neutron fluence rates was experimentally found to provide dose rate estimates. A radionuclide source behind shadow cone was used to create a more complex field in terms of energy and direction. For all fields, the resulting estimates of effective dose rate were within 45% or better of their calculated values, regardless of energy distribution or direction for measurement times greater than 25 min. This work presents a novel, real-time, approach to workplace neutron dosimetry. It is believed that in the research presented in this paper, for the first time, a single instrument has been able to estimate effective dose.
MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibbott, G.
Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by themore » development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.« less
An analysis of stress, burnout, and work commitment among disability support staff in the UK.
Smyth, Emmett; Healy, Olive; Lydon, Sinėad
2015-12-01
Previous research has suggested that challenging behaviour emitted by persons with intellectual and developmental disabilities negatively impacts upon the levels of stress and burnout of those who support and care for them. In the current study a sample of disability support workers in the UK (N=138) reported their levels of perceived stress, burnout, and commitment to their work. The relationship between the frequency and severity of aggressive/destructive behaviours to which they were exposed, and these three measures were examined. Results showed that participants scored lower on measures of burnout in the current study than has been reported by similar research studies in the UK and North America. The results revealed an association between challenging behaviours experienced and participants' perceived stress and emotional exhaustion. Perceived stress and burnout were also associated with participants' commitment to their work. Finally, a series of regression analyses identified a number of predictors of emotional exhaustion, depersonalization, and personal accomplishment among disability support workers. The results and their implications for the consideration of disability support worker wellbeing and future research in this area are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Protecting personal data in epidemiological research: DataSHIELD and UK law.
Wallace, Susan E; Gaye, Amadou; Shoush, Osama; Burton, Paul R
2014-01-01
Data from individual collections, such as biobanks and cohort studies, are now being shared in order to create combined datasets which can be queried to ask complex scientific questions. But this sharing must be done with due regard for data protection principles. DataSHIELD is a new technology that queries nonaggregated, individual-level data in situ but returns query data in an anonymous format. This raises questions of the ability of DataSHIELD to adequately protect participant confidentiality. An ethico-legal analysis was conducted that examined each step of the DataSHIELD process from the perspective of UK case law, regulations, and guidance. DataSHIELD reaches agreed UK standards of protection for the sharing of biomedical data. All direct processing of personal data is conducted within the protected environment of the contributing study; participating studies have scientific, ethics, and data access approvals in place prior to the analysis; studies are clear that their consents conform with this use of data, and participants are informed that anonymisation for further disclosure will take place. DataSHIELD can provide a flexible means of interrogating data while protecting the participants' confidentiality in accordance with applicable legislation and guidance. © 2014 S. Karger AG, Basel.
Macroscopic to Microscopic Scales of Particulate Dosimetry: From Source to Fate in the Body
Additional perspective with regards to particle dosimetry is achieved by exploring dosimetry across a range of scales from macroscopic to microscopic in scope. Typically, one thinks of dosimetry as what happens when a particle is inhaled, where it is deposited, and how it is clea...
ERIC Educational Resources Information Center
Alexander, R. T.; Green, F. N.; O'Mahony, B.; Gunaratna, I. J.; Gangadharan, S. K.; Hoare, S.
2010-01-01
Aim: To establish any differences between patients with and without a diagnosis of personality disorders, being treated in a secure inpatient service for offenders with intellectual disability (ID) in the UK. Method: A cohort study involving a selected population of people with ID and offending behaviours. Results: The study included a total of…
The Latin American Biological Dosimetry Network (LBDNet).
García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M
2016-09-01
Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Reference dosimeter system of the iaea
NASA Astrophysics Data System (ADS)
Mehta, Kishor; Girzikowsky, Reinhard
1995-09-01
Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.
Patient dosimetry audit for establishing local diagnostic reference levels for nuclear medicine CT.
Gardner, Matthew; Katsidzira, Ngonidzashe M; Ross, Erin; Larkin, Elizabeth A
2017-03-01
To establish a system for patient dosimetry audit and setting of local diagnostic reference levels (LDRLs) for nuclear medicine (NM) CT. Computed radiological information system (CRIS) data were matched with NM paper records, which provided the body region and dose mode for NMCT carried out at a large UK hospital. It was necessary to divide data in terms of the NM examination type, body region and dose mode. The mean and standard deviation dose-length products (DLPs) for common NMCT examinations were then calculated and compared with the proposed National Diagnostic Reference Levels (NDRLs). Only procedures which have 10 or more patients will be used to suggest LDRLs. For most examinations, the mean DLPs do not exceed the proposed NDRLs. The bone single-photon emission CT/CT lumbar spine data clearly show the need to divide data according to the purpose of the scan (dose mode), with mean (±standard error) DLPs ranging from 51 ± 5 mGy cm (low dose) to 1086 ± 124 mGy cm (metal dose). A system for NMCT patient dose audit has been developed, but there are non-trivial challenges which make the process labour intensive. These include limited information provided by CRIS downloads, dependence on paper records and limited number of examinations available owing to the need to subdivide data. Advances in knowledge: This article demonstrates that a system can be developed for NMCT patient dose audit, but also highlights the challenges associated with such audit, which may not be encountered with more routine audit of radiology CT.
Topical Review: Polymer gel dosimetry
Baldock, C; De Deene, Y; Doran, S; Ibbott, G; Jirasek, A; Lepage, M; McAuley, K B; Oldham, M; Schreiner, L J
2010-01-01
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. PMID:20150687
Predictors of fitness to practise declarations in UK medical undergraduates.
Paton, Lewis W; Tiffin, Paul A; Smith, Daniel; Dowell, Jon S; Mwandigha, Lazaro M
2018-04-05
Misconduct during medical school predicts subsequent fitness to practise (FtP) events in doctors, but relatively little is known about which factors are associated with such issues during undergraduate education. This study exploits the newly created UK medical education database (UKMED), with the aim of identifying predictors of conduct or health-related issues that could potentially impair FtP. The findings would have implications for policies related to both the selection and support of medical students. Data were available for 14,379 students obtaining provisional registration with the General Medical Council who started medical school in 2007 and 2008. FtP declarations made by students were available, as were various educational and demographic predictor variables, including self-report 'personality measures' for students who participated in UK Clinical Aptitude Test (UKCAT) pilot studies. Univariable and multivariable logistic regression models were developed to evaluate the predictors of FtP declarations. Significant univariable predictors (p < 0.05) for conduct-related declarations included male gender, white ethnicity and a non-professional parental background. Male gender (OR 3.07) and higher 'self-esteem' (OR 1.45) were independently associated with an increased risk of a conduct issue. Female gender, a non-professional background, and lower self-reported 'confidence' were, among others, associated with increased odds of a health-related declaration. Only 'confidence' was a significant independent predictor of a health declaration (OR 0.69). Female gender, higher UKCAT score, a non-professional background and lower 'confidence' scores were significant predictors of reported depression, and the latter two variables were independent predictors of declared depression. White ethnicity and UK nationality were associated with increased odds of both conduct and health-related declarations, as were certain personality traits. Students from non-professional backgrounds may be at increased risk of depression and therefore could benefit from targeted support. The small effect sizes observed for the 'personality measures' suggest they would offer little potential benefit for selection, over and above those measures already in use.
Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology
NASA Astrophysics Data System (ADS)
Borges, F. L. S.; Guimarães, M. C.; Da Silva, T. A.; Nogueira Tavares, M. S.
2014-11-01
Recently, the International Commission on Radiological Protection has reviewed epidemiological evidences suggesting that there were tissue reaction effects in the eye lens below the previously considered absorbed dose threshold. A new statement related to the eye lens was issued that changed the absorbed dose threshold and reduced the dose limits for occupationally exposed persons. As consequence, some planned exposures require eye lens dosimetry and a debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to study the methodology for calibrating the EYE-DTM holder with a TLD-100H Harshaw chip detector and to determine its angular and energy dependences in terms of personal dose equivalent, Hp(3).
Hughes, Julie; Herrington, Margaret; McDonald, Tess; Rhodes, Amy
2011-02-01
This paper analyses the use of an e-portfolio system in contributing to the personalized learning of two dyslexic learners at the University of Wolverhampton, UK. The rationale for this research rests at the intersection of generic findings from e-portfolio (and wider e-learning) research and the still challenging project in higher education (HE) of creating inclusive curricula. A qualitative, ethnographic approach was employed in a piece of collaborative research between academic staff and dyslexic learners. Two retrospective learner narratives were constructed and then reviewed by all co-authors in terms of the 'personalized fit' which they allowed with dyslexic thinking, learning and writing experience. The findings suggest a potential refinement of the general pedagogical claims about e-portfolio-based learning when considering dyslexic learners and thence the value of an enhanced prioritization of e-portfolio learning practices within inclusive HE curricula. The review and analysis also allow a 'critical' discussion of the practical and theoretical issues arising within this work. Copyright © 2010 John Wiley & Sons, Ltd.
Evaluation and implementation of triple‐channel radiochromic film dosimetry in brachytherapy
Bradley, David; Nisbet, Andrew
2014-01-01
The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple‐channel dosimetry has recently been utilized in external beam radiotherapy to improve the accuracy of film dosimetry, but its use in brachytherapy, with characteristic high maximum doses, steep dose gradients, and small scales, has been less well researched. We investigate the use of advanced film dosimetry techniques for brachytherapy dosimetry, evaluating uncertainties and assessing the mitigation afforded by triple‐channel dosimetry. We present results on postirradiation film darkening, lateral scanner effect, film surface perturbation, film active layer thickness, film curling, and examples of the measurement of clinical brachytherapy dose distributions. The lateral scanner effect in brachytherapy film dosimetry can be very significant, up to 23% dose increase at 14 Gy, at ± 9 cm lateral from the scanner axis for simple single‐channel dosimetry. Triple‐channel dosimetry mitigates the effect, but still limits the useable width of a typical scanner to less than 8 cm at high dose levels to give dose uncertainty to within 1%. Triple‐channel dosimetry separates dose and dose‐independent signal components, and effectively removes disturbances caused by film thickness variation and surface perturbations in the examples considered in this work. The use of reference dose films scanned simultaneously with brachytherapy test films is recommended to account for scanner variations from calibration conditions. Postirradiation darkening, which is a continual logarithmic function with time, must be taken into account between the reference and test films. Finally, films must be flat when scanned to avoid the Callier‐like effects and to provide reliable dosimetric results. We have demonstrated that radiochromic film dosimetry with GAFCHROMIC EBT3 film and a commercial flatbed scanner is a viable method for brachytherapy dose distribution measurement, and uncertainties may be reduced with triple‐channel dosimetry and specific film scan and evaluation methodologies. PACS numbers: 87.55.Qr, 87.56.bg, 87.55.km PMID:25207417
McManus, I C; Keeling, A; Paice, E
2004-08-18
The study investigated the extent to which approaches to work, workplace climate, stress, burnout and satisfaction with medicine as a career in doctors aged about thirty are predicted by measures of learning style and personality measured five to twelve years earlier when the doctors were applicants to medical school or were medical students. Prospective study of a large cohort of doctors. The participants were first studied when they applied to any of five UK medical schools in 1990. Postal questionnaires were sent to all doctors with a traceable address on the current or a previous Medical Register. The current questionnaire included measures of Approaches to Work, Workplace Climate, stress (General Health Questionnaire), burnout (Maslach Burnout Inventory), and satisfaction with medicine as a career and personality (Big Five). Previous questionnaires had included measures of learning style (Study Process Questionnaire) and personality. Doctors' approaches to work were predicted by study habits and learning styles, both at application to medical school and in the final year. How doctors perceive their workplace climate and workload is predicted both by approaches to work and by measures of stress, burnout and satisfaction with medicine. These characteristics are partially predicted by trait measures of personality taken five years earlier. Stress, burnout and satisfaction also correlate with trait measures of personality taken five years earlier. Differences in approach to work and perceived workplace climate seem mainly to reflect stable, long-term individual differences in doctors themselves, reflected in measures of personality and learning style.
McManus, IC; Keeling, A; Paice, E
2004-01-01
Background The study investigated the extent to which approaches to work, workplace climate, stress, burnout and satisfaction with medicine as a career in doctors aged about thirty are predicted by measures of learning style and personality measured five to twelve years earlier when the doctors were applicants to medical school or were medical students. Methods Prospective study of a large cohort of doctors. The participants were first studied when they applied to any of five UK medical schools in 1990. Postal questionnaires were sent to all doctors with a traceable address on the current or a previous Medical Register. The current questionnaire included measures of Approaches to Work, Workplace Climate, stress (General Health Questionnaire), burnout (Maslach Burnout Inventory), and satisfaction with medicine as a career and personality (Big Five). Previous questionnaires had included measures of learning style (Study Process Questionnaire) and personality. Results Doctors' approaches to work were predicted by study habits and learning styles, both at application to medical school and in the final year. How doctors perceive their workplace climate and workload is predicted both by approaches to work and by measures of stress, burnout and satisfaction with medicine. These characteristics are partially predicted by trait measures of personality taken five years earlier. Stress, burnout and satisfaction also correlate with trait measures of personality taken five years earlier. Conclusions Differences in approach to work and perceived workplace climate seem mainly to reflect stable, long-term individual differences in doctors themselves, reflected in measures of personality and learning style. PMID:15317650
MO-B-BRB-00: Three Dimensional Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by themore » development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.« less
MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juang, T.
Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by themore » development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.« less
MO-B-BRB-01: 3D Dosimetry in the Clinic: Background and Motivation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schreiner, L.
Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by themore » development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.« less
MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ceberg, S.
Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by themore » development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.« less
Advances in biological dosimetry
NASA Astrophysics Data System (ADS)
Ivashkevich, A.; Ohnesorg, T.; Sparbier, C. E.; Elsaleh, H.
2017-01-01
Rapid retrospective biodosimetry methods are essential for the fast triage of persons occupationally or accidentally exposed to ionizing radiation. Identification and detection of a radiation specific molecular ‘footprint’ should provide a sensitive and reliable measurement of radiation exposure. Here we discuss conventional (cytogenetic) methods of detection and assessment of radiation exposure in comparison to emerging approaches such as gene expression signatures and DNA damage markers. Furthermore, we provide an overview of technical and logistic details such as type of sample required, time for sample preparation and analysis, ease of use and potential for a high throughput analysis.
Quantitative imaging for clinical dosimetry
NASA Astrophysics Data System (ADS)
Bardiès, Manuel; Flux, Glenn; Lassmann, Michael; Monsieurs, Myriam; Savolainen, Sauli; Strand, Sven-Erik
2006-12-01
Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.
2009 Annual Health Physics Report for the HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2010-04-14
During the 2009 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2009, there were 159 person-trips that required dose monitoring of the U.S. monitors. Of the 159 person-trips, 149 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 4 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. LLNL's Hazard Control Departmentmore » laboratories provided the dosimetry services for the HEU Transparency monitors. In 2009, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency Program now has over fifteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less
Doing good when times are bad: volunteering behaviour in economic hard times.
Lim, Chaeyoon; Laurence, James
2015-06-01
This paper examines how the 2008-9 recession has affected volunteering behaviours in the UK. Using a large survey dataset, we assess the recession effects on both formal volunteering and informal helping behaviours. Whilst both formal volunteering and informal helping have been in decline in the UK since 2008, the size of the decline is significantly larger for informal helping than for formal volunteering. The decline is more salient in regions that experienced a higher level of unemployment during the recession and also in socially and economically disadvantaged communities. However, we find that a growing number of people who personally experienced financial insecurity and hardship do not explain the decline. We argue that the decline has more to do with community-level factors such as civic organizational infrastructure and cultural norms of trust and engagement than personal experiences of economic hardship. © London School of Economics and Political Science 2015.
Should Mitochondrial Donation Be Anonymous?
Appleby, John B
2018-01-01
Abstract Currently in the United Kingdom, anyone donating gametes has the status of an open-identity donor. This means that, at the age of 18, persons conceived with gametes donated since April 1, 2005 have a right to access certain pieces of identifying information about their donor. However, in early 2015, the UK Parliament approved new regulations that make mitochondrial donors anonymous. Both mitochondrial donation and gamete donation are similar in the basic sense that they involve the contribution of gamete materials to create future persons. Given this similarity, this paper presumes that both types of donor should be treated the same and made open-identity under the law, unless there is a convincing argument for treating them differently. I argue that none of the existing arguments that have been made so far in favor of mitochondrial donor anonymity are convincing and mitochondrial donors should therefore be treated as open-identity donors under UK law. PMID:29301011
Should Mitochondrial Donation Be Anonymous?
Appleby, John B
2018-03-13
Currently in the United Kingdom, anyone donating gametes has the status of an open-identity donor. This means that, at the age of 18, persons conceived with gametes donated since April 1, 2005 have a right to access certain pieces of identifying information about their donor. However, in early 2015, the UK Parliament approved new regulations that make mitochondrial donors anonymous. Both mitochondrial donation and gamete donation are similar in the basic sense that they involve the contribution of gamete materials to create future persons. Given this similarity, this paper presumes that both types of donor should be treated the same and made open-identity under the law, unless there is a convincing argument for treating them differently. I argue that none of the existing arguments that have been made so far in favor of mitochondrial donor anonymity are convincing and mitochondrial donors should therefore be treated as open-identity donors under UK law.
Winter, George
One in five people in the UK suffers an infectious intestinal disease (IID) each year. The most common sources are food, and person-to-person and animal-to-human spread. In 2004, a reported 15,898 people suffered IID. Of these, 134 were admitted to hospital and 11 died. The main agents in IID are viruses, bacteria, protozoa, worms and marine biotoxins. Gastroenteritis should always be considered infectious unless there is good evidence to suggest otherwise.
Relationship between student selection criteria and learner success for medical dosimetry students
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, Jamie, E-mail: jabaker@mdanderson.org; Tucker, Debra; Raynes, Edilberto
Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees)more » and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student's previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant's undergraduate cumulative GPA and increase the weight assigned to previous degrees.« less
Relationship between student selection criteria and learner success for medical dosimetry students.
Baker, Jamie; Tucker, Debra; Raynes, Edilberto; Aitken, Florence; Allen, Pamela
2016-01-01
Medical dosimetry education occupies a specialized branch of allied health higher education. Noted international shortages of health care workers, reduced university funding, limitations on faculty staffing, trends in learner attrition, and increased enrollment of nontraditional students force medical dosimetry educational leadership to reevaluate current admission practices. Program officials wish to select medical dosimetry students with the best chances of successful graduation. The purpose of the quantitative ex post facto correlation study was to investigate the relationship between applicant characteristics (cumulative undergraduate grade point average (GPA), science grade point average (SGPA), prior experience as a radiation therapist, and previous academic degrees) and the successful completion of a medical dosimetry program, as measured by graduation. A key finding from the quantitative study was the statistically significant positive correlation between a student׳s previous degree and his or her successful graduation from the medical dosimetry program. Future research investigations could include a larger research sample, representative of more medical dosimetry student populations, and additional studies concerning the relationship of previous work as a radiation therapist and the effect on success as a medical dosimetry student. Based on the quantitative correlation analysis, medical dosimetry leadership on admissions committees could revise student selection rubrics to place less emphasis on an applicant׳s undergraduate cumulative GPA and increase the weight assigned to previous degrees. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Properties of Principal TL (Thermoluminescence) Dosimeters.
1983-10-01
thermoluminescence dosimetry ( TLD ) emerged as the preferred means because of convenience of batch evaluation, reusability, large detection range, linearity and...personnel dosimetry , thermoluminescence dosimetry has emerged as a superior technique due to its manifold advantages over other methods of dose...their suitability for dosimetry . A brief description of important TL materials and their properties is documented in this report. DD ,JN 1473 EDITION 0
AFRRI Neutron Dosimetry and Radiobiology Conference
1988-11-09
Neutron Dosimetry and Radiobiology 8 - 9 November 1988 Sponsored by Defense Nuclear Agency ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE...neutron radiation is less amenable to amelioration by chemical radioprotectants and more difficult to assess by means of physical dosimetry . These...neutron dosimetry and radiobiology we have witnessed in the past several years,could not have been possible without the sustained efforts of many
Sixth international radiopharmaceutical dosimetry symposium: Proceedings. Volume 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.-Stelson, A.T.; Stabin, M.G.; Sparks, R.B.
1999-01-01
This conference was held May 7--10 in Gatlinburg, Tennessee. The purpose of this conference was to provide a multidisciplinary forum for exchange of state-of-the-art information on radiopharmaceutical dosimetry. Attention is focused on the following: quantitative analysis and treatment planning; cellular and small-scale dosimetry; dosimetric models; radiopharmaceutical kinetics and dosimetry; and animal models, extrapolation, and uncertainty.
Moran, Paul R.
1976-01-01
The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.
PREFACE: Third International Conference on Radiotherapy Gel Dosimetry
NASA Astrophysics Data System (ADS)
DeDeene, Yves; Baldock, Clive
2004-01-01
Gel dosimetry is not merely another dosimetry technique. Gel dosimeters are integrating dosimeters that enable dose verification in three dimensions. The application of a 3D dosimetry technique in the clinic would give a real push to the implementation of advanced high-precision radiotherapy technologies in many institutes. It can be expected that with the recent developments in the field towards more user-friendly gel systems and imaging modalities, gel dosimetry will become a vital link in the chain of high-precision radiation cancer therapy in the near future. Many researchers all over the world have contributed to the emerging technology of gel dosimetry. The research field of gel dosimetry is recognized to be very broad from polymer and analytical chemistry and material research to imaging technologies. The DOSGEL conferences in the past have proven to be an important forum at which material scientists, chemists, medical physicists, magnetic resonance imaging and radiation specialists brought together a critical mass of thoughts, findings and considerations. DOSGEL 2004 has been endorsed by many international, supra-national and national medical physics organizations and publishers. These proceedings contain 51 papers that cover various aspects of gel dosimetry.
NASA Astrophysics Data System (ADS)
Straube, Ulrich; Berger, Thomas
A significant expansion of Human presence in space can be recognized over the last decade. Not only the frequency of human space mission did rise, but also time in space, mission duration with extended flights lasting half a year or more are becoming "standard". Despite the challenges to human health and well-being are still significant, or may even increase with mission length and work density. Also radiation exposure in space remains one of the inevitable and dominating factors relevant to crew- health, -safety and therefore mission success. The radiation environment that the space crews are exposed to differs significantly as compared to earth. Exposure in flight exceed doses that are usually received by terrestrial radiation workers on ground. Expanding "medical" demands are not a solely characteristics of current and current and upcoming mission scenarios. Likewise the margins for what is understood as "efficient utilization" for the fully operational science platform ISS, are immense. Understanding, accepting and approaching these challenges ESA-HSO did choose a particular pass of implementation for one of their current developments. Exploiting synergies of research, science and medical operational aspects, the "European Crew Personal Active Dosimeter for Astronauts (EuCPAD)" development exactly addresses these circumstances. It becomes novel part of ESA Radiation Protection Initiative for astronauts. The EuCPAD project aims at the development and manufacturing of an active (powered) dosimeter system to measure astronaut's exposures, support risk assessment dose management by providing a differentiated data set. Final goal is the verification of the system capabilities for medical monitoring at highest standards. The EuCPAD consists of several small portable Personal Active Dosimeters (MU = Mobile Unitas) and a rack mounted docking station “Personal Storage Device (PSD)” for MU storage, data read out and telemetry. The PSD furthermore contains a Tissue Equivalent Proportional Counter (TEPC) and an internal MU(iMU) to enable complex environmental measurements and cross calibrations. This presentation will give an introduction to the dosimetry system and of the current status. The EuCPAD project is carried out under ESA Contract No. 4200023059/09/NL/CP,
Technical considerations for implementation of x-ray CT polymer gel dosimetry.
Hilts, M; Jirasek, A; Duzenli, C
2005-04-21
Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy practice. X-ray CT has been shown to be a feasible method of reading out polymer gel dosimeters and, with the high accessibility of CT scanners to cancer hospitals, presents an exciting possibility for clinical implementation of gel dosimetry. In this study we report on technical considerations for implementation of x-ray CT polymer gel dosimetry. Specifically phantom design, CT imaging methods, imaging time requirements and gel dose response are investigated. Where possible, recommendations are made for optimizing parameters to enhance system performance. The dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. Results are compared with MRI and optical CT polymer gel dosimetry results available in the literature.
Accessing personal medical records online: a means to what ends?
Shah, Syed Ghulam Sarwar; Fitton, Richard; Hannan, Amir; Fisher, Brian; Young, Terry; Barnett, Julie
2015-02-01
Initiatives in the UK to enable patients to access their electronic health records (EHRs) are gathering momentum. All citizens of the European Union should have access to their records by 2015, a target that the UK has endorsed. To identify the ways in which patients used their access to their EHRs, what they sought to achieve, and the extent to which EHR access was related to the concept of making savings. An audit of patients' online access to medical records was conducted in July-August 2011 using a survey questionnaire. Two hundred and twenty six patients who were registered with two general practices in the National Health Service (NHS) located in the UK and who had accessed their personal EHRs at least twice in the preceding 12 months i.e. from July 2010 to July 2011, completed the questionnaire. Data analysis A thematic analysis of the comments that patients gave in response to the open ended questions on the questionnaire. Overall, evaluations of record access were positive. Four main themes relating to the ways in which patients accessed their records were identified: making savings, checking past activity, preparation for future action, and setting new expectations. Quite apart from any benefits of savings in healthcare resources, this study has provided qualitative evidence of the active ways in which patients may make use of access to their EHRs, many of which are in line with proportionate health management strategies. Access to personal EHRs may contribute to the development of new expectations among patients. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Sun safety knowledge and practice in UK postal delivery workers.
Houdmont, J; Davis, S; Griffiths, A
2016-06-01
Postal delivery workers spend a large proportion of their work time outdoors, placing them at increased risk of skin cancer. To date, no studies have examined occupational sun safety knowledge and practice within this group in the UK. To describe the occupational sun safety knowledge and practice of UK postal delivery workers and to investigate the association of demographic, personal and occupational factors with knowledge and practice in order to identify potential strategies for improving sun safety in this occupational group. Postal delivery workers completed a questionnaire that collected data on occupational sun safety knowledge and practice in addition to demographic, personal and workplace characteristics. One-way analysis of variances were applied to assess differences in knowledge and practice by these characteristics. A total of 1153 postal delivery workers completed the questionnaire, a 60% response rate. Thirty-three per cent reported receiving sun safety training within the previous 12 months. The majority of respondents reported correct knowledge on three of the six domains and good practice on four of the six behavioural domains. However, only one-fifth of respondents reported wearing sunglasses and ensuring a plentiful intake of water. Knowledge and practice differed significantly according to demographic, personal and workplace characteristics. There is a need to raise the profile of occupational skin cancer in this occupational group and to increase the priority given to occupational sun safety policies alongside targeted and tailored interventions, the effect of which can be evaluated. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine.
Computer Aided Dosimetry and Verification of Exposure to Radiation
2002-06-01
Event matrix 2. Hematopoietic * Absolute blood counts * Relative blood counts 3. Dosimetry * TLD * EPDQuantitative * Radiation survey * Whole body...EI1 Defence Research and Recherche et developpement Development Canada pour la d6fense Canada DEFENCE •mI•DEFENSE Computer Aided Dosimetry and...Aided Dosimetry and Verification of Exposure to Radiation Edward Waller SAIC Canada Robert Z Stodilka Radiation Effects Group, Space Systems and
Design and Calibration of a X-Ray Millibeam
2005-12-01
developed for use in Fricke dosimetry , parallel-plate ionization chambers, Lithium Fluoride thermoluminescent dosimetry ( TLD ), and EBT GafChromic...thermoluminescent dosimetry ( TLD ), and EBT GafChromic film to characterize the spatial distribution and accuracy of the doses produced by the Faxitron. A...absorbed dose calibration factors for use in Fricke dosimetry , parallel-plate ionization chambers, Lithium Fluoride (LiF) TLD , and EBT GafChromic film. The
Risk Assessment in the UK Health and Safety System: Theory and Practice.
Russ, Karen
2010-09-01
In the UK, a person or organisation that creates risk is required to manage and control that risk so that it is reduced 'So Far As Is Reasonably Practicable' (SFAIRP). How the risk is managed is to be determined by those who create the risk. They have a duty to demonstrate that they have taken action to ensure all risk is reduced SFAIRP and must have documentary evidence, for example a risk assessment or safety case, to prove that they manage the risks their activities create. The UK Health and Safety Executive (HSE) does not tell organisations how to manage the risks they create but does inspect the quality of risk identification and management. This paper gives a brief overview of where responsibility for occupational health and safety lies in the UK, and how risk should be managed through risk assessment. The focus of the paper is three recent major UK incidents, all involving fatalities, and all of which were wholly avoidable if risks had been properly assessed and managed. The paper concludes with an analysis of the common failings of risk assessments and key actions for improvement.
The (mis)management of migrant nurses in the UK: a sociological study.
Adhikari, Radha; Melia, Kath M
2015-04-01
To examine Nepali migrant nurses' professional life in the UK. In the late 1990 s the UK experienced an acute nursing shortage. Within a decade over 1000 Nepali nurses migrated to the UK. A multi-sited ethnographic approach was chosen for this study. Between 2006 and 2009, 21 in-depth interviews with Nepali nurses were conducted in the UK using snowballing sampling. Nepali migrant nurses are highly qualified and experienced in specialised areas such as critical care, management and education. However, these nurses end up working in the long-term care sector, providing personal care for elderly people - an area commonly described by migrant nurses as British Bottom Care (BBC). This means that migrant nurses lack career choices and professional development opportunities, causing them frustration and lack of job satisfaction. International nurse migration is an inevitable part of globalisation in health. Nurse managers and policy makers need to explore ways to make better use of the talents of the migrant workforce. We offer a management strategy to bring policies for the migrant workforce into line with the wider workforce plans by supporting nurses in finding jobs relevant to their expertise and providing career pathways. © 2013 John Wiley & Sons Ltd.
Nowak, Marta Justyna; Buchanan, Heather; Asimakopoulou, Koula
2018-07-01
Effective communication between patients and health professionals is a key component of patient-centred care. Although there is a large body of literature focusing on doctor-patient communication, there has been limited research related to dentist-patient communication, especially presented from the dentists' perspective. The aim of our study was to explore UK dentists' perceptions of communication in their consultations, and the factors they perceive may influence this. We conducted semi-structured interviews with eight dentists in UK dental NHS practices. Thematic analysis revealed three themes ('Treating the whole person', 'Barriers to patient-centred communication' and 'Mutuality of communication'), which reflected the dentists' perceptions of their own communication during consultations, the patients' interaction skills, attitudes (and characteristics that may affect them), and external factors, such as time constraints, that can influence dentist-patients' encounters. These in-depth accounts are valuable, in that we see what dentists perceive is important, obstructive and facilitative. They report using a patient-centred approach in their everyday dental practice; however this is often difficult due to factors such as time constraints. Although they emphasized that the patient has an active role to play in the communication process, it may be the case that they also need to play their part in facilitating this.
MO-A-BRB-01: TG191: Clinical Use of Luminescent Dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kry, S.
This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less
MO-A-BRB-00: TG191: Clinical Use of Luminescent Dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less
Assessment of national dosimetry quality audits results for teletherapy machines from 1989 to 2015.
Muhammad, Wazir; Ullah, Asad; Mahmood, Khalid; Matiullah
2016-01-01
The purpose of this study was to ensure accuracy in radiation dose delivery, external dosimetry quality audit has an equal importance with routine dosimetry performed at clinics. To do so, dosimetry quality audit was organized by the Secondary Standard Dosimetry Laboratory (SSDL) of Pakistan Institute of Nuclear Science and Technology (PINSTECH) at the national level to investigate and minimize uncertainties involved in the measurement of absorbed dose, and to improve the accuracy of dose measurement at different radiotherapy hospitals. A total of 181 dosimetry quality audits (i.e., 102 of Co-60 and 79 of linear accelerators) for teletherapy units installed at 22 different sites were performed from 1989 to 2015. The percent deviation between users’ calculated/stated dose and evaluated dose (in the result of on-site dosimetry visits) were calculated and the results were analyzed with respect to the limits of ± 2.5% (ICRU "optimal model") ± 3.0% (IAEA on-site dosimetry visits limit) and ± 5.0% (ICRU minimal or "lowest acceptable" model). The results showed that out of 181 total on-site dosimetry visits, 20.44%, 16.02%, and 4.42% were out of acceptable limits of ± 2.5% ± 3.0%, and ± 5.0%, respectively. The importance of a proper ongoing quality assurance program, recommendations of the followed protocols, and properly calibrated thermometers, pressure gauges, and humidity meters at radiotherapy hospitals are essential in maintaining consistency and uniformity of absorbed dose measurements for precision in dose delivery.
2003-06-18
Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs ) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...34Digital Mammography Breast Dosimetry Using Copper- Doped Lithium Fluoride (LiF:MCP) Thermoluminescent Dosimeters ( TLDs )" Author: LT John J. Tomon...Title of Thesis: " Digital Mammography Breast Dosimetry Using Copper-Doped Lithium Fluoride (LiF:MCP) Thermoluminescent
Development of a Multileaf Collimator for Proton Radiotherapy
2010-06-01
generated and compared to the dosimetry derived from radiochromic media. TLDS may be inserted into the phantom to further confirm the technique. Finally...of dosimetry systems for scanned beams: (FY 2006-2009). We are investigating dosimetry systems for use with scanned beams and will either purchase a...group Research in Monte Carlo Simulations and Dosimetry Studies of Proton Therapy Rulon Mayer, PhD Energetic protons used to damage tumors
Osooli, M; Steen Carlsson, K; Astermark, J; Berntorp, E
2017-09-01
Persons with severe haemophilia require lifelong replacement therapy, prophylaxis, to prevent bleeding. Data describing long-term outcomes of prophylactic treatment are scarce. The aim of this study was to investigate joint surgery and survival among persons with severe haemophilia with special attention to access to prophylaxis in the early years of life. Eligible participants had severe haemophilia A or B and were treated at the Malmö centre from the 1960s onward. Time from birth until joint surgery was analysed for participants negative for factor inhibitor and alive in 2000. We compared survival among the entire cohort with severe haemophilia treated at the Malmö centre with the general male population of Sweden and a sample of persons with severe haemophilia from the United Kingdom (UK). Overall, 167 participants were included, 106 (63.5%) of whom had complete data on joint surgery. Among those born before 1970, 1970-1979 and ≥1980 approximately 37%, 21% and 0% had their first joint surgery by age 30, respectively. There were no second joint surgeries reported in cohorts born ≥1970. Persons with severe haemophilia and negative for HIV treated in Malmö have attained approximately similar survival to that of the general male population in Sweden and live slightly longer than persons with severe haemophilia from the UK. Prophylaxis in Sweden, although costly, has markedly improved survival and joint outcomes for persons with severe haemophilia. This study highlights the importance of early start of replacement therapy to prevent or postpone serious joint damage. © 2017 John Wiley & Sons Ltd.
On the Eicosanoid Trail with John Vane and Jack McGiff: 1974-1976. A personal reminiscence.
Flower, R J
2015-07-01
In this brief personal reminiscence I comment upon the friendship and mutual understanding that arose between two great scientists and co-travellers, John Vane and Jack McGiff. I relate the events that led up to their meeting and focus on the brief period of time when they worked together on eicosanoid pharmacology in the UK. Copyright © 2015 Elsevier Inc. All rights reserved.
Hoggart, Lesley
2018-05-21
This paper scrutinises the concepts of moral reasoning and personal reasoning, problematising the binary model by looking at young women's pregnancy decision-making. Data from two UK empirical studies are subjected to theoretically driven qualitative secondary analysis, and illustrative cases show how complex decision-making is characterised by an intertwining of the personal and the moral, and is thus best understood by drawing on moral relativism.
Samuels, Alec; Barrister, J P
2007-10-01
In the UK, patients have a statutory right to refuse treatment. Parliament has authorised 'advance decision' whereby a person can specify his or her wishes regarding further medical treatment. Although the advance decision may give a person peace of mind, it could create real problems for doctors and other healthcare professionals. This article will examine the conditions and procedures surrounding the drawing up of an advance decision as well as some of the problems that could arise such as layman's language.
Personal exposures and microenvironment concentrations of PM 2.5, VOC, NO 2 and CO in Oxford, UK
NASA Astrophysics Data System (ADS)
Lai, H. K.; Kendall, M.; Ferrier, H.; Lindup, I.; Alm, S.; Hänninen, O.; Jantunen, M.; Mathys, P.; Colvile, R.; Ashmore, M. R.; Cullinan, P.; Nieuwenhuijsen, M. J.
Between 1998 and 2000 in Oxford, UK, simultaneous personal exposures and microenvironmental measurements (home indoor, home outdoor and work indoor) to fine particulate matters PM 2.5, volatile organic compounds (VOC), nitrogen dioxide (NO 2) and carbon monoxide (CO) were carried out once per person among 50 adults over a 48-h period. Thirty-seven elements in PM 2.5 and 30 different VOCs were analysed. Questionnaires were distributed to record their time-activity patterns and exposure-related information. Results showed that participants spent more time (89.5%) in all indoors than in other microenvironments. Geometric mean (GM) of personal and home indoor levels of PM 2.5, 14 elements (aluminium, arsenic, bromine, calcium, copper, iron, gallium, potassium, sodium, phosphorus, lead, selenium, silicon, titanium), total VOC (TVOC) and 8 individual compounds (nonane, decane, undecane, trimethylbenzene, toluene, benzaldehyde, alpha-pinene and d-limonene) were over 20% higher than their GM outdoor levels. Those of NO 2, 5 aromatic VOCs (benzene, o-xylene, ethylbenzene, propylbenzene, m, p-xylene) and 5 other elements (chlorine, magnesium, manganese, sulphur, zinc) were close to their GM outdoor levels. For PM 2.5 and TVOC, personal exposures and residential indoor levels (in GM) were about 2 times higher among the tobacco-smoke exposed group compared to the non-smoke exposed group, suggesting that smoking is an important determinant of these exposures. Determinants for CO were visualised by real-time monitoring, and we showed that the peak levels of personal exposure to CO were associated with smoking, cooking and transportation activities. Moderate to good correlations were only found between the personal exposures and residential indoor levels for both PM 2.5 ( r=0.60, p<0.001) and NO 2 ( r=0.47, p=0.003).
The history and future of accelerator radiological protection.
Thomas, R H
2001-01-01
The development of accelerator radiological protection from the mid-1930s, just after the invention of the cyclotron, to the present day is described. Three major themes--physics, personalities and politics--are developed. In the sections describing physics the development of shielding design though measurement, radiation transport calculations, the impact of accelerators on the environment and dosimetry in accelerator radiation fields are described. The discussion is limited to high-energy, high-intensity electron and proton accelerators. The impact of notable personalities on the development of both the basic science and on the accelerator health physics profession itself is described. The important role played by scholars and teachers is discussed. In the final section. which discusses the future of accelerator radiological protection, some emphasis is given to the social and political aspects that must he faced in the years ahead.
Gompels, Mark; Delpech, Valerie; Porter, Kholoud; Post, Frank; Johnson, Margaret; Dunn, David; Palfreeman, Adrian; Gilson, Richard; Gazzard, Brian; Hill, Teresa; Walsh, John; Fisher, Martin; Orkin, Chloe; Ainsworth, Jonathan; Bansi, Loveleen; Phillips, Andrew; Leen, Clifford; Nelson, Mark; Anderson, Jane; Sabin, Caroline
2011-01-01
Objectives To estimate life expectancy for people with HIV undergoing treatment compared with life expectancy in the general population and to assess the impact on life expectancy of late treatment, defined as CD4 count <200 cells/mm3 at start of antiretroviral therapy. Design Cohort study. Setting Outpatient HIV clinics throughout the United Kingdom. Population Adult patients from the UK Collaborative HIV Cohort (UK CHIC) Study with CD4 count ≤350 cells/mm3 at start of antiretroviral therapy in 1996-2008. Main outcome measures Life expectancy at the exact age of 20 (the average additional years that will be lived by a person after age 20), according to the cross sectional age specific mortality rates during the study period. Results 1248 of 17 661 eligible patients died during 91 203 person years’ follow-up. Life expectancy (standard error) at exact age 20 increased from 30.0 (1.2) to 45.8 (1.7) years from 1996-9 to 2006-8. Life expectancy was 39.5 (0.45) for male patients and 50.2 (0.45) years for female patients compared with 57.8 and 61.6 years for men and women in the general population (1996-2006). Starting antiretroviral therapy later than guidelines suggest resulted in up to 15 years’ loss of life: at age 20, life expectancy was 37.9 (1.3), 41.0 (2.2), and 53.4 (1.2) years in those starting antiretroviral therapy with CD4 count <100, 100-199, and 200-350 cells/mm3, respectively. Conclusions Life expectancy in people treated for HIV infection has increased by over 15 years during 1996-2008, but is still about 13 years less than that of the UK population. The higher life expectancy in women is magnified in those with HIV. Earlier diagnosis and subsequent timely treatment with antiretroviral therapy might increase life expectancy. PMID:21990260
'Home from home': risk perceptions, malaria and the use of chemoprophylaxis among UK South Asians.
Joshi, Mary Sissons; Lalvani, Ajit
2010-08-01
Malaria is a serious disease hazard facing travellers to tropical countries. On average around 2000 cases of malaria are annually imported into the UK, with an over-representation of ethnic minority members. The current research examined adherence to chemoprophylaxis among UK South Asians travelling to malarial regions in South Asia and East Africa. Four hundred South Asians were interviewed with a questionnaire investigating use of malaria prophylaxis, knowledge of malaria, risk perceptions and reasons for inadequate or zero adherence to chemoprophylaxis. Two hundred interviews were conducted in 1994, and a further 200 interviews in 2004. Participants were recruited from areas of known ethnic density in Leicester, London and Oxford. In 1994, although 49% embarked on taking anti-malaria tablets, only 22% took tablets for 2 or more weeks upon return to the UK (and only 6% for the medically advisory period of 4 weeks). In 2004, 32% embarked on taking tablets but only 9% took tablets for 2 or more weeks upon returning to the UK (and only 2.5% for 4 weeks). Good adherence was associated with greater knowledge about the symptoms and transmission of malaria, and being more likely to define the trip as a 'holiday' rather than as a visit to 'family and friends'. Zero adherence was associated with a failure to recognise the potential severity and critical nature of malaria. Common reasons for partial and zero adherence were the perception that the personal risk of getting malaria was low and an erroneous belief in immunity. The specific cognitions available to ethnic minority members travelling 'home' contribute to a very low use of chemoprophylaxis, thus placing them at a heightened risk of acquiring malaria. Health messages need to stress that malaria is a serious health hazard and that emigres visiting malarial regions cannot rely on personal immunity.
NASA Astrophysics Data System (ADS)
Giostra, A.; Richetta, E.; Pasquino, M.; Miranti, A.; Cutaia, C.; Brusasco, G.; Pellerito, R. E.; Stasi, M.
2016-06-01
Treatment with radioiodine is a standard procedure for patients with well-differentiated thyroid cancer, but the main approach to the therapy is still empiric, consisting of the administration of fixed activities. A predictive individualized dosimetric study may represent an important tool for physicians to determine the best activity to prescribe. The aim of this work is to compare red marrow and blood absorbed dose values obtained in the pre-treatment (PT) dosimetry phase with those obtained in the in-treatment (IT) dosimetry phase in order to estimate the predictive power of PT trial doses and to determine if they can be used as a decision-making tool to safely administer higher 131I activity to potentially increase the efficacy of treatment. The PT and IT dosimetry for 50 patients has been evaluated using three different dosimetric approaches. In all three approaches blood and red marrow doses, are calculated as the sum of two components, the dose from 131I activity in the blood and the dose from 131I activity located in the remainder of the body (i.e. the blood and whole-body contributions to the total dose). PT and IT dose values to blood and red marrow appear to be well correlated irrespective of the dosimetric approach used. Linear regression analyses of PT and IT total doses, for blood and red marrow, and the whole-body contribution to these doses, showed consistent best fit slope and correlation coefficient values of approximately 0.9 and 0.6, respectively: analyses of the blood dose contribution to the total doses also yielded similar values for the best fit slope but with correlation coefficient values of approximately 0.4 reflecting the greater variance in these dose estimates. These findings suggest that pre-treatment red marrow dose assessments may represent an important tool to personalize metastatic thyroid cancer treatment, removing the constraints of a fixed activity approach and permitting potentially more effective higher 131I activities to be safely used in-treatment.
NASA Astrophysics Data System (ADS)
Salas-Ramirez, Maikol; Tran-Gia, Johannes; Kesenheimer, Christian; Weng, Andreas Max; Kosmala, Aleksander; Heidemeier, Anke; Köstler, Herbert; Lassmann, Michael
2018-01-01
Absorbed dose to active bone marrow is a predictor of hematological toxicity in molecular radiotherapy. Due to the complex composition of bone marrow tissue, the necessity to improve the personalized dosimetry has led to the application of non-conventional imaging methods in nuclear medicine. The aim of this study is to apply magnetic resonance imaging (MRI) for quantification of the fat fraction in lumbar vertebrae and to analyze its implications for bone marrow dosimetry. First, a highly accelerated two-point Dixon MRI sequence for fat-water separation was validated in a 3T system against the magnetic resonance spectroscopy (MRS) gold standard. The validation was performed in a fat-water phantom composed of 11 vials with different fat fractions between 0% and 100%, and subsequently repeated in the lumbar vertebrae of three healthy volunteers. Finally, a retrospective study was performed by analyzing the fat fraction in five lumbar vertebrae of 44 patients scanned with the two-point Dixon sequence. The two-point Dixon phantom acquisition showed a good agreement (maximum difference = 2.9%) between the nominal fat fraction and MRS. In the volunteers, a statistical analysis showed a non-significant difference (p = 0.19) between MRI and MRS. In the patients, gender-specific linear fits for female and male data indicated that the age-dependent marrow conversion (red → yellow marrow) is slower in males (0.3% per year) than in females (0.5% per year). Lastly, the fat fraction values showed a considerable variability in patients of similar ages and the same gender. Two-point Dixon MRI enables a non-invasive and spatially resolved quantification of the fat fraction in bone marrow. Our study provides important evidence on the differences in marrow conversion between females and males. In addition, differences were observed in the cellularity values of the International Commission on Radiological Protection (ICRP) reference man (0.7) and the median values obtained in our patient group. These observations lead to the conclusion that the fat fraction in bone marrow should be considered as a patient-specific variable in clinical dosimetry procedures.
Salas-Ramirez, Maikol; Tran-Gia, Johannes; Kesenheimer, Christian; Weng, Andreas Max; Kosmala, Aleksander; Heidemeier, Anke; Köstler, Herbert; Lassmann, Michael
2018-01-16
Absorbed dose to active bone marrow is a predictor of hematological toxicity in molecular radiotherapy. Due to the complex composition of bone marrow tissue, the necessity to improve the personalized dosimetry has led to the application of non-conventional imaging methods in nuclear medicine. The aim of this study is to apply magnetic resonance imaging (MRI) for quantification of the fat fraction in lumbar vertebrae and to analyze its implications for bone marrow dosimetry. First, a highly accelerated two-point Dixon MRI sequence for fat-water separation was validated in a 3T system against the magnetic resonance spectroscopy (MRS) gold standard. The validation was performed in a fat-water phantom composed of 11 vials with different fat fractions between 0% and 100%, and subsequently repeated in the lumbar vertebrae of three healthy volunteers. Finally, a retrospective study was performed by analyzing the fat fraction in five lumbar vertebrae of 44 patients scanned with the two-point Dixon sequence. The two-point Dixon phantom acquisition showed a good agreement (maximum difference = 2.9%) between the nominal fat fraction and MRS. In the volunteers, a statistical analysis showed a non-significant difference (p = 0.19) between MRI and MRS. In the patients, gender-specific linear fits for female and male data indicated that the age-dependent marrow conversion (red → yellow marrow) is slower in males (0.3% per year) than in females (0.5% per year). Lastly, the fat fraction values showed a considerable variability in patients of similar ages and the same gender. Two-point Dixon MRI enables a non-invasive and spatially resolved quantification of the fat fraction in bone marrow. Our study provides important evidence on the differences in marrow conversion between females and males. In addition, differences were observed in the cellularity values of the International Commission on Radiological Protection (ICRP) reference man (0.7) and the median values obtained in our patient group. These observations lead to the conclusion that the fat fraction in bone marrow should be considered as a patient-specific variable in clinical dosimetry procedures.
Recent Progress in Electromagnetic Absorption and Dosimetry in Biological Systems.
1978-12-21
AEROSPACE M!DICAL RESEARCH LABORATORY NAVAL AIR STATION PENSACOLA, FLORIDA 32508 L4 oj6L I SUMMARY PAGE Ti9(PROSLEM Dosimetry , as a subset of research In...absonce of sound dosimetry design, lacks credibility. This study provides a usable orientation in present and future dosimetric technology through a...leading experiment; while at other times experimental results lead the way. Progress In absorption and dosimetry Is still urderway, and higher degrees
Nonuniform Irradiation of the Canine Intestine. 2. Dosimetry
1990-01-01
irradiation is accurate assessment In vivo dosimetry was done using Harshaw (Solon, Ohio) TLD - 100 lith- of the injury after either accidental or... vivo TLD dosimetry system allowed measure- 5 and 6. The dose was determined from the median TLD ment of the °Co dose deposited in the canine small...provide replicate measurements. Two separate dosimetry tubes were deveoped (Fig. 1). The first contained 30 TLD cap- doses (1). Nevertheless, current
Thermoluminescence Dosimetry (TLD) and its Application in Medical Physics
NASA Astrophysics Data System (ADS)
Azorín Nieto, Juan
2004-09-01
Radiation dosimetry is fundamental in Medical Physics, involving patients and phantom dosimetry. In both cases thermoluminescence dosimetry (TLD) is the most appropriate technique for measuring the absorbed dose. In this paper thermoluminescence phenomenon as well as the use of TLD in radiodiagnosis and radiotherapy for in vivo or in phantom measurements is discussed. Some results of measurements made in radiotherapy and radiodiagnosis using home made LiF:Mg,Cu,P+PTFE TLD are presented.
[Verification of the dose delivered to the patient by means of TLD, SC, PID. What future?].
Noël, A
2003-11-01
Among the different possibilities to check the accuracy of the treatment delivered, only in vivo dosimetry ensures the precision of the dose delivered to the patient during the treatment. In 1970-1980, Ruden assessed the use of thermoluminescent dosimetry to perform in vivo measurements at Radiumemmet in Stockholm. Straightforward in its principle but demanding in its implementation, thermoluminescent dosimetry has largely been used. Today, thanks to the work of Rikner, the use of semiconductor detectors allows the general implementation of in vivo dosimetry. Tomorrow, we will use electronic portal imaging device to verify the geometrical patient setup and the dose delivery at the same time. Its implementation remains complex and will need the development of algorithms to compute exit dose or midplane dose using portal in vivo dosimetry. First clinical results show that portal imaging is an accurate alternative for conventional in vivo dosimetry using diodes.
EURADOS strategic research agenda: vision for dosimetry of ionising radiation
Rühm, W.; Fantuzzi, E.; Harrison, R.; Schuhmacher, H.; Vanhavere, F.; Alves, J.; Bottollier Depois, J. F.; Fattibene, P.; Knežević, Ž.; Lopez, M. A.; Mayer, S.; Miljanić, S.; Neumaier, S.; Olko, P.; Stadtmann, H.; Tanner, R.; Woda, C.
2016-01-01
Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises—based on input from EURADOS Working Groups (WGs) and Voting Members—five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org). PMID:25752758
Technical basis for external dosimetry at the Waste Isolation Pilot Plant (WIPP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, E.W.; Wu, C.F.; Goff, T.E.
1993-12-31
The WIPP External Dosimetry Program, administered by Westinghouse Electric Corporation, Waste Isolation Division, for the US Department of Energy (DOE), provides external dosimetry support services for operations at the Waste Isolation Pilot Plant (WIPP) Site. These operations include the receipt, experimentation with, storage, and disposal of transuranic (TRU) wastes. This document describes the technical basis for the WIPP External Radiation Dosimetry Program. The purposes of this document are to: (1) provide assurance that the WIPP External Radiation Dosimetry Program is in compliance with all regulatory requirements, (2) provide assurance that the WIPP External Radiation Dosimetry Program is derived from amore » sound technical base, (3) serve as a technical reference for radiation protection personnel, and (4) aid in identifying and planning for future needs. The external radiation exposure fields are those that are documented in the WIPP Final Safety Analysis Report.« less
Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system.
Hanson, Ian M; Hansen, Vibeke N; Olaciregui-Ruiz, Igor; van Herk, Marcel
2014-10-07
Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients.The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min.The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7 ± 3.2)%.EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.
Clinical implementation and rapid commissioning of an EPID based in-vivo dosimetry system
NASA Astrophysics Data System (ADS)
Hanson, Ian M.; Hansen, Vibeke N.; Olaciregui-Ruiz, Igor; van Herk, Marcel
2014-10-01
Using an Electronic Portal Imaging Device (EPID) to perform in-vivo dosimetry is one of the most effective and efficient methods of verifying the safe delivery of complex radiotherapy treatments. Previous work has detailed the development of an EPID based in-vivo dosimetry system that was subsequently used to replace pre-treatment dose verification of IMRT and VMAT plans. Here we show that this system can be readily implemented on a commercial megavoltage imaging platform without modification to EPID hardware and without impacting standard imaging procedures. The accuracy and practicality of the EPID in-vivo dosimetry system was confirmed through a comparison with traditional TLD in-vivo measurements performed on five prostate patients. The commissioning time required for the EPID in-vivo dosimetry system was initially prohibitive at approximately 10 h per linac. Here we present a method of calculating linac specific EPID dosimetry correction factors that allow a single energy specific commissioning model to be applied to EPID data from multiple linacs. Using this method reduced the required per linac commissioning time to approximately 30 min. The validity of this commissioning method has been tested by analysing in-vivo dosimetry results of 1220 patients acquired on seven linacs over a period of 5 years. The average deviation between EPID based isocentre dose and expected isocentre dose for these patients was (-0.7 ± 3.2)%. EPID based in-vivo dosimetry is now the primary in-vivo dosimetry tool used at our centre and has replaced nearly all pre-treatment dose verification of IMRT treatments.
Norris, Emma; Myers, Lynn
2013-11-01
Despite evident protective value of motorcycle personal protective equipment (PPE), no research has assessed considerations behind its uptake in UK riders. A cross-sectional online questionnaire design was employed, with riders (n=268) recruited from online motorcycle forums. Principal component analysis found four PPE behavioural outcomes. Theoretical factors of intentions, attitudes, injunctive and descriptive subjective norms, risk perceptions, anticipated regret, benefits and habit were also identified for further analysis. High motorcycle jacket, trousers and boots wear, middling high-visibility wear and low non-Personal Protective Equipment wear were found. Greater intentions, anticipated regret and perceived benefits were significantly associated with increased motorcycle jacket, trousers and boots wear, with habit presence and scooter use significantly associated with increased high-visibility wear. Lower intentions, anticipated regret and risk perceptions, being female, not holding a car licence and urban riding were significantly associated with increased non-PPE wear. A need for freedom of choice and mixed attitudes towards PPE use were evident in additional comments. PPE determinants in this sample provide a preliminary basis for future uptake interventions. Larger scale and qualitative research is needed to further investigate relevant constructs. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ipe, N E; Rosser, K E; Moretti, C J; Manning, J W; Palmer, M J
2001-08-01
This paper evaluates the characteristics of ionization chambers for the measurement of absorbed dose to water using very low-energy x-rays. The values of the chamber correction factor, k(ch), used in the IPEMB 1996 code of practice for the UK secondary standard ionization chambers (PTW type M23342 and PTW type M23344), the Roos (PTW type 34001) and NACP electron chambers are derived. The responses in air of the small and large soft x-ray chambers (PTW type M23342 and PTW type M23344) and the NACP and Roos electron ionization chambers were compared. Besides the soft x-ray chambers, the NACP and Roos chambers can be used for very low-energy x-ray dosimetry provided that they are used in the restricted energy range for which their response does not change by more than 5%. The chamber correction factor was found by comparing the absorbed dose to water determined using the dosimetry protocol recommended for low-energy x-rays with that for very low-energy x-rays. The overlap energy range was extended using data from Grosswendt and Knight. Chamber correction factors given in this paper are chamber dependent, varying from 1.037 to 1.066 for a PTW type M23344 chamber, which is very different from a value of unity given in the IPEMB code. However, the values of k(ch) determined in this paper agree with those given in the DIN standard within experimental uncertainty. The authors recommend that the very low-energy section of the IPEMB code is amended to include the most up-to-date values of k(ch).
Broughton, J; Cantone, M C; Ginjaume, M; Shah, B; Czarwinski, R
2015-06-01
In April 2011, the International Commission on Radiological Protection issued a statement on reduction of the equivalent dose limits for the lens of the eye, and strongly recommended its consideration in the revision of the International Atomic Energy Agency's International Basic Safety Standards on Radiation Protection. The reduced dose limit was incorporated in the final version of the Basic Safety Standards. As significant concern was expressed by radiation protection professionals worldwide, the International Radiation Protection Association (IRPA) established a task group to assess the impact of implementation of the revised dose limit for the lens of the eye for occupational exposure. IRPA Associate Societies (ASs) were asked for their views using a questionnaire addressing three topics: implications for dosimetry, implications for methods of protection, and wider implications. The responses received indicate various methods of approach and express different points of view, reflecting nuances of particular ASs or specific professional groups. Topic experts nominated by ASs were selected to assist with collation of responses, and a report was produced by the task group. Conclusions were drawn on the three issues, including potential cost implications. A number of recommendations were drawn from the responses received including: the request for more understanding about the relationship between exposure of the lens of the eye and cataract formation, and further guidance to assist implementation; the importance of economic and social considerations when introducing the limits into national regulations; the need to propose or define procedures related to employment of people with existing or pre-cataract conditions; and the practical aspects relating to dosimetry and protective equipment. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Arulrajah, Poojani; Steele, Sarah
2018-06-13
Human trafficking is a serious violation of human rights, with numerous consequences for health and wellbeing. Recent law and policy reforms mean that clinicians now hold a crucial role in national strategies. 2015 research, however, indicates a serious shortfall in knowledge and confidence among healthcare professionals in the UK, leading potentially to failures in safeguarding and appropriate referral. Medical education is a central point for trafficking training. We ascertain the extent of such training in UK Medical Schools, and current curricular design. We sent Freedom of Information requests to the 34 public UK medical schools, which included a preliminary question on education provision, supplemented with follow-up questions exploring the nature, delivery and format of any education, as well as future curriculum development. There was a response rate of 97%. A majority (72%) of the schools did not provide trafficking education. 13% of these did, however, offer opportunities outside the formal curriculum. 70% had no plans to implement any education opportunities. Among the 28% of schools providing teaching, 56% integrated this within the core curriculum. 56% only delivered this within a single year of the degree. 67% provided some form of teaching in-person, while 78% used a combination of methods. Medical education on trafficking in the UK is variable and often absent. To produce future clinicians who are competent and capable, there is a need for expanded education on trafficking and research into optimal curriculum design. The UK's new Independent Anti-Slavery Commissioner should work with medical schools to develop an educational strategy urgently to fulfil the UK Government's plans and commitments. Both in the UK and around the world, human trafficking education presents a critical opportunity to address human rights and safeguarding to a generation of new doctors.
Comparing UK, USA and Australian values for EQ-5D as a health utility measure of oral health.
Brennan, D S; Teusner, D N
2015-09-01
Using generic measures to examine outcomes of oral disorders can add additional information relating to health utility. However, different algorithms are available to generate health states. The aim was to assess UK-, US- and Australian-based algorithms for the EuroQol (EQ-5D) in relation to their discriminative and convergent validity. Methods: Data were collected from adults in Australia aged 30-61 years by mailed survey in 2009-10, including the EQ-5D and a range of self-reported oral health variables, and self-rated oral and general health. Responses were collected from n=1,093 persons (response rate 39.1%). UK-based EQ-5D estimates were lower (0.85) than the USA and Australian estimates (0.91). EQ-5D was associated (p<0.01) with all seven oral health variables, with differences in utility scores ranging from 0.03 to 0.06 for the UK, from 0.04 to 0.07 for the USA, and from 0.05 to 0.08 for the Australian-based estimates. The effect sizes (ESs) of the associations with all seven oral health variables were similar for the UK (ES=0.26 to 0.49), USA (ES=0.31 to 0.48) and Australian-based (ES=0.31 to 0.46) estimates. EQ-5D was correlated with global dental health for the UK (rho=0.29), USA (rho=0.30) and Australian-based estimates (rho=0.30), and correlations with global general health were the same (rho=0.42) for the UK, USA and Australian-based estimates. EQ-5D exhibited equivalent discriminative validity and convergent validity in relation to oral health variables for the UK, USA and Australian-based estimates.
NASA Astrophysics Data System (ADS)
Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.
2017-06-01
Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.
[The use of polymer gel dosimetry to measure dose distribution around metallic implants].
Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa
2014-10-01
A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances.
Teaching leadership: the medical student society model.
Matthews, Jacob H; Morley, Gabriella L; Crossley, Eleanor; Bhanderi, Shivam
2018-04-01
All health care professionals in the UK are expected to have the medical leadership and management (MLM) skills necessary for improving patient care, as stipulated by the UK General Medical Council (GMC). Newly graduated doctors reported insufficient knowledge about leadership and quality improvement skills, despite all UK medical schools reporting that MLM is taught within their curriculum. A medical student society organised a series of extracurricular educational events focusing on leadership topics. The society recognised that the events needed to be useful and interesting to attract audiences. Therefore, clinical leaders in exciting fields were invited to talk about their experiences and case studies of personal leadership challenges. The emphasis on personal stories, from respected leaders, was a deliberate strategy to attract students and enhance learning. Evaluation data were collected from the audiences to improve the quality of the events and to support a business case for an intercalated degree in MLM. When leadership and management concepts are taught through personal stories, students find it interesting and are prepared to give up their leisure time to engage with the subject. Students appear to recognise the importance of MLM knowledge to their future careers, and are able to organise their own, and their peers', learning and development. Organising these events and collecting feedback can provide students with opportunities to practise leadership, management and quality improvement skills. These extracurricular events, delivered through a student society, allow for subjects to be discussed in more depth and can complement an already crowded undergraduate curriculum. Newly graduated doctors reported insufficient knowledge about leadership and quality improvement skills. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
Shafe, Anna C. E.; Lee, Sally; Dalrymple, Jamie S. O.; Whorwell, Peter J.
2011-01-01
Background: Despite the high prevalence of constipation and its related public health implications, there is relatively little research available on the condition from large epidemiological studies. The aim of this study was to investigate the epidemiology of general practitioner (GP)-diagnosed constipation and the prescribing trends for laxatives in the UK, within the general population and during pregnancy. Methods: A cohort study for the period from 2005 to 2009 was performed using the UK primary care database (General Practice Research Database), which contains information on over 3 million individuals. Results: The prevalence of GP-diagnosed constipation ranged from 12 per 1000 persons in 2005 (0.012 per person year) to 12.8 per 1000 in 2009 (0.013 per person year). The prevalence was almost twice as high in women as in men, and was higher in older patients. In 2005 the most commonly prescribed laxatives were lactulose (37%), senna (26%), macrogol (19%), ispaghula (6%), docusate sodium (5%), bisacodyl (4%) and glycerol suppositories (2%). By 2009, this pattern had changed: macrogol (31%), lactulose (29%), senna (22%), ispaghula (5%), docusate sodium (6%), bisacodyl (3%) and glycerol suppositories (3%). In pregnancy, lactulose accounted for 81% of laxative use in 2005, falling to 64% by 2009. In contrast, macrogol use in pregnancy rose from 13% in 2005 to 32% in 2009. Conclusions: GP-diagnosed constipation is common, accounting for a large number of consultations. Laxative prescribing trends have changed over the 5-year study period, prescriptions for macrogol becoming increasingly common and prescriptions for lactulose and senna less common. Macrogol also appears to have been replacing lactulose for treating constipation in pregnant women. PMID:22043228
Why students leave in the UK: an integrative review of the international research literature.
Cameron, Joan; Roxburgh, Michelle; Taylor, Julie; Lauder, William
2011-04-01
The purpose of this integrative review of the literature was to find and review international research studies that explored student attrition to determine what is known about the topic and to identify gaps in the research with a view to addressing the situation in the UK. Attrition from nursing programmes is a serious problem in the UK. It is recognised as a complex phenomenon, not attributable to a single cause. Regardless of actual attrition rates and trends, departments of nursing are challenged to perform in a business-like manner. Consequently, every student lost to a programme of study equates to a financial penalty for the department and to the future workforce and community. Integrative review of the literature. Using electronic databases and specific search terms, 18 articles were identified and reviewed. Findings from the identified international research literature were analysed using qualitative content analysis. Four broad themes that accounted for factors of relevance to attrition were identified: Social, Prediction, Programme and Personal. Retention studies are fraught with methodological problems. These include incomplete or inaccurate data and low response rates. Attrition early in programmes may be attributed to a failure to understand the roles of nurses in contemporary societies. This has led to dissatisfaction with programmes and academic failure, as students may underestimate the intellectual demands of their programmes. Attrition later in the programme may be attributed to a combination of personal factors that culminate in a personal crisis. The research literature suggests that stereotyping of nurses is a major factor in attrition. Both professions need to find ways of communicating contemporary roles to wider society. © 2010 Blackwell Publishing Ltd.
Draper, Heather; Jenkins, Simon
2017-12-19
As part of its response to the 2014 Ebola outbreak in west Africa, the United Kingdom (UK) government established an Ebola treatment unit in Sierra Leone, staffed by military personnel. Little is known about the ethical challenges experienced by military medical staff on humanitarian deployment. We designed a qualitative study to explore this further with those who worked in the treatment unit. Semi-structured, face-to-face and telephone interviews were conducted with 20 UK military personnel deployed between October 2014 and April 2015 in one of three roles in the Ebola treatment unit: clinician; nursing and nursing assistant; and other medical support work, including infection control and laboratory and mortuary services. Many participants reported feeling ethically motivated to volunteer for deployment, but for some personal interests were also a consideration. A small minority had negative feelings towards the deployment, others felt that this deployment like any other was part of military service. Almost all had initial concerns about personal safety but were reassured by their pre-deployment 'drills and skills', and personal protective equipment. Risk perceptions were related to perceptions about military service. Efforts to minimise infection risk were perceived to have made good patient care more difficult. Significantly, some thought the humanitarian nature of the mission justified tolerating greater risks to staff. Trust in the military institution and colleagues was expressed; many participants referred to the ethical obligation within the chain of command to protect those under their command. Participants expected resources to be overwhelmed and 'empty beds' presented a significant and pervasive ethical challenge. Most thought more patients could and should have been treated. Points of reference for participants' ethical values were: previous deployment experience; previous UK/National Health Service experience; professional ethics; and, distinctly military values (that might not be shared with non-military workers). We report the first systematic exploration of the ethical challenges face by a Western medical military in the international response to the first major Ebola outbreak. We offer unique insights into the military healthcare workers' experiences of humanitarian deployment. Many participants expressed motivations that gave them common purpose with civilian volunteers.
2008-05-21
Albedo Dosimetry TLDs that are used for neutron or neutron-photon personnel dosimetry are albedo dosimeters. The word albedo simply means the proportion... dosimetry . When LiF: MCP is exposed to thermal neutron irradiation, there is no obvious change in the glow curve shape. In the case of TLD -100, the...LiF: MCP undergoes compared to TLD -100. Therefore, LET results in significant variations in TL output for LiF: MCP. Limitations of Albedo Dosimetry
1987-04-01
and would still be well under 10(C. .% % p., I V a- E p - -12 - IABLE 8 (a) TLD results for phantom dosimetry - all values shown are measured charge...SAI. Conclusions The current DREO dosimetry system-consisting of bubble, CR39 and TLD dosimeters - has proven capable of producing meaningful results at...MC FILE CoPy’ Defence nationale 00 ANTHROPOMORPHIC PHANTOM RADIATION DOSIMETRY AT THE NATO STANDARD OREFERENCE POINT AT ABERDEEN PROVING GROUND by T
Type testing of the Siemens Plessey electronic personal dosemeter.
Hirning, C R; Yuen, P S
1995-07-01
This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.
Quantitative evaluation of patient-specific quality assurance using online dosimetry system
NASA Astrophysics Data System (ADS)
Jung, Jae-Yong; Shin, Young-Ju; Sohn, Seung-Chang; Min, Jung-Whan; Kim, Yon-Lae; Kim, Dong-Su; Choe, Bo-Young; Suh, Tae-Suk
2018-01-01
In this study, we investigated the clinical performance of an online dosimetry system (Mobius FX system, MFX) by 1) dosimetric plan verification using gamma passing rates and dose volume metrics and 2) error-detection capability evaluation by deliberately introduced machine error. Eighteen volumetric modulated arc therapy (VMAT) plans were studied. To evaluate the clinical performance of the MFX, we used gamma analysis and dose volume histogram (DVH) analysis. In addition, to evaluate the error-detection capability, we used gamma analysis and DVH analysis utilizing three types of deliberately introduced errors (Type 1: gantry angle-independent multi-leaf collimator (MLC) error, Type 2: gantry angle-dependent MLC error, and Type 3: gantry angle error). A dosimetric verification comparison of physical dosimetry system (Delt4PT) and online dosimetry system (MFX), gamma passing rates of the two dosimetry systems showed very good agreement with treatment planning system (TPS) calculation. For the average dose difference between the TPS calculation and the MFX measurement, most of the dose metrics showed good agreement within a tolerance of 3%. For the error-detection comparison of Delta4PT and MFX, the gamma passing rates of the two dosimetry systems did not meet the 90% acceptance criterion with the magnitude of error exceeding 2 mm and 1.5 ◦, respectively, for error plans of Types 1, 2, and 3. For delivery with all error types, the average dose difference of PTV due to error magnitude showed good agreement between calculated TPS and measured MFX within 1%. Overall, the results of the online dosimetry system showed very good agreement with those of the physical dosimetry system. Our results suggest that a log file-based online dosimetry system is a very suitable verification tool for accurate and efficient clinical routines for patient-specific quality assurance (QA).
MacKenzie, R K; Dowell, J; Ayansina, D; Cleland, J A
2017-05-01
Traditional methods of assessing personality traits in medical school selection have been heavily criticised. To address this at the point of selection, "non-cognitive" tests were included in the UK Clinical Aptitude Test, the most widely-used aptitude test in UK medical education (UKCAT: http://www.ukcat.ac.uk/ ). We examined the predictive validity of these non-cognitive traits with performance during and on exit from medical school. We sampled all students graduating in 2013 from the 30 UKCAT consortium medical schools. Analysis included: candidate demographics, UKCAT non-cognitive scores, medical school performance data-the Educational Performance Measure (EPM) and national exit situational judgement test (SJT) outcomes. We examined the relationships between these variables and SJT and EPM scores. Multilevel modelling was used to assess the relationships adjusting for confounders. The 3343 students who had taken the UKCAT non-cognitive tests and had both EPM and SJT data were entered into the analysis. There were four types of non-cognitive test: (1) libertariancommunitarian, (2) NACE-narcissism, aloofness, confidence and empathy, (3) MEARS-self-esteem, optimism, control, self-discipline, emotional-nondefensiveness (END) and faking, (4) an abridged version of 1 and 2 combined. Multilevel regression showed that, after correcting for demographic factors, END predicted SJT and EPM decile. Aloofness and empathy in NACE were predictive of SJT score. This is the first large-scale study examining the relationship between performance on non-cognitive selection tests and medical school exit assessments. The predictive validity of these tests was limited, and the relationships revealed do not fit neatly with theoretical expectations. This study does not support their use in selection.
A cross-sectional study of the presence of United Kingdom (UK) plastic surgeons on social media.
Mabvuure, Nigel Tapiwa; Rodrigues, Jeremy; Klimach, Stefan; Nduka, Charles
2014-03-01
To determine the uptake and usage of websites and social media (SM) by UK consultant (attending) plastic surgeons. Professional profiles of full BAPRAS members were searched on Facebook, Twitter, LinkedIn, RealSelf, YouTube, ResearchGate in May 2013. Additional surgeons were identified from the follower lists of @BAPRASvoice and @BAAPSMedia. Website ownership was determined on Google. Searches were repeated three times. Dual BAAPS-BAPRAS members were identified from www.baaps.org.uk. There were 156 (48.3%) dual BAAPS-BAPRAS members and 36 BAPRAS-only members. Fifty seven (18%) surgeons had no account on any platform whereas 266 (82%) were on at least one platform. One hundred and sixty four (51%) had personal websites whilst 37 (11%) had profiles on partnership websites. One hundred and sixteen (36%) had no website presence whilst 2% had websites under construction. The platform most surgeons use is LinkedIn (52%) whilst smaller proportions used Facebook (4%) and Twitter (22%). Surgeons had a mean of 126 (range: 0-3270) Twitter followers and 368 (range: 7-3786) fans/'likes' of their Facebook profiles. Time spent in postgraduate practice was not predictive of website ownership or SM use. However, dual BAAPS-BAPRAS members were significantly more likely to own a personal website, Twitter, RealSelf and YouTube accounts. There has been an increase in the uptake of social media by UK plastic surgeons, especially in those with aesthetic surgery interests. However, very few surgeons have optimised their web presence. Continued education and appropriate usage guidance may promote uptake, particularly by reconstructive surgeons. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The physics of small megavoltage photon beam dosimetry.
Andreo, Pedro
2018-02-01
The increased interest during recent years in the use of small megavoltage photon beams in advanced radiotherapy techniques has led to the development of dosimetry recommendations by different national and international organizations. Their requirement of data suitable for the different clinical options available, regarding treatment units and dosimetry equipment, has generated a considerable amount of research by the scientific community during the last decade. The multiple publications in the field have led not only to the availability of new invaluable data, but have also contributed substantially to an improved understanding of the physics of their dosimetry. This work provides an overview of the most important aspects that govern the physics of small megavoltage photon beam dosimetry. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Baldock, C.
2017-05-01
John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and including 2016. Themes and trends of the gel dosimetry research field were bibliometrically explored by way of co-occurrence term maps using the titles and abstracts text corpora from the Web of Science database for all relevant papers from 1984 to 2016. Visualisation of similarities was used by way of the VOSviewer visualisation tool to generate cluster maps of gel dosimetry knowledge domains and the associated citation impact of topics within the domains. Heat maps were then generated to assist in the understanding of active growth areas, research trends, and emerging and hot topics in gel dosimetry.
EURADOS strategic research agenda: vision for dosimetry of ionising radiation.
Rühm, W; Fantuzzi, E; Harrison, R; Schuhmacher, H; Vanhavere, F; Alves, J; Bottollier Depois, J F; Fattibene, P; Knežević, Ž; Lopez, M A; Mayer, S; Miljanić, S; Neumaier, S; Olko, P; Stadtmann, H; Tanner, R; Woda, C
2016-02-01
Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
2011 Annual Health Physics Report for the HEU transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2012-04-30
During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL's Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less
2008 Annual Health Physics Report for the HEU Transparency Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R.
2009-03-24
During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less
Medvedev, Oleg N; Turner-Stokes, Lynne; Ashford, Stephen; Siegert, Richard J
2018-02-28
To determine whether the UK Functional Assessment Measure (UK FIM+FAM) fits the Rasch model in stroke patients with complex disability and, if so, to derive a conversion table of Rasch-transformed interval level scores. The sample included a UK multicentre cohort of 1,318 patients admitted for specialist rehabilitation following a stroke. Rasch analysis was conducted for the 30-item scale including 3 domains of items measuring physical, communication and psychosocial functions. The fit of items to the Rasch model was examined using 3 different analytical approaches referred to as "pathways". The best fit was achieved in the pathway where responses from motor, communication and psychosocial domains were summarized into 3 super-items and where some items were split because of differential item functioning (DIF) relative to left and right hemisphere location (χ2 (10) = 14.48, p = 0.15). Re-scoring of items showing disordered thresholds did not significantly improve the overall model fit. The UK FIM+FAM with domain super-items satisfies expectations of the unidimensional Rasch model without the need for re-scoring. A conversion table was produced to convert the total scale scores into interval-level data based on person estimates of the Rasch model. The clinical benefits of interval-transformed scores require further evaluation.
The accompanying adult: authority to give consent in the UK.
Lal, Seema Madhur Lata; Parekh, Susan; Mason, Carol; Roberts, Graham
2007-05-01
Children may be accompanied by various people when attending for dental treatment. Before treatment is started, there is a legal requirement that the operator obtain informed consent for the proposed procedure. In the case of minors, the person authorized to give consent (parental responsibility) is usually a parent. To ascertain if accompanying persons of children attending the Department of Paediatric Dentistry at the Eastman Dental Hospital, London were empowered to give consent for the child's dental treatment. A total of 250 accompanying persons of children attending were selected, over a 6-month period. A questionnaire was used to establish whether the accompanying person(s) were authorized to give consent. The study showed that 12% of accompanying persons had no legal authority to give consent for the child's dental treatment. Clinicians need to be aware of the status of persons accompanying children to ensure valid consent is obtained.
David Price--Pioneer of digital ICP monitoring, neurosurgeon and teacher.
Czosnyka, Marek; Kirollos, Ramez; van Hille, Philip
2015-06-01
In early 1970s first personal desk-top computers started to be available in hospitals. Mr Price was one of the pioneers introducing his own software to identify Marmarou's model of CSF space during infusion studies to diagnose patients suffering from hydrocephalus. His closed-loop control system for infusion of mannitol to manage patients at risk of intracranial hypertension was designed in 1977. The system worked successfully for 10 years in Pinderfields Hospital in Wakefield, UK. In the middle 1980's he initiated international cooperation with Children's Health Centre in Poland in long-term computer-assisted monitoring and analysis of ICP. Software designed in a course of this cooperation paved the way for contemporary package of ICM+ (Intensive Care Monitor, University of Cambridge, UK). Our scientific portfolio from these years (1985-1995) contains hundreds of head injured patients with waveform ICP analysis, introduction of compensatory reserve index RAP, few highly cited papers. Now, we understand ICP much better thanks to David's personal passion and extremely friendly support.
The Challenge of Measuring UK Wealth Inequality in the 2000s†
Alvaredo, Facundo; Atkinson, Anthony B.; Morelli, Salvatore
2016-01-01
Abstract The concentration of personal wealth is now receiving a great deal of attention – after having been neglected for many years. One reason is the growing recognition that, in seeking explanations for rising income inequality, we need to look not only at wages and earned income but also at income from capital, particularly at the top of the distribution. In this paper, we use evidence from existing data sources to attempt to answer three questions: (i) What is the share of total personal wealth that is owned by the top 1 per cent, or the top 0.1 per cent? (ii) Is wealth much more unequally distributed than income? (iii) Is the concentration of wealth at the top increasing over time? The main conclusion of the paper is that the evidence about the UK concentration of wealth post‐2000 is seriously incomplete and significant investment in a variety of sources is necessary if we are to provide satisfactory answers to the three questions. PMID:27635106
Do children with reading delay benefit from the use of personal FM systems in the classroom?
Purdy, Suzanne C; Smart, Jennifer L; Baily, Melissa; Sharma, Mridula
2009-12-01
FM systems have been used to compensate for poor signal-to-noise ratios in classrooms. This study evaluates benefits of a 6-week trial of personal FM systems used during the school day for children with reading delay aged 6-11 years, using a randomized control design. Teachers and children completed the LIFE-UK questionnaire. Test-retest reliability of the LIFE-UK children's version was confirmed in a separate group of 18 children from the same school. The 23 children in the FM group had significantly improved teacher ratings, and the children's ratings of classroom listening for difficult situations were significantly better after the trial. These changes did not occur for the 23 control-group children. Most children (92%) commented positively about the FM after the trial. It is likely that a longer FM trial or a specific reading intervention combined with FM will be required for the benefits of enhanced listening to affect performance on standardized reading tests.
Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations
Mohammadyari, Parvin; Zehtabian, Mehdi; Sina, Sedigheh; Tavasoli, Ali Reza
2014-01-01
Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft‐versus‐host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 Elan was performed by several dosimeter methods including thermoluminescence dosimeters (TLD), PAGAT gel dosimetry, and Monte Carlo simulations using MCNP4C code. The gel dosimeter was put inside a glass phantom and the TL dosimeters were placed on its surface, and the phantom was then irradiated for 5 min and 27 sec. The dose values at each point inside the vials were obtained from the magnetic resonance imaging of the phantom. For Monte Carlo simulations, all components of the irradiator were simulated and the dose values in a fine cubical lattice were calculated using tally F6. This study shows that PAGAT gel dosimetry results are in close agreement with the results of TL dosimetry, Monte Carlo simulations, and the results given by the vendor, and the percentage difference between the different methods is less than 4% at different points inside the phantom. According to the results obtained in this study, PAGAT gel dosimetry is a reliable method for dosimetry of the blood irradiator. The major advantage of this kind of dosimetry is that it is capable of 3D dose calculation. PACS number: 87.53.Bn PMID:24423829
Dosimetry of ionising radiation in modern radiation oncology
NASA Astrophysics Data System (ADS)
Kron, Tomas; Lehmann, Joerg; Greer, Peter B.
2016-07-01
Dosimetry of ionising radiation is a well-established and mature branch of physical sciences with many applications in medicine and biology. In particular radiotherapy relies on dosimetry for optimisation of cancer treatment and avoidance of severe toxicity for patients. Several novel developments in radiotherapy have introduced new challenges for dosimetry with small and dynamically changing radiation fields being central to many of these applications such as stereotactic ablative body radiotherapy and intensity modulated radiation therapy. There is also an increasing awareness of low doses given to structures not in the target region and the associated risk of secondary cancer induction. Here accurate dosimetry is important not only for treatment optimisation but also for the generation of data that can inform radiation protection approaches in the future. The article introduces some of the challenges and highlights the interdependence of dosimetric calculations and measurements. Dosimetric concepts are explored in the context of six application fields: reference dosimetry, small fields, low dose out of field, in vivo dosimetry, brachytherapy and auditing of radiotherapy practice. Recent developments of dosimeters that can be used for these purposes are discussed using spatial resolution and number of dimensions for measurement as sorting criteria. While dosimetry is ever evolving to address the needs of advancing applications of radiation in medicine two fundamental issues remain: the accuracy of the measurement from a scientific perspective and the importance to link the measurement to a clinically relevant question. This review aims to provide an update on both of these.
Racism, mental illness and social support in the UK.
Chakraborty, Apu T; McKenzie, Kwame J; Hajat, Shakoor; Stansfeld, Stephen A
2010-12-01
The difference in risk of mental illness in UK ethnic minorities may be related to a balance between specific risk factors such as racial discrimination and mediating factors such as social support. We investigated whether social support from friends or relatives reduces the cross-sectional association between perceived racism and the risk of mental illness in an ethnic minority group. We conducted secondary analyses of nationally representative community samples of five UK ethnic minority groups (EMPIRIC dataset; n = 4,281) using multiple regression techniques. We found that the associations between perceived racism, common mental disorder and potentially psychotic symptoms were mainly independent of social support as measured by the number of close persons and their proximity to the individual. Social support when measured in this way does not mediate the associations between perceived racism and mental ill health in this population-based sample.
Copper disinfection ban causes storm.
Lester, Alan
2013-05-01
Since 1 February this year, under the EU's Biocidal Products Directive, it has been illegal to sell or use water treatment systems that use elemental copper, a practice employed historically by a significant number of UK healthcare facilities to combat Legionella. Alan Lester, managing director of specialist supplier of 'environmentally-friendly' water treatment systems, Advanced Hydro, says the ban has caused 'a storm of giant proportion,' with advocates of copper ion-based treatment systems arguing that this disinfection method dates back 3,000 years to Egyptian times, making it an 'undoubtedly proven' technology. Here he explains why the ban came into force, considers why the UK's Health and Safety Executive (HSE) is seeking a derogation, looks at the ban's likely impact, and gives a personal viewpoint on the 'pros and cons' of some of the alternative treatment technologies, including a titanium dioxide-based system marketed by Advanced Hydro itself in the UK.
How do directors of public health perceive leadership?
McAreav, M J; Alimo-Metcalfe, B; Connelly, J
2001-01-01
This study examines how directors of public health (DsPH) perceive effective leadership. Kelly's repertory grid technique is used. A total of 13 out of a possible 14 DsPH in one NHS region of England were interviewed. Qualitative and quantitative analysis were carried out. The findings show that male DsPH (n = 8) rate their leadership ability more highly than do female DsPH (n = 5). Qualitative analysis produced a number of categories of constructs, some of which are perceived to be indicative of effective leadership, these being "working for others", "personal attributes", "vision and innovation" and "courage and integrity" Some categories appear to be applicable only to the UK (or to public health) and not to the existing dominant US models of leadership. In general, DsPH perceptions of effective leadership converge with current theories; most specifically the UK-based theories. This study therefore refutes any simple extrapolation of US theories of leadership to UK health organisations.
Assessment of road users' elemental carbon personal exposure levels, London, UK
NASA Astrophysics Data System (ADS)
Adams, H. S.; Nieuwenhuijsen, M. J.; Colvile, R. N.; Older, M. J.; Kendall, M.
Little is known about particulate elemental carbon (EC) personal exposure levels, a key component of diesel exhaust, specifically in transport microenvironments. A method utilizing the optical properties of EC particles has been applied to personal exposure measurement filter samples. In a series of field studies carried out in London, UK, during 1999-2000 over 400 fine particle (PM 2.5) personal exposure level measurements were taken for journeys in bicycle, bus, car and underground rail transport microenvironments, along three main fixed routes. The particulate EC contribution to the PM 2.5 personal exposure was assessed indirectly by means of an optical technique and with the development and use of a size fraction specific and site-specific calibration curve. In this first EC personal exposure study of transport users geometric mean exposure levels in the summer field campaign were 11.2 μg m -3 (GSD=2.7) for cyclists, 13.6 μg m -3 (GSD=1.9) for bus passengers and 21.6 μg m -3 (GSD=2.1) for car drivers; corresponding exposure levels in the winter were 16.4 μg m -3 (GSD=1.8), 18.6 μg m -3 (GSD=2.3) and 27.3 μg m -3 (GSD=2.0), respectively. EC/PM 2.5 ratios were approximately 0.5-0.6 for bicycle and bus modes and 0.7-0.8 for the car mode. EC/PM 2.5 ratios for different routes ranged from approximately 0.7 for Route 1 to 0.4 for Route 3. Cyclists had the lowest exposure to EC, and car occupants the highest exposure. A large difference in exposure levels between a central high traffic density route and the other less central routes was observed. Particulate EC was a very significant proportion of the total PM 2.5 personal exposure and EC personal exposure levels were considerably higher than reported fixed site monitor EC concentrations.
Combined effects of noise and shift work on fatigue as a function of age.
Saremi, Mahnaz; Rohmer, Odile; Burgmeier, André; Bonnefond, Anne; Muzet, Alain; Tassi, Patricia
2008-01-01
The study was conducted to analyse possible interactions between noise and shift work, and fatigue as a function of age. In a large questionnaire survey, we assessed personal and environmental risk factors related to fatigue. Noise exposure at work (L(Aeq, 8hr)) was measured with personal noise dosimetry. The sample included 254 day and shift workers, and was divided into 2 age groups (<40- and >40-year-olds). Noise exposure had a main effect on fatigue. The highest noise exposure resulted in an increase in the fatigue level of older shift workers. The quantity of sleep mainly depended on the type of shift and age. Our data suggest that the most important factor generating fatigue could be related to industrial noise exposure, a factor which seems to aggravate work-related fatigue generated in a synergic manner by shift work and ageing. Senior workers should be prevented from cumulating those occupational stressors.
Lahaye, T; Chau, Q; Ménard, S; Lacoste, V; Muller, H; Luszik-Bhadra, M; Reginatto, M; Bruguier, P
2006-01-01
This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources ((241)AmBe; (252)Cf; (252)Cf(D(2)O)\\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory.
2016-01-01
Objective: Obesity has been shown to increase risk of depression. Persons with obesity experience discrimination because of their body weight. Across 3 studies, we tested for the first time whether experiencing (perceived) weight-based discrimination explains why obesity is prospectively associated with increases in depressive symptoms. Method: Data from 3 studies, including the English Longitudinal Study of Ageing (2008/2009–2012/2013), the Health and Retirement Study (2006/2008–2010/2012), and Midlife in the United States (1995/1996–2004/2005), were used to examine associations between obesity, perceived weight discrimination, and depressive symptoms among 20,286 U.S. and U.K. adults. Results: Across all 3 studies, Class II and III obesity were reliably associated with increases in depressive symptoms from baseline to follow-up. Perceived weight-based discrimination predicted increases in depressive symptoms over time and mediated the prospective association between obesity and depressive symptoms in all 3 studies. Persons with Class II and III obesity were more likely to report experiencing weight-based discrimination, and this explained approximately 31% of the obesity-related increase in depressive symptoms on average across the 3 studies. Conclusion: In U.S. and U.K. samples, the prospective association between obesity (defined using body mass index) and increases in depressive symptoms in adulthood may in part be explained by perceived weight discrimination. PMID:27748611
Allodji, Rodrigue S; Schwartz, Boris; Diallo, Ibrahima; Agbovon, Césaire; Laurier, Dominique; de Vathaire, Florent
2015-08-01
Analyses of the Life Span Study (LSS) of Japanese atomic bombing survivors have routinely incorporated corrections for additive classical measurement errors using regression calibration. Recently, several studies reported that the efficiency of the simulation-extrapolation method (SIMEX) is slightly more accurate than the simple regression calibration method (RCAL). In the present paper, the SIMEX and RCAL methods have been used to address errors in atomic bomb survivor dosimetry on solid cancer and leukaemia mortality risk estimates. For instance, it is shown that using the SIMEX method, the ERR/Gy is increased by an amount of about 29 % for all solid cancer deaths using a linear model compared to the RCAL method, and the corrected EAR 10(-4) person-years at 1 Gy (the linear terms) is decreased by about 8 %, while the corrected quadratic term (EAR 10(-4) person-years/Gy(2)) is increased by about 65 % for leukaemia deaths based on a linear-quadratic model. The results with SIMEX method are slightly higher than published values. The observed differences were probably due to the fact that with the RCAL method the dosimetric data were partially corrected, while all doses were considered with the SIMEX method. Therefore, one should be careful when comparing the estimated risks and it may be useful to use several correction techniques in order to obtain a range of corrected estimates, rather than to rely on a single technique. This work will enable to improve the risk estimates derived from LSS data, and help to make more reliable the development of radiation protection standards.
Taheri, M; Jafarizadeh, M; Baradaran, S; Zainali, Gh
2006-12-01
Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.
Kumwenda, Ben; Dowell, Jon; Husbands, Adrian
2013-07-01
The assessment of non-academic achievements through the personal statement remains part of the selection process at most UK medical and dental schools. Such statement offers applicants an opportunity to highlight their non-academic achievements, but the highly competitive nature of the process may tempt them to exaggerate their accomplishments. The challenge is that selectors cannot discern applicants' exaggerated claims from genuine accounts and the system risks preferentially selecting dishonest applicants. To explore the level and perception of deception on UCAS personal statements among applicants to medical and dental schools. To investigate the association between attitudes towards deception and various other demographic variables and cognitive ability via the UKCAT. An online survey was completed with first year students from six UK medical schools and one dental school. Questionnaire items were classified into three categories involving individual acts, how they suspect their peers behave, and overall perceptions of personal statements to influence the selection process. Descriptive statistics were used to investigate responses to questionnaire items. t-Tests were used to investigate the relationship between items, demographic variables and cognitive ability. Candidates recognized that putting fraudulent information or exaggerating one's experience on UCAS personal statement was dishonest; however there is a widespread belief that their peers do it. Female respondents and those with a higher UKCAT score were more likely to condemn deceptive practices. The existing selection process is open to abuse and may benefit dishonest applicants. Admission systems should consider investing in systems that can pursue traceable information that applicants provide, and nullify the application should it contain fraudulent information.
A comparison of two methods of in vivo dosimetry for a high energy neutron beam.
Blake, S W; Bonnett, D E; Finch, J
1990-06-01
Two methods of in vivo dosimetry have been compared in a high energy neutron beam. These were activation dosimetry and thermoluminescence dosimetry (TLD). Their suitability was determined by comparison with estimates of total dose, obtained using a tissue equivalent ionization chamber. Measurements were made on the central axis and a profile of a 10 x 10 cm square field and also behind a shielding block in order to simulate conditions of clinical use. The TLD system was found to provide the best estimate of total dose.
Radiation dosimetry for quality control of food preservation and disinfestation
NASA Astrophysics Data System (ADS)
McLaughlin, W. L.; Miller, A.; Uribe, R. M.
In the use of x and gamma rays and scanned electron beams to extend the shelf life of food by delay of sprouting and ripening, killing of microbes, and control of insect population, quality assurance is provided by standardized radiation dosimetry. By strategic placement of calibrated dosimeters that are sufficiently stable and reproducible, it is possible to monitor minimum and maximum radiation absorbed dose levels and dose uniformity for a given processed foodstuff. The dosimetry procedure is especially important in the commisioning of a process and in making adjustments of process parameters (e.g. conveyor speed) to meet changes that occur in product and source parameters (e.g. bulk density and radiation spectrum). Routine dosimetry methods and certain corrections of dosimetry data may be selected for the radiations used in typical food processes.
NASA Astrophysics Data System (ADS)
Soares, Christopher
2006-03-01
In 2004 a new work item proposal (NWIP) was accepted by the International Organization for Standardization (ISO) Technical Committee 85 (TC85 -- Nuclear Energy), Subcommittee 2 (Radiation Protection) for the development of a standard for the clinical dosimetry of beta radiation sources used for brachytherapy. To develop this standard, a new Working Group (WG 22 - Ionizing Radiation Dosimetry and Protocols in Medical Applications) was formed. The standard is based on the work of an ad-hoc working group initiated by the Dosimetry task group of the Deutsches Insitiut für Normung (DIN). Initially the work was geared mainly towards the needs of intravascular brachytherapy, but with the decline of this application, more focus has been placed on the challenges of accurate dosimetry for the concave eye plaques used to treat ocular melanoma. Guidance is given for dosimetry formalisms, reference data to be used, calibrations, measurement methods, modeling, uncertainty determinations, treatment planning and reporting, and clinical quality control. The document is currently undergoing review by the ISO member bodies for acceptance as a Committee Draft (CD) with publication of the final standard expected by 2007. There are opportunities for other ISO standards for medical dosimetry within the framework of WG22.
Specific issues in small animal dosimetry and irradiator calibration
Yoshizumi, Terry; Brady, Samuel L.; Robbins, Mike E.; Bourland, J. Daniel
2013-01-01
Purpose In response to the increased risk of radiological terrorist attack, a network of Centers for Medical Countermeasures against Radiation (CMCR) has been established in the United States, focusing on evaluating animal model responses to uniform, relatively homogenous whole- or partial-body radiation exposures at relatively high dose rates. The success of such studies is dependent not only on robust animal models but on accurate and reproducible dosimetry within and across CMCR. To address this issue, the Education and Training Core of the Duke University School of Medicine CMCR organised a one-day workshop on small animal dosimetry. Topics included accuracy in animal dosimetry accuracy, characteristics and differences of cesium-137 and X-ray irradiators, methods for dose measurement, and design of experimental irradiation geometries for uniform dose distributions. This paper summarises the information presented and discussed. Conclusions Without ensuring accurate and reproducible dosimetry the development and assessment of the efficacy of putative countermeasures will not prove successful. Radiation physics support is needed, but is often the weakest link in the small animal dosimetry chain. We recommend: (i) A user training program for new irradiator users, (ii) subsequent training updates, and (iii) the establishment of a national small animal dosimetry center for all CMCR members. PMID:21961967
Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance.
Narayanasamy, Ganesh; Zalman, Travis; Ha, Chul S; Papanikolaou, Niko; Stathakis, Sotirios
2015-05-08
The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose comparisons in a plane, Dosimetry Check system produces isodose lines and dose-volume histograms based on the planning CT images. By exporting the dose distribution from the treatment planning system into the Dosimetry Check system, one is able to make a direct comparison between the calculated dose and the planned dose. The versatility of the software is evaluated with respect to the two IMRT techniques - step and shoot and volumetric arc therapy. The system analyzed measurements made using EPID, PTW seven29, and IBA MatriXX, and an intercomparison study was performed. Plans from patients previously treated at our institution with treated anatomical site on brain, head & neck, liver, lung, and prostate were analyzed using Dosimetry Check system for any anatomical site dependence. We have recommendations and possible precautions that may be necessary to ensure proper QA with the Dosimetry Check system.
Establishing the Competence of Outdoor Training Staff.
ERIC Educational Resources Information Center
Everard, Bertie
1997-01-01
The United Kingdom lacks a framework of nationally recognized professional qualifications for outdoor trainers and facilitators. Various definitions of competence are examined, and suggestions are offered for improving approaches to establishing staff competence. Includes a model of personal development dimensions, and compares U.K. and U.S.…
Exploring Good Character and Citizenship in England
ERIC Educational Resources Information Center
Arthur, James; Harrison, Tom
2012-01-01
Citizenship, character and the virtues that constitute both are increasingly concerns of public policy in the UK. This article understands character to encompass the morally valuable, reason-response and education part of personality, and understands virtues as states of character concerned with praiseworthy feelings and conduct in specific…
Metalearning Capacity and Threshold Concept Engagement
ERIC Educational Resources Information Center
Ward, Sophie C.; Meyer, Jan H. F.
2010-01-01
This study aims to further our understanding of metalearning activity through the analysis of qualitative data gathered from 370 first-year microeconomics students in three UK universities. The students were asked to produce undirected reflective essays in response to a personal "learning profile" generated before, and after, the…
CGAT: a model for immersive personalized training in computational genomics
Sims, David; Ponting, Chris P.
2016-01-01
How should the next generation of genomics scientists be trained while simultaneously pursuing high quality and diverse research? CGAT, the Computational Genomics Analysis and Training programme, was set up in 2010 by the UK Medical Research Council to complement its investment in next-generation sequencing capacity. CGAT was conceived around the twin goals of training future leaders in genome biology and medicine, and providing much needed capacity to UK science for analysing genome scale data sets. Here we outline the training programme employed by CGAT and describe how it dovetails with collaborative research projects to launch scientists on the road towards independent research careers in genomics. PMID:25981124
Laskaratos, Faidon-Marios; Gkotsi, Despoina; Panteliou, Eleftheria
2014-01-01
This paper represents a systematic evaluation of the Core Medical Training Curriculum in the UK. The authors critically review the curriculum from a medical education perspective based mainly on the medical education literature as well as their personal experience of this curriculum. They conclude in practical recommendations and suggestions which, if adopted, could improve the design and implementation of this postgraduate curriculum. The systematic evaluation approach described in this paper is transferable to the evaluation of other undergraduate or postgraduate curricula, and could be a helpful guide for medical teachers involved in the delivery and evaluation of any medical curriculum.
Is Smoking Behavior Culturally Determined? Evidence from British Immigrants*
Lillard, Dean R.
2015-01-01
We exploit migration patterns from the UK to Australia and the US to investigate whether a person's decision to smoke is determined by culture. For each country, we use retrospective data to describe individual smoking trajectories over the life-course. For the UK, we use these trajectories to measure culture by cohort and cohort-age, and more accurately relative to the extant literature. Our proxy predicts smoking participation of second-generation British immigrants but not that of non-British immigrants and natives. Researchers can apply our strategy to estimate culture effects on other outcomes when retrospective or longitudinal data are available. PMID:25620826
NASA Astrophysics Data System (ADS)
Williamson, Jeffrey F.
2006-09-01
This paper briefly reviews the evolution of brachytherapy dosimetry from 1900 to the present. Dosimetric practices in brachytherapy fall into three distinct eras: During the era of biological dosimetry (1900-1938), radium pioneers could only specify Ra-226 and Rn-222 implants in terms of the mass of radium encapsulated within the implanted sources. Due to the high energy of its emitted gamma rays and the long range of its secondary electrons in air, free-air chambers could not be used to quantify the output of Ra-226 sources in terms of exposure. Biological dosimetry, most prominently the threshold erythema dose, gained currency as a means of intercomparing radium treatments with exposure-calibrated orthovoltage x-ray units. The classical dosimetry era (1940-1980) began with successful exposure standardization of Ra-226 sources by Bragg-Gray cavity chambers. Classical dose-computation algorithms, based upon 1-D buildup factor measurements and point-source superposition computational algorithms, were able to accommodate artificial radionuclides such as Co-60, Ir-192, and Cs-137. The quantitative dosimetry era (1980- ) arose in response to the increasing utilization of low energy K-capture radionuclides such as I-125 and Pd-103 for which classical approaches could not be expected to estimate accurate correct doses. This led to intensive development of both experimental (largely TLD-100 dosimetry) and Monte Carlo dosimetry techniques along with more accurate air-kerma strength standards. As a result of extensive benchmarking and intercomparison of these different methods, single-seed low-energy radionuclide dose distributions are now known with a total uncertainty of 3%-5%.
Vestad, Tor Arne; Malinen, Eirik; Olsen, Dag Rune; Hole, Eli Olaug; Sagstuen, Einar
2004-10-21
Solid-state radiation dosimetry by electron paramagnetic resonance (EPR) spectroscopy and thermoluminescence (TL) was utilized for the determination of absorbed doses in the range of 0.5-2.5 Gy. The dosimeter materials used were lithium formate and lithium fluoride (TLD-100 rods) for EPR dosimetry and TL dosimetry, respectively. 60Co gamma-rays and 4, 6, 10 and 15 MV x-rays were employed. The main objectives were to compare the variation in dosimeter reading of the respective dosimetry systems and to determine the photon energy dependence of the two dosimeter materials. The EPR dosimeter sensitivity was constant over the dose range in question, while the TL sensitivity increased by more than 5% from 0.5 to 2.5 Gy, thus displaying a supralinear dose response. The average relative standard deviation in the dosimeter reading per dose was 3.0% and 1.2% for the EPR and TL procedures, respectively. For EPR dosimeters, the relative standard deviation declined significantly from 4.3% to 1.1% over the dose range in question. The dose-to-water energy response for the megavoltage x-ray beams relative to 60Co gamma-rays was in the range of 0.990-0.979 and 0.984-0.962 for lithium formate and lithium fluoride, respectively. The results show that EPR dosimetry with lithium formate provides dose estimates with a precision comparable to that of TL dosimetry (using lithium fluoride) for doses above 2 Gy, and that lithium formate is slightly less dependent on megavoltage photon beam energy than lithium fluoride.
NASA Astrophysics Data System (ADS)
Vestad, Tor Arne; Malinen, Eirik; Rune Olsen, Dag; Olaug Hole, Eli; Sagstuen, Einar
2004-10-01
Solid-state radiation dosimetry by electron paramagnetic resonance (EPR) spectroscopy and thermoluminescence (TL) was utilized for the determination of absorbed doses in the range of 0.5-2.5 Gy. The dosimeter materials used were lithium formate and lithium fluoride (TLD-100 rods) for EPR dosimetry and TL dosimetry, respectively. 60Co ggr-rays and 4, 6, 10 and 15 MV x-rays were employed. The main objectives were to compare the variation in dosimeter reading of the respective dosimetry systems and to determine the photon energy dependence of the two dosimeter materials. The EPR dosimeter sensitivity was constant over the dose range in question, while the TL sensitivity increased by more than 5% from 0.5 to 2.5 Gy, thus displaying a supralinear dose response. The average relative standard deviation in the dosimeter reading per dose was 3.0% and 1.2% for the EPR and TL procedures, respectively. For EPR dosimeters, the relative standard deviation declined significantly from 4.3% to 1.1% over the dose range in question. The dose-to-water energy response for the megavoltage x-ray beams relative to 60Co ggr-rays was in the range of 0.990-0.979 and 0.984-0.962 for lithium formate and lithium fluoride, respectively. The results show that EPR dosimetry with lithium formate provides dose estimates with a precision comparable to that of TL dosimetry (using lithium fluoride) for doses above 2 Gy, and that lithium formate is slightly less dependent on megavoltage photon beam energy than lithium fluoride.
Innovation and the future of advanced dosimetry: 2D to 5D
NASA Astrophysics Data System (ADS)
Oldham, Mark
2017-05-01
Recent years have witnessed a remarkable evolution in the techniques, capabilities and applications of 3D dosimetry. Initially the goal was simple: to innovate new techniques capable of comprehensively measuring and verifying exquisitely intricate dose distributions from a paradigm changing emerging new therapy, IMRT. Basic questions emerged: how well were treatment planning systems modelling the complex delivery, and how could treatments be verified for safe use on patients? Since that time, equally significant leaps of innovation have continued in the technology of treatment delivery. In addition, clinical practice has been transformed by the addition of on-board imaging capabilities, which tend to hypo-fractionation strategies and margin reduction. The net result is a high stakes treatment setting where the clinical morbidity of any unintended treatment deviation is exacerbated by the combination of highly conformal dose distributions given with reduced margins with fractionation regimens unfriendly to healthy tissue. Not surprisingly this scenario is replete with challenges and opportunities for new and improved dosimetry systems. In particular tremendous interest exists in comprehensive 3D dosimetry systems, and systems that can resolve the dose in moving structures (4D) and even in deforming structures (5D). Despite significant progress in the capability of multi-dimensional dosimetry systems, it is striking that true 3D dosimetry systems are today largely found in academic institutions or specialist clinics. The reasons will be explored. We will highlight innovations occurring both in treatment delivery and in advanced dosimetry methods designed to verify them, and explore current and future opportunities for advanced dosimetry tools in clinical practice and translational research.
This report summarizes the status of specific inhalation dosimetry procedures for gases as outlined in U.S. EPA’s 1994 Methods for Derivation of Inhalation Reference Concentrations and Applications of Inhalation Dosimetry (U.S. EPA 1994) and reviews recent scientific advances in...
NASA Astrophysics Data System (ADS)
Pogue, Brian W.; Davis, Scott C.; Kanick, Stephen C.; Maytin, Edward V.; Pereira, Stephen P.; Palanisami, Akilan; Hasan, Tayyaba
2016-03-01
Photodynamic therapy can be a highly complex treatment with more than one parameter to control, or in some cases it is easily implemented with little control other than prescribed drug and light values. The role of measured dosimetry as related to clinical adoption has not been as successful as it could have been, and part of this may be from the conflicting goals of advocating for as many measurements as possible for accurate control, versus companies and clinical adopters advocating for as few measurements as possible, to keep it simple. An organized approach to dosimetry selection is required, which shifts from mechanistic measurements in pre-clinical and early phase I trials, towards just those essential dose limiting measurements and a focus on possible surrogate measures in phase II/III trials. This essential and surrogate approach to dosimetry should help successful adoption of clinical PDT if successful. The examples of essential dosimetry points and surrogate dosimetry tools which might be implemented in phase II and higher trials are discussed for solid tissue PDT with verteporfin and skin lesion treatment with aminolevulinc acid.
Monte Carlo simulations in radiotherapy dosimetry.
Andreo, Pedro
2018-06-27
The use of the Monte Carlo (MC) method in radiotherapy dosimetry has increased almost exponentially in the last decades. Its widespread use in the field has converted this computer simulation technique in a common tool for reference and treatment planning dosimetry calculations. This work reviews the different MC calculations made on dosimetric quantities, like stopping-power ratios and perturbation correction factors required for reference ionization chamber dosimetry, as well as the fully realistic MC simulations currently available on clinical accelerators, detectors and patient treatment planning. Issues are raised that include the necessity for consistency in the data throughout the entire dosimetry chain in reference dosimetry, and how Bragg-Gray theory breaks down for small photon fields. Both aspects are less critical for MC treatment planning applications, but there are important constraints like tissue characterization and its patient-to-patient variability, which together with the conversion between dose-to-water and dose-to-tissue, are analysed in detail. Although these constraints are common to all methods and algorithms used in different types of treatment planning systems, they make uncertainties involved in MC treatment planning to still remain "uncertain".
Chemical dosimetry system for criticality accidents.
Miljanić, Saveta; Ilijas, Boris
2004-01-01
Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.
Woda, Clemens; Bassinet, Céline; Trompier, François; Bortolin, Emanuela; Della Monaca, Sara; Fattibene, Paola
2009-01-01
The increasing risk of a mass casualty scenario following a large scale radiological accident or attack necessitates the development of appropriate dosimetric tools for emergency response. Luminescence dosimetry has been reliably applied for dose reconstruction in contaminated settlements for several decades and recent research into new materials carried close to the human body opens the possibility of estimating individual doses for accident and emergency dosimetry using the same technique. This paper reviews the luminescence research into materials useful for accident dosimetry and applications in retrospective dosimetry. The properties of the materials are critically discussed with regard to the requirements for population triage. It is concluded that electronic components found within portable electronic devices, such as e.g. mobile phones, are at present the most promising material to function as a fortuitous dosimeter in an emergency response.
Retrospective dosimetry analyses of reactor vessel cladding samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenwood, L. R.; Soderquist, C. Z.; Fero, A. H.
2011-07-01
Reactor pressure vessel cladding samples for Ringhals Units 3 and 4 in Sweden were analyzed using retrospective reactor dosimetry techniques. The objective was to provide the best estimates of the neutron fluence for comparison with neutron transport calculations. A total of 51 stainless steel samples consisting of chips weighing approximately 100 to 200 mg were removed from selected locations around the pressure vessel and were sent to Pacific Northwest National Laboratory for analysis. The samples were fully characterized and analyzed for radioactive isotopes, with special interest in the presence of Nb-93m. The RPV cladding retrospective dosimetry results will be combinedmore » with a re-evaluation of the surveillance capsule dosimetry and with ex-vessel neutron dosimetry results to form a comprehensive 3D comparison of measurements to calculations performed with 3D deterministic transport code. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, G.A.
2011-07-01
Document available in abstract form only, full text of document follows: The dosimetry from the H. B. Robinson Unit 2 Pressure Vessel Benchmark is analyzed with a suite of Westinghouse-developed codes and data libraries. The radiation transport from the reactor core to the surveillance capsule and ex-vessel locations is performed by RAPTOR-M3G, a parallel deterministic radiation transport code that calculates high-resolution neutron flux information in three dimensions. The cross-section library used in this analysis is the ALPAN library, an Evaluated Nuclear Data File (ENDF)/B-VII.0-based library designed for reactor dosimetry and fluence analysis applications. Dosimetry is evaluated with the industry-standard SNLRMLmore » reactor dosimetry cross-section data library. (authors)« less
Physical employment standards for U.K. fire and rescue service personnel.
Blacker, S D; Rayson, M P; Wilkinson, D M; Carter, J M; Nevill, A M; Richmond, V L
2016-01-01
Evidence-based physical employment standards are vital for recruiting, training and maintaining the operational effectiveness of personnel in physically demanding occupations. (i) Develop criterion tests for in-service physical assessment, which simulate the role-related physical demands of UK fire and rescue service (UK FRS) personnel. (ii) Develop practical physical selection tests for FRS applicants. (iii) Evaluate the validity of the selection tests to predict criterion test performance. Stage 1: we conducted a physical demands analysis involving seven workshops and an expert panel to document the key physical tasks required of UK FRS personnel and to develop 'criterion' and 'selection' tests. Stage 2: we measured the performance of 137 trainee and 50 trained UK FRS personnel on selection, criterion and 'field' measures of aerobic power, strength and body size. Statistical models were developed to predict criterion test performance. Stage 3: matter experts derived minimum performance standards. We developed single person simulations of the key physical tasks required of UK FRS personnel as criterion and selection tests (rural fire, domestic fire, ladder lift, ladder extension, ladder climb, pump assembly, enclosed space search). Selection tests were marginally stronger predictors of criterion test performance (r = 0.88-0.94, 95% Limits of Agreement [LoA] 7.6-14.0%) than field test scores (r = 0.84-0.94, 95% LoA 8.0-19.8%) and offered greater face and content validity and more practical implementation. This study outlines the development of role-related, gender-free physical employment tests for the UK FRS, which conform to equal opportunities law. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rosser, K E
1998-11-01
This paper evaluates the characteristics of ionization chambers for the measurement of absorbed dose to water for medium-energy x-rays. The values of the chamber correction factor, k(ch), used in the IPEMB code of practice for the UK secondary standard (NE2561/NE2611) ionization chamber are derived and their constituent factors examined. The comparison of the chambers' responses in air revealed that of the chambers tested only the NE2561, NE2571 and NE2505 exhibit a flat (within 5%) energy response in air. Under no circumstances should the NACP, Sanders electron chamber, or any chamber that has a wall made of high atomic number material, be used for medium-energy x-ray dosimetry. The measurements in water reveal that a chamber that has a substantial housing, such as the PTW Grenz chamber, should not be used to measure absorbed dose to water in this energy range. The value of k(ch) for an NE2561 chamber was determined by measuring the absorbed dose to water and comparing it with that for an NE2571 chamber, for which k(ch) data have been published. The chamber correction factor varies from 1.023 +/- 0.03 to 1.018 +/- 0.001 for x-ray beams with HVL between 0.15 and 4 mm Cu. The values agree with that for an NE2571 chamber within the experimental uncertainty. The corrections due to the stem, waterproof sleeve and replacement of the phantom material by the chamber for an NE2561 chamber are described.
NASA Astrophysics Data System (ADS)
Palmans, Hugo; Nafaa, Laila; de Patoul, Nathalie; Denis, Jean-Marc; Tomsej, Milan; Vynckier, Stefaan
2003-05-01
New codes of practice for reference dosimetry in clinical high-energy photon and electron beams have been published recently, to replace the air kerma based codes of practice that have determined the dosimetry of these beams for the past twenty years. In the present work, we compared dosimetry based on the two most widespread absorbed dose based recommendations (AAPM TG-51 and IAEA TRS-398) with two air kerma based recommendations (NCS report-5 and IAEA TRS-381). Measurements were performed in three clinical electron beam energies using two NE2571-type cylindrical chambers, two Markus-type plane-parallel chambers and two NACP-02-type plane-parallel chambers. Dosimetry based on direct calibrations of all chambers in 60Co was investigated, as well as dosimetry based on cross-calibrations of plane-parallel chambers against a cylindrical chamber in a high-energy electron beam. Furthermore, 60Co perturbation factors for plane-parallel chambers were derived. It is shown that the use of 60Co calibration factors could result in deviations of more than 2% for plane-parallel chambers between the old and new codes of practice, whereas the use of cross-calibration factors, which is the first recommendation in the new codes, reduces the differences to less than 0.8% for all situations investigated here. The results thus show that neither the chamber-to-chamber variations, nor the obtained absolute dose values are significantly altered by changing from air kerma based dosimetry to absorbed dose based dosimetry when using calibration factors obtained from the Laboratory for Standard Dosimetry, Ghent, Belgium. The values of the 60Co perturbation factor for plane-parallel chambers (katt . km for the air kerma based and pwall for the absorbed dose based codes of practice) that are obtained from comparing the results based on 60Co calibrations and cross-calibrations are within the experimental uncertainties in agreement with the results from other investigators.
TH-A-204-00: Key Dosimetry Data - Impact of New ICRU Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair inmore » dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV xrays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.« less
TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seltzer, S.
The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair inmore » dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.« less
Graduates' Employment and the Discourse of Employability: A Critical Analysis
ERIC Educational Resources Information Center
Moreau, Marie-Pierre; Leathwood, Carole
2006-01-01
In a context of considerable changes in the labour market and higher education sector in the UK, a discourse of employability has become increasingly dominant. Universities are urged to ensure that they produce "employable" graduates, and graduates themselves are exhorted to continually develop their personal skills, qualities and…
Gender & Education Association: A Case Study in Feminist Education?
ERIC Educational Resources Information Center
David, Miriam E.
2015-01-01
This article focuses on feminist activist academics who were instrumental in creating the UK Gender & Education Association at the turn of the twenty-first century. Drawing on my own intellectual biography (David, M. E. 2003. "Personal and Political: Feminisms, Sociology and Family Lives" Stoke-on-Trent. Trentham Books.) linked to…
ERIC Educational Resources Information Center
Humphries, Chris
2009-01-01
Today, people are facing unparalleled and unpredictable challenges. After 15 years of growth, people are in a global recession that may be the deepest for 75 years. Unemployment is rising, and thousands of people throughout the UK are suffering the very personal tragedy of losing their jobs. Certainty is a commodity in even shorter supply than…
ERIC Educational Resources Information Center
Falconer, Emily; Taylor, Yvette
2017-01-01
This article addresses the negotiation of "queer religious" student identities in UK higher education. The "university experience" has generally been characterised as a period of intense transformation and self-exploration, with complex and overlapping personal and social influences significantly shaping educational spaces,…
Transactional Analysis in the Classroom, Staffroom and Beyond
ERIC Educational Resources Information Center
Barrow, Giles
2015-01-01
The author considers the application of transactional analysis (TA) in the field of education. Initially, the focus is on the use of TA in reducing conflict in the classroom and staffroom before offering observations about its broader relevance to contemporary UK schooling. Concepts covered include the egostate model of personality, functional…
An Action Research Project Exploring the Psychology Curriculum and Transitions to Employment
ERIC Educational Resources Information Center
McMurray, Isabella; Roberts, Pat; Robertson, Ian; Teoh, Kevin
2011-01-01
Within the UK, traditional subject-specific areas are increasingly being complemented by the provision of opportunities to foster students' personal development planning as an aide to support their future employment and lifelong learning. This paper describes an action research project which examined employability skills within a psychology…
New Approaches to Technology in HE Management
ERIC Educational Resources Information Center
Cobb, Chris
2012-01-01
Most UK universities can trace their current management information systems back to significant investments made in the 1990s, largely fuelled by concerns about the millenium bug and a change from character interfaces to graphical user interfaces following the introduction of the personal computer. It was during this period that institutions also…
The Mayak Worker Dosimetry System (Mwds-2013): An Introduction to The Documentation
Napier, B. A.
2017-03-17
The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013. Here, this introduction outlines the logic and general content of the series of articles presented in this issue of Radiation Protection Dosimetry. The articles summarize the models, describe the basis for most of the key decisions made in developing the models and present an overview of the results.
Dosimetry analyses of the Ringhals 3 and 4 reactor pressure vessels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulesza, J.A.; Fero, A.H.; Rouden, J.
2011-07-01
A comprehensive series of neutron dosimetry measurements consisting of surveillance capsules, reactor pressure vessel cladding samples, and ex-vessel neutron dosimetry has been analyzed and compared to the results of three-dimensional, cycle-specific neutron transport calculations for the Ringhals Unit 3 and Unit 4 reactors in Sweden. The comparisons show excellent agreement between calculations and measurements. The measurements also demonstrate that it is possible to perform retrospective dosimetry measurements using the {sup 93}Nb (n,n') {sup 93m}Nb reaction on samples of 18-8 austenitic stainless steel with only trace amounts of elemental niobium. (authors)
The Mayak Worker Dosimetry System (Mwds-2013): An Introduction to The Documentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Napier, B. A.
The reconstruction of radiation doses to Mayak Production Association workers in central Russia supports radiation epidemiological studies for the U.S.-Russian Joint Coordinating Committee on Radiation Effects Research. The most recent version of the dosimetry was performed with the Mayak Worker Dosimetry System-2013. Here, this introduction outlines the logic and general content of the series of articles presented in this issue of Radiation Protection Dosimetry. The articles summarize the models, describe the basis for most of the key decisions made in developing the models and present an overview of the results.
Holtmann, B; Grosser, S; Lagisz, M; Johnson, S L; Santos, E S A; Lara, C E; Robertson, B C; Nakagawa, S
2016-02-01
Quantifying the variation in behaviour-related genes within and between populations provides insight into how evolutionary processes shape consistent behavioural traits (i.e. personality). Deliberate introductions of non-native species offer opportunities to investigate how such genes differ between native and introduced populations and how polymorphisms in the genes are related to variation in behaviour. Here, we compared the genetic variation of the two 'personality' genes, DRD4 and SERT, between a native (United Kingdom, UK) and an introduced (New Zealand, NZ) population of dunnocks, Prunella modularis. The NZ population showed a significantly lower number of single nucleotide polymorphisms (SNPs) compared to the UK population. Standardized F'st estimates of the personality genes and neutral microsatellites indicate that selection (anthropogenic and natural) probably occurred during and post the introduction event. Notably, the largest genetic differentiation was found in the intronic regions of the genes. In the NZ population, we also examined the association between polymorphisms in DRD4 and SERT and two highly repeatable behavioural traits: flight-initiation distance and mating status (promiscuous females and cobreeding males). We found 38 significant associations (for different allele effect models) between the two behavioural traits and the studied genes. Further, 22 of the tested associations showed antagonistic allele effects for males and females. Our findings illustrate how introduction events and accompanying ecological changes could influence the genetic diversity of behaviour-related genes. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Mortuza, Md Firoz; Lepore, Luigi; Khedkar, Kalpana; Thangam, Saravanan; Nahar, Arifatun; Jamil, Hossen Mohammad; Bandi, Laxminarayan; Alam, Md Khorshed
2018-03-01
Characterization of a 90 kCi (3330 TBq), semi-industrial, cobalt-60 gamma irradiator was performed by commissioning dosimetry and in-situ dose mapping experiments with Ceric-cerous and Fricke dosimetry systems. Commissioning dosimetry was carried out to determine dose distribution pattern of absorbed dose in the irradiation cell and products. To determine maximum and minimum absorbed dose, overdose ratio and dwell time of the tote boxes, homogeneous dummy product (rice husk) with a bulk density of 0.13 g/cm3 were used in the box positions of irradiation chamber. The regions of minimum absorbed dose of the tote boxes were observed in the lower zones of middle plane and maximum absorbed doses were found in the middle position of front plane. Moreover, as a part of dose mapping, dose rates in the wall positions and some selective strategic positions were also measured to carry out multiple irradiation program simultaneously, especially for low dose research irradiation program. In most of the cases, Monte Carlo simulation data, using Monte Carlo N-Particle eXtended code version MCNPX 2.7., were found to be in congruence with experimental values obtained from Ceric-cerous and Fricke dosimetry; however, in close proximity positions from the source, the dose rate variation between chemical dosimetry and MCNP was higher than distant positions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, M.T.; Butler, H.M.; Gupton, E.D.
The UCC-ND Employee Identification Badge contains an indium foil disc that is intended for use as a dosimetry screening device in the event of a criticality accident. While it is recognized that indium is not a precise mixed neutron-gamma dosimeter, its activation by neutrons provides adequate means for separating potentially exposed persons into three groups. These groups are: (1) personnel exposed below annual dose limits, (2) personnel exposed above annual dose limits but below 25 rem, and (3) personnel exposed above 25 rem. This screening procedure is designed to facilitate dosimeter processing in order to meet regulatory reporting requirements. Amore » quick method of interpreting induced activity measurements is presented and discussed.« less
Adam, Rachel
2007-08-31
Recent policy and organisational changes within UK primary care have emphasised graduated access to care, speed of access to the first available general practitioner (GP) and care being provided by a range of healthcare professionals. These trends have been strengthened by the current GP contract and Quality and Outcomes Framework (QOF). Concern has been expressed that the potential for personal care is being diminished as a result and that this will reduce quality standards. This paper presents data from a study that explored with patients and GPs what personal care means and whether it has continuing importance to them. A semi-structured questionnaire was used to interview participants and Framework Analysis supported analysis of emerging themes. Twenty-nine patients, mainly women with young children, and twenty-three GPs were interviewed from seven practices in Lothian, Scotland, ranged by practice size and relative deprivation score. Personal care was defined mainly, though not exclusively, as care given within the context of a continuing relationship in which there is an interpersonal connection and the doctor adopts a particular consultation style. Defined in this way, it was reported to have benefits for both health outcomes and patients' experience of care. In particular, such care was thought to be beneficial in attending to the emotions that can be elicited when seeking and receiving health care and in enabling patients to be known by doctors as legitimate seekers of care from the health service. Its importance was described as being dependent upon the nature of the health problem and patients' wider familial and social circumstances. In particular, it was found to provide support to patients in their parenting and other familial caring roles. Personal care has continuing salience to patients and GPs in modern primary care in the UK. Patients equate the experience of care, not just outcomes, with high quality care. As it is mainly conceptualised and experienced as care within the context of a continuing relationship, policies and organisational arrangements that support and give incentives to this must be in place. These preferences are not strongly reflected in the QOF. Specific questions need to be addressed by future audit and research on the impact of the contract on these aspects of service.
Effectiveness of herpes zoster vaccination in an older United Kingdom population.
Walker, Jemma L; Andrews, Nick J; Amirthalingam, Gayatri; Forbes, Harriet; Langan, Sinead M; Thomas, Sara L
2018-04-19
Vaccination against herpes zoster was introduced in the United Kingdom in 2013 for individuals aged 70 years, with a phased catch-up campaign for 71-79 year olds. Vaccine introduction has resulted in a marked fall in incident herpes zoster and in post-herpetic neuralgia (PHN), but formal evaluation of vaccine effectiveness is needed. In a population-based cohort study of older individuals born between 1933 and 1946, we used linked UK anonymised primary care health records for the first three years of the vaccination programme (01/09/2013-31/08/2016) and multivariable Poisson regression to obtain incidence rates and vaccine effectiveness (VE) against zoster and PHN. Among 516,547 individuals, 21% were vaccinated. Incidence of zoster was 3.15/1000 person-years in vaccinees and 8.80/1000 person-years in unvaccinated individuals. After adjustment, VE was 64% (95%CI = 60-68%) against incident zoster and 81% (95%CI = 61-91%) against PHN, with very similar VE estimates in the routine and catch-up cohorts. VE against zoster was lower in those with a previous history of zoster: 47% (95%CI = 31-58%) versus 64% (95%CI = 60-68%) in those without previous zoster. There was evidence of waning VE over time, from 69% (95%CI = 65-74%) in the first year after vaccination to 45% (95%CI = 29-57%) by the third year. This first formal assessment of VE in the UK zoster vaccination programme demonstrates good effectiveness of zoster vaccine, and very good protection against PHN. The findings provide evidence that VE is similar across the age groups targeted for vaccination in the UK, and on duration of protection of the vaccine in public health use. The study provides key information for decision-makers about the future direction of UK zoster vaccination programme, indicating that the live zoster vaccine may be more cost-effective than estimated previously. It also supports efforts to communicate the benefits of zoster vaccination to address the declining coverage observed across the UK. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
AbdelMalik, Philip; Boulos, Maged N Kamel; Jones, Ray
2008-01-01
Background The "place-consciousness" of public health professionals is on the rise as spatial analyses and Geographic Information Systems (GIS) are rapidly becoming key components of their toolbox. However, "place" is most useful at its most precise, granular scale – which increases identification risks, thereby clashing with privacy issues. This paper describes the views and requirements of public health professionals in Canada and the UK on privacy issues and spatial data, as collected through a web-based survey. Methods Perceptions on the impact of privacy were collected through a web-based survey administered between November 2006 and January 2007. The survey targeted government, non-government and academic GIS labs and research groups involved in public health, as well as public health units (Canada), ministries, and observatories (UK). Potential participants were invited to participate through personally addressed, standardised emails. Results Of 112 invitees in Canada and 75 in the UK, 66 and 28 participated in the survey, respectively. The completion proportion for Canada was 91%, and 86% for the UK. No response differences were observed between the two countries. Ninety three percent of participants indicated a requirement for personally identifiable data (PID) in their public health activities, including geographic information. Privacy was identified as an obstacle to public health practice by 71% of respondents. The overall self-rated median score for knowledge of privacy legislation and policies was 7 out of 10. Those who rated their knowledge of privacy as high (at the median or above) also rated it significantly more severe as an obstacle to research (P < 0.001). The most critical cause cited by participants in both countries was bureaucracy. Conclusion The clash between PID requirements – including granular geography – and limitations imposed by privacy and its associated bureaucracy require immediate attention and solutions, particularly given the increasing utilisation of GIS in public health. Solutions include harmonization of privacy legislation with public health requirements, bureaucratic simplification, increased multidisciplinary discourse, education, and development of toolsets, algorithms and guidelines for using and reporting on disaggregate data. PMID:18471295
AbdelMalik, Philip; Boulos, Maged N Kamel; Jones, Ray
2008-05-09
The "place-consciousness" of public health professionals is on the rise as spatial analyses and Geographic Information Systems (GIS) are rapidly becoming key components of their toolbox. However, "place" is most useful at its most precise, granular scale - which increases identification risks, thereby clashing with privacy issues. This paper describes the views and requirements of public health professionals in Canada and the UK on privacy issues and spatial data, as collected through a web-based survey. Perceptions on the impact of privacy were collected through a web-based survey administered between November 2006 and January 2007. The survey targeted government, non-government and academic GIS labs and research groups involved in public health, as well as public health units (Canada), ministries, and observatories (UK). Potential participants were invited to participate through personally addressed, standardised emails. Of 112 invitees in Canada and 75 in the UK, 66 and 28 participated in the survey, respectively. The completion proportion for Canada was 91%, and 86% for the UK. No response differences were observed between the two countries. Ninety three percent of participants indicated a requirement for personally identifiable data (PID) in their public health activities, including geographic information. Privacy was identified as an obstacle to public health practice by 71% of respondents. The overall self-rated median score for knowledge of privacy legislation and policies was 7 out of 10. Those who rated their knowledge of privacy as high (at the median or above) also rated it significantly more severe as an obstacle to research (P < 0.001). The most critical cause cited by participants in both countries was bureaucracy. The clash between PID requirements - including granular geography - and limitations imposed by privacy and its associated bureaucracy require immediate attention and solutions, particularly given the increasing utilisation of GIS in public health. Solutions include harmonization of privacy legislation with public health requirements, bureaucratic simplification, increased multidisciplinary discourse, education, and development of toolsets, algorithms and guidelines for using and reporting on disaggregate data.
TREE Preferred Procedures, Selected Electronic Parts.
1982-01-31
presented. Chapter 5 covers dosimetry and environmental correlation procedures. Neutron measurements, photon and electron measurements, and pulse...complications from nonuniformity of dose and to provide accurate dosimetry , exposures should be performed under conditions of electron equi- librium. Unless...nonconducting dosimetry materials or test articles are exposed to intense electron beams characteristic of flash X-ray machines, the effect of the potential
Verification of an on line in vivo semiconductor dosimetry system for TBI with two TLD procedures.
Sánchez-Doblado, F; Terrón, J A; Sánchez-Nieto, B; Arráns, R; Errazquin, L; Biggs, D; Lee, C; Núñez, L; Delgado, A; Muñiz, J L
1995-01-01
This work presents the verification of an on line in vivo dosimetry system based on semiconductors. Software and hardware has been designed to convert the diode signal into absorbed dose. Final verification was made in the form of an intercomparison with two independent thermoluminiscent (TLD) dosimetry systems, under TBI conditions.
Develop real-time dosimetry concepts and instrumentation for long term missions
NASA Technical Reports Server (NTRS)
Braby, L. A.
1981-01-01
The development of a rugged portable dosimetry system, based on microdosimetry techniques, which will measure dose and evaluate dose equivalent in a mixed radiation field is described. Progress in the desired dosimetry system can be divided into three distinct areas: development of the radiation detector, and electron system are presented. The mathematical techniques required are investigated.
Methods and Models of the Hanford Internal Dosimetry Program, PNNL-MA-860
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.
2003-01-03
This manual describes the technical basis for the design of the routine radiobioassay monitoring program and assessments of internal dose. Its purpose is to provide a historical record of the methods, models, and assumptions used for internal dosimetry at Hanford, and serve as a technical reference for radiation protection and dosimetry staff.
A continuum of HIV care describing mortality and loss to follow-up: a longitudinal cohort study.
Jose, Sophie; Delpech, Valerie; Howarth, Alison; Burns, Fiona; Hill, Teresa; Porter, Kholoud; Sabin, Caroline A
2018-06-01
The cross-sectional HIV care continuum is widely used to assess the success of HIV care programmes among populations of people with HIV and the potential for ongoing transmission. We aimed to investigate whether a longitudinal continuum, which incorporates loss to follow-up and mortality, might provide further insights about the performance of care programmes. In this longitudinal cohort study, we included individuals who entered the UK Collaborative HIV Cohort (CHIC) study between Jan 1, 2000, and Dec 31, 2004, and were linked to the national HIV cohort database (HIV and AIDS Reporting System). For each month during a 10 year follow up period, we classified individuals into one of ten distinct categories according to engagement in care, antiretroviral therapy (ART) use, viral suppression, loss to cohort follow-up and loss to care, and mortality, and assessed the proportion of person-months of follow-up spent in each stage of the continuum. 5 year longitudinal continuums were also constructed for three separate cohorts (baseline years of entry 2000-03, 2004-07, and 2008-09) to compare changes over time. We included 12 811 people contributing 1 537 320 person-months in our analysis. During 10 years of follow-up, individuals spent 811 057 (52·8%) of 1 537 320 person-months on ART. Of the 811 057 person-months spent on ART, individuals had a viral load of 200 copies per mL or less for 607 185 (74·9%) person-months. 10 years after cohort entry, 3612 (28·1%) of 12 811 individuals were lost to follow-up, 954 (26·4%) of whom had transferred to a non-CHIC UK clinic for care. By 10 years, 759 (5·9%) of 12 811 participants who entered the cohort had died. Loss to follow-up decreased and the proportion of person-months that individuals spent virally suppressed increased over calendar time. Loss to follow-up in HIV care programmes was high and rates of viral suppression were lower than previously reported. Complementary information provided by a longitudinal continuum might highlight areas for intervention along the HIV care pathway, however, transfers outside the cohort must be accounted for. Medical Research Council, UK. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Calibration of a mosfet detection system for 6-MV in vivo dosimetry.
Scalchi, P; Francescon, P
1998-03-01
Metal oxide semiconductor field-effect transistor (MOSFET) detectors were calibrated to perform in vivo dosimetry during 6-MV treatments, both in normal setup and total body irradiation (TBI) conditions. MOSFET water-equivalent depth, dependence of the calibration factors (CFs) on the field sizes, MOSFET orientation, bias supply, accumulated dose, incidence angle, temperature, and spoiler-skin distance in TBI setup were investigated. MOSFET reproducibility was verified. The correlation between the water-equivalent midplane depth and the ratio of the exit MOSFET readout divided by the entrance MOSFET readout was studied. MOSFET midplane dosimetry in TBI setup was compared with thermoluminescent dosimetry in an anthropomorphic phantom. By using ionization chamber measurements, the TBI midplane dosimetry was also verified in the presence of cork as a lung substitute. The water-equivalent depth of the MOSFET is about 0.8 mm or 1.8 mm, depending on which sensor side faces the beam. The field size also affects this quantity; Monte Carlo simulations allow driving this behavior by changes in the contaminating electron mean energy. The CFs vary linearly as a function of the square field side, for fields ranging from 5 x 5 to 30 x 30 cm2. In TBI setup, varying the spoiler-skin distance between 5 mm and 10 cm affects the CFs within 5%. The MOSFET reproducibility is about 3% (2 SD) for the doses normally delivered to the patients. The effect of the accumulated dose on the sensor response is negligible. For beam incidence ranging from 0 degrees to 90 degrees, the MOSFET response varies within 7%. No monotonic correlation between the sensor response and the temperature is apparent. Good correlation between the water-equivalent midplane depth and the ratio of the exit MOSFET readout divided by the entrance MOSFET readout was found (the correlation coefficient is about 1). The MOSFET midplane dosimetry relevant to the anthropomorphic phantom irradiation is in agreement with TLD dosimetry within 5%. Ionization chamber and MOSFET midplane dosimetry in inhomogeneous phantoms are in agreement within 2%. MOSFET characteristics are suitable for the in vivo dosimetry relevant to 6-MV treatments, both in normal and TBI setup. The TBI midplane dosimetry using MOSFETs is valid also in the presence of the lung, which is the most critical organ, and allows verifying that calculation of the lung attenuator thicknesses based only on the density is not correct. Our MOSFET dosimetry system can be used also to determine the surface dose by using the water-equivalent depth and extrapolation methods. This procedure depends on the field size used.
On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy.
Chen, Z; Agostinelli, A; Nath, R
1998-03-01
The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120 cm x 200 cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated than an additional error of up to 4% could be introduced if the unshielded cable's spatial configuration were altered during the two-polarity measurements. This suggests that automatic scanning systems with unshielded cables should not be used in TSET ionization chamber dosimetry. However, the data did show that an unshielded cable may be used in TSET ionization chamber dosimetry if the size of cable-induced error in a given TSET beam is pre-evaluated and the measurement is carefully conducted. When such an evaluation has not been performed, additional shielding should be applied to the cable being used, making measurements at multiple points difficult.
Jack, B A; Kirton, J A; Downing, J; Frame, K
2015-12-14
There is a global need to expand palliative care services to reach the increasing number requiring end of life care. In developing countries where the incidences of cancer are rising there is an urgent need to develop the palliative care workforce. This paper reports on a UK Department for international development (DFID) initiative funded through the Tropical Health Education Trust (THET) where palliative care staff, both clinical and academic, volunteered to help to develop, support and deliver a degree in palliative care in sub-Saharan Africa. The objective of the study was to explore the personal impact on the health care professionals of being part of this initiative. An evaluation approach using a confidential electronic survey containing quantitative and qualitative questions was distributed to all 17 volunteers on the programme, three months after completion of the first cohort. Data were analysed using descriptive statistics and content thematic analysis. Ethical review deemed the study to be service evaluation. 82 % (14) responded and several themes emerged from the data including the positive impact on teaching and educational skills; clinical practice and finally personal development. Using a score of 1-10 (1-no impact, 10 maximum impact) 'Lifestyle choices - life work balance' (rating 7.83) had the most impact. This approach to supporting the development of palliative care in Sub-Saharan Africa through skill sharing in supporting the delivery of a degree programme in palliative care was successful in terms of delivery of the degree programme, material development and mentorship of local staff. Additionally, this study shows it provided a range of positive impacts on the volunteer health care professionals from the UK. Professional impacts including increased management skills, and being better prepared to undertake a senior role. However it is the personal impact including lifestyle choices which the volunteers reported as the highest impact. Interestingly, several of the faculty have joined other volunteer programmes to continue to support the international development of palliative care.
Pitman, Alexandra; Nesse, Hedvig; Morant, Nicola; Azorina, Valeriya; Stevenson, Fiona; King, Michael; Osborn, David
2017-12-13
People bereaved by suicide are at increased risk of suicide attempt and suicide, but explanations for these associations remain theoretical. It is possible that the experience of suicide bereavement modifies personal attitudes towards suicide, but the nature of these changes remains unexplored. There is a need to understand personal attitudes to suicide following suicide bereavement, as this may inform the development of suicide prevention interventions. Our aim was to explore the attitudes of young adults bereaved by suicide towards their own likelihood of dying by suicide. We conducted a cross-sectional study of staff and students aged 18-40 at 37 United Kingdom (UK) higher educational institutions in 2010. Ethical approval was granted by the UCL Research Ethics Committee. Qualitative responses to a question probing attitudes to own suicide were provided by 429 respondents who had experienced bereavement by the suicide of a close contact. We identified key themes in this dataset using thematic analysis. Analysis identified four main themes: suicide as a more tangible option (whether feared or not); identification with the deceased and awareness of shared vulnerabilities to suicide; personal determination to avoid suicide; and beliefs regarding safeguards against suicide. These themes reflected a broad split in participants' views regarding own likelihood of dying by suicide, influenced by the degree to which own suicide was feared and the extent to which they felt in control of determining a suicide death. Whilst the majority described an aversion to the idea of attempting suicide themselves, largely through an awareness of the impact on others, a minority described their experiences as having normalised suicide as a personal option. The views of a sample of UK-based adults bereaved by suicide suggest that exposure to the suicide of a close friend or relative can influence attitudes to suicide in ways that could influence own risk of suicide attempt. The normalising attitudes to suicide observed in a minority of respondents could contribute to the observed association between suicide bereavement and suicide attempt.
Karasneh, Jumana; Al-Omiri, Mahmoud K; Al-Hamad, Khaled Q; Al Quran, Firas A M
2009-11-01
The aim of this study was to investigate the relationship between patients' oral health-related quality of life, satisfaction with their dentition, and their personality profiles. Eighty-four patients (30 males and 54 females; mean age 31.9+/-12.7 years) seeking routine dental treatment were recruited for this study. A "Dental Impact on Daily Living" (DIDL) questionnaire was used to assess dental satisfaction and impact on daily living. An "Oral Health Impact Profile" (OHIP) was used to measure self-reported discomfort, disability, and dysfunction caused by oral conditions. Oral health-related quality of life was assessed using the "United Kingdom Oral Health Related Quality of Life" measure (OHQoL-U.K). A "NEO Five Factor inventory" (NEO-FFI) was used to assess personality profiles. The dentition has a measurable impact on daily living as well as with satisfaction with appearance, pain levels, oral comfort, general performance, and eating capability (p=0.000). Younger patients had more profound oral health impacts (p=0.045) and higher neuroticism scores (0.043). OHIP scores were significantly related to OHQoL-UK scores (p=0.000). DIDL scores had significant correlations with OHIP and OHQoL-UK scores (p<0.05). Significant correlations were established between neuroticism and satisfaction with oral comfort, extraversion and total satisfaction and satisfaction with general performance, and openness and satisfaction with appearance (p<0.05). OHIP and OHQoL-UK scores had no significant correlations with psychological profiles. The status of the oral cavity can have a definitive impact on patients' daily living and quality of life regardless age, gender, and level of education. Patients' satisfaction with their dentition has definitive impacts on daily living, quality of life, and dental perceptions. Personality profiles (neuroticism; extraversion, and openness) may influence dental perceptions, play a significant role in shaping satisfaction with dentition, and help with the prediction of the dental impact on daily living. Since patients' satisfaction with their dentitions impacts their daily living and quality of life while affected by their psychological profiles, this should be considered when formulating a treatment plan for management for their dentition in order to obtain patient acceptance of the proposed treatment.
Student career choice in psychiatry: findings from 18 UK medical schools.
Halder, Neel; Hadjidemetriou, Christiana; Pearson, Rachel; Farooq, Kitty; Lydall, Gregory J; Malik, Amit; Bhugra, Dinesh
2013-08-01
Psychiatry recruitment continues to be a problem in the UK and large-scale studies are required to understand the factors surrounding this. A quantitative, cross-sectional online survey, incorporating demographics, career choices, teaching exposure, attitudes to psychiatry and personality factors, was administered to final-year UK medical students. A total of 484 students from 18 medical schools responded (66% women). Sixteen (16%) had chosen psychiatry at medical school entry. By final year, 15 respondents (3%) had decided to pursue a career in psychiatry, while another 78 (17%) were seriously considering it. There was little difference in the quality ratings of lectures and small group teaching between those interested in psychiatry and those not. Experience of 'enrichment activities' (psychiatry special study modules or components, psychiatric research, university psychiatry clubs, and psychiatry electives) were significantly more likely to take up psychiatry. Causality cannot, however, be determined in this study. The study identified several distinct groups of UK students: those deciding on psychiatry before medical school and maintaining that career choice, those deciding on psychiatry during medical school, and those interested in other fields. Addressing psychiatry teaching and exposure may improve recruitment into the speciality.
Sweeting, Helen; Walker, Laura; MacLean, Alice; Patterson, Chris; Räisänen, Ulla; Hunt, Kate
Media presentations of health issues affect evaluations of personal susceptibility to particular illnesses and hence help-seeking behaviours. We examined data on prevalence of eating disorders (EDs - which are often characterised as 'female') among males in: scientific literature; readily-accessible web-based information; and UK newspaper articles (published 7/12/2002-7/12/2012). This revealed conflicting statistics. Academic papers suggest men comprise around 25% of community-based samples, but much lower proportions (10% or less) of clinic samples. Websites and newspapers present widely differing statistics both on prevalence overall (numbers with EDs in the UK ranged from 60,000 to 2.7 million), and in men (generally suggesting they constituted 10-25% of those with EDs), rarely distinguishing between diagnosed and non-diagnosed samples. By 2011, newspapers were more consistent on overall numbers with EDs in the UK (1.6 million) and the proportion who were men (20%), drawing on one website as the authoritative source. Conflicting statistics may confuse men searching for ED (or other) health-related information, lead to underestimations of male susceptibility to EDs and/or reinforce inappropriate stereotypes of EDs as confined to adolescent girls.
Diabetes UK Position Statement. Competency frameworks in diabetes.
Simmons, D; Deakin, T; Walsh, N; Turner, B; Lawrence, S; Priest, L; George, S; Vanterpool, G; McArdle, J; Rylance, A; Terry, G; Little, P
2015-05-01
The quality, skills and attitudes of staff working in the healthcare system are central to multidisciplinary learning and working, and to the delivery of the quality of care patients expect. Patients want to know that the staff supporting them have the right knowledge and attitudes to work in partnership, particularly for conditions such as diabetes where 95% of all care is delivered by the person with diabetes themselves. With the current changes in the NHS structures in England, and the potential for greater variation in the types of 'qualified provider', along with the recent scandal at Mid-Staffordshire Hospital, staff need to be shown to be competent and named/accredited or recognized as such. This will help to restore faith in an increasingly devolved delivery structure. The education and validation of competency needs to be consistently delivered and assured to ensure standards are maintained for different roles and disciplines across each UK nation. Diabetes UK recommends that all NHS organizations prioritize healthcare professional education, training and competency through the implementation of a National Diabetes Competency Framework and the phased approach to delivery to address this need. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.
Schmidt, K; Jacobs, P A; Barton, A
2002-09-01
To investigate whether there is a difference in general practitioners' attitudes towards CAM in the UK and Germany. A descriptive questionnaire was developed and sent to 97 GPs in the UK and 99 GPs in Germany. The overall response rate was 68%. German GPs showed a (non-significant) overall more positive attitude towards CAM than did British GPs. British GPs made more referrals to complementary practitioners. The most popular CAM therapies that UK GPs referred their patients to were chiropractic treatment, acupuncture and osteopathy. German GPs referred their patients mainly to acupuncture treatment, chiropractic treatment and herbal medicine. A significantly higher number of German GPs reported having practised as a CAM practitioner before and having personally used CAM themselves. Seventy percent of British GPs and 76% of German GPs thought it is safe to prescribe complementary medicine and therapies to patients. There are small national differences in referring patients to various CAM modalities. Both nations have an overall positive attitude toward and a high interest in CAM. Lack of scientific evidence and information on training opportunities were important points that were continuously raised by GPs in both countries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goke, Sarah Hayes; Elliott, Nathan Ryan
The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program.more » The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.« less
ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.
Afsharpour, H; Landry, G; D'Amours, M; Enger, S; Reniers, B; Poon, E; Carrier, J-F; Verhaegen, F; Beaulieu, L
2012-06-07
Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry platforms. The scientific community has expressed the need for an accurate dosimetry platform in brachytherapy. The purpose of this paper is to present ALGEBRA, a Monte Carlo platform for dosimetry in brachytherapy which is sufficiently fast and accurate for clinical and research purposes. ALGEBRA is based on the GEANT4 Monte Carlo code and is capable of handling the DICOM RT standard to recreate a virtual model of the treated site. Here, the performance of ALGEBRA is presented for the special case of LDR brachytherapy in permanent prostate and breast seed implants. However, the algorithm is also capable of handling other treatments such as HDR brachytherapy.
Merks, Piotr; Kaźmierczak, Justyna; Olszewska, Aleksandra Elzbieta; Kołtowska-Häggström, Maria
2014-01-01
Background Several factors, which are components of pharmaceutical care, can influence a patient’s choice of a community pharmacy store and contribute to frequent visits to the same pharmacy. Objectives To compare factors that influence a patient’s choice of pharmacy in Poland and in the UK, to identify which of them are components of pharmaceutical care, and to relate them to patient loyalty to the same pharmacy. Methods A self-administered, anonymous questionnaire was distributed to clients visiting pharmacies in Poland and the UK January–August 2011. Comparisons were performed using chi-square tests and logistic regression. All statistical analyses were performed using SPSS 20.0. Results The response rate was 55.6% (n=417/750; 36 pharmacies) and 54.0% (n=405/750; 56 pharmacies) in Poland and in the UK, respectively. The most frequently reported factors, as defined by a percentage of responders, were in Poland: 1) location (84%); 2) professional and high-quality of service (82%); 3) good price of medicines (78%); and 4) promotions on medicines (66%). In the UK, the most commonly reported factors were: 1) professional and high quality of service (90%); 2) location (89%); 3) good advice received from the pharmacist (86%); and 4) option of discussing and consulting all health issues in a consultation room (80%). Good advice and an option of discussing personal concerns with a pharmacist are components of pharmaceutical care. Thirty-eight percent of patients in Poland and 61% in the UK declared visiting the same pharmacy. Conclusion Components of pharmaceutical care are important factors influencing the patient’s choice of pharmacy in the UK and, to a lesser degree, in Poland. Additionally, more patients in the UK than in Poland are committed to a single pharmacy. Therefore, implementing the full pharmaceutical care in Poland may contribute to an increase in patient loyalty and thus strengthen competitiveness of pharmacy businesses. PMID:24868150
Patterson, S; Jose, S; Samji, H; Cescon, A; Ding, E; Zhu, J; Anderson, J; Burchell, A N; Cooper, C; Hill, T; Hull, M; Klein, M B; Loutfy, M; Martin, F; Machouf, N; Montaner, Jsg; Nelson, M; Raboud, J; Rourke, S B; Tsoukas, C; Hogg, R S; Sabin, C
2017-10-01
We sought to compare all-cause mortality of people living with HIV and accessing care in Canada and the UK. Individuals from the Canadian Observational Cohort (CANOC) collaboration and UK Collaborative HIV Cohort (UK CHIC) study who were aged ≥ 18 years, had initiated antiretroviral therapy (ART) for the first time between 2000 and 2012 and who had acquired HIV through sexual transmission were included in the analysis. Cox regression was used to investigate the difference in mortality risk between the two cohort collaborations, accounting for loss to follow-up as a competing risk. A total of 19 960 participants were included in the analysis (CANOC, 4137; UK CHIC, 15 823). CANOC participants were more likely to be older [median age 39 years (interquartile range (IQR): 33, 46 years) vs. 36 years (IQR: 31, 43 years) for UK CHIC participants], to be male (86 vs. 73%, respectively), and to report men who have sex with men (MSM) sexual transmission risk (72 vs. 56%, respectively) (all P < 0.001). Overall, 762 deaths occurred during 98 798 person-years (PY) of follow-up, giving a crude mortality rate of 7.7 per 1000 PY [95% confidence interval (CI): 7.1, 8.3 per 1000 PY]. The crude mortality rates were 8.6 (95% CI: 7.4, 10.0) and 7.5 (95% CI: 6.9, 8.1) per 1000 PY among CANOC and UK CHIC study participants, respectively. No statistically significant difference in mortality risk was observed between the cohort collaborations in Cox regression accounting for loss to follow-up as a competing risk (adjusted hazard ratio 0.86; 95% CI: 0.72-1.03). Despite differences in national HIV care provision and treatment guidelines, mortality risk did not differ between CANOC and UK CHIC study participants who acquired HIV through sexual transmission. © 2017 The Authors. HIV Medicine published by John Wiley & Sons Ltd on behalf of British HIV Association.
Mori, Hiroshige
2015-06-01
The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.
Rojas-Anaya, Hector; Skogen, Karoline; Miles, Kenneth Alan
2012-06-01
To identify factors that influence the use of PET in phase III oncology trials in the UK by evaluating stakeholder perspectives. A wide range of UK PET research stakeholders with a potential interest in the use of PET in phase III trials were identified and invited to participate. These UK PET research stakeholders were consulted using a semistructured questionnaire on their personal experience with and involvement in PET research, the role of PET in phase III oncology clinical trials and on the promotion of UK PET research and unmet clinical needs in oncology. Responses were analysed quantitatively and by qualitative content analysis of free-text responses. A total of 118 responses were received from a wide range of stakeholders representing several professional groups and working environments. Of these respondents, 49 (42%) were using PET in their research. There was the general perception that using PET in clinical research is beneficial in oncology. The two major barriers identified were poor availability of PET and perceived difficulties in funding of excess treatment costs (75% of respondents). Other factors included limited coverage of PET in training, uncertainty about developing imaging protocols or the status of tracers other than 18F-fluorodeoxyglucose, and low awareness of the role of PET in patient selection for therapeutic trials. Patient concerns about radiation were not perceived as a research barrier. Interventions that improve the availability and funding pathways for PET research scans and that increase researcher awareness could help promote the use of PET for phase III oncology trials in the UK.
Jackson, Diana; Seaman, Karla; Sharp, Kristylee; Singer, Rachel; Wagland, Janet; Turner-Stokes, Lynne
2017-01-01
To compare the UK Functional Assessment Measure (UK FIM+FAM) and Mayo-Portland Adaptability Inventory (MPAI-4) as measures of functional change in patients with brain injury receiving a staged residential post-acute community-based rehabilitation programme. Longitudinal cohort study of consecutive admissions (N = 42) over 3 years. Patients were assessed at admission and discharge/annual review. We examined groups according to stage of independence on admission: Maximum support (stages 1 and 2: N = 17); moderate/maximum self-care/household support (stage 3: N = 15); minimal self-care and moderate household/community support (stages 4-6: N = 10). Median (IQR) age: 50 (37-56) years. Male:female ratio: (71%:29%). Aetiology: stroke (50%), traumatic (36%) and other brain injuries (14%). Both tools demonstrated significant gains in overall scores and all subscales (p < 0.01). However, the UK FIM+FAM provides more detailed evaluation of personal activities of daily living and mobility, which were most relevant in clients admitted in graduation stages 1 and 2 of the programme, whereas the MPAI-4 was more sensitive to changes in adjustment and participation for clients admitted in the later stages (4-6). The UK FIM+FAM and MPAI-4 provide complementary evaluation across functional tasks ranging from self-care to participation. This study supports their use for longitudinal outcome evaluation in community residential rehabilitation services that take patients at different stages of recovery.
FX-25 and FX-100 Propagation Experiments.
1982-07-01
Radiochromic Foil Dosimetry Blue cellophane is one of the most widely used radiochromic film dosimeters.6 Blue cellophane exposed to an intense electron ...shown in Fig. 18, Appendix B. Thermoluminescent Dosimetry Lithium flouride thermoluminescent dosimeters ( TLDs ) were on a limited number of shots to...corroboration of the current distribution included radiochromic-film dosimetry , TLD arrays, and openshutter photography. Because of our discovery of the
TRIAGE of Irradiated Personnel
1996-09-25
Vivo Electron Paramagnetic Resonance, Electron Spin Resonance (EPR, ESR) for In Vivo Dosimetry Under Field Conditions Dr. Harold M. Swartz Dartmouth...Force Medical Center Andrews Air Force Base, MD • Status and Limitations of Physical Dosimetry in the Field Environment David A. Schauer, LCDR, MSC...USN Naval Dosimetry Center Navy Environmental Health Center Detachment Bethesda, MD • NATO Policy and Guidance on Antiemetic Usage Robert Kehlet
Hanford internal dosimetry program manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.
1989-10-01
This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs.
USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature: Second Report.
1982-05-01
10 Cellular 11 Mechanisms of interaction 12 Environmental 13 Medical applications 14 Review 15 Ecological 16 Physical methods/dosimetry 17 Other 18...APPLICATIONS List of Analyses ......... .................... 137 (14) REVIEW List of Analyses ......... .................... 138 (16) PHYSICAL METHODS/DOSIMETRY...physiological 10 Cellular 11 Mechanisms of interaction 12 Environmental 13 Medical applications 14 Review 15 Ecological 16 Physical methods/dosimetry 17
To maximize the value of toxicological data in development of human health risk assessment models of inhaled elongated mineral particles, improvements in human dosimetry modeling are needed. In order to extend the dosimetry model of deposited fibers (Asgharian et aI., Johnson 201...
In vivo thermoluminescence dosimetry for total body irradiation.
Palkosková, P; Hlavata, H; Dvorák, P; Novotný, J; Novotný, J
2002-01-01
An improvement in the clinical results obtained using total body irradiation (TBI) with photon beams requires precise TBI treatment planning, reproducible irradiation, precise in vivo dosimetry, accurate documentation and careful evaluation. In vivo dosimetry using LiF Harshaw TLD-100 chips was used during the TBI treatments performed in our department. The results of in vivo thermoluminescence dosimetry (TLD) show that using TLD measurements and interactive adjustment of some treatment parameters based on these measurements, like monitor unit calculations, lung shielding thickness and patient positioning, it is possible to achieve high precision in absorbed dose delivery (less than 0.5%) as well as in homogeneity of irradiation (less than 6%).
3D dosimetry by optical-CT scanning
NASA Astrophysics Data System (ADS)
Oldham, Mark
2006-12-01
The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (within 7% dose-difference or 4mm distance-to-agreement) evaluated at a half-dozen points and a single axial plane. The question that arises from this disturbing finding is - what percentage of institutions would have failed if a comprehensive 3D measurement had been feasible, rather than measurements restricted to the central film-plane and TLD points? This question can only be adequately answered by a comprehensive 3D-dosimetry system, which presents a compelling argument for its development as a clinically viable low cost dosimetry solution. Optical-CT dosimetry is perhaps the closest system to providing such a comprehensive solution. In this article, we review the origins and recent developments of optical-CT dosimetry systems. The principle focus is on first generation systems known to have highest accuracy but longer scan times.
Nuclear accident dosimetry intercomparison studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sims, C.S.
1989-09-01
Twenty-two nuclear accident dosimetry intercomparison studies utilizing the fast-pulse Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a total of 62 different organizations a forum for discussion of criticality accident dosimetry, an opportunity to test their neutron and gamma-ray dosimetry systems under a variety of simulated criticality accident conditions, and the experience of comparing results with reference dose values as well as with the measured results obtained by others making measurements under identical conditions. Sixty-nine nuclear accidents (27 with unmoderated neutron energy spectra and 42 with eight different shieldedmore » spectra) have been simulated in the studies. Neutron doses were in the 0.2-8.5 Gy range and gamma doses in the 0.1-2.0 Gy range. A total of 2,289 dose measurements (1,311 neutron, 978 gamma) were made during the intercomparisons. The primary methods of neutron dosimetry were activation foils, thermoluminescent dosimeters, and blood sodium activation. The main methods of gamma dose measurement were thermoluminescent dosimeters, radiophotoluminescent glass, and film. About 68% of the neutron measurements met the accuracy guidelines (+/- 25%) and about 52% of the gamma measurements met the accuracy criterion (+/- 20%) for accident dosimetry.« less
Hänscheid, Heribert; Canzi, Cristina; Eschner, Wolfgang; Flux, Glenn; Luster, Markus; Strigari, Lidia; Lassmann, Michael
2013-07-01
The EANM Dosimetry Committee Series "Standard Operational Procedures for Pre-Therapeutic Dosimetry" (SOP) provides advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This particular SOP describes how to tailor the therapeutic activity to be administered for radioiodine therapy of benign thyroid diseases such as Graves' disease or hyperthyroidism. Pretherapeutic dosimetry is based on the assessment of the individual (131)I kinetics in the target tissue after the administration of a tracer activity. The present SOP makes proposals on the equipment to be used and guides the user through the measurements. Time schedules for the measurement of the fractional (131)I uptake in the diseased tissue are recommended and it is shown how to calculate from these datasets the therapeutic activity necessary to administer a predefined target dose in the subsequent therapy. Potential sources of error are pointed out and the inherent uncertainties of the procedures depending on the number of measurements are discussed. The theoretical background and the derivation of the listed equations from compartment models of the iodine kinetics are explained in a supplementary file published online only.
Trompier, François; Burbidge, Christopher; Bassinet, Céline; Baumann, Marion; Bortolin, Emanuela; De Angelis, Cinzia; Eakins, Jonathan; Della Monaca, Sara; Fattibene, Paola; Quattrini, Maria Cristina; Tanner, Rick; Wieser, Albrecht; Woda, Clemens
2017-01-01
In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Resonance (EPR) dosimetry techniques. OSL is applied to electronic components and EPR to touch-screen glass from mobile phones. To implement these new approaches, several blind tests and inter-laboratory comparisons (ILC) were organized for each assay. OSL systems have shown good performances. EPR systems also show good performance in controlled conditions, but ILC have also demonstrated that post-irradiation exposure to sunlight increases the complexity of the EPR signal analysis. Physically-based dosimetry techniques present high capacity, new possibilities for accident dosimetry, especially in the case of large-scale events. Some of the techniques applied can be considered as operational (e.g. OSL on Surface Mounting Devices [SMD]) and provide a large increase of measurement capacity for existing networks. Other techniques and devices currently undergoing validation or development in Europe could lead to considerable increases in the capacity of the RENEB accident dosimetry network.
Kuempel, Eileen D.; Sweeney, Lisa M.; Morris, John B.; Jarabek, Annie M.
2015-01-01
The purpose of this article is to provide an overview and practical guide to occupational health professionals concerning the derivation and use of dose estimates in risk assessment for development of occupational exposure limits (OELs) for inhaled substances. Dosimetry is the study and practice of measuring or estimating the internal dose of a substance in individuals or a population. Dosimetry thus provides an essential link to understanding the relationship between an external exposure and a biological response. Use of dosimetry principles and tools can improve the accuracy of risk assessment, and reduce the uncertainty, by providing reliable estimates of the internal dose at the target tissue. This is accomplished through specific measurement data or predictive models, when available, or the use of basic dosimetry principles for broad classes of materials. Accurate dose estimation is essential not only for dose-response assessment, but also for interspecies extrapolation and for risk characterization at given exposures. Inhalation dosimetry is the focus of this paper since it is a major route of exposure in the workplace. Practical examples of dose estimation and OEL derivation are provided for inhaled gases and particulates. PMID:26551218
Hu, B; Wang, Y; Zealey, W
2009-12-01
A commercial Optical Stimulated Luminescence (OSL) dosimetry system developed by Landauer was tested to analyse the possibility of using OSL dosimetry for external beam radiotherapy planning checks. Experiments were performed to determine signal sensitivity, dose response range, beam type/energy dependency, reproducibility and linearity. Optical annealing processes to test OSL material reusability were also studied. In each case the measurements were converted into absorbed dose. The experimental results show that OSL dosimetry provides a wide dose response range, good linearity and reproducibility for the doses up to 800cGy. The OSL output is linear with dose up to 600cGy range showing a maximum deviation from linearity of 2.0% for the doses above 600cGy. The standard deviation in response of 20 dosimeters was 3.0%. After optical annealing using incandescent light, the readout intensity decreased by approximately 98% in the first 30 minutes. The readout intensity, I, decreased after repeated optical annealing as a power law, given by I infinity t (-1.3). This study concludes that OSL dosimetry can provide an alternative dosimetry technique for use in in-vivo dosimetry if rigorous measurement protocols are established.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mínguez, Pablo, E-mail: pablo.minguezgabina@osakid
Purpose: To investigate the possible differences between SPECT/CT based whole-remnant and maximum-voxel dosimetry in patients receiving radio-iodine ablation treatment of differentiated thyroid cancer (DTC). Methods: Eighteen DTC patients were administered 1.11 GBq of {sup 131}I-NaI after near-total thyroidectomy and rhTSH stimulation. Two patients had two remnants, so in total dosimetry was performed for 20 sites. Three SPECT/CT scans were performed for each patient at 1, 2, and 3–7 days after administration. The activity, the remnant mass, and the maximum-voxel activity were determined from these images and from a recovery-coefficient curve derived from experimental phantom measurements. The cumulated activity was estimatedmore » using trapezoidal-exponential integration. Finally, the absorbed dose was calculated using S-values for unit-density spheres in whole-remnant dosimetry and S-values for voxels in maximum-voxel dosimetry. Results: The mean absorbed dose obtained from whole-remnant dosimetry was 40 Gy (range 2–176 Gy) and from maximum-voxel dosimetry 34 Gy (range 2–145 Gy). For any given patient, the activity concentrations for each of the three time-points were approximately the same for the two methods. The effective half-lives varied (R = 0.865), mainly due to discrepancies in estimation of the longer effective half-lives. On average, absorbed doses obtained from whole-remnant dosimetry were 1.2 ± 0.2 (1 SD) higher than for maximum-voxel dosimetry, mainly due to differences in the S-values. The method-related differences were however small in comparison to the wide range of absorbed doses obtained in patients. Conclusions: Simple and consistent procedures for SPECT/CT based whole-volume and maximum-voxel dosimetry have been described, both based on experimentally determined recovery coefficients. Generally the results from the two approaches are consistent, although there is a small, systematic difference in the absorbed dose due to differences in the S-values, and some variability due to differences in the estimated effective half-lives, especially when the effective half-life is long. Irrespective of the method used, the patient absorbed doses obtained span over two orders of magnitude.« less
Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.
Hourdakis, Constantine J; Boziari, A
2008-04-01
Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002--2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside +/-3% and 31% outside +/-5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and discussed in details. This quality audit proved to be a useful tool for the improvement of quality in radiotherapy. It succeeded to disseminate the IAEA TRS-398 protocol in nearly all radiotherapy centers achieving homogenization and consistency of dosimetry within the country. Also, it detected discrepancies in dosimetry and provided guidance and recommendations to eliminate sources of errors. Finally, it proved that quality assurance programs, periodic quality control tests, maintenance and service play an important role for achieving accuracy and safe operation in radiotherapy.
Gender identity and the management of the transgender patient: a guide for non-specialists.
Joseph, Albert; Cliffe, Charlotte; Hillyard, Miriam; Majeed, Azeem
2017-04-01
In this review, we introduce the topic of transgender medicine, aimed at the non-specialist clinician working in the UK. Appropriate terminology is provided alongside practical advice on how to appropriately care for transgender people. We offer a brief theoretical discussion on transgenderism and consider how it relates to broader understandings of both gender and disease. In respect to epidemiology, while it is difficult to assess the exact size of the transgender population in the UK, population surveys suggest a prevalence of between 0.2 and 0.6% in adults, with rates of referrals to gender identity clinics in the UK increasing yearly. We outline the legal framework that protects the rights of transgender people, showing that is not legal for physicians to deny transgender people access to services based on their personal beliefs. Being transgender is often, although not always, associated with gender dysphoria, a potentially disabling condition in which the discordance between a person's natal sex (that assigned to them at birth) and gender identity results in distress, with high associated rates of self-harm, suicidality and functional impairment. We show that gender reassignment can be a safe and effective treatment for gender dysphoria with counselling, exogenous hormones and surgery being the mainstay of treatment. The role of the general practitioner in the management of transgender patients is discussed and we consider whether hormone therapy should be initiated in primary care in the absence of specialist advice, as is suggested by recent General Medical Council guidance.
Stagich, Brooke H; Moore, Kelsey R; Newton, Joseph R; Dixon, Kenneth L; Jannik, G Timothy
2017-04-01
Most U.S. Department of Energy (DOE) facilities with radiological airborne releases use the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88-PC to demonstrate compliance with regulations in 40CFR61, subpart H [National Emission Standards for Hazardous Air Pollutants: Radiological (NESHAP)]. In 2015, EPA released Version 4 of CAP88-PC, which included significant modifications that improved usability and age-dependent dose coefficients and usage factors for six age groups (infant, 1 y, 5 y, 10 y, 15 y, and adult). However, EPA has not yet provided specific guidance on how to use these age-dependent factors. For demonstrating compliance with DOE public dose regulations, the Savannah River Site (SRS) recently changed from using the maximally exposed individual (MEI) concept (adult male) to the representative person concept (age- and gender-averaged reference person). In this study, dose comparisons are provided between the MEI and a SRS-specific representative person using the age-specific dose coefficients and usage factors in CAP88-PC V.4. Dose comparisons also are provided for each of the six age groups using five radionuclides of interest at SRS (tritium oxide, Cs, Sr, Pu, and I). In general, the total effective dose increases about 11% for the representative person as compared to the current NESHAP MEI because of the inclusion of the more radiosensitive age groups.
The Edinburgh Primary Care Depression Study: personality disorder and outcome.
Patience, D A; McGuire, R J; Scott, A I; Freeman, C P
1995-09-01
Little is known about the impact of personality pathology on the treatment outcome of major depressive illness in primary care in the UK. Patients meeting criteria for DSM-III major depressive disorder were randomly allocated to one of four treatments each lasting 16 weeks, then followed up for 18 months. Assessments were made of depressive symptoms, personality and social functioning. Personality was assessed at maximum improvement or 16 weeks. The prevalence of personality disorder (PD) in the sample of 113 patients was 26%. Patients with a PD were significantly younger and rated more depressed at entry than patients with no personality disorder (NoPD). On completion of treatment patients with a PD were significantly more depressed and had poorer social functioning than the NoPD group. After 18 months there were no differences in ratings of depression or social functioning between the groups. There was substantial improvement in both the PD and NoPD groups. The presence of personality pathology delays recovery from major depressive illness.
2015-12-01
has always been important to modern governments, but the issue has become much more pressing in the Internet age, when a person’s digital identity...nationals in the UK are being given different cards. 4. Place of birth 5. Signature - digitally embedded in the card 6. Date of card issue and date...license or personal identification card number A digital photograph of the person The person’s address of principal residence The person’s
Alcohol, duty-of-care and common law--where do the consequences of drunken behaviour lie?
Brett, Francesca; Tormey, William
2014-09-01
Legal issues around the duty of care in common law with regard to addictive legal drugs are evolving. Two recent cases came before the Irish courts dealing with the issue of duty of care of alcohol suppliers to intoxicated individuals. In both cases the intoxication was self-induced and the consequences were lethal. The juxtaposition of personal autonomy and duty of care cannot ignore personal responsibility. Do we need protection from ourselves? © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
CGAT: a model for immersive personalized training in computational genomics.
Sims, David; Ponting, Chris P; Heger, Andreas
2016-01-01
How should the next generation of genomics scientists be trained while simultaneously pursuing high quality and diverse research? CGAT, the Computational Genomics Analysis and Training programme, was set up in 2010 by the UK Medical Research Council to complement its investment in next-generation sequencing capacity. CGAT was conceived around the twin goals of training future leaders in genome biology and medicine, and providing much needed capacity to UK science for analysing genome scale data sets. Here we outline the training programme employed by CGAT and describe how it dovetails with collaborative research projects to launch scientists on the road towards independent research careers in genomics. © The Author 2015. Published by Oxford University Press.
Kim, Michele M.; Penjweini, Rozhin; Gemmell, Nathan R.; Veilleux, Israel; McCarthy, Aongus; Buller, Gerald S.; Hadfield, Robert H.; Wilson, Brian C.; Zhu, Timothy C.
2016-01-01
Accurate photodynamic therapy (PDT) dosimetry is critical for the use of PDT in the treatment of malignant and nonmalignant localized diseases. A singlet oxygen explicit dosimetry (SOED) model has been developed for in vivo purposes. It involves the measurement of the key components in PDT—light fluence (rate), photosensitizer concentration, and ground-state oxygen concentration ([3O2])—to calculate the amount of reacted singlet oxygen ([1O2]rx), the main cytotoxic component in type II PDT. Experiments were performed in phantoms with the photosensitizer Photofrin and in solution using phosphorescence-based singlet oxygen luminescence dosimetry (SOLD) to validate the SOED model. Oxygen concentration and photosensitizer photobleaching versus time were measured during PDT, along with direct SOLD measurements of singlet oxygen and triplet state lifetime (τΔ and τt), for various photosensitizer concentrations to determine necessary photophysical parameters. SOLD-determined cumulative [1O2]rx was compared to SOED-calculated [1O2]rx for various photosensitizer concentrations to show a clear correlation between the two methods. This illustrates that explicit dosimetry can be used when phosphorescence-based dosimetry is not feasible. Using SOED modeling, we have also shown evidence that SOLD-measured [1O2]rx using a 523 nm pulsed laser can be used to correlate to singlet oxygen generated by a 630 nm laser during a clinical malignant pleural mesothelioma (MPM) PDT protocol by using a conversion formula. PMID:27929427
Kim, Michele M; Penjweini, Rozhin; Gemmell, Nathan R; Veilleux, Israel; McCarthy, Aongus; Buller, Gerald S; Hadfield, Robert H; Wilson, Brian C; Zhu, Timothy C
2016-12-06
Accurate photodynamic therapy (PDT) dosimetry is critical for the use of PDT in the treatment of malignant and nonmalignant localized diseases. A singlet oxygen explicit dosimetry (SOED) model has been developed for in vivo purposes. It involves the measurement of the key components in PDT-light fluence (rate), photosensitizer concentration, and ground-state oxygen concentration ([³ O ₂])-to calculate the amount of reacted singlet oxygen ([¹ O ₂] rx ), the main cytotoxic component in type II PDT. Experiments were performed in phantoms with the photosensitizer Photofrin and in solution using phosphorescence-based singlet oxygen luminescence dosimetry (SOLD) to validate the SOED model. Oxygen concentration and photosensitizer photobleaching versus time were measured during PDT, along with direct SOLD measurements of singlet oxygen and triplet state lifetime ( τ Δ and τ t ), for various photosensitizer concentrations to determine necessary photophysical parameters. SOLD-determined cumulative [¹ O ₂] rx was compared to SOED-calculated [¹ O ₂] rx for various photosensitizer concentrations to show a clear correlation between the two methods. This illustrates that explicit dosimetry can be used when phosphorescence-based dosimetry is not feasible. Using SOED modeling, we have also shown evidence that SOLD-measured [¹ O ₂] rx using a 523 nm pulsed laser can be used to correlate to singlet oxygen generated by a 630 nm laser during a clinical malignant pleural mesothelioma (MPM) PDT protocol by using a conversion formula.
Personnel neutron dosimetry using electrochemically etched CR-39 foils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hankins, D.E.; Homann, S.; Westermark, J.
1986-09-17
A personnel neutron dosimetry system has been developed based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This Cr-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. The dosimetry system employs an electrochemical etch procedure that be used to process large numbers of Cr-39 dosimeters. The etch procedure is suitable for operations where the number of personnelmore » requires that many CR-39 dosimeters be processed. Experience shows that one full-time technician can etch and evaluate 2000 foils per month. The energy response to neutrons is fairly flat from about 80 keV to 3.5 MeV, but drops by about a factor of three in the 13 to 16 MeV range. The sensitivity of the dosimetry system is about 7 tracks/cm/sup 2//mrem, with a background equivalent to about 8 mrem for new CR-39 foils. The limit of sensitivity is approximately 10 mrem. The dosimeter has a significant variation in directional dependence, dropping to about 20% at 90/sup 0/. This dosimeter has been used for personnel neutron dosimetry at the Lawrence Livermore National Laboratory for more tha 18 months. 6 refs., 23 figs., 2 tabs.« less
Antisocial personality disorder--stable and unstable subtypes.
Ullrich, Simone; Coid, Jeremy
2010-04-01
There have been criticisms that the criteria for antisocial personality disorder (ASPD) are over-dependent on criminal behavior. This study aimed to identify unrelated criteria of social and behavioral problems and instability, and to investigate their associations in a representative household sample of adults in the UK. Approximately one third of adults with ASPD did not fulfill any of the criteria for instability. They were less aggressive and involved in illegal activities but expressed less remorse for their behaviors. Instability in ASPD was mediated primarily through comorbid anxiety disorders and borderline personality disorder. The concept of Secondary Psychopathy, which has not generally been applied to ASPD, demonstrated many similarities to the unstable subtype.
Emotional Labour, Burnout and Job Satisfaction in UK Teachers: The Role of Workplace Social Support
ERIC Educational Resources Information Center
Kinman, Gail; Wray, Siobhan; Strange, Calista
2011-01-01
Although teaching has been described as a profoundly emotional activity, little is known about the emotional demands faced by teachers or how this impacts on their well-being. This study examined relationships between "emotional labour", burnout (emotional exhaustion, depersonalisation and personal accomplishment) and job satisfaction in…
ERIC Educational Resources Information Center
Pearce, Alison
2014-01-01
This article describes the discovery of action research by a "conscious incompetent" in higher education. The influences on the development of an action researcher's individual philosophy are discussed. These shape a specific investigation into the implementation of international staff exchange in a post-1992 UK university from the…
Medical School Personal Statements: A Measure of Motivation or Proxy for Cultural Privilege?
ERIC Educational Resources Information Center
Wright, Sarah
2015-01-01
Students from state schools are underrepresented in UK medical schools. Discussions often focus on deficient academic and motivational traits of state school students, rather than considering the effects of student support during the admissions process. This qualitative study explored student experiences of support from schools and families during…
ERIC Educational Resources Information Center
Terjesen, Siri; Vinnicombe, Susan; Freeman, Cheryl
2007-01-01
Purpose: Building on person-organisation fit and gender self-schema, this research aims to examine UK university final year students' perception of the importance of organisational attributes and their presence in three major graduate employers. This study also seeks to explore which organisational attributes attract Generation Y men and women to…
"Structural Transformation" as a Threshold Concept in University Teaching
ERIC Educational Resources Information Center
Kinchin, Ian M.; Miller, Norma L.
2012-01-01
In an attempt to reveal potential threshold concepts in the field of higher education pedagogy, groups of university teachers (in the UK and in Panama) were encouraged to develop personal reflection upon their conceptions of teaching. This was initiated through concept mapping activities. It was hoped that this would help participants to address…
Open Source as Appropriate Technology for Global Education
ERIC Educational Resources Information Center
Carmichael, Patrick; Honour, Leslie
2002-01-01
Economic arguments for the adoption of "open source" software in business have been widely discussed. In this paper we draw on personal experience in the UK, South Africa and Southeast Asia to forward compelling reasons why open source software should be considered as an appropriate and affordable alternative to the currently prevailing…
Doctoral Supervisors' and Supervisees' Responses to Co-Supervision
ERIC Educational Resources Information Center
Olmos-López, Pamela; Sunderland, Jane
2017-01-01
With the increasing demand for doctoral education, co-supervision, understood as the formally agreed supervision of a research student by two or more academics in doctoral programmes, has become common practice in postgraduate circles in the UK. If supervision with one supervisor is complex due to personal, academic, ethical and sometimes…
Learning to Lead: A Practitioner Perspective
ERIC Educational Resources Information Center
McMaster, Maddy
2014-01-01
This reflective essay presents a personal account of experiences and models that have shaped the development of the author as a leader in tertiary education. It is presented from the perspective of a practitioner whose career has led her through academic and administrative roles in Australian and UK institutions into her current position as…
Personal and Social Development in Post-compulsory Education in the UK and Mexico.
ERIC Educational Resources Information Center
Martin, Christopher
1996-01-01
Compares the role of post-compulsory technical education in less developed countries and in developed market economies. Argues that England, by displacing education with skill accreditation, has turned the student into an object of economic policy. Mexico remains focused on a crude program designed to "modernize" the "ignorant"…
The Implementation of Progress Files in Higher Education: Reflection as National Policy
ERIC Educational Resources Information Center
Clegg, Sue; Bradley, Sally
2006-01-01
Progress files, involving personal development planning (PDP), are becoming a feature of many higher education systems internationally. In the UK they will become mandatory for all undergraduate students from 2005. This presents a major implementation challenge, because while reflection has been a cornerstone of practice in some areas of higher…
The madness of Nietzsche: a misdiagnosis of the millennium?
Cybulska, E M
2000-08-01
This article represents a personal discussion about Nietzsche's mental illness, which formed part of a larger paper 'The masks of Nietzsche and eternal return of the repressed'. This was presented at the 6th Annual Conference of The Friedrich Nietzsche Society, September 1996, Manchester UK, as reported by Nussbaumer-Benz (1998).
What Students Value as Inspirational and Transformative Teaching
ERIC Educational Resources Information Center
Bradley, Sally; Kirby, Emma; Madriaga, Manuel
2015-01-01
Evidence presented here stems from an analysis of student comments derived from a student-nominated inspirational teaching awards scheme at a large university in the United Kingdom (UK). There is a plethora of literature on teaching excellence and the scholarship of teaching, frequently based upon portfolios or personal claims of excellence, and…
Jones, Alison; Jones, Kelly; Holmes, Sheila; Ewers, Leon; Cabianca, Tiberio
2013-03-01
The aim of this work is to assess the possible radiological impact on the population of the United Kingdom (UK) from new nuclear power stations proposed for up to eight sites in England and Wales. The radiological impact was measured in terms of collective dose to the UK, European and world populations from a single year's discharge integrated to 500 and 100 000 years and the annual dose to an average member of the UK population (known as the per-caput dose). The doses were calculated for two reactor types, UK EPR™ and AP1000™, using the annual expected discharges estimated by the designers of the reactors and assuming two reactors per site. In addition, typical individual doses to adults living close to the sites were calculated on the basis of continuous discharges for 60 years (the assumed lifetime of the reactors). The dose to a representative person (previously known as the critical group) was not calculated, as this has been done elsewhere. The assessments were carried out using the software program PC-CREAM 08(®) which implements the updated European Commission methodology for assessing the radiological impact of routine releases of radionuclides to the environment. The collective dose truncated to 500 years to the UK population was estimated to be 0.5 manSv assuming UK EPR reactors on all sites and 0.6 manSv assuming AP1000s on three sites with UK EPRs on the other sites. The most significant contribution to the collective dose to the UK population is due to the global circulation of carbon-14 released to the atmosphere. The annual dose to an average member of the UK population from all sites was calculated to be around 10 nSv y(-1) and would therefore contribute little to an individual's total radiation dose. All the calculated doses to a typical adult living near the sites assuming continuous discharges for 60 years were found to be below 1 μSv y(-1).
Sigafoos, Jennifer
2013-01-01
Preliminary references to the Court of Justice for the European Union are unevenly distributed across the EU, creating differing access to justice for European citizens. This study presents case studies of the UK and France, exploring factors affecting rates of social policy preliminary references from 1996–2009. The UK had a rate twice that of France. What accounts for this difference? Analysis of documentary evidence and 25 expert interviews help to explain the differing rates. Themes were related to policy, structural factors and the agency of actors. In the UK, policy themes are the free movement of persons and the ‘Right to Reside’ test. Legal aid and legal NGOs help individuals access the Court and drive test case strategies. In France, a high degree of dualisation in the welfare state creates an insider/outsider dynamic. Coupled with the resistance of courts and a lack of comparable actors to drive preliminary references, this contributes to a lower rate of references. PMID:23565042
Hill, Andrew; Hill, Teresa; Jose, Sophie; Pozniak, Anton
2014-01-01
In other disease areas, generic drugs are normally used after patent expiry. Patents on zidovudine, lamivudine, nevirapine and efavirenz have already expired. Patents will expire for abacavir in late 2014, lopinavir/r in 2016, and tenofovir, darunavir and atazanavir in 2017. However, patents on single-tablet regimens do not expire until after 2026. The number of people taking each antiretroviral in the UK was estimated from 23,655 individuals in the UK CHIC cohort (2012 database). Costs of patented drugs were taken from the British National Formulary database, assuming a 30% discount. Costs of generic antiretrovirals were estimated using an 80% discount from patented prices, or actual costs where available. Two options were analysed: 1 - all patients use single-tablet regimens and patented versions of drugs; prices remain stable over time; 2 - all people switch from patented to generic drugs when available, after patent expiry (dates shown above). There were an estimated 67,000 people taking antiretrovirals in the UK in 2014, estimated to rise by 8% per year until 2018 (in line with previous rises). The most widely used antiretrovirals in the CHIC cohort were tenofovir (TDF) (75%), emtricitabine (FTC) (69%), efavirenz (EFV) (39%), lamivudine (3TC) (23%), abacavir (ABC) (18%), darunavir (DRV) (21%) and atazanavir (ATV) (16%). The predicted annual UK cost of generic ABC/3TC/EFV (three generic tablets once daily) was £1018 per person-year. Costs of patented single-tablet regimens ranged from £5000 to £7500 per person-year. Assuming continued use of patented antiretrovirals in the UK, the predicted total national costs of antiretroviral treatment were predicted to rise from £425 million in 2014 to £459 m in 2015, £495 m in 2016, £536 m in 2017 and £578 m in 2018. With a 100% switch to generics, total predicted costs were £337 m in 2014, £364 m in 2015, £382 m in 2016, £144 m in 2017 and £169 m in 2018. The total predicted saving over five years from a switch to generics was £1.1 billion. Systematic switching from patented to generic antiretrovirals could potentially save approximately £1.1 billion in the UK over the next five years, compared with continued use of patented versions: this money could be spent on urgently needed HIV prevention programmes. Similar savings are feasible for other European countries, given parallel patent expiry dates. More detailed economic evaluation is required to show when patented single-tablet regimens provide value for money, compared to bioequivalent generic versions of 3-4 pills once daily.
Speakman, Mark; Kirby, Roger; Doyle, Scott; Ioannou, Chris
2015-04-01
Lower urinary tract symptoms (LUTS) associated with benign prostatic hyperplasia (BPH) can be bothersome and negatively impact on a patient's quality of life (QoL). As the prevalence of LUTS/BPH increases with age, the burden on the healthcare system and society may increase due to the ageing population. This review unifies literature on the burden of LUTS/BPH on patients and society, particularly in the UK. LUTS/BPH is associated with high personal and societal costs, both in direct medical costs and indirect losses in daily functioning, and through its negative impact on QoL for patients and partners. LUTS/BPH is often underdiagnosed and undertreated. Men should be encouraged to seek medical advice for this condition and should not accept it as part of ageing, while clinicians should be more active in the identification and treatment of LUTS/BPH. To assess the burden of illness and unmet need arising from lower urinary tract symptoms (LUTS) presumed secondary to benign prostatic hyperplasia (BPH) from an individual patient and societal perspective with a focus on the UK. Embase, PubMed, the World Health Organization, the Cochrane Database of Systematic Reviews and the York Centre for Reviews and Dissemination were searched to identify studies on the epidemiological, humanistic or economic burden of LUTS/BPH published in English between October 2001 and January 2013. Data were extracted and the quality of the studies was assessed for inclusion. UK data were reported; in the absence of UK data, European and USA data were provided. In all, 374 abstracts were identified, 104 full papers were assessed and 33 papers met the inclusion criteria and were included in the review. An additional paper was included in the review upon a revision in 2014. The papers show that LUTS are common in the UK, affecting ≈3% of men aged 45-49 years, rising to >30% in men aged ≥85 years. European and USA studies have reported the major impact of LUTS on quality of life of the patient and their partner. LUTS are associated with high personal and societal costs, both in direct medical costs and indirect losses in daily functioning. While treatment costs in the UK are relatively low compared with other countries, the burden on health services is still substantial. LUTS associated with BPH is a highly impactful condition that is often undertreated. LUTS/BPH have a major impact on men, their families, health services and society. Men with LUTS secondary to BPH should not simply accept their symptoms as part of ageing, but should be encouraged to consult their physicians if they have bothersome symptoms. © 2014 The Authors. BJU International © 2014 BJU International.
ESR/Alanine gamma-dosimetry in the 10-30 Gy range.
Fainstein, C; Winkler, E; Saravi, M
2000-05-01
We report Alanine Dosimeter preparation, procedures for using the ESR/Dosimetry method, and the resulting calibration curve for gamma-irradiation in the range from 10-30 Gy. We use calibration curve to measure the irradiation dose in gamma-irradiation of human blood, as required in Blood Transfusion Therapy. The ESR/Alanine results are compared against those obtained using the thermoluminescent dosimetry (TLD) method.
1993-12-01
on Panasonic TLD . Panasonic Industrial Company; Secaucus, New Jersey. 5. Thurlow, Ronald M. "Neutron Dosimetry Using a Panasonic Thermoluminescent...Radiation Dosimetry Branch Brooks Air Force Base San Antonio, Texas 78235 Final Report for: AFOSR Summer Research Program Armstrong Laboratory Sponsored...Associate Radiation Dosimetry Branch Armstrong Laboratory Abstract In an attempt to improve personnel monitoring for neutron emissions, Panasonic has
DiLauro, Michelle; Pereira, Amanda; Carr, Jennifer; Chiu, Mary; Wesson, Virginia
2015-02-20
Spousal caregivers of persons with dementia often have difficulty engaging persons with dementia in leisure activities. This qualitative descriptive study identifies how caregivers perceive their spouses' participation in leisure activities since dementia onset and the professional guidance caregivers require to increase persons with dementia participation in shared leisure activities. Nine spousal caregivers from a hospital-based caregiver intervention attended one of three focus groups. Using symbolic interactionism and selective optimization with compensation theory as guiding frameworks, thematic content analysis was performed. Three major themes were identified: Recognizing and acknowledging changes, Making sense of changes and conflicts, and Embracing changes and forging ahead. Findings can be used by healthcare providers to better understand caregivers' needs for engaging persons with dementia in shared leisure activities, and inform development of feedback protocols to enhance caregiver interventions. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Dosimetry procedures for an industrial irradiation plant
NASA Astrophysics Data System (ADS)
Grahn, Ch.
Accurate and reliable dosimetry procedures constitute a very important part of process control and quality assurance at a radiation processing plant. γ-Dose measurements were made on the GBS 84 irradiator for food and other products on pallets or in containers. Chemical dosimeters wre exposed in the facility under conditions of the typical plant operation. The choice of the dosimeter systems employed was based on the experience in chemical dosimetry gained over several years. Dose uniformity information was obtained in air, spices, bulbs, feeds, cosmetics, plastics and surgical goods. Most products currently irradiated require dose uniformity which can be efficiently provided by pallet or box irradiators like GBS 84. The radiation performance characteristics and some dosimetry procedures are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C.A. Baldwin; F.B.K. Kam; I. Remec
1998-10-01
This report describes the computational methodology for the least-squares adjustment of the dosimetry data from the HSSI 10.OD dosimetry capsule with neutronics calculations. It presents exposure rates at each dosimetry location for the neutron fluence greater than 1.0 MeV, fluence greater than 0.1 MeV, and displacements per atom. Exposure parameter distributions are also described in terms of three- dimensional fitting functions. When fitting functions are used it is suggested that an uncertainty of 6% (1 o) should be associated with the exposure rate values. The specific activity of each dosimeter at the end of irradiation is listed in the Appendix.
Dosimetric Considerations in Radioimmunotherapy and Systemic Radionuclide Therapies: A Review
Loke, Kelvin S. H.; Padhy, Ajit K.; Ng, David C. E.; Goh, Anthony S.W.; Divgi, Chaitanya
2011-01-01
Radiopharmaceutical therapy, once touted as the “magic bullet” in radiation oncology, is increasingly being used in the treatment of a variety of malignancies; albeit in later disease stages. With ever-increasing public and medical awareness of radiation effects, radiation dosimetry is becoming more important. Dosimetry allows administration of the maximum tolerated radiation dose to the tumor/organ to be treated but limiting radiation to critical organs. Traditional tumor dosimetry involved acquiring pretherapy planar scans and plasma estimates with a diagnostic dose of intended radiopharmaceuticals. New advancements in single photon emission computed tomography and positron emission tomography systems allow semi-quantitative measurements of radiation dosimetry thus allowing treatments tailored to each individual patient. PMID:22144871
Millett, Elizabeth R. C.; Quint, Jennifer K.; Smeeth, Liam; Daniel, Rhian M.; Thomas, Sara L.
2013-01-01
Community-acquired lower respiratory tract infections (LRTI) and pneumonia (CAP) are common causes of morbidity and mortality among those aged ≥65 years; a growing population in many countries. Detailed incidence estimates for these infections among older adults in the United Kingdom (UK) are lacking. We used electronic general practice records from the Clinical Practice Research Data link, linked to Hospital Episode Statistics inpatient data, to estimate incidence of community-acquired LRTI and CAP among UK older adults between April 1997-March 2011, by age, sex, region and deprivation quintile. Levels of antibiotic prescribing were also assessed. LRTI incidence increased with fluctuations over time, was higher in men than women aged ≥70 and increased with age from 92.21 episodes/1000 person-years (65-69 years) to 187.91/1000 (85-89 years). CAP incidence increased more markedly with age, from 2.81 to 21.81 episodes/1000 person-years respectively, and was higher among men. For both infection groups, increases over time were attenuated after age-standardisation, indicating that these rises were largely due to population aging. Rates among those in the most deprived quintile were around 70% higher than the least deprived and were generally higher in the North of England. GP antibiotic prescribing rates were high for LRTI but lower for CAP (mostly due to immediate hospitalisation). This is the first study to provide long-term detailed incidence estimates of community-acquired LRTI and CAP in UK older individuals, taking person-time at risk into account. The summary incidence commonly presented for the ≥65 age group considerably underestimates LRTI/CAP rates, particularly among older individuals within this group. Our methodology and findings are likely to be highly relevant to health planners and researchers in other countries with aging populations. PMID:24040394
Ma, Bernice Hua; Yong, Hua‐Hie; McNeill, Ann; Hitchman, Sara C.
2017-01-01
Abstract Introduction and Aims. Personal vaporisers (PV), including e‐cigarettes, may be a harm reduction strategy for tobacco control. This study aims to identify factors associated with future intentions to vape among smokers and ex‐smokers in Australia and the UK. Design and Methods. Cross‐sectional data of smokers and ex‐smokers (n = 1199, mean age = 45.3 years, 44.8% male), collected in 2014/2015 and divided into four subgroups: smoking past vapers (SPV), smoking vapers (SV), ex‐smoking past vapers (ESPV) and ex‐smoking vapers (ESV), from the International Tobacco Control Australia and UK surveys were analysed by using regression models. Results. Higher vaping satisfaction increased vaping intentions for all groups except ESPV. Perceiving PVs as less harmful predicted intentions to vape for all groups except ESV. The importance of PVs for stopping smoking predicted lower intentions to continue vaping for SV, but higher intentions to initiate vaping for SPV. The importance of PVs for cutting down smoking was a positive predictor only for SPV. Among ex‐smokers, importance for maintaining not smoking was a positive predictor for ESPV, but not for ESV. The importance of perceiving vapour being less harmful also depended on vaping status for ex‐smokers. The only country interaction was that only in the UK was perceiving PVs as less harmful associated with intention among SPV. Discussion and Conclusion. Factors influencing intentions vary by smoking and/or vaping status, with greater differences between the ex‐smoker subgroups. This is consistent with PVs being seen as a way of managing smoking, rather than something that has intrinsic value, for all except the ex‐smoking vapers. [Ma BH, Yong H‐H, Borland R, McNeill A, Hitchman SC. Factors associated with future intentions to use personal vaporisers among those with some experience of vaping. Drug Alcohol Rev 2017;00:000–000] PMID:28560806
Ma, Bernice Hua; Yong, Hua-Hie; Borland, Ron; McNeill, Ann; Hitchman, Sara C
2018-02-01
Personal vaporisers (PV), including e-cigarettes, may be a harm reduction strategy for tobacco control. This study aims to identify factors associated with future intentions to vape among smokers and ex-smokers in Australia and the UK. Cross-sectional data of smokers and ex-smokers (n = 1199, mean age = 45.3 years, 44.8% male), collected in 2014/2015 and divided into four subgroups: smoking past vapers (SPV), smoking vapers (SV), ex-smoking past vapers (ESPV) and ex-smoking vapers (ESV), from the International Tobacco Control Australia and UK surveys were analysed by using regression models. Higher vaping satisfaction increased vaping intentions for all groups except ESPV. Perceiving PVs as less harmful predicted intentions to vape for all groups except ESV. The importance of PVs for stopping smoking predicted lower intentions to continue vaping for SV, but higher intentions to initiate vaping for SPV. The importance of PVs for cutting down smoking was a positive predictor only for SPV. Among ex-smokers, importance for maintaining not smoking was a positive predictor for ESPV, but not for ESV. The importance of perceiving vapour being less harmful also depended on vaping status for ex-smokers. The only country interaction was that only in the UK was perceiving PVs as less harmful associated with intention among SPV. Factors influencing intentions vary by smoking and/or vaping status, with greater differences between the ex-smoker subgroups. This is consistent with PVs being seen as a way of managing smoking, rather than something that has intrinsic value, for all except the ex-smoking vapers. [Ma BH, Yong H-H, Borland R, McNeill A, Hitchman SC. Factors associated with future intentions to use personal vaporisers among those with some experience of vaping. Drug Alcohol Rev 2017;00:000-000]. © 2017 The Authors Drug and Alcohol Review published by John Wiley & Sons Australia, Ltd on behalf of Australasian Professional Society on Alcohol and other Drugs.
Migrants and HIV stigma: findings from the Stigma Index Study (UK).
Chinouya, Martha; Hildreth, Anthony; Goodall, Deborah; Aspinall, Peter; Hudson, Alistair
2017-01-01
This paper is based on data collected in 2009 for the international Stigma Index Study which measured the experiences of stigma among participants living with HIV in the UK. Data were collected using a self-completed survey questionnaire and focus group discussions. Quantitative data were analysed using SPSS, while qualitative data were subjected to thematic analysis. The Stigma Index attempts to establish a baseline for documenting the experience of stigma and discrimination by people living with HIV while also acting as an advocacy tool whose power lay in the involvement of people living with HIV in the design of study instruments and data collection. Participants were recruited through collaborations with a broad range of UK HIV support organisations. The ethics protocols used were those described in the Stigma Index guidebook. A total of 867 people living with HIV took part, of whom 276 described themselves as 'immigrants'. Most of this 'migrant' subsample (70%) was women. Nearly, all (91%) identified as heterosexual, while 9% were attracted to someone of the same sex as them. Socioeconomic deprivation was a key theme and they reported other stigmatised chronic conditions in addition to HIV. It is not possible to ascertain from the questionnaire, the migrants' countries of origin and length of stay in the UK. Control of information about HIV was critically managed, with respect to family and partners. Felt stigma increased anxieties about personal safety, particularly among men. Strategies for safeguarding against the negative impact of stigma included avoiding social gatherings, intimacy, and clinical and HIV social care settings. Most participants were unaware of policies and declarations that protected them as persons living with HIV. Specific recommendations include creating awareness about rights as enshrined in various legal frameworks that protect the right of people living with HIV, which has been reconfigured as a 'disability'. © 2014 John Wiley & Sons Ltd.
Meisel, Susanne F; Side, Lucy; Gessler, Sue; Hann, Katie E J; Wardle, Jane; Lanceley, Anne
2017-01-01
Background Genetic risk assessment for breast cancer and ovarian cancer (BCOC) is expected to make major inroads into mainstream clinical practice. It is important to evaluate the potential impact on women ahead of its implementation in order to maximise health benefits, as predictive genetic testing without adequate support could lead to adverse psychological and behavioural responses to risk disclosure. Objective To examine anticipated health behaviour changes and perceived control to disclosure of genetic risk for BCOC and establish demographic and person-specific correlates of adverse anticipated responses in a population-based sample of women. Design Cross-sectional quantitative survey study carried out by the UK Office for National Statistics in January and March 2014. Setting Face-to-face computer-assisted interviews conducted by trained researchers in participants’ homes. Participants 837 women randomly chosen from households across the UK identified from the Royal Mail’s Postcode Address File. Outcome measures Anticipated health behaviour change and perceived control to disclosure of BCOC risk. Results In response to a genetic test result, most women (72%) indicated ‘I would try harder to have a healthy lifestyle’, and over half (55%) felt ‘it would give me more control over my life’. These associations were independent of demographic factors or perceived risk of BCOC in Bonferroni-corrected multivariate analyses. However, a minority of women (14%) felt ‘it isn’t worth making lifestyle changes’ and that ‘I would feel less free to make choices in my life’ (16%) in response to BCOC risk disclosure. The former belief was more likely to be held by women who were educated below university degree level (P<0.001) after adjusting for other demographic and person-specific correlates. Conclusion These findings indicate that women in the UK largely anticipate that they would engage in positive health behaviour changes in response to BCOC risk disclosure. PMID:29275340
Gourlay, Annabelle; Fox, Julie; Gafos, Mitzy; Fidler, Sarah; Nwokolo, Nneka; Clarke, Amanda; Gilson, Richard; Orkin, Chloe; Collins, Simon; Porter, Kholoud; Hart, Graham
2017-01-01
Objectives A key UK public health priority is to reduce HIV incidence among gay and other men who have sex with men (MSM). This study aimed to explore the social and environmental context in which new HIV infections occurred among MSM in London and Brighton in 2015. Design A qualitative descriptive study, comprising in-depth interviews, was carried out as a substudy to the UK Register of HIV Seroconverters cohort: an observational cohort of individuals whose date of HIV seroconversion was well estimated. An inductive thematic analysis was conducted in NVivo, guided by a socio-ecological framework. Setting Participants were recruited from six HIV clinics in London and Brighton. Fieldwork was conducted between January and April 2015. Participants All MSM eligible for the UK Register Seroconverter cohort (an HIV-positive antibody test result within 12 months of their last documented HIV-negative test or other laboratory evidence of HIV seroconversion) diagnosed within the past 12 months and aged ≥18 were eligible for the qualitative substudy. 21 MSM participated, aged 22–61 years and predominantly white. Results A complex interplay of factors, operating at different levels, influenced risk behaviours and HIV acquisition. Participants saw risk as multi-factorial, but the relative importance of factors varied for each person. Individual psycho-social factors, including personal history, recent life stressors and mental health, enhanced vulnerability towards higher risk situations, while features of the social environment, such as chemsex and social media, and prevalent community beliefs regarding treatment and HIV normalisation, encouraged risk taking. Conclusions Recently acquired HIV infection among MSM reflects a complex web of factors operating at different levels. These findings point to the need for multi-level interventions to reduce the risk of HIV acquisition among high-risk MSM in the UK and similar settings. PMID:28851787
Initial Nuclear Radiation Hardness Validation Test
2008-11-03
d. Dosimetry from the GDR environment. The TLDs should be placed as indicated in the section above and their location used to determine the... electronics to levels which will account for: all error terms in dosimetry and data recording, response differences in microcircuits due to different...the internal gamma dose environment of an LRU. d. Dosimetry from the gamma dose environment. The TLDs should be placed as indicated in the
1991-09-01
2 2. Dosimetry ............................................. 4 C. OVERVIEW OF EXPERIMENT............................... 5 11. ELECTRON BEAM...From these measurements, the dose was calculated and then compared to a measured dose obtained from TLD dosimetry . Technical 5 problems with the...LINAC precluded TLD dosimetry from being accomplished during the first run and, therefore, was performed on the second run only. After irradiation, a NaI
Improvement and Analysis of the Radiation Response of RADFET Dosimeters
1992-06-15
TLD ), silicon p-i-n diode responses and silicon calorimetry (AWE Dosimetry Service). Intensive preparations were made by REM and the experiments were...SUB-GROUP dose: RADFET : tactical dosimetry silicon : metal-oxide- 0705 emiconductor (MOS) field effect transistor (FET) : silicon Idioxide space...1.1 Principle of a dosimetry system, based on the RADFET (radiation-sensitive field-effect transistor) (a) microscopic cross-section of chip (b) chip
Characterization of the Radiological Environment at J-Village during Operation Tomodachi
2013-02-01
individual as compared to those for the helicopter crew members (Appendix A). 3.2.2. Other Relevant Dosimetry Results Thermoluminescent dosimeter ( TLD ...internal monitoring results are available for 14 of these individuals. External dosimetry data (EPD and TLD ) showed that the maximum recorded dose for an...Washington, DC. http://www.NNSAResponseData.net. Accessed December 7. USAFCRD (U. S. Air Force Center for Radiation Dosimetry ), 2011. Electronic Pocket
AFRRI Reports, April-June 1990
1990-07-01
described in detail in the companion paper (4). In vivo dosimetry was done using Harshaw (Solon, Ohio) TLD -100 lith- ium fluoride thermoluminescent...provide replicate measurements. Two separate dosimetry tubes were developed (Fig. 1). The first contained 30 TLD cap- sules loaded in a 90-cm length...situ Dosimetry Tube 55 3 LIF TLDs In gelatin capsule TUBEB LIF TLDs Nylon Balls Steel Ball Epoxy Plug I Scale 3 cm - J FIG. I
The Effect of Irradiation on Bone Remodelling and the Structural Integrity of the Vertebral Column
1990-01-01
thermoluminescent dosimetry calculations were also used. Seventy-four lithium fluoride thermoluminescent dosimeters ( TLDs ) were selected from 120...and thermoluminescent dosimetry ( TLD ) were used to evaluate the actual doses administered. The TLD analysis was completed with five strips of five...professional help with the dose administration and the dosimetry . And especially to my husband. Kevin, without whose help and encouragement I could not have
[Automatic Extraction and Analysis of Dosimetry Data in Radiotherapy Plans].
Song, Wei; Zhao, Di; Lu, Hong; Zhang, Biyun; Ma, Jun; Yu, Dahai
To improve the efficiency and accuracy of extraction and analysis of dosimetry data in radiotherapy plans for a batch of patients. With the interface function provided in Matlab platform, a program was written to extract the dosimetry data exported from treatment planning system in DICOM RT format and exported the dose-volume data to an Excel file with the SPSS compatible format. This method was compared with manual operation for 14 gastric carcinoma patients to validate the efficiency and accuracy. The output Excel data were compatible with SPSS in format, the dosimetry data error for PTV dose interval of 90%-98%, PTV dose interval of 99%-106% and all OARs were -3.48E-5 ± 3.01E-5, -1.11E-3 ± 7.68E-4, -7.85E-5 ± 9.91E-5 respectively. Compared with manual operation, the time required was reduced from 5.3 h to 0.19 h and input error was reduced from 0.002 to 0. The automatic extraction of dosimetry data in DICOM RT format for batch patients, the SPSS compatible data exportation, quick analysis were achieved in this paper. The efficiency of clinical researches based on dosimetry data analysis of large number of patients will be improved with this methods.
Time resolved dosimetry of human brain exposed to low frequency pulsed magnetic fields.
Paffi, Alessandra; Camera, Francesca; Lucano, Elena; Apollonio, Francesca; Liberti, Micaela
2016-06-21
An accurate dosimetry is a key issue to understanding brain stimulation and related interaction mechanisms with neuronal tissues at the basis of the increasing amount of literature revealing the effects on human brain induced by low-level, low frequency pulsed magnetic fields (PMFs). Most literature on brain dosimetry estimates the maximum E field value reached inside the tissue without considering its time pattern or tissue dispersivity. Nevertheless a time-resolved dosimetry, accounting for dispersive tissues behavior, becomes necessary considering that the threshold for an effect onset may vary depending on the pulse waveform and that tissues may filter the applied stimulatory fields altering the predicted stimulatory waveform's size and shape. In this paper a time-resolved dosimetry has been applied on a realistic brain model exposed to the signal presented in Capone et al (2009 J. Neural Transm. 116 257-65), accounting for the broadband dispersivity of brain tissues up to several kHz, to accurately reconstruct electric field and current density waveforms inside different brain tissues. The results obtained by exposing the Duke's brain model to this PMF signal show that the E peak in the brain is considerably underestimated if a simple monochromatic dosimetry is carried out at the pulse repetition frequency of 75 Hz.
A multicentre 'end to end' dosimetry audit for cervix HDR brachytherapy treatment.
Palmer, Antony L; Diez, Patricia; Gandon, Laura; Wynn-Jones, Andrea; Bownes, Peter; Lee, Chris; Aird, Edwin; Bidmead, Margaret; Lowe, Gerry; Bradley, David; Nisbet, Andrew
2015-02-01
To undertake the first multicentre fully 'end to end' dosimetry audit for HDR cervix brachytherapy, comparing planned and delivered dose distributions around clinical treatment applicators, with review of local procedures. A film-dosimetry audit was performed at 46 centres, including imaging, applicator reconstruction, treatment planning and delivery. Film dose maps were calculated using triple-channel dosimetry and compared to RTDose data from treatment planning systems. Deviations between plan and measurement were quantified at prescription Point A and using gamma analysis. Local procedures were also discussed. The mean difference between planned and measured dose at Point A was -0.6% for plastic applicators and -3.0% for metal applicators, at standard uncertainty 3.0% (k=1). Isodose distributions agreed within 1mm over a dose range 2-16Gy. Mean gamma passing rates exceeded 97% for plastic and metal applicators at 3% (local) 2mm criteria. Two errors were found: one dose normalisation error and one applicator library misaligned with the imaged applicator. Suggestions for quality improvement were also made. The concept of 'end to end' dosimetry audit for HDR brachytherapy has been successfully implemented in a multicentre environment, providing evidence that a high level of accuracy in brachytherapy dosimetry can be achieved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Time resolved dosimetry of human brain exposed to low frequency pulsed magnetic fields
NASA Astrophysics Data System (ADS)
Paffi, Alessandra; Camera, Francesca; Lucano, Elena; Apollonio, Francesca; Liberti, Micaela
2016-06-01
An accurate dosimetry is a key issue to understanding brain stimulation and related interaction mechanisms with neuronal tissues at the basis of the increasing amount of literature revealing the effects on human brain induced by low-level, low frequency pulsed magnetic fields (PMFs). Most literature on brain dosimetry estimates the maximum E field value reached inside the tissue without considering its time pattern or tissue dispersivity. Nevertheless a time-resolved dosimetry, accounting for dispersive tissues behavior, becomes necessary considering that the threshold for an effect onset may vary depending on the pulse waveform and that tissues may filter the applied stimulatory fields altering the predicted stimulatory waveform’s size and shape. In this paper a time-resolved dosimetry has been applied on a realistic brain model exposed to the signal presented in Capone et al (2009 J. Neural Transm. 116 257-65), accounting for the broadband dispersivity of brain tissues up to several kHz, to accurately reconstruct electric field and current density waveforms inside different brain tissues. The results obtained by exposing the Duke’s brain model to this PMF signal show that the E peak in the brain is considerably underestimated if a simple monochromatic dosimetry is carried out at the pulse repetition frequency of 75 Hz.
Self-report and long-term field measures of MP3 player use: how accurate is self-report?
Portnuff, C D F; Fligor, B J; Arehart, K H
2013-02-01
This study was designed to evaluate the usage patterns of portable listening device (PLD) listeners, and the relationships between self-report measures and long-term dosimetry measures of listening habits. This study used a descriptive correlational design. Participants (N = 52) were 18-29 year old men and women who completed surveys. A randomly assigned subset (N = 24) of participants had their listening monitored by dosimetry for one week. Median weekly noise doses reported and measured through dosimetry were low (9-93%), but 14.3% of participants reported exceeding a 100% noise dose weekly. When measured by dosimetry, 16.7% of participants exceeded a 100% noise dose weekly. The self-report question that best predicted the dosimetry-measured dose asked participants to report listening duration and usual listening level on a visual-analog scale. This study reports a novel dosimetry system that can provide accurate measures of PLD use over time. When not feasible, though, the self-report question described could provide a useful research or clinical tool to estimate exposure from PLD use. Among the participants in this study, a small but substantial percentage of PLD users incurred exposure from PLD use alone that increases their risk of music-induced hearing loss.
Hyper-realistic face masks: a new challenge in person identification.
Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob
2017-01-01
We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williamson, Jeffrey F.
This paper briefly reviews the evolution of brachytherapy dosimetry from 1900 to the present. Dosimetric practices in brachytherapy fall into three distinct eras: During the era of biological dosimetry (1900-1938), radium pioneers could only specify Ra-226 and Rn-222 implants in terms of the mass of radium encapsulated within the implanted sources. Due to the high energy of its emitted gamma rays and the long range of its secondary electrons in air, free-air chambers could not be used to quantify the output of Ra-226 sources in terms of exposure. Biological dosimetry, most prominently the threshold erythema dose, gained currency as amore » means of intercomparing radium treatments with exposure-calibrated orthovoltage x-ray units. The classical dosimetry era (1940-1980) began with successful exposure standardization of Ra-226 sources by Bragg-Gray cavity chambers. Classical dose-computation algorithms, based upon 1-D buildup factor measurements and point-source superposition computational algorithms, were able to accommodate artificial radionuclides such as Co-60, Ir-192, and Cs-137. The quantitative dosimetry era (1980- ) arose in response to the increasing utilization of low energy K-capture radionuclides such as I-125 and Pd-103 for which classical approaches could not be expected to estimate accurate correct doses. This led to intensive development of both experimental (largely TLD-100 dosimetry) and Monte Carlo dosimetry techniques along with more accurate air-kerma strength standards. As a result of extensive benchmarking and intercomparison of these different methods, single-seed low-energy radionuclide dose distributions are now known with a total uncertainty of 3%-5%.« less
Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification
NASA Astrophysics Data System (ADS)
Vandecasteele, Jan; De Deene, Yves
2013-09-01
A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detector measurement that served as golden standard. Both gel dosimeters were found accurate within 4% accuracy. In the 3D dose matrix of the radiochromic gel, hotspot dose deviations up to 8% were observed which are attributed to the fabrication procedure. The polymer gel readout was shown to be sensitive to B0 field and B1 field non-uniformities as well as temperature variations during scanning. The performance of the two gel dosimeters was also evaluated for a brain tumour IMRT treatment. Both gel measured dose distributions were compared against treatment planning system predicted dose maps which were validated independently with ion chamber measurements and portal dosimetry. In the radiochromic gel measurement, two sources of deviations could be identified. Firstly, the dose in a cluster of voxels near the edge of the phantom deviated from the planned dose. Secondly, the presence of dose hotspots in the order of 10% related to inhomogeneities in the gel limit the clinical acceptance of this dosimetry technique. Based on the results of the micelle gel dosimeter prototype presented here, chemical optimization will be subject of future work. Polymer gel dosimetry is capable of measuring the absolute dose in the whole 3D volume within 5% accuracy. A temperature stabilization technique is incorporated to increase the accuracy during short measurements, however keeping the temperature stable during long measurement times in both calibration phantoms and the volumetric phantom is more challenging. The sensitivity of MRI readout to minimal temperature fluctuations is demonstrated which proves the need for adequate compensation strategies.
TH-A-204-02: Part II - Worldwide Radiation Metrology
DOE Office of Scientific and Technical Information (OSTI.GOV)
McEwen, M.
The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair inmore » dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.« less
Twenty new ISO standards on dosimetry for radiation processing
NASA Astrophysics Data System (ADS)
Farrar, H., IV
2000-03-01
Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products — Requirements for validation and routine control — Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have not yet been submitted to the ISO, and six more dosimetry standards are under development.
Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G
2003-01-01
To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (p<0.001), and the 1-month CT volume was 43.6 cm(3) (p<0.001). The mean difference between the OR dose received by 90% of the prostate (D(90)) and the CT D(90) was 3.4% (95% confidence interval, 2.5-6.6%; p=0.034). The mean dose to 30% of the urethra was 120% of prescription in the OR and 138% on CT. The mean difference was 18% (95% confidence interval, 13-24%; p<0.001). Although small differences exist between the OR and CT dosimetry results, these data suggest that this intraoperative implant dosimetric representation system provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.
Velikyan, Irina; Antoni, Gunnar; Sörensen, Jens; Estrada, Sergio
2013-01-01
Positron Emission Tomography (PET) and in particular gallium-68 (68Ga) applications are growing exponentially worldwide contributing to the expansion of nuclear medicine and personalized management of patients. The significance of 68Ga utility is reflected in the implementation of European Pharmacopoeia monographs. However, there is one crucial point in the monographs that might limit the use of the generators and consequently expansion of 68Ga applications and that is the limit of 0.001% of Germanium-68 (68Ge(IV)) radioactivity content in a radiopharmaceutical. We have investigated the organ distribution of 68Ge(IV) in rat and estimated human dosimetry parameters in order to provide experimental evidence for the determination and justification of the 68Ge(IV) limit. Male and female rats were injected in the tail vein with formulated [68Ge]GeCl4 in the absence or presence of [68Ga]Ga-DOTA-TOC. The tissue radioactivity distribution data was extrapolated for the estimation of human organ equivalent doses and total effective dose using Organ Level Internal Dose Assessment Code software (OLINDA/EXM). 68Ge(IV) was evenly distributed among the rat organs and fast renal excretion prevailed. Human organ equivalent dose and total effective dose estimates indicated that the kidneys were the dose-limiting organs (185±54 μSv/MBq for female and 171±38 μSv/MBq for male) and the total effective dose was 15.5±0.1 and 10.7±1.2 μSv/MBq, respectively for female and male. The results of this dosimetry study conclude that the 68Ge(IV) limit currently recommended by monographs could be increased considerably (>100 times) without exposing the patient to harm given the small absorbed doses to normal organs and fast excretion. PMID:23526484
A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.
Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I
2013-12-01
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
Thermoluminescence glow curve analysis and CGCD method for erbium doped CaZrO{sub 3} phosphor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tiwari, Ratnesh, E-mail: 31rati@gmail.com; Chopra, Seema
2016-05-06
The manuscript report the synthesis, thermoluminescence study at fixed concentration of Er{sup 3+} (1 mol%) doped CaZrO{sub 3} phosphor. The phosphors were prepared by modified solid state reaction method. The powder sample was characterized by thermoluminescence (TL) glow curve analysis. In TL glow curve the optimized concentration in 1mol% for UV irradiated sample. The kinetic parameters were calculated by computerized glow curve deconvolution (CGCD) techniaue. Trapping parameters gives the information of dosimetry loss in prepared phosphor and its usability in environmental monitoring and for personal monitoring. CGCD is the advance tool for analysis of complicated TL glow curves.
Gaining competitive advantage in personal dosimetry services through ISO 9001 certification.
Noriah, M A
2007-01-01
This paper discusses the advantage of certification process in the quality assurance of individual dose monitoring in Malaysia. The demand by customers and the regulatory authority for a higher degree of quality service requires a switch in emphasis from a technically focused quality assurance program to a comprehensive quality management for service provision. Achieving the ISO 9001:2000 certification by an accredited third party demonstrates acceptable recognition and documents the fact that the methods used are capable of generating results that satisfy the performance criteria of the certification program. It also offers a proof of the commitment to quality and, as a benchmark, allows measurement of the progress for continual improvement of service performance.
A national UK survey of radiology trainees special interest choices: what and why?
Parvizi, Nassim; Bhuva, Shaheel
2017-11-01
A national survey was designed to better understand factors influencing special interest choices, future aspirations of UK radiology trainees and perceptions of breast radiology. A SurveyMonkey questionnaire was developed and distributed to all radiology trainees in the UK through the British Institute of Radiology, RCR Junior Radiologists Forum and by directly contacting UK training schemes as well as by social media between December 2015 and January 2016. From 21 training schemes across the UK, 232 responses were received. Over half entered radiology after foundation training and 62% were ST1-3; one-fifth of trainees intended to leave the NHS. The most popular special interests were musculoskeletal (18%), abdominal imaging (16%) and neuroradiology (13%). Gynaecological and oncological imaging proved to be the least popular. Strong personal interest, a successful rotation during training, a mix of imaging modalities, direct impact on patient care and job prospects were the most popular factors influencing career choice. Research and potential for private income were the least influential factors. Respondents detailed their perceptions of breast radiology, selecting an awareness of career prospects (41%) and a better trainee experience (36%) as factors that would increase their interest in pursuing it as a career. Understanding the factors that influence special interest choice is essential to addressing the alarming staffing shortfalls that will befall certain radiology special interests. Addressing trainee's preconceptions and improving the trainee experience are key to attracting trainees to breast radiology. Advances in knowledge: This is the first survey of its kind in the UK literature designed to evaluate special interest career choices and the factors that influence those among radiology trainees.
Reactor Dosimetry State of the Art 2008
NASA Astrophysics Data System (ADS)
Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan
2009-08-01
Oral session 1: Retrospective dosimetry. Retrospective dosimetry of VVER 440 reactor pressure vessel at the 3rd unit of Dukovany NPP / M. Marek ... [et al.]. Retrospective dosimetry study at the RPV of NPP Greifswald unit 1 / J. Konheiser ... [et al.]. Test of prototype detector for retrospective neutron dosimetry of reactor internals and vessel / K. Hayashi ... [et al.]. Neutron doses to the concrete vessel and tendons of a magnox reactor using retrospective dosimetry / D. A. Allen ... [et al.]. A retrospective dosimetry feasibility study for Atucha I / J. Wagemans ... [et al.]. Retrospective reactor dosimetry with zirconium alloy samples in a PWR / L. R. Greenwood and J. P. Foster -- Oral session 2: Experimental techniques. Characterizing the Time-dependent components of reactor n/y environments / P. J. Griffin, S. M. Luker and A. J. Suo-Anttila. Measurements of the recoil-ion response of silicon carbide detectors to fast neutrons / F. H. Ruddy, J. G. Seidel and F. Franceschini. Measurement of the neutron spectrum of the HB-4 cold source at the high flux isotope reactor at Oak Ridge National Laboratory / J. L. Robertson and E. B. Iverson. Feasibility of cavity ring-down laser spectroscopy for dose rate monitoring on nuclear reactor / H. Tomita ... [et al.]. Measuring transistor damage factors in a non-stable defect environment / D. B. King ... [et al.]. Neutron-detection based monitoring of void effects in boiling water reactors / J. Loberg ... [et al.] -- Poster session 1: Power reactor surveillance, retrospective dosimetry, benchmarks and inter-comparisons, adjustment methods, experimental techniques, transport calculations. Improved diagnostics for analysis of a reactor pulse radiation environment / S. M. Luker ... [et al.]. Simulation of the response of silicon carbide fast neutron detectors / F. Franceschini, F. H. Ruddy and B. Petrović. NSV A-3: a computer code for least-squares adjustment of neutron spectra and measured dosimeter responses / J. G. Williams, A. P. Ribaric and T. Schnauber. Agile high-fidelity MCNP model development techniques for rapid mechanical design iteration / J. A. Kulesza.Extension of Raptor-M3G to r-8-z geometry for use in reactor dosimetry applications / M. A. Hunter, G. Longoni and S. L. Anderson. In vessel exposure distributions evaluated with MCNP5 for Atucha II / J. M. Longhino, H. Blaumann and G. Zamonsky. Atucha I nuclear power plant azimutal ex-vessel flux profile evaluation / J. M. Longhino ... [et al.]. UFTR thermal column characterization and redesign for maximized thermal flux / C. Polit and A. Haghighat. Activation counter using liquid light-guide for dosimetry of neutron burst / M. Hayashi ... [et al.]. Control rod reactivity curves for the annular core research reactor / K. R. DePriest ... [et al.]. Specification of irradiation conditions in VVER-440 surveillance positions / V. Kochkin ... [et al.]. Simulations of Mg-Ar ionisation and TE-TE ionisation chambers with MCNPX in a straightforward gamma and beta irradiation field / S. Nievaart ... [et al.]. The change of austenitic stainless steel elements content in the inner parts of VVER-440 reactor during operation / V. Smutný, J. Hep and P. Novosad. Fast neutron environmental spectrometry using disk activation / G. Lövestam ... [et al.]. Optimization of the neutron activation detector location scheme for VVER-lOOO ex-vessel dosimetry / V. N. Bukanov ... [et al.]. Irradiation conditions for surveillance specimens located into plane containers installed in the WWER-lOOO reactor of unit 2 of the South-Ukrainian NPP / O. V. Grytsenko. V. N. Bukanov and S. M. Pugach. Conformity between LRO mock-ups and VVERS NPP RPV neutron flux attenuation / S. Belousov. Kr. Ilieva and D. Kirilova. FLUOLE: a new relevant experiment for PWR pressure vessel surveillance / D. Beretz ... [et al.]. Transport of neutrons and photons through the iron and water layers / M. J. Kost'ál ... [et al.]. Condition evaluation of spent nuclear fuel assemblies from the first-generation nuclear-powered submarines by gamma scanning / A. F. Usatyi. L. A. Serdyukova and B. S. Stepennov -- Oral session 3: Power plant surveillance. Upgraded neutron dosimetry procedure for VVER-440 surveillance specimens / V. Kochkin ... [et al.]. Neutron dosimetry on the full-core first generation VVER-440 aimed to reactor support structure load evaluation / P. Borodkin ... [et al.]. Ex-vessel neutron dosimetry programs for PWRs in Korea / C. S. Yoo. B. C. Kim and C. C. Kim. Comparison of irradiation conditions of VVER-1000 reactor pressure vessel and surveillance specimens for various core loadings / V. N. Bukanov ... [et al.]. Re-evaluation of dosimetry in the new surveillance program for the Loviisa 1 VVER-440 reactor / T. Serén -- Oral session 4: Benchmarks, intercomparisons and adjustment methods. Determination of the neutron parameter's uncertainties using the stochastic methods of uncertainty propagation and analysis / G. Grégoire ... [et al.].Covariance matrices for calculated neutron spectra and measured dosimeter responses / J. G. Williams ... [et al.]. The role of dosimetry at the high flux reactor / S. C. van der Marek ... [et al.]. Calibration of a manganese bath relative to Cf-252 nu-bar / D. M. Gilliam, A. T. Yue and M. Scott Dewey. Major upgrade of the reactor dosimetry interpretation methodology used at the CEA: general principle / C. Destouches ... [et al.] -- Oral session 5: power plant surveillance. The role of ex-vessel neutron dosimetry in reactor vessel surveillance in South Korea / B.-C. Kim ... [et al.]. Spanish RPV surveillance programmes: lessons learned and current activities / A. Ballesteros and X. Jardí. Atucha I nuclear power plant extended dosimetry and assessment / H. Blaumann ... [et al.]. Monitoring of radiation load of pressure vessels of Russian VVER in compliance with license amendments / G. Borodkin ... [et al.] -- Poster session 2: Test reactors, accelerators and advanced systems; cross sections, nuclear data, damage correlations. Two-dimensional mapping of the calculated fission power for the full-size fuel plate experiment irradiated in the advanced test reactor / G. S. Chang and M. A. Lillo. The radiation safety information computational center: a resource for reactor dosimetry software and nuclear data / B. L. Kirk. Irradiated xenon isotopic ratio measurement for failed fuel detection and location in fast reactor / C. Ito, T. Iguchi and H. Harano. Characterization of dosimetry of the BMRR horizontal thimble tubes and broad beam facility / J.-P. Hu, R. N. Reciniello and N. E. Holden. 2007 nuclear data review / N. E. Holden. Further dosimetry studies at the Rhode Island nuclear science / R. N. Reciniello ... [et al.]. Characterization of neutron fields in the experimental fast reactor Joyo MK-III core / S. Maeda ... [et al.]. Measuring [symbol]Li(n, t) and [symbol]B(n, [symbol]) cross sections using the NIST alpha-gamma apparatus / M. S. Dewey ... [et al.]. Improvement of neutron/gamma field evaluation for restart of JMTR / Y. Nagao ... [et al.]. Monitoring of the irradiated neutron fluence in the neutron transmutation doping process of HANARO / M.-S. Kim and S.-J. Park.Training reactor VR-l neutron spectrum determination / M. Vins, A. Kolros and K. Katovsky. Differential cross sections for gamma-ray production by 14 MeV neutrons on iron and bismuth / V. M. Bondar ... [et al.]. The measurements of the differential elastic neutron cross-sections of carbon for energies from 2 to 133 ke V / O. Gritzay ... [et al.]. Determination of neutron spectrum by the dosimetry foil method up to 35 Me V / S. P. Simakov ... [et al.]. Extension of the BGL broad group cross section library / D. Kirilova, S. Belousov and Kr. Ilieva. Measurements of neutron capture cross-section for tantalum at the neutron filtered beams / O. Gritzayand V. Libman. Measurements of microscopic data at GELINA in support of dosimetry / S. Kopecky ... [et al.]. Nuclide guide and international chart of nuclides - 2008 / T. Golashvili -- Oral session 6: Test reactors, accelerators and advanced systems. Neutronic analyses in support of the HFIR beamline modifications and lifetime extension / I. Remec and E. D. Blakeman. Characterization of neutron test facilities at Sandia National Laboratories / D. W. Vehar ... [et al.]. LYRA irradiation experiments: neutron metrology and dosimetry / B. Acosta and L. Debarberis. Calculated neutron and gamma-ray spectra across the prismatic very high temperature reactor core / J. W. Sterbentz. Enhancement of irradiation capability of the experimental fast reactor joyo / S. Maeda ... [et al.]. Neutron spectrum analyses by foil activation method for high-energy proton beams / C. H. Pyeon ... [et al.] -- Oral session 7: Cross sections, nuclear data, damage correlations. Investigation of new reaction cross-section evaluations in order to update and extend the IRDF-2002 reactor dosimetry library / É. M. Zsolnay, H. J. Nolthenius and A. L. Nichols. A novel approach towards DPA calculations / A. Hogenbirk and D. F. Da Cruz. A new ENDFIB-VII.O based multigroup cross-section library for reactor dosimetry / F. A. Alpan and S. L. Anderson. Activities at the NEA for dosimetry applications / H. Henriksson and I. Kodeli. Validation and verification of covariance data from dosimetry reaction cross-section evaluations / S. Badikov. Status of the neutron cross section standards / A. D. Carlson -- Oral session 8: transport calculations. A dosimetry assessment for the core restraint of an advanced gas cooled reactor / D. A. Thornton ... [et al.]. Neutron dosimetry study in the region of the support structure of a VVER-1000 type reactor / G. Borodkin ... [et al.]. SNS moderator poison design and experiment validation of the moderator performance / W. Lu ... [et al.]. Analysis of OSIRIS in-core surveillance dosimetry for GONDOLE steel irradiation program by using TRIPOLI-4 Monte Carlo code / Y. K. Lee and F. Malouch.Reactor dosimetry applications using RAPTOR-M3G: a new parallel 3-D radiation transport code / G. Longoni and S. L. Anderson.
Teaching and Learning French--A Tale of Desire in the Humanities
ERIC Educational Resources Information Center
Cunningham, Catriona
2017-01-01
This article considers the way we talk about learning and teaching the humanities in higher education in the UK. By using the tools of the arts and humanities within the scholarship of learning and teaching, and examining a personal perspective, the author explores the transformational impact of French language learning and teaching. Close textual…
Assessment of Prevalence of Persons with Down Syndrome: A Theory-Based Demographic Model
ERIC Educational Resources Information Center
de Graaf, Gert; Vis, Jeroen C.; Haveman, Meindert; van Hove, Geert; de Graaf, Erik A. B.; Tijssen, Jan G. P.; Mulder, Barbara J. M.
2011-01-01
Background: The Netherlands are lacking reliable empirical data in relation to the development of birth and population prevalence of Down syndrome. For the UK and Ireland there are more historical empirical data available. A theory-based model is developed for predicting Down syndrome prevalence in the Netherlands from the 1950s onwards. It is…
ERIC Educational Resources Information Center
Lawrence, Anna; Turnhout, Esther
2010-01-01
The demand for biodiversity data is increasing. Governments require standardised, objective data to underpin planning and conservation decisions. These data are produced by large numbers of (volunteer) natural historians and non-governmental organisations. This article analyses the interface between the state and the volunteer naturalists to…
Fairtrade in Schools: Teaching Ethics or Unlawful Marketing to the Defenceless?
ERIC Educational Resources Information Center
Griffiths, Peter
2014-01-01
Schools in the UK teach pupils about Fairtrade as part of Religious Education, Personal and Social Education, Citizenship, Geography and so on. There are also Fairtrade Schools, where the whole school, including staff and parents, is committed to promoting the brand. It is argued here that promoting this commercial brand to schoolchildren and…
ERIC Educational Resources Information Center
Scott, G. W.; Furnell, J.; Murphy, C. M.; Goulder, R.
2015-01-01
Biology teachers in a UK university expressed a majority view that student learning autonomy increases with progression through university. A minority suggested that pre-existing diversity in learning autonomy was more important and that individuals not cohorts differ in their learning autonomy. They suggested that personal experience prior to…
Hunt the Shadow Not the Substance: The Rise of the Career Academic in Construction Education
ERIC Educational Resources Information Center
Tennant, Stuart; Murray, Mike; Forster, Alan; Pilcher, Nick
2015-01-01
Construction education is context-laden, navigating and reflecting the byzantine influences of period, place and person. Despite considerable rhetoric, in UK higher education and construction studies in particular the importance of contextualized teaching is being devalued. Over the past decade a growing number of new teaching staff to university…
Statistical Models for Linguistic Variation in Online Media
ERIC Educational Resources Information Center
Kulkarni, Vivek
2017-01-01
Language on the Internet and social media varies due to time, geography, and social factors. For example, consider an online chat forum where people from different regions across the world interact. In such scenarios, it is important to track and detect regional variation in language. A person from the UK, who is in conversation with someone from…
ERIC Educational Resources Information Center
Frimberger, Katja
2016-01-01
This article explores the author's embodied experience of linguistic incompetence in the context of an interview-based, short, promotional film production about people's personal connections to their spoken languages in Glasgow, Scotland/UK. The article highlights that people's right to their spoken languages during film interviews and the…
ERIC Educational Resources Information Center
Chalmers, Helen; Tyrer, Paul; Aggleton, Peter
2006-01-01
Objective: In support of the UK Government's teenage pregnancy and sexual health strategies, a certificated programme of professional development for school nurses and other community nurses was developed to provide support for personal, social and health education (PSHE) work, including sex and relationships education (SRE), for young people.…
Locating the "I" in the Teaching of Death and Dying: Challenges of the Open Distance Learning Model
ERIC Educational Resources Information Center
Watts, Jacqueline H.
2007-01-01
The UK Open University's second-level undergraduate course "Death and Dying" (K260) draws on personal and professional experience to explore the issues of loss, care, ethical practice, communication and grief. Students come from diverse occupational backgrounds (nurses, social workers, medical practitioners) but many study K260 for…
A Progress Report on Progress Files. The Experience of One Higher Education Institution
ERIC Educational Resources Information Center
East, Rob
2005-01-01
In order to facilitate personal development planning (PDP), the UK higher education sector is committed to introducing progress files. This article explores the experience of one institution in seeking to establish a system of progress files. It identifies the main practical problems in doing this, highlighting the lack of agreement on the skills…
Developing Survey Measures of Inequality of Autonomy in the UK
ERIC Educational Resources Information Center
Burchardt, Tania; Holder, Holly
2012-01-01
This paper explores the development of survey questions to measure autonomy, interpreted as the degree of choice and control a person has in key areas of his or her life. A review of the theoretical literature leads to a conceptualisation of autonomy as consisting of three components: (1) self-reflection, (2) active or delegated decision-making,…
Making an "Impact": Some Personal Reflections on the Humanities in the UK
ERIC Educational Resources Information Center
Looseley, David
2011-01-01
This article brings together reflections on the impact agenda from two separate sources: a conference at the University of Warwick in August 2009, and a speech given at the University of Leeds some weeks before. It develops these reflections with particular reference to Modern Languages, reviewing how the Humanities probe other value systems, deal…
Children's Socialisation into Schools' Learning Contexts: Ability Grouping in the UK Primary School.
ERIC Educational Resources Information Center
Hallam, Susan; Ireson, Judith; Mortimore, Peter; Davies, Jane
As the incidence of ability grouping at the primary level increases in the United Kingdom, questions remain regarding the effect of various grouping arrangements on students' personal and social development and the role of the school ethos in adopting particular ability grouping structures. This research explored the rationale given by primary…
ERIC Educational Resources Information Center
Wang, Isobel Kai-Hui
2018-01-01
The global population of students pursuing studies abroad continues to grow, and consequently their intercultural experiences are receiving greater research attention. However, research into long-term student sojourners' academic development and personal growth is still in its infancy. A parallel mixed method study was designed to investigate the…
Schaeken, B; Cuypers, R; Lelie, S; Schroeyers, W; Schreurs, S; Janssens, H; Verellen, D
2011-04-01
A measurement procedure based on alanine/electron paramagnetic resonance (EPR) dosimetry was implemented successfully providing simple, stable, and accurate dose-to-water (D(w)) measurements. The correspondence between alanine and ionization chamber measurements in reference conditions was excellent. Alanine/EMR dosimetry might be a valuable alternative to thermoluminescent (TLD) and ionization chamber based measuring procedures in radiotherapy audits. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Safety: Radiation Protection Manual
1997-05-30
t e c h n i c a l publication requires it, (2) personnel are required to wear dosimetry , EM 385-1-80 30 May 97 2-4 (3) personnel are required to...of SOPs, review of dosimetry results, changes in standards or guidance, equipment changes, and any other pertinent radiation safety information that...Table 3-4. The EDE is used in dosimetry to account for different organs having different sensitivities to radiation. Table 3-4 Weighting Factors
Publicly Released Prompt Radiation Spectra Suitable for Nuclear Detonation Simulations, Revision 1
2017-12-01
dominates the photon emission. During the Hiroshima and Nagasaki bombings , the prompt radiation contributed from 40% to 70% of the free-in-air dose...Terms for the Initial Radiation. LA-UR-83-198. US-Japan Joint Workshop on the Reassessment of the A- Bomb Radiation Dosimetry in Hiroshima and Nagasaki...2005). Reassessment of the Atomic Bomb Radiation Dosimetry for Hiroshima and Nagasaki—Dosimetry System 2002. Hiroshima, Japan: Radiation Effects
1989-12-15
conditions of these experiments. In order to provide reliable quantitative data on exposure, a system with automated dosimetry was developed, and tested...exposure system and dosimetry, and (2) studies on lymphocyte cultures, and (3) conclusions. EXPOSURE SYSTEM AND DOSIMETRY Description of the Exposure... System The experiments planned in this project necessitated the design and assembly of an exposure system that would meet several engineering
Megias, Daniel; Phillips, Mark; Clifton-Hadley, Laura; Harron, Elizabeth; Eaton, David J; Sanghera, Paul; Whitfield, Gillian
2017-03-01
The HIPPO trial is a UK randomized Phase II trial of hippocampal sparing (HS) vs conventional whole-brain radiotherapy after surgical resection or radiosurgery in patients with favourable prognosis with 1-4 brain metastases. Each participating centre completed a planning benchmark case as part of the dedicated radiotherapy trials quality assurance programme (RTQA), promoting the safe and effective delivery of HS intensity-modulated radiotherapy (IMRT) in a multicentre trial setting. Submitted planning benchmark cases were reviewed using visualization for radiotherapy software (VODCA) evaluating plan quality and compliance in relation to the HIPPO radiotherapy planning and delivery guidelines. Comparison of the planning benchmark data highlighted a plan specified using dose to medium as an outlier by comparison with those specified using dose to water. Further evaluation identified that the reported plan statistics for dose to medium were lower as a result of the dose calculated at regions of PTV inclusive of bony cranium being lower relative to brain. Specification of dose to water or medium remains a source of potential ambiguity and it is essential that as part of a multicentre trial, consideration is given to reported differences, particularly in the presence of bone. Evaluation of planning benchmark data as part of an RTQA programme has highlighted an important feature of HS IMRT dosimetry dependent on dose being specified to water or medium, informing the development and undertaking of HS IMRT as part of the HIPPO trial. Advances in knowledge: The potential clinical impact of differences between dose to medium and dose to water are demonstrated for the first time, in the setting of HS whole-brain radiotherapy.
Which terms should be used to describe autism? Perspectives from the UK autism community.
Kenny, Lorcan; Hattersley, Caroline; Molins, Bonnie; Buckley, Carole; Povey, Carol; Pellicano, Elizabeth
2016-05-01
Recent public discussions suggest that there is much disagreement about the way autism is and should be described. This study sought to elicit the views and preferences of UK autism community members - autistic people, parents and their broader support network - about the terms they use to describe autism. In all, 3470 UK residents responded to an online survey on their preferred ways of describing autism and their rationale for such preferences. The results clearly show that people use many terms to describe autism. The most highly endorsed terms were 'autism' and 'on the autism spectrum', and to a lesser extent, 'autism spectrum disorder', for which there was consensus across community groups. The groups disagreed, however, on the use of several terms. The term 'autistic' was endorsed by a large percentage of autistic adults, family members/friends and parents but by considerably fewer professionals; 'person with autism' was endorsed by almost half of professionals but by fewer autistic adults and parents. Qualitative analysis of an open-ended question revealed the reasons underlying respondents' preferences. These findings demonstrate that there is no single way of describing autism that is universally accepted and preferred by the UK's autism community and that some disagreements appear deeply entrenched. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holliday, B.
Attention is drawn to the lack of information available concerning the standards of radiation protection during dental radiography in the UK. Brief summaries are presented of three cases illustrating the type of hazards that might arise from faulty x-ray equipment or bad operating techniques. It is pointed out that the NRPB service to dentists offers a survey procedure designed to reduce or eleminate radiation exposures of patients. Data concerning beam size, quality, and duration of the x-ray exposure is obtained from a combined film and filted pack sent to the dentist, and this information is supplemented by a questionnaire. Themore » results are assessed with reference to the Code of Practice for the Protection of Persons against Ionizing Radiations arising from Medical and Dental Use. (UK)« less
SU-F-T-562: Validation of EPID-Based Dosimetry for FSRS Commissioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Y; Saleh, Z; Obcemea, C
Purpose: The prevailing approach to frameless SRS (fSRS) small field dosimetry is Gafchromic film. Though providing continuous information, its intrinsic uncertainties in fabrication, response, scan, and calibration often make film dosimetry subject to different interpretations. In this study, we explored the feasibility of using EPID portal dosimetry as a viable alternative to film for small field dosimetry. Methods: Plans prescribed a dose of 21 Gy were created on a flat solid water phantom with Eclipse V11 and iPlan for small static square fields (1.0 to 3.0 cm). In addition, two clinical test plans were computed by employing iPlan on amore » CIRS Kesler head phantom for target dimensions of 1.2cm and 2.0cm. Corresponding portal dosimetry plans were computed using the Eclipse TPS and delivered on a Varian TrueBeam machine. EBT-XD film dosimetry was performed as a reference. The isocenter doses were measured using EPID, OSLD, stereotactic diode, and CC01 ion chamber. Results: EPID doses at the center of the square field were higher than Eclipse TPS predicted portal doses, with the mean difference being 2.42±0.65%. Doses measured by EBT-XD film, OSLD, stereotactic diode, and CC01 ion chamber revealed smaller differences (except OSLDs), with mean differences being 0.36±3.11%, 4.12±4.13%, 1.7±2.76%, 1.45±2.37% for Eclipse and −1.36±0.85%, 2.38±4.2%, −0.03±0.50%, −0.27±0.78% for iPlan. The profiles measured by EPID and EBT-XD film resembled TPS (Eclipse and iPlan) predicted ones within 3.0%. For the two clinical test plans, the EPID mean doses at the center of field were 2.66±0.68% and 2.33±0.32% higher than TPS predicted doses. Conclusion: We found that results obtained with EPID portal dosimetry were slightly higher (∼2%) than those obtained with EBT-XD film, diode, and CC01 ion chamber with the exception of OSLDs, but well within IROC tolerance (5.0%). Therefore, EPID has the potential to become a viable real-time alternative method to film dosimetry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsunaga, T; Adachi, Y; Hayashi, N
Purpose: Japan Standard Dosimetry of Absorbed dose to water in external beam radiotherapy (JSDP12) is widely used to measure radiation dose in radiotherapy. However, JSDP12 does not take flattening-filter-free (FFF) beam into consideration. In addition, JSDP12 applied TPR20,10 for dose quality index for photon beam. The purpose of this study is to compare JSDP12 with AAPM TG-51 addendum in order to establish optimal dosimetry procedure for FFF beam. Method: We evaluated the ion-recombination factor (ks) and the correction factor of radial beam profile (Prp) in FFF beam dosimetry. The ks was introduced by 2 voltages method and verified by Jaffe’smore » plot. The Prp was given by both film measurement and calculation of treatment planning system, and compared them. Next, we compared the dose quality indexes (kQ) between TPR20,10 method and PDD(10)x method. Finally we considered optimal dosimetry protocol for FFF photon beam using JSDP12 with referring TG-51 addendum protocols. The FFF photon beams of 6 MV (6X-FFF) and 10 MV (10X-FFF) from TrueBeam were investigated in this study. Results: The ks for 6X-FFF and 10X-FFF beams were 1.005 and 1.010, respectively. The Prp of 0.6 cc ionization chamber for 6X-FFF and 10X-FFF beams (Film, TPS) were (1.004, 1.008) and (1.005, 1.008), respectively. The kQ for 6X-FFF and 10X-FFF beams (JSDP12, TG-51 addendum) were (0.9950, 0.9947) and (0.9851, 0.9845), respectively. The most effective factor for uncertainty in FFF photon beam measurement was Prp for JSDP12 formalism. Total dosimetric differences between JSDP12 and TG-51 addendum for 6X-FFF and 10X-FFF were -0.47% and -0.73%, respectively. Conclusion: The total dosimetric difference between JSDP12 and TG-51 addendum was within 1%. The introduction of kQ given by JSDP is feasible for FFF photon beam dosimetry. However, we think Prp should be considered for optimal dosimetry procedure even if JSDP12 is used for FFF photon beam dosimetry.« less
NASA Astrophysics Data System (ADS)
Pogue, Brian W.; Elliott, Jonathan T.; Kanick, Stephen C.; Davis, Scott C.; Samkoe, Kimberley S.; Maytin, Edward V.; Pereira, Stephen P.; Hasan, Tayyaba
2016-04-01
Photodynamic therapy (PDT) can be a highly complex treatment, with many parameters influencing treatment efficacy. The extent to which dosimetry is used to monitor and standardize treatment delivery varies widely, ranging from measurement of a single surrogate marker to comprehensive approaches that aim to measure or estimate as many relevant parameters as possible. Today, most clinical PDT treatments are still administered with little more than application of a prescribed drug dose and timed light delivery, and thus the role of patient-specific dosimetry has not reached widespread clinical adoption. This disconnect is at least partly due to the inherent conflict between the need to measure and understand multiple parameters in vivo in order to optimize treatment, and the need for expedience in the clinic and in the regulatory and commercialization process. Thus, a methodical approach to selecting primary dosimetry metrics is required at each stage of translation of a treatment procedure, moving from complex measurements to understand PDT mechanisms in pre-clinical and early phase I trials, towards the identification and application of essential dose-limiting and/or surrogate measurements in phase II/III trials. If successful, identifying the essential and/or reliable surrogate dosimetry measurements should help facilitate increased adoption of clinical PDT. In this paper, examples of essential dosimetry points and surrogate dosimetry tools that may be implemented in phase II/III trials are discussed. For example, the treatment efficacy as limited by light penetration in interstitial PDT may be predicted by the amount of contrast uptake in CT, and so this could be utilized as a surrogate dosimetry measurement to prescribe light doses based upon pre-treatment contrast. Success of clinical ALA-based skin lesion treatment is predicted almost uniquely by the explicit or implicit measurements of photosensitizer and photobleaching, yet the individualization of treatment based upon each patients measured bleaching needs to be attempted. In the case of ALA, lack of PpIX is more likely an indicator that alternative PpIX production methods must be implemented. Parsimonious dosimetry, using surrogate measurements that are clinically acceptable, might strategically help to advance PDT in a medical world that is increasingly cost and time sensitive. Careful attention to methodologies that can identify and advance the most critical dosimetric measurements, either direct or surrogate, are needed to ensure successful incorporation of PDT into niche clinical procedures.
NASA Astrophysics Data System (ADS)
Ahmed, Md Foiez
Scope and Method of Study: The goal of this work was to develop and demonstrate a 2D dosimetry system based on the optically stimulated luminescence (OSL) from new Al2O3 films for radiotherapy applications. A 2D laser-scanning system was developed for the readout and two OSL films (Al2O3:C and Al2O3:C,Mg) were tested. A dose reconstruction algorithm addressing corrections required for the characteristic material properties and the properties related to the system design was developed. The dosimetric properties of the system were tested using clinical X-ray (6 MV) beam. The feasibility of small field dosimetry was tested using heavy ion beams (221 MeV proton and 430 MeV 12C beam). For comparison, clinical tests were performed with ionization chamber, diode arrays and the commercial radiochromic films (Gafchromic EBT3) when applicable. Findings and Conclusions: The results demonstrate that the developed image reconstruction algorithm enabled > 300x faster laser-scanning readout of the Al2O3 films, eliminating the restriction imposed by its slow luminescence decay. The algorithm facilitates submillimeter spatial resolution, reduces the scanner position dependence (of light collection efficiency) and removes the inherent galvo geometric distortion, among other corrections. The system has a background signal < 1 mGy, linearity correction factor of < 10% up to ˜4.0 Gy and < 2% dose uncertainty over the clinically relevant dose range of 0.1 - 30 Gy. The system has a dynamic range of 4 - 5 orders, only limited by PMT linearity. The absolute response from Al2O2:C films is higher than Al2O 2:C,Mg films, but with lower image signal-to-noise ratio due to lower concentration of fast F+-center emission. As a result, Al2O2:C,Mg films are better suited than Al2O3:C films for small field dosimetry, which requires precise dosimetry with sub-millimeter spatial resolution. The dose uncertainty associated with OSL film dosimetry is lower than that associated with EBT3 film dosimetry due to lower background, simpler calibration and wider dynamic range. In conclusion, this work demonstrates excellent potentials of the 2D OSL dosimetry system for both relative and absolute dosimetry in radiotherapy applications, with especial emphasis on small fields.
NASA Astrophysics Data System (ADS)
Besemer, Abigail E.
Targeted radionuclide therapy is emerging as an attractive treatment option for a broad spectrum of tumor types because it has the potential to simultaneously eradicate both the primary tumor site as well as the metastatic disease throughout the body. Patient-specific absorbed dose calculations for radionuclide therapies are important for reducing the risk of normal tissue complications and optimizing tumor response. However, the only FDA approved software for internal dosimetry calculates doses based on the MIRD methodology which estimates mean organ doses using activity-to-dose scaling factors tabulated from standard phantom geometries. Despite the improved dosimetric accuracy afforded by direct Monte Carlo dosimetry methods these methods are not widely used in routine clinical practice because of the complexity of implementation, lack of relevant standard protocols, and longer dose calculation times. The main goal of this work was to develop a Monte Carlo internal dosimetry platform in order to (1) calculate patient-specific voxelized dose distributions in a clinically feasible time frame, (2) examine and quantify the dosimetric impact of various parameters and methodologies used in 3D internal dosimetry methods, and (3) develop a multi-criteria treatment planning optimization framework for multi-radiopharmaceutical combination therapies. This platform utilizes serial PET/CT or SPECT/CT images to calculate voxelized 3D internal dose distributions with the Monte Carlo code Geant4. Dosimetry can be computed for any diagnostic or therapeutic radiopharmaceutical and for both pre-clinical and clinical applications. In this work, the platform's dosimetry calculations were successfully validated against previously published reference doses values calculated in standard phantoms for a variety of radionuclides, over a wide range of photon and electron energies, and for many different organs and tumor sizes. Retrospective dosimetry was also calculated for various pre-clinical and clinical patients and large dosimetric differences resulted when using conventional organ-level methods and the patient-specific voxelized methods described in this work. The dosimetric impact of various steps in the 3D voxelized dosimetry process were evaluated including quantitative imaging acquisition, image coregistration, voxel resampling, ROI contouring, CT-based material segmentation, and pharmacokinetic fitting. Finally, a multi-objective treatment planning optimization framework was developed for multi-radiopharmaceutical combination therapies.
The Borderline Syndrome Index: a validation study using the personality assessment schedule.
Marlowe, M J; O'Neill-Byrne, K; Lowe-Ponsford, F; Watson, J P
1996-01-01
This study examines the validity and screening properties of the Borderline Syndrome Index--BSI (developed in the USA) for categories of the Personality Assessment Schedule--PAS (developed in the UK). Patients were recruited by case control sampling. Chance corrected agreement between instruments and screening properties of the BSI were calculated. The BSI proved a moderately sensitive but non-specific screen. Questionnaire scores were highly correlated with symptom measures. The results do not support the validity of the BSI or its use as a screening instrument. BSI scores may be distorted by current symptoms.
Deep nursing: a thoughtful, co-created nursing process.
Griffiths, Colin
2017-03-30
This article examines some of the challenges in nursing practice experienced by patients and nurses in the UK and Ireland, and considers some of the associated stressors in the system. Nurses must respond to these challenges by crafting their own practice, and the article offers a blueprint for developing personal nursing practice through acceptance, paying detailed attention to patients, taking time with patients and personal reflection. It draws on innovations in learning disability practice to suggest that care should be jointly thought through and co-created by patients and nurses, and that this process of thoughtful engagement constitutes 'deep nursing'.
Constipation: causes and cures.
Christer, Ruth; Robinson, Liz; Bird, Clare
Constipation is a common but poorly understood problem. Within the UK it is estimated that three million GP consultations relate to constipation every year. It is a problem that could affect any person at any time, yet it is often preventable. There is no accepted definition for constipation, however, and it is open to individual interpretation. Some may describe constipation as passing hard stools, others may describe it as infrequent defaecation. Constipation can affect a person's physical, psychological and social wellbeing. Nurses are in a key position to help with this problem, although a multidisciplinary approach is needed if treatment is to be successful.
Zadeh, S; Foster, J
2016-01-01
The use of sperm donation by single women has provoked public, professional and political debate. Newspapers serve as a critical means of both broadcasting this debate and effecting a representation of this user group within the public sphere. This study uses the theory of social representations to examine how single motherhood by sperm donation has been represented in the UK news over time. The study sampled news coverage on this topic in eight British newspapers during three 4-year periods between the years 1988 and 2012. The dataset of news reports ( n = 406) was analysed using a qualitative approach. Findings indicated that UK media reports of single women using donor sperm are underpinned by conventional categories of the 'personal', the 'traditional' and the 'natural' that when paired with their corollaries produce a representation of this user group as the social 'other'. The amount of coverage on this topic over time was found to vary according to the political orientation of different media sources. Using key concepts from social representations theory, this article discusses the relationship between themata and anchoring in the maintenance of representations of the social 'other' in mass mediated communication. Findings are explained in relation to theoretical conceptions of the mass media and its position within the public sphere. It is argued that the use of personal narratives in news reports of single mothers by sperm donation may have significant implications for public understandings of this social group. © 2016 The Authors. Journal of Community & Applied Social Psychology published by John Wiley & Sons Ltd.