Sample records for ulna hook plate

  1. Anatomic Considerations for Plating of the Distal Ulna

    PubMed Central

    Hazel, Antony; Nemeth, Nicole; Bindra, Randy

    2015-01-01

    Purpose The purpose of our study was to examine the anatomy of the distal ulna and identify an interval that would be amenable to plating and would not cause impingement during wrist rotation nor irritation to the extensor carpi ulnaris (ECU) tendon. Methods Six cadaveric forearms were dissected and the arc of the articular surface of the distal ulna was measured. The distal ulna was divided up as a clock face, with the ulnar styloid being assigned the 12 o'clock position, and the location of the ECU was identified accordingly. The distance from the ulnar styloid to where the dorsal sensory ulnar nerve crosses from volar to dorsal was also measured. Based on these measurements a safe zone was defined. Results A safe zone was identified between the 12 and 2 o'clock position on the right wrist, and between the 10 and 12 o'clock on the left wrist. The dorsal sensory branch of the ulnar nerve crossed from volar to dorsal position at a variable location near the ulnar styloid. Two commercially available plates were utilized and could be placed in our designated interval and did not cause impingement when the forearm was rotated fully. Conclusion Our study demonstrates a location for plating of the distal ulna that avoids impingement during forearm rotation and that is outside of the footprint of the ECU subsheath. Clinical Relevance Plating of the distal ulna may be necessary with distal ulna fracture, and although plate placement may be dictated by the fracture pattern, it is important to understand the implications of plate placement. Although the ideal plate may not be possible because of comminution, the patient can be educated in regards to potential for tendon irritation, loss of motion, or need for hardware removal. PMID:26261745

  2. Treatment of proximal ulna and olecranon fractures by dorsal plating.

    PubMed

    Kloen, Peter; Buijze, Geert A

    2009-12-01

    Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid process, nonunions of the proximal ulna, segmental fractures of the proximal ulna extending into the shaft, fractures of the proximal ulna associated with a coronoid fracture. Patients in poor general condition. Soft-tissue defects around the elbow preventing wound closure over the plate. Pediatric fractures with open growth plates where screws would cross the physis. Posterior approach to the elbow. Hinging the fracture site open by extension of the proximal fragment based on triceps insertion. Fracture involvement of the coronoid with a large displaced fracture fragment can generally be reduced through the fracture side. Reconstruction with temporary Kirschner wires. Fixation by placing a (precontoured) plate around the tip of the olecranon with a long intramedullary screw and orthogonal (uni)cortical screws in the shaft. Radial head pathology can be addressed - if needed - through the same incision. Internal fixation, resection or prosthetic replacement of the radial head is done based on injury pattern/stability. Functional rehabilitation using active assisted range of motion of the elbow may be started immediately out of splint. Posterior splint for 7-10 days to allow wound healing. Between 2003 and July 2008, 26 patients were treated with posterior plating of the proximal ulna and olecranon using this strategy. There were 23 acute fractures (of which one was referred for revision after suboptimal fixation a few days earlier), one nonunion that became traumatized, and two nascent malunions. A midline posterior approach allowed addressing both ulna and radial head pathology. The plate was contoured to wrap around the olecranon. All fractures healed. There were one postoperative infection, one

  3. Three-dimensional scapular dyskinesis in hook-plated acromioclavicular dislocation including hook motion.

    PubMed

    Kim, Eugene; Lee, Seunghee; Jeong, Hwa-Jae; Park, Jai Hyung; Park, Se-Jin; Lee, Jaewook; Kim, Woosub; Park, Hee Jin; Lee, So Yeon; Murase, Tsuyoshi; Sugamoto, Kazuomi; Ikemoto, Sumika

    2018-06-01

    The purpose of this study is to analyze the 3-dimensional scapular dyskinesis and the kinematics of a hook plate relative to the acromion after hook-plated acromioclavicular dislocation in vivo. Reported complications of acromioclavicular reduction using a hook plate include subacromial erosion and impingement. However, there are few reports of the 3-dimensional kinematics of the hook and scapula after the aforementioned surgical procedure. We studied 15 cases of acromioclavicular dislocation treated with a hook plate and 15 contralateral normal shoulders using computed tomography in the neutral and full forward flexion positions. Three-dimensional motion of the scapula relative to the thorax during arm elevation was analyzed using a computer simulation program. We also measured the distance from the tip of the hook plate to the greater tuberosity, as well as the angular motion of the plate tip in the subacromial space. Decreased posterior tilting (22° ± 10° vs 31° ± 8°) in the sagittal plane and increased external rotation (19° ± 9° vs 7° ± 5°) in the axial plane were evident in the affected shoulders. The mean values of translation of the hook plate and angular motion against the acromion were 4.0 ± 1.6 mm and 15° ± 8°, respectively. The minimum value of the distance from the hook plate to the humeral head tuberosity was 6.9 mm during arm elevation. Acromioclavicular reduction using a hook plate may cause scapular dyskinesis. Translational and angular motion of the hook plate against the acromion could lead to subacromial erosion. However, the hook does not seem to impinge directly on the humeral head. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    PubMed

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  5. Subacromial morphometric assessment of the clavicle hook plate.

    PubMed

    ElMaraghy, Amr W; Devereaux, Moira W; Ravichandiran, Kajeandra; Agur, Anne M

    2010-06-01

    Clavicle hook plates are an effective plate fixation alternative for distal clavicle fractures and severe acromioclavicular joint dislocations. However, post-operative complications associated with the subacromial portion of the hook include acromial osteolysis and subacromial impingement. We examine and quantify the three-dimensional position of the subacromial portion of the hook plate relative to surrounding acromial and subacromial structures in a series of cadaveric shoulders to determine if hook positioning predisposes the shoulder to these noted post-operative complications. Fifteen cadaveric shoulders (seven males, eight females) were implanted with 15- or 18-mm hook plates. Dimensions of the acromion and hook plate were digitised and reconstructed into a three-dimensional model to measure acromion dimensions and distances of the subacromial hook relative to surrounding acromial and subacromial structures. Inter-specimen dimensions of the acromion were highly variable. Mean acromion width and thickness were greater in males than in females (p=0.01). The posterior orientation of the subacromial hook varied widely (mean posterior implantation angle=32.5+/-20 degrees, range 0-67 degrees). The hook pierced the subacromial bursa in 13/15 specimens, made contact with the belly of the supraspinatus muscle in 9/15 specimens, and had focal contact at the hook tip with the undersurface of the acromion in 9/15 specimens. The wide range of acromial dimensions leads to a high degree of variability in the positioning of the subacromial hook. The observed frequency of hook contact with surrounding subacromial structures in a static shoulder confirms that the position of the hook portion of the implant can predispose anatomic structures to the post-operative complications of subacromial impingement and bony erosion. Copyright 2009 Elsevier Ltd. All rights reserved.

  6. Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogs.

    PubMed

    Ramírez, J M; Macías, C

    2016-03-01

    To describe the outcome of bone plate fixation of distal radius and ulna fractures in toy breed dogs treated with conventional bone plates. Records of 15 toy breed dogs with distal radius and ulna fractures were retrospectively reviewed for signalment, method of fixation, complications and clinical and radiographic assessments. A telephone-based owner questionnaire was conducted to determine long-term function and client satisfaction. Age ranged from 4 months to 6 years. Body weight ranged from 1 to 4 kg. Dynamic compression plates were used in 13 dogs and veterinary cuttable plates were used in 2 dogs as the means of fixation. Full radiographic and clinical follow-up data were available for 10 dogs and follow-up was performed between 6 and 8 weeks postoperatively. At that time, all fractures had healed and return to function was considered excellent in all 10 dogs. Five dogs did not return for hospital evaluation because they were judged by their owners to be free of lameness. In two cases, owners could not be contacted by telephone, but the referring veterinarians reported the dogs to be asymptomatic. No major complications occurred. Conventional bone plates are suitable choices for stabilisation of distal radius and ulna fractures in toy breed dogs and are not necessarily correlated with high rates of complication. © 2016 Australian Veterinary Association.

  7. Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

    PubMed

    Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih

    2015-11-01

    Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.

  8. [Case-control study on endobutton plate or clavicular hook plate for the repair of acromioclavicular joint dislocations].

    PubMed

    Zhu, Li; Yang, He-Jie; Zhao, Wan-Jun; Yang, Wu-Min; Zhou, Hui

    2012-02-01

    To compare the treatment results between Endobutton plate and clavicular hook plate for the treatment of acromioclavicular joint dislocations. From January 2009 to September 2010, 30 patients with acromioclavicular joint dislocations were treated with two different fixations: Endobutton plate (15 patients, including 12 males and 3 females, with a mean age of 38.5 +/- 8.2 years) and clavicular hook plate (15 patients, including 14 males and 1 female, with the mean age of 33.8 +/- 5.9 years). The mean operative time and blood loss were compared between the two groups. Joint function was assessed by the Karlsson standard. The mean operative time of the Endobutton group and the hook plate group were (61 +/- 8.6) min and (40 +/- 5.6) min. The average blood loss were (93 +/- 8.4) ml and (100 +/- 12.6) ml. There was no statistical difference between the two groups in the average blood loss and the mean operative time. According to the Karlsson standard, 13 patients got an excellent result, 2 good in the Endobutton group; and 7 patients got an excellent result and 7 good in hook plate group. The therapeutic effect in Endobutton group was better than that of hook plate group. In the treatment of acromioclavicular dislocation, fixation with Endobutton plate is believed to be better than hook plate fixation. It is an effective method for the repair of acromioclavicular joint dislocations in a short term. But its long term effects still need further follow up.

  9. Clavicular hook plate for grade-III acromioclavicular dislocation.

    PubMed

    Steinbacher, Gilbert; Sallent, Andrea; Seijas, Roberto; Boffa, Juan Manuel; Espinosa, Wenceslao; Cugat, Ramón

    2014-12-01

    To review the outcomes of clavicular hook plate fixation for grade-III acromioclavicular (AC) dislocation in young athletes. Medical records of 14 male and 5 female athletes aged 18 to 49 (mean, 29) years who underwent fixation with a 3.5-mm-thick, 15-mm-long clavicular hook plate for acute grade-III AC dislocation were reviewed. The visual analogue score for pain and the Constant shoulder score were assessed. The mean follow-up was 4.2 years. The mean visual analogue score for pain was 1.8 (range, 1-3). The Constant shoulder score was excellent (≥ 90) in 14 patients and good (83-89) in 5 patients. All patients achieved range of motion equal to that of the contralateral side at week 5. Sports activities were resumed by month 6 at the latest. The clavicular hook plate for grade- III AC dislocation enables quick return to sports activities and achieves good-to-excellent functional outcome.

  10. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation.

    PubMed

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate.

  11. Morphological analysis of acromion and hook plate for the fixation of acromioclavicular joint dislocation.

    PubMed

    Yoon, Jong Pil; Lee, Yeon Soo; Song, Geun Soo; Oh, Joo Han

    2017-03-01

    Acromioclavicular (AC) joint dislocation is a common sports injury. Hook plate fixation is currently widely used to treat this injury, as it can promote the natural healing of the ligament with good clinical outcomes. However, subacromial erosion and impingement are frequently observed post-operatively. It was hypothesized that the morphology and the contact characteristics between the hook portion and the acromion are the main causes of complications after hook plate fixation with the currently available commercial designs. Three-dimensional reconstructed models of the AC joint obtained from the computed tomographic scans of 23 male and 23 female patients (mean age, 61.1 ± 6.3 years) were evaluated, and multiple anatomical parameters were measured. For the subacromial positioning of the hook plate, an actual hook plate (Synthes Inc., West Chester, PA, USA) was scanned, and the contact between the hook plate and the acromion was estimated. The thicknesses of the acromion and distal clavicle were 9.7 ± 1.5 mm (10.7 mm in men; 8.6 mm in women) and 11.3 ± 1.6 mm (11.6 mm in men; 10.0 mm in women), respectively. The width of the acromion was 28.5 ± 3.6 mm. The mean inclination angle between the hook plate and the acromion was 29.3° ± 9.7° (27.9° in men; 30.6° in women). The hook plate made a point contact with the acromion at 9.2 ± 3.3 mm (31.5 %) from the lateral end of the acromion. The results revealed that the hook made a pinpoint contact with the undersurface of the acromion, and this might explain why complications commonly occur after hook plate fixation. The force concentration phenomenon associated with the hook plate of existing designs results from cases of morphological mismatch, such as excessive inclination and improper occupation of the subacromial space.

  12. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation

    PubMed Central

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Introduction: Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. Methods: A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. Results: According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). Conclusion: The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate. PMID

  13. Surgical treatment of acute acromioclavicular joint dislocations: hook plate versus minimally invasive reconstruction.

    PubMed

    Metzlaff, S; Rosslenbroich, S; Forkel, P H; Schliemann, B; Arshad, H; Raschke, M; Petersen, W

    2016-06-01

    This study was performed to compare the clinical results of a minimally invasive technique for acute acromioclavicular (AC) joint dislocation repair with the traditional hook plate fixation. Forty-four patients with an acute (within 2 weeks after trauma) complete AC joint separation (35 male, nine female; median age 36.2 years, range 18-56) underwent surgical repair with either a minimally invasive AC joint repair or a conventional hook plate. Functional outcome was evaluated using the Constant-Murley Score (CMS), the TAFT score and the AC joint instability score (ACJI). Radiographic evaluation was performed with bilateral anterior-posterior (a.p.) stress and Alexander views. All patients were available after a median follow-up of 32 months (range 24-51). There were no significant differences in the mean CMS, Taft score and the ACJI between the two groups. The radiological assessment revealed no significant difference in the coracoclavicular distance. In both groups, a slight loss of reduction was observed. Periarticular ossification was seen in 11 patients of the minimally invasive AC joint repair and eight patients of the hook plate group but this did not affect the final outcome. Hook plates were removed after a median interval of 11.9 weeks (range 10-13). Good clinical results can be achieved with both minimally invasive AC joint repair and hook plate fixation. However, in the hook plate group a second operation is mandatory for plate removal. III.

  14. [Treatment of sternoclavicular joint dislocation with sternoclavicular hook plate fixation].

    PubMed

    Liu, Pan; Yuan, Jia-bin; Liu, Zhong-qian; Lu, Bing; Wang, Yue

    2015-08-01

    To evaluate the technique and therapeutic effect of sternoclavicular hook plate fixation in treating sternoclavicular joint (SCJ) dislocation. From January 2010 to March 2014,6 patients with SCJ dislocation were treated with sternoclavicular hook plate fixation in our hospital. Among the 6 patients, 5 patients were male and 1 patient was female, and the average age was 34 years, ranging from 26 to 48 years. The course of the disease ranged from 3 to 20 days. All the SCJ dislocations were caused by external injury and accompanied with the symptoms of swelling pain and obvious shoulder joint activity restricted in affected side. All SCJ dislocations were anterior dislocation by the diagnosis of X-ray and CT scan. The postoperative curative effect was evaluated according to Rockwood score. All the patients' operative incision were healed well and in good appearance. X-ray showed that the dislocated SCJ was well reduced and the plate was on right position. All the 6 patients were followed up for 4 to 18 months, with an average of 12 months. The results were evaluated according to Rockwood score, 4 got excellent results, 1 good and 1 fair. No fixation loosening, redislocation or side injury such as vessel, nerve or pleura injury were found. With sternoclavicular hook plate fixation, SCJ dislocation could be reduced while keeping its amphiarthrodial function and the completeness of the cartilage surface. Sternoclavicular hook plate fixation has advantages of safety and stabilization in fixation, and patients can begin function exercises earlier.

  15. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs.

    PubMed

    Watrous, Gwyneth K; Moens, Noel M M

    2017-04-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.

  16. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs

    PubMed Central

    Watrous, Gwyneth K.; Moens, Noel M.M.

    2017-01-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg. PMID:28373730

  17. The clavicle hook plate for Neer type II lateral clavicle fractures.

    PubMed

    Renger, R J; Roukema, G R; Reurings, J C; Raams, P M; Font, J; Verleisdonk, E J M M

    2009-09-01

    To evaluate functional and radiologic outcome in patients with a Neer type II lateral clavicle fracture treated with the clavicle hook plate. Multicenter retrospective study. Five level I and II trauma centers. Forty-four patients, average age 38.4 years (18-66 years), with a Neer type II lateral clavicle fracture treated with the clavicle hook plate between January 1, 2003, and December 31, 2006. Open reduction and internal fixation with the clavicle hook plate. Removal of all 44 implants after consolidation at a mean of 8.4 months (2-33 months) postoperatively. At an average follow-up of 27.4 months (13-48 months), functional outcome was assessed with the Constant-Murley scoring system. Radiographs were taken to evaluate consolidation and to determine the distance between the coracoid process and the clavicle. The average Constant score was 92.4 (74-100). The average distance between the coracoid process and the clavicle was 9.8 mm (7.3-14.8 mm) compared with 9.4 mm (6.9-14.3 mm) on the contralateral nonoperative side. We observed 1 dislocation of an implant (2.2%), 2 cases of pseudarthrosis (4.5%), 2 superficial wound infections (4.5%), 2 patients with hypertrophic scar tissue (4.5%), and 3 times an acromial osteolysis (6.8%). Thirty patients (68%) reported discomfort due to the implant. These implant-related complaints and the acromial osteolysis disappeared after removal of the hook plate. With all the patients, direct functional aftercare was possible. The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.

  18. Absorption of metals in mulloway (Argyrosomus japonicus) after ingesting nickel-plated carbon-steel hooks.

    PubMed

    McGrath, Shane P; Reichelt-Brushett, Amanda J; Butcher, Paul A; Cairns, Stuart C

    2014-08-01

    Previous research has alluded to the potential of metals being absorbed by fish after ingesting fishing hooks, which may have adverse effects on fish health and the organisms that consume them. Subsequently, this study aimed to quantify the potential of mulloway (Argyrosomus japonicus) to absorb metals during the decay of ingested nickel-plated carbon-steel hooks. Twenty-five treatment fish were allowed to ingest nickel-plated carbon-steel hooks during angling and then monitored with 25 controls (untreated fish) for up to 42 days for hook ejection and mortality. Blood, liver and muscle samples were collected from treatment, control and 14 wild-caught individuals to determine the concentrations of chromium, cobalt, copper, iron, manganese and nickel. The results showed that increased oxidation influenced hook ejection, and that hook-ingested fish had significantly elevated concentrations of nickel in their liver and blood, but not muscle. This research has shown that there is an avenue for metal absorption from ingested hooks. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study.

    PubMed

    Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih

    2016-11-01

    Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Arthroscopic evaluation for omalgia patients undergoing the clavicular hook plate fixation of distal clavicle fractures

    PubMed Central

    2014-01-01

    Background The aim of this study is to investigate the anatomic changes in the shoulder joints responsible for omalgia after the clavicular hook plate fixation under arthroscope. Methods Arthroscopic examination was carried out for 12 omalgia patients who underwent clavicular hook plate fixation due to distal clavicle fractures. Functional outcome of shoulder was measured by the Japanese Orthopaedic Association (JOA) score before and after the withdrawal of the fixation plate. Results The rotator cuff compression by the clavicular hook was arthroscopically observed in 11 of the 12 cases. The JOA scores of the shoulder were significantly improved at 1 month after the withdrawal of the fixation plate (pain, 28 ± 2.4 vs. 15 ± 5.2; function, 19.2 ± 1.0 vs. 11.7 ± 1.9; range of movements, 26.8 ± 2.6 vs. 14.8 ± 3.4) compared with before. Conclusions The impingement of the hook to the rotator cuff may be the main cause for the omalgia. The appropriate hook and plate that fit to the curve of the clavicle as well as the acromion are necessary to decrease the severity of omalgia. PMID:24917508

  1. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  2. [Treatment of proximal ulna and olecranon fractures by reconstruction plate combined with tension band wiring].

    PubMed

    Teng, Lin; Zhong, Gang; Xiao, Cong; Liu, Gang; Xiang, Zhou; Cen, Shiqiang; Huang, Fuguo

    2011-01-01

    OBJECTIVE To review the efficacy of reconstruction plate combined with tension band wiring for treating proximal ulna and olecranon fractures. Between November 2004 and September 2009, 10 patients with proximal ulna and olecranon fractures were treated by reconstruction plate combined with tension band wiring. There were 6 males and 4 females with an average age of 45.3 years (range, 21-75 years). Five fractures were caused by traffic accident, 2 by falling from height, 2 by tumbling, and 1 by a machine strangulation. The locations were the left side and the right side in 5 cases respectively. One case was open fracture (Gustilo II) and the other 9 were closed fractures. Olecranon fractures included 4 cases of traverse fractures and 6 cases of comminuted fractures, and proximal ulna fractures included 6 cases of comminuted fractures and 4 cases of oblique fractures. The combined fractures included 6 radial head fractures, 4 coronoid process fractures, 2 proximal humerus fractures, and 3 scapula fractures; other injury included 1 elbow dislocation and 1 shoulder dislocation. Two patients had secondary operation; the other 8 patients received the primary operations and the time from injury to operation varied from 7 days to 20 days, with an average of 11 days. One case had infection at the incision 1 week after operation, and recovered after 2 months of antibiotics and debridement; incisions healed by first intention in other 9 patients. All patients were followed up 12-64 months (mean, 40.5 months). The X-ray films showed that fracture healing was achieved at 10-24 weeks (mean, 12 weeks). There was no ulnar nerve symptom in all cases. Heterotopic ossification occurred in 1 case at 2 months and stiffness of the elbow in 1 case at 3 months after operation; they were both cured after symptomatic treatment. Proximal migration of Kirschner wires was found in 1 case at 6 months after operation, whose implants were taken out at 9 months after the first operation because

  3. In vivo analysis of acromioclavicular joint motion after hook plate fixation using three-dimensional computed tomography.

    PubMed

    Kim, Yoon Sang; Yoo, Yon-Sik; Jang, Seong Wook; Nair, Ayyappan Vijayachandran; Jin, Hyonki; Song, Hyun-Seok

    2015-07-01

    The clavicle hook plate can be used to treat acromioclavicular and coracoclavicular ligament injury or distal clavicular fracture with comminution. However, the hook plate can induce subacromial impingement, resulting in discomfort from the hardware. Our inclusion criteria were (1) men and women aged older than 20 years and (2) the presence of comminuted distal clavicular fractures (Neer type IIB) fixed with a hook plate (Synthes, Oberdorf, Switzerland). Three-dimensional computed tomography was obtained before removal of the hook plate. Seven patients were enrolled prospectively. The mean age was 42 years (range, 24-60 years). Zero degree images and abduction images were obtained. The sagittal cut surface was obtained 5 mm medial from the distal clavicle. The equator of the cut surface of the clavicle was compared with the full abduction model to analyze rotation. The center of the cut surface of the clavicle was compared with the full abduction model to analyze translation. The average difference in rotation of the distal clavicle between both shoulders was 16° (range, 3°-22°; P = .001). The mean difference in anterior translation of the distal clavicle was 2.2 mm (range, -0.7 to 5.6 mm; P = .030). Hook plate fixation at the acromioclavicular joint causes decreased internal rotation and increased anterior translation of the distal clavicle with respect to the medial acromion, indicating that the scapula relative to the thorax has decreased posterior tilting and increased external rotation in shoulders fixed using a hook plate. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Hook plate fixation for acute acromioclavicular dislocations without coracoclavicular ligament reconstruction: a functional outcome study in military personnel.

    PubMed

    Kumar, Narinder; Sharma, Vyom

    2015-08-01

    The aim of our study was to evaluate the shoulder function after clavicular hook plate fixation of acute acromioclavicular dislocations (Rockwood type III) in a population group consisting exclusively of high-demand military personnel. This prospective study was carried out at a tertiary care military orthopaedic centre during 2012-2013 using clavicular hook plate for management of acromioclavicular injuries without coracoclavicular ligament reconstruction in 33 patients. All patients underwent routine implant removal after 16 weeks. The functional outcome was assessed at 3, 6 and 12 months after hook plate removal and 2 years from the initial surgery using the Constant Murley and UCLA Scores. All the patients were male serving soldiers and had sustained acromioclavicular joint dislocation (Rockwood type III). Mean age of the patient group was 34.24 years (21-55 years). The mean follow-up period in this study was 23.5 months (20-26 months) after hook plate fixation and an average of 19.9 months (17-22 months) after hook plate removal. The average Constant Score at 3 months after hook plate removal was 60.3 as compared to 83.7 and 90.3 at 6 months and 1 year, respectively, and an average of 91.8 at the last follow-up that was approximately 2 years after initial surgery which was statistically significant (p value <0.05). The UCLA Score was an average of 15.27, 25.9 and 30.1 at 3, 6 months and 1 year, respectively, after removal of hook plate which improved further an average of 32.3 at the last follow-up, which was also statistically significant (p value <0.05). Clavicular hook plate fixation without coracoclavicular ligament reconstruction is a good option for acute acromioclavicular dislocations producing excellent medium-term functional results in high-demand soldiers.

  5. Does Subacromial Osteolysis Affect Shoulder Function after Clavicle Hook Plating?

    PubMed Central

    Sun, Siwei; Gan, Minfeng; Sun, Han; Wu, Guizhong; Yang, Huilin; Zhou, Feng

    2016-01-01

    Purpose. To evaluate whether subacromial osteolysis, one of the major complications of the clavicle hook plate procedure, affects shoulder function. Methods. We had performed a retrospective study of 72 patients diagnosed with a Neer II lateral clavicle fracture or Degree-III acromioclavicular joint dislocation in our hospital from July 2012 to December 2013. All these patients had undergone surgery with clavicle hook plate and were divided into two groups based on the occurrence of subacromial osteolysis. By using the Constant-Murley at the first follow-up visit after plates removal, we evaluated patients' shoulder function to judge if it has been affected by subacromial osteolysis. Results. We have analyzed clinical data for these 72 patients, which shows that there is no significant difference between group A (39 patients) and group B (33 patients) in age, gender, injury types or side, and shoulder function (the Constant-Murley scores are 93.38 ± 3.56 versus 94.24 ± 3.60, P > 0.05). Conclusion. The occurrence of subacromial osteolysis is not rare, and also it does not significantly affect shoulder function. PMID:27034937

  6. [Complications of treatment of acromioclavicular joint dislocation and unstable distal clavicular fracture with clavicular hook plate].

    PubMed

    Zhu, Yi-Yong; Cui, Heng-Yan; Jiang, Pan-Qiang; Wang, Jian-Liang

    2013-11-01

    To investigate the causes and prevention of the complications about treatment of acromioclavicular joint dislocation (Tossy III) and unstable distal clavicular fracture (Neer II) with clavicular hook plate. From January 2001 to December 2011, 246 patients with acromioclavicular joint dislocation (Tossy III) and 222 patients with unstable distal clavicular fracture (Neer II) were treated with acromioclvicular hook plate fixation,including 348 males and 120 females with an average age of 45.4 years old ranging from 21 to 80 years old. The mean time from injury to operation was 30.8 hours (ranged from 1 h to 15 d). All patients had normal shoulder function before injury. According to Karlsson evaluation standard, the cases with excellent and good function of the shoulder joint were regarded as the normal group, and the cases with poor function of shoulder joint as the abnormal group. The comparison of the range of forward flexion,backward stretch, adduction, abduction and elevation of shoulder joints between two groups was performed. The data of impingement, subacromial osteolysis, acromioclavicular arthritis, clavicular stress fracture, downward acromioclavicular joint subluxation, hook cut-out and hook break were summarized. All patients were followed up from 8 to 48 months with an average of 12.5 months. The results were excellent in 308 cases,good in 76,and poor in 84 according to Karlsson evaluation. The excellent and good rate was 82.1%. The difference of the range of forward flexion, backward stretch, adduction, abduction and elevation of shoulder joints between two groups had a statistically significant difference (P < 0.01). Among 84 poor cases, there were 41 (8.76%) in acromial impingement or inadequate place of plate hook, 12 (2.56%) with subacromial osteolysis or/and bursitis, 10 (2.14%) with acromioclavicular arthritis or painful shoulder caused by delayed dirigation,7 (1.50%) with clavicular stress fracture or interal plate upward, 6 (1.28%) with

  7. 3. This machine in building #7 plated the hooks used ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. This machine in building #7 plated the hooks used on the cross chains in tire chains, by the 'pean' or mechanical process. This process was replaced when coated wire was introduced. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA

  8. [EFFECTIVENESS OF SHARP TEETH HOOK PLATE FOR TREATMENT OF OLECRANON FRACTURES].

    PubMed

    Yin, Qudong; Gu, Sanjun; Liu, Jun; Wu, Yongwei; Lu, Yao; Ma, Yunhong; Sheng, Youyin

    2016-09-08

    To investigate the effectiveness of sharp teeth hook plate by cutting for the treatment of olecranon fractures by comparison with Kirschner wire tension belt and locking plate. Between January 2011 and April 2015, 32 cases of olecranon fractures were treated. Fracture was fixed with sharp teeth hook plate by cutting in 12 cases (trial group) and with Kirschner wire tension belt or locking plate in 20 cases (control group). There was no significant difference in gender, age, side and type of fracture, and time from injury to operation between 2 groups ( P >0.05). The healing time of fractures and complications were recorded. At 1 year after operation, the subjective function results were evaluated according to Disability of Arm, Shoulder, and Hand (DASH) score, and objective function results by Mayo Elbow Score (MEPS); visual analogue scale (VAS) was used for elbow joint pain, and range of motion of flexion and extension of elbow joint was measured. All incisions healed by first intention, with no vascular and nerve injuries. All patients were followed up 12-36 months with an average of 18 months. All fractures healed, and there was no significant difference in the healing time between 2 groups ( P >0.05). Loosening of Kirschner wire occurred in 2 cases of control group, but no loosening of internal fixation was observed in trial group after operation. There was no significant difference in the incidence of complications between 2 groups ( P >0.05). The DASH, MEPS, VAS score, and range of motion of flexion in trial group were superior to those in control group, showing significant differences ( P <0.05) at 1 year after operation. There was no significant difference in range of motion of extension between 2 groups ( P >0.05). Sharp teeth hook plate for treatment of olecranon fractures overcomes the shortcomings that Kirschner wire tension is easy to slide and locking plate has a compression effect on triceps tendon, so it has good effectiveness.

  9. Acromioclavicular joint reconstruction by coracoid process transfer augmented with hook plate.

    PubMed

    Wang, Yeming; Zhang, Jianguo

    2014-06-01

    Various techniques have been reported for the treatment of chronic acromioclavicular (AC) joint separation. The purpose of this study was to evaluate the results of surgical construction of coracoclavicular ligament using coracoid process transfer augmented with a hook plate fixation. Twenty-one patients treated with coracoid process transfer augmented with a hook plate fixation for chronic type III and V AC injuries were retrospectively analysed in 2003-2009. The age of the patients ranged from 23 to 58 years with an average age of 41.6 years. The patients were followed up clinically and radiographically, with an average of 33.0 months. Functional status and the ability to return to work were recorded during follow-up. Constant score and visual analogue scale (VAS) for pain were measured. The mean Constant score has increased from 70.9 points preoperatively to 90.7 points at follow-up. The mean VAS score has decreased from 4.7 preoperatively to 1.2 at follow-up. The average abduction was 172°, forward flexion was 170° and external rotation was 56°. There were 10 excellent results, 10 good results and one fair result. All patients had resumed their job or returned to original sport activity at mean 3.7 months postoperatively. No reduction loss was observed after plate removal and the final follow-up. Despite retrospective nature of the study, the outcomes of surgical construction with process transfer augmented with hook plate fixation are promising for chronic type III and V AC injuries. Therapeutic level IV. Retrospective case series, treatment study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. [Clinical applications of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation].

    PubMed

    Chen, Fang-Hu; Zhao, Xiao-Ping; Zheng, Wen-Biao; Zeng, Han-Bing; Ran, Bo; Huang, Hui; Wang, Hai-Bao

    2013-05-01

    To observe the clinical therapeutic effects of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation. From June 2010 to June 2012, 7 patients with sternoclavicular joint dislocation were treated with sternoclavicular hook plate fixation. Among the 7 patients, 5 patients were male and 2 patients were female, and the average age was 42.3 years, ranging from 38 to 54 years. The course of the disease ranged from 1 to 4 weeks. All the patients had trauma history. The clinical manifestations included: obvious swelling and pain of sternoclavicular joint, restricted shoulder joint activity. The sternoclavicular joint dislocation was proved by preoperative X-ray and CT. The postoperative curative effect was evaluated according to Rockwood scoring method. According to Rockwood scoring method, the excellent results obtained in 6 cases, good in 1. There were no complications such as internal fixation loosening or broken, second dislocation, pain in the sternoclavicular joint, and deformity. The function of shoulder joint was good, and the limb activity was free and no pain appeared. The sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation has follow advantages: simple procedure, stable fixation, definite therapeutic effects.

  11. [The effects of hook plates on the subacromial space--a clinical and MRT study].

    PubMed

    Hackenberger, J; Schmidt, J; Altmann, T

    2004-01-01

    The analysis of middle- and long-term results after treatment of acromioclavicular joint injuries with a hook plate as a temporary implant and a comparison of the results with those described in literature have been made. In a retrospective study we were able to conduct follow-up examinations on 28 out of 39 Tossy III patients (72 %) who received surgical treatment using a hook plate according to Dreithaler. Examinations took place on average 3.0 (1.2-5.6) years after surgery. A special focus of attention was the effect of the hook plate on the subacromial space. Accordingly, physical examination was supplemented by sonography of the shoulder as well as comparative bilateral shoulder MRI. 86 % of our patients expressed satisfaction with the functional outcome of surgery as opposed to 54 % concerning its cosmetic result. In shoulder sonography no patient turned out to have suffered a higher grade rotator cuff lesion, whereas age-related degenerative alterations were found in 46 % of the patients. Instability under load was found in 7 patients (25 %). Among these were 3 with severe instability (11 %). 2 patients (7 %) were found to have a permanent subluxation of the acromioclavicular joint with partial range of motion impairment. All scores monitored (DASH, Taft, Constant-Murley) on average returned good to excellent results. MRI scans displayed no case of higher grade rotator cuff lesion. In accordance with the findings of ultrasound imaging a higher incidence of extraarticular ossification was found as well as, in some cases, arthrosis of the acromioclavicular joint. In our opinion, the hook plate designed by Dreithaler is easy to handle and serves as a qualified implant for temporary stabilisation of the acromioclavicular joint with middle- and long-term good to excellent results.

  12. Short-term outcomes of arthroscopic TightRope® fixation are better than hook plate fixation in acute unstable acromioclavicular joint dislocations.

    PubMed

    Bin Abd Razak, Hamid Rahmatullah; Yeo, Eng-Meng Nicholas; Yeo, William; Lie, Tijauw-Tjoen Denny

    2018-07-01

    The aim of this study was to compare the short-term outcomes of arthroscopic TightRope ® fixation with that of hook plate fixation in patients with acute unstable acromioclavicular joint dislocations. We conducted a prospective case-control study of twenty-six patients with an acute ACJ dislocation who underwent surgical repair with either an arthroscopic TightRope ® fixation or a hook plate from 2013 to 2016. Clinical and radiological data were collected prospectively. Clinical outcomes were evaluated using the Constant Score, the University of California at Los Angeles (UCLA) Shoulder Score, Oxford Shoulder Score as well as the visual analogue scale. Radiological outcomes were assessed with the coracoclavicular distance (CCD). Sixteen patients underwent arthroscopic TightRope ® fixation, while 10 patients underwent hook plate fixation. There were no significant differences in the preoperative variables except for the mean UCLA 4b infraspinatus score (TightRope ® 2.8 vs. hook plate 3.8; p = 0.030). Duration of surgery was significantly longer in the TightRope ® group. At 1 year post-operatively, the TightRope ® group had a significantly better Constant Score and CCD with no complications. All patients with hook plate fixation had to undergo a second procedure for removal of implant, and 3 patients had complications. Arthroscopic TightRope ® fixation is a good option for the treatment of acute unstable ACJ dislocations. It has better short-term clinical and radiological outcomes as well as lesser complications when compared to hook plate fixation. Therapeutic, Level III.

  13. Clinical efficacies of coracoclavicular ligament reconstruction using suture anchor versus hook plate in the treatment of distal clavicle fracture.

    PubMed

    Yan, H W; Li, L; Wang, R C; Yang, Y; Xie, Y; Tang, J; Shi, Z Y

    2017-12-01

    Comparison of clinical efficacies between coracoclavicular ligament reconstruction using autologous gracilis tendon with suture anchor and clavicular hook plate for the treatment of acute Neer type II distal clavicle fracture. Both coracoclavicular reconstruction with autologous gracilis tendon and clavicular hook plate could achieve satisfactory results for treating acute Neer type II distal clavicle fracture. Acute Neer type II distal clavicle fracture patients enrolled in this prospective randomized study were divided into the coracoclavicular ligament reconstruction group (using autologous gracilis tendon and suture anchor) and the hook plate group. Clinical outcomes were evaluated by shoulder X-ray, forward flexion, abduction and external rotation angle, Constant-Murley shoulder score and pain Visual Analogue Scale (VAS) at each follow-up for up to 24 months. The current study enrolled a total of 42 acute Neer type II distal clavicle fracture patients attended our hospital from March 2010 to December 2013. All patients had achieved complete healing and followed up for an average of 26 months (range, 24-38 months). At 3-month and 6-month follow-ups, Constant-Murley score in the ligament reconstruction group was significantly higher (93.8±2.6 vs. 88.7±8.7; 95.9±2.7 vs. 93.0±7.0, P<0.05), while VAS score was poorer than those in the hook plate group (1.6±0.8 vs. 2.5±1.9; 1.1±1.0 vs. 1.6±1.7, P<0.05). Reconstruction with autologous gracilis tendon improved VAS pain score in early postoperation follow-up; while Constant-Murley score and VAS score were significantly improved in the hook plate group after the implant was removed. These suggested that both coracoclavicular reconstruction with autologous gracilis tendon and clavicular hook plate could achieve satisfactory results. Level II, low-powered prospective randomized trial. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Outcomes of surgery for acromioclavicular joint dislocation using different angled hook plates: a prospective study.

    PubMed

    Xu, Ding; Luo, Peng; Chen, Jukun; Ji, Liefeng; Yin, Luxu; Wang, WeiKang; Zhu, Jiang

    2017-12-01

    Hook plate fixation is widely used to treat acromioclavicular joint dislocation. However, there are many post-operative complications affecting the effect of treatment. The aim of this study is to evaluate the efficacy of the clavicular hook plate with different hook angles as a method of treatment in AC joint dislocation, and to guide the clinical application of hook plate. We prospectively analysed 54 patients who were diagnosed with AC joint dislocation and treated with hook plate fixation by different hook angles. The patients were randomised into three groups: the -20° < AHP < 0° group, the 20° > AHP > 0° group and the 40° > AHP > 20° group. All patients were required to conform to regular follow-up post-operatively. Routine imaging to the shoulder was obtained to evaluate maintenance of the dislocation and the implant. Constant-Murley criteria were used to evaluate functional results. There were 19 patients in the -20° < AHP < 0° group, with one lost to follow-up, 22 patients in the 20° > AHP > 0° group, with two male patients lost to follow-up, and one female patient excluded because of no follow-up consent, and 19 patients in the 40° > AHP > 20° group, with one female and one male patient lost to follow-up. The Constant score was 61.8 ± 12.8, 74.7 ± 9.2 and 70.7 ± 9.4 before implant removal, and 78.8 ± 8.3, 87.1 ± 6.4 and 85.0 ± 6.1 after implant removal in the -20° < AHP < 0°, 20° > AHP > 0° and 40° > AHP > 20° groups, respectively. The functional results of the 20° > AHP > 0° and 40° > AHP > 20° groups were significantly better than the -20° < AHP < 0° group (P < 0.05), but the functional results of the 20° > AHP > 0° and 40° > AHP > 20° groups were not statistically significant. The CCD was 98.1 ± 4.8%, 107.5 ± 5.1% and 105.5 ± 4.1% before implant removal, and 98.8 ± 4.6%, 108.3 ± 4.8% and 107.2 ± 3.3% after implant removal in the

  15. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Güngör, Mustafa

    2016-10-01

    The aim of this study was to analyze the clinical and functional results of hook plate fixation in Neer type 2 distal clavicle fractures. We retrospectively analyzed 16 patients (11 males, 5 females) who were diagnosed with Neer type 2 distal clavicle fractures and treated with hook plate fixation between 2013 and 2014. Mean age was 38 (range: 27-61), and mean follow-up time was 14.3 (range: 12-18) months. Complications seen on radiographs were implant failure and subacromial osteolysis. The clinical results were evaluated with modified UCLA (University of California Los Angeles) scoring system. Bone union was achieved in all patients at the end of the first 4 months. Mean modified UCLA score was 32.75 (range 31-35). In 12 patients (68%), the implants had to be removed due to complications. After removal, the complaints regressed and shoulders' range of motion increased. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate are good in terms of fracture union and function. The major disadvantage of the method was the requirement of early implant removal due to the hardware related complications and good results can be achieved only after plate removal. Optimizing the length of hook plate may lower the rate of complications. Level IV, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  16. [Comparison of double titanium plate and clavicular hook plate for the treatment of Neer II distal clavicular fracture].

    PubMed

    Xu, Qian; Wang, Qiang-Mao; He, Jian-Fei; Sun, Wei-Guo; Chen, Xian-Wei

    2016-12-25

    To compare clinical efficacy of double titanium plate and clavicular hook plate for the treatment of Neer II distal clavicular fracture. From April 2013 to June 2015, 42 patients with Neer II distal clavicle fractures were non-randomly selected, including 25 males and 17 females. All patients were fresh closed fractures. Twenty patients were treated with double titanium plate with tight rope(group A), including 11 males and 9 females aged from 16 to 49 years old with an average age of(33.8±10.7) years;the time from injury to operation ranged from 2 to 5 days with an average of (3.5±1.8) days. Twenty-two patients were treated with clavicle hook plate(group B), including 14 males and 8 females aged from 27 to 53 years old with an average age of (37.7±9.9) years;the time from injury to operation ranged from 2 to 5 days with an average of (3.1±2.0) days. Operative time, blood loss, hospital stays and postoperative complications were observed and compared; fracture healing were compared among preoperative, postoperative at 1, 3 and 6 months; VAS and ASES scoring were used to evaluate shoulder function. All patients were followed up from 6 to 12 months with an average of 7.2 months. All incisions were healed at stage I. Blood loss in group A were less than that of group B( P <0.05); while there were no significant difference in hospital stays and operative time between two groups. No shoulder pain occurred in group A, 4 cases occurred shoulder pain in group B, and had significant difference. Fracture healing time ranged from 3 to 6 months with an average of 4.3 months. VAS score and ASES score in group A were higher than that of group B in pain, function and total score. Compared with clavicle hook plate, double titanium plate has advantages of shorter incision wound, less bleeding and simply operation, less complications, and could avoid pain for removing internal fixation. Over reduction of acromioclavicular joint during operation does not affect its superior

  17. [Clavicular hook plate combined with suture anchor for the treatment of type Tossy III chronic acromioclavicular dislocation].

    PubMed

    Xu, Zhi-Bin; Wang, Jin

    2014-05-01

    To observe the clinical effects of clavicular hook plate combined with suture anchor in treating type Tossy III chronic acromioclavicular dislocation. From January 2008 to December 2012,18 patients with type Tossy III chronic acromioclavicular dislocation were treated with clavicular hook plate and suture anchor. There were 12 males and 6 females, aged from 20 to 56 years old with an average of 31.5 years. Ten cases were left dislocation and 8 cases were right dislocation. Operation time was 3 weeks to 4 months after injury with a mean of 1.8 months. Functional exercise was adopted 2 weeks after operation. And Karlsson standard was used to evaluate curative effect. All patients were followed up for 6 to 24 months with an average of 16 months. According to Karlsson standard, 17 cases were excellent and 1 was poor. Clavicular hook plate combined with suture anchor can repair conoid ligament and trapezoid ligament in treating type Tossy III chronic acromioclavicular dislocation, and had advantages of simple operation, less trauma, stable fixation, it can obtain satisfactory effects.

  18. Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview

    PubMed Central

    2012-01-01

    Background The clavicle hook plate achieves like most other operative techniques, a high percentage of union and a low percentage of complications however concerns about long term complications still exist, particularly the involvement of the acromioclavicular joint. Methods To evaluate the results and long term effects in use of this plate we performed a retrospective analysis with a mean follow up of 65 months (5.4 years) of 28 consecutive patients with acute displaced lateral clavicle fractures, treated with the clavicle hook plate. Results Short term functional results in all patients were good to excellent. All but one patient had a united fracture (96%). Nine patients (32%) developed impingement symptoms and in 7 patients (25%) subacromial osteolysis was found. These findings resolved after plate removal. Twenty-four patients were re-evaluated at a mean follow-up period of 5.4 years. The Constant-Murley score was 97 and the DASH score was 3.5. Four patients (14%) developed acromioclavicular joint arthrosis of which one was symptomatic. Three patients (11%) had extra articular ossifications of which one was symptomatic. There was no relation between the impingement symptoms, subacromial osteolysis and development of acromioclavicular joint arthrosis or extra articular ossifications. Conclusions The clavicle hook plate is a good primary treatment option for the acute displaced lateral clavicle fracture with few complications. At mid term the results are excellent and no long term complications can be addressed to the use of the plate. PMID:22236647

  19. Two fault tolerant toggle-hook release

    NASA Technical Reports Server (NTRS)

    Graves, Thomas Joseph (Inventor); Brown, Christopher William (Inventor)

    1991-01-01

    A coupling device is disclosed which is mechanically two fault tolerant for release. The device comprises a fastener plate and fastener body, each of which is attachable to a different one of a pair of structures to be joined. The fastener plate and body are coupled by an elongate toggle mounted at one end in a socket on the fastener plate for universal pivotal movement thereon. The other end of the toggle is received in an opening in the fastener body and adapted for limited pivotal movement therein. The toggle is adapted to be restrained by three latch hooks arranged in symmetrical equiangular spacing about the axis of the toggle, each hook being mounted on the fastener body for pivotal movement between an unlatching non-contact position with respect to the toggle and a latching position in engagement with a latching surface of the toggle. The device includes releasable lock means for locking each latch hook in its latching position whereby the toggle couples the fastener plate to the fastener body and means for releasing the lock means to unlock each said latch hook from the latch position whereby the unlocking of at least one of the latch hooks from its latching position results in the decoupling of the fastener plate from the fastener body.

  20. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    PubMed

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  1. [EFFECTIVENESS COMPARISON OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION BETWEEN BY AUTOLOGOUS AND ALLOGENEIC TENDON GRAFTS COMBINED WITH HOOK PLATE FIXATION FOR TREATING ACROMIOCLAVICULAR JOINT DISLOCATION].

    PubMed

    Yin, Fei; Sun, Zhenzhong; Wei, Xuming; Liu, Xueguang; Zhou, Ming; Zhuang, Yin; Song, Sheng

    2016-05-08

    To compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. Thirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A ( n =17), and with allogeneic tendon graft combined with hook plate fixation in group B ( n =16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation ( P >0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. The operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B ( P <0.05). There was no significant difference in hospitalization time ( t =1.046, P =0.316). The incisions healed by first intention, and hook plate was removed after 3 months. The mean follow-up time was 21.3 months (range, 19-34 months) in group A and was 23.7 months (range, 18-37 months) in group B. X-ray examination showed no osteolysis. There was no significant difference in gap of acromiocavicular between 2 groups at preoperation, 1 week after operation, and last follow-up ( P >0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups ( P >0

  2. Arthroscopic-assisted Locking Compression Plate clavicular hook fixation for unstable fractures of the lateral end of the clavicle: a prospective study

    PubMed Central

    Lee, Kwang Won; Kim, Kap Jung; Kim, Yong In; Kwon, Won Cho; Choy, Won Sik

    2009-01-01

    The aim of this prospective study was to assess the clinical outcomes of an unstable fracture of the lateral end of the clavicle treated with an arthroscopic-assisted locking compressive plate (LCP) clavicular hook plate. Twenty-three patients underwent arthroscopic assisted LCP clavicular hook plate fixation for these fractures. All patients achieved clinical and radiological union over a mean of 4.2 months (range, 3.4–5 months). Four patients (17%) showed some degree of acromial osteolysis. Three patients (13%) showed radiological signs of arthrosis of the acromioclavicular joint. In one patient, a second fracture (stress) was observed between the medial two screws of the plate without an additional injury. Five patients (22%) showed subacromial bursitis on dynamic ultrasonography. The mean Constant and Murley score was 91 points (range, 81–98). The average level of pain in the shoulder at rest and on abduction was 1 (range, 0–2) and 2.4 (range, 0–4), respectively. Based on our experience, arthroscopic-assisted LCP hook plate fixation for the treatment of unstable fractures of the lateral end of the clavicle is not without complications. However, it is an acceptable alternative method that is easy to apply with good results. Furthermore, it prevents rotator cuff impingement, allows early mobilisation and maintains the acromioclavicular joint biomechanics. PMID:19998033

  3. Acute high-grade acromioclavicular joint injuries: quality of life comparison between patients managed operatively with a hook plate versus patients managed non-operatively.

    PubMed

    Natera Cisneros, Luis Gerardo; Sarasquete Reiriz, Juan

    2017-04-01

    Surgical indication for acromioclavicular joint (ACJ) injuries still represents a reason for shoulder and trauma debate. In high-grade injuries, surgery is advocated because some of the non-operatively managed patients may have persistent shoulder pain that could make them unable to return to their previous activity. It has been shown that many of the patients with high-grade ACJ injuries that are managed non-operatively involve the development of scapular dyskinesis, situation that may result in loss of strength and weakness. On the other side, it has been widely reported that the period while the hook plate is present involves functional limitations and pain. The purpose of this study was to compare the quality of life (QoL) of patients with acute high-grade ACJ injuries (Rockwood grade III-V), managed operatively with a hook plate versus the QoL of patients managed non-operatively, 24 months or more after shoulder injury. Patients with acute high-grade ACJ injuries managed operatively (hook plate) or non-operatively, between 2008 and 2012 were included. The QoL was evaluated by means of the Health Survey questionnaire (SF36), the Visual Analogue Scale (VAS) for pain, the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, the Constant score and the Global Satisfaction (scale from 0 to 10) assessed at the last follow-up visit. The presence of scapular dyskinesis was assessed. Comparison between groups was made. Thirty-two patients were included: 11 hook plate-group (PLATE group) (5 Rockwood III and 6 V) and 21 conservative-group (CONS group) (4 Rockwood III and 17 V). The mean age was 41 [19-55] years old for the PLATE group and 38 [19-55] for the CONS group (p = 0.513). The mean follow-up was 32.50 ± 11.64 months for the PLATE group and 34.77 ± 21.98 months for the CONS group (p = 0.762). The mean results of the questionnaires assessed at the last follow-up visit were: (1) physical SF36 score (PLATE group 53.70 ± 4.33 and CONS group

  4. Clinical therapeutic effects of AO/ASIF clavicle hook plate on distal clavicle fractures and acromioclavicular joint dislocations.

    PubMed

    Dou, Qingjun; Ren, Xiaofeng

    2014-07-01

    The aim of this study was to evaluate the security and effectiveness of AO/ASIF clavicle hook plate in the treatment of distal clavicle fractures and acromioclavicular joint dislocations. One hundred patients with distal clavicle fractures and acromioclavicular joint dislocations who were admitted in our hospital from January 2012 to January 2013 were selected as the study subjects. They were then randomly divided into a control group and an observation group (n=50). The observation group was treated with AO/ASIF clavicle hook plates, and the control group was treated with Kirschner-wire tension bands. The outcomes were recorded and compared. The JOA scores of the two groups were similar before surgery (P>0.05). The two groups both had obviously increased JOA scores in the postoperative 6th and 12th weeks, and the score in the postoperative 12th week was higher. There were statistically significant intra-group differences (P<0.05). The postoperative 6th-week and 12th-week JOA scores of the observation group were (83.2±1.8) and (97.4±1.5) respectively, and those of the control group were (71.6±2.2) and (82.3±2.6) respectively, with statistically significant inter-group differences (P<0.05). Significantly more patients in the observation group (100%) were evaluated as excellent or good outcomes after fixation than those in the control group (60%). After removal of the surgical apparatus, the recurrence rates of bone fracture and joint dislocation in the observation group were significantly lower than those of the control group (P<0.05). AO/ASIF clavicle hook plate functioned more effectively than Kirschner-wire tension band in clinical treatment of distal clavicle fractures and acromioclavicular joint dislocations. The former protocol enjoyed small incisions, firm fixation and early shoulder mobility. Therefore, it is a safe and effective surgical method that is worthy of being widely applied in clinical practice.

  5. Morphometric analysis of the proximal ulna using three-dimensional computed tomography and computer-aided design: varus, dorsal, and torsion angulation.

    PubMed

    Yong, Woon Jae; Tan, Jun; Adikrishna, Arnold; Lee, Hyun Joo; Jung, Jin Woo; Cho, Dong-Woo; Jeon, In-Ho

    2014-10-01

    The proximal ulna, particularly the course of the posterior border, has a complex three-dimensional (3D) morphology which has been highlighted recently due to its clinical relevance in relation to surgical treatments. 3D computed tomography (CT) reconstruction and computer-aided design (CAD) based software can help to visualize the complex anatomy and thus aid the investigation of the more detailed morphology of the proximal ulna. In our current study, 3D CT reconstruction images of 20 cadavers were imported into the 3D CAD program. Three morphologic angle parameters of the proximal ulna were measured including the dorsal, varus and torsion angulation. The torsion angulation was measured using the flat spot of olecranon dorsal aspect. We measured the total length of the ulna and the distance between the olecranon tip and the apex of dorsal and varus angulation. Furthermore, the thickness of olecranon was also measured for all the specimens. The results showed that the mean dorsal, varus, and torsion angulation was 4.3° (range 2.6°-5.9°), 12.1° (range 7.9°-17.6°), and 22.5° (range 16.6°-30.5°), respectively. The average length ratio of the dorsal and varus angulation apex to the total ulnar length was 26.4 % (range 19.8-30.7 %) and 32.7 % (range 27.5-37.5 %), respectively. The average of olecranon thickness at the proximal tip, mid-olecranon fossa, and at coronoid tip level was 17.8 mm (range 14.1-22.8 mm), 19.7 mm (range 15.8-23.1 mm), and 35.1 mm (range 27.9-41.8 mm), respectively. In conclusion, variations in the proximal ulna have to be considered when anatomically contoured dorsal plates are applied. Knowledge of the 3D morphologic anatomy of the proximal ulna would provide important information on fracture reductions, and the design of a precontoured dorsal plate or a prosthetic ulnar stem.

  6. [EFFECTIVENESS OF CLAVICULAR HOOK PLATE COMBINED WITH TRAPEZIUS MUSCLE FASCIA FOR RECONSTRUCTION OF ACROMIOCLAVICULAR AND CORACOCLAVICULAR LIGAMENTS TO TREAT COMPLETE ACROMIOCLAVICULAR JOINT DISLOCATION].

    PubMed

    Wang, Chaoliang; Wang, Yingzhen; Zhu, Tao; Sun, Xuesheng; Lin, Chu; Gao, Bo; Li, Xinxia

    2015-02-01

    To explore the effectiveness of the clavicular hook plate combined with trapezius muscle fascia for reconstruction of acromioclavicular and coracoclavicular ligaments to treat acute complete acromioclavicular dislocations. Between January 2008 and April 2012, 66 patients with acromioclavicular dislocation were treated with the clavicular hook plate combined with trapezius muscle fascia for reconstruction of acromioclavicular and coracoclavicular ligaments in 32 cases (experimental group) and with the clavicular hook plate in 34 cases (control group). There was no significant difference in gender, age, injured side, the cause of injury, and the time from injury to operation between 2 groups (P > 0.05). Visual analogue scale (VAS), Constant shoulder scores, and coracoid clavi-cledistance (CC. Dist) were measured at preoperation and at 2 years after operation. Signal/noise quotiem (SNQ) was measured by MRI at 2 years after operation. The operation complications were observed. The patients of 2 groups obtained primary healing of incision. The morbidity of complication in experimental group (12.5%, 4/32) was significantly lower than that in control group (91.2%, 31/34) (Χ2 = 40.96, P = 0.00). All the cases were followed up 2.8 years on average (range, 2 to 4 years). VAS scores and CC.Dist significantly decreased at 2 years after operation when compared with preoperative values in the 2 groups (P < 0.05). VAS scores and CC.Dist of the experimental group were significantly lower than those in the control group (P < 0.05). According to Constant shoulder scores at 2 years after operation, the results were excellent in 19 cases, good in 11 cases, and general in 2 cases with an excellent and good rate of 93.75% in the experimental group; the results were excellent in 7 cases, good in 8 cases, general in 16 cases, and poor in 3 cases with an excellent and good rate of 44.11% in the control group; and significant difference was shown between 2 groups (t = 2.30, P = 0.03). SNQ

  7. Comparison of hook plate with versus without double-tunnel coracoclavicular ligament reconstruction for repair of acute acromioclavicular joint dislocations: A prospective randomized controlled clinical trial.

    PubMed

    Yin, Jian; Yin, Zhaoyang; Gong, Ge; Zhu, Chao; Sun, Chao; Liu, Xinhui

    2018-06-01

    This study was designed to compare the surgical outcomes of a hook plate with double-tunnel coracoclavicular (CC) ligament reconstruction by conjoined tendon transfer versus single hook plate surgery for the repair of acute type of Rockwood type III and V acromioclavicular (AC) joint dislocations. The study cohort included 62 patients with acute (within 6 weeks after trauma) Rockwood type III and V AC joint dislocations who underwent surgery from February 2012 to September 2015. The patients were randomly allocated to the ligament reconstruction group (LR group, n = 31) or the single hook plate group (HP group, n = 31). In both groups, reduction of the AC joint by hook plate and repair of the ruptured AC ligament with absorbable Vicryl sutures were performed homoplastically. The lateral half of the short tendon of the biceps brachii muscle and the lateral half of the flexor tendon were used to reconstruct the trapezoid and conoid ligaments, respectively. Differences in surgical duration, intraoperative blood loss, incision length, and total cost were compared between the two groups. Furthermore, the preoperative and postoperative visual analogue score (VAS), postoperative American Shoulder and Elbow Surgeons (ASES) score, Constant-Murley score (CMS), Karlsson score, complication rates, and patient satisfaction at the last follow-up were compared to evaluate the curative effects of the surgical treatments. Magnetic resonance imaging (MRI) after hook plate removal was used to evaluate the reconstructed ligaments and tendon-bone interface. In total, 25 patients in the LR group and 26 in the HP group completed the follow-up. There were no statistically significant differences in age, sex, Rockwood type, placing time, total cost, and follow-up duration between the LR and HP groups (p > 0.05). However, as compared with the HP group, the surgical duration and incision length were longer in the LR group (92.08 ± 19.25 vs. 56.54 ± 21.29 min and 13

  8. Management of comminuted proximal ulna fracture-dislocations using a multiplanar locking intramedullary nail.

    PubMed

    Edwards, Scott G; Argintar, Evan; Lamb, Joshua

    2011-06-01

    Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.

  9. Cooling system for three hook ring segment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Christian X.; Eng, Darryl; Lee, Ching-Pang

    2014-08-26

    A triple hook ring segment including forward, midsection and aft mounting hooks for engagement with respective hangers formed on a ring segment carrier for supporting a ring segment panel, and defining a forward high pressure chamber and an aft low pressure chamber on opposing sides of the midsection mounting hook. An isolation plate is provided on the aft side of the midsection mounting hook to form an isolation chamber between the aft low pressure chamber and the ring segment panel. High pressure air is supplied to the forward chamber and flows to the isolation chamber through crossover passages in themore » midsection hook. The isolation chamber provides convection cooling air to an aft portion of the ring segment panel and enables a reduction of air pressure in the aft low pressure chamber to reduce leakage flow of cooling air from the ring segment.« less

  10. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    PubMed

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  11. Clavicle hook plate fixation for distal-third clavicle fracture (Neer type II): comparison of clinical and radiologic outcomes between Neer types IIA and IIB.

    PubMed

    Lee, Wonyong; Choi, Chong-Hyuk; Choi, Yun-Rak; Lim, Kyung-Han; Chun, Yong-Min

    2017-07-01

    The purpose of this study was to investigate clinical and radiologic outcomes of clavicle hook plate fixation for distal-third clavicle fracture (Neer type II) and to compare the clinical and radiologic outcomes and complications between Neer type IIA and type IIB. We retrospectively reviewed 35 patients who underwent open reduction and internal fixation with AO hook locking compression plate (LCP) for distal clavicle fracture, including 13 patients with Neer type IIA and 22 patients with type IIB. Visual analog scale pain score, shoulder scores (subjective shoulder value, University of California-Los Angeles shoulder score, American Shoulder and Elbow Surgeons score), and active range of motion were evaluated to determine clinical outcome. Coracoclavicular distance was measured, and that of the injured side at last follow-up was compared with that of the uninjured side to evaluate radiologic outcomes. AO hook LCP fixation for distal-third clavicle fracture (Neer type II) produced satisfactory radiologic outcomes, including high union rates (100%) and coracoclavicular distance maintenance, as well as satisfactory clinical outcomes, including visual analog scale score for pain, shoulder scores (subjective shoulder value, University of California-Los Angeles shoulder score, American Shoulder and Elbow Surgeons score), and active range of motion. There were no significant differences between Neer type IIA and type IIB. With regard to complications, 22.9% of patients experienced shoulder stiffness and 17.1% had subacromial erosion; however, there were no significant differences between the 2 groups. The AO hook LCP is a suitable choice for Neer type IIA and type IIB distal-third clavicle fracture fixation. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Radius morphology and its effects on rotation with contoured and noncontoured plating of the proximal radius.

    PubMed

    Rupasinghe, Shavantha L; Poon, Peter C

    2012-05-01

    The radius has a sagittal bow and a coronal bow. Fractures are often treated with volar anterior plating. However, the sagittal bow is often overlooked when plating. This study looks at radial morphology and the effect of plating the proximal radius with straight plates and then contoured plates bowed in the sagittal plane. We report our findings and their effect on forearm rotation. Morphology was investigated in 14 radii. Attention was paid to the proximal shaft of the radius and its sagittal bow; from this, 6-, 7-, and 8-hole plates were contoured to fit this bow. A simple transverse fracture was then made at the apex of this bow in 23 cadaver arms. Supination and pronation were compared when plating with a straight plate and a contoured plate. Ten cadavers underwent ulna plating at the same level. The effect on rotation of fractures plated in the distal-third shaft was also measured. A significant reduction in rotation was found when a proximal radius fracture was plated with a straight plate compared with a contoured plate: 10.8°, 12.8°, and 21.7° for 6-, 7-, and 8-hole plates, respectively (P < .05). Forearm rotation was decreased further when a longer plate was used. Ulna or distal shaft plating did not reduce rotation. This study has shown a significant sagittal bow of the proximal shaft of the radius. Plating this with contoured plates in the sagittal plane improves rotation when compared with straight plates. Additional ulna plating is not a source of reduced forearm rotation. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Post-osteomyelitic-acquired radial club hand deformity in children treated by centralization of ulna.

    PubMed

    Meena, Dinesh Kumar

    2017-01-01

    Radial club hand deformity acquired post haematogenous osteomyelitis of radius bone is a very rare disease. Resulting in functional and cosmetic deficit of upper limb which is similar to congenital cases. For a long-time various surgeons attempted to reconstruct the deformity by bone grafting, plating, Ilizarov, monorail external fixator, callus distraction and so on. Keeping in mind that creating single bone forearm we proposed centralization of ulna on wrist to correct the deformity. In our institute, we conducted a rare study involving small number of patients ( n = 5), between February 2013 and November 2106. The study participants comprised four male children and one female child whose average age was 1.8 months. Participant inclusion criteria were no active infection, no distal end of radius (cartilage remnant) and only haematogenous osteomyelitis. Exclusion criteria were congenital radial club hand and active infection. Decrease in the angle of radial deviation (radiologically) preoperatively from 54° to 5° and angle of volar flexion from 34° to 4° were measured. Preoperatively no ulnar angulations were observed. Length of ulna remains similar to the opposite side. No neurovascular complication noted and full range of movement regained. Our case series is unique in terms of massive bone loss, that is, distal metaphysic and epiphysis, so we followed the statement of Ono et al. and did centralization of ulna over carpus and achieved good functional and cosmetic outcome at the cost of loss of motion at the wrist, concluding that treatment is primarily considered as salvage only.

  14. Comparison of the Tight Rope Technique and Clavicular Hook Plate for the Treatment of Rockwood Type III Acromioclavicular Joint Dislocation.

    PubMed

    Cai, Leyi; Wang, Te; Lu, Di; Hu, Wei; Hong, Jianjun; Chen, Hua

    2018-06-01

    Acromioclavicular joint dislocation is one of the most common shoulder problems and may lead to instability or degenerative changes. The aim of this study was to compare the clinical outcomes of the Tight Rope system and clavicular hook plate for Rockwood type III acromioclavicular joint dislocation in adults. This was a prospective, randomized study in a hospital setting. From January 2012 to December 2014, 69 patients with type III injury were reviewed. Patients were randomly divided into two groups: Group A was treated using the TightRope system and Group B with the clavicular hook plate. All participants were followed up for 12 months. Clinical outcomes, radiological results and postoperative complications were recorded. The length of incision was significantly shorter in Goup A than that in Group B. The blood loss of surgery was significantly less in the Group A. Significant difference could be found between the two groups regarding the Visual Analogue Scale scores one day after surgery, at the 3 and 12 months follow-up. There were no differences according to the improvement of the Constant-Murley score and the coracoclavicular distance between the groups. The two groups have similar clinical and radiological outcomes. Both treatments could relieve the pain of dislocation, improve the function of Acromioclavicular joint and rectify the coracoclavicular distance measured in plain films. However, the TightRope system exhibited some advantages in terms of length of incision, blood loss of surgery, the pain postoperatively and no need for a second surgery.

  15. [Application of lateral malleolus hook-plate in treatment of stage II supination-adduction type medial malleolus fracture].

    PubMed

    Chen, Yu; Zhang, Hui; Huang, Fuguo; Xiang, Zhuo; Fang, Yue; Liu, Lei; Cen, Shiqiang

    2014-09-01

    To investigate the application of lateral malleolus hook-plate for the treatment of stage II supination-adduction type medial malleolus fractures. Between January 2011 and June 2013, 21 patients with stage II supination-adduction type ankle fractures were treated with lateral malleolus hook-plate, including 12 males and 9 females with an average age of 55.5 years (range, 27-65 years). The injury causes were sprain in 17 cases and traffic accident in 4 cases. The mean time between injury and admission was 12.4 hours (range, 2-72 hours). The tibial distal medial articular surface collapse was found in 7 cases by CT examination and in 3 cases by X-ray film. Of 21 cases, there were 12 cases of low transverse fractures of lateral malleolus, 7 cases of short oblique fractures of lateral malleolus, and 2 cases of ankle joint lateral collateral ligament injury without fractures of lateral malleolus. After operation, the clinical outcome was evaluated according to the talus-leg angle, the recovery of Coin-sign continuity, inside-outside and top ankle gap, talus slope, American Orthopedic Foot and Ankle Society (AOFAS) score, Olerud-Molander score, Kofoed evaluation standards, and patient satisfaction. Seventeen cases were followed up 18.7 months on average (range, 12-25 months). Primary healing was obtained in 16 cases except 1 case of delayed healing. Fracture healed at an average of 14.6 weeks (range, 12-16 weeks). All cases achieved anatomical reduction, the continuity of Coin-sign, and consistency of inside and outside joint gap; no talus tilt occurred. There was no complication of reduction loss, loosening or breakage of internal fixation, or osteoarthritis during follow-up. The talus-leg angle of the affected side was significantly improved to (83.4 ± 1.8)° at 1 week after operation from preoperative (74.8 ± 7.1)° (t = 5.370, P = 0.000), but no significant difference was found when compared with normal side (83.8 ± 2.3)° (t = 0.676, P = 0.509). The AOFAS score

  16. Stress fracture of ulna due to excessive push-ups.

    PubMed

    Meena, Sanjay; Rastogi, Devarshi; Solanki, Bipin; Chowdhury, Buddhadev

    2014-01-01

    Stress fractures are most common in the weight-bearing bones of the lower extremities and spine, but are rarely found in non-weight-bearing bones of the body. Stress fracture of the ulna is extremely rare. We report a case of complete stress fracture of ulna caused due to excessive push ups in a young athlete. Conservative management was successful in healing of fracture and returning this patient back to his previous activity level. Physician should have high index of suspicion, whenever they encounter a young athlete complaining of forearm pain.

  17. Lunar crane hook

    NASA Technical Reports Server (NTRS)

    Cash, John Wilson, III; Cone, Alan E.; Garolera, Frank J.; German, David; Lindabury, David Peter; Luckado, Marshall Cleveland; Murphey, Craig; Rowell, John Bryan; Wilkinson, Brad

    1988-01-01

    The base and ball hook system is an attachment that is designed to be used on the lunar surface as an improved alternative to the common crane hook and eye system. The design proposed uses an omni-directional ball hook and base to overcome the design problems associated with a conventional crane hook. The base and ball hook is not sensitive to cable twist which would render a robotic lunar crane useless since there is little atmospheric resistance to dampen the motion of an oscillating member. The symmetric characteristics of the ball hook and base eliminates manual placement of the ball hook into the base; commonly associated with the typical hook and eye stem. The major advantage of the base and ball hook system is it's ease of couple and uncouple modes that are advantages during unmanned robotic lunar missions.

  18. Topographical Anatomy of the Distal Ulna Attachment of the Radioulnar Ligament.

    PubMed

    Shin, Won-Jeong; Kim, Jong-Pil; Yang, Hun-Mu; Lee, Eun-Young; Go, Jai-Hyang; Heo, Kang

    2017-07-01

    The deep component of the distal radioulnar ligament provides translational stability and rotational guidance to the forearm. However, controversy exists regarding the importance of this structure as well as the nature of its attachment to the distal ulna. We aimed to evaluate the topographic anatomy of the distal ulna attachment of both the superficial and the deep components of the radioulnar ligament and to assess the relationship between its internal and its external morphometry. Thirteen human distal ulnae attached by ulnar part of the distal radioulnar ligament were scanned using micro-computed tomography and reconstructed in 3 dimensions. In addition, the distal radioulnar ligaments were examined under polarized light microscopy to determine the histological characteristics of collagen contained within the ligaments. The deep limbs have broad marginal insertions at the fovea, whereas the superficial limbs have a circular and condensed insertion to the ulnar styloid. The center of the deep limb was separated from the base of the ulnar styloid by a mean of 2.0 ± 0.76 mm, and this distance was positively correlated with the width of the ulnar styloid. The mean distance between the center of the ulnar head and the center of the fovea was 2.4 ± 0.58 mm. The proportion of collagen type I was lower in the deep limb than in the superficial limb. This new observation of the footprint of the radioulnar ligament in the distal ulna indicates that the deep limb may serve as an internal capsular ligament of the distal radioulnar joint, whereas the superficial limb as the external ligament. Knowledge of the topographic anatomy of the radioulnar ligament's attachment to the distal ulna may provide a better understanding of distal radioulnar ligament-related pathologies. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures.

    PubMed

    Erdle, Benjamin; Izadpanah, Kaywan; Jaeger, Martin; Jensen, Patrizia; Konstantinidis, Lukas; Zwingmann, Jörn; Südkamp, Norbert P; Maier, Dirk

    2017-05-01

    Controversy exists on optimal operative treatment of vertically unstable Neer IIB lateral clavicle fractures. Aim of this study was to analyse and compare clinical and radiological results and complications of locking plate osteosynthesis (LPO) versus hook plate osteosynthesis (HPO) with acromioclavicular joint (ACJ) stabilization. The hypothesis was, that HPO would recreate coracoclavicular stability more effectively and potentially lead to a superior outcome. This retrospective, observational cohort study included 32 patients (19 HPO, 13 LPO) with a mean age of 44.1 ± 14.2 years at surgery. The mean follow-up period was 54.2 months (range 25.2-111.4 months). Besides standard radiography, bilateral coracoclavicular distances were assessed by means of preoperative and follow-up stress radiographs after implant removal. Clinical outcome measures included the Constant score (CS), the Oxford shoulder score (OSS), the subjective shoulder value (SSV) and the Taft score (TS). Bone union occurred in all but one patient and proved to occur delayed in five patients (15.6%). Radiographical healing required a mean of 4.2 ± 4.0 months irrespective of the type of osteosynthesis. At follow-up, mean coracoclavicular distance was increased by 34% (±36) without significant differences between both groups. HPO patients obtained a significantly lower TS (HPO: 9.5 ± 1.5 points, LPO: 11.1 ± 1.3 points; p = 0.005). Other mean score values did not differ (CS: 90.1 ± 7.4 points, OSS: 43.2 ± 9.2 points, SSV: 91.1 ± 14.7%). Sixteen patients (50.0%) experienced complications. Overall prevalence of complications was significantly higher in the HPO group (p = 0.014). Both HPO and LPO were equally effective in relation to restoration of vertical stability, overall functional outcome and fracture consolidation in treatment of Neer IIB fractures. Contrary to our hypothesis, HPO was not associated with superior recreation of the coracoclavicular

  20. Hooke's figurations: a figural drawing attributed to Robert Hooke.

    PubMed

    Hunter, Matthew C

    2010-09-20

    The experimental philosopher Robert Hooke (1635-1703) is known to have apprenticed to the leading painter Peter Lely on his first arrival in London in the late 1640s. Yet the relevance of Hooke's artistic training to his mature draughtsmanship and identity has remained unclear. Shedding light on that larger interpretive problem, this article argues for the attribution to Hooke of a figural drawing now in Tate Britain (T10678). This attributed drawing is especially interesting because it depicts human subjects and bears Hooke's name functioning as an artistic signature, both highly unusual features for his draughtsmanship. From evidence of how this drawing was collected and physically placed alongside images by leading artists in the early eighteenth century, I suggest how it can offer new insight into the reception of Hooke and his graphic work in the early Enlightenment.

  1. Sex determination from the radius and ulna in a modern South African sample.

    PubMed

    Barrier, I L O; L'Abbé, E N

    2008-07-18

    With a large number of unidentified skeletal remains found in South Africa, the development of population specific osteometric standards is imperative. Forensic anthropologists need to have access to a variety of techniques to establish accurate demographic profiles from complete, fragmentary and/or commingled remains. No research has been done on the forearm of African samples, even though these bones have been shown to exhibit sexual dimorphism. The purpose of this paper is to develop discriminant function formulae to determine sex from the radius and ulna in a South African population. The sample consisted of 200 male and 200 female skeletons from the Pretoria Bone (University of Pretoria) and Raymond A. Dart (Witwatersrand University) collections. Sixteen standard anthropometric measurements were taken from the radius (9) and ulna (7) and subjected to stepwise and direct discriminant function analysis. Distal breadth, minimum mid-shaft diameter and maximum head diameter were the best discriminators of sex for the radius, while minimum mid-shaft diameter and olecranon breadth were selected for the ulna. Classification accuracy for the forearm ranged from 76 to 86%. The radius and ulna can be considered moderate discriminators for determining sex in a South African group. However, it is advised that these formulae are used in conjunction with additional methods to determine sex.

  2. Contact between the acetabulum and dome of a Kerboull-type plate influences the stress on the plate and screw.

    PubMed

    Hara, Katsutoshi; Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-07-01

    We used a three-dimensional finite element method to investigate the conditions behind the Kerboull-type (KT) dome. The KT plate dome was divided into five areas, and 14 models were created to examine different conditions of dome contact with the acetabulum. The maximum stress on the KT plate and screws was estimated for each model. Furthermore, to investigate the impact of the contact area with the acetabulum on the KT plate, a multiple regression analysis was conducted using the analysis results. The dome-acetabulum contact area affected the maximum equivalent stress on the KT plate; good contact with two specific areas of the vertical and horizontal beams (Areas 3 and 5) reduced the maximum equivalent stress. The maximum equivalent stress on the hook increased when the hardness of the bone representing the acetabulum varied. Thus, we confirmed the technical importance of providing a plate with a broad area of appropriate support from the bone and cement in the posterior portion of the dome and also proved the importance of supporting the area of the plate in the direction of the load at the center of the cross-plate and near the hook.

  3. Stature estimation and formulation of based on ulna length in Kurdish racial subgroup.

    PubMed

    Ghanbaril, Kimia; Nazari, Ali Reza; Ghanbari, Ali; Chehrei, Shima

    2016-01-01

    Measuring stature is useful for forensic and anthropometrical sciences. The present study was con- ducted to calculate the stature from ulna length among Kurdish racial subgroup living in Iran. In this study, 50 females aged 19-24 were recruited. The ulna length of subjects was taken indepen- dently on left and right sides using a digital sliding caliper. The height was measured between vertex and floor. The height (Y) was also estimated by linear regression formulas from the length of right (X1) or left side ulna (X2). For right side, Y1 = 59.48 + 4.005 X1 ± 4.09295 (R=0.753); for left side, Y2 = 63.44 +3.887 X2 ± 4.24106 (R=0.731). The derived formulae are population specific and are designed for use in forensic and anthropometric skeletal analysis of Kurdish racial subgroup. These data provide a scientific basis for further investigations on racial subgroups living in Iran.

  4. Comparison of torsional stability of 2 types of split crimpable surgical hooks with soldered brass surgical hooks.

    PubMed

    O'Bannon, Shawn P; Dunn, William J; Lenk, Jason S

    2006-10-01

    The purpose of this in-vitro study was to compare the torsional stability of split crimpable surgical hooks and soldered brass surgical hooks on a rectangular stabilizing archwire. Coated split crimpable hooks (Never-Slip Grip, TP Orthodontics, LaPorte, Ind), ribbed crimpable hooks (TP Orthodontics), and .032-in brass soldered hooks/notched electrodes (Ormco/Sybron Dental Specialties, Orange, Calif) were attached to a 0.019 x 0.025-in stainless steel archwire. The archwire/hook attachment assembly was secured into a dual contact jig and statically mounted to the base of a universal testing machine. The hooks were engaged by a wire loop attached to the upper load cell of the machine, which pulled the wire until the hook was torsionally displaced from the archwire. The mean forces, measured in newtons (N), required to dislodge the hooks were as follows: soldered brass surgical hooks (51.3 +/- 5.2 N), coated split crimpable hooks (49.9 +/- 6.6 N), and ribbed split crimpable hooks (31.3 +/- 5.4 N). Data were analyzed with 1-way ANOVA and Tukey HSD post-hoc tests at alpha = .05. Ribbed split crimpable hooks provided significantly less resistance to torsional displacement than the other types of hooks (P <001). There was no difference between coated split crimpable hooks and soldered brass surgical hooks (P >05). Under the conditions of this study, the results suggest that soldered brass surgical hooks and coated split crimpable hook attachments provide more stability to torsional dislodgement from a rectangular stabilizing archwire than ribbed split crimpable hooks.

  5. Hox11 genes regulate postnatal longitudinal bone growth and growth plate proliferation.

    PubMed

    Pineault, Kyriel M; Swinehart, Ilea T; Garthus, Kayla N; Ho, Edward; Yao, Qing; Schipani, Ernestina; Kozloff, Kenneth M; Wellik, Deneen M

    2015-10-23

    Hox genes are critical regulators of skeletal development and Hox9-13 paralogs, specifically, are necessary for appendicular development along the proximal to distal axis. Loss of function of both Hoxa11 and Hoxd11 results in severe malformation of the forelimb zeugopod. In the radius and ulna of these mutants, chondrocyte development is perturbed, growth plates are not established, and skeletal growth and maturation fails. In compound mutants in which one of the four Hox11 alleles remains wild-type, establishment of a growth plate is preserved and embryos develop normally through newborn stages, however, skeletal phenotypes become evident postnatally. During postnatal development, the radial and ulnar growth rate slows compared to wild-type controls and terminal bone length is reduced. Growth plate height is decreased in mutants and premature growth plate senescence occurs along with abnormally high levels of chondrocyte proliferation in the reserve and proliferative zones. Compound mutants additionally develop an abnormal curvature of the radius, which causes significant distortion of the carpal elements. The progressive bowing of the radius appears to result from physical constraint caused by the disproportionately slower growth of the ulna than the radius. Collectively, these data are consistent with premature depletion of forelimb zeugopod progenitor cells in the growth plate of Hox11 compound mutants, and demonstrate a continued function for Hox genes in postnatal bone growth and patterning. © 2015. Published by The Company of Biologists Ltd.

  6. Fracture through a geode in the proximal ulna.

    PubMed

    Wordsworth, B P; Mowat, A G; Watson, N A

    1984-05-01

    Chronic joint pain in rheumatoid arthritis may mask that from other causes. Stress fractures, particularly in osteoporotic lower limb bones of such patients, are well described but can still cause diagnostic difficulty. These difficulties were highlighted by a case in which an unusual fracture occurred through a geode in the proximal ulna mimicking an exacerbation of synovitis in the elbow joint.

  7. [Case control study on the treatment of acromioclavicular dislocation with Endobutton plates combined with an anchor].

    PubMed

    Hu, Jin-Tao; Lu, Jian-Wei; Fu, Li-Feng

    2016-09-25

    To compare the clinical effect of Endobutton plates combined with an anchor and clavicle hook plate in the treatment of acromioclavicular dislocation. From January 2012 to August 2014, 83 patients with Rockwood type III acromioclavicular dislocation underwent surgical treatments. Among them, 34 patients were treated with Endobutton plate and anchor repair(Endobutton group), including 23 males and 11 females, and the mean age was(39.0±6.3) years old (26 to 51 years old); the average time from injury to operation was(4.1±1.3) days(3 to 7 days);the injured side:14 left, 20 right; the dislocation in 28 patients dues to fall, 6 patients dues traffic accident. There were 49 patients treated with clavicular hook plate(hook plate group), including 33 males and 16 females;the mean age was(37.9±6.3) years old (27 to 53 years old); the average time from injury to operation was(4.1±1.1) days (2 to 7 days);the injured side: 18 left, 31 right;the dislication in 36 patients dues to fall, 13 patients dues traffic accidents. The indexes such as intraoperative bleeding volume, operation time, incision size, postoperative complication and postoperative coracoclavicular space, shoulder joint function, and life quality were compared between two groups. In the hook plate group with 49 patients, the plates in 43 patients were removed at the secondary operation, and 32 patients had shoulder pain or limited active range. Thirty four patients in the Endobutton group had no pain symptoms and limited active range. All the patients did not suffer acromioclavicular dislocation again. There was no significant difference between the two groups in operation time, and intraoperative bleeding volume( P >0.05). The incision length in the hook plate group was longer than that in Endobutton group( P <0.05). The coracoclavicular space of the uninjured and injured side in two groups respectively had no significant differences, and the coracoclavicular space in the injured side between two group had

  8. Getting Hooked on Physics!

    ERIC Educational Resources Information Center

    McHugh, M.; McCauley, V.

    2016-01-01

    A number of papers in this journal have dealt with the idea of using hooks in physics instruction. A hook, as the name suggests, engages students in learning by triggering their attention and interest. Hooks can be any type of pedagogical approach--a question, a demonstration, a puzzle or video. They are generally short and center on the most…

  9. Role of the Dc domain of the bacterial hook protein FlgE in hook assembly and function

    PubMed Central

    Moriya, Nao; Minamino, Tohru; Ferris, Hedda U.; Morimoto, Yusuke V.; Ashihara, Masamichi; Kato, Takayuki; Namba, Keiichi

    2013-01-01

    The bacterial flagellar hook acts as a universal joint to smoothly transmit torque produced by the motor to the filament. The hook protein FlgE assembles into a 55 nm tubular structure with the help of the hook cap (FlgD). FlgE consists of four domains, D0, Dc, D1 and D2, arranged from the inner to the outer part of the tubular structure of the hook. The Dc domain contributes to the structural stability of the hook, but it is unclear how this Dc domain is responsible for the universal joint mechanism. Here, we carried out a deletion analysis of the FlgE Dc domain. FlgEΔ4/5 with deletion of residues 30 to 49 was not secreted into the culture media. FlgEΔ5 and FlgEΔ6 with deletions of residues 40 to 49 and 50 to 59, respectively, still formed hooks, allowing the export apparatus to export the hook-filament junction proteins FlgK and FlgL and flagellin FliC. However, these deletions inhibited the replacement of the FlgD hook cap by FlgK at the hook tip, thereby abolishing filament formation. Deletion of residues 50 to 59 significantly affected hook morphology. These results suggest that the Dc domain is responsible not only for hook assembly but also for FlgE export, the interaction with FlgK, and the polymorphic supercoiling mechanism of the hook. PMID:27493542

  10. Stress analyses of B-52 pylon hooks

    NASA Technical Reports Server (NTRS)

    Ko, W. L.; Schuster, L. S.

    1985-01-01

    The NASTRAN finite element computer program was used in the two dimensional stress analysis of B-52 carrier aircraft pylon hooks: (1) old rear hook (which failed), (2) new rear hook (improved geometry), (3) new DAST rear hook (derated geometry), and (4) front hook. NASTRAN model meshes were generated by the aid of PATRAN-G computer program. Brittle limit loads for all the four hooks were established. The critical stress level calculated from NASTRAN agrees reasonably well with the values predicted from the fracture mechanics for the failed old rear hook.

  11. A Modified Rabbit Ulna Defect Model for Evaluating Periosteal Substitutes in Bone Engineering: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El Backly, Rania M.; IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova; Faculty of Dentistry, Alexandria University, Alexandria

    The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX{sup ®}) membranemore » was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX{sup ®}) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.« less

  12. Survival of foul-hooked largemouth bass (Micropterus salmoides)

    USGS Publications Warehouse

    Pope, K.L.; Wilde, G.R.

    2010-01-01

    We conducted a field experiment to determine the survival rate of foul-hooked (hooked external to the oral cavity) largemouth bass (Micropterus salmoides) caught and released by recreational anglers. Of 42 largemouth bass caught with hard-plastic baits containing three treble hooks, 15 were hooked only within the mouth and 27 had at least one hook penetrating the external surface of the fish (i.e., foul-hooked). There was no difference in survival of mouth-hooked (100%), foul-hooked (100%), or control (100%) largemouth bass.

  13. Melorheostosis of the ulna.

    PubMed

    Abdullah, Shalimar; Pang, Gerry M H; Mohamed-Haflah, Nor Hazla; Sapuan, Jamari

    2011-10-01

    Melorheostosis is a rare osteosclerotic bone dysplasia. It is usually characterized by dull and aching pain, reduced joint motion and contractures. Classic radiograph findings are of undulating cortical hyperostosis along the length of the bone, simulating a "dripping candlewax appearance". We report two cases of melorheostosis of the ulna bone, diagnosed 6 years apart in two different females in their early 20s. Both the patients presented with the characteristic features of dull and aching pain in the forearm and were treated conservatively. However, we misdiagnosed the first case as bone malignancy and subjected the patient to a biopsy. For the second case, with hindsight we made the correct diagnosis based only on the classic clinical history and radiographs. We believe that the discussion of a misdiagnosed case of melorheostosis with salient findings may be important for clinicians and orthopedicians in day-to-day clinical practice. Copyright © 2011. Published by Elsevier B.V.

  14. Getting Hooked on Physics!

    NASA Astrophysics Data System (ADS)

    McHugh, M.; McCauley, V.

    2016-12-01

    A number of papers in this journal have dealt with the idea of using hooks in physics instruction. A hook, as the name suggests, engages students in learning by triggering their attention and interest. Hooks can be any type of pedagogical approach—a question, a demonstration, a puzzle or video. They are generally short and center on the most interesting aspects of a topic. Here we focus on using Conceptual Change (CC) teacher-led demonstrations as the pedagogical hook approach. Conceptual Change is an instructional method mentioned by a number of authors to stimulate interest among learners. This is where an educator presents an issue or topic that has associated misconceptions. As the teacher explains the truth behind the concept, cognitive conflict occurs and the students' initial perceptions are challenged and ideas start to change. However, the instruction used in association with the demonstrations must provide intelligible, plausible, relevant explanations so that students are convinced by the new ideas. The gap between prior knowledge and new knowledge has the potential to provide a strong stimulus for augmenting interest, engagement, and attention among students. Thus, CC can act as a hook in itself.

  15. Determination of remodeling parameters for a strain-adaptive finite element model of the distal ulna.

    PubMed

    Neuert, Mark A C; Dunning, Cynthia E

    2013-09-01

    Strain energy-based adaptive material models are used to predict bone resorption resulting from stress shielding induced by prosthetic joint implants. Generally, such models are governed by two key parameters: a homeostatic strain-energy state (K) and a threshold deviation from this state required to initiate bone reformation (s). A refinement procedure has been performed to estimate these parameters in the femur and glenoid; this study investigates the specific influences of these parameters on resulting density distributions in the distal ulna. A finite element model of a human ulna was created using micro-computed tomography (µCT) data, initialized to a homogeneous density distribution, and subjected to approximate in vivo loading. Values for K and s were tested, and the resulting steady-state density distribution compared with values derived from µCT images. The sensitivity of these parameters to initial conditions was examined by altering the initial homogeneous density value. The refined model parameters selected were then applied to six additional human ulnae to determine their performance across individuals. Model accuracy using the refined parameters was found to be comparable with that found in previous studies of the glenoid and femur, and gross bone structures, such as the cortical shell and medullary canal, were reproduced. The model was found to be insensitive to initial conditions; however, a fair degree of variation was observed between the six specimens. This work represents an important contribution to the study of changes in load transfer in the distal ulna following the implementation of commercial orthopedic implants.

  16. Accuracy and reproducibility of bending stiffness measurements by mechanical response tissue analysis in artificial human ulnas.

    PubMed

    Arnold, Patricia A; Ellerbrock, Emily R; Bowman, Lyn; Loucks, Anne B

    2014-11-07

    Osteoporosis is characterized by reduced bone strength, but no FDA-approved medical device measures bone strength. Bone strength is strongly associated with bone stiffness, but no FDA-approved medical device measures bone stiffness either. Mechanical Response Tissue Analysis (MRTA) is a non-significant risk, non-invasive, radiation-free, vibration analysis technique for making immediate, direct functional measurements of the bending stiffness of long bones in humans in vivo. MRTA has been used for research purposes for more than 20 years, but little has been published about its accuracy. To begin to investigate its accuracy, we compared MRTA measurements of bending stiffness in 39 artificial human ulna bones to measurements made by Quasistatic Mechanical Testing (QMT). In the process, we also quantified the reproducibility (i.e., precision and repeatability) of both methods. MRTA precision (1.0±1.0%) and repeatability (3.1 ± 3.1%) were not as high as those of QMT (0.2 ± 0.2% and 1.3+1.7%, respectively; both p<10(-4)). The relationship between MRTA and QMT measurements of ulna bending stiffness was indistinguishable from the identity line (p=0.44) and paired measurements by the two methods agreed within a 95% confidence interval of ± 5%. If such accuracy can be achieved on real human ulnas in situ, and if the ulna is representative of the appendicular skeleton, MRTA may prove clinically useful. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Instability of hooks during bacterial flagellar swimming

    NASA Astrophysics Data System (ADS)

    Jabbarzadeh, Mehdi; Fu, Henry C.; Henry Fu Team

    2016-11-01

    In bacteria, a flexible hook transmits torque from the rotary motor at the cell body to the flagellum. Previously, the hook has been modeled as a Kirchhoff rod between the cell body and rotating flagellum. To study effects of the hook's flexibility on the bacteria's swimming speed and trajectory for wide range hook stiffnesses and flagellum configurations, we develop an efficient simplified spring model for the hook by linearizing the Kirchhoff rod. We treat the hydrodynamics of the cell body and helical flagellum using resistance matrices calculated by the method of regularized Stokeslets. We investigate flagellar and swimming dynamics for a range of hook flexibilities and flagellar orientations relative to the cell body and compare the results to models without hook flexibility. We investigate in detail parameters corresponding to E. coli and Vibrio alginolyticus. Generally, the flagellum changes orientation relative to the cell body, undergoing an orbit with the period of the motor rotation. We find that as the hook stiffness decreases, steady-state orbits of the flagellum first become unstable before the hook buckles, which may suggest a new mechanism of flick initiation in run-reverse-flick motility. We also find that for some parameter ranges, there are multiple stable steady state orbits, which may have implications for the tumbling and turning of bacteria.

  18. Ethnic Differences in Bending Stiffness of the Ulna and Tibia

    NASA Technical Reports Server (NTRS)

    Arnaud, S. B.; Liang, M. T. C.; Bassin, S.; Braun, W.; Dutto, D.; Plesums, K.; Huvnh, H. T.; Cooper, D.; Wong, N.

    2004-01-01

    There is considerable information about the variations in bone mass associated with different opportunity to compare a mechanical property of bone in young college women of Caucasian, Hispanic and Asian descent who gave informed consent to participate in an exercise study. The subjects were sedentary, in good health, eumenorrheic, non-smokers and had body mass indices (BMI) less than 30. Measurements acquired were body weight, kg, and height, cm, calcaneal and wrist bone density, g/square cm (PIXI, Lunar GE) and bending stiffness (EI, Nm(exp 2)) in the ulna and tibia. E1 was determined non-invasively with an instrument called the Mechanical Response Tissue Analyzer (MRTA) that delivers a vibratory stimulus to the center of the ulna or tibia and analyzes the response curve based on the equation E1 = k(sub b) L(exp 3)/48 where k, is lateral bending stiffness, L is the length of the bone, E is Young's modulus of elasticity and I, the bending moment of inertia. The error of the test (CV) based on measurements of an aluminum rod with a known E1 was 4.8%, of calcaneal BMD, 0.54%, and of wrist bone density, 3.45%.

  19. 21 CFR 868.5420 - Ether hook.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ether hook. 868.5420 Section 868.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5420 Ether hook. (a) Identification. An ether hook is a device...

  20. A new multipartite plate system for anterior cervical spine surgery; finite element analysis.

    PubMed

    Şimşek, Hakan; Zorlu, Emre; Kaya, Serdar; Baydoğan, Murat; Atabey, Cem; Çolak, Ahmet

    2017-12-19

    There are numerous available plates, almost all of which are compact one-piece plates. During the placement of relatively long plates in the treatment of multi-level cervical pathologies, instrument related complications might appear. In order to overcome this potential problem, a novel 'articulated plate system' is designed. We aimed to delineate finite element analysis and mechanical evaluations. A new plate system consisting of multi partite structure for anterior cervical stabilization was designed. Segmental plates were designed for application onto the ventral surface of the vertebral body. Plates differed from 9 to13 mm in length. There are rods at one end and hooks at the other end. Terminal points consisted of either hooks or rods at one end but the other ends are blind. Finite element and mechanical tests of the construct were performed applying bending, axial loading, and distraction forces. Finite element and mechanical testing results yielded the cut off values for functional failure and breakage of the system. The articulated system proved to be mechanically safe and it lets extension of the system on either side as needed. Ease of application needs further verification via a cadaveric study.

  1. 29 CFR 1915.113 - Shackles and hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... bends or springs the hook. (3) Hooks shall be inspected periodically to see that they have not been bent by overloading. Bent or sprung hooks shall not be used. [47 FR 16986, Apr. 20, 1982, as amended at 51...

  2. 29 CFR 1915.113 - Shackles and hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... bends or springs the hook. (3) Hooks shall be inspected periodically to see that they have not been bent by overloading. Bent or sprung hooks shall not be used. [47 FR 16986, Apr. 20, 1982, as amended at 51...

  3. Comparison of pQCT parameters between ulna and radius in retired elite gymnasts: the skeletal benefits associated with long-term gymnastics are bone- and site-specific.

    PubMed

    Ducher, G; Hill, B L; Angeli, T; Bass, S L; Eser, P

    2009-01-01

    To compare the skeletal benefits associated with gymnastics between ulna and radius. 19 retired artistic gymnasts, aged 18-36 years, were compared to 24 sedentary women. Bone mineral content (BMC), total and cortical bone area (ToA, CoA), trabecular and cortical volumetric density (TrD, CoD) and cortical thickness (CoTh) were measured by pQCT at the 4% and 66% forearm. At the 4% site, BMC and ToA were more than twice greater at the radius than ulna whereas at the 66% site, BMC, ToA, CoA, CoTh and SSIpol were 20 to 51% greater at the ulna than radius in both groups (p<0.0001). At the 4% site, the skeletal benefits in BMC of the retired gymnasts over the non-gymnasts were 1.9 times greater at the radius than ulna (p<0.001), with enlarged bone size at the distal radius only. In contrast, the skeletal benefits at the 66% site were twice greater at the ulna than radius for BMC and CoA (p<0.01). Whereas the skeletal benefits associated with long-term gymnastics were greater at the radius than ulna in the distal forearm, the reverse was found in the proximal forearm, suggesting both bones should be analysed when investigating forearm strength.

  4. "Hooking up" among college students: demographic and psychosocial correlates.

    PubMed

    Owen, Jesse J; Rhoades, Galena K; Stanley, Scott M; Fincham, Frank D

    2010-06-01

    This study investigated 832 college students' experiences with hooking up, a term that refers to a range of physically intimate behavior (e.g., passionate kissing, oral sex, and intercourse) that occurs outside of a committed relationship. Specifically, we examined how five demographic variables (sex, ethnicity, parental income, parental divorce, and religiosity) and six psychosocial factors (e.g., attachment styles, alcohol use, psychological well-being, attitudes about hooking up, and perceptions of the family environment) related to whether individuals had hooked up in the past year. Results showed that similar proportions of men and women had hooked up but students of color were less likely to hook up than Caucasian students. More alcohol use, more favorable attitudes toward hooking up, and higher parental income were associated with a higher likelihood of having hooked up at least once in the past year. Positive, ambivalent, and negative emotional reactions to the hooking up experience(s) were also examined. Women were less likely to report that hooking up was a positive emotional experience than men. Young adults who reported negative and ambivalent emotional reactions to hooking up also reported lower psychological well-being and less favorable attitudes toward hooking up as compared to students who reported a positive hooking up experience. Based on these findings, suggestions for psychoeducational programming are offered. Additionally, directions for future research are provided.

  5. Mechanics of plant fruit hooks

    PubMed Central

    Chen, Qiang; Gorb, Stanislav N.; Gorb, Elena; Pugno, Nicola

    2013-01-01

    Hook-like surface structures, observed in some plant species, play an important role in the process of plant growth and seed dispersal. In this study, we developed an elastic model and further used it to investigate the mechanical behaviour of fruit hooks in four plant species, previously measured in an experimental study. Based on Euler–Bernoulli beam theory, the force–displacement relationship is derived, and its Young's modulus is obtained. The result agrees well with the experimental data. The model aids in understanding the mechanics of hooks, and could be used in the development of new bioinspired Velcro-like materials. PMID:23365190

  6. Ingestion and ejection of hooks: effects on long-term health and mortality of angler-caught yellowfin bream Acanthopagrus australis.

    PubMed

    Broadhurst, Matt K; Butcher, Paul A; Brand, Craig P; Porter, Mark

    2007-02-08

    Ninety juvenile yellowfin bream Acanthopagrus australis were angled from holding tanks, allowed to ingest nickel-plated, carbon-steel J-hooks and released (with their lines cut) into individual experimental tanks during 2 experiments in order to assess their (1) long-term (up to 105 d) health, mortality and rate of hook ejection and (2) short- and medium-term (< 42 d) temporal changes in health during hook ingestion. Equal numbers of control fish were scooped from holding tanks and similarly monitored in experimental tanks. Of 20 hook-ingested fish released during Expt 1, 3 died within 8 d, providing a non-significant mortality of 15%. Between Day 6 and Day 56 post-release, 13 of the surviving individuals ejected their hooks, which were typically oxidized to about 94% of their original weight and often broken into 2 pieces. At Day 105, there were no significant differences between the 20 control and 17 hook-ingested/-ejected fish in terms of their ability to digest and assimilate food (measured as changes in apparent digestibility coefficients), stress (measured as concentrations of plasma cortisol and glucose) or of morphological parameters that included weight (Wt) and maximum height (MH), maximum width (MW) and maximum girth (MG). During Expt 2, 3 individuals that still contained ingested hooks and 3 controls were sampled on each of 9 occasions between Day 3 and Day 42 post-release. All fish were sampled for blood cortisol and glucose and were then euthanized before being weighed and measured for total length (TL), MH, MW and MG. Hook-ingested individuals were also X-rayed to determine the position and orientation of hooks. There were no significant differences in plasma glucose between hook-ingested and control fish. Irrespective of the treatment of fish, concentrations of cortisol were elevated on some sampling occasions, indicating variable, acute stress. The MH and MG of fish were not significantly different between groups. Significant differences were

  7. Robert Hooke, 1635-1703.

    PubMed

    Rowbury, Robin

    2012-01-01

    Robert Hooke was a polymath whose expertise during the 17th century spanned many different scientific areas. As a schoolboy on the Isle of Wight he was obsessed with the possibility of human flight and later became equally absorbed in cosmology and planetary motion. His skills as an artist were put to good use both as an architect following the Great Fire of London and before that in Micrographia. Although that book is best known for demonstrating the power of Hooke's microscope, Micrographia describes distant planetary bodies, the wave theory of light, the organic origin of fossils, and various other philosophical and scientific interests of its author The following thumbnail sketches of Hooke reveal him to be a man of enormous energy and imagination whose ideas were often pirated or under-rated.

  8. In vivo study of magnesium plate and screw degradation and bone fracture healing.

    PubMed

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Myers, Nicole; Costello, Bernard J; Chou, Da-Tren; Pal, Siladitya; Maiti, Spandan; Kumta, Prashant N; Sfeir, Charles

    2015-05-01

    Each year, millions of Americans suffer bone fractures, often requiring internal fixation. Current devices, like plates and screws, are made with permanent metals or resorbable polymers. Permanent metals provide strength and biocompatibility, but cause long-term complications and may require removal. Resorbable polymers reduce long-term complications, but are unsuitable for many load-bearing applications. To mitigate complications, degradable magnesium (Mg) alloys are being developed for craniofacial and orthopedic applications. Their combination of strength and degradation make them ideal for bone fixation. Previously, we conducted a pilot study comparing Mg and titanium devices with a rabbit ulna fracture model. We observed Mg device degradation, with uninhibited healing. Interestingly, we observed bone formation around degrading Mg, but not titanium, devices. These results highlighted the potential for these fixation devices. To better assess their efficacy, we conducted a more thorough study assessing 99.9% Mg devices in a similar rabbit ulna fracture model. Device degradation, fracture healing, and bone formation were evaluated using microcomputed tomography, histology and biomechanical tests. We observed device degradation throughout, and calculated a corrosion rate of 0.40±0.04mm/year after 8 weeks. In addition, we observed fracture healing by 8 weeks, and maturation after 16 weeks. In accordance with our pilot study, we observed bone formation surrounding Mg devices, with complete overgrowth by 16 weeks. Bend tests revealed no difference in flexural load of healed ulnae with Mg devices compared to intact ulnae. These data suggest that Mg devices provide stabilization to facilitate healing, while degrading and stimulating new bone formation. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. Synthetic Minor NSR Permit: Van Hook Crude Terminal, LLC - Van Hook Crude Terminal/Rail Loading Facility

    EPA Pesticide Factsheets

    This page contains the current effective synthetic minor NSR permit for the Van Hook Crude Terminal, LLC, Van Hook Crude Terminal/Rail Loading Facility, located on the Fort Berthold Indian Reservation in Mountrail County, ND.

  10. Designing physics video hooks for science students

    NASA Astrophysics Data System (ADS)

    McHugh, M.; McCauley, V.

    2016-01-01

    This paper offers an insight into the design structure of physics video hooks that were developed by the Science Education Resource design team in the school of education (SOE) in National University of Ireland, Galway (NUI Galway). A hook, is an instructional technique used to stimulate student attention (Hunter 1994, Lemov 2010), interest (Jewett 2013) and engagement (McCrory 2011, Riendeau 2013). The physics video hooks followed a design framework that is illustrated below by breaking down the centre of gravity (COG) hook. Various design principles and elements embedded within the COG hook are presented with examples and the time they occur within the video. The intention of this article is that the design can be replicated and modified to aid teachers and designers in the development of a multitude of classroom based multimedia resources.

  11. Performance of barbed and barbless hooks in a marine recreational fishery

    USGS Publications Warehouse

    Schaeffer, Jeffrey S.; Hoffman, Elizabeth M.

    2002-01-01

    We used an angling study to examine catch per unit effort (CPUE), bait loss, and total landings by anglers fishing with natural bait on barbed and barbless hooks in a nearshore marine sport fishery located in the Gulf of Mexico near St. Petersburg, Florida. Anglers fished half the day with a barbed hook and half the day with a barbless hook. We also recorded anatomical hook placement, severity of injury or bleeding, and hook extraction times for each landed fish. Bait loss, CPUE, and mean length of catch did not differ between gears, but anglers landed 22% more fish with barbed hooks. Loss of hooked fish was significantly higher with barbless hooks, and efficiency appeared to vary among species. Mean unhooking times were significantly shorter with barbless hooks. Anatomical hook placement did not differ between gears and most fish were hooked in the jaws. Bleeding did not differ between gears because bleeding was influenced strongly by hook placement, but barbless hooks reduced unhooking injuries. In this fishery, barbless hooks probably did not reduce hooking mortality and conferred only slight benefits at the expense of reduced catches.

  12. Clathrin-Mediated Auxin Efflux and Maxima Regulate Hypocotyl Hook Formation and Light-Stimulated Hook Opening in Arabidopsis.

    PubMed

    Yu, Qinqin; Zhang, Ying; Wang, Juan; Yan, Xu; Wang, Chao; Xu, Jian; Pan, Jianwei

    2016-01-04

    The establishment of auxin maxima by PIN-FORMED 3 (PIN3)- and AUXIN RESISTANT 1/LIKE AUX1 (LAX) 3 (AUX1/LAX3)-mediated auxin transport is essential for hook formation in Arabidopsis hypocotyls. Until now, however, the underlying regulatory mechanism has remained poorly understood. Here, we show that loss of function of clathrin light chain CLC2 and CLC3 genes enhanced auxin maxima and thereby hook curvature, alleviated the inhibitory effect of auxin overproduction on auxin maxima and hook curvature, and delayed blue light-stimulated auxin maxima reduction and hook opening. Moreover, pharmacological experiments revealed that auxin maxima formation and hook curvature in clc2 clc3 were sensitive to auxin efflux inhibitors 1-naphthylphthalamic acid and 2,3,5-triiodobenzoic acid but not to the auxin influx inhibitor 1-naphthoxyacetic acid. Live-cell imaging analysis further uncovered that loss of CLC2 and CLC3 function impaired PIN3 endocytosis and promoted its lateralization in the cortical cells but did not affect AUX1 localization. Taken together, these results suggest that clathrin regulates auxin maxima and thereby hook formation through modulating PIN3 localization and auxin efflux, providing a novel mechanism that integrates developmental signals and environmental cues to regulate plant skotomorphogenesis and photomorphogenesis. Copyright © 2016 The Author. Published by Elsevier Inc. All rights reserved.

  13. Use of locking compression plates in ulnar fractures of 18 horses.

    PubMed

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  14. Histopathologic and Radiographic evaluation of the electroacupuncture effects on ulna fracture healing in dogs.

    PubMed

    Naddaf, H; Baniadam, A; Esmaeilzadeh, S; Ghadiri, A R; Pourmehdi, M; Falah, H; Hosseini, O; Farmani, F; Sabiza, S

    2014-01-01

    Acupuncture can affect bone healing by stimulation of sensory nerves and releasing of local and systemic neuropeptides. The purpose of this experimental study was to evaluate the effects of electroacupuncture on ulna fracture healing in dogs. In this study, 12 healthy dogs were randomly divided in to four equal groups, where group 1 was kept as control group and evaluated for 45 days, group 2: treatment group and evaluated for 45 days, group3: control group of 90 days and group 4: treatment group of 90 days. After induction of anesthesia, the ulna was cut with Gigli wire saw in each groups, 10 days after operation, the treatment (acupuncture) group was treated with 10 minutes electroacupuncture stimulations on the acupoints Kid1, Kid3, Kid6 and Kid7, for 10 days. Histopathologic samples of all dogs were harvested from bone osteotomized site in 45 and 90 days after surgery. Indices like, count of inflammatory cells, cartilaginous tissue, fibrotic tissue and deposition of collagen were evaluated on samples and classified with 0, 1, 2, and 3 degrees. Also, radiographic evaluation of the patients was applied using radiographic scoring system on days: 7, 15, 30, 45, 60 and 90 after surgery. This study revealed that, acupuncture had no effect on bone healing (p>0.05). Cause of non-significant difference changes between the control and treatment groups, and lack of complete healing in both groups may be due to lack of ulna bone fixation. Alternatively, selection of other acupoints in acupuncture could have a better healing role.

  15. The Topic Is Sandy Hook: A Program for Gifted and Talented Students at Sandy Hook.

    ERIC Educational Resources Information Center

    Grant, David

    "The Topic Is Sandy Hook" is an experiential 10-week program designed to provide special opportunities and educational experiences for 6th to 10th grade gifted and talented students. Sandy Hook, a natural resource in Monmouth County, New Jersey, is unique in its physical and historical features and provides an exceptionally rich environment in…

  16. [Stabilization of the injured acromioclavicular joint using a new type of fixation plate].

    PubMed

    Sánta, S; Záborszky, Z; Varga, Z

    1992-01-01

    The opinions in the question of transitory fixation of the joint during the treatment of the acromioclavicular articulation are rather different. The complications of the widely used methods--break of the implant, its tear from the bone, the wandering and the disturbances of wound healing--are well known. To decrease the number of complications authors have developed a new type of hooked plate. The plate is fitted to the anterior surface of the acromial end of the clavicle and its hook is fixed from below in the bore hole of the acromion. To choose the optimal place of the bore hole a drill guide was prepared. The operative method is described and the advantages of the method are summarized. The "Debrecen-plate" was used during 2 years in 39 injuries. 35 patients were controlled 6-24 months after the operation. Based on the results of the treatment a wider use of the method is suggested.

  17. Two-wave propagation in in vitro swine distal ulna

    NASA Astrophysics Data System (ADS)

    Mano, Isao; Horii, Kaoru; Matsukawa, Mami; Otani, Takahiko

    2015-07-01

    Ultrasonic transmitted waves were obtained in an in vitro swine distal ulna specimen, which mimics a human distal radius, that consists of interconnected cortical bone and cancellous bone. The transmitted waveforms appeared similar to the fast waves, slow waves, and overlapping fast and slow waves measured in the specimen after removing the surface cortical bone (only cancellous bone). In addition, the circumferential waves in the cortical bone and water did not affect the fast and slow waves. This suggests that the fast-and-slow-wave phenomenon can be observed in an in vivo human distal radius.

  18. String Technique for Anterior Orbital Fish Hook Removal.

    PubMed

    Starr, Matthew R; Choi, Michael B; Mahr, Michael A; Mettu, Pradeep; Patterson, David F

    2018-06-13

    Removing fish hooks is a common procedure performed by many emergency department providers. There are several techniques that are commonly employed to aid in successful removal. However, when a fish hook becomes embedded within the orbit, there are limited options as to avoid damaging vital surrounding structures. The authors report the removal of a fish hook within the anterior orbit using the string technique in a 25-year-old patient. The procedure was performed under general anesthesia with the aid of size 5 polyglactin suture wrapped around the hook. The procedure itself took less than 10 seconds and was successful in swiftly and safely removing the hook without damaging surrounding orbital structures. The patient recovered well without any permanent sequelae.

  19. Microanatomy of the cochlear hook

    NASA Astrophysics Data System (ADS)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  20. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    PubMed

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  1. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  2. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  3. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  4. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  5. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  6. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  7. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  8. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  9. 30 CFR 56.19075 - Use of open hooks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Use of open hooks. 56.19075 Section 56.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 56.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  10. 30 CFR 57.19075 - Use of open hooks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Use of open hooks. 57.19075 Section 57.19075 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Hoisting Procedures § 57.19075 Use of open hooks. Open hooks shall not be used to hoist buckets or other...

  11. Drawings of fossils by Robert Hooke and Richard Waller

    PubMed Central

    Kusukawa, Sachiko

    2013-01-01

    The drawings of fossils by Robert Hooke and Richard Waller that were the basis of the engravings in Hooke's Posthumous works (1705) are published here for the first time. The drawings show that both Hooke and Waller were proficient draftsmen with a keen eye for the details of petrified objects. These drawings provided Hooke with a polemic edge in making the case for the organic origins of ‘figured stones’.

  12. Hook1 inhibits malignancy and epithelial-mesenchymal transition in hepatocellular carcinoma.

    PubMed

    Sun, Xu; Zhang, Qi; Chen, Wei; Hu, Qida; Lou, Yu; Fu, Qi-Han; Zhang, Jing-Ying; Chen, Yi-Wen; Ye, Long-Yun; Wang, Yi; Xie, Shang-Zhi; Hu, Li-Qiang; Liang, Ting-Bo; Bai, Xue-Li

    2017-07-01

    Hook1 is a member of the hook family of coiled-coil proteins, which is recently found to be associated with malignant tumors. However, its biological function in hepatocellular carcinoma is yet unknown. Here, we evaluated the Hook1 levels in human hepatocellular carcinoma samples and matched peritumoral tissues by real-time polymerase chain reaction. Small interfering RNA knockdown and a transforming growth factor-β-induced epithelial-mesenchymal transition model were employed to investigate the biological effects of Hook1 in hepatocellular carcinoma. Our results indicated that Hook1 levels were significantly lower in hepatocellular carcinoma tissues than in the peritumoral tissues. In addition, Hook1 expression was significantly associated with hepatocellular carcinoma malignancy. Hook1 was downregulated after transforming growth factor-β-induced epithelial-mesenchymal transition. Moreover, Hook1 knockdown promoted epithelial-mesenchymal transition and attenuated the sensitivity of hepatocellular carcinoma cells to doxorubicin. In summary, our results indicate that downregulation of Hook1 plays a pivotal role in hepatocellular carcinoma progression via epithelial-mesenchymal transition. Hook1 may be used as a novel marker and therapeutic molecular target in hepatocellular carcinoma.

  13. BOOK REVIEW: Robert Hooke and the Royal Society

    NASA Astrophysics Data System (ADS)

    Brown, Neil

    2000-01-01

    Many physics students only come across Hooke when they learn his law of stretching springs, which is a pity because it is just one of his contributions to progress in science, and a minor one at that. His, Micrographia, the first great book of microscopical observations, arouses admiration to this day. He was also active in horology, astronomy, geology and surveying, and he took part in biological experiments, transfusing blood between animals. Much of his work was done while he was curator of experiments for the Royal Society, in which he was involved almost from its foundation. This was by no means a full-time occupation, however. After the Great Fire of London, Hooke was appointed one of the three surveyors for the rebuilding of the city. One of the others was Christopher Wren, a lifelong friend. In this role Hooke was responsible for the design of several buildings, including the Monument. Nichols writes about all these activities, as well as Hooke's childhood, his education at Westminster School, the University of Oxford when Hooke was an undergraduate, and the founding of the Royal Society. The book draws on research for a master's degree. Turning a dissertation into a popular book is risky. The author has avoided the pitfall of making it too academic, but the result is not satisfying. Nichols seems overawed by Hooke and his work, frequently seeming to credit Hooke with a far-reaching influence that he did not necessarily have. There may be a case for lauding Hooke as the father of English microscopy, the father of English meteorology, and the founder of English geology and earth sciences, but it needs to be made much more critically, even in a popular work. Hooke was full of good ideas, but he rarely continued long enough to put them into practice. There is no doubt that Hooke proposed using a balance wheel and spring to improve the timekeeping of a watch, for example, but he did not have a watch made to his design until after Christiaan Huygens had

  14. Evolutionary anatomy of the Neandertal ulna and radius in the light of the new El Sidrón sample.

    PubMed

    Pérez-Criado, Laura; Rosas, Antonio

    2017-05-01

    This paper aims to improve our understanding of the phylogenetic trait polarity related to hominin forearm evolution, in particular those traits traditionally defined as "Neandertal features." To this aim, twelve adult and adolescent fragmented forelimb elements (including ulnae and radii) of Homo neanderthalensis recovered from the site of El Sidrón (Asturias, Spain) were examined comparatively using three-dimensional geometric and traditional morphometrics. Mean centroid size and shape comparisons, principal components analysis, and phylogenetic signal analysis were undertaken. Our investigations revealed that the proximal region of the ulna discriminated best between Neandertals and modern humans, with fewer taxonomically-informative features in the distal ulna and radius. Compared to modern humans, the divergent features in the Neandertal ulna are an increase in olecranon breadth (a derived trait), lower coronoid length (primitive), and anterior orientation of the trochlear notch (primitive). In the Neandertal radius, we observe a larger neck length (primitive), medial orientation of the radial tubercle (secondarily primitive), and a curved diaphysis (secondarily primitive). Anatomically, we identified three units of evolutionary change: 1) the olecranon and its fossa, 2) the coronoid-radius neck complex, and 3) the tubercle and radial diaphysis. Based on our data, forearm evolution followed a mosaic pattern in which some features were inherited from a pre-Homo ancestor, others originated in some post-ergaster and pre-antecessor populations, and other characters emerged in the specific Homo sapiens and H. neanderthalensis lineages, sometimes appearing as secondarily primitive. Future investigations might consider the diverse phylogenetic origin of apomorphies while at the same time seeking to elucidate their functional meaning. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Fish-hook injuries: a risk for fishermen

    PubMed Central

    2010-01-01

    Fishing is one of the best known and practiced human activities. However, you should remember that, when casting the hook from the riverbank or grasping it to add bait, fishermen run a real risk of injury if the hook punctures the skin. Briefly we describe a case where a young, 32-year-old fisherman who was reeling the hook back to shore when it hit him in the face and embedded itself in his upper eyelid. Upon examination, the eye was found to be unharmed and the hook was removed through a small incision and the aid of a local anesthetic. In the light of this case report, we think it a good idea to advise our friends and patients who we know to be fishermen to wear some form of eye protection as a precaution. PMID:21156039

  16. Robert Hooke's model of memory.

    PubMed

    Hintzman, Douglas L

    2003-03-01

    In 1682 the scientist and inventor Robert Hooke read a lecture to the Royal Society of London, in which he described a mechanistic model of human memory. Yet few psychologists today seem to have heard of Hooke's memory model. The lecture addressed questions of encoding, memory capacity, repetition, retrieval, and forgetting--some of these in a surprisingly modern way. Hooke's model shares several characteristics with the theory of Richard Semon, which came more than 200 years later, but it is more complete. Among the model's interesting properties are that (1) it allows for attention and other top-down influences on encoding; (2) it uses resonance to implement parallel, cue-dependent retrieval; (3) it explains memory for recency; (4) it offers a single-system account of repetition priming; and (5) the power law of forgetting can be derived from the model's assumptions in a straightforward way.

  17. Hooking Up and Identity Development of Female College Students

    ERIC Educational Resources Information Center

    Kooyman, Leslie; Pierce, Gloria; Zavadil, Amy

    2011-01-01

    Hooking up generally involves casual sex with noncommittal partners. Hooking up is prevalent on college campuses today and can negatively affect the identity development of female students. The authors examined this phenomenon with a feminist developmental perspective, evaluating hooking up in the context of sexual risk taking with physical and…

  18. Estimating freshwater turtle mortality rates and population declines following hook ingestion.

    PubMed

    Steen, David A; Robinson, Orin J

    2017-12-01

    Freshwater turtle populations are susceptible to declines following small increases in the mortality of adults, making it essential to identify and understand potential threats. Freshwater turtles ingest fish hooks associated with recreational angling, and this is likely a problem because hook ingestion is a source of additive mortality for sea turtles. We used a Bayesian-modeling framework, observed rates of hook ingestion by freshwater turtles, and mortality of sea turtles from hook ingestion to examine the probability that a freshwater turtle in a given population ingests a hook and subsequently dies from it. We used the results of these analyses and previously published life-history data to simulate the effects of hook ingestion on population growth for 3 species of freshwater turtle. In our simulation, the probability that an individual turtle ingests a hook and dies as a result was 1.2-11%. Our simulation results suggest that this rate of mortality from hook ingestion is sufficient to cause population declines. We believe we have identified fish-hook ingestion as a serious yet generally overlooked threat to the viability of freshwater turtle populations. © 2017 Society for Conservation Biology.

  19. Cut-it-out technique for ocular fish-hook injury.

    PubMed

    Ahmad, Syed Shoeb; Seng, Chiang Wai; Ghani, Shuaibah Abdul; Lee, Jane F

    2013-10-01

    An 11-year-old boy was involved in an injury with a fish-hook to his eye. The hook had impaled itself to the cornea and deeper structures. There was associated corneal edema and hyphema, making visualization difficult. In this case, we performed the unusual "cut-it-out" technique to remove the hook from the eye.

  20. In vitro Antioxidant of a Water-Soluble Polysaccharide from Dendrobium fimhriatum Hook.var.oculatum Hook

    PubMed Central

    Luo, Aoxue; Fan, Yijun

    2011-01-01

    A water-soluble crude polysaccharide (DFHP) obtained from the aqueous extracts of the stem of Dendrobium fimhriatum Hook.var.oculatum Hook through hot water extraction followed by ethanol precipitation, was found to have an average molecular weight (Mw) of about 209.3 kDa. Monosaccharide analysis revealed that DFHP was composed of mannose, glucose and galactose in a content ratio of 37.52%; 43.16%; 19.32%. The investigation of antioxidant activity in vitro showed that DFHP is a potential antioxidant. PMID:21747725

  1. Can hook-bending be let off the hook? Bending/unbending of pliant tools by cockatoos.

    PubMed

    Laumer, I B; Bugnyar, T; Reber, S A; Auersperg, A M I

    2017-09-13

    The spontaneous crafting of hook-tools from bendable material to lift a basket out of a vertical tube in corvids has widely been used as one of the prime examples of animal tool innovation. However, it was recently suggested that the animals' solution was hardly innovative but strongly influenced by predispositions from habitual tool use and nest building. We tested Goffin's cockatoo, which is neither a specialized tool user nor a nest builder, on a similar task set-up. Three birds individually learned to bend hook tools from straight wire to retrieve food from vertical tubes and four subjects unbent wire to retrieve food from horizontal tubes. Pre-experience with ready-made hooks had some effect but was not necessary for success. Our results indicate that the ability to represent and manufacture tools according to a current need does not require genetically hardwired behavioural routines, but can indeed arise innovatively from domain general cognitive processing. © 2017 The Authors.

  2. Feasibility and fidelity of practising surgical fixation on a virtual ulna bone

    PubMed Central

    LeBlanc, Justin; Hutchison, Carol; Hu, Yaoping; Donnon, Tyrone

    2013-01-01

    Background Surgical simulators provide a safe environment to learn and practise psychomotor skills. A goal for these simulators is to achieve high levels of fidelity. The purpose of this study was to develop a reliable surgical simulator fidelity questionnaire and to assess whether a newly developed virtual haptic simulator for fixation of an ulna has comparable levels of fidelity as Sawbones. Methods Simulator fidelity questionnaires were developed. We performed a stratified randomized study with surgical trainees. They performed fixation of the ulna using a virtual simulator and Sawbones. They completed the fidelity questionnaires after each procedure. Results Twenty-two trainees participated in the study. The reliability of the fidelity questionnaire for each separate domain (environment, equipment, psychological) was Cronbach α greater than 0.70, except for virtual environment. The Sawbones had significantly higher levels of fidelity than the virtual simulator (p < 0.001) with a large effect size difference (Cohen d < 1.3). Conclusion The newly developed fidelity questionnaire is a reliable tool that can potentially be used to determine the fidelity of other surgical simulators. Increasing the fidelity of this virtual simulator is required before its use as a training tool for surgical fixation. The virtual simulator brings with it the added benefits of repeated, independent safe use with immediate, objective feedback and the potential to alter the complexity of the skill. PMID:23883510

  3. Ethylene Is Not Responsible for Phytochrome-Mediated Apical Hook Exaggeration in Tomato

    PubMed Central

    Takahashi-Asami, Miki; Shichijo, Chizuko; Tsurumi, Seiji; Hashimoto, Tohru

    2016-01-01

    The apical hook of tomato seedlings is exaggerated by phytochrome actions, while in other species such as bean, pea and Arabidopsis, the hook is exaggerated by ethylene and opens by phytochrome actions. The present study was aimed to clarify mainly whether ethylene is responsible for the phytochrome-mediated hook exaggeration of tomato seedlings. Dark-grown 5-day-old seedlings were subjected to various ways of ethylene application in the dark as well as under the actions of red (R) or far-red light (FR). The ethylene emitted by seedlings was also quantified relative to hook exaggeration. The results show: Ambient ethylene, up-to about 1.0 μL L-1, suppressed (opened) the hooks formed in the dark as well as the ones exaggerated by R or FR, while at 3.0–10 μL L-1 it enhanced (closed) the hook only slightly as compared with the most-suppressed level at about 1.0 μL L-1. Treatment with 1-aminocyclopropane-1-carboxylic acid (ACC), the immediate precursor of ethylene biosynthesis, did not enhance the hook, only mimicking the suppressive effects of ambient ethylene. The biosynthesis inhibitor, CoCl2 or aminoethoxyvinylglycine, enhanced hook curvature, and the enhancement was canceled by supplement of ethylene below 1.0 μL L-1. Auxin transport inhibitor, N-1-naphthylphthalamic acid, by contrast, suppressed curvature markedly without altering ethylene emission. The effects of the above-stated treatments did not differentiate qualitatively among the R-, FR-irradiated seedlings and dark control so as to explain phytochrome-mediated hook exaggeration. In addition, ethylene emission by seedlings was affected neither by R nor FR at such fluences as to cause hook exaggeration. In conclusion, (1) ethylene suppresses not only the light-exaggerated hook, but also the dark-formed one; (2) ethylene emission is not affected by R or FR, and also not correlated with the hook exaggerations; thus ethylene is not responsible for the hook exaggeration in tomato; and (3) auxin is

  4. [Roof folding and rotary pushing for the treatment of back to back fractures of distal radius and ulna in children].

    PubMed

    Xu, Ping; Dong, Xiao-jun; Lu, Zhou-tong; Wang, Gongjun; Zhang, Han-qing; Chen, Xuan-ning; Li, Dong

    2015-09-01

    To evaluate the technique and the clinical effect of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back". From January 2012 to February 2014,38 children with distal radius and ulna fracture of "back to back" were treated by using the technique of folding roof and rotary pushing to reset and splint fixation including 23 males and 15 females with an average age of 9.5 years old ranging from 6 to 14 years old. Injury time was from 45 min to 3 days (averaged 1.3 days). All cases was unilateral closed fracture without symptoms of nerve injury occurred. The wrist joint anteroposterior and lateral radiographs showed double fracture of radius and ulna, and the broken end of radius was typical "back to back" displacement. The quality of reduction was assessed according to Dienst recommendation on the combination of Aro measurement, and the therapeutic effect was evaluated using standard of Anderson function. All patients were followed up from 3 to 13 months with an average of 6 months. There were no iatrogenic nerve injury. Thirty cases were treated successfully for the first time, 8 cases were again reset successfully; 28 cases were anatomical reduction, 7 cases were near anatomic reduction, 3 cases were functional reduction. At the second day 7 cases with hand and finger swelling appeared in multiple reset patients. Quality results of reduction were excellent in 33 cases, good in 5 cases. According to the standard of Anderson function evaluation, 35 cases were excellent, 3 cases were good. All fractures were healed with of deformity of wrist. Using the technique of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back" is very successful, the patient's limb function recovered well, the whole operation process is simple.

  5. A Pedagogy of Sight: Microscopic Vision in Robert Hooke's "Micrographia"

    ERIC Educational Resources Information Center

    Jack, Jordynn

    2009-01-01

    Robert Hooke's "Micrographia" (1665) holds an important place in the history of scientific visual rhetoric. Hooke's accomplishment lies not only in a stunning array of engravings, but also in a "pedagogy of sight"--a rhetorical framework that instructs readers how to view images in accordance with an ideological or epistemic program. Hooke not…

  6. Sidney Hook's Pragmatic Anti-Communism: Commitment to Democracy as Method

    ERIC Educational Resources Information Center

    Ferriter, Courtney

    2017-01-01

    In recent years, opposition to Communism has emerged as Sidney Hook's central philosophical legacy in the eyes of scholars and historians, who tend to ignore all of Hook's pre-Cold War philosophical contributions. Furthermore, critics who treat Hook's anti-Communism often accuse him of abandoning pragmatism for dogmatism in his later career. In…

  7. Diagnosis and management of hook of hamate fractures.

    PubMed

    Kadar, Assaf; Bishop, Allen T; Suchyta, Marissa A; Moran, Steven L

    2018-06-01

    The purpose of this study was to evaluate the time to diagnosis and management of hook of hamate fractures in an era of advanced imaging. We performed a retrospective study of 51 patients treated for hook of hamate fractures. Patients were sent a quickDASH questionnaire regarding the outcomes of their treatment. Hook of hamate fractures were diagnosed with advanced imaging at a median of 27 days. Clinical findings of hook of hamate tenderness had better sensitivity than carpal tunnel-view radiographs. Nonunion occurred in 24% of patients with non-operative treatment and did not occur in the operative group. Both treatment groups achieved good clinical results, with a grip strength of 80% compared with the non-injured hand and a median quickDASH score of 2. Advanced imaging improved the time to diagnosis and treatment compared to historical case series. Nonunion is common in patients treated non-operatively. IV.

  8. 76 FR 11961 - Safety Zone, Dredging Operations; Delaware River, Marcus Hook, PA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ...-AA00 Safety Zone, Dredging Operations; Delaware River, Marcus Hook, PA AGENCY: Coast Guard, DHS. ACTION... Delaware River while the Dredge Pullen conducts dredging operations at the Sunoco Marcus Hook docks in the vicinity of the Marcus Hook Range near Marcus Hook, PA. This action is necessary to maintain the 42 ft...

  9. Education as a Practice of Freedom: Reflections on bell hooks

    ERIC Educational Resources Information Center

    Specia, Akello; Osman, Ahmed A.

    2015-01-01

    This paper critically analyses the conceptions of bell hooks on education. It focuses on the relevance of hook's ideas to the classroom. It is a theoretical paper based on secondary data that seeks to contribute to the growing body of knowledge in education. The paper is a reflection of hook's reaction to education as a practice of freedom, the…

  10. Newton–Hooke-type symmetry of anisotropic oscillators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, P.M., E-mail: zhpm@impcas.ac.cn; Horvathy, P.A., E-mail: horvathy@lmpt.univ-tours.fr; Laboratoire de Mathématiques et de Physique Théorique, Université de Tours

    2013-06-15

    Rotation-less Newton–Hooke-type symmetry, found recently in the Hill problem, and instrumental for explaining the center-of-mass decomposition, is generalized to an arbitrary anisotropic oscillator in the plane. Conversely, the latter system is shown, by the orbit method, to be the most general one with such a symmetry. Full Newton–Hooke symmetry is recovered in the isotropic case. Star escape from a galaxy is studied as an application. -- Highlights: ► Rotation-less Newton–Hooke (NH) symmetry is generalized to an arbitrary anisotropic oscillator. ► The orbit method is used to find the most general case for rotation-less NH symmetry. ► The NH symmetry ismore » decomposed into Heisenberg algebras based on chiral decomposition.« less

  11. Hook2 is involved in the morphogenesis of the primary cilium

    PubMed Central

    Baron Gaillard, Carole L.; Pallesi-Pocachard, Emilie; Massey-Harroche, Dominique; Richard, Fabrice; Arsanto, Jean-Pierre; Chauvin, Jean-Paul; Lecine, Patrick; Krämer, Helmut; Borg, Jean-Paul; Le Bivic, André

    2011-01-01

    Primary cilia originate from the centrosome and play essential roles in several cellular, developmental, and pathological processes, but the underlying mechanisms of ciliogenesis are not fully understood. Given the involvement of the adaptor protein Hook2 in centrosomal homeostasis and protein transport to pericentrosomal aggresomes, we explored its role in ciliogenesis. We found that in human retinal epithelial cells, Hook2 localizes at the Golgi apparatus and centrosome/basal body, a strategic partitioning for ciliogenesis. Of importance, Hook2 depletion disrupts ciliogenesis at a stage before the formation of the ciliary vesicle at the distal tip of the mother centriole. Using two hybrid and immunoprecipitation assays and a small interfering RNA strategy, we found that Hook2 interacts with and stabilizes pericentriolar material protein 1 (PCM1), which was reported to be essential for the recruitment of Rab8a, a GTPase that is believed to be crucial for membrane transport to the primary cilium. Of interest, GFP::Rab8a coimmunoprecipitates with endogenous Hook2 and PCM1. Finally, GFP::Rab8a can overcome Hook2 depletion, demonstrating a functional interaction between Hook2 and these two important regulators of ciliogenesis. The data indicate that Hook2 interacts with PCM1 in a complex that also contains Rab8a and regulates a limiting step required for further initiation of ciliogenesis after centriole maturation. PMID:21998199

  12. Hooking-Up, Religiosity, and Sexting Among College Students.

    PubMed

    Hall, Michael; Williams, Ronald D; Ford, M Allison; Cromeans, Erin Murphy; Bergman, Randall J

    2016-07-28

    The purpose of this study was to evaluate the mediation effect of sexting, and taking sexually suggestive photos on religiosity and hooking-up with three separate sexual outcomes. A web-based survey examined the relationship between religiosity and the three hooking-up outcomes among students reporting sexting or taking a sexually suggestive photo in the last 30 days (n = 231). Sexting, as well as taking sexually suggestive photos mediated the relationship between religiosity and hooking-up among females. Sexting may be initiated by females as a way to engage in a nonphysical sexual interaction, which ultimately predisposes them to a physical sexual outcome.

  13. Congenital band syndrome with pseudarthrosis of the radius and ulna and impending vascular compromise: a case report.

    PubMed

    Ho, Christine A; Richards, B Stephens; Ezaki, Marybeth

    2014-09-01

    Although amniotic band syndrome is relatively rare, reports of pseudarthrosis in conjunction with amniotic band syndrome are even rarer, as are reports of impending vascular compromise in the neonatal period. Careful serial examinations and timely surgical intervention can successfully avoid the catastrophic event of limb loss. We report on a case of upper extremity amniotic band syndrome with pseudarthrosis of the radius and ulna that was complicated by vascular compromise in a neonate. Chart and radiographic data for this single case were reviewed and reported retrospectively. A 1-day-old neonate born at 28 3/7 weeks of gestational age was transferred to our institution for increased swelling to the forearm distal to a congenital band associated with an underlying radius and ulna pseudarthrosis. Although the forearm and hand were soft and viable initially, severe edema and swelling occurred after fluid resuscitation, and on the fourth day of life, the patient underwent simple band releases at bedside with 2 longitudinal incisions over the radius and ulna. Circulation was restored, and the pseudarthrosis healed with no further surgical intervention. Successful delayed reconstruction of the band with Z-plasties was performed when the baby was 7 months of age. In this case, a relatively simple, straightforward procedure that is familiar to most pediatric orthopaedists salvaged a compromised neonatal limb with amniotic band syndrome and allowed healing of a pseudarthrosis, allowing more complex reconstruction to be performed in a delayed, elective manner. Careful observation is necessary in the neonatal period of the baby with a severe band; a viable, well-perfused, compressible extremity may still be at risk.

  14. 46 CFR 173.007 - Location of the hook load.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PERTAINING TO VESSEL USE Lifting § 173.007 Location of the hook load. When doing the calculations required in this subpart, the hook load must be considered to be located at the head of the crane. ...

  15. Interactions of light and ethylene in hypocotyl hook maintenance in Arabidopsis thaliana seedlings

    NASA Technical Reports Server (NTRS)

    Knee, E. M.; Hangarter, R. P.; Knee, M.

    2000-01-01

    Etiolated seedlings frequently display a hypocotyl or epicotyl hook which opens on exposure to light. Etylene has been shown to be necessary for maintenance of the hook in a number of plants in darkness. We investigated the interaction of ethylene and light in the regulation of hypocotyl hook opening in Arabidopsis thaliana. We found that hooks of Arabidopsis open in response to continuous red, far-red or blue light in the presence of up to 100 microliters l-1 ethylene. Thus a change in sensitivity to ethylene is likely to be responsible for hook opening in Arabidopsis, rather than a decrease in ethylene production in hook tissues. We used photomorphogenic mutants of Arabidopsis to demonstrate the involvement of both blue light and phytochrome photosensory systems in light-induced hook opening in the presence of ethylene. In addition we used ethylene mutants and inhibitors of ethylene action to investigate the role of ethylene in hook maintenance in seedlings grown in light and darkness.

  16. Engineering Evaluation of International Low Impact Docking System Latch Hooks

    NASA Technical Reports Server (NTRS)

    Martinez, J.; Patin, R.; Figert, J.

    2013-01-01

    The international Low Impact Docking System (iLIDS) provides a structural arrangement that allows for visiting vehicles to dock with the International Space Station (ISS) (Fig 1). The iLIDS docking units are mechanically joined together by a series of active and passive latch hooks. In order to preserve docking capability at the existing Russian docking interfaces, the iLIDS latch hooks are required to conform to the existing Russian design. The latch hooks are classified as being fail-safe. Since the latch hooks are fail-safe, the hooks are not fracture critical and a fatigue based service life assessment will satisfy the structural integrity requirements. Constant amplitude fatigue testing to failure on four sets of active/passive iLIDS latch hooks was performed at load magnitudes of 10, 11, and 12 kips. Failure analysis of the hook fatigue failures identified multi-site fatigue initiation that was effectively centered about the hook mid-plane (consistent with the 3D model results). The fatigue crack initiation distribution implies that the fatigue damage accumulation effectively results in a very low aspect ratio surface crack (which can be simulated as thru-thickness crack). Fatigue damage progression resulted in numerous close proximity fatigue crack initiation sites. It was not possible to determine if fatigue crack coalescence occurs during cyclic loading or as result of the fast fracture response. The presence of multiple fatigue crack initiation sites on different planes will result in the formation of ratchet marks as the cracks coalesce. Once the stable fatigue crack becomes unstable and the fast fracture advances across the remaining ligament and the plane stress condition at a free-surface will result in failure along a 45 deg. shear plane (slant fracture) and the resulting inclined edge is called a shear lip. The hook thickness on the plane of fatigue crack initiation is 0.787". The distance between the shear lips on this plane was on the order of 0

  17. The restoring force on a dielectric in a parallel plate capacitor

    NASA Astrophysics Data System (ADS)

    Staunton, L. P.

    2014-09-01

    We investigate the restoring force on a dielectric slab being pulled from within the volume of a parallel plate capacitor connected to a battery. Using a conformal mapping to treat the fringing electric field exactly, we numerically obtain an expected Hooke's Law restoring force for small displacements, and a diminishing force for a displacement up to half the length of the dielectric.

  18. Dynamic infrared imaging analysis of apical hook development in Arabidopsis: the case of brassinosteroids.

    PubMed

    Smet, Dajo; Žádníková, Petra; Vandenbussche, Filip; Benková, Eva; Van Der Straeten, Dominique

    2014-06-01

    Germination of Arabidopsis seeds in darkness induces apical hook development, based on a tightly regulated differential growth coordinated by a multiple hormone cross-talk. Here, we endeavoured to clarify the function of brassinosteroids (BRs) and cross-talk with ethylene in hook development. An automated infrared imaging system was developed to study the kinetics of hook development in etiolated Arabidopsis seedlings. To ascertain the photomorphogenic control of hook opening, the system was equipped with an automatic light dimmer. We demonstrate that ethylene and BRs are indispensable for hook formation and maintenance. Ethylene regulation of hook formation functions partly through BRs, with BR feedback inhibition of ethylene action. Conversely, BR-mediated extension of hook maintenance functions partly through ethylene. Furthermore, we revealed that a short light pulse is sufficient to induce rapid hook opening. Our dynamic infrared imaging system allows high-resolution, kinetic imaging of up to 112 seedlings in a single experimental run. At this high throughput, it is ideally suited to rapidly gain insight in pathway networks. We demonstrate that BRs and ethylene cooperatively regulate apical hook development in a phase-dependent manner. Furthermore, we show that light is a predominant regulator of hook opening, inhibiting ethylene- and BR-mediated postponement of hook opening. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  19. [Case-control study on shoulder pain caused by hook palte for the treatment of acromioclavicular joint dislocation].

    PubMed

    Yang, Ying-guo; Cai, Xiao-bing; Wang, Xiao-min; Zhu, Yong-gan; Pan, He-yong

    2015-06-01

    To explore causes of shoulder pain and propose prevention measures in treating acromioclavicular joint dislocation. From January 2005 to January 2013, 86 patients with acromioclavicular joint dislocation (Tossy III) were treated with hook plate fixation, and were divided into two groups. Bsaed on recovery of shoulder function mostly, the patients who suffered from rest pain, motion pain were named as shoulder pain group, while the patients without pain were named as painless group. In shoulder pain group, there were 21 cases including 15 males and and 6 females ranging the age from 22 to 62 years old with an average of (40.6±11.2) years old. There were 8 cases were on the left side and 13 cases were on the right side. In painless group, there were 65 cases including 36 males and and 29 females ranging the age from 19 to 65 years old with an average of (40.0±11.3) years old. There were 33 cases were on the left side and 32 cases were on the right side. The time from injury to operation ranged from 3 h to 8 d with an average of 34.6 h. Shoulder function of all patients were normal before injuried. Postoperative pain, activity of daily living (ADL), range of motion, deltoid muscle strength were compared. Anteflexion,rear protraction, abduction and upthrow of shoulder joint were also compared. Postoperative complications between two groups were observed and compared. All patients were followed up from 12 to 48 months with an average of 18.5 months. Constant-Murley score were used to evaluate clinical efficacy at the least following up, and 13 cases got an excellent results, 5 moderate, 2 good and 1 poor in shoulder pain group ; while 61 cases were obtained excellent results, 3 moderate and 1 good in painless group. There were significantly differences between two groups in Constant-Murley score and activity of shoulder joint (P<0.05). In shoulder pain group, 3 cases were disconnected, 1 case occurred stress fracture, 9 cases were subacromial impingement syndrome, 5

  20. 75 FR 4265 - Airworthiness Directives; Lifesavings Systems Corp., D-Lok Hook Assembly

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... Airworthiness Directives; Lifesavings Systems Corp., D-Lok Hook Assembly AGENCY: Federal Aviation Administration... adopting a new airworthiness directive (AD) for the Lifesavings Systems Corp., D-Lok Hook assembly... reported surface irregularities and discontinuities on certain D-Lok Hooks because of an unapproved change...

  1. Kinematics of Hooke universal joint robot wrists

    NASA Technical Reports Server (NTRS)

    Mckinney, William S., Jr.

    1988-01-01

    The singularity problem associated with wrist mechanisms commonly found on industrial manipulators can be alleviated by redesigning the wrist so that it functions as a three-axis gimbal system. This paper discussess the kinematics of gimbal robot wrists made of one and two Hooke universal joints. Derivations of the resolved rate motion control equations for the single and double Hooke universal joint wrists are presented using the three-axis gimbal system as a theoretical wrist model.

  2. Interdependence of the rad50 hook and globular domain functions.

    PubMed

    Hohl, Marcel; Kochańczyk, Tomasz; Tous, Cristina; Aguilera, Andrés; Krężel, Artur; Petrini, John H J

    2015-02-05

    Rad50 contains a conserved Zn(2+) coordination domain (the Rad50 hook) that functions as a homodimerization interface. Hook ablation phenocopies Rad50 deficiency in all respects. Here, we focused on rad50 mutations flanking the Zn(2+)-coordinating hook cysteines. These mutants impaired hook-mediated dimerization, but recombination between sister chromatids was largely unaffected. This may reflect that cohesin-mediated sister chromatid interactions are sufficient for double-strand break repair. However, Mre11 complex functions specified by the globular domain, including Tel1 (ATM) activation, nonhomologous end joining, and DNA double-strand break end resection were affected, suggesting that dimerization exerts a broad influence on Mre11 complex function. These phenotypes were suppressed by mutations within the coiled-coil and globular ATPase domains, suggesting a model in which conformational changes in the hook and globular domains are transmitted via the extended coils of Rad50. We propose that transmission of spatial information in this manner underlies the regulation of Mre11 complex functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Modeling the hook depth distribution of pelagic longlining in the equatorial area of Indian Ocean

    NASA Astrophysics Data System (ADS)

    Song, Liming; Li, Jie; Gao, Panfeng; Zhou, Ji; Xu, Liuxiong

    2012-12-01

    A survey was conducted in the equatorial area of Indian Ocean for a better understanding of the dynamics of hook depth distribution of pelagic longline fishery. We determined the relationship between hook depth and vertical shear of current coefficiency, wind speed, hook position code, sine of wind angle, sine of angle of attack and weight of messenger weight. We identified the hook depth models by the analysis of covariance with a general linear model. The results showed that the wind effect on the hook depth can be ignored from October to November in the survey area; the surface current effect on the hook depth can be ignored; the equatorial undercurrent is the key factor for the hook depth in Indian Ocean; and there is a negative correlation between the hook depth and vertical shear of current and angle of attack. It was also found that the deeper the hook was set, the higher hook depth shoaling was. The proposed model improves the accuracy of the prediction of hook depth, which can be used to estimate the vertical distribution of pelagic fish in water column.

  4. The dynamic instability in the hook/flagellum system that triggers bacterial flicks

    NASA Astrophysics Data System (ADS)

    Jabbarzadeh, Mehdi; Fu, Henry

    2017-11-01

    Dynamical bending, buckling, and polymorphic transformations of the flagellum are known to affect bacterial motility, but run-reverse-flick motility of monotrichous bacteria also involves the even more flexible hook, which connects the flagellum to the cell body. Here, we identify the dynamic buckling mechanism that produces flicks in Vibrio alginolyticus. Estimates of forces and torques on the hook from experimental observations suggest that flicks are triggered at stresses below the hook's static Euler buckling criterion. Using an accurate linearization of the Kirchoff rod model for the hook in a model of a swimming bacterium with rigid flagellum, we show that as hook stiffness decreases there is a transition from on-axis flagellar rotation with small hook deflections to flagellar precession with large deflections. When flagellum flexibility is incorporated, the precession is disrupted by significant flagellar bending - i.e., incipient flicks. The predicted onset of dynamic instabilities corresponds well with experimentally observed flick events.

  5. Study on The Geopolymer Concrete Properties Reinforced with Hooked Steel Fiber

    NASA Astrophysics Data System (ADS)

    Abdullah, M. M. A. B.; Tahir, M. F. M.; Tajudin, M. A. F. M. A.; Ekaputri, J. J.; Bayuaji, R.; Khatim, N. A. M.

    2017-11-01

    In this research, Class F fly ash and a mixture of alkaline activators and different amount of hooked steel fiber were used for preparing geopolymer concrete. In order to analyses the effect of hooked steel fiber on the geopolymer concrete, the analysis such as chemical composition of fly ash, workability of fresh geopolymer, water absorption, density, compressive strength of hardened geopolymer concrete have been carried out. Mixtures were prepared with fly ash to alkaline liquid ratio of 2.0 with hooked steel fibers were added to the mix with different amounts which are 1%, 3%, 5% and 7% by the weight of the concrete. Experimental results showed that the compressive strength of geopolymer concrete increases as the hooked steel fibers increases. The optimum compressive strength obtained was up to 87.83 MPa on the 14th day. The density of geopolymer concrete are in the range between 2466 kg/m3 to 2501 kg/m3. In addition, the workability value of geopolymer without hooked steel fibers is 100 mm while the workability value of geopolymer with hooked steel fibers are between 60 mm to 30 mm.

  6. A Model of Differential Growth-Guided Apical Hook Formation in Plants

    PubMed Central

    Žádníková, Petra; Wabnik, Krzysztof; Abuzeineh, Anas; Prusinkiewicz, Przemysław

    2016-01-01

    Differential cell growth enables flexible organ bending in the presence of environmental signals such as light or gravity. A prominent example of the developmental processes based on differential cell growth is the formation of the apical hook that protects the fragile shoot apical meristem when it breaks through the soil during germination. Here, we combined in silico and in vivo approaches to identify a minimal mechanism producing auxin gradient-guided differential growth during the establishment of the apical hook in the model plant Arabidopsis thaliana. Computer simulation models based on experimental data demonstrate that asymmetric expression of the PIN-FORMED auxin efflux carrier at the concave (inner) versus convex (outer) side of the hook suffices to establish an auxin maximum in the epidermis at the concave side of the apical hook. Furthermore, we propose a mechanism that translates this maximum into differential growth, and thus curvature, of the apical hook. Through a combination of experimental and in silico computational approaches, we have identified the individual contributions of differential cell elongation and proliferation to defining the apical hook and reveal the role of auxin-ethylene crosstalk in balancing these two processes. PMID:27754878

  7. Relationship between tornadoes and hook echoes on April 3, 1974

    NASA Technical Reports Server (NTRS)

    Forbes, G. S.

    1975-01-01

    Radar observations of tornado families occurring on April 3, 1974 are discussed. Of the 93 tornadoes included in the sample, 81% were associated with hook-like echoes with appendages at least 40 deg to the south of the echo movement. At least one tornado was associated with 62% of the hook-like echoes observed. All of the tornadoes with intensities of F 4 and F 5 were produced by hook-like echoes; the mean intensity of all tornadoes associated with this type of echo was F 3, while the mean intensity of the remaining tornadoes was F1. The tornadic hook-like echoes moved to the right of the non-tornadic echoes forming a tornado line in advance of the squall line. Some tornadoes were associated with 'spiral' echoes.

  8. Assessment of skeletal maturity in scoliosis patients to determine clinical management: a new classification scheme using distal radius and ulna radiographs.

    PubMed

    Luk, Keith D K; Saw, Lim Beng; Grozman, Samuel; Cheung, Kenneth M C; Samartzis, Dino

    2014-02-01

    Assessment of skeletal maturity in patients with adolescent idiopathic scoliosis (AIS) is important to guide clinical management. Understanding growth peak and cessation is crucial to determine clinical observational intervals, timing to initiate or end bracing therapy, and when to instrument and fuse. The commonly used clinical or radiologic methods to assess skeletal maturity are still deficient in predicting the growth peak and cessation among adolescents, and bone age is too complicated to apply. To address these concerns, we describe a new distal radius and ulna (DRU) classification scheme to assess skeletal maturity. A prospective study. One hundred fifty young, female AIS patients with hand x-rays and no previous history of spine surgery from a single institute were assessed. Radius and ulna plain radiographs, and various anthropomorphic parameters were assessed. We identified various stages of radius and ulna epiphysis maturity, which were graded as R1-R11 for the radius and U1-U9 for the ulna. The bone age, development of sexual characteristics, standing height, sitting height, arm span, radius length, and tibia length were studied prospectively at each stage of these epiphysis changes. Standing height, sitting height, and arm span growth were at their peak during stages R7 (mean, 11.4 years old) and U5 (mean, 11.0 years old). The long bone growths also demonstrated a common peak at R7 and U5. Cessation of height and arm span growth was noted after stages R10 (mean, 15.6 years old) and U9 (mean, 17.3 years old). The new DRU classification is a practical and easy-to-use scheme that can provide skeletal maturation status. This classification scheme provides close relationship with adolescent growth spurt and cessation of growth. This classification may have a tremendous utility in improving clinical-decision making in the conservative and operative management of scoliosis patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Stainless hooks to bond lower lingual retainer.

    PubMed

    Durgekar, Sujala G; Nagaraj, K

    2011-01-01

    We introduced a simple and economical technique for precise placement of lower lingual retainers. Two stainless steel hooks made of 0.6mm wire are placed interdentally in the embrasure area between canine and lateral incisor bilaterally to lock the retainer wire in the correct position. Etch, rinse and dry the enamel surfaces with the retainer passively in place, then bond the retainer with light-cured adhesive. Hooks are simple to fabricate and eliminate the need for a transfer tray.

  10. Cooperative binding mitigates the high-dose hook effect.

    PubMed

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  11. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.

    PubMed

    Boden, Allison L; Daly, Charles A; Dalwadi, Poonam P; Boden, Stephanie A; Hutton, William C; Muppavarapu, Raghuveer C; Gottschalk, Michael B

    2018-01-01

    Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.

  12. Role of PIN-mediated auxin efflux in apical hook development of Arabidopsis thaliana.

    PubMed

    Zádníková, Petra; Petrásek, Jan; Marhavy, Peter; Raz, Vered; Vandenbussche, Filip; Ding, Zhaojun; Schwarzerová, Katerina; Morita, Miyo T; Tasaka, Masao; Hejátko, Jan; Van Der Straeten, Dominique; Friml, Jirí; Benková, Eva

    2010-02-01

    The apical hook of dark-grown Arabidopsis seedlings is a simple structure that develops soon after germination to protect the meristem tissues during emergence through the soil and that opens upon exposure to light. Differential growth at the apical hook proceeds in three sequential steps that are regulated by multiple hormones, principally auxin and ethylene. We show that the progress of the apical hook through these developmental phases depends on the dynamic, asymmetric distribution of auxin, which is regulated by auxin efflux carriers of the PIN family. Several PIN proteins exhibited specific, partially overlapping spatial and temporal expression patterns, and their subcellular localization suggested auxin fluxes during hook development. Genetic manipulation of individual PIN activities interfered with different stages of hook development, implying that specific combinations of PIN genes are required for progress of the apical hook through the developmental phases. Furthermore, ethylene might modulate apical hook development by prolonging the formation phase and strongly suppressing the maintenance phase. This ethylene effect is in part mediated by regulation of PIN-dependent auxin efflux and auxin signaling.

  13. Sandy Hook : alternative access concept plan and vehicle replacement study

    DOT National Transportation Integrated Search

    2009-06-01

    This study addresses two critical issues of concern to the Sandy Hook Unit of Gateway National : Recreational Area: (1) options for alternative access to Sandy Hook during peak summer season, : particularly when the park is closed to private vehicles...

  14. The effects of flagellar hook compliance on motility of monotrichous bacteria: A modeling study

    NASA Astrophysics Data System (ADS)

    Shum, H.; Gaffney, E. A.

    2012-06-01

    A crucial structure in the motility of flagellated bacteria is the hook, which connects the flagellum filament to the motor in the cell body. Early mathematical models of swimming bacteria assume that the helically shaped flagellum rotates rigidly about its axis, which coincides with the axis of the cell body. Motivated by evidence that the hook is much more flexible than the rest of the flagellum, we develop a new model that allows a naturally straight hook to bend. Hook dynamics are based on the Kirchhoff rod model, which is combined with a boundary element method for solving viscous interactions between the bacterium and the surrounding fluid. For swimming in unbounded fluid, we find good support for using a rigid model since the hook reaches an equilibrium configuration within several revolutions of the motor. However, for effective swimming, there are constraints on the hook stiffness relative to the scale set by the product of the motor torque with the hook length. When the hook is too flexible, its shape cannot be maintained and large deformations and stresses build up. When the hook is too rigid, the flagellum does not align with the cell body axis and the cell "wobbles" with little net forward motion. We also examine the attraction of swimmers to no-slip surfaces and find that the tendency to swim steadily close to a surface can be very sensitive to the combination of the hook rigidity and the precise shape of the cell and flagellum.

  15. Development and impact of hooks of high droplet concentration on remote southeast Pacific stratocumulus

    NASA Astrophysics Data System (ADS)

    George, R. C.; Wood, R.; Bretherton, C. S.; Painter, G.

    2013-07-01

    Over the southeastern Pacific (SEP), droplet concentration (Nd) in the typically unpolluted marine stratocumulus west of 80° W (> 1000 km offshore) is periodically strongly enhanced in zonally elongated "hook"-shaped features that increase albedo. Here, we examine three hook events using the chemistry version of the Weather Research and Forecasting model (WRF-Chem) with 14 km horizontal resolution, satellite data, and aircraft data from the VAMOS Ocean-Cloud-Atmosphere-Land Study Regional Experiment (VOCALS-REx). A particularly strong hook yields insights into the development, decay, and radiative impact of these features. Hook development occurs with Nd increasing to polluted levels over the remote ocean primarily due to entrainment of cloud condensation nuclei (CCN) from the lower free troposphere (FT). The feature advects northwestward until the FT CCN source is depleted, after which Nd decreases over a few days due to precipitation and dilution. The model suggests that the FT CCN source supplying the hook consists of high concentrations of small accumulation-mode aerosols that contribute a relatively small amount of aerosol mass to the MBL, in agreement with near-coast VOCALS measurements of polluted layers in the FT. The aerosol particles in this hook originate mainly from a pulse of offshore flow that transports Santiago-region (33-35° S) emissions to the remote marine FT. To provide pollution CCN that can sustain hooks, the FT transport of pollution plumes to the remote ocean requires strong, deep offshore flow. Such flow is favored by a trough approaching the South American coast and a southeastward shift of the climatological subtropical high-pressure system. The model simulations show precipitation suppression in the hook and a corresponding increase in liquid water path (LWP) compared with a simulation without anthropogenic sources. LWP also increases as the hook evolves over time due to increasing stability and decreasing subsidence. WRF-Chem suggests

  16. Dimensional threshold for fracture linkage and hooking

    NASA Astrophysics Data System (ADS)

    Lamarche, Juliette; Chabani, Arezki; Gauthier, Bertrand D. M.

    2018-03-01

    Fracture connectivity in rocks depends on spatial properties of the pattern including length, abundance and orientation. When fractures form a single-strike set, they hardly cross-cut each other and the connectivity is limited. Linkage probability increases with increasing fracture abundance and length as small fractures connect to each other to form longer ones. A process for parallel fracture linkage is the "hooking", where two converging fracture tips mutually deviate and then converge to connect due to the interaction of their crack-tip stresses. Quantifying the processes and conditions for fracture linkage in single-strike fracture sets is crucial to better predicting fluid flow in Naturally Fractured Reservoirs. For 1734 fractures in Permian shales of the Lodève Basin, SE France, we measured geometrical parameters in 2D, characterizing three stages of the hooking process: underlapping, overlapping and linkage. We deciphered the threshold values, shape ratios and limiting conditions to switch from one stage to another one. The hook set up depends on the spacing (S) and fracture length (Lh) with the relation S ≈ 0.15 Lh. Once the hooking is initiated, with the fracture deviation length (L) L ≈ 0.4 Lh, the fractures reaches the linkage stage only when the spacing is reduced to S ≈ 0.02 Lh and the convergence (C) is < 0.1 L. These conditions apply to multi-scale fractures with a shape ratio L/S = 10 and for fracture curvature of 10°-20°.

  17. Reflections on Sandy Hook

    ERIC Educational Resources Information Center

    Trump, Kenneth S.

    2013-01-01

    In this article, the author shares his thoughts for district administrators regarding the Sandy Hook Elementary school tragedy. Administrators heard a lot of potential solutions or attempts at solutions. However, these proposals raise lengthy lists of implementation questions and issues that illustrate a lack of understanding of school operations,…

  18. Bohlin transformation: the hidden symmetry that connects Hooke to Newton

    NASA Astrophysics Data System (ADS)

    Saggio, Maria Luisa

    2013-01-01

    Hooke's name is familiar to students of mechanics thanks to the law of force that bears his name. Less well-known is the influence his findings had on the founder of mechanics, Isaac Newton. In a lecture given some twenty years ago, W Arnol'd pointed out the outstanding contribution to science made by Hooke, and also noted the controversial issue of the attribution of important discoveries to Newton that were actually inspired by Hooke. It therefore seems ironic that the two most famous force laws, named after Hooke and Newton, are two geometrical aspects of the same law. This relationship, together with other illuminating aspects of Newtonian mechanics, is described in Arnol'd's book and is worth remembering in standard physics courses. In this didactical paper the duality of the two forces is expounded and an account of the more recent contributions to the subject is given.

  19. Sandy Hook Traveler Information System

    DOT National Transportation Integrated Search

    2010-09-01

    This report focuses on equipment and procedural solutions for gathering and disseminating a wide range of visitor information, including real-time traveler information data relating to traffic and parking at the Sandy Hook Unit of the Gateway Recreat...

  20. Extreme Modification of the Tetrapod Forelimb in a Triassic Diapsid Reptile.

    PubMed

    Pritchard, Adam C; Turner, Alan H; Irmis, Randall B; Nesbitt, Sterling J; Smith, Nathan D

    2016-10-24

    The tetrapod forelimb is one of the most versatile structures in vertebrate evolution, having been co-opted for an enormous array of functions. However, the structural relationships between the bones of the forelimb have remained largely unchanged throughout the 375 million year history of Tetrapoda, with a radius and ulna made up of elongate, paralleling shafts contacting a series of shorter carpal bones. These features are consistent across nearly all known tetrapods, suggesting that the morphospace encompassed by these taxa is limited by some sort of constraint(s). Here, we report on a series of three-dimensionally preserved fossils of the small-bodied (<1 m) Late Triassic diapsid reptile Drepanosaurus, from the Chinle Formation of New Mexico, USA, which dramatically diverge from this pattern. Along with the crushed type specimen from Italy, these specimens have a flattened, crescent-shaped ulna with a long axis perpendicular to that of the radius and hyperelongate, shaft-like carpal bones contacting the ulna that are proximodistally longer than the radius. The second digit supports a massive, hooked claw. This condition has similarities to living "hook-and-pull" digging mammals and demonstrates that specialized, modern ecological roles had developed during the Triassic Period, over 200 million years ago. The forelimb bones in Drepanosaurus represent previously unknown morphologies for a tetrapod and, thus, a dramatic expansion of known tetrapod forelimb morphospace. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. The hook effect in calcitonin immunoradiometric assay: a case report.

    PubMed

    Fangous, Marie-Sarah; Kerspern, Hélène; Moineau, Marie-Pierre; Kerlan, Véronique; Alavi, Zarrin; Carré, Jean-Luc

    2012-12-01

    The hook effect, which has long been detected and documented for immunoradiometric assays (IRMA) such as those measuring prolactin or thyroglobulin, occurs when the serum antigen level is extremely high, thus inducing a bias in the methodology of measurement. We report the case of an 80-year-old man with confirmed medullary thyroid carcinoma (MTC). In the case reported here, the clinical status of the patient contrasts with his tumor antigen, serum calcitonin (CT), concentrations. The measured increased CT concentrations revealed the presence of a hook effect. This phenomenon occurs due to an excess of antigen during the one-step IRMA where the signal antibodies, bound to the non-captured antigens, are washed out during the measurement, inducing the loss of signal. Aiming to prevent the "hook effect", successive dilutions of the same sample of serum were done. Previous studies have shown when one-step IRMA reveals high concentrations of a tumor serum antigen (i.e. prolactin or thyroglobulin), a two-step IRMA or a systematic 1:10 dilution of the serum sample prevents the formation of the "hook effect". In our case report, the CT "hook effect" formation was prevented by performing serial dilutions of the serum sample. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. Development and impact of hooks of large droplet concentration on remote southeast Pacific stratocumulus

    NASA Astrophysics Data System (ADS)

    George, R. C.; Wood, R.; Bretherton, C. S.; Painter, G.

    2013-01-01

    Over the southeastern Pacific (SEP), droplet concentration (Nd) in the typically unpolluted marine stratocumulus west of 80° W (> 1000 km offshore) is periodically strongly enhanced in zonally-elongated "hook"-shaped arcs that increase albedo. Here, we examine three hook events using the chemistry version of the Weather Research and Forecasting model (WRF-Chem) with 14 km horizontal resolution, satellite data and aircraft data from the VAMOS Ocean-Cloud-Atmosphere-Land Study Regional Experiment (VOCALS-REx). A particularly strong hook yields insights to the development, decay, and radiative impact of these features. Hook development occurs with Nd increasing to polluted levels over the remote ocean primarily due to entrainment of cloud condensation nuclei (CCN) from the free troposphere (FT). The feature advects northwestward until the FT CCN source is depleted, after which Nd decreases over a few days due to precipitation and dilution. The model suggests that the FT CCN source supplying the hook consists of high concentrations of small accumulation mode aerosols that contribute a relatively small amount of aerosol mass to the MBL. The aerosol particles originate mainly from a pulse of offshore flow that transports Santiago region (33-35° S) emissions to the marine FT. To provide a sustained hook CCN source, the FT transport of pollution plumes to the remote ocean requires strong, deep offshore flow. Such flow is favored by a trough approaching the South American coast and a southeastward shift of the climatological subtropical high pressure system. The model simulations show precipitation suppression in the hook and a corresponding increase in liquid water path (LWP) compared with a simulation without anthropogenic sources. LWP also increases in time as the hook evolves due to increasing stability and decreasing subsidence. WRF-Chem suggests that DMS significantly influences the aerosol number and size distributions in a hook, but that hooks do not form without

  3. Reconstruction of the elbow and forearm for Ewing sarcoma of ulna: A new biological technique

    PubMed Central

    Puri, Ajay; Gulia, Ashish; Byregowda, Suman; Ramanujan, Vishnu

    2016-01-01

    Primary bone tumors around the elbow represent <1% of all the skeletal tumors. Surgery with or without adjuvant therapy (radiotherapy, chemotherapy) is the treatment of choice for malignant tumors. Reconstruction of the elbow and forearm in malignant tumors is challenging as it involves a complex interplay between multiple joints which need to be stabilized for the optimal functional outcome. We describe a new technique for the reconstruction of the elbow after resection of a proximal ulna tumor with articular radio-ulnar synostosis with the creation of a single bone forearm. We attempted to achieve a mobile elbow and stable wrist joint with the radio-ulnar union at the proximal articular surface of the ulna resulting in a single bone forearm. The procedure involves an oblique osteotomy preserving the olecranon process (after taking adequate margins based on oncological principles) and its articular cartilage along with the attachment of the triceps tendon. Then the radial head was partially denuded of its cartilage using a burr, leaving cartilage only on the volar side, and then fused to the remnant olecranon. Osteosynthesis was done using compression screw and tension band wiring. The advantages of this procedure are that the mobility at wrist and elbow are retained, it requires minimal hardware and allows for primary closure of the wound. PMID:27186061

  4. Aluminum Manganese Molten Salt Plating

    DTIC Science & Technology

    2006-06-01

    fixture from overhead crane hook and locate fixture over the closed acid tank. 2. Ventilation a. Set valve positions as follows (same as Section I.4.a...overhead crane hook and position the fixture over the closed acid tank. (Will need to remove the top stainless steel rod, clasp the remaining rod with the... crane hook , replace the rod that was removed by threading it through the crane hook , and finally lift the fixture off its storage hook . The cotter

  5. [ZHENG's gold hook fishing acupuncture for lumbar disc herniation: a clinical observation].

    PubMed

    Zhu, Bowen; Zhang, Xinghua; Sun, Runjie; Qin, Xiaoguang

    2016-04-01

    To compare the clinical efficacy differences between Zheng's gold hook, fishing acupuncture and electroacupuncture (EA) for lumbar disc herniation (LDH). Sixty patients of LDH were randomly allocated to a gold hook fishing acupuncture group and an EA group, 30 cases in each one. Lumbar Jiaji (EX-1 B 2), Yaoyangguan (GV 3), Shenshu (BL 23), Dachangshu (BL 25), Guanyuanshu (BL 26) and ashi points were selected in the gold hook fishing acupuncture group; after the needles were inserted, the manipulation of gold hook fishing acupuncture was applied at tendon junction points and ashi points. The identical acupoints were selected in the EA group and patients were treated with EA. The treatment was both given once a day; ten days of treatment were taken as one session, and totally 3 sessions were given. The clinical effective rate, visual analogue scale (VAS), low back pain score and Oswestry disability index (ODI) were used for efficacy evaluation. The effective rate was 93.3% (28/30) in the gold hook fishing acupuncture group, which was superior to 86.7% (26/30) in the EA group (P < 0.05). The VAS, low back pain score and ODI were both significantly improved after treatment (all P < 0.05), which were more significant in the gold hook fishing acupuncture group (all P < 0.05). ZHENG's gold hook fishing acupuncture could effectively improve the symptoms and sings of LDH, reduce the disability index and improve the quality of life, which is superior to EA.

  6. The effect of strontium ranelate on the healing of a fractured ulna with bone gap in rabbit.

    PubMed

    Ibrahim, Mohd Rafiq Mohd; Singh, Simmrat; Merican, Azhar Mahmood; Raghavendran, Hanumantha Rao Balaji; Murali, Malliga Raman; Naveen, Sangeetha Vasudevaraj; Kamarul, Tunku

    2016-06-16

    Fracture healing in bone gap is one of the major challenges encountered in Orthopedic Surgery. At present, the treatment includes bone graft, employing either internal or external fixation which has a significant impact on the patient, family and even society. New drugs are emerging in the markets such as anabolic bone-forming agents including teriparatide and strontium ranelate to stimulate bone growth. Based on the mechanism of their actions, we embarked on a study on the healing of a fractured ulna with bone gap in a rabbit model. We segregated ten rabbits into two groups: five rabbits in the test group and five rabbits in the control group. We created a 5 mm bone gap in the ulna bone, removing the periosteum as well. Rabbits in the test group received 450 mg/kg of strontium ranelate via oral administration, daily, for six weeks. The x-rays, CT scans and blood tests were performed every two weeks. At the end of six weeks, the rabbits were sacrificed, and the radius and ulna bones harvested for histopathological examination. Based on the x-rays and CT scans, fracture healing or bone formation was observed to be faster in the control group. From the x-ray findings, 80 % of the fracture united and by CT scan, 60 % of the fracture united in the control group at the end of the six-week study. None of the fractures united in the test group. However, the histopathology report showed that a callus of different stages was being formed in both groups, consisting of 80 % of bone. The serum levels of osteocalcin and alkaline phosphatase initially remained similar up to three weeks and changed slightly at the end of six weeks. We conclude that the strontium effect begins slowly, and while it may not interfere with bone cell proliferation it may interfere in the mineralization and delay the acute stage of fracture healing. We recommend that a larger sample size and a longer duration of the study period be implemented to confirm our finding.

  7. Covariant Formulation of Hooke's Law.

    ERIC Educational Resources Information Center

    Gron, O.

    1981-01-01

    Introducing a four-vector strain and a four-force stress, Hooke's law is written as a four-vector equation. This formulation is shown to clarify seemingly paradoxical results in connection with uniformly accelerated motion, and rotational motion with angular acceleration. (Author/JN)

  8. High-dose hook effect in six automated human chorionic gonadotrophin assays.

    PubMed

    Al-Mahdili, Huda A; Jones, Graham R D

    2010-07-01

    The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L. Dilutions of a sample with high hCG concentration were analysed using six common methods: Advia Centaur, Immulite 2000, Dimension RxL, Unicel DxI 800, Roche E170 and Abbott Architect. The measured concentrations and corresponding assay signals were obtained for each method. Performance was compared with manufacturer claims. Four of the tested platforms demonstrated a clear high-dose hook effect, while the other methods showed no hook effect at the highest level tested. Our results indicate that the hook effect may occur in some hCG assays, although the risk of reporting falsely low results was in most cases at higher concentrations than those indicated in manufacturers' product information. Assay design plays a major role in its occurrence. Laboratories should be aware of the assay limitations in this regard.

  9. Large amplitude flexural vibration of thin elastic flat plates and shells

    NASA Technical Reports Server (NTRS)

    Pandalia, K. A. V.

    1972-01-01

    The general equations governing the large amplitude flexural vibration of any thin elastic shell using curvilinear orthogonal coordinates are derived and consist of two coupled, nonlinear, partial differential equations in the normal displacement w and the stress function F. From these equations, the governing equations for the case of shells of revolution or flat plates can be readily obtained as special cases. The material of the shell or plate is isotropic and homogeneous and Hooke's law for the two-dimensional case is valid. It is suggested that the difference between the hardening type of nonlinearity in the case of flat plates and straight beams and the softening type of nonlinearity in the case of shells and rings can, in general, be traced to the amount of curvature present in the underformed median surface of the structure concerned.

  10. An experimental 'Life' for an experimental life: Richard Waller's biography of Robert Hooke (1705).

    PubMed

    Moxham, Noah

    2016-03-01

    Richard Waller's 'Life of Dr Robert Hooke', prefixed to his edition of Hooke's Posthumous Works (1705), is an important source for the life of one of the most eminent members of the early Royal Society. It also has the distinction of being one of the earliest biographies of a man of science to be published in English. I argue that it is in fact the first biography to embrace the subject's natural-philosophical work as the centre of his life, and I investigate Waller's reasons for adopting this strategy and his struggle with the problem of how to represent an early experimental philosopher in print. I suggest that Waller eschews the 'Christian philosopher' tradition of contemporary biography - partly because of the unusually diverse and fragmentary nature of Hooke's intellectual output - and draws instead upon the structure of the Royal Society's archive as a means of organizing and understanding Hooke's life. The most quoted phrase from Waller's biography is that Hooke became 'to a crime close and reserved' in later life; this essay argues that Waller's biographical sketch was fashioned in order to undo the effects of that reserve. In modelling his approach very closely on the structure of the society's records he was principally concerned with making Hooke's work and biography accessible, intelligible and useful to the fellowship in a context familiar to them, a context which had provided the institutional framework for most of Hooke's adult life. I argue that Waller's 'Life' was also intended to make the largest claims for Hooke's intellectual standing that the author dared in the context of the enmity between Hooke and Isaac Newton once the latter became president of the Royal Society. However, I also adduce fresh manuscript evidence that Waller actually compiled, but did not publish, a defence of Hooke's claim to have discovered the inverse square law of gravity, allowing us to glimpse a much more assertive biography of Hooke than the published version.

  11. When Teachers Aren't Nice: bell hooks and Feminist Pedagogy.

    ERIC Educational Resources Information Center

    Buffington, Nancy

    The recent "feminization" of composition theory and pedagogy has replaced the classroom figure of the authoritative father with an image of a nurturing mother. But as bell hooks and others insist, the classroom is inherently a place of struggle and conflict and the "real world" is even more so. Hooks offers concrete…

  12. Evaluation of the orientation of 90* and 180* reinforcing bar hooks.

    DOT National Transportation Integrated Search

    2012-01-01

    This report describes test results of a study initiated to evaluate the potential influence of hook tilt angle of standard reinforcing hooks : on the bond strength of concrete. The topic of the evaluation of the orientation of 90 and 180 degree reinf...

  13. Flagellar Hook Flexibility Is Essential for Bundle Formation in Swimming Escherichia coli Cells

    PubMed Central

    Brown, Mostyn T.; Steel, Bradley C.; Silvestrin, Claudio; Wilkinson, David A.; Delalez, Nicolas J.; Lumb, Craig N.; Obara, Boguslaw; Berry, Richard M.

    2012-01-01

    Swimming Escherichia coli cells are propelled by the rotary motion of their flagellar filaments. In the normal swimming pattern, filaments positioned randomly over the cell form a bundle at the posterior pole. It has long been assumed that the hook functions as a universal joint, transmitting rotation on the motor axis through up to ∼90° to the filament in the bundle. Structural models of the hook have revealed how its flexibility is expected to arise from dynamic changes in the distance between monomers in the helical lattice. In particular, each of the 11 protofilaments that comprise the hook is predicted to cycle between short and long forms, corresponding to the inside and outside of the curved hook, once each revolution of the motor when the hook is acting as a universal joint. To test this, we genetically modified the hook so that it could be stiffened by binding streptavidin to biotinylated monomers, impeding their motion relative to each other. We found that impeding the action of the universal joint resulted in atypical swimming behavior as a consequence of disrupted bundle formation, in agreement with the universal joint model. PMID:22522898

  14. 77 FR 15722 - Southern California Hook and Line Survey; Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ... meeting to evaluate the Southern California Shelf Rockfish Hook and Line Survey which was designed to... and Line survey design and protocols; (2) examine the analytical methods used to generate rockfish... California Hook and Line Survey; Public Meeting AGENCY: National Marine Fisheries Service (NMFS), National...

  15. SS Edgar M. Queeny collision with the Liberian S/T Corinthos, Marcus Hook, Pennsylvania, 31 January 1975. Marine casualty report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1977-10-27

    At 0029, on January 31, 1975, the U.S. Registered tankship SS EDGAR M. QUEENY, laden with chemical and petroleum products, was maneuvering into Marcus Hook channel of the Delaware River in Pennsylvania, when it collided with the Liberian tanker S/T CORINTHOS which was moored and discharging a bulk cargo of crude oil at the British Petroleum Company dock. The port anchor of the QUEENY slightly penetrated the port side plating of the CORINTHOS at an angle of about 39 deg. into one or more of the wing cargo tanks, which were being pumped and were approximately half full. Almost immediately,more » a series of increasingly intense explosions began in the CORINTHOS, and the vessel was engulfed in flames. Twenty-six persons were killed or are missing and 11 were injured in this accident. The QUEENY suffered minor damage but the CORINTHOS was destroyed. The Delaware River was polluted by oil about Marcus Hook. Property damage was estimated to be $20 million.« less

  16. Removal of a barbed fish hook from the cornea of an 8-year-old boy.

    PubMed

    Kemp, Pavlina S; Shah, Ankoor S; Elliott, Alexandra T; Wan, Michael J

    2017-10-01

    This video article shows the surgical removal of a three-pronged barbed fish hook from the cornea and anterior chamber of an 8-year-old boy. The advance-and-cut method is shown: the embedded barbed point of the fish hook was advanced through the cornea, its point was cut off, and the shank of the hook was withdrawn. This method was chosen due to the three-pronged configuration of the fish hook to minimize additional trauma to the eye. Other methods of fish hook removal are briefly reviewed. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  17. Are College Students Replacing Dating and Romantic Relationships with Hooking Up?

    ERIC Educational Resources Information Center

    Siebenbruner, Jessica

    2013-01-01

    This study assessed female college students' ("N" = 197) participation in dating, romantic relationships, hooking up behaviors, and the intersection of these activities. Hooking up was prevalent among students ("n" = 78; 39.6%), but dating ("n" = 139; 70.6%) and romantic relationship ("n" = 147; 74.6%)…

  18. Fluidically Controlled Cargo Hook

    DTIC Science & Technology

    1975-03-01

    Final Breadboard Fluidic Circuit IT 6 External Cargo Handling System - Cü-Sk Type Aircraft 18 7 Back Pressure Switch Response Time - Switching...On 20 8 Back Pressure Switch Response Time - Switching Off 21 9 Hook Actuator - Pressure Rise Rate 22 10 Breadboard Fluidic System Component...LINE LENGTH* FT Figure 7« Back. Pressure Switch Response Time - Switching On. ! TABLE k. INTERFACE VALVE SIGNAL TIME

  19. Prediction of femoral neck and spine bone mineral content from the BMC of the radius or ulna and the relationship between bone strength and BMC

    NASA Technical Reports Server (NTRS)

    Wilson, C. R.

    1974-01-01

    The bone mineral content (BMC) is extensively used to provide information about the status of an entire skeleton. Changes in BMC are employed to evaluate the effect of various drugs, disease states, weightlessness, exercise, renal dialysis and others on the skeleton. Clinical and functional information is discussed that may be derived from the BMC of a limited region of the skeleton. In particular there is a fairly high degree of correlation between the BMC of the radius or ulna and that of the femoral neck, r about 0.85 and a somewhat lower relationship between the BMC of the radius or ulna and the thoracic vertebrae, r about 0.65. Also the BMC is highly related to the strength of bone at that scan site.

  20. Light exaggerates apical hook curvature through phytochrome actions in tomato seedlings.

    PubMed

    Shichijo, Chizuko; Ohuchi, Hisako; Iwata, Naoko; Nagatoshi, Yukari; Takahashi, Miki; Nakatani, Eri; Inoue, Kentaroh; Tsurumi, Seiji; Tanaka, Osamu; Hashimoto, Tohru

    2010-02-01

    Contrary to the established notion that the apical hook of dark-grown dicotyledonous seedlings opens in response to light, we found in tomato (Solanum lycopersicum L.) that the apical hook curvature is exaggerated by light. Experiments with several tomato cultivars and phytochrome mutants, irradiated with red and far-red light either as a brief pulse (Rp, FRp) or continuously (Rc, FRc), revealed: the hook-exaggeration response is maximal at the emergence of the hypocotyl from the seed; the effect of Rp is FRp-reversible; fluence-response curves to a single Rp or FRp show an involvement of low and very low fluence responses (LFR, VLFR); the effect of Rc is fluence-rate dependent, but that of FRc is not; the phyA mutant (phyA hp-1) failed to respond to an Rp of less than 10(-2) micromol m(-2) and to an FRp of all fluences tested as well as to FRc, thus indicating that the hook-exaggeration response involves phyA-mediated VLFR. The Rp fluence-response curve with the same mutant also confirmed the presence of an LFR mediated by phytochrome(s) other than phyA, although the phyB1 mutant (phyB1 hp-1) still showed full response probably due to other redundant phytochrome species (e.g., phyB2). Simulation experiments led to the possible significance of hook exaggeration in the field that the photoresponse may facilitate the release of seed coat when seeds germinate at some range of depth in soil. It was also observed that seed coat and/or endosperm are essential to the hook exaggeration.

  1. The Radial Bow following Square Nailing in Radius and Ulna Shaft Fractures in Adults and its Relation to Disability and Function.

    PubMed

    Dave, M B; Parmar, K D; Sachde, B A

    2016-07-01

    One of the points made against nailing in radius and ulna shaft fractures has been the loss of radial bow and its impact on function. The aims of the study were to assess the change in magnitude and location of the radial bow in radius and ulna shaft fractures treated with intramedullary square nails and to assess the impact of this change on functional outcome, patient reported disability and the range of motion of the forearm. We measured the magnitude of radial bow and its location in the operated extremity and compared it to the uninjured side in 32 adult patients treated with intramedullary square nailing for radius and ulna shaft fractures at our institute. The mean loss of magnitude of maximum radial bow was 2.18 mm which was statistically significant by both student-T test and Mann-Whitney U test with p value less than 0.01. The location of maximum radial bow shifted distally but was statistically insignificant. The magnitude of maximum radial bow had a negative correlation with DASH score that was statistically insignificant (R=- 0.22, p=0.21). It had a positive, statistically significant correlation to the extent of supination in the operated extremity (R = 0.66, p = 0.0004). A loss of up to 2mm of radial bow did not influence the functional outcome as assessed by criteria reported by Anderson et al. The magnitude of radial bow influenced the supination of the forearm but not the final disability as measured by DASH score. Intramedullary nailing did decrease the magnitude of radial bow but a reduction of up to 2mm did not influence the functional outcome.

  2. Collaborative Lesson Hook Design in Science Teacher Education: Advancing Professional Practice

    ERIC Educational Resources Information Center

    McCauley, Veronica; Davison, Kevin; Byrne, Corinna

    2015-01-01

    This article documents the process of collaboratively developing lesson hook e-resources for science teachers to establish a community of inquiry and to strengthen the pedagogy of science teaching. The authors aim to illustrate how the development and application of strategic hooks can bridge situational interest and personal interest so that…

  3. Assessing the Personal Negative Impacts of Hooking Up Experienced by College Students: Gender Differences and Mental Health.

    PubMed

    Napper, Lucy E; Montes, Kevin S; Kenney, Shannon R; LaBrie, Joseph W

    2016-09-01

    Hooking up is a normative behavior among college students that is associated with a range of positive and negative consequences. While previous research has primarily focused on women's negative experiences of hooking up, the current study explored the relationships among hooking up behaviors, psychological distress, and a broad range of negative effects of hooking up in both male and female college students. Using a multisite sample of college students, we developed the 14-item Negative Impact of Hookups Inventory (NIHI) to assess negative health outcomes, emotional responses, and social consequences associated with hooking up. Unprotected sex and having more hookup partners were associated with greater negative experiences of hooking up. Contrary to expectations, there were no gender differences in the total number of negative hookup effects, although men reported more frequent hookups. In addition, negative impacts of hooking up were positively associated with psychological distress regardless of gender. The NIHI may offer a useful tool to assess the negative impacts of hooking up. Understanding students' hookup experiences is an important step toward developing targeted health interventions related to hooking up behavior in young adult populations.

  4. 33 CFR 80.170 - Sandy Hook, NJ to Tom's River, NJ.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Sandy Hook, NJ to Tom's River, NJ. 80.170 Section 80.170 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES COLREGS DEMARCATION LINES Atlantic Coast § 80.170 Sandy Hook, NJ to Tom's River...

  5. In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables.

    PubMed

    Hitchon, Patrick W; Brenton, Matthew D; Black, Andrew G; From, Aaron; Harrod, Jeremy S; Barry, Christopher; Serhan, Hassan; Torner, James C

    2003-07-01

    Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titaniumcables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw back-out, without vertebral fractures.

  6. Structure of the bacterial flagellar hook and implication for the molecular universal joint mechanism.

    PubMed

    Samatey, Fadel A; Matsunami, Hideyuki; Imada, Katsumi; Nagashima, Shigehiro; Shaikh, Tanvir R; Thomas, Dennis R; Chen, James Z; Derosier, David J; Kitao, Akio; Namba, Keiichi

    2004-10-28

    The bacterial flagellum is a motile organelle, and the flagellar hook is a short, highly curved tubular structure that connects the flagellar motor to the long filament acting as a helical propeller. The hook is made of about 120 copies of a single protein, FlgE, and its function as a nano-sized universal joint is essential for dynamic and efficient bacterial motility and taxis. It transmits the motor torque to the helical propeller over a wide range of its orientation for swimming and tumbling. Here we report a partial atomic model of the hook obtained by X-ray crystallography of FlgE31, a major proteolytic fragment of FlgE lacking unfolded terminal regions, and by electron cryomicroscopy and three-dimensional helical image reconstruction of the hook. The model reveals the intricate molecular interactions and a plausible switching mechanism for the hook to be flexible in bending but rigid against twisting for its universal joint function.

  7. Crafting the microworld: how Robert Hooke constructed knowledge about small things

    PubMed Central

    Lawson, Ian

    2016-01-01

    This paper investigates the way in which Robert Hooke constructed his microscopical observations. His Micrographia is justifiably famous for its detailed engravings, which communicated Hooke's observations of tiny nature to his readers, but less attention has been paid to how he went about making the observations themselves. In this paper I explore the relationship between the materiality of his instrument and the epistemic images he produced. Behind the pictures lies an array of hidden materials, and the craft knowledge it took to manipulate them. By investigating the often counter-theoretical and conflicting practices of his ingenious microscope use, I demonstrate the way in which Hooke crafted the microworld for his readers, giving insight into how early modern microscopy was understood by its practitioners and audience. PMID:27017680

  8. CRAFTING THE MICROWORLD: HOW ROBERT HOOKE CONSTRUCTED KNOWLEDGE ABOUT SMALL THINGS.

    PubMed

    Lawson, Ian

    2016-03-20

    This paper investigates the way in which Robert Hooke constructed his microscopical observations. His Micrographia is justifiably famous for its detailed engravings, which communicated Hooke's observations of tiny nature to his readers, but less attention has been paid to how he went about making the observations themselves. In this paper I explore the relationship between the materiality of his instrument and the epistemic images he produced. Behind the pictures lies an array of hidden materials, and the craft knowledge it took to manipulate them. By investigating the often counter-theoretical and conflicting practices of his ingenious microscope use, I demonstrate the way in which Hooke crafted the microworld for his readers, giving insight into how early modern microscopy was understood by its practitioners and audience.

  9. Influence of hook position on phototropic and gravitropic curvature by etiolated hypocotyls of Arabidopsis thaliana

    NASA Technical Reports Server (NTRS)

    Khurana, J. P.; Best, T. R.; Poff, K. L.

    1989-01-01

    Phototropic and gravitropic curvature by hypocotyls of Arabidopsis thaliana is minimal when the side of the hook with the cotyledons attached is positioned toward the direction of tropistic curvature, and maximal when that side of the hook is positioned away from the direction of tropistic curvature. Based on these data, it is proposed that the position of the hook with attached cotyledons affects curvature and not stimulus perception. A randomly oriented population of plants exhibited considerable heterogeneity in tropistic curvature. This heterogeneity arises at least in part from the dependence of curvature on the position of the hook.

  10. Influence of hook position on phototropic and gravitropic curvature by etiolated hypocotyls of Arabidopsis thaliana.

    PubMed

    Khurana, J P; Best, T R; Poff, K L

    1989-01-01

    Phototropic and gravitropic curvature by hypocotyls of Arabidopsis thaliana is minimal when the side of the hook with the cotyledons attached is positioned toward the direction of tropistic curvature, and maximal when that side of the hook is positioned away from the direction of tropistic curvature. Based on these data, it is proposed that the position of the hook with attached cotyledons affects curvature and not stimulus perception. A randomly oriented population of plants exhibited considerable heterogeneity in tropistic curvature. This heterogeneity arises at least in part from the dependence of curvature on the position of the hook.

  11. Hook Region Represented in a Cochlear Model

    NASA Astrophysics Data System (ADS)

    Steele, Charles R.; Kim, Namkeun; Puria, Sunil

    2009-02-01

    The present interest is in discontinuities. Particularly the geometry of the hook region, with the flexible round window nearly parallel with the basilar membrane, is not represented by a standard box model, in which both stapes and round window are placed at the end. A better model represents the round window by a soft membrane in the wall of scala tympani, with the end closed. This complicates the analysis considerably. Features are that the significant compression wave, i.e., the fast wave, is of negligible magnitude in this region, and that significant evanescent waves occur because of the discontinuities at the beginning and end of the simulated round window. The effect of this on both high frequency, with maximum basilar membrane response in the hook region, and lower frequencies are determined.

  12. [Comparison between J-hook and micro-implant anchorage in the treatment of patients with bimaxillary protrusion].

    PubMed

    Chen, Wen-Jing; Li, Qing-Yi; Gong, Ai-Xiu; Hu, Fang; Gu, Yong-Jia

    2008-02-01

    To compare the difference between J-hook and micro-implant anchorage in the treatment of patient with bimaxillary protrusion. Thirty patients with bimaxillary protrusion were divided into two groups (J-hook and micro-implant groups) and treated with MBT appliance. Four first premolars were extracted in all patients. Cephalometric analyses were carried out before and after treatment. In J-hook group and micro-implant group,computerized cephalometric analysis revealed that before treatment U6C-PP was (12.4 +/- 0.2) mm and (12.5 +/- 0.1) mm, respectively,and after treatment U6C-PP was (12.6 +/- 0.1) mm and (12.8 +/- 0.1) mm,respectively. The difference between J-hook group and microimplant group was significant (P < 0.01). The other differences of cephalometric analyses between J-hook group and micro-implant group was not significant. Both J-hook and micro-implant could provide adequate anchorage in the treatment of patients with bimaxillary protrusion.

  13. The role of imaging in diagnosing diseases of the distal radioulnar joint, triangular fibrocartilage complex, and distal ulna.

    PubMed

    Squires, Judy H; England, Eric; Mehta, Kaushal; Wissman, Robert D

    2014-07-01

    The purpose of this article is to review the anatomy, biomechanics, and multimodality imaging findings of common and uncommon distal radioulnar joint (DRUJ), triangular fibrocartilage complex, and distal ulna abnormalities. The DRUJ is a common site for acute and chronic injuries and is frequently imaged to evaluate chronic wrist pain, forearm dysfunction, and traumatic forearm injury. Given the complex anatomy of the wrist, the radiologist plays a vital role in the diagnosis of wrist pain and dysfunction.

  14. Performance Outcomes After Hook of Hamate Fractures in Major League Baseball Players.

    PubMed

    Guss, Michael S; Begly, John P; Ramme, Austin J; Taormina, David P; Rettig, Michael E; Capo, John T

    2017-07-17

    Major League Baseball (MLB) players are at risk of hook of hamate fractures. There is a paucity of data assessing the effect of a hook of hamate fracture on MLB players' future athletic performance. To determine if MLB players who sustain hook of hamate fractures demonstrate decreased performance upon return to competition when compared with their performance before injury and that of their control-matched peers. Retrospective Case-Control Design. Retrospective Database Study. 18 MLB players who sustained hook of hamate fractures. Data for 18 MLB players with hook of hamate fractures incurred over 26 seasons (1989 to 2014) were obtained from injury reports, press releases, and player profiles ( www.mlb.com and www.baseballreference.com ). Player age, position, number of years in the league, mechanism of injury and treatment were recorded. Individual season statistics for the two seasons immediately prior to injury and the two seasons after injury for the main performance variable - wins above replacement (WAR) were obtained. Eighteen controls matched by player position, age, and performance statistics were identified. A performance comparison of the cohorts was performed. Post-injury performance compared to pre-injury performance and matched-controls. Mean age at the time of injury was 25.1 years with a mean of 4.4 seasons of MLB experience prior to injury. All injuries were sustained to their nondominant batting hand. All players underwent operative intervention. There was no significant change in WAR or ISO when pre-injury and post-injury performance was compared. When compared with matched-controls, no significant decline in performance in WAR the first season and second season after injury was found. MLB players sustaining hook of hamate fractures can reasonably expect to return to their pre-injury performance levels following operative treatment.

  15. A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation

    PubMed Central

    van Laar, Wilbert; Meester, Rinse J.; Smit, Theo H.

    2007-01-01

    Regular hooks lack initial fixation to the spine during spinal deformity surgery. This runs the risk of posterior hook dislodgement during manipulation and correction of the spinal deformity, that may lead to loss of correction, hook migration, and post-operative junctional kyphosis. To prevent hook dislodgement during surgery, a self-retaining pedicle hook device (SPHD) is available that is made up of two counter-positioned hooks forming a monoblock posterior claw device. The initial segmental posterior fixation strength of a SPHD, however, is unknown. A biomechanical pull-out study of posterior segmental spinal fixation in a cadaver vertebral model was designed to investigate the axial pull-out strength for a SPHD, and compared to the pull-out strength of a pedicle screw. Ten porcine lumbar vertebral bodies were instrumented in pairs with two different instrumentation constructs after measuring the bone mineral density of each individual vertebra. The instrumentation constructs were extracted employing a material testing system using axial forces. The maximum pull-out forces were recorded at the time of the construct failure. Failure of the SPHD appeared in rotation and lateral displacement, without fracturing of the posterior structures. The average pull-out strength of the SPHD was 236 N versus 1,047 N in the pedicle screws (P < 0.001). The pull-out strength of the pedicle screws showed greater correlation with the BMC compared to the SPHD (P < 0.005). The SPHD showed to provide a significant inferior segmental fixation to the posterior spine in comparison to pedicle screw fixation. Despite the beneficial characteristics of the monoblock claw construct in a SPHD, that decreases the risk of posterior hook dislodgement during surgery compared to regular hooks, the SPHD does not improve the pull-out strength in such a way that it may provide a biomechanically solid alternative to pedicle screw fixation in the posterior spine. PMID:17203270

  16. The hooked element in the pes of turtles (Testudines): a global approach to exploring primary and secondary homology

    PubMed Central

    Joyce, Walter G; Werneburg, Ingmar; Lyson, Tyler R

    2013-01-01

    The hooked element in the pes of turtles was historically identified by most palaeontologists and embryologists as a modified fifth metatarsal, and often used as evidence to unite turtles with other reptiles with a hooked element. Some recent embryological studies, however, revealed that this element might represent an enlarged fifth distal tarsal. We herein provide extensive new myological and developmental observations on the hooked element of turtles, and re-evaluate its primary and secondary homology using all available lines of evidence. Digital count and timing of development are uninformative. However, extensive myological, embryological and topological data are consistent with the hypothesis that the hooked element of turtles represents a fusion of the fifth distal tarsal with the fifth metatarsal, but that the fifth distal tarsal dominates the hooked element in pleurodiran turtles, whereas the fifth metatarsal dominates the hooked element of cryptodiran turtles. The term ‘ansulate bone’ is proposed to refer to hooked elements that result from the fusion of these two bones. The available phylogenetic and fossil data are currently insufficient to clarify the secondary homology of hooked elements within Reptilia. PMID:24102560

  17. Gap compression/extension mechanism of bacterial flagellar hook as the molecular universal joint.

    PubMed

    Furuta, Tadaomi; Samatey, Fadel A; Matsunami, Hideyuki; Imada, Katsumi; Namba, Keiichi; Kitao, Akio

    2007-03-01

    Bacterial flagellar hook acts as a molecular universal joint, transmitting torque produced by the flagellar basal body, a rotary motor, to the flagellar filament. The hook forms polymorphic supercoil structures and can be considered as an assembly of 11 circularly arranged protofilaments. We investigated the molecular mechanism of the universal joint function of the hook by a approximately two-million-atom molecular dynamics simulation. On the inner side of the supercoil, protein subunits are highly packed along the protofilament and no gaps remain for further compression, whereas subunits are slightly separated and are hydrogen bonded through one layer of water molecules on the outer side. As for the intersubunit interactions between protofilaments, subunits are packed along the 6-start helix in a left-handed supercoil whereas they are highly packed along the 5-start helix in a right-handed supercoil. We conclude that the supercoiled structures of the hook in the left- and right-handed forms make maximal use of the gaps between subunits, which we call "gap compression/extension mechanism". Mutual sliding of subunits at the subunit interface accompanying rearrangements of intersubunit hydrogen bonds is interpreted as a mechanism to allow continuous structural change of the hook during flagellar rotation at low energy cost.

  18. Talk about "hooking up": the influence of college student social networks on nonrelationship sex.

    PubMed

    Holman, Amanda; Sillars, Alan

    2012-01-01

    This research considers how communication within college student social networks may encourage high-risk sexual relationships. Students (n = 274) described sexual scripts for hooking up and reported on peer communication, sexual behavior, and sexual attitudes. Students described varied hookup scripts, expressed ambivalent attitudes, and reported moderate participation in hookups overall. However, the most common hookup script, suggesting high-risk sexual activity (i.e., unplanned, inebriated sex), was featured in most accounts of students who themselves participated in hookups. Students overestimated how often others were hooking up, and these estimates were especially inflated by students who frequently talked about hooking up with friends. Among students with strong ties to peers, frequent peer communication about sex predicted participation in hookups and favorable attitudes about hooking up. Peer approval also predicted hookup behavior and attitudes.

  19. Increased torsional stability by a novel femoral neck locking plate. The role of plate design and pin configuration in a synthetic bone block model.

    PubMed

    Brattgjerd, Jan Egil; Loferer, Martin; Niratisairak, Sanyalak; Steen, Harald; Strømsøe, Knut

    2018-06-01

    In undisplaced femoral neck fractures, internal fixation remains the main treatment, with mechanical failure as a frequent complication. As torsional stable fixation promotes femoral neck fracture healing, the Hansson Pinloc® System with a plate interlocking pins, was developed from the original hook pins. Since its effect on torsional stability is undocumented, the novel implant was compared with the original configurations. Forty-two proximal femur models custom made of two blocks of polyurethane foam were tested. The medial block simulated the cancellous head, while the lateral was laminated with a glass fiber filled epoxy sheet simulating trochanteric cortical bone. Two hollow metal cylinders with a circumferential ball bearing in between mimicked the neck, with a perpendicular fracture in the middle. Fractures were fixated by two or three independent pins or by five configurations involving the interlocking plate (two pins with an optional peg in a small plate, or three pins in a small, medium or large plate). Six torsional tests were performed on each configuration to calculate torsional stiffness, torque at failure and failure energy. The novel configurations improved parameters up to an average of 12.0 (stiffness), 19.3 (torque) and 19.9 (energy) times higher than the original two pins (P < 0.001). The plate, its size and its triangular configuration improved all parameters (P = 0.03), the plate being most effective, also preventing permanent failure (P < 0.001). The novel plate design with its pin configuration enhanced torsional stability. To reveal clinical relevance a clinical study is planned. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. The M-T Hook Structure Is Critical for Design of HIV-1 Fusion Inhibitors*

    PubMed Central

    Chong, Huihui; Yao, Xue; Sun, Jianping; Qiu, Zonglin; Zhang, Meng; Waltersperger, Sandro; Wang, Meitian; Cui, Sheng; He, Yuxian

    2012-01-01

    CP621-652 is a potent HIV-1 fusion inhibitor peptide derived from the C-terminal heptad repeat of gp41. We recently identified that its N-terminal residues Met-626 and Thr-627 adopt a unique hook-like structure (termed M-T hook) thus stabilizing the interaction of the inhibitor with the deep pocket on the N-terminal heptad repeat. In this study, we further demonstrated that the M-T hook structure is a key determinant of CP621-652 in terms of its thermostability and anti-HIV activity. To directly define the structure and function of the M-T hook, we generated the peptide MT-C34 by incorporating Met-626 and Thr-627 into the N terminus of the C-terminal heptad repeat-derived peptide C34. The high resolution crystal structure (1.9 Å) of MT-C34 complexed by an N-terminal heptad repeat-derived peptide reveals that the M-T hook conformation is well preserved at the N-terminal extreme of the inhibitor. Strikingly, addition of two hook residues could dramatically enhance the binding affinity and thermostability of 6-helix bundle core. Compared with C34, MT-C34 exhibited significantly increased activity to inhibit HIV-1 envelope-mediated cell fusion (6.6-fold), virus entry (4.5-fold), and replication (6-fold). Mechanistically, MT-C34 had a 10.5-fold higher increase than C34 in blocking 6-helix bundle formation. We further showed that MT-C34 possessed higher potency against T20 (Enfuvirtide, Fuzeon)-resistant HIV-1 variants. Therefore, this study provides convincing data for our proposed concept that the M-T hook structure is critical for designing HIV-1 fusion inhibitors. PMID:22879603

  1. Application of Rubber Band with Hooks on Both Ends for Vagus Nerve Stimulator Implantation.

    PubMed

    Hosoyama, Hiroshi; Hanaya, Ryosuke; Otsubo, Toshiaki; Sato, Masanori; Kashida, Yumi; Sugata, Sei; Katagiri, Masaya; Iida, Koji; Arita, Kazunori

    2018-03-01

    Vagus nerve stimulation (VNS) is a valuable therapeutic option for many types of drug-resistant epilepsy. Muscle hooks and carotid endarterectomy rings have been used for cervical delamination preceding the implantation of stimulation electrodes. The attachment on both sides of a rubber band of Kamiyama-style hanging needles, as are used for scalp and dural retraction during craniotomy, yields a useful tool for VNS implantation. Here we report our experience with this method. We present our method using a rubber band plus hooks and a review of 21 consecutive patients who underwent VNS implantation using our rubber band-plus-hooks method. None of the 21 patients experienced intraoperative or perioperative complications. Hooks placed in connective tissue around the common carotid artery and jugular vein raised the vagus nerve by elevating the carotid sheath. A single surgeon was able to perform all cervical manipulations under a surgical microscope. The average operation time in this series of 21 patients was 137 minutes. The use of hooks attached to both sides of a rubber band rendered VNS implantation safer by lifting the vagus nerve and standardizing the procedure. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Evaluation in vitro of the tensile strength of crimpable hooks used for stabilization in orthognathic surgery.

    PubMed

    Andrade Gomes, Nascimento Leonard Euller; Melo, Pithon Matheus; Lacerda, Santos Rogério; D'Albuquerque, Medeiros Paulo Jose

    2012-03-01

    The aim of this study was to evaluate the tensile strength of crimpable hooks used for arch stabilization in orthognatic surgery. Ninety stainless steel wire (0.019" × 0.026") segments, each measuring 6 cm long, were used and attached to crimpable hooks of different commercial brands. Six groups were formed (n = 10) denominated as follows: control, in which the wire segments were perpendicularly welded by spot welding machine; and the hooks groups M (Morelli), MS (Morelli with weld), TP (TP Ortho), TPS (TP with weld), TPTg (TP-tungsten), TPTgS (TP-tungsten with weld), AO (American Orthodontics), and AOS (American Orthodontics with weld). The test specimen topography was evaluated by scanning electron microscopy before and after the tensile strength tests. After obtaining the results, the analysis of variance and Kruskal-Wallis multiple-comparison tests were applied. Compared with the control group, the AOS ball hooks and those from TPS required a greater amount of force to be displaced along the rectangular arch. The hooks in group M were significantly easier to displace, followed by those from AO. The best ball hooks for clinical application are those from AOS and TPS. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Prevalence of Ingested Fish Hooks in Freshwater Turtles from Five Rivers in the Southeastern United States

    PubMed Central

    Steen, David A.; Hopkins, Brittney C.; Van Dyke, James U.; Hopkins, William A.

    2014-01-01

    Freshwater turtles may ingest baited fish hooks because many are opportunistic scavengers. Although the ingestion of fish hooks is known to be a source of mortality in multiple vertebrate groups, the prevalence of hook ingestion by freshwater turtles has not been well studied. We trapped turtles from five rivers in the southeastern United States and used radiographs to examine over 600 individuals of four species. Depending on the species, sex, and age class, 0–33% of turtles contained ingested fish hooks. For some species, larger turtles were more likely to contain a fish hook than smaller individuals. Freshwater turtle demography suggests that even small increases in adult mortality may lead to population declines. If our study areas are representative of other aquatic systems that receive fishing pressure, this work likely identifies a potential conflict between a widespread, common recreational activity (i.e., fishing) and an imperiled taxonomic group. PMID:24621919

  4. Casual hook up sex during the first year of college: Prospective associations with attitudes about sex and love relationships.

    PubMed

    Katz, Jennifer; Schneider, Monica E

    2013-11-01

    This study examined bidirectional relationships among emerging adults' involvement in casual hook up sex and attitudes about sex and love relationships. At the start and end of their first year in college, undergraduates (N = 163) responded to measures of sexual behavior, sexual attitudes, and attitudes about love relationships. In cross-sectional analyses, attitudes about sex and love both were associated with involvement in casual hook up sex. In prospective analyses, initial attitudes about sexual instrumentality uniquely predicted involvement in later hook up sex, even after controlling for past hook up sex. Furthermore, involvement in hook up sex during the first year of college predicted greater sexual permissiveness and comfort with casual genital contact, even after controlling for initial sexual attitudes and hook up behaviors. None of the associations between attitudes and behavior were qualified by gender. Experiences of causal hook up sex appear to have implications primarily for emerging adults' attitudes about sexual interactions rather than their attitudes about love relationships.

  5. Evaluation of Two Miniplate Systems and Figure-of-eight Bandages for Stabilization of Experimentally Induced Ulnar and Radial Fractures in Pigeons ( Columba livia ).

    PubMed

    Bennert, Beatrice M; Kircher, Patrick R; Gutbrod, Andreas; Riechert, Juliane; Hatt, Jean-Michel

    2016-06-01

    Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

  6. Fish hook injury: removal by ''push through and cut off'' technique: a case report and brief literature review.

    PubMed

    Ahmad Khan, Hayat; Kamal, Younis; Lone, Ansar Ul Haq

    2014-04-01

    Fishing is a leisure activity for some people around the world. Accidently the fish hook can get hooked in the hand. If the hook is barbed, removal becomes difficult. We report a case of such a injury in the hand and discuss the technique for its removal with a brief review of the literature. A thirty-two year old male accidently suffered a fishhook injury to his hand. He came to the orthopaedic ward two hours after the incident with pain; the fish hook was hanging from the hand. Unsuccessful attempts to remove it were made by his relatives. A push-through and cut-off technique was used for removal of barbed hook. Barbed hooks are to be removed atraumatically with controlled incision over properly anaesthetised skin. Proper wound management and prophylactic antibiotics suitable for treatment of Aeromonas species should be initiated to prevent complications.

  7. Abnormally low hCG in a complete hydatidiform molar pregnancy: The hook effect.

    PubMed

    Nodler, James L; Kim, Kenneth H; Alvarez, Ronald D

    2011-01-01

    ► The hook effect occurs with extremely high levels of hCG, saturating detection antibodies, leading to falsely low laboratory results. ► In the literature, descriptions of the hook effect are rare in cases of gestational trophoblastic diseases. ► If unrecognized, this can lead to delayed therapy or mismanagement of care.

  8. Morphological and histochemical demonstration of hooks in the rostellar region of Cysticercus bovis.

    PubMed

    Zdárská, Z

    1976-01-01

    Hooklets and early developmental stages of hooks were discovered in the tegument among the microtriches in the rostellar region of 83- and 108-day-old Cysticercus bovis. The cortical layer of hooks consists of proteins with tyrosine and SS groups. The rostellar sac and bulb are distinctly developed in the parenchyma of the rostellar region.

  9. On the reliability of hook echoes as tornado indicators

    NASA Technical Reports Server (NTRS)

    Forbes, G. S.

    1981-01-01

    A study of radar echoes associated with the tornadoes of the 3 April 1974 outbreak was performed to evaluate the usefulness of echo shape as an indicator of tornadic thunderstorms. The hook shape was usually successful in characterizing an echo as tornadic, with a false alarm rate of 16%. Because hook echoes were relatively rare, however, a less restrictive shape called distinctive was more successful at detecting tornadic thunderstorms, identifying 65% of the tornadic echoes. An echo had a distinctive shape if it possessed a marked appendage on its right rear flank or was in the shape of a spiral, comma or line echo wave pattern (LEWP). Characteristics of the distinctive echo are given.

  10. Grayia spinosa (Hook.) Moq.: spiny hopsage

    Treesearch

    Nancy L. Shaw; Marshall R. Haferkamp; Emerenciana G. Hurd

    2008-01-01

    The genus Grayia Hook. & Arn., named for the American botanist Asa Gray, contains a single species - spiny hopsage (table 1). Plants are erect to rounded, summer-deciduous shrubs 0.3 to 1.2 (1.5) m tall. Branches are divergent and thorn-tipped, with whitish gray to brownish bark that exfoliates in long strips. Leaves are gray-green, alternate, entire, and fleshy,...

  11. Ultrastructure and chemical composition of the proboscis hooks of Acanthocephalus lucii (Müller, 1776) (Acanthocephala: Palaeacanthocephala) using X-ray elemental analysis.

    PubMed

    Brázová, Tímea; Poddubnaya, Larisa G; Miss, Noemí Ramírez; Hanzelová, Vladimíra

    2014-12-01

    The ultrastructure and chemical composition of the proboscis hooks and surrounding tegument of Acanthocephalus lucii (Müller, 1776), a parasite of European perch, Perca fluviatilis Linnaeus, were examined using scanning (SEM) and transmission (TEM) electron microscopy and X-ray microanalysis (EDXA). The blade of middle hooks consists of three layers: an outer homogeneous layer, an inner heterogeneous layer and a central core. TEM observation revealed the presence of hollow tubes, which spaced the central core; fibrous inner hook layer surrounded by an electron-dense margin and the basal tegumental layer filled with electron-dense bodies and outer layer. We found for the first time that the so-called 'epidermal covering' surrounding of the exposed hook blade (outer hook layer) is a modified striped portion of the tegumental layer and there are no special contact sites between these two morphologically different structures, i.e. striped layer of the syncytial tegument and following proper outer hook layer, which is a homogeneous, moderately electron-dense layer of -0.3 μm in thickness. The hook root is embedded into subtegumental fibrous layer. X-ray microanalysis of both the surface and internal parts of A. lucii hooks demonstrated the presence of calcium, magnesium, phosphorus and sulphur. The highest concentration of sulphur was recorded at the tip of hooks, whereas the middle part of the hooks was most rich in calcium, phosphorus and magnesium. The proximal part of the hooks contained lower concentrations of sulphur, calcium and phosphorus. In the proboscis tegument, only two elements, calcium and silicon, were found. The differences observed in the chemical composition of the hook 'epidermal covering' and the proboscis tegument support our ultrastructural findings that the hook tegumental covering is a modified structure compared with that of the general proboscis tegument.

  12. Comparison of concentric needle versus hooked-wire electrodes in the canine larynx.

    PubMed

    Jaffe, D M; Solomon, N P; Robinson, R A; Hoffman, H T; Luschei, E S

    1998-05-01

    The use of a specific electrode type in laryngeal electromyography has not been standardized. Laryngeal electromyography is usually performed with hooked-wire electrodes or concentric needle electrodes. Hooked-wire electrodes have the advantage of allowing laryngeal movement with ease and comfort, whereas the concentric needle electrodes have benefits from a technical aspect and may be advanced, withdrawn, or redirected during attempts to appropriately place the electrode. This study examines whether hooked-wire electrodes permit more stable recordings than standard concentric needle electrodes at rest and after large-scale movements of the larynx and surrounding structures. A histologic comparison of tissue injury resulting from placement and removal of the two electrode types is also made by evaluation of the vocal folds. Electrodes were percutaneously placed into the thyroarytenoid muscles of 10 adult canines. Amplitude of electromyographic activity was measured and compared during vagal stimulation before and after large-scale laryngeal movements. Signal consistency over time was examined. Animals were killed and vocal fold injury was graded and compared histologically. Waveform morphology did not consistently differ between electrode types. The variability of electromyographic amplitude was greater for the hooked-wire electrode (p < 0.05), whereas the mean amplitude measures before and after large-scale laryngeal movements did not differ (p > 0.05). Inflammatory responses and hematoma formation were also similar. Waveform morphology of electromyographic signals registered from both electrode types show similar complex action potentials. There is no difference between the hooked-wire electrode and the concentric needle electrode in terms of electrode stability or vocal fold injury in the thyroarytenoid muscle after large-scale laryngeal movements.

  13. 49 CFR 393.134 - What are the rules for securing roll-on/roll-off or hook lift containers?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... or hook lift containers? 393.134 Section 393.134 Transportation Other Regulations Relating to... for securing roll-on/roll-off or hook lift containers? (a) Applicability. The rules in this section apply to the transportation of roll-on/roll-off or hook lift containers. (b) Securement of a roll-on...

  14. 49 CFR 393.134 - What are the rules for securing roll-on/roll-off or hook lift containers?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... or hook lift containers? 393.134 Section 393.134 Transportation Other Regulations Relating to... for securing roll-on/roll-off or hook lift containers? (a) Applicability. The rules in this section apply to the transportation of roll-on/roll-off or hook lift containers. (b) Securement of a roll-on...

  15. Physiological response to hooking stress in hatchery and wild rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Wydoski, R.S.; Wedemeyer, G.A.; Nelson, N. C.

    1976-01-01

    This study evaluated the physiological response of rainbow trout to hooking stress after being played under standardized conditions (0–5 min) and estimated the time needed for recovery (to 72 h). Plasma osmolality and chloride measurements were used to evaluate osmoregulatory disturbances and gill ion-exchange function, and plasma glucose was used as an index of the generalized nonspecific physiological stress response. Hooking stress caused more severe blood chemistry differences in hatchery fish than in wild trout. Also, hooking stress imposed a greater stress on larger than on smaller hatchery rainbow trout. Higher water temperatures aggravated the delayed hyperglycemia and hyperchloremia in both hatchery and wild trout but only about 3 days were needed for recovery at 4, 10, or 20 C.

  16. The remarkable vision of Robert Hooke (1635-1703): first observer of the microbial world.

    PubMed

    Gest, Howard

    2005-01-01

    Robert Hooke played important roles in the early development of the Royal Society of London. As Curator of Experiments of the Society, he became a pioneering microscopist, prolific inventor, astronomer, geologist, architect, and an effective surveyor of the City of London following the Great Fire of 1666. Hooke's Micrographia (1665) revealed the microscopic structures of numerous biological and inorganic objects and became an important source of information for later studies. Aside from the body of detailed observations reported and depicted in Micrographia, the Preface is in itself an extraordinary document that exhibits Hooke's fertile mind, philosophical insights, and rare ability to look into the future.

  17. Jurassic onychites (arm hooks) from squid-like cephalopods from the Wessex Basin, southern England

    NASA Astrophysics Data System (ADS)

    Hart, Malcolm; Hughes, Zoe; Page, Kevin; Price, Gregory; Smart, Christopher

    2017-04-01

    Modern coleoid (squid-like) cephalopods have arms that carry arrays of both suckers and hardened, organic hooks. Fossil arm hooks have been known since the description of Sternberg in 1823, although he identified them as algal remains. During the twentieth century there have been a number of descriptions of hooks (Kulicki & Szaniawski, 1972; Clarke & Engeser, 1988). Kulicki & Szaniawski (1972) gave these 'morphotypes' names using a binomial classification though, with many lacking defined (and figured) holotypes and, in some cases, only one recorded specimen, some of their designations should be regarded as invalid. Some of their morphotypes have, however, been reported widely, from DSDP sites on the Falkland Plateau as well as New Zealand, Germany, Svalbard, Poland and the United Kingdom. Exceptional soft-bodied preservation of species such as Belemnotheutis antiquus (Pearce, 1847) from the Callovian-Oxfordian of Wiltshire (UK) and Clarkeiteuthis montefiore (Buckman, 1880) from the Sinemurian of Dorset (UK) has allowed the identification of the host animal of some morphotypes, though the majority remain un-attributable. In the Christian Malford lagerstätte (Upper Callovian) of Wiltshire large numbers of hooks (including forms described as Acanthuncus, Arites, Deinuncus, Falcuncus, Longuncus and Paraglycerites) are found associated with an abundance of statoliths (cephalopod 'ear bones') and macrofossil evidence of both belemnites and teuthids, some of which includes exceptional soft-bodied preservation (Wilby et al., 2004; Hart et al., 2016). Many of the hook types cannot, at present be assigned to known taxa of coleoid. In Belemnotheutis antiquus there appears to be one form of simple, slightly curved hook and their shape appears to remain constant throughout the Callovian -Kimmeridgian interval. In the Lias Group, hooks of Clarkeiteuthis are very different, with inflated, often bi-lobate bases and each arm often characterised by the presence of different shapes

  18. The influence of hook type, angler experience, and fish size on injury rates and the duration of capture in an Alaskan catch-and-release rainbow trout fishery

    USGS Publications Warehouse

    Meka, Julie M.

    2004-01-01

    Owing to concerns about the high incidence of past hooking injuries in Alagnak River rainbow trout Oncorhynchus mykiss, fish were captured with spin- and fly-fishing gear with barbed and barbless circle and "J" hooks to determine gear types contributing to injury. Landing and hook removal times were measured for a portion of fish captured, and the anatomical hooking location, hooking scar locations, bleeding intensity, angler experience, and fish size were recorded for all captured fish. Approximately 62% of fish captured experienced at least one new hooking injury, and 29% of fish had at least one past hooking injury. Small fish sustained higher new injury and bleeding rates, but large fish had higher past injury rates. Injury rates were higher for barbed J hooks, barbed J hooks took longer to remove, and fish caught by spin-fishing were injured more frequently than fish caught by fly-fishing. Fewer fly-fishing-caught fish were injured using circle hooks, and circle hooks tended to hook fish in only one location, generally in the jaw. Barbed J hooks were more efficient at landing fish, and J hooks were more efficient at landing fish than circle hooks. Novice anglers injured proportionally more fish than experienced anglers, primarily during hook removal. Landing time was positively correlated with fish size, and experienced anglers took longer to land fish than novices because they captured larger fish. These results suggest that a reduction in hooking injuries may be achieved by using circle hooks as an alternative to J hooks and barbless J hooks to reduce injury and handling time, yet catch efficiency for both methods would be reduced. Although fish captured with barbless J hooks and circle hooks had fewer injuries, it is important to note that each hook type also caused significant injury, and angler education is recommended to promote proper hook removal techniques.

  19. 78 FR 23864 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... Catcher/Processors Using Hook-and-line Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY.../processors (C/Ps) using hook-and-line gear in the Western Regulatory Area of the Gulf of Alaska (GOA). This... catch apportioned to C/Ps using hook-and-line gear in the Western Regulatory Area of the GOA. DATES...

  20. 77 FR 11776 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    .../Processors Using Hook-and-Line Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National... (C/Ps) using hook-and-line gear in the Central Regulatory Area of the Gulf of Alaska (GOA). This... catch apportioned to C/Ps using hook-and-line gear in the Central Regulatory Area of the GOA. DATES...

  1. Anharmonic Vibrations of an "Ideal" Hooke's Law Oscillator

    ERIC Educational Resources Information Center

    Thomchick, John; McKelvey, J. P.

    1978-01-01

    Presents a model describing the vibrations of a mass connected to fixed supports by "ideal" Hooke's law springs which may serve as a starting point in the study of the properties of irons in a crystal undergoing soft mode activated transition. (SL)

  2. A double standard for "Hooking Up": How far have we come toward gender equality?

    PubMed

    Allison, Rachel; Risman, Barbara J

    2013-09-01

    While sexual attitudes have liberalized in the past half century, research is mixed as to whether attitudes have become less gendered over time. Recent studies on college students' sexual and romantic relationships suggest that a sexual double standard continues to organize sexuality on many campuses. Data from the Online College Social Life Survey shed light on students' evaluation of casual sex, or "hooking up." In addition to exploring gendered attitudinal patterns, we use gender structure theory to explore how individual characteristics and normative expectations of campus group affiliations shape attitudes. While three quarters of students do not hold different standards for men and women's hooking up, attitudes are more conservative than liberal, with almost half of students losing respect for men and women who hook up "a lot." However, men are more likely to hold a traditional double standard, while women are more likely to espouse egalitarian conservative attitudes. Individual characteristics, including age, religion, race, social class and sexual orientation are frequently related to sexual attitudes, as are number of hook ups, fraternity/sorority affiliation and varsity athletic participation. Published by Elsevier Inc.

  3. The influence of pornography on sexual scripts and hooking up among emerging adults in college.

    PubMed

    Braithwaite, Scott R; Coulson, Gwen; Keddington, Krista; Fincham, Frank D

    2015-01-01

    The explosive growth in access to the Internet has led to a commensurate increase in the availability, anonymity, and affordability of pornography. An emerging body of research has shown associations between pornography and certain behaviors and attitudes; yet, how pornography actually influences these outcomes has not been documented. In two studies (Study 1 N = 969; Study 2 N = 992) we examined the hypothesis that pornography influences potentially risky sexual behavior (hooking up) among emerging adults via sexual scripts. Our results demonstrate that more frequent viewing of pornography is associated with a higher incidence of hooking up and a higher number of unique hook up partners. We replicated these effects both cross-sectionally and longitudinally while accounting for the stability of hook ups over the course of an academic semester. We also demonstrated that more frequent viewing of pornography is associated with having had more previous sexual partners of all types, more one occasion sexual partners ("one night stands"), and plans to have a higher number of sexual partners in the future. Finally, we provided evidence that more permissive sexual scripts mediated the association between more frequent pornography viewing and hooking up. We discuss these findings with an eye toward mitigating potential personal and public health risks among emerging adults.

  4. Automation Hooks Architecture for Flexible Test Orchestration - Concept Development and Validation

    NASA Technical Reports Server (NTRS)

    Lansdowne, C. A.; Maclean, John R.; Winton, Chris; McCartney, Pat

    2011-01-01

    The Automation Hooks Architecture Trade Study for Flexible Test Orchestration sought a standardized data-driven alternative to conventional automated test programming interfaces. The study recommended composing the interface using multicast DNS (mDNS/SD) service discovery, Representational State Transfer (Restful) Web Services, and Automatic Test Markup Language (ATML). We describe additional efforts to rapidly mature the Automation Hooks Architecture candidate interface definition by validating it in a broad spectrum of applications. These activities have allowed us to further refine our concepts and provide observations directed toward objectives of economy, scalability, versatility, performance, severability, maintainability, scriptability and others.

  5. Use of the S-hook for Pelvic Fixation in Rib-Based Treatment of Early-Onset Scoliosis: A Multicenter Study.

    PubMed

    Ramirez, Norman; Flynn, John M; Smith, John T; Vitale, Michael; Sturm, Peter F; DʼAmato, Charles; Samdani, Amer; Machiavelli, Raul; El-Hawary, Ron

    2015-06-01

    Retrospective review. The purpose of this study was to evaluate how several preoperative variables affect the outcome using the rib-to-pelvis S-hook constructs of a rib-based distraction implant (Vertical Expandable Prosthetic Titanium Rib). Rib-to-pelvis fixation with S-hooks is one of the options for distal anchoring of rib-based distraction growing rod construct to control early-onset spinal deformity. Since the initial report, the indications of pelvic fixation with S-hooks have been extended and modified. This is an institutional review board-approved retrospective study of patients who underwent rib-based growing rod system surgery-rib-to-pelvis construct with Dunn-McCarthy S-hook. Data evaluation included history, physical examination, preoperative and postoperative radiographs, surgical variables, and complications. Sixty-five patients were evaluated; 38 were male and 27 were female. Mean age at initial procedure was 71 months. The mean follow-up was 46 months. There was a statistically significant improvement of the immediate postoperative Cobb angle and the last follow-up Cobb angle (P < 0.0001). Fifty percent of the patients (32/65) had S-hook-related complications. The most common complication was sliding of the S-hook out of the iliac crest, followed by infection, neuropathic pain, distal migration of more than 2 cm, fracture of the hook, and bursitis. The complications were related to the preoperative ambulatory status, the use of end-to-end rod connectors, surgical time, and not positioning the hook over the central one-third of the iliac crest at the initial implantation. The use of the S-hook as a pelvic attachment of the rib-based system is indicated in nonambulatory patients with progressive, early-onset scoliosis curve with a lack of adequate anchor at the lumbar spine. Several technical factors should be considered to reduce the complication rate. 3.

  6. Astronaut James Newman with latch hook for tether device

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Astronaut James H. Newman, mission specialist, shows off a latch hook for a tether device used during the STS-51 extravehicular activity (EVA) on September 16, 1993. Newman, on Discovery's middeck, appears surrounded by sleep restraints.

  7. Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

    PubMed

    Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel

    2016-01-16

    Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.

  8. Are we sinking Sandy Hook? Possible impacts of groundwater extraction to sea-level change

    NASA Astrophysics Data System (ADS)

    Johnson, C. S.; Fan, Y.; Miller, K. G.; Browning, J. V.

    2017-12-01

    The tide gauge at Sandy Hook, NJ, a spit of sand extending 8 km into Raritan Bay of New York and New Jersey, recorded a 20th century rate of relative sea-level (RSL) rise of 4.0±0.5 mm/yr, significantly higher than the 1.4±0.2 mm/yr rate of global mean sea-level rise for the twentieth century. The Battery, NY tide gauge, located atop crystalline bedrock 26 km to the northwest, recorded a 20th century rate of RSL rise of 3.0±0.3 mm/yr and reflects the regional rate of RSL rise. After global and regional effects are removed from the rate of RSL rise at Sandy Hook, the remaining 0.9±0.5 mm/yr is due to local effects, autocompaction and groundwater extraction induced compaction, within the unconsolidated Cretaceous to recent sediments underlying Sandy Hook. Our previous work showed that 0.13 mm/yr (90% CI 0.01-0.34 mm/yr) is due to autocompaction of young (≤13,350 cal yrs BP), highly compressible, Quaternary sediments underlying Sandy Hook. The remaining 0.8 mm/yr (90% CI 0.3-1.2 mm/yr) is hypothesized to be due to regional and local groundwater extraction. Previous studies have shown that Sandy Hook is within the cone of depression for Monmouth County, NJ. Historical records indicate that pumping for Ft. Hancock, a military installation on Sandy Hook, depleted some shallow aquifers as early as 1905. Visual MODFLOW was used to model the northern portion of the New Jersey coastal plain. Well logs from the northern New Jersey coastal plain were compiled and interpreted to refine subsurface geometries and build the model grid. Well permits provided modern locations and rates of groundwater extraction. 1,794 observation wells were used to calibrate the model. We present model results simulating the change in regional and local groundwater flow and hydraulic pressures from pre-development ( 1880) to present. The pressure changes were then used to calculate the potential changes in thickness of each of the stratigraphic units underneath Sandy Hook between 1880 and

  9. The Hooked Galaxy

    NASA Astrophysics Data System (ADS)

    2006-06-01

    Life is not easy, even for galaxies. Some indeed get so close to their neighbours that they get rather distorted. But such encounters between galaxies have another effect: they spawn new generations of stars, some of which explode. ESO's VLT has obtained a unique vista of a pair of entangled galaxies, in which a star exploded. Because of the importance of exploding stars, and particularly of supernovae of Type Ia [1], for cosmological studies (e.g. relating to claims of an accelerated cosmic expansion and the existence of a new, unknown, constituent of the universe - the so called 'Dark Energy'), they are a preferred target of study for astronomers. Thus, on several occasions, they pointed ESO's Very Large Telescope (VLT) towards a region of the sky that portrays a trio of amazing galaxies. MCG-01-39-003 (bottom right) is a peculiar spiral galaxy, with a telephone number name, that presents a hook at one side, most probably due to the interaction with its neighbour, the spiral galaxy NGC 5917 (upper right). In fact, further enhancement of the image reveals that matter is pulled off MCG-01-39-003 by NGC 5917. Both these galaxies are located at similar distances, about 87 million light-years away, towards the constellation of Libra (The Balance). ESO PR Photo 22/06 ESO PR Photo 22/06 The Hooked Galaxy and its Companion NGC 5917 (also known as Arp 254 and MCG-01-39-002) is about 750 times fainter than can be seen by the unaided eye and is about 40,000 light-years across. It was discovered in 1835 by William Herschel, who strangely enough, seems to have missed its hooked companion, only 2.5 times fainter. As seen at the bottom left of this exceptional VLT image, a still fainter and nameless, but intricately beautiful, barred spiral galaxy looks from a distance the entangled pair, while many 'island universes' perform a cosmic dance in the background. But this is not the reason why astronomers look at this region. Last year, a star exploded in the vicinity of the hook

  10. Growth plate cartilage shows different strain patterns in response to static versus dynamic mechanical modulation.

    PubMed

    Kaviani, Rosa; Londono, Irene; Parent, Stefan; Moldovan, Florina; Villemure, Isabelle

    2016-08-01

    Longitudinal growth of long bones and vertebrae occurs in growth plate cartilage. This process is partly regulated by mechanical forces, which are one of the underlying reasons for progression of growth deformities such as idiopathic adolescent scoliosis and early-onset scoliosis. This concept of mechanical modulation of bone growth is also exploited in the development of fusionless treatments of these deformities. However, the optimal loading condition for the mechanical modulation of growth plate remains to be identified. The objective of this study was to evaluate the effects of in vitro static versus dynamic modulation and of dynamic loading parameters, such as frequency and amplitude, on the mechanical responses and histomorphology of growth plate explants. Growth plate explants from distal ulnae of 4-week-old swines were extracted and randomly distributed among six experimental groups: baseline ([Formula: see text]), control ([Formula: see text]), static ([Formula: see text]) and dynamic ([Formula: see text]). For static and dynamic groups, mechanical modulation was performed in vitro using an Indexed CartiGen bioreactor. A stress relaxation test combined with confocal microscopy and digital image correlation was used to characterize the mechanical responses of each explant in terms of peak stress, equilibrium stress, equilibrium modulus of elasticity and strain pattern. Histomorphometrical measurements were performed on toluidine blue tissue sections using a semi-automatic custom-developed MATLAB toolbox. Results suggest that compared to dynamic modulation, static modulation changes the strain pattern of the tissue and thus is more detrimental for tissue biomechanics, while the histomorphological parameters are not affected by mechanical modulation. Also, under dynamic modulation, changing the frequency or amplitude does not affect the biomechanical response of the tissue. Results of this study will be useful in finding optimal and non-damaging parameters

  11. Use of brachial plexus blockade and medetomidine-ketamine-isoflurane anaesthesia for repair of radio-ulna fracture in an adult cheetah (Acinonyx jubatus).

    PubMed

    Kimeli, Peter; Mogoa, Eddy M; Mwangi, Willy E; Kipyegon, Ambrose N; Kirui, Gilbert; Muasya, Daniel W; Mande, John D; Kariuki, Edward; Mijele, Dominic

    2014-10-10

    Regional anaesthetic techniques have been used in combination with systemic analgesics during small animal surgery to provide multimodal analgesia. Brachial plexus nerves block using local anaesthetics provides analgesia of the thoracic limb through desensitization of the nerves that provide sensory and motor innervation. This has been shown to reduce intra-operative anesthetic requirements and provide postoperative pain relief. Decreasing the doses of general anaesthetics allows more stable cardiopulmonary function during anaesthesia and the development of less side effects. The present case reports a successful use of brachial plexus blockade to supplement medetomidine-ketamine-isoflurane anaesthesia for repair of radio-ulna fracture in an adult cheetah (acinonyx jubatus). An adult male Cheetah weighing about 65 kg was presented with a history of leg carrying lameness of the left forelimb sustained following a car accident a week earlier. Clinical examination under general anaesthesia revealed slight dehydration and a swelling with a wound on the caudo-medial aspect of the left radio-ulna region. Crepitation was present on manipulation and radiography confirmed a complete transverse radio-ulna fracture of the left forelimb, which required open reduction and internal fixation. Brachial plexus blockade using lignocaine hydrochloride was used to supplement medetomidine-ketamine-isoflurane anaesthesia for the surgical procedure. Isoflurane anaesthesia was maintained at 0.5 - 2.0% throughout the surgical procedure, which was uneventful. Temperature and cardio-pulmonary parameters remained stable intra-operatively. Limb paralysis extended for 5 hours post-operatively, suggesting prolonged anaesthesia. To the researchers' knowledge, this is the first reported case of the use of brachial plexus blockade to supplement general anaesthesia to facilitate forelimb surgery in an adult cheetah. The use of brachial plexus block with a light plane of general anaesthesia proved to

  12. Hook tool manufacture in New Caledonian crows: behavioural variation and the influence of raw materials.

    PubMed

    Klump, Barbara C; Sugasawa, Shoko; St Clair, James J H; Rutz, Christian

    2015-11-18

    New Caledonian crows use a range of foraging tools, and are the only non-human species known to craft hooks. Based on a small number of observations, their manufacture of hooked stick tools has previously been described as a complex, multi-stage process. Tool behaviour is shaped by genetic predispositions, individual and social learning, and/or ecological influences, but disentangling the relative contributions of these factors remains a major research challenge. The properties of raw materials are an obvious, but largely overlooked, source of variation in tool-manufacture behaviour. We conducted experiments with wild-caught New Caledonian crows, to assess variation in their hooked stick tool making, and to investigate how raw-material properties affect the manufacture process. In Experiment 1, we showed that New Caledonian crows' manufacture of hooked stick tools can be much more variable than previously thought (85 tools by 18 subjects), and can involve two newly-discovered behaviours: 'pulling' for detaching stems and bending of the tool shaft. Crows' tool manufactures varied significantly: in the number of different action types employed; in the time spent processing the hook and bending the tool shaft; and in the structure of processing sequences. In Experiment 2, we examined the interaction of crows with raw materials of different properties, using a novel paradigm that enabled us to determine subjects' rank-ordered preferences (42 tools by 7 subjects). Plant properties influenced: the order in which crows selected stems; whether a hooked tool was manufactured; the time required to release a basic tool; and, possibly, the release technique, the number of behavioural actions, and aspects of processing behaviour. Results from Experiment 2 suggested that at least part of the natural behavioural variation observed in Experiment 1 is due to the effect of raw-material properties. Our discovery of novel manufacture behaviours indicates a plausible scenario for the

  13. Extremely high myoglobin plasma concentrations producing hook effect in a critically ill patient.

    PubMed

    Kurt-Mangold, Michelle; Drees, Denny; Krasowski, Matthew D

    2012-12-24

    A 21-year old female suffered a cardiac arrest after a one week history of viral illness later shown to be caused by influenza B. The patient required extended cardiopulmonary resuscitation and had further complications including compartment syndrome. Plasma myoglobin concentration was measured using the Roche Diagnostics electrochemiluminescent myoglobin assay. The myoglobin concentration was 205,590 μg/l in an undiluted specimen, consistent with severe rhabdomyolysis. Subsequent myoglobin concentrations measured two days later showed dramatic decreases to approximately 1000 μg/l, raising suspicion of a hook effect. Dilution and re-analysis of the specimens revealed that the actual myoglobin concentrations were >395,000 μg/l, with one specimen possessing an estimated myoglobin concentration of >600,000 μg/l. Interestingly, three specimens from this patient did not show evidence of hook effect, with undiluted specimens producing myoglobin concentrations as high as 284,000 μg/l. Retrospective analysis of myoglobin results over an 8-year period did not reveal other cases with suspicion of hook effect. The case patient had the highest myoglobin concentrations out of 7301 specimens. This case illustrates that while the Roche myoglobin assay has a very wide dynamic range, hook effect can occur with extremely high concentrations of plasma myoglobin. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Comparison of the intrusion effects on the maxillary incisors between implant anchorage and J-hook headgear.

    PubMed

    Deguchi, Toru; Murakami, Takashi; Kuroda, Shingo; Yabuuchi, Toshinori; Kamioka, Hiroshi; Takano-Yamamoto, Teruko

    2008-05-01

    Recently, miniscrews have been used to provide anchorage during orthodontic treatment, especially for incisor intrusion. Miniscrews during incisor intrusion are commonly used in implant orthodontics. Traditionally, effective incisor intrusion has been accomplished with J-hook headgear. In this study, we compared the effect of incisor intrusion, force vector, and amount of root resorption between implant orthodontics and J-hook headgear. Lateral cephalometric radiographs from 8 patients in the implant group and 10 patients in the J-hook headgear group were analyzed for incisor retraction. The estimated force vector was analyzed in the horizontal and vertical directions in both groups. Root resorption was also measured on periapical radiographs. In the implant group, significant reductions in overjet, overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip were observed after intrusion of the incisors. In the J-hook headgear group, significant reductions in overjet, overbite, maxillary incisor to upper lip, and maxillary incisor to SN plane were observed after intrusion of the incisors. There were significantly greater reductions in overbite, maxillary incisor to palatal plane, and maxillary incisor to upper lip in the implant group than in the J-hook headgear group. Estimated force analysis resulted in significantly more force in the vertical direction and less in the horizontal direction in the implant group. Furthermore, significantly less root resorption was observed in the implant group compared with the J-hook headgear group. The maxillary incisors were effectively intruded by using miniscrews as orthodontic anchorage without patient cooperation. The amount of root resorption was not affected by activating the ligature wire from the miniscrew during incisor intrusion.

  15. Columbia Smelting & Refining Works Red Hook, Brooklyn, New York

    EPA Pesticide Factsheets

    The site is the former location of a secondary lead smelter called Columbia Smelting and Refining Works (Columbia), and the extent of lead-contaminated soil from the smelter, in the mixed-use neighborhood of Red Hook in Brooklyn, New York. The footprint of

  16. Mitigating the Hook Effect in Lateral Flow Sandwich Immunoassays Using Real-Time Reaction Kinetics.

    PubMed

    Rey, Elizabeth G; O'Dell, Dakota; Mehta, Saurabh; Erickson, David

    2017-05-02

    The quantification of analyte concentrations using lateral flow assays is a low-cost and user-friendly alternative to traditional lab-based assays. However, sandwich-type immunoassays are often limited by the high-dose hook effect, which causes falsely low results when analytes are present at very high concentrations. In this paper, we present a reaction kinetics-based technique that solves this problem, significantly increasing the dynamic range of these devices. With the use of a traditional sandwich lateral flow immunoassay, a portable imaging device, and a mobile interface, we demonstrate the technique by quantifying C-reactive protein concentrations in human serum over a large portion of the physiological range. The technique could be applied to any hook effect-limited sandwich lateral flow assay and has a high level of accuracy even in the hook effect range.

  17. Astronaut James Newman with latch hook for tether device

    NASA Image and Video Library

    1993-09-19

    STS051-26-002 (12-22 Sept 1993) --- Astronaut James H. Newman, mission specialist, shows off a latch hook for a tether device used during the STS-51 extravehicular activity (EVA) on September 16, 1993. Newman, on Discovery's middeck, appears surrounded by sleep restraints.

  18. Plate with decentralised velocity feedback loops: Power absorption and kinetic energy considerations

    NASA Astrophysics Data System (ADS)

    Gardonio, P.; Miani, S.; Blanchini, F.; Casagrande, D.; Elliott, S. J.

    2012-04-01

    This paper is focused on the vibration effects produced by an array of decentralised velocity feedback loops that are evenly distributed over a rectangular thin plate to minimise its flexural response. The velocity feedback loops are formed by collocated ideal velocity sensor and point force actuator pairs, which are unconditionally stable and produce 'sky-hook' damping on the plate. The study compares how the overall flexural vibration of the plate and the local absorption of vibration power by the feedback loops vary with the control gains. The analysis is carried out both considering a typical frequency-domain formulation based on kinetic energy and structural power physical quantities, which is normally used to study vibration and noise problems, and a time-domain formulation also based on kinetic energy and structural power, which is usually implemented to investigate control problems. The time-domain formulation shows to be much more computationally efficient and robust with reference to truncation errors. Thus it has been used to perform a parametric study to assess if, and under which conditions, the minimum of the kinetic energy and the maximum of the absorbed power cost functions match with reference to: (a) the number of feedback control loops, (b) the structural damping in the plate, (c) the mutual distance of a pair of control loops and (d) the mutual gains implemented in a pair of feedback loops.

  19. Meanest foundations and nobler superstructures: Hooke, Newton and the "compounding of the celestiall motions of the planets

    NASA Astrophysics Data System (ADS)

    Gal, Ofer

    This book is a historical-epistemological study of one the most consequential idea of early modern celestial mechanics: Robert Hooke's proposal to "compoun[d] the celestial motions of the planets of a direct motion by the tangent & an attractive motion towards a central body," a proposal which Isaac Newton adopted and realized in his Principia. Hooke's Programme was revolutionary both cosmologically and mathematically. It presented "the celestial motions," the proverbial symbol of stability and immutability, as a process of continuous change, and prescribed only parameters of rectilinear motions and rectilinear attractions for calculating their closed curved orbits. Yet the traces of Hooke's construction of his Programme for the heavens lead through his investigations in such earthly disciplines as microscopy, practical optics and horology, and the mathematical tools developed by Newton to accomplish it appear no less local and goal-oriented than Hooke's lenses and springs. This transgression of the boundaries between the theoretical, experimental and technological realms is reminiscent of Hooke's own free excursions in and out of the circles occupied by gentlemen-philosophers, university mathematicians, instrument makers, technicians and servants. It presents an opportunity to examine the social and epistemological distinctions, relations and hierarchies between those realms and their inhabitants, and compels a critical assessment of the philosophical categories they embody.

  20. School Safety in a Post-Sandy Hook World

    ERIC Educational Resources Information Center

    Trump, Kenneth S.

    2014-01-01

    In this report the author, who is a school safety expert, provides information about school safety in a post-Sandy Hook world. He presents the following: (1) Continuum of Threats and Responses; (2) The role social media plays; (3) Reliable Best Practices; (4) Policy and Funding--Climate and Context; (5) Policy and Funding--Things to Avoid; and (6)…

  1. The "hook effect" causing a negative pregnancy test in a patient with an advanced molar pregnancy.

    PubMed

    Winder, Abigail D; Mora, Adria Suarez; Berry, Emily; Lurain, John R

    2017-08-01

    •At high hCG levels in molar pregnancies, a "hook effect" can cause an artificially negative value.•Delay in diagnosis of a molar pregnancy due to the "hook effect" can lead to severe complications.•Suspicion of a molar pregnancy should be communicated so a diluted sample is used to quantify hCG.

  2. The discovery of microorganisms by Robert Hooke and Antoni Van Leeuwenhoek, fellows of the Royal Society.

    PubMed

    Gest, Howard

    2004-05-01

    The existence of microscopic organisms was discovered during the period 1665-83 by two Fellows of The Royal Society, Robert Hooke and Antoni van Leeuwenhoek. In Micrographia (1665), Hooke presented the first published depiction of a microganism, the microfungus Mucor. Later, Leeuwenhoek observed and described microscopic protozoa and bacteria. These important revelations were made possible by the ingenuity of Hooke and Leeuwenhoek in fabricating and using simple microscopes that magnified objects from about 25-fold to 250-fold. After a lapse of more than 150 years, microscopy became the backbone of our understanding of the roles of microbes in the causation of infectious diseases and the recycling of chemical elements in the biosphere.

  3. Rose Prickles and Asparagus Spines--Different Hook Structures as Attachment Devices in Climbing Plants.

    PubMed

    Gallenmüller, Friederike; Feus, Amélie; Fiedler, Kathrin; Speck, Thomas

    2015-01-01

    Functional morphology and biomechanical properties of hook structures functioning as attachment devices in the leaning climbers Rosa arvensis, Rosa arvensis 'Splendens', Asparagus falcatus and Asparagus setaceus are analysed in order to investigate the variability in closely related species as well as convergent developments of hook structure and properties in distant systematic lineages (monocots and dicots). Prickles and spines were characterised by their size, orientation and the maximum force measured at failure in mechanical tests performed with traction forces applied at different angles. In Rosa arvensis and Rosa arvensis 'Splendens' three types of prickles differing largely in geometrical and mechanical properties are identified (prickles of the wild species and two types of prickles in the cultivar). In prickles of Rosa arvensis no particular orientation of the prickle tip is found whereas in the cultivar Rosa arvensis 'Splendens' prickles gradually gain a downward-orientation due to differential growth in the first weeks of their development. Differences in mechanical properties and modes of failure are correlated to geometrical parameters. In Asparagus falcatus and Asparagus setaceus spines are composed of leaf tissue, stem tissue and tissue of the axillary bud. Between species spines differ in size, orientation, distribution along the stem, tissue contributions and mechanical properties. The prickles of Rosa arvensis and its cultivar and the spines of the studied Asparagus species have several traits in common: (1) a gradual change of cell size and cell wall thickness, with larger cells in the centre and smaller thick-walled cells at the periphery of the hooks, (2) occurrence of a diversity of shape and geometry within one individual, (3) failure of single hooks when submitted to moderate mechanical stresses (Fmax/basal area < 35 N/mm²) and (4) failure of the hooks without severe stem damage (at least in the tested wild species).

  4. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  5. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  6. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  7. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  8. 33 CFR 334.102 - Sandy Hook Bay, Naval Weapons Station EARLE, Piers and Terminal Channel, restricted area...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Sandy Hook Bay, Naval Weapons... DANGER ZONE AND RESTRICTED AREA REGULATIONS § 334.102 Sandy Hook Bay, Naval Weapons Station EARLE, Piers..., shall be enforced by the Commanding Officer, Naval Weapons Station Earle, and/or other persons or...

  9. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    PubMed

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.

  10. Gateway National Recreation Area - Sandy Hook Unit : parking management study

    DOT National Transportation Integrated Search

    2003-12-01

    This report describes the Parking Management System (PMS) concept for the Sandy Hook Traveler Information System (TIS). The PMS is an important component of the TIS because it ultimately will be used to determine the open / closed status of the park....

  11. Structural and genetic analysis of a mutant of Rhodobacter sphaeroides WS8 deficient in hook length control.

    PubMed Central

    González-Pedrajo, B; Ballado, T; Campos, A; Sockett, R E; Camarena, L; Dreyfus, G

    1997-01-01

    Motility in the photosynthetic bacterium Rhodobacter sphaeroides is achieved by the unidirectional rotation of a single subpolar flagellum. In this study, transposon mutagenesis was used to obtain nonmotile flagellar mutants from this bacterium. We report here the isolation and characterization of a mutant that shows a polyhook phenotype. Morphological characterization of the mutant was done by electron microscopy. Polyhooks were obtained by shearing and were used to purify the hook protein monomer (FlgE). The apparent molecular mass of the hook protein was 50 kDa. N-terminal amino acid sequencing and comparisons with the hook proteins of other flagellated bacteria indicated that the Rhodobacter hook protein has consensus sequences common to axial flagellar components. A 25-kb fragment from an R. sphaeroides WS8 cosmid library restored wild-type flagellation and motility to the mutant. Using DNA adjacent to the inserted transposon as a probe, we identified a 4.6-kb SalI restriction fragment that contained the gene responsible for the polyhook phenotype. Nucleotide sequence analysis of this region revealed an open reading frame with a deduced amino acid sequence that was 23.4% identical to that of FliK of Salmonella typhimurium, the polypeptide responsible for hook length control in that enteric bacterium. The relevance of a gene homologous to fliK in the uniflagellated bacterium R. sphaeroides is discussed. PMID:9352903

  12. Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    2015-02-15

    PurposeWe retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS).MethodsEleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0.ResultsThe hook wire was successfully placed using the transfissural route in all but one case. Of these tenmore » successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed.ConclusionsThe transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.« less

  13. Effects of extensor synovectomy and excision of the distal ulna in rheumatoid arthritis on long-term function.

    PubMed

    Jain, Abhilash; Ball, Cathy; Freidin, Andrew J; Nanchahal, Jagdeep

    2010-09-01

    Objective outcomes data after excision of the distal ulna in rheumatoid arthritis are lacking. The aim of this study was to evaluate the functional results of this surgery in the long term. We prospectively collected data on range of motion (22 wrists), visual analog pain scores (14 wrists), and grip strength measured using a Jamar dynamometer (20 hands) in a group of 23 patients (26 wrists) preoperatively and at 3 months, 12 months, and a minimum of 5 years postoperatively (range, 5.3-10.4 y). The Jebsen-Taylor hand function test was administered to 9 patients at the same time points. A subgroup of patients also underwent extensor carpi radialis longus to extensor carpi ulnaris tendon transfer (11 wrists). At one year, there were improvements in wrist pronation and supination, which were maintained at final follow-up. Active radial deviation decreased significantly at 3 months (p = .01) and one year (p = .02); this remained reduced at final follow-up (not significant). Wrist extension and active ulnar deviation showed slight improvements by one year, but reduced to levels below that measured preoperatively by final follow-up. Wrist flexion was significantly reduced at all time points postoperatively. Grip strength showed improvement from 10.0 kg (standard deviation [SD] 4.1 kg) preoperatively to 12.5 kg (SD 4.6 kg) 1 year after surgery and returned to preoperative levels (9.5 kg, SD 5.6 kg) by final follow-up. Wrist pain was significantly reduced from a mean score of 5 (SD 4) preoperatively to 2 (SD 2) postoperatively (p = .01). The Jebsen-Taylor hand function test showed improvements in writing and card turning. In the long term, excision of the distal ulna in rheumatoid patients results in an improvement in some aspects of hand function. There is a significant (p = .01) reduction in wrist pain but a reduction of wrist flexion. Therapeutic IV. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Improvement for identification of heterophile antibody interference and AFP hook effect in immunoassays with multiplex suspension bead array system.

    PubMed

    Wang, Yajie; Yu, Jinsheng; Ren, Yuan; Liu, Li; Li, Haowen; Guo, Anchen; Shi, Congning; Fang, Fang; Juehne, Twyla; Yao, Jianer; Yang, Enhuan; Zhou, Xuelei; Kang, Xixiong

    2013-11-15

    A variety of immunoassays including multiplex suspension bead array have been developed for tumor marker detections; however, these assays could be compromised in their sensitivity and specificity by well-known heterophile antibody interference and hook effect. Using Luminex® multiplex suspension bead arrays, we modified protocols with two newly-developed solutions that can identify heterophile antibody interference and AFP hook effect. Effectiveness of the two solutions was assessed in serum samples from patients. Concentrations of 9 tumor markers in heterophile antibody positive samples assayed with Solution A, containing murine monoclonal antibodies and mouse serum, were significantly reduced when compared with those false high signals assayed without Solution A (all p<0.01). With incorporation of Solution H (fluorescent beads linked with AFP antigen), a new strategy for identification of AFP hook effect was established, and with this strategy AFP hook effect was identified effectively in serum samples with very high levels of AFP. Two proprietary solutions improve the identification of heterophile antibody interference and AFP hook effect. With these solutions, multiplex suspension bead arrays provide more reliable testing results in tumor marker detection where complex clinical serum samples are used. © 2013.

  15. Insights into the Functions of M-T Hook Structure in HIV Fusion Inhibitor Using Molecular Modeling.

    PubMed

    Tan, Jianjun; Yuan, Hongling; Li, Chunhua; Zhang, Xiaoyi; Wang, Cunxin

    2016-04-01

    HIV-1 membrane fusion plays an important role in the process that HIV-1 entries host cells. As a treatment strategy targeting HIV-1 entry process, fusion inhibitors have been proposed. Nevertheless, development of a short peptide possessing high anti-HIV potency is considered a daunting challenge. He et al. found that two residues, Met626 and Thr627, located the upstream of the C-terminal heptad repeat of the gp41, formed a unique hook-like structure (M-T hook) that can dramatically improve the binding stability and anti-HIV activity of the inhibitors. In this work, we explored the molecular mechanism why M-T hook structure could improve the anti-HIV activity of inhibitors. Firstly, molecular dynamic simulation was used to obtain information on the time evolution between gp41 and ligands. Secondly, based on the simulations, molecular mechanics Poisson-Boltzmann surface area (MM-PBSA) and molecular mechanics Generalized Born surface area (MM-GBSA) methods were used to calculate the binding free energies. The binding free energy of the ligand with M-T hook was considerably higher than the other without M-T. Further studies showed that the hydrophobic interactions made the dominant contribution to the binding free energy. The numbers of Hydrogen bonds between gp41 and the ligand with M-T hook structure were more than the other. These findings should provide insights into the inhibition mechanism of the short peptide fusion inhibitors and be useful for the rational design of novel fusion inhibitors in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Semi-rigid single hook localization the best method for localizing ground glass opacities during video-assisted thoracoscopic surgery: re-aerated swine lung experimental and primary clinical results

    PubMed Central

    Zhao, Guang; Sun, Long; Geng, Guojun; Liu, Hongming; Li, Ning; Liu, Suhuan; Hao, Bing

    2017-01-01

    Background The aim of this study was to compare the effects of currently available preoperative localization methods, including semi-rigid single hook-wire, double-thorn hook-wire, and microcoil, in localizing the pulmonary nodules, thus to select the best technology to assist video-assisted thoracoscopic surgery (VATS) for small ground glass opacities (GGO). Methods Preoperative CT-guided localizing techniques including semi-rigid single hook-wire, double-thorn hook-wire and microcoil were used in re-aerated fresh swine lung for location experiments. The advantages and drawbacks of the three positioning technologies were compared, and then the most optimal technique was used in patients with GGO. Technical success and post-operative complications were used as primary endpoints. Results All three localizing techniques were successfully performed in the re-aerated fresh swine lung. The median tractive force of semi-rigid single hook wire, double-thorn hook wire and microcoil were 6.5, 4.85 and 0.2 N, which measured by a spring dynamometer. The wound sizes in the superficial pleura, caused by unplugging the needles, were 2 mm in double-thorn hook wire, 1 mm in semi-rigid single hook and 1 mm in microcoil, respectively. In patients with GGOs, the semi-rigid hook wires localizations were successfully performed, without any complication that need to be intervened. Dislodgement was reported in one patient before VATS. No major complications related to the preoperative hook wire localization and VATS were observed. Conclusions We found from our localization experiments in the swine lung that, among the commonly used three localization methods, semi-rigid hook wire showed the best operability and practicability than double-thorn hook wire and microcoil. Preoperative localization of small pulmonary nodules with single semi-rigid hook wire system shows a high success rate, acceptable utility and especially low dislodgement in VATS. PMID:29312722

  17. Studying Hooke's Law by Using a Pogo Stick

    ERIC Educational Resources Information Center

    Silva, Nicolas

    2011-01-01

    Perhaps the pogo stick was little Robert Hooke's favorite childhood toy, consisting of a stiff spring inserted in a tube fixed at the upper end and connected to a moveable rod at the other. Hand grips and a foot rest are connected to the tube. The idea is to jump on it taking advantage of the force provided by the spring when it is compressed.…

  18. Transarticular fixation by hook plate versus coracoclavicular stabilization by single multistrand titanium cable for acute Rockwood grade-V acromioclavicular joint dislocation: a case-control study.

    PubMed

    Gao, You-Shui; Zhang, Yue-Lei; Ai, Zi-Sheng; Sun, Yu-Qiang; Zhang, Chang-Qing; Zhang, Wei

    2015-11-19

    Hook plate (HP) is popularly used for acute and severely displaced acromioclavicular (AC) dislocations. However, subacromial impingement and acromion osteolysis induced by transarticular fixation are notorious. The current case-control study was to compare transarticular fixation by HP to coracoclavicular (CC) stabilization by single multistrand titanium cable (MSTC). Between January 2006 and August 2009, 24 patients with acute AC dislocations were surgically treated by open reduction and transarticular fixation with HP. These patients were matched to a series of 24 patients, who were managed by CC stabilization with MSTC in the same period. All AC dislocations were graded as Rockwood type V. Implant was removed 8-12 months after the primary operation in all patients, and 12 months at least were needed to assess the maintenance of AC joint. Functional results were evaluated before implant removal as well as in the last follow-up based on Constant-Murley criteria. There were no differences of demographic data including age, dominant gender and side, injury-to-surgery interval, operation time and follow-up period. In terms of functionality, Constant score was 95.8 ± 4.1 in MSTC group, while 76.7 ± 8.0 in HP group before implant removal (P < 0.001). In detail, MSTC was superior to HP in pain, ROM and activities. Constant score was significantly improved to 86.1 ± 5.7 after hardware removal for patients in HP (P < 0.001). Degenerative change of acromioclavicular joint presented in 16 patients (66.7%) in patients treated by HP, while it was found in only 3 patients (12.5%) treated by MSTC (P < 0.001). MSTC is superior to HP for the treatment of Rockwood type-V acromioclavicular dislocation both before and after removal of the implant. Hardware removal is of great benefits for functional improvement in patients treated by HP.

  19. Specific arrangement of alpha-helical coiled coils in the core domain of the bacterial flagellar hook for the universal joint function.

    PubMed

    Fujii, Takashi; Kato, Takayuki; Namba, Keiichi

    2009-11-11

    The bacterial flagellar hook is a short, highly curved tubular structure connecting the rotary motor to the filament acting as a helical propeller. The bending flexibility of the hook allows it to work as a universal joint. A partial atomic model of the hook revealed a sliding intersubunit domain interaction along the protofilament to produce bending flexibility. However, it remained unclear how the tightly packed inner core domains can still permit axial extension and compression. We report advances in cryoEM image analysis for high-resolution, high-throughput structural analysis and a density map of the hook that reveals most of the secondary structures, including the terminal alpha helices forming a coiled coil. The orientations and axial packing interactions of these two alpha helices are distinctly different from those of the filament, allowing them to have a room for axial compression and extension for bending flexibility without impairing the mechanical stability of the hook.

  20. Histologic Evaluation of Critical Size Defect Healing With Natural and Synthetic Bone Grafts in the Pigeon ( Columba livia ) Ulna.

    PubMed

    Tunio, Ahmed; Jalila, Abu; Goh, Yong Meng; Shameha-Intan; Shanthi, Ganabadi

    2015-06-01

    Fracture and bone segment loss are major clinical problems in birds. Achieving bone formation and clinical union in a fracture case is important for the survival of the bird. To evaluate the efficacy of bone grafts for defect healing in birds, 2 different bone grafts were investigated in the healing of a bone defect in 24 healthy pigeons ( Columba livia ). In each bird, a 1-cm critical size defect (CSD) was created in the left ulna, and the fracture was stabilized with external skeletal fixation (ESF). A graft of hydroxyapatite (HA) alone (n = 12 birds) or demineralized bone matrix (DBM) combined with HA (n = 12 birds) was implanted in the CSD. The CSD healing was evaluated at 3 endpoints: 3, 6, and 12 weeks after surgery. Four birds were euthanatized at each endpoint from each treatment group, and bone graft healing in the ulna CSD was evaluated by histologic examination. The CSD and graft implants were evaluated for quality of union, cortex development, and bone graft incorporation. Results showed no graft rejection in any bird, and all birds had connective tissue formation in the defect because of the bone graft application. These results suggest that bone defect healing can be achieved by a combination of osteoinductive and osteoconductive bone graft materials for clinical union and new bone regeneration in birds. The combination of DBM and HA resulted in a better quality bone graft (P < .05) than did HA alone, but there was no significant differences in cortex development or bone graft incorporation at 3, 6, or 12 weeks. From the results of this study, we conclude that HA bone grafts, alone or in combination with DBM, with external skeletal fixation is suitable and safe for bone defect and fracture treatment in pigeons.

  1. 50 CFR 660.716 - Surface hook-and-line fishery. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Surface hook-and-line fishery. [Reserved] 660.716 Section 660.716 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OFF WEST COAST STATES...

  2. 50 CFR 660.716 - Surface hook-and-line fishery. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 11 2011-10-01 2011-10-01 false Surface hook-and-line fishery. [Reserved] 660.716 Section 660.716 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE (CONTINUED) FISHERIES OFF WEST COAST STATES...

  3. Rose Prickles and Asparagus Spines – Different Hook Structures as Attachment Devices in Climbing Plants

    PubMed Central

    Fiedler, Kathrin

    2015-01-01

    Functional morphology and biomechanical properties of hook structures functioning as attachment devices in the leaning climbers Rosa arvensis, Rosa arvensis ‘Splendens‘, Asparagus falcatus and Asparagus setaceus are analysed in order to investigate the variability in closely related species as well as convergent developments of hook structure and properties in distant systematic lineages (monocots and dicots). Prickles and spines were characterised by their size, orientation and the maximum force measured at failure in mechanical tests performed with traction forces applied at different angles. In Rosa arvensis and Rosa arvensis ‘Splendens‘ three types of prickles differing largely in geometrical and mechanical properties are identified (prickles of the wild species and two types of prickles in the cultivar). In prickles of Rosa arvensis no particular orientation of the prickle tip is found whereas in the cultivar Rosa arvensis ‘Splendens‘ prickles gradually gain a downward-orientation due to differential growth in the first weeks of their development. Differences in mechanical properties and modes of failure are correlated to geometrical parameters. In Asparagus falcatus and Asparagus setaceus spines are composed of leaf tissue, stem tissue and tissue of the axillary bud. Between species spines differ in size, orientation, distribution along the stem, tissue contributions and mechanical properties. The prickles of Rosa arvensis and its cultivar and the spines of the studied Asparagus species have several traits in common: (1) a gradual change of cell size and cell wall thickness, with larger cells in the centre and smaller thick-walled cells at the periphery of the hooks, (2) occurrence of a diversity of shape and geometry within one individual, (3) failure of single hooks when submitted to moderate mechanical stresses (Fmax/basal area < 35 N/mm²) and (4) failure of the hooks without severe stem damage (at least in the tested wild species). PMID

  4. Anterior cruciate ligament rupture secondary to a 'heel hook': a dangerous martial arts technique.

    PubMed

    Baker, Joseph F; Devitt, Brian M; Moran, Ray

    2010-01-01

    The 'heel hook' is a type of knee lock used in some forms of martial arts to stress the knee and cause opponent to concede defeat. While the knee is in a flexed and valgus disposition, an internal rotation force is applied to the tibia. Reports are lacking on serious knee trauma as a result of this technique. We report the case of a 32-year-old Mixed Martial Arts exponent who sustained complete anterior cruciate ligament rupture and an medial collateral ligament injury from the use of a 'heel hook'.

  5. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient.

    PubMed

    Williams, James; Wharton, Rupert; Peev, Peter; Horwitz, Maxim

    2018-06-01

    Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL) was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients.

  6. The Effects of Biomechanical Factors to Teach Different Hook Punch Techniques in Boxing and Education Strategies

    ERIC Educational Resources Information Center

    Bingul, Bergun Meric; Bulgun, Cigdem; Tore, Ozlem; Bal, Erdal; Aydin, Mensure

    2018-01-01

    The aim of this study was to investigate the effects of biomechanic factors to teach different hook punches in boxing. Eight light middleweight boxing athletes (mean age ± SD 19.00 ± 2.00 yrs, mean height ± SD 173.88 ± 3.89 cm, mean weight ± SD 64.25 ± 4.66 kg) participated in this study. Athletes performed a trial using three different hook punch…

  7. Comparative analysis of hook, hybrid, and pedicle screw instrumentation in the posterior treatment of adolescent idiopathic scoliosis.

    PubMed

    Yilmaz, Guney; Borkhuu, Battugs; Dhawale, Arjun A; Oto, Murat; Littleton, Aaron G; Mason, Dan E; Gabos, Peter G; Shah, Suken A

    2012-01-01

    Spinal instrumentation in adolescent idiopathic scoliosis (AIS) aims to correct spinal deformity and maintain long-term spinal stability until bony healing is ensured. The purpose of this study was to compare the minimum 2-year postoperative radiographic and clinical results of posterior spine correction and fusion with all-hook instrumentation versus hybrid segmental instrumentation versus pedicle screw instrumentation for AIS from a single institution. A total of 105 patients with AIS who underwent a posterior spinal fusion with segmental pedicle screw (35), hook (35), or hybrid (35) instrumentation were sorted and matched according to the following criteria: similar age at surgery, identical Lenke curve types, curve magnitude, and Risser grade. Patients were evaluated before, immediately after, and at 2 years after surgery for radiographic parameters, complications, and outcome, as well as on the basis of the Scoliosis Research Society (SRS) questionnaire. The age and Risser grade, major curve Cobb angle, apical vertebral rotation (AVR), apical vertebral translation (AVT), lowest instrumented vertebral tilt, global coronal and sagittal balance, lumbar lordosis, and thoracic kyphosis were determined as part of preoperative evaluation. All 3 groups showed significant differences between the preoperative and postoperative major curve Cobb angle, lowest instrumented vertebral tilt, AVT, and AVR. At the latest follow-up, lumbar lordosis, thoracic kyphosis, and global coronal and sagittal balance remained similar among the 3 groups. Major curve Cobb angle, AVT, and AVR were significantly different--the hook group's measurements were significantly higher than the other groups, but there was no difference between the pedicle screw and hybrid groups. Major curve correction rate was significantly different among all groups (screw=71.9%±13.8%, hybrid=61.4%±16.6%, hook=48.1%±19.7%) (P<0.001). The pedicle screw group had the least amount of correction loss but there was

  8. Antimicrobial properties of star anise (Illicium verum Hook f).

    PubMed

    De, Minakshi; De, Amit Krishna; Sen, Parimal; Banerjee, Arun Baran

    2002-02-01

    Star anise (Illicium verum Hook f) has been shown to possess potent antimicrobial properties. Chemical studies indicate that a major portion of this antimicrobial property is due to anethole present in the dried fruit. Studies with isolated anethole (compared with standard anethole) indicated that it is effective against bacteria, yeast and fungal strains. Copyright 2002 John Wiley & Sons, Ltd.

  9. A chromogranin A ELISA absent of an apparent high-dose hook effect observed in other chromogranin A ELISAs.

    PubMed

    Erickson, J Alan; Grenache, David G

    2016-01-15

    Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. DETAIL VIEW OF THE BRIDGE CRANE HOOKS USED IN HB3 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW OF THE BRIDGE CRANE HOOKS USED IN HB-3 AND HB-4, FACING SOUTHWEST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL

  11. 75 FR 7403 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    .... 0810141351-9087-02] RIN 0648-XU36 Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Catcher/Processors Using Hook-and-Line Gear in the Bering Sea and Aleutian Islands Management Area AGENCY: National... using hook-and-line gear in the Bering Sea and Aleutian Islands management area (BSAI). This action is...

  12. The Sandy Hook Elementary School shooting as tipping point

    PubMed Central

    Shultz, James M; Muschert, Glenn W; Dingwall, Alison; Cohen, Alyssa M

    2013-01-01

    Among rampage shooting massacres, the Sandy Hook Elementary School shooting on December 14, 2012 galvanized public attention. In this Commentary we examine the features of this episode of gun violence that has sparked strong reactions and energized discourse that may ultimately lead toward constructive solutions to diminish high rates of firearm deaths and injuries in the United States. PMID:28228989

  13. Development of an externally powered prosthetic hook for amputees

    NASA Technical Reports Server (NTRS)

    Karchak, A., Jr.; Allen, J. R.; Bontrager, E. L.

    1973-01-01

    The powered hook with trigger finger appears to be a useful adaptation of a terminal device for an amputee when performing vocational activities involving the use of a powered tool requiring a trigger control. The proportional control system includes transducers and amplifiers and appears to have widespread application for control of any external power, whether it be in the orthotic or prosthetic field.

  14. Upfront dilution of ferritin samples to reduce hook effect, improve turnaround time and reduce costs.

    PubMed

    Wu, Shu Juan; Hayden, Joshua A

    2018-02-15

    Sandwich immunoassays offer advantages in the clinical laboratory but can yield erroneously low results due to hook (prozone) effect, especially with analytes whose concentrations span several orders of magnitude such as ferritin. This study investigated a new approach to reduce the likelihood of hook effect in ferritin immunoassays by performing upfront, five-fold dilutions of all samples for ferritin analysis. The impact of this change on turnaround time and costs were also investigated. Ferritin concentrations were analysed in routine clinical practice with and without upfront dilutions on Siemens Centaur® XP (Siemens Healthineers, Erlang, Germany) immunoanalysers. In addition, one month of baseline data (1026 results) were collected prior to implementing upfront dilutions and one month of data (1033 results) were collected after implementation. Without upfront dilutions, hook effect was observed in samples with ferritin concentrations as low as 86,028 µg/L. With upfront dilutions, samples with ferritin concentrations as high as 126,050 µg/L yielded values greater than the measurement interval and would have been diluted until an accurate value was obtained. The implementation of upfront dilution of ferritin samples led to a decrease in turnaround time from a median of 2 hours and 3 minutes to 1 hour and 18 minutes (P = 0.002). Implementation of upfront dilutions of all ferritin samples reduced the possibility of hook effect, improved turnaround time and saved the cost of performing additional dilutions.

  15. Hooked on the nicotine addiction thesis: a response to DiFranza.

    PubMed

    Dar, Reuven; Frenk, Hanan

    2013-11-18

    DiFranza's rebuttal to our critique of the "Hooked on Nicotine" research program misconstrues our arguments beyond recognition. The grossest misrepresentation of our critique by DiFranza is that we devise (by thwarting science) to rescue "the conventional wisdom" of the "threshold model of nicotine addiction." In fact, the difference between our positions lies elsewhere: We believe that nicotine is not an addictive drug and that its contribution to the smoking habit is secondary; DiFranza believes that nicotine is so powerfully addictive that novice smokers can lose autonomy over their smoking behavior after one cigarette or even following a single puff. Our review aimed to critically examine the empirical basis of this extreme version of the nicotine "addiction" model. In this brief commentary we illustrate how the commitment to the nicotine "addiction" theory has biased the methodology and the interpretation of the data in "Hooked on Nicotine" research program.

  16. [Comparing the anchorage effects of micro-implant and J hook on treating patients with maxillary protrusion].

    PubMed

    Wu, Xin; Liu, Guo-yuan; Jiang, Yong-lian

    2015-10-01

    To investigate the differences in anchorage effects between micro-implants and J hook in treating patients with Class II division 1 maxillary protrusion. Thirty-one cases of adult patients with Class II division 1 maxillary protrusion were treated. They were divided into 2 groups depending on their selection. The first group included 17 patients for micro-implant anchorage, who adopted micro-implant and sliding mechanism to close maxillary extraction space and depress the mandibular molar. The second group encompassed 14 cases for J hook, who adopted sliding mechanism, J hooks in high traction and Class II intermaxillary traction to close extraction space. X-ray lateral cephalometric radiographs were measured before and after treatment, and SPSS16.0 software package was employed to compare the differences in soft and hard tissue changes before and after treatment between 2 groups. There were statistically significant differences in SNB, ANB, MP-FH, U1-Y, U6-Y, L6-MP, NLA, and UL-Y between the 2 groups before and after treatment, while there was no significant difference in SNA, U1-SN, U1-X, and U6-X between the 2 groups. In treating patients with Class II division 1 maxillary protrusion, micro-implant has stronger anchorage effects than J hook, while at the same time depressing the mandibular molars, and making it more favorable to improve Class II faces.

  17. "Hook"-calibration of GeneChip-microarrays: theory and algorithm.

    PubMed

    Binder, Hans; Preibisch, Stephan

    2008-08-29

    : The improvement of microarray calibration methods is an essential prerequisite for quantitative expression analysis. This issue requires the formulation of an appropriate model describing the basic relationship between the probe intensity and the specific transcript concentration in a complex environment of competing interactions, the estimation of the magnitude these effects and their correction using the intensity information of a given chip and, finally the development of practicable algorithms which judge the quality of a particular hybridization and estimate the expression degree from the intensity values. : We present the so-called hook-calibration method which co-processes the log-difference (delta) and -sum (sigma) of the perfect match (PM) and mismatch (MM) probe-intensities. The MM probes are utilized as an internal reference which is subjected to the same hybridization law as the PM, however with modified characteristics. After sequence-specific affinity correction the method fits the Langmuir-adsorption model to the smoothed delta-versus-sigma plot. The geometrical dimensions of this so-called hook-curve characterize the particular hybridization in terms of simple geometric parameters which provide information about the mean non-specific background intensity, the saturation value, the mean PM/MM-sensitivity gain and the fraction of absent probes. This graphical summary spans a metrics system for expression estimates in natural units such as the mean binding constants and the occupancy of the probe spots. The method is single-chip based, i.e. it separately uses the intensities for each selected chip. : The hook-method corrects the raw intensities for the non-specific background hybridization in a sequence-specific manner, for the potential saturation of the probe-spots with bound transcripts and for the sequence-specific binding of specific transcripts. The obtained chip characteristics in combination with the sensitivity corrected probe

  18. THE BLUE HOOK POPULATIONS OF MASSIVE GLOBULAR CLUSTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Thomas M.; Smith, Ed; Sweigart, Allen V.

    2010-08-01

    We present new Hubble Space Telescope ultraviolet color-magnitude diagrams of five massive Galactic globular clusters: NGC 2419, NGC 6273, NGC 6715, NGC 6388, and NGC 6441. These observations were obtained to investigate the 'blue hook' (BH) phenomenon previously observed in UV images of the globular clusters {omega} Cen and NGC 2808. Blue hook stars are a class of hot (approximately 35,000 K) subluminous horizontal branch stars that occupy a region of the HR diagram that is unexplained by canonical stellar evolution theory. By coupling new stellar evolution models to appropriate non-LTE synthetic spectra, we investigate various theoretical explanations for thesemore » stars. Specifically, we compare our photometry to canonical models at standard cluster abundances, canonical models with enhanced helium (consistent with cluster self-enrichment at early times), and flash-mixed models formed via a late helium-core flash on the white dwarf cooling curve. We find that flash-mixed models are required to explain the faint luminosity of the BH stars, although neither the canonical models nor the flash-mixed models can explain the range of color observed in such stars, especially those in the most metal-rich clusters. Aside from the variation in the color range, no clear trends emerge in the morphology of the BH population with respect to metallicity.« less

  19. Allogeneic adipose-derived stem cells regenerate bone in a critical-sized ulna segmental defect

    PubMed Central

    Wen, Congji; Yan, Hai; Fu, Shibo; Qian, Yunliang

    2016-01-01

    Adipose-derived stem cells (ASCs) with multilineage potential can be induced into osteoblasts, adipocytes and chondrocytes. ASCs as seed cell are widely used in the field of tissue engineering, but most studies either use autologous cells as the source or an immunodeficient animal as the host. In our present study, we explored the feasibility of applying allogeneic ASCs and demineralized bone matrix (DBM) scaffolds for repairing tubular bone defects without using immunosuppressive therapy. Allogeneic ASCs were expanded and seeded on DBM scaffolds and induced to differentiate along the osteogenic lineage. Eight Sprague–Dawley (SD) rats were used in this study and bilateral critical-sized defects (8 mm) of the ulna were created and divided into two groups: with ASC-DBM constructs or DBM alone. The systemic immune response and the extent of bone healing were evaluated post-operatively. Twenty-four weeks after implantation, digital radiography (DR) testing showed that new bones had formed in the experimental group. By contrast, no bone tissue formation was observed in the control group. This study demonstrated that allogeneic ASCs could promote bone regeneration and repair tubular bone defects combined with DBM by histologically typical bone without systemic immune response PMID:25819682

  20. Laparoscopic inguinal hernia repair by the hook method in emergency setting in children presenting with incarcerated inguinal hernia.

    PubMed

    Chan, Kin Wai Edwin; Lee, Kim Hung; Tam, Yuk Him; Sihoe, Jennifer Dart Yin; Cheung, Sing Tak; Mou, Jennifer Wai Cheung

    2011-10-01

    The development of laparoscopic hernia repair has provided an alternative approach to the management of incarcerated inguinal hernia in children. Different laparoscopic techniques for hernia repair have been described. However, we hereby review the role of laparoscopic hernia repair using the hook method in the emergency setting for incarcerated inguinal hernias in children. A retrospective review was conducted of all children who presented with incarcerated inguinal hernia and underwent laparoscopic hernia repair using the hook method in emergency setting between 2004 and 2010. There were a total of 15 boys and 1 girl with a mean age of 30 ± 36 months (range, 4 months to 12 years). The hernia was successfully reduced after sedation in 7 children and after general anesthesia in 4 children. In 5 children, the hernia was reduced by a combined manual and laparoscopic-assisted approach. Emergency laparoscopic inguinal hernia repair using the hook method was performed after reduction of the hernia. The presence of preperitoneal fluid secondary to recent incarceration facilitated the dissection of the preperitoneal space by the hernia hook. All children underwent successful reduction and hernia repair. The median operative time was 37 minutes. There was no postoperative complication. The median hospital stay was 3 days. At a median follow-up of 40 months, there was no recurrence of the hernia or testicular atrophy. Emergency laparoscopic inguinal hernia repair by the hook method is safe and feasible. Easier preperitoneal dissection was experienced, and repair of the contralateral patent processus vaginalis can be performed in the same setting. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. The HOOK region of voltage-gated Ca2+ channel β subunits senses and transmits PIP2 signals to the gate.

    PubMed

    Park, Cheon-Gyu; Park, Yongsoo; Suh, Byung-Chang

    2017-02-01

    The β subunit of voltage-gated Ca 2+ (Ca V ) channels plays an important role in regulating gating of the α1 pore-forming subunit and its regulation by phosphatidylinositol 4,5-bisphosphate (PIP 2 ). Subcellular localization of the Ca V β subunit is critical for this effect; N-terminal-dependent membrane targeting of the β subunit slows inactivation and decreases PIP 2 sensitivity. Here, we provide evidence that the HOOK region of the β subunit plays an important role in the regulation of Ca V biophysics. Based on amino acid composition, we broadly divide the HOOK region into three domains: S (polyserine), A (polyacidic), and B (polybasic). We show that a β subunit containing only its A domain in the HOOK region increases inactivation kinetics and channel inhibition by PIP 2 depletion, whereas a β subunit with only a B domain decreases these responses. When both the A and B domains are deleted, or when the entire HOOK region is deleted, the responses are elevated. Using a peptide-to-liposome binding assay and confocal microscopy, we find that the B domain of the HOOK region directly interacts with anionic phospholipids via polybasic and two hydrophobic Phe residues. The β2c-short subunit, which lacks an A domain and contains fewer basic amino acids and no Phe residues in the B domain, neither associates with phospholipids nor affects channel gating dynamically. Together, our data suggest that the flexible HOOK region of the β subunit acts as an important regulator of Ca V channel gating via dynamic electrostatic and hydrophobic interaction with the plasma membrane. © 2017 Park et al.

  2. The Bare Area of the Proximal Ulna: An Anatomic Study With Relevance to Chevron Osteotomy.

    PubMed

    Ao, Rongguang; Zhang, Xu; Li, Dejian; Chen, Fancheng; Zhou, Jianhua; Yu, Baoqing

    2017-06-01

    A chevron osteotomy of the ulna is widely used to obtain intra-articular access to the elbow in the treatment of type C distal humerus fractures. The trochlear notch of the proximal ulna is divided into 2 articular parts by the "bare area." Ideally, the olecranon osteotomy should be centered on the bare area to minimize damage to the joint cartilage. The goals of this study were to describe the anatomy of the bare area and design an ideal chevron-shaped osteotomy. We dissected 38 cadaver elbows and measured the width of the bare area, the distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area. We then designed a chevron osteotomy to stay within the bare area and measured the distance from the tip of the triceps insertion to the osteotomy apex as well as the angle of the osteotomy plane and the angle of the chevron cuts. The bare area existed in all 38 cadavers. The mean longitudinal and transverse widths were 4.0 mm (range, 1.0-8.6 mm) and 19.0 mm (range, 16.9-23.8 mm), respectively. The mean distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area was 19.0 mm (range, 16.0-23.0 mm). The mean transverse and longitudinal widths of the cortical notch were 3.0 mm (range, 1.6-4.5 mm) and 8.0 mm (range, 6.5-14.8 mm), respectively. The mean distance between the tip of the triceps insertion and the osteotomy apex was 22.0 mm (range, 18.0-24.0 mm) and the mean angle between the osteotomy surface and the vertical plane corresponding to the tangent plane was 20° (range, 10° to 25°). The mean angle of the V shape was 140° (range, 130° to 150°). Using the narrowest edge lacking cartilage (lateral or medial side) as a point of reference to locate the bare area, the designed chevron osteotomy entered the joint in the bare area in most specimens and decreased associated damage to the joint cartilage. This study describes the anatomy of the bare area and

  3. Cheating, Hooking Up, and Attention to Romantic Alternatives among College Students

    ERIC Educational Resources Information Center

    Buri, John R.; Cromett, Cristina E.; Pappas, Sarah J.

    2014-01-01

    While numerous studies have emphasized more situational factors related to cheating, hooking up, and attention to romantic alternatives (e.g., alcohol use, need fulfillment, opportunity), the present findings support Finkel el al.'s (2012) argument for greater attentiveness to personal factors intrinsic to the individual that may influence…

  4. Hook nozzle arrangement for supporting airfoil vanes

    DOEpatents

    Shaffer, James E.; Norton, Paul F.

    1996-01-01

    A gas turbine engine's nozzle structure includes a nozzle support ring, a plurality of shroud segments, and a plurality of airfoil vanes. The plurality of shroud segments are distributed around the nozzle support ring. Each airfoil vane is connected to a corresponding shroud segment so that the airfoil vanes are also distributed around the nozzle support ring. Each shroud segment has a hook engaging the nozzle support ring so that the shroud segments and corresponding airfoil vanes are supported by the nozzle support ring. The nozzle support ring, the shroud segments, and the airfoil vanes may be ceramic.

  5. Hook nozzle arrangement for supporting airfoil vanes

    DOEpatents

    Shaffer, J.E.; Norton, P.F.

    1996-02-20

    A gas turbine engine`s nozzle structure includes a nozzle support ring, a plurality of shroud segments, and a plurality of airfoil vanes. The plurality of shroud segments are distributed around the nozzle support ring. Each airfoil vane is connected to a corresponding shroud segment so that the airfoil vanes are also distributed around the nozzle support ring. Each shroud segment has a hook engaging the nozzle support ring so that the shroud segments and corresponding airfoil vanes are supported by the nozzle support ring. The nozzle support ring, the shroud segments, and the airfoil vanes may be ceramic. 8 figs.

  6. Characteristic Chromatogram: A Method of Discriminate and Quantitative Analysis for Quality Evaluation of Uncaria Stem with Hooks.

    PubMed

    Hou, Jinjun; Feng, Ruihong; Zhang, Yibei; Pan, Huiqin; Yao, Shuai; Han, Sumei; Feng, Zijin; Cai, Luying; Wu, Wanying; Guo, De-An

    2018-04-01

    It remains a challenge to establish new monographs for herbal drugs derived from multiple botanical sources. Specifically, the difficulty involves discriminating and quantifying these herbs with components whose levels vary markedly among different samples. Using Uncaria stem with hooks as an example, a characteristic chromatogram was proposed to discriminate its five botanical origins and to quantify its characteristic components in the chromatogram. The characteristic chromatogram with respect to the components of Uncaria stem with hooks with the five botanical origins was established using 0.02% diethylamine and acetonitrile as the mobile phase. The total analysis time was 50 min and the detection wavelength was 245 nm. Using the same chromatogram parameters, the single standard to determine multicomponents method was validated to simultaneously quantify nine indole alkaloids, including vincosamide, 3 α -dihydrocadambine, isocorynoxeine, corynoxeine, isorhynchophylline, rhynchophylline, hirsuteine, hirsutine, and geissoschizine methyl ether. The results showed that only the Uncaria stem with hooks from Uncaria rhynchophylla , the most widely used in the herbal market, showed the presence of these nine alkaloids. The conversion factors were 1.27, 2.32, 0.98, 1.04, 1.00, 1.02, 1.26, 1.33, and 1.25, respectively. The limits of quantitation were lower than 700 ng/mL. The total contents of 31 batches of Uncaria stem with hooks were in the range of 0.1 - 0.6%, except for Uncaria hirsuta Havil and Uncaria sinensis (Oliv.) Havil. The results also showed that the total content of indole alkaloids tended to decrease with an increase in the hook diameter. This showed that the characteristic chromatogram is practical for controlling the quality of traditional Chinese medicines with multiple botanical origins. Georg Thieme Verlag KG Stuttgart · New York.

  7. Rapidly rotating second-generation progenitors for the 'blue hook' stars of ω Centauri.

    PubMed

    Tailo, Marco; D'Antona, Francesca; Vesperini, Enrico; Di Criscienzo, Marcella; Ventura, Paolo; Milone, Antonino P; Bellini, Andrea; Dotter, Aaron; Decressin, Thibaut; D'Ercole, Annibale; Caloi, Vittoria; Capuzzo-Dolcetta, Roberto

    2015-07-16

    Horizontal branch stars belong to an advanced stage in the evolution of the oldest stellar galactic population, occurring either as field halo stars or grouped in globular clusters. The discovery of multiple populations in clusters that were previously believed to have single populations gave rise to the currently accepted theory that the hottest horizontal branch members (the 'blue hook' stars, which had late helium-core flash ignition, followed by deep mixing) are the progeny of a helium-rich 'second generation' of stars. It is not known why such a supposedly rare event (a late flash followed by mixing) is so common that the blue hook of ω Centauri contains approximately 30 per cent of the horizontal branch stars in the cluster, or why the blue hook luminosity range in this massive cluster cannot be reproduced by models. Here we report that the presence of helium core masses up to about 0.04 solar masses larger than the core mass resulting from evolution is required to solve the luminosity range problem. We model this by taking into account the dispersion in rotation rates achieved by the progenitors, whose pre-main-sequence accretion disk suffered an early disruption in the dense environment of the cluster's central regions, where second-generation stars form. Rotation may also account for frequent late-flash-mixing events in massive globular clusters.

  8. Interview with 2018 Hooke medal winner Andrew McAinsh.

    PubMed

    2018-03-14

    Andrew McAinsh received his PhD from the University of Cambridge, UK, working in the laboratory of Steve Jackson on DNA damage and repair mechanisms in yeast. He then joined the laboratory of Peter Sorger as a Jane Coffin Childs Fellow to work as a post-doc on kinetochore biology at the Massachusetts Institute of Technology, Boston, USA. In 2005, he returned to the UK to establish his independent laboratory at the Marie Curie Research Institute, Surrey, before moving to the University of Warwick in 2009 to co-found the Centre for Mechanochemical Cell Biology (CMCB). Subsequently, Andrew was appointed Professor of Cell Biology and became a Wellcome Senior Investigator, and was awarded a Royal Society Wolfson Research Merit Award. He co-directs the MRC Doctoral Training Partnership in Interdisciplinary Biomedical Research, and in 2017 became Head of Division of Biomedical Sciences at Warwick Medical School. Andrew is interested in understanding how the chromosomal multi-protein complex, the kinetochore, ensures error-free chromosome segregation. He is the recipient of the 2018 Hooke medal, established to recognize an emerging leader in cell biology. The Hooke medal is awarded at the annual spring meeting of the British Society for Cell Biology (BSCB). © 2018. Published by The Company of Biologists Ltd.

  9. Single-port thoracoscopic sympathicotomy using a double-lumen electrocautery tube and cautery hook for primary palmar hyperhidrosis: a randomized controlled trial.

    PubMed

    Jin, Cheng-Hua; Liu, Kai; Yu, Kai-Zhong; Tian, Hui; Mao, Zheng-Chun; Shen, Wei-Yu

    2014-08-01

    The objective of this study is to assess the use of a novel, double-lumen electrocautery tube (DLET) device for ablating the sympathetic nerve chain in patients with primary palmar hyperhidrosis (PPH). Forty-six patients with severe PPH were recruited into the study between November 2010 and February 2012. All patients underwent single port, bilateral video-assisted thoracoscopic sympathicotomy. Twenty-four patients were randomized to receive sympathicotomy using a conventional 5-mm electrocautery hook (hook group) and 22 patients were randomized to the DLET group. The mean postoperative follow-up period was 8.1 months (range: 1 to 15 months). After surgery the hands of all patients became dry and warm. Mean incision size was 10.6 ± 1.0 in the hook group and 6.5 ± 0.5 mm in the DLET group (p = 0.001). The mean pain score was 1.4 ± 0.6 with hook surgery and 0.9 ± 0.6 with the DLET device (p = 0.016). The mean operative time was longer in the hook group (36.8 ± 3.4 min) than in the DLET group (30.5 ± 3.9 min; p = 0.001). There were no significant differences between the two procedures in terms of hospital stay and compensatory sweating, or patient satisfaction. Pneumothorax occurred in two (8.3%) patients in the hook group and in one (4.5%) patient in the DLET group. None of the patients required chest drainage and none developed Horner syndrome. Single-port video-assisted thoracoscopic sympathicotomy using hook or DLET procedures is effective, safe, and minimally invasive method for palmar hyperhidrosis. The DLET device allows a shorter operation time, smaller incision, better cosmetic results, less pain, and better clarity of video, making it suitable for single-port thoracoscopic sympathicotomy. Georg Thieme Verlag KG Stuttgart · New York.

  10. Treatment and evolution of grade III acromioclavicular dislocations in soccer players.

    PubMed

    Pereira-Graterol, Ernesto; Álvarez-Díaz, Pedro; Seijas, Roberto; Ares, Oscar; Cuscó, Xavier; Cugat, Ramón

    2013-07-01

    To evaluate postoperative functional results in soccer players diagnosed with acute grade III acromioclavicular dislocation, stabilized with clavicular hook plate. Between 2006 and 2010, 11 soccer players were diagnosed with acute acromioclavicular dislocation. Mean age was 22.9 years. The clavicular hook plate was used for stabilization. The follow-up was 4 years (2-6 years). Constant score showed 82 % excellent results and 18 % good functional results. Average pain measured with VAS was 1.8 (±0.59) mm out of 10. We did not report any complication within the process. Use of the clavicular hook plate is considered adequate for the treatment of acute acromioclavicular dislocation in soccer players, allowing a quick return to sports. Retrospective case series, Level IV.

  11. Hook is an adapter that coordinates kinesin-3 and dynein cargo attachment on early endosomes

    PubMed Central

    Bielska, Ewa; Schuster, Martin; Roger, Yvonne; Berepiki, Adokiye; Soanes, Darren M.; Talbot, Nicholas J.

    2014-01-01

    Bidirectional membrane trafficking along microtubules is mediated by kinesin-1, kinesin-3, and dynein. Several organelle-bound adapters for kinesin-1 and dynein have been reported that orchestrate their opposing activity. However, the coordination of kinesin-3/dynein-mediated transport is not understood. In this paper, we report that a Hook protein, Hok1, is essential for kinesin-3– and dynein-dependent early endosome (EE) motility in the fungus Ustilago maydis. Hok1 binds to EEs via its C-terminal region, where it forms a complex with homologues of human fused toes (FTS) and its interactor FTS- and Hook-interacting protein. A highly conserved N-terminal region is required to bind dynein and kinesin-3 to EEs. To change the direction of EE transport, kinesin-3 is released from organelles, and dynein binds subsequently. A chimaera of human Hook3 and Hok1 rescues the hok1 mutant phenotype, suggesting functional conservation between humans and fungi. We conclude that Hok1 is part of an evolutionarily conserved protein complex that regulates bidirectional EE trafficking by controlling attachment of both kinesin-3 and dynein. PMID:24637326

  12. The validation of a generalized Hooke's law for coronary arteries.

    PubMed

    Wang, Chong; Zhang, Wei; Kassab, Ghassan S

    2008-01-01

    The exponential form of constitutive model is widely used in biomechanical studies of blood vessels. There are two main issues, however, with this model: 1) the curve fits of experimental data are not always satisfactory, and 2) the material parameters may be oversensitive. A new type of strain measure in a generalized Hooke's law for blood vessels was recently proposed by our group to address these issues. The new model has one nonlinear parameter and six linear parameters. In this study, the stress-strain equation is validated by fitting the model to experimental data of porcine coronary arteries. Material constants of left anterior descending artery and right coronary artery for the Hooke's law were computed with a separable nonlinear least-squares method with an excellent goodness of fit. A parameter sensitivity analysis shows that the stability of material constants is improved compared with the exponential model and a biphasic model. A boundary value problem was solved to demonstrate that the model prediction can match the measured arterial deformation under experimental loading conditions. The validated constitutive relation will serve as a basis for the solution of various boundary value problems of cardiovascular biomechanics.

  13. Multi-type Tectonic Responses to Plate Motion Changes of Mega-Offset Transform Faults at the Pacific-Antarctic Ridge

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Lin, J.; Yang, H.; Zhou, Z.

    2017-12-01

    Magmatic and tectonic responses of a mid-ocean ridge system to plate motion changes can provide important constraints on the mechanisms of ridge-transform interaction and lithospheric properties. Here we present new analysis of multi-type responses of the mega-offset transform faults at the Pacific-Antarctic Ridge (PAR) system to plate motion changes in the last 12 Ma. Detailed analysis of the Heezen, Tharp, and Udintsev transform faults showed that the extensional stresses induced by plate motion changes could have been released through a combination of magmatic and tectonic processes: (1) For a number of ridge segments with abundant magma supply, plate motion changes might have caused the lateral transport of magma along the ridge axis and into the abutting transform valley, forming curved "hook" ridges at the ridge-transform intersection. (2) Plate motion changes might also have caused vertical deformation on steeply-dipping transtensional faults that were developed along the Heezen, Tharp, and Udintsev transform faults. (3) Distinct zones of intensive tectonic deformation, resembling belts of "rift zones", were found to be sub-parallel to the investigated transform faults. These rift-like deformation zones were hypothesized to have developed when the stresses required to drive the vertical deformation on the steeply-dipping transtensional faults along the transform faults becomes excessive, and thus deformation on off-transform "rift zones" became favored. (4) However, to explain the observed large offsets on the steeply-dipping transtensional faults, the transform faults must be relatively weak with low apparent friction coefficient comparing to the adjacent lithospheric plates.

  14. [Direct repair of adolescent lumbar spondylolysis using a pedicle screw-laminar hook system by paramedian approach].

    PubMed

    Wang, Bin; Tang, Yong-hua; Tang, Hong-chao; Jin, Cai-yi

    2011-08-01

    To discuss the indication and clinical effect of direct repair of adolescent lumbar spondylolysis by screw-laminar hook system. From August 2003 to December 2008, 28 patients (13 males and 15 females,ranging in age from 15 and 26 years, averaged 21.6 years) with lumbar spondylolysis were treated with isthmic bone grafting and internal fixation with a pedicle screw-laminar hook system. Three patients had spondylolysis at L3, L4; 5 patients had spondylolysis at L4, L5; 8 patients had spondylolysis at L4; and 12 patients had spondylolysis at L5. All the patients had low back pain and lasted over 6 months. According to preoperative and postoperative plain radiograph, CT scan and Macnab criteria, the fusion rate and clinical effect of this technique were evaluated. All the patients were followed up with a mean period of 14.9 months, ranging from 9 to 24 months. All the patients had bony union according to the X-rays and CT scan. According to the calculation results of Macnab criteria, 22 patients got an excellent result, 5 good and 1 fair. The direct repair of adolescent lumbar spondylolysis with pedicle screw-laminar hook system can shorten length of operation,decrease blood loss, preserve more posterior structures of spine and avoid iatrogenic instability of spine. The postoperative immediate stability of vertebral segment is acquired and the mobility of adjacent intervertebral discs is reserved. The screw-laminar hook system for the treatment of adolescent spondylolisthesis can get satisfactory clinical results.

  15. Does Hooke's law work in helical nanosprings?

    PubMed

    Ben, Sudong; Zhao, Junhua; Rabczuk, Timon

    2015-08-28

    Hooke's law is a principle of physics that states that the force needed to extend a spring by some distance is proportional to that distance. The law is always valid for an initial portion of the elastic range for nearly all helical macrosprings. Here we report the sharp nonlinear force-displacement relation of tightly wound helical carbon nanotubes at even small displacement via a molecular mechanics model. We demonstrate that the van der Waals (vdW) interaction between the intertube walls dominates the nonlinear relation based on our analytical expressions. This study provides physical insights into the origin of huge nonlinearity of the helical nanosprings.

  16. Disseminated gestational choriocarcinoma presenting with hepatic and uveal metastases, hook effect, and choriocarcinoma syndrome.

    PubMed

    Aswani, Yashant; Thakkar, Hemangini; Hira, Priya

    2016-01-01

    Choriocarcinoma is a human chorionic gonadotrophin (HCG)-secreting tumor that comprises vascular channels. It has a tendency for widespread metastasis, common sites for which include the lung, vagina, brain, liver, bone, intestine, and kidney. We describe a 30-year-old female who presented with hepatitis-like features and bilateral diminution of vision, and subsequently developed hemothorax and hemoperitoneum-all rare and seemingly unrelated manifestations which were finally attributable to metastases from gestational choriocarcinoma. To further complicate the clinical scenario, the serum HCG of the patient was mildly raised (due to a phenomenon called hook effect). Subsequently, the patient developed disseminated intravascular coagulation and succumbed to her illness. In this report, we discuss the imaging findings of choriocarcinoma, its potential sites of metastases, and the hook effect.

  17. GOS hook type wells, directional planning, techniques applied and problems encountered

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A /Azim, M.; Fahmy, H.; Salem, A.

    1995-10-01

    This paper addresses the various aspects of hook type wells introduced and drilled within GUPCO operations during he last two years. The first well of this category was October-G10, drilled in October 1992 from October ``G`` platform to a target point in the Nubia formation. Several wells of the same type have been drilled through 1993 and 1994. This group includes October-H1, Ramadan 3-57, July 62-69 and SB 374-3. Drilling hook type well profiles has resulted in increased production and more reserve recovery. The driving force behind using this profile was the reservoir requirements where it was required to hitmore » a target within few meters at a certain angle and direction. Torque and drag models have been used to optimize well path planning, resulting in lower torque and drag values. Daily pot appraisal of the drilling operations to monitor hole cleaning effectiveness. Combination of advanced steerable systems and PDC bits enabled GUPCO to drill these wells cost effectively.« less

  18. The role of sediment compaction and groundwater withdrawal in local sea-level rise, Sandy Hook, New Jersey, USA

    NASA Astrophysics Data System (ADS)

    Johnson, Christopher S.; Miller, Kenneth G.; Browning, James V.; Kopp, Robert E.; Khan, Nicole S.; Fan, Ying; Stanford, Scott D.; Horton, Benjamin P.

    2018-02-01

    The rate of relative sea-level (RSL) rise at Sandy Hook, NJ (4.0 ± 0.5 mm/yr) was higher than The Battery, NY (3.0 ± 0.3 mm/yr) from 1900 to 2012 despite being separated by just 26 km. The difference cannot be explained by differential glacial isostatic adjustment (GIA; 1.4 ± 0.4 and 1.3 ± 0.4 mm/yr RSL rise, respectively) alone. We estimate the contribution of sediment compaction to subsidence at Sandy Hook using high-resolution grain size, percent organic matter, and porosity data from three upper Quaternary (≤13,350 cal yr) cores. The organic matter content (<2%) is too low to contribute to local subsidence. However, numerical modeling of the grain size-depth-age-porosity relationship indicates that compaction of deglacial silts likely reduced the column thickness by 10-20% over the past 13,350 cal yrs. While compaction rates were high immediately after the main silt deposition (13,350-13,150 cal yrs BP), rates decreased exponentially after deposition to an average 20th century rate of 0.16 mm/yr (90% Confidence Interval (C.I.), 0.06-0.32 mm/yr). The remaining ∼0.7 mm/yr (90% C.I. 0.3-1.2 mm/yr) difference in subsidence between Sandy Hook and The Battery is likely due to anthropogenic groundwater withdrawal. Historical data from Fort Hancock wells (2 km to the southeast of the Sandy Hook tide gauge) and previous regional work show that local and regional water extraction lowered the water levels in the aquifers underlying Sandy Hook. We suggest that the modern order of contribution to subsidence (highest to lowest) appears to be GIA, local/regional groundwater extraction, and compaction of thick Quaternary silts.

  19. Evaluation of wheelchair seating system crashworthiness: "drop hook"-type seat attachment hardware.

    PubMed

    Bertocci, G; Ha, D; Deemer, E; Karg, P

    2001-04-01

    To evaluate the crashworthiness of commercially available hardware that attaches seat surfaces to the wheelchair frame. A low cost static crashworthiness test procedure that simulates a frontal impact motor vehicle crash. Safety testing laboratory. Eleven unique sets of drop-hook hardware made of carbon steel (4), stainless steel (4), and aluminum (3). Replicated seat-loading conditions associated with a 20g/48 kph frontal impact. Test criterion for seat loading was 16,680 N (3750 lb). Failure load and deflection of seat surface. None of the hardware sets tested met the crashworthiness test criterion. All failed at less than 50% of the load that seating hardware could be exposed to in a 20g/48 kph frontal impact. The primary failure mode was excessive deformation, leading to an unstable seat support surface. Results suggest that commercially available seating drop hooks may be unable to withstand loading associated with a frontal crash and may not be the best option for use with transport wheelchairs.

  20. Eigenstates and dynamics of Hooke's atom: Exact results and path integral simulations

    NASA Astrophysics Data System (ADS)

    Gholizadehkalkhoran, Hossein; Ruokosenmäki, Ilkka; Rantala, Tapio T.

    2018-05-01

    The system of two interacting electrons in one-dimensional harmonic potential or Hooke's atom is considered, again. On one hand, it appears as a model for quantum dots in a strong confinement regime, and on the other hand, it provides us with a hard test bench for new methods with the "space splitting" arising from the one-dimensional Coulomb potential. Here, we complete the numerous previous studies of the ground state of Hooke's atom by including the excited states and dynamics, not considered earlier. With the perturbation theory, we reach essentially exact eigenstate energies and wave functions for the strong confinement regime as novel results. We also consider external perturbation induced quantum dynamics in a simple separable case. Finally, we test our novel numerical approach based on real-time path integrals (RTPIs) in reproducing the above. The RTPI turns out to be a straightforward approach with exact account of electronic correlations for solving the eigenstates and dynamics without the conventional restrictions of electronic structure methods.

  1. Tracks in the Sand: Hooke's Pendulum "Cum Grano Salis"

    ERIC Educational Resources Information Center

    Babovic, Vukota; Babovic, Miloš

    2014-01-01

    The history of science remembers more than just formal facts about scientific discoveries. These side stories are often inspiring. One of them, the story of an unfulfilled death wish of Jacob Bernoulli regarding spirals, inspired us to look around ourselves. And we saw natural spirals around us, which led to the creation of a Hooke's…

  2. Uncarinic acids: phospholipase Cgamma1 inhibitors from hooks of Uncaria rhynchophylla.

    PubMed

    Lee, J S; Yang, M Y; Yeo, H; Kim, J; Lee, H S; Ahn, J S

    1999-05-17

    Bioactivity-guided fractionation of the CHCl3 extract from hooks of Uncaria rhynchophylla led to the isolation of two triterpene esters, namely uncarinic acids A (1) and B (2). Their structures were established by spectroscopic and chemical methods. These compounds inhibited phospholipase Cgamma1 with IC50 values of 35.66 and 44.55 microM, respectively.

  3. Correcting the hooking effect in satellite altimetry data for time series estimation over smaller rivers

    NASA Astrophysics Data System (ADS)

    Boergens, Eva; Dettmering, Denise; Schwatke, Christian

    2015-04-01

    Since many years the numbers of in-situ gauging stations are declining. Satellite altimetry can be used as a gap-filler even over smaller inland waters like rivers. However, since altimetry measurements are not designed for inland water bodies a special data handling is necessary in order to estimate reliable water level heights over inland waters. We developed a new routine for estimating water level heights over smaller inland waters with satellite altimetry by correcting the hooking effect. The hooking effect occurs when the altimeter is not measuring in nadir before and after passing a water body due to the stronger reflectance of the water than the surrounding land surface. These off-nadir measurements, together with the motion of the satellite, lead to overlong ranges and heights declining in a parabolic shape. The vertex of this parabola is on the water surface. Therefore, by estimating the parabola we are able to determine the water level height without the need of any point over the water body itself. For estimating the parabola we only use selected measurements which are effected by the hooking effect. The applied search approach is based on the RANSAC algorithm (random sample consensus) which is a non-deterministic algorithm especially designed for finding geometric entities in point clouds with many outliers. With the hooking effect correction we are able to retrieve water level height time series from the Mekong River from Envisat and Saral/Altika high frequency data. It is possible to determine reliable time series even if the river has only a width of 500m or less. The expected annual variations are clearly depicted and the comparison of the time series with available in-situ gauging data shows a very good agreement.

  4. Altered intragenic DNA methylation of HOOK2 gene in adipose tissue from individuals with obesity and type 2 diabetes

    PubMed Central

    Fernández-Bayón, Gustavo; Morales-Sánchez, Paula; Sanz, Lourdes; Turienzo, Estrella; González, Juan José; Martinez-Faedo, Ceferino; Suarez-Gutiérrez, Lorena; Ares, Jessica; Díaz-Naya, Lucia; Martin-Nieto, Alicia; Fernández-Morera, Juan L.; Fraga, Mario F.

    2017-01-01

    Aims/Hypothesis Failure in glucose response to insulin is a common pathology associated with obesity. In this study, we analyzed the genome wide DNA methylation profile of visceral adipose tissue (VAT) samples in a population of individuals with obesity and assessed whether differential methylation profiles are associated with the presence of type 2 diabetes (T2D). Methods More than 485,000 CpG genome sites from VAT samples from women with obesity undergoing gastric bypass (n = 18), and classified as suffering from type 2 diabetes (T2D) or not (no type 2 diabetes, NT2D), were analyzed using DNA methylation arrays. Results We found significant differential methylation between T2D and NT2D samples in 24 CpGs that map with sixteen genes, one of which, HOOK2, demonstrated a significant correlation between differentially hypermethylated regions on the gene body and the presence of type 2 diabetes. This was validated by pyrosequencing in a population of 91 samples from both males and females with obesity. Furthermore, when these results were analyzed by gender, female T2D samples were found hypermethylated at the cg04657146-region and the cg 11738485-region of HOOK2 gene, whilst, interestingly, male samples were found hypomethylated in this latter region. Conclusion The differential methylation profile of the HOOK2 gene in individuals with T2D and obesity might be related to the attendant T2D, but further studies are required to identify the potential role of HOOK2 gene in T2D disease. The finding of gender differences in T2D methylation of HOOK2 also warrants further investigation. PMID:29228058

  5. Flow field and thermal characteristics induced by a rotationally oscillating heated flat plate

    NASA Astrophysics Data System (ADS)

    Koffi, Moise

    The objective of this dissertation is the study the flow and heat transfer in the vicinity of a rectangular flat heated plate of subject to rotational oscillations. Of interest is the effect of the flow field on the thermal characteristics of the plate's surface. A constant heat flux is applied to both sides while the plate is rotated about a fixed edge at a frequency of 2 rad/s in an infinite domain at atmospheric pressure. A computational simulation of the flow with FLUENT reveals a hooked-shape vortex tube around the free edges of the plate, which is confirmed by the flow visualization with smoke particles. During the flapping cycle, vortices form and grow progressively on one face while they shed from the opposite, until they are completely detached from both surfaces at stroke reversal. A data acquisition system uses a numerical computing and programming software (MATLAB) to track the surface temperature recorded by J- type thermocouples at desired locations on the plate. Both experimental and computational results agree with local surface temperature profiles characterized by a transient unsteady periodic variation followed by a steady periodic phase. These characteristics are symmetrical about the median plane of the plate, which is normal to its axis of rotation. The cooling rate of the surface, proportional to the frequency of rotation, depends on the angular position of the plate and the spatial location on the plate's surface. However, the highest heat transfer coefficient is recorded at free edges, especially in the corners swept by strong tip vortices shedding in two orthogonal directions. Conclusions of the present study are used to explain the role of ear flapping in the metabolic heat regulation of large mammals such as elephants. Flow visualization and surface temperature measurements of full size rigid and flexible elephant ear-shape models were carried out. Results indicate improved interaction between the shedding vortex and the model's boundary

  6. Four new glycosides from the stems of Dendrobium fimbriatum Hook.

    PubMed

    Xu, Feng-Qing; Fan, Wei-Wei; Zi, Cheng-Ting; Dong, Fa-Wu; Yang, Dan; Zhou, Jun; Hu, Jiang-Miao

    2017-04-01

    Four new glucosides, named as gigantol-5-O-β-d-glucopyranoside (1), 9,10-dihydro-aphyllone A-5-O-β-d-glucopyranoside (2), ficusal-4-O-β-d-glucopyranoside (3), botrydiol-15-O-β-d-glucopyranoside (4), together with eight known compounds (5-12) were isolated from the n-BuOH extract of the stems of Dendrobium fimbriatum Hook. Their structures were elucidated by the analyses of spectroscopic data.

  7. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    PubMed

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  8. Use of the chop hook to stabilize the capsular bag in patients with crystalline lens dislocations and cataracts.

    PubMed

    Zeng, Yanfeng; Fan, Licheng; Lu, Peirong

    2017-04-01

    Objective To observe the treatment effects of chop hook-assisted phacoemulsification surgery in patients with crystalline lens dislocation. Methods Thirty-seven eyes with cataracts and crystalline lens dislocations underwent cataract surgery. An L-shaped chop hook was introduced into the anterior chamber, and the tip was pushed or pulled to the centre of the anterior capsular edge of the zonular dialysis during the cataract operation. Postoperative follow-up was conducted for ≥ 1 month. Results All patients' postoperative visual abilities improved except one patient with glaucoma. One patient who underwent -5D intraocular lens implantation exhibited vision of 1/50. Visual acuity was less than 6/20 in 6 eyes, 6/20 to 10/20 in 7 eyes, and greater than 10/20 in 22 eyes. Conclusions L-shaped chop hooks can be used to push or pull the anterior capsular edge of the zonular dialysis for protection and avoidance of further zonular damage. This strategy provides satisfactory effects and reduces use of additional instruments.

  9. 33 CFR 165.130 - Sandy Hook Bay, New Jersey-security zone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-security zone. 165.130 Section 165.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Hook Bay, New Jersey—security zone. (a) Naval Ammunition Depot Piers. The navigable waters within the following boundaries are a security zone: A line beginning on the shore at 40°25′55.6″ N, 074°04′31.4″ W...

  10. 33 CFR 165.130 - Sandy Hook Bay, New Jersey-security zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-security zone. 165.130 Section 165.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Hook Bay, New Jersey—security zone. (a) Naval Ammunition Depot Piers. The navigable waters within the following boundaries are a security zone: A line beginning on the shore at 40°25′55.6″ N, 074°04′31.4″ W...

  11. 33 CFR 165.130 - Sandy Hook Bay, New Jersey-security zone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-security zone. 165.130 Section 165.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Hook Bay, New Jersey—security zone. (a) Naval Ammunition Depot Piers. The navigable waters within the following boundaries are a security zone: A line beginning on the shore at 40°25′55.6″ N, 074°04′31.4″ W...

  12. 33 CFR 165.130 - Sandy Hook Bay, New Jersey-security zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-security zone. 165.130 Section 165.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Hook Bay, New Jersey—security zone. (a) Naval Ammunition Depot Piers. The navigable waters within the following boundaries are a security zone: A line beginning on the shore at 40°25′55.6″ N, 074°04′31.4″ W...

  13. 33 CFR 165.130 - Sandy Hook Bay, New Jersey-security zone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-security zone. 165.130 Section 165.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Hook Bay, New Jersey—security zone. (a) Naval Ammunition Depot Piers. The navigable waters within the following boundaries are a security zone: A line beginning on the shore at 40°25′55.6″ N, 074°04′31.4″ W...

  14. 46 CFR 7.35 - Sandy Hook, NJ to Cape May, NJ.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Atlantic Coast § 7.35 Sandy Hook, NJ to Cape May, NJ. (a) A line drawn from Shark River Inlet North Breakwater Light “2” to Shark River Inlet South Breakwater Light “1”. (b) A line drawn from Manasquan Inlet... Absecon Inlet North Jetty to Atlantic City Light. (g) A line drawn from the southernmost point of Longport...

  15. Biomechanical Analysis of the Proximal Adjacent Segment after Multilevel Instrumentation of the Thoracic Spine: Do Hooks Ease the Transition?

    PubMed Central

    Metzger, Melodie F.; Robinson, Samuel T.; Svet, Mark T.; Liu, John C.; Acosta, Frank L.

    2015-01-01

    Study Design Biomechanical cadaveric study. Objective Clinical studies indicate that using less-rigid fixation techniques in place of the standard all-pedicle screw construct when correcting for scoliosis may reduce the incidence of proximal junctional kyphosis and improve patient outcomes. The purpose of this study is to investigate whether there is a biomechanical advantage to using supralaminar hooks in place of pedicle screws at the upper-instrumented vertebrae in a multilevel thoracic construct. Methods T7–T12 spines were biomechanically tested: (1) intact; (2) following a two-level pedicles screw fusion from T9 to T11; and after proximal extension of the fusion to T8–T9 with (3) bilateral supra-laminar hooks, (4) a unilateral hook + unilateral screw hybrid, or (5) bilateral pedicle screws. Specimens were nondestructively loaded while three-dimensional kinematics and intradiscal pressure at the supra-adjacent level were recorded. Results Supra-adjacent hypermobility was reduced when bilateral hooks were used in place of pedicle screws at the upper-instrumented level, with statistically significant differences in lateral bending and torsion (p < 0.05 and p < 0.001, respectively). Disk pressures in the supra-adjacent segment were not statistically different among top-off techniques. Conclusions The use of supralaminar hooks at the top of a multilevel posterior fusion construct reduces the stress at the proximal uninstrumented motion segment. Although further data is needed to provide a definitive link to the clinical occurrence of PJK, this in vitro study demonstrates the potential benefit of “easing” the transition between the stiff instrumented spine and the flexible native spine and is the first to demonstrate these results with laminar hooks. PMID:27190735

  16. Assessing College Students' Autonomy over Smoking with the Hooked on Nicotine Checklist

    ERIC Educational Resources Information Center

    Wellman, Robert; McMillen, Robert; DiFranza, Joseph

    2008-01-01

    Objective, Participants, and Methods: In this study, the authors explored the psychometric properties of the Hooked on Nicotine Checklist (HONC) among 300 college students who were current smokers. The HONC is a 10-item survey instrument designed to measure diminished autonomy over smoking, a key aspect of dependence. Autonomy is diminished when…

  17. Jurassic onychites (hooks from squid-like cephalopods) associated with statolith occurrences in the Wessex Basin, southern England

    NASA Astrophysics Data System (ADS)

    Hart, Malcolm; Page, Kevin; Price, Gregory; Smart, Christopher; Wilby, Philip

    2016-04-01

    Modern coleoid (squid-like) cephalopods have arms that carry arrays of both suckers and hardened, organic hooks. Fossil arm hooks have been known since the description of Sternberg in 1823, although he identified them as plant remains. During the twentieth century there were a number of brief descriptions of hooks but it was Kulicki & Szaniawski (1972) who described 22 morphotypes from the Jurassic of Poland. These authors gave these 'forms' names using a binomial classification though, with many lacking defined (and figured) holotypes and, in some cases, only one recorded specimen, some of their designations should be regarded as invalid. Some of the morphotypes have, however, been reported from DSDP sites on the Falkland Plateau as well as New Zealand, Germany, Poland and the United Kingdom. It is clear that the hooks must belong to widely distributed members of the Belemnitida and Phragmoteuthida. Exceptional soft-bodied preservation of species such as Belemnotheutis antiquus from the Callovian-Oxfordian of the United Kingdom has allowed the identification of the host animal of some morphotypes, though the majority remain non-attributable. In the Christian Malford lagerstätte (Upper Callovian) of Wiltshire large numbers of hooks (including forms described as Acanthuncus, Arites, Deinuncus, Falcuncus, Longuncus and Paraglycerites) are found associated with an abundance of statoliths (cephalopod 'ear bones') and macrofossil evidence of both belemnites and teuthids, some of which includes exceptional soft-bodied preservation (see Wilby et al., 2004, 2008; Hart et al., in press). Using the abundance of material available to us from the Wessex Basin, we are attempting to identify, where possible, the host animals. If this can be established then it should be possible, using micropalaeontological samples, to determine the stratigraphical and palaeoecological ranges of some of the host macro-fossils, many of which are otherwise rarely preserved. HART, M.B., DE JONGHE

  18. Hybrid constructs for tridimensional correction of the thoracic spine in adolescent idiopathic scoliosis: a comparative analysis of universal clamps versus hooks.

    PubMed

    Ilharreborde, Brice; Even, Julien; Lefevre, Yan; Fitoussi, Franck; Presedo, Ana; Penneçot, Georges-François; Mazda, Keyvan

    2010-02-01

    Retrospective study of prospectively collected data. Compare Universal Clamps (UCs) and hooks for the thoracic correction of adolescent idiopathic scoliosis (AIS). In scoliosis surgery, sagittal correction is as important as frontal correction due to the risk of junctional kyphosis. Compared to all-screw constructs, hybrid constructs with lumbar pedicle screws and thoracic hooks or sublaminar wires have been shown to achieve similar coronal correction while providing superior postoperative thoracic kyphosis. The authors used a novel sublaminar thoracic implant, the UC with improvements over sublaminar wires. Hybrid constructs using thoracic UCs were compared to those with thoracic hooks. This series involved 150 patients treated for AIS with hybrid constructs. A total of 75 consecutive patients operated from 2001 to 2003, who had thoracic hooks with in situ contouring, distraction, and compression (Group 1), were compared to 75 consecutive patients operated from 2004 to 2006, who had thoracic UCs with posteromedial translation (Group 2). All had intraoperative somatosensory/motor-evoked potential monitoring and at least 2-years follow-up. Except for follow-up (longer in Group 1), the 2 groups were similar before surgery. The UCs achieved better thoracic coronal correction (P < 0.001), Cincinnati index (P < 0.001), kyphosis (P = 0.02), and apical rotation (P < 0.001). In normokyphotic or hypokyphotic patients, the UC corrected thoracic kyphosis by 11.2 degrees (55%) versus 0.4 degrees (2%) achieved by hooks (P < 0.0001). These differences were stable at last follow-up. There were no intraoperative complications or changes in somatosensory/motor-evoked potentials. UC reduced operative time by 20% (60 minutes; P < 0.001) and blood loss by 23% (250 mL; P < 0.001). Although both of these hybrid constructs efficaciously corrected the coronal and axial deformities in AIS, the results of the UC technique were superior to those achieved with hooks in all 3 planes

  19. A novel mutation R190H in the AT-hook 1 domain of MeCP2 identified in an atypical Rett syndrome.

    PubMed

    Zhou, Xiao; Liao, Yuangao; Xu, Miaojing; Ji, Zhong; Xu, Yunqi; Zhou, Liang; Wei, Xiaoming; Hu, Peiqian; Han, Peng; Yang, Fanghan; Pan, Suyue; Hu, Yafang

    2017-10-10

    Mutations in Methyl-CpG binding protein 2 ( MECP2 ) have been identified as the disease-causing mutations in Rett Syndrome (RTT). However, no mutation in the AT-hook 1 domain of MECP2 has been reported in RTT yet. The function of AT-hook 1 domain of MECP2 has not been described either. The clinical and radiological features of a girl with progressive hyperactivity and loss of acquired linguistic and motor functions were presented. Next generation sequencing was used to screen the causative gene. Effect of the mutant protein on histone 3 methylation was assessed in vitro experiment. The patient was diagnosed with an atypical RTT at the age of nine. Magnetic resonance imaging revealed a loss of whole-brain volume and abnormal myelination. Genetic analysis identified a de novo novel missense mutation of MECP2 (NM_004992, c.570G->A, p.Arg190His). This mutation is located in the AT-hook 1 domain of MeCP2 protein. Overexpression of the mutant MeCP2 in cultured neuroblastoma cells SH-SY5Y revealed increased level of dimethylated histone 3 lysine 9, a transcriptional repressor marker. A novel missense mutation in AT-hook 1 domain of MeCP2 was identified in a patient with atypical RTT. Clinical data and in vitro experiment result imply that R190H mutation in AT-hook1 may cause dysfunction of MeCP2 and be a pathogenic variant.

  20. Visitor and community survey results for Prime Hook National Wildlife Refuge: Completion report

    USGS Publications Warehouse

    Sexton, Natalie R.; Stewart, Susan C.; Koontz, Lynne; Ponds, Phadrea; Walters, Katherine D.

    2007-01-01

    Community residents’ perceptions and opinions Data for this study were collected using a survey administered to visitors to Prime Hook NWR and individuals living in the communities surrounding the Refuge. Surveys were randomly distributed to both consumptive and nonconsumptive use visitors over a one year period (September 2004 to September 2005) to account for seasonal variation in Refuge use. Three hundred thirty-two visitor surveys were returned for a response rate of 80 percent with a confidence interval of ± 5.4. Surveys were also distributed to a stratified random sample of community members in adjacent and surrounding areas (Slaughter Beach, Broadkill Beach, Prime Hook Beach, Milton, Lewes, Milford, and surrounding communities). Four hundred ninety-one surveys from the overall community sample were returned for a response rate of 39 percent with a ± 4.4 confidence interval. Community member results were weighted by U.S. Census Bureau data to correct for age and gender bias, and for community proportionality.

  1. New realizations of 𝒩 = 2l-conformal Newton-Hooke superalgebra

    NASA Astrophysics Data System (ADS)

    Masterov, Ivan

    2015-04-01

    By applying Niederer-like transformation, we construct a representation of the 𝒩 = 2l-conformal Newton-Hooke (NH) superalgebra for the case of a negative cosmological constant in terms of linear differential operators as well as its dynamical realization. Another variant of 𝒩 = 2 supersymmetric Pais-Uhlenbeck oscillator for a particular choice of its frequencies is proposed. The advantages of such realizations as compared to their analogues introduced in [I. Masterov, J. Math. Phys.53, 072904 (2012)], are discussed.

  2. Spectroscopic Analyses of the "Blue Hook" Stars in Omega Centauri: A Test of the Late Hot Flasher Scenario

    NASA Technical Reports Server (NTRS)

    Moehler, S.; Sweigart, Allan V.; Landsman, W. B.; Dreizler, S.; Rabin, Douglas M. (Technical Monitor)

    2002-01-01

    (Omega) Cen contains the largest population of very hot horizontal branch (HB) stars known in a globular cluster. Recent UV observations (Whitney et al. 1998; D'Cruz et al. 2000) show a significant population of hot stars below the zero-age horizontal branch ("blue hook" stars), which cannot be explained by canonical stellar evolution. Stars which suffer unusually large mass loss on the red giant branch and thus experience the helium core flash while descending the white dwarf cooling curve could populate this region. Theory predicts that these "late hot flashers" should show higher temperatures than the hottest canonical HB stars and should have helium- and carbon-rich atmospheres. We obtained and analysed medium resolution spectra of a sample of blue hook stars to derive their atmospheric parameters. The blue hook stars are indeed both hotter (T(sub eff)>35,000 K) and more helium-rich than classical extreme HB stars. In addition we find indications for a large enhancement of the carbon abundance relative to the cluster abundance.

  3. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    PubMed Central

    Al-Sadek, Tabet A.; Niklev, Desislav; Al-Sadek, Ahmed

    2016-01-01

    BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with “Talwarkar” square nails

  4. Greenland shark (Somniosus microcephalus) feeding behavior on static fishing gear, effect of SMART (Selective Magnetic and Repellent-Treated) hook deterrent technology, and factors influencing entanglement in bottom longlines

    PubMed Central

    Sullivan, Rennie; Hedges, Kevin J.

    2018-01-01

    The Greenland Shark (Somniosus microcephalus) is the most common bycatch in the Greenland halibut (Reinhardtius hippoglossoides) bottom longline fishery in Cumberland Sound, Canada. Historically, this inshore fishery has been prosecuted through the ice during winter but winter storms and unpredictable landfast ice conditions since the mid-1990s have led to interest in developing a summer fishery during the ice-free season. However, bycatch of Greenland shark was found to increase substantially with 570 sharks captured during an experimental Greenland halibut summer fishery (i.e., mean of 6.3 sharks per 1,000 hooks set) and mortality was reported to be about 50% due in part to fishers killing sharks that were severely entangled in longline gear. This study investigated whether the SMART (Selective Magnetic and Repellent-Treated) hook technology is a practical deterrent to Greenland shark predation and subsequent bycatch on bottom longlines. Greenland shark feeding behavior, feeding kinematics, and variables affecting entanglement/disentanglement and release are also described. The SMART hook failed to deter Greenland shark predation, i.e., all sharks were captured on SMART hooks, some with more than one SMART hook in their jaw. Moreover, recently captured Greenland sharks did not exhibit a behavioral response to SMART hooks. In situ observations of Greenland shark feeding show that this species uses a powerful inertial suction mode of feeding and was able to draw bait into the mouth from a distance of 25–35 cm. This method of feeding is suggested to negate the potential deterrent effects of electropositive metal and magnetic alloy substitutions to the SMART hook technology. The number of hooks entangled by a Greenland shark and time to disentangle and live-release a shark was found to increase with body length. PMID:29785345

  5. Greenland shark (Somniosus microcephalus) feeding behavior on static fishing gear, effect of SMART (Selective Magnetic and Repellent-Treated) hook deterrent technology, and factors influencing entanglement in bottom longlines.

    PubMed

    Grant, Scott M; Sullivan, Rennie; Hedges, Kevin J

    2018-01-01

    The Greenland Shark ( Somniosus microcephalus ) is the most common bycatch in the Greenland halibut ( Reinhardtius hippoglossoides ) bottom longline fishery in Cumberland Sound, Canada. Historically, this inshore fishery has been prosecuted through the ice during winter but winter storms and unpredictable landfast ice conditions since the mid-1990s have led to interest in developing a summer fishery during the ice-free season. However, bycatch of Greenland shark was found to increase substantially with 570 sharks captured during an experimental Greenland halibut summer fishery (i.e., mean of 6.3 sharks per 1,000 hooks set) and mortality was reported to be about 50% due in part to fishers killing sharks that were severely entangled in longline gear. This study investigated whether the SMART (Selective Magnetic and Repellent-Treated) hook technology is a practical deterrent to Greenland shark predation and subsequent bycatch on bottom longlines. Greenland shark feeding behavior, feeding kinematics, and variables affecting entanglement/disentanglement and release are also described. The SMART hook failed to deter Greenland shark predation, i.e., all sharks were captured on SMART hooks, some with more than one SMART hook in their jaw. Moreover, recently captured Greenland sharks did not exhibit a behavioral response to SMART hooks. In situ observations of Greenland shark feeding show that this species uses a powerful inertial suction mode of feeding and was able to draw bait into the mouth from a distance of 25-35 cm. This method of feeding is suggested to negate the potential deterrent effects of electropositive metal and magnetic alloy substitutions to the SMART hook technology. The number of hooks entangled by a Greenland shark and time to disentangle and live-release a shark was found to increase with body length.

  6. Delaware River water quality Bristol to Marcus Hook, Pennsylvania, August 1949 to December 1963

    USGS Publications Warehouse

    Keighton, Walter B.

    1965-01-01

    During the 14-year period from August 1949 to July 1963, the U.S. Geological Survey, in cooperation with the city of Philadelphia, collected samples of river water once each month in the 43-mile reach of the Delaware River from Bristol to Marcus Hook, Pa., and daily at Trenton, 10 miles upstream from Bristol. This part of the Delaware is an estuary into which salt water is brought by tides; fresh water flows into the estuary at Trenton, NJ, and farther downstream from the Schuylkill River and other tributaries of the Delaware. In March, April, and May, when fresh-water flow is high, the average concentration of dissolved solids in the water at Bristol was 76 ppm (parts per million), and at Marcus Hook 112 PPM In August and September, streamflow is lower, and the average concentration of dissolved solids increased to 117 PPM at Bristol and 804 PPM at Marcus Hook. Major salinity invasions of the Delaware River occurred in 1949, 1953, 1954, 1957, and 1963. In each of these years the fresh-water flow into the tidal river at Trenton was low during the period from July to October. The greatest dissolved-solids concentrations in these monthly samples were 160 PPM at Bristol and 4,000 PPM at Marcus Hook. At times the dissolved-oxygen concentration of the river water has become dangerously low, especially in that reach of the river between Wharton Street and League Island. At the Benjamin Franklin Bridge, one-third of the samples of river water were less than 30 percent saturated with oxygen; however, no trend, either for better or for worse, was apparent during the 14-year period. It is useful now to summarize these monthly analyses for the period 1949-63 even though a much more detailed description of water quality in this reach of the estuary will soon become available through the use of recording instrumental conditions. This compendium of water-quality data is useful as an explicit statement of water quality during the 14-year study period and is valuable for directing

  7. Hooking tomorrow's geoscientists: Authentic field inquiry as a compelling pedagogy

    NASA Astrophysics Data System (ADS)

    Wallstrom, Erica

    2015-04-01

    Engaging high school students in the geosciences without providing them with opportunities to directly explore, understand, and question the natural world is like trying to catch a fish without a hook. How can educators hope to inspire youth to pursue a career in the geosciences when the subject is first introduced to teenagers within the confines of a classroom? Regardless of the content and activities employed by the teacher, the synthetic classroom setting is unable to recreate the organic richness of an authentic outdoor learning environment. A new course offering at Rutland High School in Rutland, Vermont, USA shifts away from the traditional classroom based pedagogy by focusing the learning on exploring the temporal changes occurring in the region's geologic features. Numerous visits to local quarries, outcrops, overlooks, and universities guide the course curriculum. Students use their new understandings and personal observations to complete a culminating independent investigation. This alternate learning model is made possible through collaboration with local universities, businesses, and government agencies. If the geosciences is to remain competitive in the recruitment of exemplary STEM candidates, than the focus of high school earth science programs must be considered. This course offers one alternative to improve engagement and understanding of the geoscience standards. While not the only option, it offers one possibility for hooking students on geosciences.

  8. Kohn's theorem, Larmor's equivalence principle and the Newton-Hooke group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibbons, G.W., E-mail: gwg1@amtp.cam.ac.uk; Pope, C.N.; George P. and Cynthia W. Mitchell Institute for Fundamental Physics and Astronomy, Texas A and M University, College Station, TX 77843-4242

    2011-07-15

    Highlights: > We show that non-relativistic electrons moving in a magnetic field with trapping potential admits as relativity group the Newton-Hooke group. > We use this fact to give a group theoretic interpretation of Kohn's theorem and to obtain the spectrum. > We obtain the lightlike lift of the system exhibiting showing it coincides with the Nappi-Witten spacetime. - Abstract: We consider non-relativistic electrons, each of the same charge to mass ratio, moving in an external magnetic field with an interaction potential depending only on the mutual separations, possibly confined by a harmonic trapping potential. We show that the systemmore » admits a 'relativity group' which is a one-parameter family of deformations of the standard Galilei group to the Newton-Hooke group which is a Wigner-Inoenue contraction of the de Sitter group. This allows a group-theoretic interpretation of Kohn's theorem and related results. Larmor's theorem is used to show that the one-parameter family of deformations are all isomorphic. We study the 'Eisenhart' or 'lightlike' lift of the system, exhibiting it as a pp-wave. In the planar case, the Eisenhart lift is the Brdicka-Eardley-Nappi-Witten pp-wave solution of Einstein-Maxwell theory, which may also be regarded as a bi-invariant metric on the Cangemi-Jackiw group.« less

  9. Retrospective Evaluation of Safety, Efficacy and Risk Factors for Pneumothorax in Simultaneous Localizations of Multiple Pulmonary Nodules Using Hook Wire System.

    PubMed

    Zhong, Yan; Xu, Xiao-Quan; Pan, Xiang-Long; Zhang, Wei; Xu, Hai; Yuan, Mei; Kong, Ling-Yan; Pu, Xue-Hui; Chen, Liang; Yu, Tong-Fu

    2017-09-01

    To evaluate the safety and efficacy of the hook wire system in the simultaneous localizations for multiple pulmonary nodules (PNs) before video-assisted thoracoscopic surgery (VATS), and to clarify the risk factors for pneumothorax associated with the localization procedure. Between January 2010 and February 2016, 67 patients (147 nodules, Group A) underwent simultaneous localizations for multiple PNs using a hook wire system. The demographic, localization procedure-related information and the occurrence rate of pneumothorax were assessed and compared with a control group (349 patients, 349 nodules, Group B). Multivariate logistic regression analyses were used to determine the risk factors for pneumothorax during the localization procedure. All the 147 nodules were successfully localized. Four (2.7%) hook wires dislodged before VATS procedure, but all these four lesions were successfully resected according to the insertion route of hook wire. Pathological diagnoses were acquired for all 147 nodules. Compared with Group B, Group A demonstrated significantly longer procedure time (p < 0.001) and higher occurrence rate of pneumothorax (p = 0.019). Multivariate logistic regression analysis indicated that position change during localization procedure (OR 2.675, p = 0.021) and the nodules located in the ipsilateral lung (OR 9.404, p < 0.001) were independent risk factors for pneumothorax. Simultaneous localizations for multiple PNs using a hook wire system before VATS procedure were safe and effective. Compared with localization for single PN, simultaneous localizations for multiple PNs were prone to the occurrence of pneumothorax. Position change during localization procedure and the nodules located in the ipsilateral lung were independent risk factors for pneumothorax.

  10. High-Dose Hook Effect in 17-Hydroxyprogesterone Assay in a Patient with 21-Hydroxylase Deficiency.

    PubMed

    Parlak, Mesut; Ellidağ, Hamit Yaşar; Türkkahraman, Doğa

    2015-12-01

    Congenital adrenal hyperplasia (CAH) describes a group of disorders characterized by enzyme defects in adrenal steroidogenesis. 21-hydroxylase deficiency (21-OHD) is the most commonly encountered form. The analysis of steroids in pediatric cases requires high-sensitivity assays. A 14-year-old Syrian girl was referred for evaluation of short stature, amenorrhea, and hirsutism. On physical examination, breast development was Tanner stage 1. She had a phallic clitoris with a single urogenital orifice. Laboratory findings revealed primary adrenal deficiency with high androgen levels and low levels of 17-hydroxyprogesterone (17-OHP), (<0.05 ng/mL) and estrogen. This unexpected result led to suspicion of a high-dose hook effect. The measurement was repeated after 1/10 dilution of serum, and a high level of 17-OHP (115.4 ng/mL) was detected with the same test-enzyme-linked immunosorbent assay (ELISA). Simple virilizing form of CAH (21-OHD) was suspected and confirmed with genetic analysis. After initiation of glucocorticoid therapy, breast development was noted along with a decrease in testosterone level and an increase in estrogen level. To our knowledge, this is the first case report of hook effect for 17-OHP immunoassay in a patient with 21-OHD. High-dose hook effect should be suspected in patients with CAH when the test results are incompatible with one another. Additionally, this case demonstrates that a high testosterone level can block aromatase activity and consequently also estrogen production and breast development.

  11. Stabilization of Volar Ulnar Rim Fractures of the Distal Radius: Current Techniques and Review of the Literature

    PubMed Central

    O'Shaughnessy, Maureen A.; Shin, Alexander Y.; Kakar, Sanjeev

    2016-01-01

    Background Distal radius fractures involving the lunate facet can be challenging to manage. Reports have shown the volar carpal subluxation/dislocation that can occur if the facet is not appropriately stabilized. Literature Review Recent emphasis in the literature has underscored the difficulty in managing this fracture fragment, suggesting standard volar plates may not be able to adequately stabilize the fragment. This article reviews the current literature with a special emphasis on fixation with a specifically designed fragment-specific hook plate to secure the lunate facet. Case Description An extended flexor carpi radialis volar approach was made which allows access to the distal volar ulnar fracture fragment. Once provisionally stabilized with Kirschner wire fixation, a volar hook plate was applied to capture this fragment. Additional fracture stabilization was used as deemed necessary to stabilize the remaining distal radius fracture. Clinical Relevance The volar marginal rim fragment remains a challenge in distal radius fracture management. Use of a hook plate to address the volar ulnar corner allows for stable fixation without loss of reduction at intermediate-term follow-up. PMID:27104076

  12. Entrapment of metal clusters in metal-organic framework channels by extended hooks anchored at open metal sites.

    PubMed

    Zheng, Shou-Tian; Zhao, Xiang; Lau, Samuel; Fuhr, Addis; Feng, Pingyun; Bu, Xianhui

    2013-07-17

    Reported here are the new concept of utilizing open metal sites (OMSs) for architectural pore design and its practical implementation. Specifically, it is shown here that OMSs can be used to run extended hooks (isonicotinates in this work) from the framework walls to the channel centers to effect the capture of single metal ions or clusters, with the concurrent partitioning of the large channel spaces into multiple domains, alteration of the host-guest charge relationship and associated guest-exchange properties, and transfer of OMSs from the walls to the channel centers. The concept of the extended hook, demonstrated here in the multicomponent dual-metal and dual-ligand system, should be generally applicable to a range of framework types.

  13. Firearms and accidental deaths: Evidence from the aftermath of the Sandy Hook school shooting.

    PubMed

    Levine, Phillip B; McKnight, Robin

    2017-12-08

    Exposure to firearms increased substantially after the December 2012 shooting at Sandy Hook Elementary School in Newtown, Connecticut, where 20 children and 6 adults were killed. Gun sales spiked by 3 million, on the basis of the increase in the number of background checks for firearm purchases. Google searches for buying and cleaning guns increased. We used Vital Statistics mortality data to examine whether a spike in accidental firearm deaths occurred at the same time as the greater exposure to firearms. We also assessed whether the increase in these deaths was larger in those states where the spike in gun sales per capita was larger. We find that an additional 60 deaths overall, including 20 children, resulted from unintentional shootings in the immediate aftermath of Sandy Hook. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  14. High-dose HOOK effect in urinary DcR2 assay in patients with chronic kidney disease.

    PubMed

    Chen, Jia; Chen, Ke-Hong; Wang, Li-Ming; Zhang, Wei-Wei; Feng, Lei; Dai, Huan-Zi; He, Ya-Ni

    2018-06-05

    Urinary DcR2 (uDcR2) is a biomarker for the early detection the tubulointerstitial injury (TII) in patients with chronic kidney disease (CKD), but the high-dose hook effect may lead to falsely low or even negative results when using an enzyme-linked immunosorbent assay (ELISA). This study aimed to investigate if the high-dose hook effect exists with ELISA testing, and to uncover a potential approach for reducing this effect. 72 CKD patients were recruited and categorized into four groups based on TII scores. uDcR2 was measured in undiluted and serially diluted (two-, four-, eight- and 16-fold dilutions) urine using an ELISA kit. The results from the assay were normalized to urinary creatinine. We evaluated the correlation between uDcR2/cre levels at different dilutions and renal histological parameters. Receiver operating characteristic (ROC) curves were generated to examine the value of uDcR2/cre for predicting TII. uDcR2/cre levels in the undiluted urine were significantly higher in patients with CKD than those in the control. However, higher TII scores did not yield higher levels of uDcR2/cre in the undiluted urine. After serial dilution, uDcR2/cre levels were highest with the four-fold dilution. A positive correlation was found between uDcR2/cre levels at different dilutions and TII scores, with the highest correlation coefficient and the largest AUC being observed at the four-fold dilution. The high-dose hook effect was apparent during ELISA testing of uDcR2 in CKD patients, yet dilution of the urine samples neutralized this effect. However, the use of a four-fold dilution of urine for uDcR2/cre testing may eliminate the high-dose hook effect and make it possible to effectively monitor the severity of TII in CKD patients. Copyright © 2018. Published by Elsevier Inc.

  15. Symposium of Hope: Recovery and Resiliency after the Sandy Hook Tragedy. Crisis Management

    ERIC Educational Resources Information Center

    Zenere, Frank J.

    2013-01-01

    On February 27 and 28, 2013, The Symposium of Hope: Recovery and Resilience after the Sandy Hook Tragedy, was held in Danbury, Connecticut. The event was hosted by the United Way of Western Connecticut and Western Connecticut State University. Frank J. Zenere, school psychologist and crisis team member in the Division of Student Services of the…

  16. The Sandy Hook Elementary School shooting as tipping point: "This Time Is Different".

    PubMed

    Shultz, James M; Muschert, Glenn W; Dingwall, Alison; Cohen, Alyssa M

    2013-01-01

    Among rampage shooting massacres, the Sandy Hook Elementary School shooting on December 14, 2012 galvanized public attention. In this Commentary we examine the features of this episode of gun violence that has sparked strong reactions and energized discourse that may ultimately lead toward constructive solutions to diminish high rates of firearm deaths and injuries in the United States.

  17. 46 CFR 160.170-17 - Marking and labeling.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....170-17 Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or... mechanism. (b) The plate or label must be in English, but may also be in other languages. (c) The plate or...

  18. 46 CFR 160.133-17 - Marking and labeling.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or label...) The plate or label must be in English, but may also be in other languages. (c) The plate or label must...

  19. 46 CFR 160.133-17 - Marking and labeling.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....133-17 Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or... mechanism. (b) The plate or label must be in English, but may also be in other languages. (c) The plate or...

  20. 46 CFR 160.133-17 - Marking and labeling.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....133-17 Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or... mechanism. (b) The plate or label must be in English, but may also be in other languages. (c) The plate or...

  1. 46 CFR 160.170-17 - Marking and labeling.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....170-17 Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or... mechanism. (b) The plate or label must be in English, but may also be in other languages. (c) The plate or...

  2. 46 CFR 160.170-17 - Marking and labeling.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....170-17 Marking and labeling. (a) Each hook body of a release mechanism must be marked with a plate or... mechanism. (b) The plate or label must be in English, but may also be in other languages. (c) The plate or...

  3. Latitude Hooks and Azimuth Kings: How To Build and Use 18 Traditional Navigational Tools.

    ERIC Educational Resources Information Center

    Fisher, Dennis

    This book contains directions for building and using 18 different traditional navigational tools. Each of the devices discussed has at one time or another been used for the practical business of navigation. Devices featured in this book include the Latitude Hook, Kamal, Astrolabe, Quadrant, Astronomical Ring, Sundial, Nocturnal, Cross Staff,…

  4. [Margaret Cavendish vs Robert Hooke: An impossible duel].

    PubMed

    Aït-Touati, Frédérique

    2016-12-01

    In 1665, Robert Hooke published his major work in microscopy, Micrographia, a defense of experimental philosophy. The following year, Margaret Cavendish, Duchess of Newcastle, published at her own expense a treatise and a novel that undermined the basis of this new science. The dispute broke out at the initiative of the Duchess, in the context of a vast controversy about the legitimacy and the efficiency of optical instruments in natural philosophy. All the figures of the dual are used, except one: the counterattack. Cavendish, indeed, was alone on the battlefield. Is it possible to call a dual a battle with only one combatant? This particular case of dispute that stops owing to the shortage of combatants is the subject of this article.

  5. Defining the Hook Region Anatomy of the Guinea Pig Cochlea for Modeling of Inner Ear Surgery.

    PubMed

    Lo, Jonathon; Sale, Phillip; Wijewickrema, Sudanthi; Campbell, Luke; Eastwood, Hayden; O'leary, Stephen John

    2017-07-01

    The aim of this study was to describe the hook region anatomy of the guinea pig cochlea to identify the optimal surgical approach for cochlear implantation and to determine what anatomical structures are at risk. Animal studies investigating hearing loss after cochlear implantation surgery are currently constrained by the lack of a reproducible implantation model. Guinea pig cochleae were imaged using thin-sheet laser imaging microscopy. Images were stitched, reconstructed, and segmented for analysis. Insertion vectors were determined by tracing their paths to the outer wall and converting to Cartesian coordinates. Spherical surface and multiplane views were generated to analyze outer wall and radial forces of the insertion vector. Thin-sheet laser imaging microscopy enabled quantitative, whole specimen analysis of the soft and bony tissue relationships of the complex cochlear hook region in any desired plane without loss of image quality. Round window or cochleostomy approaches in the anteroinferior plane avoided direct damage to cochlear structures. Cochleostomy approach had large interindividual variability of angular depth and outer wall forces but predictable radial force. The guinea pig hook region and lower basal turn have similar structural relationships to humans. Careful cochleostomy placement is essentially for minimizing cochlear trauma and for ensuring a straight insertion vector that successfully advances around the outer wall. Experiments with guinea pigs that control for the surgical approach are likely to provide useful insights into the aetiology and the development of therapies directed at postimplantation hearing loss.

  6. Estimating reef fish discard mortality using surface and bottom tagging: effects of hook injury and barotrauma

    USGS Publications Warehouse

    Rudershausen, Paul J.; Buckel, Jeffrey A.; Hightower, Joseph E.

    2013-01-01

    We estimated survival rates of discarded black sea bass (Centropristis striata) in various release conditions using tag–recapture data. Fish were captured with traps and hook and line from waters 29–34 m deep off coastal North Carolina, USA, marked with internal anchor tags, and observed for release condition. Fish tagged on the bottom using SCUBA served as a control group. Relative return rates for trap-caught fish released at the surface versus bottom provided an estimated survival rate of 0.87 (95% credible interval 0.67–1.18) for surface-released fish. Adjusted for results from the underwater tagging experiment, fish with evidence of external barotrauma had a median survival rate of 0.91 (0.69–1.26) compared with 0.36 (0.17–0.67) for fish with hook trauma and 0.16 (0.08–0.30) for floating or presumably dead fish. Applying these condition-specific estimates of survival to non-tagging fishery data, we estimated a discard survival rate of 0.81 (0.62–1.11) for 11 hook and line data sets from waters 20–35 m deep and 0.86 (0.67–1.17) for 10 trap data sets from waters 11–29 m deep. The tag-return approach using a control group with no fishery-associated trauma represents a method to accurately estimate absolute discard survival of physoclistous reef species.

  7. Electron correlation in Hooke's law atom in the high-density limit.

    PubMed

    Gill, P M W; O'Neill, D P

    2005-03-01

    Closed-form expressions for the first three terms in the perturbation expansion of the exact energy and Hartree-Fock energy of the lowest singlet and triplet states of the Hooke's law atom are found. These yield elementary formulas for the exact correlation energies (-49.7028 and -5.807 65 mE(h)) of the two states in the high-density limit and lead to a pair of necessary conditions on the exact correlation kernel G(w) in Hartree-Fock-Wigner theory.

  8. A new orthodontic force system for moment control utilizing the flexibility of common wires: Evaluation of the effect of contractile force and hook length.

    PubMed

    Lai, Wei-Jen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro

    2018-01-01

    The application of an appropriate force system is indispensable for successful orthodontic treatments. Second-order moment control is especially important in many clinical situations, so we developed a new force system composed of a straight orthodontic wire and two crimpable hooks of different lengths to produce the second-order moment. The objective of this study was to evaluate this new force system and determine an optimum condition that could be used in clinics. We built a premolar extraction model with two teeth according to the concept of a modified orthodontic simulator. This system was activated by applying contractile force from two hooks that generated second-order moment and force. The experimental device incorporated two sensors, and forces and moments were measured along six axes. We changed the contractile force and hook length to elucidate their effects. Three types of commercial wires were tested. The second-order moment was greater on the longer hook side of the model. Vertical force balanced the difference in moments between the two teeth. Greater contractile force generated a greater second-order moment, which reached a limit of 150 g. Excessive contractile force induced more undesired reactions in the other direction. Longer hooks induced greater moment generation, reaching their limit at 10 mm in length. The system acted similar to an off-center V-bend and can be applied in clinical practice as an unconventional loop design. We suggest that this force system has the potential for second-order moment control in clinical applications. Copyright © 2017. Published by Elsevier B.V.

  9. MotD of Sinorhizobium meliloti and Related α-Proteobacteria Is the Flagellar-Hook-Length Regulator and Therefore Reassigned as FliK

    PubMed Central

    Eggenhofer, Elke; Rachel, Reinhard; Haslbeck, Martin; Scharf, Birgit

    2006-01-01

    The flagella of the soil bacterium Sinorhizobium meliloti differ from the enterobacterial paradigm in the complex filament structure and modulation of the flagellar rotary speed. The mode of motility control in S. meliloti has a molecular corollary in two novel periplasmic motility proteins, MotC and MotE, that are present in addition to the ubiquitous MotA/MotB energizing proton channel. A fifth motility gene is located in the mot operon downstream of the motB and motC genes. Its gene product was originally designated MotD, a cytoplasmic motility protein having an unknown function. We report here reassignment of MotD as FliK, the regulator of flagellar hook length. The FliK gene is one of the few flagellar genes not annotated in the contiguous flagellar regulon of S. meliloti. Characteristic for its class, the 475-residue FliK protein contains a conserved, compactly folded Flg hook domain in its carboxy-terminal region. Deletion of fliK leads to formation of prolonged flagellar hooks (polyhooks) with missing filament structures. Extragenic suppressor mutations all mapped in the cytoplasmic region of the transmembrane export protein FlhB and restored assembly of a flagellar filament, and thus motility, in the presence of polyhooks. The structural properties of FliK are consistent with its function as a substrate specificity switch of the flagellar export apparatus for switching from rod/hook-type substrates to filament-type substrates. PMID:16513744

  10. Initial characterization of the FlgE hook high molecular weight complex of Borrelia burgdorferi.

    PubMed

    Miller, Kelly A; Motaleb, Md A; Liu, Jun; Hu, Bo; Caimano, Melissa J; Miller, Michael R; Charon, Nyles W

    2014-01-01

    The spirochete periplasmic flagellum has many unique attributes. One unusual characteristic is the flagellar hook. This structure serves as a universal joint coupling rotation of the membrane-bound motor to the flagellar filament. The hook is comprised of about 120 FlgE monomers, and in most bacteria these structures readily dissociate to monomers (∼ 50 kDa) when treated with heat and detergent. However, in spirochetes the FlgE monomers form a large mass of over 250 kDa [referred to as a high molecular weight complex (HMWC)] that is stable to these and other denaturing conditions. In this communication, we examined specific aspects with respect to the formation and structure of this complex. We found that the Lyme disease spirochete Borrelia burgdorferi synthesized the HMWC throughout the in vitro growth cycle, and also in vivo when implanted in dialysis membrane chambers in rats. The HMWC was stable to formic acid, which supports the concept that the stability of the HMWC is dependent on covalent cross-linking of individual FlgE subunits. Mass spectrometry analysis of the HMWC from both wild type periplasmic flagella and polyhooks from a newly constructed ΔfliK mutant indicated that other proteins besides FlgE were not covalently joined to the complex, and that FlgE was the sole component of the complex. In addition, mass spectrometry analysis also indicated that the HMWC was composed of a polymer of the FlgE protein with both the N- and C-terminal regions remaining intact. These initial studies set the stage for a detailed characterization of the HMWC. Covalent cross-linking of FlgE with the accompanying formation of the HMWC we propose strengthens the hook structure for optimal spirochete motility.

  11. Initial Characterization of the FlgE Hook High Molecular Weight Complex of Borrelia burgdorferi

    PubMed Central

    Miller, Kelly A.; Motaleb, Md. A.; Liu, Jun; Hu, Bo; Caimano, Melissa J.; Miller, Michael R.; Charon, Nyles W.

    2014-01-01

    The spirochete periplasmic flagellum has many unique attributes. One unusual characteristic is the flagellar hook. This structure serves as a universal joint coupling rotation of the membrane-bound motor to the flagellar filament. The hook is comprised of about 120 FlgE monomers, and in most bacteria these structures readily dissociate to monomers (∼ 50 kDa) when treated with heat and detergent. However, in spirochetes the FlgE monomers form a large mass of over 250 kDa [referred to as a high molecular weight complex (HMWC)] that is stable to these and other denaturing conditions. In this communication, we examined specific aspects with respect to the formation and structure of this complex. We found that the Lyme disease spirochete Borrelia burgdorferi synthesized the HMWC throughout the in vitro growth cycle, and also in vivo when implanted in dialysis membrane chambers in rats. The HMWC was stable to formic acid, which supports the concept that the stability of the HMWC is dependent on covalent cross-linking of individual FlgE subunits. Mass spectrometry analysis of the HMWC from both wild type periplasmic flagella and polyhooks from a newly constructed ΔfliK mutant indicated that other proteins besides FlgE were not covalently joined to the complex, and that FlgE was the sole component of the complex. In addition, mass spectrometry analysis also indicated that the HMWC was composed of a polymer of the FlgE protein with both the N- and C-terminal regions remaining intact. These initial studies set the stage for a detailed characterization of the HMWC. Covalent cross-linking of FlgE with the accompanying formation of the HMWC we propose strengthens the hook structure for optimal spirochete motility. PMID:24859001

  12. 78 FR 58518 - Notification of Proposed Production Activity; Benteler Automotive Corporation (Automotive...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    .... On its domestic sales, Benteler would be able to choose the duty rate during customs entry procedures...: Metal stampings (crash cans, reinforcement plates, flange plates); bumper beams; toe hooks; cross member shells; side tubes; steel blanks; brackets; gussets; closing plates; castings of aluminum; flat-rolled...

  13. Gateway National Recreational Area - Sandy Hook Unit : automated fee entrance plaza and intelligent transportation system technical requirements

    DOT National Transportation Integrated Search

    2009-01-01

    The Volpe National Transportation Systems Center (Volpe Center) is providing technical : support to Sandy Hook, a unit of the Gateway National Recreation Area, in the planning and : concept development for possible Intelligent Transportation Systems ...

  14. Chemical characteristics of Delaware River water, Trenton, New Jersey, to Marcus Hook, Pennsylvania

    USGS Publications Warehouse

    Durfor, Charles N.; Keighton, Walter B.

    1954-01-01

    This progress report gives the results of an investigation of the quality of water in the Delaware River from Trenton, N. J. to Marcus Hook, Pa., for the period August 1949 to December 1952. The Delaware River is the principal source of water for the many industries and municipal water supplies along this reach of the river and both industries and municipalities use it for the disposal of their wastes. Consequently, a study of the quality of the water and variations in the quality caused by changes in streamflow, tidal effects, pollution and other factors is important to the many users. In both New Jersey and Pennsylvania steps are being taken to abate pollution, thus it is of more than passing interest to measure the effects of waste treatment on the quality of the Delaware River water. At average or higher rates of streamflow the mineral content of the water increases slightly from Trenton to Marcus Hook. There is little variation in the concentration of dissolved minerals from bank to bank or from top to bottom of the river. At times of protracted low rates of flow the effect of ocean water mixing with the river water may be noted as far upstream as Philadelphia. At such times the salinity is often greater near the bottom of the river than near the top. The increase in chloride concentration upstream from Philadelphia is small compared to the rapid increase downstream from Philadelphia. Temperatures of offshore water vary with the season, but on a given day are substantially uniform throughout the reach of the river from Trenton to Marcus Hook. The water contains less dissolved oxygen as it flows downstream indicating that oxygen is being consumed by oxidizable matter. From Philadelphia downstream there are periods, especially in late summer, when the dissolved oxygen is barely sufficient to meet the oxygen demands of the pollution load.

  15. Hydrodynamics of a flexible plate between pitching rigid plates

    NASA Astrophysics Data System (ADS)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  16. Using a bioenergetic model to assess growth reduction from catch-and-release fishing and hooking injury in rainbow trout, Oncorhynchus mykiss

    USGS Publications Warehouse

    Meka, Julie M.; Margraf, F.J.

    2007-01-01

    A bioenergetic model was used to predict the potential effects of feeding cessation caused by catch-and-release capture and a reduction in feeding efficiency from hooking injuries on rainbow trout, Oncorhynchus mykiss (Walbaum), growth in southwest Alaska, USA. Simulations indicated that a 1-day feeding cessation for a rainbow trout captured one to two times during summer months resulted in deviations from expected growth of −3% to −15%. To represent debilitating hooking injuries, the proportion of the maximum feeding potential was decreased by 5–50% resulting in deviations from expected growth of −9% to −164%. Simulated growth effects were most prominent from captures during months when salmon eggs and flesh constituted the majority of the trout diet. Simulated growth effects from reduced foraging efficiency were most prominent when hooking injuries occurred early in the fishing season. These simulations suggest that rainbow trout are most vulnerable to decreases in growth when salmon are abundant and spawning and, coincidentally, during the months when most fishing occurs.

  17. Stress induced by hooking, net towing, elevated sea water temperature and air in sablefish: Lack of concordance between mortality and physiological measures of stress

    USGS Publications Warehouse

    Davis, M.W.; Olla, B.L.; Schreck, C.B.

    2001-01-01

    In a series of laboratory studies designed to simulate bycatch processes, sablefish Anoplopoma fimbria were either hooked for up to 24 h or towed in a net for 4 h and then subjected to an abrupt transfer to elevated sea water temperature and air. Mortality did not result from hooking or net towing followed by exposure to air, but increased for both capture methods as fish were exposed to elevated temperatures, reflecting the magnifying effect of elevated temperature on mortality. Hooking and exposure to air resulted in increased plasma cortisol and lactate concentrations, while the combination of hooking and exposure to elevated temperature and air resulted in increased lactate and potassium concentrations. In fish that were towed in a net and exposed to air, cortisol, lactate, potassium and sodium concentrations increased, but when subjected to elevated temperature and air, no further increases occurred above the concentrations induced by net towing and air, suggesting a possible maximum of the physiological stress response. The results suggest that caution should be exercised when using physiological measures to quantify stress induced by capture and exposure to elevated temperature and air, that ultimately result in mortality, since the connections between physiological stress and mortality in bycatch processes remain to be fully understood.

  18. CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Matsui, Yusuke; Miyoshi, Shinichiro; Kanazawa, Susumu

    2016-01-01

    To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P =0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. Complications are usually minor and asymptomatic. A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.

  19. Content Analysis of Select YouTube Postings: Comparisons of Reactions to the Sandy Hook and Aurora Shootings and Hurricane Sandy.

    PubMed

    Miller, Eric D

    2015-11-01

    This study details an innovative and methodical content analysis of 2,207 YouTube comments from four different YouTube videos (e.g., breaking news or memorials) related to the 2012 Sandy Hook Elementary School and Aurora theater mass shootings and the catastrophic Hurricane Sandy. As expected, YouTube comments associated with the Sandy Hook shootings (particularly those from a memorial video) were especially likely to feature compassion and grief with lessened hostility. This study highlights differing online contexts by which individuals show grief and related emotions following man-made and natural calamities and how-even in an online environment-powerful situational contexts greatly guide behavior.

  20. Risk factors and consequences of unwanted sex among university students: hooking up, alcohol, and stress response.

    PubMed

    Flack, William F; Daubman, Kimberly A; Caron, Marcia L; Asadorian, Jenica A; D'Aureli, Nicole R; Gigliotti, Shannon N; Hall, Anna T; Kiser, Sarah; Stine, Erin R

    2007-02-01

    This is the first study of unwanted sexual experiences in the collegiate "hooking-up" culture. In a representative sample of 178 students at a small liberal arts university. Twenty-three percent of women and 7% of men surveyed reported one or more experiences of unwanted sexual intercourse. Seventy-eight percent of unwanted vaginal, anal, and oral incidents took place while--"hooking up,"--whereas 78% of unwanted fondling incidents occurred at parties or bars. The most frequently endorsed reason for unwanted sexual intercourse was impaired judgment due to alcohol. The most frequently endorsed reason for unwanted fondling was that it happened before the perpetrator could be stopped. Of those affected by unwanted sexual intercourse or unwanted fondling, 46.7% and 19.2% reported unwanted memories, 50% and 32.7% reported avoidance and numbing responses, and 30% and 26.9% reported hyperarousal responses, respectively. A preliminary model of unwanted sex and collegiate social dynamics is proposed to provide a heuristic for further research.

  1. A method to solubilise protein aggregates for immunoassay quantification which overcomes the neurofilament "hook" effect.

    PubMed

    Lu, Ching-Hua; Kalmar, Bernadett; Malaspina, Andrea; Greensmith, Linda; Petzold, Axel

    2011-02-15

    Neurofilament (Nf) aggregates are a common pathological feature of neurodegenerative disorders. Although Nf levels have been investigated as a potential disease biomarker, Nf aggregates may mask Nf epitopes, preventing accurate quantification by immunoassay. Using the SOD1(G93A) mouse model of amyotrophic lateral sclerosis, we developed a method to disrupt Nf aggregates, allowing optimal immunoassay performance. Phosphorylated (NfH(SMI35)) and hyperphosphorylated (NfH(SMI34)) Nf levels in plasma from 120-day SOD1(G93A) mice were quantified using an in-house ELISA modified for use with small volumes. Different pre-analytical methods were tested for their ability to solubilize Nf aggregates and immunoblotting was used for qualitative analysis. A 'hook effect' was observed for serially diluted plasma samples quantified using an ELISA originally developed for CSF samples. Immunoblotting confirmed the existence of high molecular-weight NfH aggregates in plasma and the resolving effect of timed urea on these aggregates. Thermostatic (pre-thawing) and chemical (calcium chelators, urea) pre-analytical processing of samples had variable success in disrupting NfH aggregates. Timed urea-calcium chelator incubation yielded the most consistent plasma NfH levels. A one hour sample pre-incubation with 0.5M urea in Barbitone-EDTA buffer at room temperature resolved the "hook effect" without compromising the ELISA. In SOD1(G93A) mice, median levels of NfH(SMI34) were over 10-fold and NfH(SMI35) levels 5-fold greater than controls. NfH aggregates can be solubilised and the "hook effect" abolished by a one-hour sample pre-incubation in a urea-calcium chelator-enriched buffer. This method is applicable for quantification of NfH phosphoforms in experimental and disease settings where Nf aggregate formation occurs. © 2010 Elsevier B.V. All rights reserved.

  2. Hooke's Law and the Stiffness of a Plastic Spoon

    NASA Astrophysics Data System (ADS)

    Pestka, Kenneth A.; Warren, Cori

    2012-11-01

    The study of elastic properties of solids is essential to both physics and engineering. Finding simple, easy-to-visualize examples to demonstrate these concepts is often difficult. In a previous article written by one of us (KAPII), a simple method for determining Youngs modulus using marshmallows was given. In this article we will illustrate another method to explore elastic properties of everyday materials. This experiment uses a common plastic spoon exposed to a transverse force in order to determine the stiffness constant, yield point, and rupture point of the plastic spoon. In addition, much like the "Youngs Modulus of a Marshmallow" activity, this experiment visually demonstrates Hooke's law, is fun and easy to perform, and leaves a lasting impression on the students.

  3. Apical root resorption in maxillary incisors when employing micro-implant and J-hook headgear anchorage: a 4-month radiographic study.

    PubMed

    Wang, Qingzhu; Chen, Wenjing; Smales, Roger J; Peng, Hui; Hu, Xiaokun; Yin, Lu

    2012-10-01

    This study evaluated, over a 4-month study period, the amount of apical root resorption occurring in maxillary central incisors following their retraction when employing either micro-implant or J-hook headgear anchorage. The prospective randomised clinical trial was conducted in Orthodontic Clinic, College of Stomatology, China from 2008-2009. Subjects are patients requiring fixed appliances on waiting list (n=20). In female Han Chinese patients aged from 16-26 years, standardized periapical radiographs from 10 randomly assigned patients with maxillary protrusions comprising the micro-implant group, and from 10 similar patients comprising the J-hook headgear group, were assessed for maxillary central incisor apical root resorption. Measurements before and after orthodontic therapy were also obtained from lateral cephalometric radiographs to calculate incisor horizontal retraction and vertical intrusion distances. Estimated retraction force vectors were calculated in horizontal and vertical directions for both treatment groups. Data analysis employed t-tests and the Pearson correlation test, with α=0.05 for statistical significance. The results showed that when compared with the J-hook group, significantly more apical root resorption shortening of the maxillary central incisors was observed in the micro-implant group (1.27 mm difference, 95% CI=0.70-1.84, P<0.001), which was associated with a significantly larger retraction distance (P=0.004) and a smaller vertical force component (P<0.0001). We are led to conclude that continuous activation of the nickel-titanium coil springs used in the micro-implant group resulted in significantly more apical root resorption shortening and maxillary central incisor retraction than when intermittent J-hook retraction was employed. The employment of continuous duration orthodontic forces presents a risk for increased apical root resorption that requires careful radiographic monitoring.

  4. Astronaut Jack Lousma hooks up cable for rate gyro six pack during EVA

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Jack R. Lousma, Skylab 3 pilot, hooks up a 23 ft. 2 in. connecting cable for the rate gyro six pack during extravehicular activity (EVA) on August 24, 1973, as senn in this photographic reproduction taken from a color television tranmsission made by a TV camera aboard the Skylab space station in Earth orbit. The rate gyros were mounted inside the Multiple Docking Adapter opposite the Apollo Telescope Mount control and display console.

  5. Hooking up in Young Adulthood: A Review of Factors Influencing the Sexual Behavior of College Students

    ERIC Educational Resources Information Center

    Stinson, Rebecca D.

    2010-01-01

    Hooking up, or casual "no strings attached" sexual encounters, has become the normative heterosexual relationship on college campuses. This phenomenon has only recently received public attention. Many citizens have become alarmed that this trend is indicative of moral decline in our culture, a reflection of our hypersexualized media, and a…

  6. 78 FR 60018 - Requested Administrative Waiver of the Coastwise Trade Laws: Vessel HOOKED FOR REEL; Invitation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ... will be available for inspection and copying at the above address between 10 a.m. and 5 p.m., E.T., Monday through Friday, except federal holidays. An electronic version of this document and all documents... HOOKED FOR REEL is: INTENDED COMMERCIAL USE OF VESSEL: Sport fishing charters GEOGRAPHIC REGION: Michigan...

  7. A Treatise on Equivalent-Plate Stiffnesses for Stiffened Laminated-Composite Plates and Plate-Like Lattices

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    2011-01-01

    A survey of studies conducted since 1914 on the use of equivalent-plate stiffnesses in modeling the overall, stiffness-critical response of stiffened plates and shells is presented. Two detailed, comprehensive derivations of first-approximation equivalent-plate stiffnesses are also presented that are based on the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. Equivalent-plate stiffness expressions, and a corresponding symbolic manipulation computer program, are also presented for several different stiffener configurations. These expressions are very general and exhibit the full range of anisotropies permitted by the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. The expressions presented in the present study were also compared with available, previously published results. For the most part, the previously published results are for special cases of the general expressions presented herein and are almost in complete agreement. Analysis is also presented that extends the use of the equivalent-plate stiffness expressions to sandwich plates.

  8. Cold plate

    DOEpatents

    Marroquin, Christopher M.; O'Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  9. Dereplication-guided isolation of a new indole alkaloid triglycoside from the hooks of Uncaria rhynchophylla by LC with ion trap time-of-flight MS.

    PubMed

    Zhang, Jian-Gang; Huang, Xiao-Yan; Ma, Yun-Bao; Zhang, Xue-Mei; Chen, Ji-Jun; Geng, Chang-An

    2018-04-01

    Uncaria rhynchophylla (Gou-Teng) as the monarch herb of many formulae (Fufang), e.g. "Tian-Ma-Gou-Teng-Yin," "Ling-Jiao-Gou-Teng-Yin," and "Yi-Gan-San", is a famous traditional Chinese medicine documented in the Chinese pharmacopoeia for mental and cardiovascular diseases. In the traditional Chinese medicine system, only the hook-bearing stems are used as the crude materials for Gou-Teng, and the hooks are always considered more effective than the stems. Focusing on the mono-herb and its active constituents from combinatorial formulae is the core idea of reductionism of traditional Chinese medicine theory. Detailed liquid chromatography with mass spectrometry analysis on the hooks of U. rhynchophylla was performed to profile the chemical constituents based on tandem mass spectrometry fragmentation and UV absorption. Under the guidance of liquid chromatography with ion trap/time-of-flight mass spectrometry, one new indole alkaloid triglycoside (1), together with five known compounds 2-6 as the main constituents, were isolated from the hooks of U. rhynchophylla by various column chromatography methods. Compound 1 showed moderate activity on MT 1 and MT 2 melatonin receptors with agonistic rates of 79.6 and 46.3% at the concentration of 1 mM. This dereplication strategy can be equally applicable to rapidly disclose the active constituents of other Chinese herbs through targeted purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Therapeutic effects of total alkaloids of Tripterygium wilfordii Hook f. on collagen-induced arthritis in rats.

    PubMed

    Zhang, Yuqin; Xu, Wei; Li, Huang; Zhang, Xun; Xia, Yufa; Chu, Kedan; Chen, Lidian

    2013-02-13

    Tripterygium wilfordii Hook f. is one of Traditional Chinese Medicines which is commonly used to treat rheumatoid arthritis (RA). The total alkaloids were the main constituent part of Tripterygium wilfordii Hook f. It has a great significance to study the effects of the total alkaloids of Tripterygium wilfordii Hook f. (ATW) on RA. This paper aims at investigating the therapeutic effect of ATW on RA and its possible mechanism, and providing a theoretical and experimental basis for the clinical use of ATW. The model of wistar rats of type II collagen-induced arthritis (CIA) was made, and the rats were perfused a stomach with ATW for 4 weeks continuously. Then the levels of interleukin (IL)-6, IL-8, tumor necrosis factor (TNF)-, in the serum of CIA rats were detected by enzyme linked immunosorbent assay (ELISA), and the joint pathological section of CIA rats was observed by hematoxylin and eosin (HE) staining method and the expression of IL-6, IL-8, nuclear factor kappa B (NF-κB), TNF-α were measure by immunohistochemistry staining method. Compared with model group, ATW could significantly reduce paw swelling and suppresse articular cartilage degenerated. The results also found that there was significant reduction levels of IL-6, IL-8 and TNF-α in serum of CIA rats treated with ATW and ATW inhibited the expression of IL-6, IL-8, NF-κB, TNF-α in synovial tissue. ATW not only could inhibit the symptom of CIA rats significantly but also could inhibit the production of IL-6, IL-8, TNF-α in serum and the expression of IL-6, IL-8, NF-κB and TNF-α in synovial tissue targeting the inflammatory. ATW would be a drug as a novel botanical drug for the treatment of RA. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Simplified radius, ulna, and short bone-age assessment procedure using grouped-Tanner-Whitehouse method.

    PubMed

    Hsieh, Chi-Wen; Liu, Tzu-Chiang; Wang, Jui-Kai; Jong, Tai-Lang; Tiu, Chui-Mei

    2011-08-01

    The Tanner-Whitehouse III (TW3) method is popular for assessing children's bone age, but it is time-consuming in clinical settings; to simplify this, a grouped-TW algorithm (GTA) was developed. A total of 534 left-hand roentgenograms of subjects aged 2-15 years, including 270 training and 264 testing datasets, were evaluated by a senior pediatrician. Next, GTA was used to choose the appropriate candidate of radius, ulna, and short bones and to classify the bones into three groups by data mining. Group 1 was composed of the maturity pattern of the radius and the middle phalange of the third and fifth digits and three weights were obtained by data mining, yielding a result similar to that of TW3. Subsequently, new bone-age assessment tables were constructed for boys and girls by linear regression and fuzzy logic. In addition, the Bland-Altman plot was utilized to compare accuracy between the GTA, the Greulich-Pyle (GP), and the TW3 method. The relative accuracy between the GTA and the TW3 was 96.2% in boys and 95% in girls, with an error of 1 year, while that between the assessment results of the GP and TW3 was about 87%, with an error of 1 year. However, even if the three weights were not optimally processed, GTA yielded a marginal result with an accuracy of 78.2% in boys and 79.6% in girls. GTA can efficiently simplify the complexity of the TW3 method, while maintaining almost the same accuracy. The relative accuracy between the assessment results of GTA and GP can also be marginal. © 2011 The Authors. Pediatrics International © 2011 Japan Pediatric Society.

  12. Zernike phase contrast cryo-electron tomography of sodium-driven flagellar hook-basal bodies from Vibrio alginolyticus.

    PubMed

    Hosogi, Naoki; Shigematsu, Hideki; Terashima, Hiroyuki; Homma, Michio; Nagayama, Kuniaki

    2011-01-01

    Vibrio alginolyticus use flagella to swim. A flagellum consists of a filament, hook and basal body. The basal body is made up of a rod and several ring structures. This study investigates the structure of the T ring which is a unique component of the V. alginolyticus sodium ion-driven flagellar basal body. Using Zernike phase contrast (ZPC) cryo-electron tomography, we compared the 3D structures of purified hook-basal bodies (HBB) from a wild-type strain (KK148) and a deletion mutant lacking MotX and MotY (TH3), which are thought to form the T ring. ZPC images of HBBs had highly improved signal-to-noise ratio compared to conventional phase contrast images. We observed the outline of the HBBs from strains KK148 and TH3, and the TH3 mutant was missing its T ring. In the wild-type strain, the T ring was beneath the LP ring and seemed to form a ring shape with diameter of 32 nm. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. Composite and Component Plates, Plate Non-rigidity, and the Steadiness of Plate Motion From Marine Geophysical and Space Geodetic Data

    NASA Astrophysics Data System (ADS)

    Gordon, R. G.; Argus, D. F.; DeMets, C.

    2017-12-01

    Plate tectonic theory has evolved since its birth 50 years ago. In particular, we now recognize that some of the originally proposed plates such as the Indo-Australia plate, the Africa plate, and the America plate are what we term "composite" plates—entities that contain no traditionally defined narrow plate boundaries, but are composed of multiple approximately rigid regions, which we term "component" plates, separated by diffuse plate boundaries. The best example of a composite plate is the Indo-Australia composite plate, which consists of the India, Capricorn, Australia, and Macquarie component plates and multiple intervening diffuse oceanic plate boundaries. The poles of relative rotation between component plates tend to lie in their mutual diffuse plate boundary. Outside of diffuse boundaries, plate rigidity has proven to be an excellent approximation, but the non-closure of some plate circuits indicates that stable plate interiors have a small but significant non-rigidity that may add up to 1 to 2 mm/a across any individual plate and may be partly due to horizontal thermal contraction of oceanic lithosphere. The greatest observational challenge to plate rigidity is posed by the Pacific-Cocos-Nazca plate circuit, which fails closure by 15 ±4 mm/a. The most rapid deformation of the plates observed with space geodesy is generated by solid Earth's viscous response to unloading of the late Pleistocene ice sheets. Differences between different realizations of global plate velocities from space geodesy appear in some cases to be due to differing assumptions about the motion of the geocenter, which affects estimated plate relative angular velocities and estimated vertical motion at geodetic sites. Comparison of space geodetic and marine geophysical plate motion rates and directions has demonstrated that plate motion is nearly steady, which allows plate boundary conditions to be applied to inter-seismic strain accumulation due to locking of specific faults. In

  14. Risk Factors and Consequences of Unwanted Sex among University Students: Hooked up, Alcohol, and Stress Response

    ERIC Educational Resources Information Center

    Flack, William F., Jr.; Daubman, Kimberly A.; Caron, Marcia L.; Asadorian, Jenica A.; D'Aureli, Nicole R.; Gigliotti, Shannon N.; Hall, Anna T.; Kiser, Sarah; Stine, Erin R.

    2007-01-01

    This is the first study of unwanted sexual experiences in the collegiate "hooking-up" culture. In a representative sample of 178 students at a small liberal arts university. Twenty-three percent of women and 7% of men surveyed reported one or more experiences of unwanted sexual intercourse. Seventy-eight percent of unwanted vaginal, anal, and oral…

  15. Flavonoids from the stems of Croton caudatus Geisel. var. tomentosus Hook.

    PubMed

    Zou, Guo-An; Su, Zhi-Heng; Zhang, Hong-Wu; Wang, Yuan; Yang, Jun-Shan; Zou, Zhong-Mei

    2010-02-26

    A new flavone, named crotoncaudatin (1), was isolated from the stems of Croton caudatus Geisel. var. tomentosus Hook., together with nine known analogues: 3,5,6,7,8,3',4'-heptamethoxyflavone (2), tangeretin (3), nobiletin (4), 5,6,7,4'-tetramethoxy-flavone (5), sinensetin (6), kaempferol (7), tiliroside (8), kaempferol-3-O-rutinoside (9) and rutin (10). The structures of the above compounds were established by a combination of spectroscopic methods, including HR-ESI-MS, 1H-NMR, 13C-NMR, HMQC and HMBC spectra. All compounds were isolated from and identified in this species for the first time and compounds 1-6 are new for the genus Croton.

  16. Comparison of three methods of calculating strain in the mouse ulna in exogenous loading studies.

    PubMed

    Norman, Stephanie C; Wagner, David W; Beaupre, Gary S; Castillo, Alesha B

    2015-01-02

    Axial compression of mouse limbs is commonly used to induce bone formation in a controlled, non-invasive manner. Determination of peak strains caused by loading is central to interpreting results. Load-strain calibration is typically performed using uniaxial strain gauges attached to the diaphyseal, periosteal surface of a small number of sacrificed animals. Strain is measured as the limb is loaded to a range of physiological loads known to be anabolic to bone. The load-strain relationship determined by this subgroup is then extrapolated to a larger group of experimental mice. This method of strain calculation requires the challenging process of strain gauging very small bones which is subject to variability in placement of the strain gauge. We previously developed a method to estimate animal-specific periosteal strain during axial ulnar loading using an image-based computational approach that does not require strain gauges. The purpose of this study was to compare the relationship between load-induced bone formation rates and periosteal strain at ulnar midshaft using three different methods to estimate strain: (A) Nominal strain values based solely on load-strain calibration; (B) Strains calculated from load-strain calibration, but scaled for differences in mid-shaft cross-sectional geometry among animals; and (C) An alternative image-based computational method for calculating strains based on beam theory and animal-specific bone geometry. Our results show that the alternative method (C) provides comparable correlation between strain and bone formation rates in the mouse ulna relative to the strain gauge-dependent methods (A and B), while avoiding the need to use strain gauges. Published by Elsevier Ltd.

  17. [Topographic anatomy of the hook region and its significance for the choice of the surgical technique for the cochlear implantation].

    PubMed

    Yanov, Yu K; Kuzovkov, V E; Lilenko, A S; Kostevich, I V; Sugarova, S B; Amonov, A Sh

    The mode of the introduction of the active electrode of a cochlear implant into the cochlea remains a key issue as far as cochlear implantation is concerned. Especially much attention has recently been given to the relationship between the anatomical features of the basal region of the cochlea (the so-called 'fish hook') and the possibility to approach it. We have undertaken the attempt to optimize the approach to the tympanic canal (scala tympanica) of the cochlea with a view to reducing to a minimum the risk of an injury to the cochlear structures in the course of cochlear implantation. A total of 35 cadaveric temporal bones were examined to measure the fine structures of the hook region and evaluate the risk of their damages associated with various approaches to the tympanic canal.

  18. Comminuted olecranon fracture fixation with pre-contoured plate: Comparison of composite and cadaver bones

    PubMed Central

    Hamilton Jr, David A; Reilly, Danielle; Wipf, Felix; Kamineni, Srinath

    2015-01-01

    AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model. METHODS: Five samples of fourth generation composite bones and five samples of fresh frozen human cadaveric left ulnae were utilized for this study. The cadaveric specimens underwent dual-energy X-ray absorptiometry (DEXA) scanning to quantify the bone quality. The composite and cadaveric bones were prepared by creating a comminuted olecranon fracture and fixed with a pre-contoured olecranon plate with locking screws. Construct stiffness and failure load were measured by subjecting specimens to cantilever bending moments until failure. Fracture site motion was measured with differential variable resistance transducer spanning the fracture. Statistical analysis was performed with two-tailed Mann-Whitney-U test with Monte Carlo Exact test. RESULTS: There was a significant difference in fixation stiffness and strength between the composite bones and human cadaver bones. Failure modes differed in cadaveric and composite specimens. The load to failure for the composite bones (n = 5) and human cadaver bones (n = 5) specimens were 10.67 nm (range 9.40-11.91 nm) and 13.05 nm (range 12.59-15.38 nm) respectively. This difference was statistically significant (P ˂ 0.007, 97% power). Median stiffness for composite bones and human cadaver bones specimens were 5.69 nm/mm (range 4.69-6.80 nm/mm) and 7.55 nm/mm (range 6.31-7.72 nm/mm). There was a significant difference for stiffness (P ˂ 0.033, 79% power) between composite bones and cadaveric bones. No correlation was found between the DEXA results and stiffness. All cadaveric specimens withstood the physiologic load anticipated postoperatively. Catastrophic failure occurred in all composite specimens. All failures resulted from composite bone failure at the distal screw site and not hardware failure. There were no catastrophic fracture failures in the cadaveric

  19. Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.

    PubMed

    Cormano, Julia; Mackay, Gillian; Holschneider, Christine

    2015-10-01

    A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.

  20. Resolution of an apparent hook effect in Roche partner DRI oxycodone immunoassay.

    PubMed

    Colón-Franco, Jessica M; Cox, Elbert T; Crosby, David B; Dawling, Sheila

    2013-01-01

    A presumed hook effect in the semiquantitative DRI Oxycodone immunoassay, OXY3S (Cobas Integra, Roche Diagnostics), was investigated in 14 urine samples with gas chromatography/mass spectrometry (GC-MS) >10,000 ng/mL but OXY3S <1,000 ng/mL. These samples included the index case, a false-negative OXY3S result with >75,000 ng/mL oxycodone + oxymorphone by GC-MS confirmation. Patient samples needed 2- to 16-fold dilution to obtain the correct OXY3S response. The OXY3S test did not hook at high-spiked concentrations of oxycodone, oxymorphone or oxymorphone-3β-d-glucuronide in drug-free urine. The OXY3S test parameters were replicated in a development channel on the Cobas using DRI Reagents (Microgenics, CA, USA) and were subsequently modified. Delayed sample addition or doubling of Reagent 1 (R1: antibody/substrate/co-factor) yielded maximal immunoassay response (>10,000 ng/mL) in 12 of 14 and 14 of 14 undiluted patient samples, respectively. Supplementation of R1 with substrate alone did not correctly recover oxycodone from any of the samples, while co-factor supplementation resulted a maximal OXY3S response in 13 of 14 samples. The remaining (index) sample could only be corrected by supplemental R1. The semiquantitative utility of the DRI Oxycodone assay is questionable. Although the precise cause of the under-recovery could not be determined, the modification presented permits reliable oxycodone determination at the high concentrations frequently seen in clinical urine samples.

  1. Effect of Pin Length on Hook Size and Joint Properties in Friction Stir Lap Welding of 7B04 Aluminum Alloy

    NASA Astrophysics Data System (ADS)

    Wang, Min; Zhang, Huijie; Zhang, Jingbao; Zhang, Xiao; Yang, Lei

    2014-05-01

    Friction stir lap welding of 7B04 aluminum alloy was conducted in the present paper, and the effect of pin length on hook size and joint properties was investigated in detail. It is found that for each given set of process parameters, the size of hook defect on the advancing side shows an "M" type evolution trend as the pin length is increased. The affecting characteristics of pin length on joint properties are dependent on the heat input levels. When the heat input is low, the fracture strength is firstly increased to a peak value and then shows a decrease. When the heat input is relatively high, the evolution trend of fracture strength tends to exhibit a "W" type with increasing the pin length.

  2. Two M-T hook residues greatly improve the antiviral activity and resistance profile of the HIV-1 fusion inhibitor SC29EK

    PubMed Central

    2014-01-01

    Background Peptides derived from the C-terminal heptad repeat (CHR) of HIV-1 gp41 such as T20 (Enfuvirtide) and C34 are potent viral fusion inhibitors. We have recently found that two N-terminal residues (Met115 and Thr116) of CHR peptides form a unique M-T hook structure that can greatly enhance the binding and anti-HIV activity of inhibitors. Here, we applied two M-T hook residues to optimize SC29EK, an electrostatically constrained peptide inhibitor with a potent anti-HIV activity. Results The resulting peptide MT-SC29EK showed a dramatically increased binding affinity and could block the six-helical bundle (6-HB) formation more efficiently. As expected, MT-SC29EK potently inhibited HIV-1 entry and infection, especially against those T20- and SC29EK-resistant HIV-1 variants. More importantly, MT-SC29EK and its short form (MT-SC22EK) suffered from the difficulty to induce HIV-1 resistance during the in vitro selection, suggesting their high genetic barriers to the development of resistance. Conclusions Our studies have verified the M-T hook structure as a vital strategy to design novel HIV-1 fusion inhibitors and offered an ideal candidate for clinical development. PMID:24884671

  3. Performance optimization of plate heat exchangers with chevron plates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muley, A.; Manglik, R.M.

    1999-07-01

    The enhanced heat transfer performance of a chevron plate heat exchanger (PHE) is evaluated employing (1) energy-conservation based performance evaluation criteria (PECs), and (2) the second-law based minimization of entropy generation principle. Single-phase laminar and turbulent flow convection for three different chevron-plate arrangements are considered. The influence of plate surface corrugation characteristics and their stack arrangements on the heat exchanger's thermal-hydraulic performance is delineated. Based on the different figures of merit, the results show that the extent of heat transfer enhancement increases with flow Re and chevron angle {beta} in laminar flow, but it diminishes with increasing Re in turbulentmore » flows. With up to 2.9 times higher Q, 48% lower A, and entropy generation number N{sub s,a} {lt} 1, relative to an equivalent flat-plate pack, chevron plates are found to be especially suitable in the low to medium flow rates range (20 {le} Re {le} 2,000). Also, there appears to be no significant advantage of using a mixed-plate over a symmetric-plate arrangement.« less

  4. Evaluation of finger plate and flat plate connection design.

    DOT National Transportation Integrated Search

    2016-01-01

    This project investigates the cause(s) of premature deterioration of MoDOT finger plate and flat plate expansion devices : under high traffic volumes and then uses that information to design new Load and Resistance Factor Design (LRFD) : finger plate...

  5. Concentric ring flywheel with hooked ring carbon fiber separator/torque coupler

    DOEpatents

    Kuklo, Thomas C.

    1999-01-01

    A concentric ring flywheel with expandable separators, which function as torque couplers, between the rings to take up the gap formed between adjacent rings due to differential expansion between different radius rings during rotation of the flywheel. The expandable separators or torque couplers include a hook-like section at an upper end which is positioned over an inner ring and a shelf-like or flange section at a lower end onto which the next adjacent outer ring is positioned. As the concentric rings are rotated the gap formed by the differential expansion there between is partially taken up by the expandable separators or torque couplers to maintain torque and centering attachment of the concentric rings.

  6. Concentric ring flywheel with hooked ring carbon fiber separator/torque coupler

    DOEpatents

    Kuklo, T.C.

    1999-07-20

    A concentric ring flywheel with expandable separators, which function as torque couplers, between the rings to take up the gap formed between adjacent rings due to differential expansion between different radius rings during rotation of the flywheel. The expandable separators or torque couplers include a hook-like section at an upper end which is positioned over an inner ring and a shelf-like or flange section at a lower end onto which the next adjacent outer ring is positioned. As the concentric rings are rotated the gap formed by the differential expansion there between is partially taken up by the expandable separators or torque couplers to maintain torque and centering attachment of the concentric rings. 2 figs.

  7. Details: Elevation of Plate Typical Bay, SectionThrough Plate Typical Bay, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Details: Elevation of Plate Typical Bay, Section-Through Plate Typical Bay, Section-Through Plate Center Bay, Elevation of Plate Center Bay - Contoocook Covered Bridge, Spanning Contoocook River, Hopkinton, Merrimack County, NH

  8. The anisotropic Hooke's law for cancellous bone and wood.

    PubMed

    Yang, G; Kabel, J; van Rietbergen, B; Odgaard, A; Huiskes, R; Cowin, S C

    A method of data analysis for a set of elastic constant measurements is applied to data bases for wood and cancellous bone. For these materials the identification of the type of elastic symmetry is complicated by the variable composition of the material. The data analysis method permits the identification of the type of elastic symmetry to be accomplished independent of the examination of the variable composition. This method of analysis may be applied to any set of elastic constant measurements, but is illustrated here by application to hardwoods and softwoods, and to an extraordinary data base of cancellous bone elastic constants. The solid volume fraction or bulk density is the compositional variable for the elastic constants of these natural materials. The final results are the solid volume fraction dependent orthotropic Hooke's law for cancellous bone and a bulk density dependent one for hardwoods and softwoods.

  9. Outcome of distal end clavicle fractures treated with locking plates.

    PubMed

    Vaishya, Raju; Vijay, Vipul; Khanna, Vikram

    2017-02-01

    of motion of the shoulder with the hook plates and failure of fixation in screw and K-wire fixations. It may well be the answer to the fixation questions of the lateral clavicle fractures, although larger comparative studies between the surgical treatment methods are required to confirm the same. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  10. Cytotoxic bibenzyl dimers from the stems of Dendrobium fimbriatum Hook.

    PubMed

    Xu, Feng-Qing; Xu, Fang-Cheng; Hou, Bo; Fan, Wei-Wei; Zi, Cheng-Ting; Li, Yan; Dong, Fa-Wu; Liu, Yu-Qing; Sheng, Jun; Zuo, Zhi-Li; Hu, Jiang-Miao

    2014-11-15

    The bioassay-guided chemical investigation of the stems of Dendrobium fimbriatum Hook led to the isolation of seven first reported bibenzyl dimers with a linkage of a methylene moiety, fimbriadimerbibenzyls A-G (1-7), together with a new dihydrophenanthrene derivative (S)-2,4,5,9-tetrahydroxy-9,10-dihydrophenanthrene (8) and thirteen known compounds (9-21). The structure of the new compound was established by spectroscopic analysis. Biological evaluation of bibenzyl derivatives against five human cell lines indicated that seven of those compounds exhibited broad-spectrum and cytotoxic activities with IC50 values ranging from 2.2 to 21.2 μM. Those rare bibenzyl dimers exhibited cytotoxic activities in vitro and the cytotoxicity decreased as the number of oxygen-containing groups in the structure decreases. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Indexing of randomised controlled trials of physiotherapy interventions: a comparison of AMED, CENTRAL, CINAHL, EMBASE, hooked on evidence, PEDro, PsycINFO and PubMed.

    PubMed

    Moseley, Anne M; Sherrington, Catherine; Elkins, Mark R; Herbert, Robert D; Maher, Christopher G

    2009-09-01

    To compare the comprehensiveness of indexing the reports of randomised controlled trials of physiotherapy interventions by eight bibliographic databases (AMED, CENTRAL, CINAHL, EMBASE, Hooked on Evidence, PEDro, PsycINFO and PubMed). Audit of bibliographic databases. Two hundred and eighty-one reports of randomised controlled trials of physiotherapy interventions were identified by screening the reference lists of 30 relevant systematic reviews published in four consecutive issues of the Cochrane Database of Systematic Reviews (Issue 3, 2007 to Issue 2, 2008). AMED, CENTRAL, CINAHL, EMBASE, Hooked on Evidence, PEDro, PsycINFO and PubMed were used to search for the trial reports. The number of trial reports indexed in each database was calculated. PEDro indexed 99% of the trial reports, CENTRAL indexed 98%, PubMed indexed 91%, EMBASE indexed 82%, CINAHL indexed 61%, Hooked on Evidence indexed 40%, AMED indexed 36% and PsycINFO indexed 17%. Most trial reports (92%) were indexed on four or more of the databases. One trial report was indexed on a single database (PEDro). Of the eight bibliographic databases examined, PEDro and CENTRAL provide the most comprehensive indexing of reports of randomised trials of physiotherapy interventions.

  12. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  13. Plate mode velocities in graphite/epoxy plates

    NASA Technical Reports Server (NTRS)

    Prosser, W. H.; Gorman, M. R.

    1994-01-01

    Measurements of the velocities of the extensional and flexural plate modes were made along three directions of propagation in four graphite/epoxy composite plates. The acoustic signals were generated by simulated acoustic emission events (pencil lead breaks or Hsu-Neilson sources) and detected by by broadband ultrasonic transducers. The first arrival of the extensional plate mode, which is nondispersive at low frequencies, was measured at a number of different distances from the source along the propagation direction of interest. The velocity was determined by plotting the distance versus arrival time and computing its slope. Because of the large dispersion of the flexural mode, a Fourier phase velocity technique was used to characterize this mode. The velocity was measured up to a frequency of 160 kHz. Theoretical predictions of the velocities of these modes were also made and compared with experimental observations. Classical plate theory yields good agreement with the measured extensional velocities. For predictions of the dispersion of the flexural mode, Mindlin plates theory, which includes the effects of shear deformation and rotatory inertia was shown to give better agreement with the experimental measurements.

  14. Plato crater, first observative session: not any "hook" but a shark fin? (Italian Title: La 1° Campagna Osservativa del cratere Plato: non un "uncino" ma una "pinna di squalo"?)

    NASA Astrophysics Data System (ADS)

    Mercatali, A.

    2018-01-01

    On 1st March 2012 an observative session of Moon's Plato crater was made. The purpose of these observations was to check the presence of one shadow with "hook" form at the inner of Plato crater already reported by H. Percy Wilkins, 3th April 21:30 UT, 1952. The results obtained by us have not shown any shadow with an hook form, but a shadow like a shark fin.

  15. Paper microzone plates.

    PubMed

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  16. Design and assessment of a wrapped cylindrical Ca-P AZ31 Mg alloy for critical-size ulna defect repair.

    PubMed

    Smith, Montserrat Rabago; Atkinson, Patrick; White, Désirée; Piersma, Tyler; Gutierrez, Gloria; Rossini, Gianny; Desai, Sapna; Wellinghoff, Stephen; Yu, Hui; Cheng, Xingguo

    2012-01-01

    Recently, magnesium has been investigated as a promising bioresorbable orthopedic biomaterial. Its mechanical properties are very similar to natural bone, making it appropriate for load-bearing orthopedic fracture repair applications. However, significant hurdles remain regarding the design of practical implants and methods to control degradation and enhance biocompatibility. Although attempts have been made to hinder magnesium's rapid corrosion via alloying and coating, these studies have used solid monoliths. In an effort to reduce the amount of alloy used for implantation in a shape that mimics cortical bone shape, this study used a thin sheet of Mg AZ31 which was rolled into hollow cylindrical scaffolds. The scaffold was coated with different amounts of Ca-P; this implant demonstrated slowed corrosion in simulated body fluid (SBF) as well as enhanced biocompatibility for mesenchymal stem cells (MSC). In vivo implantation of magnesium alloy scaffold adjacent to the rat femur showed significant biointegration with further deposition of complex Mg-Ca phosphates/carbonates typical of natural bone. Finally, the implant was placed in a critical-size ulna defect in live rabbits, which lead to radiographic union and partial restoration of biomechanical strength in the defect. This study demonstrated that a thin sheet of coated Mg alloy that was spirally wrapped wound be a promising orthopedic biomaterial for bone repair. Copyright © 2011 Wiley Periodicals, Inc.

  17. False Negative Urine Pregnancy Testing with Complete Molar Pregnancy: An Example of the Hook Effect.

    PubMed

    Anderson, Zachary; Larson, Eric; Khan, Muhammad; Bell, Maria

    2016-02-01

    Gestational trophoblastic disease (GTD) encompasses a group of tumors derived from trophoblasts, which normally form the placenta during pregnancy. Human chorionic gonadotropin (hCG) is a glycoprotein composed of an alpha subunit identical to that of thyroid stimulating hormone (TSH), follicle-stimulating hormone (FSH), and luteinizing hormone (LH). Detection of beta-hCG is achievable in both urine and serum samples, proving useful for the detection of normal pregnancy and GTD. However, in the presence of very high levels of beta-hCG, a false negative result may be obtained due to a phenomenon called the "hook effect" or "prozone phenomenon." In certain circumstances, trophoblastic tumors can produce very high levels of beta-hCG, causing misleading results on urine pregnancy testing. A 49-year-old Caucasian female with past medical history pertinent for deep vein thrombosis, ovarian cysts, and osteopenia presented to her internist with report of irregular uterine bleeding for the preceding three months, accompanied by complaints of abdominal bloating, night sweats, and constipation. The patient stated she had completed two negative qualitative urine pregnancy tests and had been seen by both gynecology and gastroenterology, with recommendations to start supplemental estrogen for her symptoms and begin additional fiber intake for irritable bowel syndrome, respectively. Despite negative urine beta-hCG, a quantitative serum beta-hCG was obtained and revealed a level greater than 200,000 international units (IU). The patient was referred to gynecologic oncology and an open abdominal hysterectomy with preservation of her ovaries was performed. Histopathologic examination showed a complete hydatiform mole with no evidence of invasion. The case highlights the importance of clinical judgment in modern medicine, where biochemical methods and imaging modalities have become main stays in diagnosis. As mentioned, there are ways to reduce the incidence of the hook effect, but

  18. Effect of the Mandibular Orthopedic Repositioning Appliance (MORA) on Forearm Muscle Activation and Grasping Power during Pinch and Hook Grip.

    PubMed

    Lee, Sang-Yeol; Park, Yi-Jeong; Park, Hye-Min; Bae, Hae-Jin; Yu, Min-Ji; Choi, Hee-Won; Hwang, Na-Young

    2014-02-01

    [Purpose] This study verified the changes in muscle activities and grasping power during maximal isometric exercise of the forearm and masseter muscle with and without a mandibular orthopedic repositioning appliance (MORA). It also offers basic data for defining the correlation of function of hand with mouth. [Methods] EMG was used to measure masticatory muscle, flexor bundle and extensor bundle activities with or without MORA while subjects performed the hook grip and pinch grip. The measuring tool used for measuring grip strength was the same as that used for measuring pinch and hook strength. The subjects were 28 healthy young adults. [Result] Muscle activity and grasping power significantly increased when wearing the MORA. [Conclusion] The result indicates that wearing MORA can increase muscle activity and grasping power of forearm and masseter muscle. We think wearing MORA might help improve the function of the forearm because it activates the function of the masseter.

  19. Angular shear plate

    DOEpatents

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  20. Comparison of strains produced by titanium and poly D, L-lactide Acid plating systems to in vitro forces.

    PubMed

    Chacon, Guillermo E; Dillard, Frederick Matt; Clelland, Nancy; Rashid, Robert

    2005-07-01

    To determine if a specific resorbable plating system provides similar fixation, in terms of strain distribution under load, to a titanium system when the Champy technique is applied for the treatment of a mandibular angle fracture. A formalin-fixed cadaver mandible was harvested just before the study. A bicortical osteotomy was then made using a diamond disc extending in an oblique direction in the area of the angle. It was then passively fixated with a 4-hole 2.0-mm miniplate. Two stacked rosette strain gauges were bonded to the mandible on either side of the fracture. Each rosette had 3 strain gauges arranged in specific degrees relative to each other. The mandible was then placed on a dynanometer and 30 lb loads were delivered on the ipsilateral molar. Static resistance was placed in the condylar neck region to simulate the glenoid fossa. Loading was repeated 10 times with a period of 3 minutes between loads. Measurements were recorded for each strain gauge after loads were in place for 30 seconds. The same process was repeated using a 4-hole 2.1-mm resorbable miniplate. The strains were then used to calculate the maximum and minimum strains for each rosette. Hooke's law was used to calculate the principal stresses. Differences were observed between the strain gauges for each individual plating system. There was variability within the resorbable plate measurements as shown by the standard deviation. Using the REML ANOVA test, a significant difference was found between the 2 materials. In this in vitro study, there were significant biomechanical differences observed between a 2.0-mm titanium miniplate and a 2.1-mm resorbable miniplate when used to treat a mandibular angle fracture following Champy's principles. Based on our finding, both systems cannot be used interchangeably for the treatment of mandibular angle fractures under the same clinical conditions.

  1. The Flagellar Hook Protein, FlgE, of Salmonella enterica Serovar Typhimurium Is Posttranscriptionally Regulated in Response to the Stage of Flagellar Assembly

    PubMed Central

    Bonifield, Heather R.; Yamaguchi, Shigeru; Hughes, Kelly T.

    2000-01-01

    We investigated the posttranscriptional regulation of flgE, a class 2 gene that encodes the hook subunit protein of the flagella. RNase protection assays demonstrated that the flgE gene was transcribed at comparable levels in numerous strains defective in known steps of flagellar assembly. However, Western analyses of these strains demonstrated substantial differences in FlgE protein levels. Although wild-type FlgE levels were observed in strains with deletions of genes encoding components of the switch complex and the flagellum-specific secretion apparatus, no protein was detected in a strain with deletions of the rod, ring, and hook-associated proteins. To determine whether FlgE levels were affected by the stage of hook–basal-body assembly, Western analysis was performed on strains with mutations at individual loci encompassed by the deletion. FlgE protein was undetectable in rod mutants, intermediate in ring mutants, and wild type in hook-associated protein mutants. The lack of negative regulation in switch complex and flagellum-specific secretion apparatus deletion mutants blocked for flagellar construction prior to rod assembly suggests that these structures play a role in the negative regulation of FlgE. Quantitative Western analyses of numerous flagellar mutants indicate that FlgE levels reflect the stage at which flagellar assembly is blocked. These data provide evidence for negative posttranscriptional regulation of FlgE in response to the stage of flagellar assembly. PMID:10869084

  2. Using a simulation model to assess risk of false negative point-of-care urinary human chorionic gonadotropin device results due to high-dose hook interference.

    PubMed

    Milhorn, Denise; Korpi-Steiner, Nichole

    2015-02-01

    It is unclear if the point-of-care (POC) Clinitest hCG device is subject to high-dose hook interference from physiological concentrations of intact human chorionic gonadotropin (hCG), β-core fragment of hCG (hCGβcf), and hCG free β-subunit (hCGβ) found in urine during pregnancy. We used a simulation model to address this question and related our findings to our institution's pregnant population in order to assess risk for potential false-negative hCG results. The expected distribution of days relative to ovulation during routine POC hCG testing was estimated from 182 patients. Clinitest-Clinitek Status hCG device susceptibility to high-dose hook interference from hCG variants and potential risk of false-negative results as it relates to this population were evaluated by testing increasing concentrations of hCG, hCGβcf, hCGβ as well as urine simulating physiological hCG, hCGβcf and hCGβ concentrations expected during early pregnancy (≤44 days post-ovulation). The Clinitest-Clinitek Status hCG device exhibited high-dose hook interference from hCGβcf alone, but not from hCG, hCGβ, or simulated physiological urinary concentrations of combined hCG, hCGβcf and hCGβ expected during early pregnancy. The majority of our patient population had urinary hCG testing conducted during early pregnancy. The Clinitest-Clinitek Status hCG device is unlikely to exhibit false-negative urinary hCG results due to high-dose hook interference for women in early healthy pregnancy, although additional studies are necessary to determine potential risk in other patient populations. Visual interpretation of POC urinary hCG device results is an important failure mode to consider in risk analyses for erroneous urinary hCG device results. Published by Elsevier Inc.

  3. The mathematical formulation of a generalized Hooke's law for blood vessels.

    PubMed

    Zhang, Wei; Wang, Chong; Kassab, Ghassan S

    2007-08-01

    It is well known that the stress-strain relationship of blood vessels is highly nonlinear. To linearize the relationship, the Hencky strain tensor is generalized to a logarithmic-exponential (log-exp) strain tensor to absorb the nonlinearity. A quadratic nominal strain potential is proposed to derive the second Piola-Kirchhoff stresses by differentiating the potential with respect to the log-exp strains. The resulting constitutive equation is a generalized Hooke's law. Ten material constants are needed for the three-dimensional orthotropic model. The nondimensional constant used in the log-exp strain definition is interpreted as a nonlinearity parameter. The other nine constants are the elastic moduli with respect to the log-exp strains. In this paper, the proposed linear stress-strain relation is shown to represent the pseudoelastic Fung model very well.

  4. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  5. Anterior inferior plating versus superior plating for clavicle fracture: a meta-analysis.

    PubMed

    Ai, Jie; Kan, Shun-Li; Li, Hai-Liang; Xu, Hong; Liu, Yang; Ning, Guang-Zhi; Feng, Shi-Qing

    2017-04-18

    The position of plate fixation for clavicle fracture remains controversial. Our objective was to perform a comprehensive review of the literature and quantify the surgical parameters and clinical indexes between the anterior inferior plating and superior plating for clavicle fracture. PubMed, EMBASE, and the Cochrane Library were searched for randomized and non-randomized studies that compared the anterior inferior plating with the superior plating for clavicle fracture. The relative risk or standardized mean difference with 95% confidence interval was calculated using either a fixed- or random-effects model. Four randomized controlled trials and eight observational studies were identified to compare the surgical parameters and clinical indexes. For the surgical parameters, the anterior inferior plating group was better than the superior plating group in operation time and blood loss (P < 0.05). Furthermore, in terms of clinical indexes, the anterior inferior plating was superior to the superior plating in reducing the union time, and the two kinds of plate fixation methods were comparable in constant score, and the rate of infection, nonunion, and complications (P > 0.05). Based on the current evidence, the anterior inferior plating may reduce the blood loss, the operation and union time, but no differences were observed in constant score, and the rate of infection, nonunion, and complications between the two groups. Given that some of the studies have low quality, more randomized controlled trails with high quality should be conduct to further verify the findings.

  6. 77 FR 46125 - Sunoco, Inc., R&M, Refining Division, Marcus Hook, PA; Sunoco, Inc., 10 Industrial Hwy., MS4...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,145; TA-W-81,145A] Sunoco, Inc., R&M, Refining Division, Marcus Hook, PA; Sunoco, Inc., 10 Industrial Hwy., MS4 Building G, Lester, PA; Notice of Negative Determination on Reconsideration On April 30, 2012, the Department of Labor issued an Affirmative Determination Regarding...

  7. 77 FR 29362 - Sunoco, Inc., R&M Refining Division, Marcus Hook, PA; Sunoco, Inc., 10 Industrial Hwy, MS4...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,145; TA-W-81,145A] Sunoco, Inc., R&M Refining Division, Marcus Hook, PA; Sunoco, Inc., 10 Industrial Hwy, MS4 Building G, Lester, PA; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated March 26, 2012, the United Steel Workers Union...

  8. What can Numerical Computation do for the History of Science? (Study of an Orbit Drawn by Newton on a Letter to Hooke)

    NASA Astrophysics Data System (ADS)

    Stuchi, Teresa; Cardozo Dias, P.

    2013-05-01

    Abstract (2,250 Maximum Characters): On a letter to Robert Hooke, Isaac Newton drew the orbit of a mass moving under a constant attracting central force. How he drew the orbit may indicate how and when he developed dynamic categories. Some historians claim that Newton used a method contrived by Hooke; others that he used some method of curvature. We prove geometrically: Hooke’s method is a second order symplectic area preserving algorithm, and the method of curvature is a first order algorithm without special features; then we integrate the hamiltonian equations. Integration by the method of curvature can also be done exploring geometric properties of curves. We compare three methods: Hooke’s method, the method of curvature and a first order method. A fourth order algorithm sets a standard of comparison. We analyze which of these methods best explains Newton’s drawing.

  9. Geometry of the Cocos Plate Under North American Plate

    NASA Astrophysics Data System (ADS)

    Perez-Campos, X.

    2015-12-01

    The Cocos plate subducts under the North American plate with a complex geometry, and previous seismicity studies revealed some of this complexity. However, details of the geometry and the depth that the plate penetrates werelargely unknown. Since 2004, temporary experiments and the expansion of the permanent network of the Servicio Sismológico Nacional (SSN, Mexican National Seismological Service) have improved resolution of the plate geometry and have helped to map its descent into the upper mantle. Going from northwest to southeast, the Cocos plate appears to be fragmenting into north and south segments. The north segment subducts with an angle of ~30º and the south with an angle of ~10-15º. The transition is smooth near the trench and progresses to a tear at depth; this coincides with the projection of the Orozco Fracture Zone to depth. Also, this transition marks the limit of the presence to the south of an ultra slow velocity layer (USL) on top of the slab.South of this transition, the Cocos plate subducts horizontally , underplating the North American plate for a distance of ~140 to ~300 km from the trench. Along this horizontal region, silent slow events (SSE) and tectonic tremor (TT) have been observed. At a distance of 300 km from the trench (beneath central Mexico), the plate dives into the mantle with an angle of 76º to a depth of 500 km. This geometry changes abruptly to the south, marking the eastern limit of the USL. This change seems to be also characterized by a tear on the slab. Finally to the south, the Cocos plate subducts with a constant angle of 26º. This presentation summarizes the work of many contributors including A. Arciniega-Ceballos, M. Brudzinski, E. Cabral-Cano, T. Chen, R. Clayton,F. Cordoba-Montiel,P. Davis,S. Dougherty,F. Green, M. Gurnis, D. V. Helmberger, A. Husker,A. Iglesias, Y. Kim, V. Manea, D. Melgar, M. Rodríguez-Domínguez,S. K. Singh, T.-R. A. Song, C. M. Valdés-González, D. Valencia-Cabrera

  10. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  11. Effect of Plate Curvature on Blast Response of Structural Steel Plates

    NASA Astrophysics Data System (ADS)

    Veeredhi, Lakshmi Shireen Banu; Ramana Rao, N. V.; Veeredhi, Vasudeva Rao

    2018-04-01

    In the present work an attempt is made, through simulation studies, to determine the effect of plate curvature on the blast response of a door structure made of ASTM A515 grade 50 steel plates. A door structure with dimensions of 5.142 m × 2.56 m × 10 mm having six different radii of curvatures is analyzed which is subjected to blast load. The radii of curvature investigated are infinity (flat plate), 16.63, 10.81, 8.26, 6.61 and 5.56 m. In the present study, a stand-off distance of 11 m is considered for all the cases. Results showed that the door structure with smallest radius of curvature experienced least plastic deformation and yielding when compared to a door with larger radius of curvature with same projected area. From the present Investigation, it is observed that, as the radius of curvature of the plate increases, the deformation mode gradually shifts from indentation mode to flexural mode. The plates with infinity and 16.63 m radius of curvature have undergone flexural mode of deformation and plates with 6.61 and 5.56 m radius of curvature undergo indentation mode of deformation. Whereas, mixed mode of deformation that consists of both flexural and indentation mode of deformations are seen in the plates with radius of curvature 10.81 and 8.26 m. As the radius of curvature of the plate decreases the ability of the plate to mitigate the effect the blast loads increased. It is observed that the plate with smaller radius of curvature deflects most of the blast energy and results in least indentation mode of deformation. The most significant observation made in the present investigation is that the strain energy absorbed by the steel plate gets reduced to 1/3 rd when the radius of curvature is approximately equal to the stand-off distance which could be the critical radius of curvature.

  12. Toxic effects of Tripterygium wilfordii Hook F on the reproductive system of adolescent male rats.

    PubMed

    Jing, Xiaoping; Cheng, Weiwei; Guo, Sheng; Zou, Ya; Zhang, Ting; He, Li

    2017-11-01

    Tripterygium wilfordii Hook F. (TWHF) is a compound extracted from Lei Gong Teng (Thunder God Vine) that has been used to treat a variety of immune-related diseases in clinical practice, particularly in pediatrics. Nevertheless, clinical data indicated that glycosides from Tripterygium wilfordii Hook F (GTW) are toxic to the male reproductive system, but the mechanism is unknown. Here, the administration of a high dose of GTW for 4 weeks and a low dose for 12 weeks can reduce the body weights and testes weights in adolescent male rats. This effect is accompanied by a significantly reduction in the serum testosterone levels. Notably, short-term use of high-dose GTW or long-term use of low-dose GTW leads to testicular damage in adolescent male rats. Furthermore, the expression of the steroidogenic acute regulatory protein (StAR), P450 side chain cleavage enzyme (P450scc), cytochrome P450 17-hydroxylase (P450c17), 3β-hydroxysteroid dehydrogenase (3β-HSD), and 17β-hydroxysteroid dehydrogenase (17β-HSD) mRNAs and proteins in the testes was down-regulated by a short-term treatment with high-dose GTW and a long-term treatment with low-dose GTW. Therefore, GTW exhibit male reproductive toxicity in a concentration-and time-dependent manner by inhibiting the expression of the key enzymes and total cholesterol level involved in testosterone synthesis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. A simulator-based analysis of engineering treatments for right-hook bicycle crashes at signalized intersections.

    PubMed

    Warner, Jennifer; Hurwitz, David S; Monsere, Christopher M; Fleskes, Kayla

    2017-07-01

    A right-hook crash is a crash between a right-turning motor vehicle and an adjacent through-moving bicycle. At signalized intersections, these crashes can occur during any portion of the green interval when conflicting bicycles and vehicles are moving concurrently. The objective of this research was to evaluate the effectiveness of four types of engineering countermeasures - regulatory signage, intersection pavement marking, smaller curb radius, and protected intersection design - at modifying driver behaviors that are known contributing factors in these crashes. This research focused on right-hook crashes that occur during the latter stage of the circular green indication at signalized intersections with a shared right-turn and through lane. Changes in driver performance in response to treatments were measured in a high-fidelity driving simulator. Twenty-eight participants each completed 22 right-turn maneuvers. A partially counterbalanced experimental design exposed drivers to critical scenarios, which had been determined in a previous experiment. For each turn, driver performance measures, including visual attention, crash avoidance, and potential crash severity, were collected. A total of 75 incidents (47 near-collisions and 28 collisions) were observed during the 616 right turns. All treatments had some positive effect on measured driver performance with respect to the right-turn vehicle conflicts. Further work is required to map the magnitude of these changes in driver performance to crash-based outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Hook effect in Abbott i-STAT β-human chorionic gonadotropin (β-hCG) point of care assay.

    PubMed

    Wilgen, Urs; Pretorius, Carel J; Gous, Rehna S; Martin, Cameron; Hale, Vincent J; Ungerer, Jacobus P J

    2014-09-01

    Point-of-care testing for β-hCG has been widely advocated to allow rapid diagnosis/exclusion of pregnancy in the emergency department. A quantitative blood β-hCG assay has the additional benefit of being able to monitor the viability of pregnancy, using serial measurements, to determine the appropriate expected increase in β-hCG levels over time (e.g. ectopic pregnancy), and aiding in determining if an intrauterine gestational sac should be visible on sonographic imaging. Evaluation of the newly released Abbott i-STAT β-hCG point-of-care assay with the Beckman Coulter β-hCG laboratory assay in use. Whole blood, plasma and serum samples with a wide range of β-hCG concentrations were analysed by both methods. The Abbott I-STAT β-hCG compares favourably, can be performed on heparinised whole blood, plasma and serum, and shows acceptable accuracy and precision. However a hook effect at elevated β-hCG was shown in gestational trophoblastic disease as well as normal pregnancies. The i-STAT β-hCG performs acceptably in its intended use in the early detection of pregnancy, but results should always be interpreted within the clinical context, as a hook effect may occur. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  15. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  16. Plate convergence at the westernmost Philippine Sea Plate

    NASA Astrophysics Data System (ADS)

    Wu, Wen-Nan; Hsu, Shu-Kun; Lo, Chung-Liang; Chen, How-Wei; Ma, Kuo-Fong

    2009-03-01

    To understand the convergent characteristics of the westernmost plate boundary between the Philippine Sea Plate (PSP) and Eurasian Plate (EP), we have calculated the stress states of plate motion by focal mechanisms. Cataloged by the Harvard centroid moment tensor solutions (Harvard CMT) and the Broadband Array in Taiwan (BATS) moment tensor, 251 focal mechanisms are used to determine the azimuths of the principal stress axes. We first used all the data to derive the mean stress tensor of the study area. The inversion result shows that the stress regime has a maximum compression along the direction of azimuth N299°. This result is consistent with the general direction of the rigid plate motion between the PSP and EP in the study area. In order to understand the spatial variation of the regional stress pattern, we divided the study area into six sub-areas (blocks A to F) based on the feature of the free-air gravity anomaly. We compare the compressive directions obtained from the stress inversion with the plate motions calculated by the Euler pole and the Global Positioning System (GPS) analysis. As a result, the azimuth of the maximum stress axis, σ1, generally agrees with the directions of the theoretical plate motion and GPS velocity vectors except block C (Lanhsu region) and block F (Ilan plain region). The discrepancy of convergent direction near the Ilan plain region is probably caused by the rifting of the Okinawa Trough. The deviation of the σ1 azimuth in the Lanhsu region could be attributed to a southwestward extrusion of the Luzon Arc (LA) block between 21°N and 22°N whose northern boundary may be associated with the right-lateral NE-SW trending fault (i.e. Huatung Fault, HF) along the Taitung Canyon. Comparing the σ1 stress patterns between block C and block D, great strain energy along HF may not be completely released yet. Alternatively, the upper crust of block C may significantly have decoupled from its lower crust or uppermost mantle.

  17. Automation Hooks Architecture Trade Study for Flexible Test Orchestration

    NASA Technical Reports Server (NTRS)

    Lansdowne, Chatwin A.; Maclean, John R.; Graffagnino, Frank J.; McCartney, Patrick A.

    2010-01-01

    We describe the conclusions of a technology and communities survey supported by concurrent and follow-on proof-of-concept prototyping to evaluate feasibility of defining a durable, versatile, reliable, visible software interface to support strategic modularization of test software development. The objective is that test sets and support software with diverse origins, ages, and abilities can be reliably integrated into test configurations that assemble and tear down and reassemble with scalable complexity in order to conduct both parametric tests and monitored trial runs. The resulting approach is based on integration of three recognized technologies that are currently gaining acceptance within the test industry and when combined provide a simple, open and scalable test orchestration architecture that addresses the objectives of the Automation Hooks task. The technologies are automated discovery using multicast DNS Zero Configuration Networking (zeroconf), commanding and data retrieval using resource-oriented Restful Web Services, and XML data transfer formats based on Automatic Test Markup Language (ATML). This open-source standards-based approach provides direct integration with existing commercial off-the-shelf (COTS) analysis software tools.

  18. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  19. Biomechanical comparison of anterior cervical plating and combined anterior/lateral mass plating.

    PubMed

    Adams, M S; Crawford, N R; Chamberlain, R H; Bse; Sonntag, V K; Dickman, C A

    2001-01-01

    Previous studies showed anterior plates of older design to be inadequate for stabilizing the cervical spine in all loading directions. No studies have investigated enhancement in stability obtained by combining anterior and posterior plates. To determine which modes of loading are stabilized by anterior plating after a cervical burst fracture and to determine whether adding posterior plating further significantly stabilizes the construct. A repeated-measures in vitro biomechanical flexibility experiment was performed to investigate how surgical destabilization and subsequent addition of hardware components alter spinal stability. Six human cadaveric specimens were studied. Angular range of motion (ROM) and neutral zone (NZ) were quantified during flexion, extension, lateral bending, and axial rotation. Nonconstraining, nondestructive torques were applied while recording three-dimensional motion optoelectronically. Specimens were tested intact, destabilized by simulated burst fracture with posterior distraction, plated anteriorly with a unicortical locking system, and plated with a combined anterior/posterior construct. The anterior plate significantly (p<.05) reduced the ROM relative to normal in all modes of loading and significantly reduced the NZ in flexion and extension. Addition of the posterior plates further significantly reduced the ROM in all modes of loading and reduced the NZ in lateral bending. Anterior plating systems are capable of substantially stabilizing the cervical spine in all modes of loading after a burst fracture. The combined approach adds significant stability over anterior plating alone in treating this injury but may be unnecessary clinically. Further study is needed to assess the added clinical benefits of the combined approach and associated risks.

  20. The effect of plate-scale rheology and plate interactions on intraplate seismicity

    NASA Astrophysics Data System (ADS)

    So, Byung-Dal; Capitanio, Fabio A.

    2017-11-01

    We use finite element modeling to investigate on the stress loading-unloading cycles and earthquakes occurrence in the plate interiors, resulting from the interactions of tectonic plates along their boundary. We model a visco-elasto-plastic plate embedding a single or multiple faults, while the tectonic stress is applied along the plate boundary by an external loading visco-elastic plate, reproducing the tectonic setting of two interacting lithospheres. Because the two plates deform viscously, the timescale of stress accumulation and release on the faults is self-consistently determined, from the boundary to the interiors, and seismic recurrence is an emerging feature. This approach overcomes the constraints on recurrence period imposed by stress (stress-drop) and velocity boundary conditions, while here it is unconstrained. We illustrate emerging macroscopic characteristics of this system, showing that the seismic recurrence period τ becomes shorter as Γ and Θ decreases, where Γ =ηI /ηL, the viscosity ratio of the viscosities of the internal fault-embedded to external loading plates, respectively, and Θ =σY /σL the stress ratio of the elastic limit of the fault to far-field loading stress. When the system embeds multiple, randomly distributed faults, stress transfer results in recurrence period deviations, however the time-averaged recurrence period of each fault show the same dependence on Γ and Θ, illustrating a characteristic collective behavior. The control of these parameters prevails even when initial pre-stress was randomly assigned in terms of the spatial arrangement and orientation on the internal plate, mimicking local fluctuations. Our study shows the relevance of macroscopic rheological properties of tectonic plates on the earthquake occurrence in plate interiors, as opposed to local factors, proposing a viable model for the seismic behavior of continent interiors in the context of large-scale, long-term deformation of interacting tectonic

  1. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  2. What can numerical computation do for the history of science? (a study of an orbit drawn by Newton in a letter to Hooke)

    NASA Astrophysics Data System (ADS)

    Cardozo Dias, Penha Maria; Stuchi, T. J.

    2013-11-01

    In a letter to Robert Hooke, Isaac Newton drew the orbit of a mass moving under a constant attracting central force. The drawing of the orbit may indicate how and when Newton developed dynamic categories. Some historians claim that Newton used a method contrived by Hooke; others that he used some method of curvature. We prove that Hooke’s method is a second-order symplectic area-preserving algorithm, and the method of curvature is a first-order algorithm without special features; then we integrate the Hamiltonian equations. Integration by the method of curvature can also be done, exploring the geometric properties of curves. We compare three methods: Hooke’s method, the method of curvature and a first-order method. A fourth-order algorithm sets a standard of comparison. We analyze which of these methods best explains Newton’s drawing.

  3. Biomechanical analysis of a novel hook-screw technique for C1-2 stabilization.

    PubMed

    Reis, Marco Túlio; Nottmeier, Eric W; Reyes, Phillip M; Baek, Seungwon; Crawford, Neil R

    2012-09-01

    The Food and Drug Administration has not cleared the following medical devices for the use described in this study. The following medical devices are being discussed for an off-label use: cervical lateral mass screws. As an alternative for cases in which the anatomy and spatial relationship between C-2 and a vertebral artery precludes insertion of C-2 pedicle/pars or C1-2 transarticular screws, a technique that includes opposing laminar hooks (claw) at C-2 combined with C-1 lateral mass screws may be used. The biomechanical stability of this alternate technique was compared with that of a standard screw-rod technique in vitro. Flexibility tests were performed in 7 specimens (occiput to C-3) in the following 6 different conditions: 1) intact; 2) after creating instability and attaching a posterior cable/graft at C1-2; 3) after removing the graft and attaching a construct comprising C-1 lateral mass screws and C-2 laminar claws; 4) after reattaching the posterior cable-graft at C1-2 (posterior hardware still in place); 5) after removing the posterior cable-graft and laminar hooks and placing C-2 pedicle screws interconnected to C-1 lateral mass screws via rod; and 6) after reattaching the posterior cable-graft at C1-2 (screw-rod construct still in place). All types of stabilization significantly reduced the range of motion, lax zone, and stiff zone compared with the intact condition. There was no significant biomechanical difference in terms of range of motion or lax zone between the screw-rod construct and the screw-claw-rod construct in any direction of loading. The screw-claw-rod technique restricts motion much like the standard Harms technique, making it an acceptable alternative technique when aberrant arterial anatomy precludes the placement of C-2 pars/pedicle screws or C1-2 transarticular screws.

  4. Hooking injury, physiological status and short-term mortality of juvenile lemon sharks (Negaprion bevirostris) following catch-and-release recreational angling

    PubMed Central

    Danylchuk, Andy J.; Suski, Cory D.; Mandelman, John W.; Murchie, Karen J.; Haak, Christopher R.; Brooks, Annabelle M. L.; Cooke, Steven J.

    2014-01-01

    Sport fishing for sharks, including fishing with the intent to release, is becoming more prevalent within the recreational angling community. Common targets of recreational anglers are juvenile lemon sharks (Negaprion brevirostris) that frequent shallow tropical nearshore habitats. In this study, we captured 32 juvenile lemon sharks (530–875 mm total length) with conventional angling gear (i.e. spinning rods, dead fish bait and 5/0 barbed circle hooks) from the coastal waters of Eleuthera, The Bahamas, to determine the consequences of capture for individual sharks. Each shark was examined for hooking injuries, blood sampled to quantify physiological disturbance, assessed for reflex impairment and then monitored to assess post-release behaviour and mortality. Four sharks (12.5%) died following release during the 15 min tracking period. Principal components (PC) analysis revealed four axes describing 66.5% of the variance for blood physiology parameters, total length and water temperature. The PC1 and PC3 scores, characterized by positive factor loadings for indicators of exercise-induced stress and blood ion concentrations, respectively, were significantly related to fight time but were not associated with short-term mortality. Short-term mortality was significantly related to factor scores for PC4 that loaded heavily for water temperature and total length. Ten sharks (31%) exhibited impaired reflexes, with loss of bite reflex being most prevalent. Sharks that died had the following characteristics: (i) they had two or more impaired reflexes; (ii) they were hooked in the basihyal; (iii) they exhibited no movement after the initial bout of directional swimming; and (iv) they experienced high water temperatures (i.e. >31°C). Collectively, these results indicate that for juvenile lemon sharks inhabiting tropical flats, fight time can influence the degree of physiological disturbance, while water temperature contributes to the likelihood of survival

  5. Hooking injury, physiological status and short-term mortality of juvenile lemon sharks (Negaprion bevirostris) following catch-and-release recreational angling.

    PubMed

    Danylchuk, Andy J; Suski, Cory D; Mandelman, John W; Murchie, Karen J; Haak, Christopher R; Brooks, Annabelle M L; Cooke, Steven J

    2014-01-01

    Sport fishing for sharks, including fishing with the intent to release, is becoming more prevalent within the recreational angling community. Common targets of recreational anglers are juvenile lemon sharks (Negaprion brevirostris) that frequent shallow tropical nearshore habitats. In this study, we captured 32 juvenile lemon sharks (530-875 mm total length) with conventional angling gear (i.e. spinning rods, dead fish bait and 5/0 barbed circle hooks) from the coastal waters of Eleuthera, The Bahamas, to determine the consequences of capture for individual sharks. Each shark was examined for hooking injuries, blood sampled to quantify physiological disturbance, assessed for reflex impairment and then monitored to assess post-release behaviour and mortality. Four sharks (12.5%) died following release during the 15 min tracking period. Principal components (PC) analysis revealed four axes describing 66.5% of the variance for blood physiology parameters, total length and water temperature. The PC1 and PC3 scores, characterized by positive factor loadings for indicators of exercise-induced stress and blood ion concentrations, respectively, were significantly related to fight time but were not associated with short-term mortality. Short-term mortality was significantly related to factor scores for PC4 that loaded heavily for water temperature and total length. Ten sharks (31%) exhibited impaired reflexes, with loss of bite reflex being most prevalent. Sharks that died had the following characteristics: (i) they had two or more impaired reflexes; (ii) they were hooked in the basihyal; (iii) they exhibited no movement after the initial bout of directional swimming; and (iv) they experienced high water temperatures (i.e. >31°C). Collectively, these results indicate that for juvenile lemon sharks inhabiting tropical flats, fight time can influence the degree of physiological disturbance, while water temperature contributes to the likelihood of survival

  6. Reconstructing plate motion paths where plate tectonics doesn't strictly apply

    NASA Astrophysics Data System (ADS)

    Handy, M. R.; Ustaszewski, K.

    2012-04-01

    The classical approach to reconstructing plate motion invokes the assumption that plates are rigid and therefore that their motions can be described as Eulerian rotations on a spherical Earth. This essentially two-dimensional, map view of plate motion is generally valid for large-scale systems, but is not practicable for small-scale tectonic systems in which plates, or significant parts thereof, deform on time scales approaching the duration of their motion. Such "unplate-like" (non-rigid) behaviour is common in systems with a weak lithosphere, for example, in Mediterranean-type settings where (micro-)plates undergo distributed deformation several tens to hundreds of km away from their boundaries. The motion vector of such anomalous plates can be quantified by combining and comparing information from two independent sources: (1) Balanced cross sections that are arrayed across deformed zones (orogens, basins) and provide estimates of crustal shortening and/or extension. Plate motion is then derived by retrodeforming the balanced sections in a stepwise fashion from external to internal parts of mountain belts, then applying these estimates as successive retrotranslations of points on stable parts of the upper plate with respect to a chosen reference frame on the lower plate. This approach is contingent on using structural markers with tight age constraints, for example, depth-sensitive metamorphic mineral parageneses and syn-orogenic sediments with known paleogeographic provenance; (2) Geophysical images of 3D subcrustal structure, especially of the MOHO and the lithospheric mantle in the vicinity of the deformed zones. In the latter case, travel-time seismic tomography of velocity anomalies can be used to identify subducted lithospheric slabs that extend downwards from the zones of crustal shortening to the mantle transitional zone and beyond. Synthesizing information from these two sources yields plate motion paths whose validity can be tested by the degree of

  7. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  8. [Fracture of the diaphyseal radius during Cyr wheel practice - an uncommon injury of wheel gymnastics].

    PubMed

    Kauther, M D; Rummel, S; Hussmann, B; Lendemans, S; Nast-Kolb, D; Wedemeyer, C

    2011-12-01

    The cyr wheel is a modified gymnastic wheel with only one ring that can lead to extreme forces on the gymnast. We report on a distal radius shaft fracture (AO 22 A 2.1) and a fracture of the styloid process of the ulna that occurred after holding on to a slipping Cyr wheel and exposition to high pressure on the lower arm. The fracture was fixed by screws and a plate. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Reliability assessment of different plate theories for elastic wave propagation analysis in functionally graded plates.

    PubMed

    Mehrkash, Milad; Azhari, Mojtaba; Mirdamadi, Hamid Reza

    2014-01-01

    The importance of elastic wave propagation problem in plates arises from the application of ultrasonic elastic waves in non-destructive evaluation of plate-like structures. However, precise study and analysis of acoustic guided waves especially in non-homogeneous waveguides such as functionally graded plates are so complicated that exact elastodynamic methods are rarely employed in practical applications. Thus, the simple approximate plate theories have attracted much interest for the calculation of wave fields in FGM plates. Therefore, in the current research, the classical plate theory (CPT), first-order shear deformation theory (FSDT) and third-order shear deformation theory (TSDT) are used to obtain the transient responses of flexural waves in FGM plates subjected to transverse impulsive loadings. Moreover, comparing the results with those based on a well recognized hybrid numerical method (HNM), we examine the accuracy of the plate theories for several plates of various thicknesses under excitations of different frequencies. The material properties of the plate are assumed to vary across the plate thickness according to a simple power-law distribution in terms of volume fractions of constituents. In all analyses, spatial Fourier transform together with modal analysis are applied to compute displacement responses of the plates. A comparison of the results demonstrates the reliability ranges of the approximate plate theories for elastic wave propagation analysis in FGM plates. Furthermore, based on various examples, it is shown that whenever the plate theories are used within the appropriate ranges of plate thickness and frequency content, solution process in wave number-time domain based on modal analysis approach is not only sufficient but also efficient for finding the transient waveforms in FGM plates. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A 34-Week Size Uterus with a Complete Hydatidiform Mole: Hook Effect and Severe Anemia with No Vaginal Bleeding.

    PubMed

    McLaren, Rodney; Bayya, Vijaya; Irani, Mohamad

    2018-01-01

    Complete hydatidiform mole is an abnormal pregnancy that usually presents with vaginal bleeding and markedly elevated serum ß-hCG levels. We report a rare case of complete hydatidiform mole occurring in a 16-year-old nulligravid who presented with a 34-week size uterus and a relatively low serum ß-hCG level (722 IU/L)-likely related to the "hook effect"-and severe anemia (hemoglobin: 6.1 g/dL) despite the absence of vaginal bleeding. She also reported right flank pain and was diagnosed with moderate right hydronephrosis owing to the compression exerted by the enlarged uterus on the right ureter. The patient received a total of 6 units of packed red blood cells and was managed by dilation and evacuation followed by serial monitoring of serum ß-hCG levels. Therefore, complete mole can present with symptoms related to an enlarged uterus and severe anemia before the occurrence of vaginal bleeding. It is also important to note that a negative urine pregnancy test or relatively low serum ß-hCG level should prompt repeating the measurement on diluted sample to prevent the "hook effect."

  11. Plating To Reinforce Welded Joints

    NASA Technical Reports Server (NTRS)

    Otousa, J. E.

    1982-01-01

    Electrodeposition used to strengthen welded joints gouged, nicked, or suffered other mechanical damage. Plating cell, typically of acrylic plastic such as poly (Methylmetacrylate), is assembled around part to be plated. Areas not to be plated are masked with plater's tape. Weld area is plated in standard nickel-plating process.

  12. Mantle convection with plates and mobile, faulted plate margins.

    PubMed

    Zhong, S; Gurnis, M

    1995-02-10

    A finite-element formulation of faults has been incorporated into time-dependent models of mantle convection with realistic rheology, continents, and phase changes. Realistic tectonic plates naturally form with self-consistent coupling between plate and mantle dynamics. After the initiation of subduction, trenches rapidly roll back with subducted slabs temporarily laid out along the base of the transition zone. After the slabs have penetrated into the lower mantle, the velocity of trench migration decreases markedly. The inhibition of slab penetration into the lower mantle by the 670-kilometer phase change is greatly reduced in these models as compared to models without tectonic plates.

  13. Philosophy of experiment in early modern England: the case of Bacon, Boyle and Hooke.

    PubMed

    Anstey, Peter R

    2014-01-01

    Serious philosophical reflection on the nature of experiment began in earnest in the seventeenth century. This paper expounds the most influential philosophy of experiment in seventeenth-century England, the Bacon-Boyle-Hooke view of experiment. It is argued that this can only be understood in the context of the new experimental philosophy practised according to the Baconian theory of natural history. The distinctive typology of experiments of this view is discussed, as well as its account of the relation between experiment and theory. This leads into an assessment of other recent discussions of early modern experiment, namely, those of David Gooding, Thomas Kuhn, J.E. Tiles and Peter Dear.

  14. Behaviour of Plate Anchorage in Plate-Reinforced Composite Coupling Beams

    PubMed Central

    Lam, W. Y.; Li, Lingzhi; Su, R. K. L.; Pam, H. J.

    2013-01-01

    As a new alternative design, plate-reinforced composite (PRC) coupling beam achieves enhanced strength and ductility by embedding a vertical steel plate into a conventionally reinforced concrete (RC) coupling beam. Based on a nonlinear finite element model developed in the authors' previous study, a parametric study presented in this paper has been carried out to investigate the influence of several key parameters on the overall performance of PRC coupling beams. The effects of steel plate geometry, span-to-depth ratio of beams, and steel reinforcement ratios at beam spans and in wall regions are quantified. It is found that the anchorage length of the steel plate is primarily controlled by the span-to-depth ratio of the beam. Based on the numerical results, a design curve is proposed for determining the anchorage length of the steel plate. The load-carrying capacity of short PRC coupling beams with high steel ratio is found to be controlled by the steel ratio of wall piers. The maximum shear stress of PRC coupling beams should be limited to 15 MPa. PMID:24288465

  15. Economic Analysis of Anatomic Plating Versus Tubular Plating for the Treatment of Fibula Fractures.

    PubMed

    Chang, Gerard; Bhat, Suneel B; Raikin, Steven M; Kane, Justin M; Kay, Andrew; Ahmad, Jamal; Pedowitz, David I; Krieg, James

    2018-03-01

    Ankle fractures are among the most common injuries requiring operative management. Implant choices include one-third tubular plates and anatomically precontoured plates. Although cadaveric studies have not revealed biomechanical differences between various plate constructs, there are substantial cost differences. This study sought to characterize the economic implications of implant choice. A retrospective review was undertaken of 201 consecutive patients with operatively treated OTA type 44B and 44C ankles. A Nationwide Inpatient Sample query was performed to estimate the incidence of ankle fractures requiring fibular plating, and a Monte Carlo simulation was conducted with the estimated at-risk US population for associated plate-specific costs. The authors estimated an annual incidence of operatively treated ankle fractures in the United States of 59,029. The average cost was $90.86 (95% confidence interval, $90.84-$90.87) for a one-third tubular plate vs $746.97 (95% confidence interval, $746.55-$747.39) for an anatomic plate. Across the United States, use of only one-third tubular plating over anatomic plating would result in statistically significant savings of $38,729,517 (95% confidence interval, $38,704,773-$38,754,261; P<.0001). General use of one-third tubular plating instead of anatomic plating whenever possible for fibula fractures could result in cost savings of up to nearly $40 million annually in the United States. Unless clinically justifiable on a per-case basis, or until the advent of studies showing substantial clinical benefit, there currently is no reason for the increased expense from widespread use of anatomic plating for fractures amenable to one-third tubular plating. [Orthopedics. 2018; 41(2):e252-e256.]. Copyright 2018, SLACK Incorporated.

  16. Inverse methods-based estimation of plate coupling in a plate motion model governed by mantle flow

    NASA Astrophysics Data System (ADS)

    Ratnaswamy, V.; Stadler, G.; Gurnis, M.

    2013-12-01

    Plate motion is primarily controlled by buoyancy (slab pull) which occurs at convergent plate margins where oceanic plates undergo deformation near the seismogenic zone. Yielding within subducting plates, lateral variations in viscosity, and the strength of seismic coupling between plate margins likely have an important control on plate motion. Here, we wish to infer the inter-plate coupling for different subduction zones, and develop a method for inferring it as a PDE-constrained optimization problem, where the cost functional is the misfit in plate velocities and is constrained by the nonlinear Stokes equation. The inverse models have well resolved slabs, plates, and plate margins in addition to a power law rheology with yielding in the upper mantle. Additionally, a Newton method is used to solve the nonlinear Stokes equation with viscosity bounds. We infer plate boundary strength using an inexact Gauss-Newton method with line search for backtracking. Each inverse model is applied to two simple 2-D scenarios (each with three subduction zones), one with back-arc spreading and one without. For each case we examine the sensitivity of the inversion to the amount of surface velocity used: 1) full surface velocity data and 2) surface velocity data simplified using a single scalar average (2-D equivalent to an Euler pole) for each plate. We can recover plate boundary strength in each case, even in the presence of highly nonlinear flow with extreme variations in viscosity. Additionally, we ascribe an uncertainty in each plate's velocity and perform an uncertainty quantification (UQ) through the Hessian of the misfit in plate velocities. We find that as plate boundaries become strongly coupled, the uncertainty in the inferred plate boundary strength decreases. For very weak, uncoupled subduction zones, the uncertainty of inferred plate margin strength increases since there is little sensitivity between plate margin strength and plate velocity. This result is significant

  17. 46 CFR 160.060-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... instruments of closure for buoyant vests. 160.060-3a Section 160.060-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Polyethylene Foam, Adult and Child § 160.060-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests...

  18. 46 CFR 160.060-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... instruments of closure for buoyant vests. 160.060-3a Section 160.060-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Polyethylene Foam, Adult and Child § 160.060-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests...

  19. 46 CFR 160.060-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... instruments of closure for buoyant vests. 160.060-3a Section 160.060-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Polyethylene Foam, Adult and Child § 160.060-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests...

  20. 46 CFR 160.060-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... instruments of closure for buoyant vests. 160.060-3a Section 160.060-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Polyethylene Foam, Adult and Child § 160.060-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests...

  1. Fibonacci-like zone plate

    NASA Astrophysics Data System (ADS)

    Cheng, Shubo; Liu, Mengsi; Xia, Tian; Tao, Shaohua

    2018-06-01

    We present a new family of diffractive lenses, Fibonacci-like zone plates, generated with a modified Fibonacci sequence. The focusing properties and the evolution of transverse diffraction pattern for the Fibonacci-like zone plates have been analytically investigated both theoretically and experimentally and compared with the corresponding Fresnel zone plates of the same resolution. The results demonstrate that the Fibonacci-like zone plates possess the self-similar property and the multifocal behavior. Furthermore, the Fibonacci-like zone plate beams are found to possess the self-reconstruction property, and would be promising for 3D optical tweezers, laser machining, and optical imaging.

  2. Plate on plate osteosynthesis for the treatment of nonhealed periplate fractures.

    PubMed

    Arealis, Georgios; Nikolaou, Vassilios S; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation.

  3. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  4. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  5. Nuclear reactor alignment plate configuration

    DOEpatents

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  6. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  7. 46 CFR 160.052-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... instruments of closure for buoyant vests. 160.052-3a Section 160.052-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Plastic Foam, Adult and Child § 160.052-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  8. 46 CFR 160.047-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... instruments of closure for buoyant vests. 160.047-3a Section 160.047-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Kapok or Fibrous Glass, Adult and Child § 160.047-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  9. 46 CFR 160.047-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... instruments of closure for buoyant vests. 160.047-3a Section 160.047-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Kapok or Fibrous Glass, Adult and Child § 160.047-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  10. 46 CFR 160.047-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... instruments of closure for buoyant vests. 160.047-3a Section 160.047-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Kapok or Fibrous Glass, Adult and Child § 160.047-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  11. 46 CFR 160.052-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... instruments of closure for buoyant vests. 160.052-3a Section 160.052-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Plastic Foam, Adult and Child § 160.052-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  12. 46 CFR 160.047-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... instruments of closure for buoyant vests. 160.047-3a Section 160.047-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Kapok or Fibrous Glass, Adult and Child § 160.047-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  13. 46 CFR 160.052-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... instruments of closure for buoyant vests. 160.052-3a Section 160.052-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Plastic Foam, Adult and Child § 160.052-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  14. 46 CFR 160.052-3a - Materials-Dee ring and snap hook assemblies and other instruments of closure for buoyant vests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... instruments of closure for buoyant vests. 160.052-3a Section 160.052-3a Shipping COAST GUARD, DEPARTMENT OF... LIFESAVING EQUIPMENT Specification for a Buoyant Vest, Unicellular Plastic Foam, Adult and Child § 160.052-3a Materials—Dee ring and snap hook assemblies and other instruments of closure for buoyant vests. (a...

  15. Portable Plating System

    NASA Technical Reports Server (NTRS)

    Flores, R.

    1984-01-01

    Plating system mounted on portable cart includes 30-gallon (23.5 liter) electrolyte tank, filler pump, heaters, replenishing anodes, plating rectifiers and tank rectifier to continously remove contaminants.

  16. The Importance of Lower Mantle Structure to Plate Stresses and Plate Motions

    NASA Astrophysics Data System (ADS)

    Holt, W. E.; Wang, X.; Ghosh, A.

    2016-12-01

    Plate motions and plate stresses are widely assumed as the surface expression of mantle convection. The generation of plate tectonics from mantle convection has been studied for many years. Lithospheric thickening (or ridge push) and slab pull forces are commonly accepted as the major driving forces for the plate motions. However, the importance of the lower mantle to plate stresses and plate motions remains less clear. Here, we use the joint modeling of lithosphere and mantle dynamics approach of Wang et al. (2015) to compute the tractions originating from deeper mantle convection and follow the method of Ghosh et al. (2013) to calculate gravitational potential energy per unit area (GPE) based on Crust 1.0 (Laske et al., 2013). Absolute values of deviatoric stresses are determined by the body force distributions (GPE gradients and traction magnitudes applied at the base of the lithosphere). We use the same relative viscosity model that Ghosh et al. (2013) used, and we solve for one single adjustable scaling factor that multiplies the entire relative viscosity field to provide absolute values of viscosity throughout the lithosphere. This distribution of absolute values of lithosphere viscosities defines the magnitudes of surface motions. In this procedure, the dynamic model first satisfies the internal constraint of no-net-rotation of motions. The model viscosity field is then scaled by the single factor until we achieve a root mean square (RMS) minimum between computed surface motions and the kinematic no-net-rotation (NNR) model of Kreemer et al. (2006). We compute plate stresses and plate motions from recently published global tomography models (over 70 based on Wang et al., 2015). We find that RMS misfits are significantly reduced when details of lower mantle structure from the latest tomography models are added to models that contain only upper and mid-mantle density distributions. One of the key reasons is that active upwelling from the Large Low Shear

  17. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  18. Mechanical stress in plates for bridging reconstruction mandibular defects and purposes of double plate reinforcement.

    PubMed

    Hoefert, Sebastian; Taier, Roberto

    2018-05-01

    To evaluate the biomechanical performance of a commercially available bridging plate (2.4) as well as screws and bone simulating the reconstruction of hemimandibular defects and to indicate alternatives of reinforcement to prevent plate fractures either by strength or fatigue. Two common hemimandibular defects are investigated using computed finite element analysis (FEA) approach. Simplified and refined computational models are developed for the geometry of the screw. Conditions of non-locking and locking plate-screw interfaces are considered. Static loads of 120 N are applied. Von Mises stresses and fatigue are calculated. As reinforcement, a second complete or partial plate is placed onto the original plate. Results demonstrate that reconstruction plates are often subjected to excessive stress that may lead to fracture either by strength or by fatigue. An attached complete or partial second plate is able to reduce stress in the plate, in screws and bone so that stress remains below the allowable limit of the materials. A simplified technique of attaching a whole or sectioned second plate onto the original plate can reduce the stress calculated and may reduce the frequency of plate fractures for the patient's comfort, security and financial savings. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Fuel cell cooler-humidifier plate

    DOEpatents

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  20. 77 FR 13510 - Pacific Cod by Catcher Vessels Less Than 50 Feet (15.2 Meters) Length Overall Using Hook-and-Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-07

    .... 101126522-0640-2] RIN 0648-XB062 Pacific Cod by Catcher Vessels Less Than 50 Feet (15.2 Meters) Length... (CVs) less than 50 feet (15.2 meters (m)) in length overall (LOA) using hook-and-line gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to CVs less than 50 feet (15.2...

  1. Production of polyimide ceria nanocomposites by development of molecular hook technology in nano-sonochemistry.

    PubMed

    Hatami, Mehdi

    2018-06-01

    Poly(amic acid), the precursor of polyimide (PI), was used for the preparation of PI/CeO 2 nanocomposites (NC)s by ultrasonic assisted technique via insertion of the surface modified CeO 2 nanoparticles (NP)s into PI matrix. In the preparation stages, in the first, the modifications of CeO 2 NPs by using hexadecyltrimethoxysilane (HDTMS) as a binder were targeted using ultrasonic waves. In the second step, newly designed PI structure was formed from the sonochemical imidization process as a molecular hook. In this step two different reactions were occurred. The acetic acid elimination reaction in the main chain of macromolecule, and the acetylation reaction in the side chains of poly(amic acid) were accomplished. By acetylation process the hook structure was created for trapping of the modified nanoparticles. In the final step the preparation of PI NCs were achieved by sonochemical process. The structural and thermal properties of pure PI and PI/CeO 2 NCs were studied by several techniques such as fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance spectroscopy (NMR), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM), X-ray diffraction (XRD), and thermal analyses. FT-IR and 1 H NMR spectra confirmed the success in preparation of PI matrix. The FE-SEM, TEM, and AFM analyses showed the uniform distribution of CeO 2 NPs in PI matrix. The XRD patterns of NCs show the presence of crystalline CeO 2 NPs in amorphous PI matrix. The thermal analysis results reveal that, with increases in the content of CeO 2 NPs in PI matrix, the thermally stability factors of samples were improved. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Current plate velocities relative to the hotspots incorporating the NUVEL-1 global plate motion model

    NASA Technical Reports Server (NTRS)

    Gripp, Alice E.; Gordon, Richard G.

    1990-01-01

    The NUVEL-1 model of current global relative plate velocities is presently incorporated into HS2-NUVEL1, a global model for plate velocities relative to hotspots; the results thus obtained are compared with those of the AM1-2 model of hotspot-relative plate velocities. While there are places in which plate velocities relative to the hotspots differ between HS2-NUVEL1 and AM1-2 by tens of degrees in direction and 15 mm/yr in speed, the hotspot Euler vectors differ with 95 percent confidence only for the Arabian and Indian plates. Plates attached to subducting slabs move faster relative to the hotspots than do plates without slabs.

  3. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-04

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction.

  4. Absolute Plate Velocities from Seismic Anisotropy

    NASA Astrophysics Data System (ADS)

    Kreemer, Corné; Zheng, Lin; Gordon, Richard

    2015-04-01

    The orientation of seismic anisotropy inferred beneath plate interiors may provide a means to estimate the motions of the plate relative to the sub-asthenospheric mantle. Here we analyze two global sets of shear-wave splitting data, that of Kreemer [2009] and an updated and expanded data set, to estimate plate motions and to better understand the dispersion of the data, correlations in the errors, and their relation to plate speed. We also explore the effect of using geologically current plate velocities (i.e., the MORVEL set of angular velocities [DeMets et al. 2010]) compared with geodetically current plate velocities (i.e., the GSRM v1.2 angular velocities [Kreemer et al. 2014]). We demonstrate that the errors in plate motion azimuths inferred from shear-wave splitting beneath any one tectonic plate are correlated with the errors of other azimuths from the same plate. To account for these correlations, we adopt a two-tier analysis: First, find the pole of rotation and confidence limits for each plate individually. Second, solve for the best fit to these poles while constraining relative plate angular velocities to consistency with the MORVEL relative plate angular velocities. The SKS-MORVEL absolute plate angular velocities (based on the Kreemer [2009] data set) are determined from the poles from eight plates weighted proportionally to the root-mean-square velocity of each plate. SKS-MORVEL indicates that eight plates (Amur, Antarctica, Caribbean, Eurasia, Lwandle, Somalia, Sundaland, and Yangtze) have angular velocities that differ insignificantly from zero. The net rotation of the lithosphere is 0.25±0.11° Ma-1 (95% confidence limits) right-handed about 57.1°S, 68.6°E. The within-plate dispersion of seismic anisotropy for oceanic lithosphere (σ=19.2° ) differs insignificantly from that for continental lithosphere (σ=21.6° ). The between-plate dispersion, however, is significantly smaller for oceanic lithosphere (σ=7.4° ) than for continental

  5. Highly conductive composites for fuel cell flow field plates and bipolar plates

    DOEpatents

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  6. Anatomic fit of six different radial head plates: comparison of precontoured low-profile radial head plates.

    PubMed

    Burkhart, Klaus Josef; Nowak, Tobias E; Kim, Yoon-Joo; Rommens, Pol M; Müller, Lars P

    2011-04-01

    Bulky implants may lead to symptomatic soft tissue irritation after open reduction and internal fixation of radial head and neck fractures. The purpose of our study was to compare the anatomic fit of precontoured radial head plates. We stripped 22 embalmed human cadaveric radiuses of soft tissues. We investigated 6 radial head plates: (1) the Medartis radial head buttress plate (MBP), (2) the Medartis radial head rim plate (MRP), (3) the Synthes radial neck plate (SNP), (4) the Synthes radial head plate (SHP), (5) the Acumed radial head plate (AHP), and (6) the Wright radial head plate (WHP). Each plate was applied to each radial head at the place of best fit within the safe zone. We tested 4 parameters of anatomic fit: (1) plate-to-bone distance, (2) plate contact judged by 3 different observers, (3) pin-subchondral zone distance, and (4) plate-to-bone contact after adjustment of the plates. The MBP and MRP showed the lowest profile by objective measurements, the SNP and AHP had a moderate profile, and the SHP and WHP demonstrated the bulkiest profile. The subjective assessments also demonstrated the best fit for the MBP, a good fit for the SNP, a moderate fit for the MRP and AHP, and a poor fit for the SHP and WHP. The MBP, MRP, and AHP could always provide pin-subchondral zone contact, unlike the SHP, SNP, and WHP. After bending, significant improvement of plate-to-bone distance could only be seen for the MBP, MRP, and WHP. The ranking among plates remained the same except for the WHP, which showed a significantly lower plate-to-bone distance than the SHP. Currently available radial head implants are heterogeneous. The MBP and MRP showed the lowest profile and best anatomic fit. Owing to the complex radial head anatomy, to date there is no one radial head plate that perfectly fits all radial heads. Conformance of existing plates to the radial head and neck is not perfect. Careful plate selection and modification, when necessary, may minimize interference of this

  7. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  8. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  9. Potential Usefulness of the Kampo Medicine Yokukansan, Containing Uncaria Hook, for Paediatric Emotional and Behavioural Disorders: A Case Series

    PubMed Central

    2013-01-01

    Background. Paediatric emotional and behavioural disorders (EBD) are relatively common diseases. Although nonpharmacologic and pharmacologic treatments are utilized in these cases, it is sometimes difficult to manage the symptoms of EBD. Historically, Uncaria hook has been used for treating nighttime crying and convulsions in children. Recent clinical studies have demonstrated that the Kampo medicine Yokukansan (YKS), which contains Uncaria hook, is efficacious for behaviour disorders in Alzheimer's disease patients. Herein, we investigated the clinical efficacy and safety of YKS in a series of cases with paediatric EBD. Patients and Methods. We retrospectively reviewed all paediatric patients who sought Japanese Kampo therapy at our outpatient clinics between April 1, 2012, and April 30, 2013; we selected patients who were diagnosed with paediatric EBD and were treated with YKS. Results. After screening all candidates, 3 patients were eligible for this analysis. Their average age was 11.6 years (range 10–13 years). All 3 patients responded very well to YKS within 1 month. No drug-related adverse events were observed during the course of YKS treatment. Conclusion. Yokukansan may be efficacious for paediatric EBD. We believe these results warrant further evaluation of the clinical efficacy and safety of Yokukansan for paediatric EBD in a carefully designed, double-blind, randomized clinical study. PMID:24204394

  10. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  11. Electronic Equipment Cold Plates

    DTIC Science & Technology

    1976-04-01

    using fans or blowers to force the air through the cooling device». ^J^lJ^^i 5!°^ it ia ’«"^"o^ve. nonto«ic. nonfla—able, *nd possesses good ...Techniques GENERAL THERMAL CONTROL SYSTEMS AND THEIR REgUIREMENTS FLON DISTRIBUTION IN MANIFOLDS THE COLD PLATE IA ,! 1 3 S 12 15 33 32 32... IA .1 132 132 132 155 169 179 183 r (1) Air-Cooled Cold Plate No. (2) Air-Cooled Cold Plate No. (3) Air-cooled Cold Plate No. (4) Air-Cooled

  12. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  13. How the interior viscosity structure of a terrestrial planet controls plate driving forces and plate tectonics

    NASA Astrophysics Data System (ADS)

    Hoeink, T.; Lenardic, A.; Jellinek, M.; Richards, M. A.

    2011-12-01

    One of the fundamental unresolved problems in Earth and planetary science is the generation of plate tectonics from mantle convection. Important achievements can be made when considering rheological properties in the context of mantle convection dynamics. Among these milestones are (1) a deeper understanding of the balance of forces that drive and resist plate motion and (2) the dynamic generation of narrow plate boundaries (that lead to a piecewise continuous surface velocity distribution). Extending classic plate-tectonic theory we predict a plate driving force due to viscous coupling at the base of the plate from fast flow in the asthenosphere. Flow in the asthenosphere is due to shear-driven contributions from an overriding plate and due to additional pressure-driven contributions. We use scaling analysis to show that the extent to which this additional plate-driving force contributes to plate motions depends on the lateral dimension of plates and on the relative viscosities and thicknesses of lithosphere and asthenosphere. Whereas slab-pull forces always govern the motions of plates with a lateral extent greater than the mantle depth, asthenosphere-drive forces can be relatively more important for smaller (shorter wavelength) plates, large relative asthenosphere viscosities or large asthenosphere thicknesses. Published plate velocities, tomographic images and age-binned mean shear wave velocity anomaly data allow us to estimate the relative contributions of slab-pull and asthenosphere-drive forces driving the motions of the Atlantic and Pacific plates. At the global scale of terrestrial planets, we use 3D spherical shell simulations of mantle convection with temperature-, depth- and stress dependent rheology to demonstrate that a thin low-viscosity layer (asthenosphere) governs convective stresses imparted to the lithosphere. We find, consistent with theoretical predictions, that convective stresses increase for thinner asthenospheres. This result might

  14. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating

    PubMed Central

    Tsai, Stanley; Bliven, Emily K.; von Rechenberg, Brigitte; Kindt, Philipp; Augat, Peter; Henschel, Julia; Fitzpatrick, Daniel C.; Madey, Steven M.

    2017-01-01

    Objectives: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. Methods: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. Results: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. Conclusions: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing. PMID:27861456

  15. Buckling analysis for axially compressed flat plates, structural sections, and stiffened plates reinforced with laminated composites

    NASA Technical Reports Server (NTRS)

    Viswanathan, A. V.; Soong, T.; Miller, R. E., Jr.

    1971-01-01

    A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked plate and beam elements. Plates are idealized as multilayered orthotropic elements. Structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply-supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections, and stiffened plates is investigated. Buckling loads are the lowest of all possible general and local failure modes, and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections, and stiffened plates including boron-reinforced structures are discussed. In general correlations are reasonably good.

  16. BAO Plate Archive Project

    NASA Astrophysics Data System (ADS)

    Mickaelian, A. M.; Gigoyan, K. S.; Gyulzadyan, M. V.; Paronyan, G. M.; Abrahamyan, H. V.; Andreasyan, H. R.; Azatyan, N. M.; Kostandyan, G. R.; Samsonyan, A. L.; Mikayelyan, G. A.; Farmanyan, S. V.; Harutyunyan, V. L.

    2017-12-01

    We present the Byurakan Astrophysical Observatory (BAO) Plate Archive Project that is aimed at digitization, extraction and analysis of archival data and building an electronic database and interactive sky map. BAO Plate Archive consists of 37,500 photographic plates and films, obtained with 2.6m telescope, 1m and 0.5m Schmidt telescopes and other smaller ones during 1947-1991. The famous Markarian Survey (or the First Byurakan Survey, FBS) 2000 plates were digitized in 2002-2005 and the Digitized FBS (DFBS, www.aras.am/Dfbs/dfbs.html) was created. New science projects have been conducted based on this low-dispersion spectroscopic material. Several other smaller digitization projects have been carried out as well, such as part of Second Byurakan Survey (SBS) plates, photographic chain plates in Coma, where the blazar ON 231 is located and 2.6m film spectra of FBS Blue Stellar Objects. However, most of the plates and films are not digitized. In 2015, we have started a project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage. Armenian Virtual Observatory (ArVO, www.aras.am/Arvo/arvo.htm) database will accommodate all new data. The project runs in collaboration with the Armenian Institute of Informatics and Automation Problems (IIAP) and will continues during 4 years in 2015-2018. The final result will be an Electronic Database and online Interactive Sky map to be used for further research projects. ArVO will provide all standards and tools for efficient usage of the scientific output and its integration in international databases.

  17. Hypervelocity impact on shielded plates

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1993-01-01

    A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

  18. Modic changes in lumbar spine: prevalence and distribution patterns of end plate oedema and end plate sclerosis.

    PubMed

    Xu, Lei; Chu, Bin; Feng, Yang; Xu, Feng; Zou, Yue-Fen

    2016-01-01

    The purpose of this study is to evaluate the distribution of end plate oedema in different types of Modic change especially in mixed type and to analyze the presence of end plate sclerosis in various types of Modic change. 276 patients with low back pain were scanned with 1.5-T MRI. Three radiologists assessed the MR images by T1 weighted, T2 weighted and fat-saturation T2 weighted sequences and classified them according to the Modic changes. Pure oedematous end plate signal changes were classified as Modic Type I; pure fatty end plate changes were classified as Modic Type II; and pure sclerotic end plate changes as Modic Type III. A mixed feature of both Types I and II with predominant oedematous signal change is classified as Modic I-II, and a mixture of Types I and II with predominant fatty change is classified as Modic II-I. Thus, the mixed types can further be subdivided into seven subtypes: Types I-II, Types II-I, Types I-III, Types III-I, Types II-III, Types III-II and Types I-III. During the same period, 52 of 276 patients who underwent CT and MRI were retrospectively reviewed to determine end plate sclerosis. (1) End plate oedema: of the 2760 end plates (276 patients) examined, 302 end plates showed Modic changes, of which 82 end plates showed mixed Modic changes. The mixed Modic changes contain 92.7% of oedematous changes. The mixed types especially Types I-II and Types II-I made up the majority of end plate oedematous changes. (2) End plate sclerosis: 52 of 276 patients were examined by both MRI and CT. Of the 520 end plates, 93 end plates showed Modic changes, of which 34 end plates have shown sclerotic changes in CT images. 11.8% of 34 end plates have shown Modic Type I, 20.6% of 34 end plates have shown Modic Type II, 2.9% of 34 end plates have shown Modic Type III and 64.7% of 34 end plates have shown mixed Modic type. End plate oedema makes up the majority of mixed types especially Types I-II and Types II-I. The end plate sclerosis on CT images may

  19. 46 CFR 160.061-1 - Applicable specifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...—Iron and steel; sheet, tinned (tin plate). QQ-W-423—Wire, steel, corrosion-resisting HH-P-91—Packing, fiber, hard sheet. CCC-F-451—Flannel, canton. (2) Military specifications: MIL-H-2846—Hooks, fish, steel...

  20. 46 CFR 160.061-1 - Applicable specifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...—Iron and steel; sheet, tinned (tin plate). QQ-W-423—Wire, steel, corrosion-resisting HH-P-91—Packing, fiber, hard sheet. CCC-F-451—Flannel, canton. (2) Military specifications: MIL-H-2846—Hooks, fish, steel...

  1. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.

    PubMed

    Sohn, Hoon-Sang; Kim, Won Ju; Shon, Min Soo

    2015-08-01

    Current literatures describe good clinical outcomes of acute displaced fracture of clavicle treated with minimally invasive plate osteosynthesis (MIPO). But, there are little comparative data of the outcomes between open plating and MIPO techniques. We compared the outcomes of open plating and MIPO for treatment of acute displaced clavicular shaft fractures. The author performed a retrospective review on a consecutive series of patients with clavicular shaft fracture who underwent open plating or MIPO. Fourteen patients were treated with open plating with interfragmentary screw fixation, and 19 were treated with the MIPO technique without exposing a fracture site itself. A superior plating method was applied to both groups. Patient demographics, clinical outcomes using Constant score and University of California Los Angeles (UCLA) shoulder score, operation time, union rate, complications, and radiographic evaluation were evaluated. There were no statistically significant differences in the demographic data, including patient's variables (age, gender, involved side, smoking, alcohol, and diabetic status) and fracture characteristics (trauma mechanism, distribution of fracture type, presence of polytrauma, and time from trauma to surgery) between the two groups. Mean operation time was 87.5 min in open plating and 77.2 min in MIPO (p=0.129). The mean time to union was 15.7 weeks in patients who underwent open plating and 16.8 weeks in patients who underwent MIPO (p=0.427). Although there was no significant difference, nonunion developed 1 case in MIPO while none was in open plating. Four patients in open plating had skin numbness (none in MIPO, p=0.024). There was no significant difference in the Constant score and UCLA score of the two surgical methods. This study showed that both open plating with interfragmentary screw fixation (Open plating) and minimally invasive plate osteosynthesis (MIPO) are equally effective and safe treatment methods for acute displaced

  2. Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates

    PubMed Central

    Ganesh, VK; Ramakrishna, K; Ghista, Dhanjoo N

    2005-01-01

    Background In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress-shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress-shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress-shielding of the layer of the bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. Method In order to address this problem, we propose to use stiffness-graded plates. Accordingly, we have computed (by finite-element analysis) the stress distribution in the fractured bone fixed by composite plates, whose stiffness is graded both longitudinally and transversely. Results It can be seen that the stiffness-graded composite-plates cause less stress-shielding (as an example: at 50% of the healing stage, stress at the fracture interface is compressive in nature i.e. 0.002 GPa for stainless steel plate whereas stiffness graded plates provides tensile stress of 0.002 GPa. This means that stiffness graded plate is allowing the 50% healed bone to participate in loadings). Stiffness-graded plates are more flexible, and hence permit more bending of the fractured bone. This results in higher compressive stresses induced at the fractured faces accelerate bone-healing. On the other hand, away from the fracture interface the reduced stiffness and elastic modulus of the plate causes the neutral axis of the composite structure to be lowered into the bone resulting in the higher tensile stress in the bone-layer underneath the plate, wherein is conducive to the bone preserving its tensile strength. Conclusion Stiffness graded plates (with in-built variable stiffness) are deemed to offer less stress-shielding to the bone, providing higher compressive stress at the fractured interface (to induce accelerated healing) as well as higher tensile

  3. Catch and release: How do kinetochores hook the right microtubules during mitosis?

    PubMed Central

    Sarangapani, Krishna K.; Asbury, Charles L.

    2014-01-01

    Sport fishermen keep tension on their lines to prevent hooked fish from releasing. A molecular version of this angler’s trick, operating at kinetochores, ensures accuracy during mitosis: The mitotic spindle attaches randomly to chromosomes and then correctly bioriented attachments are stabilized due to the tension exerted on them by opposing microtubules. Incorrect attachments, which lack tension, are unstable and release quickly, allowing another chance for biorientation. Stabilization of molecular interactions by tension also occurs in other physiological contexts such as cell adhesion, motility, hemostasis, and tissue morphogenesis. Here we review models for the stabilization of kinetochore attachments with an eye toward emerging models for other force-activated systems. While attention in the mitosis field has focused mainly on one kinase-based mechanism, multiple mechanisms may act together to stabilize properly bioriented kinetochores and some principles governing other tension-sensitive systems may apply to kinetochores as well. PMID:24631209

  4. Surgical treatment of isolated zygomatic fracture: Outcome comparison between titanium plate and bioabsorbable plate.

    PubMed

    Wu, Chao-Ming; Chen, Ying-An; Liao, Han-Tsung; Chen, Chih-Hao; Pan, Chun-Hao; Chen, Chien-Tzung

    2017-05-10

    Zygoma fracture is of clinical importance because malar prominence plays an essential role in facial appearance. Traditionally, most maxillofacial surgeons perform osteosynthesis with titanium plates and screws for rigid fixation. However, this procedure has certain disadvantages that include the possibility of implant exposure, palpability or loosening of the screws, painful irritation, temperature sensitization, and radiographic artifacts. In this study, we compared the function and satisfaction outcome between Bonamates ® bioabsorbable implant and Leibinger titanium implant. Consecutively 53 patients with isolated unilateral zygomatic fracture that were treated with the Bonamates ® bioabsorbable plate system, n = 53 were compared to patients with the titanium plate system, n = 55 in the period between 2009 and 2013. All patients were followed-up at least 6 months. Preoperative and postoperative facial computed tomography (CT) scans were performed and scored from 0 to 2 in the 5 areas of zygoma. A score of 2 indicated the most severely displaced fracture in one of the areas. A visual analogue scale ranging from 0 to 10 was used to assess the postoperative aesthetic and functional satisfactions. The mean ages of the patients in the bioabsorbable and titanium plate groups were 33 years and 30 years, respectively. The male to female ratios were 1.2:1 (bioabsorbable plate group) and 1.1:1 (titanium plate group). The average preoperative CT scan scores of the bioabsorbable and titanium plate groups were 5.7 and 5.1, respectively. The postoperative CT scan scores of the bioabsorbable and titanium plate groups were 1.3 and 1.1, respectively. The implant cost of the bioabsorbable group was approximately 6-fold higher than that of the titanium plate group. The complication rate was similar in both groups and included complications such as palpable implant, skin irritation, and hypersensitive cheek. The patients in both groups attained similar mouth-opening function

  5. Scanning nozzle plating system. [for etching or plating metals on substrates without masking

    NASA Technical Reports Server (NTRS)

    Oliver, G. D. (Inventor)

    1974-01-01

    A plating system is described in which a substrate to be plated is supported on a stationary platform. A nozzle assembly with a small nozzle is supplied with a plating solution under high pressure, so that a constant-flow stream of solution is directed to the substrate. The nozzle assembly is moved relative to the substrate at a selected rate and movement pattern. A potential difference (voltage) is provided between the substrate and the solution in the assembly. The voltage amplitude is modulated so that only when the amplitude is above a minimum known value plating takes place.

  6. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  7. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  8. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  9. The generalized mean zone plate

    NASA Astrophysics Data System (ADS)

    Xia, Tian; Cheng, Shubo; Tao, Shaohua

    2018-06-01

    In this paper a generalized mean zone plate is proposed, which generates twin foci located at the positions satisfying the expression of the generalized mean, which includes the m-golden mean, precious mean, and so on. The generalized mean zone plate can be designed to generate twin foci with various position ratios. The diffraction properties of the generalized mean zone plates have been investigated with simulations and experiments. The results show that the ratio of the positions of the twin foci for the generalized mean zone plate can be designed with the selected zone plate parameters.

  10. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  11. Laser-driven flyer plate

    DOEpatents

    Paisley, Dennis L.

    1991-01-01

    Apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma.

  12. Comparison of Thermal Performances between Low Porosity Perforate Plate and Flat Plate Solar Air Collector

    NASA Astrophysics Data System (ADS)

    Chan, Hoy-Yen; Vinson, A. A.; Baljit, S. S. S.; Ruslan, M. H.

    2018-04-01

    Flat plate solar air collector is the most common collector design, which is relatively simpler to fabricate and lower cost. In the present study, perforated plate solar collector was developed to improve the system thermal performance. A glazed perforated plate of 6mm holes diameter with square geometry was designed and installed as the absorber of the collector. The influences of solar radiation intensity and mass flow rate on the thermal performance were investigated. The perforated collector was compared with the flat plate solar collector under the same operating conditions. The highest values of thermal efficiency in this study for the perforated plate (PP) and the flat plate (FP) solar collectors were 59% and 36% respectively, at solar radiation intensity of 846 Wm-2 and mass flow rate of 0.02 kgs-1. Furthermore, PP collector gave better thermal performance compared to FP collector; and compared to previous studies, the present perforated design was compatible with the flat plate with double pass designs.

  13. Data set on the characterization of the phytoestrogenic extract and isolated compounds of the roots of Inula racemosa Hook F (Asteraceae).

    PubMed

    Kalachaveedu, Mangathayaru; Raghavan, Divya; Telapolu, Srivani; Kuruvilla, Sarah; Kedike, Balakrishna

    2018-04-01

    The data presented in this article are related to the research article entitled ' Phyto estrogenic effect of Inula racemosa Hook. f - A cardio protective root drug in traditional medicine, (Mangathayaru K, Divya R, Srivani T et al., 2018) [1]. It describes the characterization details of the root extract and the compounds isolated from them that were shown to be phytoestrogenic in vivo and in vitro respectively.

  14. "Hook-like effect" causes false-negative point-of-care urine pregnancy testing in emergency patients.

    PubMed

    Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F

    2013-01-01

    Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. An AT-hook protein DEPRESSED PALEA1 physically interacts with the TCP Family transcription factor RETARDED PALEA1 in rice.

    PubMed

    Yin, Dedong; Liu, Xue; Shi, Zhenying; Li, Dayong; Zhu, Lihuang

    2018-01-01

    The cereal crops (such as rice and maize) which belong to the grass family, are the most important grain crops for human beings, and the development of their flower and inflorescence architecture has attracted extensive attention. Although multiple genes involved in the regulation of floral and inflorescence organogenesis have been identified, the underlying molecular mechanisms are largely unknown. Previously, we identified rice depressed palea1 (dp1) mutants with defects in main structure of palea and its enhancer RETARDED PALEA1 (REP1). DP1 is an AT-hook protein while REP1 is a TCP transcription factor, both of which are important regulators of palea development. However, the relationship of these two proteins has not been elucidated yet. Here, we demonstrated that DP1 interacts physically with REP1 both in yeast and in rice protoplasts. Considering the close phylogenetic relationship between maize and rice, we further hypothesize that their orthologs in maize, BARREN STALK FASTIGIATE (BAF1) and BRANCH ANGLE DEFECTIVE 1 (BAD1), may interact physically. Subsequently, we verified their physical interaction, indicating that the interaction between AT-hook proteins and TCP proteins is conserved in rice and maize. Our findings may reveal a novel molecular mechanism of floral and inflorescence development in grasses. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  17. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  18. View northeast, wharf A, portion AA, details showing earlier piers ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View northeast, wharf A, portion AA, details showing earlier piers and braces sloping toward water, reused charred plates for existing decking - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  19. Negative βhCG and Molar Pregnancy: The Hook Effect.

    PubMed

    Lobo Antunes, Isabel; Curado, Joana; Quintas, Ana; Pereira, Alcides

    2017-09-29

    Molar pregnancy, included in gestational trophoblastic disease, is a benign pathology with ability to metastasize, usually occurring with excessively high βhCG levels. Clinical scenario is usually a woman in extremes of reproductive age presenting with amenorrhoea, pain and vaginal blood loss; signs derived from high βhCG levels may be present (hyperthyroidism, hyperemesis). Diagnosis is based on a positive pregnancy test - usually a qualitative urinary test. The limitation of this test results from its inability to become positive in presence of markedly high levels of βhCG, saturating the antigens used - known as the 'hook effect'. With the widespread use of gynaecological ultrasound cases of molar pregnancy have been diagnosed in timely fashion. We describe a case referred as a degenerating fibroid, with a negative urinary pregnancy test. Transvaginal ultrasound was highly suggestive of molar pregnancy, which was confirmed with a quantitative βhCG test, allowing for timely treatment. The importance of a high index of suspicion for this pathology is tremendous to avoid the devastating consequences of a delayed diagnosis.

  20. Quantum Hooke's Law to Classify Pulse Laser Induced Ultrafast Melting

    NASA Astrophysics Data System (ADS)

    Hu, Hao; Ding, Hepeng; Liu, Feng

    2014-03-01

    We investigate the ultrafast crystal-to-amorphous phase transition induced by femtosecond pulse laser excitation by exploiting the property of quantum electronic stress (QES) induced by the electron-hole plasma, which follows quantum Hooke's law. We demonstrates that two types of crystal-to-amorphous transitions occur in two distinct material classes: the faster nonthermal process, having a time scale shorter than one picosecond (ps), must occur in materials like ice having an anomalous phase diagram characterized with dTm/dP <0, where Tm is the melting temperature and P is pressure; while the slower thermal process, having a time scale of several ps, occurs preferably in other materials. The nonthermal process is driven by the QES acting like a negative internal pressure, which is generated predominantly by the holes in the electron-hole plasma that increases linearly with hole density. These findings significantly advance our fundamental understanding of physics underlying the ultrafast crystal-to-amorphous phase transitions, enabling quantitative a priori prediction. The work was supported by DOE-BES (Grant # DE-FG02-04ER46148), NSF MRSEC (Grant No. DMR-1121252) and DOE EFRC (Grant Number DE-SC0001061).