Sample records for uks sentinel drainage

  1. In transit sentinel node drainage as a prognostic factor for patients with cutaneous melanoma.

    PubMed

    Brandão, Paulo H D M; Bertolli, Eduardo; Doria-Filho, Eduardo; Santos Filho, Ivan D A O; de Macedo, Mariana P; Pinto, Clovis A L; Duprat Neto, João P

    2018-02-26

    Minor basin or in transit node drainage can be found in patients with cutaneous melanoma who undergo sentinel node biopsy. Its clinical impact is still unclear. Our objective is to evaluate clinical outcomes in patients who presented with in transit sentinel node (ITN) drainage. Retrospective analysis of patients who underwent sentinel node biopsy (SNB) in a single Brazilian institution between 2000 and 2015. Our cohort comprised 1223 SNB. There were 64 patients (5.2%) with ITN. Melanoma of the limbs (OR 10.61, P < 0.0001) and acral subtype (OR 3.49, P < 0.0001) were associated with ITN drainage. Among these 64 patients, 14 (21.9%) had a positive SNB. The ITN was positive for metastases in five patients, four in a popliteal basin and one on the trunk. Regarding completion node dissection (CND), two patients had positive non-sentinel nodes (NSN), both in major basins. In patients who developed recurrence, time to recurrence was shorter (mean time 18 vs 31.4 months, P = 0.001) and time to death was shorter (mean time 31.6 vs 40 months, P = 0.039) in those who had ITN drainage. ITN drainage was associated with earlier recurrences and deaths from melanoma. © 2018 Wiley Periodicals, Inc.

  2. Lymphatic Drainage from Renal Tumors In Vivo: A Prospective Sentinel Node Study Using SPECT/CT Imaging.

    PubMed

    Kuusk, Teele; De Bruijn, Roderick; Brouwer, Oscar R; De Jong, Jeroen; Donswijk, Maarten; Grivas, Nikolaos; Hendricksen, Kees; Horenblas, Simon; Prevoo, Warner; Valdés Olmos, Renato A; Van Der Poel, Henk G; Van Rhijn, Bas W G; Wit, Esther M; Bex, Axel

    2018-06-01

    Lymphatic drainage from renal tumors is unpredictable. In vivo drainage studies of primary lymphatic landing sites may reveal the variability and dynamics of lymphatic connections. The purpose of this study was to investigate the lymphatic drainage pattern of renal tumors in vivo with single photon emission/computerized tomography after intratumor radiotracer injection. We performed a phase II, prospective, single arm study to investigate the distribution of sentinel nodes from renal tumors on single photon emission/computerized tomography. Patients with cT1-3 (less than 10 cm) cN0M0 renal tumors of any subtype were enrolled in analysis. After intratumor ultrasound guided injection of 0.4 ml 99m Tc-nanocolloid we performed preoperative imaging of sentinel nodes with lymphoscintigraphy and single photon emission/computerized tomography. Sentinel and locoregional nonsentinel nodes were resected with a γ probe combined with a mobile γ camera. The primary study end point was the location of sentinel nodes outside the locoregional retroperitoneal templates on single photon emission/computerized tomography. Using a Simon minimax 2-stage design to detect a 25% extralocoregional retroperitoneal template location of sentinel nodes on imaging at α = 0.05 and 80% power at least 40 patients with sentinel node imaging on single photon emission/computerized tomography were needed. Of the 68 patients 40 underwent preoperative single photon emission/computerized tomography of sentinel nodes and were included in primary end point analysis. Lymphatic drainage outside the locoregional retroperitoneal templates was observed in 14 patients (35%). Eight patients (20%) had supradiaphragmatic sentinel nodes. Sentinel nodes from renal tumors were mainly located in the respective locoregional retroperitoneal templates. Simultaneous sentinel nodes were located outside the suggested lymph node dissection templates, including supradiaphragmatic sentinel nodes in more than a third of the

  3. Understanding Lymphatic Drainage Pathways of the Ovaries to Predict Sites for Sentinel Nodes in Ovarian Cancer

    PubMed Central

    Kleppe, Marjolein; Kraima, Anne C.; Kruitwagen, Roy F.P.M.; Van Gorp, Toon; Smit, Noeska N.; van Munsteren, Jacoba C.; DeRuiter, Marco C.

    2015-01-01

    Objective In ovarian cancer, detection of sentinel nodes is an upcoming procedure. Perioperative determination of the patient’s sentinel node(s) might prevent a radical lymphadenectomy and associated morbidity. It is essential to understand the lymphatic drainage pathways of the ovaries, which are surprisingly up till now poorly investigated, to predict the anatomical regions where sentinel nodes can be found. We aimed to describe the lymphatic drainage pathways of the human ovaries including their compartmental fascia borders. Methods A series of 3 human female fetuses and tissues samples from 1 human cadaveric specimen were studied. Immunohistochemical analysis was performed on paraffin-embedded transverse sections (8 or 10 μm) using antibodies against Lyve-1, S100, and α-smooth muscle actin to identify the lymphatic endothelium, Schwann, and smooth muscle cells, respectively. Three-dimensional reconstructions were created. Results Two major and 1 minor lymphatic drainage pathways from the ovaries were detected. One pathway drained via the proper ligament of the ovaries (ovarian ligament) toward the lymph nodes in the obturator fossa and the internal iliac artery. Another pathway drained the ovaries via the suspensory ligament (infundibulopelvic ligament) toward the para-aortic and paracaval lymph nodes. A third minor pathway drained the ovaries via the round ligament to the inguinal lymph nodes. Lymph vessels draining the fallopian tube all followed the lymphatic drainage pathways of the ovaries. Conclusions The lymphatic drainage pathways of the ovaries invariably run via the suspensory ligament (infundibulopelvic ligament) and the proper ligament of the ovaries (ovarian ligament), as well as through the round ligament of the uterus. Because ovarian cancer might spread lymphogenously via these routes, the sentinel node can be detected in the para-aortic and paracaval regions, obturator fossa and surrounding internal iliac arteries, and inguinal regions

  4. Lymphatic drainage patterns of oral maxillary tumors: Approachable locations of sentinel lymph nodes mainly at the cervical neck level.

    PubMed

    Boeve, Koos; Schepman, Kees-Pieter; Vegt, Bert van der; Schuuring, Ed; Roodenburg, Jan L; Brouwers, Adrienne H; Witjes, Max J

    2017-03-01

    There is debate if the lymphatic drainage pattern of oral maxillary cancer is to the retropharyngeal lymph nodes or to the cervical lymph nodes. Insight in drainage patterns is important for the indication for neck treatment. The purpose of this study was to identify the lymphatic drainage pattern of oral maxillary cancer via preoperative lymphoscintigraphy. Eleven consecutive patients with oral maxillary cancer treated in our center between December 1, 2012, and April 22, 2016 were studied. Sentinel lymph nodes identified by preoperative lymphoscintigraphy after injection of 99m Tc-nanocolloid and by intraoperative detection using a γ-probe, were surgically removed and histopathologically examined. In 10 patients, sentinel lymph nodes were detected and harvested at cervical levels I, II, or III in the neck. In 2 patients, a parapharyngeal sentinel lymph node was detected. One of the harvested sentinel lymph nodes (1/19) was tumor positive. This study suggests the likelihood of 73% of exclusively cervical level I to III sentinel lymph nodes in oral maxillary cancer. © 2016 Wiley Periodicals, Inc. Head Neck 39: 486-491, 2017. © 2016 Wiley Periodicals, Inc.

  5. Constructed wetlands in UK urban surface drainage systems.

    PubMed

    Shutes, B; Ellis, J B; Revitt, D M; Scholes, L N L

    2005-01-01

    This paper presents the outcome of an inventory of planted wetland systems in the UK which are classified according to land use type and are all examples of sustainable drainage systems. The introduction of constructed wetlands to treat surface runoff essentially followed a 1997 Environment Agency for England and Wales report advocating the use of "soft engineered" facilities including wetlands in the context of sustainable development and Agenda 21. Subsequently published reports by the UK Construction Industry Research and Information Association (CIRIA) have promoted the potential benefits to both developer and the community of adopting constructed wetlands and other vegetated systems as a sustainable drainage approach. In addition, the UK Environment Agency and Highways Agency (HA) have recently published their own design criteria and requirements for vegetative control and treatment of road runoff. A case study of the design and performance of a constructed wetland system for the treatment of road runoff is discussed. The performance of these systems will be assessed in terms of their design criteria, runoff loadings as well as vegetation and structure maintenance procedures. The differing design approaches in guidance documents published in the UK by the Environment Agency, CIRIA and HA will also be evaluated.

  6. Sentinel node detection in early breast cancer with intraoperative portable gamma camera: UK experience.

    PubMed

    Ghosh, Debashis; Michalopoulos, Nikolaos V; Davidson, Timothy; Wickham, Fred; Williams, Norman R; Keshtgar, Mohammed R

    2017-04-01

    Access to nuclear medicine department for sentinel node imaging remains an issue in number of hospitals in the UK and many parts of the world. Sentinella ® is a portable imaging camera used intra-operatively to produce real time visual localisation of sentinel lymph nodes. Sentinella ® was tested in a controlled laboratory environment at our centre and we report our experience on the first use of this technology from UK. Moreover, preoperative scintigrams of the axilla were obtained in 144 patients undergoing sentinel node biopsy using conventional gamma camera. Sentinella ® scans were done intra-operatively to correlate with the pre-operative scintigram and to determine presence of any residual hot node after the axilla was deemed to be clear based on the silence of the hand held gamma probe. Sentinella ® detected significantly more nodes compared with CGC (p < 0.0001). Sentinella ® picked up extra nodes in 5/144 cases after the axilla was found silent using hand held gamma probe. In 2/144 cases, extra nodes detected by Sentinella ® confirmed presence of tumour cells that led to a complete axillary clearance. Sentinella ® is a reliable technique for intra-operative localisation of radioactive nodes. It provides increased nodal visualisation rates compared to static scintigram imaging and proves to be an important tool for harvesting all hot sentinel nodes. This portable gamma camera can definitely replace the use of conventional lymphoscintigrams saving time and money both for patients and the health system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Lymphatic drainage in renal cell carcinoma: back to the basics.

    PubMed

    Karmali, Riaz J; Suami, Hiroo; Wood, Christopher G; Karam, Jose A

    2014-12-01

    Lymphatic drainage in renal cell carcinoma (RCC) is unpredictable, however, basic patterns can be observed in cadaveric and sentinel lymph node mapping studies in patients with RCC. The existence of peripheral lymphovenous communications at the level of the renal vein has been shown in mammals but remains unknown in humans. The sentinel lymph node biopsy technique can be safely applied to map lymphatic drainage patterns in patients with RCC. Further standardisation of sentinel node biopsy techniques is required to improve the clinical significance of mapping studies. Understanding lymphatic drainage in RCC may lead to an evidence-based consensus on the surgical management of retroperitoneal lymph nodes. © 2014 The Authors. BJU International © 2014 BJU International.

  8. A first-in-man study of 68Ga-nanocolloid PET-CT sentinel lymph node imaging in prostate cancer demonstrates aberrant lymphatic drainage pathways.

    PubMed

    Doughton, Jacki A; Hofman, Michael S; Eu, Peter; Hicks, Rodney J; Williams, Scott G

    2018-05-04

    Purpose: To assess feasibility, safety and utility of a novel 68 Ga-nanocolloid radio-tracer with PET-CT lymphoscintigraphy for identification of sentinel lymph nodes (SLN). Methods: Pilot study of patients from a tertiary cancer hospital who required insertion of gold fiducials for prostate cancer radiation therapy. Participation did not affect cancer management. Ultrasound-guided transperineal intra-prostatic injection of PET tracer (iron oxide nanocolloid labelled with gallium-68) after placement of fiducials. PET-CT lymphoscintigraphy imaging at approximately 45 and 100 minutes after in-jection of tracer. The study was monitored using Bayesian trial design with the as-sumption that at least one sentinel lymph node (SLN) could be identified in at least two-thirds of cases with >80% confidence. Results: SLN identification was successful in all 5 participants, allowing completion of the pilot study as per protocol. No adverse effects were observed. Unexpected po-tential pathways for transit of malignant cells as well as expected regional drainage pathways were discovered. Rapid tracer drainage to pelvic bone, perivesical, mesorec-tal, inguinal and Virchow's nodes was identified. Conclusion: SLN identification using 68 Ga-nanocolloid PET-CT can be successfully performed. Non-traditional pathways of disease spread were identified including drainage to pelvic bone as well as perivesical, mesorectal, inguinal and Virchow's nodes. Prevalence of both aberrant and non-lymphatic pathways of spread should be further investigated with this technique. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. The history of sentinel node biopsy in head and neck cancer: From visualization of lymphatic vessels to sentinel nodes.

    PubMed

    de Bree, Remco; Nieweg, Omgo E

    2015-09-01

    The aim of this report is to describe the history of sentinel node biopsy in head and neck cancer. Sentinel node biopsy is a minimally invasive technique to select patients for treatment of metastatic lymph nodes in the neck. Although this procedure has only recently been accepted for early oral cancer, the first studies on visualization of the cervical lymphatic vessels were reported in the 1960s. In the 1980s mapping of lymphatic drainage from specific head and neck sites was introduced. Sentinel node biopsy was further developed in the 1990s and after validation in this century the procedure is routinely performed in early oral cancer in several head and neck centers. New techniques may improve the accuracy of sentinel node biopsy further, particularly in difficult subsites like the floor of mouth. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Surgical management of sentinel lymph node biopsy outside major nodal basin in patients with cutaneous melanoma.

    PubMed

    Caracò, Corrado; Marone, Ugo; Di Monta, Gianluca; Aloj, Luigi; Caracò, Corradina; Anniciello, Annamaria; Lastoria, Secondo; Botti, Gerardo; Mozzillo, Nicola

    2014-01-01

    To assess the incidence of nonmajor lymphatic basin sentinel nodes in patients with cutaneous melanoma in order to propose a correct nomenclature and inform appropriate surgical management. This was a retrospective review of 1,045 consecutive patients with cutaneous melanoma who underwent sentinel lymph node biopsy and dynamic lymphoscintigraphy to identify sentinel node site. Nonmajor drainage sites were classified as uncommon (located in a minor lymphatic basin along the lymphatic drainage to a major classical nodal basin) or interval (located anywhere along the lymphatics between the primary tumor site and the nearest lymphatic basin) sentinel nodes. Nonclassical sentinel nodes were identified in 32 patients (3.0 %). Uncommon sentinel nodes were identified in 3.2 % (n = 17) of trunk melanoma primary disease and in 1.5 % (n = 7) of upper and lower extremity sites. Interval sentinel nodes were identified in 1.3 % (n = 7) of trunk primary lesions, with none from upper and lower extremities melanomas. The incidence of tumor-positive sentinel nodes was 24.1 % (245 of 1,013) in classical sites and 12.5 % (4 of 32) in uncommon/interval sites. The definition of uncommon and interval sentinel nodes allows the identification of different lymphatic pathways and inform appropriate surgical treatment. Wider experience with uncommon/interval sentinel nodes will better clarify the clinical implications and surgical management to be adopted in the management of uncommon and interval sentinel node sites.

  11. Visualization of tumor blockage and rerouting of lymphatic drainage in penile cancer patients by use of SPECT/CT.

    PubMed

    Leijte, Joost A P; van der Ploeg, Iris M C; Valdés Olmos, Renato A; Nieweg, Omgo E; Horenblas, Simon

    2009-03-01

    The reliability of sentinel node biopsy is dependent on the accurate visualization and identification of the sentinel node(s). It has been suggested that extensive metastatic involvement of a sentinel node can lead to blocked inflow and rerouting of lymph fluid to a "neo-sentinel node" that may not yet contain tumor cells, causing a false-negative result. However, there is little evidence to support this hypothesis. Recently introduced hybrid SPECT/CT scanners provide both tomographic lymphoscintigraphy and anatomic detail. Such a scanner enabled the present study of the concept of tumor blockage and rerouting of lymphatic drainage in patients with palpable groin metastases. Seventeen patients with unilateral palpable and cytologically proven metastases in the groin underwent bilateral conventional lymphoscintigraphy and SPECT/CT before sentinel node biopsy of the contralateral groin. The pattern of lymphatic drainage in the 17 palpable groin metastases was evaluated for signs of tumor blockage or rerouting. On the CT images, the palpable node metastases could be identified in all 17 groins. Four of the 17 palpable node metastases (24%) showed uptake of radioactivity on the SPECT/CT images. In 10 groins, rerouting of lymphatic drainage to a neo-sentinel node was seen; one neo-sentinel node was located in the contralateral groin. A complete absence of lymphatic drainage was seen in the remaining 3 groins. The concept of tumor blockage and rerouting was visualized in 76% of the groins with palpable metastases. Precise physical examination and preoperative ultrasound with fine-needle aspiration cytology may identify nodes with considerable tumor invasion at an earlier stage and thereby reduce the incidence of false-negative results.

  12. Tracking surface and subsurface lakes on the Greenland Ice Sheet using Sentinel-1 SAR and Landsat-8 OLI imagery

    NASA Astrophysics Data System (ADS)

    Miles, Katie; Willis, Ian; Benedek, Corinne; Williamson, Andrew; Tedesco, Marco

    2017-04-01

    Supraglacial lakes (SGLs) on the Greenland Ice Sheet (GrIS) are an important component of the ice sheet's mass balance and hydrology, with their drainage affecting ice dynamics. This study uses imagery from the recently launched Sentinel-1A Synthetic Aperture Radar (SAR) to investigate SGLs in West Greenland. SAR can image through cloud and in darkness, overcoming some of the limitations of commonly used optical sensors. A semi automated algorithm is developed to detect surface lakes from Sentinel images during the 2015 summer. It generally detects water in all locations where a Landsat-8 NDWI classification (with a relatively high threshold value) detects water. A combined set of images from Landsat-8 and Sentinel-1 is used to track lake behaviour at a comparable temporal resolution to that which is possible with MODIS, but at a higher spatial resolution. A fully automated lake drainage detection algorithm is used to investigate both rapid and slow drainages for both small and large lakes through the summer. Our combined Landsat-Sentinel dataset, with a temporal resolution of three days, could track smaller lakes (mean 0.089 km2) than are resolvable in MODIS (minimum 0.125 km2). Small lake drainage events (lakes smaller than can be detected using MODIS) were found to occur at lower elevations ( 200 m) and slightly earlier in the melt season than larger events, as were slow lake drainage events compared to rapid events. The Sentinel imagery allows the analysis to be extended manually into the early winter to calculate the dates and elevations of lake freeze-through more precisely than is possible with optical imagery (mean 30 August, 1270 m mean elevation). Finally, the Sentinel imagery allows subsurface lakes (which are invisible to optical sensors) to be detected, and, for the first time, their dates of appearance and freeze-through to be calculated (mean 9 August and 7 October, respectively). These subsurface lakes occur at higher elevations than the surface

  13. Influence of previous breast surgery in sentinel lymph node biopsy in patients with breast cancer.

    PubMed

    López-Prior, V; Díaz-Expósito, R; Casáns Tormo, I

    The aim of this study was to review the feasibility of selective sentinel lymph node biopsy in patients with previous surgery for breast cancer, as well as to examine the factors that may interfere with sentinel node detection. A retrospective review was performed on 91 patients with breast cancer and previous breast surgery, and who underwent sentinel lymph node biopsy. Patients were divided into two groups according to their previous treatment: aesthetic breast surgery in 30 patients (group I) and breast-conserving surgery in 61 (group II). Lymphoscintigraphy was performed after an intra-tumour injection in 21 cases and a peri-areolar injection in 70 cases. An analysis was made of lymphatic drainage patterns and overall sentinel node detection according to clinical, pathological and surgical variables. The overall detection of the sentinel lymph node in the lymphoscintigraphy was 92.3%, with 7.7% of extra-axillary drainages. The identification rate was similar after aesthetic breast surgery (93.3%) and breast-conserving surgery (91.8%). Sentinel lymph nodes were found in the contralateral axilla in two patients (2.2%), and they were included in the histopathology study. The non-identification rate in the lymphoscintigraphy was 7.7%. There was a significantly higher non-detection rate in the highest histological grade tumours (28.6% grade III, 4.5% grade I and 3.6% grade II). Sentinel lymph node biopsy in patients with previous breast surgery is feasible and deserves further studies to assess the influence of different aspects in sentinel node detection in this clinical scenario. A high histological grade was significantly associated with a lower detection. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Towards monitoring surface and subsurface lakes on the Greenland Ice Sheet using Sentinel-1 SAR and Landsat-8 OLI imagery

    NASA Astrophysics Data System (ADS)

    Miles, Katie E.; Willis, Ian C.; Benedek, Corinne L.; Williamson, Andrew G.; Tedesco, Marco

    2017-07-01

    Supraglacial lakes are an important component of the Greenland Ice Sheet’s mass balance and hydrology, with their drainage affecting ice dynamics. This study uses imagery from the recently launched Sentinel-1A Synthetic Aperture Radar (SAR) satellite to investigate supraglacial lakes in West Greenland. A semi-automated algorithm is developed to detect surface lakes from Sentinel-1 images during the 2015 summer. A combined Landsat-8 and Sentinel-1 dataset, which has a comparable temporal resolution to MODIS (3 days versus daily) but a higher spatial resolution (25-40 m versus 250-500 m), is then used together with a fully-automated lake drainage detection algorithm. Rapid (< 4 days) and slow (> 4 days) drainages are investigated for both small (< 0.125 km2, the minimum size detectable by MODIS) and large (≥ 0.125 km2) lakes through the summer. Drainage events of small lakes occur at lower elevations (mean 159 m), and slightly earlier (mean 4.5 days) in the melt season than those of large lakes. The analysis is extended manually into the early winter to calculate the dates and elevations of lake freeze-through more precisely than is possible with optical imagery (mean 30 August; 1270 m mean elevation). Finally, the Sentinel-1 imagery is used to detect subsurface lakes and, for the first time, their dates of appearance and freeze-through (mean 9 August and 7 October, respectively). These subsurface lakes occur at higher elevations than the surface lakes detected in this study (mean 1593 m and 1185 m, respectively). Sentinel-1 imagery therefore provides great potential for tracking melting, water movement and freezing within both the firn zone and ablation area of the Greenland Ice Sheet.

  15. Meta-analysis of aberrant lymphatic drainage in recurrent breast cancer.

    PubMed

    Ahmed, M; Baker, R; Rubio, I T

    2016-11-01

    Sentinel node biopsy (SNB) in recurrent breast cancer offers targeted axillary staging compared with axillary lymph node dissection (ALND) or no treatment. The evidence for lymphatic mapping in recurrent breast cancer is reviewed, focusing on aberrant drainage and its implications for patient management. A meta-analysis of studies evaluating lymphatic mapping in recurrent breast cancer was performed. Outcomes included sentinel node identification, aberrant lymphatic pathways and metastatic node rates in aberrant drainage and ipsilateral axilla. Pooled odds ratios (ORs) and 95 per cent confidence intervals (c.i.) were estimated using fixed-effect analyses, or random-effects analyses in the event of statistically significant heterogeneity. Seven studies reported data on lymphatic mapping in 1053 patients with recurrent breast cancer. The intraoperative sentinel node identification rate was 59·6 (95 per cent c.i. 56·7 to 62·6) per cent, and significantly greater when the original axillary surgery was SNB compared with ALND (OR 2·97, 95 per cent c.i. 1·66 to 5·32). The rate of aberrant lymphatic drainage identification was 25·7 (23·0 to 28·3) per cent, and significantly greater when the original axillary surgery was ALND (OR 0·27, 0·19 to 0·38). The metastatic sentinel node rate was 10·4 (8·6 to 12·3) per cent, and a significantly greater metastatic nodal burden was identified in the ipsilateral axilla (OR 6·31, 1·03 to 38·79). Lymphatic mapping is feasible in recurrent breast cancer. It avoids ALND in over 50 per cent of patients who have undergone SNB, and allows the 4 per cent of patients with metastatically involved aberrant nodes to receive targeted surgical and adjuvant therapies. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

  16. Repeat sentinel lymph node biopsy in patients with ipsilateral recurrent breast cancer after breast-conserving therapy and negative sentinel lymph node biopsy: a prospective study.

    PubMed

    Folli, Secondo; Falco, Giuseppe; Mingozzi, Matteo; Buggi, Federico; Curcio, Annalisa; Ferrari, Guglielmo; Taffurelli, Mario; Regolo, Lea; Nanni, Oriana

    2016-04-01

    Patients with ipsilateral breast tumor recurrence or new ipsilateral primary tumor after previous breast conservative surgery with negative sentinel lymph node biopsy need a new axillary staging procedure. However, the best surgical option, i.e. repeat sentinel lymph node biopsy or axillary lymph node dissection, is still debated. Purpose of the study is to assess the performance of repeat sentinel lymph node biopsy. In a multicenter study, lymph node biopsy completed by back-up axillary lymph node dissection was undertaken for ipsilateral breast tumor recurrence or new ipsilateral primary tumor. Tracer uptake was used to identify and isolate the sentinel lymph node during surgery, and it was classified after staining with hematoxylin and eosin and monoclonal anti-cytokeratin antibodies. Aside from negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. A multicenter, prospective study was conducted performing 30 repeat sentinel lymph node biopsy completed by back-up axillary lymph node dissection for ipsilateral breast tumor recurrence or new ipsilateral primary tumor in patients formerly treated with previous breast conservative surgery and negative sentinel lymph node biopsy. Negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. Sentinel lymph nodes were mapped in 27 patients out of 30 (90%). Aberrant drainage pathways were observed in one patient (3.7%). Tracer uptake was sufficient to identify and isolate the sentinel lymph node during surgery in 23 cases (76.6%); the patients in whom lymphoscintigraphy failed or no sentinel lymph nodes could be isolated underwent axillary lymph node dissection. The negative predictive value was 95.2%, the accuracy was 95.6% and the false-negative rate was 33%. Repeat sentinel lymph node biopsy is feasible and accurate, with a high negative predictive value. Patients with ipsilateral breast tumor

  17. Improvement of the sentinel lymph node detection rate of cervical sentinel lymph node biopsy using real-time fluorescence navigation with indocyanine green in head and neck skin cancer.

    PubMed

    Nakamura, Yasuhiro; Fujisawa, Yasuhiro; Nakamura, Yoshiyuki; Maruyama, Hiroshi; Furuta, Jun-ichi; Kawachi, Yasuhiro; Otsuka, Fujio

    2013-06-01

    The standard technique using lymphoscintigraphy, blue dye and a gamma probe has established a reliable method for sentinel node biopsy for skin cancer. However, the detection rate of cervical sentinel lymph nodes (SLN) is generally lower than that of inguinal or axillary SLN because of the complexity of lymphatic drainage in the head and neck region and the "shine-through" phenomenon. Recently, indocyanine green fluorescence imaging has been reported as a new method to detect SLN. We hypothesized that fluorescence navigation with indocyanine green in combination with the standard technique would improve the detection rate of cervical sentinel nodes. We performed cervical sentinel node biopsies using the standard technique in 20 basins of 18 patients (group A) and using fluorescence navigation in combination with the standard technique in 12 basins of 16 patients (group B). The mean number of sentinel nodes was two per basin (range, 1-4) in group A and three per basin (range, 1-5) in group B. The detection rate of sentinel nodes was 83% (29/35) in group A and 95% (36/38) in group B. The false-negative rate was 6% (1/18 patients) in group A and 0% in group B. Fluorescence navigation with indocyanine green may improve the cervical sentinel node detection rate. However, greater collection of data regarding the usefulness of cervical sentinel node biopsy using indocyanine green is necessary. © 2013 Japanese Dermatological Association.

  18. Utilization of sentinel lymph node biopsy for uterine cancer.

    PubMed

    Wright, Jason D; Cham, Stephanie; Chen, Ling; Burke, William M; Hou, June Y; Tergas, Ana I; Desai, Vrunda; Hu, Jim C; Ananth, Cande V; Neugut, Alfred I; Hershman, Dawn L

    2017-06-01

    To limit the potential short and long-term morbidity of lymphadenectomy, sentinel lymph node biopsy has been proposed for endometrial cancer. The principle of sentinel lymph node biopsy relies on removal of a small number of lymph nodes that are the first drainage basins from a tumor and thus the most likely to harbor tumor cells. While the procedure may reduce morbidity, efficacy data are limited and little is known about how commonly the procedure is performed. We examined the patterns and predictors of use of sentinel lymph node biopsy and outcomes of the procedure in women with endometrial cancer who underwent hysterectomy. We used the Perspective database to identify women with uterine cancer who underwent hysterectomy from 2011 through 2015. Billing and charge codes were used to classify women as having undergone lymphadenectomy, sentinel lymph node biopsy, or no nodal assessment. Multivariable models were used to examine clinical, demographic, and hospital characteristics with use of sentinel lymph node biopsy. Length of stay and cost were compared among the different methods of nodal assessment. Among 28,362 patients, 9327 (32.9%) did not undergo nodal assessment, 17,669 (62.3%) underwent lymphadenectomy, and 1366 (4.8%) underwent sentinel lymph node biopsy. Sentinel lymph node biopsy was performed in 1.3% (95% confidence interval, 1.0-1.6%) of abdominal hysterectomies, 3.4% (95% confidence interval, 2.7-4.1%) of laparoscopic hysterectomies, and 7.5% (95% confidence interval, 7.0-8.0%) of robotic-assisted hysterectomies. In a multivariable model, more recent year of surgery was associated with performance of sentinel lymph node biopsy. Compared to abdominal hysterectomy, those undergoing laparoscopic (adjusted risk ratio, 2.45; 95% confidence interval, 1.89-3.18) and robotic-assisted (adjusted risk ratio, 2.69; 95% confidence interval, 2.19-3.30) hysterectomy were more likely to undergo sentinel lymph node biopsy. Among women who underwent minimally

  19. History, present status and future of sentinel node biopsy in breast cancer. The Mary Béves Lecture.

    PubMed

    Mansel, R E; Khonji, N I; Clarke, D

    2000-01-01

    The word Sentinel' is defined in The Oxford English Dictionary as 'a guard, one who keeps watch or a sentry'. When translated to the concept of a tumour and its lymph node drainage, the sentinel node could be interpreted to mean the lymph node that guards or keeps watch over a tumour. The sentinel lymph node can thus be defined as the first lymph node that drains a primary tumour within the regional lymphatic basin of that tumour. We know that tumour progression in breast cancer often occurs in an orderly, progressive fashion. So in theory, if the sentinel node is tumour free then the rest of the nodes in the lymphatic basin should also be uninvolved by the tumour.

  20. [The validity of the sentinel node concept in gastrointestinal cancers].

    PubMed

    Kitagawa, Y; Fujii, H; Mukai, M; Ando, N; Kubota, T; Ikeda, T; Ohgami, M; Watanabe, M; Otani, Y; Ozawa, S; Hasegawa, H; Furukawa, T; Nakahara, T; Kubo, A; Kumai, K; Kitajima, M

    2000-03-01

    Although the sentinel node concept has been validated and clinically applied to breast cancer and malignant melanoma, its clinical significance in other solid tumors has not been thoroughly investigated. With regard to gastrointestinal (GI) cancers in particular, our surgeons have been cautious because of the high frequency of skip metastasis and the complicated lymphatic system in the GI tract. We would like to emphasize that so-called skip metastasis has been defined according to anatomic classification of regional lymph nodes and that the lymphatic drainage route must be patient or lesion specific. To test the validity and feasibility of this concept in GI cancers, we have established a radio-guided intraoperative sentinel node navigation system using preoperative endoscopic submucosal injection of radioactive tracer followed by intra-operative gamma-probing. In 131 patients with GI cancers (esophagus: 22, stomach: 71, colorectum: 38), the detection rate of sentinel nades was 91% and overall diagnostic accuracy of lymph node metastasis by sentinel node status was 97%. Initial results suggest further investigation of this procedure as an accurate staging and a minimally invasive approach to early GI cancers.

  1. [Sentinel lymph node metastasis in patients with ductal breast carcinoma in situ].

    PubMed

    Ruvalcaba-Limón, Eva; de Jesús Garduño-Raya, María; Bautista-Piña, Verónica; Trejo-Martínez, Claudia; Maffuz-Aziz, Antonio; Rodríguez-Cuevas, Sergio

    2014-01-01

    Sentinel lymph node biopsy in patients with ductal carcinoma in situ still controversial, with positive lymph node in range of 1.4-12.5% due occult invasive breast carcinoma in surgical specimen. To know the frequency of sentimel node metastases in patients with ductal carcinoma in situ, identify differences between positive and negative cases. Retrospective study of patients with ductal carcinoma in situ treated with sentinel lymph node biopsy because mastectomy indication, palpable tumor, radiological lesion = 5 cm, non-favorable breast-tumor relation and/or patients whom surgery could affect lymphatic flow drainage. Of 168 in situ carcinomas, 50 cases with ductal carcinoma in situ and sentinel lymph node biopsy were included, with a mean age of 51.6 years, 30 (60%) asymptomatic. The most common symptoms were palpable nodule (18%), nipple discharge (12%), or both (8%). Microcalcifications were common (72%), comedonecrosis pattern (62%), grade-2 histology (44%), and 28% negative hormonal receptors. Four (8%) cases had intra-operatory positive sentinel lymph node and one patient at final histo-pathological study (60% micrometastases, 40% macrometastases), all with invasive carcinoma in surgical specimen. Patients with intra-operatory positive sentinel lymph node where younger (44.5 vs 51 years), with more palpable tumors (50% vs 23.1%), and bigger (3.5 vs 2 cm), more comedonecrosis pattern (75% vs 60.8%), more indifferent tumors (75% vs 39.1%), and less cases with hormonal receptors (50% vs 73.9%), compared with negative sentinel lymph node cases, all these differences without statistic significance. One of each 12 patients with ductal carcinoma in situ had affection in sentinel lymph node, so we recommend continue doing this procedure to avoid second surgeries due the presence of occult invasive carcinoma.

  2. Potential advantage of studying the lymphatic drainage by sentinel node technique and SPECT-CT image fusion for pelvic irradiation of prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krengli, Marco; Ballare, Andrea; Cannillo, Barbara

    2006-11-15

    Purpose: This study aims to investigate the in vivo drainage of lymphatic spread by using the sentinel node (SN) technique and single-photon emission computed tomography (SPECT)-computed tomography (CT) image fusion, and to analyze the impact of such information on conformal pelvic irradiation. Methods and Materials: Twenty-three prostate cancer patients, candidates for radical prostatectomy already included in a trial studying the SN technique, were enrolled. CT and SPECT images were obtained after intraprostate injection of 115 MBq of {sup 99m}Tc-nanocolloid, allowing identification of SN and other pelvic lymph nodes. Target and nontarget structures, including lymph nodes identified by SPECT, were drawnmore » on SPECT-CT fusion images. A three-dimensional conformal treatment plan was performed for each patient. Results: Single-photon emission computed tomography lymph nodal uptake was detected in 20 of 23 cases (87%). The SN was inside the pelvic clinical target volume (CTV{sub 2}) in 16 of 20 cases (80%) and received no less than the prescribed dose in 17 of 20 cases (85%). The most frequent locations of SN outside the CTV{sub 2} were the common iliac and presacral lymph nodes. Sixteen of the 32 other lymph nodes (50%) identified by SPECT were found outside the CTV{sub 2}. Overall, the SN and other intrapelvic lymph nodes identified by SPECT were not included in the CTV{sub 2} in 5 of 20 (25%) patients. Conclusions: The study of lymphatic drainage can contribute to a better knowledge of the in vivo potential pattern of lymph node metastasis in prostate cancer and can lead to a modification of treatment volume with consequent optimization of pelvic irradiation.« less

  3. [Sentinel node in melanoma and breast cancer. Current considerations].

    PubMed

    Vidal-Sicart, S; Vilalta Solsona, A; Alonso Vargas, M I

    2015-01-01

    The main objectives of sentinel node (SN) biopsy is to avoid unnecessary lymphadenectomies and to identify the 20-25% of patients with occult regional metastatic involvement. This technique reduces the associated morbidity from lymphadenectomy and increases the occult lymphatic metastases identification rate by offering the pathologist the or those lymph nodes with the highest probability of containing metastatic cells. Pre-surgical lymphoscintigraphy is considered a "road map" to guide the surgeon towards the sentinel nodes and to localize unpredictable lymphatic drainage patterns. The SPECT/CT advantages include a better SN detection rate than planar images, the ability to detect SNs in difficult to interpret studies, better SN depiction, especially in sites closer to the injection site and better anatomic localization. These advantages may result in a change in the patient's clinical management both in melanoma and breast cancer. The correct SN evaluation by pathology implies a tumoral load stratification and further prognostic implication. The use of intraoperative imaging devices allows the surgeon a better surgical approach and precise SN localization. Several studies reports the added value of such devices for more sentinel nodes excision and a complete monitoring of the whole procedure. New techniques, by using fluorescent or hybrid tracers, are currently being developed. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  4. Near infrared imaging to identify sentinel lymph nodes in invasive urinary bladder cancer

    NASA Astrophysics Data System (ADS)

    Knapp, Deborah W.; Adams, Larry G.; Niles, Jacqueline D.; Lucroy, Michael D.; Ramos-Vara, Jose; Bonney, Patty L.; deGortari, Amalia E.; Frangioni, John V.

    2006-02-01

    Approximately 12,000 people are diagnosed with invasive transitional cell carcinoma of the urinary bladder (InvTCC) each year in the United States. Surgical removal of the bladder (cystectomy) and regional lymph node dissection are considered frontline therapy. Cystectomy causes extensive acute morbidity, and 50% of patients with InvTCC have occult metastases at the time of diagnosis. Better staging procedures for InvTCC are greatly needed. This study was performed to evaluate an intra-operative near infrared fluorescence imaging (NIRF) system (Frangioni laboratory) for identifying sentinel lymph nodes draining InvTCC. NIRF imaging was used to map lymph node drainage from specific quadrants of the urinary bladder in normal dogs and pigs, and to map lymph node drainage from naturally-occurring InvTCC in pet dogs where the disease closely mimics the human condition. Briefly, during surgery NIR fluorophores (human serum albumen-fluorophore complex, or quantum dots) were injected directly into the bladder wall, and fluorescence observed in lymphatics and regional nodes. Conditions studied to optimize the procedure including: type of fluorophore, depth of injection, volume of fluorophore injected, and degree of bladder distention at the time of injection. Optimal imaging occurred with very superficial injection of the fluorophore in the serosal surface of the moderately distended bladder. Considerable variability was noted from dog to dog in the pattern of lymph node drainage. NIR fluorescence was noted in lymph nodes with metastases in dogs with InvTCC. In conclusion, intra-operative NIRF imaging is a promising approach to improve sentinel lymph node mapping in invasive urinary bladder cancer.

  5. Sentinel-2 data exploitation with ESA's Sentinel-2 Toolbox

    NASA Astrophysics Data System (ADS)

    Gascon, Ferran; Ramoino, Fabrizzio; deanos, Yves-louis

    2017-04-01

    The Sentinel-2 Toolbox is a project kicked off by ESA in early 2014, under the umbrella of the ESA SEOM programme with the aim to provide a tool for visualizing, analysing, and processing the Sentinel-2 datasets. The toolbox is an extension of the SeNtinel Application Platform (SNAP), a project resulting from the effort of the developers of the Sentinel-1, Sentinel-2 and Sentinel-3 toolbox to provide a single common application framework suited for the mixed exploitation of SAR, high resolution optical and medium resolution optical datasets. All three development teams collaborate to drive the evolution of the common SNAP framework in a developer forum. In this triplet, the Sentinel-2 toolbox is dedicated to enhance SNAP support for high resolution optical imagery. It is a multi-mission toolbox, already providing support for Sentinel-2, RapidEye, Deimos, SPOT 1 to SPOT 5 datasets. In terms of processing algorithms, SNAP provides tools specific to the Sentinel-2 mission : • An atmospheric correction module, Sen2Cor, is integrated into the toolbox, and provides scene classification, atmospheric correction, cirrus detection and correction. The output L2A products can be opened seamlessly in the toolbox. • A multitemporal synthesis processor (L3) • A biophysical products processor (L2B) • A water processor • A deforestation detector • OTB tools integration • SNAP Engine for Cloud Exploitation along with a set of more generic tools for high resolution optical data exploitation. Together with the generic functionalities of SNAP this provides an ideal environment for designing multi-missions processing chains and producing value-added products from raw datasets. The use of SNAP is manifold and the desktop tools provides a rich application for interactive visualization, analysis and processing of data. But all tools available from SNAP can be accessed via command-line through the Graph Processing Framework (GPT), the kernel of the SNAP processing engine. This

  6. Sentinel lymph node mapping in breast cancer: a critical reappraisal of the internal mammary chain issue.

    PubMed

    Manca, G; Volterrani, D; Mazzarri, S; Duce, V; Svirydenka, A; Giuliano, A; Mariani, G

    2014-06-01

    Although, like the axilla, the internal mammary nodes (IMNs) are a first-echelon nodal drainage site in breast cancer, the importance of their treatment has long been debated. Seminal randomized trials have failed to demonstrate a survival benefit from surgical IMN dissection, and several retrospective studies have shown that IMNs are rarely the first site of recurrence. However, the recent widespread adoption of sentinel lymph node (SLN) biopsy has stimulated a critical reappraisal of such early results. Furthermore, the higher proportion of screening-detected cancers, improved imaging and techniques (i.e., lymphoscintigraphy for radioguided SLN biopsy) make it possible to visualize lymphatic drainage to the IMNs. The virtually systematic application of adjuvant systemic and/or loco-regional radiotherapy encourages re-examination of the significance of IMN metastases. Moreover, randomized trials testing the value of postmastectomy irradiation and a meta-analysis of 78 randomized trials have provided high levels of evidence that local-regional tumor control is associated with long-term survival improvements. This benefit was limited to trials that used systemic chemotherapy, which was not routinely administered in the earlier studies. However, the contribution from IMN treatment is unclear. Lymphoscintigraphic studies have shown that a significant proportion of breast cancers have primary drainage to the IMNs, including approximately 30% of medial tumors and 15% of lateral tumors. In the few studies where IMN biopsy was performed, 20% of sentinel IMNs were metastatic. The risk of IMN involvement is higher in patients with medial tumors and positive axillary nodes. IMN metastasis has prognostic significance, as recognized by its inclusion in the American Joint Committee on Cancer staging criteria, and seems to have similar prognostic importance as axillary nodal involvement. Although routine IMN evaluation might be indicated, it has not been routinely performed

  7. A Specific Mapping Study Using Fluorescence Sentinel Lymph Node Detection in Patients with Intermediate- and High-risk Prostate Cancer Undergoing Extended Pelvic Lymph Node Dissection.

    PubMed

    Nguyen, Daniel P; Huber, Philipp M; Metzger, Tobias A; Genitsch, Vera; Schudel, Hans H; Thalmann, George N

    2016-11-01

    Sentinel lymph node (SLN) detection techniques have the potential to change the standard of surgical care for patients with prostate cancer. We performed a lymphatic mapping study and determined the value of fluorescence SLN detection with indocyanine green (ICG) for the detection of lymph node metastases in intermediate- and high-risk patients undergoing radical prostatectomy and extended pelvic lymph node dissection. A total of 42 patients received systematic or specific ICG injections into the prostate base, the midportion, the apex, the left lobe, or the right lobe. We found (1) that external and internal iliac regions encompass the majority of SLNs, (2) that common iliac regions contain up to 22% of all SLNs, (3) that a prostatic lobe can drain into the contralateral group of pelvic lymph nodes, and (4) that the fossa of Marcille also receives significant drainage. Among the 12 patients who received systematic ICG injections, 5 (42%) had a total of 29 lymph node metastases. Of these, 16 nodes were ICG positive, yielding 55% sensitivity. The complex drainage pattern of the prostate and the low sensitivity of ICG for the detection of lymph node metastases reported in our study highlight the difficulties related to the implementation of SNL techniques in prostate cancer. There is controversy about how extensive lymph node dissection (LND) should be during prostatectomy. We investigated the lymphatic drainage of the prostate and whether sentinel node fluorescence techniques would be useful to detect node metastases. We found that the drainage pattern is complex and that the sentinel node technique is not able to replace extended pelvic LND. Copyright © 2016. Published by Elsevier B.V.

  8. ESA's Multi-mission Sentinel-1 Toolbox

    NASA Astrophysics Data System (ADS)

    Veci, Luis; Lu, Jun; Foumelis, Michael; Engdahl, Marcus

    2017-04-01

    exploitation of polarimetric data including speckle filters, decompositions, and classifiers. The Toolbox will also include tools for large data stacks, supervised and unsupervised classification, improved vector handling and change detection. Architectural improvements such as smart memory configuration, task queuing, and optimizations for complex data will provide better support and performance for very large products and stacks.In addition, a Cloud Exploitation Platform Extension (CEP) has been developed to add the capability to smoothly utilize a cloud computing platform where EO data repositories and high performance processing capabilities are available. The extension to the SENTINEL Application Platform would facilitate entry into cloud processing services for supporting bulk processing on high performance clusters. Since December 2016, the COMET-LiCS InSAR portal (http://comet.nerc.ac.uk/COMET-LiCS-portal/) has been live, delivering interferograms and coherence estimates over the entire Alpine-Himalayan belt. The portal already contains tens of thousands of products, which can be browsed in a user-friendly portal, and downloaded for free by the general public. For our processing, we use the facilities at the Climate and Environmental Monitoring from Space (CEMS). Here we have large storage and processing facilities to our disposal, and a complete duplicate of the Sentinel-1 archive is maintained. This greatly simplifies the infrastructure we had to develop for automated processing of large areas. Here we will give an overview of the current status of the processing system, as well as discuss future plans. We will cover the infrastructure we developed to automatically produce interferograms and its challenges, and the processing strategy for time series analysis. We will outline the objectives of the system in the near and distant future, and a roadmap for its continued development. Finally, we will highlight some of the scientific results and projects linked to the

  9. Role of sentinel lymph node biopsy in oral cancer.

    PubMed

    Calabrese, L; Bruschini, R; Ansarin, M; Giugliano, G; De Cicco, C; Ionna, F; Paganelli, G; Maffini, F; Werner, J A; Soutar, D

    2006-12-01

    Squamous cell carcinoma of the oral cavity represents about 2% of all malignant neoplasms and 47% of those developing in the head and neck area. The tongue is the most common site involved, and this incidence is increasing mainly in young people, possibly related to human papilloma virus infections. Prognosis depends on the stage: the 5-year survival rate of tongue squamous cell carcinoma, whatever the T stage, is 73% in pN0 cases, 40% in patients with positive nodes without extracapsular spread (pNl ECS-), and 29% when nodes are metastatic with extracapsular spread (pNl ECS+: p > or = 0.0001). Nodal micrometastases (cN0 pN1) are found in up to 50% of cN0 tongue squamous cell carcinoma patients operated on the neck. At present, no clinical, imaging staging modalities or biological markers are available to diagnose nodal micrometastases. The sentinel node biopsy has been tested since 1996 in order to find a solution to this problem. The sentinel node is the first node reached by the lymphatic stream, assuming an orderly and sequential drainage from the tumour site, and should be predictive of the nodal stage. According to the literature, sentinel node biopsy is a reliable technique in selected cN0 cases, but the procedure is still experimental and should not be performed outside validation trials. Successful application of sentinel node biopsy in the head and neck region requires surgical experience and specific technical devices, including pre-operative lymphoscintigraphy and intra-operative gamma-probe. Moreover, dynamic lymphoscintigraphy seems to be able to show the lymphatic stream from the primary tumour and could allow a selective neck dissection to be tailored thus reducing the related morbidity.

  10. COMET-LICSAR: Systematic Deformation Monitoring of Fault Zones and Volcanoes with the Sentinel-1 Constellation

    NASA Astrophysics Data System (ADS)

    Spaans, K.; Wright, T. J.; Hooper, A. J.; Hatton, E. L.; González, P. J.; Bhattarai, S.; Biggs, J.; Crippa, P.; Ebmeier, S. K.; Elliott, J.; Gaddes, M.; Li, Z.; Parsons, B.; Qiu, Q.; McDougall, A.; Walters, R. J.; Weiss, J. R.; Ziebart, M.

    2017-12-01

    The Sentinel-1 constellation represents a major advance in our ability to monitor our planet's hazardous tectonic and volcanic zones. Here we present the latest progress from COMET (*), where we are now providing deformation results to the community for volcanoes and the tectonic belts (**). COMET now responds routinely to most significant continental earthquakes - Sentinel-1 allows us to do this within a few days for most earthquakes. For example, after the M7.8 Kaikoura (New Zealand) earthquake we supplied a processed interferogram to the community just 5 hours and 37 minutes after the Sentinel-1 acquisition. By the end of 2017, we will be producing interferogram products systematically for all earthquakes larger than M 6.0. For deformation data to be useful for preparedness, we need accuracy on the order of 1 mm/yr or better. This requires mass processing of long time series of radar acquisitions. We are currently (July 2017) processing interferograms systematically for the entire Alpine-Himalayan belt ( 9000 x 2000 km) using our LiCSAR chain, making interferograms and coherence products available to the community. By December 2017, we plan to process a wider tectonic area and the majority of subaerial volcanoes. We currently serve displacement and coherence grids, but plan to provide average deformation rates and time series. Results are available through our dedicated portal (**), and are being linked to the ESA G-TEP and EPOS during 2017. We will show the latest results for tectonics and volcanism, and discuss how these can be used to build value-added products, including (i) maps of tectonic strain (ii) maps of seismic hazard (iii) volcano deformation alerts. The accuracy of these products will improve as the number of data products acquired by Sentinel-1 increases, and as the time series lengthen. *http://comet.nerc.ac.uk**http://comet.nerc.ac.uk/COMET-LiCS-portal/

  11. COMET-LICSAR: Systematic Deformation Monitoring of Fault Zones and Volcanoes with the Sentinel-1 Constellation

    NASA Astrophysics Data System (ADS)

    Spaans, K.; Wright, T. J.; Hooper, A. J.; Hatton, E. L.; González, P. J.; Bhattarai, S.; Biggs, J.; Crippa, P.; Ebmeier, S. K.; Elliott, J.; Gaddes, M.; Li, Z.; Parsons, B.; Qiu, Q.; McDougall, A.; Walters, R. J.; Weiss, J. R.; Ziebart, M.

    2016-12-01

    The Sentinel-1 constellation represents a major advance in our ability to monitor our planet's hazardous tectonic and volcanic zones. Here we present the latest progress from COMET (*), where we are now providing deformation results to the community for volcanoes and the tectonic belts (**). COMET now responds routinely to most significant continental earthquakes - Sentinel-1 allows us to do this within a few days for most earthquakes. For example, after the M7.8 Kaikoura (New Zealand) earthquake we supplied a processed interferogram to the community just 5 hours and 37 minutes after the Sentinel-1 acquisition. By the end of 2017, we will be producing interferogram products systematically for all earthquakes larger than M 6.0. For deformation data to be useful for preparedness, we need accuracy on the order of 1 mm/yr or better. This requires mass processing of long time series of radar acquisitions. We are currently (July 2017) processing interferograms systematically for the entire Alpine-Himalayan belt ( 9000 x 2000 km) using our LiCSAR chain, making interferograms and coherence products available to the community. By December 2017, we plan to process a wider tectonic area and the majority of subaerial volcanoes. We currently serve displacement and coherence grids, but plan to provide average deformation rates and time series. Results are available through our dedicated portal (**), and are being linked to the ESA G-TEP and EPOS during 2017. We will show the latest results for tectonics and volcanism, and discuss how these can be used to build value-added products, including (i) maps of tectonic strain (ii) maps of seismic hazard (iii) volcano deformation alerts. The accuracy of these products will improve as the number of data products acquired by Sentinel-1 increases, and as the time series lengthen. *http://comet.nerc.ac.uk**http://comet.nerc.ac.uk/COMET-LiCS-portal/

  12. Sentinel-2 mission status

    NASA Astrophysics Data System (ADS)

    Hoersch, Bianca

    2017-04-01

    The SENTINEL-2 mission is the European Multispectral Imaging Mission for the Copernicus joint initiative of the European Commission (EC) and the European Space Agency (ESA). The SENTINEL-2 mission includes 13-spectral band multispectral optical imager with different resolution (down to 10 m) and a swath width of 290km. It provides very short revisit times and rapid product delivery. The mission is composed of a constellation of two satellite units, SENTINEL-2A and SENTINEL-2B, sharing the same orbital plane and featuring a short repeat cycle of 5 days at the equator optimized to mitigate the impact of clouds for science and applications. SENTINEL-2 enables exploitation for a variety of land and coastal applications such as agriculture, forestry, land cover and land cover change, urban mapping, emergency, as well as inland water, ice, glaciers and also coastal zone and closed seas applications. Following the launch of the Sentinel-2A in June 2015 and successful operations and data delivery since December 2015, the Sentinel-2B satellite is set for launch in March 2017. The full operation capacity is foreseen after the in-orbit commissioning phase of the Sentinel-2B unit in early summer 2017. The objective of the talk is to provide information about the mission status, and the way to achieve full operational capacity with 2 satellites.

  13. Multimodal fusion imaging ensemble for targeted sentinel lymph node management: initial results of an innovative promising approach for anatomically difficult lymphatic drainage in different tumour entities.

    PubMed

    Maza, Sofiane; Taupitz, Mathias; Taymoorian, Kasra; Winzer, Klaus Jürgen; Rückert, Jens; Paschen, Christian; Räber, Gert; Schneider, Sylke; Trefzer, Uwe; Munz, Dieter L

    2007-03-01

    There are situations where exact identification and localisation of sentinel lymph nodes (SLNs) are very difficult using lymphoscintigraphy, a hand-held gamma probe and vital dye, either a priori or a posteriori. We developed a new method using a simultaneous injection of two lymphotropic agents for exact topographical tomographic localisation and biopsy of draining SLNs. The purpose of this prospective pilot study was to investigate the feasibility and efficacy of this method ensemble. Fourteen patients with different tumour entities were enrolled. A mixture of (99m)Tc-nanocolloid and a dissolved superparamagnetic iron oxide was injected interstitially. Dynamic, sequential static lymphoscintigraphy and SPECT served as pathfinders. MR imaging was performed 2 h after injection. SPECT, contrast MRI and, if necessary, CT scan data sets were fused and evaluated with special regard to the topographical location of SLNs. The day after injection, nine patients underwent SLN biopsy and, in the presence of SLN metastasis, an elective lymph node dissection. Twenty-five SLNs were localised in the 14 patients examined. A 100% fusion correlation was achieved in all patients. The anatomical sites of SLNs detected during surgery showed 100% agreement with those localised on the multimodal fusion images. SLNs could be excised in 11/14 patients, six of whom had nodal metastasis. Our novel approach of multimodal fusion imaging for targeted SLN management in primary tumours with lymphatic drainage to anatomically difficult regions enables SLN biopsy even in patients with lymphatic drainage to obscure regions. Currently, we are testing its validity in larger patient groups and other tumour entities.

  14. Sexually selected sentinels? Evidence of a role for intrasexual competition in sentinel behavior

    PubMed Central

    Walker, Lindsay A.; York, Jenny E.

    2016-01-01

    Although the evolutionary mechanisms that favor investment in cooperative behaviors have long been a focus of research, comparatively few studies have considered the role that sexual selection may play. For example, evolutionary explanations for sentinel behavior (where 1 individual assumes an elevated position and scans the surroundings while other group members forage nearby) have traditionally focused on the inclusive fitness benefits arising from its effects on predation risk, while its potential role in defense against intrasexual competitors remains largely unexplored. Here, we provide experimental evidence of a role for sentinel behavior in intrasexual competition, in a cooperatively breeding songbird, the white-browed sparrow weaver (Plocepasser mahali). First, dominant males sentinel substantially more than other group members (even when controlling for variation in age and body condition), consistent with a role for sentineling in intrasexual competition for mates and/or territory. Second, experimental playback of an unfamiliar male’s solo song elicited a marked increase in sentineling by the dominant male, and the vocal response to the playback also positively predicted his sentinel effort following the simulated intrusion. A second experiment also suggests that sentineling may facilitate mounting rapid anti-intruder responses, as responses to intruder-playback occurred significantly earlier when the dominant male was sentineling rather than foraging at playback onset. Together, our findings provide rare support for the hypothesis that sentinel behavior plays a role in intrasexual competition, and so highlight the potential for sexually selected direct benefits to shape its expression in this and other social vertebrates. PMID:27656086

  15. Sentinel lymph node mapping in gynecological oncology

    PubMed Central

    Du, Jiang; Li, Yaling; Wang, Qing; Batchu, Nasra; Zou, Junkai; Sun, Chao; Lv, Shulan; Song, Qing; Li, Qiling

    2017-01-01

    The intraoperative mapping of sentinel lymph nodes (SLNs) is part of the treatment strategy for a number of types of tumor. To retrospectively compare results from the mapping of pelvic SLNs for gynecological oncology, using distinct dyes, the present review was conducted to determine the clinical significance of SLN mapping for gynecological oncology. In addition, the present study aimed at identifying an improved choice for SLN mapping tracers in clinical application. Each dye exhibits demerits when applied in the clinical environment. The combination of radioisotopes and blue dyes was identified to exhibit the most accurate detection rate of SLN drainage of gynecological oncology. However, contrast agents were unable to identify whether a SLN is positive or negative for metastasis prior to pathologic examination; additional studies are required. PMID:29344213

  16. Land science with Sentinel-2 and Sentinel-3 data series synergy

    NASA Astrophysics Data System (ADS)

    Moreno, Jose; Guanter, Luis; Alonso, Luis; Gomez, Luis; Amoros, Julia; Camps, Gustavo; Delegido, Jesus

    2010-05-01

    Although the GMES/Sentinel satellite series were primarily designed to provide observations for operational services and routine applications, there is a growing interest in the scientific community towards the usage of Sentinel data for more advanced and innovative science. Apart from the improved spatial and spectral capabilities, the availability of consistent time series covering a period of over 20 years opens possibilities never explored before, such as systematic data assimilation approaches exploiting the time-series concept, or the incorporation in the modelling approaches of processes covering time scales from weeks to decades. Sentinel-3 will provide continuity to current ENVISAT MERIS/AATSR capabilities. The results already derived from MERIS/AATRS will be more systematically exploited by using OLCI in synergy with SLST. Particularly innovative is the case of Sentinel-2, which is specifically designed for land applications. Built on a constellation of two satellites operating simultaneously to provide 5 days geometric revisit time, the Sentinel-2 system will providing global and systematic acquisitions with high spatial resolution and with a high revisit time tailored towards the needs of land monitoring. Apart from providing continuity to Landsat and SPOT time series, the Sentinel-2 Multi-Spectral Instrument (MSI) incorporates new narrow bands around the red-edge for improved retrievals of biophysical parameters. The limitations imposed by the need of a proper cloud screening and atmospheric corrections have represented a serious constraint in the past for optical data. The fact that both Sentinel-2 and 3 have dedicated bands to allow such needed corrections for optical data represents an important step towards a proper exploitation, guarantying consistent time series showing actual variability in land surface conditions without the artefacts introduced by the atmosphere. Expected operational products (such as Land Cover maps, Leaf Area Index

  17. Data mining tools for Sentinel 1 and Sentinel 2 data exploitation

    NASA Astrophysics Data System (ADS)

    Espinoza Molina, Daniela; Datcu, Mihai

    2016-10-01

    With the new planned Sentinel missions, the availability of Earth Observation data is increasing everyday offering a larger number of applications that can be created using these data. Currently, three of the five missions were launched and they are delivering a wealth of data and imagery of the Earth's surface as, for example, the Sentinel-1 carries an advanced radar instrument to provide an all-weather, day-and-night supply of Earth imagery. The second mission, the Sentinel-2, carries an optical instrument payload that will sample 13 spectral bands at different resolutions. Even though, we count on tools for automated loading and visual exploration of the Sentinel data, we still face the problem of extracting relevant structures from the images, finding similar patterns in a scene, exploiting the data, and creating final user applications based on these processed data. In this paper, we present our approach for processing radar and multi-spectral Sentinel data. Our approach is mainly composed of three steps: 1) the generation of a data model that explains the information contained in a Sentinel product. The model is formed by primitive descriptors and metadata entries, 2) the storage of this model in a database system, 3) the semantic definition of the image content based on machine learning algorithms and relevance feedback methods.

  18. Peat drainage conditions assessment in Scotland

    NASA Astrophysics Data System (ADS)

    Poggio, Laura; Artz, Rebekka; Donaldson-Selby, Gillian; Aitkenhead, Matt; Donnelly, David; Gimona, Alessandro

    2017-04-01

    Large areas of Scotland are covered in peat, providing an important sink of carbon but also a notable source of emission where peatlands are not in good condition. However, despite data from designated sites that peat degradation is common, a detailed spatial assessment of the condition of most peatlands across the whole of Scotland is missing. An assessment of peatland drainage was carried out at >600 random sampling locations with an expert-based estimation of presence or absence of drainage ditches within a 500 metre block using 25 cm resolution aerial imagery. The resulting dataset was modelled using a scorpan-kriging approach, in particular using Generalised Additive Models for the description of the trend. Remote sensing images from different sensors (i.e. MODIS, Landsat and Sentinel 1 and 2) were used. In particular we used indices describing vegetation greenness (Enhanced Vegetation Index), water availability (Normalised Water Difference index), Land Surface Temperature and vegetation productivity. When considering MODIS indices we used time series and phenological summaries. The model provides also uncertainty of the estimations. The derived dataset can then be used in the decision making process for the selection of sites for restoration, emissions estimation and accounting.

  19. Sensor sentinel computing device

    DOEpatents

    Damico, Joseph P.

    2016-08-02

    Technologies pertaining to authenticating data output by sensors in an industrial environment are described herein. A sensor sentinel computing device receives time-series data from a sensor by way of a wireline connection. The sensor sentinel computing device generates a validation signal that is a function of the time-series signal. The sensor sentinel computing device then transmits the validation signal to a programmable logic controller in the industrial environment.

  20. Sentinel-1 mission scientific exploitation activities

    NASA Astrophysics Data System (ADS)

    Desnos, Yves louis; Foumelis, Michael; Engdahl, Marcus

    2017-04-01

    The Sentinel-1 mission is the European Imaging Radar Observatory for the Copernicus joint initiative of the European Commission (EC) and the European Space Agency (ESA). Sentinel-1 mission is composed of a constellation of two satellites, Sentinel-1A and Sentinel-1B (launched in April 2014 and April 2016, respectively), sharing the same orbital plane and featuring a short repeat cycle of 6 days optimised for Synthetic Aperture Radar (SAR) interferometry science and applications. The full operation capacity was achieved after the completion of the Sentinel-1B in-orbit commissioning on 14 September 2016. Sentinel-1 data are freely available via the ESA's Sentinels Scientific Data Hub since October 2014. The data uptake by the science community has been unprecedented and numerous results have been published to date. The objective of the current paper is to provide a brief overview of the latest ESA activities, in the frame of the Scientific Exploitation of Operational Missions (SEOM) programme, aimed to facilitate the scientific exploitation of Sentinel-1 mission as well as discuss future opportunities for research.

  1. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer.

    PubMed

    van Rijk, Maartje C; Tanis, Pieter J; Nieweg, Omgo E; Loo, Claudette E; Olmos, Renato A Valdés; Oldenburg, Hester S A; Rutgers, Emiel J Th; Hoefnagel, Cornelis A; Kroon, Bin B R

    2007-02-01

    Preliminary data have shown encouraging results of a single intratumoral radiopharmaceutical injection that enables both sentinel node biopsy and probe-guided excision of the primary tumor in patients with nonpalpable breast cancer. The aim of the study was to evaluate this approach in a large group of patients. Lymphoscintigraphy was performed in 368 patients with nonpalpable breast cancer after intratumoral injection of (99m)Tc-nanocolloid (.2 mL, 123 MBq, 3.3 mCi) guided by ultrasound or stereotaxis. The sentinel node was pursued with the aid of vital blue dye (1.0 mL, intratumoral) and a gamma ray detection probe. In case of breast-conserving surgery, the probe was used to guide the excision. At least one sentinel node could be identified intraoperatively in 357 patients (97%), of whom 69 had involved nodes (19%). Age over 60 years was associated with less frequent nonaxillary lymphatic drainage and absence of internal mammary chain dissemination. Tumor-free margins were obtained in 262 (89%) of the 293 patients who underwent segmental excision. Re-excision of the primary tumor bed was performed in six patients (2%). During a median follow-up of 22 months, one breast recurrence and one axillary recurrence were observed. Lymphatic mapping and probe-guided tumor excision of nonpalpable breast cancer by intralesional administration of a single dose of (99m)Tc-nanocolloid and blue dye resulted in 97% identification of the sentinel node and in tumor-free margins in 89% of the patients who underwent breast-conserving surgery. Longer follow-up is needed to substantiate the accuracy and safety of this technique.

  2. Sentinel-3 For Land Applications

    NASA Astrophysics Data System (ADS)

    Goryl, Philippe; Gobron, Nadine; Mecklenburg, Susanne; Donlon, Craig; Bouvet, Marc; Buongiorno, Alessandra; Wilson, Hilary

    2016-07-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in a routine, long-term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The launch of Sentinel-3 was successful last February 2016. The Sentinel-3 missions are jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT on the marine products and the satellite monitoring and control. All facilities supporting the Sentinel-3 operations are in place. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products to the users. For a detailed description of the core data products please see https://earth.esa.int/web/sentinel/missions/sentinel-3/data-products. On request from the European Commission, ESA and EUMETSAT are presently assessing the possibility to include further core data products, in particular on aerosol optical depth, fire monitoring and synergistic products over land. This paper will provide an update on the status of the mission operations after the initial months in orbit and provide in particular an overview on the status of the Sentinel-3

  3. Malignant melanoma (non-metastatic): sentinel lymph node biopsy.

    PubMed

    Pay, Andy

    2016-01-19

    The incidence of malignant melanoma has increased over the past 25 years in the UK, but death rates have remained fairly constant. The 5-year survival rate ranges from 20% to 95%, depending on disease stage. Risks are greater in white populations and in people with higher numbers of skin naevi. We conducted a systematic overview, aiming to answer the following clinical question: What is the evidence for performing a sentinel lymph node biopsy in people with malignant melanoma with clinically uninvolved lymph nodes? We searched: Medline, Embase, The Cochrane Library and other important databases up to October 2014 (Clinical Evidence overviews are updated periodically; please check our website for the most up-to-date version of this overview). At this update, searching of electronic databases retrieved 221 studies. After deduplication and removal of conference abstracts, 99 records were screened for inclusion in the overview. Appraisal of titles and abstracts led to the exclusion of 58 studies and the further review of 41 full publications. Of the 41 full articles evaluated, one systematic review and three RCTs were added at this update. We performed a GRADE evaluation for two PICO combinations. In this systematic overview, we evaluated the evidence for performing sentinel lymph node biopsy in people with malignant melanoma with clinically uninvolved lymph nodes.

  4. Sentinel-2B image quality commissioning phase results and Sentinel2 constellation performances

    NASA Astrophysics Data System (ADS)

    Languille, F.; Gaudel, A.; Vidal, B.; Binet, R.; Poulain, V.; Trémas, T.

    2017-09-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites on a polar sun-synchronous orbit with a revisit time of 5 days (with both satellites), a high field of view - 290km, 13 spectral bands in visible and shortwave infrared, and high spatial resolution - 10m, 20m and 60m. The Sentinel-2 mission offers a global coverage over terrestrial surfaces. The satellites acquire systematically terrestrial surfaces under the same viewing conditions in order to have temporal images stacks. The first satellite was launched in June 2015 and the second in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensured the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 Global Reference Image (GRI) geolocation performance assessment. This paper points on geometric image quality on Sentinel-2B commissioning phase. It relates to the methods and the performances obtained, as well as the comparison between S2A and S2B. This deals with geolocation and multispectral registration. A small focus is also done on the Sentinel-2 GRI which is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference leads to ensure an accurate multi-temporal registration -on refined Sentinel-2 products over GRI- which is also presented in this paper.

  5. Copernicus POD Service: Ready for Sentinel-3

    NASA Astrophysics Data System (ADS)

    Peter, H.; Fernández, J.; Escobar, D.; Féménias, P.; Flohrer, C.; Otten, M.

    2015-12-01

    The Copernicus POD Service is part of the Copernicus PDGS Ground Segment of the Sentinel missions. A GMV-led consortium is operating the Copernicus POD Service being in charge of generating precise orbital products and auxiliary data files for their use as part of the processing chains of the respective Sentinel PDGS. The Sentinel-1, -2 & -3 missions have different but very demanding requirements in terms of orbital accuracy and timeliness. Orbital products in Near Real Time (latency: 30 min), Short Time Critical (1.5 days) and Non-time Critical (20-30 days) are required. The accuracy requirements are very challenging, targeting 5 cm in 3D for Sentinel-1 and 2-3 cm in radial direction for Sentinel-3. Sentinel-3A carries, in addition to a GPS receiver a laser retro reflector and a DORIS receiver. On the one hand, the three different techniques GPS, SLR and DORIS make POD more complex but, on the other hand, it is very helpful to have independent techniques available for validation of the orbit results. The successful POD processing for Sentinel-1A is a good preparation for Sentinel-3A due to the similar demanding orbit accuracy requirements. The Copernicus POD Service is ready for Sentinel-3A and the service will process GPS and SLR data routinely and has the capacity to process DORIS in NTC and reprocessing campaigns. The three independent orbit determination techniques on Sentinel-3 offer big potential for scientific exploitation. Carrying all three techniques together makes the satellite, e.g., very useful for combining all the techniques on observation level as it could only be done for Jason-2 until now. The Sentinel POD Quality Working Group strongly supporting the CPOD Service delivers additional orbit solutions to validate the CPOD results independently. The recommendations from this body guarantee that the CPOD Service is updated following state-of-the-art algorithms, models and conventions. The QWG also focuses on the scientific exploitation of the

  6. Sen2Cor for Sentinel-2

    NASA Astrophysics Data System (ADS)

    Main-Knorn, Magdalena; Pflug, Bringfried; Louis, Jerome; Debaecker, Vincent; Müller-Wilm, Uwe; Gascon, Ferran

    2017-10-01

    In the frame of the Copernicus programme, ESA has developed and launched the Sentinel-2 optical imaging mission that delivers optical data products designed to feed downstream services mainly related to land monitoring, emergency management and security. The Sentinel-2 mission is the constellation of two polar orbiting satellites Sentinel-2A and Sentinel-2B, each one equipped with an optical imaging sensor MSI (Multi-Spectral Instrument). Sentinel-2A was launched on June 23rd, 2015 and Sentinel-2B followed on March 7th, 2017. With the beginning of the operational phase the constellation of both satellites enable image acquisition over the same area every 5 days or less. To use unique potential of the Sentinel-2 data for land applications and ensure the highest quality of scientific exploitation, accurate correction of satellite images for atmospheric effects is required. Therefore the atmospheric correction processor Sen2Cor was developed by Telespazio VEGA Deutschland GmbH on behalf of ESA. Sen2Cor is a Level-2A processor which main purpose is to correct single-date Sentinel-2 Level-1C Top-Of-Atmosphere (TOA) products from the effects of the atmosphere in order to deliver a Level-2A Bottom-Of-Atmosphere (BOA) reflectance product. Additional outputs are an Aerosol Optical Thickness (AOT) map, a Water Vapour (WV) map and a Scene Classification (SCL) map with Quality Indicators for cloud and snow probabilities. Telespazio France and DLR have teamed up in order to provide the calibration and validation of the Sen2Cor processor. Here we provide an overview over the Sentinel-2 data, processor and products. It presents some processing examples of Sen2Cor applied to Sentinel-2 data, provides up-to-date information about the Sen2Cor release status and recent validation results at the time of the SPIE Remote Sensing 2017.

  7. The unpredictability of lymphatic drainage from the ear in melanoma patients, and its implications for management.

    PubMed

    Peach, Howard S; van der Ploeg, Augustinus P T; Haydu, Lauren E; Stretch, Jonathan R; Shannon, Kerwin F; Uren, Roger F; Thompson, John F

    2013-05-01

    The ear is known to have variable lymphatic drainage. The purpose of this study was to define better the lymphatic drainage patterns of the ear by correlating the location of primary tumors, classified according to the embryologically derived anatomical subunits of the ear, with their mapped sentinel nodes (SNs) identified by lymphoscintigraphy (LS). Lymphatic drainage data for patients with a primary melanoma of the ear were reviewed and correlated with the precise primary melanoma site. Between 1993 and 2010, LS was performed in 111 patients with a primary melanoma on the ear, identifying 281 SNs in 195 lymph node (LN) fields. The mean numbers of SNs and LN fields identified by LS per patient were 2.65 and 1.76. SN biopsy was performed in 71 patients (64 %). The mean number of SNs removed was 2.36. The 111 ear melanomas were mostly located on the helical rim (55 %), followed by the lobule (24.3 %). The five different primary ear sites drained mainly to SNs in level CII, level CV and the preauricular region. Drainage was most often to level CII (36.4 %). Drainage to the contralateral neck was not observed. Lymphatic drainage of the ear has no predictable pattern and can be to SNs anywhere in the ipsilateral neck. Most commonly drainage is to cervical level II and the preauricular and postauricular LN fields. LS defines the lymphatic drainage pattern in individual melanoma patients and is essential for accurate SN identification and reliable SN biopsy.

  8. Drainage after Modified Radical Mastectomy – A Methodological Mini-Review

    PubMed Central

    Tsocheva, Dragostina; Marinova, Katerina; Dobrev, Emil; Nenkov, Rumen

    2017-01-01

    Breast cancer is a socially relevant group of malignant conditions of the mammary gland, affecting both males and females. Most commonly the surgical approach of choice is a modified radical mastectomy (MRM), due to it allowing for both the removal of the main tumor mass and adjacent glandular tissue, which are suspected of infiltration and multifocality of the process, and a sentinel axillary lymph node removal. Most common post-surgical complications following MRM are the formation of a hematoma, the infection of the surgical wound and the formation of a seroma. These post-surgical complications can, at least in part, be attributed to the drainage of the surgical wound. However, the lack of modern and official guidelines provides an ample scope for innovation, but also leads to a need for a randomized comparison of the results. We compared different approaches to wound drainage after MRM, reviewed based on the armamentarium, number of drains, location, type of drainage system, timing of drain removal and no drainage alternatives. Currently, based on the general results, scientific and comparative discussions, seemingly the most affordable methodology with the best patient outcome, with regards to hospital stay and post-operative complications, is the placement of one medial to lateral (pectoro-axillary) drain with low negative pressure. Ideally, the drain should be removed on the second or third postoperative day or when the amount of drained fluid in the last 24 hours reaches below 50 milliliters. PMID:28929038

  9. The Sentinel 4 focal plane subsystem

    NASA Astrophysics Data System (ADS)

    Hohn, Rüdiger; Skegg, Michael P.; Hermsen, Markus; Hinger, Jürgen; Williges, Christian; Reulke, Ralf

    2017-09-01

    The Sentinel 4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program with the objective of monitoring trace gas concentrations. Sentinel 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Sentinel 4 is unique in being the first geostationary UVN mission. The SENTINEL 4 space segment will be integrated on EUMETSAT's Meteosat Third Generation Sounder satellite (MTG-S). Sentinel 4 will provide coverage of Europe and adjacent regions. The Sentinel 4 instrument comprises as a major element two Focal Plane Subsystems (FPS) covering the wavelength ranges 305 nm to 500 nm (UVVIS) and 750 nm to 775 nm (NIR) respectively. The paper describes the Focal Plane Subsystems, comprising the detectors, the optical bench and the control electronics. Further the design and development approach will be presented as well as first measurement results of FPS Qualification Model.

  10. Detection of breast cancer metastasis in sentinel lymph nodes using intra-operative real time GeneSearch BLN Assay in the operating room: results of the Cardiff study.

    PubMed

    Mansel, Robert E; Goyal, Amit; Douglas-Jones, Anthony; Woods, Victoria; Goyal, Sumit; Monypenny, Ian; Sweetland, Helen; Newcombe, Robert G; Jasani, Bharat

    2009-06-01

    Intra-operative assessment is not routinely performed in the UK due to poor sensitivity of available methods and overburdened pathology resources. We conducted a prospective clinical feasibility study of the GeneSearch Breast Lymph Node (BLN) Assay (Veridex, LLC, Warren, NJ) to confirm its potential usefulness within the UK healthcare system. In the assay 50% of the lymph node was processed to detect the presence of cytokeratin-19 and mammaglobin mRNA. The assay was calibrated to detect metastases >0.2 mm. Assay results were compared to H&E performed on each face of approximately 2 mm alternating node slabs and 3 additional sections cut at approximately 150 microm interval from each face of the node slab. 124 sentinel lymph nodes were removed from 82 breast cancer patients. The assay correctly identified all 6 patients with sentinel node macrometastases (>2.0 mm), and 2 of 3 patients with sentinel node micrometastases (0.2-2.0 mm). Sentinel lymph nodes in 4 patients were assay positive but histology negative. Two of these four patients had isolated tumor cells seen by histology. The overall concordance with histology was 93.9% (77/82), with sensitivity of 88.9% (8/9, 95% CI 56.5-98%), specificity of 94.6% (69/73, 95% CI 86.7-97.8%), positive predictive value of 66.7% (8/12, 95% CI 39.1-86.2%) and negative predictive value of 98.6% (69/70, 95% CI 92.3-99.7%). The assay was performed in a median time of 32 min (range 26-69 min). Intra-operative assessment of sentinel lymph node can be performed rapidly and accurately using the GeneSearch BLN Assay.

  11. Sentinels for snow science

    NASA Astrophysics Data System (ADS)

    Gascoin, S.; Grizonnet, M.; Baba, W. M.; Hagolle, O.; Fayad, A.; Mermoz, S.; Kinnard, C.; Fatima, K.; Jarlan, L.; Hanich, L.

    2017-12-01

    Current spaceborne sensors do not allow retrieving the snow water equivalent in mountain regions, "the most important unsolved problem in snow hydrology" (Dozier, 2016). While the NASA is operating an airborne mission to survey the SWE in the western USA, elsewhere, however, snow scientists and water managers do not have access to routine SWE measurements at the scale of a mountain range. In this presentation we suggest that the advent of the Copernicus Earth Observation programme opens new perspectives to address this issue in mountain regions worldwide. The Sentinel-2 mission will provide global-scale multispectral observations at 20 m resolution every 5-days (cloud permitting). The Sentinel-1 mission is already imaging the global land surface with a C-band radar at 10 m resolution every 6 days. These observations are unprecedented in terms of spatial and temporal resolution. However, the nature of the observation (radiometry, wavelength) is in the continuity of previous and ongoing missions. As a result, it is relatively straightforward to re-use algorithms that were developed by the remote sensing community over the last decades. For instance, Sentinel-2 data can be used to derive maps of the snow cover extent from the normalized difference snow index, which was initially proposed for Landsat. In addition, the 5-days repeat cycle allows the application of gap-filling algorithms, which were developed for MODIS based on the temporal dimension. The Sentinel-1 data can be used to detect the wet snow cover and track melting areas as proposed for ERS in the early 1990's. Eventually, we show an example where Sentinel-2-like data improved the simulation of the SWE in the data-scarce region of the High Atlas in Morocco through assimilation in a distributed snowpack model. We encourage snow scientists to embrace Sentinel-1 and Sentinel-2 data to enhance our knowledge on the snow cover dynamics in mountain regions.

  12. The sentinel behaviour of Arabian babbler floaters.

    PubMed

    Ostreiher, Roni; Heifetz, Aviad

    2017-02-01

    The sentinel behaviour of 38 Arabian babbler adult floaters, who lived alone within a territory belonging to a foreign group, was studied and compared with their own sentinel behaviour in the past, when they were group members. All floaters acted as sentinels and uttered 'alarm calls'. This suggests that sentinel activity is due at least, in part, to selfish motives. Floaters sentinelled less than they did as group members, with the decrease in sentinel activity sharper for ex-dominants than for ex-subordinates. One possible explanation for these differences is that sentinel activity is aimed not only at detecting predators, but also at detecting foreign conspecifics. Within a group, the latter incentive is stronger for breeding dominants than for subordinates, whereas all floaters alike may be trying to detect the owners of the territory in which they were roaming but also to avoid being detected by them. Other possible explanations are that floaters have less time and energy for sentinel activity because they are weaker or because foraging is more difficult in a foreign territory. This may be especially so for dominants who used to enjoy privileged access to food in their group. No significant difference was found in the rate of sentinels' 'alarm calls' between floaters and group members, suggesting that their main purpose is predator-prey communication, of which warning groupmates may be a side benefit.

  13. Malignant melanoma (non-metastatic): sentinel lymph node biopsy

    PubMed Central

    2016-01-01

    Introduction The incidence of malignant melanoma has increased over the past 25 years in the UK, but death rates have remained fairly constant. The 5-year survival rate ranges from 20% to 95%, depending on disease stage. Risks are greater in white populations and in people with higher numbers of skin naevi. Methods and outcomes We conducted a systematic overview, aiming to answer the following clinical question: What is the evidence for performing a sentinel lymph node biopsy in people with malignant melanoma with clinically uninvolved lymph nodes? We searched: Medline, Embase, The Cochrane Library and other important databases up to October 2014 (BMJ Clinical Evidence overviews are updated periodically; please check our website for the most up-to-date version of this overview). Results At this update, searching of electronic databases retrieved 221 studies. After deduplication and removal of conference abstracts, 99 records were screened for inclusion in the overview. Appraisal of titles and abstracts led to the exclusion of 58 studies and the further review of 41 full publications. Of the 41 full articles evaluated, one systematic review and three RCTs were added at this update. We performed a GRADE evaluation for two PICO combinations. Conclusions In this systematic overview, we evaluated the evidence for performing sentinel lymph node biopsy in people with malignant melanoma with clinically uninvolved lymph nodes. PMID:26788739

  14. Discovering Sentinel Rules for Business Intelligence

    NASA Astrophysics Data System (ADS)

    Middelfart, Morten; Pedersen, Torben Bach

    This paper proposes the concept of sentinel rules for multi-dimensional data that warns users when measure data concerning the external environment changes. For instance, a surge in negative blogging about a company could trigger a sentinel rule warning that revenue will decrease within two months, so a new course of action can be taken. Hereby, we expand the window of opportunity for organizations and facilitate successful navigation even though the world behaves chaotically. Since sentinel rules are at the schema level as opposed to the data level, and operate on data changes as opposed to absolute data values, we are able to discover strong and useful sentinel rules that would otherwise be hidden when using sequential pattern mining or correlation techniques. We present a method for sentinel rule discovery and an implementation of this method that scales linearly on large data volumes.

  15. The sentinel behaviour of Arabian babbler floaters

    PubMed Central

    Heifetz, Aviad

    2017-01-01

    The sentinel behaviour of 38 Arabian babbler adult floaters, who lived alone within a territory belonging to a foreign group, was studied and compared with their own sentinel behaviour in the past, when they were group members. All floaters acted as sentinels and uttered ‘alarm calls’. This suggests that sentinel activity is due at least, in part, to selfish motives. Floaters sentinelled less than they did as group members, with the decrease in sentinel activity sharper for ex-dominants than for ex-subordinates. One possible explanation for these differences is that sentinel activity is aimed not only at detecting predators, but also at detecting foreign conspecifics. Within a group, the latter incentive is stronger for breeding dominants than for subordinates, whereas all floaters alike may be trying to detect the owners of the territory in which they were roaming but also to avoid being detected by them. Other possible explanations are that floaters have less time and energy for sentinel activity because they are weaker or because foraging is more difficult in a foreign territory. This may be especially so for dominants who used to enjoy privileged access to food in their group. No significant difference was found in the rate of sentinels' ‘alarm calls’ between floaters and group members, suggesting that their main purpose is predator–prey communication, of which warning groupmates may be a side benefit. PMID:28386429

  16. Sentinel node biopsy in thin and thick melanoma.

    PubMed

    Mozzillo, Nicola; Pennacchioli, Elisabetta; Gandini, Sara; Caracò, Corrado; Crispo, Anna; Botti, Gerardo; Lastoria, Secondo; Barberis, Massimo; Verrecchia, Francesco; Testori, Alessandro

    2013-08-01

    Although sentinel node biopsy (SNB) has become standard of care in patients with melanoma, its use in patients with thin or thick melanomas remains a matter of debate. This was a retrospective analysis of patients with thin (≤1 mm) or thick (≥4 mm) melanomas who underwent SNB at two Italian centers between 1998 and 2011. The associations of clinicopathologic features with sentinel lymph node positive status and overall survival (OS) were analyzed. In 492 patients with thin melanoma, sentinel node was positive for metastatic melanoma in 24 (4.9 %) patients. No sentinel node positivity was detected in patients with primary tumor thickness <0.3 mm. Mitotic rate was the only factor significantly associated with sentinel node positivity (p = 0.0001). Five-year OS was 81 % for patients with positive sentinel node and 93 % for negative sentinel node (p = 0.001). In 298 patients with thick melanoma, 39 % of patients had positive sentinel lymph nodes (median Breslow thickness 5 mm). In patients with positive sentinel node, 93 % had mitotic rate >1/mm(2). Five-year OS was 49 % for patients with positive sentinel lymph nodes and 56 % for patients with negative sentinel nodes (p = 0.005). The rate of sentinel node positivity in patients with thin melanoma was 4.9 %. The only clinicopathologic factor related to node positivity was mitotic rate. Given its prognostic importance, SNB should be considered in such patients. SNB should also be the standard method for melanoma ≥4 mm, not only for staging, but also for guiding therapeutic decisions.

  17. SENTINEL-1 and SENTINEL-2 Data Fusion for Wetlands Mapping: Balikdami, Turkey

    NASA Astrophysics Data System (ADS)

    Kaplan, G.; Avdan, U.

    2018-04-01

    Wetlands provide a number of environmental and socio-economic benefits such as their ability to store floodwaters and improve water quality, providing habitats for wildlife and supporting biodiversity, as well as aesthetic values. Remote sensing technology has proven to be a useful and frequent application in monitoring and mapping wetlands. Combining optical and microwave satellite data can help with mapping and monitoring the biophysical characteristics of wetlands and wetlands` vegetation. Also, fusing radar and optical remote sensing data can increase the wetland classification accuracy. In this paper, data from the fine spatial resolution optical satellite, Sentinel-2 and the Synthetic Aperture Radar Satellite, Sentinel-1, were fused for mapping wetlands. Both Sentinel-1 and Sentinel-2 images were pre-processed. After the pre-processing, vegetation indices were calculated using the Sentinel-2 bands and the results were included in the fusion data set. For the classification of the fused data, three different classification approaches were used and compared. The results showed significant improvement in the wetland classification using both multispectral and microwave data. Also, the presence of the red edge bands and the vegetation indices used in the data set showed significant improvement in the discrimination between wetlands and other vegetated areas. The statistical results of the fusion of the optical and radar data showed high wetland mapping accuracy, showing an overall classification accuracy of approximately 90 % in the object-based classification method. For future research, we recommend multi-temporal image use, terrain data collection, as well as a comparison of the used method with the traditional image fusion techniques.

  18. Geocoding uncertainty analysis for the automated processing of Sentinel-1 data using Sentinel-1 Toolbox software

    NASA Astrophysics Data System (ADS)

    Dostálová, Alena; Naeimi, Vahid; Wagner, Wolfgang; Elefante, Stefano; Cao, Senmao; Persson, Henrik

    2016-10-01

    One of the major advantages of the Sentinel-1 data is its capability to provide very high spatio-temporal coverage allowing the mapping of large areas as well as creation of dense time-series of the Sentinel-1 acquisitions. The SGRT software developed at TU Wien aims at automated processing of Sentinel-1 data for global and regional products. The first step of the processing consists of the Sentinel-1 data geocoding with the help of S1TBX software and their resampling to a common grid. These resampled images serve as an input for the product derivation. Thus, it is very important to select the most reliable processing settings and assess the geocoding uncertainty for both backscatter and projected local incidence angle images. Within this study, selection of Sentinel-1 acquisitions over 3 test areas in Europe were processed manually in the S1TBX software, testing multiple software versions, processing settings and digital elevation models (DEM) and the accuracy of the resulting geocoded images were assessed. Secondly, all available Sentinel-1 data over the areas were processed using selected settings and detailed quality check was performed. Overall, strong influence of the used DEM on the geocoding quality was confirmed with differences up to 80 meters in areas with higher terrain variations. In flat areas, the geocoding accuracy of backscatter images was overall good, with observed shifts between 0 and 30m. Larger systematic shifts were identified in case of projected local incidence angle images. These results encourage the automated processing of large volumes of Sentinel-1 data.

  19. A cost comparison of traditional drainage and SUDS in Scotland.

    PubMed

    Duffy, A; Jefferies, C; Waddell, G; Shanks, G; Blackwood, D; Watkins, A

    2008-01-01

    The Dunfermline Eastern Expansion (DEX) is a 350 ha mixed development which commenced in 1996. Downstream water quality and flooding issues necessitated a holistic approach to drainage planning and the site has become a European showcase for the application of Sustainable Urban Drainage Systems (SUDS). However, there is minimal data available regarding the real costs of operating and maintaining SUDS to ensure they continue to perform as per their design function. This remains one of the primary barriers to the uptake and adoption of SUDS. This paper reports on what is understood to be the only study in the UK where actual costs of constructing and maintaining SUDS have been compared to an equivalent traditional drainage solution. To compare SUDS costs with traditional drainage, capital and maintenance costs of underground storage chambers of analogous storage volumes were estimated. A whole life costing methodology was then applied to data gathered. The main objective was to produce a reliable and robust cost comparison between SUDS and traditional drainage. The cost analysis is supportive of SUDS and indicates that well designed and maintained SUDS are more cost effective to construct, and cost less to maintain than traditional drainage solutions which are unable to meet the environmental requirements of current legislation. (c) IWA Publishing 2008.

  20. Sentinel-2 Mission status

    NASA Astrophysics Data System (ADS)

    Hoersch, Bianca; Colin, Olivier; Gascon, Ferran; Arino, Olivier; Spoto, Francois; Marchese, Franco; Krassenburg, Mike; Koetz, Benjamin

    2016-04-01

    Copernicus is a joint initiative of the European Commission (EC) and the European Space Agency (ESA), designed to establish a European capacity for the provision and use of operational monitoring information for environment and security applications. Within the Copernicus programme, ESA is responsible for the development of the Space Component, a fully operational space-based capability to supply earth-observation data to sustain environmental information Services in Europe. The Sentinel missions are Copernicus dedicated Earth Observation missions composing the essential elements of the Space Component. In the global Copernicus framework, they are complemented by other satellites made available by third-parties or by ESA and coordinated in the synergistic system through the Copernicus Data-Access system versus the Copernicus Services. The Copernicus Sentinel-2 mission provides continuity to services relying on multi-spectral high-resolution optical observations over global terrestrial surfaces. Sentinel-2 capitalizes on the technology and the vast experience acquired in Europe and the US to sustain the operational supply of data for services such as forest monitoring, land cover changes detection or natural disasters management. The Sentinel-2 mission offers an unprecedented combination of the following capabilities: ○ Systematic global coverage of land surfaces: from 56°South to 84°North, coastal waters and Mediterranean sea; ○ High revisit: every 5 days at equator under the same viewing conditions with 2 satellites; ○ High spatial resolution: 10m, 20m and 60m; ○ Multi-spectral information with 13 bands in the visible, near infra-red and short wave infra-red part of the spectrum; ○ Wide field of view: 290 km. The data from the Sentinel-2 mission are available openly and freely for all users with online easy access since December 2015. The presentation will give a status report on the Sentinel-2 mission, and outlook for the remaining ramp-up Phase, the

  1. 75 FR 76018 - Third Annual Sentinel Initiative Public Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ...] Third Annual Sentinel Initiative Public Workshop AGENCY: Food and Drug Administration, HHS. ACTION... workshop: Third Annual Sentinel Initiative Public Workshop. Hosted by the Engelberg Center for Health Care..., including an update on Mini-Sentinel and related activities, near-term plans for FDA's Sentinel Initiative...

  2. Sentinel Network

    Cancer.gov

    The Sentinel Network is an integrated, electronic, national medical product safety initiative that compiles information about the safe and effective use of medical products accessible to patients and healthcare practitioners.

  3. Synergetic Use of Sentinel-1 and Sentinel-2 Data for Soil Moisture Mapping at 100 m Resolution.

    PubMed

    Gao, Qi; Zribi, Mehrez; Escorihuela, Maria Jose; Baghdadi, Nicolas

    2017-08-26

    The recent deployment of ESA's Sentinel operational satellites has established a new paradigm for remote sensing applications. In this context, Sentinel-1 radar images have made it possible to retrieve surface soil moisture with a high spatial and temporal resolution. This paper presents two methodologies for the retrieval of soil moisture from remotely-sensed SAR images, with a spatial resolution of 100 m. These algorithms are based on the interpretation of Sentinel-1 data recorded in the VV polarization, which is combined with Sentinel-2 optical data for the analysis of vegetation effects over a site in Urgell (Catalunya, Spain). The first algorithm has already been applied to observations in West Africa by Zribi et al., 2008, using low spatial resolution ERS scatterometer data, and is based on change detection approach. In the present study, this approach is applied to Sentinel-1 data and optimizes the inversion process by taking advantage of the high repeat frequency of the Sentinel observations. The second algorithm relies on a new method, based on the difference between backscattered Sentinel-1 radar signals observed on two consecutive days, expressed as a function of NDVI optical index. Both methods are applied to almost 1.5 years of satellite data (July 2015-November 2016), and are validated using field data acquired at a study site. This leads to an RMS error in volumetric moisture of approximately 0.087 m³/m³ and 0.059 m³/m³ for the first and second methods, respectively. No site calibrations are needed with these techniques, and they can be applied to any vegetation-covered area for which time series of SAR data have been recorded.

  4. Combined application of Sentinel2A data and growth modelling for novel monitoring and prediction of pasture yields

    NASA Astrophysics Data System (ADS)

    Verhoef, A.; Punalekar, S.; Quaife, T. L.; Humphries, D.; Reynolds, C.

    2017-12-01

    Currently, 30% of the world's land area is covered by permanent pasture. Grazing ruminants convert forage materials into milk and meat for human consumption; ruminant production is a key agricultural enterprise. Management of pasture farms (nutrient and herbi-/pesticides application, grazing rotations) is often suboptimal. Furthermore, adverse weather can have negative effects on pasture growth and quality. Near real-time herbage monitoring and prediction could help improve farm profitability. While the use of remote sensing (RS) in the context of arable crop growth prediction is becoming more established, the same is not true for pasture. However, recently launched Sentinel satellites offer real opportunities to exploit high spatio-temporal resolution datasets for effective monitoring of pastures, as well as crops. A perennial grazed ryegrass field in the Southwest of the UK was monitored regularly using field hyperspectral spectro-radiometers. Simultaneously, leaf area index (LAI) was measured using a ceptometer, and yield was measured, indirectly using a `plate meter' and directly by destructive sampling. Two sets of spectral data were used to retrieve LAI with the PROSAIL radiative transfer model: (i) Sentinel-2A bands convolved from field spectral data, (ii) actual Sentinel-2A image pixels for the sampling plots. Retrieved LAI was compared against field observations. LAI estimates were assimilated in a bespoke growth model (including grazing and management), driven by weather data, for calibration of sensitive parameters using a 4D-Var scheme, to obtain pasture biomass. The developed approach was used to study a pasture farm in the South of the UK, for which a large number of Sentinel-2A images were available throughout 2016-17. Retrieved LAI compared well with in-situ LAI, and significantly improved yield estimates. The calibrated model parameters compared well with literature values. The model, guided by satellite data and general information on farm

  5. Zika beyond the Americas: Travelers as sentinels of Zika virus transmission. A GeoSentinel analysis, 2012 to 2016.

    PubMed

    Leder, Karin; Grobusch, Martin P; Gautret, Philippe; Chen, Lin H; Kuhn, Susan; Lim, Poh Lian; Yates, Johnnie; McCarthy, Anne E; Rothe, Camilla; Kato, Yasuyuki; Bottieau, Emmanuel; Huber, Kristina; Schwartz, Eli; Stauffer, William; Malvy, Denis; Shaw, Marc T M; Rapp, Christophe; Blumberg, Lucille; Jensenius, Mogens; van Genderen, Perry J J; Hamer, Davidson H

    2017-01-01

    Zika virus (ZIKV) was first isolated in Africa; decades later, caused large outbreaks in the Pacific, and is considered endemic in Asia. We aim to describe ZIKV disease epidemiology outside the Americas, the importance of travelers as sentinels of disease transmission, and discrepancies in travel advisories from major international health organizations. This descriptive analysis using GeoSentinel Surveillance Network records involves sixty-four travel and tropical medicine clinics in 29 countries. Ill returned travelers with a confirmed or probable diagnosis of ZIKV disease acquired in Africa, Asia and the Pacific seen between 1 January 2012 and 31 December 2016 are included, and the frequencies of demographic, trip, and diagnostic characteristics described. ZIKV was acquired in Asia (18), the Pacific (10) and Africa (1). For five countries (Indonesia, Philippines, Thailand, Vietnam, Cameroon), GeoSentinel patients were sentinel markers of recent Zika activity. Additionally, the first confirmed ZIKV infection acquired in Kiribati was reported to GeoSentinel (2015), and a probable case was reported from Timor Leste (April 2016), representing the only case known to date. Review of Zika situation updates from major international health authorities for country risk classifications shows heterogeneity in ZIKV country travel advisories. Travelers are integral to the global spread of ZIKV, serving as sentinel markers of disease activity. Although GeoSentinel data are collected by specialized clinics and do not capture all imported cases, we show that surveillance of imported infections by returned travelers augments local surveillance system data regarding ZIKV epidemiology and can assist with risk categorization by international authorities. However, travel advisories are variable due to risk uncertainties.

  6. [Risk factors of non-sentinel lymph node metastasis in breast cancer patients with positive sentinel lymph node ≤ 2].

    PubMed

    Gao, Yajun; He, Yingjian; Fan, Zhaoqing; Ouyang, Tao

    2014-08-13

    To explore retrospectively the risk factors of non-sentinel lymph node (NSLN) metastasis in breast cancer patients with sentinel lymph node metastasis ≤ 2 and examine the likelihood of non-sentinel lymph node prediction. A sentinel lymph node biopsy database containing 455 breast cancer patients admitted between July 2005 and February 2012 at Beijing Cancer Hospital was analyzed retrospectively. The patients had ≤ 2 positive sentinel lymph node and complete axillary lymph node dissection. The SLNS⁺/SLNS ratio (P = 0.001), histological grade (P = 0.075), size of mass (P = 0.023) and onset age (P = 0.074) were correlated with NSLN metastases. Only SLNS⁺/SLNS (OR 0.502 95% CI 0.322-0.7844) , histological grade ratio (histological grade ratio II, III and others vs grade I OR 2.696, 2.102, 3.662) were significant independent predictors for NSLN metastases . The ROC value was 0.62 (0.56, 0.68). For ≤ 2 positive sentinel lymph nodes of breast cancer, ratio of SLNS⁺/SLNS and histological grading are independent factors affecting NSLN metastases. However, the results remain unsatisfactory for predicting the status of NSLN.

  7. Sentinel Lymph Nodes for Breast Carcinoma A Paradigm Shift

    PubMed Central

    Maguire, Aoife; Brogi, Edi

    2016-01-01

    Context Sentinel lymph node biopsy has been established as the new standard of care for axillary staging in most patients with invasive breast carcinoma. Historically, all patients with a positive sentinel lymph node biopsy result underwent axillary lymph node dissection. Recent trials show that axillary lymph node dissection can be safely omitted in women with clinically node negative, T1 or T2 invasive breast cancer treated with breast-conserving surgery and whole-breast radiotherapy. This change in practice also has implications on the pathologic examination and reporting of sentinel lymph nodes. Objective To review recent clinical and pathologic studies of sentinel lymph nodes and explore how these findings influence the pathologic evaluation of sentinel lymph nodes. Data Sources Sources were published articles from peer-reviewed journals in PubMed (US National Library of Medicine) and published guidelines from the American Joint Committee on Cancer, the Union for International Cancer Control, the American Society of Clinical Oncology, and the National Comprehensive Cancer Network. Conclusions The main goal of sentinel lymph node examination should be to detect all macrometastases (>2 mm). Grossly sectioning sentinel lymph nodes at 2-mm intervals and evaluation of one hematoxylin-eosin–stained section from each block is the preferred method of pathologic evaluation. Axillary lymph node dissection can be safely omitted in clinically node-negative patients with negative sentinel lymph nodes, as well as in a selected group of patients with limited sentinel lymph node involvement. The pathologic features of the primary carcinoma and its sentinel lymph node metastases contribute to estimate the extent of non–sentinel lymph node involvement. This information is important to decide on further axillary treatment. PMID:27472237

  8. Sentinel Lymph Nodes for Breast Carcinoma: A Paradigm Shift.

    PubMed

    Maguire, Aoife; Brogi, Edi

    2016-08-01

    -Sentinel lymph node biopsy has been established as the new standard of care for axillary staging in most patients with invasive breast carcinoma. Historically, all patients with a positive sentinel lymph node biopsy result underwent axillary lymph node dissection. Recent trials show that axillary lymph node dissection can be safely omitted in women with clinically node negative, T1 or T2 invasive breast cancer treated with breast-conserving surgery and whole-breast radiotherapy. This change in practice also has implications on the pathologic examination and reporting of sentinel lymph nodes. -To review recent clinical and pathologic studies of sentinel lymph nodes and explore how these findings influence the pathologic evaluation of sentinel lymph nodes. -Sources were published articles from peer-reviewed journals in PubMed (US National Library of Medicine) and published guidelines from the American Joint Committee on Cancer, the Union for International Cancer Control, the American Society of Clinical Oncology, and the National Comprehensive Cancer Network. -The main goal of sentinel lymph node examination should be to detect all macrometastases (>2 mm). Grossly sectioning sentinel lymph nodes at 2-mm intervals and evaluation of one hematoxylin-eosin-stained section from each block is the preferred method of pathologic evaluation. Axillary lymph node dissection can be safely omitted in clinically node-negative patients with negative sentinel lymph nodes, as well as in a selected group of patients with limited sentinel lymph node involvement. The pathologic features of the primary carcinoma and its sentinel lymph node metastases contribute to estimate the extent of non-sentinel lymph node involvement. This information is important to decide on further axillary treatment.

  9. Synergetic Use of Sentinel-1 and Sentinel-2 Data for Soil Moisture Mapping at 100 m Resolution

    PubMed Central

    Gao, Qi; Zribi, Mehrez

    2017-01-01

    The recent deployment of ESA’s Sentinel operational satellites has established a new paradigm for remote sensing applications. In this context, Sentinel-1 radar images have made it possible to retrieve surface soil moisture with a high spatial and temporal resolution. This paper presents two methodologies for the retrieval of soil moisture from remotely-sensed SAR images, with a spatial resolution of 100 m. These algorithms are based on the interpretation of Sentinel-1 data recorded in the VV polarization, which is combined with Sentinel-2 optical data for the analysis of vegetation effects over a site in Urgell (Catalunya, Spain). The first algorithm has already been applied to observations in West Africa by Zribi et al., 2008, using low spatial resolution ERS scatterometer data, and is based on change detection approach. In the present study, this approach is applied to Sentinel-1 data and optimizes the inversion process by taking advantage of the high repeat frequency of the Sentinel observations. The second algorithm relies on a new method, based on the difference between backscattered Sentinel-1 radar signals observed on two consecutive days, expressed as a function of NDVI optical index. Both methods are applied to almost 1.5 years of satellite data (July 2015–November 2016), and are validated using field data acquired at a study site. This leads to an RMS error in volumetric moisture of approximately 0.087 m3/m3 and 0.059 m3/m3 for the first and second methods, respectively. No site calibrations are needed with these techniques, and they can be applied to any vegetation-covered area for which time series of SAR data have been recorded. PMID:28846601

  10. Sentinel 2 products and data quality status

    NASA Astrophysics Data System (ADS)

    Clerc, Sebastien; Gascon, Ferran; Bouzinac, Catherine; Touli-Lebreton, Dimitra; Francesconi, Benjamin; Lafrance, Bruno; Louis, Jerome; Alhammoud, Bahjat; Massera, Stephane; Pflug, Bringfried; Viallefont, Francoise; Pessiot, Laetitia

    2017-04-01

    Since July 2015, Sentinel-2A provides high-quality multi-spectral images with 10 m spatial resolution. With the launch of Sentinel-2B scheduled for early March 2017, the mission will create a consistent time series with a revisit time of 5 days. The consistency of the time series is ensured by some specific performance requirements such as multi-temporal spatial co-registration and radiometric stability, routinely monitored by the Sentinel-2 Mission Performance Centre (S2MPC). The products also provide a rich set of metadata and auxiliary data to support higher-level processing. This presentation will focus on the current status of the Sentinel-2 L1C and L2A products, including dissemination and product format aspects. Up-to-date mission performance estimations will be presented. Finally we will provide an outlook on the future evolutions: commissioning tasks for Sentinel-2B, geometric refinement, product format and processing improvements.

  11. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT).

    PubMed

    Brouwer, O R; Vermeeren, L; van der Ploeg, I M C; Valdés Olmos, R A; Loo, C E; Pereira-Bouda, L M; Smit, F; Neijenhuis, P; Vrouenraets, B C; Sivro-Prndelj, F; Jap-a-Joe, S M; Borgstein, P J; Rutgers, E J Th; Oldenburg, H S A

    2012-07-01

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were included prospectively at four centres in The Netherlands. Lymphatic flow was studied using planar lymphoscintigraphy and SPECT/CT until 4 h after administration of (99m)Tc-nanocolloid in the largest tumour. Subsequently, the smaller tumour(s) was injected intratumorally followed by the same imaging sequence. Sentinel nodes were intraoperatively localized using a gamma ray detection probe and vital blue dye. Included in the study were 50 patients. Additional lymphatic drainage was depicted after the second and/or third injection in 32 patients (64%). Comparison of planar images and SPECT/CT images after consecutive injections enabled visualization of the number and location of additional sentinel nodes (32 axillary, 11 internal mammary chain, 2 intramammary, and 1 interpectoral. A sentinel node contained metastases in 17 patients (34%). In five patients with a tumour-positive node in the axilla that was visualized after the first injection, an additional involved axillary node was found after the second injection. In two patients, isolated tumour cells were found in sentinel nodes that were only visualized after the second injection, whilst the sentinel nodes identified after the first injection were tumour-negative. Lymphoscintigraphy and SPECT/CT after consecutive intratumoral injections of tracer enable lymphatic mapping of each tumour separately in patients with multiple malignancies within one breast. The high incidence of additional sentinel nodes draining from tumours other than the largest one suggests that separate tumour-related tracer injections may be a more accurate approach to mapping and sampling of sentinel nodes in patients with multicentric or

  12. Prognostic Role of Multiple Lymphatic Basin Drainage in Sentinel Lymph Node-Negative Trunk Melanoma Patients: A Multicenter Study from the Italian Melanoma Intergroup.

    PubMed

    Ribero, Simone; Osella-Abate, Simona; Pasquali, Sandro; Rossi, Carlo Riccardo; Borgognoni, Lorenzo; Piazzalunga, Dario; Solari, Nicola; Schiavon, Mauro; Brandani, Paola; Ansaloni, Luca; Ponte, Erica; Silan, Francesco; Sommariva, Antonio; Bellucci, Francesco; Macripò, Giuseppe; Quaglino, Pietro

    2016-05-01

    Multiple lymphatic basin drainage (MLBD) is frequently observed in patients with trunk melanoma undergoing sentinel lymph node (SLN) biopsy. Conflicting data regarding the prognostic association of MLBD in SLN-negative patients have been reported. This study aimed to investigate the prognostic role of MLBD in patients with negative SLN biopsy. Retrospective data from 656 melanoma patients who underwent a SLN biopsy (1991-2012) at six Italian centers were gathered in a multicenter database. MLBD was defined as lymphoscintigraphic and intraoperative identification of an SLN in more than one nodal basin. Clinical and pathologic variables were recorded and analyzed for their impact on survival. SLN-negative patients with MLBD were at lower risk of melanoma recurrence [hazard ratio (HR) 0.73, P = 0.05) and melanoma-related death (HR 0.68, P = 0.001) independent of common staging features. Multivariable Cox analyses of disease-free interval (DFI) and disease-specific survival (DSS) showed that MLBD maintained a favorable role and ulceration an unfavorable role. Histologic regression was independently associated only with DFI. When survival was stratified according to presence of MLBD, histologic regression and Breslow thickness <2 mm were associated with improved DFI (5-year DFI: 96.9 vs. 66,1 %, respectively; HR 0.48, P < 0.001) and DSS (5-year DSS: 96.7 vs. 71.8 %, respectively; HR 0.52, P = 0.005) compared to patients without these three favorable parameters. Patients with negative SLN biopsy results have better prognosis when two or more lymphatic basins are identified and analyzed. Further research is required to investigate the mechanisms behind this evidence.

  13. [Presence of intramammary lymph nodes in the preoperative lymphoscintigraphy to locate the sentinel lymph node. Clinical significance].

    PubMed

    Nogareda, Z; Álvarez, A; Perlaza, P; Caparrós, F X; Alonso, I; Paredes, P; Vidal-Sicart, S

    2015-01-01

    The routes of lymphatic drainage from a breast cancer are the axilla (the most frequent) and the extra axillary regions. Among the latter, there are the so-called intrammamary lymph nodes (IMLN). This study has aimed to assess the incidence of IMLNs in our patients and study the evolution of these cases with IMLN in the lymphoscintigraphy. Thirty-eight patients (out of 1725) with IMLN in the pre-operative lymphoscintigraphy were assessed. During the surgical procedure, using a gamma probe, IMLNs were located and excised. After their harvesting, a meticulous surgical field scan was performed. When the axillary sentinel node was positive for metastasis, a complete axillary lymphadenectomy was performed. In those where the axillary sentinel node was negative and IMLN was positive (IMLN+), axillary lymphadenectomy was also performed, except for one case. Thirty-four out of the 38 IMLNs were obtained (89.5%), because no lymphatic tissue was found in pathology analysis in three cases (8%) and in one patient (3%) IMLN was not found during surgery. Ten (26%) metastatic IMLNs were located and the remaining 24 IMLNs cases (63%) were metastasis-free. During the clinical follow-up, one patient with IMLN+ developed hepatic metastases. The remaining 33 patients did not present any recurrence. No follow-up data were available for three patients. IMLN and axillary sentinel node biopsy are recommended when both are depicted in preoperative lymphoscintigraphy. The axilla treatment will only depend on the axillary sentinel node status. Based on the data from other authors and our own experience, avoiding the axillary lymphadenectomy when a metastatic IMLN without axillary involvement seems reasonable. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  14. Zika beyond the Americas: Travelers as sentinels of Zika virus transmission. A GeoSentinel analysis, 2012 to 2016.

    PubMed Central

    Grobusch, Martin P.; Gautret, Philippe; Kuhn, Susan; Lim, Poh Lian; Yates, Johnnie; McCarthy, Anne E.; Rothe, Camilla; Kato, Yasuyuki; Huber, Kristina; Schwartz, Eli; Shaw, Marc T. M.; Rapp, Christophe; Blumberg, Lucille; Jensenius, Mogens; van Genderen, Perry J. J.

    2017-01-01

    Background Zika virus (ZIKV) was first isolated in Africa; decades later, caused large outbreaks in the Pacific, and is considered endemic in Asia. We aim to describe ZIKV disease epidemiology outside the Americas, the importance of travelers as sentinels of disease transmission, and discrepancies in travel advisories from major international health organizations. Methods and findings This descriptive analysis using GeoSentinel Surveillance Network records involves sixty-four travel and tropical medicine clinics in 29 countries. Ill returned travelers with a confirmed or probable diagnosis of ZIKV disease acquired in Africa, Asia and the Pacific seen between 1 January 2012 and 31 December 2016 are included, and the frequencies of demographic, trip, and diagnostic characteristics described. ZIKV was acquired in Asia (18), the Pacific (10) and Africa (1). For five countries (Indonesia, Philippines, Thailand, Vietnam, Cameroon), GeoSentinel patients were sentinel markers of recent Zika activity. Additionally, the first confirmed ZIKV infection acquired in Kiribati was reported to GeoSentinel (2015), and a probable case was reported from Timor Leste (April 2016), representing the only case known to date. Review of Zika situation updates from major international health authorities for country risk classifications shows heterogeneity in ZIKV country travel advisories. Conclusions Travelers are integral to the global spread of ZIKV, serving as sentinel markers of disease activity. Although GeoSentinel data are collected by specialized clinics and do not capture all imported cases, we show that surveillance of imported infections by returned travelers augments local surveillance system data regarding ZIKV epidemiology and can assist with risk categorization by international authorities. However, travel advisories are variable due to risk uncertainties. PMID:28973011

  15. Selective sentinel node biopsy after intratumour administration of radiotracer in breast cancer patients treated with neoadjuvant chemotherapy in relation to the level of tumour response.

    PubMed

    Díaz-Expósito, R; Martí-Bonmatí, L; Burgués, O; Casáns-Tormo, I; Bermejo-de Las Heras, B; Julve-Parreño, A; Caballero-Garate, A

    Our objective was to analyse the accuracy of the sentinel node biopsy, taking into consideration the scintigraphy detection rate after the intratumoural administration of the radiopharmaceutical in patients with breast cancer who received neoadjuvant chemotherapy. The study included 60 patients with a diagnosis of invasive breast carcinoma, stage T1-T3, who received treatment with neoadjuvant chemotherapy, and were subsequently subjected to breast surgery and sentinel node biopsy after intra-tumour administration of the radiopharmaceutical. Scintigraphic detection of some sentinel node was achieved in 55/60 patients (91.6%). When those cases that received a second injection of the radiopharmaceutical, performed peri-areolarly due to a lack of tracer migration, were excluded, the detection rate dropped to 70% (42/60). When the detection of sentinel node, or its absence, was compared in those 42 patients, no differences were found with age, laterality-location of the lesion, size pre- and post-neoadjuvant chemotherapy, histological grade, or immunohistochemical profile. There were significant differences when comparing the groups according to the degree of pathological tumour response, both with the Miller-Payne system (non-detection 44.4%-detection 16.7%, p = 0.003) as well as the residual cancer burden (72.2%-28.6%, p<0.01). The scintigraphic detection of the sentinel node after intratumoural administration of the radiopharmaceutical in patients with breast cancer who received neoadjuvant chemotherapy was below the optimal value, and sometimes a further, peri-areolar, injection was necessary, probably in relation to an alteration in the lymphatic drainage pathways. There was a significant inverse relationship between the detection of the sentinel node and level of pathological tumour response. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. Copernicus POD Service: Orbit Determination of the Sentinel Satellites

    NASA Astrophysics Data System (ADS)

    Peter, Heike; Fernández, Jaime; Ayuga, Francisco; Féménias, Pierre

    2016-04-01

    The Copernicus POD (Precise Orbit Determination) Service is part of the Copernicus Processing Data Ground Segment (PDGS) of the Sentinel-1, -2 and -3 missions. A GMV-led consortium is operating the Copernicus POD Service being in charge of generating precise orbital products and auxiliary data files for their use as part of the processing chains of the respective Sentinel PDGS. Sentinel-1A was launched in April 2014 while Sentinel-2A was on June 2015 and both are routinely operated since then. Sentinel-3A is expected to be launched in February 2016 and Sentinel-1B is planned for spring 2016. Thus the CPOD Service will be operating three to four satellites simultaneously in spring 2016. The satellites of the Sentinel-1, -2, and -3 missions are all equipped with dual frequency high precision GPS receivers delivering the main observables for POD. Sentinel-3 satellites will additionally be equipped with a laser retro reflector for Satellite Laser Ranging and a receiver for DORIS tracking. All three types of observables (GPS, SLR and DORIS) will be used routinely for POD. The POD core of the CPOD Service is NAPEOS (Navigation Package for Earth Orbiting Satellites) the leading ESA/ESOC software for precise orbit determination. The careful selection of models and inputs is important to achieve the different but very demanding requirements in terms of orbital accuracy and timeliness for the Sentinel -1, -2 & -3 missions. The three missions require orbital products with various latencies from 30 minutes up to 20-30 days. The accuracy requirements are also different and partly very challenging, targeting 5 cm in 3D for Sentinel-1 and 2-3 cm in radial direction for Sentinel-3. Although the characteristics and the requirements are different for the three missions the same core POD setup is used to the largest extent possible. This strategy facilitates maintenance of the complex system of the CPOD Service. Updates in the dynamical modelling of the satellite orbits, e

  17. Sentinel-3 SAR Altimetry Toolbox

    NASA Astrophysics Data System (ADS)

    Benveniste, Jerome; Lucas, Bruno; DInardo, Salvatore

    2015-04-01

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage of ERS-2 and Envisat, and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the two Sentinels is expected to be launched in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission's data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as netCDF, ASCII text files, KML (Google Earth

  18. Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience.

    PubMed

    Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan

    2016-01-01

    Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2-3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible.

  19. 78 FR 67168 - Sixth Annual Sentinel Initiative; Public Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-08

    ...] Sixth Annual Sentinel Initiative; Public Workshop AGENCY: Food and Drug Administration, HHS. ACTION... workshop entitled ``Sixth Annual Sentinel Initiative.'' Convened by the Engelberg Center for Health Care... product surveillance. Topics will include an overview of the status of FDA's Sentinel Initiative and...

  20. Human and Animal Sentinels for Shared Health Risks

    PubMed Central

    Rabinowitz, Peter; Scotch, Matthew; Conti, Lisa

    2009-01-01

    Summary The tracking of sentinel health events in humans in order to detect and manage disease risks facing a larger population is a well accepted technique applied to influenza, occupational conditions, and emerging infectious diseases. Similarly, animal health professionals routinely track disease events in sentinel animal colonies and sentinel herds. The use of animals as sentinels for human health threats, or of humans as sentinels for animal disease risk, dates back at least to the era when coal miners brought caged canaries into mines to provide early warning of toxic gases. Yet the full potential of linking animal and human health information to provide warning of such “shared risks” from environmental hazards has not been realized. Reasons appear to include the professional segregation of human and animal health communities, the separation of human and animal surveillance data, and evidence gaps in the linkages between human and animal responses to environmental health hazards. The One Health initiative and growing international collaboration in response to pandemic threats, coupled with development the fields of informatics and genomics, hold promise for improved sharing of knowledge about sentinel events in order to detect and reduce environmental health threats shared between species. PMID:20148187

  1. Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience

    PubMed Central

    Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan

    2016-01-01

    Objective: Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. Material and Methods: IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Results: Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2–3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. Conclusion: According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible. PMID:26985159

  2. Sentinel node detection in pre-operative axillary staging.

    PubMed

    Trifirò, Giuseppe; Viale, Giuseppe; Gentilini, Oreste; Travaini, Laura Lavinia; Paganelli, Giovanni

    2004-06-01

    The concept of sentinel lymph node biopsy in breast cancer surgery is based on the fact that the tumour drains in a logical way via the lymphatic system, from the first to upper levels. Since axillary node dissection does not improve the prognosis of patients with breast cancer, sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Subdermal or peritumoural injection of small aliquots (and very low activity) of radiotracer is preferred to intratumoural administration, and (99m)Tc-labelled colloids with most of the particles in the 100-200 nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. The success rate of radioguidance in localising the sentinel lymph node in breast cancer surgery is about 97% in institutions where a high number of procedures are performed, and the success rate of lymphoscintigraphy in sentinel node detection is about 100%. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when necessary, immune staining with anti-cytokeratin antibody. Nowadays, lymphoscintigraphy is a useful procedure in patients with different clinical evidence of breast cancer.

  3. Operational marine products from Copernicus Sentinel-3 mission

    NASA Astrophysics Data System (ADS)

    Tomazic, Igor; Montagner, Francois; O'Carroll, Anne; Kwiatkowska, Ewa; Scharroo, Remko; Nogueira Loddo, Carolina; Martin-Puig, Cristina; Bonekamp, Hans; Lucas, Bruno; Dinardo, Salvatore; Dash, Prasanjit; Taberner, Malcolm; Coto Cabaleiro, Eva; Santacesaria, Vincenzo; Wilson, Hilary

    2017-04-01

    The first Copernicus Sentinel-3 satellite, Sentinel-3A, was launched in early 2016, with the mission to provide a consistent, long-term collection of marine and land data for operational analysis, forecasting and environmental and climate monitoring. The marine centre is part of the Sentinel-3 Payload Data Ground Segment, located at EUMETSAT. This centre together with the existing EUMETSAT facilities provides a routine centralised service for operational meteorology, oceanography, and other Sentinel-3 marine users as part of the European Commission's Copernicus programme. The EUMETSAT marine centre delivers operational Sea Surface Temperature, Ocean Colour and Sea Surface Topography data products based on the measurements from the Sea and Land Surface Temperature Radiometer (SLSTR), Ocean and Land Colour Instrument (OLCI) and Synthetic Aperture Radar Altimeter (SRAL), respectively, all aboard Sentinel-3. All products have been developed together with ESA and industry partners and EUMETSAT is responsible for the production, distribution, and future evolution of Level-2 marine products. We will give an overview of the scientific characteristics and algorithms of all marine Level-2 products, as well as instrument calibration and product validation results based on on-going Sentinel-3 Cal/Val activities. Information will be also provided about the current status of the product dissemination and the future evolutions that are envisaged. Also, we will provide information how to access Sentinel-3 data from EUMETSAT and where to look for further information.

  4. Breast sentinel lymph node navigation with three-dimensional computed tomography-lymphography: a 12-year study.

    PubMed

    Yamamoto, Shigeru; Suga, Kazuyoshi; Maeda, Kazunari; Maeda, Noriko; Yoshimura, Kiyoshi; Oka, Masaaki

    2016-05-01

    To evaluate the utility of three-dimensional (3D) computed tomography (CT)-lymphography (LG) breast sentinel lymph node navigation in our institute. Between 2002 and 2013, we preoperatively identified sentinel lymph nodes (SLNs) in 576 clinically node-negative breast cancer patients with T1 and T2 breast cancer using 3D CT-LG method. SLN biopsy (SLNB) was performed in 557 of 576 patients using both the images of 3D CT-LG for guidance and the blue dye method. Using 3D CT-LG, SLNs were visualized in 569 (99%) of 576 patients. Of 569 patients, both lymphatic draining ducts and SLNs from the peritumoral and periareolar areas were visualized in 549 (96%) patients. Only SLNs without lymphatic draining ducts were visualized in 20 patients. Drainage lymphatic pathways visualized with 3D CT-LG (549 cases) were classified into four patterns: single route/single SLN (355 cases, 65%), multiple routes/single SLN (59 cases, 11%) single route/multiple SLNs (62 cases, 11%) and multiple routes/multiple SLNs (73 cases, 13%). SLNs were detected in 556 (99.8%) of 557 patients during SLNB. CT-LG is useful for preoperative visualization of SLNs and breast lymphatic draining routes. This preoperative method should contribute greatly to the easy detection of SLNs during SLNB.

  5. The SENTINEL-3 Mission: Overview and Status

    NASA Astrophysics Data System (ADS)

    Benveniste, J.; Mecklenburg, S.

    2015-12-01

    The Copernicus Programme, being Europe's Earth Observation and Monitoring Programme led by the European Union, aims to provide, on a sustainable basis, reliable and timely services related to environmental and security issues. The Sentinel-3 mission forms part of the Copernicus Space Component. Its main objectives, building on the heritage and experience of the European Space Agency's (ESA) ERS and ENVISAT missions, are to measure sea-surface topography, sea- and land-surface temperature and ocean- and land-surface colour in support of ocean forecasting systems, and for environmental and climate monitoring. The series of Sentinel-3 satellites will ensure global, frequent and near-real time ocean, ice and land monitoring, with the provision of observation data in routine, long term (up to 20 years of operations) and continuous fashion, with a consistent quality and a high level of reliability and availability. The Sentinel-3 missions will be jointly operated by ESA and EUMETSAT. ESA will be responsible for the operations, maintenance and evolution of the Sentinel-3 ground segment on land related products and EUMETSAT for the marine products. The Sentinel-3 ground segment systematically acquires, processes and distributes a set of pre-defined core data products. Sentinel-3A is foreseen to be launched at the beginning of November 2015. The paper will give an overview on the mission, its instruments and objectives, the data products provided, the mechanisms to access the mission's data, and if available first results.

  6. Sentinel-3 for Science

    NASA Astrophysics Data System (ADS)

    Benveniste, J.; Regner, P.; Desnos, Y. L.

    2015-12-01

    The Scientific Exploitation of Operational Mission (SEOM) programme element (http://seom.esa.int/) is part of the ESA's Fourth Earth Observation Envelope Programme (2013-2017). The prime objective is to federate, support and expand the international research community that the ERS, ENVISAT and the Envelope programmes have built up over the last 25 years. It aims to further strengthen the leadership of the European Earth Observation research community by enabling them to extensively exploit future European operational EO missions. SEOM is enabling the science community to address new scientific research that are opened by free and open access to data from operational EO missions. The Programme is based on community-wide recommendations for actions on key research issues, gathered through a series of international thematic workshops and scientific user consultation meetings such as the Sentinel-3 for Science Workshop held last June in Venice, Italy (see http://seom.esa.int/S3forScience2015). The 2015 SEOM work plan includes the launch of new R&D studies for scientific exploitation of the Sentinels, the development of open-source multi-mission scientific toolboxes, the organization of advanced international training courses, summer schools and educational materials, as well as activities for promoting the scientific use of EO data, also via the organization of Workshops. This paper will report the recommendations from the International Scientific Community concerning the Sentinel-3 Scientific Exploitation, as expressed in Venice, keeping in mind that Sentinel-3 is an operational mission to provide operational services (see http://www.copernicus.eu).

  7. Anal metastasis as the sentinel and isolated presentation of invasive ductal breast carcinoma.

    PubMed

    Rengifo, C; Titi, S; Walls, J

    2016-05-01

    Breast cancer currently affects 1 in 8 women in the UK during their lifetime. Common sites for breast cancer metastasis include the axillary lymph nodes, bones, lung, liver, brain, soft tissue and adrenal glands. There is well documented evidence detailing breast metastasis to the gastrointestinal tract but anal metastasis is exceptionally rare. We present the case of a 78-year-old woman with an anal metastasis as the sentinel and isolated presentation of an invasive ductal breast carcinoma. As advances in the treatment of breast cancer improve, and with an ageing and expanding population, there will be an increasing number of cancer survivors, and more of these unusual presentations may be encountered in the future.

  8. Effects of peatland drainage on water quality: a case study of the shallow blanket bogs of Exmoor, UK

    NASA Astrophysics Data System (ADS)

    Grand-Clement, E.; Luscombe, D.; Le Feuvre, N.; Smith, D.; Anderson, K.; Brazier, R. E.

    2012-04-01

    Peatlands are widely represented in the South West of England (i.e. Exmoor, Dartmoor and Bodmin moors), but their existence is currently under threat due to both climate change and the impact of historical human activities. Peat cutting and intensive drainage for agricultural reclamation in the 19th and 20th century, have modified the hydrological behaviour of these shallow peats and dried out the upper layers, causing oxidation, erosion and vegetation change. Such anthropogenic impacts directly affect the storage of carbon, but also the provision of other ecosystem services, such as the supply of drinking water, and the support of specific and rare habitats. Blocking drainage ditches to restore the hydrological behaviour of peatlands has mostly been undertaken in the North of England, but to date, little is still known about the consequences of such management approaches on the overall Carbon stocks. The need to monitor restoration of peatlands in the South West of England arises due to the specific characteristics of the peat - it is often shallower than more northerly peat and dominated by Purple Moor Grass. In addition, and in part because of the shallowness of the resource, the peat has been damaged differently, often with very dense networks of hand-cut ditches which behave as highly efficient drainage networks. Most importantly, their location at the southernmost margin of the UK peatlands' geographical extent makes them extremely vulnerable to climate change, and so it is hypothesised that monitoring of these peatlands may provide an 'early warning system' for climatic impacts that affect more northerly sites in years to come. This study focuses upon the current impact of peatland degradation on water quality on Exmoor. Our experimental approach employs detailed, high resolution monitoring of selected ditches that are representative of damaged conditions on Exmoor, from small- (30 x 30cm ditches) through medium- (50x50cm), large- (1-2m ditches) and finally

  9. Sentinel 2 global reference image

    NASA Astrophysics Data System (ADS)

    Dechoz, C.; Poulain, V.; Massera, S.; Languille, F.; Greslou, D.; de Lussy, F.; Gaudel, A.; L'Helguen, C.; Picard, C.; Trémas, T.

    2015-10-01

    Sentinel-2 is a multispectral, high-resolution, optical imaging mission, developed by the European Space Agency (ESA) in the frame of the Copernicus program of the European Commission. In cooperation with ESA, the Centre National d'Etudes Spatiales (CNES) is responsible for the image quality of the project, and will ensure the CAL/VAL commissioning phase. Sentinel-2 mission is devoted the operational monitoring of land and coastal areas, and will provide a continuity of SPOT- and Landsat-type data. Sentinel-2 will also deliver information for emergency services. Launched in 2015 and 2016, there will be a constellation of 2 satellites on a polar sun-synchronous orbit, imaging systematically terrestrial surfaces with a revisit time of 5 days, in 13 spectral bands in visible and shortwave infra-red. Therefore, multi-temporal series of images, taken under the same viewing conditions, will be available. So as to ensure for the multi-temporal registration of the products, specified to be better than 0.3 pixels at 2σ, a Global Reference Image (GRI) will be produced during the CAL/VAL period. This GRI is composed of a set of Sentinel-2 acquisitions, which geometry has been corrected by bundle block adjustment. During L1B processing, Ground Control Points will be taken between this reference image and the sentinel-2 acquisition processed and the geometric model of the image corrected, so as to ensure the good multi-temporal registration. This paper first details the production of the reference during the CALVAL period, and then details the qualification and geolocation performance assessment of the GRI. It finally presents its use in the Level-1 processing chain and gives a first assessment of the multi-temporal registration.

  10. Anatomical classification of breast sentinel lymph nodes using computed tomography-lymphography.

    PubMed

    Fujita, Tamaki; Miura, Hiroyuki; Seino, Hiroko; Ono, Shuichi; Nishi, Takashi; Nishimura, Akimasa; Hakamada, Kenichi; Aoki, Masahiko

    2018-05-03

    To evaluate the anatomical classification and location of breast sentinel lymph nodes, preoperative computed tomography-lymphography examinations were retrospectively reviewed for sentinel lymph nodes in 464 cases clinically diagnosed with node-negative breast cancer between July 2007 and June 2016. Anatomical classification was performed based on the numbers of lymphatic routes and sentinel lymph nodes, the flow direction of lymphatic routes, and the location of sentinel lymph nodes. Of the 464 cases reviewed, anatomical classification could be performed in 434 (93.5 %). The largest number of cases showed single route/single sentinel lymph node (n = 296, 68.2 %), followed by multiple routes/multiple sentinel lymph nodes (n = 59, 13.6 %), single route/multiple sentinel lymph nodes (n = 53, 12.2 %), and multiple routes/single sentinel lymph node (n = 26, 6.0 %). Classification based on the flow direction of lymphatic routes showed that 429 cases (98.8 %) had outward flow on the superficial fascia toward axillary lymph nodes, whereas classification based on the height of sentinel lymph nodes showed that 323 cases (74.4 %) belonged to the upper pectoral group of axillary lymph nodes. There was wide variation in the number of lymphatic routes and their branching patterns and in the number, location, and direction of flow of sentinel lymph nodes. It is clinically very important to preoperatively understand the anatomical morphology of lymphatic routes and sentinel lymph nodes for optimal treatment of breast cancer, and computed tomography-lymphography is suitable for this purpose.

  11. GeoSentinel: the global emerging infections sentinel network of the International Society of Travel Medicine.

    PubMed

    Freedman, D O; Kozarsky, P E; Weld, L H; Cetron, M S

    1999-06-01

    GeoSentinel is a network of 22 member travel/tropical medicine clinics (14 in the United States and 8 in other countries) initiated in 1995 by the International Society of Travel Medicine (ISTM). GeoSentinel is based on the concept that these clinics are ideally situated to effectively detect geographic and temporal trends in morbidity among travelers. The core surveillance tool is a single-page faxable form submitted to a central data site for each post-travel patient, including immigrants, refugees, and foreign visitors. Diagnoses are entered either as specific etiologies or as syndromes and are then linked to geographic locations, reference dates, and clinical presentations. In addition, electronic communication with the larger body of worldwide ISTM member clinics is periodically done to obtain broader data collection in response to specific inquiries. The scope of GeoSentinel has broadened from the initial vision of a provider-based sentinel network tracking emerging infections at their point of entry into developed countries. Its present goals are (1) to monitor global trends in disease occurrence among travelers; (2) to ascertain risk factors and morbidity in groups of travelers categorized by travel purpose and type of traveler; (3) to respond to urgent public health queries; (4) to develop educational priorities for travelers' health; and (5) to effect a rapid response by electronically disseminating alerts to surveillance sites, to all ISTM members in 55 countries, and to public health authorities. In addition, a major byproduct of the network, and now one of its strongest assets, has been the growth of partnerships between ISTM, Centers for Disease Control and Prevention and health-care providers around the world, as well as other medical societies, government, and private organizations. The demographic data, travel patterns, and clinical presentations for the first 2813 patient records analyzed from the GeoSentinel sites are summarized in this paper.

  12. Sentinel lymph node detection in patients with endometrial cancer.

    PubMed

    Niikura, Hitoshi; Okamura, Chikako; Utsunomiya, Hiroki; Yoshinaga, Kosuke; Akahira, Junichi; Ito, Kiyoshi; Yaegashi, Nobuo

    2004-02-01

    The purpose of this study was to examine the feasibility of sentinel lymph node (SLN) detection in patients with endometrial cancer using preoperative lymphoscintigraphy and an intraoperative gamma probe. Between June 2001 and January 2003, 28 consecutive patients with endometrial cancer who were scheduled for total abdominal hysterectomy, bilateral salpingo-oophorectomy, total pelvic lymphadenectomy, and paraaortic lymphadenectomy at Tohoku University School of Medicine underwent sentinel lymph node detection. On the day before surgery, preoperative lymphoscintigraphy was performed by injection of 99m-Technetium ((99m)Tc)-labeled phytate into the endometrium during hysteroscopy. At the time of surgery, a gamma-detecting probe was used to locate radioactive lymph nodes. At least one sentinel node was detected in each of 23 of the 28 patients (82%). The mean number of sentinel nodes detected was 3.1 (range, 1-9). Sentinel nodes could be identified in 21 of 22 patients (95%) whose tumor did not invade more than halfway into the myometrium. Eighteen patients had radioactive nodes in the paraaortic area. Most patients had a sentinel node in one of the following three sites: paraaortic, external iliac, and obturator. The sensitivity and specificity for detecting lymph node metastases were both 100%. The combination of preoperative lymphoscintigraphy with intraoperative gamma probe detection may be useful in identifying sentinel nodes in early-stage endometrial cancer.

  13. Sentinel Node and Ovarian Tumors: A Series of 20 Patients.

    PubMed

    Nyberg, Reita H; Korkola, Pasi; Mäenpää, Johanna U

    2017-05-01

    Intraoperative detection of ovarian sentinel nodes has been shown to be feasible. We examined the detection rate and locations of sentinel nodes in patients with ovarian tumors. We also aimed to assess the reliability of sentinel node method in predicting regional lymph node metastasis. Twenty patients scheduled for laparotomy because of a pelvic mass were recruited to the study. In the beginning of the laparotomy, radioisotope and blue dye were injected under the serosa next to the junction of the ovarian tumor and suspensory ligament. The number and locations of the hot and/or blue nodes/spots were recorded during the operation. If the tumor was malignant according to the frozen section, systematic lymphadenectomies were performed, the sentinel nodes sampled separately, and their status compared with other regional lymph nodes. Eleven patients had a right-sided ovarian tumor, 7 patients a left-sided tumor, and 2 patients had bilateral tumors. A median of 2 sentinel nodes/locations per patient (range, 1-3) were found. Sixty percent of all sentinel nodes were located in the para-aortic region only, compared with 30% in both para-aortic and pelvic areas and 10% in pelvic area only. Both unilateral and bilateral locations were found. In 83% of the cases with more than 1 sentinel node location, they were located in separate anatomical regions. In 3 patients, systematic lymphadenectomies were performed. One of them had nodal metastases in 2 regions and also a metastasis in 1 of her 2 sentinel nodes in 1 of those regions. In patients with ovarian tumor(s), the detection of sentinel nodes is feasible. They are located in different anatomic areas both ipsilaterally and contralaterally, although most of them are found in the para-aortic region. The reliability of the sentinel node concept should be evaluated in the framework of a multicenter trial.

  14. Synergy between Sentinel-1 radar time series and Sentinel-2 optical for the mapping of restored areas in Danube delta

    NASA Astrophysics Data System (ADS)

    Niculescu, Simona; Lardeux, Cédric; Hanganu, Jenica

    2018-05-01

    Wetlands are important and valuable ecosystems, yet, since 1900, more than 50 % of wetlands have been lost worldwide. An example of altered and partially restored coastal wetlands is the Danube Delta in Romania. Over time, human intervention has manifested itself in more than a quarter of the entire Danube surface. This intervention was brutal and has rendered ecosystem restoration very difficult. Studies for the rehabilitation / re-vegetation were started immediately after the Danube Delta was declared as a Biosphere Reservation in 1990. Remote sensing offers accurate methods for detecting and mapping change in restored wetlands. Vegetation change detection is a powerful indicator of restoration success. The restoration projects use vegetative cover as an important indicator of restoration success. To follow the evolution of the vegetation cover of the restored areas, satellite images radar and optical of last generation have been used, such as Sentinel-1 and Sentinel-2. Indeed the sensor sensitivity to the landscape depends on the wavelength what- ever radar or optical data and their polarization for radar data. Combining this kind of data is particularly relevant for the classification of wetland vegetation, which are associated with the density and size of the vegetation. In addition, the high temporal acquisition frequency of Sentinel-1 which are not sensitive to cloud cover al- low to use temporal signature of the different land cover. Thus we analyse the polarimetric and temporal signature of Sentinel-1 data in order to better understand the signature of the different study classes. In a second phase, we performed classifications based on the Random Forest supervised classification algorithm involving the entire Sentinel-1 time series, then starting from a Sentinel-2 collection and finally involving combinations of Sentinel-1 and -2 data.

  15. Utilization and Outcomes of Sentinel Lymph Node Biopsy for Vulvar Cancer.

    PubMed

    Cham, Stephanie; Chen, Ling; Burke, William M; Hou, June Y; Tergas, Ana I; Hu, Jim C; Ananth, Cande V; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2016-10-01

    To examine the use and predictors of sentinel node biopsy in women with vulvar cancer. The Perspective database, an all-payer database that collects data from more than 500 hospitals, was used to perform a retrospective cohort study of women with vulvar cancer who underwent vulvectomy and lymph node assessment from 2006 to 2015. Multivariable models were used to determine factors associated with sentinel node biopsy. Length of stay and cost were compared between women who underwent sentinel node biopsy and lymphadenectomy. Among 2,273 women, sentinel node biopsy was utilized in 618 (27.2%) and 1,655 (72.8%) underwent inguinofemoral lymphadenectomy. Performance of sentinel node biopsy increased from 17.0% (95% confidence interval [CI] 12.0-22.0%) in 2006 to 39.1% (95% CI 27.1-51.0%) in 2015. In a multivariable model, women treated more recently were more likely to have undergone sentinel node biopsy, whereas women with more comorbidities and those treated at rural hospitals were less likely to have undergone the procedure. The median length of stay was shorter for those undergoing sentinel node biopsy (median 2 days, interquartile range 1-3) compared with women who underwent inguinofemoral lymphadenectomy (median 3 days, interquartile range 2-4). The cost of sentinel node biopsy was $7,599 (interquartile range $5,739-9,922) compared with $8,095 (interquartile range $5,917-11,281) for lymphadenectomy. The use of sentinel node biopsy for vulvar cancer has more than doubled since 2006. Sentinel lymph node biopsy is associated with a shorter hospital stay and decreased cost compared with inguinofemoral lymphadenectomy.

  16. CTC Sentinel. Volume 10, Issue 3

    DTIC Science & Technology

    2017-03-01

    Mining Matthew C . DuPée MARCH 2017 C TC SENTINEL 1 Among the most recent evolutions of jihadi terrorist tactics in the West has been...arrest him. Soofi and Simpson committed the attack with assistance from Adbul Malik Abdul Kareem. Source: court documents. c They are Avin Brown (2014...State’s Virtual Entrepreneurs By Seamus Hughes and Alexander Meleagrou-Hitchens 2 C TC SENTINEL MARCH 2017 jihadi propaganda. Together

  17. Improved Survival in Male Melanoma Patients in the Era of Sentinel Node Biopsy.

    PubMed

    Koskivuo, I; Vihinen, P; Mäki, M; Talve, L; Vahlberg, T; Suominen, E

    2017-03-01

    Sentinel node biopsy is a standard method for nodal staging in patients with clinically localized cutaneous melanoma, but the survival advantage of sentinel node biopsy remains unsolved. The aim of this case-control study was to investigate the survival benefit of sentinel node biopsy. A total of 305 prospective melanoma patients undergoing sentinel node biopsy were compared with 616 retrospective control patients with clinically localized melanoma whom have not undergone sentinel node biopsy. Survival differences were calculated with the median follow-up time of 71 months in sentinel node biopsy patients and 74 months in control patients. Analyses were calculated overall and separately in males and females. Overall, there were no differences in relapse-free survival or cancer-specific survival between sentinel node biopsy patients and control patients. Male sentinel node biopsy patients had significantly higher relapse-free survival ( P = 0.021) and cancer-specific survival ( P = 0.024) than control patients. In females, no differences were found. Cancer-specific survival rates at 5 years were 87.8% in sentinel node biopsy patients and 85.2% in controls overall with 88.3% in male sentinel node biopsy patients and 80.6% in male controls and 87.3% in female sentinel node biopsy patients and 89.8% in female controls. Sentinel node biopsy did not improve survival in melanoma patients overall. While females had no differences in survival, males had significantly improved relapse-free survival and cancer-specific survival following sentinel node biopsy.

  18. Overview of Sentinel-2

    NASA Astrophysics Data System (ADS)

    Fernandez, Valerie; Martimort, Philippe; Spoto, Francois; Sy, Omar; Laberinti, Paolo

    2013-10-01

    GMES is a joint initiative of the European Commission (EC) and the European Space Agency (ESA), designed to establish a European capacity for the provision and use of operational monitoring information for environment and security applications. ESA's role in GMES is to provide the definition and the development of the space- and ground-related system elements. GMES Sentinel-2 mission provides continuity to services relying on multi-spectral highresolution optical observations over global terrestrial surfaces. The key mission objectives for Sentinel-2 are: (1) to provide systematic global acquisitions of high-resolution multi-spectral imagery with a high revisit frequency, (2) to provide enhanced continuity of multi-spectral imagery provided by the SPOT series of satellites, and (3) to provide observations for the next generation of operational products such as landcover maps, land change detection maps, and geophysical variables. Consequently, Sentinel-2 will directly contribute to the Land Monitoring, Emergency Response, and Security services. The corresponding user requirements have driven the design towards a dependable multi-spectral Earthobservation system featuring the MSI with 13 spectral bands spanning from the visible and the near infrared to the short wave infrared. The spatial resolution varies from 10 m to 60 m depending on the spectral band with a 290 km field of view. This unique combination of high spatial resolution, wide field of view and large spectral coverage will represent a major step forward compared to current multi-spectral missions. The mission foresees a series of satellites, each having a 7.25-year lifetime (extendable to 12 years) over a 20-year period starting with the launch of Sentinel-2A foreseen by mid-2014. During full operations two identical satellites will be maintained in the same sun synchronous orbit with a phase delay of 180° providing a revisit time of five days at the equator.

  19. Sentinel-2 radiometric image quality commissioning: first results

    NASA Astrophysics Data System (ADS)

    Lachérade, S.; Lonjou, V.; Farges, M.; Gamet, P.; Marcq, S.; Raynaud, J.-L.; Trémas, T.

    2015-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. Sentinel-2 offers a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high spatial resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infrared domains). The first satellite, Sentinel-2A, has been launched in June 2015. The Sentinel-2A Commissioning Phase starts immediately after the Launch and Early Orbit Phase and continues until the In-Orbit Commissioning Review which is planned three months after the launch. The Centre National d'Etudes Spatiales (CNES) supports ESA/ESTEC to insure the Calibration/Validation commissioning phase during the first three months in flight. This paper provides first an overview of the Sentinel-2 system and a description of the products delivered by the ground segment associated to the main radiometric specifications to achieve. Then the paper focuses on the preliminary radiometric results obtained during the in-flight commissioning phase. The radiometric methods and calibration sites used in the CNES image quality center to reach the specifications of the sensor are described. A status of the Sentinel-2A radiometric performances at the end of the first three months after the launch is presented. We will particularly address in this paper the results in term of absolute calibration, pixel to pixel relative sensitivity and MTF estimation.

  20. Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    PubMed Central

    Vermeeren, L.; Klop, W. M. C.; van den Brekel, M. W. M.; Balm, A. J. M.; Nieweg, O. E.; Valdés Olmos, R. A.

    2009-01-01

    Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described. PMID:20016804

  1. Sentinel Node Biopsy in Melanoma: A Short Update

    PubMed Central

    Ferrara, Gerardo; Partenzi, Antonietta; Filosa, Alessandra

    2018-01-01

    Several controversies are still ongoing about sentinel node biopsy in melanoma. It is basically a staging procedure for melanoma > 0.75 mm in thickness or for thinner melanoma in the presence of ulceration, high mitotic rate, and/or lymphovascular invasion. Complete lymph node dissection after a positive sentinel node can also allow a better locoregional disease control but seems not to prevent the development of distant metastases. The use of sentinel node biopsy in atypical Spitz tumors should be discouraged because of their peculiar biological properties. PMID:29719827

  2. Use of sentinel mallards for epizootiologic studies of avian botulism

    USGS Publications Warehouse

    Rocke, T.E.; Brand, C.J.

    1994-01-01

    Captive-reared mallards (Anas platyrhynchos) were used as sentinels to study the epizootiology of avian botulism at the Sacramento National Wildlife Refuge, Willows, California (USA) from 1986 to 1989. Sentinel mallards were wing-clipped, and 40 to 50 birds were confined in 1.6-ha enclosures in 11 selected wetlands (pools). Enclosures were searched intensively three to four times weekly from July through October. Sick and dead wild and sentinel birds were collected, necropsied, and tested for type C botulism toxin. Botulism epizootics occurred in sentinel mallards in 1986, 1987, and 1989, but only a few isolated cases of botulism were detected in 1988. In most epizootics, botulism also was detected simultaneously in wild birds using the same pool outside the enclosure. Epizootics in sentinels were initiated and perpetuated in the absence of vertebrate carcasses. A sex-specific trend in the probability of intoxication was detected, with males contracting botulism at a higher rate than females. Daily mortality rates of sentinels during botulism epizootics ranged from 0.0006 to 0.0600, with a mean of 0.0190. These rates would result in the daily loss of 0.6 to 60 birds per thousand at risk. The use of sentinel birds provided an effective means of gathering site-specific epizootiologic data.

  3. Getting ready for the arrival of Sentinel data

    NASA Astrophysics Data System (ADS)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2013-04-01

    The European Union (EU) and the European Space Agency (ESA) have developed the Global Monitoring for Environment and Security (GMES), being renamed to Copernicus, programme as Europe's answer to the vital need for joined-up data about our climate, environment and security. Through a unique combination of satellite, atmospheric and Earth-based monitoring systems, the initiative will provide new insight into the state of the land, sea and air, providing policymakers, scientists, businesses and the public with accurate and timely information. GMES capabilities include monitoring and forecasting of climatic change, flood risks, soil and coastal erosion, crop and fish resources, air pollution, greenhouse gases, iceberg distribution and snow cover, among others. To accomplish this, GMES has been divided into three main components: Space, In-situ and Services. The Space Component, led by ESA, comprises five types of new dedicated satellites called Sentinels. These missions carry a range of technologies, such as radar and multi-spectral imaging instruments for land, ocean and atmospheric monitoring. While the Sentinel satellites are currently being developed by ESA specifically to meet the needs of GMES, the Contributing Missions, operated by national agencies or commercial entities, are already providing a wealth of data for GMES services, and will continue to deliver complementary data after the Sentinels are in orbit. An integrated Ground Segment ensures access to Sentinels and Contributing Missions data. Access to Sentinel data is governed by the Sentinel data policy, which is part of a wider GMES data and information access policy. The Sentinel data policy envisages free and open access, subject to restrictions only if security or other European interests need to be preserved. As regards the Contributing Missions, the data policy of the mission owners will be respected for the purpose of providing data to GMES service users. The first in the fleet of dedicated

  4. Black sentinel lymph node and 'scary stickers'.

    PubMed

    Yang, Arthur S; Creagh, Terrence A

    2013-04-01

    An unusual case is presented of a young adult patient with two black-stained, radio-nucleotide tracer-active sentinel lymph nodes biopsied following her primary cutaneous melanoma treatment. This was subsequently confirmed to be secondary to cutaneous tattoos, averting the need of an elective regional node dissection. History of tattooing and tattoo removal should therefore be obtained as a routine in all melanoma patients considered for sentinel node biopsy (SLN). SLN biopsy and any subsequent completion node dissection should be strictly staged so that proper histologic diagnosis of the sentinel node is available for correct decision making and treatment. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Sentinel node localization in oral cavity and oropharynx squamous cell cancer.

    PubMed

    Taylor, R J; Wahl, R L; Sharma, P K; Bradford, C R; Terrell, J E; Teknos, T N; Heard, E M; Wolf, G T; Chepeha, D B

    2001-08-01

    To evaluate the feasibility and predictive ability of the sentinel node localization technique for patients with squamous cell carcinoma of the oral cavity or oropharynx and clinically negative necks. Prospective, efficacy study comparing the histopathologic status of the sentinel node with that of the remaining neck dissection specimen. Tertiary referral center. Patients with T1 or T2 disease and clinically negative necks were eligible for the study. Nine previously untreated patients with oral cavity or oropharyngeal squamous cell carcinoma were enrolled in the study. Unfiltered technetium Tc 99m sulfur colloid injections of the primary tumor and lymphoscintigraphy were performed on the day before surgery. Intraoperatively, the sentinel node(s) was localized with a gamma probe and removed after tumor resection and before neck dissection. The primary outcome was the negative predictive value of the histopathologic status of the sentinel node for predicting cervical metastases. Sentinel nodes were identified in 9 previously untreated patients. In 5 patients, there were no positive nodes. In 4 patients, the sentinel nodes were the only histopathologically positive nodes. In previously untreated patients, the sentinel node technique had a negative predictive value of 100% for cervical metastasis. Our preliminary investigation shows that sentinel node localization is technically feasible in head and neck surgery and is predictive of cervical metastasis. The sentinel node technique has the potential to decrease the number of neck dissections performed in clinically negative necks, thus reducing the associated morbidity for patients in this group.

  6. Contribution of the new satellites (Sentinel-1, Sentinel-2 and SPOT-6) to the coastal vegetation monitoring in the Pays de Brest (France)

    NASA Astrophysics Data System (ADS)

    Talab-Ou-Ali, Halima; Niculescu, Simona; Sellin, Vanessa; Bougault, Christophe

    2017-10-01

    This paper presents a methodology for monitoring vegetation in the Pays de Brest using new series of Sentinel-1 satellite images combining with Sentinel-2 and SPOT-6. This work consists of establishing an interferogram method of the main types of vegetation in order to achieve the coherence of a multi-temporal Sentinel-1 radar image series, in SLC format (C band, VV and VH polarization), between 2015 and 2016. We then proceed to calculating the radar backscatter coefficient based on Sentinel 1 images in GRD format. Multi-date and multipolarized color compositions will be made to detect changes. It also shows the importance of data synergy to obtain an excellent accuracy using Random Forest classification.

  7. [The historical perspective of the sentinel lymph node concept].

    PubMed

    Bekker, J; Meijer, S

    2008-01-05

    The sentinel lymph node procedure is currently standard care in the treatment of breast cancer. The introduction of this procedure in 1992 would not have been possible without the pioneering discoveries regarding lymph nodes and cancer. The Italian surgeon Gaspar Asellius (1581-1626) visualized the lymphatic vessels of a dog after it had been fed and shortly before dissection. At the end of the 17th century, the French anatomists Lauth and Sappey visualized the lymphatics by injecting deceased criminals with mercury. In 1858, the German pathologist Virchow (1821-1902) launched the theory that lymph nodes act as defensive barriers. He also made the first microscopical illustration ofa sentinel lymph node. Gould et al. and Cabaãs independently launched the precursors of the current modern sentinel lymph node concept in 1959 and 1977 respectively. Gould et al. were the first people to use the term "sentinel node'. Cabañas used lymphangiography for the visualisation of the sentinel lymph node. Controversies about the barrier function of the lymph nodes, the fear of skip metastasis and the difficulties of performing the Cabañas procedure, prevented a breakthrough of this concept. In 1992 Morton et al. rediscovered the valuable sentinel node biopsy concept and introduced blue dye for the investigation of patients with melanoma. The combination of lymphoscintigraphy, intra-operative gamma probe guidance and patent blue further increased the reliability of the sentinel lymph node biopsy procedure. Unnecessary lymph gland dissection procedures with considerable morbidity can be prevented by this procedure.

  8. A mathematical prediction model incorporating molecular subtype for risk of non-sentinel lymph node metastasis in sentinel lymph node-positive breast cancer patients: a retrospective analysis and nomogram development.

    PubMed

    Wang, Na-Na; Yang, Zheng-Jun; Wang, Xue; Chen, Li-Xuan; Zhao, Hong-Meng; Cao, Wen-Feng; Zhang, Bin

    2018-04-25

    Molecular subtype of breast cancer is associated with sentinel lymph node status. We sought to establish a mathematical prediction model that included breast cancer molecular subtype for risk of positive non-sentinel lymph nodes in breast cancer patients with sentinel lymph node metastasis and further validate the model in a separate validation cohort. We reviewed the clinicopathologic data of breast cancer patients with sentinel lymph node metastasis who underwent axillary lymph node dissection between June 16, 2014 and November 16, 2017 at our hospital. Sentinel lymph node biopsy was performed and patients with pathologically proven sentinel lymph node metastasis underwent axillary lymph node dissection. Independent risks for non-sentinel lymph node metastasis were assessed in a training cohort by multivariate analysis and incorporated into a mathematical prediction model. The model was further validated in a separate validation cohort, and a nomogram was developed and evaluated for diagnostic performance in predicting the risk of non-sentinel lymph node metastasis. Moreover, we assessed the performance of five different models in predicting non-sentinel lymph node metastasis in training cohort. Totally, 495 cases were eligible for the study, including 291 patients in the training cohort and 204 in the validation cohort. Non-sentinel lymph node metastasis was observed in 33.3% (97/291) patients in the training cohort. The AUC of MSKCC, Tenon, MDA, Ljubljana, and Louisville models in training cohort were 0.7613, 0.7142, 0.7076, 0.7483, and 0.671, respectively. Multivariate regression analysis indicated that tumor size (OR = 1.439; 95% CI 1.025-2.021; P = 0.036), sentinel lymph node macro-metastasis versus micro-metastasis (OR = 5.063; 95% CI 1.111-23.074; P = 0.036), the number of positive sentinel lymph nodes (OR = 2.583, 95% CI 1.714-3.892; P < 0.001), and the number of negative sentinel lymph nodes (OR = 0.686, 95% CI 0

  9. ESA Sentinel-1 Mission and Products

    NASA Astrophysics Data System (ADS)

    Floury, Nicolas; Attema, Evert; Davidson, Malcolm; Levrini, Guido; Rommen, Björn; Rosich, Betlem; Snoeij, Paul

    The global Monitoring for Environment and Security (GMES) space component relies on existing and planned space assets by European States, the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT), and the European Space Agency (ESA), as well as new complementary developments by ESA. The new developments are implemented in terms of five families of satellites called Sentinels. The Sentinel-1 mission is an imaging synthetic aperture radar (SAR) mission at C-band designed to supply all-weather day-and-night imagery to a number of operational Earth observation based services. Three priorities (fasttrack services) for the mission have been identified by user consultation working groups of the European Union: Marine Core Services, Land Monitoring and Emergency Services. These cover applications such as: - monitoring sea ice zones and the arctic environment, - surveillance of marine environment, - monitoring land surface motion risks, - mapping of land surfaces: forest, water and soil, agriculture, - mapping in support of humanitarian aid in crisis situations. Sentinel-1 has been designed to address medium resolution applications. It includes a main mode of operation that features a wide swath (250 km) and a medium resolution (5 m x 20 m). The two-satellite constellation offers six days exact repeat and the conflict-free operations based on the main operational mode allow exploiting every single data take. This paper describes the Sentinel-1 mission, provides an overview of the mission requirements, and presents some of the key user driven information products, the crucial requirements for operational sustainable services being continuity of data supply, frequent revisit, geographical coverage and timeliness. As data products from the Agency‘s successful ERS-1, ERS-2 and Envisat missions form the basis for many of the pilot GMES services, Sentinel-1 data products need to maintain and in some ways to improve data quality levels of the Agency

  10. Forest Area Derivation from SENTINEL-1 Data

    NASA Astrophysics Data System (ADS)

    Dostálová, Alena; Hollaus, Markus; Milenković, Milutin; Wagner, Wolfgang

    2016-06-01

    The recently launched Sentinel-1A provides the high resolution Synthetic Aperture Radar (SAR) data with very high temporal coverage over large parts of European continent. Short revisit time and dual polarization availability supports its usability for forestry applications. The following study presents an analysis of the potential of the multi-temporal dual-polarization Sentinel-1A data for the forest area derivation using the standard methods based on Otsu thresholding and K-means clustering. Sentinel-1 data collected in winter season 2014-2015 over a test area in eastern Austria were used to derive forest area mask with spatial resolution of 10m and minimum mapping unit of 500 m2. The validation with reference forest mask derived from airborne full-waveform laser scanning data revealed overall accuracy of 92 % and kappa statistics of 0.81. Even better results can be achieved when using external mask for urban areas, which might be misclassified as forests when using the introduced approach based on SAR data only. The Sentinel-1 data and the described methods are well suited for forest change detection between consecutive years.

  11. Indocyanine green SPY elite-assisted sentinel lymph node biopsy in cutaneous melanoma.

    PubMed

    Korn, Jason M; Tellez-Diaz, Alejandra; Bartz-Kurycki, Marisa; Gastman, Brian

    2014-04-01

    Sentinel lymph node biopsy is the standard of care for intermediate-depth and high-risk thin melanomas. Recently, indocyanine green and near-infrared imaging have been used to aid in sentinel node biopsy. The present study aimed to determine the feasibility of sentinel lymph node biopsy with indocyanine green SPY Elite navigation and to critically evaluate the technique compared with the standard modalities. A retrospective review of 90 consecutive cutaneous melanoma patients who underwent sentinel lymph node biopsy was performed. Two cohorts were formed: group A, which had sentinel lymph node biopsy performed with blue dye and radioisotope; and group B, which had sentinel lymph node biopsy performed with radioisotope and indocyanine green SPY Elite navigation. The cohorts were compared to assess for differences in localization rates, sensitivity and specificity of sentinel node identification, and length of surgery. The sentinel lymph node localization rate was 79.4 percent using the blue dye method, 98.0 percent using the indocyanine green fluorescence method, and 97.8 percent using the radioisotope/handheld gamma probe method. Indocyanine green fluorescence detected more sentinel lymph nodes than the vital dye method alone (p = 0.020). A trend toward a reduction in length of surgery was noted in the SPY Elite cohort. Sentinel lymph node mapping and localization in cutaneous melanoma with the indocyanine green SPY Elite navigation system is technically feasible and may offer several advantages over current modalities, including higher sensitivity and specificity, decreased number of lymph nodes sampled, decreased operative time, and potentially lower false-negative rates. Diagnostic, II.

  12. CTC Sentinel. Volume 9, Issue 8

    DTIC Science & Technology

    2016-08-01

    607 Cullum Road, Lincoln Hall West Point, NY 10996 Phone: (845) 938-8495 Email: sentinel@usma.edu Web : www.ctc.usma.edu/sentinel/ SUBSMISSIONS...Hallberg Tønnes- sen, “The Islamic Emirate of Fallujah,” paper presented at ISA conference, Montreal, March 16-19, 2011. See also Ben Hubbard, “Iraq...It’s difficult, therefore, to dry up the financing to a point where the money isn’t there to sponsor it. What we do set as our goal is to weaken the

  13. Soil moisture retrieval from Sentinel-1 satellite data

    NASA Astrophysics Data System (ADS)

    Benninga, Harm-Jan; van der Velde, Rogier; Su, Zhongbo

    2016-04-01

    Reliable up-to-date information on the current water availability and models to evaluate management scenarios are indispensable for skilful water management. The Sentinel-1 radar satellite programme provides an opportunity to monitor water availability (as surface soil moisture) from space on an operational basis at unprecedented fine spatial and temporal resolutions. However, the influences of soil roughness and vegetation cover complicate the retrieval of soil moisture states from radar data. In this contribution, we investigate the sensitivity of Sentinel-1 radar backscatter to soil moisture states and vegetation conditions. The analyses are based on 105 Sentinel-1 images in the period from October 2014 to January 2016 covering the Twente region in the Netherlands. This area is almost flat and has a heterogeneous landscape, including agricultural (mainly grass, cereal and corn), forested and urban land covers. In-situ measurements at 5 cm depth collected from the Twente soil moisture monitoring network are used as reference. This network consists of twenty measurement stations (most of them at agricultural fields) distributed across an area of 50 km × 40 km. The Normalized Difference Vegetation Index (NDVI) derived from optical images is adopted as proxy to represent seasonal variability in vegetation conditions. The results from this sensitivity study provide insight into the potential capability of Sentinel-1 data for the estimation of soil moisture states and they will facilitate the further development of operational retrieval methods. An operationally applicable soil moisture retrieval method requires an algorithm that is usable without the need for area specific model calibration with detailed field information (regarding roughness and vegetation). Because it is not yet clear which method provides the most reliable soil moisture retrievals from Sentinel-1 data, multiple soil moisture retrieval methods will be studied in which the fine spatiotemporal

  14. Sentinel node detection in cervical cancer with (99m)Tc-phytate.

    PubMed

    Silva, Lucas B; Silva-Filho, Agnaldo L; Traiman, Paulo; Triginelli, Sérgio A; de Lima, Carla Flávia; Siqueira, Cristiano Ferrari; Barroso, Adelanir; Rossi, Telma Maria F F; Pedrosa, Moises Salgado; Miranda, Dairton; Melo, José Renan Cunha

    2005-05-01

    The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92

  15. Proposed concept and preliminary design for the sentinel-5 UVNs spectrometer

    NASA Astrophysics Data System (ADS)

    Windpassinger, R.; Schubert, J.; Kampf, D.

    2017-11-01

    Sentinel-5 is an atmospheric monitoring mission within the European Copernicus programme, formerly GMES (Global Monitoring for Environment and Security). Its main objective is trace-gas and aerosol optical depth measurements for air quality and climate monitoring and forecast with daily global coverage. Constituents of interest are O3, SO2, HCHO (formaldehyde), BrO, NO2, CHCHO (glyoxal), O2, CH4 (methane), and CO. Sentinel-5 will complement the Sentinel-4 GEO data over Europe. Both Sentinel-4 and -5 are intended to start operation in 2020.

  16. EANM-EORTC general recommendations for sentinel node diagnostics in melanoma.

    PubMed

    Chakera, Annette H; Hesse, Birger; Burak, Zeynep; Ballinger, James R; Britten, Allan; Caracò, Corrado; Cochran, Alistair J; Cook, Martin G; Drzewiecki, Krzysztof T; Essner, Richard; Even-Sapir, Einat; Eggermont, Alexander M M; Stopar, Tanja Gmeiner; Ingvar, Christian; Mihm, Martin C; McCarthy, Stanley W; Mozzillo, Nicola; Nieweg, Omgo E; Scolyer, Richard A; Starz, Hans; Thompson, John F; Trifirò, Giuseppe; Viale, Giuseppe; Vidal-Sicart, Sergi; Uren, Roger; Waddington, Wendy; Chiti, Arturo; Spatz, Alain; Testori, Alessandro

    2009-10-01

    The accurate diagnosis of a sentinel node in melanoma includes a sequence of procedures from different medical specialities (nuclear medicine, surgery, oncology, and pathology). The items covered are presented in 11 sections and a reference list: (1) definition of a sentinel node, (2) clinical indications, (3) radiopharmaceuticals and activity injected, (4) dosimetry, (5) injection technique, (6) image acquisition and interpretation, (7) report and display, (8) use of dye, (9) gamma probe detection, (10) surgical techniques in sentinel node biopsy, and (11) pathological evaluation of melanoma-draining sentinel lymph nodes. If specific recommendations given cannot be based on evidence from original, scientific studies, referral is given to "general consensus" and similar expressions. The recommendations are designed to assist in the practice of referral to, performance, interpretation and reporting of all steps of the sentinel node procedure in the hope of setting state-of-the-art standards for good-quality evaluation of possible spread to the lymphatic system in intermediate-to-high risk melanoma without clinical signs of dissemination.

  17. The Utility of Sentinel Node Biopsy for Sinonasal Melanoma.

    PubMed

    Oldenburg, Michael S; Price, Daniel L

    2017-10-01

    Objective  Report two positive sentinel node biopsies for sinonasal melanoma. Design  Retrospective review. Setting  Academic tertiary care center. Participants  Patients who underwent sentinel node biopsy for sinonasal melanoma between November 1, 2014 and November 1, 2015. Main Outcome Measures  Clinical course. Results  Two patients were identified. Patient 1 (83M) presented with a sinonasal melanoma anterior to the left inferior turbinate and was clinically N0 neck. Lymphoscintigraphy revealed two sentinel nodes in the ipsilateral and three in the contralateral cervical basins. The left level I sentinel node was positive for melanoma and lymphadenectomy showed no additional metastases. Patient 2 (71F) presented after incomplete resection of a sinonasal melanoma of the left posterior maxillary sinus wall and was clinically N0 neck. Lymphoscintigraphy with single-photon emission computed tomography (SPECT/CT) localization revealed one sentinel node in the parapharyngeal space and another in the ipsilateral cervical basin. Metastatic melanoma was found in both nodes and completion lymphadenectomy was negative for additional disease. Both patients developed distant metastasis in less than 1 year after surgical resection but responded well to adjuvant immunomodulatory chemotherapeutic agents. Conclusion  Sentinel node biopsy for sinonasal melanoma can provide crucial clinical evidence of regional metastasis prior to overt clinical signs and symptoms. This intraoperative tool has the potential to improve detection of regional metastasis and improve long-term outcomes of this aggressive malignancy.

  18. Use of Indocyanine Green for Sentinel Lymph Node Biopsy: Case Series and Methods Comparison.

    PubMed

    McGregor, Andrew; Pavri, Sabrina N; Tsay, Cynthia; Kim, Samuel; Narayan, Deepak

    2017-11-01

    Sentinel lymph node biopsy is indicated for patients with biopsy-proven thickness melanoma greater than 1.0 mm. Use of lymphoscintigraphy along with vital blue dyes is the gold standard for identifying sentinel lymph nodes intraoperatively. Indocyanine green (ICG) has recently been used as a method of identifying sentinel lymph nodes. We herein describe a case series of patients who have successfully undergone ICG-assisted sentinel lymph node biopsy for melanoma. We compare 2 imaging systems that are used for ICG-assisted sentinel lymph node biopsy. Fourteen patients underwent ICG-assisted sentinel lymph node biopsy for melanoma using the SPY Elite system (Novadaq, Mississigua, Canada) and the Hamamatsu PDE-Neo probe system (Mitaka USA, Park City, Utah). We analyzed costs for 2 systems that utilize ICG for sentinel lymph node biopsies. Intraoperative use of ICG for sentinel lymph node biopsies was successful in correctly identifying sentinel lymph nodes. There was no difference between the Hamamatsu PDE-Neo probe and SPY Elite systems in the ability to detect sentinel lymph nodes; however, the former was associated with a lower operating cost and ease of use compared with the latter. ICG-assisted sentinel lymph biopsy using the SPY Elite or the Hamamatsu PDE-Neo probe systems for melanoma are comparable in terms of sentinel node detection. The Neo probe system delivers pertinent clinical data with the advantages of lower cost and ease of operation.

  19. Lymphoscintigraphy defines new lymphatic pathways from cutaneous melanoma site: clinical implications and surgical management.

    PubMed

    Marone, Ugo; Aloj, Luigi; Di Monta, Gianluca; Caracò, Corrado

    2011-01-01

    Sentinel lymph node biopsy is commonly applied as staging procedure of regional lymph nodes in patients with cutaneous melanoma. Dynamic lymphoscintigraphy defines the lymphatic pathways from a primary melanoma site and allows to identify the node receiving lymphatic drainage from the primary tumor, which is the sentinel lymph node. In rare cases, lymphoscintigraphy shows sites of lymphatic drainage in nonclassical basins never described in the past when lymphatic drainage was considered only according to the anatomical proximity of the tumor primary site. These peculiar sentinel nodes, so-called "uncommon/interval" nodes, must be surgically removed because they may contain micrometastatic disease and may be the only site of nodal involvement.

  20. Lymphatic mapping and sentinel node identification in squamous cell carcinoma and melanoma of the head and neck.

    PubMed

    Tartaglione, G; Potenza, C; Caggiati, A; Maggiore, M; Gabrielli, F; Migliano, E; Pagan, M; Concolino, F; Ruatti, P

    2002-01-01

    The aim of our study was to evaluate the role of scintigraphy in lymphatic mapping and in the identification of the sentinel lymph node (SLN) in patients with head and neck cancer. Between September 1999 and February 2001 we enrolled 22 consecutive patients with cancer in the head and neck region: five squamous cell carcinomas, one Merkel cell tumor of the cheek, and 16 malignant melanomas. Lymphoscintigraphy was performed three hours before surgery after injection of 30-50 MBq of 99mTc -Nanocoll in 0.3 mL; the dose was fractionated by injecting the radiotracer at two points around the lesion. Static acquisition (anterior and/or lateral views, 512 x 512 matrix, 5 mins pre-set time) was started immediately after the injections so as to visualize the pathways of lymphatic drainage. The skin projection of the SLN was marked with ink. Intraoperative SLN detection was performed with perilesional injection of patent blue. SLNs were found with lymphoscintigraphy in all patients. Thirty-three SLNs were identified: one occipital node, three nodes at the base of the tongue, 10 superficial lateral nodes (external jugular), five submandibular nodes, five submental nodes, three mastoid nodes and six supraclavicular nodes. Biopsy was performed in 21/22 patients. In 20/22 patients the first lymph nodes were visualized in the proximal cranial regions (retroauricular, jugular and submandibular) at five minutes post injection. The SLN positivity rate was 13.6% (three patients). All patients with tumor-positive SLNs were submitted to radical dissection. Poor concordance in the detection of sentinel nodes was observed with patent blue. The flow of nanocolloid in the lymph vessels of the head is rapid. In our experience immediate scintigraphic imaging was essential to visualize the pathways of lymphatic drainage and the first SLN. Radioguided SLN biopsy is therefore recommended within three hours. Injection of patent blue is inadvisable because of the poor concordance with

  1. Fish and wildlife species as sentinels of environmental endocrine disruption

    USGS Publications Warehouse

    Sheffield, S.R.; Matter, J.M.; Rattner, B.A.; Guiney, P.D.; Kendall, Ronald J.; Dickerson, Richard L.; Giesy, John P.; Suk, William P.

    1998-01-01

    This chapter provides an overview of the history and criteria for use of captive and free-ranging fish and wildlife (amphibians, reptiles, birds, and mammals) species as sentinels of potential environmental endocrine disruption. Biochemical, behavioral, physiological, immunological, genetic, reproductive, developmental, and ecological correlates of endocrine disruption in these sentinels are presented and reviewed. In addition, data needs to promote better use of sentinel species in the assessment of endocrine disruption are discussed.

  2. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    PubMed

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  3. CTC Sentinel. Volume 1, Issue, July 2008

    DTIC Science & Technology

    2008-07-01

    1 I n recent months, there has been a spate of seemingly good news in the counter- terrorism arena, as former terrorist leaders and clerics have...28 CTC Sentinel Staff & Contacts JULy 2008 . VoL 1 . IssUE 8 About the CTC Sentinel The Combating Terrorism Center is an independent educational... the Center’s global network of scholars and practitioners in order to understand and confront contemporary threats posed by terrorism and other

  4. Sentinel Lymph Node Evaluation in Women with Cervical Cancer

    PubMed Central

    Holman, Laura L.; Levenback, Charles F.; Frumovitz, Michael

    2014-01-01

    Lymph node status is the most important prognosticator of survival among women with early stage cervical cancer. This means that many cervical cancer patients will undergo pelvic lymphadenectomy as part of their treatment. Unfortunately, this procedure is associated with significant morbidity. Utilizing the sentinel lymph node technique for women with cervical cancer has the potential to decrease this morbidity. Multiple studies have suggested that sentinel lymph node mapping in these patients is feasible with excellent detection rates and sensitivity. This review examines the current body of literature regarding sentinel lymph node biopsy among women with cervical cancer. PMID:24407177

  5. Oral health sentinel-based surveillance: a pilot study on dentinal hypersensitivity pain.

    PubMed

    Guerra, F; Corridore, D; Cocco, F; Arrica, M; Rinaldo, F; Mazur, M; Sanavia, C; Nardi, G M; Campus, G; Ottolenghi, L

    2017-01-01

    Aim of the study is to assess the development of a structured sentinel system for oral health data collection at national level. Furthermore, this pilot study aims to investigate the prevalence data on dentinal sensitivity pain collected through a nationwide network of epidemiological sentinels (dental hygienists). Each sentinel was given a specific number of examinees and periodicity of data collection. Overall, 116 adults were recruited from 19 Regions, 42,24% male and 57,76% female, with a mean age of 26. DH result was consistent with literature data, being 45%. All sentinel completed the standard forms and assured a good compliance. The overall good customer satisfaction assures adhesion of the sentinels to the procedure, and the regular data collection. The pilot study proved the effectiveness of a structured nationwide network of epidemiological sentinels (dental hygienists) for oral health data collection at national level. This methodology can be an essential starting point for periodic comparative studies.

  6. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    PubMed

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  7. SENTINEL-2 Services Library - efficient way for exploration and exploitation of EO data

    NASA Astrophysics Data System (ADS)

    Milcinski, Grega; Batic, Matej; Kadunc, Miha; Kolaric, Primoz; Mocnik, Rok; Repse, marko

    2017-04-01

    With more than 1.5 million scenes available covering over 11 billion sq. kilometers of area and containing half a quadrillion of pixels, Sentinel-2 is becoming one of the most important MSI datasets in the world. However, the vast amount of data makes it difficult to work with. This is certainly an important reason, why the number of Sentinel based applications is not as high as it could be at this point. We will present a Copernicus Award [1] winning service for archiving, processing and distribution of Sentinel data, Sentinel Hub [2]. It makes it easy for anyone to tap into global Sentinel archive and exploit its rich multi-sensor data to observe changes in the land. We will demonstrate, how one is able not just to observe imagery all over the world but also to create its own statistical analysis in a matter of seconds, performing comparison of different sensors through various time segments. The result can be immediately observed in any GIS tool or exported as a raster file for post-processing. All of these actions can be performed on a full, worldwide, S-2 archive (multi-temporal and multi-spectral). To demonstrate the technology, we created a publicly accessible web application, called "Sentinel Playground" [3], which makes it possible to query Sentinel-2 data anywhere in the world, and experts-oriented tool "EO Browser" [4], where it is also possible to observe land changes through longer period by using historical Landsat data as well. [1] http://www.copernicus-masters.com/index.php?anzeige=press-2016-03.html [2] http://www.sentinel-hub.com [3] http://apps.sentinel-hub.com/sentinel-playground/ [4] http://apps.eocloud.sentinel-hub.com/eo-browser/

  8. Radionavigated detection of sentinel nodes in breast carcinoma--first experiences of our department.

    PubMed

    Duchaj, B; Chvalny, P; Vesely, J; Makaiova, I; Durdik, S; Straka, V; Palaj, J; Procka, V; Aksamitova, K; Skraskova, S; Banki, P; Kovacova, S; Galbavy, S

    2010-01-01

    Biopsy and histological evaluation of sentinel lymphatic node limits the axillary node dissection only in cases of positive histological finding and decreases the occurrence of postoperative complications related to the axillary node dissection. We used radiotracer SentiScint, Medi-Radiopharma Ltd, Hungary and preoperatively administered blue dye--Blue Patenté V, Guebert, Aulnay-Sous-Bios, France. 11 (18%) patients were subdued to deep peritimorous application of radiotracer, 10 (16.4%) to sub/intradermal application over the lesions and n 40 (65.6%) patients the application was sub/intradermal and periareolar. The patients underwent an operation protocol of corresponding quadrantectomy, radionavigated blue-dye sentinel node biopsy and axillary dissection. From May 2006 to June 2008, we examined 61 patients with breast carcinoma. They underwent radionavigated and blue-dye sentinel node biopsy. We detected 57 (93.4%) sentinel nodes with preoperative scintigraphy, of which only 51 (83.6%) were detected peroperatively and underwent histological evaluation. In six (9.8%) cases, the "frozen cut" histology of the primary lesion had shown a benign lesion; hence no sentinel node biopsy or axillary disection was performed. 12 (19.7%) of 51 histologically evaluated sentinel nodes had metastatic invasion. We retrospectively compared the histological fund in sentinel and axillary nodes in patients with metastatic sentinel nodes. In 6 (16.6%) cases, the sentinel node was positive of metastatic invasion but axillary nodes were histologically negative, in 6 (16.6%) cases the sentinel node and axillary nodes were positive for metastatic invasion. We observed falsely negative findings in 3 (8.3%) patients with negative histological fund in the sentinel node, but positive axillary nodes (Tab. 3, Fig. 2, Ref. 11). Full Text (Free, PDF) www.bmj.sk.

  9. Sentinel nodes identified by computed tomography-lymphography accurately stage the axilla in patients with breast cancer

    PubMed Central

    2013-01-01

    Background Sentinel node biopsy often results in the identification and removal of multiple nodes as sentinel nodes, although most of these nodes could be non-sentinel nodes. This study investigated whether computed tomography-lymphography (CT-LG) can distinguish sentinel nodes from non-sentinel nodes and whether sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Methods This study included 184 patients with breast cancer and clinically negative nodes. Contrast agent was injected interstitially. The location of sentinel nodes was marked on the skin surface using a CT laser light navigator system. Lymph nodes located just under the marks were first removed as sentinel nodes. Then, all dyed nodes or all hot nodes were removed. Results The mean number of sentinel nodes identified by CT-LG was significantly lower than that of dyed and/or hot nodes removed (1.1 vs 1.8, p <0.0001). Twenty-three (12.5%) patients had ≥2 sentinel nodes identified by CT-LG removed, whereas 94 (51.1%) of patients had ≥2 dyed and/or hot nodes removed (p <0.0001). Pathological evaluation demonstrated that 47 (25.5%) of 184 patients had metastasis to at least one node. All 47 patients demonstrated metastases to at least one of the sentinel nodes identified by CT-LG. Conclusions CT-LG can distinguish sentinel nodes from non-sentinel nodes, and sentinel nodes identified by CT-LG can accurately stage the axilla in patients with breast cancer. Successful identification of sentinel nodes using CT-LG may facilitate image-based diagnosis of metastasis, possibly leading to the omission of sentinel node biopsy. PMID:24321242

  10. Joint Sentinel-1 and SMAP data assimilation to improve soil moisture estimates

    NASA Astrophysics Data System (ADS)

    Lievens, H.; Reichle, R. H.; Liu, Q.; De Lannoy, G.; Dunbar, R. S.; Kim, S.; Das, N. N.; Cosh, M. H.; Walker, J. P.; Wagner, W.

    2017-12-01

    SMAP (Soil Moisture Active and Passive) radiometer observations at 40 km resolution are routinely assimilated into the NASA Catchment Land Surface Model (CLSM) to generate the SMAP Level 4 Soil Moisture product. The use of C-band radar backscatter observations from Sentinel-1 has the potential to add value to the radiance assimilation by increasing the level of spatial detail. The specifications of Sentinel-1 are appealing, particularly its high spatial resolution (5 by 20 m in interferometric wide swath mode) and frequent revisit time (6 day repeat cycle for the Sentinel-1A and Sentinel-1B constellation). However, the shorter wavelength of Sentinel-1 observations implies less sensitivity to soil moisture. This study investigates the value of Sentinel-1 data for hydrologic simulations by assimilating the radar observations into CLSM, either separately from or simultaneously with SMAP radiometer observations. To facilitate the assimilation of the radar observations, CLSM is coupled to the water cloud model, simulating the radar backscatter as observed by Sentinel-1. The innovations, i.e. differences between observations and simulations, are converted into increments to the model soil moisture state through an Ensemble Kalman Filter. The assimilation impact is assessed by comparing 3-hourly, 9 km surface and root-zone soil moisture simulations with in situ measurements from 9 km SMAP core validation sites and sparse networks, from May 2015 to 2017. The Sentinel-1 assimilation consistently improves surface soil moisture, whereas root-zone impacts are mostly neutral. Relatively larger improvements are obtained from SMAP assimilation. The joint assimilation of SMAP and Sentinel-1 observations performs best, demonstrating the complementary value of radar and radiometer observations.

  11. The Sentinel-4 detectors: architecture and performance

    NASA Astrophysics Data System (ADS)

    Skegg, Michael P.; Hermsen, Markus; Hohn, Rüdiger; Williges, Christian; Woffinden, Charles; Levillain, Yves; Reulke, Ralf

    2017-09-01

    The Sentinel-4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program. SENTINEL-4 will provide accurate measurements of trace gases from geostationary orbit, including key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Key to achieving these atmospheric measurements are the two CCD detectors, covering the wavelengths in the ranges 305 nm to 500 nm (UVVIS) and 750 to 775 nm (NIR) respectively. The paper describes the architecture, and operation of these two CCD detectors, which have an unusually high full-well capacity and a very specific architecture and read-out sequence to match the requirements of the Sentinel- 4 instrument. The key performance aspects and their verification through measurement are presented, with a focus on an unusual, bi-modal dark signal generation rate observed during test.

  12. Sentinel-1 Precise Orbit Calibration and Validation

    NASA Astrophysics Data System (ADS)

    Monti Guarnieri, Andrea; Mancon, Simone; Tebaldini, Stefano

    2015-05-01

    In this paper, we propose a model-based procedure to calibrate and validate Sentinel-1 orbit products by the Multi-Squint (MS) phase. The technique allows to calibrate an interferometric pair geometry by refining the slave orbit with reference to the orbit of a master image. Accordingly, we state the geometric model of the InSAR phase as function of positioning errors of targets and slave track; and the MS phase model as derivative of the InSAR phase geometric model with respect to the squint angle. In this paper we focus on the TOPSAR acquisition modes of Sentinel-1 (IW and EW) assuming at the most a linear error in the known slave trajectory. In particular, we describe a dedicated methodology to prevent InSAR phase artifacts on data acquired by the TOPSAR acquisition mode. Experimental results obtained by interferometric pairs acquired by Sentinel-1 sensor will be displayed.

  13. Citrullus lanatus `Sentinel' (Watermelon) Extract Reduces Atherosclerosis in LDL Receptor Deficient Mice

    PubMed Central

    Poduri, Aruna; Rateri, Debra L.; Saha, Shubin K.; Saha, Sibu; Daugherty, Alan

    2012-01-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar `sentinel', on hypercholesterolemia-induced atherosclerosis in mice. Male LDL receptor deficient mice at 8 weeks old were given either C. lanatus `sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water, while fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus `sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus `sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake, and urine output between the two groups. C. lanatus `sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate/low density lipoprotein cholesterol. Plasma concentrations of MCP-1 and IFN-γ were decreased and IL-10 increased in mice consuming C. lanatus `sentinel' extract. Intake of C. lanatus `sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus `sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. PMID:22902326

  14. U.S. Geological Survey distribution of European Space Agency's Sentinel-2 data

    USGS Publications Warehouse

    Pieschke, Renee L.

    2017-03-31

    A partnership established between the European Space Agency (ESA) and the U.S. Geological Survey (USGS) allows for USGS storage and redistribution of images acquired by the MultiSpectral Instrument (MSI) on the European Union's Sentinel-2 satellite mission. The MSI data are acquired from a pair of satellites, Sentinel-2A and Sentinel-2B, which are part of a larger set of ESA missions focusing on different aspects of Earth observation. The primary purpose of the Sentinel-2 series is to collect multispectral imagery over the Earth’s land surfaces, large islands, and inland and coastal waters. Sentinel-2A was launched in 2015 and Sentinel-2B launched in 2017.The collaborative effort between ESA and USGS provides for public access and redistribution of global acquisitions of Sentinel-2 data at no cost, which allows users to download the MSI imagery from USGS access systems such as Earth- Explorer, in addition to the ESA Sentinels Scientific Data Hub. The MSI sensor acquires 13 spectral bands that are highly complementary to data acquired by the USGS Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+). The product options from USGS include a Full-Resolution Browse (FRB) image product generated by USGS, along with a 100-kilometer (km) by 100-km tile-based Level-1C top-of-atmosphere (TOA) reflectance product that is very similar (but not identical) to the currently (2017) distributed ESA Level 1C product.

  15. Use of sentinel lymph node biopsy for melanoma of the head and neck.

    PubMed

    Kilpatrick, Lauren A; Shen, Perry; Stewart, John H; Levine, Edward A

    2007-08-01

    Sentinel lymph node biopsy (SLN) is a well-accepted procedure for truncal and extremity melanoma (T&E). However, its role in melanoma of the head and neck (H&N) remains controversial. Complex lymphatic and vascular drainage make SLN more challenging in this region. This study was done to evaluate the results of SLN for H&N versus T&E melanoma. Three hundred sixteen patients who underwent SLN for melanoma using a double indicator technique were identified from a prospective database. Records were analyzed retrospectively. Statistical analysis was performed using chi2, t test, or Mann-Whitney U test to evaluate the results, as appropriate. H&N was found in 87 cases (27.5%). The mean age was 63.2 and 53.2 years for H&N and T&E melanoma (P < 0.001), respectively. 99Technetium positivity (89.7% H&N versus 99.6% T&E, P < 0.001) and isosulfan blue positivity (85.1% H&N versus 91.7% T&E, P = 0.08) were more likely in T&E melanoma. There was a significant difference between H&N and T&E melanoma with respect to the incidence of failed SLN, defined as no sentinel nodes identified intraoperatively (8.0% versus 0%, P < 0.001). Both groups had similar rates of positive intraoperative imprint cytologic examination (4.6% H&N versus 6.1% T&E, P > 0.5). There was a trend suggesting a higher mean number of sentinel lymph nodes found (3.1 versus 2.7, P = 0.1) in H&N melanoma. The total number of lymph nodes found in dissection specimens (20.9 versus 21.9, P = 0.45), the total number of positive lymph nodes (3.5 versus 1.6, P = 0.32), the incidence of any recurrence (19.5% versus 12.7%, P = 0.2), and time to recurrence (14.2 versus 20.6 months, P = 0.18) were similar between H&N and T&E melanoma. SLN mapping of H&N lesions is more difficult than at other sites. However, rates of nodal positivity are similar to melanoma of the trunk and extremities. Therefore, despite being more demanding, SLN is useful in diagnosis and treatment of melanomas of the head and neck.

  16. Sentinel-5: the new generation European operational atmospheric chemistry mission in polar orbit

    NASA Astrophysics Data System (ADS)

    Pérez Albiñana, Abelardo; Erdmann, Matthias; Wright, Norrie; Martin, Didier; Melf, Markus; Bartsch, Peter; Seefelder, Wolfgang

    2017-08-01

    Sentinel-5 is an Earth Observation instrument to be flown on the Metop Second Generation (Metop-SG) satellites with the fundamental objective of monitoring atmospheric composition from polar orbit. The Sentinel-5 instrument consists of five spectrometers to measure the solar spectral radiance backscattered by the earth atmosphere in five bands within the UV (270nm) to SWIR (2385nm) spectral range. Data provided by Sentinel-5 will allow obtaining the distribution of important atmospheric constituents such as ozone, on a global daily basis and at a finer spatial resolution than its precursor instruments on the first generation of Metop satellites. The launch of the first Metop-SG satellite is foreseen for 2021. The Sentinel-5 instrument is being developed by Airbus DS under contract to the European Space Agency. The Sentinel-5 mission is part of the Space Component of the Copernicus programme, a joint initiative by ESA, EUMETSAT and the European Commission. The Preliminary Design Review (PDR) for the Sentinel-5 development was successfully completed in 2015. This paper provides a description of the Sentinel-5 instrument design and data calibration.

  17. Lymphoscintigraphy Defines New Lymphatic Pathways from Cutaneous Melanoma Site: Clinical Implications and Surgical Management

    PubMed Central

    Marone, Ugo; Aloj, Luigi; Di Monta, Gianluca; Caracò, Corrado

    2011-01-01

    Sentinel lymph node biopsy is commonly applied as staging procedure of regional lymph nodes in patients with cutaneous melanoma. Dynamic lymphoscintigraphy defines the lymphatic pathways from a primary melanoma site and allows to identify the node receiving lymphatic drainage from the primary tumor, which is the sentinel lymph node. In rare cases, lymphoscintigraphy shows sites of lymphatic drainage in nonclassical basins never described in the past when lymphatic drainage was considered only according to the anatomical proximity of the tumor primary site. These peculiar sentinel nodes, so-called “uncommon/interval” nodes, must be surgically removed because they may contain micrometastatic disease and may be the only site of nodal involvement. PMID:22242203

  18. Soiled-bedding Sentinel Detection of Murine Norovirus 4

    PubMed Central

    Manuel, Christopher A; Hsu, Charlie C; Riley, Lela K; Livingston, Robert S

    2008-01-01

    According to serologic surveys, murine norovirus (MNV) is the most prevalent viral pathogen infecting mice used in biomedical research. However, the use of sentinel mice to detect MNV-infected mouse populations has not been evaluated thoroughly. To this end, an experimental method of soiled bedding transfer was created to mimic a quarterly sentinel monitoring program. Soiled bedding (15 or 30 cm3) from ICR mice experimentally infected with MNV4 was transferred weekly to cages of pair-housed 4-wk-old ICR mice. After 12 wk, both mice in 80% (4 of 5) of cages receiving either 15 or 30 cm3 of soiled bedding were seropositive for MNV and were shedding virus in feces. To evaluate the stability of MNV RNA in mouse feces, fecal pellets from MNV-infected sentinel mice were stored at room temperature for as long as 14 d. After storage, all fecal samples tested positive for MNV by RT-PCR. To determine whether fecal samples could be pooled for MNV detection, 1 MNV-positive fecal pellet was combined with either 9 or 19 MNV-negative fecal pellets. All pooled fecal samples were positive for MNV by RT-PCR at both dilutions. These data indicate that although MNV-infected mouse populations can be detected by exposing sentinel mice to MNV-contaminated bedding, detection failures can occur. In addition, there was high agreement in the MNV infection status of cohoused sentinel mice. These data also demonstrate that MNV is readily detectable in pooled fecal samples and in mouse feces stored at room temperature for 2 wk. PMID:18459710

  19. Peritoneal Drainage Versus Pleural Drainage After Pediatric Cardiac Surgery.

    PubMed

    Gowda, Keshava Murty Narayana; Zidan, Marwan; Walters, Henry L; Delius, Ralph E; Mastropietro, Christopher W

    2014-07-01

    We aimed to determine whether infants undergoing cardiac surgery would more efficiently attain negative fluid balance postoperatively with passive peritoneal drainage as compared to traditional pleural drainage. A prospective, randomized study including children undergoing repair of tetralogy of Fallot (TOF) or atrioventricular septal defect (AVSD) was completed between September 2011 and June 2013. Patients were randomized to intraoperative placement of peritoneal catheter or right pleural tube in addition to the requisite mediastinal tube. The primary outcome measure was fluid balance at 48 hours postoperatively. Variables were compared using t tests or Fisher exact tests as appropriate. A total of 24 patients were enrolled (14 TOF and 10 AVSD), with 12 patients in each study group. Mean fluid balance at 48 hours was not significantly different between study groups, -41 ± 53 mL/kg in patients with periteonal drainage and -9 ± 40 mL/kg in patients with pleural drainage (P = .10). At 72 hours however, postoperative fluid balance was significantly more negative with peritoneal drainage, -52.4 ± 71.6 versus +2.0 ± 50.6 (P = .04). On subset analysis, fluid balance at 48 hours in patients with AVSD was more negative with peritoneal drainage as compared to pleural, -82 ± 51 versus -1 ± 38 mL/kg, respectively (P = .02). Fluid balance at 48 hours in patients with TOF was not significantly different between study groups. Passive peritoneal drainage may more effectively facilitate negative fluid balance when compared to pleural drainage after pediatric cardiac surgery, although this benefit is not likely universal but rather dependent on the patient's underlying physiology. © The Author(s) 2014.

  20. Animals as sentinels of chemical terrorism agents: an evidence-based review.

    PubMed

    Rabinowitz, Peter; Wiley, James; Odofin, Lynda; Wilcox, Matthew; Dein, F Joshua

    2008-02-01

    The goal of this systematic review was to identify evidence that animals could serve as sentinels of an attack with a chemical terrorism agent. The biomedical literature was systematically searched for evidence that wild or domestic animals exposed to certain chemical weapons of terrorism had either greater susceptibility, shorter latency period, or increased exposure risk versus humans. Additionally, we searched for documented reports of such animals historically serving as sentinels for chemical warfare agents. For a small number of agents, there was limited evidence that domestic and/or wild animals could provide sentinel information to humans following an airborne attack with chemical agents, usually related to increased potential for environmental exposure. Some of this evidence was based on anecdotal case reports, and in many cases high quality chemical terrorism agent evidence regarding comparative susceptibility, exposure, and latency between humans and sentinel animal species was not found. Currently, there is insufficient evidence for routine use of animals as sentinels for airborne chemical warfare agents. At the same time, Poison Center surveillance systems should include animal calls, and greater communication between veterinarians and physicians could help with preparedness for a chemical terrorism attack. Further analysis of comparative chemical warfare agent toxicity between sentinel animal species and humans is needed.

  1. Citrullus lanatus 'sentinel' (watermelon) extract reduces atherosclerosis in LDL receptor-deficient mice.

    PubMed

    Poduri, Aruna; Rateri, Debra L; Saha, Shubin K; Saha, Sibu; Daugherty, Alan

    2013-05-01

    Watermelon (Citrullus lanatus or C. lanatus) has many potentially bioactive compounds including citrulline, which may influence atherosclerosis. In this study, we determined the effects of C. lanatus, provided as an extract of the cultivar 'sentinel,' on hypercholesterolemia-induced atherosclerosis in mice. Male low-density lipoprotein receptor-deficient mice at 8 weeks old were given either C. lanatus 'sentinel' extract (2% vol/vol; n=10) or a mixture of matching carbohydrates (2% vol/vol; n=8) as the control in drinking water while being fed a saturated fat-enriched diet for 12 weeks ad libitum. Mice consuming C. lanatus 'sentinel' extract had significantly increased plasma citrulline concentrations. Systolic blood pressure was comparable between the two groups. Consumption of C. lanatus 'sentinel' extract led to lower body weight and fat mass without influencing lean mass. There were no differences in food and water intake and in urine output between the two groups. C. lanatus 'sentinel' extract administration decreased plasma cholesterol concentrations that were attributed to reductions of intermediate-/low-density lipoprotein cholesterol. Plasma concentrations of monocyte chemoattractant protein-1 and interferon-gamma were decreased and those of interleukin-10 were increased in mice consuming C. lanatus 'sentinel' extract. Intake of C. lanatus 'sentinel' extract resulted in reductions of atherosclerosis in both aortic arch and thoracic regions. In conclusion, consumption of C. lanatus 'sentinel' extract led to reduced body weight gain, decreased plasma cholesterol concentrations, improved homeostasis of pro- and anti-inflammatory cytokines, and attenuated development of atherosclerosis without affecting systolic blood pressure in hypercholesterolemic mice. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Sentinel lymph node biopsy for early oral cancers: Westmead Hospital experience.

    PubMed

    Abdul-Razak, Muzib; Chung, Hsiang; Wong, Eva; Palme, Carsten; Veness, Michael; Farlow, David; Coleman, Hedley; Morgan, Gary

    2017-01-01

    Sentinel lymph node biopsy (SLNB) has become an alternative option to elective neck dissection (END) for early oral cavity squamous cell carcinoma (OCSCC) outside of Australia. We sought to assess the technical feasibility of SLNB and validate its accuracy against that of END in an Australian setting. We performed a prospective cohort study consisting of 30 consecutive patients with cT 1 - 2 N 0 OCSCC referred to the Head and Neck Cancer Service, Westmead Hospital, Sydney, between 2011 and 2014. All patients underwent SLNB followed by immediate selective neck dissection (levels I-III). A total of 30 patients were diagnosed with an early clinically node-negative OCSCC (seven cT1 and 23 cT2), with the majority located on the oral tongue. A median of three (range: 1-14) sentinel nodes were identified on lymphoscintigraphy, and all sentinel nodes were successfully retrieved, with 50% having a pathologically positive sentinel node. No false-negative sentinel nodes were identified using selective neck dissection as the gold standard. The negative predictive value (NPV) of SLNB was 100%, with 40% having a sentinel node identified outside the field of planned neck dissection on lymphoscintigraphy. Of these, one patient had a positive sentinel node outside of the ipsilateral supraomohyoid neck dissection template. SLNB for early OCSCC is technically feasible in an Australian setting. It has a high NPV and can potentially identify at-risk lymphatic basins outside the traditional selective neck dissection levels even in well-lateralized lesions. © 2016 Royal Australasian College of Surgeons.

  3. Sentinel lymph node biopsy in breast cancer

    PubMed Central

    Alsaif, Abdulaziz A.

    2015-01-01

    Objectives: To report our experience in sentinel lymph node biopsy (SLNB) in early breast cancer. Methods: This is a retrospective study conducted at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia between January 2005 and December 2014. There were 120 patients who underwent SLNB with frozen section examination. Data collected included the characteristics of patients, index tumor, and sentinel node (SN), SLNB results, axillary recurrence rate and SLNB morbidity. Results: There were 120 patients who had 123 cancers. Sentinel node was identified in 117 patients having 120 tumors (97.6% success rate). No SN was found intraoperatively in 3 patients. Frozen section results showed that 95 patients were SN negative, those patients had no immediate axillary lymph node dissection (ALND), whereas 25 patients were SN positive and subsequently had immediate ALND. Upon further examination of the 95 negative SN’s by hematoxylin & eosin (H&E) and immunohistochemical staining for doubtful H&E cases, 10 turned out to have micrometastases (6 had delayed ALND and 4 had no further axillary surgery). Median follow up of patients was 35.5 months and the mean was 38.8 months. There was one axillary recurrence observed in the SN negative group. The morbidity of SLNB was minimal. Conclusion: The obtainable results from our local experience in SLNB in breast cancer, concur with that seen in published similar literature in particular the axillary failure rate. Sentinel lymph node biopsy resulted in minimal morbidity. PMID:26318461

  4. Verification of the SENTINEL-4 Focal Plane Subsystem

    NASA Astrophysics Data System (ADS)

    Williges, C.; Hohn, R.; Rossmann, H.; Hilbert, S.; Uhlig, M.; Buchwinkler, K.; Reulke, R.

    2017-05-01

    The Sentinel-4 payload is a multi-spectral camera system which is designed to monitor atmospheric conditions over Europe. The German Aerospace Center (DLR) in Berlin, Germany conducted the verification campaign of the Focal Plane Subsystem (FPS) on behalf of Airbus Defense and Space GmbH, Ottobrunn, Germany. The FPS consists, inter alia, of two Focal Plane Assemblies (FPAs), one for the UV-VIS spectral range (305 nm … 500 nm), the second for NIR (750 nm … 775 nm). In this publication, we will present in detail the opto-mechanical laboratory set-up of the verification campaign of the Sentinel-4 Qualification Model (QM) which will also be used for the upcoming Flight Model (FM) verification. The test campaign consists mainly of radiometric tests performed with an integrating sphere as homogenous light source. The FPAs have mainly to be operated at 215 K ± 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Furthermore selected test analyses and results will be presented, showing that the Sentinel-4 FPS meets specifications.

  5. Sentinel lymph node mapping in melanoma with technetium-99m dextran.

    PubMed

    Neubauer, S; Mena, I; Iglesis, R; Schwartz, R; Acevedo, J C; Leon, A; Gomez, L

    2001-06-01

    The aim of this work is to evaluate the capability of Tc99m B Dextran as a lymphoscintigraphic agent in the detection of the sentinel node in skin lesions. Forty-one patients with melanomas (39) and Merkel cell tumors (2) had perilesional intradermal injection of Tc99m-Dextran 2 hours before surgery. Serial gamma camera images and a handheld gamma probe were used to direct sentinel node biopsy. In 39/41 patients, lymph channels and 52 sentinel nodes (one to three sentinel nodes/patient) could be visualized. In one patient, with a dorsal melanoma, no lymph channels or lymph nodes could be demonstrated on the images and only minimal radioactivity was found in the regional nodes with the probe. Another patient with a facial lesion failed to demonstrate lymph channels or nodes. No adverse reactions were observed. Tc99m-Dextran provided good definition of lymph channels and sentinel node localization, without the risks related to the use of potentially hazardous labeled materials of biological origin.

  6. Sentinel-1 Mission Overview and Implementation Status

    NASA Astrophysics Data System (ADS)

    Davidson, M.; Attema, E.; Snoeij, P.; Levrini, G.

    2009-04-01

    Sentinel-1 is an imaging radar mission at C-band consisting of a constellation of two satellites aimed at providing continuity of all-weather day-and-night supply of imagery for user services. Special emphasis is placed on services identified in ESA's GMES service elements program and on projects funded by the European Union Framework Programmes. Three priorities (fast-track services) for the mission have been identified by user consultation working groups of the European Union: Marine Core Services, Land Monitoring and Emergency Services. These cover applications such as: - Monitoring sea ice zones and the arctic environment - Surveillance of marine environment - Monitoring land surface motion risks - Mapping of land surfaces: forest, water and soil, agriculture - Mapping in support of humanitarian aid in crisis situations. The Sentinel 1 space segment will be designed and built by an industrial consortium with Thales Alenia Space Italia as prime contractor and EADS Astrium GmbH as C-SAR instrument responsible. Data products from current and previous ESA missions including ERS-1, ERS-2 and Envisat missions form the basis for many of the pilot GMES services. Consequently Sentinel-1 data maintain data quality levels of the Agency‘s previous SAR missions in terms of spatial resolution, sensitivity, accuracy, polarization and wavelength. Nonetheless, the Sentinel-1 synthetic aperture radar (SAR) constellation represents a completely new approach to SAR mission design by ESA in direct response to the operational needs for SAR data expressed under the EU-ESA Global Monitoring for Environment and Security (GMES) programme. The Sentinel-1 constellation is expected to provide near daily coverage over Europe and Canada, global coverage all independent of weather with delivery of radar data within 1 hour of acquisition - all vast improvements with respect to the existing SAR systems. The continuity of C-band SAR data combined with the greatly improved data provision is

  7. Breast cancer sentinel node scintigraphy: differences between imaging results 1 and 2 h after injection.

    PubMed

    Wondergem, Maurits; Hobbelink, Monique G G; Witkamp, Arjen J; van Hillegersberg, Richard; de Keizer, Bart

    2012-11-01

    Timing of image acquisition in breast cancer sentinel node scintigraphy remains a subject of debate. Therefore, the performance of our protocol in which images are acquired 1 and 2 h after injection was evaluated. The results of sentinel node scintigraphy 1 and 2 h after injection were compared with regard to the sentinel lymph nodes visualized. We studied 132 patients who were consecutively referred for sentinel lymph node biopsy. 99mTc-albumine nanocolloid (120 MBq) was injected peritumourally into patients with palpable tumours and intratumourally into patients with nonpalpable tumours. All scintigraphic images taken for the sentinel node procedure were evaluated. The number of sentinel nodes per anatomic localization and the interpretability of the images were scored. A total of 132 patients underwent sentinel node scintigraphy 1 h after injection. Of these, 117 patients also underwent sentinel node scintigraphy 2 h after injection. An axillary sentinel node was visualized in 79.5 and 95.7% of patients, respectively, 1 and 2 h after injection. In 20.5% of the patients the images acquired 1 h after injection did not show a sentinel node. Furthermore, in all procedures, the images 1 h after injection were of no added value to those acquired 2 h after injection. Scintigraphic imaging 2 h after a single peritumoural or intratumoural administration of about 120 MBq 99mTc-albumine nanocolloid yields an axillary sentinel node in over 95% of cases. Imaging 1 h after injection is of no additional value and can be omitted.

  8. Sentinel lymph node biopsy from the vantage point of an oncologic surgeon.

    PubMed

    Wilson, Lori L

    2009-01-01

    Sentinel lymph node biopsy has greatly influenced the surgical management of clinically localized primary melanoma. Lymphatic mapping and sentinel lymph node biopsy have been used for the selective management of the draining regional lymph node basin of primary cutaneous melanoma. Oncologic surgeons have adopted this procedure to selectively identify occult nodal status in melanoma patients who are at a higher risk of regional metastasis. The current standard of treatment of tumor-positive sentinel lymph node metastasis is immediate completion lymphadenectomy, but considerable debate surrounds the utility of this procedure. This contribution reviews development, technical aspects, selective management of the lymph node basin, and sentinel lymph node biopsy techniques.

  9. Marine mammals as sentinel species for oceans and human health.

    PubMed

    Bossart, G D

    2011-05-01

    The long-term consequences of climate change and potential environmental degradation are likely to include aspects of disease emergence in marine plants and animals. In turn, these emerging diseases may have epizootic potential, zoonotic implications, and a complex pathogenesis involving other cofactors such as anthropogenic contaminant burden, genetics, and immunologic dysfunction. The concept of marine sentinel organisms provides one approach to evaluating aquatic ecosystem health. Such sentinels are barometers for current or potential negative impacts on individual- and population-level animal health. In turn, using marine sentinels permits better characterization and management of impacts that ultimately affect animal and human health associated with the oceans. Marine mammals are prime sentinel species because many species have long life spans, are long-term coastal residents, feed at a high trophic level, and have unique fat stores that can serve as depots for anthropogenic toxins. Marine mammals may be exposed to environmental stressors such as chemical pollutants, harmful algal biotoxins, and emerging or resurging pathogens. Since many marine mammal species share the coastal environment with humans and consume the same food, they also may serve as effective sentinels for public health problems. Finally, marine mammals are charismatic megafauna that typically stimulate an exaggerated human behavioral response and are thus more likely to be observed.

  10. Exploring Capabilities of SENTINEL-2 for Vegetation Mapping Using Random Forest

    NASA Astrophysics Data System (ADS)

    Saini, R.; Ghosh, S. K.

    2018-04-01

    Accurate vegetation mapping is essential for monitoring crop and sustainable agricultural practice. This study aims to explore the capabilities of Sentinel-2 data over Landsat-8 Operational Land Imager (OLI) data for vegetation mapping. Two combination of Sentinel-2 dataset have been considered, first combination is 4-band dataset at 10m resolution which consists of NIR, R, G and B bands, while second combination is generated by stacking 4 bands having 10 m resolution along with other six sharpened bands using Gram-Schmidt algorithm. For Landsat-8 OLI dataset, six multispectral bands have been pan-sharpened to have a spatial resolution of 15 m using Gram-Schmidt algorithm. Random Forest (RF) and Maximum Likelihood classifier (MLC) have been selected for classification of images. It is found that, overall accuracy achieved by RF for 4-band, 10-band dataset of Sentinel-2 and Landsat-8 OLI are 88.38 %, 90.05 % and 86.68 % respectively. While, MLC give an overall accuracy of 85.12 %, 87.14 % and 83.56 % for 4-band, 10-band Sentinel and Landsat-8 OLI respectively. Results shown that 10-band Sentinel-2 dataset gives highest accuracy and shows a rise of 3.37 % for RF and 3.58 % for MLC compared to Landsat-8 OLI. However, all the classes show significant improvement in accuracy but a major rise in accuracy is observed for Sugarcane, Wheat and Fodder for Sentinel 10-band imagery. This study substantiates the fact that Sentinel-2 data can be utilized for mapping of vegetation with a good degree of accuracy when compared to Landsat-8 OLI specifically when objective is to map a sub class of vegetation.

  11. Sentinel events predicting later unwanted sex among girls: A national survey in Haiti, 2012.

    PubMed

    Sumner, Steven A; Marcelin, Louis H; Cela, Toni; Mercy, James A; Lea, Veronica; Kress, Howard; Hillis, Susan D

    2015-12-01

    Sexual violence against children is a significant global public health problem, yet limited studies exist from low-resource settings. In Haiti we conducted the country's first, nationally representative survey focused on childhood violence to help inform the development of a national action plan for violence against children. The Haiti Violence Against Children Survey was a household-level, multistage, cluster survey among youth age 13-24. In this analysis we sought to determine whether sexual violence sentinel events (unwanted sexual touching or unwanted attempted sex) were predictive of later unwanted, completed, penetrative sex in Haiti. We also sought to explore characteristics of sentinel events and help-seeking behavior among Haitian children. Multivariable logistic regression was used to test associations between sentinel events and later unwanted, completed, penetrative sex. Overall, 1,457 females reported on experiences of sexual violence occurring in childhood (before age 18). A sentinel event occurred in 40.4% of females who experienced subsequent unwanted completed sex. Females experiencing a sentinel event were approximately two and a half times more likely to experience later unwanted completed sex (adjusted odds ratio=2.40, p=.004) compared to individuals who did not experience a sentinel event. The mean lag time from first sentinel event to first unwanted completed sex was 2.3 years. Only half (54.6%) of children experiencing a sentinel event told someone about their experience of sexual violence. Among children, sentinel events occur frequently before later acts of completed unwanted sex and may represent a useful point of intervention. Reporting of sexual violence by children in Haiti is low and can be improved to better act on sentinel events. Published by Elsevier Ltd.

  12. The Copernicus Sentinel 4 mission: a geostationary imaging UVN spectrometer for air quality monitoring

    NASA Astrophysics Data System (ADS)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Veihelmann, Ben; Riedl, S.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus Defence and Space under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe". Sentinel-4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, methane, and aerosol properties over Europe and adjacent regions from a geostationary orbit (see Fig. 1). In the family of already flown UVN spectrometers (SCIAMACHY, OMI, GOME and GOME 2) and of those spectrometers currently under development (Sentinel-5p and Sentinel-5), Sentinel-4 is unique in being the first geostationary UVN mission. Furthermore, thanks to its 60-minutes repeat cycle measurements and high spatial resolution (8x8 km2), Sentinel-4 will increase the frequency of cloud-free observations, which is necessary to assess troposphere variability. Two identical Sentinel-4 instruments (PFM and FM-2) will be embarked, as Customer Furnished Item (CFI), fully verified, qualified and calibrated respectively onto two EUMETSAT satellites: Meteosat Third Generation-Sounder 1 and 2 (MTG-S1 and MTG-S2), whose Flight Acceptance Reviews are presently planned respectively in Q4 2021 and Q1 2030. This paper gives an overview of the Sentinel-4 system1 architecture, its design and development status, current performances and the key technological challenges.

  13. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    PubMed

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  14. Solar Sentinels: Report of the Science and Technology Definition Team

    NASA Technical Reports Server (NTRS)

    2006-01-01

    The goal of NASA s Living With a Star (LWS) program is to develop the scientific understanding necessary to effectively address those aspects of the connected Sun Earth system that directly affect life and society. Along with the other elements of LWS, Solar Sentinels aims to discover, understand, and model the heliospheric initiation, propagation, and solar connection of those energetic phenomena that adversely affect space exploration and life and society here on Earth. The Solar Sentinels mission will address the following questions: (1) How, where, and under what circumstances are solar energetic particles (SEPs) accelerated to high energies and how do they propagate through the heliosphere? And (2) How are solar wind structures associated with these SEPs, like CMEs, shocks, and high-speed streams, initiated, propagate, evolve, and interact in the inner heliosphere? The Sentinels STDT recommends implementing this mission in two portions, one optimized for inner heliospheric in-situ measurements and the other for solar remote observations. Sentinels will greatly enhance the overall LWS science return.

  15. [Exclusive use of blue dye to detect sentinel lymph nodes in breast cancer].

    PubMed

    Bühler H, Simón; Rojas P, Hugo; Cayazzo M, Daniela; Cunill C, Eduardo; Vesperinas A, Gonzalo; Hamilton S, James

    2008-08-01

    The use of a dye and radiocolloid to detect sentinel lymph nodes in breast cancer increases the detection rates. However the use of either method alone does not modify the false negative rate. Therefore there is no formal contraindication for the exclusive use of dye to detect nodes. To report a prospective analysis of the exclusive blue dye technique for sentinel node biopsy in patients with early breast cancer. We analyzed the first 100 women with pathologically proven breast cancer who met the inclusion criteria. Patent blue dye was used as colorant. In the first 25 cases sentinel node was identified using radiocolloid and blue dye an then an axillary dissection performed. In the next 25 women, blue dye was used exclusively for detection and an axillary dissection was performed. In the next 50 cases, blue dye was used and only isolated sentinel node biopsy was performed. In 92 of the 100 women a sentinel node was successfully detected. In the first 50 women, the false negative rate of sentinel lymph node detection was 6.9%. No complications occurred. During follow-up, lasting three to 29 months, no axillary relapse was observed. Sentinel node biopsy in patients with early breast cancer using exclusively blue dye is feasible and safe.

  16. SPICE: Sentinel-3 Performance Improvement for Ice Sheets

    NASA Astrophysics Data System (ADS)

    McMillan, M.; Escola, R.; Roca, M.; Thibaut, P.; Aublanc, J.; Shepherd, A.; Remy, F.; Benveniste, J.; Ambrózio, A.; Restano, M.

    2017-12-01

    For the past 25 years, polar-orbiting satellite radar altimeters have provided a valuable record of ice sheet elevation change and mass balance. One of the principle challenges associated with radar altimetry comes from the relatively large ground footprint of conventional pulse-limited radars, which reduces their capacity to make measurements in areas of complex topographic terrain. In recent years, progress has been made towards improving ground resolution, through the implementation of Synthetic Aperture Radar (SAR), or Delay-Doppler, techniques. In 2010, the launch of CryoSat-2 heralded the start of a new era of SAR Interferometric (SARIn) altimetry. However, because the satellite operated in SARIn and LRM mode over the ice sheets, many of the non-interferometric SAR altimeter processing techniques have been optimized for water and sea ice surfaces only. The launch of Sentinel-3, which provides full non-interferometric SAR coverage of the ice sheets, therefore presents the opportunity to further develop these SAR processing methodologies over ice sheets. Here we present results from SPICE, a 2 year study that focuses on (1) developing and evaluating Sentinel-3 SAR altimetry processing methodologies over the Polar ice sheets, and (2) investigating radar wave penetration through comparisons of Ku- and Ka-band satellite measurements. The project, which is funded by ESA's SEOM (Scientific Exploitation of Operational Missions) programme, has worked in advance of the operational phase of Sentinel-3, to emulate Sentinel-3 SAR and pseudo-LRM data from dedicated CryoSat-2 SAR acquisitions made at the Lake Vostok, Dome C and Spirit sites in East Antarctica, and from reprocessed SARIn data in Greenland. In Phase 1 of the project we have evaluated existing processing methodologies, and in Phase 2 we are investigating new evolutions to the Delay-Doppler Processing (DDP) and retracking chains. In this presentation we (1) evaluate the existing Sentinel-3 processing chain by

  17. In vivo and ex vivo sentinel node mapping does not identify the same lymph nodes in colon cancer.

    PubMed

    Andersen, Helene Schou; Bennedsen, Astrid Louise Bjørn; Burgdorf, Stefan Kobbelgaard; Eriksen, Jens Ravn; Eiholm, Susanne; Toxværd, Anders; Riis, Lene Buhl; Rosenberg, Jacob; Gögenur, Ismail

    2017-07-01

    Identification of lymph nodes and pathological analysis is crucial for the correct staging of colon cancer. Lymph nodes that drain directly from the tumor area are called "sentinel nodes" and are believed to be the first place for metastasis. The purpose of this study was to perform sentinel node mapping in vivo with indocyanine green and ex vivo with methylene blue in order to evaluate if the sentinel lymph nodes can be identified by both techniques. Patients with colon cancer UICC stage I-III were included from two institutions in Denmark from February 2015 to January 2016. In vivo sentinel node mapping with indocyanine green during laparoscopy and ex vivo sentinel node mapping with methylene blue were performed in all patients. Twenty-nine patients were included. The in vivo sentinel node mapping was successful in 19 cases, and ex vivo sentinel node mapping was successful in 13 cases. In seven cases, no sentinel nodes were identified. A total of 51 sentinel nodes were identified, only one of these where identified by both techniques (2.0%). In vivo sentinel node mapping identified 32 sentinel nodes, while 20 sentinel nodes were identified by ex vivo sentinel node mapping. Lymph node metastases were found in 10 patients, and only two had metastases in a sentinel node. Placing a deposit in relation to the tumor by indocyanine green in vivo or of methylene blue ex vivo could only identify sentinel lymph nodes in a small group of patients.

  18. Examples of Sentinel-2A Mission Exploitation Results

    NASA Astrophysics Data System (ADS)

    Koetz, Benjamin; Hoersch, Bianca; Gascon, Ferran; Desnos, Yves-Louis; Seifert, Frank Martin; Paganini, Marc; Ramoino, Fabrizio; Arino, Olivier

    2017-04-01

    The Sentinel-2 Copernicus mission will bring significant breakthrough in the exploitation of space borne optical data. Sentinel-2 time series will transform land cover, agriculture, forestry, in-land water and costal EO applications from mapping to monitoring, from snapshot to time series data analysis, from image-based to pixel-based processing. The 5-days temporal revisiting of the Sentinel-2 satellites, when both units will be operated together, will usher us in a new era for time series analysis at high spatial resolutions (HR) of 10-20 meters. The monitoring of seasonal variations and processes in phenology and hydrology are examples of the many R&D areas to be studied. The mission's large swath and systematic acquisitions will further support unprecedented coverage at the national scale addressing information requirements of national to regional policies. Within ESA programs, such as the Data User Element (DUE), Scientific Exploitation of Operational Missions (SEOM) and Climate Change Initiative (CCI), several R&D activities are preparing the exploitation of the Sentinel-2 mission towards reliable measurements and monitoring of e.g. Essential Climate Variables and indicators for the Sustainable Development Goals. Early Sentinel-2 results will be presented related to a range of applications and scientific domains such as agricultural monitoring at national scale (DUE Sen2Agri), wetland extent and condition over African Ramsar sites (DUE GlobWetland-Africa), land cover mapping for climate change (CCI Land Cover), national land monitoring (Cadaster-Env), forest degradation (DUE ForMoSa), urban mapping (DUE EO4Urban), in-land water quality (DUE SPONGE), map of Mediterranean aquaculture (DUE SMART) and coral reef habitat mapping (SEOM S2-4Sci Coral). The above-mentioned activities are only a few examples from the very active international land imaging community building on the long-term Landsat and Spot heritage and knowledge.

  19. Sentinel-5 instrument: status of design, performance, and development

    NASA Astrophysics Data System (ADS)

    Gühne, T.; Keim, C.; Bartsch, P.; Weiß, S.; Melf, M.; Seefelder, W.

    2017-09-01

    The Sentinel-5 instrument is currently under development by a consortium led by Airbus Defence and Space in the frame of the European Union Copernicus program. It is a customer furnished item to the MetOp Second Generation satellite platform, which will provide operational meteorological data for the coming decades. Mission objective of the Sentinel-5 is to monitor the composition of the Earth atmosphere for Copernicus Atmosphere Services by taking measurements of trace gases and aerosols impacting air quality and climate with high resolution and daily global coverage. Therefore the Sentinel-5 provides five dispersive spectrometers covering the UV-VIS (270…500 nm), NIR (685 …773 nm) and SWIR (1590…1675 and 2305…2385 nm) spectral bands with resolutions <=1nm. Spatially the Sentinel-5 provides a 108° field of view with a ground sampling of 7.5 x 7 km2 at Nadir. The development program is post PDR and the build-up of the industrial team is finalised. We report on the instrument architecture and design derived from the driving requirements, the predicted instrument performance, and the general status of the program.

  20. Sentinel lymph node surgery after neoadjuvant chemotherapy in patients with T2 to T4, N0 and N1 breast cancer.

    PubMed

    Andreis, D; Bonardi, S; Allevi, G; Aguggini, S; Gussago, F; Milani, M; Strina, C; Spada, D; Ferrero, G; Ungari, M; Rocca, A; Nanni, O; Roviello, G; Berruti, A; Harris, A L; Fox, S B; Roviello, F; Polom, K; Bottini, A; Generali, D

    2016-10-01

    Histological status of axillary lymph nodes is an important prognostic factor in patients receiving surgery for breast cancer (BC). Sentinel lymph node (SLN) biopsy (B) has rapidly replaced axillary lymph node dissection (ALND), and is now the standard of care for axillary staging in patients with clinically node-negative (N0) operable BC. The aim of this study is to compare pretreatment lymphoscintigraphy with a post primary systemic treatment (PST) scan in order to reduce the false-negative rates for SLNB. In this single-institution study we considered 170 consecutive T2-4 N0-1 M0 BC patients treated with anthracycline-based PST. At the time of incisional biopsy, we performed sentinel lymphatic mapping. After PST, all patients repeated lymphoscintigraphy with the same methodology. During definitive surgery we performed further sentinel lymphatic mapping, SLNB and ALND. The SLN was removed in 158/170 patients giving an identification rate of 92.9% (95% confidence interval (CI) = 88.0-96.3%) and a false-negative rate of 14.0% (95% CI = 6.3-25.8%). SLNB revealed a sensitivity of 86.0% (95% CI = 74.2-93.7%), an accuracy of 94.9% (95% CI = 90.3-97.8%) and a negative predictive value of 92.7% (95% CI = 86.1-96.8%). Identification rate, sensitivity and accuracy are in accordance with other studies on SLNB after PST, even after clinically negative node conversion following PST. This study confirms that diagnostic biopsy and neoadjuvant chemotherapy maintain breast lymphatic drainage unaltered. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. BioSentinel: Developing a Space Radiation Biosensor

    NASA Technical Reports Server (NTRS)

    Santa Maria, Sergio R.

    2015-01-01

    BioSentinel is an autonomous fully self-contained science mission that will conduct the first study of the biological response to space radiation outside low Earth orbit (LEO) in over 40 years. The 4-unit (4U) BioSentinel biosensor system, is housed within a 6-Unit (6U) spacecraft, and uses yeast cells in multiple independent microfluidic cards to detect and measure DNA damage that occurs in response to ambient space radiation. Cell growth and metabolic activity will be measured using a 3-color LED detection system and a metabolic indicator dye with a dedicated thermal control system per fluidic card.

  2. Fluorescence-enhanced robotic radical cystectomy using unconjugated indocyanine green for pelvic lymphangiography, tumor marking, and mesenteric angiography: the initial clinical experience.

    PubMed

    Manny, Ted B; Hemal, Ashok K

    2014-04-01

    To describe the initial feasibility of fluorescence-enhanced robotic radical cystectomy (FERRC) using real-time cystoscopic injection of unconjugated indocyanine green (ICG) for tumor marking and identification of sentinel lymphatic drainage with additional intravenous injection for mesenteric angiography. Ten patients with clinically localized high-grade bladder cancer underwent FERRC. Before robot docking, rigid cystoscopy was performed, during which a 2.5-mg/mL ICG solution was injected in the bladder submucosa and detrusor circumferentially around the tumor. After robot docking, parameters describing the time course of tissue fluorescence and pelvic lymphangiography were systematically recorded. Lymphatic packets containing fluorescent lymph nodes were considered the sentinel drainage. Eight patients underwent intracorporeal ileal conduit urinary diversion, during which an additional 2-mL ICG solution was given intravenously for mesenteric angiography, allowing maximal preservation of bowel vascularity to the conduit and remaining bowel segments. Bladder tumor marking and identification of sentinel drainage were achieved in 9 of 10 (90%) patients. The area of bladder tumor was identified at a median of 15 minutes after injection, whereas sentinel drainage was visualized at a median of 30 minutes. Mesenteric angiography was successful in 8 of 8 (100%) patients at a median time of <1 minutes after intravenous injection and enabled identification of bowel arcades before intracorporeal bowel stapling. FERRC using combined cystoscopic and intravenous injection of ICG is safe and feasible. FERRC allows for reliable bladder tumor marking, identification of sentinel lymphatic drainage, and identification of mesenteric vasculature in most patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Sentinel-2A: Orbit Modelling Improvements and their Impact on the Orbit Prediction

    NASA Astrophysics Data System (ADS)

    Peter, Heike; Otten, Michiel; Fernández Sánchez, Jaime; Fernández Martín, Carlos; Féménias, Pierre

    2016-07-01

    Sentinel-2A is the second satellite of the European Copernicus Programme. The satellite has been launched on 23rd June 2015 and it is operational since mid October 2015. This optical mission carries a GPS receiver for precise orbit determination. The Copernicus POD (Precise Orbit Determination) Service is in charge of generating precise orbital products and auxiliary files for Sentinel-2A as well as for the Sentinel-1 and -3 missions. The accuracy requirements for the Sentinel-2A orbit products are not very stringent with 3 m in 3D (3 sigma) for the near real-time (NRT) orbit and 10 m in 2D (3 sigma) for the predicted orbit. The fulfilment of the orbit accuracy requirements is normally not an issue. The Copernicus POD Service aims, however, to provide the best possible orbits for all three Sentinel missions. Therefore, a sophisticated box-wing model is generated for the Sentinel-2 satellite as it is done for the other two missions as well. Additionally, the solar wing of the satellite is rewound during eclipse, which has to be modelled accordingly. The quality of the orbit prediction is dependent on the results of the orbit estimation performed before it. The values of the last estimation of each parameter is taken for the orbit propagation, i.e. estimating ten atmospheric drag coefficients per 24h, the value of the last coefficient is used as a fix parameter for the subsequent orbit prediction. The question is whether the prediction might be stabilised by, e.g. using an average value of all ten coefficients. This paper presents the status and the quality of the Sentinel-2 orbit determination in the operational environment of the Copernicus POD Service. The impact of the orbit model improvements on the NRT and predicted orbits is studied in detail. Changes in the orbit parametrization as well as in the settings for the orbit propagation are investigated. In addition, the impact of the quality of the input GPS orbit and clock product on the Sentinel-2A orbit

  4. [Sentinel node biopsy in patients with multifocal and multicentric breast cancer: A 5-year follow-up].

    PubMed

    Blanco Saiz, I; López Carballo, M T; Martínez Fernández, J; Carrión Maldonado, J; Cabrera Pereira, A; Moral Alvarez, S; Santamaría Girón, L; Cantero Cerquella, F; López Secades, A; Díaz González, D; Llaneza Folgueras, A; Aira Delgado, F J

    2014-01-01

    Sentinel lymph node biopsy (SLNB) as a staging procedure in multiple breast cancer is a controversial issue. We have aimed to evaluate the efficacy of sentinel node (SN) detection in patients with multifocal or multicentric breast cancer as well as the safety of its clinical application after a long follow-up. A prospective descriptive study was performed. Eighty-nine patients diagnosed of multiple breast cancer (73 multifocal; 16 multicentric) underwent SLNB. These patients were compared to those with unifocal neoplasia. Periareolar radiocolloid administration was performed in most of the patients. Evaluation was made at an average of 67.2 months of follow-up (32-126 months). Scintigraphic and surgical SN localization in patients with multiple breast cancer were 95.5% and 92.1%, respectively. A higher percentage of extra-axillary nodes was observed than in the unifocal group (11.7% vs 5.4%) as well as a significantly higher number of SN per patient (1.70 vs 1.38). The rate of SN localization in multicentric cancer was slightly lower than in multifocal cancer (87.5% vs 93.1%), and the finding of extra-axillary drainages was higher (20% vs 10%). Number of SN per patient was significantly higher in multicentric breast cancer (2.33 vs 1.57). No axillary relapses have been demonstrated in the follow-up in multiple breast cancer patients group. SLNB performed by periareolar injection is a reliable and accurate staging procedure of patients with multiple breast cancer, including those with multicentric processes. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  5. New Sentinel-2 radiometric validation approaches (SEOM program)

    NASA Astrophysics Data System (ADS)

    Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran

    2016-04-01

    SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range

  6. Immune response in melanoma: an in-depth analysis of the primary tumor and corresponding sentinel lymph node

    PubMed Central

    Ma, Michelle W.; Medicherla, Ratna C.; Qian, Meng; de Miera, Eleazar Vega-Saenz; Friedman, Erica B.; Berman, Russell S.; Shapiro, Richard L.; Pavlick, Anna C.; Ott, Patrick A.; Bhardwaj, Nina; Shao, Yongzhao; Osman, Iman; Darvishian, Farbod

    2013-01-01

    The sentinel lymph node is the initial site of metastasis. Down-regulation of anti-tumor immunity plays a role in nodal progression. Our objective was to investigate the relationship between immune modulation and sentinel lymph node positivity, correlating it with outcome in melanoma patients. Lymph node/primary tissues from melanoma patients prospectively accrued and followed at New York University Medical Center were evaluated for the presence of regulatory T-cells (Foxp3+) and dendritic cells (conventional: CD11c+, mature: CD86+) using immunohistochemistry. Primary melanoma immune cell profiles from sentinel lymph node-positive/-negative patients were compared. Logistic regression models inclusive of standard-of-care/immunologic primary tumor characteristics were constructed to predict the risk of sentinel lymph node positivity. Immunological responses in the positive sentinel lymph node were also compared to those in the negative non-sentinel node from the same nodal basin and matched negative sentinel lymph node. Decreased immune response was defined as increased regulatory T-cells or decreased dendritic cells. Associations between the expression of these immune modulators, clinicopathologic variables, and clinical outcome were evaluated using univariate/multivariate analyses. Primary tumor conventional dendritic cells and regression were protective against sentinel lymph node metastasis (odds ratio=0.714, 0.067; P=0.0099, 0.0816, respectively). Anti-tumor immunity was down-regulated in the positive sentinel lymph node with an increase in regulatory T-cells compared to the negative non-sentinel node from the same nodal basin (P=0.0005) and matched negative sentinel lymph node (P=0.0002). The positive sentinel lymph node also had decreased numbers of conventional dendritic cells compared to the negative sentinel lymph node (P<0.0001). Adding sentinel lymph node regulatory T-cell expression improved the discriminative power of a recurrence risk assessment model

  7. Sentinel-1 interferometry and modelling of the 2014 Fogo volcano crisis

    NASA Astrophysics Data System (ADS)

    Nikkhoo, Mehdi; Walter, Thomas R.; Prats-Iraola, Pau

    2015-04-01

    The Sentinel-1 mission is a European Space Agency's mission with the aim of earth surface monitoring on land and sea. Through the ESA project INSARAP, we aim at studying the Sentinel-1 InSAR performance for different study areas, and developing new routines for TOPS data analysis. Here we describe results achieved from Sentinel-1 acquisitions over Fogo Island, Cape Verdes. A new volcanic eruption occurred on Fogo volcano in November 2014, leading to a request for assistance communicated by the European ERCC (Emergency Response Coordination Centre). The eruption occurred after a 20 yr period of quiescence inside the Cha das Caldeiras, the embayment of a pre-historic giant landslide. The eruption affected populated areas and has lead to significant loss and destruction, forcing thousands of inhabitants to leave their homes. The timely acquisitions of Sentinel-1 data allows us the comparison of the amplitude and phase differences before and after the eruption. This is one of the first applications of Sentinel-1 data, allowing testing the system and accurate measurements of the deformation processes associated with the volcano eruption. Sentinel-1 InSAR results processed by us in ascending and descending geometry, allows developing numerical models to explain the deformation. To this aim we make use of a novel boundary element code that is based on the artifact free analytical solution of triangular dislocation elements (see Nikkhoo and Walter, 2015, Geophys. J. Int., doi:10.1093/gji/ggv035). The models consider topography and complex source geometries. We find that the magma dike is largely emplaced within the subaerial part of the volcano edifice, where the steep topography has large effects on InSAR results, the surface displacement, and the parameters of the models. Embedded in an inversion scheme, we could reproduce most of the deformation signals as determined in the Sentinel-1 InSAR data, although residuals remain in localized areas that might be associated to

  8. Distribution of Prostate Sentinel Nodes: A SPECT-Derived Anatomic Atlas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganswindt, Ute, E-mail: ute.ganswindt@med.uni-muenchen.d; Schilling, David; Mueller, Arndt-Christian

    2011-04-01

    Purpose: The randomized Radiation Therapy Oncology Group 94-13 trial revealed that coverage of the pelvic lymph nodes in high-risk prostate cancer confers an advantage (progression-free survival and biochemical failure) in patients with {>=}15% risk of lymph node involvement. To facilitate an improved definition of the adjuvant target volume, precise knowledge regarding the location of the relevant lymph nodes is necessary. Therefore, we generated a three-dimensional sentinel lymph node atlas. Methods and Materials: In 61 patients with high-risk prostate cancer, a three-dimensional visualization of sentinel lymph nodes was performed using a single photon emission computed tomography system after transrectal intraprostatic injectionmore » of 150 to 362 (median 295) mega becquerel (MBq) {sup 99m}Technetium-nanocolloid (1.5-3h after injection) followed by an anatomic functional image fusion. Results: In all, 324 sentinel nodes in 59 of 61 patients (96.7%) were detected, with 0 to 13 nodes per patient (median 5, mean 5.3). The anatomic distribution of the sentinel nodes was as follows: external iliac 34.3%, internal iliac 17.9%, common iliac 12.7%, sacral 8.6%, perirectal 6.2%, left paraaortic 5.3%, right paraaortic 5.3%, seminal vesicle lymphatic plexus 3.1%, deep inguinal 1.5%, superior rectal 1.2%, internal pudendal 1.2%, perivesical 0.9%, inferior rectal 0.9%, retroaortic 0.3%, superficial inguinal 0.3%, and periprostatic 0.3%. Conclusions: The distribution of sentinel nodes as detected by single photon emission computed tomography imaging correlates well with the distribution determined by intraoperative gamma probe detection. A lower detection rate of sentinels in close proximity to the bladder and seminal vesicles is probably caused by the radionuclide accumulation in the bladder. In regard to intensity-modulated radiotherapy techniques, the presented anatomic atlas may allow optimized target volume definitions.« less

  9. Assimilation of Sentinel-1 and SMAP observations to improve GEOS-5 soil moisture

    NASA Astrophysics Data System (ADS)

    Lievens, Hans; Reichle, Rolf; Wagner, Wolfgang; De Lannoy, Gabrielle; Liu, Qing; Verhoest, Niko

    2017-04-01

    The SMAP (Soil Moisture Active and Passive) mission carries an L-band radiometer that provides brightness temperature observations at a nominal resolution of 40 km. These radiance observations are routinely assimilated into GEOS-5 (Goddard Earth Observing System version 5) to generate the SMAP Level 4 Soil Moisture product. The use of C-band radar backscatter observations from Sentinel-1 has the potential to add value to the radiance assimilation by increasing the level of spatial detail. The specifications of Sentinel-1 are appealing, particularly its high spatial resolution (5 by 20 m in interferometric wide swath mode) and frequent revisit time (potentially every 3 days for the Sentinel-1A and Sentinel-1B constellation). However, the shorter wavelength of Sentinel-1 observations implies less sensitivity to soil moisture. This study investigates the value of Sentinel-1 data for hydrologic simulations by assimilating the radar observations into GEOS-5, either separately from or simultaneously with SMAP radiometer observations. The assimilation can be performed if either or both Sentinel-1 or SMAP observations are available, and is thus not restricted to synchronised overpasses. To facilitate the assimilation of the radar observations, GEOS-5 is coupled to the water cloud model, simulating the radar backscatter as observed by Sentinel-1. The innovations, i.e. differences between observations and simulations, are converted into increments to the model soil moisture state through an Ensemble Kalman Filter. The model runs are performed at 9-km spatial and 3-hourly temporal resolution, over the period from May 2015 to October 2016. The impact of the assimilation on surface and root-zone soil moisture simulations is assessed using in situ measurements from SMAP core validation sites and sparse networks. The assimilation of Sentinel-1 backscatter is found to consistently improve surface and root-zone soil moisture, relative to the open loop (no assimilation). However

  10. Evaluation of registration accuracy between Sentinel-2 and Landsat 8

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Cuca, Branka; Previtali, Mattia

    2016-08-01

    Starting from June 2015, Sentinel-2A is delivering high resolution optical images (ground resolution up to 10 meters) to provide a global coverage of the Earth's land surface every 10 days. The planned launch of Sentinel-2B along with the integration of Landsat images will provide time series with an unprecedented revisit time indispensable for numerous monitoring applications, in which high resolution multi-temporal information is required. They include agriculture, water bodies, natural hazards to name a few. However, the combined use of multi-temporal images requires an accurate geometric registration, i.e. pixel-to-pixel correspondence for terrain-corrected products. This paper presents an analysis of spatial co-registration accuracy for several datasets of Sentinel-2 and Landsat 8 images distributed all around the world. Images were compared with digital correlation techniques for image matching, obtaining an evaluation of registration accuracy with an affine transformation as geometrical model. Results demonstrate that sub-pixel accuracy was achieved between 10 m resolution Sentinel-2 bands (band 3) and 15 m resolution panchromatic Landsat images (band 8).

  11. A first assessment of Sentinel-3 SAR altimetry over ice sheets

    NASA Astrophysics Data System (ADS)

    McMillan, M.; Muir, A. S.; Shepherd, A.

    2017-12-01

    The first Sentinel-3 satellite was launched in 2016 and carries onboard a Ku-band Synthetic Aperture Radar (SAR) altimeter. With coverage up to a latitude of 81.5 degrees and a repeat period of 27 days, it offers the opportunity to measure surface topography and elevation change across much of the Antarctic and Greenland Ice Sheets, therefore continuing the existing 25 year radar altimeter record. The global operation of Sentinel-3 in SAR mode differs from all past Ku-band instruments; for the first time SAR measurements are routinely acquired across the interiors of the ice sheets; however unlike CryoSat-2 it does not carry an interferometer to aid signal retrieval in regions of complex coastal terrain. In view of these differences and the novel characteristics of the Sentinel-3 system, assessments of the performance of the instrument are required, to evaluate the satellite's utility for monitoring Earth's Polar regions. Here, we analyse data acquired during the first year of routine operations, to assess the performance of the Sentinel-3 SAR altimeter to date. We focus both on inland ice sheet regions, where Sentinel-3 provides the first operational SAR altimeter measurements, and also on coastal areas with more complex topography. We investigate SAR waveforms and retrieved elevations in both regions, and through comparison to measurements from earlier missions examine the impact of the different modes of operation. We also conduct a high level evaluation of the data, by comparing it to reference airborne altimetry, to provide an assessment of Sentinel-3 performance to date over ice sheets.

  12. RTS effect detection in Sentinel-4 data

    NASA Astrophysics Data System (ADS)

    Candeias, Henrique; Gnata, Xavier; Harlander, Maximilian; Hermsen, Markus; Hohn, Rüdiger; Riedl, Stefan; Skegg, Michael; Williges, Christian; Reulke, Ralf

    2017-09-01

    The future ESA Earth Observation Sentinel-4/UVN is a high resolution spectrometer intended to fly on board a Meteosat Third Generation Sounder (MTG-S) platform, placed in a geostationary orbit. The main objective of this optical mission is to continuously monitor the air quality over Europe in near-real time. The Sentinel-4/UVN instrument operates in three wavelength bands: Ultraviolet (UV: 305-400 nm), Visible (VIS: 400- 500 nm) and Near-infrared (NIR: 750-775 nm). Two dedicated CCD detector have been developed to be used in the Focal Plane Subsystems (FPS), one for the combined UV and VIS band, the other covering the NIR band. Being a high resolution spectrometer with challenging radiometric accuracy requirements, both on spectral and spatial dimensions, an effect such the Random Telegraph Signal (RTS) can represent a relevant contribution for the complete system accuracy. In this work we analyze the RTS effect on data acquired during the FPS testing campaign with qualification models for the Sentinel-4/UVN detectors. This test campaign has been performed in late 2016. The strategy for the impact assessment of RTS is to measure the effect at room temperature and then to extrapolate the results to the at instrument operational temperature. This way, very-long lasting data acquisitions could be avoided since the RTS frequency is much lower at cryogenic temperatures. A reliable technique for RTS effect detection has been developed in order to characterize the signal levels amplitude and occurrence frequencies (flipping rate). We demonstrate the residual impact of the RTS on the global In-Orbit Sentinel-4/UVN instrument performance and products accuracy.

  13. Sentinel-2: presentation of the CAL/VAL commissioning phase

    NASA Astrophysics Data System (ADS)

    Trémas, Thierry L.; Déchoz, Cécile; Lacherade, Sophie; Nosavan, Julien; Petrucci, Beatrice

    2015-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) has developed the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbits. Sentinel-2 will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). The first sentinel 2A has been launched on June 22nd, 2015, from Kourou, French Guyana. In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to insure the cal/val commissioning phase, for Image Quality aspects. This paper provides first, an overview of the Sentinel-2 system after the launch. Then the articles focuses on the means implemented and activated in CNES to perform the In Orbit Commissioning, the availability and performances of the different devices involved in the ground segment : the GPP in charge of producing the level 1 files, the "radiometric unit" that processes sensitivity parameters, the "geometric unit" in charge of fitting the images on a reference map, MACCS that will produce Level 2A files (computing reflectances at the Bottom of Atmosphere) and the TEC-S2 that will coordinate all the previous software and drive a database in which will be gather the incoming Level 0 files and the processed Level 1 files.

  14. Prairie Pothole Region wetlands and subsurface drainage systems: Key factors for determining drainage setback distances

    USGS Publications Warehouse

    Tangen, Brian; Wiltermuth, Mark T.

    2018-01-01

    Use of agricultural subsurface drainage systems in the Prairie Pothole Region of North America continues to increase, prompting concerns over potential negative effects to the Region's vital wetlands. The U.S. Fish and Wildlife Service protects a large number of wetlands through conservation easements that often utilize standard lateral setback distances to provide buffers between wetlands and drainage systems. Because of a lack of information pertaining to the efficacy of these setback distances for protecting wetlands, information is required to support the decision making for placement of subsurface drainage systems adjacent to wetlands. We used qualitative graphical analyses and data comparisons to identify characteristics of subsurface drainage systems and wetland catchments that could be considered when assessing setback distances. We also compared setback distances with catchment slope lengths to determine if they typically exclude drainage systems from the catchment. We demonstrated that depth of a subsurface drainage system is a key factor for determining drainage setback distances. Drainage systems located closer to the surface (shallow) typically could be associated with shorter lateral setback distances compared with deeper systems. Subsurface drainage systems would be allowed within a wetland's catchment for 44–59% of catchments associated with wetland conservation easements in North Dakota. More specifically, results suggest that drainage setback distances generally would exclude drainage systems from catchments of the smaller wetlands that typically have shorter slopes in the adjacent upland contributing area. For larger wetlands, however, considerable areas of the catchment would be vulnerable to drainage that may affect wetland hydrology. U.S. Fish and Wildlife Service easements are associated with > 2,000 km2 of wetlands in North Dakota, demonstrating great potential to protect these systems from drainage depending on policies for installing

  15. Early Validation of Sentinel-2 L2A Processor and Products

    NASA Astrophysics Data System (ADS)

    Pflug, Bringfried; Main-Knorn, Magdalena; Bieniarz, Jakub; Debaecker, Vincent; Louis, Jerome

    2016-08-01

    Sentinel-2 is a constellation of two polar orbiting satellite units each one equipped with an optical imaging sensor MSI (Multi-Spectral Instrument). Sentinel-2A was launched on June 23, 2015 and Sentinel-2B will follow in 2017.The Level-2A (L2A) processor Sen2Cor implemented for Sentinel-2 data provides a scene classification image, aerosol optical thickness (AOT) and water vapour (WV) maps and the Bottom-Of-Atmosphere (BOA) corrected reflectance product. First validation results of Sen2Cor scene classification showed an overall accuracy of 81%. AOT at 550 nm is estimated by Sen2Cor with uncertainty of 0.035 for cloudless images and locations with dense dark vegetation (DDV) pixels present in the image. Aerosol estimation fails if the image contains no DDV-pixels. Mean difference between Sen2Cor WV and ground-truth is 0.29 cm. Uncertainty of up to 0.04 was found for the BOA- reflectance product.

  16. Impact of false-negative sentinel lymph node biopsy on survival in patients with cutaneous melanoma.

    PubMed

    Caracò, C; Marone, U; Celentano, E; Botti, G; Mozzillo, N

    2007-09-01

    Sentinel lymph node biopsy is widely accepted as standard care in melanoma despite lack of pertinent randomized trials results. A possible pitfall of this procedure is the inaccurate identification of the sentinel lymph node leading to biopsy and analysis of a nonsentinel node. Such a technical failure may yield a different prognosis. The purpose of this study is to analyze the incidence of false negativity and its impact on clinical outcome and to try to understand its causes. The Melanoma Data Base at National Cancer Institute of Naples was analyzed comparing results between false-negative and tumor-positive sentinel node patients focusing on overall survival and prognostic factors influencing the clinical outcome. One hundred fifty-one cases were diagnosed to be tumor-positive after sentinel lymph node biopsy and were subjected to complete lymph node dissection. Thirty-four (18.4%)patients with tumor-negative sentinel node subsequently developed lymph node metastases in the basin site of the sentinel procedure. With a median follow-up of 42.8 months the 5-year overall survival was 48.4% and 66.3% for false-negative and tumor-positive group respectively with significant statistical differences (P < .03). The sensitivity of sentinel lymph node biopsy was 81.6%, and a regional nodal basin recurrence after negative-sentinel node biopsy means a worse prognosis, compared with patients submitted to complete lymph node dissection after a positive sentinel biopsy. The evidence of higher number of tumor-positive nodes after delayed lymphadenectomy in false-negative group compared with tumor-positive sentinel node cases, confirmed the importance of an early staging of lymph nodal involvement. Further data will better clarify the role of prognostic factors to identify cases with a more aggressive biological behavior of the disease.

  17. Simplified intraoperative sentinel-node detection performed by the urologist accurately determines lymph-node stage in prostate cancer.

    PubMed

    Kjölhede, Henrik; Bratt, Ola; Gudjonsson, Sigurdur; Sundqvist, Pernilla; Liedberg, Fredrik

    2015-04-01

    The reference standard for lymph-node staging in prostate cancer is currently an extended pelvic lymph-node dissection (ePLND), which detects most, but not all, regional lymph-node metastases. As an alternative to ePLND, sentinel-node dissection with preoperative isotope injection and imaging has been reported. The objective was to determine whether intraoperative sentinel-node detection with a simplified protocol can accurately determine lymph-node stage in prostate cancer patients. Patients with biopsy-verified high-risk prostate cancer with tumour stage T2-3 were included in the study. All patients underwent both ePLND and sentinel-node detection. (99m)Tc-marked nanocolloid was injected peritumourally by the operating urologist after induction of anaesthesia just before surgery. Sentinel nodes were detected both in vivo and ex vivo intraoperatively using a gamma probe. Sentinel nodes and metastases and their locations were recorded. Sensitivity and specificity were calculated. At least one sentinel node was detected in 72 (87%) of the 83 patients. In 13 (18%) of these 72 patients sentinel nodes were detected outside the ePLND template. In six of these 13 patients, the Sentinel nodes from outside the template contained metastases, which proved to be the only metastases in two. For 12 patients the only metastatic deposit found was a micrometastasis (≤2 mm) in a sentinel node. In the 72 patients with detectable sentinel nodes, pathological analysis of the sentinel node correctly categorized 71 and ePLND 70 patients. This protocol yielded results comparable to the commonly used technique of sentinel-node detection, but with more cases of non-detection.

  18. Contrast-enhanced ultrasound mapping of sentinel lymph nodes in oral tongue cancer-a pilot study.

    PubMed

    Gvetadze, Shalva R; Xiong, Ping; Lv, Mingming; Li, Jun; Hu, Jingzhou; Ilkaev, Konstantin D; Yang, Xin; Sun, Jian

    2017-03-01

    To assess the usefulness of contrast-enhanced ultrasound (CEUS) with peritumoral injection of microbubble contrast agent for detecting the sentinel lymph nodes for oral tongue carcinoma. The study was carried out on 12 patients with T1-2cN0 oral tongue cancer. A radical resection of the primary disease was planned; a modified radical supraomohyoid neck dissection was reserved for patients with larger lesions (T2, n = 8). The treatment plan and execution were not influenced by sentinel node mapping outcome. The Sonovue ™ contrast agent (Bracco Imaging, Milan, Italy) was utilized. After detection, the position and radiologic features of the sentinel nodes were recorded. The identification rate of the sentinel nodes was 91.7%; one patient failed to demonstrate any enhanced areas. A total of 15 sentinel nodes were found in the rest of the 11 cases, with a mean of 1.4 nodes for each patient. The sentinel nodes were localized in: Level IA-1 (6.7%) node; Level IB-11 (73.3%) nodes; Level IIA-3 (20.0%) nodes. No contrast-related adverse effects were observed. For oral tongue tumours, CEUS is a feasible and potentially widely available approach of sentinel node mapping. Further clinical research is required to establish the position of CEUS detection of the sentinel nodes in oral cavity cancers.

  19. Availability of sentinel lymph node biopsy for cutaneous squamous cell carcinoma.

    PubMed

    Maruyama, Hiroshi; Tanaka, Ryota; Fujisawa, Yasuhiro; Nakamura, Yasuhiro; Ito, Shusaku; Fujimoto, Manabu

    2017-04-01

    Cutaneous squamous cell carcinoma is the second common cutaneous cancer, especially in the elderly. Sentinel lymph node biopsy is generally performed in breast cancers and cutaneous melanomas to detect occult nodal metastases. The benefit of sentinel lymph node biopsy in improving cutaneous squamous cell carcinoma prognosis is doubtful. One hundred and sixty-nine patients who underwent treatment for cutaneous squamous cell carcinoma between 2004 and 2015, and who were followed up for at least 6 months or developed metastases within the follow-up period were included. Forty-nine patients underwent sentinel lymph node biopsy, whereas 120 patients did not, including 13 who exhibited clinical lymph node metastases before treatment. Of these 49 patients, nine (18.4%) presented with sentinel lymph node metastasis, which occurred after treatment in three (6.1%) of them (false-negative). Among the 107 patients who did not undergo lymph node biopsy, 12 (11.2%) developed post-treatment metastases. The metastasis-free and disease-specific survival rates were not significantly different in those who did or did not undergo sentinel lymph node biopsy. Patients with clinical lymph node metastases had a higher risk compared with those without. Patients with T2-T4 tumors had a higher risk compared with those with T1 tumors. When selecting for those with T2 tumors or greater, the same lack of relationship was observed. In conclusion, in this small retrospective cohort, in patients with cutaneous squamous cell carcinoma, there were no significant differences in metastasis-free and disease-specific survival rates between those who did or did not undergo sentinel lymph node biopsy, regardless of T staging. © 2016 Japanese Dermatological Association.

  20. The Value of Sentinel Lymph Node Biopsy in Oral Cavity Cancers

    PubMed Central

    Kaya, İsa; Göde, Sercan; Öztürk, Kerem; Turhal, Göksel; Aliyev, Araz; Akyıldız, Serdar; Duygun, Ülkem Yararbaş; Uluöz, Ümit; Yavuzer, Atilla

    2015-01-01

    Objective The aim of this study was to establish the effectiveness of sentinel lymph node biopsy in the detection of metastasis in N0 necks of T1–T2 early-stage oral cavity cancers. Materials and Methods Twenty neck dissections were performed in 18 patients diagnosed with T1 and T2 oral cavity cancer, with an indication for elective neck dissection between November 2007 and January 2011. The male to female ratio was 12:8, with a mean age of 54.5 years (range 28–76). Eight of the dissections were performed for lower lip cancer, 7 for tongue cancer, and 5 for floor of the mouth cancer. Sentinel lymph node biopsy was used to detect metastatic lymph nodes. Tc99m radionuclide injection was administered to the periphery of the tumor 24 h before the operation, and a lymphoscintigraphy image was obtained 30 min after the injection. Sentinel lymph nodes were localized and excised on the day of surgery using static lymphoscintigraphy images and a gamma probe. Sentinel lymph nodes were sent for a frozen section examination, and either a selective or a comprehensive neck dissection was performed for each neck according to the results. Results After the final histopathological examination of the specimens, the negative predictive value, the positive predictive value, the accuracy of the sentinel lymph node biopsy, and frozen section accuracy were found to be 100%. Conclusion Sentinel lymph node biopsy was found to be an efficient method in the pathological staging and management of the N0 neck in early T-stage oral cavity cancers. PMID:29391982

  1. Altimeter products for the Sentinel-6/Jason-CS mission

    NASA Astrophysics Data System (ADS)

    Scharroo, Remko; Bonekamp, Hans; Ponsard, Christelle; Nogueira Loddo, Carolina

    2015-04-01

    The Sentinel-6 (Jason-CS) mission will be unique in the Jason-series of altimeters. It will be the first of the "reference missions" outfitted with a SAR altimeter. Not only that, it will be the first altimeter that operates in a continuous high-rate pulse mode, such that there is no longer the need to wait 2/3 of the time for pulses to be received, while transmitting only 1/3 of the time, like the altimeters of CryoSat-2 and Sentinel-3. On top of that, Sentinel-6 will be operating in this mode 100% of the time. This particular operating mode allows simultaneous production of low-resolution mode (LRM) measurements on-board as well as the processing of SAR echoes on-ground. Both types of measurements will be provided in (separate) Sentinel-6 altimeter data products. The data chain for Jason-CS foresees to have a number of products similar to those of Sentinel-3, while at the same time trying to maintain a good coherency with the Jason-1 and Jason-2 product tree. The aim is to provide near-realtime (NRT) products compatible with those of the previous missions while at the same time providing slow-time-critical (STC) and non-time-critical (NTC) products with all of the variables needed to fully exploit and analyse the SAR mode data. Similar to the Jason-1/2 products will be produced with three different latencies (3-5 hours, 1-2 days, 60 days) and three levels of complexities (1-Hz data, 1-Hz and 20-Hz data, 1-Hz and 20-Hz data and waveforms). On top of that, Level 1 products will be released containing all the individual echoes in the time domain (L1A) or the measurement data and waveforms without geophysical corrections (L1B). A L1B-S product, with the individual waveforms stacked and geo-located such as is available for Sentinel-3 is under consideration. This poster will provide an overview of the suggested data products and invites users to give their feedback on the proposed data delivery and data formats.

  2. Bibliography for acid-rock drainage and selected acid-mine drainage issues related to acid-rock drainage from transportation activities

    USGS Publications Warehouse

    Bradley, Michael W.; Worland, Scott C.

    2015-01-01

    Acid-rock drainage occurs through the interaction of rainfall on pyrite-bearing formations. When pyrite (FeS2) is exposed to oxygen and water in mine workings or roadcuts, the mineral decomposes and sulfur may react to form sulfuric acid, which often results in environmental problems and potential damage to the transportation infrastructure. The accelerated oxidation of pyrite and other sulfidic minerals generates low pH water with potentially high concentrations of trace metals. Much attention has been given to contamination arising from acid mine drainage, but studies related to acid-rock drainage from road construction are relatively limited. The U.S. Geological Survey, in cooperation with the Tennessee Department of Transportation, is conducting an investigation to evaluate the occurrence and processes controlling acid-rock drainage and contaminant transport from roadcuts in Tennessee. The basic components of acid-rock drainage resulting from transportation activities are described and a bibliography, organized by relevant categories (remediation, geochemical, microbial, biological impact, and secondary mineralization) is presented.

  3. Sentinel 2B: the image quality performances at the beginning of the mission

    NASA Astrophysics Data System (ADS)

    Trémas, T.; Lonjou, V.; Dick, A.; Languille, F.; Gaudel-Vacaresse, A.; Vidal, B.; Revel, C.

    2017-09-01

    Launched on March 6th, 2017 from Kourou, Sentinel 2B has passed the phase of commissioning. Sentinel 2B will work together with Sentinel 2A launched in June 2015. The building and implementation of the satellite has been made under the responsibility of ESA, for the European Commission. The subset of Image Quality commissioning was delegated by ESA to CNES, referring to the experience of the French Space Agency on previous imagers. This phase lasted 4 months after the launch, a little longer than the formal In Orbit Calibration period conducted by ESA, some Image Quality parameters requiring several months before converging to a stable state. This paper presents the status of the satellite, from an IQ prospective, just before it entered its operational phase. The radiometric and geometric performances are listed, including: the absolute radiometric calibration, the equalization, the SNR, the absolute and the multi-temporal location accuracy. The performances of both satellites Sentinel and Sentinel 2B working together, will be addressed. A particular focus will be done on multi-temporal location performances, homogeneity of radiometric inter calibrations. The accomplishment of the Global Reference Image over Europe is evoked as well. The IQ commissioning phase ended on June 2017. From this date, the monitoring of IQ parameters is under the responsibility of ESA/ESRIN. Nevertheless, CNES continues to support ESA to survey the accuracy of S2A and S2B performances. The article ends by dealing with the prospective offered by the couple Sentinel 2A + Sentinel 2B.

  4. Atmospheric CO2 sequestration in iron and steel slag: Consett, Co. Durham, UK.

    PubMed

    Mayes, William Matthew; Riley, Alex L; Gomes, Helena I; Brabham, Peter; Hamlyn, Joanna; Pullin, Huw; Renforth, Phil

    2018-06-12

    Carbonate formation in waste from the steel industry could constitute a non-trivial proportion of global requirements to remove carbon dioxide from the atmosphere at potentially low cost. To constrain this potential, we examined atmospheric carbon dioxide sequestration in a >20 million tonne legacy slag deposit in northern England, UK. Carbonates formed from the drainage water of the heap had stable carbon and oxygen isotopes between -12 and -25 ‰ and -5 and -18 ‰ for δ13C and δ18O respectively, suggesting atmospheric carbon dioxide sequestration in high pH solutions. From analysis of solution saturation state, we estimate that between 280 and 2,900 tCO2 have precipitated from the drainage waters. However, by combining a thirty-seven-year dataset of the drainage water chemistry with geospatial analysis, we estimate that <1 % of the maximum carbon capture potential of the deposit may have been realised. This implies that uncontrolled deposition of slag is insufficient to maximise carbon sequestration, and there may be considerable quantities of unreacted legacy deposits available for atmospheric carbon sequestration.

  5. Sentinel-2 ArcGIS Tool for Environmental Monitoring

    NASA Astrophysics Data System (ADS)

    Plesoianu, Alin; Cosmin Sandric, Ionut; Anca, Paula; Vasile, Alexandru; Calugaru, Andreea; Vasile, Cristian; Zavate, Lucian

    2017-04-01

    This paper addresses one of the biggest challenges regarding Sentinel-2 data, related to the need of an efficient tool to access and process the large collection of images that are available. Consequently, developing a tool for the automation of Sentinel-2 data analysis is the most immediate need. We developed a series of tools for the automation of Sentinel-2 data download and processing for vegetation health monitoring. The tools automatically perform the following operations: downloading image tiles from ESA's Scientific Hub or other venders (Amazon), pre-processing of the images to extract the 10-m bands, creating image composites, applying a series of vegetation indexes (NDVI, OSAVI, etc.) and performing change detection analyses on different temporal data sets. All of these tools run in a dynamic way in the ArcGIS Platform, without the need of creating intermediate datasets (rasters, layers), as the images are processed on-the-fly in order to avoid data duplication. Finally, they allow complete integration with the ArcGIS environment and workflows

  6. Stormwater Drainage Wells

    EPA Pesticide Factsheets

    Provides information for identifying stormwater drainage wells, learn how to comply with regulations for storm water drainage wells, and how to reduce the threat to ground water from stormwater injection wells.

  7. Urine drainage bags

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000142.htm Urine drainage bags To use the sharing features on this page, please enable JavaScript. Urine drainage bags collect urine. Your bag will attach ...

  8. Snow Cover Mapping and Ice Avalanche Monitoring from the Satellite Data of the Sentinels

    NASA Astrophysics Data System (ADS)

    Wang, S.; Yang, B.; Zhou, Y.; Wang, F.; Zhang, R.; Zhao, Q.

    2018-04-01

    In order to monitor ice avalanches efficiently under disaster emergency conditions, a snow cover mapping method based on the satellite data of the Sentinels is proposed, in which the coherence and backscattering coefficient image of Synthetic Aperture Radar (SAR) data (Sentinel-1) is combined with the atmospheric correction result of multispectral data (Sentinel-2). The coherence image of the Sentinel-1 data could be segmented by a certain threshold to map snow cover, with the water bodies extracted from the backscattering coefficient image and removed from the coherence segment result. A snow confidence map from Sentinel-2 was used to map the snow cover, in which the confidence values of the snow cover were relatively high. The method can make full use of the acquired SAR image and multispectral image under emergency conditions, and the application potential of Sentinel data in the field of snow cover mapping is exploited. The monitoring frequency can be ensured because the areas obscured by thick clouds are remedied in the monitoring results. The Kappa coefficient of the monitoring results is 0.946, and the data processing time is less than 2 h, which meet the requirements of disaster emergency monitoring.

  9. Clinical relevance of sentinel lymph node status examined with conventional histology and molecular biology.

    PubMed

    Micciolo, Rocco; Boi, Sebastiana; Paoli, Loredana; Cristofolini, Paolo; Girlando, Salvatore; Dalla Palma, Paolo; Cristofolini, Mario

    2009-01-01

    The presence of nodal metastases in patients with primary cutaneous melanoma adversely affects the biological behavior and is related to a poor prognosis. The role of sentinel lymph node biopsy is still debated. The aim of this study was to evaluate the prognostic role of sentinel lymph node biopsy with respect to disease-free period and overall survival. Patients with invasive cutaneous melanoma who underwent sentinel lymph node biopsy in the Santa Chiara Hospital of Trento between October 1997 and December 2002 were evaluated. The lymph nodes were examined with conventional histology, S100 and tyrosinase in immunohistochemistry, and tyrosinase in molecular biology. There were 144 patients with 198 sentinel lymph nodes. A significant association was found in conventional histology with Clark level and Breslow thickness. The prognostic role of sentinel lymph node status was independent of the other considered variables. However, no significant association was found with the molecular biology test. A significant excess of positive results at molecular biology was found. Sentinel lymph node biopsy is an important independent prognostic factor for invasive cutaneous melanoma, but only when evaluated with conventional histology. As a result of this study, we stopped performing the tyrosinase test in molecular biology.

  10. Remarks on Sentinel-1 Avionic SW Qualification

    NASA Astrophysics Data System (ADS)

    Candia, Sante; Pascucci, Dario

    2013-08-01

    The GMES Sentinel-1 Earth Radar Observatory, a projects co-funded by the European Union and the European Space Agency (ESA), is a constellation of C-band radar satellites. The satellites have been conceived to be a continuous and reliable source of C-band SAR imagery for operational application such as mapping of global landmasses, coastal zones and monitoring of shipping routes. ESA is responsible for the development of the Sentinel-1 satellites that are built by an industrial consortium headed by Thales Alenia Space Italy (TASI) as Prime Contractor. TAS-I is also directly responsible for the production of the Spacecraft Bus and the Avionic S/S including the Avionic SW (ASW), which is characterized by: · The high performances of its attitude and orbit determination and control function; · Scheduling of the imaging activity on position basis with high geo-location performances; · High on board autonomy both in routine and contingency situations. This paper is focused on the Sentinel-1 Avionic SW, which has currently been qualified by TAS-I for Flight. It covers both the SW architecture and development process areas: · Avionic SW context; · Avionic SW architecture; · Flexibility of PUS-based on-board autonomy and FDIR; · Validation and Qualification activities;

  11. [Relevance of the sentinel lymph node biopsy in breast multifocal and multicentric cancer].

    PubMed

    Mosbah, R; Raimond, E; Pelissier, A; Hocedez, C; Graesslin, O

    2015-05-01

    The sentinel lymph node biopsy is a gold standard in the management of breast cancer. Its role in multifocal or multicentric tumors is still evolving. The aim of this study is to assess the feasibility and pertinence of sentinel lymph node biopsy in multifocal and multicentric tumors based on a systematic review of literature. A systematic review was conducted searching in the following electronic databases PubMed using "sentinel lymph node biopsy", "breast cancer", "multifocal tumor", "multicentric tumor" and "multiple tumor" as keywords. We included original articles published between 2000 and 2014, both French and English, studying feasibility of sentinel lymph node biopsy in invasive breast cancer, multicentric and/or multifocal tumors. The first end point was success rate and false negative rate. Twenty-six articles were included in this literature review, with 2212 cases (782 multifocal, 737 multicentric and 693 multiple tumors). Percentage of tumors whose stage was higher than stage T2 ranged from 0 to 86.3%. Success rate average was 83.1%. False negative average was 8.2%. False negative rate was less than 10% in 15 articles. Mean of sentinel lymph node biopsy was 2 (1-9). The average rate of sentinel lymph node positive was 50.6%. Axillary recurrence rate was 0.5%. Despite the methodological biases of the studies included in this review of literature, the false negative rate of sentinel node biopsy in multifocal and multicentric breast cancers are less than 10% with a low rate of axillary recurrence. Despite the lack of randomized study, this procedure can be routinely performed in accordance with rigorous technical process. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. Predictors of sentinel lymph node metastases in breast cancer-radioactivity and Ki-67.

    PubMed

    Thangarajah, Fabinshy; Malter, Wolfram; Hamacher, Stefanie; Schmidt, Matthias; Krämer, Stefan; Mallmann, Peter; Kirn, Verena

    2016-12-01

    Since the introduction of the sentinel node technique for breast cancer in the 1990s patient's morbidity was reduced. Tracer uptake is known to be dependent from lymph node integrity and activity of macrophages. The aim of this study was to assess whether radioactivity of the tracer can predict sentinel lymph node metastases. Furthermore, a potential association with Ki-67 index was examined. Non-invasive prediction of lymph node metastases could lead to a further decrease of morbidity. We retrospectively analyzed patients with primary breast cancer who underwent surgery at the Department of Obstetrics and Gynecology in the University Hospital of Cologne between 2012 and 2013. Injection of radioactive tracer was done a day before surgery in the department of Nuclear Medicine. Clinical data and radioactivity of the sentinel node measured the day before and intraoperatively were abstracted from patient's files. Of 246 patients, 64 patients had at least one, five patients had two and one patient had three positive sentinel lymph nodes. Occurrence of sentinel lymph node metastases was not associated with preoperative tracer activity (p = 0,319), intraoperative tracer activity of first sentinel node (p = 0,086) or with loss of tracer activity until operation (p = 0,909). There was no correlation between preoperative Ki-67 index and occurrence of lymph node metastases (p = 0,403). In our cohort, there was no correlation between radioactivity and sentinel node metastases. Tracer uptake might not only be influenced by lymph node metastases and does not predict metastatic lymph node involvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Laboratory-supported influenza surveillance in Victorian sentinel general practices.

    PubMed

    Kelly, H; Murphy, A; Leong, W; Leydon, J; Tresise, P; Gerrard, M; Chibo, D; Birch, C; Andrews, R; Catton, M

    2000-12-01

    Laboratory-supported influenza surveillance is important as part of pandemic preparedness, for identifying and isolating candidate vaccine strains, for supporting trials of anti-influenza drugs and for refining the influenza surveillance case definition in practice. This study describes the implementation of laboratory-supported influenza surveillance in Victorian sentinel general practices and provides an estimate of the proportion of patients with an influenza-like illness proven to have influenza. During 1998 and 1999, 25 sentinel general practices contributed clinical surveillance data and 16 metropolitan practices participated in laboratory surveillance. Serological, virus-antigen detection, virus culture and multiplex polymerase chain reaction procedures were used to establish the diagnosis of influenza. Two laboratories at major teaching hospitals in Melbourne provided additional data on influenza virus identification. General practice sentinel surveillance and laboratory identification of influenza provided similar data on the pattern of influenza in the community between May and September. The clinical suspicion of influenza was confirmed in 49 to 54 per cent of cases seen in general practice.

  14. Are there still roles for exocrine bladder drainage and portal venous drainage for pancreatic allografts?

    PubMed

    Young, Carlton J

    2009-02-01

    Controversy remains regarding the best methodology of handling exocrine pancreatic fluid and pancreatic venous effluent. Bladder drainage has given way to enteric drainage. However, is there an instance in which bladder drainage is preferable? Also, hyperinsulinemia, as a result of systemic venous drainage (SVD), is claimed to be proatherosclerotic, whereas portal venous drainage (PVD) is more physiologic and less atherosclerotic. Bladder drainage remains a viable method of exocrine pancreas drainage, but evidence is sparse that measuring urinary amylase has a substantial benefit in the early detection of acute rejection in all types of pancreas transplants. Currently, there is no incontrovertible evidence that systemic hyperinsulinemia is proatherosclerotic, whereas recent metabolic studies on SVD and PVD showed that there was no benefit to PVD. Given the advent of newer immunosuppressive agents and overall lower acute rejection rates, the perceived benefit of bladder drainage as a means to measure urinary amylase as an early marker of rejection has not been substantiated. However, there may be a selective role for bladder drainage in 'high risk' pancreases. Also, without a clear-cut metabolic benefit to PVD over SVD, it remains the surgeon's choice as to which method to use.

  15. Sentinel-4: the geostationary component of the GMES atmosphere monitoring missions

    NASA Astrophysics Data System (ADS)

    Bazalgette Courrèges-Lacoste, G.; Arcioni, M.; Meijer, Y.; Bézy, J.-L.; Bensi, P.; Langen, J.

    2017-11-01

    The implementation of operational atmospheric composition monitoring missions is foreseen in the context of the Global Monitoring for Environment and Security (GMES) initiative. Sentinel-4 will address the geostationary observations and Sentinel-5 the low Earth orbit ones. The two missions are planned to be launched on-board Eumetsat's Meteosat Third Generation (MTG) and Post-EPS satellites, respectively. This paper presents an overview of the GMES Sentinel- 4 mission, which has been assessed at Phase-0 level. It describes the key requirements and outlines the main aspects of the candidate implementation concepts available at completion of Phase-0. The paper will particularly focus on the observation mode, the estimated performance and the related technology developments.

  16. Sentinel-3a: commissioning phase results of its optical payload

    NASA Astrophysics Data System (ADS)

    Nieke, J.; Mavrocordatos, C.

    2017-09-01

    The Sentinel-3 (S3) is a Global Land and Ocean Mission [1] currently in development as part of the European Commission's Copernicus programme (former: Global Monitoring for Environment and Security (GMES) [2]). The multi-instrument Sentinel-3 mission measures sea-surface topography, sea- and land-surface temperature, ocean colour and land colour to support ocean forecasting systems, as well as environmental and climate monitoring with near-real time data.

  17. Efficacy of Sentinel Lymph Node Biopsy in Detecting Axillary Metastasis in Breast Cancer Using Methylene Blue.

    PubMed

    Nandu, Vipul V; Chaudhari, Milind S

    2017-06-01

    Breast cancer is the leading malignancy and the second leading cause of cancer-related deaths. Axillary lymph node status is a very important prognostic factor in breast cancer patients; nodal evaluation is therefore a critical part of breast cancer management. Axillary lymph node dissection results in significant morbidity. Sentinel lymph node biopsy (SLNB) is being used in many centers to stage the axilla in planning axillary dissection management of patients and hence plays an important part in reducing morbidity among patients with carcinoma breast. The objectives of this paper is to study the (1) efficacy of sentinel lymph node biopsy in detecting axillary metastasis, (2) location of sentinel lymph node in the axilla, (3) rate of involvement of sentinel lymph nodes, and (4) incidence of skip metastasis. Thirty-five patients with breast cancer with clinically node-negative axilla were selected for the study. Methylene blue dye was injected intralesional and perilesional 20 min prior to surgery. All patients underwent modified radical mastectomy with sentinel lymph node biopsy and axillary dissection and after pathological examination diagnostic statics, namely sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were computed. Sentinel lymph node was identified in all of these patients. Sixty percent patients had pathologically positive lymph nodes in the axilla. 90.48% patients of these had sentinel lymph nodes positive for malignant cells. Incidence of skip metastasis is 9.52%. 88.57% patients had sentinel lymph node mapped to level I lymph nodes. Sensitivity of SLNB is 90.48%, specificity is 85.71%, PPV of is 90.48%, NPV is 85.71%, and accuracy is 88.57%. Sentinel lymph node biopsy is an effective method of staging the axilla and deciding on axillary clearance in patients of carcinoma breast. Unnecessary axillary dissection and associated complications can be prevented in most of patients due to sentinel

  18. Sentinel lymph node biopsy in periocular merkel cell carcinoma: a case report.

    PubMed

    Filitis, Dan C; Paragh, Gyorgy; Samie, Faramarz H; Zeitouni, Nathalie C

    2017-09-20

    The National Comprehensive Cancer Network guidelines for Merkel cell carcinoma recommend performance of the sentinel lymph node biopsy in all patients with clinically negative nodal disease for staging and treatment. Nevertheless, sentinel lymph node biopsy in the periocular region is debated as tumors are typically smaller and lymphatic variability can make performance procedurally problematic. We present a case of a Caucasian patient in their seventies who presented with a 1.0 cm periocular Merkel cell carcinoma, who underwent Mohs surgery with a Tenzel flap repair, that was found to have a positive sentinel lymph node biopsy, but who, despite parotidectomy, selective neck dissection, and radiation, succumbed to the disease. Evidence in both the site-specific and non-specific literature demonstrates: (1) Worsening prognosis with extent of lymph node burden, (2) improvements in our abilities to perform lymphoscintigraphy, (3) locoregional and distant metastatic disease in patients with tumor sizes ≤1 cm, and (4) significant rates of sentinel lymph node positivity in patients with tumor sizes ≤1 cm. Our case supports that sentinel lymph node biopsy should be considered in all clinically nodal negative periocular Merkel cell carcinoma, regardless of size, and despite limited site-specific studies on the subject.

  19. Multifunctional Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping

    DTIC Science & Technology

    2012-03-01

    undesired PMA attached to microbubble surface. Figure 1: One-pot polymer -lipid microbubbles. (a) Synthesis of thiolated poly(acrylic acid) with...Award Number: W81XWH-11-1-0215 TITLE: Multifunctional Polymer Microbubbles for Advanced Sentinel...February 2012 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Multifunctional Polymer Microbubbles for Advanced Sentinel Lymph Node Imaging and Mapping 5b

  20. Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.

    PubMed

    Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As

    2014-12-01

    To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  1. Review of the role of sentinel node biopsy in cutaneous head and neck melanoma.

    PubMed

    Roy, Jennifer M; Whitfield, Robert J; Gill, P Grantley

    2016-05-01

    Sentinel node biopsy (SNB) is recommended for selected melanoma patients in many parts of the world. This review examines the evidence surrounding the accuracy and prognostic value of SNB and completion neck dissection in head and neck melanoma. Sentinel nodes were identified in an average of 94.7% of head and neck cases compared with 95.3-100% in all melanoma cases. More false-negative sentinel nodes were found in head and neck cases. A positive sentinel node was associated with both lower disease-free survival (53.4 versus 83.2%) and overall survival (40 versus 84%). We conclude that SNB should be offered to all patients with intermediate and high-risk melanomas in the head and neck area. To date, evidence does not exist to demonstrate the safety of avoiding completion lymph node dissection in sentinel node-positive patients with head and neck melanoma. © 2015 Royal Australasian College of Surgeons.

  2. Subsurface drainage volume reduction with drainage water management: Case studies in Ohio, USA

    USDA-ARS?s Scientific Manuscript database

    One of the main contributors to poor water quality in the Mississippi River and aeral increase in the hypoxic zone in the Gulf of Mexico is intensive drainage of the cropland within the watershed. Controlled drainage has been demonstrated as an approach to curb totla drainage outflow and nutrient di...

  3. Filariasis in Travelers Presenting to the GeoSentinel Surveillance Network

    PubMed Central

    Lipner, Ettie M.; Law, Melissa A.; Barnett, Elizabeth; Keystone, Jay S.; von Sonnenburg, Frank; Loutan, Louis; Prevots, D. Rebecca; Klion, Amy D.; Nutman, Thomas B.

    2007-01-01

    Background As international travel increases, there is rising exposure to many pathogens not traditionally encountered in the resource-rich countries of the world. Filarial infections, a great problem throughout the tropics and subtropics, are relatively rare among travelers even to filaria-endemic regions of the world. The GeoSentinel Surveillance Network, a global network of medicine/travel clinics, was established in 1995 to detect morbidity trends among travelers. Principal Findings We examined data from the GeoSentinel database to determine demographic and travel characteristics associated with filaria acquisition and to understand the differences in clinical presentation between nonendemic visitors and those born in filaria-endemic regions of the world. Filarial infections comprised 0.62% (n = 271) of all medical conditions reported to the GeoSentinel Network from travelers; 37% of patients were diagnosed with Onchocerca volvulus, 25% were infected with Loa loa, and another 25% were diagnosed with Wuchereria bancrofti. Most infections were reported from immigrants and from those immigrants returning to their county of origin (those visiting friends and relatives); the majority of filarial infections were acquired in sub-Saharan Africa. Among the patients who were natives of filaria-nonendemic regions, 70.6% acquired their filarial infection with exposure greater than 1 month. Moreover, nonendemic visitors to filaria-endemic regions were more likely to present to GeoSentinel sites with clinically symptomatic conditions compared with those who had lifelong exposure. Significance Codifying the filarial infections presenting to the GeoSentinel Surveillance Network has provided insights into the clinical differences seen among filaria-infected expatriates and those from endemic regions and demonstrated that O. volvulus infection can be acquired with short-term travel. PMID:18160987

  4. Relationship between intraprostatic tracer deposits and sentinel lymph node mapping in prostate cancer patients.

    PubMed

    Buckle, Tessa; Brouwer, Oscar R; Valdés Olmos, Renato A; van der Poel, Henk G; van Leeuwen, Fijs W B

    2012-07-01

    Intraprostatic injection of the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid enables both preoperative sentinel node (SN) identification and intraoperative visualization of the SN. Relating the fluorescence deposits in embedded prostate tissue specimens to the preoperatively detected SNs also provides the opportunity to study the influence of their placement on lymphatic drainage pattern. Nineteen patients with prostate carcinoma scheduled for robot-assisted laparoscopic prostatectomy and lymph node (LN) dissection were included. ICG-(99m)Tc-nanocolloid was injected intraprostatically, guided by ultrasound. SN biopsy was performed using a combination of radioguidance and fluorescence guidance. Tracer distribution was visualized in paraffin-embedded prostate samples using ex vivo fluorescence imaging. This distribution was correlated to the number and location of the SNs identified on preoperative lymphoscintigraphy and SPECT/CT. ICG-(99m)Tc-nanocolloid helped guide surgical excision of the SNs. Ex vivo fluorescence imaging revealed a large variation in the locations of intraprostatic tracer deposits among patients. Tracer deposits in the peripheral zone correlated with a higher number of visualized LNs than deposits in the central zone (on average, 4.7 vs. 2.4 LNs per patient). Furthermore, tracer deposits in the mid gland correlated with a higher number of visualized LNs than deposits near the base or apex of the prostate (on average, 6 vs. 3.5 LNs per patient). The hybrid nature of the tracer not only enables surgical guidance but also provides an opportunity to study the correlation between the location of tracer deposits within the prostate and the number and location of preoperatively visualized SNs. These data suggest that the location at which a tracer deposit is placed influences the lymphatic drainage pattern.

  5. HiSentinel: A Stratospheric Airship

    NASA Astrophysics Data System (ADS)

    Smith, I.; Lew, T.; Perry, W.; Smith, M.

    On December 4 2005 a team led by Southwest Research Institute SwRI successfully demonstrated powered flight of the HiSentinel stratospheric airship at an altitude of 74 000 feet The development team of Aerostar International the Air Force Research Laboratory AFRL and SwRI launched the airship from Roswell N M for a five-hour technology demonstration flight The 146-foot-long airship carried a 60-pound equipment pod and propulsion system when it became only the second airship in history to achieve powered flight in the stratosphere Designed for launch from remote sites these airships do not require large hangars or special facilities Unlike most stratospheric airship concepts HiSentinel is launched flaccid with the hull only partially inflated with helium As the airship rises the helium expands until it completely inflates the hull to the rigid aerodynamic shape required for operation A description of previous Team development results of the test flight plans for future development and applicability to future science missions will be presented

  6. Soil moisture retrival from Sentinel-1 and Modis synergy

    NASA Astrophysics Data System (ADS)

    Gao, Qi; Zribi, Mehrez; Escorihuela, Maria Jose; Baghdadi, Nicolas

    2017-04-01

    This study presents two methodologies retrieving soil moisture from SAR remote sensing data. The study is based on Sentinel-1 data in the VV polarization, over a site in Urgell, Catalunya (Spain). In the two methodologies using change detection techniques, preprocessed radar data are combined with normalized difference vegetation index (NDVI) auxiliary data to estimate the mean soil moisture with a resolution of 1km. By modeling the relationship between the backscatter difference and NDVI, the soil moisture at a specific NDVI value is retrieved. The first algorithm is already developed on West Africa(Zribi et al., 2014) from ERS scatterometer data to estimate soil water status. In this study, it is adapted to Sentinel-1 data and take into account the high repetitiveness of data in optimizing the inversion approach. Another new method is developed based on the backscatter difference between two adjacent days of Sentinel-1 data w.r.t. NDVI, with smaller vegetation change, the backscatter difference is more sensitive to soil moisture. The proposed methodologies have been validated with the ground measurement in two demonstrative fields with RMS error about 0.05 (in volumetric moisture), and the coherence between soil moisture variations and rainfall events is observed. Soil moisture maps at 1km resolution are generated for the study area. The results demonstrate the potential of Sentinel-1 data for the retrieval of soil moisture at 1km or even better resolution.

  7. Orbit determination of the Sentinel satellites - preparations for GPS L2C-tracking

    NASA Astrophysics Data System (ADS)

    Peter, Heike; Fernández, Jaime; Fernández, Carlos; Féménias, Pierre

    2017-04-01

    The Copernicus POD (Precise Orbit Determination) Service is part of the Copernicus Processing Data Ground Segment (PDGS) of the Sentinel-1, -2 and -3 missions. A GMV-led consortium is operating the Copernicus POD Service being in charge of generating precise orbital products and auxiliary data files for their use as part of the processing chains of the respective Sentinel PDGS. Since April 2014 four Sentinel satellites have been launched (1A, 2A, 3A, and 1B). Sentinel-2B is expected to be launched in March 2017. Thus the CPOD Service will be operating five satellites simultaneously in spring 2017. The satellites of the Sentinel-1, -2, and -3 missions are all equipped with dual frequency high precision GPS receivers delivering the main observables for POD. Sentinel-3 satellites are additionally equipped with a laser retro reflector for Satellite Laser Ranging and a receiver for DORIS tracking. This allows an additional external validation of the Sentinel-3 orbit accuracy. The three missions require orbital products with various latencies from 30 minutes up to 20-30 days. The accuracy requirements are also different and partly very challenging, targeting 5 cm in 3D for Sentinel-1 and 2-3 cm in radial direction for Sentinel-3. The main quality control of the CPOD orbits is done by validating them with independent orbit solutions provided by the Copernicus POD Quality Working Group. The cross-comparison of orbit solutions from different institutions is essential to monitor and to improve the orbit accuracy. The GPS receivers on the B-satellites have the capability to track L2C signal. The option is, however, not yet activated, because if enabled the old L2 signal can no longer be tracked by the receiver. The measurements of many old GPS IIA and IIR satellites would have to be discarded because of the missing second frequency. To be prepared for the future, tests and simulations are foreseen to learn about the impact of the new observable on the POD results. This paper

  8. The ground prototype processor: Level-1 production during Sentinel-2 in-orbit acceptance

    NASA Astrophysics Data System (ADS)

    Petrucci, B.; Dechoz, C.; Lachérade, S.; L'Helguen, C.; Raynaud, J.-L.; Trémas, T.; Picard, C.; Rolland, A.

    2015-10-01

    Jointly with the European Commission, the Sentinel-2 earth observation optical mission is developed by the European Space Agency (ESA). Relying on a constellation of satellites put in orbit starting mid-2015, Sentinel-2 will be devoted to the monitoring of land and coastal areas worldwide thanks to an imagery at high revisit (5 days with two satellites), high resolution (10m, 20m and 60m) with large swath (290km), and multi-spectral imagery (13 bands in visible and shortwave infra-red). In this framework, the French Space Agency (CNES: Centre National d'Etudes Spatiales) supports ESA on the activities related to Image Quality, defining the image products and prototyping the processing techniques. Scope of this paper is to present the Ground Prototype Processor (GPP) that will be in charge of Level-1 production during Sentinel-2 In Orbit Acceptance phase. GPP has been developed by a European industrial consortium composed of Advanced Computer Systems (ACS), Magellium and DLR on the basis of CNES technical specification of Sentinel-2 data processing and under the joint management of ESA-ESTEC and CNES. It will assure the generation of the products used for Calibration and Validation activities and it will provide the reference data for Sentinel-2 Payload Data Ground Segment Validation. At first, Sentinel-2 end-users products definition is recalled with the associated radiometric and geometric performances; secondly the methods implemented will be presented with an overview of the Ground Image Processing Parameters that need to be tuned during the In Orbit Acceptance phase to assure the required performance of the products. Finally, the complexity of the processing having been showed, the challenges of the production in terms of data volume and processing time will be highlighted. The first Sentinel-2 Level-1 products are shown.

  9. Sentinel lymph node mapping in minimally invasive surgery: Role of imaging with color-segmented fluorescence (CSF).

    PubMed

    Lopez Labrousse, Maite I; Frumovitz, Michael; Guadalupe Patrono, M; Ramirez, Pedro T

    2017-09-01

    Sentinel lymph node mapping, alone or in combination with pelvic lymphadenectomy, is considered a standard approach in staging of patients with cervical or endometrial cancer [1-3]. The goal of this video is to demonstrate the use of indocyanine green (ICG) and color-segmented fluorescence when performing lymphatic mapping in patients with gynecologic malignancies. Injection of ICG is performed in two cervical sites using 1mL (0.5mL superficial and deep, respectively) at the 3 and 9 o'clock position. Sentinel lymph nodes are identified intraoperatively using the Pinpoint near-infrared imaging system (Novadaq, Ontario, CA). Color-segmented fluorescence is used to image different levels of ICG uptake demonstrating higher levels of perfusion. A color key on the side of the monitor shows the colors that coordinate with different levels of ICG uptake. Color-segmented fluorescence may help surgeons identify true sentinel nodes from fatty tissue that, although absorbing fluorescent dye, does not contain true nodal tissue. It is not intended to differentiate the primary sentinel node from secondary sentinel nodes. The key ranges from low levels of ICG uptake (gray) to the highest rate of ICG uptake (red). Bilateral sentinel lymph nodes are identified along the external iliac vessels using both standard and color-segmented fluorescence. No evidence of disease was noted after ultra-staging was performed in each of the sentinel nodes. Use of ICG in sentinel lymph node mapping allows for high bilateral detection rates. Color-segmented fluorescence may increase accuracy of sentinel lymph node identification over standard fluorescent imaging. The following are the supplementary data related to this article. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Above-ground biomass prediction by Sentinel-1 multitemporal data in central Italy with integration of ALOS2 and Sentinel-2 data

    NASA Astrophysics Data System (ADS)

    Laurin, Gaia Vaglio; Balling, Johannes; Corona, Piermaria; Mattioli, Walter; Papale, Dario; Puletti, Nicola; Rizzo, Maria; Truckenbrodt, John; Urban, Marcel

    2018-01-01

    The objective of this research is to test Sentinel-1 SAR multitemporal data, supported by multispectral and SAR data at other wavelengths, for fine-scale mapping of above-ground biomass (AGB) at the provincial level in a Mediterranean forested landscape. The regression results indicate good accuracy of prediction (R2=0.7) using integrated sensors when an upper bound of 400 Mg ha-1 is used in modeling. Multitemporal SAR information was relevant, allowing the selection of optimal Sentinel-1 data, as broadleaf forests showed a different response in backscatter throughout the year. Similar accuracy in predictions was obtained when using SAR multifrequency data or joint SAR and optical data. Predictions based on SAR data were more conservative, and in line with those from an independent sample from the National Forest Inventory, than those based on joint data types. The potential of S1 data in predicting AGB can possibly be improved if models are developed per specific groups (deciduous or evergreen species) or forest types and using a larger range of ground data. Overall, this research shows the usefulness of Sentinel-1 data to map biomass at very high resolution for local study and at considerable carbon density.

  11. Sentinel Lymph Node Biopsy in Breast Cancer: A Clinical Review and Update

    PubMed Central

    Haji, Altaf; Battoo, Azhar; Qurieshi, Mariya; Mir, Wahid; Shah, Mudasir

    2017-01-01

    Sentinel lymph node biopsy has become a standard staging tool in the surgical management of breast cancer. The positive impact of sentinel lymph node biopsy on postoperative negative outcomes in breast cancer patients, without compromising the oncological outcomes, is its major advantage. It has evolved over the last few decades and has proven its utility beyond early breast cancer. Its applicability and efficacy in patients with clinically positive axilla who have had a complete clinical response after neoadjuvant chemotherapy is being aggressively evaluated at present. This article discusses how sentinel lymph node biopsy has evolved and is becoming a useful tool in new clinical scenarios of breast cancer management. PMID:28970846

  12. Sentinel Lymph Node Biopsy in Breast Cancer: A Clinical Review and Update.

    PubMed

    Zahoor, Sheikh; Haji, Altaf; Battoo, Azhar; Qurieshi, Mariya; Mir, Wahid; Shah, Mudasir

    2017-09-01

    Sentinel lymph node biopsy has become a standard staging tool in the surgical management of breast cancer. The positive impact of sentinel lymph node biopsy on postoperative negative outcomes in breast cancer patients, without compromising the oncological outcomes, is its major advantage. It has evolved over the last few decades and has proven its utility beyond early breast cancer. Its applicability and efficacy in patients with clinically positive axilla who have had a complete clinical response after neoadjuvant chemotherapy is being aggressively evaluated at present. This article discusses how sentinel lymph node biopsy has evolved and is becoming a useful tool in new clinical scenarios of breast cancer management.

  13. Current status of sentinel lymph node navigation surgery in breast and gastrointestinal tract.

    PubMed

    Tangoku, Akira; Seike, Junichi; Nakano, Kiichiro; Nagao, Taeko; Honda, Junko; Yoshida, Takahiro; Yamai, Hiromichi; Matsuoka, Hisashi; Uyama, Kou; Goto, Masakazu; Miyoshi, Takanori; Morimoto, Tadaoki

    2007-02-01

    Sentinel lymph node biopsy (SLNB) has been developed as a new diagnostic and therapeutic modality in melanoma and breast cancer surgery. The purpose of the SLNB include preventing the operative morbidity and improving the pathologic stage by focusing on fewer lymph nodes using immunocytochemic and molecular technology has almost achieved in breast cancer surgery. The prognostic meaning of immunocytochemically detected micrometastases is also evaluating in the SLN and bone marrow aspirates of women with early-stage breast cancer. SLNB using available techniques have suggested that the lymphatic drainage of the gastrointestinal tract is much more complicated than other sites, skip metastasis being rather frequent because of an aberrant lymphatic drainage outside of the basin exist. At the moment, the available data does not justify reduced extent of lymphadenectomy, but provides strong evidence for an improvement in tumor staging on the basis of SLNB. Two large scale prospective multi-center trials concerning feasibility of gamma-probe and dye detection for gastric cancer are ongoing in Japan. Recent studies have shown favorable results for identification of SLN in esophageal cancer. CT lymphography with endoscopic mucosal injection of iopamidol was applicable for SLN navigation of superficial esophageal cancer. The aim of surgical treatment is complete resection of the tumor-infiltrated organ including the regional lymph nodes. Accurate detection of SLN can achieve a selection of a more sophisticated tailor made approach. The patient can make a individualized choice from a broader spectrum of therapeutic options including endoscopic, laparoscopic or laparoscopy-assisted surgery, modified radical surgery, and typical radical surgery with lymph node dissection. Ultrastaging by detecting micrometastasis at the molecular level and the choice of an adequate treatment improve the postoperative quality of life and survival. However these issues require further

  14. Biological Status Monitoring of European Fresh Water with Sentinel-2

    NASA Astrophysics Data System (ADS)

    Serra, Romain; Mangin, Antoine; Fanton d'Andon, Odile Hembise; Lauters, Francois; Thomasset, Franck; Martin-Lauzer, Francois-Regis

    2016-08-01

    Thanks to a widening range of sensors available, the observation of continental water quality for lakes and reservoirs is gaining more and more consistency and accuracy.Consistency because back in 2012, the only free sensor with a sufficient resolution (30m) was Landsat-7 which has truncated data since 2003 and a 16-day revisit time. But today, Landsat-8 and Sentinel-2A are now operating so depending on the latitude of interest, the combined revisit time dropped to 2 to 4 days which is more appropriate for such a monitoring (especially considering the cloud cover).Accuracy because Landsat-7 has a poor contrast over water whereas Landsat-8 and Sentinel-2A have a better radiometric sensitivity (more bit) and moreover Sentinel-2 offers additional spectral bands in the visible which are helpful for Chlorophyll-A concentration assessment. To sum up, with Sentinel-2, continental water quality monitoring capabilities are making a giant leap and it is important to exploit this potential the sooner. ACRI-HE has already built a strong basis to prepare Sentinel-2 by using Landsat data.Indeed, more than 600 lakes are already constantly monitored using Landsat data and their biological statuses are available on EyeOnWater (see eyeonwater.eu). Chlorophyll-A retrieval from (fresh) water leaving reflectances is the result of research activities conducted by ACRI-HE in parallel with EDF (Electricité de France) to respond to an emerging very demanding environmental monitoring through European regulations (typically the Water Framework Directive). Two parallel and complementary algorithms have thus been derived for Chlorophyll-a retrieval.Upstream of Eyeonwater, there is a complex and complete system automatically collecting images, extracting areas of interest around lakes, applying atmospheric correction (very sensitive part as atmosphere can contribute to 90% of the signal at sensor level) and then algorithms to retrieve water transparency (Secchi disk), turbidity and Chlorophyll

  15. [Role of sentinel lymph nodes and lymphatic mapping of colorectal cancer].

    PubMed

    Ivanov, K; Kolev, N; Ignatov, V; Temelkov, T; Madzhov, R

    2005-01-01

    The accuracy of staging of colorectal cancer is dependable of number of lymph nodes, colected and investegated from the pathologist. Moreover 50% of newfounded cases with colorectal cancer are diagnosed as I or II stage of the desease. Between 15% and 20% of these patients develop regional or distant metastases around 5 years after the examination, despite of the radical surgery. This may be due to pathological "understaging" (decrease of the stage), becouse of missed micrometastases, which size often is smaller than 5 mm. High accurate and specific pathologoanatomical methods for "ultrastaging" are cost-expensive, therefore their selective application to labeled sentinel lymph nodes has a economical benefit and saves a time. Moreover it is decreasing the understaging effect, assosiated with convectional pathologoanatomical investigaton. In the future, the technical progress will develop the intensive competiton between the sentinel lymph node mapping and the improved imaging diagnostic techniques as flurodeoxyglucose (18FDG), positron emision tomography (PET), or the other molecular imaging techniques. Unfortunately, the limited spatial resolution of these techniques, do not allow to be used for tumor staging as sentinel lymph node techniques. Therefore the sentinel lymphnode mapping become the choice of the lymphnode staging technique.

  16. A prospective investigation of fluorescence imaging to detect sentinel lymph nodes at robotic-assisted endometrial cancer staging.

    PubMed

    Paley, Pamela J; Veljovich, Dan S; Press, Joshua Z; Isacson, Christina; Pizer, Ellen; Shah, Chirag

    2016-07-01

    The accuracy of sentinel lymph node mapping has been shown in endometrial cancer, but studies to date have primarily focused on cohorts at low risk for nodal involvement. In our practice, we acknowledge the lack of benefit of lymphadenectomy in the low-risk subgroup and omit lymph node removal in these patients. Thus, our aim was to evaluate the feasibility and accuracy of sentinel node mapping in women at sufficient risk for nodal metastasis warranting lymphadenectomy and in whom the potential benefit of avoiding nodal procurement could be realized. To evaluate the detection rate and accuracy of fluorescence-guided sentinel lymph node mapping in endometrial cancer patients undergoing robotic-assisted staging. One hundred twenty-three endometrial cancer patients undergoing sentinel lymph node sentinel node mapping using indocyanine green were prospectively evaluated. Two mL (1.0 mg/mL) of dye were injected into the cervical stroma divided between the 2-3 and 9-10 o'clock positions at the time of uterine manipulator placement. Before hysterectomy, the retroperitoneal spaces were developed and fluorescence imaging was used for sentinel node detection. Identified sentinel nodes were removed and submitted for touch prep intraoperatively, followed by permanent assessment with routine hematoxylin and eosin levels. Patients then underwent hysterectomy, bilateral salpingo-oophorectomy, and completion bilateral pelvic and periaortic lymphadenectomy based on intrauterine risk factors determined intraoperatively (tumor size >2 cm, >50% myometrial invasion, and grade 3 histology). Of 123 patients enrolled, at least 1 sentinel node was detected in 119 (96.7%). Ninety-nine patients (80%) had bilateral pelvic or periaortic sentinel nodes detected. A total of 85 patients met criteria warranting completion lymphadenectomy. In 14 patients (16%) periaortic lymphadenectomy was not feasible, and the mean number of pelvic nodes procured was 13 (6-22). Of the 71 patients undergoing

  17. Interspecific signalling between mutualists: food-thieving drongos use a cooperative sentinel call to manipulate foraging partners

    PubMed Central

    Baigrie, Bruce D.; Thompson, Alex M.; Flower, Tom P.

    2014-01-01

    Interspecific communication is common in nature, particularly between mutualists. However, whether signals evolved for communication with other species, or are in fact conspecific signals eavesdropped upon by partners, is often unclear. Fork-tailed drongos (Dicrurus adsimilis) associate with mixed-species groups and often produce true alarms at predators, whereupon associating species flee to cover, but also false alarms to steal associating species' food (kleptoparasitism). Despite such deception, associating species respond to drongo non-alarm calls by increasing their foraging and decreasing vigilance. Yet, whether these calls represent interspecific sentinel signals remains unknown. We show that drongos produced a specific sentinel call when foraging with a common associate, the sociable weaver (Philetairus socius), but not when alone. Weavers increased their foraging and decreased vigilance when naturally associating with drongos, and in response to sentinel call playback. Further, drongos sentinel-called more often when weavers were moving, and weavers approached sentinel calls, suggesting a recruitment function. Finally, drongos sentinel-called when weavers fled following false alarms, thereby reducing disruption to weaver foraging time. Results therefore provide evidence of an ‘all clear’ signal that mitigates the cost of inaccurate communication. Our results suggest that drongos enhance exploitation of a foraging mutualist through coevolution of interspecific sentinel signals. PMID:25080343

  18. Estimating meningitis hospitalization rates for sentinel hospitals conducting invasive bacterial vaccine-preventable diseases surveillance.

    PubMed

    2013-10-04

    The World Health Organization (WHO)-coordinated Global Invasive Bacterial Vaccine-Preventable Diseases (IB-VPD) sentinel hospital surveillance network provides data for decision making regarding use of pneumococcal conjugate vaccine and Haemophilus influenzae type b (Hib) vaccine, both recommended for inclusion in routine childhood immunization programs worldwide. WHO recommends that countries conduct sentinel hospital surveillance for meningitis among children aged <5 years, including collection of cerebrospinal fluid (CSF) for laboratory detection of bacterial etiologies. Surveillance for pneumonia and sepsis are recommended at selected hospitals with well-functioning laboratories where meningitis surveillance consistently meets process indicators (e.g., surveillance performance indicators). To use sentinel hospital surveillance for meningitis to estimate meningitis hospitalization rates, WHO developed a rapid method to estimate the number of children at-risk for meningitis in a sentinel hospital catchment area. Monitoring changes in denominators over time using consistent methods is essential for interpreting changes in sentinel surveillance incidence data and for assessing the effect of vaccine introduction on disease epidemiology. This report describes the method and its use in The Gambia and Senegal.

  19. Ice/water Classification of Sentinel-1 Images

    NASA Astrophysics Data System (ADS)

    Korosov, Anton; Zakhvatkina, Natalia; Muckenhuber, Stefan

    2015-04-01

    Sea Ice monitoring and classification relies heavily on synthetic aperture radar (SAR) imagery. These sensors record data either only at horizontal polarization (RADARSAT-1) or vertically polarized (ERS-1 and ERS-2) or at dual polarization (Radarsat-2, Sentinel-1). Many algorithms have been developed to discriminate sea ice types and open water using single polarization images. Ice type classification, however, is still ambiguous in some cases. Sea ice classification in single polarization SAR images has been attempted using various methods since the beginning of the ERS programme. The robust classification using only SAR images that can provide useful results under varying sea ice types and open water tend to be not generally applicable in operational regime. The new generation SAR satellites have capability to deliver images in several polarizations. This gives improved possibility to develop sea ice classification algorithms. In this study we use data from Sentinel-1 at dual-polarization, i.e. HH (horizontally transmitted and horizontally received) and HV (horizontally transmitted, vertically received). This mode assembles wide SAR image from several narrower SAR beams, resulting to an image of 500 x 500 km with 50 m resolution. A non-linear scheme for classification of Sentinel-1 data has been developed. The processing allows to identify three classes: ice, calm water and rough water at 1 km spatial resolution. The raw sigma0 data in HH and HV polarization are first corrected for thermal and random noise by extracting the background thermal noise level and smoothing the image with several filters. At the next step texture characteristics are computed in a moving window using a Gray Level Co-occurence Matrix (GLCM). A neural network is applied at the last step for processing array of the most informative texture characteristics and ice/water classification. The main results are: * the most informative texture characteristics to be used for sea ice classification

  20. Combined Landsat-8 and Sentinel-2 Burned Area Mapping

    NASA Astrophysics Data System (ADS)

    Huang, H.; Roy, D. P.; Zhang, H.; Boschetti, L.; Yan, L.; Li, Z.

    2017-12-01

    Fire products derived from coarse spatial resolution satellite data have become an important source of information for the multiple user communities involved in fire science and applications. The advent of the MODIS on NASA's Terra and Aqua satellites enabled systematic production of 500m global burned area maps. There is, however, an unequivocal demand for systematically generated higher spatial resolution burned area products, in particular to examine the role of small-fires for various applications. Moderate spatial resolution contemporaneous satellite data from Landsat-8 and the Sentinel-2A and -2B sensors provide the opportunity for detailed spatial mapping of burned areas. Combined, these polar-orbiting systems provide 10m to 30m multi-spectral global coverage more than once every three days. This NASA funded research presents results to prototype a combined Landsat-8 Sentinel-2 burned area product. The Landsat-8 and Sentinel-2 pre-processing, the time-series burned area mapping algorithm, and preliminary results and validation using high spatial resolution commercial satellite data over Africa are presented.

  1. Sentinel lymph node biopsy in clinically detected ductal carcinoma in situ.

    PubMed

    Al-Ameer, Ahmed Yahia; Al Nefaie, Sahar; Al Johani, Badria; Anwar, Ihab; Al Tweigeri, Taher; Tulbah, Asma; Alshabanah, Mohmmed; Al Malik, Osama

    2016-04-10

    To study the indications for sentinel lymph node biopsy (SLNB) in clinically-detected ductal carcinoma in situ (CD-DCIS). A retrospective analysis of 20 patients with an initial diagnosis of pure DCIS by an image-guided core needle biopsy (CNB) between June 2006 and June 2012 was conducted at King Faisal Specialist Hospital. The accuracy of performing SLNB in CD-DCIS, the rate of sentinel and non-sentinel nodal metastasis, and the histologic underestimation rate of invasive cancer at initial diagnosis were analyzed. The inclusion criteria were a preoperative diagnosis of pure DCIS with no evidence of invasion. We excluded any patient with evidence of microinvasion or invasion. There were two cases of mammographically detected DCIS and 18 cases of CD-DCIS. All our patients were diagnosed by an image-guided CNB except two patients who were diagnosed by fine needle aspiration (FNA). All patients underwent breast surgery, SLNB, and axillary lymph node dissection (ALND) if the SLN was positive. Twenty patients with an initial diagnosis of pure DCIS underwent SLNB, 2 of whom had an ALND. The mean age of the patients was 49.7 years (range, 35-70). Twelve patients (60%) were premenopausal and 8 (40%) were postmenopausal. CNB was the diagnostic procedure for 18 patients, and 2 who were diagnosed by FNA were excluded from the calculation of the underestimation rate. Two out of 20 had a positive SLNB and underwent an ALND and neither had additional non sentinel lymph node metastasis. Both the sentinel visualization rate and the intraoperative sentinel identification rate were 100%. The false negative rate was 0%. Only 2 patients had a positive SLNB (10%) and neither had additional metastasis following an ALND. After definitive surgery, 3 patients were upstaged to invasive ductal carcinoma (3/18 = 16.6%) and 3 other patients were upstaged to DCIS with microinvasion (3/18 = 16.6%). Therefore the histologic underestimation rate of invasive disease was 33%. SLNB in CD-DCIS is

  2. FoxP3 and indoleamine 2,3-dioxygenase immunoreactivity in sentinel nodes from melanoma patients.

    PubMed

    Ryan, Marisa; Crow, Jennifer; Kahmke, Russel; Fisher, Samuel R; Su, Zuowei; Lee, Walter T

    2014-01-01

    1) Assess FoxP3/indoleamine 2,3-dioxygenase immunoreactivity in head and neck melanoma sentinel lymph nodes and 2) correlate FoxP3/indoleamine 2,3-dioxygenase with sentinel lymph node metastasis and clinical recurrence. Retrospective cohort study. Patients with sentinel lymph node biopsy for head and neck melanoma between 2004 and 2011 were identified. FoxP3/indoleamine 2,3-dioxygenase prevalence and intensity were determined from the nodes. Poor outcome was defined as local, regional or distant recurrence. The overall immunoreactivity score was correlated with clinical recurrence and sentinel lymph node metastasis using the chi-square test for trend. Fifty-six sentinel lymph nodes were reviewed, with 47 negative and 9 positive for melanoma. Patients with poor outcomes had a statistically significant trend for higher immunoreactivity scores (p=0.03). Positive nodes compared to negative nodes also had a statistically significant trend for higher immunoreactivity scores (p=0.03). Among the negative nodes, there was a statistically significant trend for a poor outcome with higher immunoreactivity scores (p=0.02). FoxP3/indoleamine 2,3-dioxygenase immunoreactivity correlates with sentinel lymph node positivity and poor outcome. Even in negative nodes, higher immunoreactivity correlated with poor outcome. Therefore higher immunoreactivity may portend a worse prognosis even without metastasis in the sentinel lymph node. This could identify a subset of patients that may benefit from future trials and treatment for melanoma through Treg and IDO suppression. Published by Elsevier Inc.

  3. In-office drainage of sinus Mucoceles: An alternative to operating-room drainage.

    PubMed

    Barrow, Emily M; DelGaudio, John M

    2015-05-01

    Endoscopic drainage has become the standard of care for the treatment of mucoceles. In many patients this can be performed in the office. This study reviews our experience with in-office endoscopic mucocele drainage. Retrospective chart review. A retrospective review of one surgeon's experience with in-office endoscopic drainage of sinus mucoceles between 2006 and 2014 was performed. Charts were reviewed for patient demographics, previous surgery, mucocele location, bone erosion, and outcomes. Thirty-two patients underwent 36 in-office drainage procedures. All procedures were performed under topical/local anesthesia. The mean age was 55 years (range, 17-92 years). The mean follow-up time was 444 days. Fifty-five percent had previous sinus surgery. The primary sinus involved was the frontal (12), anterior (11), posterior ethmoid (six), maxillary (four), and sphenoid (two). Bone erosion was noted to be present on computed tomography in 18 mucoceles (51%) (16 orbital, seven skull-base). All mucoceles were successfully accessed in the office with the exception of one, which was aborted due to neo-osteogenesis. Five patients (14% of mucoceles) required additional surgery, two for mucocele recurrence and three for septated mucoceles not completely drained in the office. No treatment complications occurred. All but one patient preferred in-office to operating-room drainage. In-office drainage of sinus mucoceles is well tolerated by patients, with high success and low complication rates, even in large mucoceles with bone erosion. The presence of septations and neo-osteogenesis reduce the likelihood of complete drainage and are relative contraindications. Orbital and skull base erosion are not contraindications. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    PubMed

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  5. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    PubMed

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  6. Drainage water management

    USDA-ARS?s Scientific Manuscript database

    This article introduces a series of papers that report results of field studies to determine the effectiveness of drainage water management (DWM) on conserving drainage water and reducing losses of nitrogen (N) to surface waters. The series is focused on the performance of the DWM (also called contr...

  7. Evaluating Sentinel-2 for Lakeshore Habitat Mapping Based on Airborne Hyperspectral Data.

    PubMed

    Stratoulias, Dimitris; Balzter, Heiko; Sykioti, Olga; Zlinszky, András; Tóth, Viktor R

    2015-09-11

    Monitoring of lakeshore ecosystems requires fine-scale information to account for the high biodiversity typically encountered in the land-water ecotone. Sentinel-2 is a satellite with high spatial and spectral resolution and improved revisiting frequency and is expected to have significant potential for habitat mapping and classification of complex lakeshore ecosystems. In this context, investigations of the capabilities of Sentinel-2 in regard to the spatial and spectral dimensions are needed to assess its potential and the quality of the expected output. This study presents the first simulation of the high spatial resolution (i.e., 10 m and 20 m) bands of Sentinel-2 for lakeshore mapping, based on the satellite's Spectral Response Function and hyperspectral airborne data collected over Lake Balaton, Hungary in August 2010. A comparison of supervised classifications of the simulated products is presented and the information loss from spectral aggregation and spatial upscaling in the context of lakeshore vegetation classification is discussed. We conclude that Sentinel-2 imagery has a strong potential for monitoring fine-scale habitats, such as reed beds.

  8. Evaluating Sentinel-2 for Lakeshore Habitat Mapping Based on Airborne Hyperspectral Data

    PubMed Central

    Stratoulias, Dimitris; Balzter, Heiko; Sykioti, Olga; Zlinszky, András; Tóth, Viktor R.

    2015-01-01

    Monitoring of lakeshore ecosystems requires fine-scale information to account for the high biodiversity typically encountered in the land-water ecotone. Sentinel-2 is a satellite with high spatial and spectral resolution and improved revisiting frequency and is expected to have significant potential for habitat mapping and classification of complex lakeshore ecosystems. In this context, investigations of the capabilities of Sentinel-2 in regard to the spatial and spectral dimensions are needed to assess its potential and the quality of the expected output. This study presents the first simulation of the high spatial resolution (i.e., 10 m and 20 m) bands of Sentinel-2 for lakeshore mapping, based on the satellite’s Spectral Response Function and hyperspectral airborne data collected over Lake Balaton, Hungary in August 2010. A comparison of supervised classifications of the simulated products is presented and the information loss from spectral aggregation and spatial upscaling in the context of lakeshore vegetation classification is discussed. We conclude that Sentinel-2 imagery has a strong potential for monitoring fine-scale habitats, such as reed beds. PMID:26378538

  9. Slope Stability Analysis and Event Reconstruction of the Karrat Fjord (W Greenland) Rock Avalanche from June 2017 using Sentinel-1 and Sentinel-2 data

    NASA Astrophysics Data System (ADS)

    Langley, K.; Caduff, R.; Wiesmann, A.; Mätzler, E.

    2017-12-01

    A massive rock slope failure that led to a rock avalanche in the Karrat Fjord, Western Greenland, caused a tsunami on 17 June 2017. The tsunami reached local villages and resulted in loss of life and damage to infrastructure. The length of the rock avalanche detachment zone is on the order of 800 m. It is located at an elevation of 1'000 m above the fjord with a slant distance of 2'000 m to the shore line. Since very little information was available on the state of the originating mountain slope, satellite based information was gathered immediately after the event in order to assess the processes on the slope. Thanks to the quick data distribution through Copernicus, we could process the entire available datasets of the Synthetic Aperture Radar (SAR) sensors Sentinel-1A/B and the optical sensor Sentinel-2. The pre-, syn, and post-event history could be reconstructed using ascending orbit Sentinel-1 data, available from October 2014 in 12 and from early 2017 on in 6d interval. We looked at the differential interferograms to detect coherent surface displacements in line-of-sight (LOS). Coherent interferograms after the snow-melt in May 2017 revealed surface displacements of 10-15 cm/year with accelerating trend in the later detachment zone. The known limitation for interferometry in wet-snow condition hinders the determination of areas undergoing surface deformation. However, a detailed coherence analysis showed that during the previous winter, a large avalanche type process must have happened in the later detachment zone. A radar backscatter analysis showed, that significant changes in the corridor of 500 m of the area affected by the rock avalanche can be dated between 5 and 11 November 2016. The traces of the event could be verified with optical imagery from Sentinel-2 dating from 23 May 2017. An overall analysis on the mountain side revealed the presence of a number of active zones. An inventory of the outlines of the moving areas containing information on the

  10. Sentinel-1 - the radar mission for GMES operational land and sea services

    NASA Astrophysics Data System (ADS)

    Attema, Evert; Bargellini, Pierre; Edwards, Peter; Levrini, Guido; Lokas, Svein; Moeller, Ludwig; Rosich-Tell, Betlem; Secchi, Patrizia; Torres, Ramon; Davidson, Malcolm; Snoeij, Paul

    2007-08-01

    The ESA Sentinels will be the first series of operational satellites to meet the Earth observation needs of the European Union - ESA Global Monitoring for Environment and Security (GMES) programme. Existing and planned space assets will be complemented by new developments from ESA. The first is Sentinel-1, a pair of synthetic aperture radar (SAR) imaging satellites.

  11. ORAM-SENTINEL{trademark} demonstration at Fitzpatrick. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, L.K.; Anderson, V.M.; Mohammadi, K.

    1998-06-01

    New York Power Authority, in cooperation with EPRI, installed the ORAM-SENTINEL{trademark} software at James A. Fitzpatrick (JAF) Nuclear Power Plant. This software incorporates models of safety systems and support systems that are used for defense-in-depth in the plant during outage and on-line periods. A secondary goal was to include some pre-analyzed risk results to validate the methodology for quantitative assessment of the plant risks during proposed on-line maintenance. During the past year, New York Power Authority personnel have become familiar with the formal computerized Safety Assessment process associated with on-line and outage maintenance. The report describes techniques and lessons learnedmore » during development of the ORAM-SENTINEL model at JAF. It overviews the systems important to the Safety Function Assessment Process and provides details on development of the Plant Transient Assessment process using the station emergency operating procedures. The assessment results are displayed by color (green, yellow, orange, red) to show decreasing safety conditions. The report describes use of the JAF Probabilistic Safety Assessment within the ORAM-SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator.« less

  12. Verification of the Sentinel-4 focal plane subsystem

    NASA Astrophysics Data System (ADS)

    Williges, Christian; Uhlig, Mathias; Hilbert, Stefan; Rossmann, Hannes; Buchwinkler, Kevin; Babben, Steffen; Sebastian, Ilse; Hohn, Rüdiger; Reulke, Ralf

    2017-09-01

    The Sentinel-4 payload is a multi-spectral camera system, designed to monitor atmospheric conditions over Europe from a geostationary orbit. The German Aerospace Center, DLR Berlin, conducted the verification campaign of the Focal Plane Subsystem (FPS) during the second half of 2016. The FPS consists, of two Focal Plane Assemblies (FPAs), two Front End Electronics (FEEs), one Front End Support Electronic (FSE) and one Instrument Control Unit (ICU). The FPAs are designed for two spectral ranges: UV-VIS (305 nm - 500 nm) and NIR (750 nm - 775 nm). In this publication, we will present in detail the set-up of the verification campaign of the Sentinel-4 Qualification Model (QM). This set up will also be used for the upcoming Flight Model (FM) verification, planned for early 2018. The FPAs have to be operated at 215 K +/- 5 K, making it necessary to exploit a thermal vacuum chamber (TVC) for the test accomplishment. The test campaign consists mainly of radiometric tests. This publication focuses on the challenge to remotely illuminate both Sentinel-4 detectors as well as a reference detector homogeneously over a distance of approximately 1 m from outside the TVC. Selected test analyses and results will be presented.

  13. Discrete call types referring to predation risk enhance the efficiency of the meerkat sentinel system

    PubMed Central

    Rauber, R.; Manser, M. B.

    2017-01-01

    Sentinel behaviour, a form of coordinated vigilance, occurs in a limited range of species, mostly in cooperative breeders. In some species sentinels confirm their presence vocally by giving a single sentinel call type, whereby the rate and subtle acoustic changes provide graded information on the variation of perceived predation risk. In contrast, meerkat (Suricata suricatta) sentinels produce six different sentinel call types. Here we show that manipulation of perception of danger has different effects on the likelihood of emitting these different call types, and that these call types affect foraging individuals differently. Increasing the perceived predation risk by playing back alarm calls decreased the production rate of the common short note calls and increased the production rate of the rare long calls. Playbacks of short note calls increased foraging behaviour and decreased vigilance in the rest of the group, whereas the opposite was observed when playing long calls. This suggests that the common call types act as all-clear signals, while the rare call types have a warning function. Therefore, meerkats increase the efficiency of their sentinel system by producing several discrete call types that represent changes in predation risk and lead to adjustments of the group’s vigilance behaviour. PMID:28303964

  14. 76 FR 22038 - Revision to the South Coast Portion of the California State Implementation Plan, CPV Sentinel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-20

    ... California SIP. This source-specific SIP revision is known as the CPV Sentinel Energy Project AB 1318... list of those emissions credits. The Sentinel Energy Project is a source that is not authorized to... District to transfer certain emissions credits to one stationary source, the Sentinel Energy Project. The...

  15. Isthmocervical labelling and SPECT/CT for optimized sentinel detection in endometrial cancer: technique, experience and results.

    PubMed

    Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H

    2014-08-01

    We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), p<0.01). If SLN were identified in one hemi-pelvis, the histological evaluation of the SLN correctly predicted lymph node (LN) metastases for this basin which led to sensitivity 100%, negative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Drainage area data for Alabama streams

    USGS Publications Warehouse

    Stallings, J.S.; Peirce, L.B.

    1957-01-01

    The drainage area of a river basin is an important parameter in many engineering equations used for hydrologic design. It is not a parameter, however, that always requires precise measurement. Factors in the hydrologic cycle such as rainfall, runoff, transpiration, and infiltration cannot be measured nearly as closely as drainage area. Largely for this reason, drainage areas are often measured to varying degrees of precision depending upon the immediate need, with little thought to some other use or some other user of the figure obtained. It can readily be appreciated that this practice, continued for long by many different agencies, will result in a heterogeneous collection of drainage area figures, often discordant and of an accuracy unknown to any but those who computed them. Figures of drainage area published by various Federal agencies are frequently discrepant or contradictory, giving rise to confusion in the use of drainage area data. Seeking to better this situation, the Federal Inter-Agency River Basin Committee (FIARBC) in November 1951 published its Bulletin No. 4, Inter-Agency Coordination of Drainage Area Data. That Bulletin recommended procedures to be followed by the interested Federal agencies “for coordinating drainage area data in the interest of promoting uniformity, reducing confusion and contradiction of published figures, and improving the ready availability of drainage area data pertaining to drainage basins of the United States and its possessions.”

  17. On Clear-Cut Mapping with Time-Series of Sentinel-1 Data in Boreal Forest

    NASA Astrophysics Data System (ADS)

    Rauste, Yrjo; Antropov, Oleg; Mutanen, Teemu; Hame, Tuomas

    2016-08-01

    Clear-cutting is the most drastic and wide-spread change that affects the hydrological and carbon-balance proper- ties of forested land in the Boreal forest zone1.A time-series of 36 Sentinel-1 images was used to study the potential for mapping clear-cut areas. The time series covered one and half year (2014-10-09 ... 2016-03-20) in a 200-km-by-200-km study site in Finland. The Sentinel- 1 images were acquired in Interferometric Wide-swath (IW), dual-polarized mode (VV+VH). All scenes were acquired in the same orbit configuration. Amplitude im- ages (GRDH product) were used. The Sentinel-1 scenes were ortho-rectified with in-house software using a digi- tal elevation model (DEM) produced by the Land Survey of Finland. The Sentinel-1 amplitude data were radio- metrically corrected for topographic effects.The temporal behaviour of C-band backscatter was stud- ied for areas representing 1) areas clear-cut during the ac- quisition of the Sentinel-1 time-series, 2) areas remaining forest during the acquisition of the Sentinel-1 time-series, and 3) areas that had been clear-cut before the acquisition of the Sentinel-1 time-series.The following observations were made:1. The separation between clear-cut areas and forest was generally low;2. Under certain acquisition conditions, clear-cut areas were well separable from forest;3. The good scenes were acquired: 1) in winter during thick snow cover, and 2) in late summer towards the end of a warm and dry period;4. The separation between clear-cut and forest was higher in VH polarized data than in VV-polarized data.5. The separation between clear-cut and forest was higher in the winter/snow scenes than in the dry summer scenes.

  18. Sentinel-3A Views Ocean Variability More Accurately at Finer Resolution

    NASA Astrophysics Data System (ADS)

    Heslop, E. E.; Sánchez-Román, A.; Pascual, A.; Rodríguez, D.; Reeve, K. A.; Faugère, Y.; Raynal, M.

    2017-12-01

    This is the first multiplatform evaluation involving data from the new Sentinel-3A altimeter. An experiment was undertaken in the Algerian Basin, employing an ocean glider and a ship mission, along the same track and synchronous with an overpass of the Sentinel-3A mission. This provided three independent views of the ocean velocity field, along a section that encompassed three different oceanographic regimes. The results demonstrate the capacity of Sentinel-3A to retrieve fine-scale oceanographic features ( 20 km). The intercomparison with in situ platforms showed a significant improvement, order 30% in resolution and 42% in velocity accuracy using a synthetic aperture radar mode with respect to lower-resolution mode of conventional altimetry. In addition, the three-platform view provided valuable insight into the variability of evolving oceanographic features, in an area of the Mediterranean that remains chronically under sampled.

  19. A study on uterine lymphatic anatomy for standardization of pelvic sentinel lymph node detection in endometrial cancer.

    PubMed

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Arechvo, Anastasija; Persson, Jan

    2017-05-01

    To describe the anatomy of uterine lymphatic drainage following cervical or fundal tracer injection to enable standardization of a pelvic sentinel lymph node (SLN) concept in endometrial cancer (EC). A prospective consecutive study of women with EC was conducted. A fluorescent dye (Indocyanine green) was injected into the cervix (n=60) or the uterine fundus (n=30). A systematic trans- and retroperitoneal mapping of uterine lymphatic drainage was performed. Positions of the pelvic SLNs, defined by afferent lymph vessels, and lymph node metastases were compared. Two consistent lymphatic pathways with pelvic SLNs were identified irrespective of injection site; an upper paracervical pathway (UPP) with draining medial external and/or obturator lymph nodes and a lower paracervical pathway (LPP) with draining internal iliac and/or presacral lymph nodes. Bilateral display of at least one pelvic pathway following cervical and fundal injection occurred in 98% and 80% respectively (p=0.005). Bilateral display of both pelvic pathways occurred in 30% and 20% respectively (p=0.6) as the LPP was less often displayed. Nearly one third of the 19% node positive patients had metastases along the LPP. No false negative SLNs were identified. Based on uterine lymphatic anatomy a bilateral detection of at least one SLN in both the UPP and LPP should be aimed for. Absence of display of the LPP may warrant a full presacral lymphadenectomy. Although pelvic pathways and positions of SLNs are independent of the tracer injection site, cervical injection is preferable due to a higher technical success rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Towards a long-term Science Exploitation Plan for the Sea and Land Surface Temperature Radiometer on Sentinel-3 and the Along-Track Scanning Radiometers

    NASA Astrophysics Data System (ADS)

    Remedios, John J.; Llewellyn-Jones, David

    2014-05-01

    The Sea and Land Surface Temperature Radiometer (SLSTR) on Sentinel-3 is the latest satellite instrument in a series of dual-angle optical and thermal sensors, the Along-Track Scanning Radiometers (ATSRs). Operating on Sentinel-3, the SLSTR has a number of significant improvements compared to the original ATSRs including wider swaths for nadir and dual angles, emphasis on all surface temperature domains, dedicated fire channels and additional cloud channels. The SLSTR therefore provides some excellent opportunities to extend science undertaken with the ATSRs whilst also providing long-term data sets to investigate climate change. The European Space Agency, together with the Department of Energy and Climate Change, sponsored the production of an Exploitation Plan for the ATSRs. In the last year, this been extended to cover the SLSTR also. The plan enables UK and European member states to plan activities related to SLSTR in a long-term context. Covering climate change, oceanography, land surface, atmosphere and cryosphere science, particular attention is paid to the exploitation of long-term data sets. In the case of SLSTR, relevant products include sea, land, lake and ice surface temperatures; aerosols and clouds; fires and gas flares; land surface reflectances. In this presentation, the SLSTR and ATSR science Exploitation Plan will be outlined with emphasis on SLSTR science opportunities, on appropriate co-ordinating mechanisms and on example implementation plans. Particular attention will be paid to the challenges of linking ATSR records with SLSTR to provide consistent long-term data sets, and on the international context of such data sets. The exploitation plan approach to science may prove relevant and useful for other Sentinel instruments.

  1. Routine Sub-hepatic Drainage versus No Drainage after Laparoscopic Cholecystectomy: Open, Randomized, Clinical Trial.

    PubMed

    Shamim, Muhammad

    2013-02-01

    Surgeons are still following the old habit of routine subhepatic drainage following laparoscopic cholecystectomy (LC). This study aims to compare the outcome of subhepatic drainage with no drainage after LC. This prospective study was conducted in two phases. Phase I was open, randomized controlled trial (RCT), conducted in Civil Hospital Karachi, from August 2004 to June 2005. Phase II was descriptive case series, conducted in author's practice hospitals of Karachi, from July 2005 to December 2009. In phase I, 170 patients with chronic calculous cholecystitis underwent LC. Patients were divided into two groups, subhepatic drainage (group A: 79 patients) or no drainage (group B: 76 patients). The rest 15 patients were excluded either due to conversion or elective subhepatic drainage. In phase II, 218 consecutive patients were enrolled, who underwent LC with no subhepatic drainage. Duration of operation, character, and amount of drain fluid (if placed), postoperative ultrasound for subhepatic collection, postoperative chest X-ray for the measurement of subdiaphragmatic air, postoperative pain, postoperative nausea/vomiting, duration of hospital stay, and preoperative or postoperative complications were noted and analyzed. Duration of operation and hospital stay was slightly longer in group A patients (P values 0.002 and 0.029, respectively); postoperative pain perception, nausea/vomiting, and postoperative complications were nearly same in both groups (P value 0.064, 0.078, and 0.003, respectively). Subhepatic fluid collection was more in group A (P = 0.002), whereas subdiaphragmatic air collection was more in group B (P = 0.003). Phase II results were nearly similar to group B patients in phase I. Routine subhepatic drainage after LC is not necessary in uncomplicated cases.

  2. Sequential sentinel SNP Regional Association Plots (SSS-RAP): an approach for testing independence of SNP association signals using meta-analysis data.

    PubMed

    Zheng, Jie; Gaunt, Tom R; Day, Ian N M

    2013-01-01

    Genome-Wide Association Studies (GWAS) frequently incorporate meta-analysis within their framework. However, conditional analysis of individual-level data, which is an established approach for fine mapping of causal sites, is often precluded where only group-level summary data are available for analysis. Here, we present a numerical and graphical approach, "sequential sentinel SNP regional association plot" (SSS-RAP), which estimates regression coefficients (beta) with their standard errors using the meta-analysis summary results directly. Under an additive model, typical for genes with small effect, the effect for a sentinel SNP can be transformed to the predicted effect for a possibly dependent SNP through a 2×2 2-SNP haplotypes table. The approach assumes Hardy-Weinberg equilibrium for test SNPs. SSS-RAP is available as a Web-tool (http://apps.biocompute.org.uk/sssrap/sssrap.cgi). To develop and illustrate SSS-RAP we analyzed lipid and ECG traits data from the British Women's Heart and Health Study (BWHHS), evaluated a meta-analysis for ECG trait and presented several simulations. We compared results with existing approaches such as model selection methods and conditional analysis. Generally findings were consistent. SSS-RAP represents a tool for testing independence of SNP association signals using meta-analysis data, and is also a convenient approach based on biological principles for fine mapping in group level summary data. © 2012 Blackwell Publishing Ltd/University College London.

  3. Estimating Velocities of Glaciers Using Sentinel-1 SAR Imagery

    NASA Astrophysics Data System (ADS)

    Gens, R.; Arnoult, K., Jr.; Friedl, P.; Vijay, S.; Braun, M.; Meyer, F. J.; Gracheva, V.; Hogenson, K.

    2017-12-01

    In an international collaborative effort, software has been developed to estimate the velocities of glaciers by using Sentinel-1 Synthetic Aperture Radar (SAR) imagery. The technique, initially designed by the University of Erlangen-Nuremberg (FAU), has been previously used to quantify spatial and temporal variabilities in the velocities of surging glaciers in the Pakistan Karakoram. The software estimates surface velocities by first co-registering image pairs to sub-pixel precision and then by estimating local offsets based on cross-correlation. The Alaska Satellite Facility (ASF) at the University of Alaska Fairbanks (UAF) has modified the software to make it more robust and also capable of migration into the Amazon Cloud. Additionally, ASF has implemented a prototype that offers the glacier tracking processing flow as a subscription service as part of its Hybrid Pluggable Processing Pipeline (HyP3). Since the software is co-located with ASF's cloud-based Sentinel-1 archive, processing of large data volumes is now more efficient and cost effective. Velocity maps are estimated for Single Look Complex (SLC) SAR image pairs and a digital elevation model (DEM) of the local topography. A time series of these velocity maps then allows the long-term monitoring of these glaciers. Due to the all-weather capabilities and the dense coverage of Sentinel-1 data, the results are complementary to optically generated ones. Together with the products from the Global Land Ice Velocity Extraction project (GoLIVE) derived from Landsat 8 data, glacier speeds can be monitored more comprehensively. Examples from Sentinel-1 SAR-derived results are presented along with optical results for the same glaciers.

  4. Polarimetry-Based Land Cover Classification with Sentinel-1 Data

    NASA Astrophysics Data System (ADS)

    Banque, Xavier; Lopez-Sanchez, Juan M.; Monells, Daniel; Ballester, David; Duro, Javier; Koudogbo, Fifame

    2015-04-01

    The presented research focuses on the assessment of the exploitation of the Sentinel-1 dual polarization data for land cover classification. In order to take advantage of massive data availability produced by Sentinel-1, data used in this research work is Interferometric Wide Swath mode, acquired over the Altmühlsee, Weißenburg-Gunzenhausen, Germany during November 2014. The developed preliminary classifier is based on the interpretation of several polarimetric figures as well as the Dual Polarization Entropy/Alpha Decomposition. Specifically, the following polarimetric indicators will be assessed: the channels cross- correlation, the cross and co-polar channels ratio and both cross and co-polar backscattering coefficients. The work carried out concentrates on the joint interpretation of the backscattering response of the co-pol and cross- pol channels for four or five different distributed targets that set the basis for an unsupervised simple land cover classifier. The developed research targets a preliminary unsupervised classifier able to differentiate between four or five terrain classes, including water, urban, forest and bare soil. Obtained results pave the way for the development of a Sentinel-1 based land classifier.

  5. Effect of time to sentinel-node biopsy on the prognosis of cutaneous melanoma.

    PubMed

    Tejera-Vaquerizo, Antonio; Nagore, Eduardo; Puig, Susana; Robert, Caroline; Saiag, Philippe; Martín-Cuevas, Paula; Gallego, Elena; Herrera-Acosta, Enrique; Aguilera, José; Malvehy, Josep; Carrera, Cristina; Cavalcanti, Andrea; Rull, Ramón; Vilalta-Solsona, Antonio; Lannoy, Emilie; Boutros, Celine; Benannoune, Naima; Tomasic, Gorana; Aegerte, Philippe; Vidal-Sicart, Sergi; Palou, Josep; Alos, L Lúcia; Requena, Celia; Traves, Víctor; Pla, Ángel; Bolumar, Isidro; Soriano, Virtudes; Guillén, Carlos; Herrera-Ceballos, Enrique

    2015-09-01

    In patients with primary cutaneous melanoma, there is generally a delay between excisional biopsy of the primary tumour and sentinel-node biopsy. The objective of this study is to analyse the prognostic implications of this delay. This was an observational, retrospective, cohort study in four tertiary referral hospitals. A total of 1963 patients were included. The factor of interest was the interval between the date of the excisional biopsy of the primary melanoma and the date of the sentinel-node biopsy (delay time) in the prognosis. The primary outcome was melanoma-specific survival and disease-free survival. A delay time of 40 days or less (hazard ratio (HR), 1.7; confidence interval (CI), 1.2-2.5) increased Breslow thickness (Breslow ⩾ 2 mm, HR, > 3.7; CI, 1.4-10.7), ulceration (HR, 1.6; CI, 1.1-2.3), sentinel-node metastasis (HR, 2.9; CI, 1.9-4.2), and primary melanoma localised in the head or neck were independently associated with worse melanoma-specific survival (all P < 0.03). The stratified analysis showed that the effect of delay time was at the expense of the patients with a negative sentinel-node biopsy and without regression. Early sentinel-node biopsy is associated with worse survival in patients with cutaneous melanoma. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Comparison of closed-chest drainage with rib resection closed drainage for treatment of chronic tuberculous empyema

    PubMed Central

    Fang, Yong; Xiao, Heping; Hu, Haili

    2018-01-01

    Background This study aimed to compare the efficacy of closed-chest drainage with rib resection closed drainage of chronic tuberculous empyema. Methods This retrospective study reviewed 86 patients with tuberculous empyema in Shanghai Pulmonary Hospital from August 2010 to November 2015. Among these included patients, 22 patients received closed-chest drainage, and 64 patients received rib resection closed drainage. Results The results showed that after intercostal chest closed drain treatment, 2 (9.09%) patients were recovery, 13 (59.09%) patients had significantly curative effect, 6 (27.27%) patients had partly curative effect, and 1 (4.55%) patient had negative effect. After treatment of rib resection closed drainage, 9 (14.06%) patients were successfully recovery, 31 (48.44%) patients had significantly curative effect, 19 (29.69%) patients had partly curative effect, and 5 (7.81%) patients had negative effect. There was no significant difference in the curative effect (P>0.05), while the average catheterization time of rib resection closed drainage (130.05±13.12 days) was significant longer than that (126.14±36.84 days) in course of intercostal chest closed drain (P<0.05). Conclusions This study had demonstrated that closed-chest drainage was an effective procedure for treating empyema in young patients. It was less invasive than rib resection closed drainage and was associated with less severe pain. We advocated closed-chest drainage for the majority of young patients with empyema, except for those with other diseases. PMID:29600066

  7. SENTINEL-1/2 Data for Ship Traffic Monitoring on the Danube River

    NASA Astrophysics Data System (ADS)

    Negula, I. Dana; Poenaru, V. D.; Olteanu, V. G.; Badea, A.

    2016-06-01

    After a long period of drought, the water level of the Danube River has significantly dropped especially on the Romanian sector, in July-August 2015. Danube reached the lowest water level recorded in the last 12 years, causing the blockage of the ships in the sector located close to Zimnicea Harbour. The rising sand banks in the navigable channel congested the commercial traffic for a few days with more than 100 ships involved. The monitoring of the decreasing water level and the traffic jam was performed based on Sentinel-1 and Sentinel-2 free data provided by the European Space Agency and the European Commission within the Copernicus Programme. Specific processing methods (calibration, speckle filtering, geocoding, change detection, image classification, principal component analysis, etc.) were applied in order to generate useful products that the responsible authorities could benefit from. The Sentinel data yielded good results for water mask extraction and ships detection. The analysis continued after the closure of the crisis situation when the water reached the nominal level again. The results indicate that Sentinel data can be successfully used for ship traffic monitoring, building the foundation of future endeavours for a durable monitoring of the Danube River.

  8. Analysis of signal-dependent sensor noise on JPEG 2000-compressed Sentinel-2 multi-spectral images

    NASA Astrophysics Data System (ADS)

    Uss, M.; Vozel, B.; Lukin, V.; Chehdi, K.

    2017-10-01

    The processing chain of Sentinel-2 MultiSpectral Instrument (MSI) data involves filtering and compression stages that modify MSI sensor noise. As a result, noise in Sentinel-2 Level-1C data distributed to users becomes processed. We demonstrate that processed noise variance model is bivariate: noise variance depends on image intensity (caused by signal-dependency of photon counting detectors) and signal-to-noise ratio (SNR; caused by filtering/compression). To provide information on processed noise parameters, which is missing in Sentinel-2 metadata, we propose to use blind noise parameter estimation approach. Existing methods are restricted to univariate noise model. Therefore, we propose extension of existing vcNI+fBm blind noise parameter estimation method to multivariate noise model, mvcNI+fBm, and apply it to each band of Sentinel-2A data. Obtained results clearly demonstrate that noise variance is affected by filtering/compression for SNR less than about 15. Processed noise variance is reduced by a factor of 2 - 5 in homogeneous areas as compared to noise variance for high SNR values. Estimate of noise variance model parameters are provided for each Sentinel-2A band. Sentinel-2A MSI Level-1C noise models obtained in this paper could be useful for end users and researchers working in a variety of remote sensing applications.

  9. Mining Land Subsidence Monitoring Using SENTINEL-1 SAR Data

    NASA Astrophysics Data System (ADS)

    Yuan, W.; Wang, Q.; Fan, J.; Li, H.

    2017-09-01

    In this paper, DInSAR technique was used to monitor land subsidence in mining area. The study area was selected in the coal mine area located in Yuanbaoshan District, Chifeng City, and Sentinel-1 data were used to carry out DInSAR techniqu. We analyzed the interferometric results by Sentinel-1 data from December 2015 to May 2016. Through the comparison of the results of DInSAR technique and the location of the mine on the optical images, it is shown that DInSAR technique can be used to effectively monitor the land subsidence caused by underground mining, and it is an effective tool for law enforcement of over-mining.

  10. Immune cell profile of sentinel lymph nodes in patients with malignant melanoma – FOXP3+ cell density in cases with positive sentinel node status is associated with unfavorable clinical outcome

    PubMed Central

    2013-01-01

    Background Besides being a preferential site of early metastasis, the sentinel lymph node (SLN) is also a privileged site of T-cell priming, and may thus be an appropriate target for investigating cell types involved in antitumor immune reactions. Methods In this retrospective study we determined the prevalence of OX40+ activated T lymphocytes, FOXP3+ (forkhead box P3) regulatory T cells, DC-LAMP+ (dendritic cell-lysosomal associated membrane protein) mature dendritic cells (DCs) and CD123+ plasmacytoid DCs by immunohistochemistry in 100 SLNs from 60 melanoma patients. Density values of each cell type in SLNs were compared to those in non-sentinel nodes obtained from block dissections (n = 37), and analyzed with regard to associations with clinicopathological parameters and disease outcome. Results Sentinel nodes showed elevated amount of all cell types studied in comparison to non-sentinel nodes. Metastatic SLNs had higher density of OX40+ lymphocytes compared to tumor-negative nodes, while no significant difference was observed in the case of the other cell types studied. In patients with positive sentinel node status, high amount of FOXP3+ cells in SLNs was associated with shorter progression-free (P = 0.0011) and overall survival (P = 0.0014), while no significant correlation was found in the case of sentinel-negative patients. The density of OX40+, CD123+ or DC-LAMP+ cells did not show significant association with the outcome of the disease. Conclusions Taken together, our results are compatible with the hypothesis of functional competence of sentinel lymph nodes based on the prevalence of the studied immune cells. The density of FOXP3+ lymphocytes showed association with progression and survival in patients with positive SLN status, while the other immune markers studied did not prove of prognostic importance. These results, together with our previous findings on the prognostic value of activated T cells and mature DCs infiltrating primary

  11. 10 % fluorescein sodium vs 1 % isosulfan blue in breast sentinel lymph node biopsy.

    PubMed

    Ren, Lidong; Liu, Zhao; Liang, Mengdi; Wang, Li; Song, Xingli; Wang, Shui

    2016-11-03

    Sentinel lymph node biopsy (SLNB) is well accepted to be a standard procedure in breast cancer surgery with clinically negative lymph nodes. Isosulfan blue is the first dye approved by the USA Food and Drug Administration for the localization of the lymphatic system. Few alternative tracers have been investigated. In this study, we aimed to compare the differences between 10 % fluorescein sodium and 1 % isosulfan blue in breast sentinel lymph node biopsy and to investigate the feasibility of using 10 % fluorescein sodium as a new dye for breast sentinel lymph node biopsy. A total of 30 New Zealand rabbits were randomly divided into the fluorescein sodium group and the isosulfan blue group (15 rabbits per group). Fluorescein sodium or isosulfan blue was injected subcutaneously into the second pair of mammary areolas. The average fading time of the second lymph nodes in the isosulfan blue group was significantly shorter than that in the fluorescein sodium group. Moreover, the detection rates of SLNs were higher in the fluorescein sodium group than in the isosulfan blue group. No significant differences between the fluorescein sodium group and isosulfan blue group were observed regarding the distances between the detected sentinel lymph nodes and second pair of mammary areolas, the distances between the second lymph nodes and second pair of mammary areolas, the number of detected sentinel lymph nodes and second lymph nodes, the average dyeing time of the sentinel and the second lymph nodes, and the average fading time of the second lymph nodes. In summary, we first reported that fluorescein sodium is a potential new tracer for breast sentinel lymph node biopsy.

  12. Mission Design for NASA's Inner Heliospheric Sentinels and ESA's Solar Orbiter Missions

    NASA Technical Reports Server (NTRS)

    Downing, John; Folta, David; Marr, Greg; Rodriquez-Canabal, Jose; Conde, Rich; Guo, Yanping; Kelley, Jeff; Kirby, Karen

    2007-01-01

    This paper will document the mission design and mission analysis performed for NASA's Inner Heliospheric Sentinels (IHS) and ESA's Solar Orbiter (SolO) missions, which were conceived to be launched on separate expendable launch vehicles. This paper will also document recent efforts to analyze the possibility of launching the Inner Heliospheric Sentinels and Solar Orbiter missions using a single expendable launch vehicle, nominally an Atlas V 551.

  13. Factors Predictive of Sentinel Lymph Node Involvement in Primary Breast Cancer.

    PubMed

    Malter, Wolfram; Hellmich, Martin; Badian, Mayhar; Kirn, Verena; Mallmann, Peter; Krämer, Stefan

    2018-06-01

    Sentinel lymph node biopsy (SLNB) has replaced axillary lymph node dissection (ALND) for axillary staging in patients with early-stage breast cancer. The need for therapeutic ALND is the subject of ongoing debate especially after the publication of the ACOSOG Z0011 trial. In a retrospective trial with univariate and multivariate analyses, factors predictive of sentinel lymph node involvement should be analyzed in order to define tumor characteristics of breast cancer patients, where SLNB should not be spared to receive important indicators for adjuvant treatment decisions (e.g. thoracic wall irradiation after mastectomy with or without reconstruction). Between 2006 and 2010, 1,360 patients with primary breast cancer underwent SLNB with/without ALND with evaluation of tumor localization, multicentricity and multifocality, histological subtype, tumor size, grading, lymphovascular invasion (LVI), and estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 status. These characteristics were retrospectively analyzed in univariate and multivariate logistic regression models to define significant predictive factors for sentinel lymph node involvement. The multivariate analysis demonstrated that tumor size and LVI (p<0.001) were independent predictive factors for metastatic sentinel lymph node involvement in patients with early-stage breast cancer. Because of the increased risk for metastatic involvement of axillary sentinel nodes in cases with larger breast cancer or diagnosis of LVI, patients with these breast cancer characteristics should not be spared from SLNB in a clinically node-negative situation in order to avoid false-negative results with a high potential for wrong indication of primary breast reconstruction or wrong non-indication of necessary post-mastectomy radiation therapy. The prognostic impact of avoidance of axillary staging with SLNB is analyzed in the ongoing prospective INSEMA trial. Copyright© 2018, International

  14. Site-specific lead exposure from lead pellet ingestion in sentinel mallards

    USGS Publications Warehouse

    Rocke, T.E.; Brand, C.J.; Mensik, John G.

    1997-01-01

    We monitored lead poisoning from the ingestion of spent lead pellets in sentinel mallards (Anas platyhrynchos) at the Sacramento National Wildlife Refuge (SNWR), Willows, California for 4 years (1986-89) after the conversion to steel shot for waterfowl hunting on refuges in 1986. Sentinel mallards were held in 1.6-ha enclosures in 1 hunted (P8) and 2 non-hunted (T19 and TF) wetlands. We compared site-specific rates of lead exposure, as determined by periodic measurement of blood lead concentrations, and lead poisoning mortality between wetlands with different lead pellet densities, between seasons, and between male and female sentinels. In 1986, the estimated 2-week rate of lead exposure was significantly higher (P < 0.005) in P8 (43.8%), the wetland with the highest density of spent lead pellets (>2,000,000 pellets/ha), than in those with lower densities of lead pellets, T19 (18.1%; 173,200 pellets/ha) and TF (0.9%; 15,750 pellets/ha). The probability of mortality from lead poisoning was also significantly higher (P < 0.01) in sentinel mallards enclosed in P8 (0.25) than T19 (0) and TF (0) in 1986 and remained significantly higher (P < 0.001) during the 4-year study. Both lead exposure and the probability of lead poisoning mortality in P8 were significantly higher (P < 0.001) in the fall of 1986 (43.8%; 0.25), before hunting season, than in the spring of 1987 (21.6%; 0.04), after hunting season. We found no significant differences in the rates of lead exposure or lead poisoning mortality between male and female sentinel mallards. The results of this study demonstrate that in some locations, lead exposure and lead poisoning in waterfowl will continue to occur despite the conversion to steel shot for waterfowl hunting.

  15. Comparison of Trapping Performance Between the Original BG-Sentinel® Trap and BG-Sentinel 2® Trap (1).

    PubMed

    Arimoto, Hanayo; Harwood, James F; Nunn, Peter J; Richardson, Alec G; Gordon, Scott; Obenauer, Peter J

    2015-12-01

    Recently, the BG-Sentinel® trap (BGS) trap has been reconfigured for increased durability during harsh field conditions. We evaluated the attractiveness of this redesigned trap, BG-Sentinel 2® (BGS2), and its novel granular lure cartridge system relative to the original trap and lure. Granular lures containing different combinations of lactic acid, ammonia, hexanoic acid, and octenol were also evaluated. Lure cartridges with all components except octenol trapped significantly more Aedes albopictus than lures containing octenol. This new granular lure combination and original BG-Lure® system were paired with BGS and BGS2 traps to compare relative attractiveness of the lures and the traps. All evaluations were conducted under field conditions in a suburban neighborhood in northeastern Florida from July to October 2014. Overall, the average numbers of Ae. albopictus collected by BGS or BGS2 were similar regardless of the lure type (i.e., mesh bag versus granules) (P  =  0.56). The functionality and durability of both trap models are discussed.

  16. Drainage networks after wildfire

    USGS Publications Warehouse

    Kinner, D.A.; Moody, J.A.

    2005-01-01

    Predicting runoff and erosion from watersheds burned by wildfires requires an understanding of the three-dimensional structure of both hillslope and channel drainage networks. We investigate the small-and large-scale structures of drainage networks using field studies and computer analysis of 30-m digital elevation model. Topologic variables were derived from a composite 30-m DEM, which included 14 order 6 watersheds within the Pikes Peak batholith. Both topologic and hydraulic variables were measured in the field in two smaller burned watersheds (3.7 and 7.0 hectares) located within one of the order 6 watersheds burned by the 1996 Buffalo Creek Fire in Central Colorado. Horton ratios of topologic variables (stream number, drainage area, stream length, and stream slope) for small-scale and large-scale watersheds are shown to scale geometrically with stream order (i.e., to be scale invariant). However, the ratios derived for the large-scale drainage networks could not be used to predict the rill and gully drainage network structure. Hydraulic variables (width, depth, cross-sectional area, and bed roughness) for small-scale drainage networks were found to be scale invariant across 3 to 4 stream orders. The relation between hydraulic radius and cross-sectional area is similar for rills and gullies, suggesting that their geometry can be treated similarly in hydraulic modeling. Additionally, the rills and gullies have relatively small width-to-depth ratios, implying sidewall friction may be important to the erosion and evolutionary process relative to main stem channels.

  17. Exploring Agricultural Drainage's Influence on Wetland and ...

    EPA Pesticide Factsheets

    Artificial agricultural drainage (i.e. surface ditches or subsurface tile) is an important agricultural management tool. Artificial drainage allows for timely fieldwork and adequate root aeration, resulting in greater crop yields for farmers. This practice is widespread throughout many regions of the United States and the network of artificial drainage is especially extensive in flat, poorly-drained regions like the glaciated Midwest. While beneficial for crop yields, agricultural drains often empty into streams within the natural drainage system. The increased network connectivity may lead to greater contributing area for watersheds, altered hydrology and increased conveyance of pollutants into natural water bodies. While studies and models at broader scales have implicated artificial drainage as an important driver of hydrological shifts and eutrophication, the actual spatial extent of artificial drainage is poorly known. Consequently, metrics of wetland and watershed connectivity within agricultural regions often fail to explicitly include artificial drainage. We use recent agricultural census data, soil drainage data, and land cover data to create estimates of potential agricultural drainage across the United States. We estimate that agricultural drainage in the US is greater than 31 million hectares and is concentrated in the upper Midwest Corn Belt, covering greater than 50% of available land for 114 counties. Estimated drainage values for numerous countie

  18. Manatees as sentinels of marine ecosystem health: are they the 2000-pound canaries?

    USGS Publications Warehouse

    Bonde, R.K.; Aguirre, A.A.; Powell, J.

    2004-01-01

    The order Sirenia is represented by three species of manatees and one species of dugong distributed in tropical and subtropical regions of the world and considered vulnerable to extinction. The sentinel species concept is useful to identify indicators of the environment and may reflect the quality of health in marine ecosystems. The single species approach to evaluate ecological health may provide a series of “snap shots” of environmental changes to determine if animal, human, or ecosystem health may be affected. Under this concept, marine vertebrates may be good integrators of changes over space and time, and excellent sentinels of ecosystem health. Based on their life history, manatees may or may not be ideal sentinels, as they are robust, long-lived species and appear remarkably resilient to natural disease and the effects of human-related injury and trauma. These characteristics might be the result of an efficient and responsive immune system compared to other marine mammals. Although relatively immune to infectious agents, manatees face other potentially serious threats, including epizootic diseases and pollution while in large aggregations. Manatees can serve as excellent sentinels of harmful algal blooms due to their high sensitivity, specifically to brevetoxicosis, which has caused at least two major die-offs in recent times. Threats to manatees worldwide, such as illegal hunting and boat collisions, are increasing. Habitat is being lost at an alarming rate and the full effects of uncontrolled human population growth on the species are unknown. The manatee may serve as a sentinel species, prognosticating the deleterious effects of unhealthy marine and aquatic ecosystems on humans. We have identified a number of critical research needs and opportunities for transdisciplinary collaboration that could help advance the use of the sentinel species concept in marine ecosystem health and monitoring of disease emergence using our knowledge on these magnificent

  19. Lakes as sentinels of climate change

    PubMed Central

    Adrian, Rita; O’Reilly, Catherine M.; Zagarese, Horacio; Baines, Stephen B.; Hessen, Dag O.; Keller, Wendel; Livingstone, David M.; Sommaruga, Ruben; Straile, Dietmar; Van Donk, Ellen; Weyhenmeyer, Gesa A.; Winder, Monika

    2010-01-01

    While there is a general sense that lakes can act as sentinels of climate change, their efficacy has not been thoroughly analyzed. We identified the key response variables within a lake that act as indicators of the effects of climate change on both the lake and the catchment. These variables reflect a wide range of physical, chemical, and biological responses to climate. However, the efficacy of the different indicators is affected by regional response to climate change, characteristics of the catchment, and lake mixing regimes. Thus, particular indicators or combinations of indicators are more effective for different lake types and geographic regions. The extraction of climate signals can be further complicated by the influence of other environmental changes, such as eutrophication or acidification, and the equivalent reverse phenomena, in addition to other land-use influences. In many cases, however, confounding factors can be addressed through analytical tools such as detrending or filtering. Lakes are effective sentinels for climate change because they are sensitive to climate, respond rapidly to change, and integrate information about changes in the catchment. PMID:20396409

  20. A Harmonized Landsat-Sentinel-2 Surface Reflectance product: a resource for Agricultural Monitoring

    NASA Astrophysics Data System (ADS)

    Masek, J. G.; Claverie, M.; Ju, J.; Vermote, E.; Justice, C. O.

    2015-12-01

    The combination of Landsat and Sentinel-2 data offers a unique opportunity to observe globally the land every 2-3 days at medium (<30m) spatial resolution. The Harmonized Landsat-Sentinel-2 (HLS) project is a NASA initiative aiming to produce surface reflectance data from Landsat and Sentinel-2 missions and to deliver them to the community in a combined, seamless form. The HLS will be beneficial for global agricultural monitoring applications that require medium spatial resolution and weekly or more frequent observations. In particular, the provided opportunity to track crop phenology at the scale of individual fields will support detailed mapping of crop type and type-specific vegetation conditions. To create a compatible set of radiometric measurements, the HLS product relies on rigorous pre- and post-launch cross-calibration (Landsat-8 OLI and Sentinel-2 MSI) activities. The processing chain includes the following components: atmospheric correction, cloud/shadow masking, nadir BRDF-adjustment, spectral-adjustment, regridding, and temporal composite. The atmospheric correction and cloud masking is based on the OLI atmospheric correction developed at NASA-GSFC and has been adapted to the MSI data. The BRDF-adjustment is based on a disaggregation technique using MODIS-based BRDF coefficients. The technique has been evaluated using the multi-angular acquisition from the SPOT 4 and 5 (Take5) experiments. The spectral-adjustment relies on a linear regression that has been calibrated and evaluated using synthetic data and surface reflectance processed from a large number of hyperspectral EO-1 Hyperion scenes. Finally, significant effort is placed on product validation and evaluation. The delivered data set will include surface reflectance products at different levels: Using the native gridding, i.e. UTM, 30m for Landsat-8, and UTM, 10-20m for Sentinel-2 Using a common global gridding (Sinusoidal, 30m) Temporal composite (Sinusoidal, 30m, 5-day) During the first year of

  1. Spontaneously removed biliary stent drainage versus T-tube drainage after laparoscopic common bile duct exploration.

    PubMed

    Xu, Yakun; Dong, Chengyong; Ma, Kexin; Long, Fei; Jiang, Keqiu; Shao, Ping; Liang, Rui; Wang, Liming

    2016-09-01

    Several studies have shown the safety and feasibility of laparoscopic common bile duct exploration (LCBDE) as a minimally invasive treatment options for choledocholithiasis. Use of T-tube or biliary stent drainage tube placement after laparoscopic choledochotomy for common bile duct (CBD) stones is still under debate. This study tried to confirm the safety of spontaneously removable biliary stent in the distal CBD after LCBDE to allow choledochus primary closure. A total of 47 patients with choledocholithiasis underwent LCBDE with primary closure and internal drainage using a spontaneously removable biliary stent drainage tube (stent group, N = 22) or T-tube (T-tube group, N = 25). Operative parameters and outcomes are compared. Surgical time, intraoperative blood loss, length of hospital stay, drainage tube removal time, postoperative intestinal function recovery, and cost of treatment were all significantly lower in the stent group as compared to that in the T-tube group (P < 0.05 for all). Otherwise, Bile leakage between the two groups had no significant difference (P > 0.05). The biliary stent drainage tube was excreted spontaneously 4 to 14 days after surgery with the exception of one case, where endoscopic removal of biliary tube was required due to failure of its spontaneous discharge. LCBDE with primary closure and use of spontaneously removable biliary stent drainage showed advantage over the use of traditional T-tube drainage in patients with choledocholithiasis.

  2. Mountain Plant Community Sentinels: AWOL

    NASA Astrophysics Data System (ADS)

    Malanson, G. P.

    2017-12-01

    Mountain plant communities are thought to be sensitive to climate change. Because climatic gradients are steep on mountain slopes, the spatial response of plant communities to climate change should be compressed and easier to detect. These expectations have led to identifying mountain plant communities as sentinels for climate change. This idea has, however, been criticized. Two critiques, for alpine treeline and alpine tundra, are rehearsed and supplemented. The critique of alpine treeline as sentinel is bolstered with new model results on the confounding role of dispersal mechanisms and sensitivity to climatic volatility. In alpine tundra, for which background turnover rates have yet to be established, community composition may reflect environmental gradients only for extremes where effects of climate are most indirect. Both plant communities, while primarily determined by energy at broad scales, may respond to water as a proximate driver at local scales. These plant communities may not be in equilibrium with climate, and differently scaled time lags may mean that ongoing vegetation change may not signal ongoing climate change (or lack thereof). In both cases a double-whammy is created by scale dependence for time lags and for drivers leading to confusion, but these cases present opportunities for insights into basic ecology.

  3. Developments in the Aerosol Layer Height Retrieval Algorithm for the Copernicus Sentinel-4/UVN Instrument

    NASA Astrophysics Data System (ADS)

    Nanda, Swadhin; Sanders, Abram; Veefkind, Pepijn

    2016-04-01

    The Sentinel-4 mission is a part of the European Commission's Copernicus programme, the goal of which is to provide geo-information to manage environmental assets, and to observe, understand and mitigate the effects of the changing climate. The Sentinel-4/UVN instrument design is motivated by the need to monitor trace gas concentrations and aerosols in the atmosphere from a geostationary orbit. The on-board instrument is a high resolution UV-VIS-NIR (UVN) spectrometer system that provides hourly radiance measurements over Europe and northern Africa with a spatial sampling of 8 km. The main application area of Sentinel-4/UVN is air quality. One of the data products that is being developed for Sentinel-4/UVN is the Aerosol Layer Height (ALH). The goal is to determine the height of aerosol plumes with a resolution of better than 0.5 - 1 km. The ALH product thus targets aerosol layers in the free troposphere, such as desert dust, volcanic ash and biomass during plumes. KNMI is assigned with the development of the Aerosol Layer Height (ALH) algorithm. Its heritage is the ALH algorithm developed by Sanders and De Haan (ATBD, 2016) for the TROPOMI instrument on board the Sentinel-5 Precursor mission that is to be launched in June or July 2016 (tentative date). The retrieval algorithm designed so far for the aerosol height product is based on the absorption characteristics of the oxygen-A band (759-770 nm). The algorithm has heritage to the ALH algorithm developed for TROPOMI on the Sentinel 5 precursor satellite. New aspects for Sentinel-4/UVN include the higher resolution (0.116 nm compared to 0.4 for TROPOMI) and hourly observation from the geostationary orbit. The algorithm uses optimal estimation to obtain a spectral fit of the reflectance across absorption band, while assuming a single uniform layer with fixed width to represent the aerosol vertical distribution. The state vector includes amongst other elements the height of this layer and its aerosol optical

  4. What Is a False Negative Sentinel Node Biopsy: Definition, Reasons and Ways to Minimize It?

    PubMed

    Kataria, Kamal; Srivastava, Anurag; Qaiser, Darakhshan

    2016-10-01

    Sentinel node biopsy helps in assessing the involvement of axillary lymph node without the morbidity of full axillary lymph node dissection, namely arm and shoulder pain, paraesthesia and lymphoedema. The various methods described in the literature identify the sentinel lymph nodes in approximately 96 % of cases and associated with a false negativity rate of 5 to 10 %. A false negative sentinel node is defined as the proportion of cases in whom sentinel node biopsy is reported as negative, but the rest of axillary lymph node(s) harbours cancer cells. The possible causes of a false negative sentinel lymph node may be because of blocked lymphatics either by cancer cells or following fibrosis of previous surgery/radiotherapy, and an alternative pathway opens draining the blue dye or isotope to another uninvolved node . The other reasons may be two lymphatic pathways for a tumour area, the one opening to a superficial node and the other in deep nodes. Sometimes, lymphatics do not relay into a node but traverse it going to a higher node. In some patients, the microscopic focus of metastasis inside a lymph node is so small-micrometastasis (i.e. between 0.2 and 2 mm) or isolated tumour cells (i.e. less than 0.2 mm) that is missed by the pathologist. The purpose of this review is to clear some fears lurking in the mind of most surgeons about the false negative sentinel lymph node (FNSLN).

  5. [Feasibility analysis of sentinel lymph node biopsy in patients with breast cancer after local lumpectomy].

    PubMed

    Wang, J; Wang, X; Wang, W Y; Liu, J Q; Xing, Z Y; Wang, X

    2016-07-01

    To explore the feasibility, safety and clinical application value of sentinel lymph node biopsy(SLNB)in patients with breast cancer after local lumpectomy. Clinical data of 195 patients who previously received local lumpectomy from January 2005 to April 2015 were retrospectively analyzed. All the patients with pathologic stage T1-2N0M0 (T1-2N0M0) breast cancer underwent SLNB. Methylene blue, carbon nanoparticles suspension, technetium-99m-labeled dextran, or in combination were used in the SLNB. The interval from lumpectomy to SLNB was 1-91 days(mean, 18.3 days)and the maximum diameter of tumors before first operation was 0.2-4.5 cm (mean, 1.8 cm). The sentinel lymph node was successfully found in all the cases and the detection rate was 100%. 42 patients received axillary lymph node dissection (ALND), 19 patients had pathologically positive sentinel lymph node, with an accuracy rate of 97.6%, sensitivity of 95.0%, false negative rate of 5.0%, and specificity of 100%, and the false positive rate was 0. Logistic regression analysis suggested that the age of patients was significantly associated with sentinel lymph node metastasis after local lumpectomy. For early breast cancer and after breast tumor biopsy, the influence of local lumpectomy on detection rate and accuracy of sentinel lymph node is not significant. Sentinel lymph node biopsy with appropriately chosen tracing technique may still provide a high detection rate and accuracy.

  6. Technique for reliable sentinel node biopsy in squamous cell carcinomas of the floor of mouth.

    PubMed

    Stoeckli, Sandro J; Huebner, Thomas; Huber, Gerhard F; Broglie, Martina A

    2016-09-01

    Applicability of sentinel node biopsy (SNB) for tumors of the floor of mouth (FOM) is controversial. Prospective evaluation of the accuracy of gamma-probe-guided superselective neck dissection of the preglandular triangle of level I for SNB in FOM squamous cell carcinoma (SCC) after preoperative lymphoscintigraphy and single photon emission CT (SPECT)/CT. In total, 22 sentinel lymph nodes were harvested in level I. Eight of 22 (36%) were seen on lymphoscintigraphy and 11 (50%) on SPECT/CT. Eleven sentinel lymph nodes (50%) were only detected intraoperatively. In unilateral tumors, 20% were contralateral, and, in midline tumors, 93% showed bilateral level I sentinel lymph nodes. The false-negative rate was 8.3%, the negative predictive value was 96.4%, and the false-omission rate was 3.6%. The ultimate neck control rate, including salvage treatment, was 100%. SNB in FOM can be reliably performed using the presented surgical technique. Level I exploration, bilaterally in midline tumors, is mandatory irrespective of the visualization of sentinel lymph nodes in other levels. © 2016 Wiley Periodicals, Inc. Head Neck 38: 1367-1372, 2016. © 2016 Wiley Periodicals, Inc.

  7. New NASA Satellite Flood Map of Southeastern Texas (Sentinel-1 Data)

    NASA Image and Video Library

    2017-08-31

    The Advanced Rapid Imaging and Analysis (ARIA) team at NASA's Jet Propulsion Laboratory in Pasadena, California, used synthetic aperture radar imagery from the European Space Agency's (ESA) Sentinel-1 satellite to create this Flood Proxy Map of Southeastern Texas, showing areas that are likely flooded as a result of Hurricane Harvey (light blue pixels). The images used to create the map were taken before (Aug. 5, 2017) and after (Aug. 29, 2017) Hurricane Harvey made landfall. The map covers an area of 155 by 211 miles (250 by 340 kilometers). Each pixel measures about 33 yards (30 meters) across. Local ground observations provided anecdotal preliminary validation. The results were also cross-validated with the ARIA ALOS-2 flood proxy map v0.2. The map should be used as guidance, and may be less reliable over urban areas. Sentinel-1 data were accessed through the Copernicus Open Access Hub. Contains modified Copernicus Sentinel data 2017. https://photojournal.jpl.nasa.gov/catalog/PIA21932

  8. Comparison of natural drainage group and negative drainage groups after total thyroidectomy: prospective randomized controlled study.

    PubMed

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum; Son, Young-Ik

    2013-01-01

    The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. The amount of drainage during the first 24 hours postoperatively was 41.68 ± 3.93 mL in the negative drain group and 25.3 ± 2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19 ± 4.26 mL and natural drain groups 21.53 ± 2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done.

  9. Interval sentinel lymph nodes in melanoma: a digital pathology analysis of Ki67 expression and microvascular density.

    PubMed

    Marinaccio, Christian; Giudice, Giuseppe; Nacchiero, Eleonora; Robusto, Fabio; Opinto, Giuseppina; Lastilla, Gaetano; Maiorano, Eugenio; Ribatti, Domenico

    2016-08-01

    The presence of interval sentinel lymph nodes in melanoma is documented in several studies, but controversies still exist about the management of these lymph nodes. In this study, an immunohistochemical evaluation of tumor cell proliferation and neo-angiogenesis has been performed with the aim of establishing a correlation between these two parameters between positive and negative interval sentinel lymph nodes. This retrospective study reviewed data of 23 patients diagnosed with melanoma. Bioptic specimens of interval sentinel lymph node were retrieved, and immunohistochemical reactions on tissue sections were performed using Ki67 as a marker of proliferation and CD31 as a blood vessel marker for the study of angiogenesis. The entire stained tissue sections for each case were digitized using Aperio Scanscope Cs whole-slide scanning platform and stored as high-resolution images. Image analysis was carried out on three selected fields of equal area using IHC Nuclear and Microvessel analysis algorithms to determine positive Ki67 nuclei and vessel number. Patients were divided into positive and negative interval sentinel lymph node groups, and the positive interval sentinel lymph node group was further divided into interval positive with micrometastasis and interval positive with macrometastasis subgroups. The analysis revealed a significant difference between positive and negative interval sentinel lymph nodes in the percentage of Ki67-positive nuclei and mean vessel number suggestive of an increased cellular proliferation and angiogenesis in positive interval sentinel lymph nodes. Further analysis in the interval positive lymph node group showed a significant difference between micro- and macrometastasis subgroups in the percentage of Ki67-positive nuclei and mean vessel number. Percentage of Ki67-positive nuclei was increased in the macrometastasis subgroup, while mean vessel number was increased in the micrometastasis subgroup. The results of this study suggest

  10. MTF Determination of SENTINEL-4 Detector Arrays

    NASA Astrophysics Data System (ADS)

    Reulke, R.; Sebastian, I.; Williges, C.; Hohn, R.

    2017-05-01

    The Institute for Optical Sensor Systems was involved in many international space projects in recent years. These include, for example, the fokal plane array (FPA) of the hyperspectral sensors ENMAP or Sentinel-4, but also the FPA for the high resolution FPA for Kompsat-3. An important requirement of the customer is the measurement of the detector MTF for different wavelengths. A measuring station under clean room conditions and evaluation algorithms was developed for these measurements. The measurement setup consist of a collimator with slit target in focus for illumination at infinity, a gimbal mounted detector facing an auxiliary lens in front, a halogen lamp with monochromator or filter, as well as optical and electrical ground support equipment. Different targets and therefore also different measurement and data evaluation opportunities are possible with this setup. Examples are slit, edge, pin hole but also a Siemens star. The article describes the measurement setup, the different measuring and evaluation procedures and exemplary results for Sentinel-4 detector.

  11. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience.

    PubMed

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R; Chagpar, Anees B; Killelea, Brigid K; Lannin, Donald R

    2017-01-01

    Background . Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods . Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results . At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1-15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion . Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient.

  12. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience

    PubMed Central

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R.; Chagpar, Anees B.

    2017-01-01

    Background. Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods. Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results. At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1–15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion. Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient. PMID:28492062

  13. Evaluation of automated urban surface water extraction from Sentinel-2A imagery using different water indices

    NASA Astrophysics Data System (ADS)

    Yang, Xiucheng; Chen, Li

    2017-04-01

    Urban surface water is characterized by complex surface continents and small size of water bodies, and the mapping of urban surface water is currently a challenging task. The moderate-resolution remote sensing satellites provide effective ways of monitoring surface water. This study conducts an exploratory evaluation on the performance of the newly available Sentinel-2A multispectral instrument (MSI) imagery for detecting urban surface water. An automatic framework that integrates pixel-level threshold adjustment and object-oriented segmentation is proposed. Based on the automated workflow, different combinations of visible, near infrared, and short-wave infrared bands in Sentinel-2 image via different water indices are first compared. Results show that object-level modified normalized difference water index (MNDWI with band 11) and automated water extraction index are feasible in urban surface water mapping for Sentinel-2 MSI imagery. Moreover, comparative results are obtained utilizing optimal MNDWI from Sentinel-2 and Landsat 8 images, respectively. Consequently, Sentinel-2 MSI achieves the kappa coefficient of 0.92, compared with that of 0.83 from Landsat 8 operational land imager.

  14. The Surveillance and On-demand Sentinel-1 SBAS Services on the Geohazards Exploitation Platforms

    NASA Astrophysics Data System (ADS)

    Casu, F.; de Luca, C.; Zinno, I.; Manunta, M.; Lanari, R.

    2017-12-01

    The Geohazards Exploitation Platform (GEP) is an ESA R&D activity of the EO ground segment to demonstrate the benefit of new technologies for large scale processing of EO data. GEP aims at providing on-demand processing services for specific user needs, as well as systematic processing services to address the need of the geohazards community for common information layers and, finally, to integrate newly developed processors for scientists and other expert users. In this context, a crucial role is played by the recently launched Sentinel-1 (S1) constellation that, with its global acquisition policy, has flooded the scientific community with a huge amount of data acquired over large part of the Earth on a regular basis (down to 6-days with both Sentinel-1A and 1B passes). The Sentinel-1 data, as part of the European Copernicus program, are openly and freely accessible, thus fostering their use for the development of automated and systematic tools for Earth surface monitoring. In particular, due to their specific SAR Interferometry (InSAR) design, Sentinel-1 satellites can be exploited to build up operational services for the easy and rapid generation of advanced InSAR products useful for risk management and natural hazard monitoring. In this work we present the activities carried out for the development, integration, and deployment of two SBAS Sentinel-1 services of CNR-IREA within the GEP framework, namely the Surveillance and On-demand services. The Surveillance service consists on the systematic and automatic processing of Sentinel-1 data over selected Areas of Interest (AoI) to generate updated surface displacement time series via the SBAS-InSAR algorithm. We built up a system that is automatically triggered by every new Sentinel-1 acquisition over the AoI, once it is available on the S1 catalogue. Then, the system processes the new acquisitions only, thus saving storage space and computing time. The processing, which relies on the Parallel version of the SBAS (P

  15. Preoperative biliary drainage for periampullary tumors causing obstructive jaundice; DRainage vs. (direct) OPeration (DROP-trial).

    PubMed

    van der Gaag, Niels A; de Castro, Steve M M; Rauws, Erik A J; Bruno, Marco J; van Eijck, Casper H J; Kuipers, Ernst J; Gerritsen, Josephus J G M; Rutten, Jan-Paul; Greve, Jan Willem; Hesselink, Erik J; Klinkenbijl, Jean H G; Rinkes, Inne H M Borel; Boerma, Djamila; Bonsing, Bert A; van Laarhoven, Cees J; Kubben, Frank J G M; van der Harst, Erwin; Sosef, Meindert N; Bosscha, Koop; de Hingh, Ignace H J T; Th de Wit, Laurens; van Delden, Otto M; Busch, Olivier R C; van Gulik, Thomas M; Bossuyt, Patrick M M; Gouma, Dirk J

    2007-03-12

    Surgery in patients with obstructive jaundice caused by a periampullary (pancreas, papilla, distal bile duct) tumor is associated with a higher risk of postoperative complications than in non-jaundiced patients. Preoperative biliary drainage was introduced in an attempt to improve the general condition and thus reduce postoperative morbidity and mortality. Early studies showed a reduction in morbidity. However, more recently the focus has shifted towards the negative effects of drainage, such as an increase of infectious complications. Whether biliary drainage should always be performed in jaundiced patients remains controversial. The randomized controlled multicenter DROP-trial (DRainage vs. Operation) was conceived to compare the outcome of a 'preoperative biliary drainage strategy' (standard strategy) with that of an 'early-surgery' strategy, with respect to the incidence of severe complications (primary-outcome measure), hospital stay, number of invasive diagnostic tests, costs, and quality of life. Patients with obstructive jaundice due to a periampullary tumor, eligible for exploration after staging with CT scan, and scheduled to undergo a "curative" resection, will be randomized to either "early surgical treatment" (within one week) or "preoperative biliary drainage" (for 4 weeks) and subsequent surgical treatment (standard treatment). Primary outcome measure is the percentage of severe complications up to 90 days after surgery. The sample size calculation is based on the equivalence design for the primary outcome measure. If equivalence is found, the comparison of the secondary outcomes will be essential in selecting the preferred strategy. Based on a 40% complication rate for early surgical treatment and 48% for preoperative drainage, equivalence is taken to be demonstrated if the percentage of severe complications with early surgical treatment is not more than 10% higher compared to standard treatment: preoperative biliary drainage. Accounting for a 10

  16. Intraoperative Fluorescence Imaging for Detection of Sentinel Lymph Nodes and Lymphatic Vessels during Open Prostatectomy using Indocyanine Green.

    PubMed

    Yuen, Keiji; Miura, Tetsuya; Sakai, Iori; Kiyosue, Akiko; Yamashita, Masuo

    2015-08-01

    We investigated the feasibility and validity of intraoperative fluorescence imaging using indocyanine green for the detection of sentinel lymph nodes and lymphatic vessels during open prostatectomy. Indocyanine green was injected into the prostate under transrectal ultrasound guidance just before surgery. Intraoperative fluorescence imaging was performed using a near-infrared camera system in 66 consecutive patients with clinically localized prostate cancer after a 10-patient pilot test to optimize indocyanine green dosing, observation timing and injection method. Lymphatic vessels were visualized and followed to identify the sentinel lymph nodes. Confirmatory pelvic lymph node dissection including all fluorescent nodes and open radical prostatectomy were performed in all patients. Lymphatic vessels were successfully visualized in 65 patients (98%) and sentinel lymph nodes in 64 patients (97%). Sentinel lymph nodes were located in the obturator fossa, internal and external iliac regions, and rarely in the common iliac and presacral regions. A median of 4 sentinel lymph nodes per patient was detected. Three lymphatic pathways, the paravesical, internal and lateral routes, were identified. Pathological examination revealed metastases to 9 sentinel lymph nodes in 6 patients (9%). All pathologically positive lymph nodes were detected as sentinel lymph nodes using this imaging. No adverse reactions due to the use of indocyanine green were observed. Intraoperative fluorescence imaging using indocyanine green during open prostatectomy enables the detection of lymphatic vessels and sentinel lymph nodes with high sensitivity. This novel method is technically feasible, safe and easy to apply with minimal additional operative time. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Percutaneous biliary drainage for high obstruction.

    PubMed

    Barth, K H

    1990-11-01

    PBD is the preferred route of palliative drainage for patients with high biliary obstruction. The frequency of bifurcational obstruction in this setting requires familiarity with drainages from both the right and the left transhepatic approach. The preferred right transhepatic approach is fluoroscopically guided; on the left, ultrasonography is the guidance of choice. Large caliber drainage catheters are required, and dilatation of the necessary transhepatic tracts is extremely painful unless adequate inhalation anesthesia or, preferably, epidural anesthesia, is provided. Long-term biliary drainage requires a choice between internal-external external drainage catheters and endoprostheses that is made by considering the patient's life expectancy and his or her adjustment to a stent extending to the outside. The feasibility of corrective procedures if an internal-external drainage catheter or an endoprosthesis becomes blocked needs to be considered before definitive placement. The interventional radiologist becomes intimately involved in the follow-up care of patients and frequently has to direct appropriate patient evaluation. Familiarity with antibiotic regimens is important.

  18. Comparison of Natural Drainage Group and Negative Drainage Groups after Total Thyroidectomy: Prospective Randomized Controlled Study

    PubMed Central

    Woo, Seung Hoon; Kim, Jin Pyeong; Park, Jung Je; Shim, Hyun Seok; Lee, Sang Ha; Lee, Ho Joong; Won, Seong Jun; Son, Hee Young; Kim, Rock Bum

    2013-01-01

    Purpose The aim of this study was to compare a negative pressure drain with a natural drain in order to determine whether a negative pressure drainage tube causes an increase in the drainage volume. Materials and Methods Sixty-two patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC) were enrolled in the study between March 2010 and August 2010 at Gyeongsang National University Hospital. The patients were prospectively and randomly assigned to two groups, a negative pressure drainage group (n=32) and natural drainage group (n=30). Every 3 hours, the volume of drainage was checked in the two groups until the tube was removed. Results The amount of drainage during the first 24 hours postoperatively was 41.68±3.93 mL in the negative drain group and 25.3±2.68 mL in the natural drain group (p<0.001). After 24 additional hours, the negative drain group was 35.19±4.26 mL and natural drain groups 21.53±2.90 mL (p<0.001). However, the drainage at postoperative day 3 was not statistically different between the two groups. In addition, the vocal cord palsy and temporary and permanent hypocalcemia were not different between the two groups. Conclusion These results indicate that a negative pressure drain may increase the amount of drainage during the first 24-48 hours postoperatively. Therefore, it is not necessary to place a closed suction drain when only a total thyroidectomy is done. PMID:23225820

  19. Enhancements to the Sentinel Fireball Network Video Software

    NASA Astrophysics Data System (ADS)

    Watson, Wayne

    2009-05-01

    The Sentinel Fireball Network that supports meteor imaging of bright meteors (fireballs) has been in existence for over ten years. Nearly five years ago it moved from gathering meteor data with a camera and VCR video tape to a fisheye lens attached to a hardware device, the Sentinel box, which allowed meteor data to be recorded on a PC operating under real-time Linux. In 2006, that software, sentuser, was made available on Apple, Linux, and Window operating systems using the Python computer language. It provides basic video and management functionality and a small amount of analytic software capability. This paper describes the new and attractive future features of the software, and, additionally, it reviews some of the research and networks from the past and present using video equipment to collect and analyze fireball data that have applicability to sentuser.

  20. Arterial Pulsations cannot Drive Intramural Periarterial Drainage: Significance for Aβ Drainage

    PubMed Central

    Diem, Alexandra K.; MacGregor Sharp, Matthew; Gatherer, Maureen; Bressloff, Neil W.; Carare, Roxana O.; Richardson, Giles

    2017-01-01

    Alzheimer's Disease (AD) is the most common form of dementia and to date there is no cure or efficient prophylaxis. The cognitive decline correlates with the accumulation of amyloid-β (Aβ) in the walls of capillaries and arteries. Our group has demonstrated that interstitial fluid and Aβ are eliminated from the brain along the basement membranes of capillaries and arteries, the intramural periarterial drainage (IPAD) pathway. With advancing age and arteriosclerosis, the stiffness of arterial walls, this pathway fails in its function and Aβ accumulates in the walls of arteries. In this study we tested the hypothesis that arterial pulsations drive IPAD and that a valve mechanism ensures the net drainage in a direction opposite to that of the blood flow. This hypothesis was tested using a mathematical model of the drainage mechanism. We demonstrate firstly that arterial pulsations are not strong enough to produce drainage velocities comparable to experimental observations. Secondly, we demonstrate that a valve mechanism such as directional permeability of the IPAD pathway is necessary to achieve a net reverse flow. The mathematical simulation results are confirmed by assessing the pattern of IPAD in mice using pulse modulators, showing no significant alteration of IPAD. Our results indicate that forces other than the cardiac pulsations are responsible for efficient IPAD. PMID:28883786

  1. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Drainage systems. 3280.610 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Plumbing Systems § 3280.610 Drainage systems. (a) General. (1) Each fixture directly connected to the drainage system shall be installed with a...

  2. Sentinel-1 Contribution to Monitoring Maritime Activity in the Arctic

    NASA Astrophysics Data System (ADS)

    Santamaria, Carlos; Greidanus, Harm; Fournier, Melanie; Eriksen, Torkild; Vespe, Michele; Alvarez, Marlene; Arguedas, Virginia Fernandez; Delaney, Conor; Argentieri, Pietro

    2016-08-01

    This paper presents results on the use of Sentinel-1 combined with satellite AIS to monitor maritime activity in the Arctic. Such activities are expected to increase, even if not uniformly across the Arctic, as the ice cover in the region retreats due to changes in climate. The objectives of monitoring efforts in the region can vary from country to country, but are generally related to increasing awareness on non- cooperative, small and cruise ships, fisheries, safety at sea, and Search and Rescue. A ship monitoring study has been conducted, involving more than 2,000 Sentinel-1 images acquired during one year in the central Arctic, where the ship densities are high. The main challenges to SAR-based monitoring in this area are described, solutions for some of them are proposed, and analyses of the results are shown. With the high detection thresholds needed to prevent false alarms from sea ice, 16% of the ships detected overall in the Sentinel-1 images have not been correlated to AIS- transmitting ships, and 48% of the AIS-transmitting ships are not correlated to ships detected in the images.

  3. The use of isotope injections in sentinel node biopsy for breast cancer: are the 1- and 2-day protocols equally effective?

    PubMed

    Dodia, Nazera; El-Sharief, Deena; Kirwan, Cliona C

    2015-01-01

    Sentinel lymph nodes are mapped using (99m)Technetium, injected on day of surgery (1-day protocol) or day before (2-day protocol). This retrospective cohort study compares efficacy between the two protocols. Histopathology for all unilateral sentinel lymph node biopsies (March 2012-March 2013) in a single centre were reviewed. Number of sentinel lymph nodes, non-sentinel lymph nodes and pathology was compared. 2/270 (0.7 %) in 1-day protocol and 8/192 (4 %) in 2-day protocol had no sentinel lymph nodes removed (p = 0.02). The median (range) number of sentinel lymph nodes removed per patient was 2 (0-7) and 1 (0-11) in the 1- and 2-day protocols respectively (p = 0.08). There was a trend for removing more non-sentinel lymph nodes in 2-day protocol [1-day: 52/270 (19 %); 2-day: 50/192 (26 %), p = 0.07]. Using 2-day, sentinel lymph node identification failure rate is higher, although within acceptable rates. The 1 and 2 day protocols are both effective, therefore choice of protocol should be driven by patient convenience and hospital efficiency. However, this study raises the possibility that 1-day may be preferable when higher sentinel lymph node count is beneficial, for example following neoadjuvant chemotherapy.

  4. Comparison of Landsat-8 and Sentinel-2A reflectance and normalized difference vegetation index

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Roy, D. P.; Yan, L.; Li, Z.; Huang, H.

    2017-12-01

    The moderate spatial resolution satellite data from the polar-orbiting Landsat-8 (launched 2013) and Sentinel-2A (launched 2015) sensors provide 10 m to 30 m multi-spectral global coverage with a better than 5-day revisit. Although a national laboratory traceable cross-calibration comparison of the Landsat-8 Operational Land Imager (OLI) and the Sentinel-2A MultiSpectral Instrument (MSI) was undertaken pre-launch, there are a number of other sensor differences, notably due to spectral, spatial and angular differences. To examine these in a comprehensive way, Landsat-8 and Sentinel-2A data for approximately 20° × 10° of southern Africa acquired in the summer (January to March) and winter (July to September) of 2016 were compared. Only Landsat-8 and Sentinel-2A observations acquired within one-day apart were considered. The sensor data were registered and then each orbit projected into 30 m fixed global Web Enabled Landsat Data (GWELD) tiles defined in the MODIS sinusoidal equal area projection. Only corresponding sensor observations of each 30 m tile pixel that were flagged as cloud and snow-free, unsaturated, and that had no significant change in their one day separation, were compared. Both the Landsat-8 and Sentinel-2A data were atmospherically corrected using the Landsat Surface Reflectance Code (LaSRC) and were also corrected to nadir BRDF adjusted reflectance (NBAR). Top of atmosphere and surface reflectance for the spectrally corresponding visible, near infrared and shortwave infrared OLI and MSI bands, and derived normalized difference vegetation index (NDVI), were compared and their differences quantified using regression analyses. The resulting statistical transformations may be used to improve the consistency between the Landsat-8 OLI and Sentinel-2A MSI data. The importance and sensitivity of the results to correct filtering, atmospheric correction and adjustment to NBAR is demonstrated.

  5. Portable gamma camera guidance in sentinel lymph node biopsy: prospective observational study of consecutive cases.

    PubMed

    Peral Rubio, F; de La Riva, P; Moreno-Ramírez, D; Ferrándiz-Pulido, L

    2015-06-01

    Sentinel lymph node biopsy is the most important tool available for node staging in patients with melanoma. To analyze sentinel lymph node detection and dissection with radio guidance from a portable gamma camera. To assess the number of complications attributable to this biopsy technique. Prospective observational study of a consecutive series of patients undergoing radioguided sentinel lymph node biopsy. We analyzed agreement between nodes detected by presurgical lymphography, those detected by the gamma camera, and those finally dissected. A total of 29 patients (17 women [62.5%] and 12 men [37.5%]) were enrolled. The mean age was 52.6 years (range, 26-82 years). The sentinel node was dissected from all patients; secondary nodes were dissected from some. In 16 cases (55.2%), there was agreement between the number of nodes detected by lymphography, those detected by the gamma camera, and those finally dissected. The only complications observed were seromas (3.64%). No cases of wound dehiscence, infection, hematoma, or hemorrhage were observed. Portable gamma-camera radio guidance may be of use in improving the detection and dissection of sentinel lymph nodes and may also reduce complications. These goals are essential in a procedure whose purpose is melanoma staging. Copyright © 2014 Elsevier España, S.L.U. and AEDV. All rights reserved.

  6. Application of carbon nanoparticles in laparoscopic sentinel lymph node detection in patients with early-stage cervical cancer.

    PubMed

    Lu, Yan; Wei, Jin-Ying; Yao, De-Sheng; Pan, Zhong-Mian; Yao, Yao

    2017-01-01

    To investigate the value of carbon nanoparticles in identifying sentinel lymph nodes in early-stage cervical cancer. From January 2014 to January 2016, 40 patients with cervical cancer stage IA2-IIA, based on the International Federation of Gynecology and Obstetrics (FIGO) 2009 criteria, were included in this study. The normal cervix around the tumor was injected with a total of 1 mL of carbon nanoparticles (CNP)at 3 and 9 o'clock. All patients then underwent laparoscopic pelvic lymph node dissection and radical hysterectomy. The black-dyed sentinel lymph nodes were removed for routine pathological examination and immunohistochemical staining. Among the 40 patients, 38 patients had at least one sentinel lymph node (SLN). The detection rate was 95% (38/40). One hundred seventy-three SLNs were detected with an average of 3.9 SLNs per side. 25 positive lymph nodes, which included 21 positive SLNs, were detected in 8 (20%) patients. Sentinel lymph nodes were localized in the obturator (47.97%), internal lilac (13.87%), external lilac (26.59%), parametrial (1.16%), and common iliac (8.67%) regions. The sensitivity of the SLN detection was 100% (5/5), the accuracy was 97.37% (37/38), and the negative predictive value was 100. 0% and the false negative rate was 0%. Sentinel lymph nodes can be used to accurately predict the pathological state of pelvic lymph nodes in early cervical cancer. The detection rates and accuracy of sentinel lymph node were high. Carbon nanoparticles can be used to trace the sentinel lymph node in early cervical cancer.

  7. Comparison of SPECT/CT and Planar Lympho-scintigraphy in Sentinel Node Biopsies of Oral Cavity Squamous Cell Carcinomas.

    PubMed

    Chandra, Piyush; Dhake, Sanket; Shah, Sneha; Agrawal, Archi; Purandare, Nilendu; Rangarajan, Venkatesh

    2017-01-01

    Evidence supporting the use of Sentinel node biopsy (SNB) for nodal staging of early oral squamous cell carcinomas (OSCC) appears to be very promising. Pre-operative lymphatic mapping using planar lymphoscinitigraphy (PL) with or without SPECT/CT in the SNB procedure is useful in sentinel node localization and for planning appropriate surgery. Recently, a large prospective multi-centric study evaluating SNB in cutaneous melanoma, breast and pelvic malignancies, demonstrated that adding SPECT to PL leads to surgical adjustments in a considerable number of patients. Our aim of this study was to evaluate the incremental value of additional SPECT/CT over PL alone in SNB for OSCC. This was a retrospective analysis of 44 patients (40- tongue, 4- buccal mucosa) with T1-T2, clinically N0 oral cavity SCC who underwent sentinel node biopsy procedure. PL and SPECT lymphoscinitigraphy images were compared for pre-operative mapping of sentinel nodes. Using a handheld gamma probe, a total of 179 sentinel nodes were harvested, with a mean of 4.06 per patient. PL revealed 75 hotspots with a mean of 1.70 per patient, and SPECT/CT revealed 92 hotspots with a mean of 2.09 per patient. Additional hotpots were identified in 14 patients on SPECT/CT, which included 4 patients, where PL did not detect any sentinel nodes. Pre-operative SPECT/CT in addition to planar lympho-scinitigraphy in sentinel node biopsies of oral cavity SCC detects more number of sentinel nodes compared to planar imaging alone. The higher sensitivity of SPECT combined with better anatomical localization using diagnostic CT may further improve the precision of SNB procedure.

  8. Sentinel Lymphadenectomy in Vulvar Cancer Using Near-Infrared Fluorescence From Indocyanine Green Compared With Technetium 99m Nanocolloid.

    PubMed

    Soergel, Philipp; Hertel, Hermann; Nacke, Anna Kaarina; Klapdor, Rüdiger; Derlin, Thorsten; Hillemanns, Peter

    2017-05-01

    Nowadays, sentinel diagnostic is performed using technetium 99m (Tc) nanocolloid as a radioactive marker and sometimes patent blue. In the last years, indocyanine green has been evaluated for sentinel diagnostic in different tumor entities. Indocyanine green is a fluorescent molecule that emits a light signal in the near-infrared band after excitation. Our study aimed to evaluate indocyanine green compared with the criterion-standard Tc-nanocolloid. We included patients with primary, unifocal vulvar cancer of less than 4 cm with clinically node-negative groins in this prospective trial. Sentinel diagnostic was carried out using Tc-nanocolloid, indocyanine green, and patent blue. We examined each groin for light signals from the near-infrared band, for radioactivity, and for blue staining. A sentinel lymph node was defined as a Tc-nanocolloid-positive lymph node. All sentinel lymph nodes and all additional blue or fluorescent lymph nodes were excised and tested and then sent for histologic examination. In all, 27 patients were included in whom we found 91 sentinel lymph nodes in 52 groins. All these lymph nodes were positive for indocyanine green, also giving a sensitivity of 100% (95% confidence interval [CI], 96.0%-100%) compared with Tc-nanocolloid. Eight additional lymph nodes showed indocyanine green fluorescence but no Tc positivity, so that the positive predictive value was 91.9% (95% confidence interval, 84.6%-96.5%). In 1 patient, a false-negative sentinel missed by all 3 modalities was found. Our results show that indocyanine green is a promising approach for inguinal sentinel identification in vulvar cancer with a similar sensitivity as radioactive Tc-nanocolloid and worth to be evaluated in further studies.

  9. Experimental use of high density polyethylene drainage pipe as a cross roadway drainage structure.

    DOT National Transportation Integrated Search

    2001-01-01

    Adequate drainage is one of the most important requirements in the reconstruction of a highway. Often it represents an appreciable expense of construction. In some applications installation costs may be reduced by the use of lighter weight drainage p...

  10. High-Resolution Enhanced Product based on SMAP Active-Passive Approach using Sentinel 1A and 1B SAR Data

    NASA Astrophysics Data System (ADS)

    Das, N. N.; Entekhabi, D.; Dunbar, R. S.; Colliander, A.; Kim, S.; Yueh, S. H.

    2017-12-01

    NASA's Soil Moisture Active Passive (SMAP) mission was launched on January 31st, 2015. SMAP utilizes an L-band radar and radiometer sharing a rotating 6-meter mesh reflector antenna. However, on July 7th, 2015, the SMAP radar encountered an anomaly and is currently inoperable. During the SMAP post-radar phase, many ways are explored to recover the high-resolution soil moisture capability of the SMAP mission. One of the feasible approaches is to substitute the SMAP radar with other available SAR data. Sentinel 1A/1B SAR data is found more suitable for combining with the SMAP radiometer data because of almost similar orbit configuration that allow overlapping of their swaths with minimal time difference that is key to the SMAP active-passive algorithm. The Sentinel SDV mode acquisition also provide the co-pol and x-pol observations required for the SMAP active-passive algorithm. Some differences do exist between the SMAP SAR data and Sentinel SAR data, they are mainly: 1) Sentinel has C-band SAR and SMAP is L-band; 2) Sentinel has multi incidence angle within its swath, where as SMAP has single incidence angle; and 3) Sentinel swath width is 300 km as compare to SMAP 1000 km swath width. On any given day, the narrow swath width of the Sentinel observations will significantly reduce the spatial coverage of SMAP active-passive approach as compared to the SMAP swath coverage. The temporal resolution (revisit interval) is also degraded from 3-days to 12-days when Sentinel 1A/1B data is used. One bright side of using Sentinel 1A/1B data in the SMAP active-passive algorithm is the potential of obtaining the disaggregated brightness temperature and soil moisture at much finer spatial resolutions of 3 km and 9 km with optimal accuracy. The Beta version of SMAP-Sentinel Active-Passive high-resolution product will be made available to public in September 2017.

  11. Endoscopic Gallbladder Drainage for Acute Cholecystitis

    PubMed Central

    Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica

    2015-01-01

    Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125

  12. Illinois drainage water management demonstration project

    USGS Publications Warehouse

    Pitts, D.J.; Cooke, R.; Terrio, P.J.; ,

    2004-01-01

    Due to naturally high water tables and flat topography, there are approximately 4 million ha (10 million ac) of farmland artificially drained with subsurface (tile) systems in Illinois. Subsurface drainage is practiced to insure trafficable field conditions for farm equipment and to reduce crop stress from excess water within the root zone. Although drainage is essential for economic crop production, there have been some significant environmental costs. Tile drainage systems tend to intercept nutrient (nitrate) rich soil-water and shunt it to surface water. Data from numerous monitoring studies have shown that a significant amount of the total nitrate load in Illinois is being delivered to surface water from tile drainage systems. In Illinois, these drainage systems are typically installed without control mechanisms and allow the soil to drain whenever the water table is above the elevation of the tile outlet. An assessment of water quality in the tile drained areas of Illinois showed that approximately 50 percent of the nitrate load was being delivered through the tile systems during the fallow period when there was no production need for drainage to occur. In 1998, a demonstration project to introduce drainage water management to producers in Illinois was initiated by NRCS4 An initial aspect of the project was to identify producers that were willing to manage their drainage system to create a raised water table during the fallow (November-March) period. Financial assistance from two federal programs was used to assist producers in retrofitting the existing drainage systems with control structures. Growers were also provided guidance on the management of the structures for both water quality and production benefits. Some of the retrofitted systems were monitored to determine the effect of the practice on water quality. This paper provides background on the water quality impacts of tile drainage in Illinois, the status of the demonstration project, preliminary

  13. Preoperative lymphoscintigraphy and tumor histologic grade are associated with surgical detection of the sentinel lymph node.

    PubMed

    Arias Ortega, M; Torres Sousa, M Y; González García, B; Pardo García, R; González López, A; Delgado Portela, M

    2014-01-01

    To study which variables involved in the process of selective sentinel node biopsy (SSNB) influence the intraoperative detection of the sentinel lymph node. This was a prospective cross-sectional study in 210 patients (mean age, 54 years) diagnosed with breast cancer who underwent SSNB. We recorded clinical, radiological, radioisotope administration, surgical, and histological data as well as follow-up data. We did a descriptive analysis of the data and an associative analysis using multivariable regression. Deep injection alone was the most common route of radioisotope administration (72.7%). Most lesions were palpable (57.1%), presented as nodules (67.1%), measured less than 2 cm in diameter (64.8%), were located in the upper outer quadrant (49.1%), were ductal carcinomas (85.7%), were accompanied by infiltration (66.2%), and had a histologic grade of differentiation of ii (44.8%). Preoperative scintigraphy detected the sentinel node in 97.6% of cases and 95.7% were detected during the operation. One axillary relapse was observed. In the associative study, the variables "preoperative lymphoscintigraphy" and "histologic grade of differentiation of the tumor" were significantly associated with the detection of the sentinel lymph node during the operation. The probability of not detecting the sentinel lymph node during the surgical intervention is higher in patients with high histologic grade tumors or in patients in whom preoperative lymphoscintigraphy failed to detect the sentinel node. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  14. Inventory of drainage wells and potential sources of contaminants to drainage-well inflow in Southwest Orlando, Orange County, Florida

    USGS Publications Warehouse

    Taylor, George Fred

    1993-01-01

    Potential sources of contaminants that could pose a threat to drainage-well inflow and to water in the Floridan aquifer system in southwest Orlando, Florida, were studied between October and December 1990. Drainage wells and public-supply wells were inventoried in a 14-square-mile area, and available data on land use and activities within each drainage well basin were tabulated. Three public-supply wells (tapping the Lower Floridan aquifer) and 38 drainage wells (open to the Upper Floridan aquifer) were located in 17 drainage basins within the study area. The primary sources of drainage-well inflow are lake overflow, street runoff, seepage from the surficial aquifer system, and process-wastewater disposal. Drainage-well inflow from a variety of ares, including resi- dential, commercial, undeveloped, paved, and industrial areas, are potential sources of con- taminants. The four general types of possible contaminants to drainage-well inflow are inorganic chemicals, organic compounds, turbidity, and microbiological contaminants. Potential contami- nant sources include plant nurseries, citrus groves, parking lots, plating companies, auto- motive repair shops, and most commonly, lake- overflow water. Drainage wells provide a pathway for contaminants to enter the Upper Floridan aquifer and there is a potential for contaminants to move downward from the Upper Floridan to the Lower Floridan aquifer.

  15. 24 CFR 3280.610 - Drainage systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... diameter piping shall be required for water closets. (f) Wet-vented drainage system. Plumbing fixture traps... connected to the drainage system shall be installed with a water seal trap (§ 3280.606(a)). (2) The drainage... to which it is connected and shall be equipped with a water-tight cap or plug matching the drain...

  16. Randomised clinical trial of chest drainage systems.

    PubMed Central

    Graham, A N; Cosgrove, A P; Gibbons, J R; McGuigan, J A

    1992-01-01

    BACKGROUND: Problems in the management of thoracic trauma have stimulated the search for an alternative to underwater seals for drainage of the pleural cavity. A chest drainage bag incorporating a one way flutter valve has been compared with underwater seal drains in a randomised clinical trial. METHODS: During June-December 1989 119 patients undergoing elective thoracotomy were randomised to receive postoperative chest drainage by drainage bags (56 patients, 87 drains) or by underwater seal drains (63 patients, 98 drains). Daily drainage volumes, the requirement for pleural suction, mobility, and complications were recorded prospectively. RESULTS: There was no significant difference between the two groups in the mean volume drained, the requirements for pleural suction, or the occurrence of complications. Patients with drainage bags were fully mobile 23 hours (95% confidence interval 0-47 hours) earlier than the others. CONCLUSIONS: When used after elective thoracotomy drainage bags are safe and effective and permit earlier mobility than underwater seal drains. PMID:1496507

  17. Prospective, randomised, controlled trial comparing suture needle drainage and argon laser drainage of subretinal fluid.

    PubMed Central

    Aylward, G W; Orr, G; Schwartz, S D; Leaver, P K

    1995-01-01

    AIMS--This study was designed to compare suture needle drainage (SND) with argon laser drainage (ALD) of subretinal fluid. METHODS--A prospective, randomised, controlled, clinical trial was carried out on 93 patients undergoing external drainage of subretinal fluid during scleral buckling surgery for rhegmatogenous retinal detachment. The incidence of successful drainage, incidence of subretinal haemorrhage, incidence of retinal incarceration, and incidence of retinal perforation were determined. RESULTS--The success rate was 97.9% in the ALD group and 84.8% in the SND group (difference-13.1%, 95% CI-26.4% to 2.0%). The incidence of clinically significant subretinal haemorrhage was 4.3% in the ALD group compared with 28.3% in the SND group (difference 24.0%, 95% CI 7.6% to 40.4%). The incidence of incarceration was comparable in each group. There were no cases of retinal perforation. CONCLUSIONS--The use of ALD was associated with a higher rate of successful SRF drainage, and a lower incidence of clinically significant subretinal haemorrhage than SND. ALD is preferred when an endolaser is available. PMID:7547781

  18. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  19. Prognostic relevance of an epigenetic biomarker panel in sentinel lymph nodes from colon cancer patients.

    PubMed

    Lind, Guro E; Guriby, Marianne; Ahlquist, Terje; Hussain, Israr; Jeanmougin, Marine; Søreide, Kjetil; Kørner, Hartwig; Lothe, Ragnhild A; Nordgård, Oddmund

    2017-01-01

    Patients with early colorectal cancer (stages I-II) generally have a good prognosis, but a subgroup of 15-20% experiences relapse and eventually die of disease. Occult metastases have been suggested as a marker for increased risk of recurrence in patients with node-negative disease. Using a previously identified, highly accurate epigenetic biomarker panel for early detection of colorectal tumors, we aimed at evaluating the prognostic value of occult metastases in sentinel lymph nodes of colon cancer patients. The biomarker panel was analyzed by quantitative methylation-specific PCR in primary tumors and 783 sentinel lymph nodes from 201 patients. The panel status in sentinel lymph nodes showed a strong association with lymph node stage ( P  = 8.2E-17). Compared with routine lymph node diagnostics, the biomarker panel had a sensitivity of 79% (31/39). Interestingly, among 162 patients with negative lymph nodes from routine diagnostics, 13 (8%) were positive for the biomarker panel. Colon cancer patients with high sentinel lymph node methylation had an inferior prognosis (5-year overall survival P  = 3.0E-4; time to recurrence P  = 3.1E-4), although not significant. The same trend was observed in multivariate analyses ( P  = 1.4E-1 and P  = 6.7E-2, respectively). Occult sentinel lymph node metastases were not detected in early stage (I-II) colon cancer patients who experienced relapse. Colon cancer patients with high sentinel lymph node methylation of the analyzed epigenetic biomarker panel had an inferior prognosis, although not significant in multivariate analyses. Occult metastases in TNM stage II patients that experienced relapse were not detected.

  20. A comparison of sentinel lymph node biopsy to lymphadenectomy for endometrial cancer staging (FIRES trial): a multicentre, prospective, cohort study.

    PubMed

    Rossi, Emma C; Kowalski, Lynn D; Scalici, Jennifer; Cantrell, Leigh; Schuler, Kevin; Hanna, Rabbie K; Method, Michael; Ade, Melissa; Ivanova, Anastasia; Boggess, John F

    2017-03-01

    Sentinel-lymph-node mapping has been advocated as an alternative staging technique for endometrial cancer. The aim of this study was to measure the sensitivity and negative predictive value of sentinel-lymph-node mapping compared with the gold standard of complete lymphadenectomy in detecting metastatic disease for endometrial cancer. In the FIRES multicentre, prospective, cohort study patients with clinical stage 1 endometrial cancer of all histologies and grades undergoing robotic staging were eligible for study inclusion. Patients received a standardised cervical injection of indocyanine green and sentinel-lymph-node mapping followed by pelvic lymphadenectomy with or without para-aortic lymphadenectomy. 18 surgeons from ten centres (tertiary academic and community non-academic) in the USA participated in the trial. Negative sentinel lymph nodes (by haematoxylin and eosin staining on sections) were ultra-staged with immunohistochemistry for cytokeratin. The primary endpoint, sensitivity of the sentinel-lymph-node-based detection of metastatic disease, was defined as the proportion of patients with node-positive disease with successful sentinel-lymph-node mapping who had metastatic disease correctly identified in the sentinel lymph node. Patients who had mapping of at least one sentinel lymph node were included in the primary analysis (per protocol). All patients who received study intervention (injection of dye), regardless of mapping result, were included as part of the assessment of mapping and in the safety analysis in an intention-to-treat manner. The trial was registered with ClinicalTrials.gov, number NCT01673022 and is completed and closed. Between Aug 1, 2012, and Oct 20, 2015, 385 patients were enrolled. Sentinel-lymph-node mapping with complete pelvic lymphadenectomy was done in 340 patients and para-aortic lymphadenectomy was done in 196 (58%) of these patients. 293 (86%) patients had successful mapping of at least one sentinel lymph node. 41 (12

  1. Mapping Mediterranean seagrasses with Sentinel-2 imagery.

    PubMed

    Traganos, Dimosthenis; Reinartz, Peter

    2017-07-01

    Mediterranean seagrasses have been hailed for their numerous ecosystem services, yet they are undergoing a decline in their coverage. The major complication with resolving this tendency is the sparsity of data on their overall distribution. This study addresses the suitability of the recently launched Sentinel-2 satellite for mapping the distribution of Mediterranean seagrass meadows. A comprehensive methodology is presented which applies atmospheric and analytical water column corrections and compares the performance of three different supervised classifiers. Remote sensing of the Thermaikos Gulf, northwestern Aegean Sea (Greece, eastern Mediterranean Sea) reveals that the utilization of Support Vector Machines on water column corrected reflectances yields best accuracies. Two Mediterranean seagrasses, Posidonia oceanica and Cymodocea nodosa, cover a total submerged area of 1.48km 2 between depths of 1.4-16.5m. With its 10-m spatial resolution and 5-day revisit frequency, Sentinel-2 imagery can mitigate the Mediterranean seagrass distribution data gap and allow better management and conservation in the future in a retrospective, time- and cost-effective fashion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. A dual-modal magnetic nanoparticle probe for preoperative and intraoperative mapping of sentinel lymph nodes by magnetic resonance and near infrared fluorescence imaging

    PubMed Central

    Zhou, Zhengyang; Chen, Hongwei; Lipowska, Malgorzata; Wang, Liya; Yu, Qiqi; Yang, Xiaofeng; Tiwari, Diana; Yang, Lily; Mao, Hui

    2016-01-01

    The ability to reliably detect sentinel lymph nodes for sentinel lymph node biopsy and lymphadenectomy is important in clinical management of patients with metastatic cancers. However, the traditional sentinel lymph node mapping with visible dyes is limited by the penetration depth of light and fast clearance of the dyes. On the other hand, sentinel lymph node mapping with radionucleotide technique has intrinsically low spatial resolution and does not provide anatomic details in the sentinel lymph node mapping procedure. This work reports the development of a dual modality imaging probe with magnetic resonance and near infrared imaging capabilities for sentinel lymph node mapping using magnetic iron oxide nanoparticles (10 nm core size) conjugated with a near infrared molecule with emission at 830 nm. Accumulation of magnetic iron oxide nanoparticles in sentinel lymph nodes leads to strong T2 weighted magnetic resonance imaging contrast that can be potentially used for preoperative localization of sentinel lymph nodes, while conjugated near infrared molecules provide optical imaging tracking of lymph nodes with a high signal to background ratio. The new magnetic nanoparticle based dual imaging probe exhibits a significant longer lymph node retention time. Near infrared signals from nanoparticle conjugated near infrared dyes last up to 60 min in sentinel lymph node compared to that of 25 min for the free near infrared dyes in a mouse model. Furthermore, axillary lymph nodes, in addition to sentinel lymph nodes, can be also visualized with this probe, given its slow clearance and sufficient sensitivity. Therefore, this new dual modality imaging probe with the tissue penetration and sensitive detection of sentinel lymph nodes can be applied for preoperative survey of lymph nodes with magnetic resonance imaging and allows intraoperative sentinel lymph node mapping using near infrared optical devices. PMID:23812946

  3. A critical assessment on the role of sentinel node mapping in endometrial cancer.

    PubMed

    Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Signorelli, Mauro; Perotto, Stefania; Lorusso, Domenica; Raspagliesi, Francesco

    2015-10-01

    Endometrial cancer is the most common gynecologic malignancy in the developed countries. Although the high incidence of this occurrence no consensus, about the role of retroperitoneal staging, still exists. Growing evidence support the safety and efficacy of sentinel lymph node mapping. This technique is emerging as a new standard for endometrial cancer staging procedures. In the present paper, we discuss the role of sentinel lymph node mapping in endometrial cancer, highlighting the most controversies features.

  4. Advances in drainage: Selected works from the Tenth International Drainage Symposium

    USGS Publications Warehouse

    Strock, Jeffrey S.; Hay, Christopher; Helmers, Matthew; Nelson, Kelly A.; Sands, Gary R.; Skaggs, R. Wayne; Douglas-Mankin, Kyle R.

    2018-01-01

    This article introduces a special collection of fourteen articles accepted from among the 140 technical presentations, posters, and meeting papers presented at the 10th International ASABE Drainage Symposium. The symposium continued in the tradition of previous symposia that began in 1965 as a forum for presenting and assessing the progress of drainage research and implementation throughout the world. The articles in this collection address a wide range of topics grouped into five broad categories: (1) crop response, (2) design and management, (3) hydrology and scale, (4) modeling, and (5) water quality. The collection provides valuable information for scientists, engineers, planners, and others working on crop production, water quality, and water quantity issues affected by agricultural drainage. The collection also provides perspectives on the challenges of increasing agricultural production in a changing climate, with ever-greater attention to water quality and quantity concerns that will require integrated technical, economic, and social solutions.

  5. The impact of superficial injections of radiocolloids and dynamic lymphoscintigraphy on sentinel node identification in oral cavity cancer: a same-day protocol.

    PubMed

    Tartaglione, Girolamo; Vigili, Maurizio G; Rahimi, Siavash; Celebrini, Alessandra; Pagan, Marco; Lauro, Luigi; Al-Nahhas, Adil; Rubello, Domenico

    2008-04-01

    To evaluate the role of dynamic lymphoscintigraphy with a same-day protocol for sentinel node biopsy in oral cavity cancer. Twenty-two consecutive patients affected by cT1-2N0 squamous cell carcinoma of the oral cavity were enrolled between September 2001 and November 2005. After a local anaesthetic (10% lidocaine spray), a dose of 30-50 MBq of Tc human serum albumin nanocolloid, in ml saline, was injected superficially (1-2 mm subendothelial injection) into four points around the lesion. Dynamic lymphoscintigraphy was acquired immediately (256x256 matrix, 5 min pre-set time, LEGP collimator) in lateral and anterior projections. The imaging was prolonged until the lymph nodes of at least two neck levels were visualized (time required min). About 3 h later (same-day protocol) the patients had a radioguided sentinel node biopsy. Elective neck dissection was performed in the first 13 patients; whereas the last nine patients had elective neck dissection only if the sentinel node was positive. Sentinel nodes were dissected into 1 mm thick block sections and studied by haematoxylin & eosin staining and immunohistochemistry (anticytokeratin antibody). The sentinel nodes were found on the 1st neck level in 13 cases, on the 2nd neck level in eight cases, and on the 3rd neck level in one case (100% sensitivity). The average number of sentinel nodes was 2.2 for each patient. The sentinel node was positive in eight patients (36%); with six of them having the sentinel node as the exclusive site of metastasis. No skip metastases were found in the 14 patients with negative sentinel node (100% specificity). Our preliminary data indicate that superficial injections of radiocolloid and dynamic lymphoscintigraphy provide a high success rate in sentinel node identification in oral cavity cancers. Dynamic lymphoscintigraphy helps in distinguishing sentinel node from second-tier lymph nodes. The same-day protocol is advisable in order to correctly identify the first sentinel node

  6. [Ascites drainage at home].

    PubMed

    Lutjeboer, Jacob; van Erkel, Arian R; van der Hoeven, J J M Koos; van der Meer, Rutger W

    2015-01-01

    Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled permanent ascites catheter is a good alternative for intermittent drainage. The patient can open - and then re-close - the catheter when abdominal pressure increases. We inserted 35 subcutaneously permanent ascites catheters in the course of the past 3.5 years in the Leiden University Medical Centre. The success rate was 100% and the complication risk was 2.9%. A subcutaneously tunnelled ascites catheter is an effective and safe palliative treatment for patients with end-stage malignant disease and suffering from ascites.

  7. Restoration of shallow peatlands on Exmoor (UK): initial effects on water quality

    NASA Astrophysics Data System (ADS)

    Grand-Clement, Emilie; Luscombe, David; Anderson, Karen; Gatis, Naomi; Ashe, Josie; Brazier, Richard

    2014-05-01

    Historical and recent anthropogenic pressure has had dramatic effects on peatlands throughout the UK. In the South West, drainage for agricultural reclamation and peat cutting since the 19th century has progressively altered the hydrological behaviour of the peatlands of Exmoor and Dartmoor National Parks. Lower water table levels have caused increased oxidation, erosion and vegetation change, further affecting the storage of carbon and the provision of other ecosystem services (i.e. supply of drinking water, biodiversity). Moreover, the location of these peatlands at the southernmost margin of the UK peatlands' geographical extent makes them extremely vulnerable to the predicted effects of climate change, i.e. increased temperature and change in rainfall pattern. An extensive programme of peatland restoration is currently underway on Exmoor. Drainage ditches were blocked to reinstate the hydrological behaviour, reduce the outflow of dissolved organic carbon and, in doing so, improve other ecosystem services delivered by peatlands. This paper will report on the water quality monitoring results from a small headwater catchment in Exmoor. We will show results comparing changes in Dissolved Organic Carbon (DOC) losses and colour pre- and post-restoration. Our experimental approach uses event-based water quality monitoring across three drainage ditches that are representative of the different scales of damage in the area. Samples were taken back to the laboratory and analysed for DOC and colour, using UV spectrophotometry and UV-vis spectrometry respectively. DOC loads were calculated using discharge for each drain. Overall, DOC concentrations ranged between 3 and 30mg/L. Both pre and post- restoration datasets presented high seasonal variability, with higher concentrations measured from June to September. No significant change in DOC concentrations was observed in the 6 months after restoration. It is hypothesised that the effects of restoration could be hidden by

  8. Novel Indocyanine Green-Phytate Colloid Technique for Sentinel Node Detection in Head and Neck: Mouse Study.

    PubMed

    Araki, Koji; Mizokami, Daisuke; Tomifuji, Masayuki; Yamashita, Taku; Ohnuki, Kazunobu; Umeda, Izumi O; Fujii, Hirofumi; Kosuda, Shigeru; Shiotani, Akihiro

    2014-08-01

    Sentinel node navigation surgery using real-time, near-infrared imaging with indocyanine green is becoming popular by allowing head and neck surgeons to avoid unnecessary neck dissection. The major drawback of this method is its quick migration through the lymphatics, limiting the diagnostic time window and undesirable detection of downstream nodes. We resolved this problem by mixing indocyanine green (ICG) with phytate colloid to retard its migration and demonstrated its feasibility in a nude mouse study. Experimental prospective animal study. Animal laboratory. Indocyanine green at 3 concentrations was tested to determine the optimal concentration for sentinel lymph node detection in a mouse model. Effect of indocyanine green with phytate colloid mixture solutions was also analyzed. Indocyanine green or mixture solution at different mixing ratios were injected into the tongue of nude mice and near-infrared fluorescence images were captured sequentially for up to 48 hours. The brightness of fluorescence in the sentinel lymph node and lymph nodes further downstream were assessed. Indocyanine green concentration >50 μg/mL did not improve sentinel lymph node detection. The addition of phytate colloid to indocyanine green extended the period when sentinel lymph node was detectable. Second echelon lymph nodes were not imaged in mice injected with the mixture, while these were visualized in mice injected with indocyanine green alone. This novel technique of ICG-phytate colloid mixture allows prolonged diagnostic time window, prevention of downstream subsequent nodes detection, and improved accuracy for the detection of true sentinel lymph nodes. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  9. Sentinel-3 SAR Altimetry Toolbox - Scientific Exploitation of Operational Missions (SEOM) Program Element

    NASA Astrophysics Data System (ADS)

    Benveniste, Jérôme; Lucas, Bruno; Dinardo, Salvatore

    2014-05-01

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage pioneered by ERS-1, ERS-2, Envisat and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the Sentinel-3 series is planned for launch in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission's data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d'Etudes Spatiales, the French Space Agency), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as net

  10. Sentinel-3 SAR Altimetry Toolbox - Scientific Exploitation of Operational Missions (SEOM) Program Element

    NASA Astrophysics Data System (ADS)

    Benveniste, Jérôme; Dinardo, Salvatore; Lucas, Bruno Manuel

    The prime objective of the SEOM (Scientific Exploitation of Operational Missions) element is to federate, support and expand the large international research community that the ERS, ENVISAT and the Envelope programmes have build up over the last 20 years for the future European operational Earth Observation missions, the Sentinels. Sentinel-3 builds directly on a proven heritage pioneered by ERS-1, ERS-2, Envisat and CryoSat-2, with a dual-frequency (Ku and C band) advanced Synthetic Aperture Radar Altimeter (SRAL) that provides measurements at a resolution of ~300m in SAR mode along track. Sentinel-3 will provide exact measurements of sea-surface height along with accurate topography measurements over sea ice, ice sheets, rivers and lakes. The first of the Sentinel-3 series is planned for launch in early 2015. The current universal altimetry toolbox is BRAT (Basic Radar Altimetry Toolbox) which can read all previous and current altimetry mission’s data, but it does not have the capabilities to read the upcoming Sentinel-3 L1 and L2 products. ESA will endeavour to develop and supply this capability to support the users of the future Sentinel-3 SAR Altimetry Mission. BRAT is a collection of tools and tutorial documents designed to facilitate the processing of radar altimetry data. This project started in 2005 from the joint efforts of ESA (European Space Agency) and CNES (Centre National d’Etudes Spatiales, the French Space Agency), and it is freely available at http://earth.esa.int/brat. The tools enable users to interact with the most common altimetry data formats, the BratGUI is the front-end for the powerful command line tools that are part of the BRAT suite. BRAT can also be used in conjunction with Matlab/IDL (via reading routines) or in C/C++/Fortran via a programming API, allowing the user to obtain desired data, bypassing the data-formatting hassle. BRAT can be used simply to visualise data quickly, or to translate the data into other formats such as

  11. Pre-operative biliary drainage for obstructive jaundice

    PubMed Central

    Fang, Yuan; Gurusamy, Kurinchi Selvan; Wang, Qin; Davidson, Brian R; Lin, He; Xie, Xiaodong; Wang, Chaohua

    2014-01-01

    Background Patients with obstructive jaundice have various pathophysiological changes that affect the liver, kidney, heart, and the immune system. There is considerable controversy as to whether temporary relief of biliary obstruction prior to major definitive surgery (pre-operative biliary drainage) is of any benefit to the patient. Objectives To assess the benefits and harms of pre-operative biliary drainage versus no pre-operative biliary drainage (direct surgery) in patients with obstructive jaundice (irrespective of a benign or malignant cause). Search methods We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, Cochrane Central Register of Controlled Clinical Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until February 2012. Selection criteria We included all randomised clinical trials comparing biliary drainage followed by surgery versus direct surgery, performed for obstructive jaundice, irrespective of the sample size, language, and publication status. Data collection and analysis Two authors independently assessed trials for inclusion and extracted data. We calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence intervals (CI) based on the available patient analyses. We assessed the risk of bias (systematic overestimation of benefit or systematic underestimation of harm) with components of the Cochrane risk of bias tool. We assessed the risk of play of chance (random errors) with trial sequential analysis. Main results We included six trials with 520 patients comparing pre-operative biliary drainage (265 patients) versus no pre-operative biliary drainage (255 patients). Four trials used percutaneous transhepatic biliary drainage and two trials used endoscopic sphincterotomy and stenting as the method of pre-operative biliary drainage. The risk of bias was high in all trials. The proportion of patients with malignant obstruction varied between 60

  12. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial.

    PubMed

    Wiggers, Jimme K; Coelen, Robert J S; Rauws, Erik A J; van Delden, Otto M; van Eijck, Casper H J; de Jonge, Jeroen; Porte, Robert J; Buis, Carlijn I; Dejong, Cornelis H C; Molenaar, I Quintus; Besselink, Marc G H; Busch, Olivier R C; Dijkgraaf, Marcel G W; van Gulik, Thomas M

    2015-02-14

    Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when severe drainage-related complications deteriorate the patients' condition or increase the risk of postoperative morbidity. Biliary drainage can cause cholangitis/cholecystitis, pancreatitis, hemorrhage, portal vein thrombosis, bowel wall perforation, or dehydration. Two methods of preoperative biliary drainage are mostly applied: endoscopic biliary drainage, which is currently used in most regional centers before referring patients for surgical treatment, and percutaneous transhepatic biliary drainage. Both methods are associated with severe drainage-related complications, but two small retrospective series found a lower incidence in the number of preoperative complications after percutaneous drainage compared to endoscopic drainage (18-25% versus 38-60%, respectively). The present study randomizes patients with potentially resectable PHC and biliary obstruction between preoperative endoscopic or percutaneous transhepatic biliary drainage. The study is a multi-center trial with an "all-comers" design, randomizing patients between endoscopic or percutaneous transhepatic biliary drainage. All patients selected to potentially undergo a major liver resection for presumed PHC are eligible for inclusion in the study provided that the biliary system in the future liver remnant is obstructed (even if they underwent previous inadequate endoscopic drainage). Primary outcome measure is the total number of severe preoperative complications between randomization and exploratory laparotomy. The study is designed to detect superiority of percutaneous drainage: a provisional sample size of 106 patients is required to detect a relative decrease of 50% in the number of severe preoperative

  13. Sentinel-1A - Launching the first satellite and launching the operational Copernicus programme

    NASA Astrophysics Data System (ADS)

    Aschbacher, Josef; Milagro Perez, Maria Pilar

    2014-05-01

    The first Copernicus satellite, Sentinel-1A, is prepared for launch in April 2014. It will provide continuous, systematic and highly reliable radar images of the Earth. Sentinel-1B will follow around 18 months later to increase observation frequency and establish an operational system. Sentinel-1 is designed to work in a pre-programmed conflict-free operation mode ensuring the reliability required by operational services and creating a consistent long-term data archive for applications based on long time series. This mission will ensure the continuation and improvement of SAR operational services and applications addressing primarily medium- to high-resolution applications through a main mode of operation that features both a wide swath (250 km) and high geometric (5 × 20 m) and radiometric resolution, allowing imaging of global landmasses, coastal zones, sea ice, polar areas, and shipping routes at high resolution. The Sentinel-1 main operational mode (Interferometric Wide Swath) will allow to have a complete coverage of the Earth in 6 days in the operational configuration when the two Sentinel-1 spacecraft will be in orbit simultaneously. High priority areas like Europe, Canada and some shipping routes will be covered almost daily. This high global observation frequency is unprecedented and cannot be reached with any other current radar mission. Envisat, for example, which was the 'workhorse' in this domain up to April 2012, reached global coverage every 35 days. Sentinel-1 data products will be made available systematically and free of charge to all users including institutional users, the general public, scientific and commercial users. The transition of the Copernicus programme from the development to operational phase will take place at about the same time when the first Sentinel-1 satellite will be launched. During the operational phase, funding of the programme will come from the European Union Multiannual Financial Framework (MFF) for the years 2014

  14. Cerebrospinal fluid drainage for syringomyelia.

    PubMed

    Williams, B; Sgouros, S; Nenji, E

    1995-12-01

    Twenty-eight years of experience with syringomyelia of various causes in the syringomyelia clinic at the Midland Centre for Neurosurgery and Neurology has provided a database of 723 patients, mostly adults, with either hindbrain herniation, syringomyelia or both. Treatment of syringomyelia by drainage has never been the optimum primary treatment on the basis that the cavity is usually secondary to some other disturbance of the cerebrospinal fluid pathways. Over this period 73 patients had either syrinx drainage (56 syringopleural, 14 syringo-subarachnoid shunts) or other procedure such as myelotomy and cord transection. Ten years after operation only 53.5% and 50% of these two groups respectively continued to remain clinically stable. A complication rate of 15.7% included fatal haemorrhage, infection and displacement of drains. At second operation or necropsy at least 5% of shunts were found to be blocked. All the shunts were inserted without a valve and the lowering of the intrasyrinx pressure has therefore been energetic when the lower end of the drainage tube has been taken to the pleural or peritoneal cavities. This produced collapse of the cord cavities around the tip of the drainage tube and increased the likelihood of blockage. If the mechanisms which were responsible for the syringomyelia were still operative then recurrence was likely to occur alongside the drainage tube leaving the tube immured in the wall of the syrinx cavity. When hydrocephalus was present, in addition treatment of the hydrocephalus by a valved shunt to the peritoneum or to the right atrium was often effective in improving the syringomyelia. This treatment has also been used in patients without hydrocephalus. The mechanisms of improvement were unclear but this treatment stratagem has nevertheless been employed in 45 cases. In 30 out of these 45 cases the drainage of cerebrospinal fluid from outside the syrinx cavities seemed to be worthwhile; 10 patients suffered some form of

  15. Knowing what we breathe: Sentinel 4: a geostationary imaging UVN spectrometer for air quality monitoring

    NASA Astrophysics Data System (ADS)

    Bazalgette Courrèges-Lacoste, G.; Sallusti, M.; Bulsa, G.; Bagnasco, G.; Gulde, S.; Kolm, M. G.; Smith, D. J.; Maurer, R.

    2017-09-01

    Sentinel-4 is an imaging UVN (UV-VIS-NIR) spectrometer, developed by Airbus DS under ESA contract in the frame of the joint EU/ESA COPERNICUS program. The mission objective is the operational monitoring of trace gas concentrations for atmospheric chemistry and climate applications - hence the motto of Sentinel-4 "Knowing what we breathe".

  16. Potential of Sentinel Satellites for Schistosomiasis Monitoring

    NASA Astrophysics Data System (ADS)

    Li, C.-R.; Tang, L.-L.; Niu, H.-B.; Zhou, X.-N.; Liu, Z.-Y.; Ma, L.-L.; Zhou, Y.-S.

    2012-04-01

    densities is developed. The new model is validated with field data of Dongting Lake and the dynamic monitoring of schistosomiasis breeding in Dongting Lake region is presented. Finally, emphasis are placed on analyzing the potential of Sentinel satellites for schistosomiasis monitoring. The requirements of optical high resolution data on spectral resolution, spatial resolution, radiometric resolution/accuracy, as well as the requirements of synthetic aperture radar data on operation frequency, spatial resolution, polarization, radiometric accuracy, repeat cycle are presented and then compared with the parameters of Sentinel satellites. The parameters of Sentinel satellites are also compared with those of available remote satellites, such as Envisat, Landsat, whose data are being used for schistosomiasis monitoring. The application potential of Sentinel satellites for the schistosomiasis monitoring will be concluded in the end, which will benefit for the mission operation, model development, etc.

  17. Sentinel node mapping for gastric cancer: a prospective multicenter trial in Japan.

    PubMed

    Kitagawa, Yuko; Takeuchi, Hiroya; Takagi, Yu; Natsugoe, Shoji; Terashima, Masanori; Murakami, Nozomu; Fujimura, Takashi; Tsujimoto, Hironori; Hayashi, Hideki; Yoshimizu, Nobunari; Takagane, Akinori; Mohri, Yasuhiko; Nabeshima, Kazuhito; Uenosono, Yoshikazu; Kinami, Shinichi; Sakamoto, Junichi; Morita, Satoshi; Aikou, Takashi; Miwa, Koichi; Kitajima, Masaki

    2013-10-10

    Complicated gastric lymphatic drainage potentially undermines the utility of sentinel node (SN) biopsy in patients with gastric cancer. Encouraged by several favorable single-institution reports, we conducted a multicenter, single-arm, phase II study of SN mapping that used a standardized dual tracer endoscopic injection technique. Patients with previously untreated cT1 or cT2 gastric adenocarcinomas < 4 cm in gross diameter were eligible for inclusion in this study. SN mapping was performed by using a standardized dual tracer endoscopic injection technique. Following biopsy of the identified SNs, mandatory comprehensive D2 or modified D2 gastrectomy was performed according to current Japanese Gastric Cancer Association guidelines. Among 433 patients who gave preoperative consent, 397 were deemed eligible on the basis of surgical findings. SN biopsy was performed in all patients, and the SN detection rate was 97.5% (387 of 397). Of 57 patients with lymph node metastasis by conventional hematoxylin and eosin staining, 93% (53 of 57) had positive SNs, and the accuracy of nodal evaluation for metastasis was 99% (383 of 387). Only four false-negative SN biopsies were observed, and pathologic analysis revealed that three of those biopsies were pT2 or tumors > 4 cm. We observed no serious adverse effects related to endoscopic tracer injection or the SN mapping procedure. The endoscopic dual tracer method for SN biopsy was confirmed as safe and effective when applied to the superficial, relatively small gastric adenocarcinomas included in this study.

  18. Use of sentinel lymph node biopsy to select patients for local–regional therapy after neoadjuvant chemotherapy

    PubMed Central

    Erdahl, Lillian M.; Boughey, Judy C.

    2014-01-01

    Use of sentinel lymph node biopsy for axillary staging of patients with breast cancer treated with neoadjuvant chemotherapy has been widely debated. Questions arise regarding the accuracy of sentinel lymph node biopsy in axillary staging for these patients and its use to determine further local–regional therapy, including surgery and radiation therapy. For patients who are clinically node-negative at presentation, sentinel lymph node biopsy enables accurate staging of the axilla after neoadjuvant chemotherapy, and determination of which patients should go on to further axillary surgery and regional nodal radiation therapy. Importantly, performing axillary staging after completion of chemotherapy, rather than before chemotherapy, enables assessment of response to chemotherapy and the extent of residual disease. This information can assist the planning of adjuvant treatment. Recent data indicate that sentinel node biopsy can also be used to assess disease response after neoadjuvant chemotherapy for patients with clinical N1 disease at presentation. PMID:24683440

  19. Extreme warming challenges sentinel status of kelp forests as indicators of climate change.

    PubMed

    Reed, Daniel; Washburn, Libe; Rassweiler, Andrew; Miller, Robert; Bell, Tom; Harrer, Shannon

    2016-12-13

    The desire to use sentinel species as early warning indicators of impending climate change effects on entire ecosystems is attractive, but we need to verify that such approaches have sound biological foundations. A recent large-scale warming event in the North Pacific Ocean of unprecedented magnitude and duration allowed us to evaluate the sentinel status of giant kelp, a coastal foundation species that thrives in cold, nutrient-rich waters and is considered sensitive to warming. Here, we show that giant kelp and the majority of species that associate with it did not presage ecosystem effects of extreme warming off southern California despite giant kelp's expected vulnerability. Our results challenge the general perception that kelp-dominated systems are highly vulnerable to extreme warming events and expose the more general risk of relying on supposed sentinel species that are assumed to be very sensitive to climate change.

  20. Extreme warming challenges sentinel status of kelp forests as indicators of climate change

    NASA Astrophysics Data System (ADS)

    Reed, Daniel; Washburn, Libe; Rassweiler, Andrew; Miller, Robert; Bell, Tom; Harrer, Shannon

    2016-12-01

    The desire to use sentinel species as early warning indicators of impending climate change effects on entire ecosystems is attractive, but we need to verify that such approaches have sound biological foundations. A recent large-scale warming event in the North Pacific Ocean of unprecedented magnitude and duration allowed us to evaluate the sentinel status of giant kelp, a coastal foundation species that thrives in cold, nutrient-rich waters and is considered sensitive to warming. Here, we show that giant kelp and the majority of species that associate with it did not presage ecosystem effects of extreme warming off southern California despite giant kelp's expected vulnerability. Our results challenge the general perception that kelp-dominated systems are highly vulnerable to extreme warming events and expose the more general risk of relying on supposed sentinel species that are assumed to be very sensitive to climate change.

  1. Sentinel-2A image quality commissioning phase final results: geometric calibration and performances

    NASA Astrophysics Data System (ADS)

    Languille, F.; Gaudel, A.; Dechoz, C.; Greslou, D.; de Lussy, F.; Trémas, T.; Poulain, V.; Massera, S.

    2016-10-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 offers multispectral high-spatial-resolution optical images over global terrestrial surfaces. In cooperation with ESA, the Centre National d'Etudes Spatiales (CNES) is in charge of the image quality of the project, and so ensures the CAL/VAL commissioning phase during the months following the launch. Sentinel-2 is a constellation of 2 satellites on a polar sun-synchronous orbit with a revisit time of 5 days (with both satellites), a high field of view - 290km, 13 spectral bands in visible and shortwave infrared, and high spatial resolution - 10m, 20m and 60m. The Sentinel-2 mission offers a global coverage over terrestrial surfaces. The satellites acquire systematically terrestrial surfaces under the same viewing conditions in order to have temporal images stacks. The first satellite was launched in June 2015. Following the launch, the CAL/VAL commissioning phase is then lasting during 6 months for geometrical calibration. This paper will point on observations and results seen on Sentinel-2 images during commissioning phase. It will provide explanations about Sentinel-2 products delivered with geometric corrections. This paper will detail calibration sites, and the methods used for geometrical parameters calibration and will present linked results. The following topics will be presented: viewing frames orientation assessment, focal plane mapping for all spectral bands, results on geolocation assessment, and multispectral registration. There is a systematic images recalibration over a same reference which is a set of S2 images produced during the 6 months of CAL/VAL. This set of images will be presented as well as the geolocation performance and the multitemporal performance after refining over this ground reference.

  2. Analysing trends and forecasting malaria epidemics in Madagascar using a sentinel surveillance network: a web-based application.

    PubMed

    Girond, Florian; Randrianasolo, Laurence; Randriamampionona, Lea; Rakotomanana, Fanjasoa; Randrianarivelojosia, Milijaona; Ratsitorahina, Maherisoa; Brou, Télesphore Yao; Herbreteau, Vincent; Mangeas, Morgan; Zigiumugabe, Sixte; Hedje, Judith; Rogier, Christophe; Piola, Patrice

    2017-02-13

    The use of a malaria early warning system (MEWS) to trigger prompt public health interventions is a key step in adding value to the epidemiological data routinely collected by sentinel surveillance systems. This study describes a system using various epidemic thresholds and a forecasting component with the support of new technologies to improve the performance of a sentinel MEWS. Malaria-related data from 21 sentinel sites collected by Short Message Service are automatically analysed to detect malaria trends and malaria outbreak alerts with automated feedback reports. Roll Back Malaria partners can, through a user-friendly web-based tool, visualize potential outbreaks and generate a forecasting model. The system already demonstrated its ability to detect malaria outbreaks in Madagascar in 2014. This approach aims to maximize the usefulness of a sentinel surveillance system to predict and detect epidemics in limited-resource environments.

  3. Histologic pattern of Merkel cell carcinoma sentinel lymph node metastasis improves stratification of Stage III patients

    PubMed Central

    Ko, Jennifer S; Prieto, Victor G; Elson, Paul; Vilain, Ricardo E; Pulitzer, Melissa; Scolyer, Richard A; Reynolds, Jordan P; Piliang, Melissa; Ernstoff, Marc S; Gastman, Brian; Billings, Steven D

    2016-01-01

    Sentinel lymph node biopsy is used to stage Merkel cell carcinoma, but its prognostic value has been questioned. Furthermore, predictors of outcome in sentinel lymph node positive Merkel cell carcinoma patients are poorly defined. In breast carcinoma, isolated immunohistochemically positive tumor cells have no impact, but in melanoma they are considered significant. The significance of sentinel lymph node metastasis tumor burden (including isolated tumor cells) and pattern of involvement in Merkel cell carcinoma are unknown. In this study, 64 Merkel cell carcinomas involving sentinel lymph nodes and corresponding immunohistochemical stains were reviewed and clinicopathologic predictors of outcome were sought. Five metastatic patterns were identified: 1, sheet-like (n=38, 59%); 2, non-solid parafollicular (n=4, 6%); 3, sinusoidal, (n=11, 17%); 4, perivascular hilar (n=1, 2%) and 5, rare scattered parenchymal cells (n=10, 16%). At the time of follow-up, 30/63 (48%) patients had died with 21(33%) attributable to Merkel cell carcinoma. Patients with pattern 1 metastases had poorer overall survival compared with patients with patterns 2–5 metastases (p=0.03), with 22/30 (73%) deaths occurring in pattern 1 patients. 3 (10%) deaths occurred in patients showing pattern 5, all of whom were immunosuppressed. 4 (13%) deaths occurred in pattern 3 patients and 1 (3%) death occurred in a pattern 2 patient. In multivariable analysis, the number of positive sentinel lymph node (1 or 2 versus >2, p<.0001), age (<70 versus ≥70, p=.01), sentinel lymph node metastasis pattern (patterns 2–5 versus 1, p=.02), and immune status (immunocompetent versus suppressed, p=.03) were independent predictors of outcome, and could be used to stratify Stage III patients into 3 groups with markedly different outcomes. In Merkel cell carcinoma, the pattern of sentinel lymph node involvement provides important prognostic information and utilizing this data with other clinicopathologic features

  4. Histological pattern of Merkel cell carcinoma sentinel lymph node metastasis improves stratification of Stage III patients.

    PubMed

    Ko, Jennifer S; Prieto, Victor G; Elson, Paul J; Vilain, Ricardo E; Pulitzer, Melissa P; Scolyer, Richard A; Reynolds, Jordan P; Piliang, Melissa P; Ernstoff, Marc S; Gastman, Brian R; Billings, Steven D

    2016-02-01

    Sentinel lymph node biopsy is used to stage Merkel cell carcinoma, but its prognostic value has been questioned. Furthermore, predictors of outcome in sentinel lymph node positive Merkel cell carcinoma patients are poorly defined. In breast carcinoma, isolated immunohistochemically positive tumor cells have no impact, but in melanoma they are considered significant. The significance of sentinel lymph node metastasis tumor burden (including isolated tumor cells) and pattern of involvement in Merkel cell carcinoma are unknown. In this study, 64 Merkel cell carcinomas involving sentinel lymph nodes and corresponding immunohistochemical stains were reviewed and clinicopathological predictors of outcome were sought. Five metastatic patterns were identified: (1) sheet-like (n=38, 59%); (2) non-solid parafollicular (n=4, 6%); (3) sinusoidal, (n=11, 17%); (4) perivascular hilar (n=1, 2%); and (5) rare scattered parenchymal cells (n=10, 16%). At the time of follow-up, 30/63 (48%) patients had died with 21 (33%) attributable to Merkel cell carcinoma. Patients with pattern 1 metastases had poorer overall survival compared with patients with patterns 2-5 metastases (P=0.03), with 22/30 (73%) deaths occurring in pattern 1 patients. Three (10%) deaths occurred in patients showing pattern 5, all of whom were immunosuppressed. Four (13%) deaths occurred in pattern 3 patients and 1 (3%) death occurred in a pattern 2 patient. In multivariable analysis, the number of positive sentinel lymph nodes (1 or 2 versus >2, P<0.0001), age (<70 versus ≥70, P=0.01), sentinel lymph node metastasis pattern (patterns 2-5 versus 1, P=0.02), and immune status (immunocompetent versus suppressed, P=0.03) were independent predictors of outcome, and could be used to stratify Stage III patients into three groups with markedly different outcomes. In Merkel cell carcinoma, the pattern of sentinel lymph node involvement provides important prognostic information and utilizing this data with other

  5. [Application of digital 3D technique combined with nanocarbon-aided navigation in endoscopic sentinel lymph node biopsy for breast cancer].

    PubMed

    Zhang, Pu-Sheng; Luo, Yun-Feng; Yu, Jin-Long; Fang, Chi-Hua; Shi, Fu-Jun; Deng, Jian-Wen

    2016-08-20

    To study the clinical value of digital 3D technique combined with nanocarbon-aided navigation in endoscopic sentinel lymph node biopsy for breast cancer. Thirty-nine female patients with stage I/II breast cancer admitted in our hospital between September 2014 and September 2015 were recruited. CT lymphography data of the patients were segmented to reconstruct digital 3D models, which were imported into FreeForm Modeling Surgical System Platform for visual simulation surgery before operation. Endoscopic sentinel lymph node biopsy and endoscopic axillary lymph node dissection were then carried out, and the accuracy and clinical value of digital 3D technique in endoscopic sentinel lymph node biopsy were analyzed. s The 3D models faithfully represented the surgical anatomy of the patients and clearly displayed the 3D relationship among the sentinel lymph nodes, axillary lymph nodes, axillary vein, pectoralis major, pectoralis minor muscle and latissimus dorsi. In the biopsy, the detection rate of sentinel lymph nodes was 100% in the patients with a coincidence rate of 87.18% (34/39), a sensitivity of 91.67% (11/12), and a false negative rate of 8.33% (1/12). Complications such as limb pain, swelling, wound infection, and subcutaneouseroma were not found in these patients 6 months after the operation. Endoscopic sentinel lymph node biopsy assisted by digital 3D technique and nanocarbon-aided navigation allows a high detection rate of sentinel lymph nodes with a high sensitivity and a low false negative rate and can serve as a new method for sentinel lymph node biopsy for breast cancer.

  6. Comparison of Medpor coated tear drainage tube versus silicon tear drainage tube in conjunctivodacryocystorhinostomy: problems and solutions.

    PubMed

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction.

  7. Comparison of Medpor Coated Tear Drainage Tube versus Silicon Tear Drainage Tube in Conjunctivodacryocystorhinostomy: Problems and Solutions

    PubMed Central

    Sendul, Selam Yekta; Cagatay, Halil Huseyin; Dirim, Burcu; Demir, Mehmet; Yıldız, Ali Atakhan; Acar, Zeynep; Cinar, Sonmez; Guven, Dilek

    2014-01-01

    Purpose. This study aims at comparing two different types of drainage tubes in conjunctivodacryocystorhinostomy, which are used for upper lacrimal system obstruction or damage, with respect to their respective postoperative problems and solutions. Methods. Nineteen eyes of 17 patients who underwent conjunctivodacryocystorhinostomy (CDCR) or conjunctivorhinostomy (CR) surgery with a Medpor coated tear drainage tube or silicon tube placement between October, 2010, and February, 2014, were included in this retrospective comparative study. Results. In the initial surgery, Medpor coated tear drainage tubes were used in 11 eyes by CDCR, whereas silicon tear drainage tubes were implanted into 2 eyes by CR and 6 eyes by CDCR. In group 1, proximal and distal obstructions developed postoperatively in 4 eyes, while 1 eye showed tube malposition and 3 eyes developed luminal obstruction by debris 3 times. In group 2, tube extrusion developed in 4 eyes, whereas tube malposition developed in 6 eyes and luminal obstruction by debris developed in 6 eyes at different times, for a total of 20 times. Conclusions. In our study, the most significant complication we observed in the use of silicon tear drainage tubes was tube extrusion,whereas the leading complication related to the use of Medpor coated tear drainage tubes was tube obstruction. PMID:25379518

  8. Drainage in Shallow Peatlands of Marginal Upland Landscapes: DOC Losses from High Flow Events

    NASA Astrophysics Data System (ADS)

    Grand-Clement, E.; Anderson, K.; Luscombe, D.; Gatis, N.; Benaud, P.; Brazier, R.

    2013-12-01

    Peatlands are widely represented in northern Europe, especially in the UK. In the South West of England (i.e. Exmoor, Dartmoor and Bodmin moors), climate change puts their existence under threat: according to recent modelling work, marginal peatlands are highly vulnerable to future temperature and precipitation change and are likely to be the first to disappear from as early as 2050. Additionally, peat cutting and intensive drainage for agricultural reclamation in the 19th and 20th century, have modified the hydrological behaviour of these shallow peatlands and dried out the upper layers, causing oxidation, erosion and vegetation change. Such anthropogenic interventions directly impact on the storage of carbon, but also the provision of other ecosystem services, such as the supply of drinking water, and the support of specific and rare habitats. Large restoration programs involving the blocking of drainage ditches are currently under way throughout the UK but, to date, little is known about the consequences of such management approaches on overall Carbon stocks, and whether the restoration can revert ecosystems back to a state similar to that of undisturbed peatlands. In this context, Exmoor is particularly vulnerable due to its location at the southernmost margin of the UK peatlands' geographical extent, and its dense network of drainage ditches putting pressure on already very shallow peat resources. We hypothesise that monitoring of these peatlands may provide an ';early warning system' for climatic impacts that could affect more northerly sites in years to come, as climates change more significantly. The aim of this study is to look at the current impact of peatland degradation on water quality on Exmoor during rainfall-runoff events. Our experimental approach employs detailed, high resolution monitoring of selected ditches that are representative of damaged conditions on Exmoor, from small- (30 x 30cm ditches) through medium- (50x50cm), large- (1-2m ditches

  9. Evaluating the capabilities of vegetation spectral indices on chlorophyll content estimation at Sentinel-2 spectral resolutions

    NASA Astrophysics Data System (ADS)

    Sun, Qi; Jiao, Quanjun; Dai, Huayang

    2018-03-01

    Chlorophyll is an important pigment in green plants for photosynthesis and obtaining the energy for growth and development. The rapid, nondestructive and accurate estimation of chlorophyll content is significant for understanding the crops growth, monitoring the disease and insect, and assessing the yield of crops. Sentinel-2 equipped with the Multi-Spectral Instrument (MSI), which will provide images with high spatial, spectral and temporal resolution. It covers the VNIR/SWIR spectral region in 13 bands and incorporates two new spectral bands in the red-edge region and a spatial resolution of 20nm, which can be used to derive vegetation indices using red-edge bands. In this paper, we will focus on assessing the potential of vegetation spectral indices for retrieving chlorophyll content from Sentinel-2 at different angles. Subsequently, we used in-situ spectral data and Sentinel-2 data to test the relationship between VIs and chlorophyll content. The REP, MTCI, CIred-edge, CIgreen, Macc01, TCARI/OSAVI [705,750], NDRE1 and NDRE2 were calculated. NDRE2 index displays a strongly similar result for hyperspectral and simulated Sentinel-2 spectral bands (R2 =0.53, R2 =0.51, for hyperspectral and Sentinel-2, respectively). At different observation angles, NDRE2 has the smallest difference in performance (R2 = 0.51, R2 =0.64, at 0° and 15° , respectively).

  10. Potential of the Sentinel-2 Red Edge Spectral Bands for Estimation of Eco-Physiological Plant Parameters

    NASA Astrophysics Data System (ADS)

    Malenovsky, Zbynek; Homolova, Lucie; Janoutova, Ruzena; Landier, Lucas; Gastellu-Etchegorry, Jean-Philippe; Berthelot, Beatrice; Huck, Alexis

    2016-08-01

    In this study we investigated importance of the space- borne instrument Sentinel-2 red edge spectral bands and reconstructed red edge position (REP) for retrieval of the three eco-physiological plant parameters, leaf and canopy chlorophyll content and leaf area index (LAI), in case of maize agricultural fields and beech and spruce forest stands. Sentinel-2 spectral bands and REP of the investigated vegetation canopies were simulated in the Discrete Anisotropic Radiative Transfer (DART) model. Their potential for estimation of the plant parameters was assessed through training support vector regressions (SVR) and examining their P-vector matrices indicating significance of each input. The trained SVR were then applied on Sentinel-2 simulated images and the acquired estimates were cross-compared with results from high spatial resolution airborne retrievals. Results showed that contribution of REP was significant for canopy chlorophyll content, but less significant for leaf chlorophyll content and insignificant for leaf area index estimations. However, the red edge spectral bands contributed strongly to the retrievals of all parameters, especially canopy and leaf chlorophyll content. Application of SVR on Sentinel-2 simulated images demonstrated, in general, an overestimation of leaf chlorophyll content and an underestimation of LAI when compared to the reciprocal airborne estimates. In the follow-up investigation, we will apply the trained SVR algorithms on real Sentinel-2 multispectral images acquired during vegetation seasons 2015 and 2016.

  11. Is peritoneal drainage essential after pancreatic surgery?

    PubMed Central

    Huan, Lu; Fei, Qilin; Lin, Huapeng; Wan, Lun; Li, Yue

    2017-01-01

    Abstract Aim: Our objective is to assess the function of peritoneal drainage, which is placed after pancreatic surgery. Background: With the medical advancement some study put forward that peritoneal drainage is not the necessary after pancreatic surgery; it cannot improve the complications of postoperation even leading to more infection and so on. However, there is no one study can clear and definite whether omitting the drainage after surgery or not. Method: Searching databases consist of all kinds of searching tools, such as Medline, The Cochrane Library, Embase, PubMed, etc. All the included studies should meet our demand of this meta-analysis. In the all interest outcomes blow we take the full advantage of RevMan5 to assess, the main measure is odds ratio (OR) with 95% confidence, the publication bias are assessed by Egger test and Begg test. Result: The rate of postoperative pancreatic fistula (POPF) in no drainage group is much lower than that in routine drainage group (OR = 0.47, I2 = 43%, P < .00001). The result of the 2 randomized controlled trials (RCTs) in this pool are almost accord with the former (OR = 0.57, I2 = 0%, P = .05). In subgroup the result suggest that the peritoneal drainage can increase the morbidity (OR = 0.71, I2 = 15%, P = .0002) after pancreaticoduodenectomy (PD), but reduce the mortality (OR = 1.92, I2 = 8%, P = .03) after PD. In distal pancreatectomy (DP) the rate of POPF and clinically relevant pancreatic fistula (CR-PF) is lower without drainage; there is no significant difference in the CR-PF, hospital stay, intra-abdominal abscess, radiologic invention, and the reoperation. Conclusion: In the current meta-analysis, we cannot make a clear conclusion whether to abandon the routine drainage or not, but from the subgroup we can see something is safer than nothing to routine peritoneal drainage. And the patients who underwent DP can attempt to omit the drainage. But it still needs more

  12. Simple model of foam drainage

    NASA Astrophysics Data System (ADS)

    Fortes, M. A.; Coughlan, S.

    1994-10-01

    A simple model of foam drainage is introduced in which the Plateau borders and quadruple junctions are identified with pools that discharge through channels to pools underneath. The flow is driven by gravity and there are friction losses in the exhausting channels. The equation of Bernoulli combined with the Hagen-Poiseuille equation is applied to describe the flow. The area of the cross section of the exhausting channels can be taken as a constant or may vary during drainage. The predictions of the model are compared with standard drainage curves and with the results of a recently reported experiment in which additional liquid is supplied at the top of the froth.

  13. Over-wintering of Supraglacial Lakes on the Greenland Ice Sheet from Sentinel-1 and Landsat-8 Data

    NASA Astrophysics Data System (ADS)

    Benedek, C. L.; Tedesco, M.

    2015-12-01

    Supra-glacial lakes on the GrIS have become a focus of research relating to the contribution of the GrIS to sea level rise. Lakes have been observed to appear during the summer melt season. Though it appears that the quantity of water collected on the surface is small, it is thought that the fracture and drainage of these lakes delivers significant pulses of water to the ice sheet bed, influencing the dynamic movement of glaciers towards the sea. The pattern of this transport mechanism may be a central driver of its influence over dynamic losses, as the flow of the viscoelastic ice sheet will differ if the water is delivered in a short pulse or a slower constant supply. A number of studies have catalogued the traits of lakes with an aim to quantify lake areas, depths, and timing of formation and cessation using visible and near infrared remote sensing instruments mostly focused on the summer melt season. Little is known about the behaviour of the surface lakes over the winter. A recent examination of the over-wintering of surface lakes has been conducted by Koenig et al. [2015] using airborne radar. While the study is extensive in area covered, it is limited in its temporal resolution by the availability of Operation IceBridge data, typically at one pass per year. This study seeks to observe the development of lakes over the winter period. Sentinel-1A radar images are used to track the presence of surface lakes and their variation in three study sites on the Greenland ice sheet. The sites are as follows: upstream of Ryder glacier, upstream of Petermann glacier, and upstream of Jakobshavn glacier. Water masks are created based on summer Landsat-8 images following NDWIice and then compared to Sentinel images at monthly temporal resolution through the winter of 2014-2015. These radar images show persistence of liquid water through the winter in agreement with previous research as well as variation in the buried lake area over the span of the year studied.

  14. SENTINEL-2 Global Reference Image Validation and Application to Multitemporal Performances and High Latitude Digital Surface Model

    NASA Astrophysics Data System (ADS)

    Gaudel, A.; Languille, F.; Delvit, J. M.; Michel, J.; Cournet, M.; Poulain, V.; Youssefi, D.

    2017-05-01

    In the frame of the Copernicus program of the European Commission, Sentinel-2 is a constellation of 2 satellites with a revisit time of 5 days in order to have temporal images stacks and a global coverage over terrestrial surfaces. Satellite 2A was launched in June 2015, and satellite 2B will be launched in March 2017. In cooperation with the European Space Agency (ESA), the French space agency (CNES) is in charge of the image quality of the project, and so ensures the CAL/VAL commissioning phase during the months following the launch. This cooperation is also extended to routine phase as CNES supports European Space Research Institute (ESRIN) and the Sentinel-2 Mission performance Centre (MPC) for validation in geometric and radiometric image quality aspects, and in Sentinel-2 GRI geolocation performance assessment whose results will be presented in this paper. The GRI is a set of S2A images at 10m resolution covering the whole world with a good and consistent geolocation. This ground reference enables accurate multi-temporal registration of refined Sentinel-2 products. While not primarily intended for the generation of DSM, Sentinel-2 swaths overlap between orbits would also allow for the generation of a complete DSM of land and ices over 60° of northern latitudes (expected accuracy: few S2 pixels in altimetry). This DSM would benefit from the very frequent revisit times of Sentinel-2, to monitor ice or snow level in area of frequent changes, or to increase measurement accuracy in areas of little changes.

  15. Outcomes of Heimlich valve drainage in dogs.

    PubMed

    Salci, H; Bayram, A S; Gorgul, O S

    2009-04-01

    Retrospective study of the outcomes of Heimlich valve drainage in dogs. Medical records of the past 3 years were retrospectively reviewed. Heimlich valve drainage was used in 34 dogs (median body weight 30 +/- 5 kg): lobectomy (n = 15), pneumonectomy (n = 9), intrathoracic oesophageal surgery (n = 2), diaphragmatic hernia repair (n = 1), traumatic open pneumothorax (n = 2), bilobectomy (n = 2), ligation of the thoracic duct (n = 1), and chylothorax and pneumothorax (n = 1 each). Evacuation of air and/or fluid from the pleural cavity was performed with the Heimlich valve following thoracostomy tube insertion. During drainage, the dogs were closely monitored for possible respiratory failure. Termination of Heimlich valve drainage was controlled with underwater seal drainage and assessed with thoracic radiography. Negative intrathoracic pressure was provided in 29 dogs without any complications. Post pneumonectomy respiratory syncope and post lobectomy massive hemothorax, which did not originate from the Heimlich valve, were the only postoperative complications. Dysfunction of the valve diaphragm, open pneumothorax and intrathoracic localisation of an acute gastric dilatation-volvulus syndrome caused by a left-sided diaphragmatic hernia following pneumonectomy were the Heimlich valve drainage complications. The Heimlich valve can be used as a continuous drainage device in dogs, but the complications reported here should be considered by veterinary practitioners.

  16. Geohydrologic reconnaissance of drainage wells in Florida

    USGS Publications Warehouse

    Kimrey, J.O.; Fayard, L.D.

    1984-01-01

    Drainage wells are used to inject surface waters directly into an aquifer, or shallow ground waters directly into a deeper aquifer, primarily by gravity. Such wells in Florida may be grouped into two broad types: (1) surface-water injection wells, and (2) interaquifer connector wells. Drainage wells of the first type are further categorized as either Floridan aquifer drainage wells or Biscayne aquifer drainage wells. Floridan aquifer drainage wells are commonly used to supplement drainage for urban areas in karst terranes of central and north Florida. Data are available for 25 wells in the Ocala, Live Oak, and Orlando areas that allow comparison of the quality of water samples from these Floridan aquifer drainage wells with allowable contaminant levels. Comparison indicates that maximum contaminant levels for turbidity, color, and iron, manganese, and lead concentrations are equaled or exceeded in some drainage-well samples, and relatively high counts for coliform bacteria are present in most wells. Biscayne aquifer drainage wells are used locally to dispose of stormwater runoff and other surplus water in southeast Florida, where large numbers of these wells have been permitted in Dade and Broward Counties. The majority of these wells are used to dispose of water from swimming pools or to dispose of heated water from air-conditioning units. The use of Biscayne aquifer drainage wells may have minimal effect on aquifer potability so long as injection of runoff and industrial wates is restricted to zones where chloride concentrations exceed 1,500 milligrams per liter. Interaquifer connector wells are used in the phosphate mining areas of Polk and Hillsborough Counties, to drain mines and recharge the Floridan aquifer. Water-quality data available from 13 connector wells indicate that samples from most of these wells exceed standards values for iron concentration and turbidity. One well yielded a highly mineralized water, and samples from 6 of the other 12 wells exceed

  17. Sentinel Node Biopsy for the Head and Neck Using Contrast-Enhanced Ultrasonography Combined with Indocyanine Green Fluorescence in Animal Models: A Feasibility Study.

    PubMed

    Kogashiwa, Yasunao; Sakurai, Hiroyuki; Akimoto, Yoshihiro; Sato, Dai; Ikeda, Tetsuya; Matsumoto, Yoshifumi; Moro, Yorihisa; Kimura, Toru; Hamanoue, Yasuhiro; Nakamura, Takehiro; Yamauchi, Koichi; Saito, Koichiro; Sugasawa, Masashi; Kohno, Naoyuki

    2015-01-01

    Sentinel node navigation surgery is gaining popularity in oral cancer. We assessed application of sentinel lymph node navigation surgery to pharyngeal and laryngeal cancers by evaluating the combination of contrast-enhanced ultrasonography and indocyanine green fluorescence in animal models. This was a prospective, nonrandomized, experimental study in rabbit and swine animal models. A mixture of indocyanine green and Sonazoid was used as the tracer. The tracer mixture was injected into the tongue, larynx, or pharynx. The sentinel lymph nodes were identified transcutaneously by infra-red camera and contrast-enhanced ultrasonography. Detection time and extraction time of the sentinel lymph nodes were measured. The safety of the tracer mixture in terms of mucosal reaction was evaluated macroscopically and microscopically. Sentinel lymph nodes were detected transcutaneously by contrast-enhanced ultrasonography alone. The number of sentinel lymph nodes detected was one or two. Despite observation of contrast enhancement of Sonazoid for at least 90 minutes, the number of sentinel lymph nodes detected did not change. The average extraction time of sentinel lymph nodes was 4.8 minutes. Indocyanine green fluorescence offered visual information during lymph node biopsy. The safety of the tracer was confirmed by absence of laryngeal edema both macro and microscopically. The combination method of indocyanine green fluorescence and contrast-enhanced ultrasonography for detecting sentinel lymph nodes during surgery for head and neck cancer seems promising, especially for pharyngeal and laryngeal cancer. Further clinical studies to confirm this are warranted.

  18. A critical review of variables affecting the accuracy and false-negative rate of sentinel node biopsy procedures in early breast cancer.

    PubMed

    Vijayakumar, Vani; Boerner, Philip S; Jani, Ashesh B; Vijayakumar, Srinivasan

    2005-05-01

    Radionuclide sentinel lymph node localization and biopsy is a staging procedure that is being increasingly used to evaluate patients with invasive breast cancer who have clinically normal axillary nodes. The most important prognostic indicator in patients with invasive breast cancer is the axillary node status, which must also be known for correct staging, and influences the selection of adjuvant therapies. The accuracy of sentinel lymph node localization depends on a number of factors, including the injection method, the operating surgeon's experience and the hospital setting. The efficacy of sentinel lymph node mapping can be determined by two measures: the sentinel lymph node identification rate and the false-negative rate. Of these, the false-negative rate is the most important, based on a review of 92 studies. As sentinel lymph node procedures vary widely, nuclear medicine physicians and radiologists must be acquainted with the advantages and disadvantages of the various techniques. In this review, the factors that influence the success of different techniques are examined, and studies which have investigated false-negative rates and/or sentinel lymph node identification rates are summarized.

  19. Sustainable Drainage, Green Infrastructure or Natural Flood Management - which should you choose?

    NASA Astrophysics Data System (ADS)

    Wingfield, Thea; Potter, Karen; Jones, Gareth; Spees, Jack; Macdonald, Neil

    2016-04-01

    River catchments as management units are more effective than administrative boundaries to integrate and coordinate efforts of organisations that utilise and manage water, soil and habitat quality. The UK government announced a pilot integrated water management initiative called, 'The Catchment Based Approach', on World Water Day 2011. After successful trials the scheme was extended to all river catchments in England during the summer of 2013. This policy has been designed to improve the collaboration, partnership and coordination of organisations involved in water and land management through locally led partnership groups. The lead organisations are all charitable bodies with significantly varying levels of experience of stormwater management; a key component of integrated water management and of great concern to communities at risk. These partnerships have implemented a number of Nature Based Solutions, but these have been presented in different ways by the different groups. In the UK there are three terms commonly used to describe Nature Based Solutions for managing the drainage of stormwater: Sustainable Drainage (SuDS), Green Infrastructure (GI) and Natural Flood Management (NFM). The definitions of each refers to the replication of natural hydrological processes in order to slow the flow of water through the landscape. But, there has been some concerns as to which of these nature based terms should be applied and why they appear to be used interchangeably. This study demonstrates that, despite the definitions of these three terms being almost identical, in practice they are not the same and should not be used interchangeably. The terms were developed by different professional groups in response to their own objectives and histories. The hydrological processes used to manage storm-water may be the same and the suggested interventions may show a degree of convergence. Yet, they operate at different scales, both geographically and organisationally. The different

  20. Postoperative drainage in head and neck surgery.

    PubMed

    Amir, Ida; Morar, Pradeep; Belloso, Antonio

    2010-11-01

    A major factor affecting patients' length of hospitalisation following head and neck surgery remains the use of surgical drains. The optimal time to remove these drains has not been well defined. A routine practice is to measure the drainage every 24 h and remove the drain when daily drainage falls below 25 ml. This study aims to determine whether drainage measurement at shorter intervals decreases the time to drain removal and hence the length of in-patient stays. A 6-month prospective observational study was performed. The inclusion criteria were patients who underwent head and neck surgery without neck dissection and had a closed suction drain inserted. Drainage rates were measured at 8-hourly intervals. Drains were removed when drainage-rate was ≤ 1 ml/h over an 8-h period. A total of 43 patients were evaluated. The highest drainage rate occurred in the first 8 postoperative hours and decreased significantly in the subsequent hours. The median drainage rates at 8, 16, 24, 32 and 40 postoperative hours were 3.375, 1, 0, 0 and 0 ml/h, respectively. Applying our new removal criteria of ≤ 1 ml/h drainage rate, the drains were removed in 22 (51%) patients at the 16th postoperative hour; 37 (86%) were removed by 24 h after operation. In comparison, only nine (20.9%) patients could potentially be discharged the day after surgery if previous criteria of ≤ 25 ml/24-h were used to decide on drain removal. Our 8-hourly drainage-rate monitoring has facilitated safe earlier discharge of an additional 28 (65%) patients on the day after surgery. This has led to improvement in patient care, better optimisation of hospital resources and resulted in positive economic implications to the department.

  1. Long term drainage alters plant biodiversity and soil C- and N-storage

    NASA Astrophysics Data System (ADS)

    Wolf, K.; Bol, R.; Dungait, J. A. J.; Dixon, L.; Dhanoa, D.; Beaumont, D.; Wiesenberg, G. L. B.

    2012-04-01

    Moisture and slope position can have a strong influence on soil properties and plant communities. In a long term permanent grassland experiment, sub-surface drainage was introduced in 1982 on some plots of Rowden Moor at North Wyke (SW UK). The soil is a Stagnic vertic Cambisol with a dense clay layer at shallow depth. After drainage the plant community had shifted from a Lolium perenne dominated grassland with patches of Juncus sp. towards a typical grassland plant community dominated by Lolium perenne and Trifolium sp. In addition, soil carbon and nitrogen concentrations significantly decreased. This is related to a smaller contribution of plant-derived organic matter to soil due to the change in plant community structure, and the enhanced mineralization of soil organic matter (SOM) under lower soil moisture. However, for C:N ratios neither plants nor soil did reveal any drainage related change arguing for an identical degradability of plant and soil organic matter. Furthermore the δ13C values tend to get more negative in soil, which could be related to the changing plant community. For δ15N no changes were observed, which was surprising as increase δ15N values were expected due to the increase in legumes on the drained plot. Changes in the chemical composition of SOM were also examined using compositional changes of soil n-alkanes. A shift in the alkane abundance occurs from the upper part of the slope (dominated by n-C31), to the bottom parts (n-C29 enriched). The carbon preference index and average chain length of alkanes correlated between undrained and drained plots and decreased down slope. Similarly, several alkane ratios like n-C27/n-C31 declined, due to the enhanced mineralization. Hence, the molecular pattern changed on the one hand due to changing contribution of plant derived organic matter and on the other hand because of changing preservation of organic matter in soil. The study showed that drainage has a long term effect on the plant community

  2. Lymphatic mapping and sentinel node biopsy in ovarian tumors: a study using intra-operative Tc-99m-Phytate and lymphoscintigraphy imaging.

    PubMed

    Hassanzadeh, Malihe; Hosseini Farahabadi, Elham; Yousefi, Zohreh; Kadkhodayan, Sima; Zarifmahmoudi, Leili; Sadeghi, Ramin

    2016-09-07

    Experience on sentinel node mapping in ovarian tumors is very limited. We evaluated the sentinel node concept in ovarian tumors using intra-operativeTc-99m-Phytate injection and lymphoscintigraphy imaging. Thirty-five patients with a pelvic mass due to an ovarian pathology were included in the study. The radiotracer was injected just after laparotomy and before removal of the tumor either beneath the normal cortex (10 patients) or in the utero-ovarian and suspensory ligaments of the ovary just beneath the peritoneum two injections of the radiotracer (25 patients). For malignant masses, the sentinel nodes were identified using a hand held gamma probe. Then standard pelvic and para-aortic lymphadenectomy was performed. In case of benign pathologies or borderline ovarian tumors on frozen section, lymphadenectomy was not performed. The morning after surgery, all patients were sent for lymphoscintigraphy imaging of the abdomen and pelvis. Sentinel node was identified only in 4 patients of the cortical injection group. At least one sentinel node could be identified in 21 patients of the sub-peritoneal group. Sentinel nodes were identified only in the para-aortic area in 21, pelvic/para-aortic areas in 2, and pelvic only area in 2 patients. Three patients had lymph node involvement and all had involved sentinel nodes (no false negative case). Sentinel node mapping using intra-operative injection of the radiotracer (in the utero-ovarian and suspensory ligaments of the ovary just beneath the peritoneum) is feasible in ovarian tumors. Technical aspects of this method should be explored in larger multicenter studies in the future.

  3. Traditional Foley drainage systems--do they drain the bladder?

    PubMed

    Garcia, Maurice M; Gulati, Shelly; Liepmann, Dorian; Stackhouse, G Bennett; Greene, Kirsten; Stoller, Marshall L

    2007-01-01

    Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

  4. Beyond the Briganti nomogram: Individualisation of lymphadenectomy using selective sentinel node biopsy during radical prostatectomy for prostate cancer.

    PubMed

    Monserrat-Monfort, J J; Martinez-Sarmiento, M; Vera-Donoso, C D; Vera-Pinto, V; Sopena-Novales, P; Bello-Arqués, P; Boronat-Tormo, F

    To validate the technique of selective sentinel node biopsy for diagnosing and staging intermediate to high-risk prostate cancer by comparing the technique with conventional extended lymphadenectomy (eLFD) in a prospective, longitudinal comparative study. We applied the technique to 45 patients. After an intraprostatic injection of 99m Tc-nanocolloid and preoperative single-photon emission computed tomography (SPECT/CT), we extracted the sentinel lymph nodes, guided by a portable Sentinella® gamma camera and a laparoscopic gamma-ray detection probe. The eLFD was completed to establish the negative predictive value of the technique. SPECT/CT showed radiotracer deposits outside the eLFD territory in 73% of the patients and the laparoscopic gamma probe in 60%. The mean number of active foci per patient was 4.3 in the SPECT/CT and 3.2 in the laparoscopic gamma probe. The mean number of extracted sentinel lymph nodes was 4.3 (0-14), with 26% outside the eLFD territory. The lymph nodes were metastatic in 10 patients (22%), 6/40 (15%) when the prostatectomy was the primary treatment. In all cases with metastatic lymph nodes, there was at least one positive sentinel node. Metastatic sentinel lymph nodes were found outside the eLFD territory in 3/10 patients (30%). The sensitivity was 100%, the specificity was 94.73%, the positive predictive value was 81.81%, and the negative predictive value was 100%. Selective sentinel node biopsy is superior to eLFD for diagnosing lymph node involvement and can avoid eLFD when metastatic sentinel lymph nodes are not found (85%), with the consequent functional advantages. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. The organizational structure and governing principles of the Food and Drug Administration's Mini-Sentinel pilot program.

    PubMed

    Forrow, Susan; Campion, Daniel M; Herrinton, Lisa J; Nair, Vinit P; Robb, Melissa A; Wilson, Marcus; Platt, Richard

    2012-01-01

    The US Food and Drug Administration's Mini-Sentinel pilot program is developing an organizational structure as well as principles and policies to govern its operations. These will inform the structure and function of the eventual Sentinel System. Mini-Sentinel is a collaboration that includes 25 participating institutions. We describe the program's current organizational structure and its major principles and policies. The organization includes a coordinating center with program leadership provided by a principal investigator; a planning board and subcommittees; an operations center; and data, methods, and protocol cores. Ad hoc workgroups are created as needed. A privacy panel advises about protection of individual health information. Principles and policies are intended to ensure that Mini-Sentinel conforms to the principles of fair information practices, protects the privacy of individual health information, maintains the security and integrity of data, assures the confidentiality of proprietary information, provides accurate and timely communications, prevents or manages conflicts of interest, and preserves respect for intellectual property rights. Copyright © 2012 John Wiley & Sons, Ltd.

  6. 77 FR 67767 - Revision to the South Coast Portion of the California State Implementation Plan, CPV Sentinel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-14

    ...'') portion of the California SIP. This source-specific SIP revision is known as the CPV Sentinel Energy... South Coast Portion of the California State Implementation Plan, CPV Sentinel Energy Project AB 1318... Environmental Protection Agency (EPA) is taking final action to approve a source-specific State Implementation...

  7. 76 FR 2294 - Revision to the South Coast Portion of the California State Implementation Plan, CPV Sentinel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-13

    ... precursors, sulfur oxides (SO X ), to the CPV Sentinel Energy Project. The District's SIP approved NSR... Management District shall transfer sulfur oxides and particulate emission credits from the CPV Sentinel... needed to issue permits to construct and to meet requirements for sulfur oxides and particulate matter...

  8. Use of C-band Sentinel-1 and L-band UAVSAR data for flood extent mapping during Hurricane Harvey

    NASA Astrophysics Data System (ADS)

    Lakshmi, V.; Kundu, S.; Torres, R.

    2017-12-01

    Hurricane Harvey was one of the most destructive storms that struck the Houston area in August 2017 causing loss of life and property. In this study, an estimation of flooding extent is done using two sets of microwave remote sensing data, Unmanned Aerial Vehicle Synthetic Aperture Radar (UAVSAR) and Sentinel-1. UAVSAR is an L-band SAR (Synthetic Aperture Radar) data which is an airborne repeat-pass interferometric observation system and has 16 km swath. Sentinel-1 is the C band microwave data developed by European Space Agency covering a large area (250 km). Data are analyzed to examine the flood extent over Houston during Harvey. Flood extent mapping is carried out using the Sentinel-1 data and UAVSAR using backscatter signatures which displays the extent of changes and destruction during the flood. Keywords: Harvey, UAVSAR, Sentinel-1, flood extent

  9. A comparative study of treatments for chronic subdural hematoma: burr hole drainage versus burr hole drainage with irrigation.

    PubMed

    Ishibashi, Akira; Yokokura, Yoshitake; Adachi, Hisashi

    2011-01-01

    Although chronic subdural hematoma (CSDH) is one of the most common entities encountered in neurosurgical practice, optimal surgical treatment for CSDH remains controversial. This study retrospectively compared results for CSDH between burr hole drainage alone and burr hole drainage with irrigation. Ninety-two patients with CSDH underwent surgery at our institution from January 1998 through December 2009. Fifty-eight patients received burr hole drainage alone (Group A), while 34 patients were treated using burr hole drainage with irrigation (Group B). Outcomes, recurrence rates, and death rates for the two groups were analyzed. Age, sex ratio, consciousness level on admission, radiodensity of hematoma on computed tomography before surgery, and duration of hospitalization were nearly the same in both groups. No significant differences were seen in good outcomes or death rates between groups, but poor outcomes were significantly more frequent in Group A (p=0.009). The recurrence rate was higher in Group A compared to Group B (10.3% vs. 2.9%). The authors used logistic regression analysis to identify factors associated with the outcome of CSDH, and found that duration of hospital stay, anti-coagulant therapy, presence of dementia and burr hole drainage alone were significantly associated with poor outcome of CSDH. These results indicate that burr hole drainage with irrigation has a significantly stronger association with good outcomes compared to drainage alone, and could be a reliable and effective operative method for the treatment of CSDH with a lower recurrence rate.

  10. Potential of future operational missions sentinel 4 and 5 for atmospheric monitoring and science (CAMELOT).

    NASA Astrophysics Data System (ADS)

    Levelt, P. F.; Veefkind, J. P.

    2010-05-01

    Dedicated atmospheric chemistry observations from space have been made for over 30 years now, starting with the SBUV and TOMS measurements of the ozone layer. Since then huge progress has been made, improving the accuracy of the measurements, extending the amount of constituents, and by sensing not only the stratosphere, but the last five to ten years also the troposphere. The potential to operational monitor the atmosphere, following the meteorological community, came within reach. At the same time, the importance for society of regular operational environmental measurements, related to the ozone layer, air quality and climate change, became apparent, amongst others resulting in the EU initiative Global Monitoring for Environment and Security (GMES) In order to prepare the operational missions in the context of the GMES, ESA took the initiative to further study the user requirements for the Sentinel 4 and 5 (precursor) missions. The Sentinel 4 and 5 (precursor) missions are dedicated operational missions to monitor the atmospheric composition in the 2013-2020 timeframe and onward. The user requirements for the sentinel missions focus on monitoring the atmosphere from an environmental point of view (ozone layer, air quality and climate). ESA's CAMELOT (Composition of the Atmospheric Mission concEpts and SentineL Observation Techniques) study is the follow-on study to ESA's CAPACITY study finished in 2005. The general objective of the CAMELOT study is to further contribute to the definition of the air quality and climate protocol monitoring parts of the GMES Sentinel 4 and 5 missions. CAMELOT consists of a large European consortium formed by 9 European institutes (KNMI (lead), RAL, U.Leicester, SRON, FMI, BIRA-IASB, CNR-IFAC,NOVELTIS and RIU-U.Koeln). In the presentation an overview will give a short overview of the CAMELOT study, including some specific results for combined retrievals, cloud statistics for different orbit geometries and retrievals for several orbit

  11. One-inch field of view imaging probe for breast cancer sentinel node location

    NASA Astrophysics Data System (ADS)

    D'Errico, Giovanni; Scafé, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University "La Sapienza" who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations—a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06″ SD 26″ with IP and 2', 18″ SD 47″ with neoprobe 2000. The most difficult to find node required 2 min and 56 s—inside sd—for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe.

  12. Potentiality of SENTINEL-1 for landslide detection: first results in the Molise Region (Italy)

    NASA Astrophysics Data System (ADS)

    Barra, Anna; Monserrat, Oriol; Mazzanti, Paolo; Esposito, Carlo; Crosetto, Michele; Scarascia Mugnozza, Gabriele

    2016-04-01

    A detailed inventory map, including information on landslide activity, is one of the most important input to landslide susceptibility and hazard analyses. The contribution of satellite SAR Interferometry in landslide risk mitigation is well-known within the scientific community. In fact, many encouraging results have been obtained, principally, in areas characterized by high coherence of the images (e.g. due to rock lithology or urban environment setting). In terms of coherence, the expected increased capabilities of Sentinel-1 for landslide mapping and monitoring are connected to both wavelength (55.5 mm) and short temporal baseline (12 days). The latter one is expected to be a key feature for increasing coherence and for defining monitoring and updating plans. With the aim of assessing these potentialities, we processed a set of 14 Sentinel-1 SLC images, acquired during a temporal span of 7 months, over the Molise region (Southern Italy), a critical area geologically susceptible to landslides. Even though Molise is mostly covered by crops and forested areas (63% and 35% respectively), that means a non-optimal coherence condition for SAR interferometry, promising results have been obtained. This has been achieved by integrating differential interferometric SAR techniques (12-days interferograms and time series) with GIS multilayer analysis (optical, geological, geomorphological, etc.). Specifically, analyzing a single burst of a Sentinel-1 frame (approximately 1875 km2), 62 landslides have been detected, thus allowing to improve the pre-existing inventory maps both in terms of landslide boundaries and state of activity. The results of our ongoing research show that Sentinel-1 can give a significant improvement in terms of exploitation of SAR data for landslide mapping and monitoring. As a matter of fact, by analyzing longer periods, it is expected to achieve a better understanding of landslide behavior and its relationship with triggering factors. This will be key

  13. Tectonic and volcanic monitoring using Sentinel-1: Current status and future plans of the COMET InSAR portal

    NASA Astrophysics Data System (ADS)

    Spaans, Karsten; Hatton, Emma; Gonzalez, Pablo; Walters, Richard; McDougall, Alistair; Wright, Tim; Hooper, Andy

    2017-04-01

    The advantages of the Sentinel-1 constellation for InSAR applications over previous radar missions are numerous, and include small baselines, a planned operation time of 20 years, continuous and systematic acquisition of data over tectonic and volcanic areas, near-global coverage of the earth and free data availability. In order to take advantage of these properties, we at the Centre for the Observation and Modelling of Earthquakes, Volcanoes, and Tectonics (COMET) are developing a system that routinely processes and freely distributes interferometric products and time series over tectonic and volcanic regions. This project, and similar efforts at other institutions, will be a game changer for the monitoring and studying of tectonic and volcanic activity using InSAR. Since December 2016, the COMET-LiCS InSAR portal (http://comet.nerc.ac.uk/COMET-LiCS-portal/) has been live, delivering interferograms and coherence estimates over the entire Alpine-Himalayan belt. The portal already contains tens of thousands of products, which can be browsed in a user-friendly portal, and downloaded for free by the general public. For our processing, we use the Climate and Environmental Monitoring from Space (CEMS) facility, where we have large storage and processing facilities to our disposal and a complete duplicate of the Sentinel-1 archive is maintained. This greatly simplifies the infrastructure we have had to develop for automated processing of large areas. Here we will give an overview of the current status of the processing system, as well as discuss future plans. We will cover the infrastructure we developed to automatically produce interferograms and its challenges, and the processing strategy for time series analysis. We will outline the objectives of the system in the near and distant future, and a roadmap for its continued development. Finally, we will highlight some of the scientific results and projects linked to the system.

  14. Fluorescence-guided mapping of sentinel lymph nodes in gynecological malignancies

    NASA Astrophysics Data System (ADS)

    Hirsch, Ole; Szyc, Łukasz; Muallem, Mustafa Zelal; Ignat, Iulia; Chekerov, Radoslav; Macdonald, Rainer; Sehouli, Jalid; Braicu, Ioana; Grosenick, Dirk

    2017-07-01

    We have successfully applied a custom-made handheld fluorescence camera for intraoperative fluorescence detection of indocyanine green in a feasibility study on sentinel lymph node mapping in patients with vulvar, cervical, endometrial and ovarian cancer.

  15. Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?

    PubMed

    Schaarschmidt, Benedikt Michael; Grueneisen, Johannes; Stebner, Vanessa; Klode, Joachim; Stoffels, Ingo; Umutlu, Lale; Schadendorf, Dirk; Heusch, Philipp; Antoch, Gerald; Pöppel, Thorsten Dirk

    2018-06-06

    To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true

  16. Capturing pre-failure signs of slope instability using multi-temporal interferometry and Sentinel-1 data

    NASA Astrophysics Data System (ADS)

    Wasowski, Janusz; Bovenga, Fabio; Nitti, Davide Oscar; Tijani, Khalid; Morea, Alberto; Nutricato, Raffaele; Chiaradia, Maria Teresa

    2017-04-01

    The shorter repeat cycle (6 days since October 2016) and regularity of acquisitions of Sentinel-1A/B with respect to earlier European Space Agency (ESA) satellites with C-band sensors (ERS1/2, ENVISAT) represent the key advantages for the research-oriented and practical applications of multi-temporal interferometry (MTI). The applicability of the Interferometric Wide Swath acquisition mode of Sentinel-1 (images covering a 250 km swath on the ground) to regional scale slope instability detection through MTI has already been demonstrated, e.g., via studies of landslide-prone areas in Italy. Here we focus on the potential of Sentinel-1 data for local (site-specific), MTI-based monitoring and capturing pre-failure signs of slope instability, by exploiting the Persistent and Distributed Scatterers processing capability of the SPINUA algorithm. In particular, we present an example of a retrospective study of a large (over 2 km long) landslide, which took place in 2016 in an active open-cast coal mine in central Europe. This seemingly sudden failure caused destruction of the mining equipment, blocked the mining operations thereby resulting in significant economic losses. For the study, we exploited over 60 Sentinel-1A/B images acquired since November 2014. The MTI results furnished a valuable overview of the ground instability/stability conditions within and around the active mine, even though considerable spatial gaps in information were encountered due to surface disturbance by mining operations. Significantly, the ground surface displacement time series revealed that the 2016 slope failure was preceded by very slow (generally 1-3 cm/yr) creep-like deformations, already present in 2014. The MTI results also indicated that the slope experienced a phase of accelerated movement several weeks prior to the landslide event. Furthermore, the spatio-temporal analysis of interferometric coherence changes in the unstable area (mapped on Sentinel-2 Bottom Of Atmosphere reflectance

  17. Characterization of asphalt drainage course layers.

    DOT National Transportation Integrated Search

    2010-08-01

    Asphalt Drainage Courses (ADCs) have generally been required under all four-lane flexible : pavements in Mississippi. Asphalt drainage courses are designed in Mississippi using No. 57 limestone, : sandstone or granite combined with 2.5 percent asphal...

  18. Co- and post-seismic deformation for the 2014 Napa Valley Earthquake from Sentinel-1A interferometry

    NASA Astrophysics Data System (ADS)

    Elliott, J. R.; Wright, T. J.; Elliott, A. J.; González, P. J.; Hooper, A. J.; Larsen, Y.; Marinkovic, P.; Plain, M.; Walters, R. J.

    2014-12-01

    Here we present analysis of co- and post-seismic deformation for the 24 August 2014 Napa Valley Earthquake derived from Sentinel-1A interferometry. We use these to derive the co-seismic slip distribution and map the evolution of post-seismic afterslip. The 24 August 2014 Napa Valley earthquake was the first earthquake for which surface deformation was measured by Sentinel-1A, a new radar satellite launched by the European Space Agency on 3 April 2014, and operated by the European Commission's Copernicus program. Sentinel-1A reached its final operational orbit on 7 August, and fortuitously acquired a pre-earthquake image of the San Francisco Bay area on that day in StripMap mode. By comparing it with an image acquired on 31 August, we formed a co-seismic interferogram, which reveals the surface deformation that occurred during the earthquake and the first 7 days of the post-seismic period. We use this to constrain a simple elastic model of the co-seismic slip distribution; preliminary inversion results show that the slip at depth reached a peak of >1.5 m at a depth of ~4 km. Following the earthquake, Sentinel-1A has acquired further acquisitions in both StripMap and Interferometric Wide Swath modes. The first 12-day post-seismic StripMap interferogram shows a sharp discontinuity along the entire fault rupture, consistent with field observations of rapid afterslip. We will use the full time series from August to December to measure the spatio-temporal behaviour of the afterslip, and discuss the implications for the frictional properties of the fault. The results from Napa point to an exciting and impactful future for the Sentinel-1 radar constellation. By mid-2014, Sentinel-1A will be acquiring data systematically over all the seismic belts, and the launch of Sentinel-1B in 2016 will increase the temporal frequency of acquisitions. The data will be available free of charge and will transform our ability to conduct tectonic geodesy, particularly in remote areas of the

  19. A portable thoracic closed drainage instrument for hemopneumothorax.

    PubMed

    Tang, Hua; Pan, Tiewen; Qin, Xiong; Xue, Lei; Wu, Bin; Zhao, Xuewei; Sun, Guangyuan; Yuan, Xinyu; Xu, Zhifei

    2012-03-01

    Hemopneumothorax is a common sequelae of traumatic thoracic injury. The most effective treatment of this condition is thoracic drainage. Despite the common occurrence of this condition, available instruments are difficult to use emergently, particularly when large amounts of patients need to be drained. In the present experiment, a newly designed chest tube and thoracic closed drainage package is described and preliminarily evaluated with the goal to improve the treatment of traumatic hemopneumothorax. Twenty canines were divided into two groups. In one group, the newly designed thoracic closed drainage package was used, whereas in the other group a currently available chest tube and bottle were used. Drainage test, ultrasound examination, flushing test, and tension test were performed to evaluate the effectiveness of the drainage package. We found that the newly-designed drainage tube is as effective as the common tube when evaluated using all of the chosen methods. In addition, the package is very lightweight and portable. The newly-designed thoracic drainage package is very effective in the emergency treatment of thoracic trauma and may be more suitable for the emergency treatment of hemopneumothorax.

  20. Lymphoscintigraphy Can Select Breast Cancer Patients for Internal Mammary Chain Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hindie, Elif, E-mail: elif.hindie@sls.aphp.fr; Department of Nuclear Medicine, CHU de Bordeaux, University of Bordeaux-Segalen, Bordeaux; Groheux, David

    2012-07-15

    Purpose: Given the risk of undesired toxicity, prophylactic internal mammary (IM) chain irradiation should be offered only to patients at high risk of occult involvement. Lymphoscintigraphy for axillary sentinel node biopsy might help in selecting these patients. Methods and Materials: We reviewed published studies with the following selection criteria: {>=}300 breast cancer patients referred for axilla sentinel node biopsy; scintigraphy performed after peritumoral or intratumoral tracer injection; IM biopsy in the case of IM drainage; and axilla staged routinely independent of IM status. Results: Six prospective studies, for a total of 3,876 patients, fulfilled the inclusion criteria. Parasternal drainage wasmore » present in 792 patients (20.4%). IM biopsy was performed in 644 patients and was positive in 111 (17.2%). Of the positive IM biopsies, 40% were associated with tumors in the lateral breast quadrants. A major difference in the IM positivity rate was found according to the axilla sentinel node status. In patients with negative axilla, the IM biopsy was positive in 7.8% of cases. In patients with positive axilla, however, the IM biopsy was positive in 41% (p < .00001). Because biopsy of multiple IM hot nodes is difficult, the true risk could be even greater, probably close to 50%. Conclusions: Patients with IM drainage on lymphoscintigraphy and a positive axilla sentinel node have a high risk of occult IM involvement. These women should be considered for IM radiotherapy.« less

  1. Murine norovirus detection in the exhaust air of IVCs is more sensitive than serological analysis of soiled bedding sentinels.

    PubMed

    Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus

    2017-06-01

    One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.

  2. 5. GLACIER POINT ROAD VIEW AT SENTINEL DOME PARKING AREA. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. GLACIER POINT ROAD VIEW AT SENTINEL DOME PARKING AREA. LOOKING E. GIS: N-37 42 43.8 / W-119 35 12.1 - Glacier Point Road, Between Chinquapin Flat & Glacier Point, Yosemite Village, Mariposa County, CA

  3. A 1 cm space debris impact onto the Sentinel-1A solar array

    NASA Astrophysics Data System (ADS)

    Krag, H.; Serrano, M.; Braun, V.; Kuchynka, P.; Catania, M.; Siminski, J.; Schimmerohn, M.; Marc, X.; Kuijper, D.; Shurmer, I.; O'Connell, A.; Otten, M.; Muñoz, Isidro; Morales, J.; Wermuth, M.; McKissock, D.

    2017-08-01

    Sentinel-1A is a 2-ton spacecraft of the Copernicus Earth observation program operated by ESA's Space Operations Centre in Darmstadt, Germany. Sentinel-1A and its sister spacecraft Sentinel-1B operate in a sun-synchronous orbit at about 700 km altitude. On 2016/08/23 17:07:37 UTC, Sentinel-1A suffered from an anomaly resulting in a sudden permanent partial power loss and significant impulsive orbit and attitude changes. A deeper investigation identified that an impulsive orbit change against flight direction of 0.7 mm/s, estimated at the time of the event, gave the best results in terms of GPS residuals. At the same time, a peak attitude off-pointing of 0.7° (around the spacecraft yaw axis) and peak attitude rate increase of 0.04°/s (around the same axis) were observed. The simultaneous occurrence of these anomalies, starting from a sudden attitude change and ending with a permanent partial power loss, made an MMOD (Micro-Meteoroid and Orbital Debris) impact onto a solar array a possible explanation for this event. While the spacecraft is able to continue its mission nominally, a detailed investigation involving ESA's Space Debris and Flight Dynamics experts was conducted. An MMOD impact as an explanation gained further credibility, due to the pictures of the solar array taken by the on-board camera displaying a significant damage area. On September 7th, JSpOC (US Joint Space Operations Centre) informed SDO on 8 tracked fragments that are considered to be released by Sentinel-1A after the impact. This paper addresses the analysis that was performed on the data characterising the attitude and orbit change, the on-board camera image, and the tracked fragments. The data helped to identify the linear momentum vector while a flux analysis helped to identify the origin of the impactor and allowed to understand its mass and size characteristics.

  4. Estimation and mapping of above-ground biomass of mangrove forests and their replacement land uses in the Philippines using Sentinel imagery

    NASA Astrophysics Data System (ADS)

    Castillo, Jose Alan A.; Apan, Armando A.; Maraseni, Tek N.; Salmo, Severino G.

    2017-12-01

    The recent launch of the Sentinel-1 (SAR) and Sentinel-2 (multispectral) missions offers a new opportunity for land-based biomass mapping and monitoring especially in the tropics where deforestation is highest. Yet, unlike in agriculture and inland land uses, the use of Sentinel imagery has not been evaluated for biomass retrieval in mangrove forest and the non-forest land uses that replaced mangroves. In this study, we evaluated the ability of Sentinel imagery for the retrieval and predictive mapping of above-ground biomass of mangroves and their replacement land uses. We used Sentinel SAR and multispectral imagery to develop biomass prediction models through the conventional linear regression and novel Machine Learning algorithms. We developed models each from SAR raw polarisation backscatter data, multispectral bands, vegetation indices, and canopy biophysical variables. The results show that the model based on biophysical variable Leaf Area Index (LAI) derived from Sentinel-2 was more accurate in predicting the overall above-ground biomass. In contrast, the model which utilised optical bands had the lowest accuracy. However, the SAR-based model was more accurate in predicting the biomass in the usually deficient to low vegetation cover non-forest replacement land uses such as abandoned aquaculture pond, cleared mangrove and abandoned salt pond. These models had 0.82-0.83 correlation/agreement of observed and predicted value, and root mean square error of 27.8-28.5 Mg ha-1. Among the Sentinel-2 multispectral bands, the red and red edge bands (bands 4, 5 and 7), combined with elevation data, were the best variable set combination for biomass prediction. The red edge-based Inverted Red-Edge Chlorophyll Index had the highest prediction accuracy among the vegetation indices. Overall, Sentinel-1 SAR and Sentinel-2 multispectral imagery can provide satisfactory results in the retrieval and predictive mapping of the above-ground biomass of mangroves and the replacement

  5. Bordetella pertussis infections in travelers: data from the GeoSentinel global network.

    PubMed

    Barbosa, Felipe; Barnett, Elizabeth D; Gautret, Philippe; Schlagenhauf, Patricia; van Genderen, Perry J J; Grobusch, Martin P; Connor, Bradley A; Hamer, Davidson H; Hochberg, Natasha S

    2017-05-01

    Pertussis is a highly contagious, vaccine-preventable respiratory infection that is endemic worldwide. There are limited data regarding the occurrence of pertussis in travelers. The objective of this study is to identify travel-related pertussis cases reported to the GeoSentinel Surveillance Network. This is a descriptive, retrospective analysis of GeoSentinel records from 25 travel/tropical medicine clinics in 16 countries. Frequencies of demographic and travel-related characteristics and symptoms of 74 cases of pertussis in travelers and new immigrants from 1999 to 2015 were analysed. There were 74 probable and confirmed cases of pertussis in the GeoSentinel database; median age was 44 years, and 38 (51%) patients were female. Tourism was the most common reason for travel (41; 55%). Country of exposure was determined in 66 cases with travelers returning from India and China constituting the highest number of cases (10 cases each; 15% each). Seventy of 74 (95%) patients had respiratory symptoms, while fatigue and fever were reported by 21 (28%) and 20 (27%), respectively. Immunization status against pertussis was unknown. Most cases were reported after 2005 (69; 93%). Our study describes 74 cases of pertussis acquired during travel and reported to the GeoSentinel Network. Pertussis should be considered in returned travelers who present with respiratory symptoms. Surveillance and detection of imported cases are important to prevent onward transmission in the community. The pre-travel consultation provides an opportunity to verify immunization status and provide routine vaccinations such as pertussis. © International Society of Travel Medicine, 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  6. 77 FR 6107 - CPV Sentinel, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-911-000] CPV Sentinel... 204 Authorization This is a supplemental notice in the above-referenced proceeding of CPV Sentinel...-8659. Dated: February 1, 2012. Kimberly D. Bose, Secretary. [FR Doc. 2012-2701 Filed 2-6-12; 8:45 am...

  7. 7. YOSEMITE VALLEY SHUTTLE BUS AT SENTINEL BRIDGE SHUTTLE BUS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. YOSEMITE VALLEY SHUTTLE BUS AT SENTINEL BRIDGE SHUTTLE BUS AND PARKING LOT AREA. LOOKING WNW. GIS: N-37 40 36.2 / W-119 44 45.0 - Yosemite National Park Roads & Bridges, Yosemite Village, Mariposa County, CA

  8. Establishing effective sentinels - Setting the baseline for shale gas

    NASA Astrophysics Data System (ADS)

    Ward, C.; Worrall, F.

    2017-12-01

    The UK has a nascent shale gas industry and, unlike the US we have the opportunity to establish structures both physical and regulatory to reassure the public that any impact of a developing shale gas will be .properly licensed, regulated, monitored and, if necessary, mitigated. To assess and indeed demonstrate an impact of any activity, let alone those of shale gas exploitation, it is necessary to show, within a reasonable level of certainty, that the industry has changed a environmental state over and above that which was true without the activity present. The need for demonstrating impact not only means that a baseline needs to be established but that the baseline needs to be robustly established within a statistical and probabilistic framework so that certainty of impact can be demonstrated. A number of technologies have been proposed for monitoring the water quality impacts of shale gas developments, however, to be an effective and robust sentinel of change the parameter should have several properties: it should be a lead indicator and not a lag indicator of change; it should have a high contrast with the normal or background activity; it should show a high specificity for the activity of concern and not be associated with other activities; and it should readily deployed in time and space. By far the greatest difference between the waters arising from a shale gas well pad and surface waters is nothing more than salinity or its associated determinds. The salinity of flowback water and deep formation water can be many times greater than seawater let alone greater than the salinity of most UK surface waters. Therefore, we have built a probabilistic model of the salinity of English surface waters. We have developed a generalised linear model of the existing salinity data available for English surface waters. Generalised linear modelling means that we can use all the existing data, the approach is entirely data driven; it does not require parameterisation; and can

  9. Technetium-99m-labeled rituximab for use as a specific tracer of sentinel lymph node biopsy: a translational research study.

    PubMed

    Wang, Xuejuan; Yang, Zhi; Lin, Baohe; Zhang, Yan; Zhai, Shizhen; Zhao, Qichao; Xie, Qing; Liu, Fei; Han, Xuedi; Li, Jinfeng; Ouyang, Tao

    2016-06-21

    We aimed to develop and translate a CD20-antigen-targeted radiopharmaceutical, Technetium-99 m-labeled (99mTc) rituximab, for sentinel lymph node (SLN) detection. 99mTc-rituximab was synthesized and tested for stability in human serum. The binding affinity to CD20 was evaluated in Raji cells by flow cytometric analysis. Biodistribution and sentinel node mapping were carried out in bal b/c mice. Eighty-five patients with breast cancer participated in this study. Dynamic sentinel lymphoscintigraphy was first assessed in 12 patients before planar lymphoscintigraphy was assessed in a larger cohort. All patients underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph node dissection. The cell-binding study showed that 99mTc-rituximab possessed compatible affinity to human CD20. In the mechanism study, 99mTc-labeled anti-mouse CD20 monoclonal antibodies could bind to mouse CD20 and accumulate in the SLN with 2.62±1.25 % of the percentage of injected activity, which could be blocked by excessive unlabeled antibody. Low uptake of non-sentinel nodes and fast clearance from the injection site were observed in the mice. Sentinel nodes were identified in 82 of 85 breast cancer patients (96.5%) by lymphoscintigraphy and SLNB. The sensitivity, specificity, and accuracy were 96.8% (30/31), 100% (51/51), and 98.8% (81/82), respectively. 99mTc-rituximab, specifically binding to CD20, met most of the requirements of an ideal sentinel mapping agent for use in clinical settings.

  10. Non-surgical biliary drainage - technique, indications and results.

    PubMed

    Riemann, J F; Lux, G; Rösch, W; Beickert-Sterba, A

    1981-07-01

    Nonsurgical biliary drainage offers a therapeutic alternative in the palliation of malignant obstructive jaundice. Two basic approaches are available. The percutaneous transhepatic method can be employed either for external drainage or for the placement of an internal endoprosthesis. In the case of the transduodenal, transpapillary approach, either a pigtail catheter can be placed, after prior papillotomy, or - with or without the need to split the papillar - a nasobiliary drainage tube can be introduced. Successful drainage was achieved in 67 patients. In the majority of cases, external drainage was performed as a palliative measure in inoperable carcinoma of the biliodigestive system. In addition, however, pre-operative temporary drainage was also carried out to reduce the risks of surgery in patients with severe obstructive jaundice. The complication rate was low. Apart from biliary peritonitis, cholangitis and minor bleeds were observed. The rate of failure for technical reasons was a relatively low 10%.

  11. Molecular markers to complement sentinel node status in predicting survival in patients with high-risk locally invasive melanoma.

    PubMed

    Rowe, Casey J; Tang, Fiona; Hughes, Maria Celia B; Rodero, Mathieu P; Malt, Maryrose; Lambie, Duncan; Barbour, Andrew; Hayward, Nicholas K; Smithers, B Mark; Green, Adele C; Khosrotehrani, Kiarash

    2016-08-01

    Sentinel lymph node status is a major prognostic marker in locally invasive cutaneous melanoma. However, this procedure is not always feasible, requires advanced logistics and carries rare but significant morbidity. Previous studies have linked markers of tumour biology to patient survival. In this study, we aimed to combine the predictive value of established biomarkers in addition to clinical parameters as indicators of survival in addition to or instead of sentinel node biopsy in a cohort of high-risk melanoma patients. Patients with locally invasive melanomas undergoing sentinel lymph node biopsy were ascertained and prospectively followed. Information on mortality was validated through the National Death Index. Immunohistochemistry was used to analyse proteins previously reported to be associated with melanoma survival, namely Ki67, p16 and CD163. Evaluation and multivariate analyses according to REMARK criteria were used to generate models to predict disease-free and melanoma-specific survival. A total of 189 patients with available archival material of their primary tumour were analysed. Our study sample was representative of the entire cohort (N = 559). Average Breslow thickness was 2.5 mm. Thirty-two (17%) patients in the study sample died from melanoma during the follow-up period. A prognostic score was developed and was strongly predictive of survival, independent of sentinel node status. The score allowed classification of risk of melanoma death in sentinel node-negative patients. Combining clinicopathological factors and established biomarkers allows prediction of outcome in locally invasive melanoma and might be implemented in addition to or in cases when sentinel node biopsy cannot be performed. © 2016 UICC.

  12. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Design and development of the Sentinel-2 Multi Spectral Instrument and satellite system

    NASA Astrophysics Data System (ADS)

    Chorvalli, Vincent; Cazaubiel, Vincent; Bursch, Stefan; Welsch, Mario; Sontag, Heinz; Martimort, Philippe; Del Bello, Umberto; Sy, Omar; Laberinti, Paolo; Spoto, François

    2010-10-01

    2A and Sentinel-2B satellites currently under development will ensure systematic global acquisition of all land and coastal waters in the visible and short-wave infrared spectral domain with a 5 day revisit time at the equator. The Multi Spectral Instrument is a push-broom imager providing imagery in 13 spectral channels with spatial resolutions ranging from 10 m to 60 m and a swath width of 290 Km, larger than SPOT and Landsat. The instrument features a full field of view calibration device, a silicon carbide Three Mirror Anastigmat telescope with mirror dimensions up to 600 mm, specific filter stripe assemblies, newly developed Si-CMOS and HgCDTe detectors and a low noise wavelet compression video electronics. The 1.4 Tbits/s raw image date rate is reduced down to 490 Mbits/s at the output of the instrument to cope with the overall system transmission capability. The Sentinel-2 program has entered in the CD phase in 2009. Launch of Sentinel-2A satellite is scheduled for 2013.

  14. Fire monitoring capability of the joint Landsat and Sentinel 2 constellation

    NASA Astrophysics Data System (ADS)

    Murphy, S.; Wright, R.

    2017-12-01

    Fires are a global hazard. Landsat and Sentinel 2 can monitor the Earth's surface every 2 - 4 days. This provides an important opportunity to complement the operational (lower resolution) fire monitoring systems. Landsat-class sensors can detect small fires that would be missed by MODIS-classed sensors. All large fires start out as small fires. We analyze fire patterns in California from 1984 to 2017 and compare the performance of Landsat-type and MODIS-type sensors. Had an operational Landsat-Sentinel 2 fire detection system been in place at the time of the Soberanes fire last year (i.e. August 2016), the cost of suppressing of this fire event (US $236 million) could potentially have been reduced by an order of magnitude.

  15. Thoracoscopic Surgery for Pneumothorax Following Outpatient Drainage Therapy.

    PubMed

    Sano, Atsushi; Yotsumoto, Takuma

    2017-10-20

    We investigated the outcomes of surgery for pneumothorax following outpatient drainage therapy. We reviewed the records of 34 patients who underwent operations following outpatient drainage therapy with the Thoracic Vent at our hospital between December 2012 and September 2016. Indications for outpatient drainage therapy were pneumothorax without circulatory or respiratory failure and pleural effusion. Indications for surgical treatment were persistent air leakage and patient preference for surgery to prevent or reduce the incidence of recurrent pneumothorax. Intraoperatively, 9 of 34 cases showed loose adhesions around the Thoracic Vent, all of which were dissected bluntly. The preoperative drainage duration ranged from 5 to 13 days in patients with adhesions and from 3 to 19 days in those without adhesions, indicating no significant difference. The duration of preoperative drainage did not affect the incidence of adhesions. The operative duration ranged from 30 to 96 minutes in patients with adhesions and from 31 to 139 minutes in those without adhesions, also indicating no significant difference. Outpatient drainage therapy with the Thoracic Vent was useful for spontaneous pneumothorax patients who underwent surgery, and drainage for less than 3 weeks did not affect intraoperative or postoperative outcomes.

  16. Intraoperative sentinel node identification in early stage cervical cancer using a combination of radiolabeled albumin injection and isosulfan blue dye injection.

    PubMed

    Martínez-Palones, José M; Gil-Moreno, Antonio; Pérez-Benavente, María A; Roca, Isabel; Xercavins, Jordi

    2004-03-01

    We investigated the feasibility of sentinel lymph node identification using radioisotopic lymphatic mapping with technetium-99m-labeled human serum albumin and isosulfan blue dye injection in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between September 2000 and October 2002, 25 patients with cervical cancer FIGO stage I (n=24) or stage II (n=1) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (technetium-99m colloid albumin injection around the tumor) and intraoperative lymphatic mapping with blue dye and a handheld or laparoscopic gamma probe. Complete pelvic or paraaortic lymphadenectomy was performed in all cases by open surgery or laparoscopic surgery. In 23 evaluable patients, a total of 51 sentinel lymph nodes were detected by lymphoscintigraphy (mean 2.21 nodes per patient). Intraoperatively, 61 sentinel lymph nodes were identified, with a mean of 2.52 nodes per patient by gamma probe and a mean of 1.94 nodes per patient after isosulfan blue injection. Forty percent of sentinel nodes were found in the interiliac region and 25% in the external iliac area. Microscopic nodal metastases (four nodes) were confirmed in 12% of cases. All these lymph nodes were previously detected as sentinel lymph nodes. The remaining 419 nodes after pelvic lymphadenectomy were histologically negative. Sentinel lymph node identification with technetium-99m-labeled nanocolloid combined with blue dye injection is feasible and showed a 100% negative predictive value, and potentially identified women in whom lymph node dissection can be avoided.

  17. Meta-Analysis of Drainage Versus No Drainage After Laparoscopic Cholecystectomy

    PubMed Central

    Lucarelli, Pierino; Di Filippo, Annalisa; De Angelis, Francesco; Stipa, Francesco; Spaziani, Erasmo

    2014-01-01

    Background and Objectives: Routine drainage after laparoscopic cholecystectomy is still controversial. This meta-analysis was performed to assess the role of drains in reducing complications in laparoscopic cholecystectomy. Methods: An electronic search of Medline, Science Citation Index Expanded, Scopus, and the Cochrane Library database from January 1990 to June 2013 was performed to identify randomized clinical trials that compare prophylactic drainage with no drainage in laparoscopic cholecystectomy. The odds ratio for qualitative variables and standardized mean difference for continuous variables were calculated. Results: Twelve randomized controlled trials were included in the meta-analysis, involving 1939 patients randomized to a drain (960) versus no drain (979). The morbidity rate was lower in the no drain group (odds ratio, 1.97; 95% confidence interval, 1.26 to 3.10; P = .003). The wound infection rate was lower in the no drain group (odds ratio, 2.35; 95% confidence interval, 1.22 to 4.51; P = .01). Abdominal pain 24 hours after surgery was less severe in the no drain group (standardized mean difference, 2.30; 95% confidence interval, 1.27 to 3.34; P < .0001). No significant difference was present with respect to the presence and quantity of subhepatic fluid collection, shoulder tip pain, parenteral ketorolac consumption, nausea, vomiting, and hospital stay. Conclusion: This study was unable to prove that drains were useful in reducing complications in laparoscopic cholecystectomy. PMID:25516708

  18. Tile Drainage Expansion Detection using Satellite Soil Moisture Dynamics

    NASA Astrophysics Data System (ADS)

    Jacobs, J. M.; Cho, E.; Jia, X.

    2017-12-01

    In the past two decades, tile drainage installation has accelerated throughout the Red River of the North Basin (RRB) in parts of western Minnesota, eastern North Dakota, and a small area of northeastern South Dakota, because the flat topography and low-permeability soils in this region necessitated the removal of excess water to improve crop production. Interestingly, streamflow in the Red River has markedly increased and six of 13 major floods during the past century have occurred since the late 1990s. It has been suggested that the increase in RRB flooding could be due to change in agricultural practices, including extensive tile drainage installation. Reliable information on existing and future tile drainage installation is greatly needed to capture the rapid extension of tile drainage systems and to locate tile drainage systems in the north central U.S. including the RRB region. However, there are few reliable data of tile drainage installation records, except tile drainage permit records in the Bois de Sioux watershed (a sub-basin in southern part of the RRB where permits are required for tile drainage installation). This study presents a tile drainage expansion detection method based on a physical principle that the soil-drying rate may increase with increasing tile drainage for a given area. In order to capture the rate of change in soil drying rate with time over entire RRB (101,500 km2), two satellite-based microwave soil moisture records from the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E) and AMSR2 were used during 2002 to 2016. In this study, a sub-watershed level (HUC10) potential tile drainage growth map was developed and the results show good agreement with tile drainage permit records of six sub-watersheds in the Bois de Sioux watershed. Future analyses will include improvement of the potential tile drainage map through additional information using optical- and thermal-based sensor products and evaluation of its

  19. Bundle of measures for external cerebral ventricular drainage-associated ventriculitis.

    PubMed

    Chatzi, Maria; Karvouniaris, Marios; Makris, Demosthenes; Tsimitrea, Eleni; Gatos, Charalampos; Tasiou, Anastasia; Mantzarlis, Kostas; Fountas, Kostas N; Zakynthinos, Epaminondas

    2014-01-01

    To assess the prevalence and outcome of external cerebral ventricular drainage-associated ventriculitis in neurocritical patients before and after the implementation of a bundle of external cerebral ventricular drainage-associated ventriculitis control measures. Clinical prospective case series. University Hospital of Larissa, Greece. Consecutive patients were recruited from the ICU of the hospital. Patient inclusion criteria included presence of external ventricular drainage and ICU stay more than 48 hours. The bundle of external cerebral ventricular drainage-associated ventriculitis control measures included 1) reeducation of ICU personnel on issues of infection control related to external cerebral ventricular drainage, 2) meticulous intraventricular catheter handling, 3) cerebrospinal fluid sampling only when clinically necessary, and 4) routine replacement of the drainage catheter on the seventh drainage day if the catheter was still necessary. The bundle was applied after an initial period (preintervention) where standard policy for external cerebral ventricular drainage-associated ventriculitis was established. External cerebral ventricular drainage-associated ventriculitis prevalence, external cerebral ventricular drainage-associated ventriculitis events per 1,000 drainage days (drain-associated infection rate), length of ICU stay, Glasgow Outcome Scale at 6 months, and risk factors for external cerebral ventricular drainage-associated ventriculitis. Eighty-two patients entered the study in the preintervention period and 57 patients during the intervention period. During the preintervention and intervention period, external cerebral ventricular drainage-associated ventriculitis prevalence was 28% and 10.5% (p = 0.02) and drain-associated infection rate was 18 and 7.1, respectively (p = 0.0001); mean (95% CI) length of ICU stay in patients who presented external cerebral ventricular drainage-associated ventriculitis was 44.4 days (36.4-52.4 d), whereas mean

  20. Modes of supraglacial lake drainage and dynamic ice sheet response

    NASA Astrophysics Data System (ADS)

    Das, S. B.; Behn, M. D.; Joughin, I. R.

    2011-12-01

    We investigate modes of supraglacial lake drainage using geophysical, ground, and remote sensing observations over the western margin of the Greenland ice sheet. Lakes exhibit a characteristic life cycle defined by a pre-drainage, drainage, and post-drainage phase. In the pre-drainage phase winter snow fills pre-existing cracks and stream channels, efficiently blocking past drainage conduits. As temperatures increase in the spring, surface melting commences, initially saturating the snow pack and subsequently forming a surface network of streams that fills the lake basins. Basins continue to fill until lake drainage commences, which for individual lakes occurs at different times depending on the previous winter snow accumulation and summer temperatures. Three styles of drainage behavior have been observed: (1) no drainage, (2) slow drainage over the side into an adjacent pre-existing crack, and (3) rapid drainage through a new crack formed beneath the lake basin. Moreover, from year-to-year individual lakes exhibit different drainage behaviors. Lakes that drain slowly often utilize the same outflow channel for multiple years, creating dramatic canyons in the ice. Ultimately, these surface channels are advected out of the lake basin and a new channel forms. In the post-drainage phase, melt water continues to access the bed typically through a small conduit (e.g. moulin) formed near a local topographic minimum along the main drainage crack, draining the lake catchment throughout the remainder of the melt season. This melt water input to the bed leads to continued basal lubrication and enhanced ice flow compared to background velocities. Lakes that do not completely drain freeze over to form a surface ice layer that persists into the following year. Our results show that supraglacial lakes show a spectrum of drainage behaviors and that these styles of drainage lead to varying rates and timing of surface meltwater delivery to the bed resulting in different dynamic ice

  1. Availability of tissue rinse liquid-based cytology for the rapid diagnosis of sentinel lymph node metastasis and improved bilateral detection by photodynamic eye camera.

    PubMed

    Kato, Hidenori; Ohba, Yoko; Yamazaki, Hiroyuki; Minobe, Shin-Ichiro; Sudo, Satoko; Todo, Yukiharu; Okamoto, Kazuhira; Yamashiro, Katsushige

    2015-08-01

    On sentinel lymph node navigation surgery for early invasive cervical cancers, to gain high sensitivity and specificity, the sentinel nodes should be detected bilaterally and pathological diagnosis should be sensitive to detect micrometastasis. To improve these problems, we tried tissue rinse liquid-based cytology and the photodynamic eye. From 2005 to 2013, 102 patients with Stage Ib1 uterine cervical cancer were subjected to sentinel lymph node navigation surgery with Technetium-99 m colloid and blue dye. For the recent 11 patients with whom bilateral sentinel node detection was not available, the photodynamic eye was selectively examined. The detected sentinel node was cut along the minor axis into 2 mm slices, soaked in 10 ml CytoRich red and then subjected to tissue rinse liquid-based cytology at the time of surgery. With the accumulation of 102 Ib1 patients subjected to sentinel lymph node navigation surgery, the bilateral sentinel node detection rate was 67.7%. The photodynamic eye was examined for the recent 11 patients who did not have bilateral signals. Out of the 11, 10 patients obtained bilateral signals successfully. During the period of examining the photodynamic eye, a total of 34 patients were subjected to sentinel lymph node navigation surgery. Thus, the overall bilateral detection rate increased to 97% in this subset. Two hundred and five lymph nodes were available as sentinel nodes. The sensitivity of tissue rinse liquid-based cytology was 91.7%, and the specificity was 100%. False positivity was 0% and false negativity was 8.3%. Detection failure was observed only with one micrometastasis and one case of isolated tumor cells. Combination of photodynamic eye detection and tissue rinse liquid-based cytology pathology can be a promising method for more rewarding sentinel node detection. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. 46 CFR 178.420 - Drainage of cockpit vessels.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Drainage of cockpit vessels. 178.420 Section 178.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.420 Drainage of cockpit...

  3. 46 CFR 178.420 - Drainage of cockpit vessels.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Drainage of cockpit vessels. 178.420 Section 178.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.420 Drainage of cockpit...

  4. 46 CFR 178.420 - Drainage of cockpit vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Drainage of cockpit vessels. 178.420 Section 178.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.420 Drainage of cockpit...

  5. 46 CFR 178.420 - Drainage of cockpit vessels.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Drainage of cockpit vessels. 178.420 Section 178.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.420 Drainage of cockpit...

  6. 46 CFR 178.420 - Drainage of cockpit vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Drainage of cockpit vessels. 178.420 Section 178.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.420 Drainage of cockpit...

  7. Subserosal uterine injection of blue dye for the identification of the sentinel node in patients with endometrial cancer: a feasibility study.

    PubMed

    Biliatis, Ioannis; Thomakos, Nikolaos; Koutroumpa, Ioanna; Haidopoulos, Dimitris; Sotiropoulou, Maria; Antsaklis, Aris; Vlachos, George; Akrivos, Nikolaos; Rodolakis, Alexandros

    2017-09-01

    To define the detection rate, sensitivity, and negative predictive value (NPV) of the sentinel node technique in patients with endometrial cancer. Patients with endometrial cancer after informed consent underwent subserosal injection of blue dye during hysterectomy in a tertiary gynae/oncology department between 2010 and 2014. The procedure was performed in all cases by the same team including two gynae/oncologist consultants and one trainee. All relevant perioperative clinicopathological characteristics of the population were recorded prospectively. The identified sentinel nodes were removed separately and a completion bilateral pelvic lymphadenectomy followed in all cases. Simple statistics were used to calculate the sensitivity and NPV of the method on per patient basis. Fifty-four patients were included in this study. At least one sentinel node was mapped in 46 patients yielding a detection rate of 85.2%. Bilateral detection of sentinel nodes was accomplished in only 31 patients (57.4%). The mean number of sentinel nodes was 2.6 per patient and the commonest site of identification was the external iliac artery and vein area (66%). Six patients (11%) had a positive lymph node, and in five of them, this was the sentinel one yielding a sensitivity of 83.3% and an NPV of 97.5%. The overall detection rate improved significantly after the first 15 cases; however, this was not the case for the bilateral detection rate. Our study is in accordance with previous studies of sentinel node in endometrial cancer and further demonstrates and enhances the confidence in the technique. In the current era of an ongoing debate on whether a systematic lymphadenectomy in patients with endometrial cancer is still necessary, we believe that the sentinel node is an acceptable alternative and should be applied routinely in tertiary centres following a strict algorithm.

  8. Decline in Frozen Section Diagnosis for Axillary Sentinel Lymph Nodes as a Result of the American College of Surgeons Oncology Group Z0011 Trial.

    PubMed

    Bishop, Julie Anne; Sun, Jihong; Ajkay, Nicolas; Sanders, Mary Ann G

    2016-08-01

    -Results of the American College of Surgeons Oncology Group Z0011 trial showed that patients with early-stage breast cancer and limited sentinel node metastasis treated with breast conservation and systemic therapy did not benefit from axillary lymph node dissection. Subsequently, most pathology departments have likely seen a decrease in frozen section diagnosis of sentinel lymph nodes. -To determine the effect of the Z0011 trial on pathology practice and to examine the utility of intraoperative sentinel lymph node evaluation for this subset of patients. -Pathology reports from cases of primary breast cancer that met Z0011 clinical criteria and were initially treated with lumpectomy and sentinel lymph node biopsy from 2009 to 2015 were collected. Clinicopathologic data were recorded. -Sentinel lymph node biopsies sent for frozen section diagnosis occurred in 22 of 22 cases (100%) in 2009 and 15 of 22 cases (68%) in 2010 during the pre-Z0011 years, and in 3 of 151 cases (2%) collected in 2011 through 2015, considered to be post-Z0011 years. Of the 151 post-Z0011 cases, 28 (19%) had sentinel lymph nodes with metastasis, and 147 (97%) were spared axillary lymph node dissection. -Following Z0011, intraoperative sentinel lymph node evaluation has significantly decreased at our institution. Prior to surgery, all patients had clinically node-negative disease. After sentinel lymph node evaluation, 97% (147 of 151) of the patients were spared axillary lymph node dissection. Therefore, routine frozen section diagnosis for sentinel lymph node biopsies can be avoided in these patients.

  9. Automatic Sub-Pixel Co-Registration of LandSat-8 OLI and Sentinel-2A MSI Images Using Phase Correlation and Machine Learning Based Mapping

    NASA Technical Reports Server (NTRS)

    Skakun, Sergii; Roger, Jean-Claude; Vermote, Eric F.; Masek, Jeffrey G.; Justice, Christopher O.

    2017-01-01

    This study investigates misregistration issues between Landsat-8/OLI and Sentinel-2A/MSI at 30 m resolution, and between multi-temporal Sentinel-2A images at 10 m resolution using a phase correlation approach and multiple transformation functions. Co-registration of 45 Landsat-8 to Sentinel-2A pairs and 37 Sentinel-2A to Sentinel-2A pairs were analyzed. Phase correlation proved to be a robust approach that allowed us to identify hundreds and thousands of control points on images acquired more than 100 days apart. Overall, misregistration of up to 1.6 pixels at 30 m resolution between Landsat-8 and Sentinel-2A images, and 1.2 pixels and 2.8 pixels at 10 m resolution between multi-temporal Sentinel-2A images from the same and different orbits, respectively, were observed. The non-linear Random Forest regression used for constructing the mapping function showed best results in terms of root mean square error (RMSE), yielding an average RMSE error of 0.07+/-0.02 pixels at 30 m resolution, and 0.09+/-0.05 and 0.15+/-0.06 pixels at 10 m resolution for the same and adjacent Sentinel-2A orbits, respectively, for multiple tiles and multiple conditions. A simpler 1st order polynomial function (affine transformation) yielded RMSE of 0.08+/-0.02 pixels at 30 m resolution and 0.12+/-0.06 (same Sentinel-2A orbits) and 0.20+/-0.09 (adjacent orbits) pixels at 10 m resolution.

  10. Value of planar lymphoscintigraphy versus SPECT/CT in evaluation of sentinel lymph node in trunk melanoma - one center, large series, retrospective study.

    PubMed

    Benke, Małgorzata; Wocial, Krzysztof; Lewandowska, Weronika; Rutkowski, Piotr Łukasz; Teterycz, Paweł; Jarek, Piotr; Dedecjus, Marek

    2018-06-29

    Background Localization and histopathological examination of sentinel lymph node (SLN) is a standard of melanoma treatment. The first stage of identification of the SLN is the preoperative lymphoscintigraphy. The aim of this study was to assess and compare diagnostic value of planar lymphoscintigraphy (PL) and SPECT/CT in sentinel lymph node biopsy (SLNB) procedure performed in patients with cutaneous trunk melanoma. Material and Methods Between 2015 and 2016, patients with trunk melanoma (N=255, F/M 95/160), aged from 17 to 88 after an excisional biopsy, with primary tumor ≥ pT1b (AJCC 2009, median Breslow thickness 2.0± 3.13) were included in the study. In all the patients PL was followed by SPECT/CT 1-3 h after injection of 99mTc- colloid particles, and SLNB was performed the next day. Results SPECT-CT revealed 78 (18.6%) SLN more than PL, and in 40 patients showed additional lymph drainage regions leading to surgical adjustments. In 18 patients (7.1%) SPECT-CT revealed SLN not visible in the PL (false-negative PL) and in 22 patients (8.6%), foci of uptake interpreted in PL as hot SLNs were found to be non-nodal sites of uptake when assessed on SPECT/CT (false positive PL). SPECT-CT vs. PL mismatch was observed in 31 patients (12.2%) and was the most common in patients with primary lesions located in the anterior inferior medial region (75%). Conclusions Results of the presented study indicates the high diagnostic value of SPECT-CT in assessment of SLNs and proved that SPECT-CT increases the sensitivity and accuracy of SLN identification as compared to PL even in very experienced hands.

  11. Sentinel lymph node biopsy as a prognostic factor in non-metastatic colon cancer: a prospective study.

    PubMed

    Estrada, O; Pulido, L; Admella, C; Hidalgo, L-A; Clavé, P; Suñol, X

    2017-04-01

    Around a third of node-negative patients with colon cancer experience a recurrence after surgery, suggesting poor staging. Sentinel lymph node techniques combined with immunochemistry could improve colon cancer staging. We prospectively assessed the effect of Sentinel node mapping on staging and survival in patients with non-metastatic colon cancer. An observational and prospective study was designed. 105 patients with colon cancer were selected. Patients were classified according to node involvement as: N1, with node invasion detected by the conventional techniques; up-staged, with node invasion detected only by sentinel node mapping; and N0, with negative lymph node involvement by both techniques. Five-year survival and disease-free survival rates were analysed. Multivariate regression analyses were performed to identify prognostic factors for disease-free and overall survival. Sentinel node mapping was successfully applied in 78 patients: 33 % were N1; 24.5 % were up-staged (18 patients with isolated tumour cells and 1 patient with micrometastases); and 42.5 % were N0. N1 patients had the poorest overall 5-year survival (65.4 %) and 5-year disease-free survival (69.2 %) rates compared with the other two groups. No significant 5-year survival differences were observed between N0 patients (87.9 %) and up-staged patients (84.2 %). Patients up-staged after sentinel node mapping do not have a poorer prognosis than patients without node involvement. Detection of isolated cancer cells was not a poor prognosis factor in these patients.

  12. Monitoring Forest Degradation for a Case Study in Cambodia: Comparison of Landsat 8 and Sentinel-2 Imagery

    NASA Astrophysics Data System (ADS)

    Langner, Andreas; Miettinen, Jukka; Stibig, Hans-Jurgen

    2016-08-01

    We use a Normalized Burned Ratio (NBR) differential approach for detecting forest canopy disturbance caused by selective logging in evergreen tropical moist forests of central Cambodia. The general disturbance pattern obtained from Landsat 8 (30 m) imagery is largely compatible to Sentinel-2 (10 m), showing good conformity to high resolution RapidEye reference data. However, the 10 m spatial resolution of Sentinel-2 provides notably higher spatial detail and purer pixel values, increasing the potential for detecting fine and subtle forest canopy changes as indicators for potential forest degradation. We can expect further improvement for detecting short-lived disturbance signals in tropical forest canopies due to an increased revisit frequency (5 days) after the Sentinel-2B launch.

  13. Multicenter Trial of Sentinel Node Biopsy for Breast Cancer Using Both Technetium Sulfur Colloid and Isosulfan Blue Dye

    PubMed Central

    Tafra, Lorraine; Lannin, Donald R.; Swanson, Melvin S.; Van Eyk, Jason J.; Verbanac, Kathryn M.; Chua, Arlene N.; Ng, Peter C.; Edwards, Maxine S.; Halliday, Bradford E.; Henry, C. Alan; Sommers, Linda M.; Carman, Claire M.; Molin, Melinda R.; Yurko, John E.; Perry, Roger R.; Williams, Robert

    2001-01-01

    Objective To determine the factors associated with false-negative results on sentinel node biopsy and sentinel node localization (identification rate) in patients with breast cancer enrolled in a multicenter trial using a combination technique of isosulfan blue with technetium sulfur colloid (Tc99). Summary Background Data Sentinel node biopsy is a diagnostic test used to detect breast cancer metastases. To test the reliability of this method, a complete lymph node dissection must be performed to determine the false-negative rate. Single-institution series have reported excellent results, although one multicenter trial reported a false-negative rate as high as 29% using radioisotope alone. A multicenter trial was initiated to test combined use of Tc99 and isosulfan blue. Methods Investigators (both private-practice and academic surgeons) were recruited after attending a course on the technique of sentinel node biopsy. No investigator participated in a learning trial before entering patients. Tc99 and isosulfan blue were injected into the peritumoral region. Results Five hundred twenty-nine patients underwent 535 sentinel node biopsy procedures for an overall identification rate in finding a sentinel node of 87% and a false-negative rate of 13%. The identification rate increased and the false-negative rate decreased to 90% and 4.3%, respectively, after investigators had performed more than 30 cases. Univariate analysis of tumor showed the poorest success rate with older patients and inexperienced surgeons. Multivariate analysis identified both age and experience as independent predictors of failure. However, with older patients, inexperienced surgeons, and patients with five or more metastatic axillary nodes, the false-negative rate was consistently greater. Conclusions This multicenter trial, from both private practice and academic institutions, is an excellent indicator of the general utility of sentinel node biopsy. It establishes the factors that play an

  14. 46 CFR 178.440 - Drainage of open boats.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Drainage of open boats. 178.440 Section 178.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.440 Drainage of open boats. The deck...

  15. 46 CFR 178.440 - Drainage of open boats.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Drainage of open boats. 178.440 Section 178.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.440 Drainage of open boats. The deck...

  16. 46 CFR 178.440 - Drainage of open boats.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Drainage of open boats. 178.440 Section 178.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.440 Drainage of open boats. The deck...

  17. 46 CFR 178.440 - Drainage of open boats.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Drainage of open boats. 178.440 Section 178.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.440 Drainage of open boats. The deck...

  18. 46 CFR 178.440 - Drainage of open boats.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Drainage of open boats. 178.440 Section 178.440 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) INTACT STABILITY AND SEAWORTHINESS Drainage of Weather Decks § 178.440 Drainage of open boats. The deck...

  19. Geochemical characterisation of seepage and drainage water quality from two sulphide mine tailings impoundments: Acid mine drainage versus neutral mine drainage

    USGS Publications Warehouse

    Heikkinen, P.M.; Raisanen, M.L.; Johnson, R.H.

    2009-01-01

    Seepage water and drainage water geochemistry (pH, EC, O2, redox, alkalinity, dissolved cations and trace metals, major anions, total element concentrations) were studied at two active sulphide mine tailings impoundments in Finland (the Hitura Ni mine and Luikonlahti Cu mine/talc processing plant). The data were used to assess the factors influencing tailings seepage quality and to identify constraints for water treatment. Changes in seepage water quality after equilibration with atmospheric conditions were evaluated based on geochemical modelling. At Luikonlahti, annual and seasonal changes were also studied. Seepage quality was largely influenced by the tailings mineralogy, and the serpentine-rich, low sulphide Hitura tailings produced neutral mine drainage with high Ni. In contrast, drainage from the high sulphide, multi-metal tailings of Luikonlahti represented typical acid mine drainage with elevated contents of Zn, Ni, Cu, and Co. Other factors affecting the seepage quality included weathering of the tailings along the seepage flow path, process water input, local hydrological settings, and structural changes in the tailings impoundment. Geochemical modelling showed that pH increased and some heavy metals were adsorbed to Fe precipitates after net alkaline waters equilibrated with the atmosphere. In the net acidic waters, pH decreased and no adsorption occurred. A combination of aerobic and anaerobic treatments is proposed for Hitura seepages to decrease the sulphate and metal loading. For Luikonlahti, prolonged monitoring of the seepage quality is suggested instead of treatment, since the water quality is still adjusting to recent modifications to the tailings impoundment.

  20. Laparoscopic Sentinel Lymph Node Mapping with Indocyanine Green Using the iSpies Platform: Initial Experience Argentina.

    PubMed

    Di Guilmi, Julian; Darin, Maria Cecilia; Toscano, Maria; Maya, Gustavo

    To demonstrate the initial experience in Argentina using the iSpies indocyanine green (ICG) platform in sentinel lymph node mapping in patients with early-stage cervical cancer. Step-by-step demonstration of the technique using a video and pictures (educative video) (Canadian Task Force classification III). Laparoscopic and robotic sentinel lymph node mapping using ICG has been shown to be safe and feasible; however, in developing countries, the opportunities to use fluorescent imaging through a minimally invasive approach are very limited, given the cost restrictions of acquiring the near-infrared technology and the fluorescent dyes. A 47-year-old woman presented with a stage IB1 squamous cervical cancer. Physical examination revealed a 1.5-cm tumor without evidence of parametrial involvement. Magnetic resonance imaging did not show any evidence of metastatic disease. The patient underwent laparoscopic radical hysterectomy with sentinel lymph node mapping. On laparoscopic exposure of the pelvic spaces, a cervical injection of ICG (1 mL superficial and deep) was administered using a spinal needle at the 3 o'clock and 9 o'clock positions. Sentinel lymph node mapping was then performed using the ICG (Pulsion Medical Systems, Feldkirchen, Germany) and an iSpies near-infrared camera (Karl Storz Endoskope, Tuttlingen, Germany). Bilateral sentinel lymph nodes were detected on the left external iliac artery and in the right obturator space. Both were confirmed ex vivo. The total operative time was 170 minutes. No intraoperative or postoperative complications were reported, and the patient was discharged at 48 hours after surgery. Estimated blood loss was minimal. Sentinel lymph node mapping alone is not the standard of care in our institution, and thus bilateral lymphadenectomy was performed. Ultrastaging is routinely performed when a sentinel lymph node is evaluated. Final pathology revealed a tumor confined to the cervix, with tumor-free margins, and a total of 10

  1. Transurethral Drainage of Prostatic Abscess: Points of Technique

    PubMed Central

    El-Shazly, Mohamed; El- Enzy, Nawaf; El-Enzy, Khaled; Yordanov, Encho; Hathout, Badawy; Allam, Adel

    2012-01-01

    Background The incidence of prostatic abscess (PA) has markedly declined with the widespread use of antibiotics and the decreasing incidence of urethral gonococcal infections. Objectives To evaluate different treatment methods for prostatic abscess and to describe technical points that will improve the outcome of transurethral (TUR) drainage of prostatic abscess. Patients and Methods We performed a retrospective study of a series of 11 patients diagnosed with prostatic abscess, who were admitted and treated in Farwaniya Hospital, Kuwait, between February 2008 and November 2010. Drainage was indicated when antibiotic therapy did not cause clinical improvement and after prostatic abscess was confirmed by TRUS (Transrectal ultrasonography) and/or CT computed Tomographyscan. TUR drainage was indicated in 7 cases, ultrasound-guided transrectal drainage was performed in 2 cases, and ultrasound-guided perineal drainage was performed in 2 cases. Results All patients that underwent TUR-drainage had successful outcomes, without the need of secondary treatment or further surgery. Conclusions TUR drainage of a prostatic abscess increases the likelihood of a successful outcome and lowers the incidence of treatment failure or repeated surgery. Less invasive treatment, with perineal or transrectal aspiration, may be preferred as a primary treatment in relatively young patients with localized abscess cavities. PMID:23573466

  2. A protocol for validating Land Surface Temperature from Sentinel-3

    NASA Astrophysics Data System (ADS)

    Ghent, D.

    2015-12-01

    One of the main objectives of the Sentinel-3 mission is to measure sea- and land-surface temperature with high-end accuracy and reliability in support of environmental and climate monitoring in an operational context. Calibration and validation are thus key criteria for operationalization within the framework of the Sentinel-3 Mission Performance Centre (S3MPC).Land surface temperature (LST) has a long heritage of satellite observations which have facilitated our understanding of land surface and climate change processes, such as desertification, urbanization, deforestation and land/atmosphere coupling. These observations have been acquired from a variety of satellite instruments on platforms in both low-earth orbit and in geostationary orbit. Retrieval accuracy can be a challenge though; surface emissivities can be highly variable owing to the heterogeneity of the land, and atmospheric effects caused by the presence of aerosols and by water vapour absorption can give a bias to the underlying LST. As such, a rigorous validation is critical in order to assess the quality of the data and the associated uncertainties. The Sentinel-3 Cal-Val Plan for evaluating the level-2 SL_2_LST product builds on an established validation protocol for satellite-based LST. This set of guidelines provides a standardized framework for structuring LST validation activities, and is rapidly gaining international recognition. The protocol introduces a four-pronged approach which can be summarised thus: i) in situ validation where ground-based observations are available; ii) radiance-based validation over sites that are homogeneous in emissivity; iii) intercomparison with retrievals from other satellite sensors; iv) time-series analysis to identify artefacts on an interannual time-scale. This multi-dimensional approach is a necessary requirement for assessing the performance of the LST algorithm for SLSTR which is designed around biome-based coefficients, thus emphasizing the importance of

  3. 24 CFR 3285.604 - Drainage system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Drainage system. 3285.604 Section... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Ductwork and Plumbing and Fuel Supply Systems § 3285.604 Drainage system. (a) Crossovers. Multi-section homes with plumbing in more than one section...

  4. 24 CFR 3285.604 - Drainage system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Drainage system. 3285.604 Section... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Ductwork and Plumbing and Fuel Supply Systems § 3285.604 Drainage system. (a) Crossovers. Multi-section homes with plumbing in more than one section...

  5. High Resolution Mapping of Wetland Ecosystems SPOT-5 Take 5 for Evaluation of Sentinel-2

    NASA Astrophysics Data System (ADS)

    Ade, Christiana; Hestir, Erin L.; Khanna, Shruti; Ustin, Susan L.

    2016-08-01

    Around the world wetlands are critical to human societies and ecosystems, providing services such as habitat, water, food and fiber, flood and nutrient control, and cultural, recreational and religious value. However, the dynamic nature of tidal wetlands makes measuring ecosystem responses to climate change, seasonal inundation regimes, and anthropogenic disturbance from current and previous Earth observing sensors challenging due to limited spatial and temporal resolutions. Sentinel- 2 will directly address this challenge by providing high spatial resolution data with frequent revisit time. This pilot study aims to develop methodology for future Sentinel-2 products and highlight the variability of tidal wetland ecosystems, thereby demonstrating the necessity of improved spatial particularly temporal resolution. Here the simulated Sentinel-2 dataset from the SPOT-5 Take 5 experiment reveals the capacity of the new sensor to simultaneously assess tidal wetland ecosystem phenology and water quality in inland waters.

  6. Evaluation of the Sentinel-3 Hydrologic Altimetry Processor prototypE (SHAPE) methods.

    NASA Astrophysics Data System (ADS)

    Benveniste, J.; Garcia-Mondéjar, A.; Bercher, N.; Fabry, P. L.; Roca, M.; Varona, E.; Fernandes, J.; Lazaro, C.; Vieira, T.; David, G.; Restano, M.; Ambrózio, A.

    2017-12-01

    Inland water scenes are highly variable, both in space and time, which leads to a much broader range of radar signatures than ocean surfaces. This applies to both LRM and "SAR" mode (SARM) altimetry. Nevertheless the enhanced along-track resolution of SARM altimeters should help improve the accuracy and precision of inland water height measurements from satellite. The SHAPE project - Sentinel-3 Hydrologic Altimetry Processor prototypE - which is funded by ESA through the Scientific Exploitation of Operational Missions Programme Element (contract number 4000115205/15/I-BG) aims at preparing for the exploitation of Sentinel-3 data over the inland water domain. The SHAPE Processor implements all of the steps necessary to derive rivers and lakes water levels and discharge from Delay-Doppler Altimetry and perform their validation against in situ data. The processor uses FBR CryoSat-2 and L1A Sentinel-3A data as input and also various ancillary data (proc. param., water masks, L2 corrections, etc.), to produce surface water levels. At a later stage, water level data are assimilated into hydrological models to derive river discharge. This poster presents the improvements obtained with the new methods and algorithms over the regions of interest (Amazon and Danube rivers, Vanern and Titicaca lakes).

  7. Sentinel monitoring of general community health during the 1998 World Football Cup.

    PubMed

    Hanslik, T; Espinoza, P; Boelle, P Y; Cantin-Bertaux, D; Gallichon, B; Quendez, S; Aïm, J L; Retel, O; Ballereau, M; Gorodetzky, N; Flahault, A

    2001-04-01

    Present knowledge of the consequences of mass gatherings for the health of the community is scant. Our objective was to determine the impact of the 1998 World Football Cup on general community health. We set up an electronic sentinel disease surveillance, before, during and after the World Football Cup tournament held in France from June 10 to July 12, 1998. Medical activity, and the daily number of cases of communicable, environmental, and societal diseases relating to mass gatherings were surveyed. The incidence of the pathologies surveyed in real time during and after the World Cup versus the pre-Cup reference period was the main outcome measure. Five sentinel networks participated, comprising 553 general practitioners, 60 hospital adult emergency departments, 19 private emergency community services, 4 community health centres, and the medical centre of the Paris airports. Throughout the 66-day study period, physicians reported 558,829 medical encounters via 21,532 connections to the computer. Compared to the reference period, the level of medical activity reflected by the pathological items surveyed remained stable during the study period. The 1998 World Football Cup had no epidemiological impact on general community health, as observed by sentinel networks located downstream of the specific health services provided by the French authorities to ensure high standards of safety.

  8. Sentinel lymph node biopsy in cutaneous melanoma of the head and neck using the indocyanine green SPY Elite system.

    PubMed

    Vahabzadeh-Hagh, Andrew M; Blackwell, Keith E; Abemayor, Elliot; St John, Maie A

    2018-05-17

    Lymph node status is the single most important prognostic factor for patients with early-stage cutaneous melanoma. Sentinel lymph node biopsy (SLNB) has become the standard of care for intermediate depth melanomas. Modern SLNB implementation includes technetium-99 lymphoscintigraphy combined with local administration of a vital blue dye. However, sentinel lymph nodes may fail to localize in some cases and false-negative rates range from 0 to 34%. Here we demonstrate the feasibility of a new sentinel lymph node biopsy technique using indocyanine green (ICG) and the SPY Elite near-infrared imaging system. Cases of primary cutaneous melanoma of the head and neck without locoregional metastasis, underwent SLNB at a single quaternary care institution between May 2016 and June 2017. Intraoperatively, 0.25 mL of ICG was injected intradermal in 4 quadrants around the primary lesion. 10-15 minute circulation time was permitted. SPY Elite identified the sentinel lymph node within the nodal basin marked by lymphoscintigraphy. Target first echelon lymph nodes were confirmed with a gamma probe and ICG fluorescence. 14 patients were included with T1a to T4b cutaneous melanomas. Success rates for sentinel lymph node identification using lymphoscintigraphy and the SPY Elite system were both 86%. Zero false negatives occurred. Median length of follow-up was 323 days. In this pilot study, Indocyanine green near-infrared fluorescence demonstrates a safe, and facile method of sentinel lymph node biopsy for cutaneous melanoma of the head and neck compared with lymphoscintigraphy and vital blue dyes. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Outcome of Sentinel Hospital-based and CDC-based ART Service Delivery: A Prospective Open Cohort of People Living with HIV in China.

    PubMed

    Ning, Chuanyi; Smith, Kumi M; McCann, Chase D; Hu, Fengyu; Lan, Yun; Zhang, Fuchun; Liang, Hao; Zhao, Jinmin; Tucker, Joseph D; Cai, Weiping

    2017-02-14

    The primary objective of this study was to obtain insights into the outcomes of people living with HIV who accessed services through HIV/AIDS sentinel hospital-based and ART service delivery in China. Post-hoc analyses of an open cohort from an observational database of 22 qualified HIV/AIDS sentinel hospital-based and two CDC-based drug delivery facilities (DDFs) in Guangdong Province was completed. Linkage to care, mortality and survival rates were calculated according to WHO criteria. 12,966 individuals received ART from HIV/AIDS sentinel hospitals and 1,919 from DDFs, with linkage to care rates of 80.7% and 79.9%, respectively (P > 0.05). Retention rates were 94.1% and 84.0% in sentinel hospitals and DDFs, respectively (P < 0.01). Excess mortality was 1.4 deaths/100 person-years (95% CI: 1.1, 1.8) in DDFs compared to 0.4 deaths/100 person-years (95% CI: 0.3, 0.5) in hospitals (P < 0.01). A Cox-regression analysis revealed that mortality was much higher in patients receiving ART from the DDFs than sentinel hospitals, with an adjusted HR of 3.3 (95% CI: 2.3, 4.6). A crude HR of treatment termination in DDFs was 7.5 fold higher (95% CI: 6.3, 9.0) compared to sentinel hospitals. HIV/AIDS sentinel hospital had better retention, and substantially lower mortality compared to DDFs.

  10. Design of bridge deck drainage : HEC 21

    DOT National Transportation Integrated Search

    1993-05-01

    The manual provides guidelines and procedures for designing bridge deck drainage systems, inclusing illustrative examples. Should the design process indicate a drainage system is needed, utilization of the most hydraulically efficient and maintenance...

  11. Clinical and histopathological factors affecting failed sentinel node localization in axillary staging for breast cancer.

    PubMed

    Dordea, Matei; Colvin, Hugh; Cox, Phil; Pujol Nicolas, Andrea; Kanakala, Venkat; Iwuchukwu, Obi

    2013-04-01

    Sentinel lymph node biopsy (SLNB) has become the standard of care in axillary staging of clinically node-negative breast cancer patients. To analyze reasons for failure of SLN localization by means of a multivariate analysis of clinical and histopathological factors. We performed a review of 164 consecutive breast cancer patients who underwent SLNB. A superficial injection technique was used. 9/164 patients failed to show nodes. In 7/9 patients no evidence of radioactivity or blue dye was observed. Age and nodal status were the only statistically significant factors (p < 0.05). For every unit increase in age there was a 9% reduced chance of failed SLN localization. Patients with negative nodal status have 90% reduced risk of failed sentinel node localization than patients with macro or extra capsular nodal invasion. The results suggest that altered lymphatic dynamics secondary to tumour burden may play a role in failed sentinel node localization. We showed that in all failed localizations the radiocolloid persisted around the injection site, showing limited local diffusion only. While clinical and histopathological data may provide some clues as to why sentinel node localization fails, we further hypothesize that integrity of peri-areolar lymphatics is important for successful localization. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  12. Exploring the potential of Sentinel-1 data for regional scale slope instability detection using multi-temporal interferometry

    NASA Astrophysics Data System (ADS)

    Wasowski, Janusz; Bovenga, Fabio; Nutricato, Raffaele; Nitti, Davide Oscar; Chiaradia, Maria Teresa; Refice, Alberto; Pasquariello, Guido

    2016-04-01

    Launched in 2014, the European Space Agency (ESA) Sentinel-1 satellite carrying a medium resolution (20 m) C-Band Synthetic Aperture Radar (SAR) sensor holds much promise for new applications of multi-temporal interferometry (MTI) in landslide assessment. Specifically, the regularity of acquisitions, timeliness of data delivery, shorter repeat cycle (currently 12 days with Sentinel-1A sensor), and flexible incidence angle geometry, all imply better practical utility of MTI relying on Sentinel-1 with respect to MTI based on data from earlier ESA's satellite radar C-band sensors (ERS1/2, ENVISAT). Furthermore, the upcoming launch of Sentinel-1B will cut down the repeat cycle to 6 days, thereby further improving temporal coherence and quality and coverage of MTI products. Taking advantage of the Interferometric Wide (IW) Swath acquisition mode of Sentinel-1 (images covering a 250 km swath on the ground), in this work we test the potential of such data for regional scale slope instability detection through MTI. Our test area includes the landslide-prone Apennine Mountains of Southern Italy. We rely on over 30 Sentinel-1 images, most of which acquired in 2015, and MTI processing through the SPINUA algorithm (Stable Points INterferometry in Un-urbanized Areas). The potential of MTI results based on Sentinel-1 data is assessed by comparing the detected ground surface displacements with the MTI results obtained for the same test area using the C-Band data acquired by ERS1/2 and ENVISAT in 1990s and 2000s. Although the initial results are encouraging, it seems evident that longer-term (few years) acquisitions of Sentinel-1 are necessary to reliably detect some extremely slow movements, which were observed in the last two decades and are likely to be still present in peri-urban areas of many hilltop towns in the Apennine Mts. The MTI results obtained from Sentinel-1 data are also locally compared with the MTI outcomes based on the high resolution (3 m) TerraSAR-X imagery

  13. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery

    PubMed Central

    Zheng, Qiong; Huang, Wenjiang; Cui, Ximin; Liu, Linyi

    2018-01-01

    Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI), a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe) in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor’s relative spectral response (RSR) function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red), B5 (Re1), and B7 (Re3), were found to be sensitive bands using the random forest (RF) method. A new multispectral index, the Red Edge Disease Stress Index (REDSI), which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI’s ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and generalized

  14. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery.

    PubMed

    Zheng, Qiong; Huang, Wenjiang; Cui, Ximin; Shi, Yue; Liu, Linyi

    2018-03-15

    Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI), a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe) in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor's relative spectral response (RSR) function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red), B5 (Re1), and B7 (Re3), were found to be sensitive bands using the random forest (RF) method. A new multispectral index, the Red Edge Disease Stress Index (REDSI), which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI's ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and generalized ability

  15. Sentinel-1 Radar Shows Ground Motion From Sept. 2017 Oaxaca-Chiapas, Mexico Quake

    NASA Image and Video Library

    2017-09-20

    NASA and its partners are contributing important observations and expertise to the ongoing response to the Sept. 7, 2017 (local time), magnitude 8.1 Oaxaca-Chiapas earthquake in Mexico. This earthquake was the strongest in more than a century in Mexico. It has caused a significant humanitarian crisis, with widespread building damage and triggered landslides throughout the region. Scientists with the Advanced Rapid Imaging and Analysis project (ARIA), a collaboration between NASA's Jet Propulsion Laboratory in Pasadena, California; and Caltech, also in Pasadena, analyzed interferometric synthetic aperture radar images from the radar instrument on the Copernicus Sentinel-1A and Sentinel-1B satellites operated by the European Space Agency (ESA) to calculate a map of the deformation of Earth's surface caused by the quake. This false-color map shows the amount of permanent surface movement caused almost entirely by the earthquake, as viewed by the satellite, during a six-day interval between radar images acquired by the two Sentinel-1 satellites on Sept. 7 and Sept. 13, 2017. In this map, the colors of the surface displacements are proportional to the surface motion. The red tones show the areas along the coast of Chiapas and Oaxaca have moved toward the satellite by as much as 9 inches (22 centimeters) in a combination of up and eastward motion. The area in between and farther north with various shades of blue moved away from the satellite, mostly downward or westward, by as much as 6 inches (15 centimeters). Areas without color are open water or heavy vegetation, which prevent the radar from measuring change between the satellite images. Scientists use these maps to build detailed models of the fault slip at depth and associated land movements to better understand the impact on future earthquake activity. The green star shows the location of the earthquake epicenter estimated by the United States Geological Survey (USGS) National Earthquake Information Center. Map

  16. From CryoSat-2 to Sentinel-3 and Beyond

    NASA Astrophysics Data System (ADS)

    Francis, R.

    2011-12-01

    CryoSat-2 carried into Earth orbit the first altimeter using SAR principles, although similar techniques had been used on earlier Venusian missions. Furthermore, it carries a second antenna and receive chain, and has been very carefully calibrated, allowing interferometry between these antennas. The results of the SAR mode and of the interferometer have met all expectations, with handsome margins. Even before the launch of CryoSat-2 the further development of this concept was underway with the radar for the oceanography mission Sentinel-3. While this radar, named SRAL (SAR Radar Altimeter) does not have the interferometer capability of CryoSat-2's SIRAL (SAR Interferometric Radar Altimeter), it does have a second frequency, to enable direct measurement of the delay induced by the ionospheric electron content. Sentinel-3 will have a sun-synchronous orbit, like ERS and EnviSat, and will have a similar latitudinal range: about 82° north and south, compared to CryoSat's 88°. Sentinel-3 will operate its radar altimeter in the high-resolution SAR mode over coastal oceans and inland water, and will revert to the more classical pulse-width limited mode over the open oceans. The SAR mode generates data at a high rate, so the major limiting factor is the amount of on-board storage. The power consumption is also higher, imposing less critical constraints. For sizing purposes the coastal oceans are defined as waters within 300 km of the continental shorelines. Sentinel-3 is expected to be launched in 2013 and be followed 18 months later by a second satellite of the same design. The next step in the development of this family of radar altimeters is Jason-CS, which will provide Continuity of Service to the existing Jason series of operational oceanography missions. Jason-CS has a very strong heritage from CryoSat but will fly the traditional Jason orbit, which covers latitudes up to 66° from a high altitude of 1330 km. The new radar is called Poseidon-4, to emphasise the

  17. ANIMALS AS SENTINELS OF HUMAN HEALTH HAZARDS OF ENVIRONMENTAL CHEMICALS

    EPA Science Inventory

    A workshop titled "Using Sentinel Species Data to Address the Potential Human Health Effects of Chemicals in the Environmnet," sponsored by the U.S. Army Center for Environmental Health Research, the National Center for Environmental Assessment of the EPA, and the Agency for Toxi...

  18. Foamed emulsion drainage: flow and trapping of drops.

    PubMed

    Schneider, Maxime; Zou, Ziqiang; Langevin, Dominique; Salonen, Anniina

    2017-06-07

    Foamed emulsions are ubiquitous in our daily life but the ageing of such systems is still poorly understood. In this study we investigate foam drainage and measure the evolution of the gas, liquid and oil volume fractions inside the foam. We evidence three regimes of ageing. During an initial period of fast drainage, both bubbles and drops are very mobile. As the foam stabilises drainage proceeds leading to a gradual decrease of the liquid fraction and slowing down of drainage. Clusters of oil drops are less sheared, their dynamic viscosity increases and drainage slows down even further, until the drops become blocked. At this point the oil fraction starts to increase in the continuous phase. The foam ageing leads to an increase of the capillary pressure until the oil acts as an antifoaming agent and the foam collapses.

  19. Priority Scale of Drainage Rehabilitation of Cilacap City

    NASA Astrophysics Data System (ADS)

    Rudiono, Jatmiko

    2018-03-01

    Characteristics of physical condition of Cilacap City is relatively flat and low to sea level (approximately 6 m above sea level). In the event of a relatively heavy rainfall resulting in inundation at several locations. The problem of inundation is a serious problem if there is in a dense residential area or occurs in publicly-used infrastructure, such as roads and settlements. These problems require improved management of which include how to plan a sustainable urban drainage system and environmentally friendly. The development of Cilacap City is increasing rapidly, this causes drainage system based on the Drainage Masterplan Cilacap made in 2006 has not been able to accommodate rain water, so, it is necessary to evaluate the drainage masterplan for subsequent rehabilitation. Priority scale rehabilitation of the drainage sections as a guideline is an urgent need of rehabilitation in the next time period.

  20. Operational multisensor sea ice concentration algorithm utilizing Sentinel-1 and AMSR2 data

    NASA Astrophysics Data System (ADS)

    Dinessen, Frode

    2017-04-01

    The Norwegian Ice Service provide ice charts of the European part of the Arctic every weekday. The charts are produced from a manually interpretation of satellite data where SAR (Synthetic Aperture Radar) data plays a central role because of its high spatial resolution and Independence of cloud cover. A new chart is produced every weekday and the charts are distributed through the CMEMS portal. After the launch of Sentinel-1A and B the number of available SAR data have significant increased making it difficult to utilize all the data in a manually process. This in combination with a user demand for a more frequent update of the ice conditions, also during the weekends, have made it important to focus the development on utilizing the high resolution Sentinel-1 data in an automatic sea ice concentration analysis. The algorithm developed here is based on a multi sensor approach using an optimal interpolation to combine sea ice concentration products derived from Sentinel-1 and passive microwave data from AMSR2. The Sentinel-1 data is classified with a Bayesian SAR classification algorithm using data in extra wide mode dual polarization (HH/HV) to separate ice and water in the full 40x40 meter spatial resolution. From the classification of ice/water the sea ice concentration is estimated by calculating amount of ice within an area of 1x1 km. The AMSR2 sea ice concentration are produced as part of the EUMETSAT Ocean and Sea Ice Satellite Application Facility (OSI SAF) project and utilize the 89 GHz channel to produce a concentration product with a 3km spatial resolution. Results from the automatic classification will be presented.

  1. Satellite radar interferometry for monitoring subsidence induced by longwall mining activity using Radarsat-2, Sentinel-1 and ALOS-2 data

    NASA Astrophysics Data System (ADS)

    Ng, Alex Hay-Man; Ge, Linlin; Du, Zheyuan; Wang, Shuren; Ma, Chao

    2017-09-01

    This paper describes the simulation and real data analysis results from the recently launched SAR satellites, ALOS-2, Sentinel-1 and Radarsat-2 for the purpose of monitoring subsidence induced by longwall mining activity using satellite synthetic aperture radar interferometry (InSAR). Because of the enhancement of orbit control (pairs with shorter perpendicular baseline) from the new satellite SAR systems, the mine subsidence detection is now mainly constrained by the phase discontinuities due to large deformation and temporal decorrelation noise. This paper investigates the performance of the three satellite missions with different imaging modes for mapping longwall mine subsidence. The results show that the three satellites perform better than their predecessors. The simulation results show that the Sentinel-1A/B constellation is capable of mapping rapid mine subsidence, especially the Sentinel-1A/B constellation with stripmap (SM) mode. Unfortunately, the Sentinel-1A/B SM data are not available in most cases and hence real data analysis cannot be conducted in this study. Despite the Sentinel-1A/B SM data, the simulation and real data analysis suggest that ALOS-2 is best suited for mapping mine subsidence amongst the three missions. Although not investigated in this study, the X-band satellites TerraSAR-X and COSMO-SkyMed with short temporal baseline and high spatial resolution can be comparable with the performance of the Radarsat-2 and Sentinel-1 C-band data over the dry surface with sparse vegetation. The potential of the recently launched satellites (e.g. ALOS-2 and Sentinel-1A/B) for mapping longwall mine subsidence is expected to be better than the results of this study, if the data acquired from the ideal acquisition modes are available.

  2. Validation of Land Surface Temperature from Sentinel-3

    NASA Astrophysics Data System (ADS)

    Ghent, D.

    2017-12-01

    One of the main objectives of the Sentinel-3 mission is to measure sea- and land-surface temperature with high-end accuracy and reliability in support of environmental and climate monitoring in an operational context. Calibration and validation are thus key criteria for operationalization within the framework of the Sentinel-3 Mission Performance Centre (S3MPC). Land surface temperature (LST) has a long heritage of satellite observations which have facilitated our understanding of land surface and climate change processes, such as desertification, urbanization, deforestation and land/atmosphere coupling. These observations have been acquired from a variety of satellite instruments on platforms in both low-earth orbit and in geostationary orbit. Retrieval accuracy can be a challenge though; surface emissivities can be highly variable owing to the heterogeneity of the land, and atmospheric effects caused by the presence of aerosols and by water vapour absorption can give a bias to the underlying LST. As such, a rigorous validation is critical in order to assess the quality of the data and the associated uncertainties. Validation of the level-2 SL_2_LST product, which became freely available on an operational basis from 5th July 2017 builds on an established validation protocol for satellite-based LST. This set of guidelines provides a standardized framework for structuring LST validation activities. The protocol introduces a four-pronged approach which can be summarised thus: i) in situ validation where ground-based observations are available; ii) radiance-based validation over sites that are homogeneous in emissivity; iii) intercomparison with retrievals from other satellite sensors; iv) time-series analysis to identify artefacts on an interannual time-scale. This multi-dimensional approach is a necessary requirement for assessing the performance of the LST algorithm for the Sea and Land Surface Temperature Radiometer (SLSTR) which is designed around biome

  3. Agricultural drainage and wetland management in Ontario.

    PubMed

    Walters, Dan; Shrubsole, Dan

    2003-12-01

    Land drainage is recognized as an integral part of agricultural activity throughout the world. However, the increase in agricultural production has resulted in the loss of wetland functions and values. Therefore, wetland management and agricultural drainage illustrate the conflict between economic development and natural values. This research assesses the approval process for agricultural land drainage in Ontario, Canada, to determine how the benefits of increased agricultural production are balanced against the loss of wetland values. A permit review of drainage applications was conducted from 1978 to 1997 in Zorra Township, Ontario, Canada. Data collection also included the document reviews, interviews with government agencies and wetland evaluation files. The selected criteria include efficiency, equity, consistency and adequacy. The results indicate that while the process is efficient, fundamental problems remain with the bargaining process.

  4. Harmonized Landsat/Sentinel-2 Reflectance Products for Land Monitoring

    NASA Astrophysics Data System (ADS)

    Masek, J. G.; Ju, J.; Claverie, M.; Vermote, E.; Dungan, J. L.; Roger, J. C.; Skakun, S.; Justice, C. O.

    2017-12-01

    Many land applications require more frequent observations than can be obtained from a single "Landsat class" sensor. Agricultural monitoring, inland water quality assessment, stand-scale phenology, and numerous other applications all require near-daily imagery at better than 1ha resolution. Thus the land science community has begun expressing a desire for a "30-meter MODIS" global monitoring capability. One cost-effective way to achieve this goal is via merging data from multiple, international observatories into a single virtual constellation. The Harmonized Landsat/Sentinel-2 (HLS) project has been working to generate a seamless surface reflectance product by combining observations from USGS/NASA Landsat-8 and ESA Sentinel-2. Harmonization in this context requires a series of radiometric and geometric transforms to create a single surface reflectance time series agnostic to sensor origin. Radiometric corrections include a common atmospheric correction using the Landsat-8 LaSRC/6S approach, a simple BRDF adjustment to constant solar and nadir view angle, and spectral bandpass adjustments to fit the Landsat-8 OLI reference. Data are then resampled to a consistent 30m UTM grid, using the Sentinel-2 global tile system. Cloud and shadow masking are also implemented. Quality assurance (QA) involves comparison of the output 30m HLS products with near-simultaneous MODIS nadir-adjusted observations. Prototoype HLS products have been processed for 7% of the global land area using the NASA Earth Exchange (NEX) compute environment at NASA Ames, and can be downloaded from the HLS web site (https://hls.gsfc.nasa.gov). A wall-to-wall North America data set is being prepared for 2018.This talk will review the objectives and status of the HLS project, and illustrate applications of high-density optical time series data for agriculture and ecology. We also discuss lessons learned from HLS in the general context of implementing virtual constellations.

  5. Robust Flood Monitoring Using Sentinel-1 SAR Time Series

    NASA Astrophysics Data System (ADS)

    DeVries, B.; Huang, C.; Armston, J.; Huang, W.

    2017-12-01

    The 2017 hurricane season in North and Central America has resulted in unprecedented levels of flooding that have affected millions of people and continue to impact communities across the region. The extent of casualties and damage to property incurred by these floods underscores the need for reliable systems to track flood location, timing and duration to aid response and recovery efforts. While a diverse range of data sources provide vital information on flood status in near real-time, only spaceborne Synthetic Aperture Radar (SAR) sensors can ensure wall-to-wall coverage over large areas, mostly independently of weather conditions or site accessibility. The European Space Agency's Sentinel-1 constellation represents the only SAR mission currently providing open access and systematic global coverage, allowing for a consistent stream of observations over flood-prone regions. Importantly, both the data and pre-processing software are freely available, enabling the development of improved methods, tools and data products to monitor floods in near real-time. We tracked flood onset and progression in Southeastern Texas, Southern Florida, and Puerto Rico using a novel approach based on temporal backscatter anomalies derived from times series of Sentinel-1 observations and historic baselines defined for each of the three sites. This approach was shown to provide a more objective measure of flood occurrence than the simple backscatter thresholds often employed in operational flood monitoring systems. Additionally, the use of temporal anomaly measures allowed us to partially overcome biases introduced by varying sensor view angles and image acquisition modes, allowing increased temporal resolution in areas where additional targeted observations are available. Our results demonstrate the distinct advantages offered by data from operational SAR missions such as Sentinel-1 and NASA's planned NISAR mission, and call attention to the continuing need for SAR Earth Observation

  6. Sentinel visits in emergency department patients with diabetes mellitus as a warning sign for hyperglycemic emergencies.

    PubMed

    Yan, Justin W; Gushulak, Katherine M; Columbus, Melanie P; Hamelin, Alexandra L; Wells, George A; Stiell, Ian G

    2018-03-01

    Patients with poorly controlled diabetes mellitus may have a sentinel emergency department (ED) visit for a precipitating condition prior to presenting for a hyperglycemic emergency, such as diabetic ketoacidosis (DKA) or hyperosmolar hyperglycemic state (HHS). This study's objective was to describe the epidemiology and outcomes of patients with a sentinel ED visit prior to their hyperglycemic emergency visit. This was a 1-year health records review of patients≥18 years old presenting to one of four tertiary care EDs with a discharge diagnosis of hyperglycemia, DKA, or HHS. Trained research personnel collected data on patient characteristics, management, disposition, and determined whether patients came to the ED within the 14 days prior to their hyperglycemia visit. Descriptive statistics were used to summarize the data. Of 833 visits for hyperglycemia, 142 (17.0%; 95% CI: 14.5% to 19.6%) had a sentinel ED presentation within the preceding 14 days. Mean (SD) age was 50.5 (19.0) years and 54.4% were male; 104 (73.2%) were discharged from this initial visit, and 98/104 (94.2%) were discharged either without their glucose checked or with an elevated blood glucose (>11.0 mmol/L). Of the sentinel visits, 93 (65.5%) were for hyperglycemia and 22 (15.5%) for infection. Upon returning to the ED, 61/142 (43.0%) were admitted for severe hyperglycemia, DKA, or HHS. In this unique ED-based study, diabetic patients with a sentinel ED visit often returned and required subsequent admission for hyperglycemia. Clinicians should be vigilant in checking blood glucose and provide clear discharge instructions for follow-up and glucose management to prevent further hyperglycemic emergencies from occurring.

  7. Sentinel model for influenza A virus monitoring in free-grazing ducks in Thailand.

    PubMed

    Boonyapisitsopa, Supanat; Chaiyawong, Supassama; Nonthabenjawan, Nutthawan; Jairak, Waleemas; Prakairungnamthip, Duangduean; Bunpapong, Napawan; Amonsin, Alongkorn

    2016-01-01

    Influenza A virus (IAV) can cause influenza in birds and mammals. In Thailand, free-grazing ducks are known IAV reservoirs and can spread viruses through frequent movements in habitats they share with wild birds. In this study, the sentinel model for IAV monitoring was conducted over 4 months in two free-grazing duck flocks. IAV subtypes H4N6 (n=1) and H3N8 (n=5) were isolated from sentinel ducks at the ages of 13 and 15 weeks. Clinical signs of depression and ocular discharge were observed in the infected ducks. Phylogenetic analysis and genetic characterization of the isolated IAVs indicated that all Thai IAVs were clustered in the Eurasian lineage and pose low pathogenic avian influenza characteristics. Serological analysis found that antibodies against IAVs could be detected in the ducks since 9-weeks-old. In summary, our results indicate that the sentinel model can be used for IAV monitoring in free-grazing duck flocks. Since free-grazing ducks are potential reservoirs and transmitters of IAVs, routine IAV surveillance in free-grazing duck flocks can be beneficial for influenza prevention and control strategies. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Sentinel lymph node mapping in endometrial cancer: a systematic review and meta-analysis.

    PubMed

    Lin, Hefeng; Ding, Zheyuan; Kota, Vishnu Goutham; Zhang, Xiaoming; Zhou, Jianwei

    2017-07-11

    Endometrial cancer is the most frequent tumor in the female reproductive system, while the sentinel lymph node (SLN) mapping for diagnostic efficacy of endometrial cancer is still controversial. This meta-analysis was conducted to evaluate the diagnostic value of SLN in the assessment of lymph nodal involvement in endometrial cancer. Forty-four studies including 2,236 cases were identified. The pooled overall detection rate was 83% (95% CI: 80-86%). The pooled sensitivity was 91% (95% CI: 87-95%). The bilateral pelvic node detection rate was 56% (95% CI: 48-64%). Use of indocyanine green (ICG) increased the overall detection rate to 93% (95% CI: 89-96%) and robotic-assisted surgery also increased the overall detection rate to 86% (95% CI: 79-93%). In summary, our meta-analysis provides strong evidence that sentinel node mapping is an accurate and feasible method that performs well diagnostically for the assessment of lymph nodal involvement in endometrial cancer. Cervical injection, robot-assisted surgery, as well as using ICG, optimized the sensitivity and detection rate of the technique. Sentinel lymph mapping may potentially leading to a greater utilization by gynecologic surgeons in the future.

  9. Red Fox as Sentinel for Blastomyces dermatitidis, Ontario, Canada.

    PubMed

    Nemeth, Nicole M; Campbell, G Douglas; Oesterle, Paul T; Shirose, Lenny; McEwen, Beverly; Jardine, Claire M

    2016-07-01

    Blastomyces dermatitidis, a fungus that can cause fatal infection in humans and other mammals, is not readily recoverable from soil, its environmental reservoir. Because of the red fox's widespread distribution, susceptibility to B. dermatitidis, close association with soil, and well-defined home ranges, this animal has potential utility as a sentinel for this fungus.

  10. Trace Chemical Detection through Vegetation Sentinels and Fluorescence Spectroscopy

    Treesearch

    John E. Anderson; Robert L. Fischer; Jean D. Nelson

    2006-01-01

    Detection of environmental contaminants through vegetation sentinels has long been a goal of remote sensing scientists. A promising technique that should be scalable to wide-area applications is the combined use of genetically modified vascular plants and fluorescence imaging. The ultimate goal of our research is to produce a bioreporter that will express fluorescence...

  11. 9 CFR 354.223 - Drainage and plumbing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... approved traps and vents. The drainage and plumbing system must permit the quick runoff of all water from... covers. (3) Toilet soil lines shall be separate from house drainage lines to a point outside the...

  12. Sentinel lymph nodes detection with an imaging system using Patent Blue V dye as fluorescent tracer

    NASA Astrophysics Data System (ADS)

    Tellier, F.; Steibel, J.; Chabrier, R.; Rodier, J. F.; Pourroy, G.; Poulet, P.

    2013-03-01

    Sentinel lymph node biopsy is the gold standard to detect metastatic invasion from primary breast cancer. This method can help patients avoid full axillary chain dissection, thereby decreasing the risk of morbidity. We propose an alternative to the traditional isotopic method, to detect and map the sentinel lymph nodes. Indeed, Patent Blue V is the most widely used dye in clinical routine for the visual detection of sentinel lymph nodes. A Recent study has shown the possibility of increasing the fluorescence quantum yield of Patent Blue V, when it is bound to human serum albumin. In this study we present a preclinical fluorescence imaging system to detect sentinel lymph nodes labeled with this fluorescent tracer. The setup is composed of a black and white CCD camera and two laser sources. One excitation source with a laser emitting at 635 nm and a second laser at 785 nm to illuminate the region of interest. The prototype is operated via a laptop. Preliminary experiments permitted to determine the device sensitivity in the μmol.L-1 range as regards the detection of PBV fluorescence signals. We also present a preclinical evaluation performed on Lewis rats, during which the fluorescence imaging setup detected the accumulation and fixation of the fluorescent dye on different nodes through the skin.

  13. Sentinel Node Mapping Using a Fluorescent Dye and Visible Light During Laparoscopic Gastrectomy for Early Gastric Cancer: Result of a Prospective Study From a Single Institute.

    PubMed

    Lee, Chang Min; Park, Sungsoo; Park, Seong-Heum; Jung, Sung Woo; Choe, Jung Wan; Sul, Ji-Young; Jang, You Jin; Mok, Young-Jae; Kim, Jong-Han

    2017-04-01

    The aim of this study was to investigate the feasibility of sentinel node mapping using a fluorescent dye and visible light in patients with gastric cancer. Recently, fluorescent imaging technology offers improved visibility with the possibility of better sensitivity or accuracy in sentinel node mapping. Twenty patients with early gastric cancer, for whom laparoscopic distal gastrectomy with standard lymphadenectomy had been planned, were enrolled in this study. Before lymphadenectomy, the patients received a gastrofiberoscopic peritumoral injection of fluorescein solution. The sentinel basin was investigated via laparoscopic fluorescent imaging under blue light (wavelength of 440-490 nm) emitted from an LED curing light. The detection rate and lymph node status were analyzed in the enrolled patients. In addition, short-term clinical outcomes were also investigated. No hypersensitivity to the dye was identified in any enrolled patients. Sentinel nodes were detected in 19 of 20 enrolled patients (95.0%), and metastatic lymph nodes were found in 2 patients. The latter lymph nodes belonged to the sentinel basin of each patient. Meanwhile, 1 patient (5.0%) experienced a postoperative complication that was unrelated to sentinel node mapping. No mortality was recorded among enrolled cases. Sentinel node mapping with visible light fluorescence was a feasible method for visualizing sentinel nodes in patients with early gastric cancer. In addition, this method is advantageous in terms of visualizing the concrete relationship between the sentinel nodes and surrounding structures.

  14. An Optimal Balance between Efficiency and Safety of Urban Drainage Networks

    NASA Astrophysics Data System (ADS)

    Seo, Y.

    2014-12-01

    Urban drainage networks have been developed to promote the efficiency of a system in terms of drainage time so far. Typically, a drainage system is designed to drain water from developed areas promptly as much as possible during floods. In this regard, an artificial drainage system have been considered to be more efficient compared to river networks in nature. This study examined artificial drainage networks and the results indicate they can be less efficient in terms of network configuration compared with river networks, which is counter-intuitive. The case study of 20 catchments in Seoul, South Korea shows that they have wide range of efficiency in terms of network configuration and consequently, drainage time. This study also demonstrates that efficient drainage networks are more sensitive to spatial and temporal rainfall variation such as rainstorm movement. Peak flows increase more than two times greater in effective drainage networks compared with inefficient and highly sinuous drainage networks. Combining these results, this study implies that the layout of a drainage network is an important factor in terms of efficient drainage and also safety in urban catchments. Design of an optimal layout of the drainage network can be an alternative non-structural measures that mitigate potential risks and it is crucial for the sustainability of urban environments.

  15. Sentinel-5 Precursor: Preparing the first Copernicus Atmospheric Mission

    NASA Astrophysics Data System (ADS)

    Nett, Herbert; McMullan, Kevin; Ingmann, Paul; Fehr, Thorsten

    2015-11-01

    Sentinel-5 Precursor (S-5P) will be the first of a series of atmospheric missions to be launched within the European Commission's Copernicus (former GMES) Programme. With a planned launch in 2016 and a nominal lifetime of 7 years S-5P is expected to provide continuity in the availability of global atmospheric data products between its predecessor missions SCIAMACHY (Envisat) and OMI (AURA) and the future Sentinel-4 and -5 series. The latter will comprise payload instruments on board the operational satellites MTG-S (S-4, geostationary component) and MetOp Second Generation (S-5, polar orbiting component), the first units of which will be launched in the 2020-2021 timeframe.The S-5P satellite will carry a single payload, TROPOMI (TROPOspheric Monitoring Instrument) which is jointly developed by The Netherlands and ESA. Covering spectral channels in the UV, visible, near- and short-wave infrared it will measure various key species including tropospheric/stratospheric ozone, NO2, SO2, CO, CH4, CH2O as well as cloud and aerosol parameters.

  16. Novel Handheld Magnetometer Probe Based on Magnetic Tunnelling Junction Sensors for Intraoperative Sentinel Lymph Node Identification

    PubMed Central

    Cousins, A.; Balalis, G. L.; Thompson, S. K.; Forero Morales, D.; Mohtar, A.; Wedding, A. B.; Thierry, B.

    2015-01-01

    Using magnetic tunnelling junction sensors, a novel magnetometer probe for the identification of the sentinel lymph node using magnetic tracers was developed. Probe performance was characterised in vitro and validated in a preclinical swine model. Compared to conventional gamma probes, the magnetometer probe showed excellent spatial resolution of 4.0 mm, and the potential to detect as few as 5 μg of magnetic tracer. Due to the high sensitivity of the magnetometer, all first-tier nodes were identified in the preclinical experiments, and there were no instances of false positive or false negative detection. Furthermore, these preliminary data encourage the application of the magnetometer probe for use in more complex lymphatic environments, such as in gastrointestinal cancers, where the sentinel node is often in close proximity to other non-sentinel nodes, and high spatial resolution detection is required. PMID:26038833

  17. Lymphatic Mapping and Sentinel Lymph Node Biopsy in Women With Squamous Cell Carcinoma of the Vulva: A Gynecologic Oncology Group Study

    PubMed Central

    Levenback, Charles F.; Ali, Shamshad; Coleman, Robert L.; Gold, Michael A.; Fowler, Jeffrey M.; Judson, Patricia L.; Bell, Maria C.; De Geest, Koen; Spirtos, Nick M.; Potkul, Ronald K.; Leitao, Mario M.; Bakkum-Gamez, Jamie N.; Rossi, Emma C.; Lentz, Samuel S.; Burke, James J.; Van Le, Linda; Trimble, Cornelia L.

    2012-01-01

    Purpose To determine the safety of sentinel lymph node biopsy as a replacement for inguinal femoral lymphadenectomy in selected women with vulvar cancer. Patients and Methods Eligible women had squamous cell carcinoma, at least 1-mm invasion, and tumor size ≥ 2 cm and ≤ 6 cm. The primary tumor was limited to the vulva, and there were no groin lymph nodes that were clinically suggestive of cancer. All women underwent intraoperative lymphatic mapping, sentinel lymph node biopsy, and inguinal femoral lymphadenectomy. Histologic ultra staging of the sentinel lymph node was prescribed. Results In all, 452 women underwent the planned procedures, and 418 had at least one sentinel lymph node identified. There were 132 node-positive women, including 11 (8.3%) with false-negative nodes. Twenty-three percent of the true-positive patients were detected by immunohistochemical analysis of the sentinel lymph node. The sensitivity was 91.7% (90% lower confidence bound, 86.7%) and the false-negative predictive value (1-negative predictive value) was 3.7% (90% upper confidence bound, 6.1%). In women with tumor less than 4 cm, the false-negative predictive value was 2.0% (90% upper confidence bound, 4.5%). Conclusion Sentinel lymph node biopsy is a reasonable alternative to inguinal femoral lymphadenectomy in selected women with squamous cell carcinoma of the vulva. PMID:22753905

  18. Simultaneous mapping of pan and sentinel lymph nodes for real-time image-guided surgery.

    PubMed

    Ashitate, Yoshitomo; Hyun, Hoon; Kim, Soon Hee; Lee, Jeong Heon; Henary, Maged; Frangioni, John V; Choi, Hak Soo

    2014-01-01

    The resection of regional lymph nodes in the basin of a primary tumor is of paramount importance in surgical oncology. Although sentinel lymph node mapping is now the standard of care in breast cancer and melanoma, over 20% of patients require a completion lymphadenectomy. Yet, there is currently no technology available that can image all lymph nodes in the body in real time, or assess both the sentinel node and all nodes simultaneously. In this study, we report an optical fluorescence technology that is capable of simultaneous mapping of pan lymph nodes (PLNs) and sentinel lymph nodes (SLNs) in the same subject. We developed near-infrared fluorophores, which have fluorescence emission maxima either at 700 nm or at 800 nm. One was injected intravenously for identification of all regional lymph nodes in a basin, and the other was injected locally for identification of the SLN. Using the dual-channel FLARE intraoperative imaging system, we could identify and resect all PLNs and SLNs simultaneously. The technology we describe enables simultaneous, real-time visualization of both PLNs and SLNs in the same subject.

  19. Validating MODIS and Sentinel-2 NDVI Products at a Temperate Deciduous Forest Site Using Two Independent Ground-Based Sensors.

    PubMed

    Lange, Maximilian; Dechant, Benjamin; Rebmann, Corinna; Vohland, Michael; Cuntz, Matthias; Doktor, Daniel

    2017-08-11

    Quantifying the accuracy of remote sensing products is a timely endeavor given the rapid increase in Earth observation missions. A validation site for Sentinel-2 products was hence established in central Germany. Automatic multispectral and hyperspectral sensor systems were installed in parallel with an existing eddy covariance flux tower, providing spectral information of the vegetation present at high temporal resolution. Normalized Difference Vegetation Index (NDVI) values from ground-based hyperspectral and multispectral sensors were compared with NDVI products derived from Sentinel-2A and Moderate-resolution Imaging Spectroradiometer (MODIS). The influence of different spatial and temporal resolutions was assessed. High correlations and similar phenological patterns between in situ and satellite-based NDVI time series demonstrated the reliability of satellite-based phenological metrics. Sentinel-2-derived metrics showed better agreement with in situ measurements than MODIS-derived metrics. Dynamic filtering with the best index slope extraction algorithm was nevertheless beneficial for Sentinel-2 NDVI time series despite the availability of quality information from the atmospheric correction procedure.

  20. 24 CFR 3285.203 - Site Drainage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Purpose. Drainage must be provided to direct surface water away from the home to protect against erosion... home. (c) All drainage must be diverted away from the home and must slope a minimum of one-half inch per foot away from the foundation for the first ten feet. Where property lines, walls, slopes, or...

  1. Drainage hydraulics of permeable friction courses

    NASA Astrophysics Data System (ADS)

    Charbeneau, Randall J.; Barrett, Michael E.

    2008-04-01

    This paper describes solutions to the hydraulic equations that govern flow in permeable friction courses (PFC). PFC is a layer of porous asphalt approximately 50 mm thick that is placed as an overlay on top of an existing conventional concrete or asphalt road surface to help control splash and hydroplaning, reduce noise, and enhance quality of storm water runoff. The primary objective of this manuscript is to present an analytical system of equations that can be used in design and analysis of PFC systems. The primary assumptions used in this analysis are that the flow can be modeled as one-dimensional, steady state Darcy-type flow and that slopes are sufficiently small so that the Dupuit-Forchheimer assumptions apply. Solutions are derived for cases where storm water drainage is confined to the PFC bed and for conditions where the PFC drainage capacity is exceeded and ponded sheet flow occurs across the pavement surface. The mathematical solutions provide the drainage characteristics (depth and residence time) as a function of rainfall intensity, PFC hydraulic conductivity, pavement slope, and maximum drainage path length.

  2. Opportunities for Reducing Nitrate Export from Drainage Systems through In-field Nitrogen Management, Cropping Practices, and Drainage Design and Management

    NASA Astrophysics Data System (ADS)

    Helmers, M.; Zhou, X.; Qi, Z.; Christianson, R.; Pederson, C.

    2011-12-01

    Subsurface drainage systems are widely used throughout the upper Midwest corn-belt. While the use of these drainage systems has greatly increased crop production, they have also increased nitrate-nitrogen export to downstream waterbodies. As a result, there is a need to evaluate and implement management practices that have potential to reduce nitrate-nitrogen loss. A twenty year study in Iowa has shown that major factors in nitrate-nitrogen loss are land use and hydrology. Studies from north-central Iowa have also indicated that nitrogen application rate and to a lesser degree timing of nitrogen application important factors for nitrate-nitrogen loss. A four-year (2007-2010) drainage management study in southeast Iowa indicates that shallow and controlled drainage systems have potential to decrease subsurface drainage and thereby reduce nitrate-N loss from drain water but the level of implementation of controlled drainage may be limited by topography. Cropping practices through cover crops or perennial biomass crops have also been documented to have potential to reduce downstream nitrate-nitrogen export but the level of implementation may be limited by management and economic considerations. To achieve reduction goals for protection of local and regional water quality will require a combination of these practices at the landscape scale.

  3. From ASCAT to Sentinel-1: Soil Moisture Monitoring using European C-Band Radars

    NASA Astrophysics Data System (ADS)

    Wagner, Wolfgang; Bauer-Marschallinger, Bernhard; Hochstöger, Simon

    2016-04-01

    The Advanced Scatterometer (ASCAT) is a C-Band radar instrument flown on board of the series of three METOP satellites. Albeit not operating in one of the more favorable longer wavelength ranges (S, L or P-band) as the dedicated Soil Moisture and Ocean Salinity (SMOS) and Soil Moisture Active Passive (SMAP) missions, it is one of main microwave sensors used for monitoring of soil moisture on a global scale. Its attractiveness for soil moisture monitoring applications stems from its operational status, high radiometric accuracy and stability, short revisit time, multiple viewing directions and long heritage (Wagner et al. 2013). From an application perspective, its main limitation is its spatial resolution of about 25 km, which does not allow resolving soil moisture patterns driven by smaller-scale hydrometeorological processes (e.g. convective precipitation, runoff patterns, etc.) that are themselves related to highly variable land surface characteristics (soil characteristics, topography, vegetation cover, etc.). Fortunately, the technique of aperture synthesis allows to significantly improve the spatial resolution of spaceborne radar instruments up to the meter scale. Yet, past Synthetic Aperture Radar (SAR) missions had not yet been designed to achieve a short revisit time required for soil moisture monitoring. This has only changed recently with the development and launch of SMAP (Entekhabi et al. 2010) and Sentinel-1 (Hornacek et al. 2012). Unfortunately, the SMAP radar failed only after a few months of operations, which leaves Sentinel-1 as the only currently operational SAR mission capable of delivering high-resolution radar observations with a revisit time of about three days for Europe, about weekly for most crop growing regions worldwide, and about bi-weekly to monthly over the rest of the land surface area. Like ASCAT, Sentinel-1 acquires C-band backscatter data in VV polarization over land. Therefore, for the interpretation of both ASCAT and Sentinel-1

  4. Agricultural drainage pipe detection using ground penetrating radar: Effects of antenna orientation relative to drainage pipe directional trend

    USDA-ARS?s Scientific Manuscript database

    Locating buried agricultural drainage pipes is a difficult problem confronting farmers and land improvement contractors, especially in the Midwest U.S., where the removal of excess soil water using subsurface drainage systems is a common farm practice. Enhancing the efficiency of soil water removal ...

  5. Modeling of subglacial hydrological development following rapid supraglacial lake drainage.

    PubMed

    Dow, C F; Kulessa, B; Rutt, I C; Tsai, V C; Pimentel, S; Doyle, S H; van As, D; Lindbäck, K; Pettersson, R; Jones, G A; Hubbard, A

    2015-06-01

    The rapid drainage of supraglacial lakes injects substantial volumes of water to the bed of the Greenland ice sheet over short timescales. The effect of these water pulses on the development of basal hydrological systems is largely unknown. To address this, we develop a lake drainage model incorporating both (1) a subglacial radial flux element driven by elastic hydraulic jacking and (2) downstream drainage through a linked channelized and distributed system. Here we present the model and examine whether substantial, efficient subglacial channels can form during or following lake drainage events and their effect on the water pressure in the surrounding distributed system. We force the model with field data from a lake drainage site, 70 km from the terminus of Russell Glacier in West Greenland. The model outputs suggest that efficient subglacial channels do not readily form in the vicinity of the lake during rapid drainage and instead water is evacuated primarily by a transient turbulent sheet and the distributed system. Following lake drainage, channels grow but are not large enough to reduce the water pressure in the surrounding distributed system, unless preexisting channels are present throughout the domain. Our results have implications for the analysis of subglacial hydrological systems in regions where rapid lake drainage provides the primary mechanism for surface-to-bed connections. Model for subglacial hydrological analysis of rapid lake drainage eventsLimited subglacial channel growth during and following rapid lake drainagePersistence of distributed drainage in inland areas where channel growth is limited.

  6. Modeling of subglacial hydrological development following rapid supraglacial lake drainage

    PubMed Central

    Dow, C F; Kulessa, B; Rutt, I C; Tsai, V C; Pimentel, S; Doyle, S H; van As, D; Lindbäck, K; Pettersson, R; Jones, G A; Hubbard, A

    2015-01-01

    The rapid drainage of supraglacial lakes injects substantial volumes of water to the bed of the Greenland ice sheet over short timescales. The effect of these water pulses on the development of basal hydrological systems is largely unknown. To address this, we develop a lake drainage model incorporating both (1) a subglacial radial flux element driven by elastic hydraulic jacking and (2) downstream drainage through a linked channelized and distributed system. Here we present the model and examine whether substantial, efficient subglacial channels can form during or following lake drainage events and their effect on the water pressure in the surrounding distributed system. We force the model with field data from a lake drainage site, 70 km from the terminus of Russell Glacier in West Greenland. The model outputs suggest that efficient subglacial channels do not readily form in the vicinity of the lake during rapid drainage and instead water is evacuated primarily by a transient turbulent sheet and the distributed system. Following lake drainage, channels grow but are not large enough to reduce the water pressure in the surrounding distributed system, unless preexisting channels are present throughout the domain. Our results have implications for the analysis of subglacial hydrological systems in regions where rapid lake drainage provides the primary mechanism for surface-to-bed connections. Key Points Model for subglacial hydrological analysis of rapid lake drainage events Limited subglacial channel growth during and following rapid lake drainage Persistence of distributed drainage in inland areas where channel growth is limited PMID:26640746

  7. Assessment of Sentinel Node Biopsies With Full-Field Optical Coherence Tomography.

    PubMed

    Grieve, Kate; Mouslim, Karima; Assayag, Osnath; Dalimier, Eugénie; Harms, Fabrice; Bruhat, Alexis; Boccara, Claude; Antoine, Martine

    2016-04-01

    Current techniques for the intraoperative analysis of sentinel lymph nodes during breast cancer surgery present drawbacks such as time and tissue consumption. Full-field optical coherence tomography is a novel noninvasive, high-resolution, fast imaging technique. This study investigated the use of full-field optical coherence tomography as an alternative technique for the intraoperative analysis of sentinel lymph nodes. Seventy-one axillary lymph nodes from 38 patients at Tenon Hospital were imaged minutes after excision with full-field optical coherence tomography in the pathology laboratory, before being handled for histological analysis. A pathologist performed a blind diagnosis (benign/malignant), based on the full-field optical coherence tomography images alone, which resulted in a sensitivity of 92% and a specificity of 83% (n = 65 samples). Regular feedback was given during the blind diagnosis, with thorough analysis of the images, such that features of normal and suspect nodes were identified in the images and compared with histology. A nonmedically trained imaging expert also performed a blind diagnosis aided by the reading criteria defined by the pathologist, which resulted in 85% sensitivity and 90% specificity (n = 71 samples). The number of false positives of the pathologist was reduced by 3 in a second blind reading a few months later. These results indicate that following adequate training, full-field optical coherence tomography can be an effective noninvasive diagnostic tool for extemporaneous sentinel node biopsy qualification. © The Author(s) 2015.

  8. TROPOMI on ESA's Sentinel 5p ready for launch and use

    NASA Astrophysics Data System (ADS)

    de Vries, Johan; Voors, Robert; Ording, Barend; Dingjan, Jos; Veefkind, Pepijn; Ludewig, Antje; Kleipool, Quintus; Hoogeveen, Ruud; Aben, Ilse

    2016-08-01

    TROPOMI is the single instrument on ESA's Sentinel 5 precursor satellite to be launched in October 2016. TROPOMI will measure the atmospheric constituents absorbing in the UV-SWIR wavelength range, being O3, NO2, SO2, CH4, CO, CH2O, and aerosol properties. TROPOMI is a sun back-scatter instrument in the line of SCIAMACHY and OMI with 4 spectrometer bands and a spectral resolution of 0.25 - 0.5 nm. Following the earlier sensors, firstly the spatial resolution is improved by a factor 6 (OMI) to 7 x 7 km2 and at the same time the sensitivity by an order of magnitude. The paper discusses the instrument performances as acquired from on-ground performance / calibration measurements. For the calibration an extremely condensed measurement campaign of 4 months 24/7 measurements was performed with virtually no slack and still gathering all of the data necessary from on-ground measurements. Given the fact that the trace gas signals and their variation in the measured spectra can be quite small, calibration is crucial to get accurate results and this illustrates that TROPOMI is a highly success driven and efficient programme. TROPOMI / Sentinel-5p bridges the data streams from on one hand OMI and SCIAMACHY and on the other hand the future Sentinel-5. It is the first of a series of satellites from the Copernicus programme devoted to air quality and will soon be ready for use.

  9. Axillary web syndrome following sentinel node biopsy for breast cancer.

    PubMed

    Nieves Maldonado, S M; Pubul Núñez, V; Argibay Vázquez, S; Macías Cortiñas, M; Ruibal Morell, Á

    2016-01-01

    A 49 year-old woman diagnosed with infiltrating lobular breast carcinoma, underwent a right mastectomy and sentinel node biopsy (SLNB). The resected sentinel lymph nodes were negative for malignancy, with an axillary lymphadenectomy not being performed. In the early post-operative period, the patient reported an axillary skin tension sensation, associated with a painful palpable cord. These are typical manifestations of axillary web syndrome (AWS), a poorly known axillary surgery complication, from both invasive and conservative interventions. By presenting this case we want to focus the attention on a pathological condition, for which its incidence may be underestimated by not including it in SLNB studies. It is important for nuclear medicine physicians to be aware of AWS as a more common complication than infection, seroma, or lymphoedema, and to discuss this possible event with the patient who is consenting to the procedure. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  10. Measuring Surface Subsidence in Wuhan, China with SENTINEL-1 Data Using Psinsar

    NASA Astrophysics Data System (ADS)

    Benattou, M. M.; Balz, T.; Liao, M.

    2018-04-01

    We use the potential of Sentinel-1 for urban subsidence monitoring. A case study was conducted in Wuhan using Sentinel-1A images acquired from 22nd June 2015 to the 24th of April 2017 acquired from an ascending orbit. Our results using PSInSAR are compared to a recent study using SBAS. Moreover, in another experiment, only more recent data, containing 18 images from the 7th of March 2017 to the 14th of March 2018, have been processed in order to analysis changes in the subsidence behavior over the study area. In addition to that, the proposed method (PSInSAR) was used to measure the water height in the east lake using metallic objects as stable PS points.

  11. Sentinel 2: implementation of the means and methods for the CAL/VAL commissioning phase

    NASA Astrophysics Data System (ADS)

    Trémas, Thierry L.; Déchoz, Cécile; Lacherade, Sophie; Nosavan, Julien; Petrucci, Beatrice; Martimort, P.; Isola, Claudia

    2013-10-01

    In partnership with the European Commission and in the frame of the Copernicus program, the European Space Agency (ESA) is developing the Sentinel-2 optical imaging mission devoted to the operational monitoring of land and coastal areas. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. Sentinel-2 will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). The first satellite is planned to be launched in late 2014. In this context, the Centre National d'Etudes Spatiales (CNES) supports ESA to insure the cal/val commissioning phase. This paper provides first, an overview of the Sentinel-2 system and the image products delivered by the ground processing. Then the paper will present the ground segment, presently under preparation at CNES, and the various devices that compose it : the GPP in charge of producing the level 1 files, the "radiometric unit" that processes sensitivity parameters, the "geometric unit" in charge of fitting the images on a reference map, MACCS that will produce Level 2A files (computing reflectances at the Bottom of Atmosphere) and the TEC-S2 that will coordinate all the previous software and drive a database in which will be gather the incoming Level 0 files and the processed Level 1 files.

  12. Omitting chest tube drainage after thoracoscopic major lung resection.

    PubMed

    Ueda, Kazuhiro; Hayashi, Masataro; Tanaka, Toshiki; Hamano, Kimikazu

    2013-08-01

    Absorbable mesh and fibrin glue applied to prevent alveolar air leakage contribute to reducing the length of chest tube drainage, length of hospitalization and the rate of pulmonary complications. This study investigated the feasibility of omitting chest tube drainage in selected patients undergoing thoracoscopic major lung resection. Intraoperative air leakages were sealed with fibrin glue and absorbable mesh in patients undergoing thoracoscopic major lung resection. The chest tube was removed just after tracheal extubation if no air leakages were detected in a suction-induced air leakage test, which is an original technique to confirm pneumostasis. Patients with bleeding tendency or extensive thoracic adhesions were excluded. Chest tube drainage was omitted in 29 (58%) of 50 eligible patients and was used in 21 (42%) on the basis of suction-induced air leakage test results. Male gender and compromised pulmonary function were significantly associated with the failure to omit chest tube drainage (both, P < 0.05). Regardless of omitting the chest tube drainage, there were no adverse events during hospitalization, such as subcutaneous emphysema, pneumothorax, pleural effusion or haemothorax, requiring subsequent drainage. Furthermore, there was no prolonged air leakage in any patients: The mean length of chest tube drainage was only 0.9 days. Omitting the chest tube drainage was associated with reduced pain on the day of the operation (P = 0.046). The refined strategy for pneumostasis allowed the omission of chest tube drainage in the majority of patients undergoing thoracoscopic major lung resection without increasing the risk of adverse events, which may contribute to a fast-track surgery.

  13. An Introduction to ESERO-UK, the UK Space Education Office

    ERIC Educational Resources Information Center

    Clements, Allan; Mather, Edward

    2012-01-01

    This article introduces the UK branch of the European Space Education Resource Office (ESERO-UK), also known as the UK Space Education Office. It is a teaching project designed to use space to enthuse primary and secondary students to study science, technology, engineering and mathematics (STEM) subjects. The office is funded by the European Space…

  14. Characterising and improving the performance of the Sentinel-3 SRAL altimeter: A Report from SCOOP, SHAPE & SPICE Projects

    NASA Astrophysics Data System (ADS)

    Restano, Marco; Ambrózio, Américo; Cotton, David; Scoop Team; Fabry, Pierre; Shape Team; McMillan, Malcolm; Spice Team; Benveniste, Jérôme

    2017-04-01

    Under the ESA Scientific Exploitation of Operational Missions (SEOM) Programme, 3 Projects are currently underway to accurately characterise and improve the performance of the Sentinel-3 SRAL SAR mode altimeter. They are: 1) SCOOP (SAR Altimetry Coastal & Open Ocean Performance Exploitation and Roadmap Study) for Coastal and Open Ocean; 2) SHAPE (Sentinel-3 Hydrologic Altimetry PrototypE) for Inland Water; 3) SPICE (Sentinel-3 Performance improvement for ICE sheets) for Ice Sheets. As projects started before the launch of Sentinel-3 (a full SAR mission), calibrated Cryosat-2 data have been used as input to a processor replicating the Sentinel-3 baseline processing. For the SCOOP project, a first test dataset has been released to end users including data from 10 regions of interest. The successful SAMOSA retracker, adopted in the previous CP4O Project (CryoSat Plus for Oceans), has been readapted to re-track Sentinel-3 waveforms. An improved version of SAMOSA will be released at the end of the project. The SHAPE project is working towards the design and assessment of alternative/innovative techniques not implemented in the Sentinel-3 ground segment (performing no Inland Water dedicated processing). Both rivers and lakes will be studied. Amazon, Brahmaputra and Danube have been selected as rivers, whereas Titicaca and Vanern have been chosen as lakes. The study will include the assimilation of output products into hydrological models for all regions of interest. A final dataset will be provided to end users. The SPICE project is addressing four high level objectives: 1) Assess and improve the Delay-Doppler altimeter processing for ice sheets. 2) Assess and develop SAR waveform retrackers for ice sheets. 3) Evaluate the performance of SAR altimetry relative to conventional pulse limited altimetry. 4) Assess the impact on SAR altimeter measurements of radar wave interaction with the snowpack. Dataset used for validation include ICESat and IceBridge products. Vostok

  15. Effect of viscosity on tear drainage and ocular residence time.

    PubMed

    Zhu, Heng; Chauhan, Anuj

    2008-08-01

    An increase in residence time of dry eye medications including artificial tears will likely enhance therapeutic benefits. The drainage rates and the residence time of eye drops depend on the viscosity of the instilled fluids. However, a quantitative understanding of the dependence of drainage rates and the residence time on viscosity is lacking. The current study aims to develop a mathematical model for the drainage of Newtonian fluids and also for power-law non-Newtonian fluids of different viscosities. This study is an extension of our previous study on the mathematical model of tear drainage. The tear drainage model is modified to describe the drainage of Newtonian fluids with viscosities higher than the tear viscosity and power-law non-Newtonian fluids with rheological parameters obtained from fitting experimental data in literature. The drainage rate through canaliculi was derived from the modified drainage model and was incorporated into a tear mass balance to calculate the transients of total solute quantity in ocular fluids and the bioavailability of instilled drugs. For Newtonian fluids, increasing the viscosity does not affect the drainage rate unless the viscosity exceeds a critical value of about 4.4 cp. The viscosity has a maximum impact on drainage rate around a value of about 100 cp. The trends are similar for shear thinning power law fluids. The transients of total solute quantity, and the residence time agrees at least qualitatively with experimental studies. A mathematical model has been developed for the drainage of Newtonian fluids and power-law fluids through canaliculi. The model can quantitatively explain different experimental observations on the effect of viscosity on the residence of instilled fluids on the ocular surface. The current study is helpful for understanding the mechanism of fluid drainage from the ocular surface and for improving the design of dry eye treatments.

  16. Forest drainage

    Treesearch

    R.W. Skaggs; S. Tian; G.M. Chescheir; Devendra Amatya; M.A. Youssef

    2016-01-01

    Most of the world's 4030 million ha of forested lands are situated on hilly, mountainous or well-drained upland landscapes where improved drainage is not needed. However, there are millions of hectares of poorly drained forested lands where excessively wet soil conditions limit tree growth and access for harvesting and other management activities. Improved or...

  17. A GPR agricultural drainage pipe detection case study: Effects of antenna orientation relative to drainage pipe directional trend

    USDA-ARS?s Scientific Manuscript database

    Locating buried drainage pipes is a difficult task confronting farmers and land improvement contractors, especially in the Midwest U.S., where the removal of excess soil water using subsurface drainage systems is a common farm practice. Enhancing the efficiency of soil water removal on land containi...

  18. Preoperative biliary drainage in hilar cholangiocarcinoma: When and how?

    PubMed Central

    Paik, Woo Hyun; Loganathan, Nerenthran; Hwang, Jin-Hyeok

    2014-01-01

    Hilar cholangiocarcinoma is a tumor of the extrahepatic bile duct involving the left main hepatic duct, the right main hepatic duct, or their confluence. Biliary drainage in hilar cholangiocarcinoma is sometimes clinically challenging because of complexities associated with the level of biliary obstruction. This may result in some adverse events, especially acute cholangitis. Hence the decision on the indication and methods of biliary drainage in patients with hilar cholangiocarcinoma should be carefully evaluated. This review focuses on the optimal method and duration of preoperative biliary drainage (PBD) in resectable hilar cholangiocarcinoma. Under certain special indications such as right lobectomy for Bismuth type IIIA or IV hilar cholangiocarcinoma, or preoperative portal vein embolization with chemoradiation therapy, PBD should be strongly recommended. Generally, selective biliary drainage is enough before surgery, however, in the cases of development of cholangitis after unilateral drainage or slow resolving hyperbilirubinemia, total biliary drainage may be considered. Although the optimal preoperative bilirubin level is still a matter of debate, the shortest possible duration of PBD is recommended. Endoscopic nasobiliary drainage seems to be the most appropriate method of PBD in terms of minimizing the risks of tract seeding and inflammatory reactions. PMID:24634710

  19. Photo-guided sentinel node mapping in breast cancer using marker-free photo-gamma fusion lymphoscintigraphy.

    PubMed

    Lee, Eun Seong; Chun, In Kook; Ha, Seunggyun; Yoon, Hai-Jeon; Jung, So-Youn; Lee, Seeyoun; Kim, Seok Won; Lee, Eun Sook; Kim, Taeyoon; Kim, Kwang Gi; Lee, Byung Il; Kim, Tae Sung; Kim, Seok-Ki

    2013-03-01

    Photo-gamma fusion lymphoscintigraphy (PGFLS) was developed by overlying a conventional planar gamma image on a photograph for the guidance of sentinel node biopsy. The feasibility and accuracy of PGFLS was assessed in breast cancer patients. A digital camera and a gamma camera were coordinated to obtain photograph and gamma images from the same angle. Using the distance to the object and calibration acquisition with a flat phantom and radioactive markers, PGFLS was performed both in phantom and in patients without fiducial markers. Marker-free PGFLS was verified using flat phantom, anthropomorphic phantom with markers simulating sentinel nodes and breast cancer patients. In addition, the depth of the radioactive marker or sentinel node was calculated using two gamma images taken at right angles. The feasibility and accuracy of PGFLS were assessed in terms of mismatch errors of co-registration and depth with reference to the data from SPECT/CT. The mismatch error was less than 6 mm in the flat phantom image at a distance from 50 to 62 cm without misalignment. In the anthropomorphic phantom study, co-registration error was 0.42 ± 0.29 cm; depth error was 0.51 ± 0.37 cm, which was well correlated with the reference value on SPECT/CT (x scale: R(2) = 0.99, p < 0.01; y scale: R(2) = 0.99, p < 0.01; depth: R(2) = 0.99, p < 0.01). In ten patients with breast cancer referred for lympho-SPECT/CT, PGFSL enabled photo-guided sentinel lymph node mapping with acceptable accuracy (co-registration error, 0.47 ± 0.24 cm; depth error, 1.20 ±0.41 cm). The results from PGFSL showed close correlation with those from SPECT/CT (x scale: R(2) = 0.99, p < 0.01; y scale: R(2) = 0.98, p < 0.01; depth: R(2) = 0.77, p < 0.01). The novel and convenient PGFLS technique is clinically feasible, showing acceptable accuracy and providing additional visual and quantitative information for sentinel lymph node mapping. This

  20. Ear drainage culture

    MedlinePlus

    ... needed. Your health care provider will use a cotton swab to collect the sample from inside the ... Using a cotton swab to take a sample of drainage from the outer ear is not painful. However, ear pain may ...

  1. Vegetation Mapping in a Dryland Ecosystem Using Multi-temporal Sentinel-2 Imagery and Ensemble Learning

    NASA Astrophysics Data System (ADS)

    Enterkine, J.; Spaete, L.; Glenn, N. F.; Gallagher, M.

    2017-12-01

    Remote sensing and mapping of dryland ecosystem vegetation is notably problematic due to the low canopy cover and fugacious growing seasons. Recent improvements in available satellite imagery and machine learning techniques have enabled enhanced approaches to mapping and monitoring vegetation across dryland ecosystems. The Sentinel-2 satellites (launched June 2015 and March 2017) of ESA's Copernicus Programme offer promising developments from existing multispectral satellite systems such as Landsat. Freely-available, Sentinel-2 imagery offers a five-day revisit frequency, thirteen spectral bands (in the visible, near infrared, and shortwave infrared), and high spatial resolution (from 10m to 60m). Three narrow spectral bands located between the visible and the near infrared are designed to observe changes in photosynthesis. The high temporal, spatial, and spectral resolution of this imagery makes it ideal for monitoring vegetation in dryland ecosystems. In this study, we calculated a large number of vegetation and spectral indices from Sentinel-2 imagery spanning a growing season. This data was leveraged with robust field data of canopy cover at precise geolocations. We then used a Random Forests ensemble learning model to identify the most predictive variables for each landcover class, which were then used to impute landcover over the study area. The resulting vegetation map product will be used by land managers, and the mapping approaches will serve as a basis for future remote sensing projects using Sentinel-2 imagery and machine learning.

  2. Riparian spiders as sentinels of PCB contamination across heterogeneous aquatic ecosystems

    EPA Science Inventory

    Riparian spiders are being used increasingly to track spatial patterns of contaminants in and fluxing from aquatic ecosystems. However, our understanding of the circumstances under which spiders are effective sentinels of aquatic pollution is limited. The present study tests the ...

  3. Agricultural Drainage Management Systems Task Force (ADMSTF)

    USDA-ARS?s Scientific Manuscript database

    The Agricultural Drainage Management Systems (ADMS) Task Force was initiated during a Charter meeting in the fall of 2002 by dedicated professional employees of Federal, State, and Local Government Agencies and Universities. The Agricultural Drainage Management (ADM) Coalition was established in 200...

  4. The construction technology of Chinese ancient city drainage facilities

    NASA Astrophysics Data System (ADS)

    Hequn, Li; Yufengyun

    2018-03-01

    In ancient china, according to the local natural environment, a variety of drainage facilities were built in order to excrete rainwater, domestic sewage, production wastewater and so on. These drainage facilities were mainly made of pottery, bricks, wood, stone, etc. For example, ceramic water pipelines, buried in the ground, connect together one by one, and there was a slight drop from one end to the other in favor of drainage. These measures can also be used for reference in today’s urban drainage and flood control.

  5. Drainage divides, Massachusetts; Blackstone and Thames River basins

    USGS Publications Warehouse

    Krejmas, Bruce E.; Wandle, S. William

    1982-01-01

    Drainage boundaries for selected subbasins of the Blackstone and Thames River basins in eastern Hampden, eastern Hampshire, western Norfolk, southern Middlesex, and southern Worcester Counties, Massachusetts, are delineated on 12 topographic quadrangle maps at a scale of 1:24,000. Drainage basins are shown for all U.S. Geological Survey data-collection sites and for mouths of major rivers. Drainage basins are shown for the outlets of lakes or ponds and for streams where the drainage area is greater than 3 square miles. Successive sites along watercourses are indicated where the intervening area is at least 6 miles on tributary streams or 15 square miles along the Blackstone River, French River, or Quinebaug River. (USGS)

  6. Comparative evaluation of the efficiency of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap for the surveillance of vector mosquitoes.

    PubMed

    Li, Yiji; Su, Xinghua; Zhou, Guofa; Zhang, Hong; Puthiyakunnon, Santhosh; Shuai, Shufen; Cai, Songwu; Gu, Jinbao; Zhou, Xiaohong; Yan, Guiyun; Chen, Xiao-Guang

    2016-08-12

    The surveillance of vector mosquitoes is important for the control of mosquito-borne diseases. To identify a suitable surveillance tool for the adult dengue vector Aedes albopictus, the efficacy of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap (MOT) on the capture of vector mosquitoes were comparatively evaluated in this study. The capture efficiencies of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap for common vector mosquitoes were tested in a laboratory setting, through the release-recapture method, and at two field sites of Guangzhou, China from June 2013 to May 2014. The captured mosquitoes were counted, species identified and compared among the three traps on the basis of species. In the release-recapture experiments in a laboratory setting, the BG-Sentinel trap caught significantly more Aedes albopictus and Culex quinquefasciatus than the CDC light trap and Mosquito-ovitrap, except for Anopheles sinensis. The BG-Sentinel trap had a higher efficacy in capturing female rather than male Ae. albopictus and Cx. quinquefasciatus, but the capture in CDC light traps displayed no significant differences. In the field trial, BG-Sentinel traps collected more Aedes albopictus than CDC light traps and MOTs collected in both urban and suburban areas. The BG-Sentinel trap was more sensitive for monitoring the population density of Aedes albopictus than the CDC light trap and MOT during the peak months of the year 2013. However, on an average, CDC light traps captured significantly more Cx. quinquefasciatus than BG-Sentinel traps. The population dynamics of Cx. quinquefasciatus displayed a significant seasonal variation, with the lowest numbers in the middle of the year. This study indicates that the BG-Sentinel trap is more effective than the commonly used CDC light trap and MOT in sampling adult Aedes albopictus and Culex quinquefasciatus. We recommend its use in the surveillance of dengue vector mosquitoes in China.

  7. Environmental controls on drainage behavior of an ephemeral stream

    USGS Publications Warehouse

    Blasch, K.W.; Ferré, T.P.A.; Vrugt, J.A.

    2010-01-01

    Streambed drainage was measured at the cessation of 26 ephemeral streamflow events in Rillito Creek, Tucson, Arizona from August 2000 to June 2002 using buried time domain reflectometry (TDR) probes. An unusual drainage response was identified, which was characterized by sharp drainage from saturation to near field capacity at each depth with an increased delay between depths. We simulated the drainage response using a variably saturated numerical flow model representing a two-layer system with a high permeability layer overlying a lower permeability layer. Both the observed data and the numerical simulation show a strong correlation between the drainage velocity and the temperature of the stream water. A linear combination of temperature and the no-flow period preceding flow explained about 90% of the measured variations in drainage velocity. Evaluation of this correlative relationship with the one-dimensional numerical flow model showed that the observed temperature fluctuations could not reproduce the magnitude of variation in the observed drainage velocity. Instead, the model results indicated that flow duration exerts the most control on drainage velocity, with the drainage velocity decreasing nonlinearly with increasing flow duration. These findings suggest flow duration is a primary control of water availability for plant uptake in near surface sediments of an ephemeral stream, an important finding for estimating the ecological risk of natural or engineered changes to streamflow patterns. Correlative analyses of soil moisture data, although easy and widely used, can result in erroneous conclusions of hydrologic cause—effect relationships, and demonstrating the need for joint physically-based numerical modeling and data synthesis for hypothesis testing to support quantitative risk analysis.

  8. Fractal Analysis of Drainage Basins on Mars

    NASA Technical Reports Server (NTRS)

    Stepinski, T. F.; Marinova, M. M.; McGovern, P. J.; Clifford, S. M.

    2002-01-01

    We used statistical properties of drainage networks on Mars as a measure of martian landscape morphology and an indicator of landscape evolution processes. We utilize the Mars Orbiter Laser Altimeter (MOLA) data to construct digital elevation maps (DEMs) of several, mostly ancient, martian terrains. Drainage basins and channel networks are computationally extracted from DEMs and their structures are analyzed and compared to drainage networks extracted from terrestrial and lunar DEMs. We show that martian networks are self-affine statistical fractals with planar properties similar to terrestrial networks, but vertical properties similar to lunar networks. The uniformity of martian drainage density is between those for terrestrial and lunar landscapes. Our results are consistent with the roughening of ancient martian terrains by combination of rainfall-fed erosion and impacts, although roughening by other fluvial processes cannot be excluded. The notion of sustained rainfall in recent Mars history is inconsistent with our findings.

  9. Application of BIM Technology in Building Water Supply and Drainage Design

    NASA Astrophysics Data System (ADS)

    Wei, Tianyun; Chen, Guiqing; Wang, Junde

    2017-12-01

    Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.

  10. Completion Dissection or Observation for Sentinel-Node Metastasis in Melanoma.

    PubMed

    Faries, Mark B; Thompson, John F; Cochran, Alistair J; Andtbacka, Robert H; Mozzillo, Nicola; Zager, Jonathan S; Jahkola, Tiina; Bowles, Tawnya L; Testori, Alessandro; Beitsch, Peter D; Hoekstra, Harald J; Moncrieff, Marc; Ingvar, Christian; Wouters, Michel W J M; Sabel, Michael S; Levine, Edward A; Agnese, Doreen; Henderson, Michael; Dummer, Reinhard; Rossi, Carlo R; Neves, Rogerio I; Trocha, Steven D; Wright, Frances; Byrd, David R; Matter, Maurice; Hsueh, Eddy; MacKenzie-Ross, Alastair; Johnson, Douglas B; Terheyden, Patrick; Berger, Adam C; Huston, Tara L; Wayne, Jeffrey D; Smithers, B Mark; Neuman, Heather B; Schneebaum, Schlomo; Gershenwald, Jeffrey E; Ariyan, Charlotte E; Desai, Darius C; Jacobs, Lisa; McMasters, Kelly M; Gesierich, Anja; Hersey, Peter; Bines, Steven D; Kane, John M; Barth, Richard J; McKinnon, Gregory; Farma, Jeffrey M; Schultz, Erwin; Vidal-Sicart, Sergi; Hoefer, Richard A; Lewis, James M; Scheri, Randall; Kelley, Mark C; Nieweg, Omgo E; Noyes, R Dirk; Hoon, Dave S B; Wang, He-Jing; Elashoff, David A; Elashoff, Robert M

    2017-06-08

    Sentinel-lymph-node biopsy is associated with increased melanoma-specific survival (i.e., survival until death from melanoma) among patients with node-positive intermediate-thickness melanomas (1.2 to 3.5 mm). The value of completion lymph-node dissection for patients with sentinel-node metastases is not clear. In an international trial, we randomly assigned patients with sentinel-node metastases detected by means of standard pathological assessment or a multimarker molecular assay to immediate completion lymph-node dissection (dissection group) or nodal observation with ultrasonography (observation group). The primary end point was melanoma-specific survival. Secondary end points included disease-free survival and the cumulative rate of nonsentinel-node metastasis. Immediate completion lymph-node dissection was not associated with increased melanoma-specific survival among 1934 patients with data that could be evaluated in an intention-to-treat analysis or among 1755 patients in the per-protocol analysis. In the per-protocol analysis, the mean (±SE) 3-year rate of melanoma-specific survival was similar in the dissection group and the observation group (86±1.3% and 86±1.2%, respectively; P=0.42 by the log-rank test) at a median follow-up of 43 months. The rate of disease-free survival was slightly higher in the dissection group than in the observation group (68±1.7% and 63±1.7%, respectively; P=0.05 by the log-rank test) at 3 years, based on an increased rate of disease control in the regional nodes at 3 years (92±1.0% vs. 77±1.5%; P<0.001 by the log-rank test); these results must be interpreted with caution. Nonsentinel-node metastases, identified in 11.5% of the patients in the dissection group, were a strong, independent prognostic factor for recurrence (hazard ratio, 1.78; P=0.005). Lymphedema was observed in 24.1% of the patients in the dissection group and in 6.3% of those in the observation group. Immediate completion lymph-node dissection increased

  11. 46 CFR 171.155 - Drainage of an open boat.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Drainage of an open boat. 171.155 Section 171.155 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.155 Drainage of an open boat. The...

  12. 46 CFR 171.155 - Drainage of an open boat.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Drainage of an open boat. 171.155 Section 171.155 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.155 Drainage of an open boat. The...

  13. 46 CFR 171.155 - Drainage of an open boat.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Drainage of an open boat. 171.155 Section 171.155 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.155 Drainage of an open boat. The...

  14. 46 CFR 171.155 - Drainage of an open boat.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Drainage of an open boat. 171.155 Section 171.155 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.155 Drainage of an open boat. The...

  15. 46 CFR 171.155 - Drainage of an open boat.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Drainage of an open boat. 171.155 Section 171.155 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS Drainage of Weather Decks § 171.155 Drainage of an open boat. The...

  16. Assessment of Classification Accuracies of SENTINEL-2 and LANDSAT-8 Data for Land Cover / Use Mapping

    NASA Astrophysics Data System (ADS)

    Hale Topaloğlu, Raziye; Sertel, Elif; Musaoğlu, Nebiye

    2016-06-01

    This study aims to compare classification accuracies of land cover/use maps created from Sentinel-2 and Landsat-8 data. Istanbul metropolitan city of Turkey, with a population of around 14 million, having different landscape characteristics was selected as study area. Water, forest, agricultural areas, grasslands, transport network, urban, airport- industrial units and barren land- mine land cover/use classes adapted from CORINE nomenclature were used as main land cover/use classes to identify. To fulfil the aims of this research, recently acquired dated 08/02/2016 Sentinel-2 and dated 22/02/2016 Landsat-8 images of Istanbul were obtained and image pre-processing steps like atmospheric and geometric correction were employed. Both Sentinel-2 and Landsat-8 images were resampled to 30m pixel size after geometric correction and similar spectral bands for both satellites were selected to create a similar base for these multi-sensor data. Maximum Likelihood (MLC) and Support Vector Machine (SVM) supervised classification methods were applied to both data sets to accurately identify eight different land cover/ use classes. Error matrix was created using same reference points for Sentinel-2 and Landsat-8 classifications. After the classification accuracy, results were compared to find out the best approach to create current land cover/use map of the region. The results of MLC and SVM classification methods were compared for both images.

  17. Wide-area mapping of snow water equivalent by Sentinel-1&2 data

    NASA Astrophysics Data System (ADS)

    Conde, Vasco; Nico, Giovanni; Catalao, Joao; Kontu, Anna; Gritsevich, Maria

    2017-04-01

    The mapping of snow physical properties over large mountain areas of remote areas is an important topic in both climatological studies and hydrological models where the effects of snow melting are modeled and used to forecast extreme flood events. Usually, these models are run using in-situ measurements of snow which are expensive and statistically not representative of the spatial distribution of snow properties due to slope orientation of terrain, local terrain morphology and height as well as vegetation cover. In this work we investigate the use of data acquired by Sentinel-1 and 2 missions using a C-band SAR and multispectral sensor, respectively. The Sentinel-1 SAR data are processed to estimate the Snow Water Equivalent (SWE) using both the radar amplitude and the output of the SAR interferometry processing. Both approaches need in-situ data to process SAR data and calibrate SWE estimates. The use of SAR amplitude to estimate the SWE is well established and the basic idea is that the radar signal backscattered by snow is related to the SWE so, after modeling the relationship between these two quantities at the site of in-situ measurements this relationship can be used to map the SWE at all site where the SAR amplitude information is available. The physical principle used by SAR interferometry is that of phase delay due to propagation in a non-dispersive medium. This implies that the snow is supposed to be dry in order to allow the propagation of the SAR signal. Sentinel-2 images have been used to get land-use maps and identify areas covered by vegetation. Finland has been chosen as a study region with in-situ measurements acquired thanks to the availability of rich database of in-situ measurements of SWE. Sentinel data used in this work have been acquired starting from November 2015. Publication supported by FCT- project UID/GEO/50019/2013 - Instituto Dom Luiz.

  18. Drainage pipe study.

    DOT National Transportation Integrated Search

    1971-05-01

    This report is the result of a research program in which various types of submerged drainage structures were evaluated in an effort to determine the life expectancy of such a structure. California-s method of predicting the behavior pattern of submer...

  19. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage.

    PubMed

    Biron, Vincent L; Kurien, George; Dziegielewski, Peter; Barber, Brittany; Seikaly, Hadi

    2013-02-26

    Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. To compare I&D vs USD of well-defined DNAs, using a randomized controlled clinical trial design. The primary outcome measure was effectiveness (length of hospital stay (LOHS) and safety), and the secondary outcome measure was overall cost to the healthcare system. Patients presenting to the University of Alberta Emergency Department with a well-defined deep neck space abscess were recruited in the study. Patients were randomized to surgical or US-guided drainage, placed on intravenous antibiotics and admitted with airway precautions. Following drainage with either intervention, abscess collections were cultured and drains were left in place until discharge. Seventeen patients were recruited in the study. We found a significant difference in mean LOHS between patients who underwent USD (3.1 days) vs I&D (5.2 days). We identified significant cost savings associated with USD with a 41% cost reduction in comparison to I&D. USD drainage of deep neck space abscesses in a certain patient population is effective, safe, and results in a significant cost savings to the healthcare system.

  20. Surgeon Training, Protocol Compliance, and Technical Outcomes From Breast Cancer Sentinel Lymph Node Randomized Trial

    PubMed Central

    Ashikaga, Takamaru; Harlow, Seth P.; Skelly, Joan M.; Julian, Thomas B.; Brown, Ann M.; Weaver, Donald L.; Wolmark, Norman

    2009-01-01

    Background The National Surgical Adjuvant Breast and Bowel Project B-32 trial was designed to determine whether sentinel lymph node resection can achieve the same therapeutic outcomes as axillary lymph node resection but with fewer side effects and is one of the most carefully controlled and monitored randomized trials in the field of surgical oncology. We evaluated the relationship of surgeon trial preparation, protocol compliance audit, and technical outcomes. Methods Preparation for this trial included a protocol manual, a site visit with key participants, an intraoperative session with the surgeon, and prerandomization documentation of protocol compliance. Training categories included surgeons who submitted material on five prerandomization surgeries and were trained by a core trainer (category 1) or by a site trainer (category 2). An expedited group (category 3) included surgeons with extensive experience who submitted material on one prerandomization surgery. At completion of training, surgeons could accrue patients. Two hundred twenty-four surgeons enrolled 4994 patients with breast cancer and were audited for 94 specific items in the following four categories: procedural, operative note, pathology report, and data entry. The relationship of training method; protocol compliance performance audit; and the technical outcomes of the sentinel lymph node resection rate, false-negative rate, and number of sentinel lymph nodes removed was determined. All statistical tests were two-sided. Results The overall sentinel lymph node resection success rate was 96.9% (95% confidence interval [CI] = 96.4% to 97.4%), and the overall false-negative rate was 9.5% (95% CI = 7.4% to 12.0%), with no statistical differences between training methods. Overall audit outcomes were excellent in all four categories. For all three training groups combined, a statistically significant positive association was observed between surgeons’ average number of procedural errors and their false

  1. Coupling of Sentinel-1, Sentinel-2 and ALOS-2 to assess coseismic deformation and earthquake-induced landslides following 26 June, 2016 earthquake in Kyrgyzstan

    NASA Astrophysics Data System (ADS)

    Vajedian, Sanaz; Motagh, Mahdi; Wetzel, Hans-Ulrich; Teshebaeva, Kanayim

    2017-04-01

    The active deformation in Kyrgyzstan results from the collision between Indian and Asia tectonic plates at a rate of 29 ± 1 mm/yr. This collision is accommodated by deformation on prominent faults, which can be ruptured coseismically and trigger other hazards like landslides. Many earthquake and earthquake-induced landslides in Kyrgyzstan occur in mountainous areas, where limited accessibility makes ground-based measurements for the assessment of their impact a challenging task. In this context, remote sensing measurements are extraordinary useful as they improve our knowledge about coseismic rupture process and provide information on other types of hazards that are triggered during and/or after the earthquakes. This investigation aims to use L-band ALOS/PALSAR, C-band Sentinel-1, Sentinel-2 data to evaluate fault slip model and coseismic-induced landslides related to 26 June 2016 Sary-Tash earthquake, southwest Kyrgyzstan. First we implement three methods to measure coseismic surface motion using radar data including Interferometric SAR (InSAR) analysis, SAR tracking technique and multiple aperture InSAR (MAI), followed by using Genetic Algorithm (GA) to invert the final displacement field to infer combination of orientation, location and slip on rectangular uniform slip fault plane. Slip distribution analysis is done by applying Tikhonov regularization to solve the constrained least-square method with Laplacian smoothing approach. The estimated coseismic slip model suggests a nearly W-E thrusting fault ruptured during the earthquake event in which the main rupture occurred at a depth between 11 and 14 km. Second, the local phase shifts related to landslides are inferred by detailed analysis pre-seismic, coseismic and postseismic C-band and L-band interferograms and the results are compared with the interpretations derived from Sentinel-2 data acquired before and after the earthquake.

  2. Improved drainage with active chest tube clearance.

    PubMed

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. CTC Sentinel. Volume 6, Issue 7, July 2013

    DTIC Science & Technology

    2013-07-01

    researched means to disable fire suppression systems to increase the impact of a plot that was ultimately disrupted by authorities. These failed plots...7 About the CTC Sentinel The Combating Terrorism Center is an independent educational and research institution based in the Department of social...old, after “watching videos of children getting killed in countries like Kashmir and Palestine.”6 He described his actions on behalf of TeaMp0isoN

  4. Preoperative 18F-FDG-PET/CT imaging and sentinel node biopsy in the detection of regional lymph node metastases in malignant melanoma.

    PubMed

    Singh, Baljinder; Ezziddin, Samer; Palmedo, Holger; Reinhardt, Michael; Strunk, Holger; Tüting, Thomas; Biersack, Hans-Jürgen; Ahmadzadehfar, Hojjat

    2008-10-01

    The objective of this study was to evaluate the role of preoperative 18F-fluorodeoxyglucose-positron emission tomography/computed tomography scanning, preoperative lymphoscintigraphy (LS), and sentinel lymph node biopsy in patients with malignant melanoma. Fifty-two patients (36 men: 16 women; mean age 55.0+/-13.0 years; median age 61 years; range 17-76 years) with malignant melanoma were selected. According to the latest version of the American Joint Committee on Cancer staging system, the disease in the study patients was initially classified as either stage I or II. The other primary tumor characteristics were mean Breslow depth=2.87 mm and median=2 mm; range 1-12.0 mm and Clarks levels III-V. None of the study patients had clinical or radiological evidence of regional lymph node metastatic disease. At least one sentinel node was identified in all patients. Preoperative LS detected a total of 111 sentinel lymph nodes (average 2.13 sentinel lymph node per patient) and demonstrated a single nodal draining basin in 38 (73%) patients and multiple (2-3 draining basins) in the remaining 14 (27%) patients. Fourteen out of the 52 patients (27%) had at least one involved sentinel node. Positron emission tomography was true positive in two patients with a sentinel node greater than 1 cm and false positive in two other patients. In this study, the detection of sentinel lymph node by LS and gamma probe had a sensitivity of 100%. In contrast, 18F-FDG-PET imaging demonstrated very low sensitivity (14.3%; 95% CI, 2.5 to 44%) and positive predictive value (50%; 95% CI, 9 to 90%) for localizing the subclinical nodal metastases. The specificity, net present value, and diagnostic accuracy were 94.7, 75, and 73%, respectively. Preoperative fluorodeoxyglucose-positron emission tomography/computed tomography imaging is not able to substitute LS/sentinel lymph node biopsy in patients at stage I or II.

  5. Evaluation of the sustainability of road drainage systems

    NASA Astrophysics Data System (ADS)

    García-Diez, Iván; Palencia, Covadonga; Fernández Raga, María

    2017-04-01

    Water is the most erosive agent that exists on the linear structures, because they are constantly subjected to outdoor condition like irregular infiltration, frosts and different rain intensities. Another variables that highly influence in the entire lifetime of a natural drainage system are the spatial and temporal variability of the rainfall, the soil, the vegetation cover and the design. All this factors are affecting the vulnerability of the clearings and embankments, by wearing away the weakest materials which surround the roads or train rails, producing erosion and very bumpy surfaces. The result is that the original pattern, developped to disminished the lost of soil, is not properly working and it cannot eliminate water, with the consequence destruction of the linear structure after several rainfall periods, and the accumulation of material down slope. The propose of this research focuses on analysing the drainage systems used in spanish roads and railways lines. For this purpose, a revision of the literature has been done, and the main drainage solutions have been recovered, carrying out an evaluation of them from an environmental point of view. This procedure has been requested by several authors in the past (Nwa, E.U. & Twocock, J.G., 1969; Goulter, I.C., 1992), together with the need of designing a more sustainable drainage system. The final objective of this complete revision is to compare objetively the designs to valuate them in order to develop a new drainage patter which minimize the erosion, increasing the durability and effectiveness of the drainage system. For this purpose, it is neccesary to assure that all the systems will be compare under similar parameters of flow rate, vegetation, substrate, lenght, slope and total section. Only the channels pattern and water distribution will change. The analysis has been done following Liu, H. & Zhu, X.B., (2012), who pointed out that the main parameters to take into account to select a road drainage

  6. A UK portrait of wind-induced undercatch in rainfall measurement

    NASA Astrophysics Data System (ADS)

    Pollock, Michael; Quinn, Paul; O'Donnell, Greg; Colli, Matteo; Dutton, Mark; Black, Andrew; Wilkinson, Mark; Kilsby, Chris; Stagnaro, Mattia; Lanza, Luca; O'Connell, Enda

    2017-04-01

    Rainfall is vital to life; civilisation depends upon it. Changing local and regional rainfall regimes toward more intense storm events (e.g. in the UK), increases the existing challenge of accurately measuring and modelling rainfall. Data from rain gauges, often considered to provide the most accurate practicable measure of precipitation at a point in space in time, play a critical role. They are used for, inter alia, flood forecasting and flood risk management; radar calibration and numerical weather prediction models; urban planning and drainage; and water resource management and hydrological modelling. Despite the key importance of these measurements, they remain susceptible to fundamental sources of systematic error which are often not considered when rainfall data are used. Inaccuracies in measurements are compounded in modelling applications by producing potentially misleading or incorrect results; it is therefore of great importance to understand and present uncertainty in observations. Standard practice is to mount rain gauges above the ground surface. This configuration obstructs the prevailing wind which causes an acceleration of airflow above the orifice. Precipitation is deflected away from the orifice and lands 'downstream' of the area represented by the gauge measurement, reducing its collection efficiency (CE). This phenomenon is commonly referred to as 'wind-induced undercatch'. The physical shape of a gauge bears a significant impact on its CE. Computational Fluid Dynamics (CFD) simulations are used to investigate how different shapes of precipitation gauge are affected by the wind. CFD modelling is supported by high-resolution field measurements at several exposed 'Hydro-Met' research stations in the UK. These sites are occupied by rain gauges which are scrutinised in the CFD analyses. The reference measurements at all sites are made within a WMO reference pit, where the rain gauge is mounted with its orifice at ground level and surrounded by an

  7. Subdural drainage versus subperiosteal drainage in burr-hole trepanation for symptomatic chronic subdural hematomas.

    PubMed

    Bellut, David; Woernle, Christoph Michael; Burkhardt, Jan-Karl; Kockro, Ralf Alfons; Bertalanffy, Helmut; Krayenbühl, Niklaus

    2012-01-01

    Symptomatic chronic subdural hematoma (scSDH) is one of the most frequent diseases in neurosurgical practice, and its incidence is increasing. However, treatment modalities are still controversial. The aim of this retrospective single-center study is to compare for the first time two surgical methods in the treatment of subdural hematoma that have been proven to be efficient in previous studies in a direct comparison. We analyzed the data of 143 scSDHs in 113 patients undergoing surgery for subdural hematoma with placement of subperiosteal or subdural drainage after double burr-hole trepanation for hematoma evacuation. Overall, there were no statistically significant differences regarding general patient characteristics, preoperative and postoperative symptoms, postoperative hematoma remnant, rates of recurrences, mortality, complications, and outcome at discharge and at 3-month follow up between the groups. There was a close to significant tendency of lower mortality after placement of subperiosteal drainage system and a tendency towards lower rate of recurrent hematoma after placement of subdural drainage system. Our study shows for the first time a direct comparison of two mainly used surgical techniques in the treatment of scSDH. Both methods proved to be highly effective, and general patient data, complications, outcome and mortality of both groups are equal or superior compared with previously published series. Because there is a clear tendency to less mortality and fewer serious complications, treatment with double burr-hole trepanation, irrigation, and placement of subperiosteal drainage is our treatment of choice in patients with predictable high risk of complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Validating MODIS and Sentinel-2 NDVI Products at a Temperate Deciduous Forest Site Using Two Independent Ground-Based Sensors

    PubMed Central

    Lange, Maximilian; Rebmann, Corinna; Cuntz, Matthias; Doktor, Daniel

    2017-01-01

    Quantifying the accuracy of remote sensing products is a timely endeavor given the rapid increase in Earth observation missions. A validation site for Sentinel-2 products was hence established in central Germany. Automatic multispectral and hyperspectral sensor systems were installed in parallel with an existing eddy covariance flux tower, providing spectral information of the vegetation present at high temporal resolution. Normalized Difference Vegetation Index (NDVI) values from ground-based hyperspectral and multispectral sensors were compared with NDVI products derived from Sentinel-2A and Moderate-resolution Imaging Spectroradiometer (MODIS). The influence of different spatial and temporal resolutions was assessed. High correlations and similar phenological patterns between in situ and satellite-based NDVI time series demonstrated the reliability of satellite-based phenological metrics. Sentinel-2-derived metrics showed better agreement with in situ measurements than MODIS-derived metrics. Dynamic filtering with the best index slope extraction algorithm was nevertheless beneficial for Sentinel-2 NDVI time series despite the availability of quality information from the atmospheric correction procedure. PMID:28800065

  9. Mangrove canopy density analysis using Sentinel-2A imagery satellite data

    NASA Astrophysics Data System (ADS)

    Wachid, M. N.; Hapsara, R. P.; Cahyo, R. D.; Wahyu, G. N.; Syarif, A. M.; Umarhadi, D. A.; Fitriani, A. N.; Ramadhanningrum, D. P.; Widyatmanti, W.

    2017-06-01

    Teluk Jor has alluvium surface sediment that came from volcanic materials. Sea wave that relatively calm and the closed beach shape support the existence of mangrove forest at Teluk Jor. Sentinel-2A imagery has a good spatial and spectral resolution for mangrove density study. The regression between samples and the NDVI values of Sentinel-2A used to analyze the mangrove canopy density. Mangrove canopy density was identified using field survey with transect method. The regression analysis shows field data and NDVI value has correlation R=0.7739 and coefficient of determination R2=0.5989. The result of the analysis shows area of low density 397,900 m2, moderate density 336,200 m2, the high density has 110,300 m2 and very high density has 500 m2. This research also found that mangrove genus in Teluk Jor consists of Rhizopora, Ceriops, Aegiceras and Sonneratia.

  10. Evaluating Metrics of Drainage Divide Mobility

    NASA Astrophysics Data System (ADS)

    Forte, A. M.; Whipple, K. X.; DiBiase, R.; Gasparini, N. M.; Ouimet, W. B.

    2016-12-01

    Watersheds are the fundamental organizing units in landscapes and thus the controls on drainage divide location and mobility are an essential facet of landscape evolution. Additionally, many common topographic analyses fundamentally assume that river network topology and divide locations are largely static, allowing channel profile form to be interpreted in terms of spatio-temporal patterns of rock uplift rate relative to baselevel, climate, or rock properties. Recently however, it has been suggested that drainage divides are more mobile than previously thought and that divide mobility, and resulting changes in drainage area, can potentially induce changes to fluvial topography comparable to spatio-temporal variation in rock uplift, climate, or rock properties. Ultimately, reliable metrics are needed to diagnose the mobility of divides. One such recently proposed metric is cross-divide contrasts in `chi', a measure of the current topology of the drainage network, but cross-divide contrasts in a number of topographic metrics show promise. Here we use a series of landscape evolution modeling scenarios in which we induce divide mobility under different conditions to test the utility of a suite of plausible topographic metrics of divide mobility and compare these to natural examples. Specifically, we test cross-divide contrasts in mean slope, mean local relief, channel bed elevation at a reference drainage area, and chi. Our results highlight that cross-divide contrasts in chi can only be accurately interpreted in terms of divide mobility when uplift, rock erodibility, climate, and base-level are uniform across both river networks on either side of the divide. This is problematic for application of this metric to natural landscapes as (1) uniformity of all of these parameters is exceedingly unlikely and (2) quantifying the spatial patterns of these parameters is difficult. Consequently, as shown here for both simulated and natural landscapes, simple measures of cross

  11. On the synergy of SMAP, AMSR2 AND SENTINEL-1 for retrieving soil moisture

    NASA Astrophysics Data System (ADS)

    Santi, E.; Paloscia, S.; Pettinato, S.; Brocca, L.; Ciabatta, L.; Entekhabi, D.

    2018-03-01

    An algorithm for retrieving soil moisture content (SMC) from synergic use of both active and passive microwave acquisitions is presented. The algorithm takes advantage of the integration of microwave data from SMAP, Sentinel-1 and AMSR2 for overcoming the SMAP radar failure and obtaining a SMC product at enhanced resolution (0.1° × 0.1°) and improved accuracy with respect to the original SMAP radiometric SMC product. A disaggregation technique based on the Smoothing filter based intensity modulation (SFIM) allows combining the radiometric and SAR data. Disaggregated microwave data are used as inputs of an Artificial Neural Networks (ANN) based algorithm, which is able to exploit the synergy between active and passive acquisitions. The algorithm is defined, trained and tested using the SMEX02 experimental dataset and data simulated by forward electromagnetic models based on the Radiative Transfer Theory. Then the algorithm is adapted to satellite data and tested using one year of SMAP, AMSR2 and Sentinel-1 co-located data on a flat agricultural area located in the Po Valley, in northern Italy. Spatially distributed SMC values at 0.1° × 0.1° resolution generated by the Soil Water Balance Model (SWBM) are considered as reference for this purpose. The synergy of SMAP, Sentinel-1 and AMSR2 allowed increasing the correlation between estimated and reference SMC from R ≅ 0.68 of the SMAP based retrieval up to R ≅ 0.86 of the combination SMAP + Sentinel-1 + AMSR2. The corresponding Root Mean Square Error (RMSE) decreased from RMSE ≅ 0.04 m3/m3 to RMSE ≅ 0.024 m3/m3.

  12. Combination of Landsat and Sentinel-2 MSI data for initial assessing of burn severity

    NASA Astrophysics Data System (ADS)

    Quintano, C.; Fernández-Manso, A.; Fernández-Manso, O.

    2018-02-01

    Nowadays Earth observation satellites, in particular Landsat, provide a valuable help to forest managers in post-fire operations; being the base of post-fire damage maps that enable to analyze fire impacts and to develop vegetation recovery plans. Sentinel-2A MultiSpectral Instrument (MSI) records data in similar spectral wavelengths that Landsat 8 Operational Land Imager (OLI), and has higher spatial and temporal resolutions. This work compares two types of satellite-based maps for evaluating fire damage in a large wildfire (around 8000 ha) located in Sierra de Gata (central-western Spain) on 6-11 August 2015. 1) burn severity maps based exclusively on Landsat data; specifically, on differenced Normalized Burn Ratio (dNBR) and on its relative versions (Relative dNBR, RdNBR, and Relativized Burn Ratio, RBR) and 2) burn severity maps based on the same indexes but combining pre-fire data from Landsat 8 OLI with post-fire data from Sentinel-2A MSI data. Combination of both Landsat and Sentinel-2 data might reduce the time elapsed since forest fire to the availability of an initial fire damage map. Interpretation of ortho-photograph Pléiades 1 B data (1:10,000) provided us the ground reference data to measure the accuracy of both burn severity maps. Results showed that Landsat based burn severity maps presented an adequate assessment of the damage grade (κ statistic = 0.80) and its spatial distribution in wildfire emergency response. Further using both Landsat and Sentinel-2 MSI data the accuracy of burn severity maps, though slightly lower (κ statistic = 0.70) showed an adequate level for be used by forest managers.

  13. Global Lakes Sentinel Services: Water Quality Parameters Retrieval in Lakes Using the MERIS and S3-OLCI Band Sets

    NASA Astrophysics Data System (ADS)

    Peters, Steef; Alikas, Krista; Hommersom, Annelies; Latt, Silver; Reinart, Anu; Giardino, Claudia; Bresciani, Mariano; Philipson, Petra; Ruescas, Ana; Stelzer, Kerstin; Schenk, Karin; Heege, Thomas; Gege, Peter; Koponen, Sampsa; Kallio, Karri; Zhang, Yunlin

    2015-12-01

    The European collaborative project GLaSS aims to prepare for the use of the data streams from Sentinel 2 and Sentinel 3. Its focus is on inland waters, since these are considered to be sentinels for land-use- and climate change and need to be monitored closely. One of the objectives of the project is to compare existing water quality algorithms and parameterizations on the basis of in-situ spectral observations and Hydrolight simulations. A first achievement of the project is the collection of over 400 Rrs spectra with accompanying data on CHL, TSM, aCDOM and Secchi depth. Especially the dataset on Lake CDOM measurements represents a rather unique reference dataset.

  14. Ultrasound guided transrectal catheter drainage of pelvic collections.

    PubMed

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  15. Physical modeling of transverse drainage mechanisms

    NASA Astrophysics Data System (ADS)

    Douglass, J. C.; Schmeeckle, M. W.

    2005-12-01

    Streams that incise across bedrock highlands such as anticlines, upwarps, cuestas, or horsts are termed transverse drainages. Their relevance today involves such diverse matters as highway and dam construction decisions, location of wildlife corridors, better-informed sediment budgets, and detailed studies into developmental histories of late Cenozoic landscapes. The transient conditions responsible for transverse drainage incision have been extensively studied on a case-by-case basis, and the dominate mechanisms proposed include: antecedence, superimposition, overflow, and piracy. Modeling efforts have been limited to antecedence, and such the specific erosional conditions required for transverse drainage incision, with respect to the individual mechanisms, remains poorly understood. In this study, fifteen experiments attempted to simulate the four mechanisms and constructed on a 9.15 m long, 2.1 m wide, and 0.45 m deep stream table. Experiments lasted between 50 and 220 minutes. The stream table was filled with seven tons of sediment consisting of a silt and clay (30%) and a fine to coarse sand (70%) mixture. The physical models highlighted the importance of downstream aggradation with regard to antecedent incision versus possible defeat and diversion. The overflow experiments indicate that retreating knickpoints across a basin outlet produce a high probability of downstream flooding when associated with a deep lake. Misters used in a couple of experiments illustrate a potential complication with regard to headward erosion driven piracy. Relatively level asymmetrically sloped ridges allow for the drainage divide across the ridge to retreat from headward erosion, but hindered when the ridge's apex undulates or when symmetrically sloped. Although these physical models cannot strictly simulate natural transverse drainages, the observed processes, their development over time, and resultant landforms roughly emulate their natural counterparts. Proposed originally from

  16. Concordance between peri-areolar blue dye and peri-incisional radiotracer injections for sentinel node mapping in patients with a history of primary breast cancer excisonal biopsy.

    PubMed

    Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M

    2014-01-01

    We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.

  17. Description and Evaluation of the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System

    PubMed Central

    Marriott, Chandra K.; Ostroff, Stephen; Waller, Kirsten

    2011-01-01

    Objectives. We described and evaluated the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System, a voluntary sentinel network of schools that report data on school absenteeism and visits to the school nurse for influenza-like illness (ILI). Methods. Participating schools provided daily absenteeism and ILI data on a weekly basis through an online survey. We used participation and weekly response rates to determine acceptability, timeliness, and simplicity. We assessed representativeness by comparing participating schools with nonparticipating schools. We compared monitoring system data with statewide reports of laboratory-confirmed influenza. Results. Of the 3244 Pennsylvania public schools, 367 (11%) enrolled in the system. On average, 79% of enrolled schools completed the survey each week. Although the peak week of elevated absenteeism coincided with the peak of statewide laboratory-confirmed influenza cases, the correlation between absenteeism and state data was nonsignificant (correlation coefficient = 0.10; P = .56). Trends in ILI correlated significantly with state data (correlation coefficient = 0.67; P < .001). Conclusions. The school-based sentinel system is a simple, acceptable, reliable device for tracking absenteeism and ILI in schools. Further analyses are necessary to determine the comparative value of this system and other influenza surveillance systems. PMID:21566024

  18. A Tale of 2 Techniques: Preoperative Biliary Drainage and Routine Surgical Drainage with Pancreaticoduodenectomy.

    PubMed

    Iskandar, Mazen E; Wayne, Michael G; Steele, Justin G; Cooperman, Avram M

    2018-02-01

    Preoperative drainage of an obstructed biliary tree before pancreaticoduodenal resection (PDR) and placement of intraabdominal drains following pancreatic resection have been suggested to be both unnecessary and associated with a higher complication rate. The evidence for and against that practice is presented and analyzed to highlight its risks and benefits. A selective approach on an individual basis for preoperative biliary decompression is advocated, based on multiple factors. Additionally, the evidence for routine use of surgical drains after PDR is critically reviewed and the rationale for routine drainage is made. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The Lymphatic Anatomy of the Breast and its Implications for Sentinel Lymph Node Biopsy: A Human Cadaver Study

    PubMed Central

    Pan, Wei-Ren; Mann, G. Bruce; Taylor, G. Ian

    2007-01-01

    Background Current understanding of the lymphatic system of the breast is derived mainly from the work of the anatomist Sappey in the 1850s, with many observations made during the development and introduction of breast lymphatic mapping and sentinel node biopsy contributing to our knowledge. Methods Twenty four breasts in 14 fresh human cadavers (5 male, 9 female) were studied. Lymph vessels were identified with hydrogen peroxide and injected with a lead oxide mixture and radiographed. The specimens were cross sectioned and radiographed to provide three dimensional images. Lymph (collecting) vessels were traced from the periphery to the first-tier lymph node. Results Lymph collecting vessels were found evenly spaced at the periphery of the anterior upper torso draining radially into the axillary lymph nodes. As they reached the breast some passed over and some through the breast parenchyma, as revealed in the cross-section studies. The pathways showed no significant difference between male and female specimens. We found also perforating lymph vessels that coursed beside the branches of the internal mammary vessels, draining into the ipsilateral internal mammary lymphatics. In some studies one sentinel node in the axilla drained almost the entire breast. In most more than one sentinel node was represented. Conclusion These anatomical findings are discordant with our current knowledge based on previous studies and demand closer examination by clinicians. These anatomical studies may help explain the percentage of false-negative sentinel node biopsy studies and suggest the peritumoral injection site for accurate sentinel lymph node detection. PMID:18043970

  20. Processing Sentinel-2 data with ATCOR

    NASA Astrophysics Data System (ADS)

    Pflug, Bringfried; Makarau, Aliaksei; Richter, Rudolf

    2016-04-01

    Atmospheric correction of satellite images is necessary for many applications of remote sensing. Among them are applications for agriculture, forestry, land cover and land cover change, urban mapping, emergency and inland water. ATCOR is a widely used atmospheric correction tool which can process data of many optical satellite sensors, for instance Landsat, Sentinel-2, SPOT and RapidEye. ATCOR includes a terrain and adjacency correction of satellite images and several special algorithms like haze detection, haze correction, cirrus correction, de-shadowing and empirical methods for BRDF correction. The atmospheric correction tool ATCOR starts with an estimation of the vertical column Aerosol Optical Thickness (AOT550) at 550 nm. The mean uncertainty of the ATCOR-AOT550-estimation was estimated using Landsat and RapidEye data by direct comparison with sunphotometer data as a reference. For Landsat and RapidEye the uncertainty is ΔAOT550nm ≈ 0.03±0.02 for cloudless conditions with a cloud+haze fraction below 1%. Inclusion of cloudy and hazy satellite images into the analysis results in mean ΔAOT550nm ≈ 0.04±0.03 for both RapidEye and Landsat imagery. About 1/3 of the samples perform with the AOT uncertainty better than 0.02 and about 2/3 perform with AOT uncertainty better than 0.05. An accuracy of the retrieved surface reflectance of ±2% (for reflectance <10%) and ±4% reflectance units (for reflectance > 40%) can be achieved for flat terrain, and avoiding the specular and backscattering regions. ATCOR also supports the processing of Sentinel-2 data. First results of processing S2 data and a comparison with AERONET AOT values will be presented.