Sample records for ulno-carpal abutment syndrome

  1. Carpal Tunnel Syndrome

    MedlinePlus

    ... a passing cramp? It could be carpal tunnel syndrome. The carpal tunnel is a narrow passageway of ... three times more likely to have carpal tunnel syndrome than men. Early diagnosis and treatment are important ...

  2. Carpal Tunnel Syndrome

    PubMed Central

    Zimmerman, Gregory R.

    1994-01-01

    Carpal tunnel syndrome is a neuropathy resulting from compression of the median nerve as it passes through a narrow tunnel in the wrist on its way to the hand. The lack of precise objective and clinical tests, along with symptoms that are synonymous with other syndromes in the upper extremity, cause carpal tunnel syndrome to appear to be a rare entity in athletics. However, it should not be ruled out as a possible etiology of upper extremity paralysis in the athlete. More typically, carpal tunnel syndrome is the most common peripheral entrapment neuropathy encountered in industry. Treatment may include rest and/or splinting of the involved wrist, ice application, galvanic stimulation, or iontophoresis to reduce inflammation, and then transition to heat modalities and therapeutic exercises for developing flexibility, strength, and endurance. In addition, an ergonomic assessment should be conducted, resulting in modifications to accommodate the carpal tunnel syndrome patient. ImagesFig 3.Fig 4.Fig 5.Fig 6.Fig 7. PMID:16558255

  3. Influence of the thickness of the transverse carpal ligament in carpal tunnel syndrome.

    PubMed

    Bartolomé-Villar, A; Pastor-Valero, T; Fuentes-Sanz, A; Varillas-Delgado, D; García-de Lucas, F

    To determine if the thickness of the transverse carpal ligament measured by T2 axial magnetic resonance imaging actually influences the onset of carpal tunnel syndrome. 94 patients between January 2015 and June 2016, of whom 28 had carpal tunnel syndrome, underwent magnetic resonance imaging, 37 with discomfort in different carpus regions without symptoms of carpal tunnel and 29 healthy subjects. Two observers performed 3 measurements in 3 different levels, and in the 3 groups of patients. No statistically significant differences in transverse carpal ligament thickness measurements between the carpal tunnel syndrome group and the group without carpal tunnel involvement became apparent, but statistical differences between the control group and the carpal tunnel syndrome group, and between the control group and the group without involvement of the carpal tunnel were observed. In both these groups, the thickness of the transverse ligament was higher than in the control group. An increase in the thickness of the transverse ligament in was found in this study in subjects with involvement of carpal tunnel syndrome as evidenced by numerous studies in the literature. There is no certain causative factor, but rather a set of facts that make onset of the syndrome possible in a specific group of patients. Carpal tunnel syndrome is multifactorial. The thickness of the transverse ligament does not directly affect the onset of symptoms. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Carpal Tunnel Syndrome (For Kids)

    MedlinePlus

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Search English Español Carpal Tunnel Syndrome KidsHealth / For Kids / Carpal Tunnel Syndrome What's in this article? Where ...

  5. Management of Carpal Tunnel Syndrome.

    PubMed

    Mooar, Pekka A; Doherty, William J; Murray, Jayson N; Pezold, Ryan; Sevarino, Kaitlyn S

    2018-03-15

    The American Academy of Orthopaedic Surgeons (AAOS) has developed Appropriate Use Criteria (AUC) for Management of Carpal Tunnel Syndrome. Evidence-based information, in conjunction with the clinical expertise of physicians, was used to develop the criteria to improve patient care and obtain best outcomes while considering the subtleties and distinctions necessary in making clinical decisions. To provide the evidence foundation for this AUC, the AAOS Evidence-Based Medicine Unit provided the writing panel and voting panel with the 2016 AAOS Clinical Practice Guideline titled Management of Carpal Tunnel Syndrome Evidence-Based Clinical Practice Guideline. The Management of Carpal Tunnel Syndrome AUC clinical patient scenarios were derived from indications typical of patients with suspected carpal tunnel syndrome in clinical practice, as well as from current evidence-based clinical practice guidelines and supporting literature to identify the appropriateness of treatments. The 135 patient scenarios and 6 treatments were developed by the writing panel, a group of clinicians who are specialists in this AUC topic. Next, a separate, multidisciplinary, voting panel (made up of specialists and nonspecialists) rated the appropriateness of treatment of each patient scenario using a 9-point scale to designate a treatment as Appropriate (median rating, 7 to 9), May Be Appropriate (median rating, 4 to 6), or Rarely Appropriate (median rating, 1 to 3).

  6. Carpal Tunnel Syndrome: Physical Therapy or Surgery?

    PubMed

    2017-03-01

    Carpal tunnel syndrome causes pain, numbness, and weakness in the wrist and hand. Nearly 50% of all work-related injuries are linked to carpal tunnel syndrome, and people with this injury are more likely to miss work because of it. Patients with carpal tunnel syndrome can be treated with physical therapy or surgery. Although surgery may be considered when the symptoms are severe, more than a third of patients do not return to work within 8 weeks after an operation. Based on the potential side effects and risks of surgery, patients often ask if they might try physical therapy first. An article in the March 2017 issue of JOSPT assesses the effectiveness of therapy and surgery to treat carpal tunnel syndrome. J Orthop Sports Phys Ther 2017;47(3):162. doi:10.2519/jospt.2017.0503.

  7. Carpal tunnel syndrome - an occupational hazard facing dentistry.

    PubMed

    Abichandani, Sagar; Shaikh, Saquib; Nadiger, Ramesh

    2013-10-01

    The authors wished to evaluate the comprehensive literature on carpal tunnel syndrome to discover work specific to carpal tunnel syndrome among dentists in order to determine whether there is any correlation with dentists having a higher prevalence of its occurrence. A review of dental literature involving carpal tunnel syndrome was undertaken. Details appearing in the literature before 1995 was reviewed in a comprehensive manner and the literature after 1995 were reviewed electronically. The prevalence of carpal tunnel syndrome is higher in dental professionals involved in various aspects of dental specialties. Abnormal postures, including muscle imbalances, muscle necrosis, trigger points, hypomobile joints, nerve compression and spinal disk herniation or degeneration may result in serious detrimental physiological changes in the body. These changes often result in pain, injury or possible neuroskeletal disorders. Dentists have an increased risk of carpal tunnel syndrome and precautions and care should be exercised to prevent detrimental irreversible changes occurring. © 2013 FDI World Dental Federation.

  8. Stonefish envenomation with acute carpal tunnel syndrome.

    PubMed

    Ling, Samuel K K; Cheng, S C; Yen, C H

    2009-12-01

    Stonefish envenomation is a common marine sting. Although stonefish injuries are commonly sustained during maritime activities, this local delicacy can also be considered a regional occupational hazard for chefs. The availability and consumption of stonefish in local restaurants has increased the risk of acute carpal tunnel syndrome after a stonefish injury. This case report describes acute carpal tunnel syndrome following stonefish envenomation. An excellent recovery was achieved after surgical decompression of the carpal tunnel syndrome. Standard management of stonefish injuries should therefore take into account the possibility that this orthopaedic emergency may complicate the injury.

  9. [Occupational carpal tunnel syndrome: 27 cases].

    PubMed

    Slimane, Neila Ben; Elleuch, Mohamed; Gharbi, Ezzedine; Babay, Habib; Hamdoun, Moncef

    2010-09-01

    Carpal tunnel syndrome is the most frequent of tunnel syndromes in the field of the professional sphere. It is related to repetitive movements of flexion-extension of the wrist and fingers or to a support on the heel of the hands. To determine the posts in a risk and to specify the modalities of guaranteed reimbursement of professional carpal tunnel syndrome. A retrospective and descriptive study of 27 medical files of employees indemnified for professional carpal tunnel syndrome registered in the medical control services of the social security office in charge of medical insurance of Tunis and Sousse during a period of 10 years (1995-2004). There were 24 women and 3 men with the average age of 40 years all occupying posts in a risk. Their average time of service is 15 years. Tow-thirds of them work in the clothing and textile industry. The attack is bilateral in 13 cases. Nightly acroparaesthesia rules the clinical rate (44.44% of cases). Motor disorders are noted in the quarter of cases. The electromyogram had confirmed diagnosis in all of cases. The previous state study put in evidence the antecedent of carpal tunnel syndrome in 5 cases and diabetes in one case. Twenty-one patients had profit of permanent partial incapacity with a rate varying from 3 to 25%. Five had got a transfer of working place and one stayed in the same post with a half-time work. The professional origin of carpal tunnel syndrome must be called up in front of an activity in a risk. The reparation is done according to picture 82 of occupational diseases.

  10. Sonographic diagnosis of carpal tunnel syndrome: a study in 200 hospital workers*

    PubMed Central

    Castro, Adham do Amaral e; Skare, Thelma Larocca; Nassif, Paulo Afonso Nunes; Sakuma, Alexandre Kaue; Barros, Wagner Haese

    2015-01-01

    Objective To describe the prevalence of carpal tunnel syndrome in a sample of 200 healthy hospital workers, establishing the respective epidemiological associations. Materials and Methods Two hundred individuals were submitted to wrist ultrasonography to measure the median nerve area. They were questioned and examined for epidemiological data, body mass index, carpal tunnel syndrome signs and symptoms, and submitted to the Boston carpal tunnel questionnaire (BCTQ) to evaluate the carpal tunnel syndrome severity. A median nerve area ≥ 9 mm2 was considered to be diagnostic of carpal tunnel syndrome. Results Carpal tunnel syndrome was diagnosed by ultrasonography in 34% of the sample. It was observed the association of carpal tunnel syndrome with age (p < 0.0001), paresthesia (p < 0.0001), Tinel’s test (p < 0.0001), Phalen’s test (p < 0.0001), BCTQ score (p < 0.0001), and years of formal education (p < 0.0001). Years of formal education was the only variable identified as an independent risk factor for carpal tunnel syndrome (95% CI = 1.03 to 1.24). Conclusion The prevalence of carpal tunnel syndrome in a population of hospital workers was of 34%. The number of years of formal education was the only independent risk factor for carpal tunnel syndrome. PMID:26543279

  11. [Case-control study on transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after distal radius fracture].

    PubMed

    Wang, Yan-jie; Wang, Shi-gang; Miao, Shu-juan; Su, Xia

    2011-06-01

    To investigate the effects of open reduction by palm side for the distal radius fracture and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after operation. From March 2000 to March 2007, 32 patients (8 males and 24 females, ranging in age from 46 to 66 years) with distal radius fracture were treated with open reduction by palm side and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection; while 30 patients (7 males and 23 females,ranging in age from 45 to 65 years) only with open reduction by palm side and T shape plate internal fixation. The incidences of delayed carpal tunnel syndrome between the two groups were compared. Among 32 patients treated with open reduction by palm side and T shape plate internal fixation with anterior transverse carpal ligament resection, 3 patients had delayed carpal tunnel syndrome; while in 30 patients treated with open reduction by palm side and T shape plate internal fixation, 10 patients had delayed carpal tunnel syndrome. There was significant statistically difference (P < 0.05%). Simultaneous anterior transverse carpal ligament resection can effectively prevent the delayed carpal tunnel syndrome occurrence for the distal radius fracture with open reduction by palm side.

  12. Sonographically guided percutaneous needle release of the carpal tunnel for treatment of carpal tunnel syndrome: preliminary report.

    PubMed

    McShane, John M; Slaff, Samantha; Gold, Judith E; Nazarian, Levon N

    2012-09-01

    The purpose of this study was to evaluate the effectiveness of a novel treatment procedure, sonographically guided percutaneous needle release of the carpal tunnel, for individuals with carpal tunnel syndrome. Seventeen patients (89% female; mean age, 62 years; SD, 13.6 years) with a clinical diagnosis of carpal tunnel syndrome who had undergone a sonographically guided percutaneous needle release of the carpal tunnel at least 6 months before follow-up evaluation were retrospectively reviewed. At the follow-up evaluation, to ascertain previous and current symptoms as well as functional impairment, the patients filled out a hand diagram and a questionnaire. In addition, medical records were reviewed, and patients were queried regarding complications such as infection or nerve damage. Median nerve sonographic measurements and a physical evaluation were performed on a subset of 13 patients who came to the office for evaluation. Postprocedure sonography showed that patients had a significantly smaller (P = .03) cross-sectional area of the median nerve compared to pretreatment values. In addition, patients had significantly fewer symptoms (P < .0001), less functional impairment (P = .0002), and an improved hand diagram score (P < .0001). Postprocedure patients had grip strength that was 12 lb below average (≈1 SD below) compared to grip strength norms. However, most patients (84.6%) had negative clinical diagnostic test results for carpal tunnel syndrome, and 86% said they were satisfied with the procedure. There were no procedure-related infections or nerve injuries. Of the patients with carpal tunnel syndrome who agreed to participate in this study, most had favorable symptomatic and functional outcomes. Sonographically guided percutaneous needle release of the carpal tunnel may be an alternative option to traditional surgical treatment of carpal tunnel syndrome.

  13. Nonsurgically treated carpal tunnel syndrome in the manual worker.

    PubMed

    Monsivais, J J; Bucher, P A; Monsivais, D B

    1994-10-01

    This study evaluates the course of carpal tunnel syndrome in a group of manual laborers who declined surgery for personal or social reasons. Thirty-five patients and 67 extremities with carpal tunnel syndrome were evaluated in a group of manual laborers. The carpal tunnel syndrome was classified as mild, moderate, or severe on the basis of initial evaluation data. Sensory batteries, motor and sensory conduction velocities, and electrical studies were performed on a scheduled basis. Follow-up ranged between 14 and 58 months, with an average of 34.3 months. Three patients became worse and one improved during the study period. All others remained unchanged. Six patients returned to work, but only three returned to their original jobs. Although carpal tunnel syndrome does not appear to be a progressive condition once the triggering cause is removed, nonsurgical treatment does not seem to be the treatment of choice for patients who must continue in a manual labor position.

  14. Posture and Loading in the Pathomechanics of Carpal Tunnel Syndrome: A Review.

    PubMed

    Vignais, Nicolas; Weresch, Justin; Keir, Peter J

    2016-01-01

    Carpal tunnel syndrome is a neuropathy of the median nerve at the wrist, and represents the most common peripheral neuropathy. It has long been an issue in the workplace because of healthcare costs and loss of productivity. The two main pathomechanisms of carpal tunnel syndrome include increased hydrostatic pressure within the carpal tunnel (carpal tunnel pressure) and contact stress (or impingement). As most cases of carpal tunnel syndrome in the workplace are labelled "idiopathic", a clear understanding of the physical parameters that may act as pathomechanisms is critical for its prevention. The aim of this review is to examine and quantify the influence of posture and loading factors on the increase of carpal tunnel pressure and median nerve contact stress. Forearm, wrist, and finger postures, as well as fingertip force have significant effects on carpal tunnel pressure. Contact stress on the median nerve is mainly a product of wrist posture and musculotendinous loading. Anatomical and musculoskeletal sources have been proposed to explain these effects. This critical review provides an improved understanding of pathomechanisms and etiology underlying carpal tunnel syndrome.

  15. [Carpal tunnel syndrome treatment].

    PubMed

    De Angelis, Rossella; Salaffi, Fausto; Filippucci, Emilio; Grassi, Walter

    2006-01-01

    Carpal tunnel syndrome, the most common peripheral neuropathy, results from compression of the median nerve at the wrist, and is a cause of pain, numbness and tingling in the upper extremities and an increasingly recognized cause of work disability. If carpal tunnel syndrome seems likely, conservative management with splinting should be initiated. Moreover, it has suggested that patients reduce activities at home and work that exacerbate symptoms. Pyridoxine and diuretics, since are largely utilised, are no more effective than placebo in relieving the symptoms. Non steroidal anti-inflammatory drugs and orally administered corticosteroids can be effective for short-term management (two to four weeks), but local corticosteroid injection may improve symptoms for a longer period. Injection is especially effective if there is no loss of sensibility or thenar-muscle atrophy and weakness, and if symptoms are intermittent rather than constant. If symptoms are refractory to conservative measures, the option of surgical therapy may be considered.

  16. Atraumatic acute carpal tunnel syndrome in a patient taking dabigatran.

    PubMed

    Sibley, Paul A; Mandel, Richard J

    2012-08-01

    Acute carpal tunnel syndrome is an uncommon diagnosis most often related to blunt trauma requiring immediate surgical decompression to avoid serious sequelae. Patients who present with bleeding-related acute carpal tunnel syndrome tend to have severe pain, rapid onset of swelling, and neurologic symptoms that appear early and progress rapidly secondary to mass effect. Acute carpal tunnel syndrome can occur in anticoagulated patients spontaneously or after minor trauma. This article describes a case of a 57-year-old man with progressive pain and paresthesias in the median nerve distribution after reaching for a picture frame. He was taking dabigatran, a direct thrombin inhibitor, for atrial fibrillation. He developed acute carpal tunnel syndrome secondary to spontaneous bleeding into the carpal canal and flexor tenosynovium with hematoma formation requiring surgical decompression. He reported immediate pain relief postoperatively, had no further bleeding complications, and regained full median nerve function within 2 months.Dabigatran has gained recent popularity for the treatment of atrial fibrillation. Unlike warfarin, its use does not involve regular laboratory monitoring or dose titration. The risks and benefits of dabigatran should be considered carefully by the prescriber, particularly in patients taking medications that may alter its metabolism. Aspirin and nonsteroidal anti-inflammatory drugs may have effects similar to dabigatran and may increase the risk of bleeding problems. Should acute carpal tunnel syndrome occur, the authors recommend prompt surgical decompression rather than conservative management. The modification of anticoagulant therapy should be considered on a case-by-case basis. Copyright 2012, SLACK Incorporated.

  17. Corticosteroid injection for the treatment of carpal tunnel syndrome

    PubMed Central

    O'Gradaigh, D; Merry, P

    2000-01-01

    OBJECTIVE—To compare low and high dose, and short and long acting corticosteroids in the treatment of carpal tunnel syndrome.
METHODS—A randomised, controlled, single blind trial with electromyographic and subjective outcome measures.
RESULTS—25 mg hydrocortisone is as effective as higher doses or long acting triamcinolone at a six week and six month follow up.
CONCLUSION—As low dose steroid is as effective, and potentially less toxic, this should be the recommended dose for injection of carpal tunnel syndrome.

 PMID:11053073

  18. Nonoccupational Risk Factors for Carpal Tunnel Syndrome

    PubMed Central

    Solomon, Daniel H; Katz, Jeffrey N; Bohn, Rhonda; Mogun, Helen; Avorn, Jerry

    1999-01-01

    OBJECTIVE To examine the relation between selected nonoccupational risk factors and surgery for carpal tunnel syndrome. DESIGN Case-control study using an administrative database. PARTICIPANTS Enrollees of New Jersey Medicare or Medicaid programs during 1989 to 1991. MEASUREMENTS The outcome of interest was open or endoscopic carpal tunnel release. We examined the relation between carpal tunnel release and diabetes mellitus, thyroid disease, inflammatory arthritis, hemodialysis, pregnancy, use of corticosteroids, and hormone replacement therapy. MAIN RESULTS In multivariate models, inflammatory arthritis was strongly associated with carpal tunnel release (odds ratio [OR] 2.9; 95% confidence interval [CI] 2.2, 3.8). However, corticosteroid use also appeared to be associated with a greater likelihood of undergoing carpal tunnel release, even in the absence of inflammatory arthritis (OR 1.6; 95% CI 1.2, 2.1). Diabetes had a weak but significant association with carpal tunnel release (OR 1.4; 95% CI 1.2, 1.8), as did hypothyroidism (OR 1.7; 95% CI 1.1, 2.8), although patients with hyperthyroidism did not have any change in risk. Women who underwent carpal tunnel release were almost twice as likely to be users of estrogen replacement therapy as controls (OR 1.8; 95% CI 1.0, 3.2). CONCLUSIONS Although inflammatory arthritis is the most important nonoccupational risk factor for carpal tunnel release, these data substantiate the increase in risk associated with diabetes and untreated hypothyroidism. Further investigation in detailed clinical studies will be necessary to confirm whether changes in corticosteroid use and hormone replacement therapy offer additional means of risk reduction for this common condition. PMID:10337041

  19. Single injection of platelet-rich plasma as a novel treatment of carpal tunnel syndrome.

    PubMed

    Malahias, Michael Alexander; Johnson, Elizabeth O; Babis, George C; Nikolaou, Vasileios S

    2015-11-01

    Both in vitro and in vivo experiments have confirmed that platelet-rich plasma has therapeutic effects on many neuropathies, but its effects on carpal tunnel syndrome remain poorly understood. We aimed to investigate whether single injection of platelet-rich plasma can improve the clinical symptoms of carpal tunnel syndrome. Fourteen patients presenting with median nerve injury who had suffered from mild carpal tunnel syndrome for over 3 months were included in this study. Under ultrasound guidance, 1-2 mL of platelet-rich plasma was injected into the region around the median nerve at the proximal edge of the carpal tunnel. At 1 month after single injection of platelet-rich plasma, Visual Analogue Scale results showed that pain almost disappeared in eight patients and it was obviously alleviated in three patients. Simultaneously, the disabilities of the arm, shoulder and hand questionnaire showed that upper limb function was obviously improved. In addition, no ultrasonographic manifestation of the carpal tunnel syndrome was found in five patients during ultrasonographic measurement of the width of the median nerve. During 3-month follow-up, the pain was not greatly alleviated in three patients. These findings show very encouraging mid-term outcomes regarding use of platelet-rich plasma for the treatment of carpal tunnel syndrome.

  20. Bilateral widespread mechanical pain sensitivity in carpal tunnel syndrome: evidence of central processing in unilateral neuropathy.

    PubMed

    Fernández-de-las-Peñas, César; de la Llave-Rincón, Ana Isabel; Fernández-Carnero, Josué; Cuadrado, María Luz; Arendt-Nielsen, Lars; Pareja, Juan A

    2009-06-01

    The aim of this study was to investigate whether bilateral widespread pressure hypersensitivity exists in patients with unilateral carpal tunnel syndrome. A total of 20 females with carpal tunnel syndrome (aged 22-60 years), and 20 healthy matched females (aged 21-60 years old) were recruited. Pressure pain thresholds were assessed bilaterally over median, ulnar, and radial nerve trunks, the C5-C6 zygapophyseal joint, the carpal tunnel and the tibialis anterior muscle in a blinded design. The results showed that pressure pain threshold levels were significantly decreased bilaterally over the median, ulnar, and radial nerve trunks, the carpal tunnel, the C5-C6 zygapophyseal joint, and the tibialis anterior muscle in patients with unilateral carpal tunnel syndrome as compared to healthy controls (all, P < 0.001). Pressure pain threshold was negatively correlated to both hand pain intensity and duration of symptoms (all, P < 0.001). Our findings revealed bilateral widespread pressure hypersensitivity in subjects with carpal tunnel syndrome, which suggest that widespread central sensitization is involved in patients with unilateral carpal tunnel syndrome. The generalized decrease in pressure pain thresholds associated with pain intensity and duration of symptoms supports a role of the peripheral drive to initiate and maintain central sensitization. Nevertheless, both central and peripheral sensitization mechanisms are probably involved at the same time in carpal tunnel syndrome.

  1. Carpal Tunnel Syndrome Associated with Oral Bisphosphonates. A Population-Based Cohort Study

    PubMed Central

    Carvajal, Alfonso; Martín Arias, Luis H.; Sáinz, María; Escudero, Antonio; Fierro, Inmaculada; Sauzet, Odile; Cornelius, Victoria R.; Molokhia, Mariam

    2016-01-01

    Background Bisphosphonates are widely used to prevent osteoporotic fractures. Some severe musculoskeletal reactions have been described with this medication; among them, some cases of carpal tunnel syndrome. Thus, the aim of this study was to explore whether bisphosphonates may be associated with this syndrome. Methods A cohort study was conducted to compare exposed to unexposed women; the exposed group was that composed of women having received at least one prescription of an oral bisphosphonate. For the purpose, we used information from The Health Improvement Network (THIN) database. The outcome of interest was defined as those women diagnosed with carpal tunnel syndrome. A survival analysis was performed; the Cox proportional hazard model was used to calculate hazard ratios and 95% confidence intervals, and to adjust for identified confounding variables. Results Out of a sample of 59,475 women older than 51 years, 19,825 were treated with bisphosphonates during the period studied. No differences in age distribution or mean follow-up time were observed between the two groups in comparison. Overall, there were 572 women diagnosed with carpal tunnel syndrome, 242 (1.2%) in the group exposed to bisphosphonates, and 330 (0.8%) in the unexposed. An adjusted hazard ratio of developing carpal tunnel syndrome of 1.38 (95%CI, 1.15–1.64) was found for women exposed to bisphosphonates; no significant changes in the hazard ratios were found when considering different levels of bisphosphonate exposure. Conclusions An increased risk of carpal tunnel syndrome is associated with the use of bisphosphonates in postmenopausal women. PMID:26765346

  2. Functional deficits in carpal tunnel syndrome reflect reorganization of primary somatosensory cortex

    PubMed Central

    Kettner, Norman; Holden, Jameson; Lee, Jeungchan; Kim, Jieun; Cina, Stephen; Malatesta, Cristina; Gerber, Jessica; McManus, Claire; Im, Jaehyun; Libby, Alexandra; Mezzacappa, Pia; Morse, Leslie R.; Park, Kyungmo; Audette, Joseph; Tommerdahl, Mark; Napadow, Vitaly

    2014-01-01

    Carpal tunnel syndrome, a median nerve entrapment neuropathy, is characterized by sensorimotor deficits. Recent reports have shown that this syndrome is also characterized by functional and structural neuroplasticity in the primary somatosensory cortex of the brain. However, the linkage between this neuroplasticity and the functional deficits in carpal tunnel syndrome is unknown. Sixty-three subjects with carpal tunnel syndrome aged 20–60 years and 28 age- and sex-matched healthy control subjects were evaluated with event-related functional magnetic resonance imaging at 3 T while vibrotactile stimulation was delivered to median nerve innervated (second and third) and ulnar nerve innervated (fifth) digits. For each subject, the interdigit cortical separation distance for each digit’s contralateral primary somatosensory cortex representation was assessed. We also evaluated fine motor skill performance using a previously validated psychomotor performance test (maximum voluntary contraction and visuomotor pinch/release testing) and tactile discrimination capacity using a four-finger forced choice response test. These biobehavioural and clinical metrics were evaluated and correlated with the second/third interdigit cortical separation distance. Compared with healthy control subjects, subjects with carpal tunnel syndrome demonstrated reduced second/third interdigit cortical separation distance (P < 0.05) in contralateral primary somatosensory cortex, corroborating our previous preliminary multi-modal neuroimaging findings. For psychomotor performance testing, subjects with carpal tunnel syndrome demonstrated reduced maximum voluntary contraction pinch strength (P < 0.01) and a reduced number of pinch/release cycles per second (P < 0.05). Additionally, for four-finger forced-choice testing, subjects with carpal tunnel syndrome demonstrated greater response time (P < 0.05), and reduced sensory discrimination accuracy (P < 0.001) for median nerve, but not ulnar nerve

  3. Effects of taping therapy for carpal space expansion on electrophysiological change in patients with carpal tunnel syndrome.

    PubMed

    Park, Yeong-Dong; Park, Yun-Jin; Park, Sang-Seo; Lee, Hae-Lim; Moon, Hyeong-Hun; Kim, Myung-Ki

    2017-06-01

    Taping therapy is one of the most conservative treatments for carpal tunnel syndrome (CTS). Preceding research studied on pain control, grip strength, and wrist function but no studies have been reported on electrophysiolgical changes after taping therapy. The aim of this study is to evaluate the effects of taping therapy for carpal space expansion on electrophysiological in 20 female patients aged from 40s to 60s with CTS. Experimental group applied taping therapy for carpal space expansion twice a week for 4 weeks and control group did not. There were significant differences between distal motor latency (DML) and sensory nerve conduction velocity (SNCV), but no difference between compound muscle action potential and sensory nerve action potential (SNAP) after 4 weeks taping treatment. Also, there was a significant difference in DML, SNCV, and SNAP in between groups. In conclusion, taping therapy for carpal space expansion can help to reduce the pressure of the carpal tunnel in CTS patients with mild symptoms.

  4. Carpal Tunnel Syndrome in Aberrant Muscle Syndrome: A Case Report and Review of the Literature.

    PubMed

    Steele, Jessica; Coombs, Christopher

    2018-06-01

    Aberrant Muscle Syndrome (AMS) is a rare congenital hand difference that is characterised by unilateral non-progressive muscular hyperplasia. The aetiology of aberrant muscle syndrome is not known, but a recently published case has shown a somatic PIK3CA activating mutation in a patient with AMS. Carpal tunnel syndrome (CTS) in children is rare. The most common causes are the mucopolysaccaridoses but space-occupying lesions have also been reported to cause CTS in children. We report the first case of CTS in a child with AMS successfully treated with open carpal tunnel release and excision of aberrant muscles.

  5. Employees' Knowledge of Carpal Tunnel Syndrome.

    ERIC Educational Resources Information Center

    Gandy-Goldston, Terrie M.

    A study examined employees' knowledge of the causes of carpal tunnel syndrome (CTS), its prevention, and their legal rights after being diagnosed with CTS. A 24-item questionnaire was administered to a random sample of 30 Chicago-area employees who had been afflicted with CTS. Of those surveyed, 99% considered their CTS injury related to their…

  6. Is carpal tunnel syndrome an occupational disease? A review.

    PubMed

    Zyluk, Andrzej

    2013-05-27

    In many countries, including Poland, carpal tunnel syndrome is considered to be a disease of possible occupational etiology. This review presents information about work-related risk-factors which comprise the use of handheld vibrating machinery, forceful gripping of objects with hands, repetitive and frequent manual tasks and forced postures of the wrist (flexion/extension). However, the character of the job is only one of possible several factors leading to the development of the disease, as its etiology is multifactorial. Conditions to be taken into consideration when recognizing a case as occupational carpal tunnel syndrome were shown to include: coexistence of predisposing diseases (diabetes), constitutional factors (obesity), character, level and duration of the exposure to harmful stimuli during the workday as well as total duration of work upon exposure. Consideration of these circumstances provides adequate ground for recognizing a particular case as occupational. Nonetheless, even accepting the disease as occupational should be temporary, as surgical carpal tunnel release is an effective method of treatment and should allow the patient to return to previously performed work.

  7. Carpal tunnel syndrome in women working in tea agriculture

    PubMed Central

    Devrimsel, Gul; Kirbas, Serkan; Yildirim, Murat; Turkyilmaz, Aysegul Kucukali; Sahin, Nilay

    2014-01-01

    OBJECTIVE: The aim of this cross-sectional study was to determine the frequency of carpal tunnel syndrome (CTS) among women using tea leaf scissors and compare it with normal population. METHODS: Two hundred hands of 100 women using tea leaf scissors (tea leaf scissors group) and 112 hands of 56 healthy women (control group) were clinically and electrophysiologically evaluated for CTS. Women using tea leaf scissors were evaluated with visual analog scale (VAS) for pain and Boston Carpal Tunnel Syndrome Questionnaire for symptoms and functional status. RESULTS: Carpal tunnel syndrome was diagnosed bilaterally in 62 (62%) and unilaterally in 7 (7%) women using tea leaf scissors, whereas 2 (3.57%) bilateral and 6 (10.71%) unilateral cases of CTS was diagnosed in controls. The differences in demographic factors were not statistically significant. In women with CTS using tea leaf scissors, mean symptom severity, functional status, and VAS scores were 2.73±0.60, 2.42±0.71 and 5.19±1.84, respectively. There was statistically significant difference in the frequency of CTS between women using tea leaf scissors and the control group and the risk of having CTS among women using tea leaf scissors was approximately 12 times greater (p<0.001). CONCLUSION: In tea agriculture, working with repetitive flexions and extensions of the wrist highly increases the risk of developing CTS. PMID:28058318

  8. Diagnosis of motor fascicle compression in carpal tunnel syndrome.

    PubMed

    Modi, C S; Ho, K; Hegde, V; Boer, R; Turner, S M

    2010-06-01

    Median nerve motor fascicle compression in patients with carpal tunnel syndrome is usually characterised by reduced finger grip and pinch strength, loss of thumb abduction and opposition strength and thenar atrophy. The functional outcome in patients with advanced changes may be poor due to irreversible intraneural changes. The aim of this study was to investigate patient-reported symptoms, which may enable a clinical diagnosis of median nerve motor fascicle compression to be made irrespective of the presence of advanced signs. One hundred and twelve patients (166 hands) with a clinical diagnosis of carpal tunnel syndrome were referred to the neurophysiology department and completed symptom severity questionnaires with subsequent neurophysiological testing. An increasing frequency of pain experienced by patients was significantly associated with an increased severity of median nerve motor fascicle compression with prolonged motor latencies measured in patients that described pain as a predominant symptom. An increasing frequency of paraesthesia and numbness and weakness associated with dropping objects was significantly associated with both motor and sensory involvement but not able to distinguish between them. This study suggests that patients presenting with a clinical diagnosis of carpal tunnel syndrome with pain as a frequently experienced and predominant symptom require consideration for urgent investigation and surgical treatment to prevent chronic motor fascicle compression with permanent functional deficits. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  9. Comparison of the efficacy of lidocaine and betamethasone dipropionate in carpal tunnel syndrome injection.

    PubMed

    Dernek, Bahar; Aydin, Tugba; Koseoglu, Pinar Kursuz; Kesiktas, Fatma Nur; Yesilyurt, Tugba; Diracoglu, Demirhan; Aksoy, Cihan

    2017-01-01

    Carpal tunnel syndrome (CTS) is a commonly seen peripheral nerve mononeuropathy. Corticosteroid injection within the carpal tunnel is among the conservative treatment options. The exact mechanism of action of steroids is not fully clear; decreased inflammation surrounding nerves or tendons is thought to be the main effect. Lidocaine has been shown to have anti-inflammatory effects on certain cells (monocytes, macrophages, neutrophils etc.). The aim of this study is to evaulate the efficacy of lidocaine treatment as a alternative to corticosteroid treatment in carpal tunnel syndrome. A total of 67 carpal tunnel syndrome patients who were diagnosed with physical examination and EMG were evaluated. Twenty-nine patients received a mixture of normal saline solution and lidocaine (0.5 cc of normal saline solution and 0.5 cc of lidocaine) while 38 patients were administered betamethasone dipropionate (1 cc). Quick DASH (Disabilities of the Arm, Shoulder and Hand) and Visual Analog Scale (VAS) scores were noted in 1st, 3rd and 6th month follow-ups. There were no significant difference between saline solution + Lidocaine group and betamethasone dipropionate groups; initial, 1st, 3rd and 6th month VAS scores and QDASH scores (p > 0.05). Considering the potential side effects of corticosteroid, lidocaine injection is a good alternative treatment of carpal tunnel syndrome instead of corticosteroids.

  10. Low-power laser therapy for carpal tunnel syndrome: effective optical power

    PubMed Central

    Chen, Yan; Zhao, Cheng-qiang; Ye, Gang; Liu, Can-dong; Xu, Wen-dong

    2016-01-01

    Low-power laser therapy has been used for the non-surgical treatment of mild to moderate carpal tunnel syndrome, although its efficacy has been a long-standing controversy. The laser parameters in low-power laser therapy are closely related to the laser effect on human tissue. To evaluate the efficacy of low-power laser therapy, laser parameters should be accurately measured and controlled, which has been ignored in previous clinical trials. Here, we report the measurement of the effective optical power of low-power laser therapy for carpal tunnel syndrome. By monitoring the backside reflection and scattering laser power from human skin at the wrist, the effective laser power can be inferred. Using clinical measurements from 30 cases, we found that the effective laser power differed significantly among cases, with the measured laser reflection coefficient ranging from 1.8% to 54%. The reflection coefficient for 36.7% of these 30 cases was in the range of 10–20%, but for 16.7% of cases, it was higher than 40%. Consequently, monitoring the effective optical power during laser irradiation is necessary for the laser therapy of carpal tunnel syndrome. PMID:27630706

  11. Diagnostic utility of sonography and correlation between sonographic and clinical findings in patients with carpal tunnel syndrome.

    PubMed

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Kaneko, Tetsuya; Takagishi, Kenji

    2013-11-01

    First, we investigated the accuracy of carpal tunnel syndrome diagnosis by comparing the cross-sectional area of the median nerve measured at the level of proximal inlet of the carpal tunnel with that measured at the level of the distal radioulnar joint on sonography. Second, we evaluated the correlation between sonographic and neurophysiologic findings and clinical findings assessed by the Carpal Tunnel Syndrome Instrument of the Japanese Society for Surgery of the Hand (JSSH). Fifty wrists in 34 patients and 81 wrists in 45 healthy volunteers were examined. The proximal cross-sectional area and the difference (Δ) between the proximal and distal cross-sectional areas were calculated for each wrist. Nerve conduction velocity tests were performed for all patients with carpal tunnel syndrome. The proximal, distal, and Δ cross-sectional areas were compared for the two groups. We examined the correlation between the proximal, distal, and Δ areas, nerve conduction velocity findings, and JSSH scores in the patients. The diagnosis of carpal tunnel syndrome determined by the Δ cross-sectional area was more accurate than the diagnosis determined by the proximal area on receiver operating characteristic curve analysis (P = .006). Statistically significant correlations were found between proximal area, Δ area, and nerve conduction velocity findings (proximal, r = 0.45; P = .0013; Δ, r = 0.44; P = .001). The proximal and distal areas were positively correlated with the JSSH symptom severity score (proximal, r= 0.39; P= .005; distal, r = 0.35; P = .014). The cross-sectional area method using sonography has excellent performance for diagnosing carpal tunnel syndrome. It was useful for measuring the proximal and distal cross-sectional areas to evaluated the symptom severity and for calculating the Δ cross-sectional area to assess motor nerve damage in patients with carpal tunnel syndrome.

  12. [Clinical auxiliary diagnosis value of high frequency ultrasonographic measurements of the thickness of transverse carpal ligaments in carpal tunnel syndrome patients].

    PubMed

    Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R

    2016-04-18

    To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.

  13. What does the transverse carpal ligament contribute to carpal stability?

    PubMed

    Vanhees, Matthias; Verstreken, Frederik; van Riet, Roger

    2015-02-01

    Background The transverse carpal ligament is well known for its involvement in carpal tunnel syndrome, and sectioning of this ligament remains the definite treatment for this pathology. Some authors believe that the transverse carpal ligament is an important stabilizer of the carpal arch, whereas others do not consider it to be significant. Several studies have been performed, both in vivo and in in vitro. Sectioning of the transverse carpal ligament does not seem to have any effect on the width of the carpal arch in the unloaded condition. However, patients will load the arch during their activities of daily living. Materials and Methods A cadaveric study was done with distraction of the carpal bones before and after sectioning the transverse carpal ligament. Results With the transverse carpal ligament intact, the carpal arch is mobile, with distraction leading up to 50% widening of the arch. Sectioning of the transverse carpal ligament resulted in a significant widening of the carpal arch by a further 30%. Conclusions Loading of the carpal arch after sectioning of the transeverse carapal ligament leads to a significant increase in intracarpal mobility. This will inevitably influence carpal kinematics in the patient and might be responsible for some complications after simple carpal tunnel releases, such as pillar pain, palmar tenderness, and loss of grip strength.

  14. Pathological changes in the subsynovial connective tissue increase with self-reported carpal tunnel syndrome symptoms.

    PubMed

    Tat, Jimmy; Wilson, Katherine E; Keir, Peter J

    2015-05-01

    Fibrosis and thickening of the subysnovial connective tissue are the most common pathological findings in carpal tunnel syndrome. The relationship between subsynovial connective tissue characteristics and self-reported carpal tunnel syndrome symptoms was assessed. Symptoms were characterized using the Boston Carpal Tunnel Questionnaire and Katz hand diagram in twenty-two participants (11 with symptoms, 11 with no symptoms). Using ultrasound, the thickness of the subsynovial connective tissue was measured using a thickness ratio (subsynovial thickness/tendon thickness) and gliding function was assessed using a shear strain index ((Displacement(tendon)-Displacement(subsynovial))/Displacement(tendon)x 100). For gliding function, participants performed 10 repeated flexion-extension cycles of the middle finger at a rate of one cycle per second. Participants with symptoms had a 38.5% greater thickness ratio and 39.2% greater shear strain index compared to participants without symptoms (p<0.05). Ultrasound detected differences the SSCT in symptomatic group that was characterized by low self-reported symptom severity scores. This study found ultrasound useful for measuring structural and functional changes in the SSCT that could provide insight in the early pathophysiology associated with carpal tunnel syndrome symptoms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Coexisting cervical spondylotic myelopathy and bilateral carpal tunnel syndromes.

    PubMed

    Epstein, N E; Epstein, J A; Carras, R

    1989-03-01

    In six patients, operations for bilateral carpal tunnel syndromes (CTS) were performed or were about to be performed without the awareness of the presence of underlying cervical spondylo-stenosis. Only later, when symptoms of myeloradiculopathy were recognized, was the diagnosis confirmed and decompressive laminectomy performed. Because the symptoms of CTS may resemble or be masked and accentuated by the cervical disorder, patients with the presumed diagnosis of bilateral CTS should undergo appropriate critical neurologic, electrodiagnostic, and neuroradiologic (magnetic resonance imaging, computed tomography, myelo-computed tomography) assessment. If these guidelines are followed, the radiculopathy caused by cervical pathology will be appropriately recognized and treated, possibly averting the need for carpal tunnel decompression or modifying treatment.

  16. [Etiological factors of carpal tunnel syndrome in subjects occupationally exposed to monotype wrist movements].

    PubMed

    Lewańska, Magdalena; Walusiak-Skorupa, Jolanta

    2014-01-01

    Carpal tunnel syndrome (CTS) is the most common neuropathy of upper limbs and a leading cause of upper extremity musculoskeletal disorders, in terms of work exposure, repetitive and forceful exertions of the hand and use of vibrating hand tools. The aim of the study was to evaluate etiological factors of carpal tunnel syndrome in subjects occupationally exposed to monotype movements in wrist. We conducted the retrospective analysis of 300 patients (261 women, 39 men), mean age 52 years (standard deviation: +/-6.93) hospitalized with the suspicion of occupational CTS. The study revealed high percentage (68.7%) of diseases and systemic factors involved in the pathogenesis of CTS in the analyzed population, especially obesity (32%), thyroid diseases (28.7%), hormone replacement therapy and/or oophorectomy (16.3%) and diabetes mellitus (12%). In 111 patients the coexistence of at least a couple of potential etiological factors of the neuropathy was recognized. Clinical analysis and occupational exposure allowed to diagnose occupational carpal tunnel syndrome in 18 (6%) patients only. The undeniable long-term (20(.2+/-9.3 years) occupational exposure to repetitive, forceful movements in the wrist was observed in this group. The results of our study indicated that non-occupational etiological factors of CTS predominated and in 37% of patients at least several factors were found. The analysis showed the high prevalence of CTS in workers employed in various sectors of industry, including so called "blue collar" workers. Our study confirmed the multifactorial etiology of carpal tunnel syndrome, however, occupational agents contributed to only 6% of cases.

  17. Consumer health information on the Internet about carpal tunnel syndrome: indicators of accuracy.

    PubMed

    Frické, Martin; Fallis, Don; Jones, Marci; Luszko, Gianna M

    2005-02-01

    To identify indicators of accuracy for consumer health information on the Internet. Several popular search engines were used to find websites on carpal tunnel syndrome. The accuracy and completeness of these sites were determined by orthopedic surgeons. It also was noted whether proposed indicators of accuracy were present. The correlation between proposed indicators of accuracy and the actual accuracy of the sites was calculated. A total of 116 websites and 29 candidate indicators were examined. A high Google toolbar rating of the main page of a site, many inlinks to the main page of a site, and an unbiased presentation of information on carpal tunnel syndrome were considered genuine indicators of accuracy. Many proposed indicators taken from published guidelines did not indicate accuracy (e.g., the author or sponsor having medical credentials). There are genuine indicators of the accuracy of health information on the Internet. Determining these indicators, and informing providers and consumers of health information about them, would be useful for public health care. Published guidelines have proposed many indicators that are obvious to unaided observation by the consumer. However, indicators that make use of the invisible link structure of the Internet are more reliable guides to accurate information on carpal tunnel syndrome.

  18. Carpal tunnel syndrome, the search for a cost-effective surgical intervention: a randomised controlled trial.

    PubMed Central

    Lorgelly, Paula K.; Dias, Joseph J.; Bradley, Mary J.; Burke, Frank D.

    2005-01-01

    OBJECTIVE: There is insufficient evidence regarding the clinical and cost-effectiveness of surgical interventions for carpal tunnel syndrome. This study evaluates the cost, effectiveness and cost-effectiveness of minimally invasive surgery compared with conventional open surgery. PATIENTS AND METHODS: 194 sufferers (208 hands) of carpal tunnel syndrome were randomly assigned to each treatment option. A self-administered questionnaire assessed the severity of patients' symptoms and functional status pre- and postoperatively. Treatment costs were estimated from resource use and hospital financial data. RESULTS: Minimally invasive carpal tunnel decompression is marginally more effective than open surgery in terms of functional status, but not significantly so. Little improvement in symptom severity was recorded for either intervention. Minimally invasive surgery was found to be significantly more costly than open surgery. The incremental cost effectiveness ratio for functional status was estimated to be 197 UK pounds, such that a one percentage point improvement in functioning costs 197 UK pounds when using the minimally invasive technique. CONCLUSIONS: Minimally invasive carpal tunnel decompression appears to be more effective but more costly. Initial analysis suggests that the additional expense for such a small improvement in function and no improvement in symptoms would not be regarded as value-for-money, such that minimally invasive carpal tunnel release is unlikely to be considered a cost-effective alternative to the traditional open surgery procedure. PMID:15720906

  19. Effect of custom-made and prefabricated orthoses on grip strength in persons with carpal tunnel syndrome.

    PubMed

    Mlakar, Maja; Ramstrand, Nerrolyn; Burger, Helena; Vidmar, Gaj

    2014-06-01

    Based on the literature, patients with carpal tunnel syndrome are suggested to wear a custom-made wrist orthosis immobilizing the wrist in a neutral position. Many prefabricated orthoses are available on the market, but the majority of those do not assure neutral wrist position. We hypothesized that the use of orthosis affects grip strength in persons with carpal tunnel syndrome in a way that supports preference for custom-made orthoses with neutral wrist position over prefabricated orthoses. Experimental. Comparisons of grip strength for three types of grips (cylindrical, lateral, and pinch) were made across orthosis types (custom-made, prefabricated with wrist in 20° of flexion, and none) on the affected side immediately after fitting, as well as between affected side without orthosis and nonaffected side. Orthosis type did not significantly affect grip strength (p = 0.661). Cylindrical grip was by far the strongest, followed by lateral and pinch grips (p < 0.050). The grips of the affected side were weaker than those of the nonaffected side (p = 0.002). In persons with carpal tunnel syndrome, neither prefabricated orthoses with 20° wrist extension nor custom-made wrist orthoses with neutral wrist position influenced grip strength of the affected hand. Compared to the nonaffected side, the grips of the affected side were weaker. The findings from this study can be used to guide application of orthoses to patients with carpal tunnel syndrome. © The International Society for Prosthetics and Orthotics 2013.

  20. Effect of Wrist Posture on Carpal Tunnel Pressure while Typing

    PubMed Central

    Rempel, David M.; Keir, Peter J.; Bach, Joel M.

    2009-01-01

    Long weekly hours of keyboard use may lead to or aggravate carpal tunnel syndrome. The effects of typing on fluid pressure in the carpal tunnel, a possible mediator of carpal tunnel syndrome, are unknown. Twenty healthy subjects participated in a laboratory study to investigate the effects of typing at different wrist postures on carpal tunnel pressure of the right hand. Changes in wrist flexion/extension angle (p = 0.01) and radial/ulnar deviation angle (p = 0.03) independently altered carpal tunnel pressure; wrist deviations in extension or radial deviation were associated with an increase in pressure. The activity of typing independently elevated carpal tunnel pressure (p= 0.001) relative to the static hand held in the same posture. This information can guide the design and use of keyboards and workstations in order to minimize carpal tunnel pressure while typing. The findings may also be useful to clinicians and ergonomists in the management of patients with carpal tunnel syndrome who use a keyboard. PMID:18383144

  1. Randomized controlled trial of local progesterone vs corticosteroid injection for carpal tunnel syndrome.

    PubMed

    Raeissadat, S A; Shahraeeni, S; Sedighipour, L; Vahdatpour, B

    2017-10-01

    A number of studies have demonstrated the neuroprotective effects of progesterone and its influence on the recovery after neural injury. Few studies investigated the efficacy of local progesterone in carpal tunnel syndrome. The objective of this study was to compare the long-term effects of progesterone vs corticosteroid local injections in patients with mild and moderate carpal tunnel syndrome. In this randomized clinical trial, 78 patients with carpal tunnel syndrome were assigned to two groups. Patients were treated with a single local injection of triamcinolone acetonide in one group and single local injection of hydroxy progesterone in the other group. Variables including pain (based on visual analogue scale), symptom severity, and functional status (based on Bostone/Levine symptom severity and functional status scale) and nerve conduction study were evaluated before and 6 months after the treatments. All outcome measures including pain and electrophysiologic findings, improved in both groups and there were no meaningful differences between two groups regarding mentioned variables except for functional outcome, which was significantly better in progesterone compared with corticosteroid group at 6-month follow-up (P=.04). The efficacy of progesterone local injection in mild and moderate CTS is equal and somehow superior to corticosteroid injection for relieving symptoms and improving functional and electrophysiologic findings at long-term follow-up. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. The Incidence of Complex Regional Pain Syndrome in Simultaneous Surgical Treatment of Carpal Tunnel Syndrome and Dupuytren Contracture.

    PubMed

    Buller, Mitchell; Schulz, Steven; Kasdan, Morton; Wilhelmi, Bradon J

    2017-07-01

    To determine the incidence of complex regional pain syndrome (CRPS) in the concurrent surgical treatment of Dupuytren contracture (DC) and carpal tunnel syndrome (CTS) through a thorough review of evidence available in the literature. The indices of 260 hand surgery books and PubMed were searched for concomitant references to DC and CTS. Studies were eligible for inclusion if they evaluated the outcome of patients treated with simultaneous fasciectomy or fasciotomy for DC and carpal tunnel release using CRPS as a complication of treatment. Of the literature reviewed, only 4 studies met the defined criteria for use in the study. Data from the 4 studies were pooled, and the incidence of recurrence and complications, specifically CRPS, was noted. The rate of CRPS was found to be 10.4% in the simultaneous treatment group versus 4.1% in the fasciectomy-only group. This rate is nearly half the 8.3% rate of CRPS found in a randomized trial of patients undergoing carpal tunnel release. Our analysis demonstrates a marginal increase in the occurrence of CRPS by adding the carpal tunnel release to patients in need of fasciectomy, contradicting the original reports demonstrating a much higher rate of CRPS. This indicates that no clear clinical risk is associated with simultaneous surgical treatment of DC and CTS. In some patients, simultaneous surgical management of DC and CTS can be accomplished safely with minimal increased risk of CRPS type 1.

  3. Treatment of carpal tunnel syndrome with polarized polychromatic noncoherent light (Bioptron light): a preliminary, prospective, open clinical trial.

    PubMed

    Stasinopoulos, D; Stasinopoulos, I; Johnson, M I

    2005-04-01

    Our aim was to assess the efficacy of polarized polychromatic noncoherent light (Bioptron light) in the treatment of idiopathic carpal tunnel syndrome. Carpal tunnel syndrome is the most common compression neuropathy, but no satisfactory conservative treatment is available at present. An uncontrolled experimental study was conducted in patients who visited our clinic from mid-2001 to mid-2002. A total of 25 patients (22 women and three men) with unilateral idiopathic carpal tunnel syndrome, mild to moderate nocturnal pain, and paraesthesia lasting >3 months participated in the study. The average age of the patients was 47.4 years and the average duration of patients' symptoms was 5.2 months. Polarized polychromatic noncoherent light (Bioptron light) was administered perpendicular to the carpal tunnel area. The irradiation time for each session was 6 min at an operating distance of 5-10 cm from the carpal tunnel area, three times weekly for 4 weeks. Outcome measures used were the participants' global assessments of nocturnal pain and paraesthesia, respectively, at 4 weeks and 6 months. At 4 weeks, two patients (8%) had no change in nocturnal pain, six (24%) were in slightly less nocturnal pain, 12 (48%) were much better in regard to nocturnal pain and five (20%) were pain-free. At 6 months, three patients (12%) were slightly better in regard to nocturnal pain, 13 (52%) were much better regarding nocturnal pain, and nine patients (36%) were pain-free. At 4 weeks, four patients (16%) had no change in paraesthesia, five (20%) were slightly better, 13 patients (52%) were much better, and three patients (12%) were without paraesthesia. At 6 months, two patients (8%) had no change in paraesthesia, two (8%) were slightly better, 14 (56%) were much better, and seven (28%) were without paraesthesia. Nocturnal pain and paraesthesia associated with idiopathic carpal tunnel syndrome improved during polarized polychromatic noncoherent light (Bioptron light) treatment. Controlled

  4. A persisting median artery in a patient with symbrachydactyly and carpal tunnel syndrome.

    PubMed

    Tollan, C J; Sivarajan, V

    2008-07-01

    A persisting median artery associated with carpal tunnel syndrome in a patient with symbrachydactyly has not been previously described in the literature. It is unclear whether there may be a developmental association between persistence of a median artery and Symbrachydactyly.

  5. Yoga Asanas for the Relief and Prevention of Carpal Tunnel Syndrome.

    ERIC Educational Resources Information Center

    Beleu, Steve

    This collection of yoga asanas (exercises) can help relieve the pain of carpal tunnel syndrome (CTS) and help prevent CTS among people who work on computer terminals. For maximum benefit, the exercises should be practiced daily or on as regular a schedule as possible. They are not intended to replace surgery or a physician's prescribed care. They…

  6. Ultrasound-Guided Carpal Tunnel Release Using Dynamic Expansion of the Transverse Safe Zone in a Patient With Postpolio Syndrome: A Case Report.

    PubMed

    Henning, Troy; Lueders, Daniel; Chang, Kate; Yang, Lynda

    2018-03-06

    The prevalence of carpal tunnel syndrome (CTS) in patients with postpolio syndrome occurs at a rate of 22%. Irrespective of those with CTS, 74% of postpolio patients weight bear through their arms for ambulation or transfers. As open carpal tunnel release is performed along the weight-bearing region of the wrist, their functional independence may be altered while recovering. This case demonstrates that ultrasound-guided carpal tunnel release was successfully performed in a patient with postpolio syndrome allowing him to immediately weight bear through his hands after the procedure so he could recover at home. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Carpal tunnel syndrome: just a peripheral neuropathy?

    PubMed

    Fernández-de-Las-Peñas, César; Plaza-Manzano, Gustavo

    2018-06-05

    Carpal tunnel syndrome (CTS) is considered just a peripheral neuropathy of the upper extremity associated to the compression of the median nerve. There is evidence suggesting the presence of complex sensitization mechanisms in CTS. These processes are manifested by symptoms in extra-median regions and the presence of bilateral sensory and motor impairments. These sensory and motor changes are not associated to electrodiagnostic findings. The presence of sensitization mechanisms suggests that CTS should not be considered just as a peripheral neuropathy. The presence of altered nociceptive gain processing should be considered for therapeutic management of CTS by considering the application of therapeutic interventions that modulate nociceptive barrage into the CNS.

  8. Abductor Digiti Minimi Flap for Vascularized Coverage in the Surgical Management of Complex Regional Pain Syndrome Following Carpal Tunnel Release.

    PubMed

    Cheung, Kevin; Klausmeyer, Melissa A; Jupiter, Jesse B

    2017-11-01

    The development of Complex Regional Pain Syndrome (CRPS) represents a potentially devastating complication following carpal tunnel release. In the presence of a suspected incomplete release of the transverse carpal ligament or direct injury to the median nerve, neurolysis as well as nerve coverage to prevent recurrent scar has been shown to be effective. Retrospective chart review and telephone interview was conducted for patients who underwent abductor digiti minimi flap coverage and neurolysis of the median nerve for CRPS following carpal tunnel release. Fourteen wrists in 12 patients were reviewed. Mean patient age was 64 years (range, 49-83 years), and the mean follow-up was 44 months. Carpal tunnel outcome instrument scores were 47.4 ± 6.8 preoperatively and 27.1 ± 10.6 at follow-up ( P < .001). Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) scores at follow-up were 29.4 ± 26. No significant postoperative complications were identified. The abductor digiti minimi flap is a reliable option with minimal donor site morbidity. It provides predictable coverage when treating CRPS following carpal tunnel syndrome.

  9. Rewiring the primary somatosensory cortex in carpal tunnel syndrome with acupuncture

    PubMed Central

    Maeda, Yumi; Kim, Hyungjun; Kettner, Norman; Kim, Jieun; Cina, Stephen; Malatesta, Cristina; Gerber, Jessica; McManus, Claire; Ong-Sutherland, Rebecca; Mezzacappa, Pia; Libby, Alexandra; Mawla, Ishtiaq; Morse, Leslie R.; Kaptchuk, Ted J.; Audette, Joseph

    2017-01-01

    Abstract Carpal tunnel syndrome is the most common entrapment neuropathy, affecting the median nerve at the wrist. Acupuncture is a minimally-invasive and conservative therapeutic option, and while rooted in a complex practice ritual, acupuncture overlaps significantly with many conventional peripherally-focused neuromodulatory therapies. However, the neurophysiological mechanisms by which acupuncture impacts accepted subjective/psychological and objective/physiological outcomes are not well understood. Eligible patients (n = 80, 65 female, age: 49.3 ± 8.6 years) were enrolled and randomized into three intervention arms: (i) verum electro-acupuncture ‘local’ to the more affected hand; (ii) verum electro-acupuncture at ‘distal’ body sites, near the ankle contralesional to the more affected hand; and (iii) local sham electro-acupuncture using non-penetrating placebo needles. Acupuncture therapy was provided for 16 sessions over 8 weeks. Boston Carpal Tunnel Syndrome Questionnaire assessed pain and paraesthesia symptoms at baseline, following therapy and at 3-month follow-up. Nerve conduction studies assessing median nerve sensory latency and brain imaging data were acquired at baseline and following therapy. Functional magnetic resonance imaging assessed somatotopy in the primary somatosensory cortex using vibrotactile stimulation over three digits (2, 3 and 5). While all three acupuncture interventions reduced symptom severity, verum (local and distal) acupuncture was superior to sham in producing improvements in neurophysiological outcomes, both local to the wrist (i.e. median sensory nerve conduction latency) and in the brain (i.e. digit 2/3 cortical separation distance). Moreover, greater improvement in second/third interdigit cortical separation distance following verum acupuncture predicted sustained improvements in symptom severity at 3-month follow-up. We further explored potential differential mechanisms of local versus distal acupuncture using

  10. A randomized, controlled trial of magnetic therapy for carpal tunnel syndrome.

    PubMed

    Baute, Vanessa; Keskinyan, Vahakn S; Sweeney, Erica R; Bowden, Kayla D; Gordon, Allison; Hutchens, Janet; Cartwright, Michael S

    2018-03-07

    Magnet therapy has been proposed as a treatment for neurologic conditions. In this this trial we assessed the feasibility and efficacy of a magnet inserted into a wristband for carpal tunnel syndrome (CTS). Twenty-two patients with mild to moderate CTS were randomized to wear a high-dose or low-dose "sham" magnetic wristband for 6 weeks. The primary outcome was the Symptom Severity Scale (SSS) of the Boston Carpal Tunnel Questionnaire. Secondary measures were nerve conduction studies (NCS), median nerve ultrasound, and compliance. Compliance for both groups was >90%. Improvements in the mean SSS, NCS, and median nerve ultrasound did not reach statistical significance. Magnet therapy via wristband is well-tolerated. Further investigations in larger populations are needed to determine efficacy. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.

  11. Endoscopic release for carpal tunnel syndrome.

    PubMed

    Vasiliadis, Haris S; Georgoulas, Petros; Shrier, Ian; Salanti, Georgia; Scholten, Rob J P M

    2014-01-31

    Carpal tunnel syndrome (CTS) is the most common compressive neuropathy of the upper extremity. It is caused by increased pressure on the median nerve between the transverse carpal ligament and the carpal bones. Surgical treatment consists of the release of the nerve by cutting the transverse carpal ligament. This can be done either with an open approach or endoscopically. To assess the effectiveness and safety of the endoscopic techniques of carpal tunnel release compared to any other surgical intervention for the treatment of CTS. More specifically, to evaluate the relative impact of endoscopic techniques in relieving symptoms, producing functional recovery (return to work and return to daily activities) and reducing complication rates. This review fully incorporates the results of searches conducted up to 5 November 2012, when we searched the Cochrane Neuromuscular Disease Group Specialized Register, CENTRAL, MEDLINE and EMBASE. There were no language restrictions. We reviewed the reference lists of relevant articles and contacted trial authors. We also searched trial registers for ongoing trials. We performed a preliminary screen of searches to November 2013 to identify any additional recent publications. We included any randomised controlled trials (RCTs) and quasi-RCTs comparing endoscopic carpal tunnel release (ECTR) with any other surgical intervention for the treatment of CTS. We used standard methodological procedures expected by the Cochrane Collaboration. Twenty-eight studies (2586 hands) were included. Twenty-three studies compared ECTR to standard open carpal tunnel release (OCTR), five studies compared ECTR with OCTR using a modified incision, and two studies used a three-arm design to compare ECTR, standard OCTR and modified OCTR.At short-term follow-up (three months or less), only one study provided data for overall improvement. We found no differences on the Symptom Severity Scale (SSS) (scale zero to five) (five studies, standardised mean

  12. [Case report: acute carpal tunnel syndrome with prolapse of the median nerve].

    PubMed

    Kindler, C; Lukas, B

    2013-10-01

    We report a case of an 80-year-old woman with an acute carpal tunnel syndrome. This was based on an acute episode of chondrocalcinoses and accompagnied by a prolaps of the median nerve into a gap of the forearm fascia as result of a cut injury in childhood. © Georg Thieme Verlag KG Stuttgart · New York.

  13. A pilot randomized double-blind placebo-controlled trial on topical chamomile (Matricaria chamomilla L.) oil for severe carpal tunnel syndrome.

    PubMed

    Hashempur, Mohammad Hashem; Lari, Zeinab Nasiri; Ghoreishi, Parissa Sadat; Daneshfard, Babak; Ghasemi, Mohammad Sadegh; Homayouni, Kaynoosh; Zargaran, Arman

    2015-11-01

    To assess the effectiveness of standardized topical Chamomile (Matricaria chamomilla L.) oil in patients with severe carpal tunnel syndrome, as a complementary treatment. A pilot randomized double-blind placebo-controlled trial was conducted. Twenty six patients with documented severe carpal tunnel syndrome were treated in two parallel groups with a night splint plus topical chamomile oil or placebo. They were instructed to use their prescribed oil for 4 weeks, twice daily. Symptomatic and functional status of the patients and their electrodiagnostic parameters were evaluated when enrolled and after the trial period, as our outcome measures. A significant improvement of symptomatic and functional status of patients in the chamomile oil group was observed (p = 0.019 and 0.016, respectively) compared with those in the placebo group. However, electrodiagnostic parameters showed no significant changes between the two groups. Chamomile oil improved symptomatic and functional status of patients with severe carpal tunnel syndrome. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. [Socio professional impact of surgical release of carpal tunnel syndrome].

    PubMed

    Kraiem, Aouatef Mahfoudh; Hnia, Hajer; Bouzgarrou, Lamia; Henchi, Mohamed Adnène; Khalfallah, Taoufik

    2016-01-01

    The objective was studying the socio-professional impact of release surgery for carpal tunnel syndrom (CTS). We conducted a cross-sectional study of patients operated for work-related CTS; data were collected in the Occupational Health Department at the University Hospital Tahar Sfar in Mahdia, Tunisia over a period of 8 years, from 1 January 2006 to December 2013. Data collection was performed using a survey form focusing on participants' socio-professional and medical characteristics and on their professional future. We used Karasek's questionnaire to study psychosocial constraints at work. The duration of a work stoppage following release surgery for CTS was significantly related to the existence of musculoskeletal disorders other than CTS, to a statement that the carpal tunnel syndrome was work related and to job seniority. As regards the professional future of operated employees, 50.7% remained in the same position, 15.3% were given customized workstation and 33.8% were offered a different position within the same company. The professional future of these employees was related to their occupational qualifications and to the type of sensory and/or motor impairment of median nerve detected during EMG test. A number of nonlesional factors determines the duration of the work stoppage, while the professional future of patients operated for CTS essentially depends on their professional qualifications and on EMG data. Certainly much broader studies would allow to refine these results.

  15. Carpal Tunnel Exercises: Can They Relieve Symptoms?

    MedlinePlus

    ... relieve symptoms, such as pain and numbness. These exercises are most effective when combined with other treatments, such as behavior changes or wrist splints, for mild to moderate carpal tunnel syndrome. If your symptoms ... exercises — one type of carpal tunnel exercise — might help ...

  16. Carpal tunnel syndrome: the role of occupational factors.

    PubMed

    Palmer, Keith T

    2011-02-01

    Carpal tunnel syndrome (CTS) is a fairly common condition in working-aged people, sometimes caused by physical occupational activities, such as repeated and forceful movements of the hand and wrist or use of hand-held, powered, vibratory tools. Symptoms may be prevented or alleviated by primary control measures at work, and some cases of disease are compensable. Following a general description of the disorder, its epidemiology and some of the difficulties surrounding diagnosis, this review focusses on the role of occupational factors in causation of CTS and factors that can mitigate risk. Areas of uncertainty, debate and research interest are emphasised where relevant. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Melorheostosis of the humerus: a rare differential diagnosis of carpal tunnel syndrome.

    PubMed

    De Vos, J; Mulliez, A; De Loore, G

    2010-04-01

    Melorheostosis is an uncommon and rare linear hyperostosis, which can be complicated by soft tissue changes. We present a case of this disorder in the humerus, clinically referred because of carpal tunnel syndrome. Although treatment is usually conservative, in this case, a neurolysis and resection of the sclerotic bone were done with good clinical result. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  18. Carpal tunnel syndrome – Part I (anatomy, physiology, etiology and diagnosis)☆☆☆

    PubMed Central

    Chammas, Michel; Boretto, Jorge; Burmann, Lauren Marquardt; Ramos, Renato Matta; dos Santos Neto, Francisco Carlos; Silva, Jefferson Braga

    2014-01-01

    Carpal tunnel syndrome (CTS) is defined by compression of the median nerve in the wrist. It is the commonest of the compressive syndromes and its most frequent cause is idiopathic. Even though spontaneous regression is possible, the general rule is that the symptoms will worsen. The diagnosis is primarily clinical, from the symptoms and provocative tests. Electroneuromyographic examination may be recommended before the operation or in cases of occupational illnesses. PMID:26229841

  19. Carpal tunnel syndrome: a complication of arteriovenous fistula in hemodialysis patients.

    PubMed Central

    Kumar, S.; Trivedi, H. L.; Smith, E. K.

    1975-01-01

    Symptoms of compression of the median nerve in the carpal tunnel developed in two patients in whom an arteriovenous fistula was created to alleviate chronic renal failure through hemodialysis. Anatomic changes in the wrist area due to the fistula are probably important in the development of this syndrome, and pre-existing uremic peripheral polyneuropathy may also be important in the early development of local symptoms of nerve damage. Images FIG. 1 PMID:1201544

  20. Finite element simulation of the mechanical impact of computer work on the carpal tunnel syndrome.

    PubMed

    Mouzakis, Dionysios E; Rachiotis, George; Zaoutsos, Stefanos; Eleftheriou, Andreas; Malizos, Konstantinos N

    2014-09-22

    Carpal tunnel syndrome (CTS) is a clinical disorder resulting from the compression of the median nerve. The available evidence regarding the association between computer use and CTS is controversial. There is some evidence that computer mouse or keyboard work, or both are associated with the development of CTS. Despite the availability of pressure measurements in the carpal tunnel during computer work (exposure to keyboard or mouse) there are no available data to support a direct effect of the increased intracarpal canal pressure on the median nerve. This study presents an attempt to simulate the direct effects of computer work on the whole carpal area section using finite element analysis. A finite element mesh was produced from computerized tomography scans of the carpal area, involving all tissues present in the carpal tunnel. Two loading scenarios were applied on these models based on biomechanical data measured during computer work. It was found that mouse work can produce large deformation fields on the median nerve region. Also, the high stressing effect of the carpal ligament was verified. Keyboard work produced considerable and heterogeneous elongations along the longitudinal axis of the median nerve. Our study provides evidence that increased intracarpal canal pressures caused by awkward wrist postures imposed during computer work were associated directly with deformation of the median nerve. Despite the limitations of the present study the findings could be considered as a contribution to the understanding of the development of CTS due to exposure to computer work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Diagnostic utility of F waves in clinically diagnosed patients of carpal tunnel syndrome.

    PubMed

    Joshi, Anand G; Gargate, Ashwini R

    2013-01-01

    Sensory nerve conduction velocity (SNCV) of median nerve measured across the carpal tunnel, difference between distal sensory latencies (DSLs) of median and ulnar nerves and difference between distal motor latencies (DMLs) of median and ulnar nerves are commonly used nerve conduction parameters for diagnosis of carpal tunnel syndrome (CTS). These are having high degree of sensitivity and specificity. Study of median nerve F-wave minimal latency (FWML) and difference between F-wave minimal latencies (FWMLs) of median and ulnar nerves have also been reported to be useful parameters for diagnosis of CTS. However, there is controversy regarding superiority of F-wave study for diagnosis of CTS. So the aim of present study was to compare sensitivity and specificity of median FWML and difference between FWMLs of median and ulnar nerves with that of above mentioned electrophysiological parameters and to find out which parameters are having more sensitivity and specificity, for early diagnosis of CTS. Median and ulnar nerves sensory and motor conduction, median and ulnar nerves F-wave studies were carried out bilaterally in 125 clinically diagnosed patients of carpal tunnel syndrome. These parameters were also studied in 45 age matched controls. Difference between DSLs of median and ulnar nerves, median SNCV and difference between DMLs of median and ulnar nerves were having highest sensitivity and specificity while median FWML and difference between FWMLs of median and ulnar nerves was having lowest sensitivity and specificity for diagnosis of CTS. So in conclusion F-wave study is not superior parameter for diagnosis of CTS.

  2. Carpal tunnel and median nerve volume changes after tunnel release in patients with the carpal tunnel syndrome: a magnetic resonance imaging (MRI) study.

    PubMed

    Crnković, T; Trkulja, V; Bilić, R; Gašpar, D; Kolundžić, R

    2016-05-01

    Our aim was to study the dynamics of the post-surgical canal and nerve volumes and their relationships to objective [electromyoneurography (EMNG)] and subjective (pain) outcomes. Forty-seven patients with carpal tunnel syndrome (CTS) (median age 52, range 23-75 years) with a prominent narrowing of the median nerve within the canal (observed during carpal tunnel release) were evaluated clinically using EMNG and magnetic resonance imagining (MRI) before and at 90 and 180 days post-surgery. Canal and nerve volumes increased, EMNG findings improved and pain resolved during the follow-up. Increase in tunnel volume was independently associated with increased nerve volume. A greater post-surgical nerve volume was independently associated with a more prominent resolution of pain, but not with the extent of EMNG improvement, whereas EMNG improvement was not associated with pain resolution. Data confirm that MRI can detect even modest changes in the carpal tunnel and median nerve volume and that tunnel release results in tunnel and nerve-volume increases that are paralleled by EMNG and clinical improvements. Taken together, these observations suggest that MRI could be used to objectivise persistent post-surgical difficulties in CTS patients. Level of evidence 3 (follow-up study).

  3. Efficacy of dietary supplement with nutraceutical composed combined with extremely-low-frequency electromagnetic fields in carpal tunnel syndrome

    PubMed Central

    Paolucci, Teresa; Piccinini, Giulia; Nusca, Sveva Maria; Marsilli, Gabriella; Mannocci, Alice; La Torre, Giuseppe; Saraceni, Vincenzo Maria; Vulpiani, Maria Chiara; Villani, Ciro

    2018-01-01

    [Purpose] The aim of this study was to investigate the clinical effects of a nutraceutical composed (Xinepa®) combined with extremely-low-frequency electromagnetic fields in the carpal tunnel syndrome. [Subjects and Methods] Thirty-one patients with carpal tunnel syndrome were randomized into group 1-A (N=16) (nutraceutical + extremely-low-frequency electromagnetic fields) and group 2-C (n=15) (placebo + extremely-low-frequency electromagnetic fields). The dietary supplement with nutraceutical was twice daily for one month in the 1-A group and both groups received extremely-low-frequency electromagnetic fields at the level of the carpal tunnel 3 times per week for 12 sessions. The Visual Analogue Scale for pain, the Symptoms Severity Scale and Functional Severity Scale of the Boston Carpal Tunnel Questionnaire were used at pre-treatment (T0), after the end of treatment (T1) and at 3 months post-treatment (T2). [Results] At T1 and T2 were not significant differences in outcome measures between the two groups. In group 1-A a significant improvement in the scales were observed at T1 and T2. In group 2-C it was observed only at T1. [Conclusion] Significant clinical effects from pre-treatment to the end of treatment were shown in both groups. Only in group 1-A they were maintained at 3 months post-treatment.

  4. Biaxial quantification of deep layer transverse carpal ligament elastic properties by sex and region.

    PubMed

    Mathers, Bryan; Agur, Anne; Oliver, Michele; Gordon, Karen

    2016-12-01

    The transverse carpal ligament is a major component of the carpal tunnel and is an important structure in the etiology of carpal tunnel syndrome. The current study aimed to quantify biaxial elastic moduli of the transverse carpal ligament and compare differences between sex and region (Radial and Ulnar). Biaxial testing of radial and ulnar samples from twenty-two (thirteen male, nine female) human fresh frozen cadaveric transverse carpal ligaments was performed. Elastic moduli and stiffness were calculated and compared. Biaxial elastic moduli of the transverse carpal ligament ranged from 0.76MPa to 3.38MPa, varying based on region (radial and ulnar), testing direction (medial-lateral and proximal-distal) and sex. Biaxial elastic moduli were significantly larger in the medial-lateral direction than the proximal-distal direction (P<0.001). Moduli were significantly larger ulnarly than radially (P=0.001). No significant differences due to gender were noted. The regional variations in biaxial elastic moduli of the transverse carpal ligament may help improve non-invasive treatment methods for carpal tunnel syndrome, specifically manipulative therapy. The smaller biaxial elastic moduli found in the radial region suggests that manipulative therapy should be focused on the radial aspect of the transverse carpal ligament. The trend where female transverse carpal ligaments had larger stiffness in the ulnar location than males suggests that that the increased prevalence of carpal tunnel syndrome in women may be related to an increased stiffness of the transverse carpal ligament, however further work is warranted to evaluate this trend. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Medical diagnosis of cubital tunnel syndrome ameliorated with thrust manipulation of the elbow and carpals

    PubMed Central

    Kearns, Gary; Wang, Sharon

    2012-01-01

    This case report describes the effectiveness of thrust manipulation to the elbow and carpals in the management of a patient referred with a medical diagnosis of cubital tunnel syndrome (CuTS). The patient was a 45-year-old woman with a 6-week history of right medial elbow pain, ulnar wrist pain, and intermittent paresthesia in the ulnar nerve distribution. Upon initial assessment, she presented with a positive elbow flexion test and upper limb neurodynamic test with ulnar nerve bias. A biomechanical assessment of the elbow and carpals revealed a loss of lateral glide of the humerus on the ulna and a loss of palmar glide of the triquetral on the hamate. After the patient received two thrust manipulations of the elbow and one thrust manipulation of the carpals over the course of four sessions, her pain and paresthesia were resolved. This case demonstrates that the use of thrust manipulation to the elbow and carpals may be an effective approach in the management of insidious onset CuTS. This patient was successfully treated with thrust manipulation when joint dysfunction of the elbow and wrist were appropriately identified. This case report may shed light on the examination and management of insidious onset CuTS. PMID:23633888

  6. [Clinical and electrophysiological findings in carpal tunnel syndrome].

    PubMed

    Kohara, Nobuo

    2007-11-01

    Carpal tunnel syndrome (CTS) is the most common nerve entrapment disorder. The clinical features of CTS are variable, but usually include pain and paresthesia in the thumb, first two fingers, and the radial-half of the ring finger. Paresthesia and sensory deficits might involve the entire palm area in some cases. Pain frequently radiate proximally into the forearm, and occasionally to the shoulder. Many patients experience pain at night and are awakened by abnormal sensations. Shaking hand relief the symptom. The two classic tests for nerve compression at the wrist are the Tinel test and the Phalen maneuver, which diagnostic value is limited. Golden standard for the diagnosis is the combination of the clinical findings and the electrophysiological study. Routine median nerve conduction study is valuable. Prolonged terminal latency of motor or sensory nerve would be found in most CTS hands. If the routine study showed equivocal, more sensitive methods are needed. Those include segmental sensory conduction study across the carpal tunnel by median stimulation at midpalm, a comparison of median and ulnar sensory nerve latencies at ring finger and a comparison of median and radial sensory nerve latencies at thumb. A difference between the median motor latency to the second lumbrical and the ulnar motor latency to the interossei muscles has also diagnostic value in some cases. In addition, inching method can localized the compression site. Using these techniques, the diagnosis of CTS would become more reliable.

  7. Bilateral hand/wrist heat and cold hyperalgesia, but not hypoesthesia, in unilateral carpal tunnel syndrome.

    PubMed

    de la Llave-Rincón, Ana Isabel; Fernández-de-las-Peñas, César; Fernández-Carnero, Josué; Padua, Luca; Arendt-Nielsen, Lars; Pareja, Juan A

    2009-10-01

    The aim of the current study was to evaluate bilaterally warm/cold detection and heat/cold pain thresholds over the hand/wrist in patients with carpal tunnel syndrome (CTS). A total of 25 women with strictly unilateral CTS (mean 42 +/- 10 years), and 20 healthy matched women (mean 41 +/- 8 years) were recruited. Warm/cold detection and heat/cold pain thresholds were assessed bilaterally over the carpal tunnel and the thenar eminence in a blinded design. Self-reported measures included both clinical pain history (intensity, location and area) and Boston Carpal Tunnel Questionnaire. No significant differences between groups for both warm and cold detection thresholds in either carpal tunnel or thenar eminence (P > 0.5) were found. Further, significant differences between groups, but not between sides, for both heat and cold pain thresholds in both the carpal tunnel and thenar eminence were found (all P < 0.001). Heat pain thresholds (P < 0.01) were negatively correlated, whereas cold pain thresholds (P < 0.001) were positively correlated with hand pain intensity and duration of symptoms. Our findings revealed bilateral thermal hyperalgesia (lower heat pain and reduced cold pain thresholds) but not hypoesthesia (normal warm/cold detection thresholds) in patients with strictly unilateral CTS when compared to controls. We suggest that bilateral heat and cold hyperalgesia may reflect impairments in central nociceptive processing in patients with unilateral CTS. The bilateral thermal hyperalgesia associated with pain intensity and duration of pain history supports a role of generalized sensitization mechanisms in the initiation, maintenance and spread of pain in CTS.

  8. [The carpal tunnel syndrome in the oil toxic syndrome].

    PubMed

    Estirado De Cabo, E; Plaza Cano, M M; García De Aguinaga, M L; Fuertes Rodríguez, P; Ferrari Arroyo, M J; Izquierdo Martínez, M; Posada De La Paz, M

    2002-02-01

    The toxic oil syndrome (TOS) is an autoimmune disease caused by the ingestion of aniline-denatured rapeseed oil. The carpal tunnel syndrome (CTS) is an entrapment neuropathy due to the median nerve entrapment, which is associated with both occupational activities and autoimmune diseases. The objective of this work was to know the frequency and characteristics of CTS in TOS patients. Between December 1977 and July 2000, 744 TOS patients were evaluated. The inclusion criteria were: the clinical records for patients diagnosed between May 1981 and November 1997; and for patients diagnosed between December 1997 and July 2000, symptoms with the classical or likely pattern according to the Katz's hand diagram and one of the following findings: a) abnormal electromyogram, and b) hypalgesia in the median nerve territory and positive Tinel and/or Phalen signs. A total of 70 patients (63 women, 90%) were diagnosed; 48 of them had been diagnosed before 1997 and 22 subsequently. The mean age of patients was 47.6 (20-78) years. In 36 patients (51.4%), a bilateral CTS was present. Fifty-six patients (81.4%) had a diagnostic EMG, and 31 (44.2%) were obese, 13 (18.6%) diabetic, and 4 (6%) had hypothyroidism. Most of these cases (48; 68.6%) were housewives. TOS patients have a high frequency of CTS; therefore, this condition must be suspected in patients with associated obesity and diabetes mellitus.

  9. The relationship between preoperative needle electromyography findings and muscle power restoration after surgery in severe carpal tunnel syndrome patients.

    PubMed

    Hara, Yuki; Nishiura, Yasumasa; Ochiai, Naoyuki; Murai, Shinji; Yamazaki, Masashi

    2017-05-01

    Needle electromyography provides essential information about the functional aspects of the muscle. But little attention has been given in the literature to needle electromyography examinations in carpal tunnel syndrome. We examined the relationship between preoperative needle electromyography findings and functional recovery of the abductor pollicis brevis (APB) muscle in severe carpal tunnel syndrome patients. The subjects of this study were 49 patients, 58 hands, who fit the following 5 criteria: (1) idiopathic carpal tunnel syndrome; (2) pre-op MMT grade of the APB muscle was M0 or M1; (3) APB-CMAP (compound muscle action potential) was not evoked in a median nerve conduction study; (4) needle electromyography of the APB muscle had been done; (5) underwent carpal tunnel release only. The patients were divided into two groups according to the results of pre-op needle electromyography: voluntary motor unit potential of the APB muscle was evoked [MUP(+) group]or not [MUP(-) group]. We evaluated APB muscle strength at one year after surgery, and patient satisfaction and functional evaluations (CTSI-FS) at more than one year after. The APB muscle recovery rate to M3 or higher was 100% in the MUP(+) group, and 57% in the MUP(-) group. Patient satisfaction was also high and functional recovery was sufficient in the MUP(+) group. No patients requested a second opponensplasty. Our findings suggest that post-op restoration of thumb function relates to whether or not the MUP ofthe APB muscle is evoked. Single-stage opponensplasty may be unnecessary if the MUP of the APB muscle is; evoked. Needle electromyography is therefore useful in consideration for opponensplasty. Level Ⅲ, case-control study. Copyright © 2017. Published by Elsevier B.V.

  10. Risk factors for operated carpal tunnel syndrome: a multicenter population-based case-control study

    PubMed Central

    Mattioli, Stefano; Baldasseroni, Alberto; Bovenzi, Massimo; Curti, Stefania; Cooke, Robin MT; Campo, Giuseppe; Barbieri, Pietro G; Ghersi, Rinaldo; Broccoli, Marco; Cancellieri, Maria Pia; Colao, Anna Maria; dell'Omo, Marco; Fateh-Moghadam, Pirous; Franceschini, Flavia; Fucksia, Serenella; Galli, Paolo; Gobba, Fabriziomaria; Lucchini, Roberto; Mandes, Anna; Marras, Teresa; Sgarrella, Carla; Borghesi, Stefano; Fierro, Mauro; Zanardi, Francesca; Mancini, Gianpiero; Violante, Francesco S

    2009-01-01

    Background Carpal tunnel syndrome (CTS) is a socially and economically relevant disease caused by compression or entrapment of the median nerve within the carpal tunnel. This population-based case-control study aims to investigate occupational/non-occupational risk factors for surgically treated CTS. Methods Cases (n = 220) aged 18-65 years were randomly drawn from 13 administrative databases of citizens who were surgically treated with carpal tunnel release during 2001. Controls (n = 356) were randomly sampled from National Health Service registry records and were frequency matched by age-gender-specific CTS hospitalization rates. Results At multivariate analysis, risk factors were blue-collar/housewife status, BMI ≥ 30 kg/m2, sibling history of CTS and coexistence of trigger finger. Being relatively tall (cut-offs based on tertiles: women ≥165 cm; men ≥175 cm) was associated with lower risk. Blue-collar work was a moderate/strong risk factor in both sexes. Raised risks were apparent for combinations of biomechanical risk factors that included frequent repetitivity and sustained force. Conclusion This study strongly underlines the relevance of biomechanical exposures in both non-industrial and industrial work as risk factors for surgically treated CTS. PMID:19758429

  11. Effects of traditional cupping therapy in patients with carpal tunnel syndrome: a randomized controlled trial.

    PubMed

    Michalsen, Andreas; Bock, Silke; Lüdtke, Rainer; Rampp, Thomas; Baecker, Marcus; Bachmann, Jürgen; Langhorst, Jost; Musial, Frauke; Dobos, Gustav J

    2009-06-01

    We investigated the effectiveness of cupping, a traditional method of treating musculoskeletal pain, in patients with carpal tunnel syndrome (CTS) in an open randomized trial. n = 52 outpatients (58.5 +/- 8.0 years) with neurologically confirmed CTS were randomly assigned to either a verum (n = 26) or a control group (n = 26). Verum patients were treated with a single application of wet cupping, and control patients with a single local application of heat within the region overlying the trapezius muscle. Patients were followed up on day 7 after treatment. The primary outcome, severity of CTS symptoms (VAS), was reduced from 61.5 +/- 20.5 to 24.6 +/- 22.7 mm at day 7 in the cupping group and from 67.1 +/- 20.2 to 51.7 +/- 23.9 mm in the control group [group difference -24.5mm (95%CI -36.1; -2.9, P < .001)]. Significant treatment effects were also found for the Levine CTS-score (-.6 pts: 95%CI -.9; -.2, P = .002), neck pain (-12.6mm; 95%CI -18.8; -6.4, P < .001), functional disability (DASH-Score) (-11.1 pts; 95%CI -17.1; -5.1, P < .001), and physical quality of life (.3; 95%CI .0; .3, P = .048). The treatment was safe and well tolerated. We conclude that cupping therapy may be effective in relieving the pain and other symptoms related to CTS. The efficacy of cupping in the long-term management of CTS and related mechanisms remains to be clarified. The results of a randomized trial on the clinical effects of traditional cupping therapy in patients with carpal tunnel syndrome are presented. Cupping of segmentally related shoulder zones appears to alleviate the symptoms of carpal tunnel syndrome.

  12. Identification of Subgroups of Women with Carpal Tunnel Syndrome with Central Sensitization.

    PubMed

    Fernández-de-Las-Peñas, César; Fernández-Muñoz, Juan J; Navarro-Pardo, Esperanza; da-Silva-Pocinho, Ricardo F; Ambite-Quesada, Silvia; Pareja, Juan A

    2016-09-01

    Identification of subjects with different sensitization mechanisms can help to identify better therapeutic strategies for carpal tunnel syndrome (CTS). The aim of the current study was to identify subgroups of women with CTS with different levels of sensitization. A total of 223 women with CTS were recruited. Self-reported variables included pain intensity, function, disability, and depression. Pressure pain thresholds (PPT) were assessed bilaterally over median, ulnar, and radial nerves, C5-C6 joint, carpal tunnel, and tibialis anterior to assess widespread pressure pain hyperalgesia. Heat (HPT) and cold (CPT) pain thresholds were also bilaterally assessed over the carpal tunnel and the thenar eminence to determine thermal pain hyperalgesia. Pinch grip force between the thumb and the remaining fingers was calculated to determine motor assessment. Subgroups were determined according to the status on a previous clinical prediction rule: PPT over the affected C5-C6 joint < 137 kPa, HPT on affected carpal tunnel <39.6ºC, and general health >66 points. The ANOVA showed that women within group 1 (positive rule, n = 60) exhibited bilateral widespread pressure hyperalgesia (P < 0.001) and bilateral thermal thresholds (P < 0.001) than those within group 2 (negative rule, n = 162). Women in group 1 also exhibited higher depression than those in group 2 (P = 0.023). No differences in self-reported variables were observed. This study showed that a clinical prediction rule originally developed for identifying women with CTS who are likely to respond favorably to manual physical therapy was able to identify women exhibiting higher widespread pressure hyper-sensitivity and thermal hyperalgesia. This subgroup of women with CTS exhibiting higher sensitization may need specific therapeutic programs. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Examination of patients for carpal tunnel syndrome sensibility, provocative, and motor testing.

    PubMed

    Palumbo, Carl F; Szabo, Robert M

    2002-05-01

    The value of a test for carpal tunnel syndrome (CTS) depends on the purpose of performing the test. When screening a large population with a low prevalence for CTS, a test with a high sensitivity is needed so that no possible case goes undetected. However, in order to establish a diagnosis, a more specific test is required. Using a combination of physical examination techniques, including sensibility and provocative testing, the probability of correctly diagnosing CTS without relying on electrodiagnostic studies can be very high. Because CTS is a clinical syndrome, the diagnosis should be made on clinical grounds. Electrodiagnosis is extremely important, however, in its ability to objectively document median nerve slowing and eliminate other competing differential diagnoses.

  14. Hand pain other than carpal tunnel syndrome (CTS): the role of occupational factors.

    PubMed

    Andréu, José-Luis; Otón, Teresa; Silva-Fernández, Lucía; Sanz, Jesús

    2011-02-01

    Some occupational factors have been implicated in the development of disorders manifested as hand pain. The associations seem to be well documented in processes such as hand-arm vibration syndrome (HAVS) or writer's cramp. There are contradictory data in the literature about the relationships of trigger finger, De Quervain's tenosynovitis (DQT) and tenosynovitis of the wrist with occupational factors. In this article, we review current knowledge about clinical manifestations, case definition, implicated occupational factors, diagnosis and treatment of the most relevant hand pain disorders that have been associated with occupational factors, excluding carpal tunnel syndrome (CTS). Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Mild leptospirosis with three-year persistence of IgG- and IgM-antibodies, initially manifesting as carpal tunnel syndrome.

    PubMed

    Finsterer, Josef; Stöllberger, Claudia; Sehnal, Ernst; Stanek, Gerold

    2005-08-01

    Long-term persistence of IgG- and IgM-antibodies against leptospira after mild leptospirosis has not been reported. In a 45-year-old female pet-shop worker with carpal tunnel syndrome, accompanied by arthralgias, coughing, repeatedly elevated temperature, followed by easy fatigability, personality change, memory and speech disturbance, blurred vision, myalgia and swollen lymph nodes, leptospirosis was diagnosed, based upon history, clinical findings, and serological investigations. After the described symptoms had disappeared following doxycyclin for 2 weeks, IgG- and IgM-antibodies against leptospira remained positive during the next three years. This case illustrates that leptospirosis may start as carpal tunnel syndrome and that the severity of leptospirosis does not seem to be related to the intensity of the humoral immune response against the causative agent.

  16. Pain is Associated to Clinical, Psychological, Physical, and Neurophysiological Variables in Women With Carpal Tunnel Syndrome.

    PubMed

    Fernández-Muñoz, Juan J; Palacios-Ceña, María; Cigarán-Méndez, Margarita; Ortega-Santiago, Ricardo; de-la-Llave-Rincón, Ana I; Salom-Moreno, Jaime; Fernández-de-las-Peñas, César

    2016-02-01

    To investigate potential relationships of clinical (age, function, side of pain, years with pain), physical (cervical range of motion, pinch grip force), psychological (depression), and neurophysiological (pressure and thermal pain thresholds) outcomes and hand pain intensity in carpal tunnel syndrome (CTS). Two hundred and forty-four (n=224) women with CTS were recruited. Demographic data, duration of the symptoms, function and severity of the disease, pain intensity, depression, cervical range of motion, pinch tip grip force, heat/cold pain thresholds (HPT/CPT), and pressure pain thresholds (PPT) were collected. Correlation and regression analysis were performed to determine the association among those variables and to determine the proportions of explained variance in hand pain intensity. Significant negative correlations existed between the intensity of pain and PPTs over the radial nerve, C5/C6 zygapophyseal joint, carpal tunnel and tibialis anterior muscle, HPT over the carpal tunnel, cervical extension and lateral-flexion, and thumb-middle, fourth, and little finger pinch tip forces. Significant positive correlations between the intensity of hand pain with function and depression were also observed. Stepwise regression analyses revealed that function, thumb-middle finger pinch, thumb-little finger pinch, depression, PPT radial nerve, PPT carpal tunnel, and HPT carpal tunnel were significant predictors of intensity of hand pain (R²=0.364; R² adjusted=0.343; F=16.87; P<0.001). This study showed that 36.5% of the variance of pain intensity was associated to clinical (function), neurophysiological (localized PPT and HPT), psychological (depression), and physical (finger pinch tip force) outcomes in women with chronic CTS.

  17. Multidimensional Ultrasound Imaging of the Wrist: Changes of Shape and Displacement of the Median Nerve and Tendons in Carpal Tunnel Syndrome

    PubMed Central

    Filius, Anika; Scheltens, Marjan; Bosch, Hans G.; van Doorn, Pieter A.; Stam, Henk J.; Hovius, Steven E.R.; Amadio, Peter C.; Selles, Ruud W.

    2015-01-01

    Dynamics of structures within the carpal tunnel may alter in carpal tunnel syndrome (CTS) due to fibrotic changes and increased carpal tunnel pressure. Ultrasound can visualize these potential changes, making ultrasound potentially an accurate diagnostic tool. To study this, we imaged the carpal tunnel of 113 patients and 42 controls. CTS severity was classified according to validated clinical and nerve conduction study (NCS) classifications. Transversal and longitudinal displacement and shape (changes) were calculated for the median nerve, tendons and surrounding tissue. To predict diagnostic value binary logistic regression modeling was applied. Reduced longitudinal nerve displacement (p≤0.019), increased nerve cross-sectional area (p≤0.006) and perimeter (p≤0.007), and a trend of relatively changed tendon displacements were seen in patients. Changes were more convincing when CTS was classified as more severe. Binary logistic modeling to diagnose CTS using ultrasound showed a sensitivity of 70-71% and specificity of 80-84%. In conclusion, CTS patients have altered dynamics of structures within the carpal tunnel. PMID:25865180

  18. Increased pain sensitivity is not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    PubMed

    de la Llave-Rincón, Ana Isabel; Fernández-de-las-Peñas, César; Laguarta-Val, Sofia; Alonso-Blanco, Cristina; Martínez-Perez, Almudena; Arendt-Nielsen, Lars; Pareja, Juan A

    2011-01-01

    To determine the differences in widespread pressure pain and thermal hypersensitivity in women with minimal, moderate, and severe carpal tunnel syndrome (CTS) and healthy controls. A total of 72 women with CTS (19 with minimal, 18 with moderate, and 35 with severe) and 19 healthy age-matched women participated. Pressure pain thresholds were bilaterally assessed over the median, ulnar, and radial nerves, the C5 to C6 zygapophyseal joint, the carpal tunnel, and the tibialis anterior muscle. In addition, warm and cold detection thresholds and heat and cold pain thresholds were bilaterally assessed over the carpal tunnel and the thenar eminence. All outcome parameters were assessed by an assessor blinded to the participant's condition. No significant differences in pain parameters among patients with minimal, moderate, and severe CTS were found. The results showed that PPT were significantly decreased bilaterally over the median, ulnar, and radial nerve trunks, the carpal tunnel, C5 to C6 zygapophyseal joint, and the tibialis anterior muscle in patients with minimal, moderate, or severe CTS as compared with healthy controls (all, P<0.001). In addition, patients with CTS also showed lower heat pain threshold and reduced cold pain threshold compared with controls (P<0.001). No significant sensory differences between minimal, moderate, or severe CTS were found. The similar widespread pressure and thermal hypersensitivity in patients with minimal, moderate, or severe CTS and pain intensity suggests that increased pain sensitivity is not related to electrodiagnostic findings.

  19. Static Magnetic Field Therapy for Carpal Tunnel Syndrome: A Feasibility Study

    PubMed Central

    Colbert, Agatha P.; Markov, Marko S.; Carlson, Nels; Gregory, William L.; Carlson, Hans; Elmer, Patricia J.

    2010-01-01

    Objectives To assess the feasibility of conducting trials of static magnetic field (SMF) therapy for carpal tunnel syndrome (CTS), to collect preliminary data on the effectiveness of two SMF dosages and to explore the influence of a SMF on median nerve conduction. Design Randomized, double blind, sham controlled trial with 6-week intervention and 12-week follow-up. Setting University hospital outpatient clinics Participants Women and men (N=60), ages 21–65, with electrophysiologically-confirmed CTS diagnosis, recruited from the general population. Interventions Participants wore nightly either neodymium magnets that delivered either 15 or 45mTesla (mT) to the contents of the carpal canal, or a non-magnetic disk. Main Outcome Measures Symptom Severity Scale (SSS) and Function Severity Scale (FSS) of the Boston Carpal Tunnel Questionnaire (BCTQ) and 4 median nerve parameters: sensory distal latency, sensory nerve action potential amplitude, motor distal latency and compound motor action potential amplitude). Results 58 of 60 randomized participants completed the study. There were no significant between-group differences for change in the primary endpoint SSS or for FSS or median nerve conduction parameters. For the SSS and the FSS each group showed a reduction at 6-weeks indicating improvement in symptoms. Conclusions This study demonstrated the feasibility and safety of testing SMF therapy for CTS. There were no between-group differences observed for the BCTQ or median nerve parameters following 6 weeks of SMF therapy. Significant within-group, symptomatic improvements of the same magnitude were experienced by participants in both active and sham magnet groups. Future studies are needed to optimize SMF dosimetry and resolve issues related to the use of sham controls in SMF trials. PMID:20599049

  20. Effectiveness of manual therapy versus surgery in pain processing due to carpal tunnel syndrome: A randomized clinical trial.

    PubMed

    Fernández-de-Las-Peñas, C; Cleland, J; Palacios-Ceña, M; Fuensalida-Novo, S; Alonso-Blanco, C; Pareja, J A; Alburquerque-Sendín, F

    2017-08-01

    People with carpal tunnel syndrome (CTS) exhibit widespread pressure pain and thermal pain hypersensitivity as a manifestation of central sensitization. The aim of our study was to compare the effectiveness of manual therapy versus surgery for improving pain and nociceptive gain processing in people with CTS. The trial was conducted at a local regional Hospital in Madrid, Spain from August 2014 to February 2015. In this randomized parallel-group, blinded, clinical trial, 100 women with CTS were randomly allocated to either manual therapy (n = 50), who received three sessions (once/week) of manual therapies including desensitization manoeuvres of the central nervous system, or surgical intervention (n = 50) group. Outcomes including pressure pain thresholds (PPT), thermal pain thresholds (HPT or CPT), and pain intensity which were assessed at baseline, and 3, 6, 9 and 12 months after the intervention by an assessor unaware of group assignment. Analysis was by intention to treat with mixed ANCOVAs adjusted for baseline scores. At 12 months, 95 women completed the follow-up. Patients receiving manual therapy exhibited higher increases in PPT over the carpal tunnel at 3, 6 and 9 months (all, p < 0.01) and higher decrease of pain intensity at 3 month follow-up (p < 0.001) than those receiving surgery. No significant differences were observed between groups for the remaining outcomes. Manual therapy and surgery have similar effects on decreasing widespread pressure pain sensitivity and pain intensity in women with CTS. Neither manual therapy nor surgery resulted in changes in thermal pain sensitivity. The current study found that manual therapy and surgery exhibited similar effects on decreasing widespread pressure pain sensitivity and pain intensity in women with carpal tunnel syndrome at medium- and long-term follow-ups investigating changes in nociceptive gain processing after treatment in carpal tunnel syndrome. © 2017 European Pain Federation - EFIC®.

  1. Pictorial essay: Role of ultrasound in failed carpal tunnel decompression.

    PubMed

    Botchu, Rajesh; Khan, Aman; Jeyapalan, Kanagaratnam

    2012-01-01

    USG has been used for the diagnosis of carpal tunnel syndrome. Scarring and incomplete decompression are the main causes for persistence or recurrence of symptoms. We performed a retrospective study to assess the role of ultrasound in failed carpal tunnel decompression. Of 422 USG studies of the wrist performed at our center over the last 5 years, 14 were for failed carpal tunnel decompression. Scarring was noted in three patients, incomplete decompression in two patients, synovitis in one patient, and an anomalous muscle belly in one patient. No abnormality was detected in seven patients. We present a pictorial review of USG findings in failed carpal tunnel decompression.

  2. Pictorial essay: Role of ultrasound in failed carpal tunnel decompression

    PubMed Central

    Botchu, Rajesh; Khan, Aman; Jeyapalan, Kanagaratnam

    2012-01-01

    USG has been used for the diagnosis of carpal tunnel syndrome. Scarring and incomplete decompression are the main causes for persistence or recurrence of symptoms. We performed a retrospective study to assess the role of ultrasound in failed carpal tunnel decompression. Of 422 USG studies of the wrist performed at our center over the last 5 years, 14 were for failed carpal tunnel decompression. Scarring was noted in three patients, incomplete decompression in two patients, synovitis in one patient, and an anomalous muscle belly in one patient. No abnormality was detected in seven patients. We present a pictorial review of USG findings in failed carpal tunnel decompression. PMID:22623813

  3. Electroacupuncture and splinting versus splinting alone to treat carpal tunnel syndrome: a randomized controlled trial.

    PubMed

    Chung, Vincent C H; Ho, Robin S T; Liu, Siya; Chong, Marc K C; Leung, Albert W N; Yip, Benjamin H K; Griffiths, Sian M; Zee, Benny C Y; Wu, Justin C Y; Sit, Regina W S; Lau, Alexander Y L; Wong, Samuel Y S

    2016-09-06

    The effectiveness of acupuncture for managing carpal tunnel syndrome is uncertain, particularly in patients already receiving conventional treatments (e.g., splinting). We aimed to assess the effects of electroacupuncture combined with splinting. We conducted a randomized parallel-group assessor-blinded 2-arm trial on patients with clinically diagnosed primary carpal tunnel syndrome. The treatment group was offered 13 sessions of electroacupuncture over 17 weeks. The treatment and control groups both received continuous nocturnal wrist splinting. Of 181 participants randomly assigned to electroacupuncture combined with splinting (n = 90) or splinting alone (n = 91), 174 (96.1%) completed all follow-up. The electroacupuncture group showed greater improvements at 17 weeks in symptoms (primary outcome of Symptom Severity Scale score mean difference [MD] -0.20, 95% confidence interval [CI] -0.36 to -0.03), disability (Disability of Arm, Shoulder and Hand Questionnaire score MD -6.72, 95% CI -10.9 to -2.57), function (Functional Status Scale score MD -0.22, 95% CI -0.38 to -0.05), dexterity (time to complete blinded pick-up test MD -6.13 seconds, 95% CI -10.6 to -1.63) and maximal tip pinch strength (MD 1.17 lb, 95% CI 0.48 to 1.86). Differences between groups were small and clinically unimportant for reduction in pain (numerical rating scale -0.70, 95% CI -1.34 to -0.06), and not significant for sensation (first finger monofilament test -0.08 mm, 95% CI -0.22 to 0.06). For patients with primary carpal tunnel syndrome, chronic mild to moderate symptoms and no indication for surgery, electroacupuncture produces small changes in symptoms, disability, function, dexterity and pinch strength when added to nocturnal splinting. Chinese Clinical Trial Register no. ChiCTR-TRC-11001655 (www.chictr.org.cn/showprojen.aspx?proj=7890); subsequently deposited in the World Health Organization International Clinical Trials Registry Platform (apps.who.int/trialsearch/Trial2.aspx

  4. Validation of the Japanese Society for Surgery of the Hand version of the Carpal Tunnel Syndrome Instrument.

    PubMed

    Imaeda, Toshihiko; Uchiyama, Shigeharu; Toh, Satoshi; Wada, Takuro; Okinaga, Shuji; Sawaizumi, Takuya; Nishida, Jun; Kusunose, Koichi; Omokawa, Shohei

    2007-01-01

    The Carpal Tunnel Syndrome Instrument (CTSI) is a disease-specific, self-administered questionnaire that consists of a symptom severity scale (SS) and a functional status scale (FS). The CTSI was cross-culturally adapted and developed by the Impairment Evaluation Committee, Japanese Society for Surgery of the Hand (JSSH). The purpose of this study was to test the reliability, validity, and responsiveness of the Japanese version of the CTSI (CTSI-JSSH). A consecutive series of 87 patients with carpal tunnel syndrome completed the CTSI-JSSH, the JSSH version of the Disability of the Arm, Shoulder, and Hand questionnaire (DASH-JSSH), and the 36-Item Short-Form Health Survey (SF-36). Seventy-two of the patients were reassessed for test-retest reliability 1 or 2 weeks later. Reliability was investigated by the reproducibility and the internal consistency. To analyze the validity, a factor analysis (principal axis factoring) of the CTSI-JSSH and the correlation coefficients between the CTSI-JSSH and DASH-JSSH were obtained. The responsiveness was examined by calculating the standardized response mean (SRM; mean change/SD) and effect size (mean change/SD of baseline value) after carpal tunnel release in 42 patients. Cronbach's alpha coefficients for the CTSI-JSSH-SS and the CTSI-JSSH-FS were 0.84 and 0.90, respectively, and the intraclass correlation coefficients were 0.82 and 0.83, respectively. The unidimensionality of the CTSI-JSSH-SS was barely confirmed; the unidimensionality of the CTSI-JSSH-FS was confirmed. The correlation coefficients between the CTSI-JSSH-FS and the CTSI-JSSH-SS or DASH-JSSH were 0.58 and 0.80, respectively. The correlation coefficient between the CTSI-JSSH-SS and DASH-JSSH was 0.54. The correlation coefficients between the subscales of SF-36 and the CTSI-JSSH-SS or the CTSI-JSSH-FS ranged from -0.23 to -0.66 and from -0.19 to -0.63, respectively. The SRMs/effect sizes of the CTSI-JSSH-SS and the CTSI-JSSH-FS were -0.85/-0.99 and -0

  5. Carpal tunnel syndrome in the Turkish steel industry.

    PubMed

    Gedizlioglu, Muhtesem; Arpaci, Esra; Cevher, Demet; Ce, Pinar; Kulan, Can Ahmet; Colak, Ilhan; Duzgun, Baran

    2008-05-01

    Certain occupations are reported to be associated with a high risk for carpal tunnel syndrome (CTS). In this study, we investigated the development of CTS in iron-steel industry workers. Subjects were recruited from a factory of 650 workers and assessed by means of history, physical examination and electrophysiological testing. Seventy-nine subjects from the factory and 53 healthy controls with occupations unrelated to heavy physical work were assessed. None of the worker group had electrophysiological evidence of CTS. One subject in the control group has electrophysiological evidence of CTS. In the worker group, all sensory nerve conduction velocities and ulnar nerve action potential amplitudes in both hands and distal motor latencies were statistically different. In our study, among a group of heavy labourers, no cases of CTS were detected. However, all electrophysiologic parameters of workers were different from controls. Our results point to a diffuse, but subclinical injury of peripheral nerves under heavy physical work conditions, instead of a local effect such as CTS.

  6. Tensile properties of the transverse carpal ligament and carpal tunnel complex.

    PubMed

    Ugbolue, Ukadike C; Gislason, Magnus K; Carter, Mark; Fogg, Quentin A; Riches, Philip E; Rowe, Philip J

    2015-08-01

    A new sophisticated method that uses video analysis techniques together with a Maillon Rapide Delta to determine the tensile properties of the transverse carpal ligament-carpal tunnel complex has been developed. Six embalmed cadaveric specimens amputated at the mid-forearm and aged (mean (SD)): 82 (6.29) years were tested. The six hands were from three males (four hands) and one female (two hands). Using trigonometry and geometry the elongation and strain of the transverse carpal ligament and carpal arch were calculated. The cross-sectional area of the transverse carpal ligament was determined. Tensile properties of the transverse carpal ligament-carpal tunnel complex and Load-Displacement data were also obtained. Descriptive statistics, one-way ANOVA together with a post-hoc analysis (Tukey) and t-tests were incorporated. A transverse carpal ligament-carpal tunnel complex novel testing method has been developed. The results suggest that there were no significant differences between the original transverse carpal ligament width and transverse carpal ligament at peak elongation (P=0.108). There were significant differences between the original carpal arch width and carpal arch width at peak elongation (P=0.002). The transverse carpal ligament failed either at the mid-substance or at their bony attachments. At maximum deformation the peak load and maximum transverse carpal ligament displacements ranged from 285.74N to 1369.66N and 7.09mm to 18.55mm respectively. The transverse carpal ligament cross-sectional area mean (SD) was 27.21 (3.41)mm(2). Using this method the results provide useful biomechanical information and data about the tensile properties of the transverse carpal ligament-carpal tunnel complex. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. [Carpal tunnel syndrome and steel industry].

    PubMed

    Caciari, T; Rosati, M V; Casale, T; Sancini, A; Giubilati, R; De Sio, S; Suppi, A; Tomei, G; Santoro, L; Scala, B; Nardone, N; Tomei, F

    2013-01-01

    The carpal tunnel syndrome (CTS) is a common working pathology. The CTS diagnosis is not so easy because neurophysiological investigations are necessary. The purpose of this study is to evaluate the working risks and the presence of CTS signs using a focused anamnestic and clinical procedure. We evaluated the working risks of CTS in a population of 65 male workers of a steel industry (average age 25.1 and seniority 2.82), performing 5 different tasks. The Borg Scale was used to evaluate the subjective muscle effort. Diurnal paresthesia (V1FG), nocturnal paresthesia (V1FN), hypersensitivity (V1IS), hypostenia (V1IT) were considered. We identified three main working risks repetitiveness of single actions, static and prolonged posture of the truck, muscle effort. 21.5% of the workers showed at least one of the three symptoms;13.8% showed one or more symptoms; the clinical objectivity was observed in 18.5%. A relation between V1FG, V1FN, clinical objective linked to the workers age of the task 1 (p =0.035) is showed. To prevent CTS, the use of the Borg Scale associated with identification of the risks and with the anamenstic-clinical investigation is useful to discriminate people at risk of CTS.

  8. Steel syndrome: dislocated hips and radial heads, carpal coalition, scoliosis, short stature, and characteristic facial features.

    PubMed

    Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S

    2010-01-01

    A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.

  9. [Evaluation of motor and sensory neuroconduction of the median nerve in patients with carpal tunnel syndrome treated with non-coherent light emitted by gallium arsenic diodes].

    PubMed

    Viera Alemán, C; Purón, E; Hamilton, M L; Santos Anzorandia, C; Navarro, A; Pineda Ortiz, I

    The treatment selection in the carpal tunnel syndrome according to the damage of the median nerve is important and all of these have adverse effects. A good alternative without undesired reactions is irradiation of the carpal tunnel with not coherent light between 920 and 940 nm emitted by gallium arsenide diodes, resembling the physic and therapeutic laser effects. Twenty-six female patients with idiopathic middle carpal tunnel syndrome were irradiated 15 minutes daily during three weeks. The median nerve motor and sensitive neuroconduction was studied before and immediately after the treatment. The abnormal neuroconduction variables (latency, amplitude and velocity conduction) did not modify when treatment concluded, in spite of all the patients reported disappearance of pain and numbness in damaged hands. Not coherent light does not change the fibers functional state explored by conventional neuroconductions techniques. It remains to know if this light produces fine fibers improvement.

  10. Electroacupuncture and splinting versus splinting alone to treat carpal tunnel syndrome: a randomized controlled trial

    PubMed Central

    Chung, Vincent C.H.; Ho, Robin S.T.; Liu, Siya; Chong, Marc K.C.; Leung, Albert W.N.; Yip, Benjamin H.K.; Griffiths, Sian M.; Zee, Benny C.Y.; Wu, Justin C.Y.; Sit, Regina W.S.; Lau, Alexander Y.L.; Wong, Samuel Y.S.

    2016-01-01

    Background: The effectiveness of acupuncture for managing carpal tunnel syndrome is uncertain, particularly in patients already receiving conventional treatments (e.g., splinting). We aimed to assess the effects of electroacupuncture combined with splinting. Methods: We conducted a randomized parallel-group assessor-blinded 2-arm trial on patients with clinically diagnosed primary carpal tunnel syndrome. The treatment group was offered 13 sessions of electroacupuncture over 17 weeks. The treatment and control groups both received continuous nocturnal wrist splinting. Results: Of 181 participants randomly assigned to electroacupuncture combined with splinting (n = 90) or splinting alone (n = 91), 174 (96.1%) completed all follow-up. The electroacupuncture group showed greater improvements at 17 weeks in symptoms (primary outcome of Symptom Severity Scale score mean difference [MD] −0.20, 95% confidence interval [CI] −0.36 to −0.03), disability (Disability of Arm, Shoulder and Hand Questionnaire score MD −6.72, 95% CI −10.9 to −2.57), function (Functional Status Scale score MD −0.22, 95% CI −0.38 to −0.05), dexterity (time to complete blinded pick-up test MD −6.13 seconds, 95% CI −10.6 to −1.63) and maximal tip pinch strength (MD 1.17 lb, 95% CI 0.48 to 1.86). Differences between groups were small and clinically unimportant for reduction in pain (numerical rating scale −0.70, 95% CI −1.34 to −0.06), and not significant for sensation (first finger monofilament test −0.08 mm, 95% CI −0.22 to 0.06). Interpretation: For patients with primary carpal tunnel syndrome, chronic mild to moderate symptoms and no indication for surgery, electroacupuncture produces small changes in symptoms, disability, function, dexterity and pinch strength when added to nocturnal splinting. Trial registration: Chinese Clinical Trial Register no. ChiCTR-TRC-11001655 (www.chictr.org.cn/showprojen.aspx?proj=7890); subsequently deposited in the World Health

  11. Er:YAG laser for the surgical treatment of the carpal tunnel syndrome

    NASA Astrophysics Data System (ADS)

    Russ, Detlef; Ebinger, Thomas; Illich, Wolfgang; Steiner, Rudolf W.

    2003-10-01

    We developed a new surgical procedure to improve the recurrence rate using an Er:YAG laser as dissection tool for the carpal ligament with the objective to ablate a small amount of the carpal ligament and to denaturate its ends. The Er:YAG Laser was transmitted to the applicator via a GeO fiber. With this system we proceeded 10 carpal ligament dissections without any complications in the follow-up period. All patients were free of pain and recurrence.

  12. Assessment of the Presence of Carpal Tunnel Syndrome in Patients with Diabetes Mellitus, Hypothyroidism and Acromegaly

    PubMed Central

    Nas, Kemal; Kilinç, Faruk; Tasdemir, Nebahat; Bozkurt, Mehtap; Yildiz, Ismail

    2015-01-01

    Introduction Carpal tunnel syndrome (CTS) is one of the most common entrapment neuropathies of the upper limbs. It results from compromised median nerve function of the wrist that is caused by increased pressure in the carpal tunnel. Repetitive use of the hand and wrist, obesity, pregnancy, rheumatoid diseases, trauma and endocrinopathies are some of the risk factors for CTS. Aim The purpose of this study was to find out whether patients with diabetes mellitus (DM), hypothyroidism and acromegaly have an increased incidence of carpal tunnel syndrome compared to each other and normal population. Materials and Methods Patients were assigned into three groups as follows: patients with type II DM n: 100, patients with hypothyroidism n:48 and patients with acromegaly n:36. In addition, 50 healthy individuals were included in the study as control subjects. Patients were asked if they had any pain, symptoms of paraesthesia and numbness. Patients with peripheral neuropathy were excluded from the study. Boston Symptom Severity Scale and Functional Capacity Scale were used to assess symptom severity and functional capacity. CTS was investigated by performing electrophysiological study for both hands. Results The incidence of CTS was significantly higher in all three groups compared to the control group (p>0.05). In addition, the incidence of CTS was significantly higher in the DM group compared to the hypothyroid and acromegaly groups (p<0.001). The incidence of bilateral CTS in the DM group was significantly higher compared to both hypothyroid and acromegaly groups and the control group (p<0.001). Conclusion CTS has a higher incidence in DM, hypothyroid and acromegaly patients compared to healthy individuals. Clinicians should be careful about development of CTS in DM, hypothyroidism and acromegaly. They should adopt a multidisciplinary approach and co-operate with the psychiatrist. PMID:26266148

  13. Infrared thermography based on artificial intelligence for carpal tunnel syndrome diagnosis.

    PubMed

    Jesensek Papez, B; Palfy, M; Turk, Z

    2008-01-01

    Thermography for the measurement of surface temperatures is well known in industry, although is not established in medicine despite its safety, lack of pain and invasiveness, easy reproducibility, and low running costs. Promising results have been achieved in nerve entrapment syndromes, although thermography has never represented a real alternative to electromyography. Here an attempt is described to improve the diagnosis of carpal tunnel syndrome with thermography using a computer-based system employing artificial neural networks to analyse the images. Method reliability was tested on 112 images (depicting the dorsal and palmar sides of 26 healthy and 30 pathological hands), with the hand divided into 12 segments and compared relative to a reference. Palmar segments appeared to have no beneficial influence on classification outcome, whereas dorsal segments gave improved outcome with classification success rates near to or over 80%, and finger segments influenced by the median nerve appeared to be of greatest importance. These are preliminary results from a limited number of images and further research will be undertaken as our image database grows.

  14. Efficacy of paraffin wax bath for carpal tunnel syndrome: a randomized comparative study

    NASA Astrophysics Data System (ADS)

    Ordahan, Banu; Karahan, Ali Yavuz

    2017-12-01

    Carpal tunnel syndrome (CTS) is the most frequently diagnosed neuropathy of upper extremity entrapment neuropathies. We aimed to investigate the effectiveness of paraffin therapy in patients with CTS. Seventy patients diagnosed with mild or moderate CTS were randomly divided into two groups as splint treatment (during the night and day time as much as possible for 3 weeks) alone and splint (during the night and day time as much as possible for 3 weeks) + paraffin treatment (five consecutive days a week for 3 weeks). Clinical and electrophysiological assessments were performed before and 3 weeks after treatment. The patients were assessed by using visual analog scale (VAS) for pain, electroneuromyography (ENMG), and Boston Carpal Tunnel Syndrome Questionnaire (BCTSQ). The significant improvement was found in VAS scores in both groups when compared with pretreatment values ( p < 0.05). There was no significant improvement in functional capacity score ( p > 0.05), whereas a significant improvement was noted in the BCTQ symptom severity scale score in the splint group ( p < 0.05). Significant improvements were demonstrated in both scorers in the combined treatment group. Similarly, significant improvements were found in the combined treatment group in terms of motor and sensory distal latency, sensory amplitude, and median sensory nerve velocity ( p < 0.05). There was no significant change in electrophysiologic parameters in the splint group ( p > 0.05), and the difference in these parameters between the groups was statistically significant ( p < 0.05). In conclusion, using splinting alone in patients with CTS is an effective treatment for reducing symptoms in the early stages. Paraffin treatment with splint increases the recovery in functional and electrophysiological parameters.

  15. Ergonomic positioning or equipment for treating carpal tunnel syndrome.

    PubMed

    O'Connor, Denise; Page, Matthew J; Marshall, Shawn C; Massy-Westropp, Nicola

    2012-01-18

    Non-surgical treatment, including ergonomic positioning or equipment, are sometimes offered to people experiencing mild to moderate symptoms from carpal tunnel syndrome (CTS). The effectiveness and duration of benefit from ergonomic positioning or equipment interventions for treating CTS are unknown. To assess the effects of ergonomic positioning or equipment compared with no treatment, a placebo or another non-surgical intervention in people with CTS. We searched the Cochrane Neuromuscular Disease Group Specialized Register (14 June 2011), the Cochrane Central Register of Controlled Trials (CENTRAL) (2011, Issue 2, in The Cochrane Library), MEDLINE (1966 to June 2011), EMBASE (1980 to June 2011), CINAHL Plus (1937 to June 2011), and AMED (1985 to June 2011). We also reviewed the reference lists of randomised or quasi-randomised trials identified from the electronic search. Randomised or quasi-randomised controlled trials comparing ergonomic positioning or equipment with no treatment, placebo or another non-surgical intervention in people with CTS. Two review authors independently selected trials for inclusion, extracted data and assessed risk of bias of included studies. We calculated risk ratios (RR) and mean differences (MD) with 95% confidence intervals (CI) for the primary and secondary outcomes. We pooled results of clinically and statistically homogeneous trials, where possible, to provide estimates of the effect of ergonomic positioning or equipment. We included two trials (105 participants) comparing ergonomic versus placebo keyboards. Neither trial assessed the primary outcome (short-term overall improvement) or adverse effects of interventions. In one small trial (25 participants) an ergonomic keyboard significantly reduced pain after 12 weeks (MD -2.40; 95% CI -4.45 to -0.35) but not six weeks (MD -0.20; 95% CI -1.51 to 1.11). In this same study, there was no difference between ergonomic and standard keyboards in hand function at six or 12 weeks or palm

  16. Spatial-temporal features of thermal images for Carpal Tunnel Syndrome detection

    NASA Astrophysics Data System (ADS)

    Estupinan Roldan, Kevin; Ortega Piedrahita, Marco A.; Benitez, Hernan D.

    2014-02-01

    Disorders associated with repeated trauma account for about 60% of all occupational illnesses, Carpal Tunnel Syndrome (CTS) being the most consulted today. Infrared Thermography (IT) has come to play an important role in the field of medicine. IT is non-invasive and detects diseases based on measuring temperature variations. IT represents a possible alternative to prevalent methods for diagnosis of CTS (i.e. nerve conduction studies and electromiography). This work presents a set of spatial-temporal features extracted from thermal images taken in healthy and ill patients. Support Vector Machine (SVM) classifiers test this feature space with Leave One Out (LOO) validation error. The results of the proposed approach show linear separability and lower validation errors when compared to features used in previous works that do not account for temperature spatial variability.

  17. Comparison of two ways of altering carpal tunnel pressure with ultrasound surface wave elastography.

    PubMed

    Cheng, Yu-Shiuan; Zhou, Boran; Kubo, Kazutoshi; An, Kai-Nan; Moran, Steven L; Amadio, Peter C; Zhang, Xiaoming; Zhao, Chunfeng

    2018-06-06

    Higher carpal tunnel pressure is related to the development of carpal tunnel syndrome. Currently, the measurement of carpal tunnel pressure is invasive and therefore, a noninvasive technique is needed. We previously demonstrated that speed of wave propagation through a tendon in the carpal tunnel measured by ultrasound elastography could be used as an indicator of carpal tunnel pressure in a cadaveric model, in which a balloon had to be inserted into the carpal tunnel to adjust the carpal tunnel pressure. However, the method for adjusting the carpal tunnel pressure in the cadaveric model is not applicable for the in vivo model. The objective of this study was to utilize a different technique to adjust carpal tunnel pressure via pressing the palm and to validate it with ultrasound surface wave elastography in a human cadaveric model. The outcome was also compared with a previous balloon insertion technique. Results showed that wave speed of intra-carpal tunnel tendon and the ratio of wave speed of intra-and outer-carpal tunnel tendons increased linearly with carpal tunnel pressure. Moreover, wave speed of intra carpal tunnel tendon via both ways of altering carpal tunnel pressure showed similar results with high correlation. Therefore, it was concluded that the technique of pressing the palm can be used to adjust carpal tunnel pressure, and pressure changes can be detected via ultrasound surface wave elastography in an ex vivo model. Future studies will utilize this technique in vivo to validate the usefulness of ultrasound surface wave elastography for measuring carpal tunnel pressure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The effect of polarized polychromatic noncoherent light (bioptron) therapy on patients with carpal tunnel syndrome.

    PubMed

    Raeissadat, Seyed Ahmad; Rayegani, Seyed Mansoor; Rezaei, Sajad; Sedighipour, Leyla; Bahrami, Mohammad Hasan; Eliaspour, Dariush; Karimzadeh, Afshin

    2014-01-01

    To study the effects of Polarized Polychromatic Noncoherent Light (Bioptron) therapy on patients with carpal tunnel syndrome (CTS). This study was designed as a randomized clinical trial. Forty four patients with mild or moderate CTS (confirmed by clinical and electrodiagnostic studies) were assigned randomly into two groups (intervention and control goups). At the beginning of the study, both groups received wrist splinting for 8 weeks. Bioptron light was applied for the intervention group (eight sessions, for 3/weeks). Bioptron was applied perpendicularly to the wrist from a 10 centimeter sdistance. Pain severity and electrodiagnostic measurements were compared from before to 8 weeks after initiating each treatment. Eight weeks after starting the treatments, the mean of pain severity based on Visual Analogue Scale (VAS) scores decreased significantly in both groups. Median Sensory Nerve Action Potential (SNAP) latency decreased significantly in both groups. However, other electrophysiological findings (median Compound Motor Action Potential (CMAP) latency and amplitude, also SNAP amplitude) did not change after the therapy in both groups. There was no meaningful difference between two groups regarding the changes in the pain severity. Bioptron with the above mentioned parameters led to therapeutic effects equal to splinting alone in patients with carpal tunnel syndrome. However, applying Bioptron with different therapeutic protocols and light parameters other than used in this study, perhaps longer duration of therapy and long term assessment may reveal different results favoring Bioptron therapy.

  19. The Effect of Polarized Polychromatic Noncoherent Light (Bioptron) Therapy on Patients with Carpal Tunnel Syndrome

    PubMed Central

    Raeissadat, Seyed Ahmad; Rayegani, Seyed Mansoor; Rezaei, Sajad; Bahrami, Mohammad Hasan; Eliaspour, Dariush; Karimzadeh, Afshin

    2014-01-01

    Introduction: To study the effects of Polarized Polychromatic Noncoherent Light (Bioptron) therapy on patients with carpal tunnel syndrome (CTS). Methods: This study was designed as a randomized clinical trial. Forty four patients with mild or moderate CTS (confirmed by clinical and electrodiagnostic studies) were assigned randomly into two groups (intervention and control goups). At the beginning of the study, both groups received wrist splinting for 8 weeks. Bioptron light was applied for the intervention group (eight sessions, for 3/weeks). Bioptron was applied perpendicularly to the wrist from a 10 centimeter sdistance. Pain severity and electrodiagnostic measurements were compared from before to 8 weeks after initiating each treatment. Results: Eight weeks after starting the treatments, the mean of pain severity based on Visual Analogue Scale (VAS) scores decreased significantly in both groups. Median Sensory Nerve Action Potential (SNAP) latency decreased significantly in both groups. However, other electrophysiological findings (median Compound Motor Action Potential (CMAP) latency and amplitude, also SNAP amplitude) did not change after the therapy in both groups. There was no meaningful difference between two groups regarding the changes in the pain severity. Conclusion: Bioptron with the above mentioned parameters led to therapeutic effects equal to splinting alone in patients with carpal tunnel syndrome. However, applying Bioptron with different therapeutic protocols and light parameters other than used in this study, perhaps longer duration of therapy and long term assessment may reveal different results favoring Bioptron therapy. PMID:25606338

  20. Hypothyroidism and carpal tunnel syndrome: a meta-analysis.

    PubMed

    Shiri, Rahman

    2014-12-01

    This study aimed to assess the magnitude of the association between hypothyroidism and carpal tunnel syndrome (CTS). Eighteen studies were included in a random-effects meta-analysis. A meta-analysis of the studies that did not control their estimates for any confounder showed an association between a thyroid disease (hypo- or hyperthyroidism) and CTS (N = 9,573, effect size [ES] = 1.32 (95% confidence interval [CI], 1.04-1.68) and between hypothyroidism and CTS (N = 64,531, ES = 2.15 [95% CI, 1.64-2.83]). When a meta-analysis limited to the studies that controlled their estimates for some potential confounders, the association between a thyroid disease and CTS disappeared (N = 4,799, ES = 1.17 [95% CI, 0.71-1.92], I(2) = 0%), and the effect size for hypothyroidism largely attenuated (N = 71,133, ES = 1.44 [95% CI, 1.27-1.63], I(2) = 0%). Moreover, there was evidence of publication bias. This meta-analysis found only a modest association between hypothyroidism and CTS. Confounding and publication bias may still account for part of the remaining excess risk. © 2014 Wiley Periodicals, Inc.

  1. Translation and Validation of the Persian Version the Boston Carpal Tunnel Syndrome Questionnaire.

    PubMed

    Hassankhani, Golnaz Ghayyem; Moradi, Ali; Birjandinejad, Ali; Vahedi, Ehsan; Kachooei, Amir R; Ebrahimzadeh, Mohammad H

    2018-01-01

    Carpal tunnel syndrome (CTS) is recognized as the most common type of neuropathies. Questionnaires are the method of choice for evaluating patients with CTS. Boston Carpal Tunnel Syndrome (BCTS) is one of the most famous questionnaires that evaluate the functional and symptomatic aspects of CTS. This study was performed to evaluate the validity and reliability of the Persian version of BCTS questionnaire. First, both parts of the original questionnaire (Symptom Severity Scale and Functional Status Scale) were translated into Persian by two expert translators. The translated questionnaire was revised after merging and confirmed by an orthopedic hand surgeon. The confirmed questionnaire was interpreted back into the original language (English) to check for any possible content inequality between the original questionnaire and its final translated version. The final Persian questionnaire was answered by 10 patients suffering from CTS to elucidate its comprehensibility; afterwards, it was filled by 142 participants along with the Persian version of the Quick-DASH questionnaire. After 2 to 6 days, the translated questionnaire was refilled by some of the previous patients who had not received any substantial medical treatment during that period. Among all 142 patients, 13.4 % were male and 86.6 % were female. The reliability of the questionnaire was tested using Cronbach's alpha and Intraclass correlation coefficient (ICC). Cronbach's alpha was 0.859 for symptom severity scale (SSS) and 0.878 for functional status scale (FSS). Also, ICCs were calculated as 0.538 for SSS and 0.773 for FSS. In addition, construct validity of SSS and FSS against QuickDASH were 0.641 and 0.701, respectively. Based on our results, the Persian version of the BCTQ is valid and reliable. Level of evidence: II.

  2. Manual Physical Therapy Versus Surgery for Carpal Tunnel Syndrome: A Randomized Parallel-Group Trial.

    PubMed

    Fernández-de-Las Peñas, César; Ortega-Santiago, Ricardo; de la Llave-Rincón, Ana I; Martínez-Perez, Almudena; Fahandezh-Saddi Díaz, Homid; Martínez-Martín, Javier; Pareja, Juan A; Cuadrado-Pérez, Maria L

    2015-11-01

    This randomized clinical trial investigated the effectiveness of surgery compared with physical therapy consisting of manual therapies including desensitization maneuvers in carpal tunnel syndrome (CTS). The setting was a public hospital and 2 physical therapy practices in Madrid, Spain. One hundred twenty women with CTS were enrolled between February 2013 and January 2014, with 1-year follow-up completed in January 2015. Interventions consisted of 3 sessions of manual therapies including desensitization maneuvers of the central nervous system (physical therapy group, n = 60) or decompression/release of the carpal tunnel (surgical group, n = 60). The primary outcome was pain intensity (mean pain and the worst pain), and secondary outcomes included functional status and symptoms severity subscales of the Boston Carpal Tunnel Questionnaire and the self-perceived improvement. They were assessed at baseline and 1, 3, 6, and 12 months by a blinded assessor. Analysis was by intention to treat. At 12 months, 111 (92%) women completed the follow-up (55/60 physical therapy, 56/60 surgery). Adjusted analyses showed an advantage (all, P < .01) for physical therapy at 1 and 3 months in mean pain (Δ -2.0 [95% confidence interval (CI) -2.8 to -1.2]/-1.3 [95% CI -2.1 to -.6]), the worst pain (Δ -2.9 [-4.0 to -2.0]/-2.0 [-3.0 to -.9]), and function (Δ -.8 [-1.0 to -.6]/-.3 [-.5 to -.1]), respectively. Changes in pain and function were similar between the groups at 6 and 12 months. The 2 groups had similar improvements in the symptoms severity subscale of the Boston Carpal Tunnel Questionnaire at all follow-ups. In women with CTS, physical therapy may result in similar outcomes on pain and function to surgery. http://www.clinicaltrials.gov, ClinicalTrials.gov, NCT01789645. This study found that surgery and physical manual therapies including desensitization maneuvers of the central nervous system were similarly effective at medium-term and long-term follow-ups for improving pain

  3. Prevalence of Obesity in Carpal Tunnel Syndrome Patients: A Cross-Sectional Survey.

    PubMed

    Mansoor, Salman; Siddiqui, Maimoona; Mateen, Farrukh; Saadat, Shoab; Khan, Zarak H; Zahid, Mehr; Khan, Hamza H; Malik, Shuja A; Assad, Salman

    2017-07-26

    Carpal tunnel syndrome (CTS) is the most common compressive entrapment neuropathy caused by the compression of the median nerve at the wrist space known as the carpal tunnel. The epidemiologic factors related to CTS include genetic, medical, social, vocational, and demographic factors. The common symptoms experienced include pain, paresthesia, and numbness in the median nerve distribution. If left untreated, it can lead to irreversible median nerve damage, causing a loss of hand function. Body mass index (BMI) has been attributed as a risk factor for the development of CTS. We planned to determine the frequency of obesity among CTS patients in the neurophysiology department of a tertiary care center in Islamabad, Pakistan. The survey was designed as a cross-sectional descriptive study from March 2016 to August 2016 using a consecutive nonprobability sampling technique. A total of 112 patients with a mean age of 54 ± 5 years were included in the study. In the study population, 39 patients (35 percent) were males and 73 were females (65 percent). Based on BMI, 74 patients (66 percent) had a normal weight and 38 (34 percent) were obese. The frequency of obesity in our study was 34 percent, excluding the other comorbid conditions, which is quite high. Targeted therapy in those with CTS should also include weight reduction measures because obesity poses a cause-and-effect relationship for both the severity and the pathogenesis of CTS.

  4. Blood Flow Changes in Subsynovial Connective Tissue on Contrast-Enhanced Ultrasonography in Patients With Carpal Tunnel Syndrome Before and After Surgical Decompression.

    PubMed

    Motomiya, Makoto; Funakoshi, Tadanao; Ishizaka, Kinya; Nishida, Mutsumi; Matsui, Yuichiro; Iwasaki, Norimasa

    2017-11-24

    Although qualitative alteration of the subsynovial connective tissue in the carpal tunnel is considered to be one of the most important factors in the pathophysiologic mechanisms of carpal tunnel syndrome (CTS), little information is available about the microcirculation in the subsynovial connective tissue in patients with CTS. The aims of this study were to use contrast-enhanced ultrasonography (US) to evaluate blood flow in the subsynovial connective tissue proximal to the carpal tunnel in patients with CTS before and after carpal tunnel release. The study included 15 volunteers and 12 patients with CTS. The blood flow in the subsynovial connective tissue and the median nerve was evaluated preoperatively and at 1, 2, and 3 months postoperatively using contrast-enhanced US. The blood flow in the subsynovial connective tissue was higher in the patients with CTS than in the volunteers. In the patients with CTS, there was a significant correlation between the blood flow in the subsynovial connective tissue and the median nerve (P = .01). The blood flow in both the subsynovial connective tissue and the median nerve increased markedly after carpal tunnel release. Our results suggest that increased blood flow in the subsynovial connective tissue may play a role in the alteration of the microcirculation within the median nerve related to the pathophysiologic mechanisms of CTS. The increase in the blood flow in the subsynovial connective tissue during the early postoperative period may contribute to the changes in intraneural circulation, and these changes may lead to neural recovery. © 2017 by the American Institute of Ultrasound in Medicine.

  5. The role of ultrasound in the diagnosis and management of carpal tunnel syndrome: a new paradigm.

    PubMed

    McDonagh, Cara; Alexander, Michael; Kane, David

    2015-01-01

    Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy, affecting 9% of women, and it is responsible for significant morbidity and occupational absence. Clinical assessment is used for initial diagnosis and nerve conduction (NC) studies are currently the principal test used to confirm the diagnosis. Sensitivity of NC studies is >85% and specificity is >95%. There is now good evidence that US can be used as an alternative to NC studies to diagnose CTS. US can assess the anatomy of the median nerve and also identify pathology of the surrounding structures that may compress the nerve. Median nerve enlargement (cross-sectional area ≥10 mm(2) at the level of the pisiform bone or tunnel inlet) is the most commonly used parameter to diagnose CTS on US, and sensitivity has been reported to be as high as 97.9% using this parameter. US may also be used to guide therapeutic corticosteroid injection into the carpal tunnel--thus avoiding median nerve injury--and to objectively monitor the response to treatment. There is now sufficient evidence to propose a new paradigm for the diagnosis of CTS that incorporates US. US is proposed as the initial diagnostic test in CTS based on similar sensitivity and specificity to NC studies but higher patient acceptability, lower cost and additional capability to assess carpal tunnel anatomy and guide injection. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Comparison of carpal tunnel injection techniques: a cadaver study.

    PubMed

    Ozturk, Kahraman; Esenyel, Cem Zeki; Sonmez, Mesut; Esenyel, Meltem; Kahraman, Sinan; Senel, Berna

    2008-01-01

    The purpose of the study was to evaluate the accuracy of injections into the carpal tunnel using three different portals in cadavers, and to define safe guidelines. In this study, 150 wrists of 75 cadavers (54 male, 21 female) were included. To compare three injection sites, 50 wrists of 25 cadavers were used for each technique; we used 23 gauge needles, and acrylic dye. The first injection technique: the needle was inserted 1cm proximal to the wrist crease and directed distally by roughly 45 in an ulnar direction through the flexor carpi radialis tendon. The second injection technique: the needle was inserted into the carpal tunnel from a point just ulnar to the palmaris longus tendon and 1cm proximal to the wrist crease. The third injection technique: the needle was inserted just distal to the distal skin crease of the wrist in line with the fourth ray. The first injection technique gave the highest accuracy rate, and this was also the safest injection site. Median nerve injuries caused by injection was seen mostly with the second technique. Although a steroid injection may provide symptomatic relief in patients with carpal tunnel syndrome, the median nerve and other structures in the carpal tunnel are at risk of injury. Because of that, the injection should be given using the correct technique by physicians skilled in carpal tunnel surgery.

  7. The Effects of Oscillatory Biofield Therapy on Pain and Functional Limitations Associated with Carpal Tunnel Syndrome: Randomized, Placebo-Controlled, Double-Blind Study.

    PubMed

    Nourbakhsh, Mohammad Reza; Bell, Thomas J; Martin, Jason Benson; Arab, Amir Massoud

    2016-11-01

    Biofield treatments have been used for pain control in patients with cancer and chronic pain. However, research on the effect of biofield treatment on specific somatic disorders is lacking. This study intends to investigate the effect of oscillating biofield therapy (OBFT) on symptoms of carpal tunnel syndrome. Randomized, placebo-controlled, double-blind study. Thirty patients with chronic carpal tunnel syndrome participated in the study. Patients were randomly assigned to active or placebo treatment groups. Those in the treatment group received six sessions of OBFT with intention to treat during a period of 2 weeks. Patients in the placebo group had the same number of treatment sessions with mock OBFT treatment. The Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire; Symptom Severity Scale (SSS); and Functional Status Scale (FSS) were used for outcome assessment. Both clinically and statistically significant changes in intensity of pain with activity (95% confidence interval [CI], 2.5-4.2; p = 0.000), night pain (p = 0.000, 95% CI, 3.2-5.7), DASH questionnaire (95% CI, 12.0-21.9; p = 0.000), SSS (95% CI, 0.64-1.15; p = 0.003), and FSS (95% CI, 0.41-0.97; p = 0.029) were found between the treatment and placebo groups. Statistically significant reduction in number of patients with positive results on the Phalen test (87%; p = 0.000), Tinel sign (73%; p = 0.000), and hand paresthesia (80%; p = 0.000) was noted in the treatment group. During 6-month follow-up, 86% of patients in the treatment group remained pain free and had no functional limitations. OBFT can be a viable and effective treatment for improving symptoms and functional limitations associated with chronic carpal tunnel syndrome.

  8. The Effects of Oscillatory Biofield Therapy on Pain and Functional Limitations Associated with Carpal Tunnel Syndrome: Randomized, Placebo-Controlled, Double-Blind Study

    PubMed Central

    Bell, Thomas J.; Martin, Jason Benson; Arab, Amir Massoud

    2016-01-01

    Abstract Objectives: Biofield treatments have been used for pain control in patients with cancer and chronic pain. However, research on the effect of biofield treatment on specific somatic disorders is lacking. This study intends to investigate the effect of oscillating biofield therapy (OBFT) on symptoms of carpal tunnel syndrome. Design: Randomized, placebo-controlled, double-blind study. Participants: Thirty patients with chronic carpal tunnel syndrome participated in the study. Intervention: Patients were randomly assigned to active or placebo treatment groups. Those in the treatment group received six sessions of OBFT with intention to treat during a period of 2 weeks. Patients in the placebo group had the same number of treatment sessions with mock OBFT treatment. Outcome measure: The Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire; Symptom Severity Scale (SSS); and Functional Status Scale (FSS) were used for outcome assessment. Results: Both clinically and statistically significant changes in intensity of pain with activity (95% confidence interval [CI], 2.5–4.2; p = 0.000), night pain (p = 0.000, 95% CI, 3.2–5.7), DASH questionnaire (95% CI, 12.0–21.9; p = 0.000), SSS (95% CI, 0.64–1.15; p = 0.003), and FSS (95% CI, 0.41–0.97; p = 0.029) were found between the treatment and placebo groups. Statistically significant reduction in number of patients with positive results on the Phalen test (87%; p = 0.000), Tinel sign (73%; p = 0.000), and hand paresthesia (80%; p = 0.000) was noted in the treatment group. During 6-month follow-up, 86% of patients in the treatment group remained pain free and had no functional limitations. Conclusion: OBFT can be a viable and effective treatment for improving symptoms and functional limitations associated with chronic carpal tunnel syndrome. PMID:27487406

  9. Prognostic factors for return-to-work following surgery for carpal tunnel syndrome: a systematic review.

    PubMed

    Peters, Susan; Johnston, Venerina; Hines, Sonia; Ross, Mark; Coppieters, Michel

    2016-09-01

    Carpal tunnel syndrome (CTS) is a common problem, that can be effectively managed by surgery. Screening for prognostic factors is important to identify workers who are at a greater risk of a poor work outcome in order to implement tailored interventions to facilitate their return-to-work. To synthesize the best available evidence on the association of preoperative prognostic factors with work-related outcomes in people who have undergone carpal tunnel surgery. Participants included those who were employed at the time of surgery, underwent carpal tunnel surgery and planned to return-to-work. The primary outcome was return-to-work. Quantitative studies investigating at least one prognostic factor for a work-related outcome in studies of workers who had carpal tunnel surgery were considered. Eleven electronic databases were searched from their respective inception date up to July 2015. A total of 3893 publications were reviewed. The quality of the included studies was assessed by two reviewers using a modified version of an appraisal tool (Joanna Briggs Institute Meta-analysis of Statistical Assessment and Review Instrument [JBI-MAStARI]). The following criteria were evaluated: study population representativeness, clearly defined prognostic factors and outcomes, potential confounding variables and appropriate statistical analysis. Data extraction was performed using a modified version of the standardized extraction tool from JBI-MAStARI. Statistical pooling was not possible. Findings are presented in tables and narrative format. Eleven studies (13 publications) investigating 93 prognostic factors for delayed return-to-work or prolonged work disability outcomes and 27 prognostic factors for work role functioning in 4187 participants were identified.Prognostic factors associated with workers' increased likelihood of an earlier return-to-work in a moderate-to-high-quality study included worker expected or desired fewer days off work, occupation, lower pain anxiety and if

  10. Effectiveness of PELOID therapy in carpal tunnel syndrome: A randomized controlled single blind study

    NASA Astrophysics Data System (ADS)

    Metin Ökmen, Burcu; Kasapoğlu Aksoy, Meliha; Güneş, Aygül; Eröksüz, Riza; Altan, Lale

    2017-08-01

    Carpal tunnel syndrome(CTS) is the most common neuromuscular cause of upper extremity disability. We aimed to investigate the effectiveness of peloid therapy in patients with CTS. This randomized, controlled, single-blind study enrolled 70 patients between the ages of 30 to 65 who had a diagnosis of either mild, mild-to-moderate, or moderate CTS. The patients were randomized into two groups using random number table. In the first group, (Group 1)( n = 35), patients were given splint (every night for 6 weeks) + peloid treatment(five consecutive days a week for 2 weeks) and in the second group, (Group 2)( n = 28), patients received splint treatment(every night for 6 weeks) alone. The patients were assessed by using visual analog scale(VAS) for pain, electroneuromyography(ENMG), the Boston Carpal Tunnel Syndrome Questionnaire(BCTSQ), hand grip strength(HGS), finger grip strength(FGS), and Short Form-12(SF-12). The data were obtained before treatment(W0), immediately after treatment(W2), and one month after treatment(W6). Both in Group 1 and 2, there was a statistically significant improvement in all the evaluation parameters at W2 and W6 when compared to W0( p < 0.05). Comparison of the groups with each other revealed significantly better results for VAS, BCTSQ, mSNCV, SF-12 in Group 1 than in Group 2 at W2( p < 0.05). There was also a statistically significant difference in favor of Group 1 for VAS, BCTSQ, FGS and MCS at W6 when compared to W0 ( p < 0.05). The results of our study demonstrated that in patients with CTS; peloid + splint treatment was more effective than splint treatment alone in pain, functionality and life quality both at after treatment(W2) and one month after treatment (W6). We may suggest peloid as a supplementary therapeutic agent in CTS.

  11. Cross-cultural adaptation of the Korean version of the Boston carpal tunnel questionnaire: its clinical evaluation in patients with carpal tunnel syndrome following local corticosteroid injection.

    PubMed

    Park, Dong-Jin; Kang, Ji-Hyoun; Lee, Jeong-Won; Lee, Kyung-Eun; Wen, Lihui; Kim, Tae-Jong; Park, Yong-Wook; Nam, Tai-Seung; Kim, Myung-Sun; Lee, Shin-Seok

    2013-07-01

    The aim of this study was to assess and validate the Korean version of the Boston Carpal Tunnel Questionnaire (K-BCTQ) in patients with carpal tunnel syndrome (CTS). After translation and cultural adaptation of the BCTQ to a Korean version, the K-BCTQ was administered to 54 patients with CTS; it was administered again after 2 weeks to assess reliability. Additionally, we administered K-DASH and EQ-5D to assess construct-validity. In a prospective study of responsiveness to clinical change, 29 of 54 patients were treated by ultrasonography-guided local corticosteroid injection therapy. The internal consistency of the K-BCTQ was high (Cronbach's alpha: 0.915) and the intra-class correlation coefficients were 0.931 for the symptom severity scale (P<0.001) and 0.844 for the functional severity scale (P<0.001). The construct-validity between the symptom severity scale and the K-DASH, and between the functional severity scale and the K-DASH were significantly correlated (both P<0.001). Clinical improvement was noted in 29 patients with injection therapy. The effect size of symptom severity was 0.67, and that of functional severity was 0.58. In conclusion, the K-BCTQ shows good reliability, construct-validity, and acceptable responsiveness after local corticosteroid injection therapy (Clinical trial number, KCT0000050).

  12. A program plan addressing carpal tunnel syndrome: the utility of King's goal attainment theory.

    PubMed

    Norgan, G H; Ettipio, A M; Lasome, C E

    1995-08-01

    1. Today's nurse is prepared to address the needs of groups of individuals who share common characteristics or risks (aggregates). Program planning skills and ability to use nursing theory can enhance the nurse's effectiveness in addressing the needs of such aggregates. 2. Carpal tunnel syndrome and other repetitive stress injuries are very costly to industry, both in terms of monetary loss and lost work hours. Such injuries can be reduced in the workplace through careful observation and communication of trends by the nurse. 3. The systems perspective of King's goal attainment theory guided the nurse in problem solving and facilitating the development of a workplace capable of responding to trends as they occur.

  13. Minimally invasive carpal tunnel decompression using the KnifeLight.

    PubMed

    Hwang, Peter Y K; Ho, Chi Long

    2007-02-01

    Carpal tunnel syndrome is a common condition causing hand pain, dysfunction, and paresthesia. Endoscopic carpal tunnel decompression offers many advantages compared with conventional open surgical decompression. However, it is equipment intensive and requires familiarity with endoscopic surgery. We review a minimally invasive technique to divide the flexor retinaculum by using a new instrument, the KnifeLight (Stryker, Kalamazoo, Michigan), which combines the advantages of the open and endoscopic methods, without the need for endoscopic set-up. Between July 2003 and April 2005, 44 consecutive patients (26 women [59%] and 18 men [36%]), with clinical signs and symptoms, as well as electrodiagnostic findings consistent with carpal tunnel syndrome, who did not respond to non-surgical treatment, underwent the new procedure. All patients were asked about scar hypertrophy, scar tenderness, and pillar pain. The Michigan Hand Outcomes Questionnaire (MHQ) was used to determine overall hand function, activities of daily living, work performance, pain, aesthetics, and satisfaction with hand function. Other preoperative testing included grip strength and lateral pinch strength. Grip strength was measured using the Jamar hand dynamometer (Asimov Engineering Co., Los Angeles, CA); lateral key pinch was measured using the Jamar hydraulic pinch gauge. Postoperative evaluations were scheduled at 2 weeks, 3 months, and 6 months after the procedure. A small 10-mm incision was made in the wrist crease and a small opening was made at the transverse carpal ligament. The KnifeLight tool was inserted, and the ligament was incised completely. Follow-up evaluations with use of quantitative measurements of grip strength, pinch strength, and hand dexterity were performed at 2 weeks, 3 months, and 6 months after surgery. Fifty procedures were performed on 22 left hands (44%) and 28 right hands (56%). There were no complications related to the approach. All patients were able to use their hands

  14. Kinesiotaping as an alternative treatment method for carpal tunnel syndrome.

    PubMed

    Geler Külcü, Duygu; Bursali, Canan; Aktaş, İlknur; Bozkurt Alp, Selin; Ünlü Özkan, Feyza; Akpinar, Pınar

    2016-06-23

    Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy. Conservative treatment choices are not always satisfactory. The aim of this study was to investigate the effect of kinesiotaping (KT) on pain level, grip strength, and functional status compared with that of placebo KT and orthotic device (OD) in patients with CTS. In this randomized, placebo-controlled study, participants were allocated into one of three groups: an experimental KT group (Group 1), a placebo KT group (Group 2), and an OD group (Group 3). Visual analogue scale (VAS) and Douleur Neuropathique 4 (DN4) scores, dynamometric grip strength measures, and the Boston CTS questionnaire (BQ) were the outcome measures. All groups significantly improved in terms of VAS scores (P < 0.05), DN4 scores (P < 0.05), and BQ scores (P < 0.05). Grip strength improved in Group 3 (P = 0.001). There was a significant difference among the groups with respect to BQ scores (P < 0.05). KT application for the treatment of CTS should be an alternative treatment choice.

  15. Prevalence of carpal fracture in Singapore.

    PubMed

    Hey, Hwee Weng Dennis; Dennis, Hey Hwee Weng; Chong, Alphonsus Khin Sze; Sze, Alphonsus Chong Khin; Murphy, Diarmuid

    2011-02-01

    To determine the prevalence of carpal fracture in Singapore, to compare demographic differences between isolated scaphoid and other carpal fractures, and to identify parameters associated with multiple carpal fractures. A total of 149 patients with 162 carpal fractures seen at the National University Hospital in 2009 were enrolled into the study. We retrospectively reviewed their case records and radiographic studies. Pertinent demographic data including patient age, gender, occupation, injured wrist, dominant hand, mechanism of injury, and type of carpal fracture were then recorded and statistically analyzed. We also performed a separate analysis of isolated scaphoid versus other carpal fractures and single versus multiple carpal fractures. Patients with carpal fracture were predominantly male (132), below 40 years of age (116), and usually right hand dominant (136). The more common occupations were students (30), full-time military national servicemen (24), and construction workers (14). Most presented after a fall on an outstretched hand from standing height (81). The scaphoid was the most common single carpal fracture (99). This was followed by triquetrum (27), hamate (5), pisiform (4), lunate (2), capitate (1), and trapezium (1). No fracture of the trapezoid was encountered. Ten patients had multiple carpal fractures, of which 4 were perilunate fracture dislocations. The mean age and male/female ratio for isolated scaphoid and other carpal fractures was 26 years versus 41 years (p<.001) and 13:1 versus 4:1 (p=.036), respectively. A high-energy mechanism of injury was the only parameter associated with multiple carpal fractures (p=.009). The prevalence of carpal fracture in our population was consistent with studies performed in other countries. Military conscription was identified as an at-risk activity predisposing to carpal fracture. Isolated scaphoid and other carpal fractures exhibit different demographics in terms of age and gender, which may be related

  16. Quantitative Muscle Ultrasonography in Carpal Tunnel Syndrome.

    PubMed

    Lee, Hyewon; Jee, Sungju; Park, Soo Ho; Ahn, Seung-Chan; Im, Juneho; Sohn, Min Kyun

    2016-12-01

    To assess the reliability of quantitative muscle ultrasonography (US) in healthy subjects and to evaluate the correlation between quantitative muscle US findings and electrodiagnostic study results in patients with carpal tunnel syndrome (CTS). The clinical significance of quantitative muscle US in CTS was also assessed. Twenty patients with CTS and 20 age-matched healthy volunteers were recruited. All control and CTS subjects underwent a bilateral median and ulnar nerve conduction study (NCS) and quantitative muscle US. Transverse US images of the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) were obtained to measure muscle cross-sectional area (CSA), thickness, and echo intensity (EI). EI was determined using computer-assisted, grayscale analysis. Inter-rater and intra-rater reliability for quantitative muscle US in control subjects, and differences in muscle thickness, CSA, and EI between the CTS patient and control groups were analyzed. Relationships between quantitative US parameters and electrodiagnostic study results were evaluated. Quantitative muscle US had high inter-rater and intra-rater reliability in the control group. Muscle thickness and CSA were significantly decreased, and EI was significantly increased in the APB of the CTS group (all p<0.05). EI demonstrated a significant positive correlation with latency of the median motor and sensory NCS in CTS patients (p<0.05). These findings suggest that quantitative muscle US parameters may be useful for detecting muscle changes in CTS. Further study involving patients with other neuromuscular diseases is needed to evaluate peripheral muscle change using quantitative muscle US.

  17. The Korean version of the Carpal Tunnel Questionnaire. Cross cultural adaptation, reliability, validity and responsiveness.

    PubMed

    Kim, J K; Lim, H M

    2015-02-01

    The purpose of this study was to translate and culturally adapt the Carpal Tunnel Questionnaire to produce an equivalent Korean version. A total of 53 patients completed the Korean version of the Carpal Tunnel Questionnaire pre-operatively and 3 months after open carpal tunnel release. All 53 also completed the Korean version of the Disabilities of Arm, Shoulder, and Hand questionnaire pre-operatively and 3 months post-operatively. Reliability was measured by determining the test-retest reliability and internal consistency. Test-retest reliability was assessed using intraclass correlation coefficients and paired t-tests, and internal consistency using Cronbach's alpha coefficients. Pearson correlation analysis was carried out on the Korean version of the Carpal Tunnel Questionnaire scores and the Korean version of the Disabilities of Arm, Shoulder, and Hand scores to assess construct validity. Responsiveness was evaluated using effect sizes and standardized response means. The reliability of the Korean version of the Carpal Tunnel Questionnaire was good. The scores in the Korean version of the Disabilities of Arm, Shoulder, and Hand strongly correlated with the scores in the Korean version of the Carpal Tunnel Questionnaire. Standardized response mean and effect size were both large for the Korean version of the Carpal Tunnel Questionnaire. The study shows that the Korean version of the Carpal Tunnel Questionnaire is a reliable, valid and responsive instrument for measuring outcomes in carpal tunnel syndrome. © The Author(s) 2014.

  18. Estimation of health-related-quality of life depends on which utility measure is selected for patients with carpal tunnel syndrome.

    PubMed

    Nazari, Goris; MacDermid, Joy C; Bain, James; Levis, Carolyn M; Thoma, Achilleas

    Cross-sectional. Carpal tunnel syndrome (CTS) refers to the compression neuropathy of the median nerve at the wrist. To establish the interinstrument reliability, convergent construct validity, and the levels of agreement of health utility indexes 2 and 3 (HUI-2 and HUI-3), EuroQol 5-dimensions (EQ-5D), EuroQol-visual analog scale (EQ-VAS) and to determine the difference of these utility measures based on age and gender in patients with carpal tunnel syndrome. Seventy-four patients with a confirmed diagnosis of carpal tunnel syndrome completed the 3 questionnaires and EQ-VAS a month before surgery. Demographic characteristics were reported. Intraclass correlation coefficients were used to assess relative interinstrument reliability. Pearson correlation coefficients (r) were used to establish convergent construct validity. Bland-Altman plots and t tests were used to describe the levels of agreement between the 4 utility measures. A 2-way analysis of variance was performed to determine the effect of age and gender on the utility measures; HUI-2, HUI-3, and EQ-5D. The intraclass correlation coefficients were 0.85 for HUI-3 vs HUI-2 and 0.80 for HUI-2 vs EQ-VAS. Pearson correlation coefficients ranged from 0.60 to 0.89; HUI-3 vs HUI-2: 0.89, and HUI-3 vs EQ-5D: 0.60. One-sample t test demonstrated significant differences between HUI-3 vs HUI-2, HUI-3 vs EQ-5D, and HUI-3 vs EQ-VAS measures, with mean differences of -0.12, -0.15, and -0.14, respectively. A 2-way analysis of variance test controlling for age and gender indicated neither as predictors of outcome scores. The HUI-3 vs HUI-2 and HUI-2 vs EQ-VAS demonstrated excellent interinstrument relative reliability measures. The HUI-3 vs HUI-2 displayed very strong convergent construct validity measures, and strong validity measures were established between the remaining utility measures. In addition, the pair-wise utility comparisons demonstrated minimal bias between HUI-2 vs EQ-5D, HUI-2 vs EQ-VAS, and EQ-VAS vs EQ

  19. Prevalence of clinical findings of carpal tunnel syndrome in Isfahanian dentists

    PubMed Central

    Haghighat, Abbas; Khosrawi, Saeid; Kelishadi, Abdolmajid; Sajadieh, Sepideh; Badrian, Hamid

    2012-01-01

    Background: Carpal tunnel Syndrome (CTS) is the most common compression neuropathy. Jobs with frequent and repetitive hand movements are one of the risk factors for this syndrome. The aim of this study was to determine the prevalence of CTS in Isfahanian dentists. Materials and Methods: In this cross-sectional descriptive study, 240 dentists were evaluated for CTS. Diagnosis was made according to both questionnaire and clinical tests of Phalen and Tinel. Age, sex, years of experience, working hours per week and the type of procedure were considered as dependent variables. All data were analyzed by Chi-square and T-test using SPSS software 11.5 (α=0.05). Results: Among the dentists who were studied, 173 (72%) were male and 67 (28%) were female. 16.2% of males and 17.9% of females had symptoms of CTS and there wasn’t any significant difference between them (P>0.05%). the prevalence increased with advancing age. In a way that it reached to 22.2% in ages more than 55 in contrast to 6% among individuals between 25–34 years old. With increasing of experience to 15 years the risk of CTS increased but an unexpected reduction was observed with more than 15 years of experience. Conclusion: This study showed the prevalence of CTS was 16.7% among dentists and was more common in older dentists. CTS prevalence was increased with age. The dentist population with more working hours per week and more experience years were more susceptible for this syndrome. Using suitable gloves, wrist splints and short periods of resting during vigorous continuous working can decrease the symptoms of this disease. PMID:23210072

  20. Efficacy of Manual Therapy Including Neurodynamic Techniques for the Treatment of Carpal Tunnel Syndrome: A Randomized Controlled Trial.

    PubMed

    Wolny, Tomasz; Saulicz, Edward; Linek, Paweł; Shacklock, Michael; Myśliwiec, Andrzej

    2017-05-01

    The purpose of this randomized trial was to compare the efficacy of manual therapy, including the use of neurodynamic techniques, with electrophysical modalities on patients with mild and moderate carpal tunnel syndrome (CTS). The study included 140 CTS patients who were randomly assigned to the manual therapy (MT) group, which included the use of neurodynamic techniques, functional massage, and carpal bone mobilizations techniques, or to the electrophysical modalities (EM) group, which included laser and ultrasound therapy. Nerve conduction, pain severity, symptom severity, and functional status measured by the Boston Carpal Tunnel Questionnaire were assessed before and after treatment. Therapy was conducted twice weekly and both groups received 20 therapy sessions. A baseline assessment revealed group differences in sensory conduction of the median nerve (P < .01) but not in motor conduction (P = .82). Four weeks after the last treatment procedure, nerve conduction was examined again. In the MT group, median nerve sensory conduction velocity increased by 34% and motor conduction velocity by 6% (in both cases, P < .01). There was no change in median nerve sensory and motor conduction velocities in the EM. Distal motor latency was decreased (P < .01) in both groups. A baseline assessment revealed no group differences in pain severity, symptom severity, or functional status. Immediately after therapy, analysis of variance revealed group differences in pain severity (P < .01), with a reduction in pain in both groups (MT: 290%, P < .01; EM: 47%, P < .01). There were group differences in symptom severity (P < .01) and function (P < .01) on the Boston Carpal Tunnel Questionnaire. Both groups had an improvement in functional status (MT: 47%, P < .01; EM: 9%, P < .01) and a reduction in subjective CTS symptoms (MT: 67%, P < .01; EM: 15%, P < .01). Both therapies had a positive effect on nerve conduction, pain reduction, functional status, and subjective symptoms in

  1. Carpal Tunnel Syndrome: Symptoms, Causes and Treatment Options. Literature Reviev.

    PubMed

    Zamborsky, Radoslav; Kokavec, Milan; Simko, Lukas; Bohac, Martin

    2017-01-26

    Carpal Tunnel Syndrome (CTS) is the most common form of entrapment neuropathy. Several authors have investigated the anatomical and pathophysiological features of CTS and have identified several parameters that, in combination, play a significant role in its pathophysiology. Advancement in biological research on CTS has enabled the advent of efficient diagnostic techniques such as provocative tests and nerve conduction studies. Sophisticated technologies, such as magnetic resonance imaging (MRI) and ultrasonography (US), have facilitated the diagnosis of CTS. This review article aims at consolidating the relevant medical literature pertaining to the symptoms, pathophysiology, clinical diagnosis and treatment strategies of CTS. It also compares the various methods of diagnosis and discusses their benefits and disadvantages. Finally, it sheds light on the conservative vs. surgical approach to treatment and compares them. While the surgical approach has proved to be more efficient relative to the conservative methods of steroid injections and splinting, many studies have demonstrated both advantages and adverse effects of the surgical methods. Surgical options and complications are discussed in detail. This article comprehensively summarizes all medical aspects of CTS to update medical professionals' knowledge regarding the disease.

  2. Physical Examination Has a Low Yield in Screening for Carpal Tunnel Syndrome

    PubMed Central

    Dale, Ann Marie; Descatha, Alexis; Coomes, Justin; Franzblau, Alfred; Evanoff, Bradley

    2013-01-01

    Background Physical examination is often used to screen workers for carpal tunnel syndrome (CTS). In a population of newly-hired workers, we evaluated the yield of such screening. Methods Our study population included 1108 newly-hired workers in diverse industries. Baseline data included a symptom questionnaire, physical exam, and bilateral nerve conduction testing of the median and ulnar nerves; individual results were not shared with the employer. We tested three outcomes: symptoms of CTS, abnormal median nerve conduction, and a case definition of CTS that required both symptoms and median neuropathy. Results Of the exam measures used, only Semmes-Weinstein sensory testing had a sensitivity value above 31%. Positive predictive values were low, and likelihood ratios were all under 5.0 for positive testing and over 0.2 for negative testing. Conclusion Physical examination maneuvers have a low yield for the diagnosis of CTS in workplace surveillance programs and in post-offer, pre-placement screening programs. PMID:21154516

  3. Frequency of Radiculopathy in Patients With Carpal Tunnel Syndrome and Paracervical Pain.

    PubMed

    Garcia-Santibanez, Rocio; Scelsa, Stephen N

    2016-06-01

    Patients with carpal tunnel syndrome (CTS) and paracervical pain (PCP) are often incorrectly diagnosed with cervical radiculopathy. The objective of the study is to determine how frequently such patients have electrophysiologic evidence of radiculopathy. We reviewed charts of patients with clinical features of CTS and at least 1 median nerve conduction parameter showing slowing across the wrist. Patients were divided into those with and without PCP. Radiculopathy was defined electrophysiologically. We assessed group differences in the frequency of radiculopathy and how radiculopathy frequency varied with median nerve entrapment severity. Of 108 patients meeting criteria, 56 had PCP and 52 did not. Eight of 56 patients with PCP and 4 of 52 without pain had cervical radiculopathy (P = 0.36). There was no difference in the frequency of radiculopathy related to the severity of median nerve entrapment (P = 0.64). In patients with CTS, PCP is not associated with cervical radiculopathy. Cervical radiculopathy is not more frequent in more severe CTS.

  4. Association Between Cardiovascular Risk Factors and Carpal Tunnel Syndrome in Pooled Occupational Cohorts.

    PubMed

    Hegmann, Kurt T; Thiese, Matthew Steven; Kapellusch, Jay; Merryweather, Andrew S; Bao, Stephen; Silverstein, Barbara; Wood, Eric M; Kendall, Richard; Wertsch, Jacqueline; Foster, James; Garg, Arun; Drury, David L

    2016-01-01

    The aim of the study was to ascertain if cardiovascular (CVD) risk factors are carpal tunnel syndrome (CTS) risk factors. Analysis of pooled baseline data from two large prospective cohort studies (n = 1824) assessed the relationships between a modified Framingham Heart Study CVD risk score both CTS and abnormal nerve conduction study prevalence. Quantified job exposures, personal and psychosocial confounders were statistically controlled. Odds ratio and 95% confidence intervals were calculated for individual risk scores. There was a strong relationship between CVD risk score and both CTS and abnormal nerve conduction study after adjustment for confounders, with odds ratios as high as 4.16 and 7.35, respectively. Dose responses were also observed. In this workplace population, there is a strong association between CVD risk scores and both CTS and abnormal nerve conduction study that persisted after controlling for confounders. These data suggest a potentially modifiable disease mechanism.

  5. Carbon film coating of abutment surfaces: effect on the abutment screw removal torque.

    PubMed

    Corazza, Pedro Henrique; de Moura Silva, Alecsandro; Cavalcanti Queiroz, José Renato; Salazar Marocho, Susana María; Bottino, Marco Antonia; Massi, Marcos; de Assunção e Souza, Rodrigo Othávio

    2014-08-01

    To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC). Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (α = 0.05). RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 μm uniformly coating the hexagonal abutment. DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.

  6. Importance of Recognizing Carpal Tunnel Syndrome for Neurosurgeons: A Review

    PubMed Central

    YUNOKI, Masatoshi; KANDA, Takahiro; SUZUKI, Kenta; UNEDA, Atsuhito; HIRASHITA, Koji; YOSHINO, Kimihiro

    2017-01-01

    Idiopathic carpal tunnel syndrome (CTS) is a common complaint, reflecting entrapment neuropathy of the upper extremity. CTS produces symptoms similar to those of other conditions, such as cervical spondylosis or ischemic or neoplastic intracranial disease. Because of these overlaps, patients with CTS are often referred to a neurosurgeon. Surgical treatment of CTS was started recently in our department. Through this experience, we realized that neurosurgeons should have an increased awareness of this condition so they can knowledgeably assess patients with a differential diagnosis that includes CTS and cervical spinal and cerebral disease. We conducted a literature review to gain the information needed to summarize current knowledge on the clinical, pathogenetic, and therapeutic aspects of CTS. Because the optimal diagnostic criteria for this disease are still undetermined, its diagnosis is based on the patient’s history and physical examination, which should be confirmed by nerve conduction studies and imaging modalities such as magnetic resonance imaging and ultrasonography. Treatment methods include observation, medication, splinting, steroid injections, and surgical intervention. Understanding the clinical features and pathogenesis of CTS, as well as the therapeutic options available to treat it, is important for neurosurgeons if they are to provide the correct management of patients with this disease. PMID:28154344

  7. Importance of Recognizing Carpal Tunnel Syndrome for Neurosurgeons: A Review.

    PubMed

    Yunoki, Masatoshi; Kanda, Takahiro; Suzuki, Kenta; Uneda, Atsuhito; Hirashita, Koji; Yoshino, Kimihiro

    2017-04-15

    Idiopathic carpal tunnel syndrome (CTS) is a common complaint, reflecting entrapment neuropathy of the upper extremity. CTS produces symptoms similar to those of other conditions, such as cervical spondylosis or ischemic or neoplastic intracranial disease. Because of these overlaps, patients with CTS are often referred to a neurosurgeon. Surgical treatment of CTS was started recently in our department. Through this experience, we realized that neurosurgeons should have an increased awareness of this condition so they can knowledgeably assess patients with a differential diagnosis that includes CTS and cervical spinal and cerebral disease. We conducted a literature review to gain the information needed to summarize current knowledge on the clinical, pathogenetic, and therapeutic aspects of CTS. Because the optimal diagnostic criteria for this disease are still undetermined, its diagnosis is based on the patient's history and physical examination, which should be confirmed by nerve conduction studies and imaging modalities such as magnetic resonance imaging and ultrasonography. Treatment methods include observation, medication, splinting, steroid injections, and surgical intervention. Understanding the clinical features and pathogenesis of CTS, as well as the therapeutic options available to treat it, is important for neurosurgeons if they are to provide the correct management of patients with this disease.

  8. Carpal Tunnel Syndrome in Behçet's Disease.

    PubMed

    Lee, Jungsoo; Cho, Suhyun; Kim, Do Young; Zheng, Zhenlong; Park, Hoon; Bang, Dongsik

    2015-07-01

    Behçet's disease (BD) is a chronic inflammatory disease characterized by orogenital ulcers, skin and ocular lesions, in addition to articular, vascular, and neurologic symptoms. Carpal tunnel syndrome (CTS), can also occur in BD patients secondary to inflammation in the connective tissues, vessels, and tendons, as well as nerve involvement in BD itself. However, reports of patients who have CTS in BD are rare. The aim of this study was to evaluate the clinical characteristics of CTS in BD patients. Retrospective analysis of the medical records of 1750 BD patients, and 14 (0.8%) BD patients who were diagnosed with CTS was performed at the BD Specialty Clinic of Severance Hospital. Patient demographics, disease activity/severity for both diseases, and the clinical characteristics of CTS in BD were recorded and analyzed. All 14 BD patients with CTS were women. Twelve patients (85.7%) were diagnosed with active BD. The CTS was mild in 8 patients (57.2%), moderate in 3 patients (21.4%), and severe in 3 patients (21.4%). Ten patients (71.4%) had BD prior to the diagnosis of CTS, and these 10 patients all had active BD. CTS can occur as a result of the inflammation associated with BD and can also be the presenting symptom of nerve involvement in BD. CTS can also develop as the initial symptom of BD. Therefore, a higher degree of suspicion should be maintained for CTS in patients with BD and vice versa; however, the exact relationship is uncertain.

  9. Association of psychological distress, quality of life and costs with carpal tunnel syndrome severity: a cross-sectional analysis of the PALMS cohort.

    PubMed

    Jerosch-Herold, Christina; Houghton, Julie; Blake, Julian; Shaikh, Anum; Wilson, Edward Cf; Shepstone, Lee

    2017-11-03

    The Prediciting factors for response to treatment in carpal tunnel syndrome (PALMS) study is designed to identify prognostic factors for outcome from corticosteroid injection and surgical decompression for carpal tunnel syndrome (CTS) and predictors of cost over 2 years. The aim of this paper is to explore the cross-sectional association of baseline patient-reported and clinical severity with anxiety, depression, health-related quality of life and costs of CTS in patients referred to secondary care. Prospective, multicentre cohort study initiated in 2013. We collected baseline data on patient-reported symptom severity (CTS-6), psychological status (Hospital Anxiety and Depression Scale), hand function (Michigan Hand Questionnaire) comorbidities, EQ-5D-3L (3-level version of EuroQol-5 dimension) and sociodemographic variables. Nerve conduction tests classified patients into five severity grades (mild to very severe). Data were analysed using a general linear model. 753 patients with CTS provided complete baseline data. Multivariable linear regression adjusting for age, sex, ethnicity, duration of CTS, smoking status, alcohol consumption, employment status, body mass index and comorbidities showed a highly statistically significant relationship between CTS-6 and anxiety, depression and the EQ-5D (p<0.0001 in each case). Likewise, a significant relationship was observed between electrodiagnostic severity and anxiety (p=0.027) but not with depression (p=0.986) or the EQ-5D (p=0.257). National Health Service (NHS) and societal costs in the 3 months prior to enrolment were significantly associated with self-reported severity (p<0.0001) but not with electrodiagnostic severity. Patient-reported symptom severity in CTS is significantly and positively associated with anxiety, depression, health-related quality of life, and NHS and societal costs even when adjusting for age, gender, body mass index, comorbidities, smoking, drinking and occupational status. In contrast, there

  10. Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?

    PubMed

    Siadat, Hakimeh; Pirmoazen, Salma; Beyabanaki, Elaheh; Alikhasi, Marzieh

    2015-07-01

    A significant vertical space that is corrected with vertical ridge augmentation may necessitate selection of longer abutments, which would lead to an increased vertical cantilever. This study investigated the influence of different abutment collar heights on single-unit dental implant screw-loosening after cyclic loading. Fifteen implant-abutment assemblies each consisted of an internal hexagonal implant were randomly assigned to 3 groups: Group1, consisting of 5 abutments with 1.5 mm gingival height (GH); Group2, 5 abutments with 3.5 mm GH; and Group3, 5 abutments with 5.5 mm GH. Each specimen was mounted in transparent auto-polymerizing acrylic resin block, and the abutment screw was tightened to 35 Ncm with an electric torque wrench. After 5 minutes, initial torque loss (ITL) was recorded for all specimens. Metal crowns were fabricated with 45° occlusal surface and were placed on the abutments. A cyclic load of 75 N and frequency of 1 Hz were applied perpendicular to the long axis of each specimen. After 500 000 cycles, secondary torque loss (STL) was recorded. One-way ANOVA analysis was used to evaluate the effects of abutment collar height before and after cyclic loading. One-way ANOVA showed that ITL among the groups was not significantly different (P = .52), while STL was significantly different among the groups (P = .008). Post-hoc Tukey HSD tests showed that STL values were significantly different between the abutments with 1.5 mm GH (Group1) and with 5.5 mm GH (Group3) (P = .007). A paired comparison t-test showed that cyclic loading significantly influenced the STL in comparison with the ITL in each group. Within the limitations of this study, it can be concluded that increase in height of the abutment collar could adversely affect the torque loss of the abutment screw.

  11. Clinical, electrophysiological and magnetic resonance imaging findings in carpal tunnel syndrome.

    PubMed

    Musluoğlu, L; Celik, M; Tabak, H; Forta, H

    2004-01-01

    To assess magnetic resonance imaging (MRI) findings in carpal tunnel syndrome (CTS) and to compare them with electrophysiological findings. Routine motor and sensory nerve conduction examinations and needle EMG were performed in 42 hands of 22 patients, who were clinically diagnosed as having CTS in at least one wrist. Of 29 wrists with clinically and electrophysiologically confirmed CTS, MRI could detect abnormality in 18 wrists (62%). Median nerve was found to be abnormal in MRI in 1 of 2 wrists with suspected clinical symptoms and proven CTS by electrophysiological examination. MRI was abnormal in 1 of 4 wrists with normal clinical and electrophysiological examination. MRI was abnormal in 46, 7% of wrists with mild CTS, in 61.6% of moderate CTS and in 100% of severe CTS. Volar bulging of the flexor retinaculum was detected in a single wrist with severe CTS. Enlargement of median nerve was observed in 3 of 5 severe CTS. MRI could be useful in the diagnosis of unproven cases in CTS. It also provides anatomical information that correlate well with electrophysiological findings in regard of the severity of median nerve compression.

  12. Cooling modifies mixed median and ulnar palmar studies in carpal tunnel syndrome.

    PubMed

    Araújo, Rogério Gayer Machado de; Kouyoumdjian, João Aris

    2007-09-01

    Temperature is an important and common variable that modifies nerve conduction study parameters in practice. Here we compare the effect of cooling on the mixed palmar median to ulnar negative peak-latency difference (PMU) in electrodiagnosis of carpal tunnel syndrome (CTS). Controls were 22 subjects (19 women, mean age 42.1 years, 44 hands). Patients were diagnosed with mild symptomatic CTS (25 women, mean age 46.6 years, 34 hands). PMU was obtained at the usual temperature, >32 degrees C, and after wrist/hand cooling to <27 degrees C in ice water. After cooling, there was a significantly greater increase in PMU and mixed ulnar palmar latency in patients versus controls. We concluded that cooling significantly modifies the PMU. We propose that the latencies of compressed nerve overreact to cooling and that this response could be a useful tool for incipient CTS electrodiagnosis. There was a significant latency overreaction of the ulnar nerve to cooling in CTS patients. We hypothesize that subclinical ulnar nerve compression is associated with CTS.

  13. 14. DETAIL, NORTH ABUTMENT, FROM EAST, SHOWING ABUTMENT, PORTION OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. DETAIL, NORTH ABUTMENT, FROM EAST, SHOWING ABUTMENT, PORTION OF SIMPLY ORNAMENTED EAST PARAPET, AND REMNANT OF STONE MASONRY ABUTMENT OF ORIGINAL (1890) FIFTH STREET VIADUCT - Fifth Street Viaduct, Spanning Bacon's Quarter Branch Valley on Fifth Street, Richmond, Independent City, VA

  14. Cost-Minimization Analysis of Open and Endoscopic Carpal Tunnel Release.

    PubMed

    Zhang, Steven; Vora, Molly; Harris, Alex H S; Baker, Laurence; Curtin, Catherine; Kamal, Robin N

    2016-12-07

    Carpal tunnel release is the most common upper-limb surgical procedure performed annually in the U.S. There are 2 surgical methods of carpal tunnel release: open or endoscopic. Currently, there is no clear clinical or economic evidence supporting the use of one procedure over the other. We completed a cost-minimization analysis of open and endoscopic carpal tunnel release, testing the null hypothesis that there is no difference between the procedures in terms of cost. We conducted a retrospective review using a private-payer and Medicare Advantage database composed of 16 million patient records from 2007 to 2014. The cohort consisted of records with an ICD-9 (International Classification of Diseases, Ninth Revision) diagnosis of carpal tunnel syndrome and a CPT (Current Procedural Terminology) code for carpal tunnel release. Payer fees were used to define cost. We also assessed other associated costs of care, including those of electrodiagnostic studies and occupational therapy. Bivariate comparisons were performed using the chi-square test and the Student t test. Data showed that 86% of the patients underwent open carpal tunnel release. Reimbursement fees for endoscopic release were significantly higher than for open release. Facility fees were responsible for most of the difference between the procedures in reimbursement: facility fees averaged $1,884 for endoscopic release compared with $1,080 for open release (p < 0.0001). Endoscopic release also demonstrated significantly higher physician fees than open release (an average of $555 compared with $428; p < 0.0001). Occupational therapy fees associated with endoscopic release were less than those associated with open release (an average of $237 per session compared with $272; p = 0.07). The total average annual reimbursement per patient for endoscopic release (facility, surgeon, and occupational therapy fees) was significantly higher than for open release ($2,602 compared with $1,751; p < 0.0001). Our data showed

  15. A new technique of single portal endoscopic carpal tunnel release.

    PubMed

    Ip, Wing-Yuk Josephine; Sweed, Tamer Ahmed; Fung, Kwok Keung Boris; Tipoe, George L; Pun, Tze Shing

    2012-03-01

    Since the first description of endoscopic carpal tunnel release (ECTR) in 1987 by Okutsu many endoscopic techniques have been developed, but the majority of the literature on ECTR has dealt with the Chow and Agee techniques. ECTR is indicated for carpal tunnel syndrome that is not responding to conservative treatment for 6 months. This new technique of ECTR is a single-portal technique using instruments originally designed for endoscopic cubital tunnel release, with no disposable instruments used. It also has the advantage of performing the release with the median nerve protected under direct vision. Ten cases were operated with this technique after performing the procedure on 8 hands of 4 fresh frozen cadavers. There were no neurovascular or tendon injuries with this technique and patients were satisfied with the results.

  16. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com; Baere, Thierry De, E-mail: Debaere@igr.fr

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 atmore » baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.« less

  17. Establishing and validating the fluorescent amyloid ligand h-FTAA (heptamer formyl thiophene acetic acid) to identify transthyretin amyloid deposits in carpal tunnel syndrome.

    PubMed

    Hahn, Katharina; Nilsson, K Peter R; Hammarström, Per; Urban, Peter; Meliss, Rolf Rüdiger; Behrens, Hans-Michael; Krüger, Sandra; Röcken, Christoph

    2017-06-01

    Transthyretin-derived (ATTR) amyloidosis is a frequent finding in carpal tunnel syndrome. We tested the following hypotheses: the novel fluorescent amyloid ligand heptameric formic thiophene acetic acid (h-FTAA) has a superior sensitivity for the detection of amyloid compared with Congo red-staining; Amyloid load correlates with patient gender and/or patient age. We retrieved 208 resection specimens obtained from 184 patients with ATTR amyloid in the carpal tunnel. Serial sections were stained with Congo red, h-FTAA and an antibody directed against transthyretin (TTR). Stained sections were digitalized and forwarded to computational analyses. The amount of amyloid was correlated with patient demographics. Amyloid stained intensely with h-FTAA and an anti-TTR-antibody. Congo red-staining combined with fluorescence microscopy was significantly less sensitive than h-FTAA-fluorescence and TTR-immunostaining: the highest percentage area was found in TTR-immunostained sections, followed by h-FTAA and Congo red. The Pearson correlation coefficient was .8 (Congo red vs. h-FTAA) and .9 (TTR vs. h-FTAA). Amyloid load correlated with patient gender, anatomical site and patient age. h-FTAA is a highly sensitive method to detect even small amounts of ATTR amyloid in the carpal tunnel. The staining protocol is easy and h-FTAA may be a much more sensitive procedure to detect amyloid at an earlier stage.

  18. Diagnosis and treatment of hand-arm vibration syndrome and its relationship to carpal tunnel syndrome.

    PubMed

    Falkiner, Sonja

    2003-07-01

    Hand-arm vibration syndrome (HAVS) is a condition associated with the use of vibrating tools that occurs mainly in men. It consists primarily of 'occupational' Raynaud disease and digital polyneuropathy. Carpal tunnel syndrome (CTS) is also associated with hand transmitted vibration exposure and can coexist with HAVS. This article examines recent papers on causation, diagnosis, relationship to CTS and treatment. A Medline search was conducted, as was a search of UK, USA and Australian government occupational health and safety websites. Published papers that were single case studies or of poor design were not included. There are no 'gold standard' diagnostic tests for HAVS. It can mimic CTS in temperate climates and can occur with CTS. This is the diagnostic challenge when a male worker presents with apparent CTS symptoms. If he has worked with vibrating tools for many years, a diagnosis of HAVS or co-diagnosis of HAVS should be considered before a diagnosis of pure CTS is made. Nonwork risk factors for HAVS are predisposition, smoking, and exposure to vibration outside work. Cessation of exposure (and smoking) and redeployment is a critical part of treatment due to the dose response relationship of HAVS. This contrasts with adequately treated CTS, where the vast majority of workers can return to pre-injury duties. In severe cases, calcium antagonists are also used, but treatment is often ineffective. Few workplaces in Australia manage vibration risk or conduct screening to identify workers with early HAVS who should be redeployed. Local doctors have an important opportunity to diagnose HAVS and to make recommendations to the workplace on redeployment as part of treatment before symptoms become irreversible.

  19. Measurement of the rotational misfit and implant-abutment gap of all-ceramic abutments.

    PubMed

    Garine, Wael N; Funkenbusch, Paul D; Ercoli, Carlo; Wodenscheck, Joseph; Murphy, William C

    2007-01-01

    The specific aims of this study were to measure the implant and abutment hexagonal dimensions, to measure the rotational misfit between implant and abutments, and to correlate the dimension of the gap present between the abutment and implant hexagons with the rotational misfit of 5 abutment-implant combinations from 2 manufacturers. Twenty new externally hexed implants (n = 10 for Nobel Biocare; n = 10 for Biomet/3i) and 50 new abutments were used (n = 10; Procera Zirconia; Procera Alumina; Esthetic Ceramic Abutment; ZiReal; and GingiHue post ZR Zero Rotation abutments). The mating surfaces of all implants and abutments were imaged with a scanning electron microscope before and after rotational misfit measurements. The distances between the corners and center of the implant and abutment hexagon were calculated by entering their x and y coordinates, measured on a measuring microscope, into Pythagoras' theorem. The dimensional difference between abutment and implant hexagons was calculated and correlated with the rotational misfit, which was recorded using a precision optical encoder. Each abutment was rotated (3 times/session) clockwise and counterclockwise until binding. Analysis of variance and Student-Newman-Keuls tests were used to compare rotational misfit among groups (alpha = .05). With respect to rotational misfit, the abutment groups were significantly different from one another (P < .001), with the exception of the Procera Zirconia and Esthetic Ceramic groups (P = .4). The mean rotational misfits in degrees were 4.13 +/- 0.68 for the Procera Zirconia group, 3.92 +/- 0.62 for the Procera Alumina group, 4.10 +/- 0.67 for the Esthetic Ceramic group, 3.48 +/- 0.40 for the ZiReal group, and 1.61 +/- 0.24 for the GingiHue post ZR group. There was no correlation between the mean implant-abutment gap and rotational misfit. Within the limits of this study, machining inconsistencies of the hexagons were found for all implants and abutments tested. The GingiHue Post

  20. Clinical course, costs and predictive factors for response to treatment in carpal tunnel syndrome: the PALMS study protocol.

    PubMed

    Jerosch-Herold, Christina; Shepstone, Lee; Wilson, Edward C F; Dyer, Tony; Blake, Julian

    2014-02-07

    Carpal tunnel syndrome (CTS) is the most common neuropathy of the upper limb and a significant contributor to hand functional impairment and disability. Effective treatment options include conservative and surgical interventions, however it is not possible at present to predict the outcome of treatment. The primary aim of this study is to identify which baseline clinical factors predict a good outcome from conservative treatment (by injection) or surgery in patients diagnosed with carpal tunnel syndrome. Secondary aims are to describe the clinical course and progression of CTS, and to describe and predict the UK cost of CTS to the individual, National Health Service (NHS) and society over a two year period. In this prospective observational cohort study patients presenting with clinical signs and symptoms typical of CTS and in whom the diagnosis is confirmed by nerve conduction studies are invited to participate. Data on putative predictive factors are collected at baseline and follow-up through patient questionnaires and include standardised measures of symptom severity, hand function, psychological and physical health, comorbidity and quality of life. Resource use and cost over the 2 year period such as prescribed medications, NHS and private healthcare contacts are also collected through patient self-report at 6, 12, 18 and 24 months. The primary outcome used to classify treatment success or failures will be a 5-point global assessment of change. Secondary outcomes include changes in clinical symptoms, functioning, psychological health, quality of life and resource use. A multivariable model of factors which predict outcome and cost will be developed. This prospective cohort study will provide important data on the clinical course and UK costs of CTS over a two-year period and begin to identify predictive factors for treatment success from conservative and surgical interventions.

  1. Clinical course, costs and predictive factors for response to treatment in carpal tunnel syndrome: the PALMS study protocol

    PubMed Central

    2014-01-01

    Background Carpal tunnel syndrome (CTS) is the most common neuropathy of the upper limb and a significant contributor to hand functional impairment and disability. Effective treatment options include conservative and surgical interventions, however it is not possible at present to predict the outcome of treatment. The primary aim of this study is to identify which baseline clinical factors predict a good outcome from conservative treatment (by injection) or surgery in patients diagnosed with carpal tunnel syndrome. Secondary aims are to describe the clinical course and progression of CTS, and to describe and predict the UK cost of CTS to the individual, National Health Service (NHS) and society over a two year period. Methods/Design In this prospective observational cohort study patients presenting with clinical signs and symptoms typical of CTS and in whom the diagnosis is confirmed by nerve conduction studies are invited to participate. Data on putative predictive factors are collected at baseline and follow-up through patient questionnaires and include standardised measures of symptom severity, hand function, psychological and physical health, comorbidity and quality of life. Resource use and cost over the 2 year period such as prescribed medications, NHS and private healthcare contacts are also collected through patient self-report at 6, 12, 18 and 24 months. The primary outcome used to classify treatment success or failures will be a 5-point global assessment of change. Secondary outcomes include changes in clinical symptoms, functioning, psychological health, quality of life and resource use. A multivariable model of factors which predict outcome and cost will be developed. Discussion This prospective cohort study will provide important data on the clinical course and UK costs of CTS over a two-year period and begin to identify predictive factors for treatment success from conservative and surgical interventions. PMID:24507749

  2. Central sensitization does not identify patients with carpal tunnel syndrome who are likely to achieve short-term success with physical therapy.

    PubMed

    Fernández-de-Las-Peñas, César; Cleland, Joshua A; Ortega-Santiago, Ricardo; de-la-Llave-Rincon, Ana Isabel; Martínez-Perez, Almudena; Pareja, Juan A

    2010-11-01

    The aim of the current study was to identify whether hyperexcitability of the central nervous system is a prognostic factor for individuals with carpal tunnel syndrome (CTS) likely to experience rapid and clinical self-reported improvement following a physical therapy program including soft tissue mobilization and nerve slider neurodynamic interventions. Women presenting with clinical and electrophysiological findings of CTS were involved in a prospective single-arm trial. Participants underwent a standardized examination and then a physical therapy session. The physical therapy sessions included both soft tissue mobilization directed at the anatomical sites of potential median nerve entrapment and a passive nerve slider neurodynamic technique targeted to the median nerve. Pressure pain thresholds (PPT) over the median, radial and ulnar nerves, C5-C6 zygapophyseal joint, carpal tunnel and tibialis anterior muscle were assessed bilaterally. Additionally, thermal detection and pain thresholds were measured over the carpal tunnel and thenar eminence bilaterally to evaluate central nervous system excitability. Subjects were classified as responders (having achieved a successful outcome) or non-responders based on self-perceived recovery. Variables were entered into a stepwise logistic regression model to determine the most accurate variables for determining prognosis. Data from 72 women were included in the analysis, of which 35 experienced a successful outcome (48.6%). Three variables including PPT over the C5-C6 joint affected side <137 kPa, HPT carpal tunnel affected side <39.6º and general health >66 points were identified. If 2 out of 3 variables were present (LR + 14.8), the likelihood of success increased from 48.6 to 93.3%. We identified 3 factors that may be associated with a rapid clinical response to both soft tissue mobilization and nerve slider neurodynamic techniques targeted to the median nerve in women presenting with CTS. Our results support that

  3. Associations between workplace factors and carpal tunnel syndrome: A multi-site cross sectional study.

    PubMed

    Fan, Z Joyce; Harris-Adamson, Carisa; Gerr, Fred; Eisen, Ellen A; Hegmann, Kurt T; Bao, Stephen; Silverstein, Barbara; Evanoff, Bradley; Dale, Ann Marie; Thiese, Matthew S; Garg, Arun; Kapellusch, Jay; Burt, Susan; Merlino, Linda; Rempel, David

    2015-05-01

    Few large epidemiologic studies have used rigorous case criteria, individual-level exposure measurements, and appropriate control for confounders to examine associations between workplace psychosocial and biomechanical factors and carpal tunnel syndrome (CTS). Pooling data from five independent research studies, we assessed associations between prevalent CTS and personal, work psychosocial, and biomechanical factors while adjusting for confounders using multivariable logistic regression. Prevalent CTS was associated with personal factors of older age, obesity, female sex, medical conditions, previous distal upper extremity disorders, workplace measures of peak forceful hand activity, a composite measure of force and repetition (ACGIH Threshold Limit Value for Hand Activity Level), and hand vibration. In this cross-sectional analysis of production and service workers, CTS prevalence was associated with workplace and biomechanical factors. The findings were similar to those from a prospective analysis of the same cohort with differences that may be due to recall bias and other factors. © 2015 Wiley Periodicals, Inc.

  4. Long-term symptomatic, functional, and work outcomes of carpal tunnel syndrome among construction workers.

    PubMed

    Evanoff, Bradley; Gardner, Bethany T; Strickland, Jaime R; Buckner-Petty, Skye; Franzblau, Alfred; Dale, Ann Marie

    2016-05-01

    The long-term outcomes of carpal tunnel syndrome (CTS) including symptoms, functional status, work disability, and economic impact are unknown. We conducted a retrospective study of 234 active construction workers with medical claims for CTS and 249 workers without CTS claims; non-cases were matched on age, trade, and insurance eligibility. We conducted telephone interviews with cases and non-cases and collected administrative data on work hours. Compared to non-cases, CTS cases were more likely to report recurrent hand symptoms, decreased work productivity/quality, decreased performance of physical work demands, and greater functional limitations. Surgical cases showed larger improvements on multiple outcomes than non-surgical cases. Minimal differences in paid work hours were seen between cases and non-cases in the years preceding and following CTS claims. Persistent symptoms and functional impairments were present several years after CTS diagnosis. Long-term functional limitations shown by this and other studies indicate the need for improved prevention and treatment. © 2016 Wiley Periodicals, Inc.

  5. Finite element analysis for transverse carpal ligament tensile strain and carpal arch area.

    PubMed

    Yao, Yifei; Erdemir, Ahmet; Li, Zong-Ming

    2018-05-17

    Mechanics of carpal tunnel soft tissue, such as fat, muscle and transverse carpal ligament (TCL), around the median nerve may render the median nerve vulnerable to compression neuropathy. The purpose of this study was to understand the roles of carpal tunnel soft tissue mechanical properties and intratunnel pressure on the TCL tensile strain and carpal arch area (CAA) using finite element analysis (FEA). Manual segmentation of the thenar muscles, skin, fat, TCL, hamate bone, and trapezium bone in the transverse plane at distal carpal tunnel were obtained from B-mode ultrasound images of one cadaveric hand. Sensitivity analyses were conducted to examine the dependence of TCL tensile strain and CAA on TCL elastic modulus (0.125-10 MPa volar-dorsally; 1.375-110 MPa transversely), skin-fat and thenar muscle initial shear modulus (1.6-160 kPa for skin-fat; 0.425-42.5 kPa for muscle), and intratunnel pressure (60-480 mmHg). Predictions of TCL tensile strain under different intratunnel pressures were validated with the experimental data obtained on the same cadaveric hand. Results showed that skin, fat and muscles had little effect on the TCL tensile strain and CAA changes. However, TCL tensile strain and CAA increased with decreased elastic modulus of TCL and increased intratunnel pressure. The TCL tensile strain and CAA increased linearly with increased pressure while increased exponentially with decreased elastic modulus of TCL. Softening the TCL by decreasing the elastic modulus may be an alternative clinical approach to carpal tunnel expansion to accommodate elevated intratunnel pressure and alleviate median nerve compression neuropathy. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Conservative treatment in patients with mild to moderate carpal tunnel syndrome: A systematic review.

    PubMed

    Jiménez Del Barrio, S; Bueno Gracia, E; Hidalgo García, C; Estébanez de Miguel, E; Tricás Moreno, J M; Rodríguez Marco, S; Ceballos Laita, L

    2016-07-22

    Carpal tunnel syndrome (CTS) is the most common peripheral neuropathy. It is characterised by the compression of the median nerve in the carpal tunnel. CTS presents a high prevalence and it is a disabling condition from the earliest stages. Severe cases are usually treated surgically, while conservative treatment is recommended in mild to moderate cases. The aim of this systematic review is to present the conservative treatments and determine their effectiveness in mild-to-moderate cases of CTS over the last 15 years. A systematic review was performed according to PRISMA criteria. We used the Medline, PEDro, and Cochrane databases to find and select randomised controlled clinical trials evaluating the effects of conservative treatment on the symptoms and functional ability of patients with mild to moderate CTS; 32 clinical trials were included. There is evidence supporting the effectiveness of oral drugs, although injections appear to be more effective. Splinting has been shown to be effective, and it is also associated with use of other non-pharmacological techniques. Assessments of the use of electrotherapy techniques alone have shown no conclusive results about their effectiveness. Other soft tissue techniques have also shown good results but evidence on this topic is limited. Various treatment combinations (drug and non-pharmacological treatments) have been proposed without conclusive results. Several conservative treatments are able to relieve symptoms and improve functional ability of patients with mild-to-moderate CTS. These include splinting, oral drugs, injections, electrotherapy, specific manual techniques, and neural gliding exercises as well as different combinations of the above. We have been unable to describe the best technique or combination of techniques due to the limitations of the studies; therefore, further studies of better methodological quality are needed. Copyright © 2016 Sociedad Española de Neurología. Publicado por Elsevier España, S

  7. Prevalence, course and determinants of carpal tunnel syndrome symptoms during pregnancy: a prospective study.

    PubMed

    Meems, M; Truijens, Sem; Spek, V; Visser, L H; Pop, V J M

    2015-07-01

    To investigate the prevalence, severity and relation to fluid retention of self-reported pregnancy-related carpal tunnel syndrome (CTS) symptoms in a large sample of pregnant women. A prospective longitudinal cohort study. Dutch women who became pregnant between January 2013 and January 2014 in the southeast of The Netherlands. A total of 639 Dutch pregnant women. Baseline characteristics were assessed at 12 weeks' gestation. CTS symptoms were assessed using the Boston Carpal Tunnel Questionnaire (BCTQ) at 32 weeks and during the first postpartum week regarding the last weeks of pregnancy. Fluid retention, sleeping problems and depressive symptoms (using the Edinburgh Depression Scale) were assessed at several time points during pregnancy. BCTQ scores, fluid retention and sleeping problems. Of the 639 women, 219 (34%) reported CTS symptoms during pregnancy. Total mean scores on the BCTQ were significantly higher after 32 weeks' than up to 32 weeks' gestation. Most women experienced mild to moderate symptoms. Pregnant women with CTS symptoms reported significantly higher levels of fluid retention during gestation compared with pregnant women without CTS symptoms [F = 60.6, df (1598), P < 0.001], adjusted for body mass index (BMI), age, parity, and depression scores. Higher scores on fluid retention throughout the pregnancy were significantly related to CTS (OR = 1.8, 95%CI 1.5, 2.1, P < 0.001). Finally, the occurrence of CTS was independently related to sleeping problems. Although the severity of symptoms and functional impairment of CTS were relatively mild, health care professionals should be aware of the high prevalence. The occurrence of CTS symptoms is significantly higher in women who report fluid retention during gestation and it can contribute to sleeping problems. © 2015 Royal College of Obstetricians and Gynaecologists.

  8. Fracture Resistance of Implant Abutments Following Abutment Alterations by Milling the Margins: An In Vitro Study.

    PubMed

    Patankar, Anuya; Kheur, Mohit; Kheur, Supriya; Lakha, Tabrez; Burhanpurwala, Murtuza

    2016-12-01

    This in vitro study evaluated the effect of different levels of preparation of an implant abutment on its fracture resistance. The study evaluated abutments that incorporated a platform switch (Myriad Plus Abutments, Morse Taper Connection) and Standard abutments (BioHorizons Standard Abutment, BioHorizons Inc). Each abutment was connected to an appropriate implant and mounted in a self-cured resin base. Based on the abutment preparation depths, 3 groups were created for each abutment type: as manufactured, abutment prepared 1 mm apical to the original margin, and abutment prepared 1.5 mm to the original margin. All the abutments were prepared in a standardized manner to incorporate a 0.5 mm chamfer margin uniformly. All the abutments were torqued to 30 Ncm on their respective implants. They were then subjected to loading until failure in a universal testing machine. Abutments with no preparation showed the maximum resistance to fracture for both groups. As the preparation depth increased, the fracture resistance decreased. The fracture resistance of implant abutment junction decreases as the preparation depth increases.

  9. Hypothalamus and amygdala response to acupuncture stimuli in Carpal Tunnel Syndrome.

    PubMed

    Napadow, V; Kettner, N; Liu, J; Li, M; Kwong, K K; Vangel, M; Makris, N; Audette, J; Hui, K K S

    2007-08-01

    Brain processing of acupuncture stimuli in chronic neuropathic pain patients may underlie its beneficial effects. We used fMRI to evaluate verum and sham acupuncture stimulation at acupoint LI-4 in Carpal Tunnel Syndrome (CTS) patients and healthy controls (HC). CTS patients were retested after 5 weeks of acupuncture therapy. Thus, we investigated both the short-term brain response to acupuncture stimulation, as well as the influence of longer-term acupuncture therapy effects on this short-term response. CTS patients responded to verum acupuncture with greater activation in the hypothalamus and deactivation in the amygdala as compared to HC, controlling for the non-specific effects of sham acupuncture. A similar difference was found between CTS patients at baseline and after acupuncture therapy. For baseline CTS patients responding to verum acupuncture, functional connectivity was found between the hypothalamus and amygdala--the less deactivation in the amygdala, the greater the activation in the hypothalamus, and vice versa. Furthermore, hypothalamic response correlated positively with the degree of maladaptive cortical plasticity in CTS patients (inter-digit separation distance). This is the first evidence suggesting that chronic pain patients respond to acupuncture differently than HC, through a coordinated limbic network including the hypothalamus and amygdala.

  10. Efficacy of Keyhole Approach to Carpal Tunnel Syndrome under Ambulatory Strategy

    PubMed Central

    García-Mercado, César J.; Segura-Durán, Iván; Zepeda-Gutiérrez, Luis A.

    2017-01-01

    The carpal tunnel syndrome is one of the most common entrapment neuropathies found in humans. Currently, the gold standard is surgical treatment using different modalities. The minimally invasive strategy with high resolution capacity and less morbidity is still a challenge. Methods. Prospective nonrandomised clinical trial in which a minimally invasive microsurgical approach was used following the keyhole principle in 55 consecutive patients and 65 hands under local anesthesia and ambulatory strategy. They were evaluated with stringent inclusion criteria with the Levine severity and functional status scale and with a 2-year follow-up. Results. 90% showed immediate improvement dropping to grades 1-2 in all items of the scale referring to pain and numbness. 97% reported improvement, as of the first month, and 3% reported persistence of symptoms, although at a lesser degree and with no functional limitation. No incidents were identified during the procedure and 98% of patients were discharged within an hour after the surgical procedure. Conclusions. The microsurgical approach described following the keyhole principle is a treatment option that, under local anesthesia and ambulatory management, may represent an alternative strategy of an effective treatment reducing the morbidity. This trial is registered with Clinical Trials Protocol Identifier NCT03062722. PMID:28484650

  11. Neuromuscular ultrasound in patients with carpal tunnel syndrome and normal nerve conduction studies.

    PubMed

    Aseem, Fazila; Williams, Jessica W; Walker, Francis O; Cartwright, Michael S

    2017-06-01

    Nerve conduction studies (NCS) are sensitive for carpal tunnel syndrome (CTS), but a small proportion of patients with clinical CTS have normal NCS. This retrospective study was designed to assess the neuromuscular ultrasound findings in a group of CTS patients. The electronic medical record was reviewed by a neurologist to identify patients who had a diagnosis of CTS with normal NCS, including either mixed median-ulnar comparison or transcarpal sensory studies, and complete neuromuscular ultrasound evaluation for CTS. Fourteen individuals (22 wrists) met all criteria. A total of 92.3% had median nerve cross-sectional area enlargement at the wrist (mean 16.3 mm 2 ), 100% had increased wrist-to-forearm median nerve area ratio (mean 2.4), 82.4% had decreased median nerve echogenicity, 75.0% had decreased median nerve mobility, and 7.1% had increased median nerve vascularity. A large proportion of patients with clinical CTS but normal NCS have abnormal neuromuscular ultrasound findings. Muscle Nerve 55: 913-915, 2017. © 2016 Wiley Periodicals, Inc.

  12. Two-point discrimination and kinesthetic sense disorders in productive age individuals with carpal tunnel syndrome.

    PubMed

    Wolny, Tomasz; Saulicz, Edward; Linek, Paweł; Myśliwiec, Andrzej

    2016-06-16

    The aim of this study was to evaluate two-point discrimination (2PD) sense and kinesthetic sense dysfunctions in carpal tunnel syndrome (CTS) patients compared with a healthy group. The 2PD sense, muscle force, and kinesthetic differentiation (KD) of strength; the range of motion in radiocarpal articulation; and KD of motion were assessed. The 2PD sense assessment showed significantly higher values in all the examined fingers in the CTS group than in those in the healthy group (p<0.01). There was a significant difference in the percentage value of error in KD of pincer and cylindrical grip (p<0.01) as well as in KD of flexion and extension movement in the radiocarpal articulation (p<0.01) between the studied groups. There are significant differences in the 2PD sense and KD of strength and movement between CTS patients compared with healthy individuals.

  13. Infrared thermography based on artificial intelligence as a screening method for carpal tunnel syndrome diagnosis.

    PubMed

    Jesensek Papez, B; Palfy, M; Mertik, M; Turk, Z

    2009-01-01

    This study further evaluated a computer-based infrared thermography (IRT) system, which employs artificial neural networks for the diagnosis of carpal tunnel syndrome (CTS) using a large database of 502 thermal images of the dorsal and palmar side of 132 healthy and 119 pathological hands. It confirmed the hypothesis that the dorsal side of the hand is of greater importance than the palmar side when diagnosing CTS thermographically. Using this method it was possible correctly to classify 72.2% of all hands (healthy and pathological) based on dorsal images and > 80% of hands when only severely affected and healthy hands were considered. Compared with the gold standard electromyographic diagnosis of CTS, IRT cannot be recommended as an adequate diagnostic tool when exact severity level diagnosis is required, however we conclude that IRT could be used as a screening tool for severe cases in populations with high ergonomic risk factors of CTS.

  14. [Dental implant restoration abutment selection].

    PubMed

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  15. Factors affecting symptoms and functionality of patients with carpal tunnel syndrome: a retrospective study

    PubMed Central

    Yucel, Hulya

    2015-01-01

    [Purpose] The aim of this retrospective study was to determine the associations between clinical, physical, and neurophysiological outcomes and self-reported symptoms and functions of patients after surgical carpal tunnel release. [Subjects and Methods] Among 261 patients who had undergone open surgical carpal tunnel release within the last three years, 83 (mean age 50.27 ± 11.13 years) participated in this study. Their socio-demographics and comorbidities were recorded. The intensity of pain, paresthesia, and fatigue symptoms in the hand were assessed by means of a Visual Analogue Scale, the Semmes-Weinstein Monofilaments test of light touch pressure sensation, and Jamar dynamometry for measurement of grip and pinch strengths. The Boston Carpal Tunnel Questionnaire evaluated the severity of symptoms and hand functional status, and the variables were analyzed by multivariate linear regression. [Results] The severity of the symptoms and functional status of release surgery patients was associated with diabetes mellitus, migraine, night pain, paresthesia and fatigue symptoms, impaired light touch pressure, and lack of medical treatment. [Conclusion] Appropriate post-surgery treatment programs for these factors should be taken into consideration to help patients obtain optimal functionality and health in their daily lives. PMID:25995565

  16. Do exposure limits for hand-transmitted vibration prevent carpal tunnel syndrome?

    PubMed

    Gillibrand, S; Ntani, G; Coggon, D

    2016-07-01

    An apparently high frequency of carpal tunnel syndrome (CTS) among shipyard workers undergoing health surveillance because of exposure to hand-transmitted vibration (HTV) prompted concerns that current regulatory limits on exposure might not protect adequately against the disorder. To explore whether within regulatory limits, higher exposures to HTV predispose to CTS. As part of a retrospective audit, we compared duration and current intensity of exposure to HTV in cases with new-onset CTS and controls matched for age. Conditional logistic regression was used to quantify associations, which were summarized by odds ratios (ORs) and 95% confidence intervals (CIs). There were 23 cases and 55 controls. After adjustment for body mass index and previous diagnosis of diabetes, no clear associations were observed either with duration of exposure to HTV or with current intensity of exposure. Risk was non-significantly elevated in men with ≥30 years' exposure to HTV (OR 1.6), but in the highest category of current exposure [8-h energy-equivalent frequency-weighted acceleration (A8) ≥ 4.0 m/s(2)], risk was lower than that in the reference category (A8 < 2.5 m/s(2)). Moreover, there was a significantly reduced risk of CTS in men with a previous diagnosis of hand-arm vibration syndrome (HAVS) (OR 0.2, 95% CI 0.1-0.9). We found no evidence that below the current limit for A(8) of 5 m/s(2), higher exposures to HTV predispose to CTS. However, care should be taken not to overlook the possibility of treatable CTS when workers with diagnosed HAVS present with new or worsening sensory symptoms in the hand. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    PubMed

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  18. Personal risk factors for carpal tunnel syndrome in female visual display unit workers.

    PubMed

    Riccò, Matteo; Cattani, Silvia; Signorelli, Carlo

    2016-11-18

    Carpal tunnel syndrome (CTS) is the most common nerve entrapment syndrome, which since the beginning of the seventies has been linked to the keyboard and visual display unit (VDU). The objective of this study was to investigate the prevalence and personal factors associated with CTS in female VDU workers in Italy. Participants in this study were female adult subjects, working ≥ 20 h/week (N = 631, mean age 38.14±7.81 years, mean working age 12.9±7.24 years). Signs and symptoms were collected during compulsory occupational medical surveillance. The binary logistic regression was used to estimate adjusted odds ratios for the factors of interest. Diagnosis of CTS was reported in 48 cases (7.6%, 11 of them or 1.7% after a surgical correction) for the incidence of 5.94/1000 person-years. In general, signs and symptoms of CTS were associated with the following demographic factors: previous trauma of upper limb (adjusted odds ratio (ORa) = 8.093, 95% confidence interval (CI): 2.347-27.904), history (> 5 years) of oral contraceptives therapy/hormone replacement therapy (ORa = 3.77, 95% CI: 1.701-8.354) and cervical spine signs/symptoms (ORa = 4.565, 95% CI: 2.281-9.136). The prevalence of CTS was similar to the estimates for the general population of Italy. Among personal risk factors, hormone therapy, previous trauma of the upper limb and signs/symptoms of the cervical spine appeared to be associated with a higher risk of CTS syndrome. Eventually, the results reinforce interpretation of CTS in VDU workers as a work-related musculoskeletal disorder rather than a classical occupational disease. Int J Occup Med Environ Health 2016;29(6):927-936. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  19. Treatment of Carpal Tunnel Syndrome in pregnancy with Polarized Polychromatic Non-coherent Light (Bioptron Light): A Preliminary, Prospective, Open Clinical Trial.

    PubMed

    Dimitrios, Stasinopoulos; Stasinopoulos, Loannis

    2017-12-31

    The aim of this trial was to assess the efficacy of polarized polychromatic noncoherent light (Bioptron light) in the treatment of Carpal Tunnel Syndrome (CTS) in pregnancy. An uncontrolled experimental study was conducted in pregnant patients with CTS who visited our clinic from January 2006 to January 2010. Bioptron light (480-3400 nm; 95% polarization; 40 mW/cm 2 ; and 2.4 J/cm 2 ) was administered perpendicular to the carpal tunnel area. The irradiation time for each session was 6 min at an operating distance of 5-10 cm from the carpal tunnel area, twice each day, five days per week for 2 weeks. Pain and paraesthesia using a visual analogue scale (VAS) and finger pinch strength were evaluated at the end of treatment (week 2) and 1-month (week 6) after the end of treatment. The Student'sttest was used and p values < 0.05 were accepted as statistically significant. 46 patients participated in the study. The mean age of subjects was 27.6 years (range 22-37). The patient population had a mean duration of CTS of 2.3 months (range 1-4). All patients were in the third trimester. Pain and paraesthesia decreased at the end of treatment and at the 1-month follow-up, whereas the finger pinch strength increased at the end of treatment and at the 1-month follow-up. In conclusion, the results of the present study suggest that Bioptron light is a reliable, safe, and effective treatment option in pregnant patients with CTS. Controlled clinical trials are needed to establish the absolute and relative effectiveness of this intervention.

  20. Two-point discrimination and kinesthetic sense disorders in productive age individuals with carpal tunnel syndrome

    PubMed Central

    Wolny, Tomasz; Saulicz, Edward; Linek, Paweł; Myśliwiec, Andrzej

    2016-01-01

    Objectives: The aim of this study was to evaluate two-point discrimination (2PD) sense and kinesthetic sense dysfunctions in carpal tunnel syndrome (CTS) patients compared with a healthy group. Methods: The 2PD sense, muscle force, and kinesthetic differentiation (KD) of strength; the range of motion in radiocarpal articulation; and KD of motion were assessed. Results: The 2PD sense assessment showed significantly higher values in all the examined fingers in the CTS group than in those in the healthy group (p<0.01). There was a significant difference in the percentage value of error in KD of pincer and cylindrical grip (p<0.01) as well as in KD of flexion and extension movement in the radiocarpal articulation (p<0.01) between the studied groups. Conclusions: There are significant differences in the 2PD sense and KD of strength and movement between CTS patients compared with healthy individuals. PMID:27108640

  1. Is carpal tunnel syndrome related to computer exposure at work? A review and meta-analysis.

    PubMed

    Mediouni, Zakia; de Roquemaurel, Alexis; Dumontier, Christian; Becour, Bertrand; Garrabe, Hélène; Roquelaure, Yves; Descatha, Alexis

    2014-02-01

    A meta-analysis on epidemiological studies was undertaken to assess association between carpal tunnel syndrome (CTS) and computer work. Four databases (PubMed, Embase, Web of Science, and Base de Donnees de Sante Publique) were searched with cross-references from published reviews. We included recent studies, original epidemiological studies for which the association was assessed with blind reviewing with control group. Relevant associations were extracted, and a metarisk was calculated using the generic variance approach (meta-odds ratio [meta-OR]). Six studies met the criteria for inclusion. Results are contradictory because of heterogeneous work exposure. The meta-OR for computer use was 1.67 (95% confidence interval [CI], 0.79 to 3.55). The meta-OR for keyboarding was 1.11 (95% CI, 0.62 to 1.98) and for mouse 1.94 (95% CI, 0.90 to 4.21). It was not possible to show an association between computer use and CTS, although some particular work circumstances may be associated with CTS.

  2. The Effect of Written Information on Recall of Surgical Risks of Carpal Tunnel Release Surgery: A Randomized Controlled Study.

    PubMed

    Wong, Alison L; Martin, Janet; Tang, David; LeBlanc, Martin; Morris, Steven F; Paletz, Justin; Stein, John; Wong, Michael J; Bezuhly, Michael

    2016-12-01

    Written information has been thought to help patients recall surgical risks discussed during the informed consent process, but has not been assessed for carpal tunnel release, a procedure with the rare but serious risk of complex regional pain syndrome. The authors' objective was to determine whether providing a pamphlet would improve patients' ability to remember the risks of surgery. Sixty patients seen for carpal tunnel release were included in this prospective, single-blind, randomized study. Patients received either a written pamphlet of the risks of surgery or no additional information following a standardized consultation. Two weeks after the initial consultation, patients were contacted to assess their risk recall and whether they had read about the operation from any source. There was no difference in terms of the number of risks recalled between pamphlet (1.33 ± 1.21) or control groups (1.45 ± 1.22; p = 0.73). Recall of infection was better in the pamphlet group (p < 0.05). No patients remembered complex regional pain syndrome. There was no difference in the proportion of people who read additional information about carpal tunnel release surgery between the pamphlet (34.8 percent) and control groups (21.4 percent; p = 0.39), but reading about carpal tunnel release surgery was associated with improved recall (2.45 ± 1.13 versus 0.77 ± 0.91; p < 0.01). Reading about surgery improved risk recall, but providing this information in the form of a pamphlet did not, nor did it affect patients' ability to recall the risk of complex regional pain syndrome. These results demonstrate that surgeons should implement additional measures to improve comprehension of surgical risks. Therapeutic, I.

  3. 6. VIEW OF SOUTH ABUTMENT. MASONRY ON BOTH ABUTMENTS IS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF SOUTH ABUTMENT. MASONRY ON BOTH ABUTMENTS IS LAID UP IN SEMI-COURSED RUBBLE PATTERN. VIEW LOOKING SOUTHEAST. - Montgomery County Bridge No. 221, Metz Road spanning Towamencin Creek, Skippack, Montgomery County, PA

  4. Carpal Tunnel Syndrome

    MedlinePlus

    ... Keep me signed in Passwords are Case Sensitive. Ex. Enter smith as follows: Smith Forgot Username/Password? ... Erythematosus (Juvenile) Takayasu's Arteritis Tendinitis & Bursitis Tumor Necrosis Factor Receptor Associated Periodic Syndrome (Juvenile) Vasculitis Enfermedades y ...

  5. Association between wrist ratio and carpal tunnel syndrome: Effect modification by body mass index.

    PubMed

    Thiese, Matthew S; Merryweather, Andrew; Koric, Alzina; Ott, Ulrike; Wood, Eric M; Kapellusch, Jay; Foster, James; Garg, Arun; Deckow-Schaefer, Gwen; Tomich, Suzanna; Kendall, Richard; Drury, David L; Wertsch, Jacqueline; Hegmann, Kurt T

    2017-12-01

    Previous studies have reported higher wrist ratios (WR) related to carpal tunnel syndrome (CTS) but have not assessed effect modification by obesity and may have inadequately controlled for confounders. Baseline data of a multicenter prospective cohort study were analyzed. CTS was defined by nerve conduction study (NCS) criteria and symptoms. Among the 1,206 participants, a square-shaped wrist was associated with CTS after controlling for confounders (prevalence ratio = 2.27; 95% confidence interval [95% CI], 1.33-3.86). Body mass index (BMI) was a strong effect modifier on the relationship between WR and both CTS and abnormal NCS results, with normal weight strata of rectangular versus square wrists = 8.18 (95% CI, 1.63-49.96) and 7.12 (95% CI, 2.19-23.16), respectively. A square wrist is significantly associated with CTS after controlling for confounders. Effect modification by high BMI masked the eightfold magnitude adjusted relationship seen between WR and CTS among normal weight participants. Muscle Nerve 56: 1047-1053, 2017. © 2017 Wiley Periodicals, Inc.

  6. The Prevalence of Carpal Tunnel Syndrome in Latino Poultry Processing Workers and Other Latino Manual Workers

    PubMed Central

    Cartwright, Michael S.; Walker, Francis O.; Blocker, Jill N.; Schulz, Mark R.; Arcury, Thomas A.; Grzywacz, Joseph G.; Mora, Dana; Chen, Haiying; Marín, Antonio J.; Quandt, Sara A.

    2011-01-01

    Objective To determine the prevalence of carpal tunnel syndrome (CTS) in Latino poultry processing workers. Methods Symptoms and nerve conduction studies were used to prospectively assess 287 Latino poultry processing workers and 226 Latinos in other manual labor occupations. Results The prevalence of CTS was higher in poultry processing (8.7%) compared to non-poultry manual workers (4.0%, p < 0.0001). The adjusted odds ratio for the prevalence of CTS in poultry workers was 2.51 (95% CI of 1.80 to 3.50) compared to non-poultry workers. Within the poultry workers, those who performed packing, sanitation, and chilling had a trend toward less CTS than those who performed tasks requiring more repetitive and strenuous hand movements. Discussion Latino poultry processing workers have a high prevalence of CTS, which likely results from the repetitive and strenuous nature of the work. PMID:22258161

  7. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    PubMed

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  8. The effect of the involvement of the dominant or non-dominant hand on grip/pinch strengths and the Levine score in patients with carpal tunnel syndrome.

    PubMed

    Zyluk, A; Walaszek, I

    2012-06-01

    The Levine questionnaire is a disease-oriented instrument developed for outcome measurement of carpal tunnel syndrome (CTS) management. The objective of this study was to compare Levine scores in patients with unilateral CTS, involving the dominant or non-dominant hand, before and after carpal tunnel release. Records of 144 patients, 126 women (87%) and 18 men (13%) aged a mean of 58 years with unilateral CTS, treated operatively, were analysed. The dominant hand was involved in 100 patients (69%), the non-dominant in 44 (31%). The parameters were analysed pre-operatively, and at 1 and 6 months post-operatively. A comparison of Levine scores in patients with the involvement of the dominant or non-dominant hand showed no statistically significant differences at baseline and any of the follow-up measurements. Statistically significant differences were noted in total grip strength at baseline and at 6 month assessments and in key-pinch strength at 1 and 6 months.

  9. The mini-incision technique for carpal tunnel release using nasal instruments in Chinese patients.

    PubMed

    Chen, Yanhua; Ji, Wei; Li, Tao; Cong, Xiaobin; Chen, Zhenbing

    2017-08-01

    Treatment of carpal tunnel syndrome (CTS) remains a challenge for hand surgeons. Carpal tunnel release (CTR) using nasal instruments has the advantages of both endoscopy and open surgery. In this study we aimed to explore the effectiveness of CTR using nasal instruments in Chinese patients.We present a case series of 49 cases of idiopathic CTS treated with the mini-incision technique using nasal instruments. The average recovery days before return to normal work and complications were recorded. The mean grip strength, pinch strength, and sensation were evaluated. Subjective results were evaluated using the visual analogue scale (VAS), Levine Carpal Tunnel Syndrome Questionnaire (LCTSQ), Disabilities of the Arm, Shoulder, and Hand (DASH), and Medical Outcomes Study (MOS) 36-item short-form health survey (SF-36).The mean follow-up was 13 months. No return of symptoms or blood vessel injury occurred. The incidence of scar tenderness was only 8.1%, later pillar pain (after 4 weeks) was 18.4%, and average recovery time to return to normal work was 23.7 days. The mean grip strength, pinch strength, and sensation were significantly improved (P < .001). The VAS, LCTSQ, and DASH survey postoperative mean scores were lower than the preoperative scores (P < .001). SF-36 scores were significantly increased following surgery (P < .001).We conclude that the mini-incision technique for CTR using nasal instruments in Chinese patients is safe, effective, and low cost. It is worthwhile for the technique to be promoted and used.

  10. Ultrasound-guided hydrodissection decreases gliding resistance of the median nerve within the carpal tunnel.

    PubMed

    Evers, Stefanie; Thoreson, Andrew R; Smith, Jay; Zhao, Chunfeng; Geske, Jennifer R; Amadio, Peter C

    2018-01-01

    The aim of this study was to assess alterations in median nerve (MN) biomechanics within the carpal tunnel resulting from ultrasound-guided hydrodissection in a cadaveric model. Twelve fresh frozen human cadaver hands were used. MN gliding resistance was measured at baseline and posthydrodissection, by pulling the nerve proximally and then returning it to the origin. Six specimens were treated with hydrodissection, and 6 were used as controls. In the hydrodissection group there was a significant reduction in mean peak gliding resistance of 92.9 ± 34.8 mN between baseline and immediately posthydrodissection (21.4% ± 10.5%; P = 0.001). No significant reduction between baseline and the second cycle occurred in the control group: 9.6 ± 29.8 mN (0.4% ± 5.3%; P = 0.467). Hydrodissection can decrease the gliding resistance of the MN within the carpal tunnel, at least in wrists unaffected by carpal tunnel syndrome. A clinical trial of hydrodissection seems justified. Muscle Nerve 57: 25-32, 2018. © 2017 Wiley Periodicals, Inc.

  11. Subject-Specific Finite Element Analysis of the Carpal Tunnel Cross-Sectional to Examine Tunnel Area Changes in Response to Carpal Arch Loading

    PubMed Central

    Walia, Piyush; Erdemir, Ahmet; Li, Zong-Ming

    2017-01-01

    Background Manipulating the carpal arch width (i.e. distance between hamate and trapezium bones) has been suggested as a means to increase carpal tunnel cross-sectional area and alleviate median nerve compression. The purpose of this study was to develop a finite element model of the carpal tunnel and to determine an optimal force direction to maximize area. Methods A planar geometric model of carpal bones at hamate level was reconstructed from MRI with inter-carpal joint spaces filled with a linear elastic surrogate tissue. Experimental data with discrete carpal tunnel pressures (50, 100, 150, and 200 mmHg) and corresponding carpal bone movements were used to obtain material property of surrogate tissue by inverse finite element analysis. The resulting model was used to simulate changes of carpal arch widths and areas with directional variations of a unit force applied at the hook of hamate. Findings Inverse finite element model predicted the experimental area data within 1.5% error. Simulation of force applications showed that carpal arch width and area were dependent on the direction of force application, and minimal arch width and maximal area occurred at 138° (i.e. volar-radial direction) with respect to the hamate-to-trapezium axis. At this force direction, the width changed to 24.4 mm from its initial 25.1 mm (3% decrease), and the area changed to 301.6 mm2 from 290.3 mm2 (4% increase). Interpretation The findings of the current study guide biomechanical manipulation to gain tunnel area increase, potentially helping reduce carpal tunnel pressure and relieve symptoms of compression median neuropathy. PMID:28073093

  12. Autologous Fat Transfer in Secondary Carpal Tunnel Release

    PubMed Central

    Noszczyk, Bartłomiej H.

    2015-01-01

    Background: Carpal tunnel release is the gold standard for the treatment of median nerve compression disease. Recurrent or persistent symptoms do not occur in most patients, although a small number of them have indicated that such a postoperative condition indeed exists. Some patients undergo repeated treatments. In the majority of the cases, the disease is associated with scarring in the carpal tunnel or even reformation of the carpal ligament. The authors propose the usage of autologous fat grafting during secondary carpal tunnel release to inhibit the scarring process. Methods: Ten patients with recurrent or persistent symptoms underwent autologous fat grafting at the time of their repeated carpal tunnel release. Fat was harvested from the lower abdomen and grafted into the scarred transverse carpal ligament and surrounding tissues. Each patient underwent pre- and postoperative examinations and completed the carpal tunnel questionnaire (Boston) to evaluate their sensory and motor functions. The patients underwent 1 year of follow-up. Results: There were 2 main reasons for continued symptoms: a technical mistake resulting in incomplete release (IR) during the first operation and abundant scarring (ABS) in the operated area. The beneficial effects of the interventions were confirmed by a clinical study and by administering the carpal tunnel questionnaire to all patients (functional severity score decreased from 4.38 to 1.88 in IR and 3.62 to 1.48 in ABS group, sensory severity score from 3.26 to 1.7 in IR and 3.04 to 1.48 in ABS group; P < 0.05) after 12 months of follow-up. Conclusion: Our initial observations suggest the possible efficacy of adipose tissue in secondary carpal tunnel release. PMID:26090291

  13. Anatomical variations of the carpal tunnel structures

    PubMed Central

    Mitchell, Ryan; Chesney, Amy; Seal, Shane; McKnight, Leslie; Thoma, Achilleas

    2009-01-01

    There are many anatomical variations in and around the carpal tunnel that affect the nerves, tendons and arteries in this area. Awareness of these variations is important both during the clinical examination and during carpal tunnel release. The purpose of the present review is to highlight recognized anatomical variations within the carpal tunnel including variation in nerve anatomy, tendon anatomical variants, vascular anatomical variations and muscle anatomical variations. PMID:20808747

  14. [Effect of zirconia abutment angulation on stress distribution in the abutment and the bone around implant: a finite element study].

    PubMed

    Yang, Yan-zhong; Tian, Xiao-hua; Zhou, Yan-min

    2015-08-01

    To investigate the effect of three different zirconia angular abutments on the stress distribution in bone and abutment using three-dimensional finite element analysis, and provide instruction for clinical application. Finite element analysis (FEA) was applied to analyze the stress distribution of three different zirconia/titanium angular abutments and bone around implant. The maximum Von Minses stress that existed in abutment, bolt and bone of the angular abutment model was significantly higher than that existed in the straight abutment model. The maximum Von Minses stress that existed in abutment, bolt and bone of the 20 ° angular abutment model was significantly higher than that existed in 15 ° angular abutment model. There was no significant difference between zirconia abutment model and titanium abutment model. The abutment angulation has a significant influence on the stress distribution in the abutment, bolt and bone, and exacerbates as the angulation increases, which suggest that we should take more attention to the implant orientation and use straight abutment or little angular abutment. The zirconia abutment can be used safely, and there is no noticeable difference between zirconia abutment and titanium abutment on stress distribution.

  15. The influence of removable partial dentures on the periodontal health of abutment and non-abutment teeth.

    PubMed

    Dula, Linda J; Shala, Kujtim Sh; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F

    2015-01-01

    The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.

  16. Workplace and individual risk factors for carpal tunnel syndrome.

    PubMed

    Burt, Susan; Crombie, Ken; Jin, Yan; Wurzelbacher, Steve; Ramsey, Jessica; Deddens, James

    2011-12-01

    To quantify the relationship between workplace physical factors, particularly hand activity level (HAL) and forceful exertion and carpal tunnel syndrome (CTS), while taking into account individual factors. To compare quantitative exposure assessment measures with more practical ratings-based measures. In a group of healthcare and manufacturing workers, each study participant's job tasks were evaluated for HAL, forceful exertion and other physical stressors and videotaped for further analysis, including frequency and duration of exertion and postural deviation. Electrodiagnostic testing of median and ulnar nerves and questionnaires were administered to all participants. A CTS case required median mononeuropathy and symptoms on hand diagrams in fingers 1-3. Multiple logistic regression models were used to analyse associations between job and individual factors and CTS. Of 477 workers studied, 57 (11.9%) were dominant hand CTS cases. Peak force ≥70% maximum voluntary contraction versus <20% maximum voluntary contraction resulted in an OR of 2.74 (1.32-5.68) for CTS. Among those with a body mass index ≥30, the OR for ≥15 exertions per minute was 3.35 (1.14-9.87). Peak worker ratings of perceived exertion increased the odds for CTS by 1.14 (1.01-1.29) for each unit increase on the 10-point scale. The odds for CTS increased by 1.38 (1.05-1.81) for each unit increase on the HAL 10-point scale among men, but not women. Combined force and HAL values above the ACGIH TLV for HAL resulted in an OR of 2.96 (1.51-5.80) for CTS. Quantitative and ratings-based job exposure measures were each associated with CTS. Obesity increased the association between frequency of exertion and CTS.

  17. The influence of removable partial dentures on the periodontal health of abutment and non-abutment teeth

    PubMed Central

    Dula, Linda J.; Shala, Kujtim Sh.; Pustina–Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.

    2015-01-01

    Objective: The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. Materials and Methods: A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). Results: The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). Conclusions: With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases. PMID:26430367

  18. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    PubMed

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  19. Personal and occupational risk factors for carpal tunnel syndrome in meat processing industry workers in Northern Italy.

    PubMed

    Riccò, Matteo; Signorelli, Carlo

    2017-03-24

    Carpal tunnel syndrome (CTS) is a musculoskeletal condition that often impairs the fitness to work. Our aim is to retrospectively evaluate the association between physical exposures in meat processing industry in Northern Italy and the CTS, taking into account non-occupational factors. A cross-sectional study was performed to include 434 workers (236 males, 198 females, 37.0±10.6 years old, working age: 12.6±10.8 years) from meat processing industries. Signs and symptoms were collected at the compulsory occupational medical surveillance. Occupational risk factors were assessed through a questionnaire and direct assessment by investigators. Adjusted odds ratios (ORadj) for factors of interest were estimated through binary logistic regression. Diagnosis of the CTS was reported for 61 out of 434 subjects (14.1%) for an incidence of 11.3/1000 person- years. In general, signs and symptoms for the CTS were associated with the following demographic factors: smoking history (OR = 1.909, 95% confidence interval (CI): 1.107-3.293), previous traumas of the upper limb (OR = 3.533, 95% CI: 1.743-7.165), hypothyroidism status (OR = 7.897, 95% CI: 2.917-21.38) and, in the case of female participants only, previous pregnancies (OR = 2.807, 95% CI: 1.200-6.566) as well as a personal history of oral contraceptive therapy and/or steroidal replacement therapy (OR = 11.57, 95% CI: 4.689-28.56). The carpal tunnel syndrome cases were associated with the following occupational factors (> 4 h/day): forceful hand exertion (ORadj = 3.548, 95% CI: 1.379-9.131), repeated trauma of the hand (ORadj = 3.602, 95% CI: 1.248- 10.395), repeated movements of the wrist (ORadj = 2.561, 95% CI: 1.100-5.960). Increasing levels of hand activity and force were associated with the increased CTS prevalence among participants. Recommendations have to be provided in order to reduce occupational exposure to these risk factors and improve medical surveillance. Med Pr

  20. Off-road machine controls: investigating the risk of carpal tunnel syndrome.

    PubMed

    Oliver, M; Rickards, J; Biden, E

    2000-11-01

    Occupationally induced hand and wrist repetitive strain injuries (RSI) such as carpal tunnel syndrome (CTS) are a growing problem in North America. The purpose of this investigation was to apply a modification of the wrist flexion/ extension models of Armstrong and Chaffin (1978, 1979) to determine if joystick controller use in off-road machines could contribute to the development of CTS. A construction equipment cab in the laboratory was instrumented to allow force, displacement and angle measurements from 10 operators while they completed an approximately 30-min joystick motion protocol. The investigation revealed that both the external fingertip and predicted internal wrist forces resulting from the use of these joysticks were very low, indicating that the CTS risk associated with this factor was slight. However, the results also indicated that, particularly for the 'forward' and 'left' right side motions and for all left side motions, force was exerted by other portions of the fingers and hand, thereby under-predicting the tendon tension and internal wrist forces. Wrist angles observed were highest for motions that moved the joysticks to the sides rather than front to back. Thus, the 'right' and 'left' motions for both hands posed a higher risk for CTS development. When the right hand moved into the 'right' position and the left hand moved into the 'left' position, the wrist went into extension in both cases. Results indicate that neither learning nor fatigue affected the results.

  1. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    PubMed Central

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material. PMID:25551010

  2. [The contribution made by neurophysiological and ultrasound imaging studies to the diagnosis of carpal tunnel syndrome. Surgical correlation].

    PubMed

    de Pablos, C; Velasco-Zarzosa, M; Landeras-Alvaro, R; Rubio-Lorenzo, M; Martínez-Zubieta, P

    Electrophysiological study has been for long time the elected approach for the diagnosis and clinical evaluation of carpal tunnel syndrome (CTS). More recently, echography and other imaging techniques have been introduced in current medicine for their potential in the anatomical evaluation of the neural compression. To asses the usefulness of both diagnostic procedures we have compared the findings obtained by electrophysiological and echographic approaches in a group of 60 CTS patients with different degrees of the disease. In all patients the conduction velocity was evaluated in the median and cubital nerves using surface electrodes. For echography lineal transductors of 5-10 Hz and 5-12.5 MHz were employed. The patients were distributed for each test on a scale depending of the severity of the alterations detected by the corresponding technique and both files were subsequently compared by regression analysis, Pearson test and paired-test. No correlation was detected in any of the statistical test. The lack of correlation between the results of both proofs emphasizes the usefulness of the two diagnostic approaches in CTS. While electrophysiological study provides information about nerve function, ecography unravels the morphological alterations accounting for the syndrome, therefore being non-excluding complementary approaches.

  3. Endoscopic and Open Release Similarly Safe for the Treatment of Carpal Tunnel Syndrome. A Systematic Review and Meta-Analysis

    PubMed Central

    Vasiliadis, Haris S.; Nikolakopoulou, Adriani; Shrier, Ian; Lunn, Michael P.; Brassington, Ruth; Scholten, Rob J. P.; Salanti, Georgia

    2015-01-01

    Background The Endoscopic Release of Carpal Tunnel Syndrome (ECTR) is a minimal invasive approach for the treatment of Carpal Tunnel Syndrome. There is scepticism regarding the safety of this technique, based on the assumption that this is a rather “blind” procedure and on the high number of severe complications that have been reported in the literature. Purpose To evaluate whether there is evidence supporting a higher risk after ECTR in comparison to the conventional open release. Methods We searched MEDLINE (January 1966 to November 2013), EMBASE (January 1980 to November 2013), the Cochrane Neuromuscular Disease Group Specialized Register (November 2013) and CENTRAL (2013, issue 11 in The Cochrane Library). We hand-searched reference lists of included studies. We included all randomized or quasi-randomized controlled trials (e.g. study using alternation, date of birth, or case record number) that compare any ECTR with any OCTR technique. Safety was assessed by the incidence of major, minor and total number of complications, recurrences, and re-operations.The total time needed before return to work or to return to daily activities was also assessed. We synthesized data using a random-effects meta-analysis in STATA. We conducted a sensitivity analysis for rare events using binomial likelihood. We judged the conclusiveness of meta-analysis calculating the conditional power of meta-analysis. Conclusions ECTR is associated with less time off work or with daily activities. The assessment of major complications, reoperations and recurrence of symptoms does not favor either of the interventions. There is an uncertain advantage of ECTR with respect to total minor complications (more transient paresthesia but fewer skin-related complications). Future studies are unlikely to alter these findings because of the rarity of the outcome. The effect of a learning curve might be responsible for reduced recurrences and reoperations with ECTR in studies that are more recent

  4. Endoscopic and Open Release Similarly Safe for the Treatment of Carpal Tunnel Syndrome. A Systematic Review and Meta-Analysis.

    PubMed

    Vasiliadis, Haris S; Nikolakopoulou, Adriani; Shrier, Ian; Lunn, Michael P; Brassington, Ruth; Scholten, Rob J P; Salanti, Georgia

    2015-01-01

    The Endoscopic Release of Carpal Tunnel Syndrome (ECTR) is a minimal invasive approach for the treatment of Carpal Tunnel Syndrome. There is scepticism regarding the safety of this technique, based on the assumption that this is a rather "blind" procedure and on the high number of severe complications that have been reported in the literature. To evaluate whether there is evidence supporting a higher risk after ECTR in comparison to the conventional open release. We searched MEDLINE (January 1966 to November 2013), EMBASE (January 1980 to November 2013), the Cochrane Neuromuscular Disease Group Specialized Register (November 2013) and CENTRAL (2013, issue 11 in The Cochrane Library). We hand-searched reference lists of included studies. We included all randomized or quasi-randomized controlled trials (e.g. study using alternation, date of birth, or case record number) that compare any ECTR with any OCTR technique. Safety was assessed by the incidence of major, minor and total number of complications, recurrences, and re-operations.The total time needed before return to work or to return to daily activities was also assessed. We synthesized data using a random-effects meta-analysis in STATA. We conducted a sensitivity analysis for rare events using binomial likelihood. We judged the conclusiveness of meta-analysis calculating the conditional power of meta-analysis. ECTR is associated with less time off work or with daily activities. The assessment of major complications, reoperations and recurrence of symptoms does not favor either of the interventions. There is an uncertain advantage of ECTR with respect to total minor complications (more transient paresthesia but fewer skin-related complications). Future studies are unlikely to alter these findings because of the rarity of the outcome. The effect of a learning curve might be responsible for reduced recurrences and reoperations with ECTR in studies that are more recent, although formal statistical analysis failed

  5. Carpal tunnel syndrome: Analysis of online patient information with the EQIP tool.

    PubMed

    Frueh, F S; Palma, A F; Raptis, D A; Graf, C P; Giovanoli, P; Calcagni, M

    2015-06-01

    Patients suffering from carpal tunnel syndrome (CTS) actively search for medical information on the Internet. The World Wide Web represents the main source of patient information. The aim of this study was to systematically assess the quality of patient information about CTS in the Internet. A qualitative and quantitative assessment of websites was performed with the modified Ensuring Quality Information for Patients (EQIP) tool that contains 36 standardized items. Five hundred websites with information on CTS treatment options were identified through Google, Bing, Yahoo, Ask.com and AOL. Duplicates and irrelevant websites were excluded. One hundred and ten websites were included. Only five websites addressed more than 20 items; quality scores were not significantly different between the various providing groups. A median of 15 EQIP items was found, with the top website addressing 26 out of 36 items. Major complications such as median nerve injury were reported in 27% of the websites and their treatment in only 3%. This analysis revealed several critical shortcomings in the quality of the information provided to patients suffering from CTS. There is a collective need to provide interactive, informative and educational websites for standard procedures in hand surgery. These websites should be compatible with international quality standards for hand surgery procedures. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Effects of static fingertip loading on carpal tunnel pressure

    NASA Technical Reports Server (NTRS)

    Rempel, D.; Keir, P. J.; Smutz, W. P.; Hargens, A.

    1997-01-01

    The purpose of this study was to explore the relationship between carpal tunnel pressure and fingertip force during a simple pressing task. Carpal tunnel pressure was measured in 15 healthy volunteers by means of a saline-filled catheter inserted percutaneously into the carpal tunnel of the nondominant hand. The subjects pressed on a load cell with the tip of the index finger and with 0, 6, 9, and 12 N of force. The task was repeated in 10 wrist postures: neutral; 10 and 20 degrees of ulnar deviation; 10 degrees of radial deviation; and 15, 30, and 45 degrees of both flexion and extension. Fingertip loading significantly increased carpal tunnel pressure for all wrist angles (p = 0.0001). Post hoc analyses identified significant increase (p < 0.05) in carpal tunnel pressure between unloaded (0 N) and all loaded conditions, as well as between the 6 and 12 N load conditions. This study demonstrates that the process whereby fingertip loading elevates carpal tunnel pressure is independent of wrist posture and that relatively small fingertip loads have a large effect on carpal tunnel pressure. It also reveals the response characteristics of carpal tunnel pressure to fingertip loading, which is one step in understanding the relationship between sustained grip and pinch activities and the aggravation or development of median neuropathy at the wrist.

  7. The mini-incision technique for carpal tunnel release using nasal instruments in Chinese patients

    PubMed Central

    Chen, Yanhua; Ji, Wei; Li, Tao; Cong, Xiaobin; Chen, Zhenbing

    2017-01-01

    Abstract Treatment of carpal tunnel syndrome (CTS) remains a challenge for hand surgeons. Carpal tunnel release (CTR) using nasal instruments has the advantages of both endoscopy and open surgery. In this study we aimed to explore the effectiveness of CTR using nasal instruments in Chinese patients. We present a case series of 49 cases of idiopathic CTS treated with the mini-incision technique using nasal instruments. The average recovery days before return to normal work and complications were recorded. The mean grip strength, pinch strength, and sensation were evaluated. Subjective results were evaluated using the visual analogue scale (VAS), Levine Carpal Tunnel Syndrome Questionnaire (LCTSQ), Disabilities of the Arm, Shoulder, and Hand (DASH), and Medical Outcomes Study (MOS) 36-item short-form health survey (SF-36). The mean follow-up was 13 months. No return of symptoms or blood vessel injury occurred. The incidence of scar tenderness was only 8.1%, later pillar pain (after 4 weeks) was 18.4%, and average recovery time to return to normal work was 23.7 days. The mean grip strength, pinch strength, and sensation were significantly improved (P < .001). The VAS, LCTSQ, and DASH survey postoperative mean scores were lower than the preoperative scores (P < .001). SF-36 scores were significantly increased following surgery (P < .001). We conclude that the mini-incision technique for CTR using nasal instruments in Chinese patients is safe, effective, and low cost. It is worthwhile for the technique to be promoted and used. PMID:28767593

  8. [Etiological factors for developing carpal tunnel syndrome in people who work with computers].

    PubMed

    Lewańska, Magdalena; Wagrowska-Koski, Ewa; Walusiak-Skorupa, Jolanta

    2013-01-01

    Carpal tunnel syndrome (CTS) is the most frequent mononeuropathy of upper extremities. From the early 1990's it has been suggested that intensive work with computers can result in CTS development, however, this relationship has not as yet been proved. The aim of the study was to evaluate occupational and non-occupational risk factors for developing CTS in the population of computer-users. The study group comprised 60 patients (58 women and 2 men; mean age: 53.8 +/- 6.35 years) working with computers and suspected of occupational CTS. A survey as well as both median and ulnar nerve conduction examination (NCS) were performed in all the subjects. The patients worked with use of computer for 6.43 +/- 1.71 h per day. The mean latency between the beginning of employment and the occurrence of first CTS symptoms was 12.09 +/- 5.94 years. All patients met the clinical and electrophysiological diagnostic criteria of CTS. In the majority of patients etiological factors for developing CTS were non-occupational: obesity, hypothyroidism, oophorectomy, past hysterectomy, hormonal replacement therapy or oral contraceptives, recent menopause, diabetes, tendovaginitis. In 7 computer-users etiological factors were not identified. The results of our study show that CTS is usually generated by different causes not related with using computers at work.

  9. Failure modes of Y-TZP abutments with external hex implant-abutment connection determined by fractographic analysis.

    PubMed

    Basílio, Mariana de Almeida; Delben, Juliana Aparecida; Cesar, Paulo Francisco; Rizkalla, Amin Sami; Santos Junior, Gildo Coelho; Arioli Filho, João Neudenir

    2016-07-01

    Yttria-stabilized tetragonal zirconia (Y-TZP) was introduced as ceramic implant abutments due to its excellent mechanical properties. However, the damage patterns for Y-TZP abutments are limited in the literature. Fractographic analyses can provide insights as to the failure origin and related mechanisms. The purpose of this study was to analyze fractured Y-TZP abutments to establish fractographic patterns and then possible reasons for failure. Thirty two prefabricated Y-TZP abutments on external hex implants were retrieved from a single-load-to failure test according to the ISO 14801. Fractographic analyses were conducted under polarized-light estereo and scanning electro microscopy. The predominant fracture pattern was abutment fracture at the connecting region. Classic fractographic features such as arrest lines, hackle, and twist hackle established that failure started where Y-TZP abutments were in contact with the retention screw edges. The abutment screw design and the loading point were the reasons for localized stress concentration and fracture patterns. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Incidence of carpal tunnel syndrome in the US military population.

    PubMed

    Wolf, Jennifer Moriatis; Mountcastle, Sally; Owens, Brett D

    2009-09-01

    Carpal tunnel syndrome (CTS) is a common disease. Its epidemiology has been evaluated previously, mostly in regional populations or in working groups, with an incidence between 1.5 and 3.5 per 1,000 person-years. We studied this diagnosis in the US military population, with the hypothesis that this young population would have a lower incidence of CTS than previously reported in general populations. The Defense Medical Epidemiology Database notes all medical encounters for all US military personnel and maintains the number of all personnel on active duty each year. We queried the database using the International Classification of Diseases, ninth revision, code 354.0 (CTS) and analyzed the personnel presenting for initial visits for the years 1998-2006. Multivariate Poisson analysis was performed, controlling for rank, gender, age, and race. The raw incidence of CTS in the US military was 3.98 per 1,000 person-years, in a population of 12,298,088 person-years. Females had a significantly higher incidence of CTS than males, with an adjusted incidence rate ratio of 3.29. CTS incidence increased by age, with the age group > or = 40 years having a significantly higher incidence. Additionally, military rank was found to be an independent risk factor for CTS, with rates higher in senior officer and enlisted groups. This suggests that occupational requirements have an effect on CTS within the military. We showed a comparable incidence of CTS between the US military and general population, with a significantly higher female cohort with a diagnosis of CTS. Increased age and advanced rank were risk factors for CTS.

  11. Somatosensory cortical plasticity in carpal tunnel syndrome treated by acupuncture.

    PubMed

    Napadow, Vitaly; Liu, Jing; Li, Ming; Kettner, Norman; Ryan, Angela; Kwong, Kenneth K; Hui, Kathleen K S; Audette, Joseph F

    2007-03-01

    Carpal tunnel syndrome (CTS) is a common entrapment neuropathy of the median nerve characterized by paresthesias and pain in the first through fourth digits. We hypothesize that aberrant afferent input from CTS will lead to maladaptive cortical plasticity, which may be corrected by appropriate therapy. Functional MRI (fMRI) scanning and clinical testing was performed on CTS patients at baseline and after 5 weeks of acupuncture treatment. As a control, healthy adults were also tested 5 weeks apart. During fMRI, sensory stimulation was performed for median nerve innervated digit 2 (D2) and digit 3 (D3), and ulnar nerve innervated digit 5 (D5). Surface-based and region of interest (ROI)-based analyses demonstrated that while the extent of fMRI activity in contralateral Brodmann Area 1 (BA 1) and BA 4 was increased in CTS compared to healthy adults, after acupuncture there was a significant decrease in contralateral BA 1 (P < 0.005) and BA 4 (P < 0.05) activity during D3 sensory stimulation. Healthy adults demonstrated no significant test-retest differences for any digit tested. While D3/D2 separation was contracted or blurred in CTS patients compared to healthy adults, the D2 SI representation shifted laterally after acupuncture treatment, leading to increased D3/D2 separation. Increasing D3/D2 separation correlated with decreasing paresthesias in CTS patients (P < 0.05). As CTS-induced paresthesias constitute diffuse, synchronized, multidigit symptomatology, our results for maladaptive change and correction are consistent with Hebbian plasticity mechanisms. Acupuncture, a somatosensory conditioning stimulus, shows promise in inducing beneficial cortical plasticity manifested by more focused digital representations. (c) 2006 Wiley-Liss, Inc.

  12. The Influence of Torque Tightening on the Position Stability of the Abutment in Conical Implant-Abutment Connections.

    PubMed

    Hogg, Wiebke Semper; Zulauf, Kris; Mehrhof, Jürgen; Nelson, Katja

    2015-01-01

    The influence of repeated system-specific torque tightening on the position stability of the abutment after de- and reassembly of the implant components was evaluated in six dental implant systems with a conical implant-abutment connection. An established experimental setup was used in this study. Rotation, vertical displacement, and canting moments of the abutment were observed; they depended on the implant system (P = .001, P < .001, P = .006, respectively). Repeated torque tightening of the abutment screw does not eliminate changes in position of the abutment.

  13. Endoscopic carpal tunnel release using the modified Chow's extrabursal dual portal technique: clinical results of 640 patients.

    PubMed

    Kim, Poong-Taek; Micić, Ivan D; Park, Il-Hyng; Jeon, In-ho

    2007-01-01

    During a 4-year period, a total of 784 wrists of 640 patients were treated using a modified Chow's extrabursal dual portal endoscopic technique. All surgeries were performed under local anesthesia. A 1-cm incision was marked 1-2 cm proximal to the distal wrist crease, in the midline, ulnar to the palmaris longus. A distal portal was established along a line bisecting an angle created by the intersection of the ulnar border of the abducted thumb and the third web space. An obturator and cannula assembly were inserted under the portal, and three blades were used to cut under endoscopic vision. Subjective results showed that 706 hands (90%) had a reduction in the severity of pain after carpal tunnel release, 706 hands (90%) had a reduction in the severity of paresthesia and 729 hands (93%) had a reduction in the severity of numbness. Nocturnal pain and paresthesia were relieved in 745 cases (95%). Compared with the conventional open carpal tunnel release, less postoperative pain and faster recovery have been reported following endoscopic carpal tunnel release. This study suggests that extrabursal dual portal technique is a safe and reliable treatment option for carpal tunnel syndrome with a high success rate.

  14. Pooling job physical exposure data from multiple independent studies in a consortium study of carpal tunnel syndrome

    PubMed Central

    Kapellusch, Jay M.; Garg, Arun; Bao, Stephen S.; Silverstein, Barbara A.; Burt, Susan E.; Dale, Ann Marie; Evanoff, Bradley A.; Gerr, Frederic E.; Harris-Adamson, Carisa; Hegmann, Kurt T.; Merlino, Linda A.; Rempel, David M.

    2015-01-01

    Pooling data from different epidemiological studies of musculoskeletal disorders (MSDs) is necessary to improve statistical power and to more precisely quantify exposure–response relationships for MSDs. The pooling process is difficult and time-consuming, and small methodological differences could lead to different exposure–response relationships. A subcommittee of a six-study research consortium studying carpal tunnel syndrome: (i) visited each study site, (ii) documented methods used to collect physical exposure data and (iii) determined compatibility of exposure variables across studies. Certain measures of force, frequency of exertion and duty cycle were collected by all studies and were largely compatible. A portion of studies had detailed data to investigate simultaneous combinations of force, frequency and duration of exertions. Limited compatibility was found for hand/wrist posture. Only two studies could calculate compatible Strain Index scores, but Threshold Limit Value for Hand Activity Level could be determined for all studies. Challenges of pooling data, resources required and recommendations for future researchers are discussed. PMID:23697792

  15. One-year incidence of carpal tunnel syndrome in Latino poultry processing workers and other Latino manual workers.

    PubMed

    Cartwright, Michael S; Walker, Francis O; Newman, Jill C; Schulz, Mark R; Arcury, Thomas A; Grzywacz, Joseph G; Mora, Dana C; Chen, Haiying; Eaton, Bethany; Quandt, Sara A

    2014-03-01

    To determine the incidence of carpal tunnel syndrome (CTS) over 1 year in Latino poultry processing workers. Symptoms and nerve conduction studies were used to identify Latino poultry processing workers (106 wrists) and Latinos in other manual labor occupations (257 wrists) that did not have CTS at baseline, and these individuals were then evaluated in the same manner 1 year later. Based on wrists, the 1-year incidence of CTS was higher in poultry processing workers than non-poultry manual workers (19.8% vs. 11.7%, P = 0.022). Poultry workers had a higher odds (1.89; P = 0.089) of developing CTS over 1 year compared to non-poultry manual workers. Latino poultry processing workers have an incidence of CTS that is possibly higher than Latinos in other manual labor positions. Latino poultry workers' high absolute and relative risk of CTS likely results from the repetitive and strenuous nature of poultry processing work. © 2013 Wiley Periodicals, Inc.

  16. Feasibility of a Novel Functional Sensibility Test as an Assisted Examination for Determining Precision Pinch Performance in Patients with Carpal Tunnel Syndrome

    PubMed Central

    Hsu, Hsiu-Yun; Kuo, Li-Chieh; Kuo, Yao-Lung; Chiu, Haw-Yen; Jou, I-Ming; Wu, Po-Ting; Su, Fong-Chin

    2013-01-01

    To understand the feasibility of a novel functional sensibility test for determining precision pinch performance in patients with carpal tunnel syndrome, this study investigates the validity, sensitivity and specificity of functional sensibility derived from a pinch-holding-up activity (PHUA) test. Participants include 70 clinically defined carpal tunnel syndrome (CTS) patients with 119 involved hands and 70 age- and gender-matched controls. To examine the discriminating ability of the functional sensibility test, the differences in the ability of pinch force adjustments to the inertial load of handling object between CTS and control subjects are analyzed. The results of functional sensibility are correlated with the severity of CTS to establish concurrent validity. The receiver operating characteristic (ROC) curve is constructed to demonstrate the accuracy of the proposed test. The functional sensibility score significantly discriminates the patients and control groups (respectively, 12.94±1.72 vs. 11.51±1.15N in peak pinch force (FPPeak), p<0.001; 2.92±0.41 vs. 2.52±0.24 in force ratio, p<0.001) and is moderately correlated (r = 0.42–0.54, p<0.001) with the results of traditional sensibility tests (touch-pressure threshold and two-point discrimination test). In addition, there is a statistical difference in the results of functional sensibility (p<0.001) among the subgroups of CTS severity based on electrophysiological study. The sensitivity and specificity are 0.79 and 0.76, respectively, for the functional sensibility test. The areas under the ROC curve are 0.85 and 0.80 for the force ratio and FPPeak, respectively. In conclusion, the functional sensibility test could be feasibly used as a clinical tool for determining both the sensibility and precision pinch performance of hands for the patients with CTS. PMID:23977209

  17. Reliability and construct validity of the Spanish version of the 6-item CTS symptoms scale for outcomes assessment in carpal tunnel syndrome.

    PubMed

    Rosales, Roberto S; Martin-Hidalgo, Yolanda; Reboso-Morales, Luis; Atroshi, Isam

    2016-03-03

    The purpose of this study was to assess the reliability and construct validity of the Spanish version of the 6-item carpal tunnel syndrome (CTS) symptoms scale (CTS-6). In this cross-sectional study 40 patients diagnosed with CTS based on clinical and neurophysiologic criteria, completed the standard Spanish versions of the CTS-6 and the disabilities of the arm, shoulder and hand (QuickDASH) scales on two occasions with a 1-week interval. Internal-consistency reliability was assessed with the Cronbach alpha coefficient and test-retest reliability with the intraclass correlation coefficient, two way random effect model and absolute agreement definition (ICC2,1). Cross-sectional precision was analyzed with the Standard Error of the Measurement (SEM). Longitudinal precision for test-retest reliability coefficient was assessed with the Standard Error of the Measurement difference (SEMdiff) and the Minimal Detectable Change at 95 % confidence level (MDC95). For assessing construct validity it was hypothesized that the CTS-6 would have a strong positive correlation with the QuickDASH, analyzed with the Pearson correlation coefficient (r). The standard Spanish version of the CTS-6 presented a Cronbach alpha of 0.81 with a SEM of 0.3. Test-retest reliability showed an ICC of 0.85 with a SRMdiff of 0.36 and a MDC95 of 0.7. The correlation between CTS-6 and the QuickDASH was concordant with the a priori formulated construct hypothesis (r 0.69) CONCLUSIONS: The standard Spanish version of the 6-item CTS symptoms scale showed good internal consistency, test-retest reliability and construct validity for outcomes assessment in CTS. The CTS-6 will be useful to clinicians and researchers in Spanish speaking parts of the world. The use of standardized outcome measures across countries also will facilitate comparison of research results in carpal tunnel syndrome.

  18. Activation in the hypothalamic-pituitary-adrenocortical axis and sympathetic nervous system in women with carpal tunnel syndrome.

    PubMed

    Fernández-de-Las-Peñas, César; Díaz-Rodríguez, Lourdes; Salom-Moreno, Jaime; Galiano-Castillo, Noelia; Valverde-Herreros, Lis; Martínez-Martín, Javier; Pareja, Juan A

    2014-08-01

    The aim of this study is to investigate the differences in salivary cortisol (hypothalamic-pituitary-adrenocortical [HPA] axis), α-amylase activity (sympathetic nervous system [SNS]), and immunoglobulin A (IgA; immune system) concentrations between women with carpal tunnel syndrome (CTS) and healthy women. A cross-sectional study. Activation of HPA, SNS, and immune system in CTS has not been clearly determined. One hundred two women (age: 45 ± 7 years) with electrodiagnostic and clinical diagnosis of CTS and 102 matched healthy women. The intensity of the pain was assessed with a Numerical Pain Rating Scale (0-10), and disability was determined with Boston Carpal Tunnel Questionnaire. Salivary cortisol concentration, α-amylase activity, salivary flow rate, and IgA concentration were collected from nonstimulated saliva. Women with CTS exhibited lower salivary flow rate (P < 0.001) and higher α-amylase activity (P < 0.01) than controls. No significant differences for cortisol and IgA concentrations (P > 0.2) were found between groups as a total. Women with severe CTS exhibited lower salivary flow rate (P < 0.001), higher α-amylase activity (P = 0.002), and higher cortisol concentration (P = 0.03) than healthy women and than those with minimal/moderate CTS (P < 0.05). Within women with CTS, significant positive associations between α-amylase activity and the intensity of pain were found: the highest the level of pain, the higher the α-amylase activity, i.e., higher SNS activation. These results suggest that women with severe CTS exhibit changes in activation in the HPA axis and SNS but not in the humoral immune system. Activation of the SNS was associated with the intensity of pain. Future studies are needed to elucidate the direction of this relationship. Wiley Periodicals, Inc.

  19. Comparative Analysis of Screw Loosening With Prefabricated Abutments and Customized CAD/CAM Abutments.

    PubMed

    Paek, Janghyun; Woo, Yi-Hyung; Kim, Hyeong-Seob; Pae, Ahran; Noh, Kwantae; Lee, Hyeonjong; Kwon, Kung-Rock

    2016-12-01

    The aim of this study was to determine the stability of computer-aided design and manufacturing (CAD/CAM) and prefabricated abutment by measuring removal torque before and after cyclic loading. Three types of fixture and 2 types of abutments were used. Removable torque was measured after cyclic loading for 5000 cycles between 25 and 250 N for each group. The same procedure was performed twice. First, removal torque values (Newton centimeter) were measured for stock versus custom abutments as follows: group 1: 27.17 versus 26.67, group 2: 26.27 versus 26.33, and group 3: 37.33 versus 36.67. Second removal torque values (Newton centimeter) were also measured: group 1: 23 versus 23.5, group 2: 22.5 versus 22.33, and group 3: 32.67 versus 32.5. There was no significant difference between the stock and custom abutments in either the first or second removal torque values and also no significant difference among initial tightening torque, first or second removal torque (P > 0.05). With precise control of CAD/CAM abutments, good screw joint stability can be achieved.

  20. Support Ratio Between Abutment and Soft Tissue Under Overdentures: A Comparison Between Use of Two and Four Abutments.

    PubMed

    Abe, Manami; Yang, Tsung-Chieh; Maeda, Yoshionobu; Ando, Takanori; Wada, Masahiro

    The purpose of this preliminary in vivo study was to compare force distribution on abutments (tooth or implant) and tissues supporting overdentures with two or four abutments. A convenience sample of five subjects with tooth and/or implant-supported overdentures was enrolled. Recordings were completed on each subject using a force-measuring system mounted on a metal framework with four anteroposterior spread abutments (A), four abutments with denture bases (B), and on two anterior abutments with denture bases (C). The tissue-support ratio (TSR) was calculated as (A-B)/A or (A-C)/A. TSR values changed 1.5 to 2 times when the number of abutments was reduced from four to two. The amount of tissue strain on the posterior residual ridge increased when the number of abutments was reduced.

  1. Microbiological and clinical assessment of the abutment and non-abutment teeth of partial removable denture wearers.

    PubMed

    Costa, Luciana; do Nascimento, Cássio; de Souza, Valéria Oliveira Pagnano; Pedrazzi, Vinícius

    2017-03-01

    The aim of this study was assessing the changes in both clinical and microbiological parameters of healthy individuals after rehabilitation with removable partial denture (RPD). 11 women received unilateral or bilateral free-end saddle RPD in the mandibular arch. Clinical and microbiological parameters of abutment, non-abutment, and antagonist teeth were assessed at baseline (RPD installation) and after 7, 30, 90, and 180days of function. The Checkerboard DNA-DNA hybridization technique was used to identify and quantify up to 43 different microbial species from subgingival biofilm samples. Probing depth, gingival recession, and bleeding on probing were also investigated over time. The total and individual microbial genome counts were shown significantly increased after 180days with no significant differences between abutment, non-abutment, or antagonist teeth. Streptococcus spp., Aggregatibacter actinomycetemcomitans, and other species associated to periodontitis (Peptostreptococcus anaerobius, Prevotella nigrescens, and Tannerella forsythia), as well as opportunistic Candida spp., were recovered in moderate counts. Abutment teeth presented higher values of gingival recession when compared with non-abutment or antagonist teeth, irrespectively time of sampling (p<0.05). No significant differences were found between groups regarding bleeding on probing or probing depth over time. Overall, the microbial counts significantly increased after 6 months of denture loading for both abutment and non-abutment teeth with no significant differences regarding the microbial profile over time. Bleeding on probing and probing depth showed no significant difference between groups over time whereas gingival recession increased in the abutment teeth. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Carpal tunnel syndrome and prediabetes: is there a true association?

    PubMed

    Sousa Vasconcelos, José Tupinambá; Freitas Paiva, Ângela Maria; Cavalcanti, Mauro Furtado; de Carvalho, Jozélio Freire; Bonfá, Eloisa; Borba, Eduardo Ferreira

    2015-10-01

    Carpal tunnel syndrome (CTS) is probably associated with diabetes mellitus, but its link to prediabetes (PD) is unknown. To determine prevalence of PD and others risk factors in CTS. A cross-sectional study including 115 idiopathic CTS patients and 115 age-, gender-and body mass index (BMI)-matched controls was performed. Clinical, laboratory and neurophysiological evaluations were conducted in all subjects to confirm CTS diagnosis. CTS severity was graded on a standardized neurophysiological scale. PD was defined using strict criteria. The prevalence of PD was similar in CTS and control groups (27% vs. 21.7%, respectively P=0.44). Nocturnal symptoms (91.3%) and moderate CTS (58.3%) were most frequently observed in CTS patients. In logistic regression analysis, PD was significantly correlated with age (odds ratio [OR] 1.05, 95% confidence interval [CI] 1.01-1.09; P=0.006) and BMI (OR 1.08. 95% CI 1.01-1.16; P=0.026), but not with CTS (OR 0.82, 95% CI 0.43-1.53; P=0.537). CTS patients with PD had a significantly higher mean age compared to those without PD (53.8±10.2 vs. 49.5±8.6 years, respectively P=0.027). The frequency of age >60 years was significantly higher in CTS with PD than in CTS without PD (29.0% vs. 8.3%, respectively P=0.04) as was BMI >30kg/m(2) (64.5% vs. 33.3%, respectively P=0.03). No significant differences were observed between the two CTS groups with respect to gender, BMI, symptoms, and neurophysiological severity of CTS. Our findings indicated that CTS is not associated with PD, but that PD is closely linked to age and overweight. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Computer use and carpal tunnel syndrome: A meta-analysis.

    PubMed

    Shiri, Rahman; Falah-Hassani, Kobra

    2015-02-15

    Studies have reported contradictory results on the role of keyboard or mouse use in carpal tunnel syndrome (CTS). This meta-analysis aimed to assess whether computer use causes CTS. Literature searches were conducted in several databases until May 2014. Twelve studies qualified for a random-effects meta-analysis. Heterogeneity and publication bias were assessed. In a meta-analysis of six studies (N=4964) that compared computer workers with the general population or other occupational populations, computer/typewriter use (pooled odds ratio (OR)=0.72, 95% confidence interval (CI) 0.58-0.90), computer/typewriter use ≥1 vs. <1h/day (OR=0.63, 95% CI 0.38-1.04) and computer/typewriter use ≥4 vs. <4h/day (OR=0.68, 95% CI 0.54-0.87) were inversely associated with CTS. Conversely, in a meta-analysis of six studies (N=5202) conducted among office workers, CTS was positively associated with computer/typewriter use (pooled OR=1.34, 95% CI 1.08-1.65), mouse use (OR=1.93, 95% CI 1.43-2.61), frequent computer use (OR=1.89, 95% CI 1.15-3.09), frequent mouse use (OR=1.84, 95% CI 1.18-2.87) and with years of computer work (OR=1.92, 95% CI 1.17-3.17 for long vs. short). There was no evidence of publication bias for both types of studies. Studies that compared computer workers with the general population or several occupational groups did not control their estimates for occupational risk factors. Thus, office workers with no or little computer use are a more appropriate comparison group than the general population or several occupational groups. This meta-analysis suggests that excessive computer use, particularly mouse usage might be a minor occupational risk factor for CTS. Further prospective studies among office workers with objectively assessed keyboard and mouse use, and CTS symptoms or signs confirmed by a nerve conduction study are needed. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Accessory carpal bone luxation in two gray wolves (Canis lupus).

    PubMed

    Keller, Dominique L; Ellison, Michelle; Clyde, Victoria L; Wallace, Roberta S

    2012-09-01

    Two sibling male castrated gray wolves (Canis lupus) developed acute onset right forelimb lameness, one at 8 and the other at 11 yr of age. In both cases, the right carpus was swollen, carpal hyperextension was notable, and the wolves exhibited significant intermittent lameness of the affected limb. Radiographs revealed right accessory carpal bone luxation in both cases, with type III fracture of the accessory carpal bone in one wolf. Although carpal bone luxation in domestic dogs is frequently treated surgically, conservative medical management resolved the lameness in both wolves with no further complications.

  5. Comparison of evoked potentials in the same hand in normal subjects and in patients with carpal tunnel syndrome.

    PubMed

    Felsenthal, G

    1978-10-01

    The amplitude of the evoked median and ulnar sensory action potential (SAP) was measured in fifty normal volunteers (4) and median and ulnar SAP in opposite hands were compared. In addition, the amplitude of the median response was compared to the ulnar response. It was found that the lower limit of the range of observations for the median amplitude was 20 muV, the range of observations for the median/median SAP ratio was 50--100%, and that in only 3 observations out of 100 normal hands was the median/ulnar SAP ratio less than 80%. In a series of 60 patients with carpal tunnel syndrome (CTS), 22 had bilateral involvement. The median SAP was obtainable in 62 of these diagnosed cases of CTS. Forty of these 62 cases could be identified by one of the three amplitude criteria: median SAP of less than 20 muV; median/median amplitude percentage of less than 50%; or a median/ulnar amplitude of less than 80%.

  6. The effectiveness of the low-power laser and kinesiotaping in the treatment of carpal tunnel syndrome, a pilot study.

    PubMed

    Güner, A; Altan, L; Kasapoğlu Aksoy, M

    2018-05-01

    In mild and moderate cases of carpal tunnel syndrome (CTS), the conservative approach is suggested. The purpose of this study is to assess and compare the effect of low-power laser versus the combination of low-power laser and kinesiotaping on pain, muscle strength, functionality, and electrophysiologic parameters in the patients with CTS. The study was planned as single-blind, prospective, randomized control. 64 hands diagnosed with CTS were included in the study. The patients were randomly divided into three groups by closed envelope method. Low-power laser therapy was applied to Group 1 (21 hands), kinesiotaping and low-power laser therapy in group 2 (22 hands), sham laser therapy in Group 3 (21 hands). All patients were assessed by visual numeric pain scale (VNS), hand grip strength (HGS), finger pinch strength (FPS), the Boston Carpal Tunnel Syndrome Questionnaire (BCTSQ), before treatment, after treatment (3rd week), and after (12th week) 3 months the treatment with the same physician. Motor and sensory nerve conduction studies were performed with electroneuromyography (ENMG) before the treatment (0th week) and at the end of the 12th week. Comparison of the group 1 with the group 3 showed significantly better improvement in the former in VNS, BCTSQ at 3rd week and 12th week compared to 0th week, and in FPS and HGS at 3rd week. Comparison of the group 2 with the group 3 showed significantly better improvement in the former VNS, BCTSQ, FPS and HGS at 3rd and 12th week compared to 0th week. When Group 1 and Group 2 were compared there was no statistically significant difference in any parameters in the 3rd week, but there was a statistically significant difference in favor of group 2 in FPS and HGS parameters at the 12th week. We have found that the kinesiotaping method applied with low-power laser treatment does not provide any additional benefit to the low-power laser treatment in the short term, however, in the long term, the increase in the HGS and FPS has

  7. The efficiency of acoustic radiation force impulse (ARFI) elastography in the diagnosis and staging of carpal tunnel syndrome.

    PubMed

    Arslan, Harun; Yavuz, Alpaslan; İlgen, Ferda; Aycan, Abdurrahman; Ozgokce, Mesut; Akdeniz, Hüseyin; Batur, Abdussamet

    2018-01-12

    The aim of the present study was to quantify the stiffness of the median nerve (MN) at the carpal tunnel inlet by acoustic radiation force impulse (ARFI) elastography and to evaluate whether ARFI can be used in diagnosis and staging of carpal tunnel syndrome (CTS). Sonographic examinations of 96 wrists in 50 patients were included in the study. The cross-sectional area and stiffness of the MN were quantitatively measured by B-mode ultrasonography (USG) and ARFI. The findings of CTS were assigned to four groups: (I) normal (n = 21), (II) mild (n = 39), (III) moderate (n = 38), and (IV) severe (n = 19). The differences between CTS patients and controls and the differences in electrodiagnostic tests among subgroups were statistically compared. ROC analysis was performed to determine the cut-off values between subgroups. Bilateral CTS was present in 46 patients (92 wrists) and unilateral CTS in four patients. Of the 96 nerves in the 50 symptomatic "idiopathic CTS" patients (48 women, 2 men; mean age 45.9 years, range 23-73 years), 39 (40.4%) were mild, 38 (39.8%) were moderate, and 19 (19.8%) were severely affected. When compared to controls, MN stiffness was significantly higher in the CTS group (P < 0.001); furthermore, it was higher in the severe or extreme severity group than the mild or moderate severity group (P < 0.001). A 3.250 m/s cut-off value on ARFI revealed sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 81, 82, 95.1, 50, and 82%, respectively. The MN stiffness measured by ARFI elastography is significantly higher in patients with CTS then in controls. ARFI elastography appears to be a highly efficient imaging modality for the diagnosis and staging of these patients.

  8. Wear at the Implant-Abutment Interface of Zirconia Abutments Manufactured by Three CAD/CAM Systems.

    PubMed

    Pinheiro Tannure, Ana Luiza; Cunha, Alfredo Gonçalves; Borges Junior, Luiz Antônio; da Silva Concílio, Laís Regiane; Claro Neves, Ana Christina

    To evaluate the changes in the external-hexagon surface of the titanium (Ti) implant before and after mechanical cycling, when coupled with zirconia (Zr) abutments (A) manufactured by three computer-aided design/computer-aided manufacturing (CAD/CAM) systems (Neodent Digital, Zirkonzahn, and AmannGirrbach) and the ZrTi abutment manufactured by Neodent. Four groups were formed (n = 6): titanium implant with Zr AmannGirrbach abutment (AZrAG), with Zr Zirkonzahn abutment (AZrZ), with Zr Neodent abutment (AZrN), and with Zr abutment with infrastructure in Ti Neodent (AZrTiN). Standardized abutments were made from three identical abutments milled in wax. Images of the surface of each side of the hexagons of the implant were obtained by scanning electron microscopy, before and after mechanical cycling, to evaluate the parameters: (1) scratches in the hexagon face; (2) hexagon superior shoulder kneading; (3) hexagon shoulder wear; (4) alterations on the hexagon base; and (5) scratches on the hexagon top. The abutments were coupled with the implants, and Cr-Co crowns were cemented. The implant/abutment/crown assemblies were submitted to mechanical cycling (400 N, 8.0 Hz) for 1 million cycles. The observed changes were classified as follows: absence (0), mild (1), moderate (2), and severe (3). The results were analyzed using the Mann-Whitney, Kruskal-Wallis, and Dunn tests (P < .05). For parameter 1, a significant difference (P = .008) was observed between AZrZ and AZrAG, with more scratches in AZrZ; and between AZrN and AZrTiN (P = .006), with more scratches in AZrN. For parameter 2, a significant difference (P < .05) was observed between AZrZ and AZrAG and between AZrZ and AZrN, with greater kneading in AZrZ; among AZrN and AZrTiN, there was no significant difference (P = .103). For parameter 3, a significant difference (P < .05) was observed between AZrZ and the other groups of Zr, with more wear in AZrZ; between AZrN and AZrTiN, there was no significant difference (P

  9. Settling of abutments into implants and changes in removal torque in five different implant-abutment connections. Part 1: Cyclic loading.

    PubMed

    Kim, Ki-Seong; Han, Jung-Suk; Lim, Young-Jun

    2014-01-01

    The aim of this study was to evaluate and compare the settling of abutments into implants and the removal torque values (RTVs) before and after cyclic loading. Five different implant-abutment connections were tested: Ext = external butt joint + two-piece abutment; Int-H2 = internal hexagon + two-piece abutment; Int-H1 = internal hexagon + one-piece abutment; Int-O2 = internal octagon + two-piece abutment; and Int-O1 = internal octagon + one-piece abutment. Ten abutments from each group were secured to their corresponding implants (total n = 50). All samples were tested in a universal testing machine with a vertical load of 250 N for 100,000 cycles of 14 Hz. The amount of settling of the abutment into the implant was calculated from the change in the total length of the implant-abutment sample before and after loading, as measured with an electronic digital micrometer. The RTV after cyclic loading was compared to the initial RTV with a digital torque gauge. Statistical analysis was performed at a 5% significance level. A multiple-comparison test showed specific significant differences in settling values in each group after 250 N cyclic loading (Int-H1, Ext < Int-H2 < Int-O2 < Int-O1). There were statistically significant decreases in RTVs after loading compared to the initial RTVs in the Int-H2 and Int-O2 groups. No statistically significant differences were found in the Ext, Int-H1, and Int-O1 groups. The results of this study demonstrated that the settling amount and RTV (loss of preload) after cyclic loading were specific to the abutment type and related to the design characteristics of the implant-abutment connection.

  10. Efficacy of Combined Ultrasound-Guided Steroid Injection and Splinting in Patients With Carpal Tunnel Syndrome: A Randomized Controlled Trial.

    PubMed

    Wang, Jia-Chi; Liao, Kwong-Kum; Lin, Kon-Ping; Chou, Chen-Liang; Yang, Tsui-Fen; Huang, Yu-Fang; Wang, Kevin A; Chiu, Jan-Wei

    2017-05-01

    To compare the effectiveness of local steroid injection plus splinting with that of local steroid injection alone using clinical and electrophysiological parameters in patients with carpal tunnel syndrome (CTS). Randomized controlled study with 12 weeks of follow-up. Tertiary care center. Volunteer sample of patients (N=52) diagnosed with CTS. Participants were randomly assigned to the steroid injection group (n=26) or the steroid injection-plus-splinting group (n=26). Patients of both groups received ultrasound-guided steroid injection with 1mL of 10mg (10mg/mL) triamcinolone acetonide (Shincort) and 1mL of 2% lidocaine hydrochloride (Xylocaine). Participants in the second group also wore a volar splint in the neutral position while sleeping and also during daytime whenever possible for the 12-week intervention period. Participants were evaluated before the treatment and at 6 and 12 weeks after the onset of treatment. The primary outcome measure was Boston Carpal Tunnel Questionnaire scores. The secondary outcome measures were as follows: scores on the visual analog scale for pain; electrophysiological parameters, including median nerve distal motor latency, sensory nerve conduction velocity (SNCV), and compound muscle action potential and sensory nerve action potential (SNAP) amplitudes; and patient's subjective impression of improvement. At 12-week follow-up, improvements in symptom severity and functional status scores on the Boston Carpal Tunnel Questionnaire as well as SNCV and SNAP amplitudes were greater in the group that received steroid injection combined with splinting than in the group that received steroid injection alone. The between-group difference was .48 points (95% confidence interval [CI], .09-.88 points; P=.032) in the Symptom Severity Scale score, .37 points (95% CI, .06-.67 points; P=.019) in the Functional Status Scale score, 3.38m/s (95% CI, 0.54-6.22m/s; P=.015) in the SNCV amplitude, and 3.21μV (95% CI, 0.00-6.46μV; P=.025) in the SNAP

  11. Carpal tunnel volume changes of the wrist under distraction.

    PubMed

    Cho, M S; Means, K R; Shrout, J A; Segalman, K A

    2008-10-01

    This study attempts to determine changes in carpal canal volume with distraction across the wrist. Uniform longitudinal distraction was maintained with two external fixators on the radial and ulnar aspects of the forearm axis of five cadaver specimens. After CT scanning, volume determinations were made at 5 mm increments beginning at the lunocapitate joint to a point 1.5 cm distal to the middle finger carpometacarpal joint. There was a statistically significant decrease of the mean total carpal canal volume from 0 to 4.54 kg of distraction, with no statistically significant decrease from 0 to 2.27 kg or 2.27 to 4.54 kg. The largest decrease occurred at 15 and 20 mm distal to the proximal edge of the transverse carpal ligament corresponding to the level of the hamate hook. Reduction in mean carpal canal volume was 10.2% and 7.5% at these distances, respectively, from 0 to 4.54 kg of distraction. Progressive distraction across the wrist causes a decrease in total carpal canal volume.

  12. A prospective study of carpal tunnel syndrome: workplace and individual risk factors.

    PubMed

    Burt, Susan; Deddens, James A; Crombie, Ken; Jin, Yan; Wurzelbacher, Steve; Ramsey, Jessica

    2013-08-01

    To quantify the risk for carpal tunnel syndrome (CTS) from workplace physical factors, particularly hand activity level and forceful exertion, while taking into account individual factors including age, gender, body mass index (BMI), and pre-existing medical conditions. Three healthcare and manufacturing workplaces were selected for inclusion on the basis of range of exposure to hand activity level and forceful exertion represented by their jobs. Each study participant's job tasks were observed and evaluated onsite and videotaped for further analysis, including frequency and duration of exertion and postural deviation. Individual health assessment entailed electrodiagnostic testing of median and ulnar nerves, physical examination and questionnaires at baseline with annual follow-up for 2 years. The incidence of dominant hand CTS during the study was 5.11 per 100 person-years (29 cases). Adjusted HRs for dominant hand CTS were as follows: working with forceful exertion ≥ 20% but <60% of the time: 2.83 (1.18, 6.79) and ≥ 60% of the time vs <20%: 19.57 (5.96, 64.24), BMI ≥ 30 kg/m(2) (obesity): 3.19 (1.28, 7.98). The American Conference for Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) for hand activity level also predicted CTS, HR=1.40 (1.11, 1.78) for each unit increase in the TLV ratio, controlling for obesity and job strain. Workplace and individual risk factors both contribute to the risk for CTS. Time spent in forceful exertion can be a greater risk for CTS than obesity if the job exposure is high. Preventive workplace efforts should target forceful exertions.

  13. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept.

    PubMed

    Sailer, Irena; Asgeirsson, Asgeir G; Thoma, Daniel S; Fehmer, Vincent; Aspelund, Thor; Özcan, Mutlu; Pjetursson, Bjarni E

    2018-04-01

    There is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. To compare the fracture strength of narrow diameter abutments with different types of implant abutment connections after chewing simulation. Hundred and twenty identical customized abutments with different materials and implant abutment connections were fabricated for five groups: 1-piece zirconia abutment with internal connection (T1, Cares-abutment-Straumann BL-NC implant, Straumann Switzerland), 1-piece zirconia abutment with external hex connection (T2, Procera abutment-Branemark NP implant, Nobel Biocare, Sweden), 2-piece zirconia abutments with metallic insert for internal connection (T3, Procera abutment-Replace NP implant, Nobel Biocare), 2-piece zirconia abutment on titanium resin base (T4, LavaPlus abutment-VarioBase-Straumann BL-NC implant, 3M ESPE, Germany) and 1-piece titanium abutment with internal connection (C, Cares-abutment-Straumann BL-NC implant, Straumann, Switzerland). All implants had a narrow diameter ranging from 3.3 to 3.5 mm. Sixty un-restored abutments and 60 abutments restored with glass-ceramic crowns were tested. Mean bending moments were compared using ANOVA with p-values adjusted for multiple comparisons using Tukey's procedure. The mean bending moments were 521 ± 33 Ncm (T4), 404 ± 36 Ncm (C), 311 ± 106 Ncm (T1) 265 ± 22 Ncm (T3) and 225 ± 29 (T2) for un-restored abutments and 278 ± 84 Ncm (T4), 302 ± 170 Ncm (C), 190 ± 55 Ncm (T1) 80 ± 102 Ncm (T3) and 125 ± 57 (T2) for restored abutments. For un-restored abutments, C and T4 had similar mean bending moments, significantly higher than those of the three other groups (p < .05). Titanium abutments (C) had significantly higher bending moments than identical zirconia abutments (T1) (p < .05). Zirconia

  14. The comparison between limited open carpal tunnel release using direct vision and tunneling technique and standard open carpal tunnel release: a randomized controlled trial study.

    PubMed

    Suppaphol, Sorasak; Worathanarat, Patarawan; Kawinwongkovit, Viroj; Pittayawutwinit, Preecha

    2012-04-01

    To compare the operative outcome of carpal tunnel release between limited open carpal tunnel release using direct vision and tunneling technique (group A) with standard open carpal tunnel release (group B). Twenty-eight patients were enrolled in the present study. A single blind randomized control trial study was conducted to compare the postoperative results between group A and B. The study parameters were Levine's symptom severity and functional score, grip and pinch strength, and average two-point discrimination. The postoperative results between two groups were comparable with no statistical significance. Only grip strength at three months follow up was significantly greater in group A than in group B. The limited open carpal tunnel release in the present study is effective comparable to the standard open carpal tunnel release. The others advantage of this technique are better cosmesis and improvement in grip strength at the three months postoperative period.

  15. Score Reliability and Construct Validity of the Flinn Performance Screening Tool for Adults With Symptoms of Carpal Tunnel Syndrome

    PubMed Central

    Flinn, Sharon R.; Pease, William S.; Freimer, Miriam L.

    2013-01-01

    OBJECTIVE We investigated the psychometric properties of the Flinn Performance Screening Tool (FPST) for people referred with symptoms of carpal tunnel syndrome (CTS). METHOD An occupational therapist collected data from 46 participants who completed the Functional Status Scale (FSS) and FPST after the participants’ nerve conduction velocity study to test convergent and contrasted-group validity. RESULTS Seventy-four percent of the participants had abnormal nerve conduction studies. Cronbach’s α coefficients for subscale and total scores of the FPST ranged from .96 to .98. Intrarater reliability for six shared items of the FSS and the FPST was supported by high agreement (71%) and a fair κ statistic (.36). Strong to moderate positive relationships were found between the FSS and FPST scores. Functional status differed significantly among severe, mild, and negative CTS severity groups. CONCLUSION The FPST shows adequate psychometric properties as a client-centered screening tool for occupational performance of people referred for symptoms of CTS. PMID:22549598

  16. Prevalence, incidence and risk factors of carpal tunnel syndrome in a large footwear factory.

    PubMed

    Roquelaure, Y; Mariel, J; Dano, C; Fanello, S; Penneau-Fontbonne, D

    2001-01-01

    The study was conducted to assess the prevalence and incidence of carpal tunnel syndrome (CTS) in a large modern footwear factory and to identify factors predictive of CTS. To this end, 199 workers were examined in 1996, and 162 of them were re-examined in 1997. Ergonomic and psychosocial risk factors of CTS were assessed by workpost analysis and self-administered questionnaire. The prevalence of CTS at baseline in 1996 and in 1997 was 16.6% (95%CI: 11.4-21.7) and 11.7% (95%CI: 6.7-16.8), respectively. The incidence rate of CTS in 1997 was 11.7% (95%CI: 6.7-7.8). No specific type of job performance was associated with CTS. Obesity (OR = 4.4; 95%CI: 1.1-17.1) and psychological distress at baseline (OR = 4.3; 95%CI: 1.0-18.6) were strongly predictive of CTS. Rapid trigger movements of the fingers were also predictive of CTS (OR = 3.8; 95%CI: 1.0-17.2). A strict control of thework by superiors was negatively associatedwith CTS (OR = 0.5; 95%CI: 0.2-1.3). The prevalence and incidence of CTS in this workforce were largely higher than in the general population and numerous industries. The study highlights the role of psychological distress in workers exposed to a high level of physical exposure and psychological demand.

  17. Pre-surgery Disability Compensation Predicts Long-Term Disability among Workers with Carpal Tunnel Syndrome

    PubMed Central

    Spector, June T.; Turner, Judith A.; Fulton-Kehoe, Deborah; Franklin, Gary

    2012-01-01

    Background We sought to identify early risk factors for work disability compensation prior to and after carpal tunnel syndrome (CTS) surgery, and to determine whether pre-surgery disability compensation is associated with long-term disability. Methods Washington State workers’ compensation administrative data and data from interviews with workers 18 days (median) after submitting new workers’ compensation claims for CTS were examined. Baseline risk factors for pre-surgery disability compensation and for long-term disability (≥365 days of work disability compensation prior to two years after claim filing) were evaluated for workers who underwent CTS surgery and had at least one day of disability compensation (N=670). Results After adjustment for baseline long-term disability risk factors, workers with pre-surgery disability compensation had over five times the odds of long-term disability. Baseline factors in multiple domains, including job, psychosocial, clinical, and worker pain and function, were associated with both pre-surgery disability compensation and long-term disability. Conclusions Risk factors for work disability prior to and after CTS surgery are similar, and early work disability is a risk factor for long-term CTS-related disability. An integrated approach to CTS-related disability prevention could include identifying and addressing combined risk factors soon after claim filing, more efficient use of conservative treatments and appropriate work modifications to minimize early work loss, and, when indicated, timely surgical intervention. PMID:22392804

  18. Bilateral simultaneous endoscopic carpal tunnel release: Mean time to resume activities of daily living and return to work.

    PubMed

    Degeorge, B; Coulomb, R; Kouyoumdjian, P; Mares, O

    2018-06-01

    The purpose of this study was to determine the time needed to return to personal and professional activities after bilateral simultaneous endoscopic carpal tunnel release. During a retrospective, single-center study, we included a cohort of 30 patients (60 wrists). Patients were evaluated clinically (pain, paresthesia) and functionally (QuickDASH score) pre- and postoperatively. At the last follow-up, patients completed a questionnaire regarding the time needed to resume personal activities using the ADL scale (feeding, personal hygiene and dressing) and return to work. We also evaluated procedure satisfaction and willingness to undergo the surgery again. The average patient age was 60.5 years (range 39-86). At the last follow-up, average time to resume personal activities was 2.2 days (0-14) for feeding, 4.4 days (0-15) for personal hygiene and 3.9 days (0-14) for dressing. Average time to return to recreational activities was 11.7 days (1-60). Average time to return to work was 36.6 days (15-60). Overall, 97% of patients were satisfied or very satisfied with the outcome. All patients would have the bilateral simultaneous surgery again. Bilateral simultaneous endoscopic carpal tunnel release is rarely performed. For mild conditions, contralateral symptom improvement is common after unilateral surgery. Bilateral simultaneous endoscopic carpal tunnel release appears to be disabling right after surgery, but clinical and functional scores are similar after the third postoperative day. These data can be used for patient education and decision making when considering surgery bilateral carpal tunnel syndrome. Bilateral simultaneous endoscopic carpal tunnel release is a feasible and safe procedure. Level IV, case series. Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  19. Physicochemical and microscopic characterization of implant–abutment joints

    PubMed Central

    Lopes, Patricia A.; Carreiro, Adriana F. P.; Nascimento, Rubens M.; Vahey, Brendan R.; Henriques, Bruno; Souza, Júlio C. M.

    2018-01-01

    Objective: The purpose of this study was to investigate Morse taper implant–abutment joints by chemical, mechanical, and microscopic analysis. Materials and Methods: Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant–abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant–abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant–abutment joints. Statistics: Results were statistically analyzed via one-way analysis of variance, with a significance level of P < 0.05. Results: Defects were noticed on different areas of the abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant–abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Conclusions: Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant–abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication. PMID:29657532

  20. Physicochemical and microscopic characterization of implant-abutment joints.

    PubMed

    Lopes, Patricia A; Carreiro, Adriana F P; Nascimento, Rubens M; Vahey, Brendan R; Henriques, Bruno; Souza, Júlio C M

    2018-01-01

    The purpose of this study was to investigate Morse taper implant-abutment joints by chemical, mechanical, and microscopic analysis. Surfaces of 10 Morse taper implants and the correlated abutments were inspected by field emission gun-scanning electron microscopy (FEG-SEM) before connection. The implant-abutment connections were tightened at 32 Ncm. For microgap evaluation by FEG-SEM, the systems were embedded in epoxy resin and cross-sectioned at a perpendicular plane of the implant-abutment joint. Furthermore, nanoindentation tests and chemical analysis were performed at the implant-abutment joints. Results were statistically analyzed via one-way analysis of variance, with a significance level of P < 0.05. Defects were noticed on different areas of the abutment surfaces. The minimum and maximum size of microgaps ranged from 0.5 μm up to 5.6 μm. Furthermore, defects were detected throughout the implant-abutment joint that can, ultimately, affect the microgap size after connection. Nanoindentation tests revealed a higher hardness (4.2 ± 0.4 GPa) for abutment composed of Ti6Al4V alloy when compared to implant composed of commercially pure Grade 4 titanium (3.2 ± 0.4 GPa). Surface defects produced during the machining of both implants and abutments can increase the size of microgaps and promote a misfit of implant-abutment joints. In addition, the mismatch in mechanical properties between abutment and implant can promote the wear of surfaces, affecting the size of microgaps and consequently the performance of the joints during mastication.

  1. Global point signature for shape analysis of carpal bones

    NASA Astrophysics Data System (ADS)

    Chaudhari, Abhijit J.; Leahy, Richard M.; Wise, Barton L.; Lane, Nancy E.; Badawi, Ramsey D.; Joshi, Anand A.

    2014-02-01

    We present a method based on spectral theory for the shape analysis of carpal bones of the human wrist. We represent the cortical surface of the carpal bone in a coordinate system based on the eigensystem of the two-dimensional Helmholtz equation. We employ a metric—global point signature (GPS)—that exploits the scale and isometric invariance of eigenfunctions to quantify overall bone shape. We use a fast finite-element-method to compute the GPS metric. We capitalize upon the properties of GPS representation—such as stability, a standard Euclidean (ℓ2) metric definition, and invariance to scaling, translation and rotation—to perform shape analysis of the carpal bones of ten women and ten men from a publicly-available database. We demonstrate the utility of the proposed GPS representation to provide a means for comparing shapes of the carpal bones across populations.

  2. Mechanical properties of resin glass fiber-reinforced abutment in comparison to titanium abutment

    PubMed Central

    Andreasi Bassi, Mirko; Bedini, Rossella; Pecci, Raffella; Ioppolo, Pietro; Lauritano, Dorina; Carinci, Francesco

    2015-01-01

    Purpose: So far, definitive implant abutments have been performed with high elastic modulus materials, which prevented any type of shock absorption of the chewing loads and as a consequence, the protection of the bone-fixture interface. This is particularly the case when the esthetic restorative material chosen is ceramic rather than composite resin. The adoption of an anisotropic abutment, characterized by an elastic deformability, could allow decreasing the impulse of chewing forces transmitted to the crestal bone. Materials and Methods: According to research protocol, the mechanical resistance to cyclical load was evaluated in a tooth-colored fiber-reinforced abutment (TCFRA) prototype and compared to that of a titanium abutment (TA), thus eight TCFRAs and eight TAs were adhesively cemented on as many titanium implants. The swinging that the two types of abutments showed during the application of sinusoidal load was also analyzed. Results: In the TA group, both fracture and deformation occurred in 12.5% of samples while debonding 62.5%. In the TCFRA group, only debonding was present in 37.5% of samples. In comparison to the TAs, the TCFRAs exhibited a greater swinging during the application of sinusoidal load. In the TA group, the extrusion prevailed, whereas in the TCFRA group, the intrusion was more frequent. Conclusion: The greater elasticity of TCFRA to the flexural load allows absorbing part of the transversal load applied on the fixture during the chewing function, thus reducing the stress on the bone-implant interface. PMID:26229266

  3. Experiences with preventing carpal tunnel syndrome in an automotive plant.

    PubMed

    Žídková, Věra; Nakládalová, Marie; Zapletalová, Jana; Nakládal, Zdeněk; Kollárová, Helena

    2017-02-21

    Carpal tunnel syndrome (CTS) is a common occupational disease. The aim was to assess the effect of preventive measures in automotive assembly workers. The analysis summarizes data from annual crosssectional studies. The 7-year analysis of data was based on medical records obtained from an occupational physician and inspections carried out at the workplace where targeted preventive measures were introduced, including better ergonomic arrangement of the workplace, technical adjustments facilitating the work, preventive nerve conduction studies (NCS) testing of the median nerve once a year, switching of workers and their targeted rotation within the workplace. The NCS testing of median nerve conduction at the wrist was the basic objective method for assessment of the prevalence and severity of CTS. Over the study period, the sample comprised 1804 workers at risk for repetitive overuse of the upper extremities, of whom 281 were females with a mean age of 38.5 years and 1523 were males with a mean age of 31.4 years. Over the study period, a total of 13 cases of CTS were recognized as an occupational disease in the plant, 8 of which occurred within the first 2 years from the initiation of production. Introduction of preventive measures decreased the prevalence of median neuropathy from 18.3% of examined extremities in 2011 to 10.5% in 2013 (p = 0.003). In early 2014, the production pace increased and this was accompanied by a rise in abnormal NCS findings to 16.9%. Over the study period, the rate of sensorimotor neuropathy decreased in favor of merely sensory neuropathies, which have been most frequent since 2013. The percentage of employees whose contracts were terminated due to median neuropathy decreased steadily from 5.5% to 0.4%. Targeted prevention of work-related CTS is effective as evidenced by the decrease in the prevalence of median neuropathy detected by NCS. Int J Occup Med Environ Health 2017;30(1):45-54. This work is available in Open Access model and

  4. Carpal bone movements in gripping action of the giant panda (Ailuropoda melanoleuca)

    PubMed Central

    ENDO, HIDEKI; SASAKI, MOTOKI; HAYASHI, YOSHIHIRO; KOIE, HIROSHI; YAMAYA, YOSHIKI; KIMURA, JUNPEI

    2001-01-01

    The movement of the carpal bones in gripping was clarified in the giant panda (Ailuropoda melanoleuca) by means of macroscopic anatomy, computed tomography (CT) and related 3-dimensional (3-D) volume rendering techniques. In the gripping action, 3-D CT images demonstrated that the radial and 4th carpal bones largely rotate or flex to the radial and ulnar sides respectively. This indicates that these carpal bones on both sides enable the panda to flex the palm from the forearm and to grasp objects by the manipulation mechanism that includes the radial sesamoid. In the macroscopic observations, we found that the smooth articulation surfaces are enlarged between the radial carpal and the radius on the radial side, and between the 4th and ulnar carpals on the ulnar side. The panda skilfully grasps using a double pincer-like apparatus with the huge radial sesamoid and accessory carpal. PMID:11273049

  5. Carpal tunnel biopsy

    MedlinePlus

    ... Updated by: C. Benjamin Ma, MD, Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, CA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team. Amyloidosis Read more Biopsy Read more Carpal Tunnel ...

  6. Carpal tunnel syndrome and work organisation in repetitive work: a cross sectional study in France. Study Group on Repetitive Work

    PubMed Central

    Leclerc, A.; Franchi, P.; Cristofari, M. F.; Delemotte, B.; Mereau, P.; Teyssier-Cotte, C.; Touranchet, A.

    1998-01-01

    OBJECTIVES: To study the determinants of signs of carpal tunnel syndrome (CTS) in repetitive industrial work, with special attention to occupational constraints at group level and management practices of the companies. METHOD: A cross sectional study was conducted in three sectors: assembly line; clothing and shoe industry; food industry. A total of 1210 workers in repetitive work, from 53 different companies, was compared with a control group of 337 workers. Constraints at the workplace were partly self declared, and partly assessed by the occupational physicians in charge of the employees of the company. The definition of CTS was based on a standardised clinical examination. RESULTS: CTS was associated with repetitive work, especially packaging. It was more frequent among subjects who declared psychological and psychosomatic problems and those with a body mass index > or = 27. Dissatisfaction with work, lack of job control, short cycle time, and having to press repeatedly with the hand were associated with the syndrome. An odds ratio (OR) of 2.24 was found for "just in time" production. CONCLUSION: The results emphasise the complexity of the determinants of CTS, the role of psychosocial factors at work and the potentially negative effects of some practices of the companies aimed at enhancing their competitiveness.   PMID:9624269

  7. Use of a splint following open carpal tunnel release: a comparative study.

    PubMed

    Cebesoy, Oguz; Kose, Kamil Cagri; Kuru, Ilhami; Altinel, Levent; Gul, Rauf; Demirtas, Mehmet

    2007-01-01

    This study was undertaken to compare the clinical effectiveness and costs of postoperative splintage and late rehabilitation with a bulky bandage dressing versus early rehabilitation after carpal tunnel release. In this comparative study, 46 patients were randomly divided into 2 groups. In each group, 3 patients were excluded because of improper follow-up, leaving a total of 40 patients. Group 1 used a splint (exercises given 3 wk postoperatively) and group 2 was given a bulky bandage (exercises provided immediately) after open release. Patients were assessed preoperatively and at the first and third postoperative months with the Questionnaire of Levine for Clinical Assessment of Carpal Tunnel Syndrome. The 2 groups were similar in terms of preoperative functional status scores and in controls at the first and third months (P=.549, P=.326, P=.190). When both groups were compared, no statistical significance was found regarding symptom severity scale scores preoperatively and at the first postoperative month (P=.632 vs P=.353). At the third month, scores were lower in favor of group 2 (P=.023). Additionally, 16 of 20 patients (80%) in group 1 reported a heavy feeling and discomfort caused by the splint. This problem was not reported by the patients in group 2. The cheapest splint on the market was 9 times more expensive than a bulky dressing. The investigators concluded that postoperative immobilization with a splint has no detectable benefits. Use of bulky dressings and abandonment of the use of postoperative splints may prevent unnecessary expenditures without sacrificing patient comfort or compromising the course of healing in carpal tunnel surgery.

  8. Time course and predictors of median nerve conduction after carpal tunnel release.

    PubMed

    Rotman, Mitchell B; Enkvetchakul, Bobby V; Megerian, J Thomas; Gozani, Shai N

    2004-05-01

    To identify predictors of outcome and of electrophysiologic recovery in patients with carpal tunnel syndrome (CTS) treated by endoscopic carpal tunnel release using a nerve conduction testing system (NC-Stat; NEUROMetrix, Inc, Waltham, MA). Validity of the automated nerve conduction testing system was shown by comparing presurgical distal motor latencies (DMLs) against a reference obtained by referral to an electromyography laboratory. The DML was evaluated in 48 patients with CTS. Measurements were obtained within 1 hour of surgery and at 2 weeks, 6 weeks, 3 months, and 6 months after carpal tunnel release. Presurgical and postsurgical DMLs were then compared and correlated with variables and possible predictors of outcome including age, body mass index, gender, and presurgical DMLs. The automated nerve conduction testing system DMLs matched those of reference electromyography/nerve conduction study values with high correlation. Sensitivity of the automated nerve conduction testing system when compared with a standardized CTS case definition was 89%, with a specificity of 95%. A significant correlation was found between the DML before release and the DML 1 hour after release. Moreover, maximal postsurgical DML improvement was highly dependent on the presurgical DML, with no improvement shown for the <4-ms group, mild improvement for the 4-to-6-ms group, and maximal improvement in the >6-ms group. Among the clinical variables of age, gender, and body mass index only age was mildly predictive of postrelease DML changes at 6 months. No other correlations between clinical variables and postsurgical DMLs were significant. In addition the predictive value of age was lost when combined with the presurgical DML in a multivariate analysis. Postsurgical changes in the median nerve DML were highly dependent on the prerelease latency. The sensitivity and specificity of a nerve conduction monitoring system in detecting and aiding in the diagnosis of CTS is useful in the long

  9. Displacement of Implant Abutments Following Initial and Repeated Torqueing.

    PubMed

    Yilmaz, Burak; Gilbert, Andy B; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L

    2015-01-01

    To measure and compare the three-dimensional (3D) position of nine different abutments manufactured by different manufacturers after repeated torqueing on an internal-hexagon implant. Nine tapered implants were placed into an acrylic resin block. Five specimens each of nine different abutments (n = 45) were placed into one of nine implants. The abutments were handtightened and then torqued to the manufacturer-recommended torque of 30 Ncm. After 10 minutes, 30 Ncm of torque was reapplied. Another 10 minutes elapsed before testing was completed. Images were recorded in 12-second intervals. The spatial relationship of the abutments to the resin block was determined using 3D digital image correlation. Commercial image correlation software was used to analyze the displacements. Mean displacements for the abutments were calculated in three dimensions and overall for both torque applications. Statistical comparisons were done with a t test and a step-down Bonferroni correction. The overall 3D displacement of the Atlantis Titanium abutment after the second applied torque was significantly greater than that of two of the eight other abutments. Displacement in all three dimensions for the Atlantis Titanium abutment changed direction between the first and second torque applications. All abutments moved further in the same direction except for the Atlantis Titanium abutment, which moved back toward its original hand-tightened position horizontally after the second torque application. Re-torqueing of abutments after a 10-minute interval leads to minor displacement of varying degrees between the abutment and a tapered implant. A potential effect of embedment relaxation and/or manufacturing errors should be taken into consideration when selecting an abutment for a cement-retained crown on a tapered implant. Accordingly, clinicians may benefit from adjusting cement-retained implant crowns after re-torqueing the abutments to prevent potential occlusal and interproximal contact

  10. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns.

    PubMed

    Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves

    2014-02-01

    The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p < 0.05, Fisher's exact test). Group ZiC (21.9 ± 2.68) exhibited significantly lower torque maintenance than groups GC, GR, and TiR (p < 0.05, Fisher's exact test). After mechanical cycling, there was a statistically significant difference between groups TiC (22.1 ± 1.86) and GR (23.8 ± 1.56); between groups ZiC (21.7 ± 2.02) and GR; and also between groups ZiC and TiR (23.6 ± 1.30) (p < 0.05, Fisher's exact test). Detorque reduction occurred regardless of abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established. © 2013 by the American College of Prosthodontists.

  11. Comparing the effectiveness of ultrasound-guided versus blind steroid injection in the treatment of severe carpal tunnel syndrome

    PubMed

    Karaahmet, Özgür Zeliha; Gürçay, Eda; Kara, Murat; Serçe, Azize; Kıraç Ünal, Zeynep; Çakcı, Aytül

    2017-12-19

    Background/aim: This study aimed to compare the effectiveness of ultrasound (US)-guided injection versus blind injection of corticosteroids in the treatment of carpal tunnel syndrome (CTS). Materials and methods: This prospective, randomized clinical trial included patients with severe CTS based on clinical and electrophysiological criteria. The patients were evaluated for clinical and electrophysiological parameters at baseline and 4 weeks after treatment. Symptom severity and hand function were assessed by the Boston questionnaire. The patients underwent blind injection or US-guided injection. Results: When compared with baseline, both groups showed significant improvement in Boston questionnaire scores and all electrophysiological parameters. Significant differences were observed between the groups for clinical parameters (Boston Symptom Severity Scale: P = 0.007; Functional Status Scale: P < 0.001) in favor of the US-guided group. Conclusion: This study demonstrated that both US-guided and blind injections were effective in reducing symptoms and improving hand function. US-guided injections may yield more effective clinical results in the short-term than blind injections in the treatment of patients with severe CTS.

  12. A prospective study of carpal tunnel syndrome: workplace and individual risk factors

    PubMed Central

    Burt, Susan; Deddens, James A; Crombie, Ken; Jin, Yan; Wurzelbacher, Steve; Ramsey, Jessica

    2015-01-01

    Objectives To quantify the risk for carpal tunnel syndrome (CTS) from workplace physical factors, particularly hand activity level and forceful exertion, while taking into account individual factors including age, gender, body mass index (BMI), and pre-existing medical conditions. Methods Three healthcare and manufacturing workplaces were selected for inclusion on the basis of range of exposure to hand activity level and forceful exertion represented by their jobs. Each study participants job tasks were observed and evaluated ’ onsite and videotaped for further analysis, including frequency and duration of exertion and postural deviation. Individual health assessment entailed electrodiagnostic testing of median and ulnar nerves, physical examination and questionnaires at baseline with annual follow-up for 2 years. Results The incidence of dominant hand CTS during the study was 5.11 per 100 person-years (29 cases). Adjusted HRs for dominant hand CTS were as follows: working with forceful exertion ≥20% but <60% of the time: 2.83 (1.18, 6.79) and ≥60% of the time vs <20%: 19.57 (5.96, 64.24), BMI ≥30 kg/m2 (obesity): 3.19 (1.28, 7.98). The American Conference for Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) for hand activity level also predicted CTS, HR=1.40 (1.11, 1.78) for each unit increase in the TLV ratio, controlling for obesity and job strain. Conclusions Workplace and individual risk factors both contribute to the risk for CTS. Time spent in forceful exertion can be a greater risk for CTS than obesity if the job exposure is high. Preventive workplace efforts should target forceful exertions. PMID:23788614

  13. Triggering of Carpal Tunnel Syndrome Symptoms in Patients Using Urban Public Transportation.

    PubMed

    de Saboya Lenzi, Luiz Guilherme; Fernandes, Carlos Henrique; Myiamoto Meirelles, Lia; Baptista Gomes Dos Santos, João; Faloppa, Flávio; Raduan Neto, Jorge

    2016-09-01

    Background: Carpal tunnel syndrome (CTS) is the most common compressive neuropathy found in clinical practice. Recent studies evaluated which external factors could be involved in the CTS symptoms, including prolonged exposure to vibration, especially in the upper limb. This study investigated signs and symptoms in patients with CTS after using urban transport on (1) both upper limbs, (2) how long before these symptoms appear, and (3) the hands position or body reaction during the act of pressing the safety bars. Methods: The study was conducted from July 2012 to April 2013. A total of 205 (178 women and 27 men) patients were evaluated. CTS was diagnosed in 285 hands. All participants answered a questionnaire formulated by the authors. The questionnaire was applied by researchers who were single-blinded and not involved in the research. Results: Most of the participants (87%) were women, but there was no statistical significance in age between groups (women = 51.24 ± 8.47 years, men = 51.10 ± 6.52 years, P > .05). The symptoms appeared significantly in the first 15 minutes after boarding when compared with patients who had no symptoms during the journey. There was no difference between hands position along the journey and the onset of symptoms. Conclusions: The onset of symptoms in patients with CTS using urban public transportation most commonly occurred in the first 15 minutes after boarding. Public transport vibration seems to be, at least in part, directly related to the development of symptoms. Questionnaires for the assessment of paresthesia symptoms during the use of public transport may be useful for CTS diagnosis.

  14. Triggering of Carpal Tunnel Syndrome Symptoms in Patients Using Urban Public Transportation

    PubMed Central

    de Saboya Lenzi, Luiz Guilherme; Fernandes, Carlos Henrique; Myiamoto Meirelles, Lia; Baptista Gomes dos Santos, João; Faloppa, Flávio; Raduan Neto, Jorge

    2016-01-01

    Background: Carpal tunnel syndrome (CTS) is the most common compressive neuropathy found in clinical practice. Recent studies evaluated which external factors could be involved in the CTS symptoms, including prolonged exposure to vibration, especially in the upper limb. This study investigated signs and symptoms in patients with CTS after using urban transport on (1) both upper limbs, (2) how long before these symptoms appear, and (3) the hands position or body reaction during the act of pressing the safety bars. Methods: The study was conducted from July 2012 to April 2013. A total of 205 (178 women and 27 men) patients were evaluated. CTS was diagnosed in 285 hands. All participants answered a questionnaire formulated by the authors. The questionnaire was applied by researchers who were single-blinded and not involved in the research. Results: Most of the participants (87%) were women, but there was no statistical significance in age between groups (women = 51.24 ± 8.47 years, men = 51.10 ± 6.52 years, P > .05). The symptoms appeared significantly in the first 15 minutes after boarding when compared with patients who had no symptoms during the journey. There was no difference between hands position along the journey and the onset of symptoms. Conclusions: The onset of symptoms in patients with CTS using urban public transportation most commonly occurred in the first 15 minutes after boarding. Public transport vibration seems to be, at least in part, directly related to the development of symptoms. Questionnaires for the assessment of paresthesia symptoms during the use of public transport may be useful for CTS diagnosis. PMID:27698625

  15. Dorsal Arthroscopic Approach and Intra-Articular Anatomy of the Bovine Antebrachiocarpal and Middle Carpal Joints.

    PubMed

    Lardé, Hélène; Nichols, Sylvain; Babkine, Marie; Desrochers, André

    2016-07-01

    To determine arthroscopic approaches to the dorsal synovial compartments of the antebrachiocarpal and middle carpal joints in adult cattle, and to describe the arthroscopic intra-articular anatomy from each approach. Ex vivo study. Six fresh adult bovine cadavers. Two carpi were injected with latex and dissected to determine the ideal location for arthroscopic portals. Arthroscopy of the antebrachiocarpal and middle carpal joints of 10 carpi was then performed. The dorsolateral approach was made between the extensor carpi radialis and common digital extensor tendons. The dorsomedial approach was made medial to the extensor carpi radialis tendon, midway between the distal radius and proximal row of carpal bones (antebrachiocarpal joint) and midway between the two rows of carpal bones (middle carpal joint), with the joint in flexion. Arthroscopy of the antebrachiocarpal joint allowed visualization of the distal radius, proximal aspect of the radial, intermediate and ulnar carpal bones, and a palmar ligament located between the radius and the intermediate carpal bone. The approach to the middle carpal joint allowed visualization of the distal aspect of the radial, intermediate, and ulnar carpal bones, the proximal aspect of the fourth and fused second and third carpal bones and an interosseous ligament. The most lateral articular structures (lateral glenoid cavity of the distal radius, ulnar carpal and fourth carpal bones) were difficult to assess. Dorsal approaches to the antebrachiocarpal and middle carpal joints allowed visualization of most intra-articular dorsal structures in adult cattle. © Copyright 2016 by The American College of Veterinary Surgeons.

  16. Does Ferrule Effect Affect Implant-Abutment Stability?

    PubMed

    Mohajerfar, Maryam; Beyabanaki, Elaheh; Geramy, Allahyar; Siadat, Hakimeh; Alikhasi, Marzieh

    2016-12-01

    This study investigated the influence of placing implant-supported crowns on the torque loss of the abutment screw before and after loading. Twenty implant-abutment assemblies were randomly assigned to two groups. The first group was consisted of abutments with abutment-level finishing line (abutment-level), and in the second group the crown margin was placed on the implant shoulder (implant-level). Initial torque loss was recorded for all specimens. After 500000 cyclic load of 75 N and frequency of 2 Hz, post loading torque loss was recorded. Finite element model of each group was also modeled and screw energy, and stress were analyzed and compared between two groups. ANOVA for repeated measurements showed that the torque loss did not change significantly after cyclic loading (P=0.73). Crown margin also had no significant effect on the torque loss (P=0.56). However, the energy and stress of screw in abutment-level model (4.49 mJ and 22.74 MPa) was higher than implant-level model (3.52 mJ and 20.81 MPa). Although embracing the implant with crown produced less stress and energy in the abutment-implant screw, it did not have any significant influence on the torque loss of the screw. Copyright© 2016 Dennis Barber Ltd

  17. Assessing the Value of High-Quality Care for Work-Associated Carpal Tunnel Syndrome in a Large Integrated Health Care System: Study Design.

    PubMed

    Conlon, Craig; Asch, Steven; Hanson, Mark; Avins, Andrew; Levitan, Barbara; Roth, Carol; Robbins, Michael; Dworsky, Michael; Seabury, Seth; Nuckols, Teryl

    2016-01-01

    Little is known about quality of care for occupational health disorders, although it may affect worker health and workers' compensation costs. Carpal tunnel syndrome (CTS) is a common work-associated condition that causes substantial disability. To describe the design of a study that is assessing quality of care for work-associated CTS and associations with clinical outcomes and costs. Prospective observational study of 477 individuals with new workers' compensation claims for CTS without acute trauma who were treated at 30 occupational health clinics from 2011 to 2013 and followed for 18 months. Timing of key clinical events, adherence to 45 quality measures, changes in scores on the Boston Carpal Tunnel Questionnaire and 12-item Short Form Health Survey Version 2 (SF-12v2), and costs associated with medical care and disability. Two hundred sixty-seven subjects (56%) received a diagnosis of CTS and had claims filed around the first visit to occupational health, 104 (22%) received a diagnosis before that visit and claim, and 98 (21%) received a diagnosis or had claims filed after that visit. One hundred seventy-eight (37%) subjects had time off work, which started around the time of surgery in 147 (83%) cases and lasted a median of 41 days (interquartile range = 42 days). The timing of diagnosis varied, but time off work was generally short and related to surgery. If associations of quality of care with key medical, economic, and quality-of-life outcomes are identified for work-associated CTS, systematic efforts to evaluate and improve quality of medical care for this condition are warranted.

  18. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis.

    PubMed

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.

  19. Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques.

    PubMed

    Nakamichi, Ken-ichi; Tachibana, Shintaro; Yamamoto, Seizo; Ida, Masayoshi

    2010-03-01

    To compare the outcomes of percutaneous carpal tunnel release (PCTR) and mini-open carpal tunnel release (mini-OCTR) using ultrasonographic guidance for both techniques. We included 74 hands of 65 women with idiopathic carpal tunnel syndrome (age, 52-71 y; mean, 58 y). Thirty-five hands of 29 women had the PCTR (release with a device consisting of an angled blade, guide, and holder, along a line midway between the median nerve and ulnar artery (safe line) under ultrasonography (incision, 4 mm), and 39 hands of 36 women had the mini-OCTR (release along the safe line, distally under direct vision (incision, 1-1.5 cm) and proximally under ultrasonography, using a device consisting of a basket punch and outer tube. Assessments at 3, 6, 13, 26, 52, and 104 weeks showed no significant differences in neurologic recovery between the groups (p > .05). The PCTR group had significantly less pain, greater grip and key-pinch strengths, and better satisfaction scores at 3 and 6 weeks (p < .05), and less scar sensitivity at 3, 6, and 13 weeks (p < .05). There were no complications. The PCTR provides the same neurologic recovery as does the mini-OCTR. The former leads to less postoperative morbidity and earlier functional return and achievement of satisfaction. Therapeutic III. Copyright 2010. Published by Elsevier Inc.

  20. Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD/CAM zirconia implant abutment.

    PubMed

    Protopapadaki, Maria; Monaco, Edward A; Kim, Hyeong-Il; Davis, Elaine L

    2013-11-01

    The predictable nature of the hot pressing ceramic technique has several applications, but no study was identified that evaluated its application to the fabrication of custom implant abutments. The purpose of this study was to compare the fracture resistance of an experimentally designed pressable metal ceramic custom implant abutment (PR) with that of a duplicate zirconia abutment (ZR). Two groups of narrow platform (NP) (Nobel Replace) implant abutment specimens were fabricated (n=10). The experimental abutment (PR) had a metal substructure cast with ceramic alloy (Lodestar) and veneered with leucite pressable glass ceramic (InLine PoM). Each PR abutment was individually scanned and 10 duplicate CAD/CAM ZR abutments were fabricated for the control group. Ceramic crowns (n=20) with the average dimensions of a human lateral incisor were pressed with lithium disilicate glass ceramic (IPS e.max Press) and bonded on the abutments with a resin luting agent (Multilink Automix). The specimens were subjected to thermocycling, cyclic loading, and finally static loading to failure with a computer-controlled Universal Testing Machine. An independent t test (1 sided) determined whether the mean values of the fracture load differed significantly (α=.05) between the 2 groups. No specimen failed during cyclic loading. Upon static loading, the mean (SD) load to failure was significantly higher for the PR group (525.89 [143.547] N) than for the ZR group (413.70 [35.515] N) for internal connection narrow platform bone-level implants (P=.025). Failure was initiated at the screw and internal connection level for both groups. It is possible to fabricate PR abutments that are stronger than ZR abutments for Nobel Biocare internal connection NP bone-level implants. The screw and the internal connection are the weak links for both groups. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Efficacy of topical chamomile oil for mild and moderate carpal tunnel syndrome: A randomized double-blind placebo-controlled clinical trial.

    PubMed

    Hashempur, Mohammad Hashem; Ghasemi, Mohammad Sadegh; Daneshfard, Babak; Ghoreishi, Parissa Sadat; Lari, Zeinab Nasiri; Homayouni, Kaynoosh; Zargaran, Arman

    2017-02-01

    To evaluate the efficacy of topical chamomile oil in patients with mild and moderate carpal tunnel syndrome (CTS). Eighty six patients with electrodiagnostic criteria of mild and moderate CTS were enrolled in this randomized double-blind placebo-controlled clinical trial and received wrist splint plus topical chamomile oil or placebo for 4 weeks. They were evaluated at the baseline and end of the study regarding functional and symptomatic scores, dynamometry, and electrodiagnostic indexes. Dynamometry, functionality, and symptom severity scores of the patients were significantly improved in the chamomile oil group compared with the placebo group (P = 0.040, P = 0.0001, P = 0.017, respectively). Additionally, compound latency of the median nerve in the chamomile oil group significantly decreased (P = 0.035) compared to the placebo group. Other electerodiagnostic measurements did not change significantly. Complementary treatment with topical chamomile oil may have some benefits for patients with mild and moderate CTS, both subjectively and objectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Psychosocial Risk Factors and the Association With Carpal Tunnel Syndrome: A Systematic Review.

    PubMed

    Mansfield, Michael; Thacker, Michael; Sandford, Fiona

    2017-10-01

    Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of the upper limb. Research has shown that associative factors for CTS include occupational and biomechanical elements, gender, and age. To date, no systematic review has been undertaken to determine specifically whether there are any psychosocial risk factors in developing CTS. The objective is to determine whether psychosocial factors are associated with and/or predict the development of CTS. A systematic review was conducted including searches of PubMed (MEDLINE), EMBASE, and CINAHL from inception to May 30, 2017. Quantitative studies must have investigated a minimum of 1 or more psychosocial factors-cognitive, affective, behavioral, vocational, or interpersonal processes (eg, social support)-and include a point or risk estimate. One reviewer conducted the search and 2 reviewers independently assessed eligibility and completed methodological quality assessment using a modified Downs and Black checklist. Data were analyzed narratively. Six moderate- to high-quality studies were included in the final review. Five studies reported a positive association between psychosocial factors and CTS, where psychosocial factors were more in those who reported CTS. One study reported no positive or negative association with CTS development. Four studies reported a negative association between psychosocial factors and CTS, where psychosocial factors were less in those who reported CTS. There is limited evidence for a positive association between psychosocial factors and CTS. However, this was not a consistent finding across all included studies. Further research is indicated in standardizing CTS diagnostic criteria and investigating other working environments.

  3. Symptoms, signs and nerve conduction velocities in patients with suspected carpal tunnel syndrome.

    PubMed

    Ntani, Georgia; Palmer, Keith T; Linaker, Cathy; Harris, E Clare; Van der Star, Richard; Cooper, Cyrus; Coggon, David

    2013-08-15

    To inform the clinical management of patients with suspected carpal tunnel syndrome (CTS) and case definition for CTS in epidemiological research, we explored the relation of symptoms and signs to sensory nerve conduction (SNC) measurements. Patients aged 20-64 years who were referred to a neurophysiology service for investigation of suspected CTS, completed a symptom questionnaire (including hand diagrams) and physical examination (including Tinel's and Phalen's tests). Differences in SNC velocity between the little and index finger were compared according to the anatomical distribution of symptoms in the hand and findings on physical examination. Analysis was based on 1806 hands in 908 patients (response rate 73%). In hands with numbness or tingling but negative on both Tinel's and Phalen's tests, the mean difference in SNC velocities was no higher than in hands with no numbness or tingling. The largest differences in SNC velocities occurred in hands with extensive numbness or tingling in the median nerve sensory distribution and both Tinel's and Phalen's tests positive (mean 13.8, 95% confidence interval (CI) 12.6-15.0 m/s). Hand pain and thumb weakness were unrelated to SNC velocity. Our findings suggest that in the absence of other objective evidence of median nerve dysfunction, there is little value in referring patients of working age with suspected CTS for nerve conduction studies if they are negative on both Tinel's and Phalen's tests. Alternative case definitions for CTS in epidemiological research are proposed according to the extent of diagnostic information available and the relative importance of sensitivity and specificity.

  4. Behavior and analysis of an integral abutment bridge.

    DOT National Transportation Integrated Search

    2013-08-01

    As a result of abutment spalling on the integral abutment bridge over 400 South Street in Salt Lake City, Utah, the Utah Department of Transportation (UDOT) instigated research measures to better understand the behavior of integral abutment bridges. ...

  5. Carpal tunnel syndrome assessment with ultrasonography: value of inlet-to-outlet median nerve area ratio in patients versus healthy volunteers.

    PubMed

    Fu, Tengfei; Cao, Manlin; Liu, Fang; Zhu, Jiaan; Ye, Dongmei; Feng, Xianxuan; Xu, Yiming; Wang, Gang; Bai, Yuehong

    2015-01-01

    To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS). Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of scaphoid-pisiform) and outlet (the level of the hook of the hamate), and the IOR was calculated for each wrist. Ultrasonography and electrodiagnostic tests were performed under blinded conditions. Electrodiagnostic testing combined with clinical symptoms were considered to be the gold standard test. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic value between the inlet CSA and IOR. The study population included 16 men and 30 women (mean age, 45.3 years; range, 18-83 years). The control population included 18 men and 26 women (mean age, 50.4 years; range, 18-79 years). The mean inlet CSA was 8.7 mm2 in healthy controls and 14.6mm2 in CTS group (P<0.001). The mean IOR in healthy volunteers (1.0) was smaller than that in patients (1.6, P<0.001). Receiver operating characteristic analysis revealed a diagnostic advantage to using the IOR rather than the inlet CSA (P<0.01). An IOR cutoff value of ≥ 1.3 would yield 93% specificity and 91% sensitivity in the diagnosis of CTS. The IOR of median nerve area promises to be an effective means in the diagnosis of CTS. A large-scale, randomized controlled trial is required to determine how and when this parameter will be used.

  6. [Resection of a carpal bone row in a Pustertaler Sprinze cow with chronic purulent arthritis of the carpal joint and osteomyelitis].

    PubMed

    Kofler, J; Peterbauer, C

    2014-01-01

    This case report describes the clinical and radiographic findings and the surgical treatment of a serofibrinous arthritis of the antebrachiocarpal joint and of a chronic purulent arthritis of the intercarpal and carpometacarpal joints with osteomyelitis of the distal carpal bones and subchondral osteomyelitis of the proximal metacarpal bones in a cow of the breed "Pustertaler Sprinze". The therapy comprised an arthrotomy of both joint spaces and the resection of the distal row of the carpal bones. The right forelimb had been immobilised for 70 days by a full limb cast. After this period, radiographs revealed an ob- vious ankylosis of the carpal joint, and the cow showed only a slight lameness. Six years postoperatively this cow was still in the herd and had produced six calves.

  7. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

    PubMed Central

    Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    ABSTRACT Objectives The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. Material and Methods A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. Results The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. Conclusions A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level. PMID:28496962

  8. Evaluation of Radiographic Instability of the Trapeziometacarpal Joint in Women With Carpal Tunnel Syndrome.

    PubMed

    Kim, Jeong Hwan; Gong, Hyun Sik; Kim, Youn Ho; Rhee, Seung Hwan; Kim, Jihyoung; Baek, Goo Hyun

    2015-07-01

    To determine whether median nerve dysfunction measured by electrophysiologic studies in carpal tunnel syndrome (CTS) is associated with thumb trapeziometacarpal (TMC) joint instability. We evaluated 71 women with CTS and 31 asymptomatic control women. Patients with generalized laxity or TMC joint osteoarthritis were excluded. We classified the electrophysiologic severity of CTS based on nerve conduction time and amplitude and assessed radiographic instability of the TMC joint based on TMC joint stress radiographs. We compared subluxation ratio between patients with CTS and controls and performed correlation analysis of the relationship between the electrophysiologic grade and subluxation ratio. Thirty-one patients were categorized into the mild CTS subgroup and 41 into the severe CTS subgroup. There was no significant difference in subluxation ratio between the control group and CTS patients or between the control group and CTS subgroup patients. Furthermore, there was no significant correlation between electrophysiologic grade and subluxation ratio. This study demonstrated that patients with CTS did not have greater radiographic TMC joint instability compared with controls, and suggests that TMC joint stability is not affected by impaired median nerve function. Further studies could investigate how to better evaluate proprioceptive function of TMC joint and whether other nerves have effects on TMC joint motor/proprioceptive function, to elucidate the relationship between neuromuscular control of the TMC joint, its stability, and its progression to osteoarthritis. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Carpal tunnel syndrome: assessment of surgeon and patient preferences and priorities for decision-making.

    PubMed

    Hageman, Michiel G J S; Kinaci, Ahmet; Ju, Kevin; Guitton, Thierry G; Mudgal, Chaitanya S; Ring, David

    2014-09-01

    This study tested the null hypothesis that there are no differences between the preferences of hand surgeons and those patients with carpal tunnel syndrome (CTS) facing decisions about management of CTS (ie, the preferred content of a decision aid). One hundred three hand surgeons of the Science of Variation Group and 79 patients with CTS completed a survey about their priorities and preferences in decision making regarding the management of CTS. The questionnaire was structured according the Ottawa Decision Support Framework for the development of a decision aid. Important areas on which patient and hand surgeon interests differed included a preference for nonpainful, nonoperative treatment and confirmation of the diagnosis with electrodiagnostic testing. For patients, the main disadvantage of nonoperative treatment was that it was likely to be only palliative and temporary. Patients preferred, on average, to take the lead in decision making, whereas physicians preferred shared decision making. Patients and physicians agreed on the value of support from family and other physicians in the decision-making process. There were some differences between patient and surgeon priorities and preferences regarding decision making for CTS, particularly the risks and benefits of diagnostic and therapeutic procedures. Information that helps inform patients of their options based on current best evidence might help patients understand their own preferences and values, reduce decisional conflict, limit surgeon-to-surgeon variations, and improve health. Copyright © 2014 American Society for Surgery of the Hand. All rights reserved.

  10. Attributable risk of carpal tunnel syndrome according to industry and occupation in a general population.

    PubMed

    Roquelaure, Yves; Ha, Catherine; Nicolas, Guillaume; Pélier-Cady, Marie-Christine; Mariot, Camille; Descatha, Alexis; Leclerc, Annette; Raimbeau, Guy; Goldberg, Marcel; Imbernon, Ellen

    2008-09-15

    An epidemiologic surveillance network for carpal tunnel syndrome (CTS) was set up in the general population of a French region to assess the proportion of CTS cases attributable to work in high-risk industries and occupations. Cases of CTS occurring among patients ages 20-59 years living in the Maine and Loire region were included prospectively from 2002 to 2004. Medical and occupation history was gathered by mailed questionnaire for 815 women and 320 men. Age-adjusted relative risks of CTS and the attributable risk fractions of CTS among exposed persons (AFEs) were computed in relation to industry sectors and occupation categories. Twenty-one industry sectors and 8 occupational categories for women and 10 sectors and 6 occupational categories for men were characterized by a significant excess risk of CTS. High AFE values were observed in the manufacturing (42-93% for both sexes), construction (66% for men), and personal service industries (66% for women) and in the trade and commerce sectors (49% for women). High AFE values were observed in lower-grade white-collar occupations for women (43-67%) and blue-collar occupations for men (60-74%) and women (48-88%). The attributable proportions of CTS cases among workers employed in industry sectors and occupation categories identified at high risk of CTS varied between 36% and 93%.

  11. General Population Job Exposure Matrix Applied to a Pooled Study of Prevalent Carpal Tunnel Syndrome

    PubMed Central

    Dale, Ann Marie; Zeringue, Angelique; Harris-Adamson, Carisa; Rempel, David; Bao, Stephen; Thiese, Matthew S.; Merlino, Linda; Burt, Susan; Kapellusch, Jay; Garg, Arun; Gerr, Fred; Hegmann, Kurt T.; Eisen, Ellen A.; Evanoff, Bradley

    2015-01-01

    A job exposure matrix may be useful for the study of biomechanical workplace risk factors when individual-level exposure data are unavailable. We used job title–based exposure data from a public data source to construct a job exposure matrix and test exposure-response relationships with prevalent carpal tunnel syndrome (CTS). Exposures of repetitive motion and force from the Occupational Information Network were assigned to 3,452 active workers from several industries, enrolled between 2001 and 2008 from 6 studies. Repetitive motion and force exposures were combined into high/high, high/low, and low/low exposure groupings in each of 4 multivariable logistic regression models, adjusted for personal factors. Although force measures alone were not independent predictors of CTS in these data, strong associations between combined physical exposures of force and repetition and CTS were observed in all models. Consistent with previous literature, this report shows that workers with high force/high repetition jobs had the highest prevalence of CTS (odds ratio = 2.14–2.95) followed by intermediate values (odds ratio = 1.09–2.27) in mixed exposed jobs relative to the lowest exposed workers. This study supports the use of a general population job exposure matrix to estimate workplace physical exposures in epidemiologic studies of musculoskeletal disorders when measures of individual exposures are unavailable. PMID:25700886

  12. Attributable risk of carpal tunnel syndrome according to industry and occupation in a general population

    PubMed Central

    Roquelaure, Yves; Ha, Catherine; Nicolas, Guillaume; Pélier-Cady, Marie-Christine; Mariot, Camille; Descatha, Alexis; Leclerc, Annette; Raimbeau, Guy; Goldberg, Marcel; Imbernon, Ellen

    2008-01-01

    Objectives An epidemiological surveillance network for carpal tunnel syndrome (CTS) was set up in the general population of a French region to assess the attributable fraction of CTS according to work in high risk industries and occupations. Methods Cases of CTS occurring among patients aged 20 to 59 living in the Maine and Loire region were included prospectively from 2002 to 2004. Medical and occupation history was gathered by mailed questionnaire for 815 women and 20 men. Age-adjusted relative risks of CTS and the attributable fractions of CTS to work among exposed persons (AFE) were computed in relation to industry sectors and occupation categories. Results Twenty-one industry sectors and eight occupational categories for women, and ten sectors and six occupational categories for men were characterized by a significant excess risk of CTS. High values of AFE were observed in the manufacturing (from 42 to 93% for both genders), construction (66 for men) and personal service industries (66 for women), and trade and commerce (49% for women) sectors. High values of AFE were observed in female lower grade white-collar occupations (from 43 to 67%), and male (from 60 to 74%) and female (from 48 to 88%) blue-collar occupations. Conclusion The attributable fractions of CTS among workers employed in industry sectors and occupation categories identified at high risk of CTS varied between 36 and 93% PMID:18759264

  13. Clinical Characteristics of Abutment Teeth with Gingival Discoloration.

    PubMed

    Ristic, Ljubisa; Dakovic, Dragana; Postic, Srdjan; Lazic, Zoran; Bacevic, Miljana; Vucevic, Dragana

    2017-04-06

    The grey-bluish discoloration of gingiva (known as "amalgam tattoo") does not appear only in the presence of amalgam restorations. It may also be seen in cases of teeth restored with cast dowels and porcelain-fused-to-metal (PFM) restorations. The aim of this article was to determine the clinical characteristics of abutment teeth with gingival discoloration. This research was conducted on 25 patients referred for cast dowel and PFM restorations. These restorations were manufactured from Ni-Cr alloys. Ninety days after cementing the fixed prosthodontic restorations, the abutment teeth (n = 61) were divided into a group with gingival discoloration (GD) (n = 25) and without gingival discoloration (NGD) (n = 36). The control group (CG) comprised the contralateral teeth (n = 61). Plaque index, gingival index, clinical attachment level, and probing depth were assessed before fabrication and also 90 days after cementation of the PFM restorations. The gingival index, clinical attachment level, and probing depths of the abutment teeth that had GD were statistically higher before restoration, in comparison with the abutment teeth in the NGD and control groups. Ninety days after cementation, the abutment teeth with GD had significantly lower gingival indexes and probing depths, compared to the abutment teeth in the NGD group. Both abutment teeth groups (GD and NGD) had significantly higher values of clinical attachment levels when compared to the control group. There were no statistically significant differences in plaque index values between the study groups. The results of this study indicated that impairment of periodontal status of abutment teeth seemed to be related to the presence of gingival discolorations. Therefore, fabrication of fixed prosthodontic restorations requires careful planning and abutment teeth preparation to minimize the occurrence of gingival discolorations. With careful preparation of abutment teeth for cast dowels and crown restorations it may be

  14. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection.

    PubMed

    Kim, Ki-Seong; Lim, Young-Jun; Kim, Myung-Joo; Kwon, Ho-Beom; Yang, Jae-Ho; Lee, Jai-Bong; Yim, Soon-Ho

    2011-08-01

    Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection. Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment). All abutments of each group were assembled and tightened with corresponding implants by a digital torque gauge. The total lengths of implant-abutment samples were measured at each torque (5, 10, 30 N cm and repeated 30 N cm with 10-min interval) by an electronic digital micrometer. The settling values were calculated by changes between the total lengths of implant-abutment samples. All groups developed settling with repeated tightening. The Int-H2 group showed markedly higher settling for all instances of tightening torque and the Ext group was the lowest. Statistically significant differences were found in settling values between the groups and statistically significant increases were observed within each group at different tightening torques (P<0.05). After the second tightening of 30 N cm, repeated tightening showed almost constant settling values. Results from the present study suggested that to minimize the settling effect, abutment screws should be retightened at least twice at 30 N cm torque at a 10-min interval in all laboratory and clinical procedures. © 2010 John Wiley & Sons A/S.

  15. [RESEARCH PROGRESS OF BIOMECHANICS OF PROXIMAL ROW CARPAL INSTABILITY].

    PubMed

    Guo, Jinhai; Huang, Fuguo

    2015-01-01

    To review the research progress of the biomechanics of proximal row carpal instability (IPRC). The related literature concerning IPRC was extensively reviewed. The biomechanical mechanism of the surrounding soft tissue in maintaining the stability of the proximal row carpal (PRC) was analyzed, and the methods to repair or reconstruct the stability and function of the PRC were summarized from two aspects including basic biomechanics and clinical biomechanics. The muscles and ligaments of the PRC are critical to its stability. Most scholars have reached a consensus about biomechanical mechanism of the PRC, but there are still controversial conclusions on the biomechanics mechanism of the surrounding soft tissue to stability of distal radioulnar joint when the triangular fibrocartilage complex are damaged and the biomechanics mechanism of the scapholunate ligament. At present, there is no unified standard about the methods to repair or reconstruct the stability and function of the PRC. So, it is difficult for clinical practice. Some strides have been made in the basic biomechanical study on muscle and ligament and clinical biomechanical study on the methods to repair or reconstruct the stability and function of PRC, but it will be needed to further study the morphology of carpal articular surface and the adjacent articular surface, the pressure of distal carpals to proximal carpal and so on.

  16. The influence of abutment screw tightening on screw joint configuration.

    PubMed

    Lang, Lisa A; Wang, Rui-Feng; May, Kenneth B

    2002-01-01

    Limiting abutment-to-implant hexagonal discrepancies and rotational movement of the abutment around the implant to less than 5 degrees would result in a more stable screw joint. However, the exact relationship after abutment screw tightening is unknown, as is the effect of a counter-torque device in limiting abutment movement during screw tightening. This study examined the orientation of the abutment hexagon to the implant hexagon after tightening of the abutment screw for several abutment systems with and without the use of a counter-torque device. Thirty conical self-tapping implants (3.75 x 10.0 mm) and 10 wide-platform Brånemark System implants (5.0 x 10.0 mm), along with 10 abutment specimens from the CeraOne, Estheticone, Procera, and AuraAdapt systems, were selected for this investigation. The implants were placed in a holding device prior to tightening of the abutments. When the tightening torque recommended for each abutment system was reached with the use of a torque controller, each implant abutment specimen was removed from the holding device and embedded in a hard resin medium. The specimens were sectioned in a horizontal direction at the level of the hexagons and cleansed of debris prior to examination. The hexagon orientations were assessed as the degree and direction of rotation of the abutment hexagon around the implant hexagon. The range of the maximum degrees of rotation for all 4 abutment groups tightened with or without the counter-torque device was slightly more than 3.53 degrees. The absolute degrees of rotation for all 4 abutment groups were less than 1.50 degrees with or without the use of the counter-torque device. The hexagon-to-hexagon orientation measured as rotational fit on all abutment systems was below the 5 degrees suggested as optimal for screw joint stability. The absolute degrees of rotation for all 4 abutment groups were less than 1.50 degrees regardless of whether the counter-torque device was used.

  17. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  18. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  19. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  20. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  1. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  2. Carpal tunnel syndrome and keyboard use at work: a population-based study.

    PubMed

    Atroshi, Isam; Gummesson, Christina; Ornstein, Ewald; Johnsson, Ragnar; Ranstam, Jonas

    2007-11-01

    To investigate the relationship between carpal tunnel syndrome (CTS) and keyboard use at work in a general population. A health status questionnaire was mailed to 2,465 persons of working age (25-65 years) who were randomly selected from the general population of a representative region of Sweden. The questionnaire required the subjects to provide information about the presence and severity of pain, numbness and tingling in each body region, employment history, and work activities, including average time spent using a keyboard during a usual working day. Those reporting recurrent hand numbness or tingling in the median nerve distribution were asked to undergo a physical examination and nerve conduction testing. The prevalence of CTS, defined as symptoms plus abnormal results on nerve conduction tests, was compared between groups of subjects that differed in their intensity of keyboard use, adjusting for age, sex, body mass index, and smoking status. Eighty-two percent responded to the questionnaire, and 80% of all symptomatic persons attended the examinations. Persons who had reported intensive keyboard use on the questionnaire were significantly less likely to be diagnosed as having CTS than were those who had reported little keyboard use, with a prevalence that increased from 2.6% in the highest keyboard use group (> or = 4 hours/day), to 2.9% in the moderate use group (1 to <4 hours/day), 4.9% in the low use group (<1 hour/day), and 5.2% in the no keyboard use at work group (P for trend = 0.032). Using > or = 1 hour/day to designate high keyboard use and <1 hour/day to designate low keyboard use, the prevalence ratio of CTS in the groups with high to low keyboard use was 0.55 (95% confidence interval 0.32, 0.96). Intensive keyboard use appears to be associated with a lower risk of CTS.

  3. Seasonal distribution and demographical characteristics of carpal tunnel syndrome in 1039 patients.

    PubMed

    Gomes, Irênio; Becker, Jefferson; Ehlers, João Arthur; Kapczinski, Flávio; Nora, Daniel Bocchese

    2004-09-01

    To describe the demographic characteristics of gender, age, and presence of repetitive movements, intake of alcohol and non-steroid anti-inflammatories (NSAI), medical specialties that referred patients to nerve conduction studies and electromyography (NCS-EMG), school attainment, and seasonal distribution in patients with a neurophysiological diagnosis of carpal tunnel syndrome (CTS) in the State of Rio Grande do Sul, Brazil. A series of 1039 patients (1549 hands) with neurophysiologically defined CTS was studied. Patients were referred for NCS-EMG in 3 universities and 2 private services, from August 2001 to January 2003. All patients completed a questionnaire containing demographic information. The diagnosis of CTS was established following a pre-established protocol, with defined diagnostic criteria. Around one fourth of patients had already performed NCS-EMG; the greatest frequency of CTS was observed in women (5.6:1) and in patients above the age of 40. Most patients reported performing repetitive movements in their daily routine (69.7%); 12.9% reported use of NSAI and 14.9% regular intake of alcoholic beverages. A greater frequency of CTS was observed in the months of July and August, when compared to the other months of the year. Around 2/3 of the study population had completed at least secondary school. Most requests of nerve conduction studies did not provide a diagnostic hypothesis (59.9%) and neurophysiologic studies were requested mostly by traumatology/orthopedics (71.1%). We have concluded that, in our environment, CTS shows some demographical characteristics that are similar to what the literature describes. Also, we have found that most of our sample concluded at least secondary school, and was referred to neurophysiologic studies by orthopedists. To be pointed out is the seasonal distribution of CTS, which demonstrates a significant association with winter months.

  4. [Spanish validation of the Boston Carpal Tunnel Questionnaire].

    PubMed

    Oteo-Álvaro, Ángel; Marín, María T; Matas, José A; Vaquero, Javier

    2016-03-18

    To describe the process of cultural adaptation and validation of the Boston Carpal Tunnel Questionnaire (BCTQ) measuring symptom intensity, functional status and quality of life in carpal tunnel syndrome patients and to report the psychometric properties of this version. A 3 expert panel supervised the adaptation process. After translation, review and back-translation of the original instrument, a new Spanish version was obtained, which was administered to 2 patient samples: a pilot sample of 20 patients for assessing comprehension, and a 90 patient sample for assessing structural validity (factor analysis and reliability), construct validity and sensitivity to change. A re-test measurement was carried out in 21 patients. Follow-up was accomplished in 40 patients. The questionnaire was well accepted by all participants. Celling effect was observed for 3 items. Reliability was very good, internal consistency: αS=0.91 y αF=0.87; test-retest stability: rS=0.939 and rF=0.986. Both subscales fitted to a general dimension. Subscales correlated with dynamometer measurements (rS=0.77 and rF=0.75) and showed to be related to abnormal 2-point discrimination, muscle atrophy and electromyography deterioration level. Scores properly correlated with other validated instruments: Douleur Neuropatique 4 questions and Brief Pain Inventory. BCTQ demonstrated to be sensitive to clinical changes, with large effect sizes (dS=-3.3 and dF=-1.9). The Spanish version of the BCTQ shows good psychometric properties warranting its use in clinical settings. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  5. Torque loss of different abutment sizes before and after cyclic loading.

    PubMed

    Moris, Izabela Cristina; Faria, Adriana Cláudia; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina

    2015-01-01

    The aim of this study was to compare 3.8- and 4.8-mm abutments submitted to simulations of masticatory cycles to examine whether abutment diameter and cemented vs screw-retained crowns affect torque loss of the abutments and crowns. Forty implant/abutment sets were divided into the following groups (n = 10 in each group): (1) G4.8S included 4.8-mm abutment with screw-retained crown; (2) G4.8C included 4.8-mm abutment with cemented crown; (3) G3.8S included 3.8-mm abutment with screw-retained crown; and (4) G3.8C included 3.8-mm abutment with cemented crown. All abutments were tightened with torque values of 20 Ncm, and 10 Ncm for screw-retained crowns. Torque loss was measured before and after cycling loading (300,000 cycles). Torque loss of screw-retained crowns significantly increased after cycling in abutments of groups G3.8S (P ≤ .05) and G4.8S (P = .001). No difference was noted between the abutments before cycling (P = .735), but G3.8S abutments presented greater torque loss than the other groups after cycling (P = .008). Significant differences were noted in the abutment torque loss before and after cycling loading only for the G3.8C group (P ≤ .05). The abutment diameter affects torque loss of screw-retained crowns and leads to failure during the test; mechanical cycling increases torque loss of abutment screw and screw-retained crowns.

  6. [Prevalence and Co-prevalence of Complex Regional Pain Syndrome (CRPS) and Carpal Tunnel Syndrome (CTS) in Hand Rehabilitation].

    PubMed

    Neubrech, F; Gentzsch, T; Kotsougiani, D; Bickert, B; Kneser, U; Harhaus, L

    2016-06-01

    In the current literature, there are reports of associations between complex regional pain syndromes (CRPS) and carpal tunnel syndromes (CTS). The aim of this study was to determine the prevalence of both disease patterns in hand rehabilitation patients and to investigate whether there is a correlation between CTS and CRPS. Furthermore, differences in the healing process of patients with and without additional CTS, and the effectiveness of the rehabilitative therapy for both diseases, were investigated. The computerised medical records of 791 patients in the years 2009-2015 who had been in hand rehabilitation were retrospectively analysed. At the beginning and end of rehabilitation, measurements were made of pain by visual analogue scales (VAS, 0-10), grip strength and finger mobility (mean distance from finger pulp to palmar D2-D5). The clinical course was statistically analysed. CRPS diagnosis was confirmed clinically by a pain therapist, CTS diagnosis was confirmed by neurological and neurophysiological examination. Surgical therapy was performed despite CRPS diagnosis. The prevalence of CRPS was 161/1000 and of CTS 62/1000; the co-prevalence of the 2 diagnoses was 24/1000 (p<0.0001). In the CRPS group, after a mean of 8 (1-21) weeks of rehabilitative therapy, mean pain was reduced from 5 (1-10) to 3 (0-9), grip strength improved from 10 (0-39)kg to 18.5 (2.5-45.5)kg and finger mobility increased from 2.9 (0-7.6)cm to 1.8 (0-7.8)cm. In the CRPS+CTS group, after a mean of 6.8 (3-23) weeks of rehabilitative therapy, mean pain was reduced from 5 (0-8) to 2.6 (0-5), grip strength improved from 9.7 (2.4-25.5)kg to 17.4 (0.9-47.4)kg and finger mobility increased from 2.7 (0-5.3)cm to 1.7 (0-5.3)cm. Improvement over the period of rehabilitation was significant in both groups, though the period of therapy was significantly shorter in the CRPS+CTS group. CRPS and CTS are often associated. Rehabilitative therapy was effective for CRPS- and CRPS+CTS patients. © Georg

  7. Associations Between Body Anthropometric Measures and Severity of Carpal Tunnel Syndrome.

    PubMed

    Mondelli, Mauro; Curti, Stefania; Mattioli, Stefano; Aretini, Alessandro; Ginanneschi, Federica; Greco, Giuseppe; Farioli, Andrea

    2016-09-01

    To assess the associations between carpal tunnel syndrome (CTS) severity and selected anthropometric and obesity indexes. We performed a case-control study. Clinical and electrophysiological severity of CTS was classified as mild, moderate, or severe based on validated scales. Body and hand anthropometric characteristics were measured at the time of the electrodiagnostic study. We estimated the relative risk ratios (RRRs) of CTS severity by fitting multinomial logistic regression models adjusted by age and sex. In addition, we fitted multivariable models, including age, sex, wrist ratio, hand ratio, body mass index (BMI), and waist/stature ratio. Electromyography laboratories. Consecutive patients (N=1087), those with CTS (n=340) and those without CTS (n=747), were enrolled. Not applicable. Associations between CTS severity and selected anthropometric and obesity indexes. We observed associations between many anthropometric indexes and CTS severity. Among obesity indexes, the waist/stature ratio, and among hand anthropometric indexes, the wrist/palm ratio, showed the highest RRRs for the clinical and electrophysiological severity scales. The RRRs of severe CTS (adjusted for age and sex) for the wrist/palm ratio were 3.5 for the clinical scale and 2.4 for the electrophysiological scale. The RRRs of severe CTS for the waist/stature ratio were 2.3 for the clinical scale and 2.0 for the electrophysiological scale. In the multivariable models, both BMI and the waist/stature ratio were associated with the outcomes. Different configurations of the body and, in particular, the hand and wrist system may influence the occurrence and severity of CTS. Multiple obesity indexes, possibly including the waist/stature ratio, should be considered when investigating the association between body composition and CTS. Future studies should determine whether in obese subjects with CTS the weight and waist circumference loss produces an improvement in CTS symptoms and recovery of distal

  8. Efficacy of low-level laser therapy associated to orthoses for patients with carpal tunnel syndrome: A randomized single-blinded controlled trial.

    PubMed

    Barbosa, Rafael Inácio; Fonseca, Marisa de Cássia Registro; Rodrigues, Eula Katucha da Silva; Tamanini, Guilherme; Marcolino, Alexandre Marcio; Mazzer, Nilton; Guirro, Rinaldo Roberto de Jesus; MacDermid, Joy

    2016-08-10

    Compare the efficacy of orthoses and patient education with and without the addition to Low-Level Laser Therapy (LLLT - 660 nm, 30 mW, a continuous regime and bean area of 0.06 cm2). The laser irradiation was delivered with the fluency of 10J/cm2 in patients with mild and moderate Carpal Tunnel Syndrome (CTS). 48 patients were randomized and 30 finished the protocol (a sample loss of 37.5%), 90% female and 10% males. Randomization was applied to allocate the patients in each one of the groups, with association or not to LLLT (group orthoses or LLLT and orthoses). All of them were submitted to ergonomic home orientations. The short-term symptoms and function outcome were assessed through: Boston Carpal Tunnel Questionnaire (BCTQ) - Severity of Symptoms (SS) Functional Score (FS). Pain (VAS), Semmes-Weinstein monofilaments, 2PD and pinch strength was used for characterization of the sample. Most of the participants were women, over 4th decade enrolled on heavy hand duties occupations, right-handed, 66.7% affected on dominant hand, without alterations in sensory median nerve thresholds or pinch strength. Both groups showed a reduction of total BCTQ score and its subdomains after six weeks, with significant difference (p< 0.05), comparing to baseline. No significant difference was found between groups. A Minimal clinical change was observed after the intervention in 92.3% of participants for BCTQ subdomain severity of symptoms at individual comparison for LLLT and orthoses group and 76.5% for the orthoses group, demonstrating clinical relevance. Effect size Cohen's index was moderate for the severity of symptoms. LLLT in association to orthoses and ergonomic orientation seems to be effective in short-term symptoms relieve for patients with mild and moderate CTS.

  9. Early return to work following open carpal tunnel decompression in lamb freezing workers.

    PubMed

    Wyatt, M C; Veale, G A

    2008-08-01

    Carpal tunnel syndrome is common at the largest lamb processing plant in the world, especially in new lamb boners. The purpose of this study was to establish the incidence and whether expeditious return to work following open carpal tunnel decompression was possible. Two hundred patients with a neurophysiologically confirmed diagnosis underwent surgery between 2002 and 2006. One hundred and eighty-seven patients were assessed retrospectively and 13 prospectively. The incidence in new lamb boners was 10% in their first season. On average, workers commenced rehabilitation at 11 days post-operatively and full duties at 29 days post-operatively with minimal further time off taken. Ninety percent returned to their previous role. By 8 weeks in the prospective group visual analogue pain scores had improved from 8.75 to 2.0 (P<0.01) and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores had improved from 140 points to 68 (P<0.01). Grip/pinch testing, static two-point discrimination scores and complication rates were comparable with previous studies. This study provides good evidence that coordinated, early rehabilitation and return to work is effective in a high-demand population.

  10. Screening for Acromegaly in Patients with Carpal Tunnel Syndrome: A Prospective Study (ACROCARP).

    PubMed

    Zoicas, F; Kleindienst, A; Mayr, B; Buchfelder, M; Megele, R; Schöfl, C

    2016-07-01

    Early diagnosis of acromegaly prevents irreversible comorbidities and facilitates surgical cure. Carpal tunnel syndrome (CTS) is common in acromegaly and patients have often undergone surgery for CTS prior to the diagnosis of acromegaly. We hypothesized that screening CTS-patients for acromegaly could facilitate active case-finding. We prospectively enrolled 196 patients [135 women, 56.9 (range 23-103) years] who presented with CTS for surgery. Patients were asked about 6 symptoms suggestive of acromegaly using a questionnaire calculating a symptom score (0-6 points), and insulin-like-growth factor 1 (IGF-1) was measured. If IGF-1 was increased, IGF-1 measurement was repeated, and random growth hormone (GH) and/or an oral glucose tolerance test (OGTT) with assessment of GH-suppression were performed. The mean symptom score was 1.7±1.3 points. Three patients reported the maximal symptom score of 6 points, but none of them had an increased IGF-1. There was no correlation between the symptom score and IGF-1-SDS (standard deviation score) (r=0.026; p=0.71). Four patients had an IGF-1>2 SDS. In 2 patients acromegaly was ruled out using random GH and OGTT. One patient had normal IGF-1 and random GH at follow-up. One patient refused further diagnostics. In this prospective cohort of patients with CTS, the observed frequency of acromegaly was at most 0.51% (95% CI 0.03 to 2.83%). In this prospective study, none of the 196 patients with CTS had proven acromegaly. Thus, we see no evidence to justify general screening of patients with CTS for acromegaly. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Prevalent involvement of thenar motor fibres in vineyard workers with carpal tunnel syndrome.

    PubMed

    Mondelli, M; Baldasseroni, A; Aretini, A; Ginanneschi, F; Padua, L

    2010-08-01

    Carpal tunnel syndrome (CTS) has a high prevalence in agricultural workers, especially those engaged in vineyards. We postulated that vineyard CTS was electrophysiologically different from CTS of other subjects. We performed a retrospective cross-sectional electrophysiological study of two cohorts of consecutive patients with CTS, the first consisting of vineyard workers and the second, of other unselected types of workers, housewives and pensioners. Thirty-three vineyard workers (mean age 46.8years, 42% women) and 205 patients with other occupations (mean age 53.7years; 66% women) were enrolled. All patients underwent sensory and motor neurography of the median and ulnar nerves. Differences in demographic and electrophysiological findings between groups were calculated and multiple linear regression analysis was performed to eliminate the influence of potential confounding factors (age, sex, BMI, clinical severity of CTS) on the results of univariate difference analysis. Univariate analysis showed that DML was longer and compound muscle action potential amplitude of the median nerve, recorded from the abductor pollicis brevis muscle, was smaller in vineyard workers than in the other CTS patients. These differences remained significant after adjusting the results for confounding factors. The vineyard workers showed a different pattern of CTS than the other patients: thenar motor fibres were more affected, presumably due to chronic compression on the thenar branch. This suggests an association between "common" CTS and thenar mononeuropathy. Occupational physiologists should clarify the mechanisms of neuromuscular engagement in particular jobs and ergonomists design suitable working tools, because many "individual" risk factors are difficult to change, but workplace-related risk factors can be modified. Copyright 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Symptoms, signs and nerve conduction velocities in patients with suspected carpal tunnel syndrome

    PubMed Central

    2013-01-01

    Background To inform the clinical management of patients with suspected carpal tunnel syndrome (CTS) and case definition for CTS in epidemiological research, we explored the relation of symptoms and signs to sensory nerve conduction (SNC) measurements. Methods Patients aged 20–64 years who were referred to a neurophysiology service for investigation of suspected CTS, completed a symptom questionnaire (including hand diagrams) and physical examination (including Tinel’s and Phalen’s tests). Differences in SNC velocity between the little and index finger were compared according to the anatomical distribution of symptoms in the hand and findings on physical examination. Results Analysis was based on 1806 hands in 908 patients (response rate 73%). In hands with numbness or tingling but negative on both Tinel’s and Phalen’s tests, the mean difference in SNC velocities was no higher than in hands with no numbness or tingling. The largest differences in SNC velocities occurred in hands with extensive numbness or tingling in the median nerve sensory distribution and both Tinel’s and Phalen’s tests positive (mean 13.8, 95% confidence interval (CI) 12.6-15.0 m/s). Hand pain and thumb weakness were unrelated to SNC velocity. Conclusions Our findings suggest that in the absence of other objective evidence of median nerve dysfunction, there is little value in referring patients of working age with suspected CTS for nerve conduction studies if they are negative on both Tinel’s and Phalen’s tests. Alternative case definitions for CTS in epidemiological research are proposed according to the extent of diagnostic information available and the relative importance of sensitivity and specificity. PMID:23947775

  13. The role of proprioception and neuromuscular stability in carpal instabilities.

    PubMed

    Hagert, E; Lluch, A; Rein, S

    2016-01-01

    Carpal stability has traditionally been defined as dependent on the articular congruity of joint surfaces, the static stability maintained by intact ligaments, and the dynamic stability caused by muscle contractions resulting in a compression of joint surfaces. In the past decade, a fourth factor in carpal stability has been proposed, involving the neuromuscular and proprioceptive control of joints. The proprioception of the wrist originates from afferent signals elicited by sensory end organs (mechanoreceptors) in ligaments and joint capsules that elicit spinal reflexes for immediate joint stability, as well as higher order neuromuscular influx to the cerebellum and sensorimotor cortices for planning and executing joint control. The aim of this review is to provide an understanding of the role of proprioception and neuromuscular control in carpal instabilities by delineating the sensory innervation and the neuromuscular control of the carpus, as well as descriptions of clinical applications of proprioception in carpal instabilities. © The Author(s) 2015.

  14. Sinking and fit of abutment of locking taper implant system

    PubMed Central

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  15. In vitro analysis of post-fatigue reverse-torque values at the dental abutment/implant interface for a unitarian abutment design.

    PubMed

    Cashman, Paul M; Schneider, Robert L; Schneider, Galen B; Stanford, Clark M; Clancy, James M; Qian, Fang

    2011-10-01

    This study analyzed baseline and post-fatigue reverse-torque values (RTVs) for a specific brand control abutment relative to a third party compatible abutment. The purpose of this study was to compare the abutments' fatigue resistance to simulated function, using RTVs as an indication of residual preload at the implant/abutment interface. Forty Straumann tissue-level implants were mounted in resin and divided into four groups (n = 10). Forty abutments were seated, 20 control and 20 third-party abutments, according to manufacturer guidelines. Ten abutments from each manufacturer were evaluated for RTV without fatigue loading, using a calibrated digital torque gauge to provide a baseline RTVs. Fatigue loading was carried out on the remaining ten specimens from each manufacturer according to ISO 14801 guidelines. A moving-magnet linear motor was used to load one specimen per sequence, alternating from 10 to 200 N at 15 Hz for 5×10(6) cycles. RTV was recorded post-fatigue loading. The results were subjected to two-sample t-testing and two-way ANOVA. Scanning electron microphotography was carried out on three specimens from both manufacturers at baseline and post-fatigue cycling to visualize thread geometry and the abutment/implant interface. The data indicated that mean post-fatigue RTV observed for the control group was significantly higher than the third-party group (RTV 42.65 ± 6.70 N vs. 36.25 ± 2.63 N, p= 0.0161). Visual differences at the macro/microscopic level were also apparent for thread geometry, with third-party abutments demonstrating considerably greater variation in geometrical architecture than control specimens. Within the limitations of this in vitro model, the effect of component manufacturer resulted in a significantly higher RTV in the control group (two-way ANOVA, p= 0.0032) indicating greater residual preload; however, there was no significant decrease in post-fatigue RTV for either manufacturer compared to baseline. © 2011 by The American

  16. Value of F-wave inversion in diagnosis of carpal tunnel syndrome and it's relation with anthropometric measurements.

    PubMed

    Komurcu, Hatice Ferhan; Kilic, Selim; Anlar, Omer

    2015-01-01

    The clinical importance of F-wave inversion in the diagnosis of Carpal Tunnel Syndrome (CTS) is not yet well known. This study aims to investigate the value of F-wave inversion in diagnosing CTS, and to evaluate the relationship of F-wave inversion with age, gender, diabetes mellitus, body mass index (BMI), wrist or waist circumferences. Patients (n=744) who were considered to have CTS with clinical findings were included in the study. In order to confirm the diagnosis of CTS, standard electrophysiological parameters were studied with electroneuromyography. In addition, median nerve F-wave measurements were done and we determined if F-wave inversion was present or not. Sensitivity and specificity of F-wave inversion were investigated for its value in showing CTS diagnosed by electrophysiological examination. CTS diagnosis was confirmed by routine electrophysiological parameters in 307 (41.3%) patients. The number of the patients with the presence of F-wave inversion was 243 (32.7%). Sensitivity of F-wave inversion was found as 56% and specificity as 83.8%. BMI and wrist circumference values were significantly higher in patients with F-wave inversion present than those with F-wave inversion absent (p=0.0033, p=0.025 respectively). F-wave inversion can be considered as a valuable electrophysiological measurement for screening of CTS.

  17. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  18. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  19. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  20. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  1. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  2. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  3. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  4. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  5. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  6. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  7. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  8. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  9. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  10. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  11. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  12. Custom-made laser-welded titanium implant prosthetic abutment.

    PubMed

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  13. A comparison of data sources for the surveillance of work-related carpal tunnel syndrome in Massachusetts.

    PubMed

    Davis, Letitia; Wellman, Helen; Hart, James; Cleary, Robert; Gardstein, Betsey M; Sciuchetti, Paul

    2004-09-01

    This study examined whether a state surveillance system for work-related carpal tunnel syndrome (WR-CTS) based on workers' compensation claims (Sentinel Event Notification System for Occupational Risks, SENSOR) and the Annual Survey of Occupational Injuries and Illnesses (SOII) identified the same industries, occupations, sources of injury, and populations for intervention. Trends in counts, rates, and female/male ratios of WR-CTS during 1994-1997, and age distributions were compared across three data sources: SENSOR, Massachusetts SOII, and National SOII. SENSOR and National SOII data on WR-CTS were compared by industry, occupation, and injury source. Due to small sample size and subsequent gaps in available information, state SOII data on WR-CTS were of little use in identifying specific industries and occupations for intervention. SENSOR and National SOII data on the frequency of WR-CTS cases identified many similar occupations and industries, and both surveillance systems pointed to computer use as a risk factor for WR-CTS. Some high rate industries identified by SENSOR were not identified using National SOII rates even when national findings were restricted to take into account the distribution of the Massachusetts workforce. Use of national SOII data on rates of WR-CTS for identifying state industry priorities for WR-CTS prevention should be undertaken with caution. Options for improving state SOII data and use of other state data systems should be pursued.

  14. Relationship between Semmes-Weinstein Monofilaments perception Test and sensory nerve conduction studies in Carpal Tunnel Syndrome.

    PubMed

    Raji, Parvin; Ansari, Noureddin Nakhostin; Naghdi, Soofia; Forogh, Bijan; Hasson, Scott

    2014-01-01

    The Semmes-Weinstein Monofilament Test (SWMT) is a clinical widely used test to quantify the sensibility in patients with Carpal Tunnel Syndrome (CTS). No study has investigated the relationship between the SWMT and sensory nerve conduction studies (SNCS) in patients with CTS. To assess the relationship between the SWMT and SNCS findings in patients with CTS. This cross-sectional clinical measurement study included 35 patients with CTS (55 hands) with a mean age of 45 ± 12 years. The outcome measures were the SWMT and SNCS measures of distal latency (DLs), amplitude (AMPs), and nerve conduction velocity (NCV). The median innervated fingers were tested using SWMT and electrodiagnostic tests. The primary outcome was the correlations between the SWMTs and NCS measures. All of the patients/hands had abnormal NCS findings. When looking at the three digits of interest (thumb, index and middle), the thumb SWMTs had the highest number of abnormal findings (58.2%), with the middle digit having the lowest (45.5%). All NCS findings were statistically different between abnormal and normal thumb SWMTs and abnormal and normal total summed SWMTs. There were significant moderate correlations between thumb SWMT scores and all NCS outcomes. Although only approximately 50% of the CTS diagnosed through NCS are corroborated through SWMT; the significant associations between SWMT and NCS measures suggest that SWMT is a valid test for assessing sensations in patients with CTS.

  15. Scour around vertical wall abutment in cohesionless sediment bed

    NASA Astrophysics Data System (ADS)

    Pandey, M.; Sharma, P. K.; Ahmad, Z.

    2017-12-01

    At the time of floods, failure of bridges is the biggest disaster and mainly sub-structure (bridge abutments and piers) are responsible for this failure of bridges. It is very risky if these sub structures are not constructed after proper designing and analysis. Scour is a natural phenomenon in rivers or streams caused by the erosive action of the flowing water on the bed and banks. The abutment undermines due to river-bed erosion and scouring, which generally recognized as the main cause of abutment failure. Most of the previous studies conducted on scour around abutment have concerned with the prediction of the maximum scour depth (Lim, 1994; Melvill, 1992, 1997 and Dey and Barbhuiya, 2005). Dey and Barbhuiya (2005) proposed a relationship for computing maximum scour depth near an abutment, based on laboratory experiments, for computing maximum scour depth around vertical wall abutment, which was confined to their experimental data only. However, this relationship needs to be also verified by the other researchers data in order to support the reliability to the relationship and its wider applicability. In this study, controlled experimentations have been carried out on the scour near a vertical wall abutment. The collected data in this study along with data of the previous investigators have been carried out on the scour near vertical wall abutment. The collected data in this study along with data of the previous have been used to check the validity of the existing equation (Lim, 1994; Melvill, 1992, 1997 and Dey and Barbhuiya, 2005) of maximum scour depth around the vertical wall abutment. A new relationship is proposed to estimate the maximum scour depth around vertical wall abutment, it gives better results all relationships.

  16. Upper bound of abutment scour in laboratory and field data

    USGS Publications Warehouse

    Benedict, Stephen

    2016-01-01

    The U.S. Geological Survey, in cooperation with the South Carolina Department of Transportation, conducted a field investigation of abutment scour in South Carolina and used those data to develop envelope curves that define the upper bound of abutment scour. To expand on this previous work, an additional cooperative investigation was initiated to combine the South Carolina data with abutment scour data from other sources and evaluate upper bound patterns with this larger data set. To facilitate this analysis, 446 laboratory and 331 field measurements of abutment scour were compiled into a digital database. This extensive database was used to evaluate the South Carolina abutment scour envelope curves and to develop additional envelope curves that reflected the upper bound of abutment scour depth for the laboratory and field data. The envelope curves provide simple but useful supplementary tools for assessing the potential maximum abutment scour depth in the field setting.

  17. Design of piles for integral abutment bridges.

    DOT National Transportation Integrated Search

    1984-08-01

    More and more, integral abutment bridges are being used in place : of the more traditional bridge designs with expansion releases. In : this study, states which use integral abutment bridges were surveyed : to determine their current practice in the ...

  18. FEA and microstructure characterization of a one-piece Y-TZP abutment.

    PubMed

    da Silva, Lucas Hian; Ribeiro, Sebastião; Borges, Alexandre Luís Souto; Cesar, Paulo Francisco; Tango, Rubens Nisie

    2014-11-01

    The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw. Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured. FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region. In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Tarsal tunnel syndrome in a patient on long-term peritoneal dialysis: case report.

    PubMed

    Ozdemir, Ozgür; Calişaneller, Tarkan; Sönmez, Erkin; Altinörs, Nur

    2007-10-01

    Tarsal tunnel syndrome (TTS) is defined as the entrapment of the posterior tibial nerve in the tarsal tunnel of the ankle. The etiologies of tarsal tunnel syndrome are mainly the presence of a ganglion, osseous prominence with tarsal bone coalition, trauma, varicose veins, neurinoma, hypertrophy of the flexor retinaculum, or systemic disease (rheumatoid arthritis, ankylosing spondylitis). However, no specific cause can be identified in some cases. Patients with chronic renal failure tend to develop peripheral nerve entrapment and carpal tunnel syndrome is the best-known peripheral entrapment neuropathy among them. Contrary to carpal tunnel syndrome, tarsal tunnel syndrome is observed less frequently in chronic renal failure patients. The common presenting symptoms of TTS are paresthesias and/or pain in the plantar side of the foot. Motor symptoms are rarely detected. Diagnosis is made primarily by electroneuromyographic studies and physical examination. Surgery is the treatment of choice and the outcome is generally favourable. In this report, we present a patient with tarsal tunnel syndrome complicating peritoneal dialysis.

  20. Implant-abutment connections on single crowns: a systematic review.

    PubMed

    Ceruso, F M; Barnaba, P; Mazzoleni, S; Ottria, L; Gargari, M; Zuccon, A; Bruno, G; DI Fiore, A

    2017-01-01

    Different implant-abutment connections have been developed in the effort of reducing mechanical and biological failure. The most frequent complications are screw loosening, abutment or implant fracture and marginal bone loss due to overload and bacterial micro-leakage. Ideal connection should work as a one-piece implant avoiding the formation of a micro-gap at the implant-abutment interface. Different in vitro and in vivo researches have been published to compare the implant-abutment connections actually available: external hexagon, internal hexagon and conical finding different amount of micro-gap, micro-leakage and marginal bone loss. The aim of this article is to describe, according to the most recent literature, different kind of fixture-abutment connections and their clinical and mechanical advantages or disadvantages.

  1. [Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].

    PubMed

    Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L

    2016-08-20

    Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P <0.05) , while there were no significant differences in the thickness of transverse carpal ligament at the level of the hamulus of hamate bone and the cross-sectional area of the median nerve at the level of pisiform bone ( t=- 9.397 and -4.385, both P >0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.

  2. Fracture loads and failure modes of customized and non-customized zirconia abutments.

    PubMed

    Moris, Izabela Cristina Maurício; Chen, Yung-Chung; Faria, Adriana Cláudia Lapria; Ribeiro, Ricardo Faria; Fok, Alex Sui-Lun; Rodrigues, Renata Cristina Silveira

    2018-05-05

    This study aimed to evaluate the fracture load and pattern of customized and non-customized zirconia abutments with Morse-taper connection. 18 implants were divided into 3 groups according to the abutments used: Zr - with non-customized zirconia abutments; Zrc - with customized zirconia abutments; and Ti - with titanium abutments. To test their load capacity, a universal test machine with a 500-kgf load cell and a 0.5-mm/min speed were used. After, one implant-abutment assembly from each group was analyzed by Scanning Electron Microscopy (SEM). For fractographic analysis, the specimens were transversely sectioned above the threads of the abutment screw in order to examine their fracture surfaces using SEM. A significant difference was noted between the groups (Zr=573.7±11.66N, Zrc=768.0±8.72N and Ti=659.1±7.70N). Also, the zirconia abutments fractured while the titanium abutments deformed plastically. Zrc presented fracture loads significantly higher than Zr (p=0.009). All the zirconia abutments fractured below the implant platform, starting from the area of contact between the abutment and implant and propagating to the internal surface of the abutment. All the zirconia abutments presented complete cleavage in the mechanical test. Fractography detected differences in the position and pattern of fracture between the two groups with zirconia abutments, probably because of the different diameters in the transmucosal region. Customization of zirconia abutments did not affect their fracture loads, which were comparable to that of titanium and much higher than the maximum physiological limit for the anterior region of the maxilla. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  3. Reliability and Failure Modes of a Hybrid Ceramic Abutment Prototype.

    PubMed

    Silva, Nelson Rfa; Teixeira, Hellen S; Silveira, Lucas M; Bonfante, Estevam A; Coelho, Paulo G; Thompson, Van P

    2018-01-01

    A ceramic and metal abutment prototype was fatigue tested to determine the probability of survival at various loads. Lithium disilicate CAD-milled abutments (n = 24) were cemented to titanium sleeve inserts and then screw attached to titanium fixtures. The assembly was then embedded at a 30° angle in polymethylmethacrylate. Each (n = 24) was restored with a resin-cemented machined lithium disilicate all-ceramic central incisor crown. Single load (lingual-incisal contact) to failure was determined for three specimens. Fatigue testing (n = 21) was conducted employing the step-stress method with lingual mouth motion loading. Failures were recorded, and reliability calculations were performed using proprietary software. Probability Weibull curves were calculated with 90% confidence bounds. Fracture modes were classified with a stereomicroscope, and representative samples imaged with scanning electron microscopy. Fatigue results indicated that the limiting factor in the current design is the fatigue strength of the abutment screw, where screw fracture often leads to failure of the abutment metal sleeve and/or cracking in the implant fixture. Reliability for completion of a mission at 200 N load for 50K cycles was 0.38 (0.52% to 0.25 90% CI) and for 100K cycles was only 0.12 (0.26 to 0.05)-only 12% predicted to survive. These results are similar to those from previous studies on metal to metal abutment/fixture systems where screw failure is a limitation. No ceramic crown or ceramic abutment initiated fractures occurred, supporting the research hypothesis. The limiting factor in performance was the screw failure in the metal-to-metal connection between the prototyped abutment and the fixture, indicating that this configuration should function clinically with no abutment ceramic complications. The combined ceramic with titanium sleeve abutment prototype performance was limited by the fatigue degradation of the abutment screw. In fatigue, no ceramic crown or ceramic

  4. Biomechanical risk factors for carpal tunnel syndrome: a pooled study of 2474 workers

    PubMed Central

    Harris-Adamson, Carisa; Eisen, Ellen A; Kapellusch, Jay; Garg, Arun; Hegmann, Kurt T; Thiese, Matthew S; Dale, Ann Marie; Evanoff, Bradley; Burt, Susan; Bao, Stephen; Silverstein, Barbara; Merlino, Linda; Gerr, Fred; Rempel, David

    2015-01-01

    Background Between 2001 and 2010, five research groups conducted coordinated prospective studies of carpal tunnel syndrome (CTS) incidence among US workers from various industries and collected detailed subject-level exposure information with follow-up of symptoms, electrophysiological measures and job changes. Objective This analysis examined the associations between workplace biomechanical factors and incidence of dominant-hand CTS, adjusting for personal risk factors. Methods 2474 participants, without CTS or possible polyneuropathy at enrolment, were followed up to 6.5 years (5102 person-years). Individual workplace exposure measures of the dominant hand were collected for each task and included force, repetition, duty cycle and posture. Task exposures were combined across the workweek using time-weighted averaging to estimate job-level exposures. CTS case-criteria were based on symptoms and results of electrophysiological testing. HRs were estimated using Cox proportional hazard models. Results After adjustment for covariates, analyst (HR=2.17; 95% CI 1.38 to 3.43) and worker (HR=2.08; 95% CI 1.31 to 3.39) estimated peak hand force, forceful repetition rate (HR=1.84; 95% CI 1.19 to 2.86) and per cent time spent (eg, duty cycle) in forceful hand exertions (HR=2.05; 95% CI 1.34 to 3.15) were associated with increased risk of incident CTS. Associations were not observed between total hand repetition rate, per cent duration of all hand exertions, or wrist posture and incident CTS. Conclusions In this prospective multicentre study of production and service workers, measures of exposure to forceful hand exertion were associated with incident CTS after controlling for important covariates. These findings may influence the design of workplace safety programmes for preventing work-related CTS. PMID:25324489

  5. Somatosensory cortical plasticity in carpal tunnel syndrome--a cross-sectional fMRI evaluation.

    PubMed

    Napadow, Vitaly; Kettner, Norman; Ryan, Angela; Kwong, Kenneth K; Audette, Joseph; Hui, Kathleen K S

    2006-06-01

    Carpal tunnel syndrome (CTS) is a common entrapment neuropathy of the median nerve characterized by paresthesias and pain in the first, second, and third digits. We hypothesize that aberrant afferent input in CTS will lead to cortical plasticity. Functional MRI (fMRI) and neurophysiological testing were performed on CTS patients and healthy adults. Median nerve innervated digit 2 (D2), and digit 3 (D3) and ulnar nerve innervated digit 5 (D5) were stimulated during fMRI. Surface-based and ROI-based analyses consistently demonstrated more extensive and stronger contralateral sensorimotor cortical representations of D2 and D3 for CTS patients as compared to healthy adults (P < 0.05). Differences were less profound for D5. Moreover, D3 fMRI activation in both the contralateral SI and motor cortex correlated positively with the D3 sensory conduction latency. Analysis of somatotopy suggested that contralateral SI representations for D2 and D3 were less separated for CTS patients (3.8 +/- 1.0 mm) than for healthy adults (7.5 +/- 1.2 mm). Furthermore, the D3/D2 separation distance correlated negatively with D2 sensory conduction latency-the greater the latency, the closer the D2/D3 cortical representations (r = -0.79, P < 0.05). Coupled with a greater extent of SI representation for these CTS affected digits, the closer cortical representations can be interpreted as a blurred somatotopic arrangement for CTS affected digits. These findings provide further evidence that CTS is not manifest in the periphery alone. Our results are consistent with Hebbian plasticity mechanisms, as our cohort of CTS patients had predominant paresthesias, which produce more temporally coherent afferent signaling from affected digits.

  6. Carpal tunnel syndrome and computer exposure at work in two large complementary cohorts

    PubMed Central

    Mediouni, Z; Bodin, J; Dale, A M; Herquelot, E; Carton, M; Leclerc, A; Fouquet, N; Dumontier, C; Roquelaure, Y; Evanoff, B A; Descatha, A

    2015-01-01

    Objectives The boom in computer use and concurrent high rates in musculoskeletal complaints and carpal tunnel syndrome (CTS) among users have led to a controversy about a possible link. Most studies have used cross-sectional designs and shown no association. The present study used longitudinal data from two large complementary cohorts to evaluate a possible relationship between CTS and the performance of computer work. Settings and participants The Cosali cohort is a representative sample of a French working population that evaluated CTS using standardised clinical examinations and assessed self-reported computer use. The PrediCTS cohort study enrolled newly hired clerical, service and construction workers in several industries in the USA, evaluated CTS using symptoms and nerve conduction studies (NCS), and estimated exposures to computer work using a job exposure matrix. Primary and secondary outcome measures During a follow-up of 3–5 years, the association between new cases of CTS and computer work was calculated using logistic regression models adjusting for sex, age, obesity and relevant associated disorders. Results In the Cosali study, 1551 workers (41.8%) completed follow-up physical examinations; 36 (2.3%) participants were diagnosed with CTS. In the PrediCTS study, 711 workers (64.2%) completed follow-up evaluations, whereas 31 (4.3%) had new cases of CTS. The adjusted OR for the group with the highest exposure to computer use was 0.39 (0.17; 0.89) in the Cosali cohort and 0.16 (0.05; 0.59) in the PrediCTS cohort. Conclusions Data from two large cohorts in two different countries showed no association between computer work and new cases of CTS among workers in diverse jobs with varying job exposures. CTS is far more common among workers in non-computer related jobs; prevention efforts and work-related compensation programmes should focus on workers performing forceful hand exertion. PMID:26353869

  7. Prevalence and Work-Relatedness of Carpal Tunnel Syndrome in the Working Population, United States, 2010 National Health Interview Survey

    PubMed Central

    Luckhaupt, Sara E.; Dahlhamer, James M.; Ward, Brian W.; Sweeney, Marie H.; Sestito, John P.; Calvert, Geoffrey M.

    2015-01-01

    Background Patterns of prevalence and work-relatedness of carpal tunnel syndrome (CTS) among workers offer clues about risk factors and targets for prevention. Methods Data from an occupational health supplement to the 2010 National Health Interview Survey were used to estimate the prevalence of self-reported clinician-diagnosed CTS overall and by demographic characteristics. The proportion of these cases self-reported to have been attributed to work by clinicians was also examined overall and by demographic characteristics. In addition, the distribution of industry and occupation (I&O) categories to which work-related cases of CTS were attributed was compared to the distribution of I&O categories of employment among current/recent workers. Results Data were available for 27,157 adults, including 17,524 current/recent workers. The overall lifetime prevalence of clinician-diagnosed CTS among current/recent workers was 6.7%. The 12-month prevalence was 3.1%, representing approximately 4.8 million workers with current CTS; 67.1% of these cases were attributed to work by clinicians, with overrepresentation of certain I&O categories. Conclusions CTS affected almost 5 million U.S. workers in 2010, with prevalence varying by demographic characteristics and I&O. PMID:22495886

  8. Evaluation of Associated Carpal Bone Fractures in Distal Radial Fractures

    PubMed Central

    Heo, Youn Moo; Kim, Sang Bum; Yi, Jin Woong; Park, Cheol Yong; Yoon, Jeong Yong; Kim, Doo Hyun

    2013-01-01

    Background The purpose of this study was to investigate the frequency and distribution of associated carpal bone fractures (CBFs) in distal radial fractures (DRFs). Methods Three hundred and thirteen patients who underwent surgical treatment for DRFs between March 2007 and January 2010 were reviewed retrospectively. In this study, 223 patients who had preoperative computed tomography (CT) were included. We investigated the frequency and distribution of associated CBFs on CT scans. The relationship between the frequency of associated CBFs and patient factors such as age, gender, body mass index, and the mechanism of injury was assessed. Results CBFs were complicated in 46 of 223 DRFs (20.9%). The distribution of CBFs was 23 cases in the triquetrum, 16 in the lunate, 12 in the scaphoid, five in the hamate, and four in the pisiform. Among the 46 cases, a fracture of one carpal bone occurred in 36 cases, two in seven cases, three in two cases, and four in one case. In 10 of the 46 cases, associated CBFs occurred in more than two carpal bones. No significant differences were observed for age, sex, body mass index, or the mechanism of injury between patients with DRFs and CBFs and those without CBFs. Conclusions Because CBFs that mainly occur in the proximal carpal row are complicated in DRFs at a relatively high frequency, assessment of carpal bones using CT scans is beneficial. PMID:23730472

  9. Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment-crown-connections after cyclic loading.

    PubMed

    Moris, Izabela Cristina Maurício; Faria, Adriana Cláudia Lapria; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira

    2017-04-01

    The aim of this study was to analyze failure modes and misfit of abutments with reduced diameter for both cement and screw retentions after cyclic loading. Forty morse-taper abutment/implant sets of titanium were divided into four groups (N = 10): G4.8S-4.8 abutment with screw-retained crown; G4.8C-4.8 abutment with cemented crown; G3.8S-3.8 abutment with screw-retained crown; and G3.8C-3.8 abutment with cemented crown. Copings were waxed on castable cylinders and cast by oxygen gas flame and injected by centrifugation. After, esthetic veneering ceramic was pressed on these copings for obtaining metalloceramic crowns of upper canine. Cemented crowns were cemented on abutments with provisional cement (Temp Bond NE), and screw-retained crowns were tightened to their abutments with torque recommended by manufacturer (10 N cm). The misfit was measured using a stereomicroscope in a 10× magnification before and after cyclic loading (300,000 cycles). Tests were visually monitored, and failures (decementation, screw loosening and fractures) were registered. Misfit was analyzed by mixed linear model while failure modes by chi-square test (α = 0.05). Cyclic loading affected misfit of 3.8C (P ≤ 0.0001), 3.8S (P = 0.0055) and 4.8C (P = 0.0318), but not of 4.8S (P = 0.1243). No differences were noted between 3.8S with 4.8S before (P = 0.1550) and after (P = 0.9861) cyclic loading, but 3.8C was different from 4.8C only after (P = 0.0015) loading. Comparing different types of retentions at the same diameter abutment, significant difference was noted before and after cyclic loading for 3.8 and 4.8 abutments. Analyzing failure modes, retrievable failures were present at 3.8S and 3.8C groups, while irretrievable were only present at 3.8S. The cyclic loading decreased misfit of cemented and screw-retained crowns on reduced diameter abutments, and misfit of cemented crowns is greater than screw-retained ones. Abutments of reduced diameter failed more than

  10. Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique

    PubMed Central

    Siadat, Hakimeh; Arshad, Mahnaz; Mahgoli, Hossein-Ali; Fallahi, Babak

    2016-01-01

    Objectives: Microbial leakage through the implant-abutment (I-A) interface results in bacterial colonization in two-piece implants. The aim of this study was to compare microleakage rates in three types of Replace abutments namely Snappy, GoldAdapt, and customized ceramic using radiotracing. Materials and Methods: Three groups, one for each abutment type, of five implants and one positive and one negative control were considered (a total of 17 regular body implants). A torque of 35 N/cm was applied to the abutments. The samples were immersed in thallium 201 radioisotope solution for 24 hours to let the radiotracers leak through the I-A interface. Then, gamma photons received from the radiotracers were counted using a gamma counter device. In the next phase, cyclic fatigue loading process was applied followed by the same steps of immersion in the radioactive solution and photon counting. Results: Rate of microleakage significantly increased (P≤0.05) in all three types of abutments (i.e. Snappy, GoldAdapt, and ceramic) after cyclic loading. No statistically significant differences were observed between abutment types after cyclic loading. Conclusions: Microleakage significantly increases after cyclic loading in all three Replace abutments (GoldAdapt, Snappy, ceramic). Lowest microleakage before and after cyclic loading was observed in GoldAdapt followed by Snappy and ceramic. PMID:28392814

  11. Global spectral graph wavelet signature for surface analysis of carpal bones

    NASA Astrophysics Data System (ADS)

    Masoumi, Majid; Rezaei, Mahsa; Ben Hamza, A.

    2018-02-01

    Quantitative shape comparison is a fundamental problem in computer vision, geometry processing and medical imaging. In this paper, we present a spectral graph wavelet approach for shape analysis of carpal bones of the human wrist. We employ spectral graph wavelets to represent the cortical surface of a carpal bone via the spectral geometric analysis of the Laplace-Beltrami operator in the discrete domain. We propose global spectral graph wavelet (GSGW) descriptor that is isometric invariant, efficient to compute, and combines the advantages of both low-pass and band-pass filters. We perform experiments on shapes of the carpal bones of ten women and ten men from a publicly-available database of wrist bones. Using one-way multivariate analysis of variance (MANOVA) and permutation testing, we show through extensive experiments that the proposed GSGW framework gives a much better performance compared to the global point signature embedding approach for comparing shapes of the carpal bones across populations.

  12. Global spectral graph wavelet signature for surface analysis of carpal bones.

    PubMed

    Masoumi, Majid; Rezaei, Mahsa; Ben Hamza, A

    2018-02-05

    Quantitative shape comparison is a fundamental problem in computer vision, geometry processing and medical imaging. In this paper, we present a spectral graph wavelet approach for shape analysis of carpal bones of the human wrist. We employ spectral graph wavelets to represent the cortical surface of a carpal bone via the spectral geometric analysis of the Laplace-Beltrami operator in the discrete domain. We propose global spectral graph wavelet (GSGW) descriptor that is isometric invariant, efficient to compute, and combines the advantages of both low-pass and band-pass filters. We perform experiments on shapes of the carpal bones of ten women and ten men from a publicly-available database of wrist bones. Using one-way multivariate analysis of variance (MANOVA) and permutation testing, we show through extensive experiments that the proposed GSGW framework gives a much better performance compared to the global point signature embedding approach for comparing shapes of the carpal bones across populations.

  13. [Tenotomy of carpal and digital flexor tendons for correction of congenital neuromyodysplasia in a calf].

    PubMed

    Sohrt, J T; Heppelmann, M; Rehage, J; Staszyk, C

    2013-01-01

    In a 7-day-old heifer calf, a bilateral flexural deformity of the forelimbs involving the digital flexor tendons, the suspensory ligament and the ulnar and radial carpal flexor tendons was diagnosed. After 2 weeks of conservative treatment consisting of manual stretching of the legs and the application of splints and wooden blocks, which were glued to the soles and extended beyond the tip of the claws, the right forelimb could be extended sufficiently to allow weight bearing, whereas the left forelimb could be passively extended to only approximately 120°. Therefore, tenotomy of the ulnar carpal flexor tendon, the digital flexor tendons and the suspensory ligament was carried out in the left leg. A support bandage was then applied to the leg for 8 weeks, after which the carpus and fetlock could be completely extended passively. Flexural deformity of the carpus caused by contracture of the carpal flexor tendons was treated by means of a tenotomy of the ulnar carpal flexor tendon proximal to the accessory carpal bone, which allowed preservation of the carpal tunnel and avoided the risk of iatrogenic damage to nerves and the carpal joint capsule.

  14. Implant Fixture Heat Transfer During Abutment Preparation.

    PubMed

    Aleisa, Khalil; Alkeraidis, Abdullah; Al-Dwairi, Ziad Nawaf; Altahawi, Hamdi; Lynch, Edward

    2015-06-01

    The purpose of the study was to evaluate the effect of water flow rate on the heat transmission in implants during abutment preparation using a diamond bur in a high-speed dental turbine. Titanium-alloy abutments (n = 32) were connected to a titanium-alloy implant embedded in an acrylic resin within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each) according to the water flow rate used during the preparation phase. Group 1 had a water flow rate of 24 mL/min, and group 2 had a water flow rate of 40 mL/min. Each abutment was prepared in the axial plane for 1 minute and in the occlusal plane for 1 minute with a coarse tapered diamond bur using a high-speed dental handpiece. Thermocouples embedded at the cervix of the implant surface were used to record the temperature of heat transmission from the abutment preparation. Heat generation was measured at 3 distinct times (immediately and 30 seconds and 60 seconds after the end of preparation). Statistical analyses were carried out using 2-way analysis of variance and the Student t test. Water flow rates (24 mL vs 40 mL) and time interval had no statistically significant effect on the implant's temperature change during the abutment preparation stage (P = .431 and P = .064, respectively). Increasing the water flow rate from 24 to 40 mL/min had no influence on the temperature of the implant fixture recorded during preparation of the abutment.

  15. Comparison Study of Percutaneous Osseointegrated Bone Conduction Device Complications When Using the 9 mm Abutment Versus 6 mm Abutment at Initial Implantation.

    PubMed

    Wise, Sean R; LaRouere, Jacqueline S; Bojrab, Dennis I; LaRouere, Michael J

    2018-04-01

    To assess differences in the incidence, type, and management of complications encountered with implantation of percutaneous osseointegrated bone conduction devices when using a 9 mm abutment versus 6 mm abutment at initial implantation. Retrospective cohort study. One hundred thirty consecutive patients between January 2010 and December 2011 underwent single-stage percutaneous osseointegrated bone conduction device implantation using a 9 or 6 mm abutment. Clinical outcomes assessed for the two groups included the incidence, type, and management of postoperative complications. Abutment size, age, sex, indication for surgery, implant device type, duration of follow-up, and patient comorbidities were evaluated as potential factors affecting outcomes. Average duration of follow-up was 16 months (range 6-29 mo). Postoperative complications occurred in 38 (29.2%) patients. Twenty-four (18.4%) patients experienced minor complications requiring simple, local care; eight (6.1%) patients required in-office procedural intervention; and six (4.6%) patients required revision surgery in the operating room. Implant extrusion occurred in three (2.3%) patients. Eleven (8.5%) patients required placement of a longer abutment. Patients receiving the 6 mm abutment at initial surgery were significantly more likely to encounter a complication requiring in-office procedural intervention or revision surgery (p = 0.001). Minor complications after implantation of percutaneous osseointegrated bone conduction devices are common. The vast majority of these complications are due to localized skin reactions, most of which are readily addressed through local care. Patients receiving the 9 mm abutment during initial implantation are significantly less likely to require in-office procedural intervention or revision surgery postoperatively as compared with those receiving the shorter, 6 mm abutment.

  16. When exactly can carpal tunnel syndrome be considered work-related?

    PubMed

    Falkiner, Sonja; Myers, Stuart

    2002-03-01

    Carpal tunnel syndrome (CTS), compression of the median nerve at the wrist, is the most frequently encountered peripheral entrapment neuropathy. Whilst rates of all other work-related conditions have declined, the number of work-related musculoskeletal disorders (which include CTS) has not changed for the past 9 years in the USA. Median days off work are also highest for CTS: 27 compared to 20 for fractures and 18 for amputations. This results in enormous Workers Compensation and other costs to the community. Awareness of CTS as a disorder associated with repeated trauma at work is now so widespread amongst workers that many have diagnosed themselves before being medically assessed, often by means of the Internet. Surprisingly, however, a definite causal relationship has not yet been established for most occupations. Although the quality of research in this area is generally poor, CTS research studies are being used as the basis for acceptance of Workers Compensation claims, substantial expensive ergonomic workplace change and even workplace closures. The fact that the incidence of work-related musculoskeletal disorders has not changed despite these latter measures would suggest that a causal relationship is not proven and that some resources are being misdirected in CTS prevention and treatment. A literature review of 64 articles on CTS was conducted. This included those articles most frequently cited as demonstrating the relationship between CTS and work. Primary risk factors in the development of CTS are: being a woman of menopausal age, obesity or lack of fitness, diabetes or having a family history of diabetes, osteoarthritis of the carpometacarpal joint of the thumb, smoking, and lifetime alcohol intake. In most cases, work acts as the 'last straw' in CTS causation. Except in the case of work that involves very cold temperatures (possibly in conjunction with load and repetition) such as butchery, work is less likely than demographic and disease

  17. Personal and workplace psychosocial risk factors for carpal tunnel syndrome: a pooled study cohort.

    PubMed

    Harris-Adamson, Carisa; Eisen, Ellen A; Dale, Ann Marie; Evanoff, Bradley; Hegmann, Kurt T; Thiese, Matthew S; Kapellusch, Jay M; Garg, Arun; Burt, Susan; Bao, Stephen; Silverstein, Barbara; Gerr, Fred; Merlino, Linda; Rempel, David

    2013-08-01

    Between 2001 and 2010, six research groups conducted coordinated multiyear, prospective studies of carpal tunnel syndrome (CTS) incidence in US workers from various industries and collected detailed subject-level exposure information with follow-up symptom, physical examination, electrophysiological measures and job changes. This analysis of the pooled cohort examined the incidence of dominant-hand CTS in relation to demographic characteristics and estimated associations with occupational psychosocial factors and years worked, adjusting for confounding by personal risk factors. 3515 participants, without baseline CTS, were followed-up to 7 years. Case criteria included symptoms and an electrodiagnostic study consistent with CTS. Adjusted HRs were estimated in Cox proportional hazard models. Workplace biomechanical factors were collected but not evaluated in this analysis. Women were at elevated risk for CTS (HR=1.30; 95% CI 0.98 to 1.72), and the incidence of CTS increased linearly with both age and body mass index (BMI) over most of the observed range. High job strain increased risk (HR=1.86; 95% CI 1.11 to 3.14), and social support was protective (HR=0.54; 95% CI 0.31 to 0.95). There was an inverse relationship with years worked among recent hires with the highest incidence in the first 3.5 years of work (HR=3.08; 95% CI 1.55 to 6.12). Personal factors associated with an increased risk of developing CTS were BMI, age and being a woman. Workplace risk factors were high job strain, while social support was protective. The inverse relationship between CTS incidence and years worked among recent hires suggests the presence of a healthy worker survivor effect in the cohort.

  18. Diagnostic strategies using physical examination are minimally useful in defining carpal tunnel syndrome in population-based research studies.

    PubMed

    Descatha, A; Dale, A-M; Franzblau, A; Coomes, J; Evanoff, B

    2010-02-01

    We evaluated the utility of physical examination manoeuvres in the prediction of carpal tunnel syndrome (CTS) in a population-based research study. We studied a cohort of 1108 newly employed workers in several industries. Each worker completed a symptom questionnaire, a structured physical examination and nerve conduction study. For each hand, our CTS case definition required both median nerve conduction abnormality and symptoms classified as "classic" or "probable" on a hand diagram. We calculated the positive predictive values and likelihood ratios for physical examination manoeuvres in subjects with and without symptoms. The prevalence of CTS in our cohort was 1.2% for the right hand and 1.0% for the left hand. The likelihood ratios of a positive test for physical provocative tests ranged from 2.0 to 3.3, and those of a negative test from 0.3 to 0.9. The post-test probability of positive testing was <50% for all strategies tested. Our study found that physical examination, alone or in combination with symptoms, was not predictive of CTS in a working population. We suggest using specific symptoms as a first-level screening tool, and nerve conduction study as a confirmatory test, as a case definition strategy in research settings.

  19. Detail, north abutment, from southeast, showing original squared cut stone ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north abutment, from southeast, showing original squared cut stone masonry abutment and portion of non-original concrete apron at west base of abutment - Castle Garden Bridge, Township Route 343 over Bennetts Branch of Sinnemahoning Creek, Driftwood, Cameron County, PA

  20. Effect of Cyclic Loading on Micromotion at the Implant-Abutment Interface.

    PubMed

    Karl, Matthias; Taylor, Thomas D

    2016-01-01

    Cyclic loading may cause settling of abutments mounted on dental implants, potentially affecting screw joint stability and implant-abutment micromotion. It was the goal of this in vitro study to compare micromotion of implant-abutment assemblies before and after masticatory simulation. Six groups of abutments (n = 5) for a specific tissue-level implant system with an internal octagon were subject to micromotion measurements. The implant-abutment assemblies were loaded in a universal testing machine, and an apparatus and extensometers were used to record displacement. This was done twice, in the condition in which they were received from the abutment manufacturer and after simulated loading (100,000 cycles; 100 N). Statistical analysis was based on analysis of variance, two-sample t tests (Welch tests), and Pearson product moment correlation (α = .05). The mean values for micromotion ranged from 33.15 to 63.41 μm and from 30.03 to 42.40 μm before and after load cycling. The general trend toward reduced micromotion following load cycling was statistically significant only for CAD/CAM zirconia abutments (P = .036) and for one type of clone abutment (P = .012), with no significant correlation between values measured before and after cyclic loading (Pearson product moment correlation; P = .104). While significant differences in micromotion were found prior to load cycling, no significant difference among any of the abutment types tested could be observed afterward (P > .05 in all cases). A quantifiable settling effect at the implant-abutment interface seems to result from cyclic loading, leading to a decrease in micromotion. This effect seems to be more pronounced in low-quality abutments. For the implant system tested in this study, retightening of abutment screws is recommended after an initial period of clinical use.

  1. 6. View of east side abutment and wing wall. The ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. View of east side abutment and wing wall. The detail of this abutment and wing wall is the same for the similar abutment treatment at the west side. - Tipp-Elizabeth Road Bridge, Spanning Great Miami River, Tipp City, Miami County, OH

  2. Fracture resistance of zirconia-based implant abutments after artificial long-term aging.

    PubMed

    Alsahhaf, Abdulaziz; Spies, Benedikt Christopher; Vach, Kirstin; Kohal, Ralf-Joachim

    2017-02-01

    To investigate the survival rate, fracture strength, bending moments, loading to fracture and fracture modes of different designs of zirconia abutments after dynamic loading with thermocycling, and compare these values to titanium abutments. A total of 80 abutment samples were divided into 5 test groups of 16 samples in each group. The study included the following groups, "Group 1" CAD/CAM produced all-zirconia abutments, "Group 2" titanium abutments, "Group 3" zirconia-abutments adhesively luted to a titanium base, "Group 4" prefabricated all-zirconia abutments and "Group 5" zirconia-abutments glass soldered to a titanium base. Half the number of samples in each group was exposed to 1.2 million loading cycles (5-years simulation) in the chewing simulator. The samples that survived the artificial aging were later tested for fracture strength in a universal testing machine. The remaining 8 samples of the group were directly tested for fracture strength. All samples exposed to the 5-years artificial aging survived except of six samples in one group (Group 1). The surviving samples were later fracture tested in the universal testing machine. The bending moments (Ncm) values were as follow: Exposed groups: "Group 1" 94.5Ncm; "Group 2" 599.2Ncm; "Group 3" 477.5Ncm; "Group 4" 314.4Ncm; "Group 5" 509.4Ncm. Non-exposed groups: "Group 1" 269.3Ncm; "Group 2" 474.2Ncm; "Group 3" 377.6Ncm; "Group 4" 265.4Ncm; "Group 5" 372.4Ncm. Except in Group 1, the values were higher in the exposed groups, although, statistically there was no difference (p>0.05). The one-piece ZrO2-abutment group (Group 1 and Group 4) exhibited lower values, while the two-piece ZrO2-abutment groups (Group 3 and Group 5) showed similar values and fracture modes like the titanium abutment group. The titanium abutment group showed the highest values of bending moments among all groups. The implant-abutment connection area appeared to influence the bending moment value and the fracture mode of the tested

  3. Effect of extracorporeal shock wave therapy on the treatment of patients with carpal tunnel syndrome.

    PubMed

    Vahdatpour, Babak; Kiyani, Abolghasem; Dehghan, Farnaz

    2016-01-01

    The carpal tunnel syndrome (CTS) is the most common neuropathy. The aim of this study was to evaluate the effect of a new and noninvasive treatment including extracorporeal shock wave therapy (ESWT) in the treatment of CTS. This study is a clinical trial conducted on 60 patients with moderate CTS in selected health centers of Isfahan Medical University from November 2014 to April 2015. Patients with CTS were randomly divided into two groups. Conservative treatment including wrist splint at night for 3 months, consumption of nonsteroidal anti-inflammatory drugs for 2 weeks, and oral consumption of Vitamin B1 for a month was recommended for both groups. The first group was treated with ESWT, one session per week for 4 weeks. Focus probe with 0.05, 0.07, 0.1, and 0.15 energy and shock numbers 800, 900, 1000, and 1100 were used from the first session to the fourth, respectively. The evaluated parameters were assessed before treatment and after 3 and 6 months. Data were analyzed using SPSS version 19, Student's t-test, and Chi-square test. All parameters were significantly decreased in the ESWT group after 3 months. These results remained almost constant after 6 months compared with 3 months after treatment. However, only two parameters considerably improved after 3 months of treatment in the control group. The entire indexes in the control group implicated the regression of results in long-term period. It is recommended to use ESWT as a conservative treatment in patients with CTS.

  4. The Effects of Low Intensity Laser on Clinical and Electrophysiological Parameters of Carpal Tunnel Syndrome

    PubMed Central

    Rayegani, Seyed Mansoor; Bahrami, Mohammad Hasan; Eliaspour, Darisuh; Raeissadat, Seyed Ahmad; Shafi Tabar Samakoosh, Mostafa; Sedihgipour, Leyla; Kargozar, Elham

    2013-01-01

    Introduction: Carpal Tunnel Syndrome (CTS) is the most common type of entrapment neuropathy. Conservative therapy is usually considered as the first step in the management of CTS. Low Level Laser Therapy (LLLT) is among the new physical modalities, which has shown therapeutic effects in CTS. The aim of the present study was to compare the effects of applying LASER and splinting together with splinting alone in patients with CTS. Methods: Fifty patients with mild and moderate CTS who met inclusion criteria were included in this study. The disease was confirmed by electrodiagnostic study (EDx) and clinical findings. Patients were randomly divided into 3 groups. Group A received LLLT and splinting. Group B received sham LLLT+ splinting and group C received only splints. Group A received LLLT (50 mw and 880nm with total dose of 6 joule/cm2). Clinical and EDx parameters were evaluated before and after treatment (3 weeks and 2 months later). Results: Electrophysiologic parameters and clinical findings including CTS provocative tests, Symptoms severity score (SSS), Functional Severity Score (FSS) and Visual Analogue Score (VAS) were improved in all three groups at 3 weeks and 2 months after treatment. No significant changes were noticed between the three groups regarding clinical and EDX parameters. Conclusion: We found no superiority in applying Low Intensity Laser accompanying splinting to traditional treatment which means splinting alone in patients with CTS. However, future studies investigating LLLT with parameters other than the one used in this study may reveal different results in favor of LLLT. PMID:25606328

  5. Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger: an MRI study.

    PubMed

    Martin, Joel R; Paclet, Florent; Latash, Mark L; Zatsiorsky, Vladimir M

    2013-02-01

    Carpal tunnel syndrome is a disorder caused by increased pressure in the carpal tunnel associated with repetitive, stereotypical finger actions. Little is known about in vivo geometrical changes in the carpal tunnel caused by motion at the finger joints and exerting a fingertip force. The hands and forearms of five subjects were scanned using a 3.0 T magnetic resonance imaging scanner. The metacarpophalangeal joint of the index finger was placed in: flexion, neutral and extension. For each joint posture subjects either produced no active force (passive condition) or exerted a flexion force to resist a load (~4.0 N) at the fingertip (active condition). Changes in the radii of curvature, position and transverse plane area of the flexor digitorum profundus tendons at the carpal tunnel level were measured. The radius of curvature of the flexor digitorum profundus tendons, at the carpal tunnel level, was significantly affected by posture of the index finger metacarpophalangeal joint (P<0.05) and the radii was significantly different between fingers (P<0.05). Actively producing force caused a significant shift (P<0.05) in the flexor digitorum profundus tendons in the ventral (palmar) direction. No significant change in the area of an ellipse containing the flexor digitorum profundus tendons was observed between conditions. The results show that relatively small changes in the posture and force production of a single finger can lead to significant changes in the geometry of all the flexor digitorum profundus tendons in the carpal tunnel. Additionally, voluntary force production at the fingertip increases the moment arm of the FDP tendons about the wrist joint. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Creep and shrinkage effects on integral abutment bridges

    NASA Astrophysics Data System (ADS)

    Munuswamy, Sivakumar

    Integral abutment bridges provide bridge engineers an economical design alternative to traditional bridges with expansion joints owing to the benefits, arising from elimination of expensive joints installation and reduced maintenance cost. The superstructure for integral abutment bridges is cast integrally with abutments. Time-dependent effects of creep, shrinkage of concrete, relaxation of prestressing steel, temperature gradient, restraints provided by abutment foundation and backfill and statical indeterminacy of the structure introduce time-dependent variations in the redundant forces. An analytical model and numerical procedure to predict instantaneous linear behavior and non-linear time dependent long-term behavior of continuous composite superstructure are developed in which the redundant forces in the integral abutment bridges are derived considering the time-dependent effects. The redistributions of moments due to time-dependent effects have been considered in the analysis. The analysis includes nonlinearity due to cracking of the concrete, as well as the time-dependent deformations. American Concrete Institute (ACI) and American Association of State Highway and Transportation Officials (AASHTO) models for creep and shrinkage are considered in modeling the time dependent material behavior. The variations in the material property of the cross-section corresponding to the constituent materials are incorporated and age-adjusted effective modulus method with relaxation procedure is followed to include the creep behavior of concrete. The partial restraint provided by the abutment-pile-soil system is modeled using discrete spring stiffness as translational and rotational degrees of freedom. Numerical simulation of the behavior is carried out on continuous composite integral abutment bridges and the deformations and stresses due to time-dependent effects due to typical sustained loads are computed. The results from the analytical model are compared with the

  7. Modeling the cost-benefit of nerve conduction studies in pre-employment screening for carpal tunnel syndrome.

    PubMed

    Evanoff, Bradley; Kymes, Steve

    2010-06-01

    The aim of this study was to evaluate the costs associated with pre-employment nerve conduction testing as a screening tool for carpal tunnel syndrome (CTS) in the workplace. We used a Markov decision analysis model to compare the costs associated with a strategy of screening all prospective employees for CTS and not hiring those with abnormal nerve conduction, versus a strategy of not screening for CTS. The variables included in our model included employee turnover rate, the incidence of CTS, the prevalence of median nerve conduction abnormalities, the relative risk of developing CTS conferred by abnormal nerve conduction screening, the costs of pre-employment screening, and the worker's compensation costs to the employer for each case of CTS. In our base case, total employer costs for CTS from the perspective of the employer (cost of screening plus costs for workers' compensation associated with CTS) were higher when screening was used. Median costs per employee position over five years were US$503 for the screening strategy versus US$200 for a no-screening strategy. A sensitivity analysis showed that a strategy of screening was cost-beneficial from the perspective of the employer only under a few circumstances. Using Monte Carlo simulation varying all parameters, we found a 30% probability that screening would be cost-beneficial. A strategy of pre-employment screening for CTS should be carefully evaluated for yield and social consequences before being implemented. Our model suggests such screening is not appropriate for most employers.

  8. Impact of abutment rotation and angulation on marginal fit: theoretical considerations.

    PubMed

    Semper, Wiebke; Kraft, Silvan; Mehrhof, Jurgen; Nelson, Katja

    2010-01-01

    Rotational freedom of various implant positional index designs has been previously calculated. To investigate its clinical relevance, a three-dimensional simulation was performed to demonstrate the influence of rotational displacements of the abutment on the marginal fit of prosthetic superstructures. Idealized abutments with different angulations (0, 5, 10, 15, and 20 degrees) were virtually constructed (SolidWorks Office Premium 2007). Then, rotational displacement was simulated with various degrees of rotational freedom (0.7, 0.95, 1.5, 1.65, and 1.85 degrees). The resulting horizontal displacement of the abutment from the original position was quantified in microns, followed by a simulated pressure-less positioning of superstructures with defined internal gaps (5 µm, 60 µm, and 100 µm). The resulting marginal gap between the abutment and the superstructure was measured vertically with the SolidWorks measurement tool. Rotation resulted in a displacement of the abutment of up to 157 µm at maximum rotation and angulation. Interference of a superstructure with a defined internal gap of 5 µm placed on the abutment resulted in marginal gaps up to 2.33 mm at maximum rotation and angulation; with a 60-µm internal gap, the marginal gaps reached a maximum of 802 µm. Simulation using a superstructure with an internal gap of 100 µm revealed a marginal gap of 162 µm at abutment angulation of 20 degrees and rotation of 1.85 degrees. The marginal gaps increased with the degree of abutment angulation and the extent of rotational freedom. Rotational displacement of the abutment influenced prosthesis misfit. The marginal gaps between the abutment and the superstructure increased with the rotational freedom of the index and the angulation of the abutment.

  9. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  10. Influence of Four Different Abutment Materials and the Adhesive Joint of Two-Piece Abutments on Cervical Implant Bone and Soft Tissue.

    PubMed

    Mehl, Christian; Gassling, Volker; Schultz-Langerhans, Stephan; Açil, Yahya; Bähr, Telse; Wiltfang, Jörg; Kern, Matthias

    The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue. Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control. The animals were sacrificed 6 months after implant exposure, and the bone-to-implant contact (BIC) area, sulcus depth, the length of the junctional epithelium and the connective tissue, the biologic width, and first cervical BIC-implant shoulder distance were measured using histomorphometry and light and fluorescence microscopy. Overall, 14 implants were lost (22%). At exposure, the implant shoulder-bone distance was 0.6 ± 0.7 mm. Six months later, the bone loss was 2.1 ± 1.2 mm measured histomorphometrically. There was a significant difference between the two measurements (P ≤ .0001). No significant influence could be found between any of the abutment materials with regard to bone loss or soft tissue anatomy (P > .05), with the exception of zirconium dioxide and onepiece titanium abutments when measuring the length of the junctional epithelium (P ≤ .01). The maxilla provided significantly more soft tissue and less bone loss compared with the mandible (P ≤ .02). All tested abutment materials and techniques seem to be comparable with regard to soft tissue properties and the cervical bone level.

  11. Does sensory relearning improve tactile function after carpal tunnel decompression? A pragmatic, assessor-blinded, randomized clinical trial

    PubMed Central

    Jerosch-Herold, C.; Houghton, J.; Miller, L.; Shepstone, L.

    2016-01-01

    Despite surgery for carpal tunnel syndrome being effective in 80%–90% of cases, chronic numbness and hand disability can occur. The aim of this study was to investigate whether sensory relearning improves tactile discrimination and hand function after decompression. In a multi-centre, pragmatic, randomized, controlled trial, 104 patients were randomized to a sensory relearning (n = 52) or control (n = 52) group. A total of 93 patients completed a 12-week follow-up. Primary outcome was the shape-texture identification test at 6 weeks. Secondary outcomes were touch threshold, touch localization, dexterity and self-reported hand function. No significant group differences were seen for the primary outcome (Shape-Texture Identification) at 6 weeks or 12 weeks. Similarly, no significant group differences were observed on secondary outcomes, with the exception of self-reported hand function. A secondary complier-averaged-causal-effects analysis showed no statistically significant treatment effect on the primary outcome. Sensory relearning for tactile sensory and functional deficits after carpal tunnel decompression is not effective. Level of Evidence: II PMID:27402282

  12. The effect of repeated torque tightening on total lengths of implant abutments in different internal implant‒abutment connections.

    PubMed

    Saleh Saber, Fariba; Abolfazli, Nader; Jannatii Ataei, Soheil; Taghizade Motlagh, Mahsa; Gharekhani, Vahede

    2017-01-01

    Background. Since the misfit of crown has an important role in clinical performance of implant-supported prostheses, and due to the impact of the settling effect on misfit, the aim of this study was to investigate the impact of torque forces on the total lengths of narrow and short implant abutments in different internal implant‒abutment connections. Methods. In four different implant‒abutment connections, 8 analog implants with a normal diameter (4 mm) and narrow abutment (4.5 mm) were selected from groups of internal hex, internal octagon, morse hex 6° and morse hex 11°. Each of them was mounted within plaster type IV, and 32 samples were obtained. Then, the amount of vertical displacement was measured by closing the impression copings and applying torques of 20 25 and 30 Ncm. This stage was repeated for the abutment. In the next stage, the resin pattern was built and measurements were performed after applying the torques mentioned. Finally, after making the frame, this stage was repeated, and the settling effect was statistically analyzed with ANOVA. Results. In the stages of impression coping, resin pattern and final prosthesis, HEXAGONE had significantly the highest and OCTAGONE had the lowest rates of settling, and the settling of morse hex 11° and 6° was between them. Conclusion. Octagon implant had significantly the lowest settling in various clinical and laboratory stages by applying different torques.

  13. The effect of repeated torque tightening on total lengths of implant abutments in different internal implant‒abutment connections

    PubMed Central

    Saleh Saber, Fariba; Abolfazli, Nader; Jannatii Ataei, Soheil; Taghizade Motlagh, Mahsa; Gharekhani, Vahede

    2017-01-01

    Background. Since the misfit of crown has an important role in clinical performance of implant-supported prostheses, and due to the impact of the settling effect on misfit, the aim of this study was to investigate the impact of torque forces on the total lengths of narrow and short implant abutments in different internal implant‒abutment connections. Methods. In four different implant‒abutment connections, 8 analog implants with a normal diameter (4 mm) and narrow abutment (4.5 mm) were selected from groups of internal hex, internal octagon, morse hex 6° and morse hex 11°. Each of them was mounted within plaster type IV, and 32 samples were obtained. Then, the amount of vertical displacement was measured by closing the impression copings and applying torques of 20 25 and 30 Ncm. This stage was repeated for the abutment. In the next stage, the resin pattern was built and measurements were performed after applying the torques mentioned. Finally, after making the frame, this stage was repeated, and the settling effect was statistically analyzed with ANOVA. Results. In the stages of impression coping, resin pattern and final prosthesis, HEXAGONE had significantly the highest and OCTAGONE had the lowest rates of settling, and the settling of morse hex 11° and 6° was between them. Conclusion. Octagon implant had significantly the lowest settling in various clinical and laboratory stages by applying different torques. PMID:28748052

  14. A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

    PubMed Central

    Park, Ji-Man; Lee, Jai-Bong; Heo, Seong-Joo

    2014-01-01

    PURPOSE The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ±0.1 µm at 50 points. RESULTS Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment. PMID:24605206

  15. Influence of abutment screw preload on stress distribution in marginal bone.

    PubMed

    Khraisat, Ameen

    2012-01-01

    Changes in an implant assembly after abutment connection might possibly cause deformation in the implant/abutment joint and even in the marginal bone. The aim of this study was to evaluate the influence of abutment screw preload through the implant collar on marginal bone stress without external load application. Models of three implant parts made of titanium (implant, abutment, and abutment screw) and cortical bone were built and positioned with computer-aided design software. Meshing and generation of boundary conditions, loads, and interactions were performed. Each part was meshed independently. The sole load applied to the model was a torque of 32 Ncm on the abutment screw about its axis of rotation. The implant collar was deformed axially after the screw was tightened (3 μm). This deformation resulted in 60 MPa of stress in the marginal bone. Moreover, pressure on the marginal bone in a radial direction was observed. It can be concluded that, without any external load application, abutment screw preload exerts stresses on the implant collar and the marginal bone. These findings should help guide the development of new implant/abutment joint designs that exert less stress on the marginal bone.

  16. Risk factors for carpal tunnel syndrome related to the work organization: a prospective surveillance study in a large working population.

    PubMed

    Petit, Audrey; Ha, Catherine; Bodin, Julie; Rigouin, Pascal; Descatha, Alexis; Brunet, René; Goldberg, Marcel; Roquelaure, Yves

    2015-03-01

    The study aimed to determine the risk factors for incident carpal tunnel syndrome (CTS) in a large working population, with a special focus on factors related to work organization. In 2002-2005, 3710 workers were assessed and, in 2007-2010, 1611 were re-examined. At baseline all completed a self-administered questionnaire about personal/medical factors and work exposure. CTS symptoms and physical examination signs were assessed by a standardized medical examination at baseline and follow-up. The risk of "symptomatic CTS" was higher for women (OR = 2.9 [1.7-5.2]) and increased linearly with age (OR = 1.04 [1.00-1.07] for 1-year increment). Two work organizational factors remained in the multivariate risk model after adjustment for the personal/medical and biomechanical factors: payment on a piecework basis (OR = 2.0, 95% CI 1.1-3.5) and work pace dependent on automatic rate (OR = 1.9, 95% CI 0.9-4.1). Several factors related to work organization were associated with incident CTS after adjustment for potential confounders. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  17. The applicability of PEEK-based abutment screws.

    PubMed

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Effect of intentional abutment disconnection on the micro-movements of the implant-abutment assembly: a 3D digital image correlation analysis.

    PubMed

    Messias, Ana; Rocha, Salomão; Calha, Nuno; Neto, Maria Augusta; Nicolau, Pedro; Guerra, Fernando

    2017-01-01

    Implant-abutment assembly stability is critical for the success of implant-supported rehabilitation. The intentional removal of the prosthetic components may hamper the achievement of the essential stability due to preload reduction in the screw joint and implant-screw mating surface changes. To evaluate the effect of intentional abutment disconnection and reconnection in the stability of internal locking hex implants and corresponding abutments using the method of 3D digital image correlation. Ten conical shape and internal hexagon connection implants were embedded in acrylic resin and assembled to prosthetic abutments with 30 Ncm torque and assigned to two groups: group 1 - tested for static load-bearing capacity at 30° off-axis for two times and group 2 - underwent intentional disconnection and reconnection between tests. Micro-movements were captured with two high-speed photographic cameras and analyzed with video correlation system in three spacial axes U, V and W. Screw abutment and internal implant thread morphology was observed with a field-emission scanning electron microscopy. After the intentional disconnection of the abutment, group 2 showed generally higher maximum displacements for U and V directions. Under 50N load, mean difference was 24.7 μm (P = 0.008) for U direction and -7.7 μm (P = 0.008) for V direction. No significant differences were found for maximum and minimum displacements in the W direction. Mean displacement of the speckle surface presented was statistically different in the two groups (P = 0.016). SEM revealed non-homogenous screw surfaces with scoring on group 2 plus striations and debris in the implant threads. Micro-movements were higher for the group submitted to intentional disconnection and reconnection of the abutment, particularly under average bite forces. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Expanded clinical spectrum of spondylocarpotarsal synostosis syndrome and possible manifestation in a heterozygous father.

    PubMed

    Mitter, Diana; Krakow, Deborah; Farrington-Rock, Claire; Meinecke, Peter

    2008-03-15

    We report on a 5-year-old boy with spondylocarpotarsal synostosis (SCT) syndrome who presents with disproportionate short stature, thoracic scoliosis, pes planus, dental enamel hypoplasia, unilateral conductive hearing loss and mild facial dysmorphisms. Radiographs showed abnormal segmentation of the spine with block vertebrae and carpal synostosis. In addition to the typical phenotype of SCT syndrome, he showed pronounced delay of carpal bone age and bilateral epiphyseal dysplasia of the proximal femora. The patient's father has mild short stature and unilateral hip dysplasia. Molecular studies of the filamin B gene (FLNB) revealed a homozygous mutation in the index patient while both parents were heterozygous for the mutation. In this report we expand the phenotype of SCT syndrome in a patient with a causal FLNB mutation. (c) 2008 Wiley-Liss, Inc.

  20. Two Different Percutaneous Bone-Anchored Hearing Aid Abutment Systems: Comparative Clinical Study.

    PubMed

    Polat, Beldan; İşeri, Mete; Orhan, Kadir Serkan; Yılmazer, Ayça Başkadem; Enver, Necati; Ceylan, Didem; Kara, Ahmet; Güldiken, Yahya; Çomoğlu, Şenol

    2016-04-01

    To compare two different percutaneous bone-anchored hearing aid (BAHA) abutment systems regarding operation time, scar healing, quality of life, implant stability, audiologic results, and complications. The study involves a prospective multi-center clinical evaluation. Thirty-two consecutive patients who had undergone BAHA surgery from January 2011 to January 2013 in two tertiary centers were included in the study. The Glasgow Inventory Benefit Score was used to assess the patients at least 6 months after surgery. The operation time and complications were recorded. Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Holger's classification was used to evaluate skin reactions. The mean length of the operation was 39.2±4 min for standard abutment and 18.3±5.7 min for hydroxyapatite-coated abutment. ISQ scores were significantly better for standard abutment in all tests. The mean total Glasgow Inventory Benefit Score was 39.3±19 for the standard abutment and 46.3±24.5 for the hydroxyapatite-coated abutment groups, but there was no statistical significance between the two groups. There was no difference in audiological improvement between the two groups after surgery. Hydroxyapatite-coated abutment provided a shorter operation time that was significantly different from standard abutment. There were no significant differences between standard abutment and hydroxyapatite-coated abutment regarding audiologic improvement, quality of life, loading time, and complications.

  1. Mechanical resistance of zirconium implant abutments: A review of the literature

    PubMed Central

    Vaquero-Aguilar, Cristina; Torres-Lagares, Daniel; Jiménez-Melendo, Manuel; Gutiérrez-Pérez, José L.

    2012-01-01

    The increase of aesthetic demands, together with the successful outcome of current implants, has renewed interest in the search for new materials with enough mechanical properties and better aesthetic qualities than the materials customarily used in implanto-prosthetic rehabilitation. Among these materials, zirconium has been used in different types of implants, including prosthetic abutments. The aim of the present review is to analyse current scientific evidence supporting the use of this material for the above mentioned purposes. We carried out the review of the literature published in the last ten years (2000 through 2010) of in vitro trials of dynamic and static loading of zirconium abutments found in the databases of Medline and Cochrane using the key words zirconium abutment, fracture resistance, fracture strength, cyclic loading. Although we have found a wide variability of values among the different studies, abutments show favourable clinical behaviour for the rehabilitation of single implants in the anterior area. Such variability may be explained by the difficulty to simulate daily mastication under in vitro conditions. The clinical evidence, as found in our study, does not recommend the use of implanto-prosthetic zirconium abutments in the molar area. Key words: Zirconium abutment, zirconium implant abutment, zirconia abutment, fracture resistance, fracture strength, cyclic loading. PMID:22143702

  2. Severity of Carpal Tunnel Syndrome and Diagnostic Accuracy of Hand and Body Anthropometric Measures

    PubMed Central

    Mondelli, Mauro; Farioli, Andrea; Mattioli, Stefano; Aretini, Alessandro; Ginanneschi, Federica; Greco, Giuseppe; Curti, Stefania

    2016-01-01

    Objective To study the diagnostic properties of hand/wrist and body measures according to validated clinical and electrophysiological carpal tunnel syndrome (CTS) severity scales. Methods We performed a prospective case-control study. For each case, two controls were enrolled. Two five-stage clinical and electrophysiological scales were used to evaluate CTS severity. Anthropometric measurements were collected and obesity indicators and hand/wrist ratios were calculated. Area under the receiver operating characteristic curves (AUC), sensitivity, specificity, and likelihood ratios were calculated separately by gender. Results We consecutively enrolled 370 cases and 747 controls. The wrist-palm ratio, waist-hip-height ratio and waist-stature ratio showed the highest proportion of cases with abnormal values in the severe stages of CTS for clinical and electrophysiological severity scales in both genders. Accuracy tended to increase with CTS severity for females and males. In severe stage, most of the indexes presented moderate accuracy in both genders. Among subjects with severe CTS, the wrist-palm ratio presented the highest AUC for hand measures in the clinical and electrophysiological severity scales both in females (AUC 0.83 and 0.76, respectively) and males (AUC 0.91 and 0.82, respectively). Among subjects with severe CTS, the waist-stature ratio showed the highest AUC for body measures in the clinical and electrophysiological severity scales both in females (AUC 0.78 and 0.77, respectively) and males (AUC 0.84 and 0.76, respectively). The results of waist-hip-height ratio AUC were similar. Conclusions Wrist-palm ratio, waist-hip-height ratio and waist-stature ratio could contribute to support the diagnostic hypothesis of severe CTS that however has to be confirmed by nerve conduction study. PMID:27768728

  3. Personal and workplace psychosocial risk factors for carpal tunnel syndrome: a pooled study cohort

    PubMed Central

    Harris-Adamson, Carisa; Eisen, Ellen A; Dale, Ann Marie; Evanoff, Bradley; Hegmann, Kurt T; Thiese, Matthew S; Kapellusch, Jay M; Garg, Arun; Burt, Susan; Bao, Stephen; Silverstein, Barbara; Gerr, Fred; Merlino, Linda; Rempel, David

    2015-01-01

    Background Between 2001 and 2010, six research groups conducted coordinated multiyear, prospective studies of carpal tunnel syndrome (CTS) incidence in US workers from various industries and collected detailed subject-level exposure information with follow-up symptom, physical examination, electrophysiological measures and job changes. Objective This analysis of the pooled cohort examined the incidence of dominant-hand CTS in relation to demographic characteristics and estimated associations with occupational psychosocial factors and years worked, adjusting for confounding by personal risk factors. Methods 3515 participants, without baseline CTS, were followed-up to 7 years. Case criteria included symptoms and an electrodiagnostic study consistent with CTS. Adjusted HRs were estimated in Cox proportional hazard models. Workplace biomechanical factors were collected but not evaluated in this analysis. Results Women were at elevated risk for CTS (HR=1.30; 95% CI 0.98 to 1.72), and the incidence of CTS increased linearly with both age and body mass index (BMI) over most of the observed range. High job strain increased risk (HR=1.86; 95% CI 1.11 to 3.14), and social support was protective (HR=0.54; 95% CI 0.31 to 0.95). There was an inverse relationship with years worked among recent hires with the highest incidence in the first 3.5 years of work (HR=3.08; 95% CI 1.55 to 6.12). Conclusions Personal factors associated with an increased risk of developing CTS were BMI, age and being a woman. Workplace risk factors were high job strain, while social support was protective. The inverse relationship between CTS incidence and years worked among recent hires suggests the presence of a healthy worker survivor effect in the cohort. PMID:23645610

  4. Primary somatosensory/motor cortical thickness distinguishes paresthesia-dominant from pain-dominant carpal tunnel syndrome.

    PubMed

    Maeda, Yumi; Kettner, Norman; Kim, Jieun; Kim, Hyungjun; Cina, Stephen; Malatesta, Cristina; Gerber, Jessica; McManus, Claire; Libby, Alexandra; Mezzacappa, Pia; Mawla, Ishtiaq; Morse, Leslie R; Audette, Joseph; Napadow, Vitaly

    2016-05-01

    Paresthesia-dominant and pain-dominant subgroups have been noted in carpal tunnel syndrome (CTS), a peripheral neuropathic disorder characterized by altered primary somatosensory/motor (S1/M1) physiology. We aimed to investigate whether brain morphometry dissociates these subgroups. Subjects with CTS were evaluated with nerve conduction studies, whereas symptom severity ratings were used to allocate subjects into paresthesia-dominant (CTS-paresthesia), pain-dominant (CTS-pain), and pain/paresthesia nondominant (not included in further analysis) subgroups. Structural brain magnetic resonance imaging data were acquired at 3T using a multiecho MPRAGE T1-weighted pulse sequence, and gray matter cortical thickness was calculated across the entire brain using validated, automated methods. CTS-paresthesia subjects demonstrated reduced median sensory nerve conduction velocity (P = 0.05) compared with CTS-pain subjects. In addition, cortical thickness in precentral and postcentral gyri (S1/M1 hand area) contralateral to the more affected hand was significantly reduced in CTS-paresthesia subgroup compared with CTS-pain subgroup. Moreover, in CTS-paresthesia subjects, precentral cortical thickness was negatively correlated with paresthesia severity (r(34) = -0.40, P = 0.016) and positively correlated with median nerve sensory velocity (r(36) = 0.51, P = 0.001), but not with pain severity. Conversely, in CTS-pain subjects, contralesional S1 (r(9) = 0.62, P = 0.042) and M1 (r(9) = 0.61, P = 0.046) cortical thickness were correlated with pain severity, but not median nerve velocity or paresthesia severity. This double dissociation in somatotopically specific S1/M1 areas suggests a neuroanatomical substrate for symptom-based CTS subgroups. Such fine-grained subgrouping of CTS may lead to improved personalized therapeutic approaches, based on superior characterization of the linkage between peripheral and central neuroplasticity.

  5. 4. South Elevation Columbia Island Abutment Four; South Elevation ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. South Elevation - Columbia Island Abutment Four; South Elevation - Washington Abutment One - Arlington Memorial Bridge, Spanning Potomac River between Lincoln Memorial & Arlington National Cemetery, Washington, District of Columbia, DC

  6. Influence of the implant abutment types and the dynamic loading on initial screw loosening

    PubMed Central

    Kim, Eun-Sook

    2013-01-01

    PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. PMID:23509006

  7. Carpal tunnel syndrome among laboratory technicians in relation to personal and ergonomic factors at work.

    PubMed

    El-Helaly, Mohamed; Balkhy, Hanan H; Vallenius, Laura

    2017-11-25

    Work-related carpal tunnel syndrome (CTS) has been reported in different occupations, including laboratory technicians, so this study was carried out to determine the prevalence and the associated personal and ergonomic factors for CTS among laboratory technicians. A cross-sectional study was conducted among 279 laboratory technicians at King Fahd Hospital, Saudi Arabia, who filled in a self-administered questionnaire, including questions regarding their demographic criteria, occupational history, job tasks, workplace tools, ergonomic factors at work, and symptoms suggestive of CTS. Physical examinations and electrodiagnostic studies were carried out for those who had symptoms suggestive of CTS to confirm the diagnosis. Univariate and multivariate analysis were performed for both personal and physical factors in association with confirmed CTS among laboratory technicians. The prevalence of CTS among the laboratory technicians was 9.7% (27/279). The following were the statistically significant risk factors for CTS among them: gender (all cases of CTS were female, P=0.00), arm/hand exertion (OR: 7.96; 95% CI: 1.84-34.33), pipetting (OR: 7.27; 95% CI: 3.15-16.78), repetitive tasks (OR: 4.60; 95% CI: 1.39-15.70), using unadjustable chairs or desks (OR: 3.35; 95% CI: 1.23-9.15), and working with a biosafety cabinet (OR: 2.49; 95% CI: 1.11-5.59). CTS cases had significant longer work duration (17.9 ± 5.6 years) than CTS non-case (11.5 ± 7.4 yeas) with low OR (1.108). This study demonstrates some personal and ergonomic factors associated with CTS among the laboratory technicians, including female gender, arm/hand exertion, pipetting, repetitive tasks, working with a biosafety cabinet, and an unadjusted workstation.

  8. Waist circumference and waist-to-hip ratio in carpal tunnel syndrome: a case-control study.

    PubMed

    Mondelli, Mauro; Aretini, Alessandro; Ginanneschi, Federica; Greco, Giuseppe; Mattioli, Stefano

    2014-03-15

    The association between carpal tunnel syndrome (CTS) and high body mass index (BMI) and some hand measures is well known. No study has been specifically focused on waist circumference (WC) and waist-to-hip-ratio (WHR). The aim of this prospective case-control study is to evaluate the association between CTS and WC, WHR and other body and hand anthropometric measures. We consecutively enrolled one "idiopathic" CTS case for two controls in 3 outpatient electromyography labs. The main anthropometric measures were BMI, WC, WHR, wrist ratio (WR) and hand ratio (HR). We performed univariate and multivariate analyses. Female cases and controls were 250 and 474 and male cases and controls were 120 and 273, respectively. At univariate analysis there were differences in many anthropometric measures between cases and controls. At multivariate logistic regression analyses high BMI, WC and WHR and abnormal HR and WR were independent risk factors for CTS. Crossing two categories between BMI, WC and WHR, the overweight subjects, especially females, were at risk only if they had very high WC or high WHR. The risk increased if they were obese. High WC/WHR doubles the risk of CTS, the risk further increased if overweight/obese subjects have also very high WC or high WHR. The obese subjects were always at risk regardless of WC and WHR values. Metabolic causes of this association with CTS were hypothesised. BMI is not the only and most powerful body predictor of "idiopathic" CTS, but also WHR and WC should be considered. These measures may not be interchangeable and it may be desirable to consider the utility of their joint use. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Experimental research on the relationship between fit accuracy and fracture resistance of zirconia abutments.

    PubMed

    Sui, Xinxin; Wei, Huasha; Wang, Dashan; Han, Yan; Deng, Jing; Wang, Yongliang; Wang, Junjun; Yang, Jianjun

    2014-10-01

    The purpose of the study was to investigate the correlation between fit accuracy and fracture resistance of zirconia abutments, as well as its feasibility for clinical applications. Twenty self-made zirconia abutments were tested with 30 Osstem GSII implants. First, 10 Osstem GSII implants were cut into two parts along the long axis and assembled with the zirconia abutments. The microgaps between the implants and the zirconia abutments were measured under a scanning electron microscope. Second, the zirconia abutments were assembled with 20 un-cut implants and photographed before and after being fixed with a central screw of 30-Ncm torque. The dental films were measured by Digora for Windows 2.6 software. Then the fracture resistance of zirconia abutments was measured using the universal testing machine at 90°. All results were analyzed using SPSS13.0 software. The average internal-hexagon microgaps between the implants and zirconia abutments were 19.38±1.34μm. The average Morse taper microgap in the implant-abutment interface was 17.55±1.68μm. The dental film showed that the Morse taper gap in the implant-abutment interface disappeared after being fixed with a central screw of 30-Ncm torque, and the average moving distance of the zirconia abutments to the implants was 0.19±0.02mm. The average fracture resistance of zirconia abutments was 282.93±17.28N. The internal-hexagon microgap between the implants and zirconia abutments was negatively related to the fracture resistance of the abutments (r1=-0.97, p<0.01). The Morse taper microgap in the implant-abutment interface was negatively related to the fracture resistance of the abutments (r2=-0.84, p<0.01). The microgap between implant and abutment was negatively related to the fracture resistance of the abutment, while the internal-hexagon microgap has better correlation than the Morse taper microgap. The closure of microgap is helpful to improve the fracture resistance of zirconia abutments. The fracture

  10. Radiographic signs of static carpal instability with distal end radius fractures: is current treatment adequate?

    PubMed

    Bunker, D L J; Pappas, G; Moradi, P; Dowd, M B

    2012-01-01

    Patients presenting with distal end radius fractures may have concomitant carpal instability due to disruption of the scapholunate ligament. This study examined the incidence of static radiographic signs of carpal instability in patients with distal radial fractures before and after fracture treatment. We performed a retrospective radiographic study of 141 patients presenting to Central Middlesex Hospital, London between January 2002-May 2004 with distal end radius fractures. We used abnormal scapholunate angle as the primary indicator of possible carpal dissociation. Abnormal scapholunate angles were noted in 39% of patients at presentation and 35% of patients after treatment with no statistically significant intra-patient variability. Persistent static radiographic signs of carpal instability are high in this subset of patients. The long-term morbidity of persistent wrist instability may be avoided by early radiological diagnosis with clinical correlation to identify carpal ligament injuries and initiate treatment that addresses both the bony and ligamentous components of the injury.

  11. Quality measures for the diagnosis and non-operative management of carpal tunnel syndrome in occupational settings.

    PubMed

    Nuckols, Teryl; Harber, Philip; Sandin, Karl; Benner, Douglas; Weng, Haoling; Shaw, Rebecca; Griffin, Anne; Asch, Steven

    2011-03-01

    Providing higher quality medical care to workers with occupationally associated carpal tunnel syndrome (CTS) may reduce disability, facilitate return to work, and lower the associated costs. Although many workers' compensation systems have adopted treatment guidelines to reduce the overuse of unnecessary care, limited attention has been paid to ensuring that the care workers do receive is high quality. Further, guidelines are not designed to enable objective assessments of quality of care. This study sought to develop quality measures for the diagnostic evaluation and non-operative management of CTS, including managing occupational activities and functional limitations. Using a variation of the well-established RAND/UCLA Appropriateness Method, we developed draft quality measures using guidelines and literature reviews. Next, in a two-round modified-Delphi process, a multidisciplinary panel of 11 U.S. experts in CTS rated the measures on validity and feasibility. Of 40 draft measures, experts rated 31 (78%) valid and feasible. Nine measures pertained to diagnostic evaluation, such as assessing symptoms, signs, and risk factors. Eleven pertain to non-operative treatments, such as the use of splints, steroid injections, and medications. Eleven others address assessing the association between symptoms and work, managing occupational activities, and accommodating functional limitations. These measures will complement existing treatment guidelines by enabling providers, payers, policymakers, and researchers to assess quality of care for CTS in an objective, structured manner. Given the characteristics of previous measures developed with these methods, greater adherence to these measures will probably lead to improved patient outcomes at a population level.

  12. Can widespread hypersensitivity in carpal tunnel syndrome be substantiated if neck and arm pain are absent?

    PubMed

    Schmid, A B; Soon, B T C; Wasner, G; Coppieters, M W

    2012-02-01

    Recent studies demonstrated that patients with carpal tunnel syndrome (CTS) have signs of thermal and mechanical hyperalgesia in extra-median territories suggesting an involvement of central pain mechanisms. As previous studies included patients with shoulder/arm symptoms or neck pain, a potential influence of these coexisting disorders cannot be excluded. This study therefore evaluated whether widespread sensory changes (hypoesthesia or hyperalgesia) are present in patients with unilateral CTS in the absence of coexisting disorders. Twenty-six patients with unilateral CTS with symptoms localised to their hand and 26 healthy controls participated in the study. A comprehensive quantitative sensory testing (QST) protocol including thermal and mechanical detection and pain thresholds was performed over the hands (median, ulnar and radial innervation area), lateral elbows, neck and tibialis anterior muscle. Patients with CTS demonstrated thermal and mechanical hypoesthesia in the hand but not at distant sites. Thermal or mechanical hyperalgesia was not identified at any location with traditional QST threshold testing. However, patients with CTS rated the pain during thermal pain testing significantly higher than healthy participants. This was especially apparent for heat pain ratings which were elevated not only in the affected hand but also in the neck and tibialis anterior muscle. In conclusion, CTS alone in the absence of coexisting neck and arm pain does not account for sensory changes outside the affected hand as determined by traditional QST threshold testing. Elevated pain ratings may however be an early indication of central pain mechanisms. © 2011 European Federation of International Association for the Study of Pain Chapters.

  13. A syndrome of dislocated hips and radial heads, carpal coalition, and short stature in Puerto Rican children.

    PubMed

    Steel, H H; Piston, R W; Clancy, M; Betz, R R

    1993-02-01

    An orthopaedic syndrome that apparently had not been reported previously was identified in twenty-three children. Characteristics shared by all twenty-three children included Hispanic descent, residence in Puerto Rico, bilateral dislocation of the hip, dislocated radial heads, short stature, and other osseous anomalies. Twelve dislocated hips in six patients were not treated. All of these hips were functioning satisfactorily at the time of the review, but only four of the children had reached skeletal maturity. Sixteen hips in eight patients remained reduced after closed reduction. Of these eight patients, the four who were skeletally immature at the time of the review had a satisfactory result, and the four who were skeletally mature had an unsatisfactory result because of discomfort or fibrous ankylosis. Eighteen hips in nine patients were treated with a reduction augmented by some form of operation. All of these hips redislocated. Of the forty-six elbows in the twenty-three children, thirty-three were dislocated, as seen clinically and radiographically; eight were normal, both clinically and radiographically; and there was dysplasia at the radiocapitellar articulation of the remaining five. Twenty of the twenty-three children were found to have carpal coalitions. Fourteen children had scoliosis, and five of them were managed with spinal arthrodesis and correction. Three patients had an anomaly of the cervical spine, with one deformity causing symptoms and signs that were treated with decompression. Eight patients had talipes cavus bilaterally, which was not treated.

  14. Carpal tunnel syndrome and computer exposure at work in two large complementary cohorts.

    PubMed

    Mediouni, Z; Bodin, J; Dale, A M; Herquelot, E; Carton, M; Leclerc, A; Fouquet, N; Dumontier, C; Roquelaure, Y; Evanoff, B A; Descatha, A

    2015-09-09

    The boom in computer use and concurrent high rates in musculoskeletal complaints and carpal tunnel syndrome (CTS) among users have led to a controversy about a possible link. Most studies have used cross-sectional designs and shown no association. The present study used longitudinal data from two large complementary cohorts to evaluate a possible relationship between CTS and the performance of computer work. The Cosali cohort is a representative sample of a French working population that evaluated CTS using standardised clinical examinations and assessed self-reported computer use. The PrediCTS cohort study enrolled newly hired clerical, service and construction workers in several industries in the USA, evaluated CTS using symptoms and nerve conduction studies (NCS), and estimated exposures to computer work using a job exposure matrix. During a follow-up of 3-5 years, the association between new cases of CTS and computer work was calculated using logistic regression models adjusting for sex, age, obesity and relevant associated disorders. In the Cosali study, 1551 workers (41.8%) completed follow-up physical examinations; 36 (2.3%) participants were diagnosed with CTS. In the PrediCTS study, 711 workers (64.2%) completed follow-up evaluations, whereas 31 (4.3%) had new cases of CTS. The adjusted OR for the group with the highest exposure to computer use was 0.39 (0.17; 0.89) in the Cosali cohort and 0.16 (0.05; 0.59) in the PrediCTS cohort. Data from two large cohorts in two different countries showed no association between computer work and new cases of CTS among workers in diverse jobs with varying job exposures. CTS is far more common among workers in non-computer related jobs; prevention efforts and work-related compensation programmes should focus on workers performing forceful hand exertion. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Functional sensibility assessment. Part II: Effects of sensory improvement on precise pinch force modulation after transverse carpal tunnel release.

    PubMed

    Hsu, Hsiu-Yun; Kuo, Li-Chieh; Chiu, Haw-Yen; Jou, I-Ming; Su, Fong-Chin

    2009-11-01

    Patients with median nerve compression at the carpal tunnel often have poor sensory afferents. Without adequate sensory modulation control, these patients frequently exhibit clumsy performance and excessive force output in the affected hand. We analyzed precision grip function after the sensory recovery of patients with carpal tunnel syndrome (CTS) who underwent carpal tunnel release (CTR). Thirteen CTS patients were evaluated using a custom-designed pinch device and conventional sensory tools before and after CTR to measure sensibility, maximum pinch strength, and anticipated pinch force adjustments to movement-induced load fluctuations in a pinch-holding-up activity. Based on these tests, five force-related parameters and sensory measurements were used to determine improvements in pinch performance after sensory recovery. The force ratio between the exerted pinch force and maximum load force of the lifting object was used to determine pinch force coordination and to prove that CTR enabled precision motor output. The magnitude of peak pinch force indicated an economic force output during manipulations following CTR. The peak pinch force, force ratio, and percentage of maximum pinch force also demonstrated a moderate correlation with the Semmes-Weinstein test. Analysis of these tests revealed that improved sensory function helped restore patients' performance in precise pinch force control evaluations. These results suggest that sensory information plays an important role in adjusting balanced force output in dexterous manipulation. (c) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Comparison of Customized Abutments Made from Titanium and a Machinable Precious Alloy.

    PubMed

    Lee, Jee-Ho; Park, Ji-Man; Park, Eun-Jin; Koak, Jai-Young; Kim, Seong-Kyun; Heo, Seong-Joo

    2016-01-01

    To investigate the clinical usefulness, a customized abutment produced with the Pd-Ag-In alloy was compared with a customized abutment produced with the conventional titanium alloy for discoloration and mechanical accuracy. Discoloration and resistance to corrosion of the Pd-Ag-In alloy were evaluated using chemical solutions. Marginal adaptation of internal-type implants and abutments was compared using 10 titanium abutments and 10 Pd-Ag-In abutments using a surface measuring system. A detorque test was performed on 12 implant-abutment complexes of each control and experimental group to investigate screw joint stability. Cyclic loading simulating a human's mastication movement for 1 year was applied after 30 Ncm initial tightening, and the removal torque was measured using a digital torque gauge. The noninferiority test was conducted to compare the Pd-Ag-In alloy with a titanium abutment with a 10% margin. The Pd-Ag-In alloy had a warm yellow color and displayed stable resistance to discoloration and corrosion, resulting in an advantageous esthetic property. When compared to the titanium alloy, it did not show noninferiority with respect to the gap between the implant and the abutment; the gap was approximately 13.3 μm on average, which was not significantly different from those observed in previous studies. After long-term use, it displayed statistically significant noninferiority in the removal torque value compared to the titanium group. The Pd-Ag-In alloy-based customized abutment had good mechanical properties of the implant-abutment complex as well as a superior esthetic property, and can provide favorable outcomes in anterior implant restoration.

  17. Comparison of fracture strength and failure mode of different ceramic implant abutments.

    PubMed

    Elsayed, Adham; Wille, Sebastian; Al-Akhali, Majed; Kern, Matthias

    2017-04-01

    The whitish color of zirconia (ZrO 2 ) abutments offers favorable esthetics compared with the grayish color of titanium (Ti) abutments. Nonetheless, ZrO 2 has greater opacity, making it difficult to achieve natural tooth color. Therefore, lithium disilicate (LaT) abutments have been suggested to replace metal abutments. The purpose of this in vitro study was to evaluate the fracture strength and failure mode of single-tooth implant restorations using ZrO 2 and LaT abutments, and to compare them with titanium (Ti) abutments. Five different types of abutments, Ti; ZrO 2 with no metal base; ZrO 2 with a metal base (ZrT); LaT; and LaT combination abutment and crown (LcT) were assembled on 40 Ti implants and restored with LaT crowns. Specimens were subjected to quasistatic loading using a universal testing machine, until the implant-abutment connection failed. As bending of the metal would be considered a clinical failure, the values of force (N) at which the plastic deformation of the metal occurred were calculated, and the rate of deformation was analyzed. Statistical analysis was done using the Mann-Whitney U test (α=.05). Group ZrO 2 revealed the lowest resistance to failure with a mean of 202 ±33 N. Groups ZrT, LaT, and LaC withstood higher forces without fracture or debonding of the ceramic suprastructure, and failure was due to deformation of metal bases, with no statistically significant differences between these groups regarding the bending behavior. Within the limitations of this in vitro study, it was concluded that LaT abutments have the potential to withstand the physiological occlusal forces that occur in the anterior region and that ZrO 2 abutments combined with Ti inserts have much higher fracture strength than pure ZrO 2 abutments. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Prosthetic management of malpositioned implant using custom cast abutment

    PubMed Central

    Chatterjee, Aishwarya; Ragher, Mallikarjuna; Patil, Sanket; Chatterjee, Debopriya; Dandekeri, Savita; Prabhu, Vishnu

    2015-01-01

    Two cases are reported with malpositioned implants. Both the implants were placed 6–7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants. PMID:26538957

  19. Bacterial adhesion affinities of various implant abutment materials.

    PubMed

    Yamane, Koichi; Ayukawa, Yasunori; Takeshita, Toru; Furuhashi, Akihiro; Yamashita, Yoshihisa; Koyano, Kiyoshi

    2013-12-01

    To investigate bacterial adhesion to various abutment materials. Thirty volunteers participated in this study. Resin splints were fabricated, and five types of disks were fabricated from pure titanium, gold-platinum alloy, zirconia, alumina, and hydroxyapatite with uniform surface roughness and attached to the buccal surface of each splint. After 4 days of use by the subjects, the plaque accumulated on the disk surfaces was analyzed. The bacterial community structure was evaluated using 16S rRNA gene profiling with terminal restriction fragment length polymorphism analysis. The total bacterial count on each disk was estimated using quantitative polymerase chain reaction. Terminal restriction fragment length polymorphism profiles were more similar between tested materials than between subjects, suggesting that the bacterial community structures on the abutment material were influenced more by the individuals than by the type of material. However, the total number of bacteria attached to a disk was significantly different among five materials (P < 0.001, Brunner-Langer test for longitudinal data). Fewer bacteria were attached to the gold-platinum alloy than to the other materials. Gold-platinum alloy appears to be useful material for abutments when considering the accumulation of plaque. However, alternative properties of the abutment material, such as effects on soft tissue healing, should also be taken into consideration when choosing an abutment material. © 2012 John Wiley & Sons A/S.

  20. Esthetic abutment design for angulated screw channels: A technical report.

    PubMed

    Sakamoto, Satoshi; Ro, Munehiko; Al Ardah, Aladdin; Goodacre, Charles

    2017-11-15

    Angulated screw channel system abutments (ASCs) have recently been introduced to address the problem with visible screw access that may compromise esthetics. ASCs allow the screw access to be modified up to 25 degrees relative to the implant axis. However, a widened channel, which may cause thinning of the facial ceramic, is needed at the implant screw head to allow for proper engagement of the screwdriver. This technical report introduces a custom titanium insert design, the Satoshi Sakamoto (SS) abutment. The SS abutment consists of a custom titanium metal insert and zirconia coping in which the access hole is located in an esthetic position with an ASC system. The SS abutment results in a crown with more normal crown dimensions that also provides more space for the soft tissues. This SS abutment design allows clinicians to obtain screw-retained restorations with optimal esthetics and mechanical strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Application of reverse engineering in the production of individual dental abutments.

    NASA Astrophysics Data System (ADS)

    Yunusov, A. V.; Kashapov, R. N.; Kashapov, L. N.; Statsenko, E. O.

    2017-09-01

    The purpose of the research is to develop a method of manufacturing individual dental abutments for a variety of dental implants. System of industrial X-ray microtomography Phoenix V|tome|X S 240 has been applied for creation of highly accurate model of the dental abutment. Scanning of dental abutment and the optimization of model was produced. The program of milling the individual abutment with a standard conical neck of hexagon was produced for the five-axis milling machine imes - icore 450i from the materials titanium and zirconium oxide.

  2. Critical bending moment of four implant-abutment interface designs.

    PubMed

    Lee, Frank K; Tan, Keson B; Nicholls, Jack I

    2010-01-01

    Critical bending moment (CBM), defined as the bending moment at which the external nonaxial load applied overcomes screw joint preload and causes loss of contact between the mating surfaces of the implant screw joint components, was measured for four different implants and their single-tooth replacement abutments. CBM at the implant-abutment screw joint for four implant-abutment test groups was measured in vitro at 80%, 100%, and 120% of the manufacturers' recommended torque levels. Regular-platform implants with their corresponding single-tooth abutments were used. Microstrain was measured while known loads were applied to the abutment at known distances from the implant-abutment interface. Strain instrumentation was used to record the strain data dynamically to determine the point of gap opening. All torque applications and strain measurements were repeated five times for the five samples in each group. For the Branemark/CeraOne assemblies, the mean CBMs were 72.14 Ncm, 102.21 Ncm, and 119.13 Ncm, respectively, at 80%, 100%, and 120% of the manufacturer's recommended torque. For the Replace/Easy assemblies, mean CBMs were 86.20 Ncm, 109.92 Ncm, and 120.93 Ncm; for the Biomet 3i/STA assemblies, they were 67.97 Ncm, 83.14 Ncm, and 91.81 Ncm; and for the Lifecore/COC assemblies, they were 58.32 Ncm, 76.79 Ncm, and 78.93 Ncm. Two-way analysis of variance revealed significant effects for the test groups and torque levels. Subsequent tests confirmed that significant differences existed between test groups and torque levels. The results appear to confirm the primary role of the compressive preload imparted by the abutment screw in maintaining screw joint integrity. CBM was found to differ among implant systems and torque levels. Torque levels recommended by the manufacturer should be followed to ensure screw joint integrity.

  3. Surgical Approach and Anesthetic Modality for Carpal Tunnel Release: A Nationwide Database Study With Health Care Cost Implications.

    PubMed

    Foster, Brock D; Sivasundaram, Lakshmanan; Heckmann, Nathanael; Cohen, Jeremiah R; Pannell, William C; Wang, Jeffrey C; Ghiassi, Alidad

    2017-03-01

    Background: Carpal tunnel release (CTR) is commonly performed for carpal tunnel syndrome once conservative treatment has failed. Operative technique and anesthetic modality vary by surgeon preference and patient factors. However, CTR practices and anesthetic trends have, to date, not been described on a nationwide scale in the United States. Methods: The PearlDiver Patient Records Database was used to search Current Procedural Terminology codes for elective CTR from 2007 to 2011. Anesthetic modality (eg, general and regional anesthesia vs local anesthesia) and surgical approach (eg, endoscopic vs open) were recorded for this patient population. Cost analysis, patient demographics, regional variation, and annual changes in CTR surgery were evaluated. Results: We identified 86 687 patients who underwent carpal tunnel surgery during this 5-year time period. In this patient sample, 80.5% of CTR procedures were performed using general or regional anesthesia, compared with 19.5% of procedures performed using local anesthesia; 83.9% of all CTR were performed in an open fashion, and 16.1% were performed using an endoscopic technique. Endoscopic surgery was on average $794 more expensive than open surgery, and general or regional anesthesia was $654 more costly than local anesthesia. Conclusions: In the United States, open CTR under local anesthesia is the most cost-effective way to perform a CTR. However, only a small fraction of elective CTR procedures are performed with this technique, representing a potential area for significant health care cost savings. In addition, regional and age variations exist in procedure and anesthetic type utilized.

  4. Comparison of observed and predicted abutment scour at selected bridges in Maine.

    DOT National Transportation Integrated Search

    2008-01-01

    Maximum abutment-scour depths predicted with five different methods were compared to : maximum abutment-scour depths observed at 100 abutments at 50 bridge sites in Maine with a : median bridge age of 66 years. Prediction methods included the Froehli...

  5. The influence of abutment angulation on screw loosening of implants in the anterior maxilla.

    PubMed

    Ha, Chun-Yeo; Lim, Yung-Jun; Kim, Myung-Joo; Choi, Jung-Han

    2011-01-01

    This study compared the removal torque values (RTVs) of different abutments (straight, angled, and gold premachined UCLA-type) in external- and internal-hex implants after dynamic cyclic loading with the clinical situation of the anterior maxilla simulated. An ideal cast of a maxilla with a missing right central incisor was fabricated in dental stone, and an implant analog was embedded in this model at a 15-degree angle labial to the long axis of the left central incisor. Thirty external-hex and 30 internal-hex implants were used. A total of 10 straight abutments, 10 angled abutments, and 10 gold premachined UCLA-type abutments of each system and 60 abutment screws were tested. Initial RTVs were measured after each assembly was tightened to 30 Ncm. Straight abutments and angled abutments were prepared and gold-premachined UCLA-type abutments were waxed and cast with low-fusing gold alloy for the central incisor. RTVs were then measured again. After each assembly was tightened, a metal crown was temporarily cemented. After cyclic loading of 20 to 200 N was applied 1 million times, RTVs were measured for a third time. Statistical analysis (alpha = .05) was performed to evaluate the results. The angled abutment group showed significantly higher RTVs than the straight abutment and gold premachined UCLA-type abutment groups in external-hex implants. However, no significant difference in RTVs was found among abutments in internal-hex implants. The time of analysis of RTV was found to significantly influence mean RTVs. Mean RTVs of external- and internal-hex implants showed significant differences. Within the limitations of this study, there were significant differences in RTVs among different abutment groups in external-hex implants. There were no significant differences in RTVs among different abutment groups in internal-hex implants.

  6. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    PubMed

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  7. Influence of reverse torque values in abutments with or without internal hexagon indexes.

    PubMed

    Cerutti-Kopplin, Daiane; Rodrigues Neto, Dimas João; Lins do Valle, Accácio; Pereira, Jefferson Ricardo

    2014-10-01

    The mechanical stability of the implant-abutment connection is of fundamental importance for successful implant-supported restorations. Therefore, understanding removal torque values is essential. The purpose of this study was to evaluate the reverse torque values of indexed and nonindexed abutments of the Morse Taper system. Twelve Morse taper implants with their respective abutments were divided into 2 groups (n=6): group NI, nonindexed abutments; and group IN, indexed abutments. Each abutment received a sequence of 2 consecutive torques for insertion (15 Ncm) at an interval of 10 minutes, and 1 reverse torque, all measured with a digital torque wrench. The Student t test with a 5% significance level was used to evaluate the data. Statistical analysis showed no significant difference in reverse torque values between nonindexed and indexed abutments (P=.57). When comparing insertion torque and reverse torque values between the groups, group NI presented a mean torque loosening percentage of 8% (P=.013), whereas group IN presented a loosening of 15.33% (P<.001). The use of indexed abutments for the Morse taper system presented similar biomechanical stability when compared with nonindexed abutments, both with a significant reduction in reverse torque values. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Performance of conical abutment (Morse Taper) connection implants: a systematic review.

    PubMed

    Schmitt, Christian M; Nogueira-Filho, Getulio; Tenenbaum, Howard C; Lai, Jim Yuan; Brito, Carlos; Döring, Hendrik; Nonhoff, Jörg

    2014-02-01

    In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc.

  9. Effects of Repeated Screw Tightening on Implant Abutment Interfaces in Terms of Bacterial and Yeast Leakage in Vitro: One-Time Abutment Versus the Multiscrewing Technique.

    PubMed

    Calcaterra, Roberta; Di Girolamo, Michele; Mirisola, Concetta; Baggi, Luigi

    2016-01-01

    Screw loosening can damage the interfaces of implant components, resulting in susceptibility to contamination of the internal parts by microorganisms. The aim of this study was to investigate the impact of abutment screw retightening on the leakage of two different types of bacteria, Streptococcus sanguinis and Fusobacterium nucleatum, and of the yeast Candida albicans. Two types of implant-abutment systems with tube-in-tube interfaces were tested. Groups A and B each used a different type of system that consisted of 20 different pieces that were assembled according to the manufacturer's torque recommendations; four samples in each group were closed just one time, four samples three times, four samples five times, four samples seven times, and four samples nine times. The implants of groups A and B were contaminated with 0.1 μL of microbial solution just before being assembled for the last time to minimize the possibility of contamination. Results showed a direct correlation between the number of colony-forming units grown in the plates and the closing/opening cycles of the implant-abutment systems. Within the limitations of this study, the results indicate the possibility that repeated closing/opening cycles of the implant-abutment unit may influence bacterial/yeast leakage, most likely as a consequence of decreased precision of the coupling between the abutment and the internal part of the dental implant. These findings suggest that a one-time abutment technique may avoid microbiologic leakage in cases of implant-abutment systems with tube-in-tube interfaces.

  10. Strain analysis of 9 different abutments for cement-retained crowns on an internal hexagonal implant.

    PubMed

    Salaita, Louai G; Yilmaz, Burak; Seidt, Jeremy D; Clelland, Nancy L; Chien, Hua-Hong; McGlumphy, Edwin A

    2017-08-01

    Many aftermarket abutments for cement-retained crowns are available for the tapered screw-vent implant. Aftermarket abutments vary widely, from stock to custom abutments and in materials such as zirconia, titanium, or a combination of the two. How these aftermarket abutments perform under occlusal loads with regard to strain distribution is not clear. The purpose of this in vitro study was to measure and compare the different strains placed upon the bone around implants by 9 different abutments for cement-retained crowns on an implant with an internal hexagonal platform. Nine 4.1×11.5-mm tapered screw-vent implants were placed into a 305×51×8-mm resin block for strain measurements. Five abutment specimens of each of the 9 different abutments (N=45) were evaluated with 1 of the 9 implants. Monolithic zirconia crowns were then fabricated for each of the 9 different abutments, the crowns were cyclically loaded (maximum force 225 N) at 30 degrees, twice at a frequency of 2 Hz, and the strain was measured and recorded. The strain to the resin block was determined using a 3-dimensional digital image correlation (3D DIC) technique. Commercial image correlation software was used to analyze the strain around the implants. Data for maximal and minimal principal strains were compared using analysis of variance with a Tukey-Kramer post hoc test (α=.05). Strain measurements showed no significant differences among any of the abutments for minimal (compression) principal strains (P>.05). For maximal (tensile) principal strains, the zirconia abutment showed the highest, and the patient-specific abutment showed the second-highest strain around the implant, with the zirconia being significantly greater than all abutments, with the exception of the patient-specific abutment, and the patient-specific abutment being significantly greater than the straight contoured abutment in titanium and also zirconia (P<.05). The name brand patient specific titanium and Atlantis zirconia

  11. Carpal tunnel syndrome among laboratory technicians in relation to personal and ergonomic factors at work

    PubMed Central

    El-Helaly, Mohamed; Balkhy, Hanan H.; Vallenius, Laura

    2017-01-01

    Objectives: Work-related carpal tunnel syndrome (CTS) has been reported in different occupations, including laboratory technicians, so this study was carried out to determine the prevalence and the associated personal and ergonomic factors for CTS among laboratory technicians. Methods: A cross-sectional study was conducted among 279 laboratory technicians at King Fahd Hospital, Saudi Arabia, who filled in a self-administered questionnaire, including questions regarding their demographic criteria, occupational history, job tasks, workplace tools, ergonomic factors at work, and symptoms suggestive of CTS. Physical examinations and electrodiagnostic studies were carried out for those who had symptoms suggestive of CTS to confirm the diagnosis. Univariate and multivariate analysis were performed for both personal and physical factors in association with confirmed CTS among laboratory technicians. Results: The prevalence of CTS among the laboratory technicians was 9.7% (27/279). The following were the statistically significant risk factors for CTS among them: gender (all cases of CTS were female, P=0.00), arm/hand exertion (OR: 7.96; 95% CI: 1.84-34.33), pipetting (OR: 7.27; 95% CI: 3.15-16.78), repetitive tasks (OR: 4.60; 95% CI: 1.39-15.70), using unadjustable chairs or desks (OR: 3.35; 95% CI: 1.23-9.15), and working with a biosafety cabinet (OR: 2.49; 95% CI: 1.11-5.59). CTS cases had significant longer work duration (17.9 ± 5.6 years) than CTS non-case (11.5 ± 7.4 yeas) with low OR (1.108). Conclusion: This study demonstrates some personal and ergonomic factors associated with CTS among the laboratory technicians, including female gender, arm/hand exertion, pipetting, repetitive tasks, working with a biosafety cabinet, and an unadjusted workstation. PMID:28855446

  12. Fatigue induced changes in conical implant-abutment connections.

    PubMed

    Blum, Kai; Wiest, Wolfram; Fella, Christian; Balles, Andreas; Dittmann, Jonas; Rack, Alexander; Maier, Dominik; Thomann, Ralf; Spies, Benedikt Christopher; Kohal, Ralf Joachim; Zabler, Simon; Nelson, Katja

    2015-11-01

    Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Implant abutment deformation during prosthetic cylinder screw tightening: an in vitro study.

    PubMed

    Neto, Rafael Tobias Moretti; Moura, Marcio Silva; Souza, Edson Antonio Capello; Rubo, José Henrique

    2009-01-01

    Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Strain gauges were bonded to the sides of five standard abutments that had machined palladium-silver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 microepsilon. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 microepsilon (mean: 173.298 microepsilon) and from -5.62638 to -383.86 microepsilon (mean: 200.474 microepsilon) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time.

  14. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.

    PubMed

    do Nascimento, Cássio; Pedrazzi, Vinícius; Miani, Paola Kirsten; Moreira, Larissa Daher; de Albuquerque, Rubens Ferreira

    2009-12-01

    Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P<0.05). These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly.

  15. Organizational and psychosocial risk factors for carpal tunnel syndrome: a cross-sectional study of French workers.

    PubMed

    Rigouin, Pascal; Ha, Catherine; Bodin, Julie; Le Manac'h, Audrey Petit; Descatha, Alexis; Goldberg, Marcel; Roquelaure, Yves

    2014-02-01

    The aim of the study was to examine the organizational and psychosocial risk factors for carpal tunnel syndrome (CTS) in workers exposed to various levels of work-related constraints, with a special focus on factors related to the work organization. From 3,710 workers, representative of a French region's working population, trained occupational physicians diagnosed a total of 156 cases of CTS between 2002 and 2005. Diagnoses were established by standardized physical examination, while personal factors and work exposure were assessed by self-administered questionnaires. Statistical associations between CTS and personal and work-related factors were analyzed for each gender using logistic regression modeling. Among the factors related to work organization, working with temporary workers was associated with CTS for women (OR = 1.99, 95 % CI 1.23-3.25), but not for men. Task rotation during the job (OR = 2.45 95 % CI 1.41-4.24) and work pace dependent on quantified targets (OR = 1.93 95 % CI 1.08-3.46) were associated with CTS only for men. The work-related psychosocial factors highlighted by the logistic modeling were high psychological demand for women (OR = 1.90, 95 % CI 1.17-3.09) and low skill discretion (OR = 1.77, 95 % CI 1.01-3.11) for men. This study has identified some psychosocial factors and factors related to work organization associated with clinically diagnosed and symptom-only cases of CTS as well as personal and biomechanical factors. However, due to the cross-sectional design of the study, no causal conclusion could be drawn and longitudinal studies are necessary to confirm these results.

  16. Use of a decision aid did not decrease decisional conflict in patients with carpal tunnel syndrome.

    PubMed

    Gong, Hyun Sik; Park, Jin Woo; Shin, Young Ho; Kim, Kahyun; Cho, Kwan Jae; Baek, Goo Hyun

    2017-03-21

    Although a model for shared decision-making is important for patient-centered care, decisional conflict can emerge when patients participate in the decision-making. A decision aid is proposed to provide information and to involve patients more comfortably in the decision-making process. We aimed to determine whether a decision aid helps patients with carpal tunnel syndrome (CTS) experience less decisional conflict regarding their decision-making for surgery. Eighty patients with CTS were randomized into two groups. The test group was given a decision aid in addition to regular information and the control group regular information only. The decision aid consisted of a 6-min videoclip that explains diagnosis and information regarding surgery for CTS with other treatment options. We evaluated patients' decisional conflict regarding surgery, knowledge about CTS, and symptom severity as measured by the Disabilities of Arm, Shoulder, and Hand (DASH) Questionnaire. There was no difference in the decisional conflict scale (DCS) between both groups (p = 0.76). The test group had significantly better knowledge than the control group (p = 0.04). There was no correlation between the knowledge score and the DCS (p = 0.76). However, less severe symptoms were correlated with greater decisional conflict (r = -0.29, p = 0.02). We found that a decision aid does not reduce decisional conflict in patients with CTS, although it can help them be better informed. This study suggests that although a decision-aid is effective for patient education, doctor-patient communication should be more emphasized for patients with less severe symptoms, as they can have greater decisional conflict. SNUBH Registry 1510/317-003 Registered November 13, 2015.

  17. Comparison of the impact of scaler material composition on polished titanium implant abutment surfaces.

    PubMed

    Hasturk, Hatice; Nguyen, Daniel Huy; Sherzai, Homa; Song, Xiaoping; Soukos, Nikos; Bidlack, Felicitas B; Van Dyke, Thomas E

    2013-08-01

    The purpose of this study was to compare the impact of the removal of biofilm with hand scalers of different material composition on the surface of implant abutments by assessing the surface topography and residual plaque after scaling using scanning electron microscopy (SEM). Titanium implant analogs from 3 manufacturers (Straumann USA LLC, Andover, Maine, Nobel BioCare USA LLC, Yorba Linda, Cali, Astra Tech Implant Systems, Dentsply, Mölndal, Sweden) were mounted in stone in plastic vials individually with authentic prosthetic abutments. Plaque samples were collected from a healthy volunteer, inoculated into growth medium and incubated with the abutments anaerobically for 1 week. A blinded, calibrated hygienist performed scaling to remove the biofilm using 6 implant scalers (in triplicate), 1 scaler for 1 abutment. The abutments were mounted on an imaging stand and processed for SEM. Images were captured in 3 randomly designated areas of interest on each abutment. Analysis of the implant polished abutment surface and plaque area measurements were performed using ImageJ image analysis software. Surface alterations were characterized by the number, length, depth and the width of the scratches observed. Glass filled resin scalers resulted in significantly more and longer scratches on all 3 abutment types compared to other scalers, while unfilled resin scalers resulted in the least surface change (p < 0.05). Filled resin-graphite reinforced scalers, carbon fiber reinforced resin scalers and titanium scalers resulted in more superficial scratches compared to glass filled resin, as well as more scratches than unfilled resin. No statistically significant differences were found between scalers and abutments with regard to plaque removal. The impact of scalers on implant abutment surfaces varies between abutment types presumably due to different surface characteristics with no apparent advantage of one abutment type over the other with regard to resistance to surface

  18. An ergonomics study on the evaluation of carpal tunnel syndrome among Chikan embroidery workers of West Bengal, India.

    PubMed

    Gangopadhyay, Somnath; Chakrabarty, Sabarni; Sarkar, Krishnendu; Dev, Samrat; Das, Tamal; Banerjee, Sunetra

    2015-01-01

    Chikan embroidery is a popular handicraft in India that involves hand-intensive stitching while seated in a static posture with the upper back curved and the head bent over the fabric. Women perform most Chikan embroidery. The aim of this study was to analyze the repetitive nature of this work among female Chikan embroiderers by measuring the prevalence of upper extremity discomfort and carpal tunnel syndrome (CTS). The Nordic musculoskeletal questionnaire was used to analyze the extent of upper extremity pain symptomology. The repetitive nature of Chikan embroidery work was evaluated using the Assessment of Repetitive Tasks of the upper limbs tool (ART). Motor nerve conduction studies of median and ulnar nerves were performed with embroidery workers and a control group to determine the risk of CTS. Among embroidery workers, the prevalence of wrist pain was 68% and forearm pain was 60%. The embroiderers also commonly reported Tingling and numbness in the hands and fingertips. The ART analysis found that Chikan embroidery is a highly repetitive task and nerve conduction studies showed that the embroidery workers were more likely to experience CTS than women in the control group. Chikan embroidery is a hand-intensive occupation involving repetitive use of hands and wrists and this study population is at risk of experiencing CTS. Future research should explore the potential benefits of ergonomics measures including incorporating breaks, stretching exercises, and the use of wrist splints to reduce repetitive strain and the probability of developing CTS.

  19. Evaluation of Maryland abutment scour equation through selected threshold velocity methods

    USGS Publications Warehouse

    Benedict, S.T.

    2010-01-01

    The U.S. Geological Survey, in cooperation with the Maryland State Highway Administration, used field measurements of scour to evaluate the sensitivity of the Maryland abutment scour equation to the critical (or threshold) velocity variable. Four selected methods for estimating threshold velocity were applied to the Maryland abutment scour equation, and the predicted scour to the field measurements were compared. Results indicated that performance of the Maryland abutment scour equation was sensitive to the threshold velocity with some threshold velocity methods producing better estimates of predicted scour than did others. In addition, results indicated that regional stream characteristics can affect the performance of the Maryland abutment scour equation with moderate-gradient streams performing differently from low-gradient streams. On the basis of the findings of the investigation, guidance for selecting threshold velocity methods for application to the Maryland abutment scour equation are provided, and limitations are noted.

  20. Three-Dimensional Displacement of Nine Different Abutments for an Implant with an Internal Hexagon Platform.

    PubMed

    Gilbert, Andy B; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L; Chien, Hua-Hong

    2015-01-01

    Clinicians need to know whether there are any differences among the many abutment options available for restoring a particular implant. This study aims to compare nine abutments for one implant system for positional changes between hand tightening and torqueing. Nine Tapered Screw-Vent (TSV) implants were placed into a resin block. Five specimens of nine different abutments (n = 45) were tried in one of the nine implants. Initially, the abutments were torqued to 20 Ncm to represent hand tightening. Abutments were tightened to 30 Ncm using a torque driver as recommended by the manufacturer for final seating. Images were recorded in 12-second intervals for approximately 10 minutes after the torque was applied. The spatial relationship of the abutments to the resin block was determined using three-dimensional digital image correlation. Commercial image correlation software was used to analyze the displacements. Mean displacements for the nine different abutments were calculated in all three dimensions and for overall displacement in space. A t test with a step-down Bonferroni correction was used for a pairwise comparison of each abutment's mean displacements to the other abutments to determine statistical differences (α = .05). The Atlantis titanium, Inclusive titanium, and Legacy zirconia abutments showed mean displacements that were statistically significantly higher than other abutments in the horizontal direction. The overall three-dimensional displacement of the Atlantis titanium abutment after an applied 30-Ncm torque was significantly higher than that of six of the other eight abutments (P < .0144). Within the limitations of this in vitro study, the Zimmer PSA demonstrated less displacement between hand tightening and torqueing than the Atlantis titanium or Inclusive titanium abutments when used to restore a TSV implant.

  1. "…you earn money by suffering pain:" Beliefs About Carpal Tunnel Syndrome Among Latino Poultry Processing Workers.

    PubMed

    Arcury, Thomas A; Mora, Dana C; Quandt, Sara A

    2015-06-01

    The nature of poultry processing puts workers at risk for developing neurological injuries, particularly carpal tunnel syndrome (CTS). Many poultry processing workers are Latino immigrants. This qualitative analysis uses an explanatory models of illness (EMs) framework to describe immigrant Latino poultry processing workers' (Guatemalan and Mexican) beliefs of CTS. Understanding these workers' CTS EMs provides a foundation for recommendations to reduce the risk factors for this occupational injury. In-depth interviews were completed with 15 poultry processing workers diagnosed with CTS. Systematic qualitative analysis was used to delineate beliefs about causes, symptoms, physiology, treatments, quality-of-life and health implications of CTS. Participants' EMs largely reflect current biomedical understanding of CTS. These EMs are similar for Guatemalan and Mexican workers. Beliefs about causes include factors in the work environment (e.g., repetition, cold) and individual physical weakness. Treatments include over-the-counter medicine, as well as traditional remedies. Most know the future impact of CTS will include chronic pain. These workers know what causes CTS and that curing it would require quitting their jobs, but feel that they must endure CTS to support their families. Latino poultry processing workers, whether Guatemalan or Mexican, have a fairly complete understanding of what causes CTS, how to treat it, and what they must do to cure it. However, situational factors force them to endure CTS. Policy changes are needed to change the structure of work in poultry processing, particularly line speed and break frequency, if the prevalence of CTS is to be reduced.

  2. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    PubMed Central

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group) was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group) the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20). The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20). Data were analyzed with two- way ANOVA (α=0.05). Results: There was no significant difference in the mean transformed retention (Ln-R) between intact abutments (4.90±0.37) and the abutments with 3 walls (4.83±0.25) using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R) was significantly lower in the intact abutment (3.9±0.23) compared to the abutment with 3 walls (4.13±0.33, P=0.027). Conclusion: The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal. PMID:25628660

  3. The fracture strength by a torsion test at the implant-abutment interface.

    PubMed

    Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko

    2015-12-01

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p < 0.01). Concerning mean torsional yield strength, significant differences were found between 3.3, 3.8, and 4.3 mm-diameter and 5.0 and 6.0 mm-diameter implants (p < 0.01). Observations under the SEM showed that all the projections of the abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

  4. Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection.

    PubMed

    Cho, Sung-Yong; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2016-01-01

    This study investigated stress distribution in four different implant-abutment interface conditions in the internal tapered connection implant system. Four different implant diameters (3.5 mm, 4.0 mm, 4.5 mm, and 5.0 mm) and two abutment types (hexagonal and conical) were simulated. Four unique implant-abutment interface conditions were assumed based on wall thickness, mating surface length, distance to the vertical stop, and abutment shape. Axial and oblique loading was applied during abutment screw preload, and the Von Mises stresses were measured at the implant-abutment and abutment-screw interfaces. The implant-abutment interface stress decreased as the wall thickness increased. As the mating surface increased, the stress distribution trended downward, and when the distance to the implant vertical stop was 0 μm, the Von Mises stress was extremely high at the vertical stop. Despite their different shapes, the abutments showed similar stress distributions. However, the maximum Von Mises stress was higher in the conical connection than in the hexagonal connection, particularly at the contralateral side to loading. To decrease the stress distribution at the implant-abutment interface, the implant wall thickness, mating surface contact length, distance to the vertical stop, and abutment shape should be carefully considered.

  5. 19. DETAIL, WEST ABUTMENT, FROM NORTH, SHOWING SQUARED STONE MASONRY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. DETAIL, WEST ABUTMENT, FROM NORTH, SHOWING SQUARED STONE MASONRY ABUTMENT, WITH PORTION OF SUPERSTRUCTURE - Virginia Department of Transportation Bridge No. 6051, Spanning Catoctin Creek at State Route 673 (Featherbottom Road), Waterford, Loudoun County, VA

  6. The bacterial sealing capacity of morse taper implant-abutment systems in vitro.

    PubMed

    Ranieri, Rogerio; Ferreira, Andreia; Souza, Emmanuel; Arcoverde, Joao; Dametto, Fabio; Gade-Neto, Cicero; Seabra, Flavio; Sarmento, Carlos

    2015-05-01

    The use of Morse taper systems in dental implantology has been associated widely with a more precise adaptation between implants and their respective abutments. This may lead to an increase in the stability of the implant system and may also prevent microbial invasion through the implant-abutment interface. The aim of this study was to investigate in vitro the ability of four commercially available Morse taper system units to impede bacterial penetration through their implant-abutment interfaces. Abutments were screwed onto the implants, and the units were subsequently immersed in Streptococcus sanguinis bacterial broth (1 × 10(8) colony forming units/mL) for 48 hours. The units were examined by scanning electron microscopy (SEM) under three conditions: 1) with the implant-abutment components assembled as units to investigate for both the existence of microgaps and the presence of bacteria; 2) with the implants and abutments separated for examination of internal surfaces; and 3) with the implant-abutment components again assembled as units to measure any microgaps detected. The mean size of the microgaps in each unit was determined by measuring, under SEM, their width in four equidistant points. Microgaps were detected in all units with no significant differences in dimension (Kruskal-Wallis test, P >0.05). Within all units, the presence of bacteria was also observed. The seals provided by the interfaces of the commercially available Morse taper implant-abutment units tested were not sufficiently small to shield the implant from bacterial penetration.

  7. Load to failure of different zirconia implant abutments with titanium components.

    PubMed

    Mascarenhas, Faye; Yilmaz, Burak; McGlumphy, Edwin; Clelland, Nancy; Seidt, Jeremy

    2017-06-01

    Abutments with a zirconia superstructure and a titanium insert have recently become popular. Although they have been tested under static load, their performance under simulated mastication is not well known. The purpose of this in vitro study was to compare the cyclic load to failure of 3 types of zirconia abutments with different mechanisms of retention of the zirconia to the titanium interface. Fifteen implants (n=5 per system) and abutments (3 groups: 5 friction fit [Frft]; 5 bonded; and 5 titanium ring friction fit [Ringfrft]) were used. Abutments were thermocycled in water between 5°C and 55°C for 15000 cycles and then cyclically loaded for 20000 cycles or until failure at a frequency of 2 Hz by using a sequentially increased loading protocol up to a maximum of 720 N. The load to failure for each group was recorded, and 1-way analysis of variance was performed. The mean load-to-failure values for the Frft group was 526 N, for the Bond group 605 N, and for the Ringfrft group 288 N. A statistically significant difference was found among all abutments tested (P<.05). Abutments with the bonded connection showed the highest load-to-failure value, and the abutment with the titanium ring friction fit connection showed the lowest load-to-failure value. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. The influence of implant-abutment connection on the screw loosening and microleakage.

    PubMed

    Tsuruta, Katsuhiro; Ayukawa, Yasunori; Matsuzaki, Tatsuya; Kihara, Masafumi; Koyano, Kiyoshi

    2018-04-09

    There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant-abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant-abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. Within the

  9. 18. DETAIL, WEST ABUTMENT, FROM NORTHEAST, SHOWING SQUARED STONE MASONRY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAIL, WEST ABUTMENT, FROM NORTHEAST, SHOWING SQUARED STONE MASONRY ABUTMENT, WITH STRINGERS AND LATERAL BRACING - Virginia Department of Transportation Bridge No. 6051, Spanning Catoctin Creek at State Route 673 (Featherbottom Road), Waterford, Loudoun County, VA

  10. The upper bound of abutment scour defined by selected laboratory and field data

    USGS Publications Warehouse

    Benedict, Stephen; Caldwell, Andral W.

    2015-01-01

    The U.S. Geological Survey, in cooperation with the South Carolina Department of Transportation, conducted a field investigation of abutment scour in South Carolina and used that data to develop envelope curves defining the upper bound of abutment scour. To expand upon this previous work, an additional cooperative investigation was initiated to combine the South Carolina data with abutment-scour data from other sources and evaluate the upper bound of abutment scour with the larger data set. To facilitate this analysis, a literature review was made to identify potential sources of published abutment-scour data, and selected data, consisting of 446 laboratory and 331 field measurements, were compiled for the analysis. These data encompassed a wide range of laboratory and field conditions and represent field data from 6 states within the United States. The data set was used to evaluate the South Carolina abutment-scour envelope curves. Additionally, the data were used to evaluate a dimensionless abutment-scour envelope curve developed by Melville (1992), highlighting the distinct difference in the upper bound for laboratory and field data. The envelope curves evaluated in this investigation provide simple but useful tools for assessing the potential maximum abutment-scour depth in the field setting.

  11. Impact of abutment material on peri-implant soft tissue color. An in vitro study.

    PubMed

    Sala, Leticia; Bascones-Martínez, Antonio; Carrillo-de-Albornoz, Ana

    2017-09-01

    The objectives of the present study is to determine the differences in peri-implant soft tissue color with the utilization of titanium, titanium gold-plated, white zirconia, Vita Classical (VC) A4-shaded zirconia, and fluorescent white zirconia abutments and to establish the influence of gingival thickness on the resulting color. Four implants were contralaterally inserted in 19 fresh pig mandibles, and the color of the peri-implant mucosa with the different abutments was spectrophotometrically measured at 1-, 2-, and 3-mm height from the margin. At 1-mm height, titanium significantly differed from all zirconia abutments in lightness (L*), chroma along red axis (a*), and chroma along yellow-blue axis (b*) parameters. At 2 mm, all zirconia abutments differed from titanium in b* but only fluorescent zirconia in a*. At 3 mm, titanium differed from VC A4-shaded and fluorescent zirconia abutments in b*. At soft tissue thicknesses <1 and 1-2 mm, titanium differed from fluorescent zirconia in a* and b* and from VC A4-shaded zirconia in b*; at thickness >2 mm, no differences were found among abutments. All abutments differed from natural teeth in a* and b* at all heights and thicknesses except for fluorescent zirconia at thickness >2 mm. The Euclidean distance (ΔΕ) differed between titanium abutments and gold, VC A4, and fluorescent zirconia at <1- and 1-2-mm thicknesses. The natural gingival color was not reproduced with any abutment at gingival thicknesses <2 mm. The worst color match was with titanium abutments and the best with fluorescent zirconia, followed by VC A4-shaded zirconia. At gingival thicknesses >2 mm, no differences were detected among abutments. This study demonstrates that the type of abutment and the gingival thickness affect the resulting peri-implant gingival color.

  12. Effects of artificial aging conditions on yttria-stabilized zirconia implant abutments.

    PubMed

    Basílio, Mariana de Almeida; Cardoso, Kátia Vieira; Antonio, Selma Gutierrez; Rizkalla, Amin Sami; Santos Junior, Gildo Coelho; Arioli Filho, João Neudenir

    2016-08-01

    Most ceramic abutments are fabricated from yttria-stabilized tetragonal zirconia (Y-TZP). However, Y-TZP undergoes hydrothermal degradation, a process that is not well understood. The purpose of this in vitro study was to assess the effects of artificial aging conditions on the fracture load, phase stability, and surface microstructure of a Y-TZP abutment. Thirty-two prefabricated Y-TZP abutments were screwed and tightened down to external hexagon implants and divided into 4 groups (n = 8): C, control; MC, mechanical cycling (1×10(6) cycles; 10 Hz); AUT, autoclaving (134°C; 5 hours; 0.2 MPa); and TC, thermal cycling (10(4) cycles; 5°/55°C). A single-load-to-fracture test was performed at a crosshead speed of 0.5 mm/min to assess the assembly's resistance to fracture (ISO Norm 14801). X-ray diffraction (XRD) analysis was applied to observe and quantify the tetragonal-monoclinic (t-m) phase transformation. Representative abutments were examined with high-resolution scanning electron microscopy (SEM) to observe the surface characteristics of the abutments. Load-to-fracture test results (N) were compared by ANOVA and Tukey test (α=.05). XRD measurements revealed the monoclinic phase in some abutments after each aging condition. All the aging conditions reduced the fracture load significantly (P<.001). Mechanical cycling reduced the fracture load more than autoclaving (P=.034). No differences were found in the process of surface degradation among the groups; however, the SEM detected grinding-induced surface flaws and microcracks. The resistance to fracture and the phase stability of Y-TZP implant abutments were susceptible to hydrothermal and mechanical conditions. The surface microstructure of Y-TZP abutments did not change after aging conditions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Comparative Evaluation of Fracture Resistance and Mode of Failure of Zirconia and Titanium Abutments with Different Diameters.

    PubMed

    Shabanpour, Reza; Mousavi, Niloufar; Ghodsi, Safoura; Alikhasi, Marzieh

    2015-08-01

    The purpose of the current study was to compare the fracture resistance and mode of failure of zirconia and titanium abutments with different diameters. Fourteen groups of abutments including prefabricated zirconia, copy-milled zirconia and titanium abutments of an implant system (XiVE, Dentsply) were prepared in different diameters. An increasing vertical load was applied to each specimen until failure occurred. Fracture resistance was measured in each group using the universal testing machine. Moreover, the failure modes were studied and categorized as abutment screw fracture, connection area fracture, abutment body fracture, abutment body distortion, screw distortion and connection area distortion. Groups were statistically compared using univariate and post-hoc tests. The level of statistical significance was set at 5%. Fabrication method (p = 0.03) and diameter (p < 0.001) had significant effect on the fracture resistance of abutments. Fracture resistance of abutments with 5.5 mm diameter was higher than other diameters (p < 0.001). The observed modes of failure were dependent on the abutment material as well. All of the prefabricated titanium abutments fractured within the abutment screw. Abutment screw distortion, connection area fracture, and abutment body fracture were the common failure type in other groups. Diameter had a significant effect on fracture resistance of implant abutments, as abutments with greater diameters were more resistant to static loads. Copy-milled abutments showed lower fracture resistance as compared to other experimental groups. Although zirconia abutments have received great popularity among clinicians and even patients selecting them for narrow implants should be with caution.

  14. Microleakage at the Different Implant Abutment Interface: A Systematic Review

    PubMed Central

    Chowdhary, Ramesh; Kumari, Shail

    2017-01-01

    Introduction Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. Aim To evaluate the sealing capability of different implant connections against microleakage. Materials and Methods In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. Results In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. Conclusion In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics. PMID:28764310

  15. Endoscopic carpal tunnel release: a prospective analysis of factors associated with unsatisfactory results.

    PubMed

    Straub, T A

    1999-04-01

    The first 100 consecutive cases of endoscopic carpal tunnel release (ECTR) performed by the author were studied prospectively during 6 to 24 months follow-up. Various preoperative and postoperative factors were subjected to statistical analysis to determine possible associations with unsatisfactory results. Overall, 92% of hands had a satisfactory result from ECTR, although not all were rendered symptom-free. There were no significant complications. Preoperative factors associated with an increased likelihood of unsatisfactory results included hands with preoperative weakness, widened two-point discrimination, myofascial pain syndrome or fibromyalgia, involvement in litigation, multiple compressive neuropathies, or the presence of abnormal psychological factors. A trend to less satisfactory results was present in Workers' Compensation cases and patients with normal motor latencies on nerve conduction studies. Multiple postoperative factors correlated with unsatisfactory results.

  16. Fracture resistance of different implant abutments supporting 
all-ceramic single crowns after aging.

    PubMed

    Stimmelmayr, Michael; Heiß, Philipp; Erdelt, Kurt; Schweiger, Josef; Beuer, Florian

    To test the mechanical properties of three different restorative materials for implant abutments supporting all-ceramic single crowns. Thirty implants with butt-joint connections were distributed into three test groups: Group A with 10 one-piece zirconia abutments, Group U with 10 titanium abutments, and Group T with 10 titanium-zirconia hybrid abutments. Monolithic zirconia single crowns were cemented and artificially aged. The crowns were loaded at a 30-degree angle in a universal testing machine until fracture or bending. Additionally, after removal of the restorations, the implant-abutment interface of the fixtures was inspected using a scanning electron microscope (SEM). In Group A, the abutments failed on average at 336.78 N, in Group U at 1000.12 N, and in Group T at 1296.55 N. The mean values between Groups T and U (P = 0.009), and between Group A and Groups T and U (P < 0.001) were significantly different. The abutments in Group A failed early due to fractures of the internal parts and parts close to the implant neck. In Groups T and U, failures occurred due to bending of the implant neck. This experimental study proves that hybrid and titanium abutments have similar mechanical properties. One-piece abutments made of zirconia showed significantly lower fracture resistance.

  17. Removal torque of zirconia abutment screws under dry and wet conditions.

    PubMed

    Nigro, Frederico; Sendyk, Claudio L; Francischone, Carlos Eduardo; Francischone, Carlos Eduardo

    2010-01-01

    The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (α=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.

  18. Effectiveness of Surgical and Postsurgical Interventions for Carpal Tunnel Syndrome-A Systematic Review.

    PubMed

    Huisstede, Bionka M; van den Brink, Janneke; Randsdorp, Manon S; Geelen, Sven J; Koes, Bart W

    2017-05-31

    To present an evidence-based overview of the effectiveness of surgical and postsurgical interventions for carpal tunnel syndrome (CTS). The Cochrane Library, PubMed, EMBASE, CINAHL, and PEDro were searched for relevant systematic reviews and randomized controlled trials (RCTs) up to April 8, 2016. Two reviewers independently applied the inclusion criteria to select potential studies. Two reviewers independently extracted the data and assessed the methodologic quality. A best-evidence synthesis was performed to summarize the results. Four systematic reviews and 33 RCTs were included. Surgery versus nonsurgical interventions, timing of surgery, and various surgical techniques and postoperative interventions were studied. Corticosteroid injection was more effective than surgery (strong evidence, short-term). Surgery was more effective than splinting or anti-inflammatory drugs plus hand therapy (moderate evidence, midterm and long-term). Manual therapy was more effective than surgical treatment (moderate evidence, short-term and midterm). Within surgery, corticosteroid irrigation of the median nerve before skin closure as additive to CTS release or the direct vision plus tunneling technique was more effective than standard open CTS release (moderate evidence, short-term). Furthermore, short was more effective than long bulky dressings, and a sensory retraining program was more effective than no program after surgery (moderate evidence, short-term). For all other interventions only conflicting, limited, or no evidence was found. Surgical treatment seems to be more effective than splinting or anti-inflammatory drugs plus hand therapy in the short-term, midterm, and/or long-term to treat CTS. However there is strong evidence that a local corticosteroid injection is more effective than surgery in the short-term, and moderate evidence that manual therapy is more effective than surgery in the short-term and midterm. There is no unequivocal evidence that suggests one

  19. Fracture resistance of inter-joined zirconia abutment of dental implant system with injection molding technique.

    PubMed

    Yang, Jianjun; Wang, Ke; Liu, Guangyuan; Wang, Dashan

    2013-11-01

    Zirconia powder in nanometers can be fabricated into inter-joined abutment of dental implant system with the injection shaping technique. This study was to detect the resistance of inter-joined zirconia abutment with different angle loading for clinical applications. The inter-joined abutments were shaped with the technique of injection of zirconia powder in nanometers. Sixty Osstem GSII 5 × 10 mm implants were used with 30 zirconia abutments and 30 Osstem GSII titanium abutments for fixation using 40 N torque force. The loading applications included 90°, 30°, and 0° formed by the long axis of abutments and pressure head of universal test machine. The fracture resistances of zirconia and titanium abutments were documented and analyzed. The inter-joined zirconia abutments were assembled to the Osstem GSII implants successfully. In the 90° loading mode, the fracture resistance of zirconia abutment group and titanium abutment group were 301.5 ± 15.4 N and 736.4 ± 120.1 N, respectively. And those in the 30° groups were 434.7 ± 36.1 N and 1073.1 ± 74 N, correspondingly. Significant difference in the two groups was found using t-test and Wilcoxon test. No damage on the abutments of the two groups but S-shaped bending on the implants was found when the 0° loading was 1300-2000 N. Through the assembly of Zirconia abutments and implants, all the components presented sufficient resistance acquired for the clinical application under loadings with different angle. © 2012 John Wiley & Sons A/S.

  20. Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.

    PubMed

    Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon; Lee, Keun-Woo

    2016-12-01

    The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10 6 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups ( P >.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

  1. A finite element analysis of novel vented dental abutment geometries for cement‐retained crown restorations

    PubMed Central

    Rodriguez, Lucas C.; Saba, Juliana N.; Meyer, Clark A.; Chung, Kwok‐Hung; Wadhwani, Chandur

    2016-01-01

    Abstract Recent literature indicates that the long‐term success of dental implants is, in part, attributed to how dental crowns are attached to their associated implants. The commonly utilized method for crown attachment – cementation, has been criticized because of recent links between residual cement and peri‐implant disease. Residual cement extrusion from crown‐abutment margins post‐crown seating is a growing concern. This study aimed at (1) identifying key abutment features, which would improve dental cement flow characteristics, and (2) understanding how these features would impact the mechanical stability of the abutment under functional loads. Computational fluid dynamic modeling was used to evaluate cement flow in novel abutment geometries. These models were then evaluated using 3D‐printed surrogate models. Finite element analysis also provided an understanding of how the mechanical stability of these abutments was altered after key features were incorporated into the geometry. The findings demonstrated that the key features involved in improved venting of the abutment during crown seating were (1) addition of vents, (2) diameter of the vents, (3) location of the vents, (4) addition of a plastic screw insert, and (5) thickness of the abutment wall. This study culminated in a novel design for a vented abutment consisting of 8 vents located radially around the abutment neck‐margin plus a plastic insert to guide the cement during seating and provide retrievability to the abutment system.Venting of the dental abutment has been shown to decrease the risk of undetected residual dental cement post‐cement‐retained crown seating. This article will utilize a finite element analysis approach toward optimizing dental abutment designs for improved dental cement venting. Features investigated include (1) addition of vents, (2) diameter of vents, (3) location of vents, (4) addition of plastic screw insert, and (5) thickness of abutment wall. PMID

  2. A finite element analysis of novel vented dental abutment geometries for cement-retained crown restorations.

    PubMed

    Rodriguez, Lucas C; Saba, Juliana N; Meyer, Clark A; Chung, Kwok-Hung; Wadhwani, Chandur; Rodrigues, Danieli C

    2016-11-01

    Recent literature indicates that the long-term success of dental implants is, in part, attributed to how dental crowns are attached to their associated implants. The commonly utilized method for crown attachment - cementation, has been criticized because of recent links between residual cement and peri-implant disease. Residual cement extrusion from crown-abutment margins post-crown seating is a growing concern. This study aimed at (1) identifying key abutment features, which would improve dental cement flow characteristics, and (2) understanding how these features would impact the mechanical stability of the abutment under functional loads. Computational fluid dynamic modeling was used to evaluate cement flow in novel abutment geometries. These models were then evaluated using 3D-printed surrogate models. Finite element analysis also provided an understanding of how the mechanical stability of these abutments was altered after key features were incorporated into the geometry. The findings demonstrated that the key features involved in improved venting of the abutment during crown seating were (1) addition of vents, (2) diameter of the vents, (3) location of the vents, (4) addition of a plastic screw insert, and (5) thickness of the abutment wall. This study culminated in a novel design for a vented abutment consisting of 8 vents located radially around the abutment neck-margin plus a plastic insert to guide the cement during seating and provide retrievability to the abutment system.Venting of the dental abutment has been shown to decrease the risk of undetected residual dental cement post-cement-retained crown seating. This article will utilize a finite element analysis approach toward optimizing dental abutment designs for improved dental cement venting. Features investigated include (1) addition of vents, (2) diameter of vents, (3) location of vents, (4) addition of plastic screw insert, and (5) thickness of abutment wall.

  3. Validity of the Upper Limb Neurodynamic Test 1 for the diagnosis of Carpal Tunnel Syndrome. The role of structural differentiation.

    PubMed

    Bueno-Gracia, Elena; Tricás-Moreno, José Miguel; Fanlo-Mazas, Pablo; Malo-Urriés, Miguel; Haddad-Garay, María; Estébanez-de-Miguel, Elena; Hidalgo-García, César; Krauss, John R

    2016-04-01

    Several studies have analysed the use of the Upper Limb Neurodynamic Test 1 (ULNT1) for diagnosing Carpal Tunnel Syndrome (CTS) obtaining weak diagnostic accuracy, which could be related to the lack of consensus in the selected diagnostic criteria of ULNT1. To determine the concurrent validity of ULNT1 in comparison to Nerve Conduction Studies (NCS) for the diagnosis of CTS, considering the structural differentiation (SD) as an essential part of the diagnosis. Prospective diagnostic test study. Individuals with suspected CTS referred for NCS were invited to voluntarily participate in the study. Each participant was tested with NCS and ULNT1. ULNT1 result was considered positive when the patient's clinical symptoms were reproduced during the test and symptoms changed during contralateral neck side bending (SD). 58 Participants (17 men, 44 women) with suspected CTS and a total of 95 limbs were examined using the NCS and ULNT1. Sensitivity of the ULNT1 was 57.9%, specificity was 84.2%, and the positive and negative likelihood ratios were 3.67 and 0.50 respectively. Results obtained in the study may indicate the ability of the ULNT1 to generate small shifts from pre-test to post-test probability. However, imprecision in the CIs limits interpretation from the data. 1b. Published by Elsevier Ltd.

  4. Influence of Abutment Color and Mucosal Thickness on Soft Tissue Color.

    PubMed

    Ferrari, Marco; Carrabba, Michele; Vichi, Alessandro; Goracci, Cecilia; Cagidiaco, Maria Crysanti

    Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. Ninety patients were included in the study. Each patient was provided with an implant (OsseoSpeed, Dentsply Implant System). A two-stage surgical technique was performed. Six months later, surgical reentry was performed. After 1 week, provisional restorations were screwed onto the implants. After 8 weeks, implant-level impressions were taken and soft tissue thickness was recorded, ranking thin (≤ 2 mm) or thick (≥ 2 mm). Patients were randomly allocated to three experimental groups, based on abutment type: (1) Ti, (2) TiN, and (3) ZrO₂. After 15 weeks, the final restorations were delivered. The mucosal area referring to each abutment was measured for color using a clinical spectrophotometer (Easyshade, VITA); color measurements of the contralateral areas referring to natural teeth were performed at the same time. The data were collected using the Commission Internationale de l'Eclairage (CIE) L*a*b* color system, and ΔE was calculated between peri-implant and contralateral soft tissues. A critical threshold of ΔE = 3.7 was selected. The chi-square test was used to identify statistically significant differences in ΔE between thin and thick mucosal tissues and among the abutment types. Three patients were lost at follow-up. No statistically significant differences were noticed as to the abutment type (P = .966). Statistically significant differences in ΔE were recorded between thick and thin peri-implant soft tissues (P < .001). Only 2 out of 64 patients with thick soft tissues showed a ΔE higher than 3.7: 1 in the TiN group and 1 in the ZrO₂ group. All the patients with thin soft tissues reported color

  5. Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution.

    PubMed

    Duarte, Antônio R C; Neto, João P Silva; Souza, Júlio C M; Bonachela, Wellington C

    2013-06-01

    Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conexão®, (E) Emfils®, (I) INP®, (S) SIN®, and (T) Titanium Fix®. The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20 Ncm using a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronic microscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions. © 2012 by the American College of Prosthodontists.

  6. Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

    PubMed Central

    Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon

    2016-01-01

    PURPOSE The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 106 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment. PMID:28018564

  7. Evaluation of median nerve T2 signal changes in patients with surgically treated carpal tunnel syndrome.

    PubMed

    Samanci, Yavuz; Karagöz, Yeşim; Yaman, Mehmet; Atçı, İbrahim Burak; Emre, Ufuk; Kılıçkesmez, Nuri Özgür; Çelik, Suat Erol

    2016-11-01

    To determine the accuracy of median nerve T2 evaluation and its relation with Boston Questionnaire (BQ) and nerve conduction studies (NCSs) in pre-operative and post-operative carpal tunnel syndrome (CTS) patients in comparison with healthy volunteers. Twenty-three CTS patients and 24 healthy volunteers underwent NCSs, median nerve T2 evaluation and self-administered BQ. Pre-operative and 1st year post-operative median nerve T2 values and cross-sectional areas (CSAs) were compared both within pre-operative and post-operative CTS groups, and with healthy volunteers. The relationship between MRI findings and BQ and NCSs was analyzed. The ROC curve analysis was used for determining the accuracy. The comparison of pre-operative and post-operative T2 values and CSAs revealed statistically significant improvements in the post-operative patient group (p<0.001 for all parameters). There were positive correlations between T2 values at all levels and BQ values, and positive and negative correlations were also found regarding T2 values and NCS findings in CTS patients. The receiver operating characteristic curve analysis for defined cut-off levels of median nerve T2 values in hands with severe CTS yielded excellent accuracy at all levels. However, this accuracy could not be demonstrated in hands with mild CTS. This study is the first to analyze T2 values in both pre-operative and post-operative CTS patients. The presence of increased T2 values in CTS patients compared to controls and excellent accuracy in hands with severe CTS indicates T2 signal changes related to CTS pathophysiology and possible utilization of T2 signal evaluation in hands with severe CTS. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Comparison of Risk of Carpal Tunnel Syndrome in Patients with Distal Radius Fractures After 7 Treatments

    PubMed Central

    Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617

  9. Holt-oram syndrome associated with double outlet right ventricle: A rare association

    PubMed Central

    Singh, Bhupinder; Kariyappa, Mallesh; Vijayalakshmi, Ishwarappa Balekundri; Nanjappa, Manjunath C

    2013-01-01

    Holt-Oram syndrome is a rare inherited disorder that causes abnormalities of the hands, arms, and the heart. Most commonly, there are defects in the carpal bones of the wrist and in the bones of the thumb along with cardiac defects such as atrial or ventricular septal defects. We report a case of Holt-Oram syndrome with a rare association of double outlet right ventricle. PMID:23626447

  10. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    PubMed

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  11. An ergonomics study on the evaluation of carpal tunnel syndrome among Chikan embroidery workers of West Bengal, India

    PubMed Central

    Gangopadhyay, Somnath; Chakrabarty, Sabarni; Sarkar, Krishnendu; Dev, Samrat; Das, Tamal; Banerjee, Sunetra

    2015-01-01

    Background: Chikan embroidery is a popular handicraft in India that involves hand-intensive stitching while seated in a static posture with the upper back curved and the head bent over the fabric. Women perform most Chikan embroidery. Objectives: The aim of this study was to analyze the repetitive nature of this work among female Chikan embroiderers by measuring the prevalence of upper extremity discomfort and carpal tunnel syndrome (CTS). Methods: The Nordic musculoskeletal questionnaire was used to analyze the extent of upper extremity pain symptomology. The repetitive nature of Chikan embroidery work was evaluated using the Assessment of Repetitive Tasks of the upper limbs tool (ART). Motor nerve conduction studies of median and ulnar nerves were performed with embroidery workers and a control group to determine the risk of CTS. Results: Among embroidery workers, the prevalence of wrist pain was 68% and forearm pain was 60%. The embroiderers also commonly reported Tingling and numbness in the hands and fingertips. The ART analysis found that Chikan embroidery is a highly repetitive task and nerve conduction studies showed that the embroidery workers were more likely to experience CTS than women in the control group. Conclusions: Chikan embroidery is a hand-intensive occupation involving repetitive use of hands and wrists and this study population is at risk of experiencing CTS. Future research should explore the potential benefits of ergonomics measures including incorporating breaks, stretching exercises, and the use of wrist splints to reduce repetitive strain and the probability of developing CTS. PMID:25658674

  12. GRS bridge piers and abutments.

    DOT National Transportation Integrated Search

    2001-01-01

    This report presents the following three recent projects on load testing of geosynthetic-reinforced soil (GRS) bridge abutments and piers: a full-scale bridge pier load test conducted by the Turner-Fairbank Highway Research Center, Federal Highway Ad...

  13. Five-year multicenter study of magnetic attachments used for natural overdenture abutments.

    PubMed

    Gonda, T; Yang, T C; Maeda, Y

    2013-04-01

    The purpose of this study was to examine a longitudinal clinical performance of magnetic attachments used for natural overdenture abutments. The study included 131 patients who had used removable prostheses (complete overdentures 31%, partial dentures 69%) more than 5 years (40-90 years old) with 211 magnetic attachments on natural abutments (Magfit 400 or 600; Aichi Steel co., Aichi, Japan) treated in 15 clinics using a standardized protocol. Analyses were performed on the degree of patient satisfaction regarding retention, complications of magnets (corrosion, detachment from denture base), abutments (pain during mastication, periodontal pocket formation, inflammation, mobility), and dentures (fracture etc.). Ninety-seven percent of patients were satisfied with the retention and stability of their dentures. No corrosion of magnet was observed, and 19 magnets were detached. Most frequent complication of abutments was periodontal pocket formation (52%), followed by the inflammation (29%), increase in mobility (27%) and pain (4%). Magnetic attachment on natural tooth abutments provided a viable and long-term treatment option. © 2013 Blackwell Publishing Ltd.

  14. Can the Hydroxyapatite-Coated Skin-Penetrating Abutment for Bone Conduction Hearing Implants Integrate with the Surrounding Skin?

    PubMed

    van Hoof, Marc; Wigren, Stina; Duimel, Hans; Savelkoul, Paul H M; Flynn, Mark; Stokroos, Robert Jan

    2015-01-01

    Percutaneous implants, such as bone conduction hearing implants, suffer from complications that include inflammation of the surrounding skin. A sealed skin-abutment interface can prevent the ingress of bacteria, which should reduce the occurrence of peri-abutment dermatitis. It was hypothesized that a hydroxyapatite (HA)-coated abutment in conjunction with soft tissue preservation surgery should enable integration with the adjacent skin. Previous research has confirmed that integration is never achieved with as-machined titanium abutments. Here, we investigate, in vivo, if skin integration is achievable in patients using a HA-coated abutment. One titanium abutment (control) and one HA-coated abutment (case) together with the surrounding skin were surgically retrieved from two patients who had a medical indication for this procedure. Histological sections of the skin were investigated using light microscopy. The abutment was qualitatively analyzed using scanning electron microscopy. The titanium abutment only had a partial and thin layer of attached amorphous biological material. The HA-coated abutment was almost fully covered by a pronounced thick layer of organized skin, composed of different interconnected structural layers. Proof-of-principle evidence that the HA-coated abutment can achieve integration with the surrounding skin was presented for the first time.

  15. Short-term clinical outcome of orthosis alone vs combination of orthosis, nerve, and tendon gliding exercises and ultrasound therapy for treatment of carpal tunnel syndrome.

    PubMed

    Sim, Sze En; Gunasagaran, Jayaletchumi; Goh, Khean-Jin; Ahmad, Tunku Sara

    2018-02-07

    Prospective randomized study. Carpal tunnel syndrome (CTS) has been described as the most common compression neuropathy. Many modalities exist for conservative treatment. Efficacy of each modality has been described in the literature. However, the effectiveness of combination of these modalities is not well established. The purpose of this study is to assess the short-term clinical outcome of conservative treatment for CTS comparing orthosis alone with combination of orthosis, nerve/tendon gliding exercises, and ultrasound therapy. Forty-one patients who presented to Upper Limb Reconstructive and Microsurgery Clinic, University Malaya Medical Centre with CTS and positive electrodiagnostic study were recruited. Fifteen patients had bilateral CTS. Fifty-six wrists were equally randomized to orthosis alone and a combined therapy of orthosis, nerve/tendon gliding exercise, and ultrasound therapy. All patients were required to complete the Boston Carpal Tunnel Questionnaire during the first visit and 2 months after treatment. Both the orthosis and combined therapy groups showed a significant improvement in symptoms and function after treatment. The mean difference of symptoms in the orthosis group was 0.53; 95% confidence interval [CI]: 0.23-0.83 (P = .001) and in the combined therapy group was 0.48; 95% CI: 0.24-0.72 (P < .001). Mean difference of function in the orthosis group was 0.59; 95% CI: 0.28-0.91 (P = .001) and combined group was 0.69; 95% CI: 0.49-0.89 (P < .001). However, there was no significant difference in symptom severity and functional status scores between the groups. Our findings support other findings where orthosis and exercises improved symptom severity and functional status scores, however, there was no significant difference between orthosis alone and combined treatment. Patients who underwent conservative management for CTS showed improvement in symptoms and function. However, the combination of orthosis, nerve/tendon gliding exercises

  16. Biomechanical evaluation of different abutment-implant connections - A nonlinear finite element analysis

    NASA Astrophysics Data System (ADS)

    Ishak, Muhammad Ikman; Shafi, Aisyah Ahmad; Rosli, M. U.; Khor, C. Y.; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Jamalludin, Mohd Riduan

    2017-09-01

    The success of dental implant surgery is majorly dependent on the stability of prosthesis to anchor to implant body as well as the integration of implant body to bone. The attachment between dental implant body and abutment plays a vital role in attributing to the stability of dental implant system. A good connection between implant body cavity to abutment may minimize the complications of abutment loosening and implant fractures as widely reported in clinical findings. The aim of this paper is to investigate the effect of different abutment-implant connections on stress dispersion within the abutment and implant bodies as well as displacement of implant body via three-dimensional (3-D) finite element analysis (FEA). A 3-D model of mandible was reconstructed from computed tomography (CT) image datasets using an image-processing software with the selected region of interest was the left side covering the second premolar, first molar and second molar regions. The bone was modelled as compact (cortical) and porous (cancellous) structures. Besides, three implant bodies and three generic models of abutment with different types of connections - tapered interference fit (TIF), tapered integrated screwed-in (TIS) and screw retention (SR) were created using computer-aided design (CAD) software and all models were then analysed via 3D FEA software. Occlusal forces of 114.6 N, 17.2 N and 23.4 N were applied in the axial, lingual and mesio-distal directions, respectively, on the top surface of first molar crown. All planes of the mandibular bone model were rigidly fixed. The result exhibited that abutment with TIS connection produced the most favourable stress and displacement outcomes as compared to other attachment types. This is due to the existence of integrated screw at the bottom portion of tapered abutment which increases the motion resistance.

  17. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.

    PubMed

    Mühlemann, Sven; Truninger, Thomas C; Stawarczyk, Bogna; Hämmerle, Christoph H F; Sailer, Irena

    2014-01-01

    To test the fracture load and fracture patterns of zirconia abutments restored with all-ceramic crowns after fatigue loading, exhibiting internal and external implant-abutment connections as compared to restored and internally fixed titanium abutments. A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test). The groups differed according to their implant-abutment connections: one-piece internal connection (BL; Straumann Bonelevel), two-piece internal connection (RS; Nobel Biocare ReplaceSelect), external connection (B; Branemark MkIII), two-piece internal connection (SP, Straumann StandardPlus) and one-piece internal connection (A; Astra Tech AB OsseoSpeed). Titanium abutments with internal implant-abutment connection (T; Straumann Bonelevel) served as control group. In each group, 12 abutments were fabricated, mounted to the respective implants and restored with glass-ceramic crowns. All samples were embedded in acrylic holders (ISO-Norm 14801). After aging by means of thermocycling in a chewing simulator, static load was applied until failure (ISO-Norm 14801). Fracture load was analyzed by calculating the bending moments. Values of all groups were compared with one-way ANOVA followed by Scheffé post hoc test (P-value<0.05). Failure mode was analyzed descriptively. The mean bending moments were 464.9 ± 106.6 N cm (BL), 581.8 ± 172.8 N cm (RS), 556.7 ± 128.4 N cm (B), 605.4 ± 54.7 N cm (SP), 216.4 ± 90.0 N cm (A) and 1042.0 ± 86.8 N cm (T). No difference of mean bending moments was found between groups BL, RS, B and SP. Test group A exhibited significantly lower mean bending moment than the other test groups. Control group T had significantly higher bending moments than all test groups. Failure due to fracture of the abutment and/or crown occurred in the test groups. In groups BL and A, fractures were located in the internal part of the connection, whereas in groups RS and SP, a partial

  18. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    PubMed

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. The role of dental implant abutment design on the aesthetic outcome: preliminary 3-month post-loading results from a multicentre split-mouth randomised controlled trial comparing two different abutment designs.

    PubMed

    Esposito, Marco; Cardaropoli, Daniele; Gobbato, Luca; Scutellà, Fabio; Fabianelli, Andrea; Mascellani, Saverio; Delli Ficorelli, Gianluca; Mazzocco, Fabio; Sbricoli, Luca; Trullenque-Eriksson, Anna

    To evaluate whether there are aesthetic and clinical benefits to using a newly designed abutment (Curvomax), over a conventional control abutment (GingiHue). A total of 49 patients, who required at least two implants, had two sites randomised according to a split-mouth design to receive one abutment of each type at seven different centres. The time of loading (immediate, early or delayed) and of prosthesis (provisional crowns of fixed prosthesis) was decided by the clinicians, but they had to restore both implants in a similar way. Provisional prostheses were replaced by definitive ones 3 months after initial loading, when the follow-up for the initial part of this study was completed. Outcome measures were: prosthesis failures, implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, and patient preference. In total, 49 Curvomax and 49 GingiHue abutments were delivered. Two patients dropped out. No implant failure, prosthesis failure or complication was reported. There were no differences at 3 months post-loading for PES (difference = -0.15, 95% CI -0.55 to 0.25; P (paired t test) = 0.443) and marginal bone level changes (difference = -0.02 mm, 95% CI -0.20 to 0.16; P (paired t test) = 0.817). The majority of the patients (30) had no preference regarding the two abutment designs; 11 patients preferred the Curvomax, while five patients preferred the GingiHue abutments (P (McNemar test) = 0.210). The preliminary results of the comparison between two different abutment designs did not disclose any statistically significant differences between the evaluated abutments. However the large number of missing radiographs and clinical pictures casts doubt on the reliability of the results. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two abutment designs. Conflict of interest statement: This research project was originally partially funded by

  20. Experimental conical-head abutment screws on the microbial leakage through the implant-abutment interface: an in vitro analysis using target-specific DNA probes.

    PubMed

    Pita, Murillo S; do Nascimento, Cássio; Dos Santos, Carla G P; Pires, Isabela M; Pedrazzi, Vinícius

    2017-07-01

    The aim of this in vitro study was to identify and quantify up to 38 microbial species from human saliva penetrating through the implant-abutment interface in two different implant connections, external hexagon and tri-channel internal connection, both with conventional flat-head or experimental conical-head abutment screws. Forty-eight two-part implants with external hexagon (EH; n = 24) or tri-channel internal (TI; n = 24) connections were investigated. Abutments were attached to implants with conventional flat-head or experimental conical-head screws. After saliva incubation, Checkerboard DNA-DNA hybridization was used to identify and quantify up to 38 bacterial colonizing the internal parts of the implants. Kruskal-Wallis test followed by Bonferroni's post-tests for multiple comparisons was used for statistical analysis. Twenty-four of thirty-eight species, including putative periodontal pathogens, were found colonizing the inner surfaces of both EH and TI implants. Peptostreptococcus anaerobios (P = 0.003), Prevotella melaninogenica (P < 0.0001), and Candida dubliniensis (P < 0.0001) presented significant differences between different groups. Means of total microbial count (×10 4 , ±SD) for each group were recorded as follows: G1 (0.27 ± 2.04), G2 (0 ± 0), G3 (1.81 ± 7.50), and G4 (0.35 ± 1.81). Differences in the geometry of implant connections and abutment screws have impacted the microbial leakage through the implant-abutment interface. Implants attached with experimental conical-head abutment screws showed lower counts of microorganisms when compared with conventional flat-head screws. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    PubMed Central

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  2. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    PubMed

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p < .05). The highest fracture loads were associated with metal-ceramic crowns supported by titanium abutments (p = .000). IPS Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  3. Evaluation of Dynamic Characteristics of the Footbridge with Integral Abutments

    NASA Astrophysics Data System (ADS)

    Pańtak, Marek; Jarek, Bogusław

    2017-09-01

    The paper presents the results of dynamic field tests and numerical analysis of the footbridge designed as a three-span composite structure with integral abutments. The adopted design solution which has allowed to achieve a high resistance of the structure to dynamic loads and to meet the requirements of the criteria of comfort of use with a large reserve has been characterized. For comparative purposes, numerical analyzes of three construction variants of the footbridge were presented: F-1 - construction with integral abutments (realized variant), F-2 - construction with girders anchored in the abutments by means of tension rocker bearings, F-3 - construction with concrete side spans.

  4. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

    PubMed Central

    DE JESUS TAVAREZ, Rudys Rodolfo; BONACHELA, Wellington Cardoso; XIBLE, Anuar Antônio

    2011-01-01

    Objective The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. Material and Methods Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey’s post-hoc test (p<0.05). Results Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. Conclusion The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface. PMID:21437464

  5. Management of overdenture abutments health by an innovative cleaning aid

    PubMed Central

    Mall, Priyanka; Singh, Kamleshwar; Singh, Saumyendra Vikram; Agrawal, Kaushal Kishor; Siddharth, Ramashanker; Chand, Pooran

    2012-01-01

    This article describes a method for fabrication of a custom-made device for cleaning dome-shaped overdenture abutments. A kid toothbrush and a rubber cup were used for fabrication of a prophylactic device. After regular use of this device periodontal health status of the overdenture abutments patients improved satisfactorily. PMID:23230248

  6. The use of small (2.7 mm) screws for arthroscopically guided repair of carpal chip fractures.

    PubMed

    Wright, I M; Smith, M R W

    2011-05-01

    Removal of large chip fractures of the carpal bones and the osteochondral deficits that result, have been associated with a worse prognosis than removal of small fragments in similar locations. Reducing the articular defects by repair of large osteochondral fragments may have advantages over removal. Horses with osteochondral chip fractures that were of sufficient size and infrastructure to be repaired with small (2.7 mm diameter) AO/ASIF cortex screws were identified and repair effected by arthroscopically guided internal fixation. Thirty-three horses underwent surgery to repair 35 fractures of the dorsodistal radial carpal bone (n = 25), the dorsal margin of the radial facet of the third carpal bone (n = 9) and the intermediate facet of the distal radius (n = 1). There were no surgical complications and fractures healed satisfactorily in 26 of 28 horses and 23 horses returned to racing performance. Arthroscopically guided repair of carpal chip fractures with small diameter cortex screws is technically feasible and experiences with 33 cases suggest that this may have advantages over fragment removal in managing such cases. Surgeons treating horses with large chip fractures of the carpal bones should consider arthroscopically guided internal fixation as an alternative to removal. © 2010 EVJ Ltd.

  7. Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics.

    PubMed

    Kim, Aram; Campbell, Stephen D; Viana, Marlos A G; Knoernschild, Kent L

    2016-12-01

    The purpose of this study was to evaluate the effect of implant abutment material on peri-implant soft tissue color using intraoral spectrophotometric analysis and to compare the clinical outcomes with patient and clinician perception and satisfaction. Thirty patients and four prosthodontic faculty members participated. Abutments were zirconia, gold-hued titanium, and titanium. Peri-implant mucosa color of a single anterior implant restoration was compared to the patient's control tooth. Spectrophotometric analysis using SpectroShade TM Micro data determined the color difference (ΔE, ΔL*, Δa*, Δb*) between the midfacial peri-implant soft tissue for each abutment material and the marginal gingiva of the control tooth. Color difference values of the abutment groups were compared using ANOVA (α = 0.05). Patient and clinician satisfaction surveys were also conducted using a color-correcting light source. The results of each patient and clinician survey question were compared using chi-square analysis (α = 0.05). Pearson correlation analyses identified the relationship between the total color difference (ΔE) and the patient/clinician perception and satisfaction, as well as between ΔE and tissue thickness. Zirconia abutments displayed significantly smaller spectrophotometric gingival color difference (ΔE) compared to titanium and gold-hued titanium abutments (respectively, 3.98 ± 0.99; 7.22 ± 3.31; 5.65 ± 2.11; p < 0.05). Among ΔL*, Δa*, and Δb*, only Δa* (red-green spectrum) showed significant difference between groups. There was no significant correlation between measured soft tissue thickness and ΔE, but thick gingival phenotype, determined by a probe test, demonstrated a smaller ΔE than thin phenotype (4.82 ± 1.49; 6.41 ± 3.27; p = 0.097). There was no statistical difference in patient or clinician satisfaction among abutment materials, and no correlation between ΔE and the patient and clinician satisfaction. Patient satisfaction was

  8. Comparison of third-year medical and physical therapy students' knowledge of anatomy using the carpal bone test.

    PubMed

    Valenza, Marie Carmen; Castro-Martín, Eduardo; Valenza, Gerad; Guirao-Piñeiro, Miguel; De-la-Llave-Rincón, Ana Isabel; Fernández-de-las-Peñas, César

    2012-02-01

    The curricula of all health professionals have an important foundation of human anatomy. A comparison of the anatomy retention between students from different curricula has not been studied. Our aim was to examine the knowledge competency of third-year physical therapy and medical students in carpal bone anatomy. The testing was conducted on the third-year medical and physical therapy students at Universidad de Granada. Students were given 5 minutes to answer the carpal bone test, a test which requires the identification of the carpal bones in an illustration of the bony skeleton of carpal region. Differences in the distribution of the responses between groups were analyzed using the χ(2) test. One hundred thirty-four (n = 134) tests were analyzed (n = 54 [41%] physical therapy students, n = 80 [59%] medical students). Only 39 students correctly identified all of the carpal bones (42.6% physical therapy, 20% medical, P < .001). Physical therapy students correctly identified a greater number (P < .001) of carpal bones (mean ± SD, 5.8 ± 2.2) than medical students (mean ± SD, 3.1 ± 2.9). The capitate was the most frequently identified bone in both physical therapy (96%) and medical (46%) students (P < .001). The hamate bone was the least frequently identified bone by medical students (n = 29, or 36.3%), whereas the trapezoid bone was the least frequently identified bone by physical therapy students (n = 35, or 64.8%). There are few studies investigating anatomical knowledge levels between disciplines. This study found that physical therapy students exhibited better retention of anatomy of the carpal bones than medical students. Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  9. Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws.

    PubMed

    Zipprich, Holger; Rathe, Florian; Pinz, Sören; Schlotmann, Luca; Lauer, Hans-Christoph; Ratka, Christoph

    The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.

  10. 23. VIEW LOOKING UPSTREAM AND TOWARD LEFT ABUTMENT OF DAM. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. VIEW LOOKING UPSTREAM AND TOWARD LEFT ABUTMENT OF DAM. NOTE FORMS FOR LEFT GRAVITY ABUTMENT AT UPPER RIGHT CORNER OF PICTURE. ARCHES 3, 4, 5, AND 7 COMPLETED TO ELEVATION 1795. 5 OR 7.5 FEET BELOW TOP OF PARAPET WALL. November 29, 1938 - Bartlett Dam, Verde River, Phoenix, Maricopa County, AZ

  11. Displacement comparison of CAD-CAM titanium and zirconia abutments to implants with different conical connections.

    PubMed

    Yilmaz, Burak; Hashemzadeh, Shervin; Seidt, Jeremy D; Clelland, Nancy L

    2018-04-01

    To compare the displacements of CAD-CAM zirconia and titanium abutments into different internal connection systems after torquing. OsseoSpeed EV and OsseoSpeed TX implants (n=10) were placed in resin blocks. Zirconia and titanium abutments (n=5) were first hand tightened and then tightened to the recommended torque (20Ncm for TX and 25Ncm for EV). Displacements of abutments between screw tightening by hand and torque driver was measured using three-dimensional digital image correlation (3D DIC) technique. Displacements were measured in U (front/back), V (into/outward), W (right/left) directions and 3-dimensionally (3D). ANOVA with restricted maximum likelihood estimation method was used to analyze the data. Bonferroni-corrected t tests was used to determine the statistical differences (α=0.05). 3D displacement of zirconia and titanium abutments was significantly greater in OsseoSpeed EV implant (P<0.001). Displacement of zirconia and titanium abutments was not significantly different within implant systems, 3D (P≥0.386) and in each direction (P≥0.382). In U and V directions, zirconia and titanium abutments displaced significantly more towards negative in OsseoSpeed EV implant (P<0.019). Within the OsseoSpeed TX system, abutments displaced significantly more in V direction compared to the U and W (P≤0.005), and within the Osseospeed EV system, abutment displacements were significantly different amongst directions and displacements in V were the greatest (P<0.001). Abutments displaced more in the implant that required higher torque values to tighten the abutment. The amount of displacement in both systems was clinically small. Abutment material did not affect the magnitude of displacement. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Removal Torque and Biofilm Accumulation at Two Dental Implant-Abutment Joints After Fatigue.

    PubMed

    Pereira, Jorge; Morsch, Carolina S; Henriques, Bruno; Nascimento, Rubens M; Benfatti, Cesar Am; Silva, Filipe S; López-López, José; Souza, Júlio Cm

    2016-01-01

    The aim of this study was to evaluate the removal torque and in vitro biofilm penetration at Morse taper and hexagonal implant-abutment joints after fatigue tests. Sixty dental implants were divided into two groups: (1) Morse taper and (2) external hexagon implant-abutment systems. Fatigue tests on the implant-abutment assemblies were performed at a normal force (FN) of 50 N at 1.2 Hz for 500,000 cycles in growth medium containing human saliva for 72 hours. Removal torque mean values (n = 10) were measured after fatigue tests. Abutments were then immersed in 1% protease solution in order to detach the biofilms for optical density and colony-forming unit (CFU/cm²) analyses. Groups of implant-abutment assemblies (n = 8) were cross-sectioned at 90 degrees relative to the plane of the implant-abutment joints for the microgap measurement by field-emission guns scanning electron microscopy. Mean values of removal torque on abutments were significantly lower for both Morse taper (22.1 ± 0.5 μm) and external hexagon (21.1 ± 0.7 μm) abutments after fatigue tests than those recorded without fatigue tests (respectively, 24 ± 0.5 μm and 24.8 ± 0.6 μm) in biofilm medium for 72 hours (P = .04). Mean values of microgap size for the Morse taper joints were statistically signicantly lower without fatigue tests (1.7 ± 0.4 μm) than those recorded after fatigue tests (3.2 ± 0.8 μm). Also, mean values of microgap size for external hexagon joints free of fatigue were statistically signicantly lower (1.5 ± 0.4 μm) than those recorded after fatigue tests (8.1 ± 1.7 μm) (P < .05). The optical density of biofilms and CFU mean values were lower on Morse taper abutments (Abs630nm at 0.06 and 2.9 × 10⁴ CFU/cm²) than that on external hexagon abutments (Abs630nm at 0.08 and 4.5 × 10⁴ CFU/cm²) (P = .01). The mean values of removal torque, microgap size, and biofilm density recorded at Morse taper joints were lower in comparison to those recorded at external hexagon

  13. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    PubMed

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  14. Melorheostosis of the hand affecting the c6 sclerotome and presenting with carpal tunnel syndrome

    PubMed Central

    Abdullah, Shalimar; Nor, Noreen Fazlina Mat; Haflah, Nor Hazla Mohamed

    2014-01-01

    Melorheostosis is a rare, progressive bone disease accompanied by hyperostosis and soft tissue fibrosis. While affected adults present with contracture and pain, children present with limb length discrepancy and deformity. We report the case of a 20-year-old woman with melorheostosis since childhood who presented with right hand deformity and numbness. Radiographs showed not only a combination of dense sclerosis and opacities, but also the classic ‘flowing candle wax’ appearance. Radiography can be used to identify melorheostosis, thus preventing unnecessary bone biopsies. Carpal tunnel release revealed the presence of a thickened flexor retinaculum and a degenerated median nerve distal to the retinaculum, but did not show hyperostosis. This case highlights the role of nerve decompression in melorheostosis and the importance of early identification of the disease to prevent unnecessary bone biopsies. PMID:24763843

  15. Melorheostosis of the hand affecting the c6 sclerotome and presenting with carpal tunnel syndrome.

    PubMed

    Abdullah, Shalimar; Mat Nor, Noreen Fazlina; Mohamed Haflah, Nor Hazla

    2014-04-01

    Melorheostosis is a rare, progressive bone disease accompanied by hyperostosis and soft tissue fibrosis. While affected adults present with contracture and pain, children present with limb length discrepancy and deformity. We report the case of a 20-year-old woman with melorheostosis since childhood who presented with right hand deformity and numbness. Radiographs showed not only a combination of dense sclerosis and opacities, but also the classic 'flowing candle wax' appearance. Radiography can be used to identify melorheostosis, thus preventing unnecessary bone biopsies. Carpal tunnel release revealed the presence of a thickened flexor retinaculum and a degenerated median nerve distal to the retinaculum, but did not show hyperostosis. This case highlights the role of nerve decompression in melorheostosis and the importance of early identification of the disease to prevent unnecessary bone biopsies.

  16. Axial displacements in external and internal implant-abutment connection.

    PubMed

    Lee, Ji-Hye; Kim, Dae-Gon; Park, Chan-Jin; Cho, Lee-Ra

    2014-02-01

    The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  17. Impact of distal median neuropathy on handwriting performance for patients with carpal tunnel syndrome in office and administrative support occupations.

    PubMed

    Kuo, Li-Chieh; Hsu, Hsiao-Man; Wu, Po-Ting; Lin, Sheng-Che; Hsu, Hsiu-Yun; Jou, I-Ming

    2014-06-01

    This study investigates the handwriting performance of patients with carpal tunnel syndrome (CTS) and healthy controls in office and administrative support occupations, adopting both biomechanical and functional perspectives. This work also explores how surgical intervention altered the performance of the CTS patients. Fourteen CTS patients and 14 control subjects were recruited to complete a self-reported survey and participate in sensory tests, hand strength, dexterity and handwriting tasks using a custom force acquisition pen along with motion capture technology. Based on the results of these, the sensory measurements, along with functional and biomechanical parameters, were used to determine the differences between the groups and also reveal any improvements that occurred in the CTS group after surgical intervention. The CTS patients showed significantly poorer hand sensibility and dexterity than the controls, as well as excessive force exertion of the digits and pen tip, and less efficient force adjustment ability during handwriting. After surgery and sensory recovery, the hand dexterity and pen tip force of the CTS patients improved significantly. The force adjustment abilities of the digits also increased, but these changes were not statistically significant. This study provides the objective measurements and novel apparatus that can be used to determine impairments in the handwriting abilities of office or administrative workers with CTS. The results can also help clinicians or patients to better understand the sensory-related deficits in sensorimotor control of the hand related to CTS, and thus develop and implement more suitable training or adaptive protocols.

  18. Disabling hand injuries in boxing: boxer's knuckle and traumatic carpal boss.

    PubMed

    Melone, Charles P; Polatsch, Daniel B; Beldner, Steven

    2009-10-01

    This article describes the treatment of the two most debilitating hand-related boxing injuries: boxer's knuckle and traumatic carpal boss. Recognition of the normal anatomy as well as the predictable pathology facilitates an accurate diagnosis and precision surgery. For boxer's knuckle, direct repair of the disrupted extensor hood, without the need for tendon augmentation, has been consistently employed; for traumatic carpal boss, arthrodesis of the destabilized carpometacarpal joints has been the preferred method of treatment. Precisely executed operative treatment of both injuries has resulted in a favorable outcome, as in the vast majority of cases the boxers have experienced relief of pain, restoration of function, and an unrestricted return to competition.

  19. Influence of implant abutment material on the color of different ceramic crown systems.

    PubMed

    Dede, Doğu Ömür; Armağanci, Arzu; Ceylan, Gözlem; Celik, Ersan; Cankaya, Soner; Yilmaz, Burak

    2016-11-01

    Ceramics are widely used for anterior restorations; however, clinical color reproduction still constitutes a challenge particularly when the ceramic crowns are used on titanium implant abutments. The purpose of this in vitro study was to investigate the effect of implant abutment material on the color of different ceramic material systems. Forty disks (11×1.5 mm, shade A2) were fabricated from medium-opacity (mo) and high-translucency (ht) lithium disilicate (IPS e.max) blocks, an aluminous ceramic (VITA In-Ceram Alumina), and a zirconia (Zirkonzahn) ceramic system. Disks were fabricated to represent 3 different implant abutments (zirconia, gold-palladium, and titanium) and dentin (composite resin, A2 shade) as background (11×2 mm). Disk-shaped composite resin specimens in A2 shade were fabricated to represent the cement layer. The color measurements of ceramic specimens were made on composite resin abutment materials using a spectrophotometer. CIELab color coordinates were recorded, and the color coordinates measured on composite resin background served as the control group. Color differences (ΔE 00 ) between the control and test groups were calculated. The data were analyzed with 2-way analysis of variance (ANOVA) and compared with the Tukey HSD test (α=.05). The ceramics system, abutment material, and their interaction were significant for ΔE 00 values (P<.001). Clinically unacceptable results (ΔE 00 >2.25) were observed for lithium disilicate ceramics on titanium abutments (2.46-2.50). The ΔE 00 values of lithium disilicate ceramics for gold-palladium and titanium abutments were significantly higher than for other groups (P<.05). The color results (ΔE 00 >2.25) of an implant-supported lithium disilicate ceramic restoration may be clinically unacceptable if it is fabricated over a titanium abutment. Zirconia may be a more suitable abutment material for implant-supported ceramic restorations. Copyright © 2016 Editorial Council for the Journal of

  20. Non-linear 3D evaluation of different oral implant-abutment connections.

    PubMed

    Streckbein, P; Streckbein, R G; Wilbrand, J F; Malik, C Y; Schaaf, H; Howaldt, H P; Flach, M

    2012-12-01

    Micro-gaps and osseous overload in the implant-abutment connection are the most common causes of peri-implant bone resorption and implant failure. These undesirable events can be visualized on standardized three-dimensional finite element models and by radiographic methods. The present study investigated the influence of 7 available implant systems (Ankylos, Astra, Bego, Brånemark, Camlog, Straumann, and Xive) with different implant-abutment connections on bone overload and the appearance of micro-gaps in vitro. The individual geometries of the implants were transferred to three-dimensional finite element models. In a non-linear analysis considering the pre-loading of the occlusion screw, friction between the implant and abutment, the influence of the cone angle on bone strain, and the appearance of micro-gaps were determined. Increased bone strains were correlated with small (< 15°) cone angles. Conical implant-abutment connections efficiently avoided micro-gaps but had a negative effect on peri-implant bone strain. Bone strain was reduced in implants with greater wall thickness (Ankylos) or a smaller cone angle (Bego). The results of our in silico study provide a solid basis for the reduction of peri-implant bone strain and micro-gaps in the implant-abutment connection to improve long-term stability.

  1. Which nerve conduction parameters can predict spontaneous electromyographic activity in carpal tunnel syndrome?

    PubMed

    Chang, Chia-Wei; Lee, Wei-Ju; Liao, Yi-Chu; Chang, Ming-Hong

    2013-11-01

    We investigate electrodiagnostic markers to determine which parameters are the best predictors of spontaneous electromyographic (EMG) activity in carpal tunnel syndrome (CTS). We enrolled 229 patients with clinically proven and nerve conduction study (NCS)-proven CTS, as well as 100 normal control subjects. All subjects were evaluated using electrodiagnostic techniques, including median distal sensory latencies (DSLs), sensory nerve action potentials (SNAPs), distal motor latencies (DMLs), compound muscle action potentials (CMAPs), forearm median nerve conduction velocities (FMCVs) and wrist-palm motor conduction velocities (W-P MCVs). All CTS patients underwent EMG examination of the abductor pollicis brevis (APB) muscle, and the presence or absence of spontaneous EMG activities was recorded. Normal limits were determined by calculating the means ± 2 standard deviations from the control data. Associations between parameters from the NCS and EMG findings were investigated. In patients with clinically diagnosed CTS, abnormal median CMAP amplitudes were the best predictors of spontaneous activity during EMG examination (p<0.001; OR 36.58; 95% CI 15.85-84.43). If the median CMAP amplitude was ≤ 2.1 mV, the rate of occurrence of spontaneous EMG activity was >95% (positive predictive rate >95%). If the median CMAP amplitude was higher than the normal limit (>4.9 mV), the rate of no spontaneous EMG activity was >94% (negative predictive rate >94%). An abnormal SNAP amplitude was the second best predictor of spontaneous EMG activity (p<0.001; OR 4.13; 95% CI 2.16-7.90), and an abnormal FMCV was the third best predictor (p=0.01; OR 2.10; 95% CI 1.20-3.67). No other nerve conduction parameters had significant power to predict spontaneous activity upon EMG examination. The CMAP amplitudes of the APB are the most powerful predictors of the occurrence of spontaneous EMG activity. Low CMAP amplitudes are strongly associated with spontaneous activity, whereas high CMAP

  2. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening.

    PubMed

    Dincer Kose, Onur; Karataslı, Burcin; Demircan, Sabit; Kose, Taha Emre; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload.

  3. In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening

    PubMed Central

    Demircan, Sabit; Cene, Erhan; Aya, Serhan Aydın; Erdem, Mehmet Ali; Cankaya, Abdulkadir Burak

    2017-01-01

    Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. PMID:28473988

  4. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

    PubMed

    Safari, Sina; Hosseini Ghavam, Fereshteh; Amini, Parviz; Yaghmaei, Kaveh

    2018-02-01

    The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly ( P =.006). The difference in retention between the cemented and recemented copings was not statistically significant ( P =.40). Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

  5. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.

    PubMed

    Stimmelmayr, Michael; Edelhoff, Daniel; Güth, Jan-Frederik; Erdelt, Kurt; Happe, Arndt; Beuer, Florian

    2012-12-01

    The purpose of this study was to determine and measure the wear of the interface between titanium implants and one-piece zirconia abutments in comparison to titanium abutments. 6 implants were secured into epoxy resin blocks. The implant interface of these implants and 6 corresponding abutments (group Zr: three one-piece zirconia abutments; group Ti: three titanium abutments) were examined by a microscope and scanning electron micrograph (SEM). Also the implants and the abutments were scanned by 3D-Micro Computer Tomography (CT). The abutments were connected to the implants and cyclically loaded with 1,200,000 cycles at 100N in a two-axis fatigue testing machine. Afterwards, all specimens were unscrewed and the implants and abutments again were scanned by microscope, SEM and CT. The microscope and SEM images were compared, the CT data were superimposed and the wear was calculated by inspection software. The statistical analysis was carried out with an unpaired t-test. Abutment fracture or screw loosening was not observed during cyclical loading. Comparing the microscope and SEM images more wear was observed on the implants connected to zirconia abutments. The maximum wear on the implant shoulder calculated by the inspection software was 10.2μm for group Zr, and 0.7μm for group Ti. The influence of the abutment material on the measured wear was statistically significant (p≤0.001; Levene-test). Titanium implants showed higher wear at the implant interface following cyclic loading when connected to one-piece zirconia implant abutments compared to titanium abutments. The clinical relevance is not clear; hence damage of the internal implant connection could result in prosthetic failures up to the need of implant removal. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Pressure pain sensitivity topographical maps reveal bilateral hyperalgesia of the hands in patients with unilateral carpal tunnel syndrome.

    PubMed

    Fernández-de-Las-Peñas, César; Madeleine, Pascal; Martínez-Perez, Almudena; Arendt-Nielsen, Lars; Jiménez-García, Rodrigo; Pareja, Juan A

    2010-08-01

    To assess topographical pressure pain sensitivity maps of the hand in patients with unilateral carpal tunnel syndrome (CTS) as compared with healthy subjects. A total of 20 women with CTS (ages 32-52 years) and 20 healthy matched women (ages 32-51 years) were recruited. Pressure pain thresholds (PPTs) were measured bilaterally over 30 locations of the palm of each hand by an assessor blinded to the subjects' conditions. Patients showed lower PPTs in both hands in all of the measurement points as compared with controls (P < 0.001 for all). PPTs were lower in those points over the proximal phalanx of the fingers and the thenar eminency as compared with those points located over the distal phalanx of the fingers (P < 0.001). CTS patients showed lower PPT levels in dermatomes C6, C7, and C8 when compared with healthy controls (P < 0.001 for all), but without differences between dermatomes (P = 0.4). PPT was negatively correlated with both hand pain intensity and duration of symptoms (P < 0.001 for all). Our findings revealed bilateral generalized pressure pain hyperalgesia in unilateral CTS because lower PPT levels were found in all of the points. The pressure pain hyperalgesia was not uniformly distributed since PPTs were lower in points over the proximal phalanx of the fingers and the thenar eminency as compared with those points located over the distal phalanx of the fingers. The decrease in PPT levels was associated with the intensity and the duration of the pain symptoms, supporting a role of both peripheral and central sensitization mechanisms in this pain condition.

  7. [A computer aided design approach of all-ceramics abutment for maxilla central incisor].

    PubMed

    Sun, Yu-chun; Zhao, Yi-jiao; Wang, Yong; Han, Jing-yun; Lin, Ye; Lü, Pei-jun

    2010-10-01

    To establish the computer aided design (CAD) software platform of individualized abutment for the maxilla central incisor. Three-dimentional data of the incisor was collected by scanning and geometric transformation. Data mainly included the occlusal part of the healing abutment, the location carinae of the bedpiece, the occlusal 1/3 part of the artificial gingiva's inner surface, and so on. The all-ceramic crown designed in advanced was "virtual cutback" to get the original data of the abutment's supragingival part. The abutment's in-gum part was designed to simulate the individual natural tooth root. The functions such as "data offset", "bi-rail sweep surface" and "loft surface" were used in the process of CAD. The CAD route of the individualized all-ceramic abutment was set up. The functions and application methods were decided and the complete CAD process was realized. The software platform was basically set up according to the requests of the dental clinic.

  8. Influence of abutment materials on the resultant color of heat-pressed lithium disilicate ceramics.

    PubMed

    Shimada, Kazuki; Nakazawa, Motoko; Kakehashi, Yoshiyuki; Matsumura, Hideo

    2006-03-01

    The purpose of this study was to evaluate the influence of abutment materials on the color of IPS Empress 2 ceramic coping with different thicknesses. Ceramic coping specimens (12.0x12.0x0.8-2.0 mm) were fabricated from IPS Empress 2 material (Ingot-100, n=5/group). Abutment specimens were fabricated from a build-up composite, a gold alloy, or a silver-palladium alloy. Color was evaluated using a colorimeter according to the CIE L*a*b* system. The L*a*b* values of the ceramic coping specimens of different thicknesses on each abutment specimen were measured. Following which, the color difference (deltaE*ab) values between the ceramic coping specimens on various abutment specimens were calculated. Significant differences in deltaE*ab value were observed among different abutment specimens at certain ceramic coping thicknesses (P<0.05). Thus, it was concluded that the color of IPS Empress 2 coping material was influenced significantly by both the thickness of the coping and the color of the abutment material.

  9. Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis

    PubMed Central

    ElHoussiney, Amr G; Zhang, He; Song, Jinlin; Ji, Ping; Wang, Lu; Yang, Sheng

    2018-01-01

    Purpose To compare the failure events and incidence of complications of different abutment materials in anterior and posterior regions. Failure was defined as complete loss of the abutment requiring replacement by a new abutment. Materials and methods Electronic searches using PubMed/Medline and Google Scholar complemented with manual searches were performed with specific search terms. Searches were restricted to publications in English between January 2006 and March 2016. Results A total of 863 and 1,264 implants were inserted in the anterior and posterior regions, respectively, in a total of 1,529 patients. No titanium abutments failed in anterior or posterior regions. On the other hand, 1.6% of zirconia abutments failed in the anterior region and 1.5% failed in the posterior region. Technical complications occurred mostly in the posterior region and mostly involved zirconia abutment. Meta-analysis was possible only for zirconia-abutment failure, due to considerable heterogeneity of studies and outcome variables. No significant difference in failure rate was found between anterior and posterior zirconia abutments (risk ratio 1.53, 95% CI 0.49–4.77; P=0.47). Conclusion This systematic review and meta-analysis showed similar outcomes of different abutment materials when used in anterior and posterior regions in terms of failure events and biological and aesthetic complications. The only significant finding was the increased incidence of technical complications in the posterior region, mostly involving zirconia abutments. Abutment-screw loosening was the most common technical complication. PMID:29520162

  10. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    PubMed

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2

  11. Soil-structure interaction studies for understanding the behavior of integral abutment bridges.

    DOT National Transportation Integrated Search

    2012-03-01

    Integral Abutment Bridges (IAB) are bridges without any joints within the bridge deck or between the : superstructure and the abutments. An IAB provides many advantages during construction and maintenance of : a bridge. Soil-structure interactions at...

  12. The effect of repeated torque in small diameter implants with machined and premachined abutments.

    PubMed

    Saboury, Abolfazl; Neshandar Asli, Hamid; Vaziri, Shahram

    2012-05-01

    Detorquing value is an important factor in the amount of preload stresses during abutment screw fastening. This study evaluated the percentage of detorque values in two-piece machined titanium and premachined cast abutments in small diameter implants. Three groups of five samples were evaluated. Group 1 (G1), machined titanium abutments, group 2 (G2), premachined cast straight abutments that cast with gold-palladium, and group 3 (G3), premachined angled cast abutments that cast with the same alloy, were angled before casting. Each abutment was torque to 24 Ncm according to the manufacturer's instructions and detorqued five times. The means of detorquing and torquing values in all groups were recorded. The mean of detorque in each group as a percentage of the toque value was calculated. The data for all groups were compared and calculated using analysis of variance (ANOVA) and t-test. Mean detorque values in G1, G2, and G3 were 88.1 ± 1.69, 93.1 ± 2.68, and 80.9 ± 4.95%, respectively. The ANOVA showed significant differences in mean of applied detorque (p < .001) and torque (p = .06) tightening among different groups. G2 had significantly greater detorque values (p < .05). No significant differences were found between G1 and G2. Surprisingly, abutment screw fracture occurred in three samples of G3. G3 showed significant percentage torque reduction (p < .05) and exhibited abutment screw fracture during evaluation. G2 presented the lowest torque reduction. Screw fracture occurred only in G3. © 2012 Wiley Periodicals, Inc.

  13. A novel dental implant abutment with micro-motion capability--development and biomechanical evaluations.

    PubMed

    Chen, Yen-Yin; Chen, Weng-Pin; Chang, Hao-Hueng; Huang, Shih-Hao; Lin, Chun-Pin

    2014-02-01

    The aim of this study was to develop a novel dental implant abutment with a micro-motion mechanism that imitates the biomechanical behavior of the periodontal ligament, with the goal of increasing the long-term survival rate of dental implants. Computer-aided design software was used to design a novel dental implant abutment with an internal resilient component with a micro-motion capability. The feasibility of the novel system was investigated via finite element analysis. Then, a prototype of the novel dental implant abutment was fabricated, and the mechanical behavior was evaluated. The results of the mechanical tests and finite element analysis confirmed that the novel dental implant abutment possessed the anticipated micro-motion capability. Furthermore, the nonlinear force-displacement behavior apparent in this micro-motion mechanism imitated the movement of a human tooth. The slope of the force-displacement curve of the novel abutment was approximately 38.5 N/mm before the 0.02-mm displacement and approximately 430 N/mm after the 0.03-mm displacement. The novel dental implant abutment with a micro-motion mechanism actually imitated the biomechanical behavior of a natural tooth and provided resilient function, sealing, a non-separation mechanism, and ease-of-use. Copyright © 2013 Academy of Dental Materials. All rights reserved.

  14. In Vitro Microbiological Analysis of Bacterial Seal in Hybrid Zirconia Abutment Tapered Connection.

    PubMed

    Harlos, Maurício Marcelo; Bezerra da Silva, Thiago; Peruzzo, Daiane C; Napimoga, Marcelo H; Joly, Julio Cesar; Martinez, Elizabeth F

    2017-04-01

    The aim of this study was to evaluate the bacterial seal at the implant-hybrid zirconia abutment interface and Morse taper-type connections through in vitro microbiological analysis. Sixteen implants and their respective abutments were divided into 3 groups: test (10 sets), positive control (3 sets), and negative control (3 sets). In the test group, 10 implants were contaminated with Escherichia coli using a sterile inoculating loop to the inner portion of the implants, followed by torque application to the abutment (30 N·cm). The positive controls were also contaminated, but no torque was applied to the abutment screw. The negative control consisted of uncontaminated sets. All specimens were immersed in test tubes containing 5 mL brain heart infusion (BHI) broth, maintained in a microbiological incubator for 14 days at 37°C under aerobic conditions, and monitored every 24 hours for evidence of bacterial growth. During the 14 days of incubation, no significant increase in the number of cloudy culture media was observed in the test group (P = 0.448). No significant difference in broth turbidity ratio was observed (P > 0.05). Hybrid zirconia abutments can create an effective seal at the tapered abutment-implant interface with a 30-N·cm installation torque.

  15. Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss

    PubMed Central

    2013-01-01

    Background Zirconia materials are known for their optimal aesthetics, but they are brittle, and concerns remain about whether their mechanical properties are sufficient for withstanding the forces exerted in the oral cavity. Therefore, this study compared the maximum deformation and failure forces of titanium implants between titanium-alloy and zirconia abutments under oblique compressive forces in the presence of two levels of marginal bone loss. Methods Twenty implants were divided into Groups A and B, with simulated bone losses of 3.0 and 1.5 mm, respectively. Groups A and B were also each divided into two subgroups with five implants each: (1) titanium implants connected to titanium-alloy abutments and (2) titanium implants connected to zirconia abutments. The maximum deformation and failure forces of each sample was determined using a universal testing machine. The data were analyzed using the nonparametric Mann–Whitney test. Results The mean maximum deformation and failure forces obtained the subgroups were as follows: A1 (simulated bone loss of 3.0 mm, titanium-alloy abutment) = 540.6 N and 656.9 N, respectively; A2 (simulated bone loss of 3.0 mm, zirconia abutment) = 531.8 N and 852.7 N; B1 (simulated bone loss of 1.5 mm, titanium-alloy abutment) = 1070.9 N and 1260.2 N; and B2 (simulated bone loss of 1.5 mm, zirconia abutment) = 907.3 N and 1182.8 N. The maximum deformation force differed significantly between Groups B1 and B2 but not between Groups A1 and A2. The failure force did not differ between Groups A1 and A2 or between Groups B1 and B2. The maximum deformation and failure forces differed significantly between Groups A1 and B1 and between Groups A2 and B2. Conclusions Based on this experimental study, the maximum deformation and failure forces are lower for implants with a marginal bone loss of 3.0 mm than of 1.5 mm. Zirconia abutments can withstand physiological occlusal forces applied in the anterior region. PMID

  16. Abutment tooth loss in patients with overdentures.

    PubMed

    Ettinger, Ronald L; Qian, Fang

    2004-06-01

    Since the 1960s, the use of natural teeth as overdenture abutments has become part of accepted clinical practice. Several longitudinal studies have been conducted, but tooth loss has not been reported to be a significant problem. The aim of this study was to identify the incidence and causes of tooth loss in a prospective cohort study of subjects wearing overdentures. The study, conducted between 1973 and 1994, evaluated 273 subjects (62.3 percent male) with a mean age of 59.6 years. Of the 273 subjects with 666 abutments, 74 lost 133 abutments. The most common cause of tooth loss was periodontal disease (29.3 percent) followed by periapical lesions (18.8 percent) and caries (16.5 percent). Through logistic regression, the authors found that subjects who lost teeth were more likely to have medical problems that could cause soft-tissue lesions of the oral mucosa, were less likely to use fluoride daily and were less likely to return for yearly recall visits. The authors found 22 vertical fractures in 17 subjects. Chi2 analysis revealed that overdenture teeth in the maxillary arch that were opposed by natural teeth were more likely to experience vertical fractures. In a study that followed up some patients for as long as 22 years, the rate of tooth loss was 20.0 percent. Many of these failures could have been prevented if patients had practiced better oral hygiene. The findings suggest that if a dentist recommends overdenture therapy, the patient needs to be examined regularly to reduce the risk of experiencing caries and periodontal disease. Also, if the abutments are in the maxilla and are opposed by natural teeth, the dentist should consider using thimble crowns to reduce the risk of vertical fractures.

  17. Investigating the micromorphological differences of the implant-abutment junction and their clinical implications: a pilot study.

    PubMed

    Mattheos, Nikos; Li, Xiaona; Zampelis, Antonios; Ma, Li; Janda, Martin

    2016-11-01

    The aim of this pilot study was to investigate the morphological micro-features of three commercially available implant-abutment joints, using compatible and original prosthetic components. Furthermore, possible correlations between the micromorphology and potential functional complications were investigated with the use of finite element analysis. Three abutments (one original and two compatibles) were torqued on original Straumann RN implants, as according to each of the manufacturer's instructions. The implant-abutment units were sliced in the microtome and photographed under different magnifications (10×-500×) through a scanning electron microscope. Finite element analysis models were reconstructed for each of the implant-abutment units using the precise measurements from the SEM. Differences in stress, strain and deformation for the three different abutments were then calculated using ANSYS Workbench v13. Major dimensional differences were identified between all studied contact areas of the three units. The tight contact in the implant shoulder was similar in all three units, but engagement of the internal connection and, in particular, the anti-rotation elements was seriously compromised in the compatible abutments. One compatible abutment demonstrated compromised engagement of the abutment screw as well. Equivalent stress and strain in the FEA were much higher for the compatible abutments. An evaluation of the sequence of preload application revealed differences in the pattern of deformation between the original and compatible abutments, which can have serious clinical implications. Compatible abutments can present critical morphological differences from the original ones. The differences in the cross-sectional geometry result in large differences in the overall contact areas, both in terms of quality and quantity which could have serious implications for the long-term stability of the prosthesis. © 2015 John Wiley & Sons A/S. Published by John Wiley

  18. Retention of cast crown copings cemented to implant abutments.

    PubMed

    Dudley, J E; Richards, L C; Abbott, J R

    2008-12-01

    The cementation of crowns to dental implant abutments is an accepted form of crown retention that requires consideration of the properties of available cements within the applied clinical context. Dental luting agents are exposed to a number of stressors that may reduce crown retention in vivo, not the least of which is occlusal loading. This study investigated the influence of compressive cyclic loading on the physical retention of cast crown copings cemented to implant abutments. Cast crown copings were cemented to Straumann synOcta titanium implant abutments with three different readily used and available cements. Specimens were placed in a humidifier, thermocycled and subjected to one of four quantities of compressive cyclic loading. The uniaxial tensile force required to remove the cast crown copings was then recorded. The mean retention values for crown copings cemented with Panavia-F cement were statistically significantly greater than both KetacCem and TempBond non-eugenol cements at each compressive cyclic loading quantity. KetacCem and TempBond non-eugenol cements produced relatively low mean retention values that were not statistically significantly different at each quantity of compressive cyclic loading. Compressive cyclic loading had a statistically significant effect on Panavia-F specimens alone, but increased loading quantities produced no further statistically significant difference in mean retention. Within the limitations of the current in vitro conditions employed in this study, the retention of cast crown copings cemented to Straumann synOcta implant abutments with a resin, glass ionomer and temporary cement was significantly affected by cement type but not compressive cyclic loading. Resin cement is the cement of choice for the definitive non-retrievable cementation of cast crown copings to Straumann synOcta implant abutments out of the three cements tested.

  19. Bacterial microleakage at the abutment-implant interface, in vitro study.

    PubMed

    Larrucea, Carlos; Conrado, Aparicio; Olivares, Denise; Padilla, Carlos; Barrera, Andrea; Lobos, Olga

    2018-02-15

    In implant rehabilitation, a microspace is created at the abutment-implant interface (AII). Previous research has shown that oral microbiome can proliferate in this microspace and affect periimplant tissues, causing inflammation in peri-implant tissues. Preventing microbial leakages through the AII is therefore an important goal in implantology. To determine the presence of marginal bacterial microleakage at the AII according to the torque applied to the prosthetic implant in vitro. Twenty-five Ticare Inhex internal conical implants (MG Mozo-Grau, Valladolid, España) were connected to a prosthetic abutment using torques of <10, 10, 20, 30, and 30 N and then sealed. The samples were submitted to cycles of occlusal loads and thermocycling, then one sample of each group was observed by micro TC, while the rest were mounted on devices according to the bacterial leakage model with Porphyromonas gingivalis. Bacterial leakage was observed only in the <10 and 10 N torque samples, and the same groups presented poor abutment/implant adjustment as determined by micro-CT. The different torques applied to the abutment-implant system condition the bacterial leakage at the implant interface. No microleakage was observed at 20 and 30 N. © 2018 Wiley Periodicals, Inc.

  20. Salvaging an angled implant abutment with damaged internal threads: a clinical report.

    PubMed

    Imam, Ahmad Y; Yilmaz, Burak; Özçelik, Tuncer Burak; McGlumphy, Edwin

    2013-05-01

    This clinical report describes a technique to fit an existing fixed detachable implant-supported prosthesis to a zygomatic implant abutment with stripped internal threads. The threads of the abutment were retapped and a wide diameter/wide head retaining screw was used to secure the existing prosthesis on the abutment. Care is needed in the retrieval of broken screws so as not to damage the internal threads of the implants, which might lead to irreversible complications. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

    PubMed Central

    Safari, Sina; Amini, Parviz; Yaghmaei, Kaveh

    2018-01-01

    PURPOSE The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). RESULTS The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement. PMID:29503708

  2. Assessment of reliability of CAD-CAM tooth-colored implant custom abutments.

    PubMed

    Guilherme, Nuno Marques; Chung, Kwok-Hung; Flinn, Brian D; Zheng, Cheng; Raigrodski, Ariel J

    2016-08-01

    Information is lacking about the fatigue resistance of computer-aided design and computer-aided manufacturing (CAD-CAM) tooth-colored implant custom abutment materials. The purpose of this in vitro study was to investigate the reliability of different types of CAD-CAM tooth-colored implant custom abutments. Zirconia (Lava Plus), lithium disilicate (IPS e.max CAD), and resin-based composite (Lava Ultimate) abutments were fabricated using CAD-CAM technology and bonded to machined titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy inserts for conical connection implants (NobelReplace Conical Connection RP 4.3×10 mm; Nobel Biocare). Three groups (n=19) were assessed: group ZR, CAD-CAM zirconia/Ti-6Al-4V bonded abutments; group RC, CAD-CAM resin-based composite/Ti-6Al-4V bonded abutments; and group LD, CAD-CAM lithium disilicate/Ti-6Al-4V bonded abutments. Fifty-seven implant abutments were secured to implants and embedded in autopolymerizing acrylic resin according to ISO standard 14801. Static failure load (n=5) and fatigue failure load (n=14) were tested. Weibull cumulative damage analysis was used to calculate step-stress reliability at 150-N and 200-N loads with 2-sided 90% confidence limits. Representative fractured specimens were examined using stereomicroscopy and scanning electron microscopy to observe fracture patterns. Weibull plots revealed β values of 2.59 for group ZR, 0.30 for group RC, and 0.58 for group LD, indicating a wear-out or cumulative fatigue pattern for group ZR and load as the failure accelerating factor for groups RC and LD. Fractographic observation disclosed that failures initiated in the interproximal area where the lingual tensile stresses meet the compressive facial stresses for the early failure specimens. Plastic deformation of titanium inserts with fracture was observed for zirconia abutments in fatigue resistance testing. Significantly higher reliability was found in group ZR, and no significant differences in reliability were

  3. A fuzzy linguistic model for the prediction of carpal tunnel syndrome risks in an occupational environment.

    PubMed

    Bell, P M; Crumpton, L

    1997-08-01

    This research presents the development and evaluation of a fuzzy linguistic model designated to predict the risk of carpal tunnel syndrome (CTS) in an occupational setting. CTS has become one of the largest problems facing ergonomists and the medical community because it is developing in epidemic proportions within the occupational environment. In addition, practitioners are interested in identifying accurate methods for evaluating the risk of CTS in an occupational setting. It is hypothesized that many factors impact an individual's likelihood of developing CTS and the eventual development of CTS. This disparity in the occurrence of CTS for workers with similar backgrounds and work activities has confused researchers and has been a stumbling block in the development of a model for widespread use in evaluating the development of CTS. Thus this research is an attempt to develop a method that can be used to predict the likelihood of CTS risk in a variety of environments. The intent is that this model will be applied eventually in an occupational setting, thus model development was focused on a method that provided a usable interface and the desired system inputs can also be obtained without the benefit of a medical practitioner. The methodology involves knowledge acquisition to identify and categorize a holistic set of risk factors that include task-related, personal, and organizational categories. The determination of relative factor importance was accomplished using analytic hierarchy processing (AHP) analysis. Finally a mathematical representation of the CTS risk was accomplished by utilizing fuzzy set theory in order to quantify linguistic input parameters. An evaluation of the model including determination of sensitivity and specificity is conducted and the results of the model indicate that the results are fairly accurate and this method has the potential for widespread use. A significant aspect of this research is the comparison of this technique to other

  4. Theoretical impact of simulated workplace-based primary prevention of carpal tunnel syndrome in a French region.

    PubMed

    Roquelaure, Yves; Fouquet, Natacha; Chazelle, Emilie; Descatha, Alexis; Evanoff, Bradley; Bodin, Julie; Petit, Audrey

    2018-04-02

    Carpal tunnel syndrome (CTS) is the most common nerve entrapment neuropathy in the working-age population. The reduction of CTS incidence in the workforce is a priority for policy makers due to the human, social and economic costs. To assess the theoretical impact of workplace-based primary interventions designed to reduce exposure to personal and/or work-related risk factors for CTS. Surgical CTS were assessed using regional hospital discharge records for persons aged 20-59 in 2009. Using work-related attributable fractions (AFEs), we estimated the number of work-related CTS (WR-CTS) in high-risk jobs. We simulated three theoretical scenarios of workplace-based primary prevention for jobs at risk: a mono-component work-centered intervention reducing the incidence of WR-CTS arbitrarily by 10% (10%-WI), and multicomponent global interventions reducing the incidence of all surgical CTS by 5% and 10% by targeting personal and work risk factors. A limited proportion of CTS were work-related in the region's population. WR-CTS were concentrated in nine jobs at high risk of CTS, amounting to 1603 [1137-2212] CTS, of which 906 [450-1522] were WR-CTS. The 10%-WI, 5%-GI and 10%-GI hypothetically prevented 90 [46-153], 81 [58-111] and 159 [114-223] CTS, respectively. The 10%-GI had the greatest impact regardless of the job. The impact of the 10%-WI interventions was high only in jobs at highest risk and AFEs (e.g. food industry jobs). The 10%-WI and 5%-GI had a similar impact for moderate-risk jobs (e.g. healthcare jobs). The impact of simulated workplace-based interventions suggests that prevention efforts to reduce exposure to work-related risk factors should focus on high-risk jobs. Reducing CTS rates will also require integrated strategies to reduce personal risk factors, particularly in jobs with low levels of work-related risk of CTS.

  5. Patients With Limited Health Literacy Have Similar Preferences but Different Perceptions in Surgical Decision-making for Carpal Tunnel Release.

    PubMed

    Roh, Young Hak; Koh, Young Do; Kim, Jong Oh; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2018-04-01

    Health literacy is the ability to obtain, process, and understand health information needed to make appropriate health decisions. The proper comprehension by patients regarding a given disease, its treatment, and the physician's instructions plays an important role in shared decision-making. Studies have disagreed over the degree to which differences in health literacy affect patients' preferences for shared decision-making; we therefore sought to evaluate this in the context of shared decision-making about carpal tunnel release. (1) Do patients with limited health literacy have different preferences of shared decision-making for carpal tunnel release than those with greater levels of health literacy? (2) How do patients with limited health literacy retrospectively perceive their role in shared decision-making after carpal tunnel release? Over a 32-month period, one surgeon surgically treated 149 patients for carpal tunnel syndrome. Patients were eligible if they had cognitive and language function to provide informed consent and complete a self-reported questionnaire and were not eligible if they had nerve entrapment other than carpal tunnel release or had workers compensation issues; based on those, 140 (94%) were approached for study. Of those, seven (5%) were lost to followup before 6 months, leaving 133 for analysis here. Their mean age was 55 years (range, 31-76 years), and 83% (111 of 133) were women. Thirty-three percent (44 of 133) of patients had less than a high school education. Health literacy was measured according to the Newest Vital Sign during the initial visit, and a score of ≤ 3 was considered limited health literacy. Forty-four percent of patients had limited health literacy. The Control Preferences Scale was used for patients to indicate their preferred role in surgical decision-making preoperatively and to assess their perceived level of involvement postoperatively. Bivariate and multivariable analyses were performed to determine whether

  6. Comparison of Observed and Predicted Abutment Scour at Selected Bridges in Maine

    USGS Publications Warehouse

    Lombard, Pamela J.; Hodgkins, Glenn A.

    2008-01-01

    Maximum abutment-scour depths predicted with five different methods were compared to maximum abutment-scour depths observed at 100 abutments at 50 bridge sites in Maine with a median bridge age of 66 years. Prediction methods included the Froehlich/Hire method, the Sturm method, and the Maryland method published in Federal Highway Administration Hydraulic Engineering Circular 18 (HEC-18); the Melville method; and envelope curves. No correlation was found between scour calculated using any of the prediction methods and observed scour. Abutment scour observed in the field ranged from 0 to 6.8 feet, with an average observed scour of less than 1.0 foot. Fifteen of the 50 bridge sites had no observable scour. Equations frequently overpredicted scour by an order of magnitude and in some cases by two orders of magnitude. The equations also underpredicted scour 4 to 14 percent of the time.

  7. Mechanical behavior of single-layer ceramized zirconia abutments for dental implant prosthetic rehabilitation

    PubMed Central

    Jiménez-Melendo, Manuel; Llena-Blasco, Oriol; Bruguera, August; Llena-Blasco, Jaime; Yáñez-Vico, Rosa-María; García-Calderón, Manuel; Vaquero-Aguilar, Cristina; Velázquez-Cayón, Rocío; Gutiérrez-Pérez, José-Luis

    2014-01-01

    Objectives: This study was undertaken to characterize the mechanical response of bare (as-received) and single-layer ceramized zirconia abutments with both internal and external connections that have been developed to enhanced aesthetic restorations. Material and Methods: Sixteen zirconia implant abutments (ZiReal Post®, Biomet 3i, USA) with internal and external connections have been analyzed. Half of the specimens were coated with a 0.5mm-thick layer of a low-fusing fluroapatite ceramic. Mechanical tests were carried out under static (constant cross-head speed of 1mm/min until fracture) and dynamic (between 100 and 400N at a frequency of 1Hz) loading conditions. The failure location was identified by electron microscopy. The removal torque of the retaining screws after testing was also evaluated. Results: The average fracture strength was above 300N for all the abutments, regardless of connection geometry and coating. In most of the cases (94%), failure occurred by abutment fracture. No significant differences were observed either in fatigue behavior and removal torque between the different abutment groups. Conclusions: Mechanical behavior of Zireal zirconia abutments is independent of the type of internal/external connection and the presence/absence of ceramic coating. This may be clinically valuable in dental rehabilitation to improve the aesthetic outcome of zirconia-based dental implant systems. Key words:Dental implant, zirconia, ceramic structure, mechanical properties. PMID:25674313

  8. Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals.

    PubMed

    Al-Keraidis, Abdullah; Aleisa, Khalil; Al-Dwairi, Ziad Nawaf; Al-Tahawi, Hamdi; Hsu, Ming-Lun; Lynch, Edward; Özcan, Mutlu

    2017-10-01

    The purpose of this study was to evaluate heat generation at the implant surface caused by abutment preparation using a diamond bur in a high-speed dental turbine in vitro at 2 different water-coolant temperatures. Thirty-two titanium-alloy abutments were connected to a titanium-alloy implant embedded in an acrylic resin placed within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each). Group 1: the temperature was maintained at 20 ± 1°C; and group 2: the temperature was maintained at 32 ± 1°C. Each abutment was prepared in the axial plane for 1 minute and in the occlusal plane for 1 minute. The temperature of the heat generated from abutment preparation was recorded and measured at 3 distinct time intervals. Water-coolant temperature (20°C vs 32°C) had a statistically significant effect on the implant's temperature change during preparation of the abutment (P < 0.0001). The use of water-coolant temperature of 20 ± 1°C during preparation of the implant abutment decreased the temperature recorded at the implant surface to 34.46°C, whereas the coolant temperature of 32 ± 1°C increased the implant surface temperature to 40.94°C.

  9. Leakage evaluation of original and compatible implant–abutment connections: In vitro study using Rhodamine B

    PubMed Central

    Tehini, George; Rifai, Khaldoun; Bou Nasser Eddine, Farah; Badran, Bassam; Akl, Haidar

    2014-01-01

    Leakage has been addressed as a major contributing factor to inflammatory reactions at the implant–abutment connection, leading to problems such as oral malodor, inflammation, and marginal bone loss. The aim of this study was to investigate in vitro the leakage at implant–abutment interface of OsseoSpeed™ implants connected to original and compatible abutments. A total of 28 OsseoSpeed implants were divided into four groups (n = 7). Each group was connected to four different abutments according to manufacturers’ recommendations: group A (TiDesign™); group B (Natea™); group C (Dual™); and group D (Implanet™) abutments. The inner volume of each implant–abutment combination was calculated and leakage was detected for each group with spectrophotometric analysis at 1 h (D0) and 48 h (D1) of incubation time using Rhodamine B. At 1 h, leakage volume was significantly lower in TiDesign and Dual than in Natea and Implanet (P < 0.001). At 48 h, however, leakage was significantly lower between TiDesign and all other systems (P < 0.005). Compatible abutments do not fit internal connection of OsseoSpeed implants perfectly, which increases the leakage of the final assembly. PMID:25342984

  10. Marginal Bone Remodeling around healing Abutment vs Final Abutment Placement at Second Stage Implant Surgery: A 12-month Randomized Clinical Trial.

    PubMed

    Nader, Nabih; Aboulhosn, Maissa; Berberi, Antoine; Manal, Cordahi; Younes, Ronald

    2016-01-01

    The periimplant bone level has been used as one of the criteria to assess the success of dental implants. It has been documented that the bone supporting two-piece implants undergoes resorption first following the second-stage surgery and later on further to abutment connection and delivery of the final prosthesis. The aim of this multicentric randomized clinical trial was to evaluate the crestal bone resorption around internal connection dental implants using a new surgical protocol that aims to respect the biological distance, relying on the benefit of a friction fit connection abutment (test group) compared with implants receiving conventional healing abutments at second-stage surgery (control group). A total of partially edentulous patients were consecutively treated at two private clinics, with two adjacent two-stage implants. Three months after the first surgery, one of the implants was randomly allocated to the control group and was uncovered using a healing abutment, while the other implant received a standard final abutment and was seated and tightened to 30 Ncm. At each step of the prosthetic try-in, the abutment in the test group was removed and then retightened to 30 Ncm. Horizontal bone changes were assessed using periapical radiographs immediately after implant placement and at 3 (second-stage surgery), 6, 9 and 12 months follow-up examinations. At 12 months follow-up, no implant failure was reported in both groups. In the control group, the mean periimplant bone resorption was 0.249 ± 0.362 at M3, 0.773 ± 0.413 at M6, 0.904 ± 0.36 at M9 and 1.047 ± 0.395 at M12. The test group revealed a statistically significant lower marginal bone loss of 20.88% at M3 (0.197 ± 0.262), 22.25% at M6 (0.601 ± 0.386), 24.23% at M9 (0.685 ± 0.341) and 19.2% at M9 (0.846 ± 0.454). The results revealed that bone loss increased over time, with the greatest change in bone loss occurring between 3 and 6 months. Alveolar bone loss was significantly greater in the

  11. Transforming growth factor-β (TGF-β) expression is increased in the subsynovial connective tissues of patients with idiopathic carpal tunnel syndrome.

    PubMed

    Chikenji, Takako; Gingery, Anne; Zhao, Chunfeng; Passe, Sandra M; Ozasa, Yasuhiro; Larson, Dirk; An, Kai-Nan; Amadio, Peter C

    2014-01-01

    Non-inflammatory fibrosis of the subsynovial connective tissue (SSCT) is a hallmark of carpal tunnel syndrome (CTS). The etiology of this finding and its relationship to the development of CTS remain poorly understood. Recent studies have found that transforming growth factor-β (TGF-β) plays a central role in fibrosis. The purpose of this study was to investigate the expression of TGF-β and connective tissue growth factor (CTGF), a downstream mediator of TGF-β, in the pathogenesis of CTS. We compared SSCT specimens from 26 idiopathic CTS patients with specimens from 10 human cadaver controls with no previous diagnosis of CTS. Immunohistochemistry was performed to determine levels TGF-β1, CTGF, collagen 1(Col1) and collagen 3 (Col3) expression. TGF-β1 (p < 0.01), CTGF (p < 0.01), and Col3 (p < 0.01) were increased in SSCT of CTS patients compared with control tissue. In addition, a strong positive correlation was found between TGF-β1 and CTGF, (R(2) = 0.80, p < 0.01) and a moderate positive correlation between Col3 and TGF-β1 (R(2) = 0.49, p < 0.01). These finding suggest that there is an increased expression of TGF-β and CTGF, a TGF-β regulated protein, and that this TGF-β activation may be responsible for SSCT fibrosis in CTS patients. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Carpal height and postoperative strength after proximal row carpectomy or four-corner arthrodesis: Clinical, anatomical and biomechanical study.

    PubMed

    Laronde, Pascale; Christiaens, Nicolas; Aumar, Aurélien; Chantelot, Christophe; Fontaine, Christian

    2016-04-01

    Proximal row carpectomy (PRC) and four-corner arthrodesis (4CA) are the two most commonly performed surgical procedures to treat wrist arthritis. Postoperative strength is one of the criteria for choosing between the two techniques. Some authors believe that strength is correlated with residual carpal height. The goal of this study was to determine if postoperative carpal height was predictive of postoperative strength. This study consisted of two parts: a clinical evaluation of grip strength after 4CA or PRC; anatomical and radiological measurements of carpal height before and after 4CA or PRC. Grip strength was better preserved after PRC (87.5%) than after 4CA (76.1%), when expressed relative to the opposite hand (P=0.053). There was a significant decrease in carpal height for the PRC group with a Youm's index of 0.37 versus 0.50 for the 4CA group (P<0.0001). Our clinical results and analysis of the literature indicate that 4CA is not superior to PRC when it comes to grip strength, whereas carpal height is significantly decreased after PRC. The decreased tendon excursion after PRC is balanced by an increase in joint stresses after 4CA. Copyright © 2016 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  13. Influence of implant abutment material and ceramic thickness on optical properties.

    PubMed

    Jirajariyavej, Bundhit; Wanapirom, Peeraphorn; Anunmana, Chuchai

    2018-05-01

    Anterior shade matching is an essential factor influencing the esthetics of a ceramic restoration. Dentists face a challenge when the color of an implant abutment creates an unsatisfactory match with the ceramic restoration or neighboring teeth. The purpose of this in vitro study was to evaluate the influence of abutment material and ceramic thickness on the final color of different ceramic systems. Four experimental and control ceramic specimens in shade A3 were cut from IPS e.max CAD, IPS Empress CAD, and VITA Suprinity PC blocks. These specimens had thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, and 2.5 mm, respectively, for the experimental groups, and 4 mm for the controls. Background abutment specimens were fabricated to yield 3 different shades: white zirconia, yellow zirconia, and titanium at a 3-mm thickness. All 3 ceramic specimens in each thickness were placed in succession on different abutment backgrounds with glycerin optical fluid in between, and the color was measured. A digital spectrophotometer was used to record the specimen color value in the Commission Internationale De L'éclairage (CIELab) color coordinates system and to calculate the color difference (ΔE) between the control and experimental groups. The Kruskal-Wallis test was used to analyze the effect of ceramic thickness on different abutments, and the pair-wise test was used to evaluate within the group (α=.05). The color differences between the test groups and the control decreased with increasing ceramic thickness for every background material. In every case, significant differences were found between 1.0- and 2.5-mm ceramic thicknesses. Only certain 2.5-mm e.max CAD, VITA Suprinity PC, and Empress CAD specimens on yellow-shade zirconia or VITA Suprinity PC on titanium were identified as clinically acceptable (ΔE<3). Increasing ceramic restoration thickness over the abutment background decreased the color mismatch. Increasing the thickness of ceramic on a yellow-shaded zirconia abutment

  14. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.

    PubMed

    Quek, H C; Tan, Keson B; Nicholls, Jack I

    2008-01-01

    Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level

  15. Histological evaluations and inflammatory responses of different dental implant abutment materials: A human histology pilot study.

    PubMed

    Sampatanukul, Teeratida; Serichetaphongse, Pravej; Pimkhaokham, Atiphan

    2018-04-01

    Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials. To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, and gold alloy, over an 8-week healing period. Fifteen edentulous sites were treated with implants. Eight weeks later, peri-implant tissue was harvested and processed using a nonseparation resin embedded technique. The tissue attachment characteristics were assessed at clinical stages using the gingival index (GI) score, surgical stage (surgical score), and histological stage (histological attachment percentage). Additionally, the inflammatory responses were evaluated using inflammatory extent and inflammatory cellularity grades. Nonparametrical statistics were used to describe the GI and surgical scores, and analytical statistics were used to analyze the histological attachment percentages as well as the inflammatory extent and cellularity grades amongst the 3 groups. There were no statistically significant differences among the groups for GI score (P = .071) and surgical score (P = .262). Titanium and zirconia exhibited nearly similar mean histological attachment percentages while gold alloy had a significantly lower percentage (P = .004). For the inflammatory extent and cellularity grades, the odds of being one grade higher for gold alloy abutment was 5.18 and 17.8 times that of titanium abutment, respectively. However, for the zirconia abutment, the odds were 0.87 and 7.5 times higher than the titanium group. The tissue around the gold alloy abutments resulted in worse attachment conditions compared with the titanium and zirconia abutments. Inflammation tended to be higher in the tissue around the gold alloy abutments than the titanium and zirconia abutments. © 2017 Wiley Periodicals, Inc.

  16. Hydraulic Performance of Shallow Foundations for the Support of Vertical-Wall Bridge Abutments

    DOT National Transportation Integrated Search

    2017-02-01

    This study combined abutment flume experiments with numerical modeling using computational fluid dynamics (CFD) to investigate flow fields and scour at vertical-wall abutments with shallow foundations. The focus was situations dominated by flow contr...

  17. Determining the effectiveness of various treatment modalities in carpal tunnel syndrome by ultrasonography and comparing ultrasonographic findings with other outcomes.

    PubMed

    Soyupek, Feray; Yesildag, Ahmet; Kutluhan, Suleyman; Askin, Ayhan; Ozden, Ahmet; Uslusoy, Gokcen Ay; Demirci, Seden

    2012-10-01

    Firstly, we aimed to determine the effectiveness of various treatment modalities using ultrasonography (US), and secondly, we aimed to assess the correlations between the ultrasonographic findings and electrophysiological tests, symptom severity, functional status and physical findings. 74 hands of 47 patients with carpal tunnel syndrome (CTS) were randomly treated by applying wrist splinting alone in the neutral position (23 hands), phonophoresis with corticosteroid (PCS) (28 hands) and phonophoresis with non-steroid anti-inflamatory drug (PNSAI) (23 hands). The cross-sectional area (CSA) of the median nerve (MN) was determined by ultrasound on the initial and at the 3 months after treatment. MN conduction studies were performed on the initial visit and 3 months after treatment. The patients completed the Boston symptom severity questionnaire. For clinical evaluation, we used Phalen's and Tinel's signs. We could find reduction in CSA of MN in PCS group (P < 0.001). The CSA of MN was inversely correlated with motor sensory and median nerve conduction velocity (NCV) (r = 0.421, r = 0.213, respectively). Statistically significant correlations were not detected between ultrasonographic parameters and clinical evaluation parameters (P > 0.05) and also between ultrasonographic parameters and BQ scores (P > 0.05). Although there was some improvement in clinical parameters, ultrasonographic parameters did not change in P-NSAI group. The most effective treatment modality was P-CS according to ultrasonographic and other findings. Although there were inverse correlations between the CSA of MN and sensory and motor MN conduction velocity, no relationship was found between symptom severity, functional status and US findings or electrophysiological studies.

  18. Incidence rates of in-hospital carpal tunnel syndrome in the general population and possible associations with marital status.

    PubMed

    Mattioli, Stefano; Baldasseroni, Alberto; Curti, Stefania; Cooke, Robin M T; Bena, Antonella; de Giacomi, Giovanna; dell'Omo, Marco; Fateh-Moghadam, Pirous; Melani, Carla; Biocca, Marco; Buiatti, Eva; Campo, Giuseppe; Zanardi, Francesca; Violante, Francesco S

    2008-10-28

    Carpal tunnel syndrome (CTS) is a socially relevant condition associated with biomechanical risk factors. We evaluated age-sex-specific incidence rates of in-hospital cases of CTS in central/northern Italy and explored relations with marital status. Seven regions were considered (overall population, 14.9 million) over 3-6-year periods between 1997 and 2002 (when out-of-hospital CTS surgery was extremely rare). Incidence rates of in-hospital cases of CTS were estimated based on 1) codified demographic, diagnostic and intervention data in obligatory discharge records from all Italian public/private hospitals, archived (according to residence) on regional databases; 2) demographic general population data for each region. We compared (using the chiscore test) age-sex-specific rates between married, unmarried, divorced and widowed subsets of the general population. We calculated standardized incidence ratios (SIRs) for married/unmarried men and women. Age-standardized incidence rates (per 100,000 person-years) of in-hospital cases of CTS were 166 in women and 44 in men (106 overall). Married subjects of both sexes showed higher age-specific rates with respect to unmarried men/women. SIRs were calculated comparing married vs unmarried rates of both sexes: 1.59 (95% confidence interval [95% CI], 1.57-1.60) in women, and 1.42 (95% CI, 1.40-1.45) in men. As compared with married women/men, widows/widowers both showed 2-3-fold higher incidence peaks during the fourth decade of life (beyond 50 years of age, widowed subjects showed similar trends to unmarried counterparts). This large population-based study illustrates distinct age-related trends in men and women, and also raises the question whether marital status could be associated with CTS in the general population.

  19. Biomechanical and psychosocial exposures are independent risk factors for carpal tunnel syndrome: assessment of confounding using causal diagrams.

    PubMed

    Harris-Adamson, Carisa; Eisen, Ellen A; Neophytou, Andreas; Kapellusch, Jay; Garg, Arun; Hegmann, Kurt T; Thiese, Matthew S; Dale, Ann Marie; Evanoff, Bradley; Bao, Stephen; Silverstein, Barbara; Gerr, Fred; Burt, Susan; Rempel, David

    2016-11-01

    Between 2001 and 2010, six research groups conducted coordinated prospective studies of carpal tunnel syndrome (CTS) incidence among US workers from various industries to estimate exposure-response relationships. This analysis examined the presence and magnitude of confounding between biomechanical and workplace psychosocial factors and incidence of dominant-hand CTS. 1605 participants, without CTS at enrolment, were followed for up to 3.5 years (2471 person-years). Demographic information, medical history and workplace psychosocial stress measures were collected at baseline. Individual workplace biomechanical exposures were collected for each task and combined across the workweek using time-weighted averaging (TWA). CTS case criteria were based on symptoms and results of electrophysiological testing. HRs were estimated with Cox proportional hazard models. Confounding was assessed using causal diagrams and an empirical criterion of 10% or greater change in effect estimate magnitude. There were 109 incident CTS cases (IR=4.41/100 person-years; 6.7% cumulative incidence). The relationships between CTS and forceful repetition rate, % time forceful hand exertion and the Threshold Limit Value for Hand Activity Level (TLV-HAL) were slightly confounded by decision latitude with effect estimates being attenuated towards the null (10-14% change) after adjustment. The risk of CTS among participants reporting high job strain was attenuated towards the null by 14% after adjusting for the HAL Scale or the % time forceful hand exertions. Although attenuation of the relationships between CTS and some biomechanical and work psychosocial exposures was observed after adjusting for confounding, the magnitudes were small and confirmed biomechanical and work psychosocial exposures as independent risk factors for incident CTS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Three-dimensional modeling and animation of two carpal bones: a technique.

    PubMed

    Green, Jason K; Werner, Frederick W; Wang, Haoyu; Weiner, Marsha M; Sacks, Jonathan M; Short, Walter H

    2004-05-01

    The objectives of this study were to (a). create 3D reconstructions of two carpal bones from single CT data sets and animate these bones with experimental in vitro motion data collected during dynamic loading of the wrist joint, (b). develop a technique to calculate the minimum interbone distance between the two carpal bones, and (c). validate the interbone distance calculation process. This method utilized commercial software to create the animations and an in-house program to interface with three-dimensional CAD software to calculate the minimum distance between the irregular geometries of the bones. This interbone minimum distance provides quantitative information regarding the motion of the bones studied and may help to understand and quantify the effects of ligamentous injury.

  1. Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.

    PubMed

    Ecker, J; Perera, N; Ebert, J

    2015-02-01

    Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.

  2. Individual risk factors for carpal tunnel syndrome: an evaluation of body mass index, wrist index and hand anthropometric measurements.

    PubMed

    Boz, Cavit; Ozmenoglu, Mehmet; Altunayoglu, Vildan; Velioglu, Sibel; Alioglu, Zekeriya

    2004-09-01

    In this study we aimed to identify the role of the body mass index (BMI), wrist index and hand anthropometric measures as risk factors for carpal tunnel syndrome (CTS) in both genders. Based on clinical and electrophysiologic diagnostic criteria, 154 female and 44 male CTS patients, as well as 150 female and 44 male age-matched control subjects, were selected. BMI, wrist index, hand shape index, digit index and hand length/height ratio were compared between the CTS patients and the control subjects for each gender separately. Mean BMI was found to be a significant risk factor for CTS in both genders. The wrist index was found to be higher in female (P < 0.001) and in male (P = 0.034) CTS groups than in the respective control groups. Logistic regression analysis revealed the wrist index to be an independent risk factor in females, but not in males. Shape and digit indices were significantly higher in female CTS patients than in corresponding control subjects, and regression analysis showed the shape and digit indices to be independent risk factors for CTS. In the male CTS group, the shape and digit indices did not significantly differ from their controls. Differences in the hand length/height ratio were not statistically significant in female and male CTS patients compared to their controls and it was not found to be an independent risk factor for CTS. Our study confirmed BMI as an independent risk factor for CTS in both genders. Hand and wrist anthropometrics were found to be independent risk factors for CTS in females, but not in males.

  3. The role of job strain on return to work after carpal tunnel surgery

    PubMed Central

    Gimeno, D; Amick, B; Habeck, R; Ossmann, J; Katz, J

    2005-01-01

    Aims: To examine the impact of job strain (that is, high psychological job demands and low job control) on return to work and work role functioning at two months, six months, or both, following carpal tunnel release surgery. Methods: A community based cohort of carpal tunnel syndrome (CTS) patients from physician practices was recruited between April 1997 and October 1998 throughout Maine (USA). 128 patients at two months and 122 at six months completed all relevant questions. A three level outcome variable indicated whether patients had: (1) returned to work functioning successfully, (2) returned to work functioning with limitations, or (3) not returned to work for health reasons. Two job strain measures were created: one, by combining psychological job demands and job control; and two, by dividing demands by control. Ordinal logistic regression was used to identify predictors of the three level work outcome variable. Results: After adjustment, workers with high demands and high control (active work) were less likely to successfully return to work (OR = 0.22; p = 0.014) at two months. Having a job with higher demands than job control (high strain) predicted not returning to work or returning to work but not successfully meeting job demands (OR = 0.14; p = 0.001), at six months. Conclusions: The findings underscore the role of psychosocial work conditions, as defined by the Karasek demand-control model, in explaining a worker's return to work. Clinicians, researchers, and employers should consider a multidimensional and integrative model of successful work role functioning upon return to work. Moreover, since the evidence of the effects of work process changes on the reduction of CTS is very scarce, these findings point to the opportunity for collaborative workplace interventions to facilitate successful return to work. PMID:16234404

  4. The total occlusal convergence of the abutment of a partial fixed dental prosthesis: A definition and a clinical technique for its assessment

    PubMed Central

    Mamoun, John S.

    2013-01-01

    The abutment(s) of a partial fixed dental prosthesis (PFDP) should have a minimal total occlusal convergence (TOC), also called a taper, in order to ensure adequate retention of a PFDP that will be made for the abutment(s), given the height of the abutment(s). This article reviews the concept of PFDP abutment TOC and presents an alternative definition of what TOC is, defining it as the extent to which the shape of an abutment differs from an ideal cylinder shape of an abutment. This article also reviews experimental results concerning what is the ideal TOC in degrees and explores clinical techniques of estimating the TOC of a crown abutment. The author suggests that Dentists use high magnification loupes (×6-8 magnification or greater) or a surgical operating microscope when preparing crown abutments, to facilitate creating a minimum abutment TOC. PMID:24932130

  5. Long-term behavior of integral abutment bridges : appendix E, INDOT design manual : selected recommendations for integral abutment bridges.

    DOT National Transportation Integrated Search

    2011-01-01

    Integral abutment (IA) construction has become the preferred method over conventional construction for use with typical highway bridges. However, the use of these structures is limited due to state mandated length and skew limitations. To expand thei...

  6. Assessment of the NCHRP abutment scour prediction equations with laboratory and field data

    USGS Publications Warehouse

    Benedict, Stephen T.

    2014-01-01

    The U.S. Geological Survey, in coopeation with nthe National Cooperative Highway Research Program (NCHRP) is assessing the performance of several abutment-scour predcition equations developed in NCHRP Project 24-15(2) and NCHRP Project 24-20. To accomplish this assssment, 516 laboratory and 329 fiels measurements of abutment scor were complied from selected sources and applied tto the new equations. Results will be used to identify stregths, weaknesses, and limitations of the NCHRP abutment scour equations, providing practical insights for applying the equations. This paper presents some prelimiray findings from the investigation.

  7. Case report. Pediatric carpal fracture dislocation.

    PubMed

    DeCoster, T A; Faherty, S; Morris, A L

    1994-01-01

    Transcarpal fractures in children are rare in the orthopaedic literature. This is a case report of a 10-year-old boy who sustained fractures across the distal radius, scaphoid, lunate, and triquetrum with gross displacement. Treatment consisted of open reduction with internal fixation of the fractures and ligamentous repair through a combined dorsal and palmar approach. The injury healed with good wrist function but abnormal carpal development. This unusual pattern of injury is described so that it may be more readily appreciated in the future.

  8. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment.

    PubMed

    Glisić, Mirko; Stamenković, Dragoslav; Grbović, Aleksandar; Todorović, Aleksandar; Marković, Aleksa; Trifković, Branka

    2016-01-01

    Differences between the tooth and implant response to load can lead to many biological and technical implications in the conditions of occlusal forces. The objective of this study was to analyze load distribution in tooth/implant-supported fixed partial dentures with the use of resilient TSA (Titan Shock Absorber, BoneCare GmbH, Augsburg, Germany) abutment and conventional non-resilient abutment using finite element method. This study presents two basic 3D models. For one model a standard non-resilient abutment is used, and on the implant of the second model a resilient TSA abutment is applied. The virtual model contains drawn contours of tooth, mucous membranes, implant, cortical bones and spongiosa, abutment and suprastructure. The experiment used 500 N of vertical force, applied in three different cases of axial load. Calculations of von Mises equivalent stresses of the tooth root and periodontium, implants and peri-implant tissue were made. For the model to which a non-resilient abutment is applied, maximum stress values in all three cases are observed in the cortical part of the bone (maximum stress value of 49.7 MPa). Measurements of stress and deformation in the bone tissue in the model with application of the resilientTSA abutment demonstrated similar distribution; however, these values are many times lower than in the model with non-resilient TSA abutment (maximum stress value of 28.9 MPa). Application of the resilient TSA abutment results in more equal distribution of stress and deformations in the bone tissue under vertical forces. These values are many times lower than in the model with the non-resilient abutment.

  9. Soft tissues stability of cad-cam and stock abutments in anterior regions: 2-year prospective multicentric cohort study.

    PubMed

    Lops, Diego; Bressan, Eriberto; Parpaiola, Andrea; Sbricoli, Luca; Cecchinato, Denis; Romeo, Eugenio

    2015-12-01

    Aim of this study was to verify if the type of implant abutment manufacturing, stock or cad-cam, could influence the maintenance of stable gingival margins around single restorations in anterior areas. After 16 weeks of healing, implants (Osseospeed, Astra Tech Dental Implant) were positioned. Depending on the different fixture inclination and the thickness of buccal peri-implant soft tissue, abutment selection resulted in four groups: Group 1 (patients with zirconia ZirDesign(®) stock abutments), Group 2 (titanium stock TiDesign(®) abutments), Group 3 (zirconia cad-cam abutments), and Group 4 (titanium cad-cam abutments). The following parameters were assessed: buccal gingival margin modification (BGM). The modification of the implant gingival margin was followed at 1 and 2 years of follow-up. A computerized analysis was performed for measurements. Differences between soft tissue margin at baseline and after 2 years measured the gingival margin recession. A general linear model was used to evaluate each group in relation to gingival recession after two years. Tukey's post hoc test was used to compare the mean REC indexes of each group of abutments. Seventy-two healthy patients (39 males and 33 females; mean age of 46 years) scheduled for single gap rehabilitation in anterior areas were enrolled. A 100% of implant survival rate was observed after 24 months of function. One failure occurred due to fracture of a Zirconia cad-cam abutment. Moreover, two abutment screw unscrewing were observed. Both for zirconia and titanium stock abutments (Group 1 and 2), the mean recession of implant buccal soft tissue was of 0.3 mm (SD of 0.3 and 0.4 mm, respectively). Soft tissue mean recession of zirconia and titanium cad-cam abutments (Group 3 and 4) was of 0.1 and -0.3 mm, respectively (SD of 0.3 and 0.4 mm, respectively). REC values of cad-cam titanium abutments (Group 4) were significantly lower than that of Group 1 (-0.57 mm), Group 2 (-0.61 mm), and Group 3 (-0.40 mm

  10. WRIST: A WRist Image Segmentation Toolkit for carpal bone delineation from MRI.

    PubMed

    Foster, Brent; Joshi, Anand A; Borgese, Marissa; Abdelhafez, Yasser; Boutin, Robert D; Chaudhari, Abhijit J

    2018-01-01

    Segmentation of the carpal bones from 3D imaging modalities, such as magnetic resonance imaging (MRI), is commonly performed for in vivo analysis of wrist morphology, kinematics, and biomechanics. This crucial task is typically carried out manually and is labor intensive, time consuming, subject to high inter- and intra-observer variability, and may result in topologically incorrect surfaces. We present a method, WRist Image Segmentation Toolkit (WRIST), for 3D semi-automated, rapid segmentation of the carpal bones of the wrist from MRI. In our method, the boundary of the bones were iteratively found using prior known anatomical constraints and a shape-detection level set. The parameters of the method were optimized using a training dataset of 48 manually segmented carpal bones and evaluated on 112 carpal bones which included both healthy participants without known wrist conditions and participants with thumb basilar osteoarthritis (OA). Manual segmentation by two expert human observers was considered as a reference. On the healthy subject dataset we obtained a Dice overlap of 93.0 ± 3.8, Jaccard Index of 87.3 ± 6.2, and a Hausdorff distance of 2.7 ± 3.4 mm, while on the OA dataset we obtained a Dice overlap of 90.7 ± 8.6, Jaccard Index of 83.0 ± 10.6, and a Hausdorff distance of 4.0 ± 4.4 mm. The short computational time of 20.8 s per bone (or 5.1 s per bone in the parallelized version) and the high agreement with the expert observers gives WRIST the potential to be utilized in musculoskeletal research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Evaluation of concordance between CAD/CAM and clinical positions of abutment shoulder against mucosal margin: an observational study.

    PubMed

    Pietruski, Jan K; Skurska, Anna; Bernaczyk, Anna; Milewski, Robert; Pietruska, Maria Julia; Gehrke, Peter; Pietruska, Małgorzata D

    2018-05-02

    While working on CAD/CAM-customized abutments, the use of standard impression copings with a circular diameter produces inconsistency within the emergence profile. It may begin with a collapse of the supra-implant mucosa during impression taking, then lead to a computer-generated mismatch of the position and outline of the abutment shoulder, and consequently result in a compromised outcome of anticipated treatment. The aim of the study was to compare the virtual and clinical positions of the abutment shoulder in relation to the mucosal margin after the abutment delivery. Conventional open-tray impression takings followed uncovering surgery. Master casts were scanned with a desktop scanner. Clinical examinations took place after abutment's insertion and temporization (T1) and prior to cementation of the definitive crown (T2). The distances between the abutment shoulder and marginal soft tissue were measured intraorally in four aspects and juxtaposed with those on the virtual model. The study evaluated 257 dental implants and CAD/CAM-customized abutments. As T1 and T2 showed, there was a positive correlation between the virtually designed abutment shoulder position and matching clinical location relative to the mucosal margin. In 42.1% of cases, the distance between the mucosal margin and the abutment shoulder did not change. It increased in 36.3% of cases while a decrease occurred in 21.6% of them. Computer-set position of the abutment shoulder in relation to the mucosal margin can be predictably implemented in clinical practice.

  12. The Evaluation of Unscrewing Torque Values of Implant-Abutment Connections: An In Vitro Study.

    PubMed

    Bruna, Ezio; Fabianelli, Andrea; Mastriforti, Giacomo; Papacchini, Federica

    This study investigated the stability of titanium screws in implant-abutment connections by measuring the force necessary to induce unscrewing. A total of 60 implant-abutment couplings were assigned to two groups (n = 30 each). The sequence 10-20-32 Ncm was tested in Group 1; the sequence 10-20-32-32-32 Ncm was tested in Group 2. The force necessary to unscrew each abutment-implant sample was recorded and statistically analyzed. The significance level was set at P < .05. Significant differences were found between the two sequences. Group 2 required higher forces than Group 1 to unscrew. The stability of the implant-abutment joint may be improved by tightening with the sequence 10-20-32-32-32 Ncm.

  13. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.

    PubMed

    Xia, Dandan; Lin, Hong; Yuan, Shenpo; Bai, Wei; Zheng, Gang

    2014-01-01

    Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each group were unscrewed, and their reverse torque values recorded. The remaining specimens were subjected to a load between 30 N~300 N at a loading frequency of 15 Hz for 5 × 10(6) cycles. After fatigue tests, residual reverse torque values were recorded if available. In the 24 Ncm tightening group, all the implants fractured at the first outer thread of the implant after fatigue loading, with fatigue crack propagation at the fractured surface showed by SEM observation. For the 30 Ncm and 36 Ncm tightening groups, a statistical significant difference (p<0.05) between the unloaded and loaded groups was revealed. Compared with the unloaded specimens, the specimens went through fatigue loading had decreased reverse torque values. It was demonstrated that insufficient torque will lead to poor fatigue performance of dental implant-abutment assemblies and abutment screws should be tightened to the torque recommended by the manufacturer. It was also concluded that fatigue loading would lead to preload loss.

  14. Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections.

    PubMed

    Siadat, Hakimeh; Beyabanaki, Elaheh; Mousavi, Niloufar; Alikhasi, Marzieh

    2017-08-01

    This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. Two regular platform dental implants, one with external connection (Brånemark, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at α=0.05 of significance. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups ( P <.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom ( P <.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments ( P <.001). However, neither connection type ( P =.15) nor abutment material ( P =.38) affected torque loss. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

  15. A Simplified Technique for Implant-Abutment Level Impression after Soft Tissue Adaptation around Provisional Restoration

    PubMed Central

    Kutkut, Ahmad; Abu-Hammad, Osama; Frazer, Robert

    2016-01-01

    Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations. PMID:29563457

  16. An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants.

    PubMed

    Park, Ji-Man; Baek, Chang-Hyun; Heo, Seong-Joo; Kim, Seong-Kyun; Koak, Jai-Young; Kim, Shin-Koo; Belser, Urs C

    The aim of this study was to compare the loosening of interchangeable one-piece abutments connected to internal-connection-type implants after cyclic loading. Four implant abutment groups (n = 7 in each group) with Straumann tissue-level implants were assessed: Straumann solid abutment (group S), Southern Implants solid abutment (group SI), Implant Direct straight abutment (group ID), and Blue Sky Bio regular platform abutment (group BSB). The implant was firmly held in a special jig to ensure fixation. Abutment screws were tightened to manufacturers' recommended torque with a digital torque gauge. The hemispherical loading members were fabricated for the load cell of a universal testing machine to evenly distribute the force on the specimens and to fulfill the ISO 14801:2007 standard. A cyclic loading of 25 N at 30 degrees to the implant's long axis was applied for a duty of a half million cycles. Tightening torques were measured prior to the loading. Removal torques were measured after cyclic loading. The data were analyzed with one-way analysis of variance (ANOVA), and the significance level was set at P < .05. The mean removal torques after cyclic loading were 34.0 ± 1.1 Ncm (group S), 25.0 ± 1.5 Ncm (group SI), 23.9 ± 2.1 Ncm (group ID), and 27.9 ± 1.3 Ncm (group BSB). Removal torques of each group were statistically different in the order of group S > group BSB > groups SI and ID (P < .05). The mean reduction rates were -2.9% ± 3.2% (group S), -21.9% ± 4.8% (group SI), -20.2% ± 7.2% (group ID), and -6.9% ± 4.3% (group BSB) after a half million cycles, respectively. Reduction rates of groups S and BSB were statistically lower than those of groups SI and ID (P < .01). The standard deviation of group S was lower than group BSB. The removal torque of the original Straumann abutment was significantly higher than those of the copy abutments. The reduction rate of the groups S and BSB abutments was lower than those of the other copy abutments.

  17. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    PubMed

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (P<0.05). In 4.0 mm-diameter abutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (P<0.05). The FEA results showed that stress values varied in implants with different abutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Carpal spasm in a girl as initial presentation of celiac disease: a case report.

    PubMed

    Ramosaj-Morina, Atifete; Keka-Sylaj, A; Hasbahta, V; Baloku-Zejnullahu, A; Azemi, M; Zunec, R

    2017-09-04

    Celiac disease is an immune-mediated disorder elicited by ingestion of gluten in genetically susceptible persons. This disorder is characterized by specific histological changes of the small intestine mucosa resulting in malabsorption. This case was written up as it was an unusual and dramatic presentation of celiac disease. We report the case of a 3-year-old Albanian girl who presented at our clinic with carpal spasms and hand paresthesia. A physical examination at admission revealed a relatively good general condition and body weight of 10.5 kg (10 percentile). Carpal spasms and paresthesias of her extremities were present. Neuromuscular irritability was demonstrated by positive Chvostek and Trousseau signs. Blood tests showed severe hypocalcemia with a total serum calcium of 1.2 mmol/L (normal range 2.12 to 2.55 mmol/L), ionized calcium of 0.87 (normal range 1.11 to 1.30 mmol/L), and 24-hour urine calcium excretion of 9.16 mmol (normal range female <6.2 mmol/day). Among other tests, screening for celiac disease was performed: antigliadin immunoglobulin A, anti-tissue transglutaminase, and anti-endomysial immunoglobulin A antibodies were positive. A duodenal biopsy revealed lymphocyte infiltration, crypt hyperplasia, and villous atrophy compatible with celiac disease grade IIIb according to the Marsh classification. Following the diagnosis of celiac disease, human leukocyte antigen typing was performed, giving a definite diagnosis of celiac disease. She was started on a gluten-free diet. Due to failure to follow a gluten-free diet, episodes of carpal spasms appeared again. Unfortunately, at the age of 7 years she presents with delayed psychophysical development. Although hypocalcemia is a common finding in celiac disease, hypocalcemic carpal spasm is a rare initial manifestation of the disease. Therefore, the possibility of celiac disease should be considered in patients with repeated carpal spasms that seem unduly difficult to treat. This should be

  19. Comparison of The Effect of Implant Abutment Surface Modifications on Retention of Implant-Supported Restoration with A Polymer Based Cement

    PubMed Central

    Sahu, Nabaprakash; Lakshmi, Namratha; Azhagarasan, N.S.; Agnihotri, Yoshaskam; Rajan, Manoj; Hariharan, Ramasubramanian

    2014-01-01

    Background: In cement-retained implant-supported restoration it is important to gain adequate retention of definitive restoration as well as retrievability of prosthesis. The surface of the abutment, alloy of the restoration and the type of cement used influences the retention of the restoration. There is a need to analyze the influence of surface modifications of abutments on the retentive capabilities of provisional implant cements. Purpose of study: To compare the effect of implant abutment surface modifications on retention of implant-supported restoration cemented with polymer based cement. Materials and method: Thirty solid titanium implant abutments (ADIN), 8mm height, were divided into 3 groups. Ten abutments with retentive grooves (Group I) as supplied by the manufacturer, Ten abutments milled to 20 taper circumferentially (Group II), and Ten abutments milled and air-abraded with 110 μm aluminum oxide (Group III) were used in this study. Ni-Cr coping were casted for each abutment and polymer based cement was used to secure them to the respective abutments. Using a universal testing machine at a crosshead speed of 0.5 cm/minute, tensile bond strength was recorded (N). Results: Mean tensile bond strength of Group I, II and III were found to be 408.3, 159.9 and 743.8 Newton respectively. The values were statistically different from each other (p<0.001). Conclusion: Abutments with milled and sandblasted surface provide the highest retention followed by abutments with retentive grooves and then by abutments with milled surface when cast copings were cemented to implant abutments with polymer based cement. Clinical implications: Retention of restoration depends on the surface of the abutment as well as the luting agents used. Incorporation of retentive grooves or particle abrasion can enhance retention especially in situation of short clinical crown. PMID:24596785

  20. A prospective, split-mouth study comparing tilted implants with angulated connection versus conventional implants with angulated abutment.

    PubMed

    Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan

    2017-12-01

    An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P < .001). There was no significant difference in MBL between the implants restored with zirconia or PFM bridges (P = .294). Overall mean pocket depth was 2.83 mm. More plaque was found in the PFM group compared to the full-zirconia group, at the bridge (P = .042) and the implants (P = .029). There was no difference between both materials in pocket depth (P = .635) or bleeding (P = .821). One zirconia bridge fractured, two angulated abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce