Geographic applications of ERTS-1 data to landscape change
NASA Technical Reports Server (NTRS)
Rehder, J. B.
1973-01-01
The analysis of landscape change requires large area coverage on a periodic basis in order to analyze aggregate changes over an extended period of time. To date, only the ERTS program can provide this capability. Three avenues of experimentation and analysis are being used in the investigation: (1) a multi-scale sampling procedure utilizing aircraft imagery for ground truth and control; (2) a densitometric and computer analytical experiment for the analysis of gray tone signatures, comparisons and ultimately for landscape change detection and monitoring; and (3) an ERTS image enhancement procedure for the detection and analysis of photomorphic regions.
Ballastic signature identification systems study
NASA Technical Reports Server (NTRS)
Reich, A.; Hine, T. L.
1976-01-01
The results are described of an attempt to establish a uniform procedure for documenting (recording) expended bullet signatures as effortlessly as possible and to build a comprehensive library of these signatures in a form that will permit the automated comparison of a new suspect bullet with the prestored library. The ultimate objective is to achieve a standardized format that will permit nationwide interaction between police departments, crime laboratories, and other interested law enforcement agencies.
Bereman, Michael S.; Egertson, Jarrett D.; MacCoss, Michael J.
2012-01-01
Filter aided sample preparation (FASP) and a new sample preparation method using a modified commercial SDS removal spin column are quantitatively compared in terms of their performance for shotgun proteomic experiments in three complex proteomic samples: a Saccharomyces cerevisiae lysate (insoluble fraction), a Caenorhabditis elegans lysate (soluble fraction), and a human embryonic kidney cell line (HEK293T). The characteristics and total number of peptides and proteins identified are compared between the two procedures. The SDS spin column procedure affords a conservative 4-fold improvement in throughput, is more reproducible, less expensive (i.e., requires less materials), and identifies between 30–107% more peptides at a q≤0.01, than the FASP procedure. The peptides identified by SDS spin column are more hydrophobic than species identified by the FASP procedure as indicated by the distribution of GRAVY scores. Ultimately, these improvements correlate to as great as a 50% increase in protein identifications with 2 or more peptides. PMID:21656683
NASA Technical Reports Server (NTRS)
Bareiss, L. E.
1978-01-01
The paper presents a compilation of the results of a systems level Shuttle/payload contamination analysis and related computer modeling activities. The current technical assessment of the contamination problems anticipated during the Spacelab program are discussed and recommendations are presented on contamination abatement designs and operational procedures based on experience gained in the field of contamination analysis and assessment, dating back to the pre-Skylab era. The ultimate test of the Shuttle/Payload Contamination Evaluation program will be through comparison of predictions with measured levels of contamination during actual flight.
Bao, Yihai; Main, Joseph A; Noh, Sam-Young
2017-08-01
A computational methodology is presented for evaluating structural robustness against column loss. The methodology is illustrated through application to reinforced concrete (RC) frame buildings, using a reduced-order modeling approach for three-dimensional RC framing systems that includes the floor slabs. Comparisons with high-fidelity finite-element model results are presented to verify the approach. Pushdown analyses of prototype buildings under column loss scenarios are performed using the reduced-order modeling approach, and an energy-based procedure is employed to account for the dynamic effects associated with sudden column loss. Results obtained using the energy-based approach are found to be in good agreement with results from direct dynamic analysis of sudden column loss. A metric for structural robustness is proposed, calculated by normalizing the ultimate capacities of the structural system under sudden column loss by the applicable service-level gravity loading and by evaluating the minimum value of this normalized ultimate capacity over all column removal scenarios. The procedure is applied to two prototype 10-story RC buildings, one employing intermediate moment frames (IMFs) and the other employing special moment frames (SMFs). The SMF building, with its more stringent seismic design and detailing, is found to have greater robustness.
Aircraft noise effects on cultural resources: Recommendation and rationale for further research
NASA Astrophysics Data System (ADS)
Hanson, Carl E.; King, Kenneth W.; Eagan, Mary Ellen; Horonjeff, Richard D.
1993-05-01
The results are ultimately used to estimate the potential for damage to a wide variety of cultural resources from operations of commercial helicopters. Comparison of measured vibration levels with criteria for damage based on structural velocities will provide a family of restrictions on aircraft operations in the vicinity of sensitive structures. Such restrictions could take the form of minimum separation distances and prohibited maneuvers for helicopters. The results of the study would be presented in a report as a set of recommended procedures for helicopter operations to avoid damage to prehistoric, historic, sensitive, and conventional structures.
Bao, Yihai; Main, Joseph A.; Noh, Sam-Young
2017-01-01
A computational methodology is presented for evaluating structural robustness against column loss. The methodology is illustrated through application to reinforced concrete (RC) frame buildings, using a reduced-order modeling approach for three-dimensional RC framing systems that includes the floor slabs. Comparisons with high-fidelity finite-element model results are presented to verify the approach. Pushdown analyses of prototype buildings under column loss scenarios are performed using the reduced-order modeling approach, and an energy-based procedure is employed to account for the dynamic effects associated with sudden column loss. Results obtained using the energy-based approach are found to be in good agreement with results from direct dynamic analysis of sudden column loss. A metric for structural robustness is proposed, calculated by normalizing the ultimate capacities of the structural system under sudden column loss by the applicable service-level gravity loading and by evaluating the minimum value of this normalized ultimate capacity over all column removal scenarios. The procedure is applied to two prototype 10-story RC buildings, one employing intermediate moment frames (IMFs) and the other employing special moment frames (SMFs). The SMF building, with its more stringent seismic design and detailing, is found to have greater robustness. PMID:28890599
Williams, Mark R; McKeown, Andrew; Dexter, Franklin; Miner, James R; Sessler, Daniel I; Vargo, John; Turk, Dennis C; Dworkin, Robert H
2016-01-01
Successful procedural sedation represents a spectrum of patient- and clinician-related goals. The absence of a gold-standard measure of the efficacy of procedural sedation has led to a variety of outcomes being used in clinical trials, with the consequent lack of consistency among measures, making comparisons among trials and meta-analyses challenging. We evaluated which existing measures have undergone psychometric analysis in a procedural sedation setting and whether the validity of any of these measures support their use across the range of procedures for which sedation is indicated. Numerous measures were found to have been used in clinical research on procedural sedation across a wide range of procedures. However, reliability and validity have been evaluated for only a limited number of sedation scales, observer-rated pain/discomfort scales, and satisfaction measures in only a few categories of procedures. Typically, studies only examined 1 or 2 aspects of scale validity. The results are likely unique to the specific clinical settings they were tested in. Certain scales, for example, those requiring motor stimulation, are unsuitable to evaluate sedation for procedures where movement is prohibited (e.g., magnetic resonance imaging scans). Further work is required to evaluate existing measures for procedures for which they were not developed. Depending on the outcomes of these efforts, it might ultimately be necessary to consider measures of sedation efficacy to be procedure specific.
The economics of surgical laser technology in veterinary practice.
Irwin, James R
2002-05-01
A decision to invest in and develop laser technology should only be made after a thorough investigation and comparison of the available types, vendors, available features, and purchasing options. A sound marketing program must then be used for introducing laser technology to the staff, clients, and colleagues. Without adhering to such a program, a practice will [figure: see text] not experience the necessary profitability following the purchase of a laser. Staff enthusiasm and support will dwindle, and ultimately the laser investment will be viewed unfavorably. When marketed properly, however, the investment in a surgical laser will provide outstanding profitability. The return on investment can be provided by using the support staff for client education, by offering laser technology for routine elective procedures and complex procedures, and by adhering strictly to a fee schedule. Add that to the truly remarkable results obtained using laser surgical techniques, a practice will be greatly enhanced.
NASA Astrophysics Data System (ADS)
Durocher, M.; Mostofi Zadeh, S.; Burn, D. H.; Ashkar, F.
2017-12-01
Floods are one of the most costly hazards and frequency analysis of river discharges is an important part of the tools at our disposal to evaluate their inherent risks and to provide an adequate response. In comparison to the common examination of annual streamflow maximums, peaks over threshold (POT) is an interesting alternative that makes better use of the available information by including more than one flood event per year (on average). However, a major challenge is the selection of a satisfactory threshold above which peaks are assumed to respect certain conditions necessary for an adequate estimation of the risk. Additionally, studies have shown that POT is also a valuable approach to investigate the evolution of flood regimes in the context of climate change. Recently, automatic procedures for the selection of the threshold were suggested to guide that important choice, which otherwise rely on graphical tools and expert judgment. Furthermore, having an automatic procedure that is objective allows for quickly repeating the analysis on a large number of samples, which is useful in the context of large databases or for uncertainty analysis based on a resampling approach. This study investigates the impact of considering such procedures in a case study including many sites across Canada. A simulation study is conducted to evaluate the bias and predictive power of the automatic procedures in similar conditions as well as investigating the power of derived nonstationarity tests. The results obtained are also evaluated in the light of expert judgments established in a previous study. Ultimately, this study provides a thorough examination of the considerations that need to be addressed when conducting POT analysis using automatic threshold selection.
Image-guided tumor ablation: standardization of terminology and reporting criteria.
Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G
2005-06-01
The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency, laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. Copyright RSNA, 2005.
75 FR 69791 - Risk Management Controls for Brokers or Dealers With Market Access
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
... relationship with the ultimate customer, can more effectively implement them. In addition, a broker or dealer... specific risk management controls and supervisory procedures to a customer that is a registered broker... such customer, based on its position in the transaction and relationship with the ultimate customer...
Line fiducial material and thickness considerations for ultrasound calibration
NASA Astrophysics Data System (ADS)
Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.
2015-03-01
Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower echogenicity are more accurately segmented in comparison to highly reflective thin phantoms. This improvement in segmentation accuracy leads to a lower fiducial localization error, which ultimately results in low target registration error. This would have a profound effect on calibration procedures and the feasibility of different calibration procedures in the context of image-guided procedures.
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... considered acceptable for demonstration of IVD control performance. Examples of acceptable test procedures... carburetor deposits. Examples of acceptable test procedures for demonstration of carburetor deposit control... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold...
Flexural Behavior of HPFRCC Members with Inhomogeneous Material Properties.
Shin, Kyung-Joon; Jang, Kyu-Hyeon; Choi, Young-Cheol; Lee, Seong-Cheol
2015-04-21
In this paper, the flexural behavior of High-performance Fiber-Reinforced Cementitious Composite (HPFRCC) has been investigated, especially focusing on the localization of cracks, which significantly governs the flexural behavior of HPFRCC members. From four points bending tests with HPFRCC members, it was observed that almost evenly distributed cracks formed gradually, followed by a localized crack that determined the failure of the members. In order to investigate the effect of a localized crack on the flexural behavior of HPFRCC members, an analytical procedure has been developed with the consideration of intrinsic inhomogeneous material properties of HPFRCC such as cracking and ultimate tensile strengths. From the comparison, while the predictions with homogeneous material properties overestimated flexural strength and ductility of HPFRCC members, it was found that the analysis results considering localization effect with inhomogeneous material properties showed good agreement with the test results, not only the flexural strength and ductility but also the crack widths. The test results and the developed analysis procedure presented in this paper can be usefully applied for the prediction of flexural behaviors of HPFRCC members by considering the effect of localized cracking behavior.
NASA Astrophysics Data System (ADS)
Lindley, S. J.; Longhurst, J. W. S.; Watson, A. F. R.; Conlan, D. E.
This paper considers the value of applying an alternative pro rata methodology to the estimation of atmospheric emissions from a given regional or local area. Such investigations into less time and resource intensive means of providing estimates in comparison to traditional methods are important due to the potential role of new methods in the development of air quality management plans. A pro rata approach is used here to estimate emissions of SO 2, NO x, CO, CO 2, VOCs and black smoke from all sources and Pb from transportation for the North West region of England. This method has the advantage of using readily available data as well as being an easily repeatable procedure which provides a good indication of emissions to be expected from a particular geographical region. This can then provide the impetus for further emission studies and ultimately a regional/local air quality management plan. Results suggest that between 1987 and 1991 trends in the emissions of the pollutants considered have been less favourable in the North West region than in the nation as a whole.
Rettenmaier, N B; Rettenmaier, C R; Wojciechowski, T; Abaid, L N; Brown, J V; Micha, J P; Goldstein, B H
2010-11-23
The purpose of this study was to evaluate the number of ovarian cancer and primary peritoneal cancer (PPC) progressive disease cases identified via routine follow-up procedures and the corresponding cost throughout a 16-year period at a single medical institution. Previously undiagnosed epithelial ovarian (n=241), PPC (n=23), and concurrent ovarian and uterine (n=24) cancer patients were treated and then followed via CA-125, imaging (e.g., CT scan, chest X-ray), physical examination and vaginal cytology. In the group of 287 patients, there were 151 cases of disease progression. Serial imaging detected the highest number of progressive disease cases (66 initial and 45 confirmatory diagnoses), but the cost was rather high ($13,454 per patient recurrence), whereas CA-125 testing (74 initial and 20 corroborative diagnoses) was the least expensive ($3,924) per recurrent diagnosis. The total cost of surveillance during the 16-year period was nearly $2,400,000. Ultimately, serial imaging and the CA-125 assay detected the highest number of ovarian cancer and PCC progressive disease cases in comparison to physical examination and vaginal cytology, but nevertheless, all of the procedures were conducted at a considerable financial expense.
49 CFR 1017.5 - Hearing procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... OF TRANSPORTATION GENERAL RULES AND REGULATIONS DEBT COLLECTION-COLLECTION BY OFFSET FROM INDEBTED GOVERNMENT AND FORMER GOVERNMENT EMPLOYEES § 1017.5 Hearing procedures. (a) Upon the Administrative Law Judge... debt. (f) The employee requesting the hearing shall bear the ultimate burden of proof. (g) The evidence...
NASA Technical Reports Server (NTRS)
Predmore, Roamer; Woods, Claudia; Hovanec, Andrew
1997-01-01
In response to the elimination of production of several Ozone Depleting Chemicals (ODCs) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-Free cleaning procedures. One leg of that philosophy is the initiation of a several tier testing program which will deliver increasing amounts of information over the next few years, starting with original surface analysis comparisons between ODC and various ODC-Free cleaning technologies. The other leg is the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years with a number of important tribological questions unanswered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life mechanism based on a number of parameters, including a comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODCs based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.
Quality and performance indicators in an academic department of head and neck surgery.
Weber, Randal S; Lewis, Carol M; Eastman, Scott D; Hanna, Ehab Y; Akiwumi, Olubumi; Hessel, Amy C; Lai, Stephen Y; Kian, Leslie; Kupferman, Michael E; Roberts, Dianna B
2010-12-01
to create a method for assessing physician performance and care outcomes that are adjusted for procedure acuity and patient comorbidity. between 2004 and 2008 surgical procedures performed by 10 surgeons were stratified into high-acuity procedures (HAPs) and low-acuity procedures (LAPs). Risk adjustment was made for comorbid conditions examined singly or in groups of 2 or more. a tertiary care medical center. a total of 2618 surgical patients. performance measures included length of stay; return to operating room within 7 days of surgery; and the occurrence of mortality, hospital readmission, transfusion, and wound infection within 30 days of surgery. the transfusion rate was 2.7% and 40.6% for LAPs and HAPs, respectively. Wound infection rates were 1.4% for LAPs vs 14.1% for HAPs, while 30-day mortality rate was 0.3% and 1.6% for LAPs and HAPs, respectively. The mean (SD) hospital stay for LAPs was 2.1 (3.6) vs 10.5 (7.0) days for HAPs. Negative performance factors were significantly higher for patients who underwent HAPs and had comorbid conditions. Differences among surgeons significantly affect the incidence of negative performance indicators. Factors affecting performance measures were procedure acuity, the surgeon, and comorbidity, in order of decreasing significance. Surgeons were ranked low, middle, and high based on negative performance indicators. performance measures following oncologic procedures were significantly affected by comorbid conditions and by procedure acuity. Although the latter most strongly affects quality and performance indicators, both should weigh heavily in physician comparisons. The incidence of negative performance indicators was also influenced by the individual surgeon. These data may serve as a tool to evaluate and improve physician performance and outcomes and to develop risk-adjusted benchmarks. Ultimately, reimbursement may be tied to quantifiable measures of physician and institutional performance.
Quality of selected coals of Hungary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landis, E.R.; Rohrbacher, T.J.; Gluskoter, H.J.
2000-07-01
As part of the activities conducted under the US-Hungarian Science and Technology Fund, a total of 39 samples from five coal mines in five geologically-distinct coal areas in Hungary were selected for proximate and ultimate analyses. In addition, the heat value, forms of sulfur, free-swelling index, equilibrium moisture, Hardgrove grindability index, four-point ash fusion temperatures (both oxidizing and reducing), and apparent specific gravity were determined for each sample. Standard procedures established by the American Society for Testing and Materials (ASTM, 1999) were used. The analytical results will be available in the International Coal Quality Data Base of the USGS. Resultsmore » of the program provide data for comparison with coal quality test data from Europe and information of value to potential investors or cooperators in the coal industry of Hungary and Central Europe.« less
Towards accurate radial velocities from early type spectra in the framework of an ESO key programme
NASA Astrophysics Data System (ADS)
Verschueren, Werner; David, M.; Hensberge, Herman
In order to elucidate the internal kinematics in very young stellar groups, a dedicated machinery was set up, which made it possible to proceed from actual observations to reductions and correlation analysis to the ultimate derivation of early-type stellar radial velocities (RVs) with the requisite precision. The following ingredients are found to be essential to obtain RVs of early-type stars at the 1-km/s level of precision: high-resolution, high-S/N spectra covering a large wavelength range; maximal reduction of observational errors and the use of optimal reduction procedures; the intelligent use of a versatile cross-correlation package; and comparison of velocities derived from different regions of the spectrum in order to detect systematic mismatches between object and template spectrum in some of the lines.
Image-guided tumor ablation: proposal for standardization of terms and reporting criteria.
Goldberg, S Nahum; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John P; Rhim, Hyunchul; Silverman, Stuart G; Solbiati, Luigi; Vogl, Thomas J; Wood, Bradford J
2003-08-01
The field of image-guided tumor ablation requires standardization of terms and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments with different technologies, such as chemical ablation (ethanol or acetic acid) and thermal therapies, such as radiofrequency, laser, microwave, ultrasound, and cryoablation. On the basis of this premise, a working committee was established with the goal of producing a proposal on such standardization. The intent of the Working Group is to provide a framework that will facilitate the clearest communication between investigators and will provide the greatest flexibility in comparisons between the many new, exciting, and emerging technologies. The members of the Working Group now propose a vehicle for reporting the various aspects of image-guided ablation therapy, including classifications of therapies and procedures, appropriate descriptors of image guidance, and terms to define imaging and pathologic findings. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's hope and intention that adherence to the recommendations of this proposal will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and ultimately to improved patient outcomes. Copyright RSNA, 2003.
Image-guided tumor ablation: standardization of terminology and reporting criteria.
Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G; Solbiati, Luigi; Vogl, Thomas J; Wood, Bradford J; Vedantham, Suresh; Sacks, David
2009-07-01
The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency (RF), laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. The intent of this standardization of terminology is to provide an appropriate vehicle for reporting the various aspects of image-guided ablation therapy.
Chason, Juddson; Sausville, Justin; Kramer, Andrew C
2009-08-01
Some urologists choose not to offer penile prostheses because of concern over malpractice liability. The aim of this study was to assess whether urologists performing penile prosthesis surgery are placed at a greater malpractice risk. Percentage of malpractice suits from prosthesis surgery and other urological procedures that result in payment, average resulting payout from these cases, and category of legal issue that ultimately resulted in payout. A database from the Physician Insurers Association of America, an association of malpractice insurance companies covering physicians in North America, was analyzed to quantitatively compare penile implant surgery to other urological procedures in medicolegal terms. Compared to other common urological procedures, penile implant is comparable and on the lower end of the spectrum in terms of both the percentage of malpractice suits that result in payment and the amount ultimately paid in indemnity from those cases. Additionally, issues of informed consent play the largest role in indemnities for all urological procedures, whereas surgical technique is the most important issue for prosthesis surgery. Urologists who are adequately trained in prosthetic surgery should not avoid penile implant procedures for fear of malpractice suits. A focus on communication and informed consent can greatly reduce malpractice risk for urological procedures.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... and procedures, reduce respondent burden, and ultimately increase the quality of data collected in the... procedure: Cognitive interviews, focus groups, respondent debriefing, behavior coding of respondent... used: Mail, telephone, face-to- face, paper-and-pencil, CATI, CAPI, Internet, or IVR. III. Data OMB...
Ultimate Lateral Capacity of Rigid Pile in c- φ Soil
NASA Astrophysics Data System (ADS)
Zhang, Wei-min
2018-03-01
To date no analytical solution of the pile ultimate lateral capacity for the general c- φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ultimate lateral capacity and rotation center of rigid pile in c- φ soils were obtained. The results showed that both the dimensionless ultimate lateral capacity and dimensionless rotation center were the univariate functions of the embedded ratio. Also, the ultimate lateral capacity in the c- φ soil was the combination of the ultimate lateral capacity ( f c ) in the clay, and the ultimate lateral capacity ( f φ ) in the sand. Therefore, the Broms chart for clay, solution for clay ( φ=0) put forward by Poulos and Davis, solution for sand ( c=0) obtained by Petrasovits and Awad, and Kondner's ultimate bending moment were all proven to be the special cases of the general solution in the present study. A comparison of the field and laboratory tests in 93 cases showed that the average ratios of the theoretical values to the experimental value ranged from 0.85 to 1.15. Also, the theoretical values displayed a good agreement with the test values.
Summary of FY15 results of benchmark modeling activities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arguello, J. Guadalupe
2015-08-01
Sandia is participating in the third phase of an is a contributing partner to a U.S.-German "Joint Project" entitled "Comparison of current constitutive models and simulation procedures on the basis of model calculations of the thermo-mechanical behavior and healing of rock salt." The first goal of the project is to check the ability of numerical modeling tools to correctly describe the relevant deformation phenomena in rock salt under various influences. Achieving this goal will lead to increased confidence in the results of numerical simulations related to the secure storage of radioactive wastes in rock salt, thereby enhancing the acceptance ofmore » the results. These results may ultimately be used to make various assertions regarding both the stability analysis of an underground repository in salt, during the operating phase, and the long-term integrity of the geological barrier against the release of harmful substances into the biosphere, in the post-operating phase.« less
Restorative dentistry productivity of senior students engaged in comprehensive care.
Blalock, John S; Callan, Richard S; Lazarchik, David A; Frank Caughman, W; Looney, Stephen
2012-12-01
In dental education, various clinical delivery models are used to educate dental students. The quantitative and qualitative measures used to assess the outcomes of these models are varied. Georgia Health Sciences University College of Dental Medicine has adopted a version of a general dentistry comprehensive care dental education hybrid model. Outcome assessments were developed to evaluate the effectiveness of this delivery model. The aim of this study was to compare the number of restorative procedures performed by senior dental students under a discipline-based model versus senior student productivity engaged in comprehensive care as part of a hybrid model. The rate of senior students' productivity in performing various restorative procedures was tracked over four years, and a comparison was made. In the first two years, the seniors operated in a discipline-based model, while in the last two years the seniors operated in a comprehensive care hybrid model. The results showed that there was a significant increase in productivity by the students in terms of direct and indirect restorations. This increase in productivity may indicate that the comprehensive care model may be a more productive model, thereby enhancing clinical experiences for the students, improving operating efficiency for the schools, and ultimately increasing clinical income.
NASA Astrophysics Data System (ADS)
Obraztsov, S. M.; Konobeev, Yu. V.; Birzhevoy, G. A.; Rachkov, V. I.
2006-12-01
The dependence of mechanical properties of ferritic/martensitic (F/M) steels on irradiation temperature is of interest because these steels are used as structural materials for fast, fusion reactors and accelerator driven systems. Experimental data demonstrating temperature peaks in physical and mechanical properties of neutron irradiated pure iron, nickel, vanadium, and austenitic stainless steels are available in the literature. A lack of such an information for F/M steels forces one to apply a computational mathematical-statistical modeling methods. The bootstrap procedure is one of such methods that allows us to obtain the necessary statistical characteristics using only a sample of limited size. In the present work this procedure is used for modeling the frequency distribution histograms of ultimate strength temperature peaks in pure iron and Russian F/M steels EP-450 and EP-823. Results of fitting the sums of Lorentz or Gauss functions to the calculated distributions are presented. It is concluded that there are two temperature (at 360 and 390 °C) peaks of the ultimate strength in EP-450 steel and single peak at 390 °C in EP-823.
Ahmed, Muneeb; Solbiati, Luigi; Brace, Christopher L; Breen, David J; Callstrom, Matthew R; Charboneau, J William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gianfelice, David; Gillams, Alice R; Lee, Fred T; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J; Livraghi, Tito; Lu, David S; McGahan, John P; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L; Liang, Ping; Rhim, Hyunchul; Rose, Steven C; Salem, Riad; Sofocleous, Constantinos T; Solomon, Stephen B; Soulen, Michael C; Tanaka, Masatoshi; Vogl, Thomas J; Wood, Bradford J; Goldberg, S Nahum
2014-10-01
Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. Online supplemental material is available for this article . © RSNA, 2014.
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria—A 10-Year Update
Solbiati, Luigi; Brace, Christopher L.; Breen, David J.; Callstrom, Matthew R.; Charboneau, J. William; Chen, Min-Hua; Choi, Byung Ihn; de Baère, Thierry; Dodd, Gerald D.; Dupuy, Damian E.; Gervais, Debra A.; Gianfelice, David; Gillams, Alice R.; Lee, Fred T.; Leen, Edward; Lencioni, Riccardo; Littrup, Peter J.; Livraghi, Tito; Lu, David S.; McGahan, John P.; Meloni, Maria Franca; Nikolic, Boris; Pereira, Philippe L.; Liang, Ping; Rhim, Hyunchul; Rose, Steven C.; Salem, Riad; Sofocleous, Constantinos T.; Solomon, Stephen B.; Soulen, Michael C.; Tanaka, Masatoshi; Vogl, Thomas J.; Wood, Bradford J.; Goldberg, S. Nahum
2014-01-01
Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. © RSNA, 2014 Online supplemental material is available for this article. PMID:24927329
On the global dynamics of a chronic myelogenous leukemia model
NASA Astrophysics Data System (ADS)
Krishchenko, Alexander P.; Starkov, Konstantin E.
2016-04-01
In this paper we analyze some features of global dynamics of a three-dimensional chronic myelogenous leukemia (CML) model with the help of the stability analysis and the localization method of compact invariant sets. The behavior of CML model is defined by concentrations of three cellpopulations circulating in the blood: naive T cells, effector T cells specific to CML and CML cancer cells. We prove that the dynamics of the CML system around the tumor-free equilibrium point is unstable. Further, we compute ultimate upper bounds for all three cell populations and provide the existence conditions of the positively invariant polytope. One ultimate lower bound is obtained as well. Moreover, we describe the iterative localization procedure for refining localization bounds; this procedure is based on cyclic using of localizing functions. Applying this procedure we obtain conditions under which the internal tumor equilibrium point is globally asymptotically stable. Our theoretical analyses are supplied by results of the numerical simulation.
Time-Dependent Behavior of High-Strength Kevlar and Vectran Webbing
NASA Technical Reports Server (NTRS)
Jones, Thomas C.; Doggett, William R.
2014-01-01
High-strength Kevlar and Vectran webbings are currently being used by both NASA and industry as the primary load-bearing structure in inflatable space habitation modules. The time-dependent behavior of high-strength webbing architectures is a vital area of research that is providing critical material data to guide a more robust design process for this class of structures. This paper details the results of a series of time-dependent tests on 1-inch wide webbing including an initial set of comparative tests between specimens that underwent realtime and accelerated creep at 65 and 70% of their ultimate tensile strength. Variability in the ultimate tensile strength of the webbings is investigated and compared with variability in the creep life response. Additional testing studied the effects of load and displacement rate, specimen length and the time-dependent effects of preconditioning the webbings. The creep test facilities, instrumentation and test procedures are also detailed. The accelerated creep tests display consistently longer times to failure than their real-time counterparts; however, several factors were identified that may contribute to the observed disparity. Test setup and instrumentation, grip type, loading scheme, thermal environment and accelerated test postprocessing along with material variability are among these factors. Their effects are discussed and future work is detailed for the exploration and elimination of some of these factors in order to achieve a higher fidelity comparison.
Kottou, S; Kollaros, N; Plemmenos, C; Mastorakou, I; Apostolopoulou, S C; Tsapaki, V
2018-02-01
This study aimed to evaluate paediatric radiation doses in a dedicated cardiology hospital, with the objective of characterising patterns in dose variation. The ultimate purpose was to define Local (Institutional) Diagnostic Reference Levels (LDRLs) for different types of paediatric cardiac interventional procedures (IC), according to patient age. From a total of 710 cases performed during three consecutive years, by operators with more than 15 years of experience, the age was noted in only 477 IC procedures. The median values obtained for Fluoroscopy Time (FT), Number of Frames (N) and Kerma Area Product (P KA ) by age range were 5.8 min, 1322 and 2.0 Gy.cm 2 for <1 y; 6.5 min, 1403 and 3.0 Gy.cm 2 for 1 to <5 y; 5.9 min, 950 and 7.0 Gy.cm 2 for 5 to <10 y; 5.7 min, 940 and 14.0 Gy.cm 2 for 10 to <16 y, respectively. A large range of patient dose data is observed, depending greatly on procedure type and patient age. In all age groups the range of median FT, N and P KA values was 3.1-15.8 min, 579-1779 and 1.0-20.8 Gy.cm 2 respectively. Consequently, the definition of LDRLs presents challenges mainly due to the multiple clinical and technical factors affecting the outcome. On the other hand the lack of paediatric IC DRLs makes the identification of good practices more difficult. A consensus is needed on IC procedures nomenclature and grouping in order to allow a common assessment and comparison of doses. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Quality and Performance Indicators in an Academic Department of Head and Neck Surgery
Weber, Randal S.; Lewis, Carol M.; Eastman, Scott D.; Hanna, Ehab Y.; Akiwumi, Olubumi; Hessel, Amy C.; Lai, Stephen Y.; Kian, Leslie; Kupferman, Michael E.; Roberts, Dianna B.
2018-01-01
Objective To create a method for assessing physician performance and care outcomes that are adjusted for procedure acuity and patient comorbidity. Design Between 2004 and 2008 surgical procedures performed by 10 surgeons were stratified into high-acuity procedures (HAPs) and low-acuity procedures (LAPs). Risk adjustment was made for comorbid conditions examined singly or in groups of 2 or more. Setting A tertiary care medical center. Patients A total of 2618 surgical patients. Main Outcome Measures Performance measures included length of stay; return to operating room within 7 days of surgery; and the occurrence of mortality, hospital readmission, transfusion, and wound infection within 30 days of surgery. Results The transfusion rate was 2.7% and 40.6% for LAPs and HAPs, respectively. Wound infection rates were 1.4% for LAPs vs 14.1% for HAPs, while 30-day mortality rate was 0.3% and 1.6% for LAPs and HAPs, respectively. The mean (SD) hospital stay for LAPs was 2.1 (3.6) vs 10.5 (7.0) days for HAPs. Negative performance factors were significantly higher for patients who underwent HAPs and had comorbid conditions. Differences among surgeons significantly affect the incidence of negative performance indicators. Factors affecting performance measures were procedure acuity, the surgeon, and comorbidity, in order of decreasing significance. Surgeons were ranked low, middle, and high based on negative performance indicators. Conclusions Performance measures following oncologic procedures were significantly affected by comorbid conditions and by procedure acuity. Although the latter most strongly affects quality and performance indicators, both should weigh heavily in physician comparisons. The incidence of negative performance indicators was also influenced by the individual surgeon. These data may serve as a tool to evaluate and improve physician performance and outcomes and to develop risk-adjusted benchmarks. Ultimately, reimbursement may be tied to quantifiable measures of physician and institutional performance. PMID:21173370
Investigation on mechanical properties of basalt composite fabrics (experiment study)
NASA Astrophysics Data System (ADS)
Talebi Mazraehshahi, H.; Zamani, H.
2010-06-01
To fully appreciate the role and application of composite materials to structures, correct understanding of mechanical behaviors required for selection of optimum material. Fabric reinforced composites are composed of a matrix that is reinforced with pliable fabric, glass fabric is most popular reinforcement for different application specially in aircraft structure, although other fabric material are also used. At this study new fabric material called basalt with epoxy resin introduced and mechanical behaviors of this material investigated from view point of testing. For this study two type of fabric with different thickness used. Comparison between this composite reinforcement with popular reinforcement as carbon, glass, kevlar performed. To determine mechanical properties of epoxy based basalt fabric following test procedure performed : 1). Tensile testing according to ASTM D3039 in 0° and 90° direction to find ultimate strength in tension and shear, modulus of elasticity, elangation and ultimate strain. 2). Compression testing according to EN 2850 ultimate compression strength and maximum deformation under compression loading. 3). Shear testing according to ASTM D3518-94 to find in plane shear response of polymer matrix composites materials. 4). Predict flexural properties of sandwich construction which manufactured from basalt facing with PVC foam core according to ASTM C393-94. Material strength properties must be based on enough tests of material to meet the test procedure specifications [1]. For this reason six specimens were manufactured for testing and the tests were performed on them using an INSTRON machine model 5582. In the study, the effect of percent of resin in basalt reinforced composite was investigated. Also the weights of the ballast based composites with different percent of resin were measured with conventional composites. As the weight is an important parameter in aerospace industry when the designer wants to replace one material with another, the effect of weight must be considered. Weight measurement showed that the replacement of glass fabric reinforcement with basalt fabric has little effect on weight. Investigation also shows that mechanical behavior of basalt fabric is higher than glass fabric. This is due to the excellent mechanical properties of the ballast fabric such as Young modulus and strength in compare with the glass fabric. Figure1 shows the samples which used for tensile testing in warp direction.
Selection of pipe repair methods.
DOT National Transportation Integrated Search
2013-06-01
The objective of this research is to provide pipeline operators with testing procedures and : results of the performance of composite pipe repair methods and ultimately, improve their : selection and installation, and reduce the risks associated with...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... and safety effects, distributive impacts, and equity). Executive Order 13563 emphasizes the importance... part of order issuance. This change will ultimately help improve the management, and promotion of...
[Surgical treatment of children with brachial plexus paralysis].
Grossman, J A; Ramos, L E; Tidwell, M; Price, A; Papazian, O; Alfonso, I
1998-08-01
A variety of surgical procedures exist for early repair of the nerve injury in obstetrical brachial plexus palsy, including neuroma excision and nerve grafting, neurolysis and neurotization. Secondary deformities of the shoulder, forearm, and hand can similarly be reconstructed using soft tissue and skeletal procedures. This review describes our surgical approach to maximize the ultimate functional outcome in infants and children with obstetrical brachial plexus palsy.
LISP on a Reduced-Instruction-Set-Processor,
1986-01-01
Digital * Press, 1984. 19. Steele, G. L. Jr., and Sussman, G.J. LAMBDA : The Ultimate Imperative. Al Memo 353, MIT, Artificial ,, Inteligence Laboratory...procedure B is No 444, MIT Artificial Intelligence Laboratory, August, recursive, if procedure A can be reexecuted before the call 1977. returns. This...the programs Artificial Intelligence Programming. Lawrence Erlbaum use apply and eval, and of these three only frl uses eval Associates, Hillsdale, New
FIMic: design for ultimate 3D-integral microscopy of in-vivo biological samples
Scrofani, G.; Sola-Pikabea, J.; Llavador, A.; Sanchez-Ortiga, E.; Barreiro, J. C.; Saavedra, G.; Garcia-Sucerquia, J.; Martínez-Corral, M.
2017-01-01
In this work, Fourier integral microscope (FIMic), an ultimate design of 3D-integral microscopy, is presented. By placing a multiplexing microlens array at the aperture stop of the microscope objective of the host microscope, FIMic shows extended depth of field and enhanced lateral resolution in comparison with regular integral microscopy. As FIMic directly produces a set of orthographic views of the 3D-micrometer-sized sample, it is suitable for real-time imaging. Following regular integral-imaging reconstruction algorithms, a 2.75-fold enhanced depth of field and 2-time better spatial resolution in comparison with conventional integral microscopy is reported. Our claims are supported by theoretical analysis and experimental images of a resolution test target, cotton fibers, and in-vivo 3D-imaging of biological specimens. PMID:29359107
2013-01-01
Background Cervical facet block (FB) procedures are often used as a diagnostic precursor to radiofrequency neurotomies (RFN) in the management of chronic whiplash associated disorders (WAD). Some individuals will respond to the FB procedures and others will not respond. Such responders and non-responders provided a sample of convenience to question whether there were differences in their physical and psychological features. This information may inform future predictive studies and ultimately the clinical selection of patients for FB procedures. Methods This cross-sectional study involved 58 individuals with chronic WAD who responded to cervical FB procedures (WAD_R); 32 who did not respond (WAD_NR) and 30 Healthy Controls (HC)s. Measures included: quantitative sensory tests (pressure; thermal pain thresholds; brachial plexus provocation test); nociceptive flexion reflex (NFR); motor function (cervical range of movement (ROM); activity of the superficial neck flexors during the cranio-cervical flexion test (CCFT). Self-reported measures were gained from the following questionnaires: neuropathic pain (s-LANSS); psychological distress (General Health Questionnaire-28), post-traumatic stress (PDS) and pain catastrophization (PCS). Individuals with chronic whiplash attended the laboratory once the effects of the blocks had abated and symptoms had returned. Results Following FB procedures, both WAD groups demonstrated generalized hypersensitivity to all sensory tests, decreased neck ROM and increased superficial muscle activity with the CCFT compared to controls (p < 0.05). There were no significant differences between WAD groups (all p > 0.05). Both WAD groups demonstrated psychological distress (GHQ-28; p < 0.05), moderate post-traumatic stress symptoms and pain catastrophization. The WAD_NR group also demonstrated increased medication intake and elevated PCS scores compared to the WAD_R group (p < 0.05). Conclusions Chronic WAD responders and non-responders to FB procedures demonstrate a similar presentation of sensory disturbance, motor dysfunction and psychological distress. Higher levels of pain catastrophization and greater medication intake were the only factors found to differentiate these groups. PMID:24188899
Ultimate pier and contraction scour prediction in cohesive soils at selected bridges in Illinois
Straub, Timothy D.; Over, Thomas M.; Domanski, Marian M.
2013-01-01
The Scour Rate In COhesive Soils-Erosion Function Apparatus (SRICOS-EFA) method includes an ultimate scour prediction that is the equilibrium maximum pier and contraction scour of cohesive soils over time. The purpose of this report is to present the results of testing the ultimate pier and contraction scour methods for cohesive soils on 30 bridge sites in Illinois. Comparison of the ultimate cohesive and noncohesive methods, along with the Illinois Department of Transportation (IDOT) cohesive soil reduction-factor method and measured scour are presented. Also, results of the comparison of historic IDOT laboratory and field values of unconfined compressive strength of soils (Qu) are presented. The unconfined compressive strength is used in both ultimate cohesive and reduction-factor methods, and knowing how the values from field methods compare to the laboratory methods is critical to the informed application of the methods. On average, the non-cohesive method results predict the highest amount of scour, followed by the reduction-factor method results; and the ultimate cohesive method results predict the lowest amount of scour. The 100-year scour predicted for the ultimate cohesive, noncohesive, and reduction-factor methods for each bridge site and soil are always larger than observed scour in this study, except 12% of predicted values that are all within 0.4 ft of the observed scour. The ultimate cohesive scour prediction is smaller than the non-cohesive scour prediction method for 78% of bridge sites and soils. Seventy-six percent of the ultimate cohesive predictions show a 45% or greater reduction from the non-cohesive predictions that are over 10 ft. Comparing the ultimate cohesive and reduction-factor 100-year scour predictions methods for each bridge site and soil, the scour predicted by the ultimate cohesive scour prediction method is less than the reduction-factor 100-year scour prediction method for 51% of bridge sites and soils. Critical shear stress remains a needed parameter in the ultimate scour prediction for cohesive soils. The unconfined soil compressive strength measured by IDOT in the laboratory was found to provide a good prediction of critical shear stress, as measured by using the erosion function apparatus in a previous study. Because laboratory Qu analyses are time-consuming and expensive, the ability of field-measured Rimac data to estimate unconfined soil strength in the critical shear–soil strength relation was tested. A regression analysis was completed using a historic IDOT dataset containing 366 data pairs of laboratory Qu and field Rimac measurements from common sites with cohesive soils. The resulting equations provide a point prediction of Qu, given any Rimac value with the 90% confidence interval. The prediction equations are not significantly different from the identity Qu = Rimac. The alternative predictions of ultimate cohesive scour presented in this study assume Qu will be estimated using Rimac measurements that include computed uncertainty. In particular, the ultimate cohesive predicted scour is greater than observed scour for the entire 90% confidence interval range for predicting Qu at the bridges and soils used in this study, with the exception of the six predicted values that are all within 0.6 ft of the observed scour.
Ferguson, J Scott; Van Wert, Ryan; Choi, Yoonha; Rosenbluth, Michael J; Smith, Kate Porta; Huang, Jing; Spira, Avrum
2016-05-17
Bronchoscopy is frequently used for the evaluation of suspicious pulmonary lesions found on computed tomography, but its sensitivity for detecting lung cancer is limited. Recently, a bronchial genomic classifier was validated to improve the sensitivity of bronchoscopy for lung cancer detection, demonstrating a high sensitivity and negative predictive value among patients at intermediate risk (10-60 %) for lung cancer with an inconclusive bronchoscopy. Our objective for this study was to determine if a negative genomic classifier result that down-classifies a patient from intermediate risk to low risk (<10 %) for lung cancer would reduce the rate that physicians recommend more invasive testing among patients with an inconclusive bronchoscopy. We conducted a randomized, prospective, decision impact survey study assessing pulmonologist recommendations in patients undergoing workup for lung cancer who had an inconclusive bronchoscopy. Cases with an intermediate pretest risk for lung cancer were selected from the AEGIS trials and presented in a randomized fashion to pulmonologists either with or without the patient's bronchial genomic classifier result to determine how the classifier results impacted physician decisions. Two hundred two physicians provided 1523 case evaluations on 36 patients. Invasive procedure recommendations were reduced from 57 % without the classifier result to 18 % with a negative (low risk) classifier result (p < 0.001). Invasive procedure recommendations increased from 50 to 65 % with a positive (intermediate risk) classifier result (p < 0.001). When stratifying by ultimate disease diagnosis, there was an overall reduction in invasive procedure recommendations in patients with benign disease when classifier results were reported (54 to 41 %, p < 0.001). For patients ultimately diagnosed with malignant disease, there was an overall increase in invasive procedure recommendations when the classifier results were reported (50 to 64 %, p = 0.003). Our findings suggest that a negative (low risk) bronchial genomic classifier result reduces invasive procedure recommendations following an inconclusive bronchoscopy and that the classifier overall reduces invasive procedure recommendations among patients ultimately diagnosed with benign disease. These results support the potential clinical utility of the classifier to improve management of patients undergoing bronchoscopy for suspect lung cancer by reducing additional invasive procedures in the setting of benign disease.
A comparison of techniques for myelomeningocele defect closure in the neonatal period.
Kobraei, Edward M; Ricci, Joseph A; Vasconez, Henry C; Rinker, Brian D
2014-09-01
Numerous techniques have been described for repair of myelomeningoceles, but outcome data is scarce. A retrospective review was performed in 32 consecutive patients who underwent neonatal myelomeningocele repair and extra-dural closure to determine the influence of repair type on outcome. All procedures for myelomeningocele closure were classified into one of three groups, which included primary closure, myocutaneous flaps, and fasciocutaneous flaps. Defect size ranged from 1 to 48 cm(2). Primary skin closure was performed in 3 patients, fasciocutaneous flaps in 13 patients, and myocutaneous flaps in 16 patients. The overall complication rate was 18%. No difference in the complication rates among the primary closure, myocutaneous, and fasciocutaneous flap groups was observed in our analysis. While not statistically significant, our data documents an association of fasciocutaneous flaps with postoperative complications that were not evident with primary skin closure or myocutaneous flaps (odds ratio 3.8; p = 0.15). The occurrence of one or more complications was associated with a longer hospital stay. Myocutaneous flaps provide a secure repair and should be considered for smaller myelomeningocele defects in addition to the larger defects where they are more traditionally used. We propose a tissue-based classification of closure techniques strictly for multi-institution outcome comparison that may ultimately inform clinical decision-making.
Kannan, C; Ramanujam, R
2017-07-01
In this research work, a comparative evaluation on the mechanical and microstructural characteristics of aluminium based single and hybrid reinforced nanocomposites was carried out. The manufacture of a single reinforced nanocomposite was conducted with the distribution of 2 wt.% nano alumina particles (avg. particle size 30-50 nm) in the molten aluminium alloy of grade AA 7075; while the hybrid reinforced nanocomposites were produced with of 4 wt.% silicon carbide (avg. particle size 5-10 µm) and 2 wt.%, 4 wt.% nano alumina particles. Three numbers of single reinforced nanocomposites were manufactured through stir casting with reinforcements preheated to different temperatures viz. 400 °C, 500 °C, and 600 °C. The stir cast procedure was extended to fabricate two hybrid reinforced nanocomposites with reinforcements preheated to 500 °C prior to their inclusion. A single reinforced nanocomposite was also developed by squeeze casting with a pressure of 101 MPa. Mechanical and physical properties such as density, hardness, ultimate tensile strength, and impact strength were evaluated on all the developed composites. The microstructural observation was carried out using optical and scanning electron microscopy. On comparison with base alloy, an improvement of 63.7% and 81.1% in brinell hardness was observed for single and hybrid reinforced nanocomposites respectively. About 16% higher ultimate tensile strength was noticed with the squeeze cast single reinforced nanocomposite over the stir cast.
Gupt, Parikshit; Nagpal, Archana; Samra, Rupandeep Kaur; Verma, Ramit; Kaur, Jasjeet; Abrol, Surbhi
2017-01-01
The purpose of the study was to evaluate the fracture strength of provisional fixed partial dentures made of autopolymerizing polymethylmethacrylate (PMMA) resin using different types of reinforcement materials to determine the best among them. Fifty samples were made (10 samples for each group) with autopolymerizing PMMA resin using reinforcement materials (stainless steel wire: looped and unlooped and glass fiber: loose and unidirectional) as 3-unit posterior bridge. The test specimens were divided into five groups depending on the reinforcing material as Group I, II, III, IV, and V; Group I: PMMA unreinforced (control group), Group II: PMMA reinforced with stainless steel wire (straight ends), Group III: PMMA reinforced with stainless steel wire (looped ends), Group IV: PMMA reinforced with unidirectional glass fibers, and Group V: PMMA reinforced with randomly distributed glass fibers. Universal testing machine was used to evaluate and compare the fracture strength of samples. Comparison of mean ultimate force and ultimate stress was done employing one-way analysis of variance and Tukey's post hoc tests. The highest and lowest mean ultimate force and mean ultimate stress were of Group IV and I, respectively. Tukey's post hoc honestly significant difference multiple comparison for mean ultimate force and stress shows the increase in strength to be statistically significant ( P < 0.05) except for the samples reinforced with randomly distributed glass fibers ( P > 0.05). Unidirectional glass fibers showed the maximum strength, which was comparable to mean values of both stainless steel wire groups. Low cost and easy technique of using stainless steel wire make it the material of choice over the unidirectional glass fiber for reinforcement in nonesthetic areas where high strength is required.
Garcia, Joel A; Casserly, Ivan P
2009-07-01
An increasing spectrum of complex peripheral arterial disease may be successfully treated using percutaneous revascularization techniques. A pair of challenging peripheral revascularization procedures in patients with critical limb ischemia is presented, where an array of interventional tools and techniques were required, and the off-label use of the Boomerang catalyst system closure device was important in managing a variety of complex arterial access issues and ultimately allowing procedural success. Copyright 2009 Wiley-Liss, Inc.
Nakyinsige, K; Sazili, A Q; Zulkifli, I; Goh, Y M; Abu Bakar, F; Sabow, A B
2014-12-01
This study assessed the effect of gas stunning which has not been conducted until now in comparison with slaughter without stunning on the welfare and meat quality of rabbits. Eighty male New Zealand White rabbits were divided into two groups of 40 animals and subjected to either halal slaughter without stunning (HS) or gas stunning using 61.4% CO2, 20.3% oxygen and 18.3 % nitrogen (GS). Analysis of the sticking blood revealed that both slaughter procedures caused a substantial increase in the levels of catecholamines, hypercalcemia, hyperglycemia, lactic acidemia and an increase in enzyme activities. The ultimate pH of the Longissimus lumborum muscle did not differ between treatments. GS exhibited higher lightness and cooking loss, and lower glycogen and MFI than HS. This indicates that both GS and HS can be significant stressors although the amount of stress may be below the threshold to negatively affect rabbit meat quality. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tensile bond strength of an aged resin composite repaired with different protocols.
Celik, Esra Uzer; Ergücü, Zeynep; Türkün, L Sebnem; Ercan, Utku Kürșat
2011-08-01
To evaluate the effect of different surface treatments and bonding procedures on the tensile bond strength (TBS) of resin composites repaired 6 months after polymerization. Resin composite sticks were aged in distilled water at 37°C for 6 months. They were divided into 12 groups (n = 10) according to the combination of surface treatment/bonding procedures [none, only bur treatment, XP Bond (XPB/Dentsply/DeTrey) with/without bur, AdheSE (A-SE/Ivoclar/Vivadent) with/without bur, Composite Primer (CP/GC) with/without bur, CP after bur and acid-etching, XPB after acid etching and CP with bur, A-SE after bur and CP]. The ultimate tensile bond strength (UTS) of the resin composites was tested in intact but aged specimens. Tensile bond strengths were tested with a universal testing machine (Shimadzu). Data were analyzed using one-way ANOVA and Duncan Multiple Comparisons tests (p < 0.05). All repaired groups showed significantly higher TBS than the group without any sureface treatment (p < 0.05). Four groups resulted in TBS similar to those of intact resin composite UTS: A-SE, A-SE with bur, A-SE after CP with bur, and XPB after acid etching+CP with bur. Bur treatment, silane primer or etch-and-rinse adhesive application alone were not successful in the repair process of aged resin composite, whereas self-etching adhesive alone showed similar performance to the intact specimens. Combined procedures generally showed better performance: A-SE with bur, A-SE after CP with bur, and XPB after acid etching +CP with bur showed TBS similar to those of the intact specimens. It was concluded that bur roughening of the surfaces and rebonding procedures were essential for repairing aged resin composites.
On evaluating clustering procedures for use in classification
NASA Technical Reports Server (NTRS)
Pore, M. D.; Moritz, T. E.; Register, D. T.; Yao, S. S.; Eppler, W. G. (Principal Investigator)
1979-01-01
The problem of evaluating clustering algorithms and their respective computer programs for use in a preprocessing step for classification is addressed. In clustering for classification the probability of correct classification is suggested as the ultimate measure of accuracy on training data. A means of implementing this criterion and a measure of cluster purity are discussed. Examples are given. A procedure for cluster labeling that is based on cluster purity and sample size is presented.
The legal and ethical implications of consent to nursing procedures.
Power, K J
Nurses are increasingly expanding their practice to include many more invasive procedures. Consequently, there is a need to re-examine nurses' responsibilities in relation to obtaining consent for nursing as opposed to medical procedures. Fully informed consent is not a legal requirement in England, for either medical or nursing procedures. However, this article argues that to comply with the standard set by the Code of Professional Conduct nurses should obtain informed consent for any proposed procedure they undertake. The concept of informed consent is examined and applied to practice. Ultimately, nurses are charged with four key tasks in relation to securing consent for nursing procedures: educating themselves about the risks and benefits of the procedures they propose to undertake; conveying this information to patients; assessing their understanding of the information given; and endeavouring to support the patient in his/her decision.
Cai, Yu-Long; Song, Pei-Pei; Tang, Wei; Cheng, Nan-Sheng
2016-06-01
The main obstacle to achieving an R0 resection after a major hepatectomy is inability to preserve an adequate future liver remnant (FLR) to avoid postoperative liver failure (PLF). Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) is a novel technique for resecting tumors that were previously considered unresectable, and this technique results in a vast increase in the volume of the FLR in a short period of time. However, this technique continues to provoke heated debate because of its high mortality and morbidity.The evolution of ALPPS and its advantages and disadvantages have been systematically reviewed and evaluated in accordance with current evidence. Electronic databases (PubMed and Medline) were searched for potentially relevant articles from January 2007 to January 2016.ALPPS has evolved into various modified forms. Some of these modified techniques have reduced the difficulty of the procedure and enhanced its safety. Current evidence indicates that the advantages of ALPPS are rapid hypertrophy of the FLR, the feasibility of the procedure, and a higher rate of R0 resection in comparison to other techniques. However, ALPPS is associated with worse major complications, more deaths, and early tumor recurrence.Hepatobiliary surgeons should carefully consider whether to perform ALPPS. Some modified forms of ALPPS have reduced the mortality and morbidity of the procedure, but they cannot be recommended over the original procedure currently. Portal vein embolization (PVE) is still the procedure of choice for patients with a tumor-free FLR, and ALPPS could be used as a salvage procedure when PVE fails. More persuasive evidence needs to be assembled to determine whether ALPPS or two-stage hepatectomy (TSH) is better for patients with a tumor involving the FLR. Evidence with regard to long-term oncological outcomes is still limited. More meticulous comparative studies and studies of the 5-year survival rate of ALPPS could ultimately help to determine the usefulness of ALPPS. Indications and patient selection for the procedure need to be determined.
Cai, Yu-Long; Song, Pei-Pei; Tang, Wei; Cheng, Nan-Sheng
2016-01-01
Abstract The main obstacle to achieving an R0 resection after a major hepatectomy is inability to preserve an adequate future liver remnant (FLR) to avoid postoperative liver failure (PLF). Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) is a novel technique for resecting tumors that were previously considered unresectable, and this technique results in a vast increase in the volume of the FLR in a short period of time. However, this technique continues to provoke heated debate because of its high mortality and morbidity. The evolution of ALPPS and its advantages and disadvantages have been systematically reviewed and evaluated in accordance with current evidence. Electronic databases (PubMed and Medline) were searched for potentially relevant articles from January 2007 to January 2016. ALPPS has evolved into various modified forms. Some of these modified techniques have reduced the difficulty of the procedure and enhanced its safety. Current evidence indicates that the advantages of ALPPS are rapid hypertrophy of the FLR, the feasibility of the procedure, and a higher rate of R0 resection in comparison to other techniques. However, ALPPS is associated with worse major complications, more deaths, and early tumor recurrence. Hepatobiliary surgeons should carefully consider whether to perform ALPPS. Some modified forms of ALPPS have reduced the mortality and morbidity of the procedure, but they cannot be recommended over the original procedure currently. Portal vein embolization (PVE) is still the procedure of choice for patients with a tumor-free FLR, and ALPPS could be used as a salvage procedure when PVE fails. More persuasive evidence needs to be assembled to determine whether ALPPS or two-stage hepatectomy (TSH) is better for patients with a tumor involving the FLR. Evidence with regard to long-term oncological outcomes is still limited. More meticulous comparative studies and studies of the 5-year survival rate of ALPPS could ultimately help to determine the usefulness of ALPPS. Indications and patient selection for the procedure need to be determined. PMID:27311006
Use of Metallic Endosseous Implants as a Tooth Substitute.
1979-06-01
exposed in the oral cavity and placed in function with the opposing dentition iBACKGROUND The development of a dental implant that will serve as a...contract year was spent in testing the dental implant as a single tooth replacement. The ultimate goal of this implant study was to develop a free-standing...to read and sign an informed consent form. SURGICAL PROCEDURES The dental implant was inserted into the edentulous area using the exact procedures as
1992-12-01
current repair policies and procedures within this shop. We offer some ideas and suggestions for changing and improving existing operations and the...implementing and focusing continual improvements in Shop 93302 and ultimately in the depot as a whole. 20. DISTRIBUTION/AVAILABILITY OF ABSTRACT 21...used to evaluate current repair policies and procedures within this shop. We also offer some ideas and suggestions for changing and improving existing
Nondestructive x-ray Scattering Characterization of High Temperature Superconducting Wires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thurston, T R
The purpose of this CRADA was to characterize the structural properties of the superconductor material within the wires in order to determine which processing procedures produce the best superconductor texture and phase development, and hence the best ultimate current carrying capacity.
40 CFR 80.141 - Interim detergent gasoline program.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) “Carburetor Cleanliness Test Procedure, State-of-the-Art Summary, Report: 1973-1981”, Coordinating Research... ultimate consumer; (ii) All additized post-refinery component (PRC); and (iii) All detergent additives sold... who manufacture, supply, or transfer detergent additives or detergent-additized post-refinery...
Buyuk, S Kutalmış; Kucukekenci, Ahmet Serkan
2018-03-01
To investigate the shear bond strength (SBS) of orthodontic metal brackets applied to different types of ceramic surfaces treated with different etching procedures and bonding agents. Monolithic CAD/CAM ceramic specimens (N = 120; n = 40 each group) of feldspathic ceramic Vita Mark II, resin nanoceramic Lava Ultimate, and hybrid ceramic Vita Enamic were fabricated (14 × 12 × 3 mm). Ceramic specimens were separated into four subgroups (n = 10) according to type of surface treatment and bonding onto the ceramic surface. Within each group, four subgroups were prepared by phosphoric acid, hydrofluoric acid, Transbond XT primer, and Clearfill Ceramic primer. Mandibular central incisor metal brackets were bonded with light-cure composite. The SBS data were analyzed using three-way analysis of variance (ANOVA) and Tukey HSD tests. The highest SBS was found in the Vita Enamic group, which is a hybrid ceramic, etched with hydrofluoric acid and applied Transbond XT Adhesive primer (7.28 ± 2.49 MPa). The lowest SBS was found in the Lava Ultimate group, which is a resin nano-ceramic etched with hydrofluoric acid and applied Clearfill ceramic primer (2.20 ± 1.21 MPa). CAD/CAM material types and bonding procedures affected bond strength ( P < .05), but the etching procedure did not ( P > .05). The use of Transbond XT as a primer bonding agent resulted in higher SBS.
NASA Astrophysics Data System (ADS)
Dubey, Shailendra Kumar Damodar; Kute, Sunil
2014-09-01
Due to earthquake, buildings are damaged partially or completely. Particularly structures with soft storey are mostly affected. In general, such damaged structures are repaired and reused. In this regard, an experimental investigation was planned and conducted on models of single-bay, single-storey of partial concrete infilled reinforced concrete (RC) frames up to collapse with corner, central and diagonal steel bracings. Such collapsed frames were repaired with epoxy resin and retested. The initiative was to identify the behaviour, extent of restored ultimate strength and deflection of epoxy-retrofitted frames in comparison to the braced RC frames. The performance of such frames has been considered only for lateral loads. In comparison to bare RC frames, epoxy repaired partial infilled frames have significant increase in the lateral load capacity. Central bracing is more effective than corner and diagonal bracing. For the same load, epoxy repaired frames have comparable deflection than similar braced frames.
Polarization of perceived Procedural Justice.
Flint, Douglas H; Hernandez-Marrero, Pablo; Wielemaker, Martin
2006-02-01
This study examined polarization of perceptions of Procedural Justice. Two polarization mechanisms are examined, Persuasive Arguments and Social Comparisons. Participants were students enrolled in a first-year introductory business class. There were 216 participants in the Persuasive Arguments study, 429 in the Social Comparisons study. The average age of all participants was 22.3 yr. (SD = 2.1); 56% were women. Fields of study represented were business, engineering, information technology, and sports. Analysis showed under conditions of low Procedural Justice, polarization effects were only found with the Persuasive Arguments mechanism. Under conditions of high Procedural Justice, polarization effects were only found with Social Comparisons. Implications for group polarization and Procedural Justice theories are considered.
Student Discipline Data Tracker v.1
ERIC Educational Resources Information Center
Steel, Lawrence E.
2005-01-01
One of the most difficult tasks facing today's busy school administrative teams is tracking and managing student discipline. Administrators must balance the rights of students with cultivating classroom environments conducive to learning. Breakdowns in communication, procedure, and due process can lead to unpleasant situations, and ultimately, a…
Degassing procedure for ultrahigh vacuum
NASA Technical Reports Server (NTRS)
Moore, B. C.
1979-01-01
Calculations based on diffusion coefficients and degassing rates for stainless-steel vacuum chambers indicate that baking at lower temperatures for longer periods give lower ultimate pressures than rapid baking at high temperatures. Process could reduce pressures in chambers for particle accelerators, fusion reactors, material research, and other applications.
40 CFR 86.1228-85 - Transmissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Test Procedures for New Gasoline-Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas-Fueled and... manufacturer's recommendation to the ultimate purchaser. (b) Except for the first idle mode, idle modes less...; manual transmissions shall be in gear with the clutch disengaged, except first idle. The first idle mode...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron; Sengupta, Manajit; Andreas, Afshin
Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibrationmore » service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These different methods of calibration demonstrated +1% to +2% differences in solar irradiance measurement. Analyzing these differences will ultimately help determine the uncertainty of the field radiometer data and guide the development of a consensus standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainty will allow more accurate prediction of solar output and improve the bankability of solar projects.« less
Surgery for benign prostatic hyperplasia: Profile of patients in a tertiary care institution.
Rajeev, Rahul; Giri, Bhuwan; Choudhary, Lok Prakash; Kumar, Rajeev
2017-01-01
Medical therapy is widely used for managing benign prostatic hyperplasia (BPH) and has made an impact on the profile of patients who ultimately undergo surgery. This changing profile may impact outcomes of surgery and associated complications. To assess the impact of medical management, we evaluated the profile of patients who had surgery for BPH at our institution. A retrospective chart-review was performed of patient demographics, indications for surgery, preoperative comorbid conditions and postoperative course in patients who underwent surgery for BPH over a 5-year period. The data were analysed for demographic trends in comparison with historical cohorts. A total of 327 patients underwent surgery for BPH between 2008 and 2012. Their mean age was 66.4 years, the mean prostate gland weight was 59.2 g and the mean duration of symptoms was 35.3 months; 34% had a prostate gland weight of >60 g; 1 59 (48.6%) patients had an absolute indication for surgery; 139 (42.5%) of these were catheterized and 6.1% of patients presented with azotaemia or upper tract changes without urinary retention. In comparison with historical cohorts, more patients are undergoing surgery for absolute indications including retention of urine and hydroureteronephrosis. However, the patients are younger, they have fewer comorbid conditions and have a similar rate of complications after the procedure.
32 CFR 231.5 - Procedures-domestic banks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the TGA. (vi) A list of organizational and nonappropriated fund accounts, the name and location of... surveillance equipment, when necessary. (ix) Reasons for use of space controlled by the General Services... solicitation. Proposals shall be evaluated and ultimate selection made based upon the factors and weights...
Global, long-term surface reflectance records from Landsat
USDA-ARS?s Scientific Manuscript database
Global, long-term monitoring of changes in Earth’s land surface requires quantitative comparisons of satellite images acquired under widely varying atmospheric conditions. Although physically based estimates of surface reflectance (SR) ultimately provide the most accurate representation of Earth’s s...
Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.
Chung, Hyun Kee; Lightdale, Jenifer R
2016-07-01
Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.
Interface bonding of shotcrete reinforced brick masonry assemblages, volume 1
NASA Astrophysics Data System (ADS)
Robinson, D. W.; Kahn, L. F.
1982-09-01
Nine 9 sq ft. shotcrete reinforced brick masonry assemblages and one 9 sq ft brick masonry control specimen were tested under a single reversed cycle diagonal compression load similar to the ASTM E519-74 testing procedures. The interface surface conditions, between the brick and shotcrete were varied. The surfaces of the single sythe of old brick were either dry, wet, or epoxy coated before application of the 3-inch reinforced shotcrete layer. Ultimate load capacities of the specimens were similar, however, specimens with epoxy-enhanced interfaces were the most ductile; the dry brick specimens showed interface bond failure immediately after the ultimate inplane load was attained.
Chronic pancreatitis: A surgical disease? Role of the Frey procedure
Roch, Alexandra; Teyssedou, Jérome; Mutter, Didier; Marescaux, Jacques; Pessaux, Patrick
2014-01-01
Although medical treatment and endoscopic interventions are primarily offered to patients with chronic pancreatitis, approximately 40% to 75% will ultimately require surgery during the course of their disease. Although pancreaticoduodenectomy has been considered the standard surgical procedure because of its favorable results on pain control, its high postoperative complication and pancreatic exocrine or/and endocrine dysfunction rates have led to a growing enthusiasm for duodenal preserving pancreatic head resection. The aim of this review is to better understand the rationale underlying of the Frey procedure in chronic pancreatitis and to analyze its outcome. Because of its hybrid nature, combining both resection and drainage, the Frey procedure has been conceptualized based on the pathophysiology of chronic pancreatitis. The short and long-term outcome, especially pain relief and quality of life, are better after the Frey procedure than after any other surgical procedure performed for chronic pancreatitis. PMID:25068010
Interventional robotic systems: Applications and technology state-of-the-art
CLEARY, KEVIN; MELZER, ANDREAS; WATSON, VANCE; KRONREIF, GERNOT; STOIANOVICI, DAN
2011-01-01
Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere. PMID:16754193
Transcatheter therapy for hepatic malignancy: standardization of terminology and reporting criteria.
Brown, Daniel B; Gould, Jennifer E; Gervais, Debra A; Goldberg, S Nahum; Murthy, Ravi; Millward, Steven F; Rilling, William S; Geschwind, Jean-Francois S; Salem, Riad; Vedantham, Suresh; Cardella, John F; Soulen, Michael C
2009-07-01
The field of interventional oncology includes tumor ablation as well as the use of transcatheter therapies such as embolization, chemoembolization, and radioembolization. Terminology and reporting standards for tumor ablation have been developed. The development of standardization of terminology and reporting criteria for transcatheter therapies should provide a similar framework to facilitate the clearest communication among investigators and provide the greatest flexibility in comparing established and emerging technologies. An appropriate vehicle for reporting the various aspects of catheter directed therapy is outlined, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings. Methods for standardizing the reporting of outcomes toxicities, complications, and other important aspects that require attention when reporting clinical results are addressed. It is the intention of the group that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication for reporting the various aspects of transcatheter management of hepatic malignancy that will translate to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... event of conflict between a delivery order or task order and this contract, the contract shall control.... This change will ultimately help improve the management and promotion of electronic Government services... impose any information collection requirements that require the approval of the Office of Management and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-22
... Administration, Attention: DEA Federal Register Representative/ODL, 8701 Morrissette Drive, Springfield, VA 22152..., Office of Diversion Control, Drug Enforcement Administration, 8701 Morrissette Drive, Springfield, VA... 2006. Teens abuse prescription drugs more than any illicit drug except marijuana--more than cocaine...
Thoughts on the chimera method of simulation of three-dimensional viscous flow
NASA Technical Reports Server (NTRS)
Steger, Joseph L.
1991-01-01
The chimera overset grid is reviewed and discussed relative to other procedures for simulating flow about complex configurations. It is argued that while more refinement of the technique is needed, current schemes are competitive to unstructured grid schemes and should ultimately prove more useful.
7 CFR 4280.311 - Loan provisions for Agency loans to microlenders.
Code of Federal Regulations, 2011 CFR
2011-01-01
... administer by making and servicing microloans in one or more rural areas. (b) Eligible activities... the microlender's lending policies and procedures shall limit the microlender's loan to the... will accrue interest at a rate of 1 or 2 percent based on the ultimate interest rate on the loan...
7 CFR 4280.311 - Loan provisions for Agency loans to microlenders.
Code of Federal Regulations, 2014 CFR
2014-01-01
... administer by making and servicing microloans in one or more rural areas. (b) Eligible activities... the microlender's lending policies and procedures shall limit the microlender's loan to the... will accrue interest at a rate of 1 or 2 percent based on the ultimate interest rate on the loan...
USDA-ARS?s Scientific Manuscript database
Initial efforts by the poultry industry at controlling and containing Mycoplasma gallisepticum (MG) included testing and slaughter of reactor flocks. Ultimately, using the aforementioned measures coupled with heat treatment of hatching eggs together with biosecurity and biosurveillance procedures, ...
Accurate and affordable physicochemical characterization of commercial engineered nanomaterials is required for toxicology studies to ultimately determine nanomaterial: hazard identification; dose to response metric(s); and mechanism(s) of injury. A minimal physical and chemica...
A new design concept for knitted external vein-graft support mesh.
Singh, Charanpreet; Wang, Xungai
2015-08-01
Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights reserved.
An Experimental Investigation on the Ultimate Strength of Partially Infilled: Braced Steel Frames
NASA Astrophysics Data System (ADS)
Dubey, Shailendra Kumar Damodar; Kute, Sunil Y.
2017-12-01
Infilled walls are usually, considered as non-structural elements. However, these walls are effective in carrying lateral loads. In this regard, an experimental investigation was planned and conducted to study the effect of braced and partially infilled steel frames with cement mortar and concrete in comparison to the bare frames. All these frames were tested up to collapse and subjected only to horizontal loads to obtain an effective and possible solution for soft storey which are generally not infilled. In comparison to bare steel frames, partially infilled frames have an increase of lateral load capacity by 45-60%. Central bracing is more effective than that of the corner bracing. For the same load partially infilled frames have significantly less deflection than that of the bare frames. A reduced load factor is suggested for the design of soft storey columns with the partial infills. A mathematical model has been proposed to calculate the theoretical ultimate load for the braced, cement mortar and concrete partial infilled frames.
Formago, Margaret; Schrauder, Michael G.; Rauh, Claudia; Hack, Carolin C.; Jud, Sebastian M.; Hildebrandt, Thomas; Schulz-Wendtland, Rüdiger; Frentz, S.; Graubert, S.; Beckmann, Matthias W.; Lux, Michael P.
2017-01-01
Introduction The care of patients with breast cancer is extremely complex and requires interdisciplinary care in certified facilities. These specialized facilities provide numerous services without being correspondingly remunerated. The question whether breast cancer surgery should be performed in an outpatient setting to reduce costs is increasingly being debated. This study compares inpatient surgical treatment with a model of the same surgery performed on an outpatient basis to examine the potential financial impact. Material and Methods A theoretical model was developed and the DRG fees for surgical interventions to treat primary breast cancer were calculated. A theoretical 1-day DRG was then calculated to permit comparisons with outpatient procedures. The costs of outpatient surgery were calculated based on the remuneration rates of the AOP (Outpatient Surgery) Contract and the EBM (Uniform Assessment Scale) and compared to the costs of the 1-day DRG. Results The DRG fee for both breast-conserving surgery and mastectomy is higher than the fee paid in the context of the EBM system, although the same procedures were carried out in both systems. If a hospital were to carry out breast-conserving surgery as an outpatient procedure, the fee would be € 1313.81; depending on the type of surgery, the hospital would therefore only receive between 39.20% and 52.82% of the DRG fee. This was the case even for a 1-day treatment. Compared to the real DRG fees the difference would be even more striking. Conclusion Carrying out breast cancer surgery as an outpatient procedure would result in a significant shortfall of revenues. Additional services from certified centers, such as the interdisciplinary planning of treatment, psycho-oncological and social-medical care with the involvement of relatives, detailed documentation, etc., which are currently provided without surcharge or adequate remuneration, could no longer be maintained. The quality of processes and excellent results which have been achieved and ultimately the care given by certified facilities would be significantly at risk. PMID:28845052
Formago, Margaret; Schrauder, Michael G; Rauh, Claudia; Hack, Carolin C; Jud, Sebastian M; Hildebrandt, Thomas; Schulz-Wendtland, Rüdiger; Frentz, S; Graubert, S; Beckmann, Matthias W; Lux, Michael P
2017-08-01
The care of patients with breast cancer is extremely complex and requires interdisciplinary care in certified facilities. These specialized facilities provide numerous services without being correspondingly remunerated. The question whether breast cancer surgery should be performed in an outpatient setting to reduce costs is increasingly being debated. This study compares inpatient surgical treatment with a model of the same surgery performed on an outpatient basis to examine the potential financial impact. A theoretical model was developed and the DRG fees for surgical interventions to treat primary breast cancer were calculated. A theoretical 1-day DRG was then calculated to permit comparisons with outpatient procedures. The costs of outpatient surgery were calculated based on the remuneration rates of the AOP (Outpatient Surgery) Contract and the EBM (Uniform Assessment Scale) and compared to the costs of the 1-day DRG. The DRG fee for both breast-conserving surgery and mastectomy is higher than the fee paid in the context of the EBM system, although the same procedures were carried out in both systems. If a hospital were to carry out breast-conserving surgery as an outpatient procedure, the fee would be € 1313.81; depending on the type of surgery, the hospital would therefore only receive between 39.20% and 52.82% of the DRG fee. This was the case even for a 1-day treatment. Compared to the real DRG fees the difference would be even more striking. Carrying out breast cancer surgery as an outpatient procedure would result in a significant shortfall of revenues. Additional services from certified centers, such as the interdisciplinary planning of treatment, psycho-oncological and social-medical care with the involvement of relatives, detailed documentation, etc., which are currently provided without surcharge or adequate remuneration, could no longer be maintained. The quality of processes and excellent results which have been achieved and ultimately the care given by certified facilities would be significantly at risk.
Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O
2012-11-01
Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than the intact, uninjured ATFL. Biomechanically, the results show that both suture anchor and direct suture repair of the ATFL provide similar strength and stiffness. Unfortunately, these methods provide less than half the strength and stiffness of the native ATFL at time zero. As a result, regardless of the repair method, it is necessary to sufficiently protect the repair to avoid premature failure.
Nanocrystal synthesis in microfluidic reactors: where next?
Phillips, Thomas W; Lignos, Ioannis G; Maceiczyk, Richard M; deMello, Andrew J; deMello, John C
2014-09-07
The past decade has seen a steady rise in the use of microfluidic reactors for nanocrystal synthesis, with numerous studies reporting improved reaction control relative to conventional batch chemistry. However, flow synthesis procedures continue to lag behind batch methods in terms of chemical sophistication and the range of accessible materials, with most reports having involved simple one- or two-step chemical procedures directly adapted from proven batch protocols. Here we examine the current status of microscale methods for nanocrystal synthesis, and consider what role microreactors might ultimately play in laboratory-scale research and industrial production.
Otto, Markus; Bowser, Robert; Turner, Martin; Berry, James; Brettschneider, Johannes; Connor, James; Costa, Júlia; Cudkowicz, Merit; Glass, Jonathan; Jahn, Olaf; Lehnert, Stefan; Malaspina, Andrea; Parnetti, Lucilla; Petzold, Axel; Shaw, Pamela; Sherman, Alexander; Steinacker, Petra; Süssmuth, Sigurd; Teunissen, Charlotte; Tumani, Hayrettin; Wuolikainen, Anna; Ludolph, Albert
2012-01-01
Despite major advances in deciphering the neuropathological hallmarks of amyotrophic lateral sclerosis (ALS), validated neurochemical biomarkers for monitoring disease activity, earlier diagnosis, defining prognosis and unlocking key pathophysiological pathways are lacking. Although several candidate biomarkers exist, translation into clinical application is hindered by small sample numbers, especially longitudinal, for independent verification. This review considers the potential routes to the discovery of neurochemical markers in ALS, and provides a consensus statement on standard operating procedures that will facilitate multicenter collaboration, validation and ultimately clinical translation.
2014-01-01
Background Improper workstation, work procedures and tools are found to be the risk factors for the development of musculoskeletal disorders among the informal sector workers of the developing countries. Low cost ergonomic interventions can effectively improve such adverse conditions. Case presentation In the present article some studies related to design interventions in different informal and agricultural sectors were discussed and their efficacies were analyzed. It was observed that with the help of appropriate interventions musculoskeletal disorders were reduced, adverse physiological conditions were improved when awkward postures were corrected and ultimately the organisational productivity was increased. Conclusion Proper implementation of ergonomic interventions can ultimately improve the economy of the nation. PMID:25009740
Micro-mass standards to calibrate the sensitivity of mass comparators
NASA Astrophysics Data System (ADS)
Madec, Tanguy; Mann, Gaëlle; Meury, Paul-André; Rabault, Thierry
2007-10-01
In mass metrology, the standards currently used are calibrated by a chain of comparisons, performed using mass comparators, that extends ultimately from the international prototype (which is the definition of the unit of mass) to the standards in routine use. The differences measured in the course of these comparisons become smaller and smaller as the standards approach the definitions of their units, precisely because of how accurately they have been adjusted. One source of uncertainty in the determination of the difference of mass between the mass compared and the reference mass is the sensitivity error of the comparator used. Unfortunately, in the market there are no mass standards small enough (of the order of a few hundreds of micrograms) for a valid evaluation of this source of uncertainty. The users of these comparators therefore have no choice but to rely on the characteristics claimed by the makers of the comparators, or else to determine this sensitivity error at higher values (at least 1 mg) and interpolate from this result to smaller differences of mass. For this reason, the LNE decided to produce and calibrate micro-mass standards having nominal values between 100 µg and 900 µg. These standards were developed, then tested in multiple comparisons on an A5 type automatic comparator. They have since been qualified and calibrated in a weighing design, repeatedly and over an extended period of time, to establish their stability with respect to oxidation and the harmlessness of the handling and storage procedure associated with their use. Finally, the micro-standards so qualified were used to characterize the sensitivity errors of two of the LNE's mass comparators, including the one used to tie France's Platinum reference standard (Pt 35) to stainless steel and superalloy standards.
An Alternative Approach to Identifying a Dimension in Second Language Proficiency.
ERIC Educational Resources Information Center
Griffin, Patrick E.; And Others
Current practice in language testing has not yet integrated classical test theory with assessment of language skills. In addition, language testing needs to be part of theory development. Lack of sound testing procedures can lead to problems in research design and ultimately, inappropriate theory development. The debate over dimensionality of…
ERIC Educational Resources Information Center
Doughty, Howard A.; Kenney, Lorne J.
2011-01-01
Innovation should be about procedures and methods. Little thought is given to proximate, much less ultimate aims. In this article, the authors invite educators to take a break and explore the educational enterprise to which they devote their life's work. They discuss two bits of excerpted writing, both over half a century old. One comes from Jack…
MRT 5711 - Scope Radiochemical Analysis Comparison: Joint LANL-LLNL FY17 L-2 Milestone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murray, S. D.; Lee, A. S.
A 2016 Level-1 milestone highlighted surprising differences in fundamental data used by the two US design laboratories. To better understand and ultimately resolve those differences, two Level-2 milestones were developed for execution in FY-17 and FY-18.
Landfills are the ultimate reactors for biodegradation as they contain nutrients, bacteria, and various redox conditions which, then, change over time. Enhancement of the landill environment to optimize the rates of biodegradation and to ensure more rapid stabilization of the was...
Goff, B A; Muntz, H G; Cain, J M
1997-08-01
On January 1, 1992, Congress implemented a Medicare payment system based on relative value units (RVUs). The total RVU (which is made up of work, practice, and malpractice RVUs) is multiplied by a dollar conversion factor to set the reimbursement for all procedures covered by Medicare. In a previous study, we found that significant gender bias exists in Medicare reimbursement for female-specific services. Recently, HCFA approved increases (beginning January 1997) in the work RVU for many gynecologic procedures. This study was undertaken to compare work and total RVUs for gender-specific procedures effective January 1, 1997. Using the May 1996 Federal Register, we compared work and total RVUs for 24 pairs of gender-specific procedures. The groups were matched so that the amount of work and level of difficulty would be similar, if not identical. We validated our selection of procedures for comparison by also evaluating the average time required to perform these procedures. Comparison of work RVUs for the 24 paired procedures revealed that in 19 cases (80%), male-specific procedures had a higher RVU; in 3 cases (12%), female-specific procedures were higher; and in 2 cases, there was no difference. On average, work RVUs were 49% higher for urologic procedures than for gynecologic procedures. Comparison of total RVUs revealed that in 20 cases (83%), urologic procedures had a higher total RVU and in 3 cases (12%), gynecologic procedures were higher. On average, male-specific surgeries are reimbursed at an amount which is 37% higher than that for female-specific surgeries. Recent increases in work RVUs for many gynecologic procedures have resulted in improved reimbursement. However, even with these improvements, significant gender bias still exists in the Medicare reimbursement of female-specific procedures. This gender bias is further magnified as more private insurance carriers use the system to set reimbursement.
Geographic applications of ERTS-1 imagery to rural landscape change in eastern Tennessee
NASA Technical Reports Server (NTRS)
Rehder, J. B. (Principal Investigator); Omalley, J. R.
1973-01-01
There are no author-identified significant results in this report. A multistage sampling experiment was conducted using low (10,000') and high (60,000') altitude aircraft imagery in comparison with orbital (560 miles) ERTS imagery. Although the aircraft data provide detailed landscape observations similar to ground truth data, they cover relatively small areas per image frame for irregular static slices of time. By comparison, ERTS provides repetitive observations in a regional perspective for broad areal coverage. Microdensitometric and computer techniques are being used to analyze the ERTS imagery for gray tone signatures, comparisons, and ultimately for landscape change detection.
ERIC Educational Resources Information Center
Kademan, Robyn
2005-01-01
One of the most beneficial uses for technology in the science classroom is data manipulation. During labs and other learning experiences, students can quickly put the data they collect into spreadsheets or databases. Then they can make comparisons, create graphs, draw conclusions, sort the data in new ways, and, ultimately, give their data…
Huang, Zhen
2017-01-01
This paper uses experimental investigation and theoretical derivation to study the unified failure mechanism and ultimate capacity model of reinforced concrete (RC) members under combined axial, bending, shear and torsion loading. Fifteen RC members are tested under different combinations of compressive axial force, bending, shear and torsion using experimental equipment designed by the authors. The failure mechanism and ultimate strength data for the four groups of tested RC members under different combined loading conditions are investigated and discussed in detail. The experimental research seeks to determine how the ultimate strength of RC members changes with changing combined loads. According to the experimental research, a unified theoretical model is established by determining the shape of the warped failure surface, assuming an appropriate stress distribution on the failure surface, and considering the equilibrium conditions. This unified failure model can be reasonably and systematically changed into well-known failure theories of concrete members under single or combined loading. The unified calculation model could be easily used in design applications with some assumptions and simplifications. Finally, the accuracy of this theoretical unified model is verified by comparisons with experimental results. PMID:28414777
A visual graphic/haptic rendering model for hysteroscopic procedures.
Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer
2006-03-01
Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilises an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organised curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynaecologic endoscopy training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopy factors, current training and accreditation, and proposes a hysteroscopic simulator design that is suitable for educating and training.
The stability of cassette walls in compression
NASA Astrophysics Data System (ADS)
Voutay, Pierre-Arnaud
Much research into the behaviour of cold formed steel columns in the last decade has focused on channel sections undergoing local, distortional and overall buckling. Light gauge steel cassette sections are a particular form of channel section which offers an alternative form of load-bearing wall assembly for use in low-rise steel framed construction. Cassette wall sections possess wide and slender flanges so that, by including intermediate stiffeners in these wide flanges, a significant increase in the ultimate load capacity may be achieved. However, the introduction of intermediate stiffeners also increases the number of buckling modes (stiffener buckling) and, therefore complicates the behaviour and increases the risk of interactive buckling between these modes. The work undertaken in this thesis aims to clarify the behaviour of wide flanges in compression with and without intermediate stiffeners. In this research, the distortional mode of web and narrow flange buckling was inhibited by connecting the narrow flanges of the cassettes together at suitable intervals. "Generalised Beam Theory" (GBT), which allows the individual buckling modes to be considered individually and in predetermined combinations, provides a particularly good tool with which to analyse and understand the buckling behaviour of cassette sections with and without intermediate stiffeners. "Generalised Beam Theory" (GBT) is used throughout this work to determine the elastic buckling stress of the sections studied (simply supported stiffened plates, as well as cassette sections). Since the economic design of cold-formed steel sections requires the consideration of post- buckling behaviour, elastic buckling values are not directly comparable with design code values which are usually based on the concept of effective width. Therefore, finite element analysis with both material and geometric nonlinearity has also been carried out in order to obtain the ultimate strength in the critical mode or mode combination. Firstly the results of experimental test are analysed and their behaviour reproduced numerically. This serves to explain the test results and verify the numerical model. Confidence in modelling non-linear instability phenomena with the finite element method is acquired. Secondly, an initial parametric study was undertaken on the behaviour of cassette sections with and without intermediate stiffeners. This study considers the effect of the length and overall buckling on the behaviour of cassette sections, the effect of load eccentricity and the effect of the rotational restraint given by the web to the stiffened wide flange. A second parametric study including 96 specimens was undertaken next. This study considered the effect of the number (up to three intermediate stiffeners) and sizes of intermediate stiffeners on slender flanges with a slenderness ratio between 150 ≤ w/t ≤ 600. A wide range of geometries was studied covering single and interactive buckling modes. Comparison of the ultimate strength obtained from finite element analysis with the ultimate strength obtained using the effective width approach of modem design codes such as Eurocode 3 part 1.3 (1996) and NAS (North American specification (2001)) was then possible. By integrating the stress distribution over the length of the specimen, the stiffened wide flange can be isolated from the rest of the section (webs and narrow flanges). Design procedures tor plate elements incorporating one or two intermediate stiffeners under compressive load are given in Eurocode 3; Part 1.3. However, cassette sections, which have wider and more slender flanges than typical sheeting and decking, are increasingly being used in practical construction. For such cases, the design procedures in Eurocode 3 are less well founded. An improvement of the Eurocode 3 procedure dealing with intermediate stiffeners is proposed and validated for one, two or three stiffeners. Throughout the work, simple expressions suitable for design calculations are presented. Modern design codes as well as Direct Strength Method are evaluated in the light of findings of this work and wherever possible suggestions for improvements are made.
1981-06-01
normality and several types of nonnormality. Overall the rank transformation procedure seems to be the best. The Fisher’s LSD multiple comparisons procedure...the rank transformation procedure appears to maintain power better than Fisher’s LSD or the randomization proce- dures. The conclusion of this study...best. The Fisher’s LSD multiple comparisons procedure in the one way and two way layouts iv compared with a randomization procedure and with the same
Code of Federal Regulations, 2010 CFR
2010-04-01
... the several articles described in the annexed entry are, to the best of my knowledge and belief, the..., examination, or experimentation; that they are being returned without having been changed in condition in any manner, except by reason of their bona fide use as follows: (Describe change in condition) (Ultimate...
Adopting Cut Scores: Post-Standard-Setting Panel Considerations for Decision Makers
ERIC Educational Resources Information Center
Geisinger, Kurt F.; McCormick, Carina M.
2010-01-01
Standard-setting studies utilizing procedures such as the Bookmark or Angoff methods are just one component of the complete standard-setting process. Decision makers ultimately must determine what they believe to be the most appropriate standard or cut score to use, employing the input of the standard-setting panelists as one piece of information…
ERIC Educational Resources Information Center
Sutton, Lawrence R.; Hughes, Tammy L.; Huang, Ann; Lehman, Cathryn; Paserba, David; Talkington, Vanessa; Taormina, Rochelle; Walters, Jessie B.; Fenclau, Eric; Marshall, Stephanie
2013-01-01
Using the criteria established by the Commonwealth of Pennsylvania, the assessment procedures for establishing an autism spectrum disorder (ASD) in a previously undiagnosed adjudicated group is detailed. We examined 37 male adolescents adjudicated delinquent for sexual offenses who were sentenced to treatment. Ultimately, 22 (60%) were found to…
A SAS(®) macro implementation of a multiple comparison post hoc test for a Kruskal-Wallis analysis.
Elliott, Alan C; Hynan, Linda S
2011-04-01
The Kruskal-Wallis (KW) nonparametric analysis of variance is often used instead of a standard one-way ANOVA when data are from a suspected non-normal population. The KW omnibus procedure tests for some differences between groups, but provides no specific post hoc pair wise comparisons. This paper provides a SAS(®) macro implementation of a multiple comparison test based on significant Kruskal-Wallis results from the SAS NPAR1WAY procedure. The implementation is designed for up to 20 groups at a user-specified alpha significance level. A Monte-Carlo simulation compared this nonparametric procedure to commonly used parametric multiple comparison tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Applications of remote sensing, volume 3
NASA Technical Reports Server (NTRS)
Landgrebe, D. A. (Principal Investigator)
1977-01-01
The author has identified the following significant results. Of the four change detection techniques (post classification comparison, delta data, spectral/temporal, and layered spectral temporal), the post classification comparison was selected for further development. This was based upon test performances of the four change detection method, straightforwardness of the procedures, and the output products desired. A standardized modified, supervised classification procedure for analyzing the Texas coastal zone data was compiled. This procedure was developed in order that all quadrangles in the study are would be classified using similar analysis techniques to allow for meaningful comparisons and evaluations of the classifications.
Model-based local density sharpening of cryo-EM maps
Jakobi, Arjen J; Wilmanns, Matthias
2017-01-01
Atomic models based on high-resolution density maps are the ultimate result of the cryo-EM structure determination process. Here, we introduce a general procedure for local sharpening of cryo-EM density maps based on prior knowledge of an atomic reference structure. The procedure optimizes contrast of cryo-EM densities by amplitude scaling against the radially averaged local falloff estimated from a windowed reference model. By testing the procedure using six cryo-EM structures of TRPV1, β-galactosidase, γ-secretase, ribosome-EF-Tu complex, 20S proteasome and RNA polymerase III, we illustrate how local sharpening can increase interpretability of density maps in particular in cases of resolution variation and facilitates model building and atomic model refinement. PMID:29058676
Hugenschmidt, Gabriel; Hadorn, Ruedi; Scheeder, Martin R L; Silacci, Paolo; Scherrer, Daniel; Wenk, Caspar
2010-08-01
Effects of early (1h p.m. and 3h p.m.) and ultimate pH (24h p.m.) on level and amount of destructured zones in cooked cured hams were evaluated. In experiment 1, electrically stimulated (50 V, 14 Hz, 2 x 90s) and non-stimulated carcass halves, both in combination with two cooling procedures (2 degrees C from 30 min p.m. vs. 120 min p.m.) resulted in 1.5-35.2g/kg destructured zones in silversides and 58.4-120.0 g/kg destructured zones in topsides. A high temperature 1h p.m. in silversides (P=0.067) and topsides (P=0.054) was identified as the most important predictor for the defect. In experiment 2, cooked cured hams from topsides selected according to ultimate pH groups (pH<5.5, pH 5.5-5.7, pH>5.7) showed between 12.3 and 61.8 g/kg destructured zones. Ultimate pH was specified as most important, however, statistically still not significant (P=0.135) predictor for the defect. Chemical analysis resulted in low crude ash and high dry matter content as being characteristic for the defect. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Analysis of Nonvolatile Residue (NVR) from Spacecraft Systems
NASA Technical Reports Server (NTRS)
Colony, J. A.
1985-01-01
Organic contamination on critical spacecraft surfaces can cause electronic problems, serious attenuation of various optical signals, thermal control changes, and adhesion problems. Such contaminants can be detected early by the controlled use of witness mirrors, witness plates, wipe sampling, or direct solvent extraction. Each method requires careful control of variables of technique and materials to attain the ultimate sensitivities inherent to that procedure. Subsequent chemical analysis of the contaminant sample by infrared and mass spectrometry identifies the components, gives semiquantitative estimates of contaminant thickness, indicates possible sources of the nonvolatile residue (NVR), and provides guidance for effective cleanup procedures.
ERIC Educational Resources Information Center
Horowitz, Laura; Jansson, Liselotte; Ljungberg, Tomas; Hedenbro, Monica
2005-01-01
Background: Children with language impairment (LI) experience social difficulties, including conflict management. This paper is therefore motivated to examine behavioural processes guiding preschool peer conflict progression, which ultimately contributes to overall development. Aims: To describe behavioural sequences in conflicts between children…
A Comparison of Evaluation Practices Based on E-Learning and Mobile Learning Delivery Rates
ERIC Educational Resources Information Center
Marshall, James
2018-01-01
Learning and performance professionals are increasingly pressed to measure the results of their learning program design efforts, and ultimately prove their worth. However, evaluation efforts are often limited to measuring participant reaction. This study sought to quantify evaluation practices in organizations and investigate how the use of…
A Comparison of Associate and Bachelor Degree Nursing Students' Motivation
ERIC Educational Resources Information Center
Parlett, Deborah K.
2012-01-01
Student motivation is a key factor in determining whether college students are successful in their academic careers and, ultimately their professional careers. Motivation is an internal drive within a person to move to action to complete a task. Student motivation encompasses self-regulation, determination, and efficacy. It is important for…
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.
2001-01-01
This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.
NASA Technical Reports Server (NTRS)
Steen, Laura E.; Ide, Robert F.; Van Zante, Judith F.
2016-01-01
The Icing Research Tunnel at NASA Glenn has recently switched from using the Icing Blade to using the SEA Multi-Element Sensor (also known as the multi-wire) for its calibration of cloud liquid water content. In order to peform this transition, tests were completed to compare the Multi-Element Sensor to the Icing Blade, particularly with respect to liquid water content, airspeed, and drop size. The two instruments were found to compare well for the majority of Appendix C conditions. However, it was discovered that the Icing Blade under-measures when the conditions approach the Ludlam Limit. This paper also describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, mounting underneath a splitter plate, and correcting for a jump in the compensation wire power. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor, health-monitoring checks for the instrument, and a sensing-element configuration comparison. Ultimately these tests showed that in the IRT, the multi-wire is a better instrument for measuring cloud liquid water content than the blade.
Auch, Alexander F; Klenk, Hans-Peter; Göker, Markus
2010-01-28
DNA-DNA hybridization (DDH) is a widely applied wet-lab technique to obtain an estimate of the overall similarity between the genomes of two organisms. To base the species concept for prokaryotes ultimately on DDH was chosen by microbiologists as a pragmatic approach for deciding about the recognition of novel species, but also allowed a relatively high degree of standardization compared to other areas of taxonomy. However, DDH is tedious and error-prone and first and foremost cannot be used to incrementally establish a comparative database. Recent studies have shown that in-silico methods for the comparison of genome sequences can be used to replace DDH. Considering the ongoing rapid technological progress of sequencing methods, genome-based prokaryote taxonomy is coming into reach. However, calculating distances between genomes is dependent on multiple choices for software and program settings. We here provide an overview over the modifications that can be applied to distance methods based in high-scoring segment pairs (HSPs) or maximally unique matches (MUMs) and that need to be documented. General recommendations on determining HSPs using BLAST or other algorithms are also provided. As a reference implementation, we introduce the GGDC web server (http://ggdc.gbdp.org).
Code of Federal Regulations, 2014 CFR
2014-04-01
... apply; (D) As part of the internal risk management control system for the affiliate group, establish... risk management control system for the affiliate group that the ultimate holding company has... reports or to modify its group-wide internal risk management control procedures. If the Commission finds...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Commission determines, based on a review of the group-wide internal risk management control system and... regulator, all written policies and procedures concerning the group-wide internal risk management control... (as defined in 12 CFR 225, appendix A); (ii) Cumulative and non-cumulative preferred stock, except...
Code of Federal Regulations, 2010 CFR
2010-04-01
... Commission determines, based on a review of the group-wide internal risk management control system and... regulator, all written policies and procedures concerning the group-wide internal risk management control... (as defined in 12 CFR 225, appendix A); (ii) Cumulative and non-cumulative preferred stock, except...
Design of advanced beams considering elasto-plastic behaviour of material
NASA Astrophysics Data System (ADS)
Tolun, S.
1992-10-01
The paper proposes a computational procedure for precise calculation of limit and ultimate or design loads, which must be carried by an advanced aviation beam, without permanent distortion and without rupture. Among several stress-strain curve representations, one that is suitable for a particular material is chosen for applied loads, yield, and failure load calculations, and then nonlinear analysis is performed.
Hysteroscopic simulator for training and educational purposes.
Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer
2006-01-01
Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilizes an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organized curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynecological endoscopic training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopic factors as well as current training and accreditation norms, and proposes a hysteroscopic simulator design that is suitable for educating and training.
Impact of gastrectomy procedural complexity on surgical outcomes and hospital comparisons.
Mohanty, Sanjay; Paruch, Jennifer; Bilimoria, Karl Y; Cohen, Mark; Strong, Vivian E; Weber, Sharon M
2015-08-01
Most risk adjustment approaches adjust for patient comorbidities and the primary procedure. However, procedures done at the same time as the index case may increase operative risk and merit inclusion in adjustment models for fair hospital comparisons. Our objectives were to evaluate the impact of surgical complexity on postoperative outcomes and hospital comparisons in gastric cancer surgery. Patients who underwent gastric resection for cancer were identified from a large clinical dataset. Procedure complexity was characterized using secondary procedure CPT codes and work relative value units (RVUs). Regression models were developed to evaluate the association between complexity variables and outcomes. The impact of complexity adjustment on model performance and hospital comparisons was examined. Among 3,467 patients who underwent gastrectomy for adenocarcinoma, 2,171 operations were distal and 1,296 total. A secondary procedure was reported for 33% of distal gastrectomies and 59% of total gastrectomies. Six of 10 secondary procedures were associated with adverse outcomes. For example, patients who underwent a synchronous bowel resection had a higher risk of mortality (odds ratio [OR], 2.14; 95% CI, 1.07-4.29) and reoperation (OR, 2.09; 95% CI, 1.26-3.47). Model performance was slightly better for nearly all outcomes with complexity adjustment (mortality c-statistics: standard model, 0.853; secondary procedure model, 0.858; RVU model, 0.855). Hospital ranking did not change substantially after complexity adjustment. Surgical complexity variables are associated with adverse outcomes in gastrectomy, but complexity adjustment does not affect hospital rankings appreciably. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ronold, K.O.; Nielsen, N.J.R.; Tura, F.
This paper demonstrates how a structural reliability method can be applied as a rational means to analyze free spans of submarine pipelines with respect to failure in ultimate loading, and to establish partial safety factors for design of such free spans against this failure mode. It is important to note that the described procedure shall be considered as an illustration of a structural reliability methodology, and that the results do not represent a set of final design recommendations. A scope of design cases, consisting of a number of available site-specific pipeline spans, is established and is assumed representative for themore » future occurrence of submarine pipeline spans. Probabilistic models for the wave and current loading and its transfer to stresses in the pipe wall of a pipeline span is established together with a stochastic representation of the material resistance. The event of failure in ultimate loading is considered as based on a limit state which is reached when the maximum stress over the design life of the pipeline exceeds the yield strength of the pipe material. The yielding limit state is considered an ultimate limit state (ULS).« less
Sepsis and multiorgan failure following TVT procedure.
Stec, Piotr; Connell, Rowan
2014-04-01
Tension-free vaginal tape (TVT), is a commonly performed, low risk procedure for treatment of stress urinary incontinence (SUI). Severe complications are rare, but can be potentially life threatening. We present a case of 66 year old patient who sustained bladder perforation at the time of TVT procedure and subsequently developed sepsis rapidly leading to multi-organ failure and triggering sequence of serious complications. During her inpatient stay she required ITU admission, emergency laparotomy, TVT mesh removal, bowel resection due to ischemic colitis and anticoagulation for pulmonary embolism. Despite of clinical picture of sepsis her microbiology tests were almost consistently negative. This case emphasise importance of awareness and quick recognition of TVT related complications. Patient ultimately survived and recovered thanks to timely and coordinated management by the multidisciplinary team of doctors.
Health hazards associated with solid waste disposal.
Gaby, W L
1981-01-01
The landfilling and disposal of domestic solid waste should be considered as great or greater a public health hazard as raw sewage. Solid waste is toxic and contains a greater variety of pathogenic microorganisms than does sewage sludge. Of all the procedures for solid waste disposal, landfills have and will continue to give rise to serious public health problems of land and water pollution. Although the general public is opposed to landfilling our inept health officials have offered small communities and cities no choice. Small communities do not have the technical knowledge or the funds to initiate alternative procedures. As the volume of solid waste increases each year the magnitude of the health hazards will eventually force public health agencies to implement correct disposal procedures ultimately resulting in recycling.
Laparoscopic intestinal derotation: original technique.
Valle, Mario; Federici, Orietta; Tarantino, Enrico; Corona, Francesco; Garofalo, Alfredo
2009-06-01
The intestinal derotation technique, introduced by Cattel and Valdoni 40 years ago, is carried out using a laparoscopic procedure, which is described here for the first time. The method is effective in the treatment of malign lesions of the III and IV duodenum and during laparoscopic subtotal colectomy with anastomosis between the ascending colon and the rectum. Ultimately, the procedure allows for the verticalization of the duodenal C and the anterior positioning of the mesenteric vessels, facilitating biopsy and resection of the III and IV duodenal portions and allowing anastomosis of the ascending rectum, avoiding both subtotal colectomy and the risk of torsion of the right colic loop. Although the procedure calls for extensive experience with advanced video-laparoscopic surgery, it is both feasible and repeatable. In our experience we have observed no mortality or morbidity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anikovsky, V.V.; Karzov, G.P.; Timofeev, B.T.
The paper demonstrates an insufficiency of some requirements native Norms (when comparing them with the foreign requirements for the consideration of calculating situations): (1) leak before break (LBB); (2) short cracks; (3) preliminary loading (warm prestressing). In particular, the paper presents (1) Comparison of native and foreign normative requirements (PNAE G-7-002-86, Code ASME, BS 1515, KTA) on permissible stress levels and specifically on the estimation of crack initiation and propagation; (2) comparison of RF and USA Norms of pressure vessel material acceptance and also data of pressure vessel hydrotests; (3) comparison of Norms on the presence of defects (RF andmore » USA) in NPP vessels, developments of defect schematization rules; foundation of a calculated defect (semi-axis correlation a/b) for pressure vessel and piping components: (4) sequence of defect estimation (growth of initial defects and critical crack sizes) proceeding from the concept LBB; (5) analysis of crack initiation and propagation conditions according to the acting Norms (including crack jumps); (6) necessity to correct estimation methods of ultimate states of brittle an ductile fracture and elastic-plastic region as applied to calculating situation: (a) LBB and (b) short cracks; (7) necessity to correct estimation methods of ultimate states with the consideration of static and cyclic loading (warm prestressing effect) of pressure vessel; estimation of the effect stability; (8) proposals on PNAE G-7-002-86 Norm corrections.« less
NASA Astrophysics Data System (ADS)
Gholamhoseini, Alireza
2018-03-01
Composite one-way concrete slabs with profiled steel decking as permanent formwork are commonly used in the construction industry. The steel decking supports the wet concrete of a cast in situ reinforced or post-tensioned concrete slab and, after the concrete sets, acts as external reinforcement. In this type of slab, longitudinal shear failure between the concrete and the steel decking is the most common type of failure at the ultimate load stage. Design codes require the experimental evaluation of the ultimate load capacity and longitudinal shear strength of each type of steel decking using full-scale tests on simple-span slabs. There is also no procedure in current design codes to evaluate the ultimate load capacity and longitudinal shear strength of continuous composite slabs and this is often assessed experimentally by full-scale tests. This paper presents the results of three full-scale tests up to failure on continuous composite concrete slabs cast with trapezoidal steel decking profile (KF70) that is widely used in Australia. Slab specimens were tested in four-point bending at each span with shear spans of span/4. The longitudinal shear failure of each slab is evaluated and the measured mid-span deflection, the end slip and the mid-span steel and concrete strains are also presented and discussed. Redistribution of bending moment in each slab is presented and discussed. A finite element model is proposed and verified by experimental data using interface element to model the bond properties between steel decking and concrete slab and investigate the ultimate strength of continuous composite concrete slabs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, John R.; Brooks, Dusty Marie
In pressurized water reactors, the prevention, detection, and repair of cracks within dissimilar metal welds is essential to ensure proper plant functionality and safety. Weld residual stresses, which are difficult to model and cannot be directly measured, contribute to the formation and growth of cracks due to primary water stress corrosion cracking. Additionally, the uncertainty in weld residual stress measurements and modeling predictions is not well understood, further complicating the prediction of crack evolution. The purpose of this document is to develop methodology to quantify the uncertainty associated with weld residual stress that can be applied to modeling predictions andmore » experimental measurements. Ultimately, the results can be used to assess the current state of uncertainty and to build confidence in both modeling and experimental procedures. The methodology consists of statistically modeling the variation in the weld residual stress profiles using functional data analysis techniques. Uncertainty is quantified using statistical bounds (e.g. confidence and tolerance bounds) constructed with a semi-parametric bootstrap procedure. Such bounds describe the range in which quantities of interest, such as means, are expected to lie as evidenced by the data. The methodology is extended to provide direct comparisons between experimental measurements and modeling predictions by constructing statistical confidence bounds for the average difference between the two quantities. The statistical bounds on the average difference can be used to assess the level of agreement between measurements and predictions. The methodology is applied to experimental measurements of residual stress obtained using two strain relief measurement methods and predictions from seven finite element models developed by different organizations during a round robin study.« less
Comparing solar energy alternatives
NASA Astrophysics Data System (ADS)
White, J. R.
1984-03-01
This paper outlines a computational procedure for comparing the merits of alternative processes to convert solar radiation to heat, electrical power, or chemical energy. The procedure uses the ratio of equipment investment to useful work as an index. Comparisons with conversion counterparts based on conventional fuels are also facilitated by examining this index. The procedure is illustrated by comparisons of (1) photovoltaic converters of differing efficiencies; (2) photovoltaic converters with and without focusing concentrators; (3) photovoltaic conversion plus electrolysis vs photocatalysis for the production of hydrogen; (4) photovoltaic conversion plus plasma arcs vs photocatalysis for nitrogen fixation. Estimates for conventionally-fuelled processes are included for comparison. The reasons why solar-based concepts fare poorly in such comparisons are traced to the low energy density of solar radiation and its low stream time factor resulting from the limited number of daylight hours available and clouds obscuring the sun.
A/R systems reduce delayed and denied reimbursements.
Escobar, Carlos
2007-01-01
The day-to-day benefits of a comprehensive billing and collections system are pro-active and preventive--administrators are increasingly learning that accelerating billings hastens collections and, ultimately, facility profitability. Effective billing and collections management services work closely with the facility, matching nightly "dumps" of patient files with transcripts. This marriage of otherwise disparate data creates a billing unit that reduces errors and ensures no billable procedures are lost. Ultimately, the goal of any medical practice that engages an ASP application or outsource solution is not to sit idly by while allowing a billing company to take control of a practice's revenue stream. The ability to track the billing process from transcript submission to payment provides a facility with all information necessary to manage cash flow, revenues, and even personal and practice financial planning.
On the ultimate uncertainty of the top quark pole mass
NASA Astrophysics Data System (ADS)
Beneke, M.; Marquard, P.; Nason, P.; Steinhauser, M.
2017-12-01
We combine the known asymptotic behaviour of the QCD perturbation series expansion, which relates the pole mass of a heavy quark to the MS ‾ mass, with the exact series coefficients up to the four-loop order to determine the ultimate uncertainty of the top-quark pole mass due to the renormalon divergence. We perform extensive tests of our procedure by varying the number of colours and flavours, as well as the scale of the strong coupling and the MS ‾ mass. Including an estimate of the internal bottom and charm quark mass effect, we conclude that this uncertainty is around 110 MeV. We further estimate the additional contribution to the mass relation from the five-loop correction and beyond to be around 300 MeV.
Turbulent Extreme Event Simulations for Lidar-Assisted Wind Turbine Control
NASA Astrophysics Data System (ADS)
Schlipf, David; Raach, Steffen
2016-09-01
This work presents a wind field generator which allows to shape wind fields in the time domain while maintaining the spectral properties. This is done by an iterative generation of wind fields and by minimizing the error between wind characteristics of the generated wind fields and desired values. The method leads towards realistic ultimate load calculations for lidar-assisted control. This is demonstrated by fitting a turbulent wind field to an Extreme Operating Gust. The wind field is then used to compare a baseline feedback controller alone against a combined feedback and feedforward controller using simulated lidar measurements. The comparison confirms that the lidar-assisted controller is still able to significantly reduce the ultimate loads on the tower base under this more realistic conditions.
USDA-ARS?s Scientific Manuscript database
Water management should be the foundation of container nursery production as it is linked directly to both water and nutrient uptake efficiency and ultimately, environmental impact. In this study gravimetric water management technique was used by means of load cell/computer interface to determine i...
Lorentz-invariant formulation of Cherenkov radiation by tachyons
NASA Technical Reports Server (NTRS)
Jones, F. C.
1972-01-01
Previous treatments of Cherenkov radiation, electromagnetic and gravitational, by tachyons were in error because the prescription employed to cut off the divergent integral over frequency is not a Lorentz invariant procedure. The resulting equation of motion for the tachyon is therefore not covariant. The proper procedure requires an extended, deformable distribution of charge or mass and yields a particularly simple form for the tachyon's world line, one that could be deduced from simple invariance considerations. It is shown that Cherenkov radiation by tachyons implys their ultimate annihilation with an antitachyon and demonstrates a disturbing property of tachyons, namely the impossibility of specifying arbitrary Cauchy data even in a purely classical theory.
Micro-telerobotic applications for microsurgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ford, W.E.; Morimoto, A.K.; Kozlowski, D.M.
MicroDexterity Systems Inc. and Sandia National Laboratories are collaborating on the design of a six degree-of-freedom surgeon-controlled micropositioner and a six degree-of-freedom surgeon-controlled master for use in microsurgery. A control system will provide the linkage between the force-reflecting master and micropositioner for force scaling, position scaling, and tremor filtering. The technologies developed by this project are expected to enhance the skills of surgeons, improve the success rates for existing microsurgical procedures, make new high-dexterity procedures possible, and ultimately reduce surgical costs by increasing the precision and speed of operations. This paper discusses the motivation, approach, and accomplishments to date.
Heath, Garvin A; O'Donoughue, Patrick; Arent, Douglas J; Bazilian, Morgan
2014-08-05
Recent technological advances in the recovery of unconventional natural gas, particularly shale gas, have served to dramatically increase domestic production and reserve estimates for the United States and internationally. This trend has led to lowered prices and increased scrutiny on production practices. Questions have been raised as to how greenhouse gas (GHG) emissions from the life cycle of shale gas production and use compares with that of conventionally produced natural gas or other fuel sources such as coal. Recent literature has come to different conclusions on this point, largely due to differing assumptions, comparison baselines, and system boundaries. Through a meta-analytical procedure we call harmonization, we develop robust, analytically consistent, and updated comparisons of estimates of life cycle GHG emissions for electricity produced from shale gas, conventionally produced natural gas, and coal. On a per-unit electrical output basis, harmonization reveals that median estimates of GHG emissions from shale gas-generated electricity are similar to those for conventional natural gas, with both approximately half that of the central tendency of coal. Sensitivity analysis on the harmonized estimates indicates that assumptions regarding liquids unloading and estimated ultimate recovery (EUR) of wells have the greatest influence on life cycle GHG emissions, whereby shale gas life cycle GHG emissions could approach the range of best-performing coal-fired generation under certain scenarios. Despite clarification of published estimates through harmonization, these initial assessments should be confirmed through methane emissions measurements at components and in the atmosphere and through better characterization of EUR and practices.
Heath, Garvin A.; O’Donoughue, Patrick; Arent, Douglas J.; Bazilian, Morgan
2014-01-01
Recent technological advances in the recovery of unconventional natural gas, particularly shale gas, have served to dramatically increase domestic production and reserve estimates for the United States and internationally. This trend has led to lowered prices and increased scrutiny on production practices. Questions have been raised as to how greenhouse gas (GHG) emissions from the life cycle of shale gas production and use compares with that of conventionally produced natural gas or other fuel sources such as coal. Recent literature has come to different conclusions on this point, largely due to differing assumptions, comparison baselines, and system boundaries. Through a meta-analytical procedure we call harmonization, we develop robust, analytically consistent, and updated comparisons of estimates of life cycle GHG emissions for electricity produced from shale gas, conventionally produced natural gas, and coal. On a per-unit electrical output basis, harmonization reveals that median estimates of GHG emissions from shale gas-generated electricity are similar to those for conventional natural gas, with both approximately half that of the central tendency of coal. Sensitivity analysis on the harmonized estimates indicates that assumptions regarding liquids unloading and estimated ultimate recovery (EUR) of wells have the greatest influence on life cycle GHG emissions, whereby shale gas life cycle GHG emissions could approach the range of best-performing coal-fired generation under certain scenarios. Despite clarification of published estimates through harmonization, these initial assessments should be confirmed through methane emissions measurements at components and in the atmosphere and through better characterization of EUR and practices. PMID:25049378
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landis, E.R.; Rohrbacher, T.J.; Gluskoter, H.
1999-07-01
As part of the activities conducted under the U.S. Hungarian Science and Technology Fund, a total of 39 samples from five coal mines in Hungary were selected for standard coal analyses and major, minor and trace elements analysis. The mine areas sampled were selected to provide a spectrum of coal quality information for comparison with other coal areas in central Europe and worldwide. All of the areas are of major importance in the energy budget of Hungary. The five sample sites contain coal in rocks of Jurassic, Cretaceous, Eocene, Miocene, and Pliocene age. The coals, from four underground and onemore » surface mine, range in rank from high volatile bituminous to lignite B. Most of the coal produced from the mines sampled is used to generate electricity. Some of the power plants that utilize the coals also provide heat for domestic and process usage. The standard coal analysis program is based on tests performed in accordance with standards of the American Society for Testing and Materials (ASTM). Proximate and ultimate analyses were supplemented by determinations of the heating value, equilibrium moisture, forms of sulfur, free-swelling index, ash fusion temperatures (both reducing and oxidizing), apparent specific gravity and Hardgrove Grindability index. The major, minor and trace element analyses were performed in accordance with standardized procedures of the U.S. Geological Survey. The analytical results will be available in the International Coal Quality Data Base of the USGS. The results of the program provide data for comparison with test data from Europe and information of value to potential investors or cooperators in the coal industry of Hungary and Central Europe.« less
Lehmann, R; Gallert, C; Roddelkopf, T; Junginger, S; Wree, A; Thurow, K
2016-08-01
Cancer diseases are a common problem of the population caused by age and increased harmful environmental influences. Herein, new therapeutic strategies and compound screenings are necessary. The regular 2D cultivation has to be replaced by three dimensional cell culturing (3D) for better simulation of in vivo conditions. The 3D cultivation with alginate matrix is an appropriate method for encapsulate cells to form cancer constructs. The automated manufacturing of alginate beads might be an ultimate method for large-scaled manufacturing constructs similar to cancer tissue. The aim of this study was the integration of full automated systems for the production, cultivation and screening of 3D cell cultures. We compared the automated methods with the regular manual processes. Furthermore, we investigated the influence of antibiotics on these 3D cell culture systems. The alginate beads were formed by automated and manual procedures. The automated steps were processes by the Biomek(®) Cell Workstation (celisca, Rostock, Germany). The proliferation and toxicity were manually and automatically evaluated at day 14 and 35 of cultivation. The results visualized an accumulation and expansion of cell aggregates over the period of incubation. However, the proliferation and toxicity were faintly and partly significantly decreased on day 35 compared to day 14. The comparison of the manual and automated methods displayed similar results. We conclude that the manual production process could be replaced by the automation. Using automation, 3D cell cultures can be produced in industrial scale and improve the drug development and screening to treat serious illnesses like cancer.
Teshome, Million; Wolde, Zenebe; Gedefaw, Abel; Tariku, Mequanent; Asefa, Anteneh
2018-05-24
Surgical Informed Consent (SIC) has long been recognized as an important component of modern medicine. The ultimate goals of SIC are to improve clients' understanding of the intended procedure, increase client satisfaction, maintain trust between clients and health providers, and ultimately minimize litigation issues related to surgical procedures. The purpose of the current study is to assess the comprehensiveness of the SIC process for women undergoing obstetric and gynecologic surgeries. A hospital-based cross-sectional study was undertaken at Hawassa University Comprehensive Specialized Hospital (HUCSH) in November and December, 2016. A total of 230 women who underwent obstetric and/or gynecologic surgeries were interviewed immediately after their hospital discharge to assess their experience of the SIC process. Thirteen components of SIC were used based on international recommendations, including the Royal College of Surgeon's standards of informed consent practices for surgical procedures. Descriptive summaries are presented in tables and figures. Forty percent of respondents were aged between 25 and 29 years. Nearly a quarter (22.6%) had no formal education. More than half (54.3%) of respondents had undergone an emergency surgical procedure. Only 18.4% of respondents reported that the surgeon performing the operation had offered SIC, while 36.6% of respondents could not recall who had offered SIC. All except one respondent provided written consent to undergo a surgical procedure. However, 8.3% of respondents received SIC service while already on the operation table for their procedure. Only 73.9% of respondents were informed about the availability (or lack thereof) of alternative treatment options. Additionally, a majority of respondents were not informed about the type of anesthesia to be used (88.3%) and related complications (87.4%). Only 54.2% of respondents reported that they had been offered at least six of the 13 SIC components used by the investigators. There is gap in the provision of comprehensive and standardized pre-operative counseling for obstetric and gynecologic surgeries in the study hospital. This has a detrimental effect on the overall quality of care clients receive, specifically in terms of client expectations and information needs.
ERIC Educational Resources Information Center
Ng, Daniel; Supaporn, Potibut
A study investigated the trend of current U.S. television commercial informativeness by comparing the results with Alan Resnik and Bruce Stern's previous benchmark study conducted in 1977. A systematic random sampling procedure was used to select viewing dates and times of commercials from the three national networks. Ultimately, a total of 550…
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2012 CFR
2012-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
ERIC Educational Resources Information Center
JENSEN, ARTHUR K.
THE INVESTIGATION RESULTED IN THE PRODUCTION OF 88 LOW-COST OVERHEAD PROJECTION TRANSPARENCIES ON THE BASIC PRINCIPLES OF POWER TRANSMISSION IN AGRICULTURAL MACHINERY. DEVELOPING TECHNIQUES FOR OFFSET PRINTING ON PLASTIC REQUIRED OVERCOMING PROBLEMS OF STATIC ELECTRICITY, INK ADHESION, OFFSETTING, AND DRYING. MACHINERY, ENVIRONMENT, AND INK WERE…
Gain scheduling - Potential hazards and possible remedies
NASA Technical Reports Server (NTRS)
Shamma, Jeff S.; Athans, Michael
1991-01-01
A common gain scheduling rule-of-thumb is to schedule on a slow variable. In this work, it is shown how current gain scheduling practice is necessarily limited to slow variations in the scheduling variable. These limitations are revealed to be consequences of fundamental control concepts. Furthermore, it is shown how a formulation of the gain scheduling procedure can lead toward ultimately removing these restrictions.
NASA Astrophysics Data System (ADS)
Zingone, Adriana; Harrison, Paul J.; Kraberg, Alexandra; Lehtinen, Sirpa; McQuatters-Gollop, Abigail; O'Brien, Todd; Sun, Jun; Jakobsen, Hans H.
2015-09-01
Phytoplankton diversity and its variation over an extended time scale can provide answers to a wide range of questions relevant to societal needs. These include human health, the safe and sustained use of marine resources and the ecological status of the marine environment, including long-term changes under the impact of multiple stressors. The analysis of phytoplankton data collected at the same place over time, as well as the comparison among different sampling sites, provide key information for assessing environmental change, and evaluating new actions that must be made to reduce human induced pressures on the environment. To achieve these aims, phytoplankton data may be used several decades later by users that have not participated in their production, including automatic data retrieval and analysis. The methods used in phytoplankton species analysis vary widely among research and monitoring groups, while quality control procedures have not been implemented in most cases. Here we highlight some of the main differences in the sampling and analytical procedures applied to phytoplankton analysis and identify critical steps that are required to improve the quality and inter-comparability of data obtained at different sites and/or times. Harmonization of methods may not be a realistic goal, considering the wide range of purposes of phytoplankton time-series data collection. However, we propose that more consistent and detailed metadata and complementary information be recorded and made available along with phytoplankton time-series datasets, including description of the procedures and elements allowing for a quality control of the data. To keep up with the progress in taxonomic research, there is a need for continued training of taxonomists, and for supporting and complementing existing web resources, in order to allow a constant upgrade of knowledge in phytoplankton classification and identification. Efforts towards the improvement of metadata recording, data annotation and quality control procedures will ensure the internal consistency of phytoplankton time series and facilitate their comparability and accessibility, thus strongly increasing the value of the precious information they provide. Ultimately, the sharing of quality controlled data will allow one to recoup the high cost of obtaining the data through the multiple use of the time-series data in various projects over many decades.
The 100 cm solar telescope primary mirror study
NASA Technical Reports Server (NTRS)
1975-01-01
The manufacturing impact of primary mirror configuration on the performance of a 100 cm aperture solar telescope was studied. Three primary mirror configurations were considered: solid, standard lightweight, and mushroom. All of these are of low expansion material. Specifically, the study consisted of evaluating the mirrors with regard to: manufacturing metrology, manufacturing risk factors and ultimate quality assessment. As a result of this evaluation, a performance comparison of the configurations was made, and a recommendation of mirror configuration is the final output. These evaluations, comparisons and recommendations are discussed in detail. Other investigations were completed and are documented in the appendices.
Stanek, Agata; Cholewka, Armand; Gadula, Jolanta; Drzazga, Zofia; Sieron, Aleksander; Sieron-Stoltny, Karolina
2015-01-01
The present study investigated whether whole-body cryotherapy (WBC) procedures could potentially have more beneficial effects on index of BASDAI and BASFI, pain intensity, and spine mobility parameters: Ott test, modified Schober test, chest expansion in ankylosing spondylitis (AS) patients, than kinesiotherapy procedures used separately. AS patients were exposed to a cycle of WBC procedures lasting 3 minutes a day, with a subsequent 60 minutes of kinesiotherapy or 60 minutes of kinesiotherapy only, for 10 consecutive days excluding weekend. After the completion of the cycle of WBC procedures with subsequent kinesiotherapy in the AS patients, BASDAI index decreased about 40% in comparison with the input value, whereas in the group of patients who received only kinesiotherapy it decreased only about 15% in comparison with the input value. After the completion of the treatment in the WBC group, BASFI index decreased about 30% in comparison with the input value, whereas in the kinesiotherapy group it only decreased about 16% in comparison with the input value. The important conclusion was that, in WBC group with subsequent kinesiotherapy, we observed on average about twice better results than in the group treated only by kinesiotherapy.
Stanek, Agata; Cholewka, Armand; Gadula, Jolanta; Drzazga, Zofia; Sieron, Aleksander; Sieron-Stoltny, Karolina
2015-01-01
The present study investigated whether whole-body cryotherapy (WBC) procedures could potentially have more beneficial effects on index of BASDAI and BASFI, pain intensity, and spine mobility parameters: Ott test, modified Schober test, chest expansion in ankylosing spondylitis (AS) patients, than kinesiotherapy procedures used separately. AS patients were exposed to a cycle of WBC procedures lasting 3 minutes a day, with a subsequent 60 minutes of kinesiotherapy or 60 minutes of kinesiotherapy only, for 10 consecutive days excluding weekend. After the completion of the cycle of WBC procedures with subsequent kinesiotherapy in the AS patients, BASDAI index decreased about 40% in comparison with the input value, whereas in the group of patients who received only kinesiotherapy it decreased only about 15% in comparison with the input value. After the completion of the treatment in the WBC group, BASFI index decreased about 30% in comparison with the input value, whereas in the kinesiotherapy group it only decreased about 16% in comparison with the input value. The important conclusion was that, in WBC group with subsequent kinesiotherapy, we observed on average about twice better results than in the group treated only by kinesiotherapy. PMID:26273618
NASA Technical Reports Server (NTRS)
Predmore, Roamer; LeBoeuf, Claudia; Hovanec, Andrew
1997-01-01
In response to the elimination of production of several Ozone Depleting Chemicals (ODC's) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-free cleaning procedures. The short term leg of the philosophy was the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. The long-term leg of that philosophy was the initiation of a several tier testing program that will deliver increasing amounts of information over the next few years, starting with accelerated lubricant life tests that compare lubricant life on surfaces cleaned with ODC solvents with lubricant life on surfaces cleaned with ODC-free solvents. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years before a number of important tribological questions can be answered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life lubricated mechanism based on a number of parameters, including 4 comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODC's based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.
NASA Technical Reports Server (NTRS)
Smith, Jeffrey, S.; Aronstein, David L.; Dean, Bruce H.; Lyon, Richard G.
2012-01-01
The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.
On Two-Stage Multiple Comparison Procedures When There Are Unequal Sample Sizes in the First Stage.
ERIC Educational Resources Information Center
Wilcox, Rand R.
1984-01-01
Two stage multiple-comparison procedures give an exact solution to problems of power and Type I errors, but require equal sample sizes in the first stage. This paper suggests a method of evaluating the experimentwise Type I error probability when the first stage has unequal sample sizes. (Author/BW)
Pairwise Multiple Comparisons in Single Group Repeated Measures Analysis.
ERIC Educational Resources Information Center
Barcikowski, Robert S.; Elliott, Ronald S.
Research was conducted to provide educational researchers with a choice of pairwise multiple comparison procedures (P-MCPs) to use with single group repeated measures designs. The following were studied through two Monte Carlo (MC) simulations: (1) The T procedure of J. W. Tukey (1953); (2) a modification of Tukey's T (G. Keppel, 1973); (3) the…
A comparison of techniques for generating forest ownership spatial products
Brett J. Butler; Jaketon H. Hewes; Greg C. Liknes; Mark D. Nelson; Stephanie A. Snyder
2014-01-01
To fully understand forest resources, it is imperative to understand the social context in which the forests exist. A pivotal part of that context is the forest ownership. It is the owners, operating within biophysical and social constraints, who ultimately decide if the land will remain forested, how the resources will be used, and by whom. Forest ownership patterns...
ERIC Educational Resources Information Center
Couturier, Yves; Dumas-Laverdiere, Christian
2006-01-01
The reflections on interdisciplinarity cover several dimensions. One, among them, concerns the nature of what occurs between two disciplines. Does inter-disciplinarity relate to an intention, to a metatheory, to the object, or to a method? It is this ultimate space that we propose to study, supported by Reswebers (2000) proposition, putting the…
ERIC Educational Resources Information Center
Church, Olive D.
A study examined the feasibility of consulting-training as a career option for business professionals. Data were gathered from a mail survey completed by a total of 60 firms in Arizona and Colorado and also from interviews, the investigator's participation and collaboration experiences with consultants, and a comparison of the literature on…
Parent Report of Early Lexical Production in Bilingual Children: A Cross-Linguistic CDI Comparison
ERIC Educational Resources Information Center
O'Toole, Ciara; Gatt, Daniela; Hickey, Tina M.; Miekisz, Aneta; Haman, Ewa; Armon-Lotem, Sharon; Rinker, Tanja; Ohana, Odelya; dos Santos, Christophe; Kern, Sophie
2017-01-01
This paper compared the vocabulary size of a group of 250 bilinguals aged 24-36 months acquiring six different language pairs using an analogous tool, and attempted to identify factors that influence vocabulary sizes and ultimately place children at risk for language delay. Each research group used adaptations of the MacArthur-Bates Communicative…
Better vacuum by removal of diffusion-pump-oil contaminants
NASA Technical Reports Server (NTRS)
Buggele, A. E.
1975-01-01
The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.
NASA Astrophysics Data System (ADS)
Takeda, Minoru; Nara, Hiroyuki; Maekawa, Kazuma; Fujikawa, Shizuichi; Matsuno, Yu; Kuroda, Tsuneo; Kumakura, Hiroaki
Hydrogen is an ultimate energy source because only water is produced after the chemical reaction of hydrogen and oxygen. In the near future, a large amount of hydrogen, produced using sustainable/renewable energy, is expected to be consumed. Since liquid hydrogen (LH2) has the advantage of high storage efficiency, it is expected to be the ultimate medium for the worldwide storage and transportation of large amounts of hydrogen. To make a simulation model of the sloshing of LH2 inside a 2000 liter tank, simulation analyses of LH2 surface oscillation, temperature and pressure inside the tank during a truck transportation have been carried out using a multipurpose software ANSYS CFX. Numerical results are discussed in comparison with experimental results.
Accuracy Considerations in Image-guided Cardiac Interventions: Experience and Lessons Learned
Linte, Cristian A.; Lang, Pencilla; Rettmann, Maryam E.; Cho, Daniel S.; Holmes, David R.; Robb, Richard A.; Peters, Terry M.
2014-01-01
Motivation Medical imaging and its application in interventional guidance has revolutionized the development of minimally invasive surgical procedures leading to reduced patient trauma, fewer risks, and shorter recovery times. However, a frequently posed question with regards to an image guidance system is “how accurate is it?” On one hand, the accuracy challenge can be posed in terms of the tolerable clinical error associated with the procedure; on the other hand, accuracy is bound by the limitations of the system’s components, including modeling, patient registration, and surgical instrument tracking, all of which ultimately impact the overall targeting capabilities of the system. Methods While these processes are not unique to any interventional specialty, this paper discusses them in the context of two different cardiac image-guidance platforms: a model-enhanced ultrasound platform for intracardiac interventions and a prototype system for advanced visualization in image-guided cardiac ablation therapy. Results Pre-operative modeling techniques involving manual, semi-automatic and registration-based segmentation are discussed. The performance and limitations of clinically feasible approaches for patient registration evaluated both in the laboratory and operating room are presented. Our experience with two different magnetic tracking systems for instrument and ultrasound transducer localization is reported. Ultimately, the overall accuracy of the systems is discussed based on both in vitro and preliminary in vivo experience. Conclusion While clinical accuracy is specific to a particular patient and procedure and vastly dependent on the surgeon’s experience, the system’s engineering limitations are critical to determine whether the clinical requirements can be met. PMID:21671097
A change management approach to improving safety and preventing needle stick injuries.
Aziz, Ann-Marie
2017-09-01
Key drivers for preventing healthcare-associated infection (HCAI) include evidence-based practices and procedures that prevent infection. Among the current guidance for preventing HCAIs is evidence and mandatory requirements for reducing needle stick injuries (NSIs). This article highlights how John Kotter's model for change could help healthcare workers plan for successful and sustained deployment of needle safety devices (NSDs) and ultimately reduce the risk of a NSI.
Li, Zhiguang; Kwekel, Joshua C; Chen, Tao
2012-01-01
Functional comparison across microarray platforms is used to assess the comparability or similarity of the biological relevance associated with the gene expression data generated by multiple microarray platforms. Comparisons at the functional level are very important considering that the ultimate purpose of microarray technology is to determine the biological meaning behind the gene expression changes under a specific condition, not just to generate a list of genes. Herein, we present a method named percentage of overlapping functions (POF) and illustrate how it is used to perform the functional comparison of microarray data generated across multiple platforms. This method facilitates the determination of functional differences or similarities in microarray data generated from multiple array platforms across all the functions that are presented on these platforms. This method can also be used to compare the functional differences or similarities between experiments, projects, or laboratories.
NASA Technical Reports Server (NTRS)
Payne, Fred R.
1992-01-01
Lumley's 1967 Moscow paper provided, for the first time, a completely rational definition of the physically-useful term 'large eddy', popular for a half-century. The numerical procedures based upon his results are: (1) PODT (Proper Orthogonal Decomposition Theorem), which extracts the Large Eddy structure of stochastic processes from physical or computer simulation two-point covariances, and 2) LEIM (Large-Eddy Interaction Model), a predictive scheme for the dynamical large eddies based upon higher order turbulence modeling. Earlier Lumley's work (1964) forms the basis for the final member of the triad of numerical procedures: this predicts the global neutral modes of turbulence which have surprising agreement with both structural eigenmodes and those obtained from the dynamical equations. The ultimate goal of improved engineering design tools for turbulence may be near at hand, partly due to the power and storage of 'supermicrocomputer' workstations finally becoming adequate for the demanding numerics of these procedures.
Ganier, Franck; Hoareau, Charlotte; Tisseau, Jacques
2014-01-01
Virtual reality opens new opportunities for operator training in complex tasks. It lowers costs and has fewer constraints than traditional training. The ultimate goal of virtual training is to transfer knowledge gained in a virtual environment to an actual real-world setting. This study tested whether a maintenance procedure could be learnt equally well by virtual-environment and conventional training. Forty-two adults were divided into three equally sized groups: virtual training (GVT® [generic virtual training]), conventional training (using a real tank suspension and preparation station) and control (no training). Participants then performed the procedure individually in the real environment. Both training types (conventional and virtual) produced similar levels of performance when the procedure was carried out in real conditions. Performance level for the two trained groups was better in terms of success and time taken to complete the task, time spent consulting job instructions and number of times the instructor provided guidance.
Goff, B A; Muntz, H G; Cain, J M
1997-03-01
On January 1, 1992, Congress implemented a Medicare payment system based on relative value units (RVU). The RVU multiplied by a dollar conversion factor sets the reimbursement for all procedures covered by Medicare and many other private insurers. This study was undertaken to evaluate discrepancies in federal reimbursement for gender-specific procedures. Using the December 1995 Federal Register and the regional Medicare conversion factor ($40.08/RVU), we compared the work RVU and total reimbursement of 24 groups of gender-specific surgical procedures. The groups were matched as carefully as possible so that the amount of work and level of difficulty would be similar, if not identical. Some examples of comparisons are as follows: biopsy of male vs female genitals, hysterectomy vs prostatectomy, staging for ovarian vs testicular cancer, and exenteration for cervical vs prostate cancer. In the 24 matched procedures, the male-specific procedures were reimbursed at a higher amount in 19 (79%) cases. The female-specific procedures were reimbursed at a higher amount in 3 (12%) cases (P = 0.004). There was no difference in reimbursement for two of the comparisons. Overall, we found that male-specific procedures are reimbursed at an amount which is 44% higher than female-specific procedures. Comparison of work RVU revealed that male-specific procedures were assigned higher values in 19 cases and, overall, male gender-related surgeries had work RVU that were 50% higher than female gender-related surgeries. There is significant gender bias against the Medicare reimbursement of female-specific services. This results in a lower net reimbursement for gynecologic procedures. In addition, since many private sector insurance carriers now use the resource-based relative value scale system, this gender bias is further potentiated.
Algorithmic commonalities in the parallel environment
NASA Technical Reports Server (NTRS)
Mcanulty, Michael A.; Wainer, Michael S.
1987-01-01
The ultimate aim of this project was to analyze procedures from substantially different application areas to discover what is either common or peculiar in the process of conversion to the Massively Parallel Processor (MPP). Three areas were identified: molecular dynamic simulation, production systems (rule systems), and various graphics and vision algorithms. To date, only selected graphics procedures have been investigated. They are the most readily available, and produce the most visible results. These include simple polygon patch rendering, raycasting against a constructive solid geometric model, and stochastic or fractal based textured surface algorithms. Only the simplest of conversion strategies, mapping a major loop to the array, has been investigated so far. It is not entirely satisfactory.
Cole, Michael S; Carter, Min Z; Zhang, Zhen
2013-11-01
We examine the effect of (in)congruence between leaders' and teams' power distance values on team effectiveness. We hypothesize that the (in)congruence between these values would differentially predict team effectiveness, with procedural justice climate serving as a mediator. Using multisource data and polynomial regression, we found that similarities (and differences) between leaders' and their teams' power distance values can have consequential effects on teams' justice climate and, ultimately, their effectiveness (viz., team performance and team organizational citizenship behavior). We conclude that to fully understand the implications of power distance, one should consider the multiple perspectives of both leaders and team members. (c) 2013 APA, all rights reserved.
Roux-en-Y gastric bypass: effects on feeding behavior and underlying mechanisms
Manning, Sean; Pucci, Andrea; Batterham, Rachel L.
2015-01-01
Bariatric surgery is the most effective treatment for severe obesity, producing marked sustained weight loss with associated reduced morbidity and mortality. Roux-en-Y gastric bypass surgery (RYGBP), the most commonly performed procedure, was initially viewed as a hybrid restrictive-malabsorptive procedure. However, over the last decade, it has become apparent that alternative physiologic mechanisms underlie its beneficial effects. RYGBP-induced altered feeding behavior, including reduced appetite and changes in taste/food preferences, is now recognized as a key driver of the sustained postoperative weight loss. The brain ultimately determines feeding behavior, and here we review the mechanisms by which RYGBP may affect central appetite-regulating pathways. PMID:25729850
NASA Technical Reports Server (NTRS)
Edelstein, F.
1974-01-01
Heat pipe manufacturing methods are examined with the goal of establishing cost effective procedures that will ultimately result in cheaper more reliable heat pipes. Those methods which are commonly used by all heat pipe manufacturers have been considered, including: (1) envelope and wick cleaning, (2) end closure and welding, (3) mechanical verification, (4) evacuation and charging, (5) working fluid purity, and (6) charge tube pinch off. The study is limited to moderate temperature aluminum and stainless steel heat pipes with ammonia, Freon-21 and methanol working fluids. Review and evaluation of available manufacturers techniques and procedures together with the results of specific manufacturing oriented tests have yielded a set of recommended cost-effective specifications which can be used by all manufacturers.
The evolution of the midface lift in aesthetic plastic surgery.
Paul, Malcolm D; Calvert, Jay W; Evans, Gregory R D
2006-05-01
The midface lift has recently gained significant popularity with many surgeons. It allows the surgeon an opportunity to achieve greater facial harmony with facial rejuvenation procedures by correcting midfacial atrophy, addressing the tear trough deformity, and correcting the perceived malposition of the malar fat pad. This article examines the history of midfacial procedures. Surgical attempts at improving the aging face have evolved from minimal excisions and skin closure to aggressive dissections at multiple planes. The midface target area is peripheral to classic approaches, and its correction has required further anterior dissection from a distance or direct access centrally. Ultimately, conquering the stigmata of midface aging is entirely related to vectors and volume.
Parker, Dawn C.; Entwisle, Barbara; Rindfuss, Ronald R.; Vanwey, Leah K.; Manson, Steven M.; Moran, Emilio; An, Li; Deadman, Peter; Evans, Tom P.; Linderman, Marc; Rizi, S. Mohammad Mussavi; Malanson, George
2009-01-01
Cross-site comparisons of case studies have been identified as an important priority by the land-use science community. From an empirical perspective, such comparisons potentially allow generalizations that may contribute to production of global-scale land-use and land-cover change projections. From a theoretical perspective, such comparisons can inform development of a theory of land-use science by identifying potential hypotheses and supporting or refuting evidence. This paper undertakes a structured comparison of four case studies of land-use change in frontier regions that follow an agent-based modeling approach. Our hypothesis is that each case study represents a particular manifestation of a common process. Given differences in initial conditions among sites and the time at which the process is observed, actual mechanisms and outcomes are anticipated to differ substantially between sites. Our goal is to reveal both commonalities and differences among research sites, model implementations, and ultimately, conclusions derived from the modeling process. PMID:19960107
Parker, Dawn C; Entwisle, Barbara; Rindfuss, Ronald R; Vanwey, Leah K; Manson, Steven M; Moran, Emilio; An, Li; Deadman, Peter; Evans, Tom P; Linderman, Marc; Rizi, S Mohammad Mussavi; Malanson, George
2008-01-01
Cross-site comparisons of case studies have been identified as an important priority by the land-use science community. From an empirical perspective, such comparisons potentially allow generalizations that may contribute to production of global-scale land-use and land-cover change projections. From a theoretical perspective, such comparisons can inform development of a theory of land-use science by identifying potential hypotheses and supporting or refuting evidence. This paper undertakes a structured comparison of four case studies of land-use change in frontier regions that follow an agent-based modeling approach. Our hypothesis is that each case study represents a particular manifestation of a common process. Given differences in initial conditions among sites and the time at which the process is observed, actual mechanisms and outcomes are anticipated to differ substantially between sites. Our goal is to reveal both commonalities and differences among research sites, model implementations, and ultimately, conclusions derived from the modeling process.
Improving L2 Reading Comprehension through Emotionalized Dynamic Assessment Procedures.
Abdolrezapour, Parisa
2017-06-01
The paper reports a study on an emotionally-loaded dynamic assessment procedure used with Iranian EFL learners. It focuses on the effect of using emotional intelligence characteristics (based on Goleman's framework) as a tool for motivating learners while performing reading tasks. The study with 50 intermediate learners aged 12-15 used three modalities: a control group, which was taught under institute's normal procedures; a comparison group, which received dynamic assessment (DA); and an experimental group, which received emotionalized dynamic assessment (EDA) procedures, in the form of an intervention focusing on characteristics of Goleman's emotional intelligence framework with the express purpose of inducing them to work with their emotions. Results showed that applying EDA procedures to reading assessment tasks made a difference in learners' level of performance in comparison to those who went through pure DA procedures who in turn performed significantly better than those who did not received DA in any form.
ERIC Educational Resources Information Center
Dymond, Simon; Whelan, Robert
2010-01-01
Previous research suggests that the Relational Completion Procedure may be an effective alternative procedure for studying derived relational responding. However, the parameters that make it effective, relative to traditional match-to-sample, remain to be determined. The present experiment compared the Relational Completion Procedure and…
Acoustic emission analysis of fiber-reinforced composite in flexural testing.
Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2004-05-01
The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.
Representing and comparing protein structures as paths in three-dimensional space
Zhi, Degui; Krishna, S Sri; Cao, Haibo; Pevzner, Pavel; Godzik, Adam
2006-01-01
Background Most existing formulations of protein structure comparison are based on detailed atomic level descriptions of protein structures and bypass potential insights that arise from a higher-level abstraction. Results We propose a structure comparison approach based on a simplified representation of proteins that describes its three-dimensional path by local curvature along the generalized backbone of the polypeptide. We have implemented a dynamic programming procedure that aligns curvatures of proteins by optimizing a defined sum turning angle deviation measure. Conclusion Although our procedure does not directly optimize global structural similarity as measured by RMSD, our benchmarking results indicate that it can surprisingly well recover the structural similarity defined by structure classification databases and traditional structure alignment programs. In addition, our program can recognize similarities between structures with extensive conformation changes that are beyond the ability of traditional structure alignment programs. We demonstrate the applications of procedure to several contexts of structure comparison. An implementation of our procedure, CURVE, is available as a public webserver. PMID:17052359
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovanski, Yuri; Carsley, John; Carlson, Blair
2014-01-15
A comparison of welding techniques was performed to determine the most effective method for producing aluminum tailor-welded blanks for high volume automotive applications. Aluminum sheet was joined with an emphasis on post weld formability, surface quality and weld speed. Comparative results from several laser based welding techniques along with friction stir welding are presented. The results of this study demonstrate a quantitative comparison of weld methodologies in preparing tailor-welded aluminum stampings for high volume production in the automotive industry. Evaluation of nearly a dozen welding variations ultimately led to down selecting a single process based on post-weld quality and performance.
Jeffrey E. Schneiderman; Hong S. He; Frank R. Thompson; William D. Dijak; Jacob S. Fraser
2015-01-01
Tree species distribution and abundance are affected by forces operating across a hierarchy of ecological scales. Process and species distribution models have been developed emphasizing forces at different scales. Understanding model agreement across hierarchical scales provides perspective on prediction uncertainty and ultimately enables policy makers and managers to...
The Guardian. Volume 9, Number 3, Winter 2007
2007-01-01
message correctly. Muslims will ultimately determine whether the ideology of al Qaeda, its affiliates, franchisees , and fellow travelers represents...opined that the effort would not work or would not pass the cost– benefit comparison. Others wanted to develop comprehensive NATO doctrine to guide...full BAT capability, the access-control benefits of BAT/HIIDE are a significant improvement to overall ISAF force protection, even in stand-alone mode
ERIC Educational Resources Information Center
Capella-McDonnall, Michele
2007-01-01
The Ticket to Work (TTW) program is a federally funded program meant to assist persons who receive disability benefits from the Social Security Administration (SSA) in obtaining employment, with the ultimate goal of terminating SSA benefits and thereby providing a cost savings for the government. With its focus on employment, the TTW program would…
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
Thieme, Detlef; Sachs, Ulf; Sachs, Hans; Moore, Christine
2015-07-01
Formation of picolinic acid esters of hydroxylated drugs or their biotransformation products is a promising tool to improve their mass spectrometric ionization efficiency, alter their fragmentation behaviour and enhance sensitivity and specificity of their detection. The procedure was optimized and tested for the detection of cannabinoids, which proved to be most challenging when dealing with alternative specimens, for example hair and oral fluid. In particular, the detection of the THC metabolites hydroxyl-THC and carboxy-THC requires ultimate sensitivity because of their poor incorporation into hair or saliva. Both biotransformation products are widely accepted as incorporation markers to distinguish drug consumption from passive contamination. The derivatization procedure was carried out by adding a mixture of picolinic acid, 4-(dimethylamino)pyridine and 2-methyl-6-nitrobenzoic anhydride in tetrahydrofuran/triethylamine to the dry extraction residues. Resulting derivatives were found to be very stable and could be reconstituted in aqueous or organic buffers and subsequently analyzed by liquid chromatography-mass spectrometry (LC-MS). Owing to the complex consecutive fragmentation patterns, the application of multistage MS3 proved to be extremely useful for a sensitive identification of doubly picolinated hydroxy-THC in complex matrices. The detection limits - estimated by comparison of corresponding signal-to-noise ratios - increased by a factor of 100 following picolination. All other species examined, like cannabinol, THC, cannabidiol, and carboxy-THC, could also be derivatized exhibiting only moderate sensitivity improvements. The assay was systematically tested using hair samples and exemplarily applied to oral fluid. Concentrations of OH-THC identified in THC-positive hair samples ranged from 0.02 to 0.29pg/mg. Copyright © 2014 John Wiley & Sons, Ltd.
Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F
2016-07-26
The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient. Copyright © 2015 Elsevier Ltd. All rights reserved.
(T2L2) Time Transfer by Laser Link
NASA Technical Reports Server (NTRS)
Veillet, Christian; Fridelance, Patricia
1995-01-01
T2L2 (Time Transfer by Laser Link) is a new generation time transfer experiment based on the principles of LASSO (Laser Synchronization from Synchronous Orbit) and used with an operational procedure developed at OCA (Observatoire de la Cote d'Azur) during the active intercontinental phase of LASSO. The hardware improvements could lead to a precision better than 10 ps for time transfer (flying clock monitoring or ground based clock comparison). Such a package could fly on any spacecraft with a stable clock. It has been developed in France in the frame of the PHARAO project (cooled atom clock in orbit) involving CNES and different laboratories. But T2L2 could fly on any spacecraft carrying a stable oscillator. A GPS satellite would be a good candidate, as T2L2 could allow to link the flying clock directly to ground clocks using light, aiming to important accuracy checks, both for time and for geodesy. Radioastron (a flying VLBI antenna with a H-maser) is also envisioned, waiting for a PHARAO flight. The ultimate goal of T2L2 is to be part of more ambitious missions, as SORT (Solar Orbit Relativity Test), aiming to examine aspects of the gravitation in the vicinity of the Sun.
Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q
2013-08-01
The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p < 0.05), energy absorbed to yield (p < 0.05), and ultimate load (p < 0.05). For repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.
Hamze, Faeze; Ganjalikhan Nasab, Seyed Abdolreza; Eskandarizadeh, Ali; Shahravan, Arash; Akhavan Fard, Fatemeh; Sinaee, Neda
2018-01-01
Due to thermal hazard during composite restorations, this study was designed to scan the pulp temperature by thermocouple and infrared camera during photo polymerizing different composites. A mesio-occlso-distal (MOD) cavity was prepared in an extracted tooth and the K-type thermocouple was fixed in its pulp chamber. Subsequently, 1 mm increment of each composites were inserted (four composite types were incorporated) and photo polymerized employing either LED or QTH systems for 60 sec while the temperature was recorded with 10 sec intervals. Ultimately, the same tooth was hemisected bucco-lingually and the amalgam was removed. The same composite curing procedure was repeated while the thermogram was recorded using an infrared camera. Thereafter, the data was analyzed by repeated measured ANOVA followed by Tukey's HSD Post Hoc test for multiple comparisons ( α =0.05). The pulp temperature was significantly increased (repeated measures) during photo polymerization ( P =0.000) while there was no significant difference among the results recorded by thermocouple comparing to infrared camera ( P >0.05). Moreover, different composite materials and LCUs lead to similar outcomes ( P >0.05). Although various composites have significant different chemical compositions, they lead to similar pulp thermal changes. Moreover, both the infrared camera and the thermocouple would record parallel results of dental pulp temperature.
The Effects of Torsional Preloading on the Torsional Resistance of Nickel-titanium Instruments.
Oh, Seung-Hei; Ha, Jung-Hong; Kwak, Sang Won; Ahn, Shin Wook; Lee, WooCheol; Kim, Hyeon-Cheol
2017-01-01
This study evaluated the effect of torsional preloading on the torsional resistance of nickel-titanium (NiTi) endodontic instruments. WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper Universal F2 (Dentsply Maillefer) files were used. The ultimate torsional strength until fracture was determined for each instrument. In the phase 1 experiment, the ProTaper and WaveOne files were loaded to have a maximum load from 2.0 up to 2.7 or 2.8 Ncm, respectively. In the phase 2 experiment, the number of repetitions of preloading for each file was increased from 50 to 200, whereas the preloading torque was fixed at 2.4 Ncm. Using torsionally preloaded specimens from phase 1 and 2, the torsional resistances were calculated to determine the ultimate strength, distortion angle, and toughness. The results were analyzed using 1-way analysis of variance and Duncan post hoc comparison. The fracture surfaces and longitudinal aspect of 5 specimens per group were examined under a scanning electron microscope. All preloaded groups showed significantly higher ultimate strength than the unpreloaded groups (P < .05). There was no significant difference among all groups for distortion angle and toughness. Although WaveOne had no significant difference between the repetition groups for ultimate strength, fracture angle, and toughness, ProTaper had a higher distortion angle and toughness in the 50-repetition group compared with the other repetition groups (P < .05). Scanning electron microscopic examinations of the fractured surface showed typical features of torsional fracture. Torsional preloading within the ultimate values could enhance the torsional strength of NiTi instruments. The total energy until fracture was maintained constantly, regardless of the alloy type. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Tekçe, Neslihan; Tuncer, Safa; Demirci, Mustafa; Serim, Merve Efe; Baydemir, Canan
2015-11-01
The aim of this study was to evaluate the effect of three different drinks on the color parameters of four different restorative materials. Three different composites (Filtek Ultimate Universal Restorative, Filtek Ultimate Flowable, and Filtek Silorane, 3M ESPE) and a polyacid-modified composite resin material (Dyract XP, Dentsply DeTrey GmbH) were evaluated. Eighty-four disc-shaped specimens of 8 mm in diameter and 2 mm in thickness were prepared (n = 21 each). Color coordinates (L*a*b*, ΔL*, Δa*, Δb*, and ΔE*) were measured using a VİTA Easyshade Compact (VİTA Zahnfabrik) after 24 hr of storage (baseline) and after 30 day of storage in three different beverages of black tea, Coca cola, or water (control) (n = 7). In each beverage, the specimens were stored three times a day, one hr each, for 30 day. The color changes (ΔE) were calculated and were analyzed by Kruskal-Wallis and Dunn multiple comparison test. The color difference (ΔE*) of the resin materials ranged between 1.31 and 15.28 after 30 day of immersion in the staining solutions. Dyract XP in Coca cola (15.28 ± 2.61) and black tea (12.22 ± 2.73) showed the highest mean ΔE* value after 30 day, followed by Filtek Ultimate Universal Restorative (5.99 ± 1.25) and Filtek Ultimate Flowable (4.71 ± 1.40) in black tea (p < 0.05). The compomers displayed unacceptable color changes at the end of 30 day in all beverages. Among resin composites, the silorane based composite exhibited relatively good color stability than the others. Filtek Ultimate Universal Restorative and Filtek Flowable showed similar color changes in all beverages.
Thermal-Acoustic Analysis of a Metallic Integrated Thermal Protection System Structure
NASA Technical Reports Server (NTRS)
Behnke, Marlana N.; Sharma, Anurag; Przekop, Adam; Rizzi, Stephen A.
2010-01-01
A study is undertaken to investigate the response of a representative integrated thermal protection system structure under combined thermal, aerodynamic pressure, and acoustic loadings. A two-step procedure is offered and consists of a heat transfer analysis followed by a nonlinear dynamic analysis under a combined loading environment. Both analyses are carried out in physical degrees-of-freedom using implicit and explicit solution techniques available in the Abaqus commercial finite-element code. The initial study is conducted on a reduced-size structure to keep the computational effort contained while validating the procedure and exploring the effects of individual loadings. An analysis of a full size integrated thermal protection system structure, which is of ultimate interest, is subsequently presented. The procedure is demonstrated to be a viable approach for analysis of spacecraft and hypersonic vehicle structures under a typical mission cycle with combined loadings characterized by largely different time-scales.
Schroeder, Susan A.; Fulton, David C.
2017-01-01
Although researchers agree that public participation in natural resource decision making is critical to institutional acceptance by stakeholders and the general public, the processes to gain public perceptions of fairness, agency trust, and acceptance of management decisions are not clear. Using results from a mail survey of Minnesota resident anglers, we used structural equation modeling to examine how instrumental versus symbolic motives related to anglers’ perceptions of agency fairness, trustworthiness, and ultimately acceptance of fisheries management decisions. We applied laboratory research on relationships among procedural fairness, trust, and management acceptance, and then tested models incorporating anglers’ perceptions of voice for anglers and nonanglers in management decisions. Results suggested that trust fully mediated the relationship between procedural fairness and management acceptance. Angler perceptions of angler and nonangler voice both related to views of procedural fairness, but angler voice was more strongly related and was also significantly related to acceptance of management decisions.
Kold, S; Soballe, K; Mouzin, O; Chen, Xiangmei; Toft, M; Bechtold, J
2002-01-01
We used an experimental model producing a tissue response with a sclerotic endosteal neo-cortical rim associated with implant loosening in humans: a 6 mm PMMA cylinder pistoned 500 m concentrically in a 7.5 mm hole, with polyethylene particles. At a second operation at eight weeks, the standard revision procedure removed the fibrous membrane in one knee, and the crack revision procedure was used to crack the sclerotic endosteal rim in the contralateral knee. Once stability was achieved following the revision procedures, loaded Ti plasma sprayed implants were inserted into the revision cavities of 8 dogs for an additional 4 weeks. Revision implant fixation (ultimate shear strength and energy absorption) was significantly enhanced by cracking the sclerotic endosteal rim. In conclusion, we demonstrated a simple technique of cracking the sclerotic endosteal rim as an additional method for improving revision fixation. (Hip International 2002; 2: 77-9).
Brylinski, Michal; Konieczny, Leszek; Kononowicz, Andrzej; Roterman, Irena
2008-03-21
The well-known procedure implemented in ClustalW oriented on the sequence comparison was applied to structure comparison. The consensus sequence as well as consensus structure has been defined for proteins belonging to serpine family. The structure of early stage intermediate was the object for similarity search. The high values of W(sequence) appeared to be accordant with high values of W(structure) making possible structure comparison using common criteria for sequence and structure comparison. Since the early stage structural form has been created according to limited conformational sub-space which does not include the beta-structure (this structure is mediated by C7eq structural form), is particularly important to see, that the C7eq structural form may be treated as the seed for beta-structure present in the final native structure of protein. The applicability of ClustalW procedure to structure comparison makes these two comparisons unified.
Sexual Harassment and Grievance Procedures Training Package
1992-06-03
who feel excluded or undervalued. Seemingly small cosmetic insensitivities can have a significant impact on unit morale, cohesion and ultimately...ABUSE, AND ARE NOW THE LEADERS OF OUR SOCIETY IN PROVIDING DRUG FREE LIVING AND WORKING ENVIRONMENTS. TODAY, WE MUST CONFRONT ANOTHER ISSUE AFFECTING OUR...AND SEXUAL OFFENSES WOULD NOT BE TOLERATED. IN REF B9 I MADE IT ^LEAR THAT I JOT ONLY SUPPORTED SECNAVVS STRONG COMMITMENT TO A NAVY FREE OF SEXUAL
Application of Toxicity Identification and Evaluation Procedures for Dredged Material Management
2017-02-01
that may pose a risk to human health and the environment. The potential for risk ultimately depends on the final disposition of the dredged material... human health and ecological receptors. This information is also useful when evaluating dredged material for open water disposal since it could eliminate...and potential for exposure to humans or ecological receptors. The Inland Testing and Ocean Disposal Manuals establish a multi-step testing protocol
Virtual reality for mine safety training.
Filigenzi, M T; Orr, T J; Ruff, T M
2000-06-01
Mining has long remained one of America's most hazardous occupations. Researchers believe that by developing realistic, affordable VR training software, miners will be able to receive accurate training in hazard recognition and avoidance. In addition, the VR software will allow miners to follow mine evacuation routes and safe procedures without exposing themselves to danger. This VR software may ultimately be tailored to provide training in other industries, such as the construction, agricultural, and petroleum industries.
1991-07-31
harvesting and road building in two national forests. The case study sites were the Siuslaw National Forest near Corvallis, Oregon, and the Porcupine ...million would accrue to recreational and commercial anglers from the clearcutting alternative. For the Porcupine - Hyalite Wilderness Study Area in Montana...impact environmental factors (e.g., available habitat, hunting area, or size of elk herds ), and ultimately those quality factors of the recreation
Acquisition of delayed matching in the pigeon.
Berryman, R; Cumming, W W; Nevin, J A
1963-01-01
Pigeons were exposed to three successive matching-to-sample procedures. On a given trial, the sample (red, green or blue light) appeared on a center key; observing responses to this key produced the comparison stimuli on two side keys. Seven different experimental conditions could govern the temporal relations between the sample and comparison stimuli. In the "simultaneous" condition, the center key response was followed immediately by illumination of the side key comparison stimuli, with the center key remaining on. In "zero delay" the center key response simultaneously turned the side keys on and the center key off, while in the "variable delay" conditions, intervals of 1, 2, 4, 10, and 24 sec were interposed between the offset of the sample and the appearance of the comparison stimuli on the side keys. In all conditions, a response to the side key of matching hue produced reinforcement, while a response to the non-matching side key was followed by a blackout. In procedure I all seven experimental conditions were presented in randomly permutated order. After nine sessions of exposure (at 191 trials per session, for a total of 1719 trials) the birds gave no evidence of acquisition in any of the conditions. They were therefore transferred to Procedure II, which required them to match only in the "simultaneous" condition, with both the sample and comparison stimuli present at the same time. With the exception of one bird, all subjects acquired this performance to near 100% levels. Next, in Procedure III, they were once more exposed to presentation of all seven experimental conditions in random order. In contrast to Procedure I, they now acquired the delay performance, and were able to match effectively at delays of about 4 sec.
De Carolis, S; Botta, A; Del Sordo, Gelsomina; Guerrisi, R; Salvi, S; De Carolis, M P; Iaconelli, A; Giustacchini, P; Raffaelli, M; Lanzone, A
2018-06-16
Pregnancy after bariatric surgery (BS) has an increased risk for small-for-gestational-age infants (SGA), shorter length of gestation, and probably perinatal mortality. The aim of this study was to investigate if biliopancreatic diversion could impair pregnancy outcomes in comparison to other bariatric surgery procedures. We conducted a cohort retrospective single-center study in 65 women before and after BS. Thirty-one pregnancies occurred before BS, while 109 after BS, amongst which n = 51 after biliopancreatic diversion (BPD) and n = 58 after non-malabsorptive procedures. The pregnancy outcomes after BS in comparison with those before BS resulted less affected by diabetes, hypertensive disorders, macrosomia, and large-for-gestational-age (LGA), but more complicated by preterm births (14.5 versus 4.0%) and low birth weight (LBW) infants (28.9 versus 0%). Moreover, mean birth weight resulted lower after BS than before BS (p < 0.001). In pregnancies after BPD in comparison to those before BS, the LBW rate (42.5%) resulted a drastic increase (p < 0.001), and mean birth weight (p < 0.001) and mean birth weight centile (p < 0.001) were lower after BPD. When pregnancy outcomes after BPD were compared with those after non-malabsorptive procedures, the rate of congenital anomalies, preterm births, LBW, and SGA resulted an increase (p = 0.002, 0.008, 0.032, and < 0.001, respectively). BPD drastically reduced diabetes, hypertensive disorders, macrosomia, and LGA; however, it was associated with the poorest pregnancy outcomes in comparison to those observed after other BS procedures. On the basis of the present study, we recommend a cautious multidisciplinary selection of severely obese patients for BPD during the fertile age.
ERIC Educational Resources Information Center
Lee, Eunjung
2013-01-01
The purpose of this research was to compare the equating performance of various equating procedures for the multidimensional tests. To examine the various equating procedures, simulated data sets were used that were generated based on a multidimensional item response theory (MIRT) framework. Various equating procedures were examined, including…
A Comparison of Standard-Setting Procedures for an OSCE in Undergraduate Medical Education.
ERIC Educational Resources Information Center
Kaufman, David M.; Mann, Karen V.; Muijtjens, Arno M. M.; van der Vleuten, Cees P. M.
2000-01-01
Compared four standard-setting procedures for an objective structure clinical examination (OSCE) in medical education. Applied Angoff, borderline, relative, and holistic procedures to the data used to establish a cutoff score for a pass/fail decision. The Angoff and borderline procedures gave similar results; however, the relative and holistic…
The Measurement of Values: Effects of Different Assessment Procedures
ERIC Educational Resources Information Center
Feather, N. T.
1973-01-01
Rating and pair-comparison procedures for assessing the importance of terminal and instrumental values were compared with the standard ranking procedure developed by Rokeach. Effects of order of presentation of of the value sets were also investigated. Neither procedure nor order had replicable effect though some sex differences were apparent. (TO)
A Comparison of Exposure Control Procedures in CATs Using the 3PL Model
ERIC Educational Resources Information Center
Leroux, Audrey J.; Lopez, Myriam; Hembry, Ian; Dodd, Barbara G.
2013-01-01
This study compares the progressive-restricted standard error (PR-SE) exposure control procedure to three commonly used procedures in computerized adaptive testing, the randomesque, Sympson-Hetter (SH), and no exposure control methods. The performance of these four procedures is evaluated using the three-parameter logistic model under the…
NASA Technical Reports Server (NTRS)
Lovoy, C. V.
1978-01-01
Fillet size is discussed in terms of theoretical or design dimensions versus as-welded dimensions, drawing attention to the inherent conservatism in the design load sustaining capabilities of fillet welds. Emphasis is placed on components for the solid rocket motor, external tank, and other aerospace applications. Problems associated with inspection of fillet welds are addresses and a comparison is drawn between defect counts obtained by radiographic inspection and by visual examination of the fracture plane. Fillet weld quality is related linearly to ultimate shear strength. Correlation coefficients are obtained by simple straight line regression analysis between the variables of ultimate shear strength and accumulative discontinuity summation. Shear strength allowables are found to be equivalent to 57 percent of butt weld A allowables (F sub tu.)
L'Hommedieu, Coles E; Gera, James J; Rupp, Gerald; Salin, Jeffery W; Cox, John S; Duwelius, Paul J
2016-09-01
Controversy exists as to which surgical approach is best for total hip arthroplasty (THA). Previous studies suggested that the tissue-sparing anterior approach should result in a more rapid recovery requiring fewer postacute services, ultimately decreasing overall episodic cost. The purpose of this cross-sectional study was to determine if any significant differences exist between the anterior vs posterior approaches on postacute care service utilization, readmissions, or episodic cost. Claims data from 26,773 Medicare fee-for-service beneficiaries receiving elective THAs (Medical Severity-Diagnosis Related Groups (MS-DRGs) 469/470) were analyzed. Claims data were collected from the 2-year period, January 2013 through December 2014. The posterior surgical approach was performed on 23,653 patients while 3120 patients received the anterior approach. Data analysis showed negligible effect sizes in postacute care service utilization, readmission rate, and cost between the surgical approaches for elective THA (MS-DRG 469 and 470). Average THA total episode cost was negligibly higher for procedures using the anterior approach compared to the posterior approach ($22,517 and $22,068, respectively). Statistically significant differences were observed in inpatient rehab and home health cost and service utilization. However, the effect sizes of these comparisons are negligible when accounting for the large sample size. All other comparisons showed minimal and statistically insignificant variation. The results indicate that surgical approach alone is not the primary driver of postacute care service utilization, quality outcomes, or cost. Other factors such as physician-led patient-focused care pathways, care coordination, rapid rehabilitation protocols, perioperative pain management protocols, and patient education are integral for effective patient care. Copyright © 2016 Elsevier Inc. All rights reserved.
A comment on the PCAST report: Skip the "match"/"non-match" stage.
Morrison, Geoffrey Stewart; Kaye, David H; Balding, David J; Taylor, Duncan; Dawid, Philip; Aitken, Colin G G; Gittelson, Simone; Zadora, Grzegorz; Robertson, Bernard; Willis, Sheila; Pope, Susan; Neil, Martin; Martire, Kristy A; Hepler, Amanda; Gill, Richard D; Jamieson, Allan; de Zoete, Jacob; Ostrum, R Brent; Caliebe, Amke
2017-03-01
This letter comments on the report "Forensic science in criminal courts: Ensuring scientific validity of feature-comparison methods" recently released by the President's Council of Advisors on Science and Technology (PCAST). The report advocates a procedure for evaluation of forensic evidence that is a two-stage procedure in which the first stage is "match"/"non-match" and the second stage is empirical assessment of sensitivity (correct acceptance) and false alarm (false acceptance) rates. Almost always, quantitative data from feature-comparison methods are continuously-valued and have within-source variability. We explain why a two-stage procedure is not appropriate for this type of data, and recommend use of statistical procedures which are appropriate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
van der Linden, Wim J.; Eggen, Theo J. H. M.
A procedure for the sequential optimization of the calibration of an item bank is given. The procedure is based on an empirical Bayes approach to a reformulation of the Rasch model as a model for paired comparisons between the difficulties of test items in which ties are allowed to occur. First, it is indicated how a paired-comparisons design…
Krejci, Ivo; Daher, René
2017-04-01
The goal of this short communication is to present finite element analysis comparison of the stress distribution between CAD/CAM full crowns made of Lava Ultimate and of IPS e.max CAD, adhesively luted to natural teeth and to implant abutments with the shape of natural teeth. Six 3D models were prepared using a 3D content-creating software, based on a micro-CT scan of a human mandibular molar. The geometry of the full crown and of the abutment was the same for all models representing Lava Ultimate full crowns (L) and IPS e.max CAD full crowns (E) on three different abutments: prepared natural tooth (n), titanium abutment (t) and zirconia abutment (z). A static load of 400 N was applied on the vestibular and lingual cusps, and fixtures were applied to the base of the models. After running the static linear analysis, the post-processing data we analyzed. The stress values at the interface between the crown and the abutment of the Lt and Lz groups were significantly higher than the stress values at the same interface of all the other models. The high stress concentration in the adhesive at the interface between the crown and the abutment of the Lava Ultimate group on implants might be one of the factors contributing to the reported debondings of crowns.
Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.
Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M
2001-05-01
To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.
de Waha, Suzanne; Seeburger, Joerg; Ender, Joerg; Desch, Steffen; Eitel, Ingo; Reinhardt, Adrian; Pöss, Janine; Fuernau, Georg; Noack, Thilo; Merk, Denis Rouven; Schuler, Gerhard; Sievers, Hans-Hinrich; Mohr, Friedrich-Wilhelm; Thiele, Holger
2016-06-01
Percutaneous edge-to-edge mitral valve reconstruction (PMVR) has emerged as a treatment option in patients with severe mitral regurgitation not considered suitable candidates for surgery. The majority of PMVR procedures are performed under general anesthesia (GA), although deep sedation (DS) appears to be an attractive alternative. We thus sought to assess the impact on intensive care unit (ICU) length of stay, efficacy, and safety of DS in comparison to GA in patients undergoing PMVR using the MitraClip(®) system. Sixty consecutive patients underwent PMVR procedures at two centers. The first 30 patients were treated by GA followed by 30 patients undergoing DS under different settings. The primary clinical endpoint was ICU length of stay. The primary efficacy endpoint included procedural success and procedural duration. The safety endpoint was defined as a composite of death, stroke, cardiogenic shock, moderate and severe bleeding as well as pneumonia. The ICU length of stay was significantly shorter in the DS group in comparison to GA patients (p = 0.001). The hospital length of stay did not differ following DS in comparison to GA (p = 0.96). Procedural success was high in both groups (100 versus 96.7 %, p = 0.34) at similar procedural duration time (p = 0.60). No difference between GA and DS was observed with respect to the occurrence of the combined safety endpoint (p = 0.47). In comparison to GA, DS reduces the ICU length of stay in PMVR without negative effects on safety and efficacy. Prospective randomized trials are needed to confirm these findings.
Harmonization in laboratory medicine: Requests, samples, measurements and reports.
Plebani, Mario
2016-01-01
In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.
A comparison of calibration techniques for hot-wires operated in subsonic compressible slip flows
NASA Technical Reports Server (NTRS)
Jones, Gregory S.; Stainback, P. C.; Nagabushana, K. A.
1992-01-01
This paper focuses on the correlation of constant temperature anemometer voltages to velocity, density, and total temperature in the transonic slip flow regime. Three different calibration schemes were evaluated. The ultimate use of these hot-wire calibrations is to obtain fluctuations in the flow variables. Without the appropriate mean flow sensitivities of the heated wire, the measurements of these fluctuations cannot be accurately determined.
ERIC Educational Resources Information Center
Salih, Karimeldin M. A.; Alshehri, Mohamed Abdullah Al-Gosadi; Elfaki, Omer Abdelgadir
2016-01-01
Objectives: To investigate the relation between the students' scores in MCQs and MEQs of the summative assessment in pediatrics at the College of medicine KKU. Introduction: Student assessment is the most difficult task in medicine since it is ultimately related to human life and safety. Assessment can take different types of formats with…
Sustainable Land Use for Bioenergy in the 21st Century
2011-06-01
as pyrolysis and gasification are also applicable to burn biomass and produce electricity.61–63 Biomass can be used directly in existing co- fired...engineering specifications that may ultimately lead to high process efficiency. COMPARISON OF BIOMASS THERMAL CONVERSION PROCESSES Gasification ...thermal gasification of biomass and its application to electricity and fuel production. Biomass and Bioenergy 2008;32(7):573–581. 62. Caputo AC
Rating curve uncertainty: A comparison of estimation methods
Mason, Jr., Robert R.; Kiang, Julie E.; Cohn, Timothy A.; Constantinescu, George; Garcia, Marcelo H.; Hanes, Dan
2016-01-01
The USGS is engaged in both internal development and collaborative efforts to evaluate existing methods for characterizing the uncertainty of streamflow measurements (gaugings), stage-discharge relations (ratings), and, ultimately, the streamflow records derived from them. This paper provides a brief overview of two candidate methods that may be used to characterize the uncertainty of ratings, and illustrates the results of their application to the ratings of the two USGS streamgages.
NASA Astrophysics Data System (ADS)
Orth, C. D.
2001-03-01
This paper reviews our current understanding of the relative advantages of direct drive (DD) and indirect drive (ID) for a 1 GWe inertial fusion energy (IFE) power plant driven by a diode-pumped solid-state laser (DPSSL). This comparison is motivated by a recent study (1) that shows that the projected cost of electricity (COE) for DD is actually about the same as that for ID even though the target gain for DD can be much larger. We can therefore no longer assume that DD is the ultimate targeting scenario for IFE, and must begin a more rigorous comparison of these two drive options. The comparison begun here shows that ID may actually end up being preferred, but the uncertainties are still rather large.
Aanen, Duur K
2006-01-01
At present there is no consensus theory explaining the evolutionary stability of mutualistic interactions. However, the question is whether there are general ‘rules’, or whether each particular mutualism needs a unique explanation. Here, I address the ultimate evolutionary stability of the ‘agricultural’ mutualism between fungus-growing termites and Termitomyces fungi, and provide a proximate mechanism for how stability is achieved. The key to the proposed mechanism is the within-nest propagation mode of fungal symbionts by termites. The termites suppress horizontal fungal transmission by consuming modified unripe mushrooms (nodules) for food. However, these nodules provide asexual gut-resistant spores that form the inoculum of new substrate. This within-nest propagation has two important consequences: (i) the mutualistic fungi undergo severe, recurrent bottlenecks, so that the fungus is likely to be in monoculture and (ii) the termites ‘artificially’ select for high nodule production, because their fungal food source also provides the inoculum for the next harvest. I also provide a brief comparison of the termite–fungus mutualism with the analogous agricultural mutualism between attine ants and fungi. This comparison shows that—although common factors for the ultimate evolutionary stability of mutualisms can be identified—the proximate mechanisms can be fundamentally different between different mutualisms. PMID:17148364
Ethics guidelines for research with the recently dead.
Pentz, Rebecca D; Cohen, Cynthia B; Wicclair, Mark; DeVita, Michael A; Flamm, Anne Lederman; Youngner, Stuart J; Hamric, Ann B; McCabe, Mary S; Glover, Jacqueline J; Kittiko, Winona J; Kinlaw, Kathy; Keller, James; Asch, Adrienne; Kavanagh, John J; Arap, Wadih
2005-11-01
The objective of the multidisciplinary expert Consensus Panel on Research with the Recently Dead (CPRRD) was to craft ethics guidelines for research with the recently dead. The CPRRD recommends that research with the recently dead: (i) receive scientific and ethical review and oversight; (ii) involve the community of potential research subjects; (iii) be coordinated with organ procurement organizations; (iv) not conflict with organ donation or required autopsy; (v) use procedures respectful of the dead; (vi) be restricted to one procedure per day; (vii) preferably be authorized by first-person consent, though both general advance research directives and surrogate consent are acceptable; (viii) protect confidentiality; (ix) not impose costs on subjects' estates or next of kin and not involve payment; (x) clearly explain ultimate disposition of the body.
ERIC Educational Resources Information Center
Sanetti, Lisa M. Hagermoser; Collier-Meek, Melissa A.
2014-01-01
Although it is widely accepted that procedural fidelity data are important for making valid decisions about intervention effectiveness, there is little empirical guidance for researchers and practitioners regarding how to assess procedural fidelity. A first step in moving procedural fidelity assessment research forward is to develop a…
... blood will be taken before the procedure for comparison with the fetal blood samples. During the procedure ... Healthy Living," and the triple-shield Mayo Clinic logo are trademarks of Mayo Foundation for Medical Education ...
NASA Technical Reports Server (NTRS)
Bergan, Andrew; Bakuckas, John G., Jr.; Lovejoy, Andrew; Jegley, Dawn; Linton, Kim; Neal, Bert; Korkosz, Gregory; Awerbuch, Jonathan; Tan, Tein-Min
2012-01-01
Integrally stitched composite technology is an area that shows promise in enhancing the structural integrity of aircraft and aerospace structures. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. The goal of the PRSEUS concept relevant to this test is to provide damage containment capability for composite structures while reducing overall structural weight. The National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), and The Boeing Company have partnered in an effort to assess the damage containment features of a full-scale curved PRSEUS panel using the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. A single PRSEUS test panel was subjected to axial tension, internal pressure, and combined axial tension and internal pressure loads. The test results showed excellent performance of the PRSEUS concept. No growth of Barely Visible Impact Damage (BVID) was observed after ultimate loads were applied. With a two-bay notch severing the central stringer, damage was contained within the two-bay region well above the required limit load conditions. Catastrophic failure was well above the ultimate load level. Information describing the test panel and procedure has been previously presented, so this paper focuses on the experimental procedure, test results, nondestructive inspection results, and preliminary test and analysis correlation.
Achieving Consistent Doppler Measurements from SDO/HMI Vector Field Inversions
NASA Technical Reports Server (NTRS)
Schuck, Peter W.; Antiochos, S. K.; Leka, K. D.; Barnes, Graham
2016-01-01
NASA's Solar Dynamics Observatory is delivering vector magnetic field observations of the full solar disk with unprecedented temporal and spatial resolution; however, the satellite is in a highly inclined geosynchronous orbit. The relative spacecraft-Sun velocity varies by +/-3 kms-1 over a day, which introduces major orbital artifacts in the Helioseismic Magnetic Imager (HMI) data. We demonstrate that the orbital artifacts contaminate all spatial and temporal scales in the data. We describe a newly developed three-stage procedure for mitigating these artifacts in the Doppler data obtained from the Milne-Eddington inversions in the HMI pipeline. The procedure ultimately uses 32 velocity-dependent coefficients to adjust 10 million pixels-a remarkably sparse correction model given the complexity of the orbital artifacts. This procedure was applied to full-disk images of AR 11084 to produce consistent Dopplergrams. The data adjustments reduce the power in the orbital artifacts by 31 dB. Furthermore, we analyze in detail the corrected images and show that our procedure greatly improves the temporal and spectral properties of the data without adding any new artifacts. We conclude that this new procedure makes a dramatic improvement in the consistency of the HMI data and in its usefulness for precision scientific studies.
Watanabe, Hiroshi
2012-01-01
Procedures of statistical analysis are reviewed to provide an overview of applications of statistics for general use. Topics that are dealt with are inference on a population, comparison of two populations with respect to means and probabilities, and multiple comparisons. This study is the second part of series in which we survey medical statistics. Arguments related to statistical associations and regressions will be made in subsequent papers.
Probabilistic Modeling of Ceramic Matrix Composite Strength
NASA Technical Reports Server (NTRS)
Shan, Ashwin R.; Murthy, Pappu L. N.; Mital, Subodh K.; Bhatt, Ramakrishna T.
1998-01-01
Uncertainties associated with the primitive random variables such as manufacturing process (processing temperature, fiber volume ratio, void volume ratio), constituent properties (fiber, matrix and interface), and geometric parameters (ply thickness, interphase thickness) have been simulated to quantify the scatter in the first matrix cracking strength (FMCS) and the ultimate tensile strength of SCS-6/RBSN (SiC fiber (SCS-6) reinforced reaction-bonded silicon nitride composite) ceramic matrix composite laminate at room temperature. Cumulative probability distribution function for the FMCS and ultimate tensile strength at room temperature (RT) of (0)(sub 8), (0(sub 2)/90(sub 2), and (+/-45(sub 2))(sub S) laminates have been simulated and the sensitivity of primitive variables to the respective strengths have been quantified. Computationally predicted scatter of the strengths for a uniaxial laminate have been compared with those from limited experimental data. Also the experimental procedure used in the tests has been described briefly. Results show a very good agreement between the computational simulation and the experimental data. Dominating failure modes in (0)(sub 8), (0/90)(sub s) and (+/-45)(sub S) laminates have been identified. Results indicate that the first matrix cracking strength for the (0)(sub S), and (0/90)(sub S) laminates is sensitive to the thermal properties, modulus and strengths of both the fiber and matrix whereas the ultimate tensile strength is sensitive to the fiber strength and the fiber volume ratio. In the case of a (+/-45)(sub S), laminate, both the FMCS and the ultimate tensile strengths have a small scatter range and are sensitive to the fiber tensile strength as well as the fiber volume ratio.
Evaluation of the Elastic Properties of Thirteen Silicone Interocclusal Recording Materials
Zietek, Marek
2016-01-01
Background. Addition silicones are popular as dental impression materials and are used in bite registration procedures. Objective. This study aimed to compare the postsetting elasticities and other mechanical properties of thirteen addition silicone interocclusal recording materials. Materials and Methods. The following materials were investigated: Colorbite D, Futar D, Genie Bite, Jet Blue Bite fast, Memoreg 2, O-Bite, Occlufast Rock, Omni-Bite Plus, Regidur i, Registrado X-tra, Regofix transparent, StoneBite, and Variotime Bite. Thirty specimens of each material were tested. The elasticities and strengths of the materials were measured with a universal testing machine, and computer software was used to determine the E-moduli, ultimate tensile strengths, and ultimate elongations of the specimens. Results. The results were subjected to statistical analysis using the Kruskal-Wallis test (p ≤ 0.05). The statistics revealed that the mean E-modulus values varied significantly across the materials (p = 0.000) and were highest for the StoneBite and Registrado X-tra and lowest for the Regofix transparent. The ultimate tensile strengths were highest for the Regofix transparent and Registrado X-tra (p = 0.000) and lowest for the Jet Blue Bite fast and Memoreg 2 (p = 0.000). The elongation percentages at the point of breaking varied significantly across the materials (p = 0.000); the lowest value was observed for the StoneBite, whereas the Regofix transparent nearly doubled original length. Conclusions. The authors concluded that materials with the high E-moduli and great ultimate tensile strengths may be most useful clinically. Registrado X-tra and StoneBite best met these criteria. PMID:27747239
NASA Astrophysics Data System (ADS)
Su, Ray Kai Leung; Lee, Chien-Liang
2013-06-01
This study presents a seismic fragility analysis and ultimate spectral displacement assessment of regular low-rise masonry infilled (MI) reinforced concrete (RC) buildings using a coefficient-based method. The coefficient-based method does not require a complicated finite element analysis; instead, it is a simplified procedure for assessing the spectral acceleration and displacement of buildings subjected to earthquakes. A regression analysis was first performed to obtain the best-fitting equations for the inter-story drift ratio (IDR) and period shift factor of low-rise MI RC buildings in response to the peak ground acceleration of earthquakes using published results obtained from shaking table tests. Both spectral acceleration- and spectral displacement-based fragility curves under various damage states (in terms of IDR) were then constructed using the coefficient-based method. Finally, the spectral displacements of low-rise MI RC buildings at the ultimate (or nearcollapse) state obtained from this paper and the literature were compared. The simulation results indicate that the fragility curves obtained from this study and other previous work correspond well. Furthermore, most of the spectral displacements of low-rise MI RC buildings at the ultimate state from the literature fall within the bounded spectral displacements predicted by the coefficient-based method.
Post-Buckling and Ultimate Strength Analysis of Stiffened Composite Panel Base on Progressive Damage
NASA Astrophysics Data System (ADS)
Zhang, Guofan; Sun, Xiasheng; Sun, Zhonglei
Stiffened composite panel is the typical thin wall structure applied in aerospace industry, and its main failure mode is buckling subjected to compressive loading. In this paper, the development of an analysis approach using Finite Element Method on post-buckling behavior of stiffened composite structures under compression was presented. Then, the numerical results of stiffened panel are obtained by FE simulations. A thorough comparison were accomplished by comparing the load carrying capacity and key position strains of the specimen with test. The comparison indicates that the FEM results which adopted developed methodology could meet the demand of engineering application in predicting the post-buckling behavior of intact stiffened structures in aircraft design stage.
Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.
2011-01-01
OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842
Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J
2011-08-01
To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.
Bakircioglu, Dilek; Kurtulus, Yasemin Bakircioglu; Yurtsever, Selcuk
2013-06-01
The content of elements (Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) in edible oils (sunflower, hazelnut, canola, corn and olive oils) from Turkey was determined using inductively coupled plasma optical emission spectrometry (ICP-OES) after ultrasonic extraction, wet digestion, and extraction induced by emulsion breaking procedures (EIEB). In order to evaluate the best sample preparation procedure, EIEB procedure was compared by ultrasonic extraction and wet digestion procedures. The results in the samples (minimum-maximum in mgkg(-1)) were : 0.022-0.058, Cr 0.126-7.106, Cu 0.570-4.504, Fe 8.004-12.588, Mn 0.035-0.054, Ni 0.908-2.182, Pb 0.099-0.134 and Zn 2.206-8.982. The EIEB procedure was found to be fast, reliable, simple, and excellent in comparison with the other studied procedures. The recovery test was performed by spiking the samples with known amounts of the metals in the form of organometallic standards and applying the EIEB procedure. The recoveries were in the range of 96-109%. Copyright © 2012 Elsevier Ltd. All rights reserved.
Failure mode analysis in adrenal vein sampling: a single-center experience.
Trerotola, Scott O; Asmar, Melissa; Yan, Yan; Fraker, Douglas L; Cohen, Debbie L
2014-10-01
To analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling. A retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique. AVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism. A substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some "failed" AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Wingfield, C; Amis, A A; Stead, A C; Law, H T
2000-07-01
An in vitro study of rottweiler and racing greyhound cranial cruciate ligaments revealed that the rottweiler ligaments had a significantly greater cross-sectional area at their distal attachments. Mechanical testing showed that the ultimate load related to body mass was significantly higher in the extended racing greyhound stifle during cranial tibial loading to failure, as were linear stiffness, tensile strength and tangent modulus. During ligament axis loading to failure, the only significant difference in structural and mechanical properties recorded between the two breeds was a greater ultimate strain for the greyhound ligament with the stifle joint flexed. Energy absorbed by the ligament complex at failure during cranial tibial loading was twice that for ligament axis loading for both breeds. The clinical significance is that the rottweiler cranial cruciate ligament is more vulnerable to damage as it requires half the load per unit body mass that the greyhound requires to cause a rupture.
Xu, Bin; Yang, Chenguang; Pan, Yongping
2015-10-01
This paper studies both indirect and direct global neural control of strict-feedback systems in the presence of unknown dynamics, using the dynamic surface control (DSC) technique in a novel manner. A new switching mechanism is designed to combine an adaptive neural controller in the neural approximation domain, together with the robust controller that pulls the transient states back into the neural approximation domain from the outside. In comparison with the conventional control techniques, which could only achieve semiglobally uniformly ultimately bounded stability, the proposed control scheme guarantees all the signals in the closed-loop system are globally uniformly ultimately bounded, such that the conventional constraints on initial conditions of the neural control system can be relaxed. The simulation studies of hypersonic flight vehicle (HFV) are performed to demonstrate the effectiveness of the proposed global neural DSC design.
Butt, Amna; Ayaz Khan, Mohammad; Khan, Ijaz; Saqib, Imad-ud-din; Hussain, Tariq; Akhter, Saeed
2017-01-01
Introduction With the increased use of extracorporeal shock wave lithotripsy (ESWL), the management of urolithiasis has become much convenient for the patients and the health care professionals alike. However, associated with the procedure is the common complaint of pain. No agreed upon pain management strategy has yet been developed for the procedure. We compared the effect of different analgesia drug regiments for pain control. Methodology A randomised controlled trial was carried out in Shifa International Hospital from between July 2015 to January 2016. A total of 135 patients were divided into three groups; group A received 30 g lidocaine 2% gel applied locally on corresponding lumber area 30 minutes before the procedure, group B received oral naproxen sodium 550 mg 45 minutes before the procedure, and group C received both oral naproxen and lidocaine gel. Patients were supplemented with intravenous nalbuphine during the procedure. The pain was assessed with 0-10 visual analogue scale. Both pre-procedure and post-procedure pain score was measured. Results Among 135 patients, 105 (77.8%) were male and 29 (21.5%) were female with mean age of 38.7 ± 1.31 years. There was no difference of mean pain score or need for supplemental intravenous nalbuphine between groups B and C but there was significantly decreased mean pain score and need for supplemental intravenous nalbuphine in groups B and C in comparison with group A. Conclusion The use of oral naproxen sodium with or without the addition of lidocaine gel during ESWL is a promising option for pain management during the procedure with significant improvement in comparison with lidocaine gel alone. PMID:28560121
Mitchell, Jean M; Carey, Kathleen
2016-02-01
Ambulatory surgery centers (ASCs) are freestanding facilities that specialize in surgical and diagnostic procedures that do not require an overnight stay. While it is generally assumed that ASCs are less costly than hospital outpatient surgery departments, there is sparse empirical evidence regarding their relative production costs. To estimate ASC production costs using financial and claims records for procedures performed by surgery centers that specialize in gastroenterology procedures (colonoscopy and endoscopy). We estimate production costs in ASCs that specialize in gastroenterology procedures using financial cost and patient discharge data from Pennsylvania for the time period 2004-2013. We focus on the 2 primary procedures (colonoscopies and endoscopies) performed at each ASC. We use our estimates to predict average costs for each procedure and then compare predicted costs to Medicare ACS payments for these procedures. Comparisons of the costs of each procedure with 2013 national Medicare ASC payment rates suggest that Medicare payments exceed production costs for both colonoscopy and endoscopy. This study demonstrated that it is feasible to estimate production costs for procedures performed in freestanding surgery centers. The procedure-specific cost estimates can then be compared with ASC payment rates to ascertain if payments are aligned with costs. This approach can serve as an evaluation template for CMS and private insurers who are concerned that ASC facility payments for specific procedures may be excessive.
Deforestation, Rondonia, Brazil
NASA Technical Reports Server (NTRS)
1992-01-01
This view of deforestation in Rondonia, far western Brazil, (10.0S, 63.0W) is part of an agricultural resettlement project which ultimately covers an area about 80% the size of France. The patterns of deforestation in this part of the Amazon River Basin are usually aligned adjacent to highways, secondary roads, and streams for ease of access and transportation. Compare this view with the earlier 51G-37-062 for a comparison of deforestation in the region.
Deforestation, Rondonia, Brazil
1992-08-08
This view of deforestation in Rondonia, far western Brazil, (10.0S, 63.0W) is part of an agricultural resettlement project which ultimately covers an area about 80% the size of France. The patterns of deforestation in this part of the Amazon River Basin are usually aligned adjacent to highways, secondary roads, and streams for ease of access and transportation. Compare this view with the earlier 51G-37-062 for a comparison of deforestation in the region.
Thomas L Eberhardt; Hui Pan
2013-01-01
Gasification of biomass ultimately generates at least one solid byproduct in which the inorganic constituents of the biomass are concentrated. Given the potential for utilization, or issues with disposal, facile methods are needed for determining the compositions of the fly ashes from recently-available gasifier-based bioenergy systems. Proton induced x-ray emission...
ERIC Educational Resources Information Center
Mumuni, Samad Dimbie
2010-01-01
This study compared the six principles of IDEIA of the United States and the Persons with Disability Act of Ghana with the view to determining their similarities and differences. Recommendations were made with the ultimate aim of exploring the need for change in the special education delivery systems in the United States and Ghana. The comparative…
DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Lim, Hae W; Plummer, Lisa; Baker, James; Kowalski, Marcin; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter
2014-06-01
Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon with regard to hospital resource allocation. There was no statistical difference between cryoballoon and RF catheters for acute PVI success during the ablation procedure.
Procedural and Logic Programming: A Comparison.
ERIC Educational Resources Information Center
Watkins, Will; And Others
1988-01-01
Examines the similarities and fundamental differences between procedural programing and logic programing by comparing LogoWriter and PROLOG. Suggests that PROLOG may be a good first programing language for students to learn. (MVL)
Energy data report: prices and margins of No. 2 distillate fuel oil. Monthly report, January 1982
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whatley, A.
1982-03-22
Data are presented on the average prices and gross margins for the refining, reselling, and retailing sectors of the No. 2 distillate fuel oil market. Data are tabulated on prices and sales volumes of No. 2 fuel oil and No. 2 diesel fuel for residential, industrial/commercial, institutional/utility, other ultimate consumer sales, and nonultimate consumer sales. A brief discussion of the sampling and estimation procedures used in this report appears in the appendix.
Energy data report: prices and margins of No. 2 distillate fuel oil. Monthly report, October 1982
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whatley, A.
1982-12-20
Data are presented on the average prices and gross margins for the refining, reselling, and retailing sectors of the No. 2 distillate fuel oil market. Data are tabulated on prices and sales volumes of No. 2 fuel oil and No. 2 diesel fuel for residential, industrial/commercial, institutional/utility, other ultimate consumer sales, and nonultimate consumer sales. A brief discussion of the sampling and estimation procedures used in this report appears in the appendix.
Energy data report: prices and margins of No. 2 distillate fuel oil. Monthly report, November 1982
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whatley, A.
1983-01-18
Data are presented on the average prices and gross margins for the refining, reselling, and retailing sectors of the No. 2 distillate fuel oil market. Data are tabulated on prices and sales volumes of No. 2 fuel oil and No. 2 diesel fuel for residential, industrial/commercial, institutional/utility, other ultimate consumer sales, and nonultimate consumer sales. A brief discussion of the sampling and estimation procedures used in this report appears in the appendix.
Energy data report: prices and margins of No. 2 distillate fuel oil. Monthly report, December 1981
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whatley, A.
1982-02-22
Data are presented on the average prices and gross margins for the refining, reselling, and retailing sectors of the No. 2 distillate fuel oil market. Data are tabulated on prices and sales volumes of No. 2 fuel oil and No. 2 diesel fuel for residential, industrial/commercial, institutional/utility, other ultimate consumer sales, and nonultimate consumer sales. A brief discussion of the sampling and estimation procedures used in this report appears in the appendix.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noguchi, R.A.
1994-06-01
Composite materials are affected by environments differently than conventional airframe structural materials are. This study identifies the environmental conditions which the composite-airframe ARM UAV may encounter, and discusses the potential degradation processes composite materials may undergo when subjected to those environments. This information is intended to be useful in a follow-on program to develop equipment and procedures to prevent, detect, or otherwise mitigate significant degradation with the ultimate goal of preventing catastrophic aircraft failure.
The Mechanics of Long Bone Fractures.
1981-01-31
r = .99) between wet density and ultimate bending strength for 37 specimens of human femoral bone. Evans (1973) studied embalmed human tibial...Work 2 2.2 Methods 6 2.2.1 Torsional Loading 6 2.2.2 The Effects of Combined Loading 10 2.2.3 Cancellous Bone Effects 11 2.3 Results 11 2.3.1...PROPERTIES 21 3.1 Previous Work 22 3.2 Methods 26 3.2.1 Cross Sectional Property Software 26 3.2.2 CT Scanning Procedure 28 3.2.3 Linear Dependency of
40 CFR 258.53 - Ground-water sampling and analysis requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... include consistent sampling and analysis procedures that are designed to ensure monitoring results that... testing period. If a multiple comparisons procedure is used, the Type I experiment wise error rate for...
Comparison of methods for hydrocarbon analysis of marine biota
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gritz, R.L.; Shaw, D.G.
1977-04-01
A comparison was made of several procedures for the isolation of hydrocarbons from other matter and for the fractionation of hydrocarbons according to chemical type. The efficiency of Soxhlet extraction followed by saponification with extraction by alkaline digestion (direct saponification) was compared using two hour and 24 hour reaction times. All procedures were performed on approximately 60 g of soft parts of Saxidomus gigantea (butter clam). The 24 hour saponification and column chromatography on partially deactivated columns constituted the best procedure tested. Soxhlet extraction followed by two hour saponification did not completely remove methyl esters and was the most laboriousmore » technique. Direct two hour saponification was also questionable in the removal of esters and led to severe emulsion problems. The recoveries of hydrocarbons by the three procedures was substantially the same.« less
Selecting Evaluation Comparison Groups: A Cluster Analytic Approach.
ERIC Educational Resources Information Center
Davis, Todd Mclin; McLean, James E.
A persistent problem in the evaluation of field-based projects is the lack of no-treatment comparison groups. Frequently, potential comparison groups are confounded by socioeconomic, racial, or other factors. Among the possible methods for dealing with this problem are various matching procedures, but they are cumbersome to use with multiple…
Inverse boundary-layer theory and comparison with experiment
NASA Technical Reports Server (NTRS)
Carter, J. E.
1978-01-01
Inverse boundary layer computational procedures, which permit nonsingular solutions at separation and reattachment, are presented. In the first technique, which is for incompressible flow, the displacement thickness is prescribed; in the second technique, for compressible flow, a perturbation mass flow is the prescribed condition. The pressure is deduced implicitly along with the solution in each of these techniques. Laminar and turbulent computations, which are typical of separated flow, are presented and comparisons are made with experimental data. In both inverse procedures, finite difference techniques are used along with Newton iteration. The resulting procedure is no more complicated than conventional boundary layer computations. These separated boundary layer techniques appear to be well suited for complete viscous-inviscid interaction computations.
Therapeutic cloning: from consequences to contradiction.
Coors, Marilyn
2002-06-01
The British Parliament legalized therapeutic cloning in December 2000 despite opposition from the European Union. The watershed event in Parliament's move was the active and unprecedented government support for the generation and destruction of human embryonic life merely as a means of medical advancement. This article contends that the utilitarian analysis of this procedure is necessary to identify the real world risks of therapeutic cloning but insufficient to identify the breach of defensible ethical limits that this procedure represents. A value-oriented approach to Kantian ethics demonstrates that the utilitarian endorsement of therapeutic cloning entails a contradiction of the necessity of human vulnerability and a faulty valuation of the human embryo. The concern is that a narrow utilitarian focus ultimately commodifies human embryonic life and preferences outcomes as the sole determinant of moral value.
Vulnerability assessments as a political creation: tsunami management in Portugal.
Pronk, Maartje; Maat, Harro; Crane, Todd A
2017-10-01
Vulnerability assessments are a cornerstone of contemporary disaster research. This paper shows how research procedures and the presentation of results of vulnerability assessments are politically filtered. Using data from a study of tsunami risk assessment in Portugal, the paper demonstrates that approaches, measurement instruments, and research procedures for evaluating vulnerability are influenced by institutional preferences, lines of communication, or lack thereof, between stakeholder groups, and available technical expertise. The institutional setting and the pattern of stakeholder interactions form a filter, resulting in a particular conceptualisation of vulnerability, affecting its operationalisation via existing methods and technologies and its institutional embedding. The Portuguese case reveals a conceptualisation that is aligned with perceptions prevalent in national government bureaucracies and the exclusion of local stakeholders owing to selected methodologies and assessment procedures. The decisions taken by actors involved in these areas affect how vulnerability is assessed, and ultimately which vulnerability reduction policies will be recommended in the appraisal. © 2017 The Author(s). Disasters © Overseas Development Institute, 2017.
A Comparison of Match-to-Sample and Respondent-Type Training of Equivalence Classes
ERIC Educational Resources Information Center
Clayton, Michael C.; Hayes, Linda J.
2004-01-01
Throughout the 25-year history of research on stimulus equivalence, one feature of the training procedure has remained constant, namely, the requirement of operant responding during the training procedures. The present investigation compared the traditional match-to-sample (MTS) training with a more recent respondent-type (ReT) procedure. Another…
A Comparison of Error-Correction Procedures on Skill Acquisition during Discrete-Trial Instruction
ERIC Educational Resources Information Center
Carroll, Regina A.; Joachim, Brad T.; St. Peter, Claire C.; Robinson, Nicole
2015-01-01
Previous research supports the use of a variety of error-correction procedures to facilitate skill acquisition during discrete-trial instruction. We used an adapted alternating treatments design to compare the effects of 4 commonly used error-correction procedures on skill acquisition for 2 children with attention deficit hyperactivity disorder…
A Comparison of Heuristic Procedures for Minimum within-Cluster Sums of Squares Partitioning
ERIC Educational Resources Information Center
Brusco, Michael J.; Steinley, Douglas
2007-01-01
Perhaps the most common criterion for partitioning a data set is the minimization of the within-cluster sums of squared deviation from cluster centroids. Although optimal solution procedures for within-cluster sums of squares (WCSS) partitioning are computationally feasible for small data sets, heuristic procedures are required for most practical…
A Comparison of a Bayesian and a Maximum Likelihood Tailored Testing Procedure.
ERIC Educational Resources Information Center
McKinley, Robert L.; Reckase, Mark D.
A study was conducted to compare tailored testing procedures based on a Bayesian ability estimation technique and on a maximum likelihood ability estimation technique. The Bayesian tailored testing procedure selected items so as to minimize the posterior variance of the ability estimate distribution, while the maximum likelihood tailored testing…
A Comparison of Intraverbal Training Procedures for Children with Autism
ERIC Educational Resources Information Center
Kodak, Tiffany; Fuchtman, Rashea; Paden, Amber
2012-01-01
We compared the effectiveness of three training procedures, echoic and tact prompting plus error correction and a cues-pause-point (CPP) procedure, for increasing intraverbals in 2 children with autism. We also measured echoic behavior that may have interfered with appropriate question answering. Results indicated that echoic prompting with error…
NASA Technical Reports Server (NTRS)
Williams, B. F.
1976-01-01
Manufacturing techniques are evaluated using expenses based on experience and studying basic cost factors for each step to evaluate expenses from a first-principles point of view. A formal cost accounting procedure is developed which is used throughout the study for cost comparisons. The first test of this procedure is a comparison of its predicted costs for array module manufacturing with costs from a study which is based on experience factors. A manufacturing cost estimate for array modules of $10/W is based on present-day manufacturing techniques, expenses, and materials costs.
Burkhart, Stephen S; Adams, Christopher R; Burkhart, Sarah S; Schoolfield, John D
2009-03-01
The purpose of this study was to compare the biomechanical fixation parameters of a standard double-row rotator cuff repair with those of a knotless footprint reconstruction using the double-row SwiveLock-FiberChain technique (Arthrex, Naples, FL). Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 48 +/- 10.3 years). A shoulder from each matched pair was randomly selected to receive a standard 4-anchor double-row repair of the supraspinatus tendon, and the contralateral shoulder received a 4-anchor double-row SwiveLock-FiberChain repair. The tendon was cycled from 10 N to 100 N at 1 Hz for 500 cycles, followed by a single-cycle pull to failure at 33 mm/s. Yield load, ultimate load, cyclic displacement, and mode of failure were recorded. Yield load and ultimate load were higher for the SwiveLock-FiberChain repair compared with the standard double-row repair for 6 of the 7 treatment pairs; however, 1 cadaver had a contrary outcome, so the overall mean differences in yield load and ultimate load were not significantly different from 0 by Student t test (P > .15). Furthermore, smaller differences between yield load and ultimate load for the SwiveLock-FiberChain repair in 5 of the 7 treatment pairs showed a self-reinforcing mechanism. Double-row footprint reconstruction with the knotless SwiveLock-FiberChain system in this study had yield loads, ultimate loads, and cyclic displacements that were statistically equivalent to those of standard double-row rotation cuff reconstructions. The SwiveLock-FiberChain system's combination of strength, self-reinforcement, and decreased operating time may offer advantages to the surgeon, particularly when dealing with older patients in whom poor tissue quality and total operative time are important considerations.
Applying probabilistic well-performance parameters to assessments of shale-gas resources
Charpentier, Ronald R.; Cook, Troy
2010-01-01
In assessing continuous oil and gas resources, such as shale gas, it is important to describe not only the ultimately producible volumes, but also the expected well performance. This description is critical to any cost analysis or production scheduling. A probabilistic approach facilitates (1) the inclusion of variability in well performance within a continuous accumulation, and (2) the use of data from developed accumulations as analogs for the assessment of undeveloped accumulations. In assessing continuous oil and gas resources of the United States, the U.S. Geological Survey analyzed production data from many shale-gas accumulations. Analyses of four of these accumulations (the Barnett, Woodford, Fayetteville, and Haynesville shales) are presented here as examples of the variability of well performance. For example, the distribution of initial monthly production rates for Barnett vertical wells shows a noticeable change with time, first increasing because of improved completion practices, then decreasing from a combination of decreased reservoir pressure (in infill wells) and drilling in less productive areas. Within a partially developed accumulation, historical production data from that accumulation can be used to estimate production characteristics of undrilled areas. An understanding of the probabilistic relations between variables, such as between initial production and decline rates, can improve estimates of ultimate production. Time trends or spatial trends in production data can be clarified by plots and maps. The data can also be divided into subsets depending on well-drilling or well-completion techniques, such as vertical in relation to horizontal wells. For hypothetical or lightly developed accumulations, one can either make comparisons to a specific well-developed accumulation or to the entire range of available developed accumulations. Comparison of the distributions of initial monthly production rates of the four shale-gas accumulations that were studied shows substantial overlap. However, because of differences in decline rates among them, the resulting estimated ultimate recovery (EUR) distributions are considerably different.
Menzies, Jennifer Z; McDonough, Kathleen; McAvoy, Drew; Federle, Thomas W
2017-02-01
The ultimate disposition of chemicals discarded down the drain can be substantially impacted by their fate in the sewer, but to date limited data have been published on the biodegradability of chemicals in sewer systems. The recently established OECD 314 guideline (Simulation tests to assess the biodegradability of chemicals discharged in wastewater, 2008) contains a simulation method (314A) for evaluating the biodegradation of chemicals in sewage under simulated sewer conditions. This research used the OECD 314A method to evaluate the rates and pathways of primary and ultimate biodegradation of a suite of 14 C-labeled homologues representing four classes of high volume surfactants including nonionic alkyl ethoxylates (AE), and anionic alkyl ethoxysulfates (AES), alkyl sulfate (AS) and linear alkyl benzene sulfonate (LAS). All the tested homologues exhibited >97 % loss of parent, formation of metabolites, and some level (16-94 %) of CO 2 production after being incubated 96-100 h in raw domestic wastewater. Comparison of C 12 E 3 , C 14 E 3 , and C 16 E 3 showed that the first order biodegradation rate was affected by alkyl chain length with rates ranging from 6.8 h -1 for C 12 E 3 to 0.49 h -1 for C 16 E 3 . Conversely, comparison of C 14 E 1 , C 14 E 3 , and C 14 E 9 showed that the number of ethoxy units did not impact the biodegradation rate. AES and AS degraded quickly with first order kinetic rates of 1.9-3.7 and 41 h -1 respectively. LAS did not exhibit first order decay kinetics and primary degradation was slow. Biodegradation pathways were also determined. This work shows that biodegradation in the sewer has a substantial impact on levels of surfactants and surfactant metabolites that ultimately reach wastewater treatment plants.
Performance assessment of solid state actuators through a common procedure and comparison criteria
NASA Astrophysics Data System (ADS)
Reithler, Livier; Guedra-Degeorges, Didier
1998-07-01
The design of systems based on smart structure technologies for active shape and vibration control and high precision positioning requires a good knowledge of the behavior of the active materials (electrostrictive and piezoelectric ceramics and polymers, magnetostrictive and shape memory alloys...) and of commercially available actuators. Extensive theoretical studies have been made on the behavior of active materials during the past decades but there are only a few developments on experimental comparisons between different kinds of commercially available actuators. The purpose of this study is to find out the pertinent parameters for the design of such systems, to set up a common static test procedure for all types of actuators and to define comparison criteria in terms of output force and displacement, mechanical and electrical energy, mass and dimensions. After having define the pertinent parameters of the characterization and having described the resulting testing procedure, test results are presented for different types of actuators based on piezoceramics and magnetostrictive alloys. The performances of each actuator are compared through both the test results and the announced characteristics: to perform this comparison absolute and relative criteria are chosen considering aeronautical and space applications.
Hamze, Faeze; Ganjalikhan Nasab, Seyed Abdolreza; Eskandarizadeh, Ali; Shahravan, Arash; Akhavan Fard, Fatemeh; Sinaee, Neda
2018-01-01
Introduction: Due to thermal hazard during composite restorations, this study was designed to scan the pulp temperature by thermocouple and infrared camera during photo polymerizing different composites. Methods and Materials: A mesio-occlso-distal (MOD) cavity was prepared in an extracted tooth and the K-type thermocouple was fixed in its pulp chamber. Subsequently, 1 mm increment of each composites were inserted (four composite types were incorporated) and photo polymerized employing either LED or QTH systems for 60 sec while the temperature was recorded with 10 sec intervals. Ultimately, the same tooth was hemisected bucco-lingually and the amalgam was removed. The same composite curing procedure was repeated while the thermogram was recorded using an infrared camera. Thereafter, the data was analyzed by repeated measured ANOVA followed by Tukey’s HSD Post Hoc test for multiple comparisons (α=0.05). Results: The pulp temperature was significantly increased (repeated measures) during photo polymerization (P=0.000) while there was no significant difference among the results recorded by thermocouple comparing to infrared camera (P>0.05). Moreover, different composite materials and LCUs lead to similar outcomes (P>0.05). Conclusion: Although various composites have significant different chemical compositions, they lead to similar pulp thermal changes. Moreover, both the infrared camera and the thermocouple would record parallel results of dental pulp temperature. PMID:29707014
Open-source image registration for MRI-TRUS fusion-guided prostate interventions.
Fedorov, Andriy; Khallaghi, Siavash; Sánchez, C Antonio; Lasso, Andras; Fels, Sidney; Tuncali, Kemal; Sugar, Emily Neubauer; Kapur, Tina; Zhang, Chenxi; Wells, William; Nguyen, Paul L; Abolmaesumi, Purang; Tempany, Clare
2015-06-01
We propose two software tools for non-rigid registration of MRI and transrectal ultrasound (TRUS) images of the prostate. Our ultimate goal is to develop an open-source solution to support MRI-TRUS fusion image guidance of prostate interventions, such as targeted biopsy for prostate cancer detection and focal therapy. It is widely hypothesized that image registration is an essential component in such systems. The two non-rigid registration methods are: (1) a deformable registration of the prostate segmentation distance maps with B-spline regularization and (2) a finite element-based deformable registration of the segmentation surfaces in the presence of partial data. We evaluate the methods retrospectively using clinical patient image data collected during standard clinical procedures. Computation time and Target Registration Error (TRE) calculated at the expert-identified anatomical landmarks were used as quantitative measures for the evaluation. The presented image registration tools were capable of completing deformable registration computation within 5 min. Average TRE was approximately 3 mm for both methods, which is comparable with the slice thickness in our MRI data. Both tools are available under nonrestrictive open-source license. We release open-source tools that may be used for registration during MRI-TRUS-guided prostate interventions. Our tools implement novel registration approaches and produce acceptable registration results. We believe these tools will lower the barriers in development and deployment of interventional research solutions and facilitate comparison with similar tools.
NASA Astrophysics Data System (ADS)
Zhu, Qiao; Huang, Xiao-Feng; Cao, Li-Ming; Wei, Lin-Tong; Zhang, Bin; He, Ling-Yan; Elser, Miriam; Canonaco, Francesco; Slowik, Jay G.; Bozzetti, Carlo; El-Haddad, Imad; Prévôt, André S. H.
2018-02-01
Organic aerosols (OAs), which consist of thousands of complex compounds emitted from various sources, constitute one of the major components of fine particulate matter. The traditional positive matrix factorization (PMF) method often apportions aerosol mass spectrometer (AMS) organic datasets into less meaningful or mixed factors, especially in complex urban cases. In this study, an improved source apportionment method using a bilinear model of the multilinear engine (ME-2) was applied to OAs collected during the heavily polluted season from two Chinese megacities located in the north and south with an Aerodyne high-resolution aerosol mass spectrometer (HR-ToF-AMS). We applied a rather novel procedure for utilization of prior information and selecting optimal solutions, which does not necessarily depend on other studies. Ultimately, six reasonable factors were clearly resolved and quantified for both sites by constraining one or more factors: hydrocarbon-like OA (HOA), cooking-related OA (COA), biomass burning OA (BBOA), coal combustion (CCOA), less-oxidized oxygenated OA (LO-OOA) and more-oxidized oxygenated OA (MO-OOA). In comparison, the traditional PMF method could not effectively resolve the appropriate factors, e.g., BBOA and CCOA, in the solutions. Moreover, coal combustion and traffic emissions were determined to be primarily responsible for the concentrations of PAHs and BC, respectively, through the regression analyses of the ME-2 results.
NASA Astrophysics Data System (ADS)
Silvestro, Paolo Cosmo; Yang, Hao; Jin, X. L.; Yang, Guijun; Casa, Raffaele; Pignatti, Stefano
2016-08-01
The ultimate aim of this work is to develop methods for the assimilation of the biophysical variables estimated by remote sensing in a suitable crop growth model. Two strategies were followed, one based on the use of Leaf Area Index (LAI) estimated by optical data, and the other based on the use of biomass estimated by SAR. The first one estimates LAI from the reflectance measured by the optical sensors on board of HJ1A, HJ1B and Landsat, using a method based on the training of artificial neural networks (ANN) with PROSAIL model simulations. The retrieved LAI is used to improve wheat yield estimation, using assimilation methods based on the Ensemble Kalman Filter, which assimilate the biophysical variables into growth crop model. The second strategy estimates biomass from SAR imagery. Polarimetric decomposition methods were used based on multi-temporal fully polarimetric Radarsat-2 data during the entire growing season. The estimated biomass was assimilating to FAO Aqua crop model for improving the winter wheat yield estimation, with the Particle Swarm Optimization (PSO) method. These procedures were used in a spatial application with data collected in the rural area of Yangling (Shaanxi Province) in 2014 and were validated for a number of wheat fields for which ground yield data had been recorded and according to statistical yield data for the area.
Technology and surgery. Dilemma of the gimmick, true advances, and cost effectiveness.
Traverso, L W
1996-02-01
The key to evaluating a procedure in regard to a true advance versus a gimmick is to determine its value. This can be done only by physicians cognizant of a disease process. The value is determined by assessing a procedure's utilization, outcomes, and costs. Utilization allows early treatment and avoids neglected disease. Therefore, the appropriateness of the utilization can be determined only by an outcome study. An outcome study is another term for quality assessment. Outcomes deal with morbidity, mortality, and also the long- and short-term effects of the procedure on the disease. Overall, an increase of quality in a global perspective decreases the costs of the procedure to the health care community. Costs must remain secondary to outcomes. An attempt to decrease costs directly is a maneuver that, when applied by nonmedical individuals, will most likely decrease quality. When the quality can be maintained (as assessed only by a practitioner), then a decrease in global costs will increase value. The concept of increasing value by increasing quality without an attempt to decrease costs is a very important principle that the health care system must learn in our ever-challenging medical environment. Is a new procedure a gimmick or a true advance? The decision is made jointly by the stakeholders in our health care system--the patient, provider, payer, employer, and industry. If the procedure does not receive negative votes, then its adoption is almost assured. Comparing two procedures through these perspectives ultimately allows us to determine the potential for new procedures. A procedure not adopted through this method could be called a gimmick.
A comparison of intraverbal training procedures for children with autism.
Kodak, Tiffany; Fuchtman, Rashea; Paden, Amber
2012-01-01
We compared the effectiveness of three training procedures, echoic and tact prompting plus error correction and a cues-pause-point (CPP) procedure, for increasing intraverbals in 2 children with autism. We also measured echoic behavior that may have interfered with appropriate question answering. Results indicated that echoic prompting with error correction was most effective and the CPP procedure was least effective for increasing intraverbals and decreasing echoic behavior.
Tautomerism in chemical information management systems
NASA Astrophysics Data System (ADS)
Warr, Wendy A.
2010-06-01
Tautomerism has an impact on many of the processes in chemical information management systems including novelty checking during registration into chemical structure databases; storage of structures; exact and substructure searching in chemical structure databases; and depiction of structures retrieved by a search. The approaches taken by 27 different software vendors and database producers are compared. It is hoped that this comparison will act as a discussion document that could ultimately improve databases and software for researchers in the future.
NASA Astrophysics Data System (ADS)
Fernandes, A. M.; Smith, V.
2017-12-01
A downstream reduction in bed material flux is associated with the backwater zone, where rivers in their terminal reaches deepen to respond to the sea-level in the receiving basin. This downstream change in sediment transport is reflected in: a) lateral channel mobility, and b) sedimentology and stratigraphic architecture of composite depositional bodies that are left behind. Here we draw comparisons between the Mississippi River and the Trinity River (TX), in terms of bar morphologies and composition, and lateral mobility of these rivers. Across the backwater transition, both rivers display a slight increase in lateral migration rates, followed by substantial decrease lateral migration in the terminal reaches. Both rivers also display predominantly symmetrical channel cross-sections, coincident with very small migration rates in the terminal reaches. We will discuss how the divergence in sediment transport flux across the backwater zone relates to the volume and shape of bank-attached bars, which in turn relates to the cross-sectional shapes of the channels as well as their lateral migrations rates, and ultimately defines the internal architecture of the composite channel deposits that result. Furthermore, we draw comparisons between the morphologies of bank-attached bars and channels in rivers and submarine channels to present insights into how the dominant mode of sediment transport in these different environments ultimately controls the morphologies and kinematics of these channels.
Kumar, Naina; Singh, Namit Kant; Rudra, Samar; Pathak, Swanand
2017-01-01
Direct Observation of Procedural Skills (DOPS) is a way of evaluating procedural skills through observation in the workplace. The purpose of this study was to assess the role of DOPS in teaching and assessment of postgraduate students and to know the effect of repeated DOPS on improvement of the skills and confidence of the students. In both phases, significant difference was observed between the two groups on first DOPS comparison (1st phase: p=0.000; 2nd phase: p=0.002), with simulation group performing better. Comparison of sixth DOPS in the two groups revealed no difference in both phases, but significant difference on first and sixth DOPS comparison in each group (p=0.000). Repeated DOPS results in improved skills and confidence of students in managing real life obstetric emergencies irrespective of the teaching modality. Repeated DOPS results in improved skills and confidence of students in managing real life obstetric emergencies irrespective of the teaching modality.
COMPARISON OF SCREENING APPROACHES
Neurobehavioral techniques have been used extensively n an ma toxicology studies because, in many Gases, such procedures are designed to evaluate neurobiological functions thought to be affected in chemical-exposed humans, e.g., changes in sensorimotor function. procedures used t...
The Role of Injectables in Aesthetic Surgery: Financial Implications.
Richards, Bryson G; Schleicher, William F; D'Souza, Gehaan F; Isakov, Raymond; Zins, James E
2017-10-01
The plastic surgeon competes with both core and noncore physicians and surgeons for traditional cosmetic procedures. In 2007, the American Society for Aesthetic Plastic Surgery (ASAPS) and the American Society of Plastic Surgeons (ASPS) joined efforts to form a Cosmetic Medicine Task Force to further analyze this trend. Our objective is to document and quantify the patient capture and total collections generated in a single surgeon's practice exclusive from Botulinum Toxin A and filler injections over a 10-year period. We subsequently identified the effect and importance that fillers and Botulinum Toxin A have on an active cosmetic practice. A retrospective chart review of all male and female patients who received Botulinum Toxin A or soft tissue filler injections (noninvasive aesthetic treatment) in a single surgeons practice from January 2004 to December 2013 was undertaken. Only those patients new to the practice and who were exclusively seeking out Botulinum Toxin A or fillers were included in the study. Chart review then identified which of these selected patients ultimately underwent invasive aesthetic surgery during this 10-year period. Noninvasive and invasive aesthetic surgery total collections were calculated using billing records. From January 2004 to December 2013, 375 patients entered the senior surgeon's practice specifically requesting and receiving noninvasive aesthetic treatments. Of these 375 patients, 59 patients (15.7%) subsequently underwent an aesthetic surgery procedure at an average of 19 months following initial noninvasive aesthetic treatment. Of these 375 patients, 369 were female and 6 were male. The most common initial invasive aesthetic procedure performed after injectable treatment included 22 facelifts (18.5%), 21 upper eyelid blepharoplasties (17.6%), and 15 endoscopic brow lifts (12.6%). Total collections from noninvasive aesthetic sessions and invasive surgery combined represented US$762,470 over this 10-year span. This represented US$524,771 and US$396,166 in total collections for injectables and surgery respectively. Noninvasive aesthetic surgery is a critical part of a plastic surgery practice. A measurable and significant number of patients who sought out a single plastic surgeon exclusively for noninvasive treatment ultimately underwent traditional invasive cosmetic surgical procedures. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Zhang, Niu; Chawla, Sudeep
2012-01-01
This study examined the effect of implementing instructional video in ophthalmic physical examination teaching on chiropractic students' laboratory physical examination skills and written test results. Instructional video clips of ophthalmic physical examination, consisting of both standard procedures and common mistakes, were created and used for laboratory teaching. The video clips were also available for student review after class. Students' laboratory skills and written test results were analyzed and compared using one-way analysis of variance (ANOVA) and post hoc multiple comparison tests among three study cohorts: the comparison cohort who did not utilize the instructional videos as a tool, the standard video cohort who viewed only the standard procedure of video clips, and the mistake-referenced video cohort who viewed video clips containing both standard procedure and common mistakes. One-way ANOVA suggested a significant difference of lab results among the three cohorts. Post hoc multiple comparisons further revealed that the mean scores of both video cohorts were significantly higher than that of the comparison cohort (p < .001). There was, however, no significant difference of the mean scores between the two video cohorts (p > .05). However, the percentage of students having a perfect score was the highest in the mistake-referenced video cohort. There was no significant difference of written test scores among all three cohorts (p > .05). The instructional video of the standard procedure improves chiropractic students' ophthalmic physical examination skills, which may be further enhanced by implementing a mistake-referenced instructional video.
Code Blue on Orbit: Treating Cardiac Arrest on the ISS
NASA Technical Reports Server (NTRS)
Bacal, Kira; Redmond, Melissa
2004-01-01
As a result of the Columbia tragedy on February 1,2003, the International Space Station (ISS) crew size has been temporarily reduced from three to two. This change forces adaptations in many operational procedures used by the crew, including medical protocols which were designed for scenarios involving one casualty and two caregivers. The Office of Space Medicine directed that the procedure for the resuscitation of a crewmember in cardiac arrest be rewritten for use by a single care provider. Methods: Adaptation of this procedure made use of current American Heart Association Advanced Cardiac Life Support (ACLS) procedures and reflects necessary compromises between the realities of the operational environment and prompt provision of medical care. Results: Numerous changes were incorporated due to the diminution in available personnel, including substitution of endotracheal rather than intravenous delivery of drugs, more rapid defibrillation, addition of a precordial thump, removal of transcutaneous pacing, streamlining of procedural steps, and clarification of termination criteria. Discussion: The on-orbit care available to the ISS crewmembers is constrained by numerous factors, including crew medical training, minimal medical assets, limited air/ground communication , and a single caregiver for the foreseeable future. All of these combine to make a successful resuscitation unlikely, however, this procedure must ultimately deal with not only the patient's welfare, but also that of the caregiver, the mission, and the program.
Diabetic foot surgery: classifying patients to predict complications.
Bevilacqua, Nicholas J; Rogers, Lee C; Armstrong, David G
2008-01-01
The purpose of this article is to describe a classification of diabetic foot surgery performed in the absence of critical limb ischaemia. The basis of this classification is centred on three fundamental variables that are present in the assessment of risk and indication: (1) presence or absence of neuropathy (the loss of protective sensation); (2) presence or absence of an open wound; (3) presence or absence of acute limb-threatening infection. The conceptual framework for this classification is to define distinct classes of surgery in an order of theoretically increasing risk for high-level amputation. These include: Class I: elective diabetic foot surgery (procedures performed to treat a painful deformity in a patient without the loss of protective sensation); Class II: prophylactic (procedure performed to reduce the risk of ulceration or reulceration in a person with the loss of protective sensation but without an open wound); Class III: curative (procedure performed to assist in healing an open wound); and Class IV: emergency (procedure performed to limit the progression of acute infection). The presence of critical ischaemia in any of these classes of surgery should prompt a vascular evaluation to consider (1) the urgency of the procedure being considered and (2) possible revascularization prior to or temporally concomitant with the procedure. It is our hope that this system begins a dialogue amongst physicians and surgeons which can ultimately facilitate communication, enhance perspective, and improve care.
Mester, Petru; Bouvaist, Helene; Delarche, Nicolas; Bouisset, Frédéric; Abdellaoui, Mohamed; Petiteau, Pierre-Yves; Dubreuil, Olivier; Boueri, Ziad; Chettibi, Mohamed; Souteyrand, Géraud; Madiot, Hend; Belle, Loic
2017-07-20
The aim of this study was to ascertain whether a minimalist immediate mechanical intervention (MIMI) aiming to restore an optimal Thrombolysis In Myocardial Infarction (TIMI) flow in the culprit artery, followed ≥7 days later by a second percutaneous coronary intervention with intentional stenting, is safe in patients with ST-segment elevation myocardial infarction and large thrombotic burden. SUPER-MIMI was a prospective, observational trial conducted between January 2014 and April 2015 in 14 French centres. A total of 155 patients were enrolled. The pharmacological therapy was left to the operator's discretion. Eighty-one patients (52.3%) had glycoprotein IIb/IIIa inhibitors (GPI) initiated before the end of the first procedure. The median (interquartile range [IQR]) delay between the two procedures was eight (seven to 12) days. Infarct-related artery reocclusion between the two procedures (primary endpoint) occurred in two patients (1.3%), neither of whom received GPI treatment. TIMI flow was maintained or improved between the end of the first procedure and the beginning of the second procedure in all patients. Thrombotic burden and stenosis severity diminished significantly between the two procedures. Stents were ultimately implanted in 97 patients (62.6%). Deferred stenting (≥7 days) in patients with a high thrombus burden was safe on a background of GPI therapy.
ACHIEVING CONSISTENT DOPPLER MEASUREMENTS FROM SDO /HMI VECTOR FIELD INVERSIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuck, Peter W.; Antiochos, S. K.; Leka, K. D.
NASA’s Solar Dynamics Observatory is delivering vector magnetic field observations of the full solar disk with unprecedented temporal and spatial resolution; however, the satellite is in a highly inclined geosynchronous orbit. The relative spacecraft–Sun velocity varies by ±3 km s{sup −1} over a day, which introduces major orbital artifacts in the Helioseismic Magnetic Imager (HMI) data. We demonstrate that the orbital artifacts contaminate all spatial and temporal scales in the data. We describe a newly developed three-stage procedure for mitigating these artifacts in the Doppler data obtained from the Milne–Eddington inversions in the HMI pipeline. The procedure ultimately uses 32more » velocity-dependent coefficients to adjust 10 million pixels—a remarkably sparse correction model given the complexity of the orbital artifacts. This procedure was applied to full-disk images of AR 11084 to produce consistent Dopplergrams. The data adjustments reduce the power in the orbital artifacts by 31 dB. Furthermore, we analyze in detail the corrected images and show that our procedure greatly improves the temporal and spectral properties of the data without adding any new artifacts. We conclude that this new procedure makes a dramatic improvement in the consistency of the HMI data and in its usefulness for precision scientific studies.« less
Image registration: enabling technology for image guided surgery and therapy.
Sauer, Frank
2005-01-01
Imaging looks inside the patient's body, exposing the patient's anatomy beyond what is visible on the surface. Medical imaging has a very successful history for medical diagnosis. It also plays an increasingly important role as enabling technology for minimally invasive procedures. Interventional procedures (e.g. catheter based cardiac interventions) are traditionally supported by intra-procedure imaging (X-ray fluoro, ultrasound). There is realtime feedback, but the images provide limited information. Surgical procedures are traditionally supported with pre-operative images (CT, MR). The image quality can be very good; however, the link between images and patient has been lost. For both cases, image registration can play an essential role -augmenting intra-op images with pre-op images, and mapping pre-op images to the patient's body. We will present examples of both approaches from an application oriented perspective, covering electrophysiology, radiation therapy, and neuro-surgery. Ultimately, as the boundaries between interventional radiology and surgery are becoming blurry, also the different methods for image guidance will merge. Image guidance will draw upon a combination of pre-op and intra-op imaging together with magnetic or optical tracking systems, and enable precise minimally invasive procedures. The information is registered into a common coordinate system, and allows advanced methods for visualization such as augmented reality or advanced methods for therapy delivery such as robotics.
Two-stage distraction lengthening of the forearm.
Taghinia, Amir H; Al-Sheikh, Ayman A; Panossian, Andre E; Upton, Joseph
2013-01-01
Single-stage lengthening of the forearm using callus distraction is well described; however, forearm lengthening using a 2-stage technique of distraction followed by bone grafting has received less attention. A 2-staged technique can be a better alternative in cases where the surgeon desires extensive lengthening. A retrospective review was undertaken of eleven 2-stage forearm lengthening procedures performed by 1 surgeon over a 15-year period. Indications were radial longitudinal deficiency (8 patients), neonatal ischemic contractures (2 patients), and septic growth arrest (1 patient). Average follow-up was 2.8 years. Distraction was performed on patients an average of 82 mm over an average duration of 24 weeks. Average time to union from the time of distractor removal and grafting was 87 days. Average healing index was 32.1 d/cm. Distraction problems were common and related to the length of time that the distractor was in place; they included pain, pin-related infections, and multiple mechanical device difficulties. Three patients had nonunion, and another had delayed union; however, additional procedures resulted in ultimate bony union in all patients. Demineralized bone matrix and autologous corticocancellous bone grafts yielded predictable healing and good functional results in short-distance distractions. For longer distractions, free vascularized fibula transfer produced the best outcomes. Intercalary cortical allografts did not heal well. Patients with neonatal Volkmann contractures had the most difficulty with distraction and healing, ultimately obtaining little to no lengthening and poor functional outcomes.
Sabin, A B
1991-03-01
Poliomyelitis caused by polioviruses has already been eradicated from industrialized countries of North America, Europe, Asia and Oceania, but the procedures by which this eradication was achieved are not adequate for the poor tropical and subtropical countries. The major challenge now is first to eliminate it rapidly from Asia and Africa where an estimated 250,000 cases and 25,000 deaths currently occur annually. The great progress toward eradication of "wild" polioviruses from poor tropical and subtropical countries in Latin America was achieved not by the procedures still recommended by the WHO Expanded Program on Immunization (EPI) but by the independently organized annual, national days of antipolio vaccination - all based on the use of large armies of well-trained non-professional, community volunteers - first used in Cuba (1962), Brazil (1980), Nicaragua (1981), Dominican Republic (1983), Paraguay (1985), and Mexico (1986). This novel approach, described in some detail in this communication, is recommended for the rapid elimination of wild polioviruses from Asia and Africa, and for ultimate global eradication with the help of a special cadre within the EPI of WHO. The extensive use by the Pan American Health Organization (PAHO) of highly sophisticated regional virus laboratories has led to the recognition that, in areas from which poliomyelitis caused by polioviruses has been largely eliminated, there are thousands of cases of acute flaccid paralysis, previously clinically diagnosed as "probable poliomyelitis", that have no viral etiology, a phenomenon previously reported by Dr. Manuel Ramos Alvarez in Mexico City in 1967.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-06
... Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... for use as an alternative oil and grease method. Some comments were specific to the sampling...-side comparison using the specific procedures (e.g. sampling frequency, number of samples, QA/QC, and...
ERIC Educational Resources Information Center
Boyd, Aimee M.; Dodd, Barbara; Fitzpatrick, Steven
2013-01-01
This study compared several exposure control procedures for CAT systems based on the three-parameter logistic testlet response theory model (Wang, Bradlow, & Wainer, 2002) and Masters' (1982) partial credit model when applied to a pool consisting entirely of testlets. The exposure control procedures studied were the modified within 0.10 logits…
Comparison of Methods for Demonstrating Passage of Time When Using Computer-Based Video Prompting
ERIC Educational Resources Information Center
Mechling, Linda C.; Bryant, Kathryn J.; Spencer, Galen P.; Ayres, Kevin M.
2015-01-01
Two different video-based procedures for presenting the passage of time (how long a step lasts) were examined. The two procedures were presented within the framework of video prompting to promote independent multi-step task completion across four young adults with moderate intellectual disability. The two procedures demonstrating passage of the…
Comparison of alternative devices to determine aggregate shape.
DOT National Transportation Integrated Search
2005-01-01
This study compared devices (with corresponding procedures) that may be used to classify flat and elongated (F&E) particle content for coarse aggregate sources. The comparison involved the traditional (and manual) proportional caliper and two digital...
A Simple Illustration for the Need of Multiple Comparison Procedures
ERIC Educational Resources Information Center
Carter, Rickey E.
2010-01-01
Statistical adjustments to accommodate multiple comparisons are routinely covered in introductory statistical courses. The fundamental rationale for such adjustments, however, may not be readily understood. This article presents a simple illustration to help remedy this.
A COMPARISON OF INTRAVERBAL TRAINING PROCEDURES FOR CHILDREN WITH AUTISM
Kodak, Tiffany; Fuchtman, Rashea; Paden, Amber
2012-01-01
We compared the effectiveness of three training procedures, echoic and tact prompting plus error correction and a cues-pause-point (CPP) procedure, for increasing intraverbals in 2 children with autism. We also measured echoic behavior that may have interfered with appropriate question answering. Results indicated that echoic prompting with error correction was most effective and the CPP procedure was least effective for increasing intraverbals and decreasing echoic behavior. PMID:22403459
Applications of self-control procedures by children: a review.
O'Leary, S G; Dubey, D R
1979-01-01
Self-control procedures as used by children to affect their own behavior were reviewed. Particular emphasis was placed on self-instruction, self-determined criteria, self-assessment, and self-reinforcement. Self-punishment, comprehensive programs, and innovative self-control procedures (distraction and restatement of contingencies) were also evaluated. Basic effectiveness, comparisons with similar externally imposed interventions, maintenance, and the augmental value of the procedures were assessed. Important problems for future research were identified. PMID:389917
Global Perspective for Protecting Intellectual Property - Patenting in USA and Poland
NASA Astrophysics Data System (ADS)
Grebski, Michalene Eva; Wolniak, Radosław
2018-06-01
Paper addresses the different methods for protecting intellectual property in modern knowledge-based economies. The focus of the paper is a comparison between the procedures for applying for patents in Poland and the United States. The comparison has been made from the perspective of the cost of obtaining and maintaining a patent in Poland, the United States and some other countries. The comparison has also been made from the perspective of the procedures for applying for a patent in different countries based on the Patent Cooperation Treaty. The paper also includes a comparison of the time needed for processing the patent application. Low cost provisional twelve-month patent pending protection available in the United States is also being discussed. The paper also provides some guidance and recommendations for conducting a patent search in order to validate the originality of the invention.
State-of-the-art and emerging technologies for atrial fibrillation ablation.
Dewire, Jane; Calkins, Hugh
2010-03-01
Catheter ablation is an important treatment modality for patients with atrial fibrillation (AF). Although the superiority of catheter ablation over antiarrhythmic drug therapy has been demonstrated in middle-aged patients with paroxysmal AF, the role the procedure in other patient subgroups-particularly those with long-standing persistent AF-has not been well defined. Furthermore, although AF ablation can be performed with reasonable efficacy and safety by experienced operators, long-term success rates for single procedures are suboptimal. Fortunately, extensive ongoing research will improve our understanding of the mechanisms of AF, and considerable funds are being invested in developing new ablation technologies to improve patient outcomes. These technologies include ablation catheters designed to electrically isolate the pulmonary veins with improved safety, efficacy, and speed, catheters designed to deliver radiofrequency energy with improved precision, robotic systems to address the technological demands of the procedure, improved imaging and electrical mapping systems, and MRI-guided ablation strategies. The tools, technologies, and techniques that will ultimately stand the test of time and become the standard approach to AF ablation in the future remain unclear. However, technological advances are sure to result in the necessary improvements in the safety and efficacy of AF ablation procedures.
Crouse, C A; Ban, J D; D'Alessio, J K
1993-10-01
Sonication procedures for the extraction of DNA from forensic-type semen specimens have been developed, which, when compared to currently utilized sperm DNA extraction techniques, are simple, rapid and result in comparable DNA yields. Sperm DNA extraction by sonication was performed on whole semen, seminal stains, buccal swabs and post-coital specimens. Ultrasound disruption of sperm cells and their ultimate release of cellular DNA has been conducted in the presence of sperm wash buffers followed by organic extraction or Chelex 100 with little or no compromise to DNA quality, quantity or amplifiability. Two advantages of sonication over currently used forensic techniques to extract sperm DNA include 1) sperm DNA extraction that occurs within five minutes of sonication compared with an hour or greater for water bath incubations in classic enzyme digestion DNA extractions and 2) one less preparatory step with the Chelex/sonication protocol and three less steps with the sonication/organic protocol compared with other procedures thus eliminating potential sample-to-sample cross-contamination. Sperm DNA extracted by optimum sonication procedures was used for forensic HLA DQ alpha typing and restriction fragment length polymorphisms analysis without any adverse effects on typing results.
1981-09-01
organized the paperwork system , including finances, travel, k, , f iling, and programs in a highly independent and responsible fashion. Thanks are also due...three-dimensional transformation procedure for arbitrary non-orthogonal coordinate systems , for the purpose of the three-dimensional turbulent...transformation procedure for arbitrary non-orthogonal coordinate systems so as to acquire the generality in the application for elliptic flows (for the square
Comparison of thruster configurations in attitude control systems. M.S. Thesis. Progress Report
NASA Technical Reports Server (NTRS)
Boland, J. S., III; Drinkard, D. M., Jr.; White, L. R.; Chakravarthi, K. R.
1973-01-01
Several aspects concerning reaction control jet systems as used to govern the attitude of a spacecraft were considered. A thruster configuration currently in use was compared to several new configurations developed in this study. The method of determining the error signals which control the firing of the thrusters was also investigated. The current error determination procedure is explained and a new method is presented. Both of these procedures are applied to each of the thruster configurations which are developed and comparisons of the two methods are made.
van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W
2016-07-01
Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.
Practical issues in quantum-key-distribution postprocessing
NASA Astrophysics Data System (ADS)
Fung, Chi-Hang Fred; Ma, Xiongfeng; Chau, H. F.
2010-01-01
Quantum key distribution (QKD) is a secure key generation method between two distant parties by wisely exploiting properties of quantum mechanics. In QKD, experimental measurement outcomes on quantum states are transformed by the two parties to a secret key. This transformation is composed of many logical steps (as guided by security proofs), which together will ultimately determine the length of the final secret key and its security. We detail the procedure for performing such classical postprocessing taking into account practical concerns (including the finite-size effect and authentication and encryption for classical communications). This procedure is directly applicable to realistic QKD experiments and thus serves as a recipe that specifies what postprocessing operations are needed and what the security level is for certain lengths of the keys. Our result is applicable to the BB84 protocol with a single or entangled photon source.
Afreen, Mahrukh; Ansari, Murtaza Ahsan
2015-12-01
Endotracheal intubation plays a key role in the management of upper airway obstruction in emergency situations. It is non-invasive and easily learned technique by medical professionals as compared to other more skilled, surgical procedures, e.g., tracheostomy and cricothyrotomies etc. But prolonged intubation may result in numerous complications, most notorious being tracheoesophageal fistula and narrowing of subglottic area. We report a profile of a patient who had been diagnosed as case of Guillian-Barre Syndrome, had difficulty in breathing due to paralysis of respiratory muscles. The patient was admitted in Medical Intensive Care Unit (MICU) for 40 days and was kept on artificial breathing through endotracheal intubation, which remained in place for 19 days. Later tracheostomy was performed. Patient ultimately developed severe subglottic stenosis and became dependent on tracheostomy tube.
Leone Roberti Maggiore, Umberto; Bogani, Giorgio; Meschia, Michele; Sorice, Paola; Braga, Andrea; Salvatore, Stefano; Ghezzi, Fabio; Serati, Maurizio
2015-06-01
Bulking agents provide an alternative option in the management of women with stress urinary incontinence and they seem to have an important role in the management flow chart of SUI. However, evidence on this issue is scanty. The most important aspect is to understand whether bulking agents are comparable with the other first-line anti-incontinence surgical procedure (MUS, Burch colposuspension and pubovaginal slings). Hence, the primary aim of the current review was to assess the objective and subjective outcomes of bulking agents in comparison with the other surgical procedures for the treatment of SUI. PubMed and Medline were systematically searched and we included studies evaluating the use of bulking agents in comparison with other surgical approaches for either primary or recurrent treatment of female SUI. Three studies meeting the inclusion criteria were identified. Two of these studies were RCTs evaluating the use of bulking agents versus other surgical procedures for the treatment of primary female SUI; the remnant article was a retrospective cohort study that compared the effectiveness and safety of repeat midurethral sling with urethral bulking after failed midurethral sling. The combined results of all analyses showed that the objective recurrence rate of peri- or trans-urethral injections is significantly higher in comparison with the other surgical procedures. Similar findings were observed when considering separately the treatment for primary or recurrent SUI. Furthermore, lower subjective recurrence rate was observed among patients undergoing other surgical treatment in comparison with those undergoing bulking agents; however, this trend was not statistically significant. Moreover, patients undergoing injection of bulking agents experienced a lower rate of voiding dysfunctions in comparison to the control group. According to current evidence, bulking agents should not be proposed as first-line treatment in those women seeking permanent cure for both primary and recurrent SUI. However, the effectiveness of a procedure should be balanced with its invasiveness and patients' expectations. Bulking agents are a minimally invasive approach to treat SUI and their use should be considered as an alternative strategy particularly in special conditions: patients who are fragile, in those who do not wish to have surgery, or in whom surgical options are restricted (postoperatively, after irradiation). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Asynchronous Transfer Mode (ATM) Switch Technology and Vendor Survey
NASA Technical Reports Server (NTRS)
Berry, Noemi
1995-01-01
Asynchronous Transfer Mode (ATM) switch and software features are described and compared in order to make switch comparisons meaningful. An ATM switch's performance cannot be measured solely based on its claimed switching capacity; traffic management and congestion control are emerging as the determining factors in an ATM network's ultimate throughput. Non-switch ATM products and experiences with actual installations of ATM networks are described. A compilation of select vendor offerings as of October 1994 is provided in chart form.
A Visual Evaluation Study of Graph Sampling Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Fangyan; Zhang, Song; Wong, Pak C.
2017-01-29
We evaluate a dozen prevailing graph-sampling techniques with an ultimate goal to better visualize and understand big and complex graphs that exhibit different properties and structures. The evaluation uses eight benchmark datasets with four different graph types collected from Stanford Network Analysis Platform and NetworkX to give a comprehensive comparison of various types of graphs. The study provides a practical guideline for visualizing big graphs of different sizes and structures. The paper discusses results and important observations from the study.
Parsing English. Course Notes for a Tutorial on Computational Semantics, March 17-22, 1975.
ERIC Educational Resources Information Center
Wilks, Yorick
The course in parsing English is essentially a survey and comparison of several of the principal systems used for understanding natural language. The basic procedure of parsing is described. The discussion of the principal systems is based on the idea that "meaning is procedures," that is, that the procedures of application give a parsed…
The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped for further analysis. This procedure applies to the checking of food samples and shipment ...
NASA Technical Reports Server (NTRS)
Gossard, Myron L
1952-01-01
An iterative transformation procedure suggested by H. Wielandt for numerical solution of flutter and similar characteristic-value problems is presented. Application of this procedure to ordinary natural-vibration problems and to flutter problems is shown by numerical examples. Comparisons of computed results with experimental values and with results obtained by other methods of analysis are made.
ERIC Educational Resources Information Center
Lubke, Gitta; Tueller, Stephen
2010-01-01
Taxometric procedures such as MAXEIG and factor mixture modeling (FMM) are used in latent class clustering, but they have very different sets of strengths and weaknesses. Taxometric procedures, popular in psychiatric and psychopathology applications, do not rely on distributional assumptions. Their sole purpose is to detect the presence of latent…
The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped to the FDA for further analysis. This procedure applies to the checking of food samples an...
Bachmann, Peter
2008-07-01
The Mutual Recognition Procedure (MRP) and the Decentralised Procedure (DCP), which were first established in late 2005, can be regarded as the backbone for marketing authorisation of medicinal products in the European Community (EC) and the European Economic Area (EEA). Both procedures are compared and advantages and disadvantages are discussed. However, the focus is more related to current developments than the detailed comparison of both procedures. The role of the Coordination Group for Mutual Recognition and Decentralised Procedures-Human (CMD(h)) and the decision making process in relation to the MRP and DCP is also discussed.
Special Issue of Solid-State Electronics, dedicated to EUROSOI-ULIS 2016
NASA Astrophysics Data System (ADS)
Sverdlov, Viktor; Selberherr, Siegfried
2017-02-01
The current special issue of Solid-State Electronics includes 29 extended papers presented at the 2016 Second Joint International EUROSOI Workshop and International Conference on Ultimate Integration on Silicon (EUROSOI-ULIS 2016) held in Wien, Austria, on January 25-27, 2016. The papers entering to the special issue have been selected by the EUROSOI-ULIS 2016 Technical Program Committee based on the excellence of abstracts submitted and presentations delivered at the conference. In order to comply with the high standards of Solid-State Electronics the manuscripts went through the standard reviewing procedure.
Echocardiographic identification of ventricular septal rupture caused by acute stent thrombosis.
Garg, Scot; Bourantas, Christos V; Thackray, Simon; Alamgir, Mohamed F
2010-05-01
Coronary stenting is an increasingly common procedure. Complications are rare. However, when they do occur, they often require urgent invasive treatment. Investigations that are critical for establishing a diagnosis as well as such guide treatment as a detailed assessment of myocardial morphology and function using transthoracic echocardiography may be overlooked in the haste to treat the patient. We present a case report of subacute drug-eluting stent thrombosis in which a meticulous echocardiographic examination allowed the identification of a ventricular septal rupture, which ultimately modified treatment.
WCRP surface radiation budget shortwave data product description, version 1.1
NASA Technical Reports Server (NTRS)
Whitlock, C. H.; Charlock, T. P.; Staylor, W. F.; Pinker, R. T.; Laszlo, I.; Dipasquale, R. C.; Ritchey, N. A.
1993-01-01
Shortwave radiative fluxes which reach the Earth's surface are key elements that influence both atmospheric and oceanic circulation. The World Climate Research Program has established the Surface Radiation Budget climatology project with the ultimate goal of determining the various components of the surface radiation budget from satellite data on a global scale. This report describes the first global product that is being produced and archived as part of that effort. The interested user can obtain the monthly global data sets free of charge using e-mail procedures.
Surgeon and type of anesthesia predict variability in surgical procedure times.
Strum, D P; Sampson, A R; May, J H; Vargas, L G
2000-05-01
Variability in surgical procedure times increases the cost of healthcare delivery by increasing both the underutilization and overutilization of expensive surgical resources. To reduce variability in surgical procedure times, we must identify and study its sources. Our data set consisted of all surgeries performed over a 7-yr period at a large teaching hospital, resulting in 46,322 surgical cases. To study factors associated with variability in surgical procedure times, data mining techniques were used to segment and focus the data so that the analyses would be both technically and intellectually feasible. The data were subdivided into 40 representative segments of manageable size and variability based on headers adopted from the common procedural terminology classification. Each data segment was then analyzed using a main-effects linear model to identify and quantify specific sources of variability in surgical procedure times. The single most important source of variability in surgical procedure times was surgeon effect. Type of anesthesia, age, gender, and American Society of Anesthesiologists risk class were additional sources of variability. Intrinsic case-specific variability, unexplained by any of the preceding factors, was found to be highest for shorter surgeries relative to longer procedures. Variability in procedure times among surgeons was a multiplicative function (proportionate to time) of surgical time and total procedure time, such that as procedure times increased, variability in surgeons' surgical time increased proportionately. Surgeon-specific variability should be considered when building scheduling heuristics for longer surgeries. Results concerning variability in surgical procedure times due to factors such as type of anesthesia, age, gender, and American Society of Anesthesiologists risk class may be extrapolated to scheduling in other institutions, although specifics on individual surgeons may not. This research identifies factors associated with variability in surgical procedure times, knowledge of which may ultimately be used to improve surgical scheduling and operating room utilization.
The Comparison of Thyroarytenoid Muscle Myectomy and Type II Thyroplasty for Spasmodic Dysphonia.
Nomoto, Masaki; Tokashiki, Ryoji; Hiramatsu, Hiroyuki; Konomi, Ujimoto; Motohashi, Rei; Sakurai, Eriko; Toyomura, Fumimasa; Ueda, Yuri; Inoue, Shun; Tsukahara, Kiyoaki; Suzuki, Mamoru
2015-07-01
Surgical treatments for adductor spasmodic dysphonia include bilateral thyroarytenoid muscle myectomy (TAM) and type II thyroplasty (TPII), both of which are commonly performed. The present study aimed to compare the effects of TAM and TPII. Retrospective study. Subjects were 30 and 35 patients who underwent TAM and TPII, between March 2008 and November 2012. Voice quality was evaluated based on "voice handicap index 10 (VHI10)" and auditory impressions before and 6 months after surgery using five parameters: "strangulation," "interruption," "tremor," "grade," and "breathiness." Comparison of the two procedures revealed significant improvements in VHI10, strangulation, interruption, and tremor, and a significant decline in breathiness after surgery. In particular, VHI10 was improved by more than six points in 90% of patients with TAM, and 96% with TPII. No significant difference was observed between the severities of two procedures preoperatively. Comparison of each postoperative score between the two procedures revealed that TAM significantly improved strangulation, interruption, and tremor, and significantly worsened breathiness, with no significant difference in VHI10. Scatter plots (x: preoperative scores; y: postoperative scores) and regression lines of evaluation items demonstrated that TAM is more effective than TPII in severe cases. Compared with TPII, TAM tends to improve strangulation, interruption, and tremor; however, it tends to worsen breathiness postoperatively. Postoperative VHI10 scores did not differ significantly between the two procedures. Given favorable improvement rates, both surgical procedures were considered effective. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
The Gibson and Piggott osteotomy for adult hallux valgus.
Rangrez, Arshad Bashir; Dar, Tahir Ahmed; Badoo, Abdul Rashid; Wani, Sharief Ahmed; Dhar, Shabir Ahmed; Mumtaz, Imran; Ahmed, Muzzaffar
2012-01-01
The Gibson and Piggott procedure for hallux valgus is based on sound surgical principles addressing the basic pathologies of this disorder. However, this procedure has not been studied extensively in the literature in comparison to the Mitchell and Chevron osteotomies. We report a prospective study conducted on 50 adult feet with hallux valgus. The Gibson and Piggot osteotomy was done on all the feet. We obtained 76% excellent and 18% good results with this procedure. The results bear out the fact that this procedure is a useful procedure for the management of this disorder.
Consensus building for interlaboratory studies, key comparisons, and meta-analysis
NASA Astrophysics Data System (ADS)
Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza
2017-06-01
Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian procedure; and the Linear Pool. These three procedures have been implemented and made widely accessible in a Web-based application (NIST Consensus Builder). We illustrate principles, statistical models, and data reduction procedures in four examples: (i) the measurement of the Newtonian constant of gravitation; (ii) the measurement of the half-lives of radioactive isotopes of caesium and strontium; (iii) the comparison of two alternative treatments for carotid artery stenosis; and (iv) a key comparison where the measurand was the calibration factor of a radio-frequency power sensor.
The drive to eat: comparisons and distinctions between mechanisms of food reward and drug addiction.
DiLeone, Ralph J; Taylor, Jane R; Picciotto, Marina R
2012-10-01
The growing rates of obesity have prompted comparisons between the uncontrolled intake of food and drugs; however, an evaluation of the equivalence of food- and drug-related behaviors requires a thorough understanding of the underlying neural circuits driving each behavior. Although it has been attractive to borrow neurobiological concepts from addiction to explore compulsive food seeking, a more integrated model is needed to understand how food and drugs differ in their ability to drive behavior. In this Review, we will examine the commonalities and differences in the systems-level and behavioral responses to food and to drugs of abuse, with the goal of identifying areas of research that would address gaps in our understanding and ultimately identify new treatments for obesity or drug addiction.
Frequency transfer via a two-way optical phase comparison on a multiplexed fiber network.
Calosso, C E; Bertacco, E; Calonico, D; Clivati, C; Costanzo, G A; Frittelli, M; Levi, F; Mura, A; Godone, A
2014-03-01
We performed a two-way remote optical phase comparison on optical fiber. Two optical frequency signals were launched in opposite directions in an optical fiber and their phases were simultaneously measured at the other end. In this technique, the fiber noise is passively canceled, and we compared two optical frequencies at the ultimate 10(-21) stability level. The experiment was performed on a 47 km fiber that is part of the metropolitan network for Internet traffic. The technique relies on the synchronous measurement of the optical phases at the two ends of the link, which is here performed by digital electronics. This scheme offers some advantages with respect to active noise cancellation schemes, as the light travels only once in the fiber.
Williams, G E; Cuvo, A J
1986-01-01
The research was designed to validate procedures to teach apartment upkeep skills to severely handicapped clients with various categorical disabilities. Methodological features of this research included performance comparisons between general and specific task analyses, effect of an impasse correction baseline procedure, social validation of training goals, natural environment assessments and contingencies, as well as long-term follow-up. Subjects were taught to perform upkeep responses on their air conditioner-heating unit, electric range, refrigerator, and electrical appliances within the context of a multiple-probe across subjects experimental design. The results showed acquisition, long-term maintenance, and generalization of the upkeep skills to a nontraining apartment. General task analyses were recommended for assessment and specific task analyses for training. The impasse correction procedure generally did not produce acquisition. PMID:3710947
Sandhu, Gurkirat; Khinda, Paramjit Kaur; Gill, Amarjit Singh; Singh Khinda, Vineet Inder; Baghi, Kamal; Chahal, Gurparkash Singh
2017-01-01
Periodontal surgical procedures produce varying degree of stress in all patients. Nitrous oxide-oxygen inhalation sedation is very effective for adult patients with mild-to-moderate anxiety due to dental procedures and needle phobia. The present study was designed to perform periodontal surgical procedures under nitrous oxide-oxygen inhalation sedation and assess whether this technique actually reduces stress physiologically, in comparison to local anesthesia alone (LA) during lengthy periodontal surgical procedures. This was a randomized, split-mouth, cross-over study. A total of 16 patients were selected for this randomized, split-mouth, cross-over study. One surgical session (SS) was performed under local anesthesia aided by nitrous oxide-oxygen inhalation sedation, and the other SS was performed on the contralateral quadrant under LA. For each session, blood samples to measure and evaluate serum cortisol levels were obtained, and vital parameters including blood pressure, heart rate, respiratory rate, and arterial blood oxygen saturation were monitored before, during, and after periodontal surgical procedures. Paired t -test and repeated measure ANOVA. The findings of the present study revealed a statistically significant decrease in serum cortisol levels, blood pressure and pulse rate and a statistically significant increase in respiratory rate and arterial blood oxygen saturation during periodontal surgical procedures under nitrous oxide inhalation sedation. Nitrous oxide-oxygen inhalation sedation for periodontal surgical procedures is capable of reducing stress physiologically, in comparison to LA during lengthy periodontal surgical procedures.
Comparison of "saw and seal" procedure and performance grade binder to minimize thermal cracking.
DOT National Transportation Integrated Search
2001-04-01
In an effort to compare performance and cost effectiveness of the Saw and : Seal procedure and Performance Grade (PG) binders, the Maine Department Of : Transportation (MDOT) constructed an experimental project in Weston, Maine : during the fal...
7 CFR 1486.303 - What specific contracting procedures must be adhered to?
Code of Federal Regulations, 2010 CFR
2010-01-01
... MARKETS PROGRAM Program Operations § 1486.303 What specific contracting procedures must be adhered to? (a...) Perform some form of fee, price, or cost analysis, such as a comparison of price quotations to market...) Document the decision-making process. ...
2012-01-01
Background The NCBI Conserved Domain Database (CDD) consists of a collection of multiple sequence alignments of protein domains that are at various stages of being manually curated into evolutionary hierarchies based on conserved and divergent sequence and structural features. These domain models are annotated to provide insights into the relationships between sequence, structure and function via web-based BLAST searches. Results Here we automate the generation of conserved domain (CD) hierarchies using a combination of heuristic and Markov chain Monte Carlo (MCMC) sampling procedures and starting from a (typically very large) multiple sequence alignment. This procedure relies on statistical criteria to define each hierarchy based on the conserved and divergent sequence patterns associated with protein functional-specialization. At the same time this facilitates the sequence and structural annotation of residues that are functionally important. These statistical criteria also provide a means to objectively assess the quality of CD hierarchies, a non-trivial task considering that the protein subgroups are often very distantly related—a situation in which standard phylogenetic methods can be unreliable. Our aim here is to automatically generate (typically sub-optimal) hierarchies that, based on statistical criteria and visual comparisons, are comparable to manually curated hierarchies; this serves as the first step toward the ultimate goal of obtaining optimal hierarchical classifications. A plot of runtimes for the most time-intensive (non-parallelizable) part of the algorithm indicates a nearly linear time complexity so that, even for the extremely large Rossmann fold protein class, results were obtained in about a day. Conclusions This approach automates the rapid creation of protein domain hierarchies and thus will eliminate one of the most time consuming aspects of conserved domain database curation. At the same time, it also facilitates protein domain annotation by identifying those pattern residues that most distinguish each protein domain subgroup from other related subgroups. PMID:22726767
Advanced performance of small diaphragm vacuum pumps through the use of mechatronics
NASA Astrophysics Data System (ADS)
Lachenmann, R.; Dirscherl, J.
Oil-free diaphragm vacuum pumps have proven to be the best way in vacuum generation for the chemical laboratory and they also find increasing use as backing pumps for modern wide-range turbo molecular pumps. The majority of vacuum pumps in practical use pump only a rather small percentage of their lifetime at full gas load. A pump backing a turbo molecular pump does not have to pump a significant gas load when the high-vacuum pump is running at ultimate vacuum pressure. Also, for a vacuum distillation the vacuum pump has to operate at full speed only at the beginning to lower the pressure inside the system to a vacuum level where evaporation starts. In a rather leak-tight system the distillation process continues by evaporating from the hot liquid and condensing at the cold condenser without the need of a mechanical vacuum pump. Rotational speed controlled diaphragm pumps are now available through progress in mechatronics and offer high pumping speed capability for fast pump-down cycles and precise pressure control for distillations. At low gas load the rotational speed can be reduced, improving maintenance intervals, power consumption, noise, vibration and - surprisingly - also ultimate pressure. The different behaviour in pumping speed and ultimate pressure of rotational speed controlled diaphragm pumps in comparison to constant-speed pumps is related to the mechanical properties of the valves and gas dynamics .
2017-04-01
A COMPARISON OF PREDICTIVE THERMO AND WATER SOLVATION PROPERTY PREDICTION TOOLS AND EXPERIMENTAL DATA FOR...4. TITLE AND SUBTITLE A Comparison of Predictive Thermo and Water Solvation Property Prediction Tools and Experimental Data for Selected...1 2. EXPERIMENTAL PROCEDURE
van Steenbergen, Liza N; Spooren, Anneke; van Rooden, Stephanie M; van Oosterhout, Frank J; Morrenhof, Jan W; Nelissen, Rob G H H
2015-01-01
Background and purpose A complete and correct national arthroplasty register is indispensable for the quality of arthroplasty outcome studies. We evaluated the coverage, completeness, and validity of the Dutch Arthroplasty Register (LROI) for hip and knee arthroplasty. Patients and methods The LROI is a nationwide population-based registry with information on joint arthroplasties in the Netherlands. Completeness of entered procedures was validated in 2 ways: (1) by comparison with the number of reimbursements for arthroplasty surgeries (Vektis database), and (2) by comparison with data from hospital information systems (HISs). The validity was examined by conducting checks on missing or incorrectly coded values in the LROI. Results The LROI contains over 300,000 hip and knee arthroplasties performed since 2007. Coverage of all Dutch hospitals (n = 100) was reached in 2012. Completeness of registered procedures was 98% for hip arthroplasty and 96% for knee arthroplasty in 2012, based on Vektis data. Based on comparison with data from the HIS, completeness of registered procedures was 97% for primary total hip arthroplasty and 96% for primary knee arthroplasty in 2013. Completeness of revision arthroplasty was 88% for hips and 90% for knees in 2013. The proportion of missing or incorrectly coded values of variables was generally less than 0.5%, except for encrypted personal identity numbers (17% of which were missing) and ASA scores (10% of which were missing). Interpretation The LROI now contains over 300,000 hip and knee arthroplasty procedures, with coverage of all hospitals. It has a good level of completeness (i.e. more than 95% for primary hip and knee arthroplasty procedures in 2012 and 2013) and the database has high validity. PMID:25758646
Loftin, Keith A.; Meyer, Michael T.; Rubio, Fernando; Kamp, Lisa; Humphries, Edythe; Whereat, Ed
2008-01-01
A collaboration was developed between Abraxis, LLC, the State of Delaware Department of Natural Resources and Environmental Control Division of Water Resources Environmental Laboratory, the University of Delaware, and the United States Geological Survey to investigate the efficacy of the QuikLyse procedure developed by Abraxis, LLC as an alternative cell-lysis technique suitable for use with an existing liquid chromatography/tandem mass spectrometry research method developed at the United States Geological Survey Organic Geochemistry Research Laboratory to analyze cyanotoxins. A comparison of three sequential freeze/thaw cycles versus QuikLyse, a proprietary chemical lysis procedure was conducted on four water samples collected from Silver Lake in Dover, Delaware. Results from the Abraxis Microcystins-DM enzyme-linked immunosorbent assay and liquid chromatography/tandem mass spectrometry were tabulated as a function of the cell lysis technique. Stastical comparison of percent relative standard deviations showed no significant difference (alpha = 0.05) between both cell-lysis techniques when measured by enzyme-linked immunosorbent assay or liquid chromatography/tandem mass spectrometry for three of the four samples.
ERIC Educational Resources Information Center
McKerchar, Todd L.; Zarcone, Troy J.; Fowler, Stephen C.
2005-01-01
Recent progress in mouse genetics has led to an increased interest in developing procedures for assessing mouse behavior, but relatively few of the behavioral procedures developed involve positively reinforced operant behavior. When operant methods are used, nose poking, not lever pressing, is the target response. In the current study differential…
Model Comparison of Nonlinear Structural Equation Models with Fixed Covariates.
ERIC Educational Resources Information Center
Lee, Sik-Yum; Song, Xin-Yuan
2003-01-01
Proposed a new nonlinear structural equation model with fixed covariates to deal with some complicated substantive theory and developed a Bayesian path sampling procedure for model comparison. Illustrated the approach with an illustrative example using data from an international study. (SLD)
40 CFR 761.323 - Sample preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROHIBITIONS Self-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... of use in this chemical extraction and chemical analysis comparison study, a person may adjust PCB...
DOT National Transportation Integrated Search
2002-06-01
In an effort to compare performance and cost effectiveness of the Saw and Seal procedure and : Performance Grade (PG) binders, the Maine Department of Transportation (MDOT) constructed an : experimental project in Weston, Maine during the fall ...
DEVELOPMENT OF A PROTOCOL FOR TESTING EFFECTS OF TOXIC SUBSTANCES ON PLANTS
This study was designed to devise a rapid, simple, reproducible bioassay procedure to determine effects of so-called 'toxic substances in the environment' on vegetation and provide a standardized procedure for evaluation and comparison of effects of diverse compounds. Eight diffe...
Richman, David M; Grubb, Laura; Thompson, Samuel
2018-01-01
Strategic Incremental Rehearsal (SIR) is an effective method for teaching sight-word acquisition, but has neither been evaluated for use in adults with an intellectual disability, nor directly compared to the ongoing instruction in the natural environment. Experimental analysis of sight word acquisition via an alternating treatment design was conducted with a 23-year-old woman with Down syndrome. SIR was compared to the current reading instruction (CRI) in a classroom for young adults with intellectual disabilities. CRI procedures included non-contingent praise, receptive touch prompts ("touch the word bat"), echoic prompts ("say bat"), textual prompts ("read the word"), and pre-determined introduction of new words. SIR procedures included textual prompts on flash cards, contingent praise, corrective feedback, and mastery-based introduction of new words. The results indicated that SIR was associated with more rapid acquisition of sight words than CRI. Directions for future research could include systematic comparisons to other procedures, and evaluations of procedural permutations of SIR.
Auditory phase and frequency discrimination: a comparison of nine procedures.
Creelman, C D; Macmillan, N A
1979-02-01
Two auditory discrimination tasks were thoroughly investigated: discrimination of frequency differences from a sinusoidal signal of 200 Hz and discrimination of differences in relative phase of mixed sinusoids of 200 Hz and 400 Hz. For each task psychometric functions were constructed for three observers, using nine different psychophysical measurement procedures. These procedures included yes-no, two-interval forced-choice, and various fixed- and variable-standard designs that investigators have used in recent years. The data showed wide ranges of apparent sensitivity. For frequency discrimination, models derived from signal detection theory for each psychophysical procedure seem to account for the performance differences. For phase discrimination the models do not account for the data. We conclude that for some discriminative continua the assumptions of signal detection theory are appropriate, and underlying sensitivity may be derived from raw data by appropriate transformations. For other continua the models of signal detection theory are probably inappropriate; we speculate that phase might be discriminable only on the basis of comparison or change and suggest some tests of our hypothesis.
NASA Astrophysics Data System (ADS)
Ceschini, L.; Morri, Alessandro; Morri, Andrea
2017-05-01
The aim of this research was to investigate the effects of casting size (10-210 mm) on the microstructure and mechanical properties of spheroidal (SGI) and compacted (CGI) graphite cast irons. A comparison of the experimental mechanical data with those specified by ISO standards is presented and discussed. The study highlighted that the microstructure and mechanical properties of SGI (also known as ductile or nodular cast iron) are more sensitive to casting size than CGI (also known as vermicular graphite cast irons). In particular, in both types of cast iron, hardness, yield strength and ultimate tensile strength decreased, with increasing casting size, by 27% in SGI and 17% in CGI. Elongation to failure showed, instead, an opposite trend, decreasing from 5 to 3% in CGI, while increasing from 5 to 11% in SGI. These results were related to different microstructures, the ferritic fraction being more sensitive to the casting size in SGI than CGI. Degeneration of spheroidal graphite was observed at casting size above 120 mm. The microstructural similarities between degenerated SGI and CGI suggested the proposal of a unified empirical constitutional law relating the most important microstructural parameters to the ultimate tensile strength. An outstanding result was also the finding that standard specifications underestimated the mechanical properties of both cast irons (in particular SGI) and, moreover, did not take into account their variation with casting size, at thicknesses over 60 mm.
Using Gagne's theory to teach procedural skills.
Buscombe, Charlotte
2013-10-01
Many key medical procedures are performed every day in clinical practice to yield important diagnostic information and to help determine the disease response to intensive treatments. Training clinicians to perform procedures competently and confidently thus carries considerable weight, helping to assure patient safety, the obtainment of adequate samples and minimising patient discomfort. This article considers how Robert Gagne's instructional design model may be effectively used to design lesson plans and teach procedural skills in small group settings. Gagne's model is based upon the information-processing model of mental events that occur when adults are presented with various stimuli. It highlights nine specific instructional events, which correlate with crucial conditions of learning, and are arranged to maximally enhance the learning process, improve session flow and, ultimately, ensure lesson objectives are comprehensively addressed. This article uses the nine points described by Gagne to outline a comprehensive lesson guide for teaching psychomotor skills, using a bone-marrow aspirate procedure as an example. Each of Gagne's instructional events is considered with specific activities for each, and with the variety of activities delineated to meet diverse learning styles. Gagne's instructional events can produce an effective and comprehensive lesson plan for teaching procedural skills, preparing learners with various preferred learning styles to perform psychomotor skills competently in clinical practice. This lesson plan can be of use for both teachers and students across clinical specialties, encouragingly outlining how Gagne's systematic and widely referenced theory can be creatively and practically used. © 2013 John Wiley & Sons Ltd.
Anaesthesia in outer space: the ultimate ambulatory setting?
Komorowski, Matthieu; Fleming, Sarah; Hinkelbein, Jochen
2016-12-01
Missions to the Moon or more distant planets are planned in the next future, and will push back the limits of our experience in providing medical support in remote environments. Medical preparedness is ongoing, and involves planning for emergency surgical interventions and anaesthetic procedures. This review will summarize what principles of ambulatory anaesthesia on Earth could benefit the environment of a space mission with its unique constraints. Ambulatory anaesthesia relies on several principles such as improved patient pathway, correct patient selection, optimized procedural strategies to hasten recovery and active prevention of postoperative complications. Severe limitations in the equipment available and the skills of the crew members represent the key factors to be taken into account when designing the on-board medical system for future interplanetary space missions. The application of some of the key principles of ambulatory anaesthesia, as well as recent advances in anaesthetic techniques and better understanding of human adaptation to the space environment might allow nonanaesthesiologist physicians to perform common anaesthetic procedures, whilst maximizing crew safety and minimizing the impact of medical events on the mission.
Vector ecology and integrated control procedures
Laird, Marshall
1963-01-01
The elucidation of population regulatory mechanisms calls for exhaustive biological and ecological studies of whole ecosystems. Until lately, little effort was made to relate insect control activities to such a background, and the use of non-selective pesticides has often resulted in biotic equilibria being disrupted to the ultimate advantage of the organism under attack or of some other undesirable species. However, there is a growing realization in the field of economic entomology at large that biotic control agents usually constitute the major portion of the environmental resistance to increases in pest numbers and that insecticides should be fitted into the ecosystem, and not imposed upon it—in fact, that integrated control procedures are called for. The author considers such integrated procedures from the standpoint of vector control. His paper points out their potentialities in helping to solve resistance problems and in increasing the selectivity of control operations. It further suggests that they offer the means of achieving economical and lasting reductions of vector populations to levels at which human disease transmission is interrupted and pest problems lose much of their importance. PMID:20604165
Optimization applications in aircraft engine design and test
NASA Technical Reports Server (NTRS)
Pratt, T. K.
1984-01-01
Starting with the NASA-sponsored STAEBL program, optimization methods based primarily upon the versatile program COPES/CONMIN were introduced over the past few years to a broad spectrum of engineering problems in structural optimization, engine design, engine test, and more recently, manufacturing processes. By automating design and testing processes, many repetitive and costly trade-off studies have been replaced by optimization procedures. Rather than taking engineers and designers out of the loop, optimization has, in fact, put them more in control by providing sophisticated search techniques. The ultimate decision whether to accept or reject an optimal feasible design still rests with the analyst. Feedback obtained from this decision process has been invaluable since it can be incorporated into the optimization procedure to make it more intelligent. On several occasions, optimization procedures have produced novel designs, such as the nonsymmetric placement of rotor case stiffener rings, not anticipated by engineering designers. In another case, a particularly difficult resonance contraint could not be satisfied using hand iterations for a compressor blade, when the STAEBL program was applied to the problem, a feasible solution was obtained in just two iterations.
Schlaich, Clara; Gau, Bettina; Cohen, Nicole J; Kojima, Kazunobu; Marano, Nina; Menucci, Daniel
2012-01-01
Shipping companies were surveyed to evaluate the effect of public health measures during the influenza A (H1N1) pandemic of 2009 on ship and port operations. Of 31 companies that operated 960 cruise, cargo, and other ships, 32% experienced health-screening measures by port health authorities. Approximately a quarter of ports (26%) performed screening at embarkation and 77% of shipping companies changed procedures during the early stage of the pandemic. Four companies reported outbreaks of pandemic influenza A (H1N1) 2009 on ships, which were ultimately stopped through infection control practices. Public health measures did not interfere substantially with port and ship operations with the exception of some port authorities that delayed embarking and disembarking procedures in a few ships. However, in the shipping companies' experience, measures were inconsistent between port health authorities. Access to antiviral drugs and pandemic vaccine was not provided in all ports. Current guidelines on medical care, hygiene, and emergency procedures on ships need to address pandemic influenza preparedness in future revisions.
Carlsen, Brian T; Prigge, Pat; Peterson, Jennifer
2014-01-01
For several decades, prosthetic use was the only option to restore function after upper extremity amputation. Recent years have seen advances in the field of prosthetics. Such advances include prosthetic design and function, activity-specific devices, improved aesthetics, and adjunctive surgical procedures to improve both form and function. Targeted reinnervation is one exciting advance that allows for more facile and more intuitive function with prosthetics following proximal amputation. Another remarkable advance that holds great promise in nearly all fields of medicine is the transplantation of composite tissue, such as hand and face transplantation. Hand transplantation holds promise as the ultimate restorative procedure that can provide form, function, and sensation. However, this procedure still comes with a substantial cost in terms of the rehabilitation and toxic immunosuppression and should be limited to carefully selected patients who have failed prosthetic reconstruction. Hand transplantation and prosthetic reconstruction should not be viewed as competing options. Rather, they are two treatment options with different risk/benefit profiles and different indications and, hence vastly different implications. Copyright © 2014 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Rao, Allison J.; Erickson, Brandon J.; Cvetanovich, Gregory L.; Yanke, Adam B.; Bach, Bernard R.; Cole, Brian J.
2015-01-01
Meniscal tears are the most common knee injury, and partial meniscectomies are the most common orthopaedic surgical procedure. The injured meniscus has an impaired ability to distribute load and resist tibial translation. Partial or complete loss of the meniscus promotes early development of chondromalacia and osteoarthritis. The primary goal of treatment for meniscus-deficient knees is to provide symptomatic relief, ideally to delay advanced joint space narrowing, and ultimately, joint replacement. Surgical treatments, including meniscal allograft transplantation (MAT), high tibial osteotomy (HTO), and distal femoral osteotomy (DFO), are options that attempt to decrease the loads on the articular cartilage of the meniscus-deficient compartment by replacing meniscal tissue or altering joint alignment. Clinical and biomechanical studies have reported promising outcomes for MAT, HTO, and DFO in the postmeniscectomized knee. These procedures can be performed alone or in conjunction with ligament reconstruction or chondral procedures (reparative, restorative, or reconstructive) to optimize stability and longevity of the knee. Complications can include fracture, nonunion, patella baja, compartment syndrome, infection, and deep venous thrombosis. MAT, HTO, and DFO are effective options for young patients suffering from pain and functional limitations secondary to meniscal deficiency. PMID:26779547
A comparison of methods for teaching receptive language to toddlers with autism.
Vedora, Joseph; Grandelski, Katrina
2015-01-01
The use of a simple-conditional discrimination training procedure, in which stimuli are initially taught in isolation with no other comparison stimuli, is common in early intensive behavioral intervention programs. Researchers have suggested that this procedure may encourage the development of faulty stimulus control during training. The current study replicated previous work that compared the simple-conditional and the conditional-only methods to teach receptive labeling of pictures to young children with autism spectrum disorder. Both methods were effective, but the conditional-only method required fewer sessions to mastery. © Society for the Experimental Analysis of Behavior.
Turrentine, Florence E; Wang, Hongkun; Young, Jeffrey S; Calland, James Forrest
2010-08-01
Ever-increasing numbers of in-house acute care surgeons and competition for operating room time during normal daytime business hours have led to an increased frequency of nonemergent general and vascular surgery procedures occurring at night when there are fewer residents, consultants, nurses, and support staff available for assistance. This investigation tests the hypothesis that patients undergoing such procedures after hours are at increased risk for postoperative morbidity and mortality. Clinical data for 10,426 operative procedures performed over a 5-year period at a single academic tertiary care hospital were obtained from the American College of Surgeons National Surgical Quality Improvement Program Database. The prevalence of preoperative comorbid conditions, postoperative length of stay, morbidity, and mortality was compared between two cohorts of patients: one who underwent nonemergent operative procedures at night and other who underwent similar procedures during the day. Subsequent statistical comparisons utilized chi tests for comparisons of categorical variables and F-tests for continuous variables. Patients undergoing procedures at night had a greater prevalence of serious preoperative comorbid conditions. Procedure complexity as measured by relative value unit did not differ between groups, but length of stay was longer after night procedures (7.8 days vs. 4.3 days, p < 0.0001). Patients undergoing nonemergent general and vascular surgery procedures at night in an academic medical center do not seem to be at increased risk for postoperative morbidity or mortality. Performing nonemergent procedures at night seems to be a safe solution for daytime overcrowding of operating rooms.
Effect of injection augmentation on need for framework surgery in unilateral vocal fold paralysis.
Francis, David O; Williamson, Kelly; Hovis, Kristen; Gelbard, Alexander; Merati, Albert L; Penson, David F; Netterville, James L; Garrett, C Gaelyn
2016-01-01
To determine whether injection augmentation reduces the likelihood of ultimately needing definitive framework surgery in unilateral vocal fold paralysis (UVFP) patients. Retrospective cohort study. All patients diagnosed with UVFP (2008-2012) at the academic center were identified. The time from symptom onset to presentation to either community otolaryngologist and/or academic center, as well as any directed treatment(s), were recorded. Stepwise, multivariate logistic regression analysis was used to determine whether injection augmentation independently affected odds of needing definitive, framework surgery among patients who were seen within 9 months of symptom onset and had not undergone any prior rehabilitative procedures. Cohort consisted of 633 patients (55% female, 80% Caucasian, median age 60 years) with UVFP. The majority of etiologies were either surgery (48%) or idiopathic (37%). Duration to presentation at community otolaryngologist was shorter than to the academic center (median 2 vs. 6 months). Overall, less than half of UVFP patients had any operation (46%). Multivariate logistic regression found that earlier injection augmentation did not affect odds of ultimately undergoing framework surgery (odds ratio 1.13; confidence interval, 0.92-1.40; P = 0.23). Nearly half of UVFP patients do not require any rehabilitative procedure. When indicated, early injection augmentation is effective at temporarily alleviating associated symptoms but does not reduce likelihood of needing a definitive framework operation in patients with UVFP. Understanding practice patterns and fostering early detection and treatment may improve quality of life in this patient population. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
NASA Astrophysics Data System (ADS)
Favero, Valentina; Ferrari, Alessio; Laloui, Lyesse
2018-05-01
This paper investigates the anisotropic hydro-mechanical behaviour of Opalinus Clay shale, the host material currently being considered for the construction of a nuclear waste repository in Switzerland. Consolidated and drained triaxial tests on Opalinus Clay from the Mont Terri URL have been conducted in order to derive information on its strength and stiffness properties. Opalinus Clay specimens were tested both parallel to bedding (P-specimens) and perpendicular to bedding (S-specimens). The considered effective confining stress range (from 2 to 12 MPa) has been selected in order to reproduce possible in situ stress conditions for the repository. In this work, particular attention has been paid to the experimental procedure in order to ensure consolidated conditions and avoid generation of unwanted excess pore water pressure during drained shearing. The Skempton B parameter has been determined for all the tested specimens in order to ensure saturation. Both single-stage and multistage triaxial testing procedures were adopted in the experimental campaign. The results of the triaxial tests highlight an anisotropic elastic response of Opalinus Clay: S-specimens present a more compliant behaviour than P-specimens. The values of the Young modulus are found to increase with the increase in mean effective stress. The analysis of the peak and ultimate shear strength results reveals that the material behaves in a similar manner regardless of the considered direction of loading (P and S directions) with respect to the bedding orientation. Peak and ultimate failure envelopes for Opalinus Clay were derived for the investigated stress range.
Self-Management Procedures: A Comparison across the Autism Spectrum
ERIC Educational Resources Information Center
Southall, Candice M.; Gast, David L.
2011-01-01
Individuals with autism spectrum disorders (ASD) have difficulty generalizing learned behavior to varied environments with independence. This review of 24 empirical studies compares self-management as a systematic procedure for modifying one's own behavior, to increase target behaviors in students with either autistic disorder (AD) or…
DOT National Transportation Integrated Search
2004-12-01
In an effort to compare performance and cost effectiveness of the Saw and Seal procedure and : Performance Grade (PG) binders, the Maine Department of Transportation (MDOT) constructed an : experimental project in Weston, Maine during the fall ...
DOT National Transportation Integrated Search
2004-07-01
In an effort to compare performance and cost effectiveness of the Saw and Seal procedure and : Performance Grade (PG) binders, the Maine Department of Transportation (MDOT) constructed an : experimental project in Weston, Maine during the fall ...
Job-Seeking Interview Skills Training: A Comparison of Four Instructional Techniques.
ERIC Educational Resources Information Center
Speas, Carol Mendenhall
1979-01-01
Compared model exposure (MOD), role playing (RP), model exposure plus role playing (MRP), and model exposure role playing with videotape feedback (VIDEO). MRP and VIDEO treatments were greater than control procedures. RP treatment was more effective than control procedures on two criteria. (Author/BEF)
Comparison of Traditional and Trial-Based Methodologies for Conducting Functional Analyses
ERIC Educational Resources Information Center
LaRue, Robert H.; Lenard, Karen; Weiss, Mary Jane; Bamond, Meredith; Palmieri, Mark; Kelley, Michael E.
2010-01-01
Functional analysis represents a sophisticated and empirically supported functional assessment procedure. While these procedures have garnered considerable empirical support, they are often underused in clinical practice. Safety risks resulting from the evocation of maladaptive behavior and the length of time required to conduct functional…
Peroral Endoscopic Myotomy Versus Heller Myotomy for Achalasia: Pros and Cons.
Tefas, Cristian; Ababneh, Rami; Tanţău, Marcel
2018-01-01
Achalasia is an esophageal motor disorder that has multiple endoscopic and surgical methods of treatment. However, there is no consensus on optimal therapy in patients suffering from this disorder. This review discusses two therapies with similar but technically different concepts, peroral endoscopic myotomy and Heller surgical myotomy. After a brief introduction to the basic problems of achalasia, technical considerations, intra and postprocedural complications are presented and the advantages and disadvantages of the two procedures are discussed, based on the relevant articles in the literature. Heller surgical myotomy and peroral endoscopic myotomy appear to be similar in performance with similar results in terms of gastroesophageal reflux rates. However, with experience being gained in the field of endoscopic myotomy, this procedure seems more advantageous, with similar success rates to those of the established surgical technique, but offering shorter operating times, shorter hospitalizations and, ultimately, lower costs. Celsius.
Application for certification for 1979 model year for light-duty vehicles - Audi
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Every year, each manufacturer of passenger cars, light-duty trucks, motorcycles or heavy-duty engines submits to EPA an application for certification. The application consists of two parts. In the part I, the manufacturer gives a detailed technical description of the vehicles or engines he intends to market during the upcoming model year. These engineering data include explanations and/or drawings which describe engine/vehicle parameters such as basic engine design, fuel systems, ignition systems and exhaust and evaporative emission control systems. The part I also provides information on emission test procedures, service accumulation procedures, fuels to be used, and proposed maintenance requirements tomore » be followed during testing. The part II application submitted after emission testing is completed, contains the results of emission testing, a statement of compliance to the regulations, and maintenance instructions to be followed by the ultimate owners of the vehicles.« less
Landwehr, Claudia; Klinnert, Dorothea
2015-04-01
Most developed democracies have faced the challenge of priority setting in health care by setting up specialized agencies to take decisions on which medical services to include in public health baskets. Under the influence of Daniels and Sabin's seminal work on the topic, agencies increasingly aim to fulfil criteria of procedural justice, such as accountability and transparency. We assume, however, that the institutional design of agencies also and necessarily reflects substantial value judgments on the respective weight of distributive principles such as efficiency, need and equality. The public acceptance of prioritization decisions, and eventually of the health care system at large, will ultimately depend not only on considerations of procedural fairness, but also on the congruence between a society's values and its institutions. We study social values, institutions and decisions in three countries (France, Germany and the United Kingdom) in order to assess such congruence and formulate expectations on its effects.
Application for certification for 1979 model year for light-duty vehicles - Peugeot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Every year, each manufacturer of passenger cars, light-duty trucks, motorcycles or heavy-duty engines submits to EPA an application for certification. The application consists of two parts. In the part I, the manufacturer gives a detailed technical description of the vehicles or engines he intends to market during the upcoming model year. These engineering data include explanations and/or drawings which describe engine/vehicle parameters such as basic engine design, fuel systems, ignition systems and exhaust and evaporative emission control systems. The part I also provides information on emission test procedures, service accumulation procedures, fuels to be used, and proposed maintenance requirements tomore » be followed during testing. The part II application, submitted after emission testing is completed, contains the results of emission testing, a statement of compliance to the regulations, and maintenance instructions to be followed by the ultimate owners of the vehicles.« less
Functional Disorders: Slow-Transit Constipation
Tillou, John; Poylin, Vitaliy
2017-01-01
Constipation is a very common complaint, with slow-transit constipation (STC) accounting for a significant proportion of cases. Old age, female gender, psychiatric illness, and history of sexual abuse are all associated with STC. The exact cause of STC remains elusive; however, multiple immune and cellular changes have been demonstrated. Diagnosis requires evidence of slowed colonic transit which may be achieved via numerous modalities. While a variety of medical therapies exist, these are often met with limited success and a minority of patients ultimately require operative intervention. When evaluating a patient with STC, it is important to determine the presence of concomitant obstructed defecation or other forms of enteric dysmotility, as this may affect treatment decisions. Although a variety of surgical procedures have been reported, subtotal colectomy with ileorectal anastomosis is the most commonly performed and well-studied procedure, with the best track record of success. PMID:28144215
Menditto, Anthony A; Linhorst, Donald M; Coleman, James C; Beck, Niels C
2006-04-01
Development of policies and procedures to contend with the risks presented by elopement, aggression, and suicidal behaviors are long-standing challenges for mental health administrators. Guidance in making such judgments can be obtained through the use of a multivariate statistical technique known as logistic regression. This procedure can be used to develop a predictive equation that is mathematically formulated to use the best combination of predictors, rather than considering just one factor at a time. This paper presents an overview of logistic regression and its utility in mental health administrative decision making. A case example of its application is presented using data on elopements from Missouri's long-term state psychiatric hospitals. Ultimately, the use of statistical prediction analyses tempered with differential qualitative weighting of classification errors can augment decision-making processes in a manner that provides guidance and flexibility while wrestling with the complex problem of risk assessment and decision making.
A 100-Year Review: Sensory analysis of milk.
Schiano, A N; Harwood, W S; Drake, M A
2017-12-01
Evaluation of the sensory characteristics of food products has been, and will continue to be, the ultimate method for evaluating product quality. Sensory quality is a parameter that can be evaluated only by humans and consists of a series of tests or tools that can be applied objectively or subjectively within the constructs of carefully selected testing procedures and parameters. Depending on the chosen test, evaluators are able to probe areas of interest that are intrinsic product attributes (e.g., flavor profiles and off-flavors) as well as extrinsic measures (e.g., market penetration and consumer perception). This review outlines the literature pertaining to relevant testing procedures and studies of the history of sensory analysis of fluid milk. In addition, evaluation methods outside of traditional sensory techniques and future outlooks on the subject of sensory analysis of fluid milk are explored and presented. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pseudomonas aeruginosa Infective Endocarditis Following Aortic Valve Implantation: A Note of Caution
Dapás, Juan Ignacio; Rivero, Cynthia; Burgos, Pablo; Vila, Andrea
2016-01-01
Transcatheter aortic valve implantation (TAVI) is an alternative treatment for severe aortic valve stenosis (AS) in patients with prohibitive risk for surgical aortic valve replacement (SAVR). Prosthetic valve endocarditis (PVE) is a rare complication of this relatively novel procedure and current guidelines do not include specific recommendations for its treatment. We report a case of PVE due to Pseudomonas aeruginosa after TAVI that required SAVR, with successful outcome. PVE usually occurs during the first year after TAVI and entails a high mortality risk because patients eligible for this min-imally invasive procedure are fragile (i.e. advanced age and/or severe comorbidities). Additionally, clinical presentation may be atypical or subtle and transesophageal echocardiogram (TEE) may not be conclusive, which delays diagnosis and treatment worsening the prognosis. This case highlights that open SAVR might be ultimately indicated as part of treatment for TAVI-PVE despite a high-risk surgery score. PMID:27014375
Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.
Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. Themore » third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients.« less
Carroll, Diane L
2014-01-01
In a growing number of requests, family members are asking for proximity to their family member during resuscitation and invasive procedures. The objective of this study was to measure the impact of intensive care unit environments on nurse perception of family presence during resuscitation and invasive procedures. The study used a descriptive survey design with nurses from 9 intensive care units using the Family Presence Self-confidence Scale for resuscitation/invasive procedures that measures nurses' perception of self-confidence and Family Presence Risk-Benefit Scale for resuscitation and invasive procedures that measures nurses' perception of risks/benefits related to managing resuscitation and invasive procedures with family present. There were 207 nurses who responded: 14 male and 184 female nurses (9 missing data), with mean age of 41 ± 11 years, with a mean of 15 years in critical care practice. The environments were defined as surgical (n = 68), medical (n = 43), pediatric/neonatal (n = 34), and mixed adult medical/surgical (n = 36) intensive care units. There were significant differences in self-confidence, with medical and pediatric intensive care unit nurses rating more self-confidence for family presence during resuscitation (F = 7.73, P < .000) and invasive procedures (F = 6.41, P < .000). There were significant differences in risks/benefits with medical and pediatric intensive care unit nurses rating lower risk and higher benefit for resuscitation (F = 7.73, P < .000). Perceptions of family presence were significantly higher for pediatric and medical intensive care unit nurses. Further education and support may be needed in the surgical and mixed intensive care units. Evidence-based practice guidelines that are family centered can define the procedures and resources for family presence, to ultimately promote professional practice.
Özden Omaygenç, Derya; Ünal, Nermin; Edipoğlu, Saadet İpek; Barca Şeker, Tuğçe; Özgül, Mehmet Akif; Turan, Demet; Özdemir, Cengiz; Karaca, İbrahim Oğuz; Çetinkaya, Erdoğan
2018-04-16
Regarding the fact that rigid bronchoscopy is generally performed under general anaesthesia and this patient subgroup is remarkably morbid, encountering procedure and/or anaesthesia related complications are highly likely. Here, we aimed to assess factors influencing recovery and detect possible determinants of adverse event occurrence during these operations performed in a tertiary referral centre. Eighty-one consecutive ASA I-IV patients were recruited for this investigation. In the operating theatre after induction of anaesthesia and advancement of the device, maintenance was provided with total intravenous anaesthesia. Neuromuscular blockage was invariably administered, and patients were ventilated manually. In addition to preoperative demographic and procedural characteristics, perioperative hemodynamic variables, recovery times and observed adverse events were noted. Basic demographic properties, ASA and Mallampati scores, and procedure specific variables as lesion localization, lesion and procedure type were comparable among groups assembled with reference to event occurrence. Patients who had experienced adverse event had higher heart rates. Recovery times were comparable between Event (-) and Event (+) groups. Relationship of recovery process were individually tested with all variables and only lesion type was detected to have an effect on respiration and extubation times. Among all parameters only procedural time seemed to be associated with adverse event occurrence (mins, 22.9 ± 11.9 vs 41.6 ± 28.8, P < .001). Recovery times related with return of spontaneous respiration were significantly lower in procedures performed for treatment of tumoral diseases in this study and procedure length was determined to be the ultimate factor which had an impact on adverse event occurrence. © 2018 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Handley, John C.; Babcock, Jason S.; Pelz, Jeff B.
2003-12-01
Image evaluation tasks are often conducted using paired comparisons or ranking. To elicit interval scales, both methods rely on Thurstone's Law of Comparative Judgment in which objects closer in psychological space are more often confused in preference comparisons by a putative discriminal random process. It is often debated whether paired comparisons and ranking yield the same interval scales. An experiment was conducted to assess scale production using paired comparisons and ranking. For this experiment a Pioneer Plasma Display and Apple Cinema Display were used for stimulus presentation. Observers performed rank order and paired comparisons tasks on both displays. For each of five scenes, six images were created by manipulating attributes such as lightness, chroma, and hue using six different settings. The intention was to simulate the variability from a set of digital cameras or scanners. Nineteen subjects, (5 females, 14 males) ranging from 19-51 years of age participated in this experiment. Using a paired comparison model and a ranking model, scales were estimated for each display and image combination yielding ten scale pairs, ostensibly measuring the same psychological scale. The Bradley-Terry model was used for the paired comparisons data and the Bradley-Terry-Mallows model was used for the ranking data. Each model was fit using maximum likelihood estimation and assessed using likelihood ratio tests. Approximate 95% confidence intervals were also constructed using likelihood ratios. Model fits for paired comparisons were satisfactory for all scales except those from two image/display pairs; the ranking model fit uniformly well on all data sets. Arguing from overlapping confidence intervals, we conclude that paired comparisons and ranking produce no conflicting decisions regarding ultimate ordering of treatment preferences, but paired comparisons yield greater precision at the expense of lack-of-fit.
Kokanalı, Mahmut Kuntay; Cavkaytar, Sabri; Kokanalı, Demet; Aksakal, Orhan; Doganay, Melike
2016-11-01
There is little data comparing the surgical outcomes of tension-free vaginal tape (TVT) and transobturator tape (TOT) procedures in obese women. Therefore, we aimed to compare the surgical outcomes of TOT and TVT procedures among obese women with a diagnosis of stress urinary incontinence (SUI). One hundred and eighty-nine women who underwent TVT or TOT procedures due to pure SUI were included. Women in whom the body mass index (BMI) was ≥30 kg/m 2 were considered as obese, while <30 kg/m 2 were non-obese. And women with BMI ≥35 kg/m 2 was defined as morbidly obese. At sixth month postoperative follow-up, neither the comparison of TVT and TOT results in obese women nor the comparison of TVT or TOT results between obese and non-obese women showed any significant differences in terms of objective and subjective cure rates, quality of life improvements, or intra/postoperative complications. TVT and TOT procedures also have similar effectiveness among morbidly obese women. We have concluded that TVT and TOT operations seem to be equally effective and safe surgical treatment procedures for female SUI regardless of BMI.
Cook, Troy A.
2013-01-01
Estimated ultimate recoveries (EURs) are a key component in determining productivity of wells in continuous-type oil and gas reservoirs. EURs form the foundation of a well-performance-based assessment methodology initially developed by the U.S. Geological Survey (USGS; Schmoker, 1999). This methodology was formally reviewed by the American Association of Petroleum Geologists Committee on Resource Evaluation (Curtis and others, 2001). The EUR estimation methodology described in this paper was used in the 2013 USGS assessment of continuous oil resources in the Bakken and Three Forks Formations and incorporates uncertainties that would not normally be included in a basic decline-curve calculation. These uncertainties relate to (1) the mean time before failure of the entire well-production system (excluding economics), (2) the uncertainty of when (and if) a stable hyperbolic-decline profile is revealed in the production data, (3) the particular formation involved, (4) relations between initial production rates and a stable hyperbolic-decline profile, and (5) the final behavior of the decline extrapolation as production becomes more dependent on matrix storage.
Plume interference with space shuttle range safety signals
NASA Technical Reports Server (NTRS)
Boynton, F. P.; Rajaseknar, P. S.
1979-01-01
The computational procedure for signal propagation in the presence of an exhaust plume is presented. Comparisons with well-known analytic diffraction solutions indicate that accuracy suffers when mesh spacing is inadequate to resolve the first unobstructed Fresnel zone at the plume edge. Revisions to the procedure to improve its accuracy without requiring very large arrays are discussed. Comparisons to field measurements during a shuttle solid rocket motor (SRM) test firing suggest that the plume is sharper edged than one would expect on the basis of time averaged electron density calculations. The effects, both of revisions to the computational procedure and of allowing for a sharper plume edge, are to raise the signal level near tail aspect. The attenuation levels then predicted are still high enough to be of concern near SRM burnout for northerly launches of the space shuttle.
Dahling, D R; Wright, B A
1988-12-01
An improved concentration method using sample volumes as large as 1500 ml has been developed to monitor for viruses in wastewaters. Non-precipitating dry beef extract powder is added to wastewater samples to give a 3% concentration and mixed until dissolved. This is followed by the addition of Celite as a virus adsorbent. By manipulating pH, viruses are eluted from the Celite in small volumes of phosphate buffer. This procedure was further tested without the aid of the Celite additives using a precipitating beef extract powder and substituting FeCl3 as an alternate reagent for the Celite. Comparison testing was also made with the currently recommended cartridge and disc filter procedures. In all cases, the non-precipitating beef extract-Celite method gave higher recovery rates in highly polluted waters.
Sandhu, Gurkirat; Khinda, Paramjit Kaur; Gill, Amarjit Singh; Singh Khinda, Vineet Inder; Baghi, Kamal; Chahal, Gurparkash Singh
2017-01-01
Context: Periodontal surgical procedures produce varying degree of stress in all patients. Nitrous oxide-oxygen inhalation sedation is very effective for adult patients with mild-to-moderate anxiety due to dental procedures and needle phobia. Aim: The present study was designed to perform periodontal surgical procedures under nitrous oxide-oxygen inhalation sedation and assess whether this technique actually reduces stress physiologically, in comparison to local anesthesia alone (LA) during lengthy periodontal surgical procedures. Settings and Design: This was a randomized, split-mouth, cross-over study. Materials and Methods: A total of 16 patients were selected for this randomized, split-mouth, cross-over study. One surgical session (SS) was performed under local anesthesia aided by nitrous oxide-oxygen inhalation sedation, and the other SS was performed on the contralateral quadrant under LA. For each session, blood samples to measure and evaluate serum cortisol levels were obtained, and vital parameters including blood pressure, heart rate, respiratory rate, and arterial blood oxygen saturation were monitored before, during, and after periodontal surgical procedures. Statistical Analysis Used: Paired t-test and repeated measure ANOVA. Results: The findings of the present study revealed a statistically significant decrease in serum cortisol levels, blood pressure and pulse rate and a statistically significant increase in respiratory rate and arterial blood oxygen saturation during periodontal surgical procedures under nitrous oxide inhalation sedation. Conclusion: Nitrous oxide-oxygen inhalation sedation for periodontal surgical procedures is capable of reducing stress physiologically, in comparison to LA during lengthy periodontal surgical procedures. PMID:29386796
Ishii, Yuri; Ishihara, Junko; Takachi, Ribeka; Shinozawa, Yurie; Imaeda, Nahomi; Goto, Chiho; Wakai, Kenji; Takahashi, Toshiaki; Iso, Hiroyasu; Nakamura, Kazutoshi; Tanaka, Junta; Shimazu, Taichi; Yamaji, Taiki; Sasazuki, Shizuka; Sawada, Norie; Iwasaki, Motoki; Mikami, Haruo; Kuriki, Kiyonori; Naito, Mariko; Okamoto, Naoko; Kondo, Fumi; Hosono, Satoyo; Miyagawa, Naoko; Ozaki, Etsuko; Katsuura-Kamano, Sakurako; Ohnaka, Keizo; Nanri, Hinako; Tsunematsu-Nakahata, Noriko; Kayama, Takamasa; Kurihara, Ayako; Kojima, Shiomi; Tanaka, Hideo; Tsugane, Shoichiro
2017-07-01
Although open-ended dietary assessment methods, such as weighed food records (WFRs), are generally considered to be comparable, differences between procedures may influence outcome when WFRs are conducted independently. In this paper, we assess the procedures of WFRs in two studies to describe their dietary assessment procedures and compare the subsequent outcomes. WFRs of 12 days (3 days for four seasons) were conducted as reference methods for intake data, in accordance with the study protocol, among a subsample of participants of two large cohort studies. We compared the WFR procedures descriptively. We also compared some dietary intake variables, such as the frequency of foods and dishes and contributing foods, to determine whether there were differences in the portion size distribution and intra- and inter-individual variation in nutrient intakes caused by the difference in procedures. General procedures of the dietary records were conducted in accordance with the National Health and Nutrition Survey and were the same for both studies. Differences were seen in 1) selection of multiple days (non-consecutive days versus consecutive days); and 2) survey sheet recording method (individual versus family participation). However, the foods contributing to intake of energy and selected nutrients, the portion size distribution, and intra- and inter-individual variation in nutrient intakes were similar between the two studies. Our comparison of WFR procedures in two independent studies revealed several differences. Notwithstanding these procedural differences, however, the subsequent outcomes were similar. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.
Estimating Regional Mass Balance of Himalayan Glaciers Using Hexagon Imagery: An Automated Approach
NASA Astrophysics Data System (ADS)
Maurer, J. M.; Rupper, S.
2013-12-01
Currently there is much uncertainty regarding the present and future state of Himalayan glaciers, which supply meltwater for river systems vital to more than 1.4 billion people living throughout Asia. Previous assessments of regional glacier mass balance in the Himalayas using various remote sensing and field-based methods give inconsistent results, and most assessments are over relatively short (e.g., single decade) timescales. This study aims to quantify multi-decadal changes in volume and extent of Himalayan glaciers through efficient use of the large database of declassified 1970-80s era Hexagon stereo imagery. Automation of the DEM extraction process provides an effective workflow for many images to be processed and glacier elevation changes quantified with minimal user input. The tedious procedure of manual ground control point selection necessary for block-bundle adjustment (as ephemeral data is not available for the declassified images) is automated using the Maximally Stable Extremal Regions algorithm, which matches image elements between raw Hexagon images and georeferenced Landsat 15 meter panchromatic images. Additional automated Hexagon DEM processing, co-registration, and bias correction allow for direct comparison with modern ASTER and SRTM elevation data, thus quantifying glacier elevation and area changes over several decades across largely inaccessible mountainous regions. As consistent methodology is used for all glaciers, results will likely reveal significant spatial and temporal patterns in regional ice mass balance. Ultimately, these findings could have important implications for future water resource management in light of environmental change.
Camargo, Anderson Carlos; Woodward, Joshua John; Call, Douglas Ruben; Nero, Luís Augusto
2017-11-01
Listeria monocytogenes is a foodborne pathogen that contaminates food-processing environments and persists within biofilms on equipment, utensils, floors, and drains, ultimately reaching final products by cross-contamination. This pathogen grows even under high salt conditions or refrigeration temperatures, remaining viable in various food products until the end of their shelf life. While the estimated incidence of listeriosis is lower than other enteric illnesses, infections caused by L. monocytogenes are more likely to lead to hospitalizations and fatalities. Despite the description of L. monocytogenes occurrence in Brazilian food-processing facilities and foods, there is a lack of consistent data regarding listeriosis cases and outbreaks directly associated with food consumption. Listeriosis requires rapid treatment with antibiotics and most drugs suitable for Gram-positive bacteria are effective against L. monocytogenes. Only a minority of clinical antibiotic-resistant L. monocytogenes strains have been described so far; whereas many strains recovered from food-processing facilities and foods exhibited resistance to antimicrobials not suitable against listeriosis. L. monocytogenes control in food industries is a challenge, demanding proper cleaning and application of sanitization procedures to eliminate this foodborne pathogen from the food-processing environment and ensure food safety. This review focuses on presenting the L. monocytogenes distribution in food-processing environment, food contamination, and control in the food industry, as well as the consequences of listeriosis to human health, providing a comparison of the current Brazilian situation with the international scenario.
Mattai, Anand A.; Weisinger, Brian; Greenstein, Deanna; Stidd, Reva; Clasen, Liv; Miller, Rachel; Tossell, Julia W.; Rapoport, Judith L.; Gogtay, Nitin
2012-01-01
Objective Cortical gray matter (GM) abnormalities in patients with childhood-onset schizophrenia (COS) progress during adolescence ultimately localizing to prefrontal and temporal cortices by early adult age. A previous study of 52 nonpsychotic siblings of COS probands had significant prefrontal and temporal GM deficits that appeared to “normalize” by age 17 years. Here we present a replication with nonoverlapping groups of healthy full siblings and healthy controls. Method Using an automated measure and prospectively acquired anatomical brain magnetic resonance images, we mapped cortical GM thickness in nonpsychotic full siblings (n = 43, 68 scans; ages 5 through 26 years) of patients with COS, contrasting them with age-, gender-, and scan interval–matched healthy controls (n = 86, 136 scans). The false-discovery rate procedure was used to control for type I errors due to multiple comparisons. Results As in our previous study, young nonpsychotic siblings (<17 years) showed significant GM deficits in bilateral prefrontal and left temporal cortices and, in addition, smaller deficits in the parietal and right inferior temporal cortices. These deficits in nonpsychotic siblings normalized with age with minimal abnormalities remaining by age 17. Conclusions Our results support previous findings showing nonpsychotic siblings of COS probands to have early GM deficits that ameliorate with time. At early ages, prefrontal and/or temporal loss may serve as a familial/trait marker for COS. Late adolescence appears to be a critical period for greatest localization of deficits in probands or normalization in nonpsychotic siblings. PMID:21703497
Waste in the U.S. Health care system: a conceptual framework.
Bentley, Tanya G K; Effros, Rachel M; Palar, Kartika; Keeler, Emmett B
2008-12-01
Health care costs in the United States are much higher than those in industrial countries with similar or better health system performance. Wasteful spending has many undesirable consequences that could be alleviated through waste reduction. This article proposes a conceptual framework to guide researchers and policymakers in evaluating waste, implementing waste-reduction strategies, and reducing the burden of unnecessary health care spending. This article divides health care waste into administrative, operational, and clinical waste and provides an overview of each. It explains how researchers have used both high-level and sector- or procedure-specific comparisons to quantify such waste, and it discusses examples and challenges in both waste measurement and waste reduction. Waste is caused by factors such as health insurance and medical uncertainties that encourage the production of inefficient and low-value services. Various efforts to reduce such waste have encountered challenges, such as the high costs of initial investment, unintended administrative complexities, and trade-offs among patients', payers', and providers' interests. While categorizing waste may help identify and measure general types and sources of waste, successful reduction strategies must integrate the administrative, operational, and clinical components of care, and proceed by identifying goals, changing systemic incentives, and making specific process improvements. Classifying, identifying, and measuring waste elucidate its causes, clarify systemic goals, and specify potential health care reforms that-by improving the market for health insurance and health care-will generate incentives for better efficiency and thus ultimately decrease waste in the U.S. health care system.
Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai
2013-11-01
A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Development of a High Resolution 3D Infant Stomach Model for Surgical Planning
NASA Astrophysics Data System (ADS)
Chaudry, Qaiser; Raza, S. Hussain; Lee, Jeonggyu; Xu, Yan; Wulkan, Mark; Wang, May D.
Medical surgical procedures have not changed much during the past century due to the lack of accurate low-cost workbench for testing any new improvement. The increasingly cheaper and powerful computer technologies have made computer-based surgery planning and training feasible. In our work, we have developed an accurate 3D stomach model, which aims to improve the surgical procedure that treats the infant pediatric and neonatal gastro-esophageal reflux disease (GERD). We generate the 3-D infant stomach model based on in vivo computer tomography (CT) scans of an infant. CT is a widely used clinical imaging modality that is cheap, but with low spatial resolution. To improve the model accuracy, we use the high resolution Visible Human Project (VHP) in model building. Next, we add soft muscle material properties to make the 3D model deformable. Then we use virtual reality techniques such as haptic devices to make the 3D stomach model deform upon touching force. This accurate 3D stomach model provides a workbench for testing new GERD treatment surgical procedures. It has the potential to reduce or eliminate the extensive cost associated with animal testing when improving any surgical procedure, and ultimately, to reduce the risk associated with infant GERD surgery.
Assessment of Dimensionality in Social Science Subtest
ERIC Educational Resources Information Center
Ozbek Bastug, Ozlem Yesim
2012-01-01
Most of the literature on dimensionality focused on either comparison of parametric and nonparametric dimensionality detection procedures or showing the effectiveness of one type of procedure. There is no known study to shown how to do combined parametric and nonparametric dimensionality analysis on real data. The current study is aimed to fill…
A Comparison of Approaches for Setting Proficiency Standards.
ERIC Educational Resources Information Center
Koffler, Stephen L.
This research compared the cut-off scores estimated from an empirical procedure (Contrasting group method) to those determined from a more theoretical process (Nedelsky method). A methodological and statistical framework was also provided for analysis of the data to obtain the most appropriate standard using the empirical procedure. Data were…
Equipment-Device Task Commonality Analysis and Transfer of Training.
ERIC Educational Resources Information Center
Caro, Paul W.
Procedures were developed to enable training personnel systematically and objectively to determine the potential utility of training devices for teaching how to perform missions in operational rotary wing aircraft. These procedures allow comparison of task stimulus and response elements with corresponding elements in synthetic training equipment.…
DOT National Transportation Integrated Search
2008-12-01
In an effort to compare performance and cost effectiveness of the Saw and Seal procedure and : Performance Grade (PG) binders, the Maine Department of Transportation (MaineDOT) constructed an : experimental project in Weston, Maine during the f...
A Simulation Comparison of Parametric and Nonparametric Dimensionality Detection Procedures
ERIC Educational Resources Information Center
Mroch, Andrew A.; Bolt, Daniel M.
2006-01-01
Recently, nonparametric methods have been proposed that provide a dimensionally based description of test structure for tests with dichotomous items. Because such methods are based on different notions of dimensionality than are assumed when using a psychometric model, it remains unclear whether these procedures might lead to a different…
A COMPARISON OF MAPPED ESTIMATES OF LONG-TERM RUNOFF IN THE NORTHEAST UNITED STATES
We evaluated the relative accuracy of four methods of producing maps of long-term runoff for part of the northeast United States: MAN, a manual procedure that incorporates expert opinion in contour placement; RPRIS, an automated procedure based on water balance considerations, Pn...
Detonation energies of explosives by optimized JCZ3 procedures
NASA Astrophysics Data System (ADS)
Stiel, Leonard I.; Baker, Ernest L.
1998-07-01
Procedures for the detonation properties of explosives have been extended for the calculation of detonation energies at adiabatic expansion conditions. The use of the JCZ3 equation of state with optimized Exp-6 potential parameters leads to lower errors in comparison to JWL detonation energies than for other methods tested.
A Comparison of Three Covert Assertion Training Procedures.
ERIC Educational Resources Information Center
Twentyman, Craig T.; And Others
1980-01-01
Assessed the effectiveness of covert modification procedures in an assertion training program. All treatment groups were superior to the control in behavioral ratings of assertiveness during the posttest in those situations that had been employed previously in treatment; two were superior in those that had not been used, providing evidence of…
Tewari, Satyendra; Sharma, Naveen; Kapoor, Aditya; Syal, Sanjeev Kumar; Kumar, Sudeep; Garg, Naveen; Goel, Pravin K
2013-01-01
With the increasing prevalence of coronary artery disease, percutaneous coronary artery procedures have become even more important. Our study has compared transradial to transfemoral artery approach for coronary procedures in Indian population. Comparison of transradial and transfemoral artery approach for percutaneous coronary procedures. 26,238 patients, who underwent percutaneous coronary artery procedures, were divided into two groups depending upon transradial and transfemoral artery approach and compared for the various demographic and clinical characteristics, risk factors profile, vascular access and procedural details. 26,238 patients underwent percutaneous coronary procedures at our center. 81% were male and 19% were female. 55.65% and 44.35% procedures were done through transfemoral and transradial approach, respectively. 17,417 (66.38%) coronary angiographies were done, out of which 53.92% were transradial and 46.08% were transfemoral procedures. 8821 (33.62%) Percutaneous Transluminal Coronary Angioplasty (PTCA) were done, out of which 25.46% and 74.54% were done through transradial and transfemoral approach, respectively. Mean fluoroscopy time was 4.40 ± 3.55 min for transradial and 3.30 ± 3.66 min for transfemoral CAG (p < 0.001). For PTCA mean fluoroscopy time was 13.53 ± 2.53 min for transradial and 12.61 ± 9.524 min for transfemoral PTCA (p < 0.001). Minor and major procedure related complications and total duration of hospital stay were lower in transradial as compared to transfemoral group. The number of percutaneous transradial procedures have increased significantly with reduced complication rates and comparable success rate to transfemoral approach, along with the additional benefits to patient in terms of patient comfort, preference and reduced cost of health delivery. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Strain measurements by fiber Bragg grating sensors for in situ pile loading tests
NASA Astrophysics Data System (ADS)
Schmidt-Hattenberger, Cornelia; Straub, Tilmann; Naumann, Marcel; Borm, Günter; Lauerer, Robert; Beck, Christoph; Schwarz, Wolfgang
2003-07-01
A fiber Bragg grating (FBG) sensor network has been installed into a large diameter concrete pile on a real construction site. The intention was to monitor its deformation behavior during several quasi-static loading cycles. The skin friction between pile and subsoil affecting the ultimate bearing capacity of the pile as well as the settlement behavior of the structure under investigation has been derived from our measurements. A comparison between the results of the fiber Bragg grating sensors and conventional concrete strain gages (CSG) has shown excellent correspondence.
Experimental Analyses of Yellow Tuff Spandrels of Post-medieval Buildings in the Naples Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calderoni, B.; Cordasco, E. A.; Lenza, P.
2008-07-08
Experimental analyses have been carried out on tuff masonry specimens in order to investigate the structural behaviour of historical buildings in the Naples area (Southern Italy). Spandrels of post-medieval buildings (late XVI to early XX century) have been analysed, with emphasis on morphological characteristics according to chronological indicators. Results of the experimentation on scaled models (1:10) are discussed and the better behaviour of historical masonry typologies on respect to the modern one is highlighted. Comparison with theoretical formulations of ultimate shear resistance are provided too.
Student Measurements of the Double Star Eta Cassiopeiae
NASA Astrophysics Data System (ADS)
Brewer, Mark; Cacace, Gabriel; Do, Vivian; Griffith, Nicholas; Malan, Alexandria; Paredes, Hanna; Peticolas, Brian; Stasiak, Kathryne
2016-10-01
The double star Eta Cassiopeiae was measured at Vanguard Preparatory School. Digital measurements were made with a 14-inch telescope equipped with a CCD camera. The plate scale was determined to be 0.50 arcseconds per pixel. The separations and position angles were determined to be 13.3 arcseconds and 340.4 degrees, by the use of astronomy software. Previous observations reported in the Washington Double Star Catalog were used as a comparison. The camera angle was found to be the ultimate issue in the skewed data gathered for the double star.
NASA Technical Reports Server (NTRS)
Dapremont. A.; Allen, C.; Runyon, C.
2014-01-01
Gale is a Late Noachian/Early Hesperian impact crater located on the dichotomy boundary separating the southern highlands and the northern lowlands of Mars. NASA's Curiosity Rover is currently exploring Gale, searching for evidence of habitability early in Mars history. With an approximate diameter of 155 km, and a approx. 5 km central mound informally titled Mt. Sharp, Gale represents a region of geologic interest due to the abundance of knowledge that can be derived, through its sedimentary deposits, pertaining to the environmental evolution of Mars. This study was undertaken to compare wind erosional features in Gale Crater and within sediments in a 1000 km radial area. The ultimate objective of this comparison was to determine if or how Gale relates to the surrounding region.
Effects of joint configuration for the arc welding of cast Ti-6Al-4V alloy rods in argon.
Taylor, J C; Hondrum, S O; Prasad, A; Brodersen, C A
1998-03-01
Titanium and its alloys are more commonly used in prosthodontics and welding has become the most common modality for their joining. Studies on the welding of titanium and its alloys have not quantified this value, though its importance has been suggested. This study compared the strength and properties of the joint achieved at various butt joint gaps by the arc-welding of cast Ti-6Al-4V alloy tensile bars in an argon atmosphere. Forty of 50 specimens were sectioned and welded at four gaps. All specimens underwent tensile testing to determine ultimate tensile strength and percentage elongation, then oxygen analysis and scanning electron microscopy. As no more than 3 samples in any group of 10 actually fractured in the weld itself, a secondary analysis that involved fracture location was initiated. There were no differences in ultimate tensile strength or percentage elongation between specimens with weld gaps of 0.25, 0.50, 0.75, and 1.00 mm and the as-cast specimens. There were no differences in ultimate tensile strength between specimens fracturing in the weld and those fracturing in the gauge in welded specimens; however, as-cast specimens demonstrated a higher ultimate tensile strength than welded specimens that fractured in the weld. Specimens that fractured in the weld site demonstrated less ductility than those that fractured in the gauge in both welded and as-cast specimens, as confirmed by scanning electron microscopy examination. The weld wire showed an oxygen scavenging effect from the as-cast parent alloy. The effects of the joint gap were not significant, whereas the characteristics of the joint itself were, which displayed slightly lower strength and significantly lower ductility (and thus decreased toughness). The arc-welding of cast titanium alloy in argon atmosphere appears to be a reliable and efficient prosthodontic laboratory modality producing predictable results, although titanium casting and joining procedures must be closely controlled to minimize heat effects and oxygen contamination.
Rats' Memory for Time and Relational Responding in the Duration-Comparison Procedure
ERIC Educational Resources Information Center
Santi, Angelo; Hoover, Claire; Simmons, Sabrina
2011-01-01
Rats were trained in a duration-comparison task to press one lever if the comparison duration ("c") was 1.2-s shorter than a standard duration ("s"), and another lever if c was 1.2-s longer than s. The interval between s and c duration was 1 s. The 10 duration pairs used during training controlled for the absolute duration of "c" and the total…
NASA Astrophysics Data System (ADS)
Koo, A.; Clare, J. F.
2012-06-01
Analysis of CIPM international comparisons is increasingly being carried out using a model-based approach that leads naturally to a generalized least-squares (GLS) solution. While this method offers the advantages of being easier to audit and having general applicability to any form of comparison protocol, there is a lack of consensus over aspects of its implementation. Two significant results are presented that show the equivalence of three differing approaches discussed by or applied in comparisons run by Consultative Committees of the CIPM. Both results depend on a mathematical condition equivalent to the requirement that any two artefacts in the comparison are linked through a sequence of measurements of overlapping pairs of artefacts. The first result is that a GLS estimator excluding all sources of error common to all measurements of a participant is equal to the GLS estimator incorporating all sources of error, including those associated with any bias in the standards or procedures of the measuring laboratory. The second result identifies the component of uncertainty in the estimate of bias that arises from possible systematic effects in the participants' measurement standards and procedures. The expression so obtained is a generalization of an expression previously published for a one-artefact comparison with no inter-participant correlations, to one for a comparison comprising any number of repeat measurements of multiple artefacts and allowing for inter-laboratory correlations.
A different type of 'glue ear': report of an unusual case of prominent ears.
Purcell, Elizabeth M; O'Neill, Ann C; Regan, Padraic J
2003-09-01
Prominent ears is a condition that can cause extreme psychological distress in young people. This cosmetic deformity can be corrected by otoplasty, an outpatient surgical procedure that is associated with a high rate of patient satisfaction. We report the unusual case of a teenage boy who had repeatedly applied cyanoacrylate adhesive ("superglue") to his postauricular skin in an attempt to pin back his prominent ears. This case of "glue ear" was ultimately resolved by successful otoplasty, although the residual effects of the glue resulted in delayed healing of the surgical wound.
Application of the Lucy–Richardson Deconvolution Procedure to High Resolution Photoemission Spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rameau, J.; Yang, H.-B.; Johnson, P.D.
2010-07-01
Angle-resolved photoemission has developed into one of the leading probes of the electronic structure and associated dynamics of condensed matter systems. As with any experimental technique the ability to resolve features in the spectra is ultimately limited by the resolution of the instrumentation used in the measurement. Previously developed for sharpening astronomical images, the Lucy-Richardson deconvolution technique proves to be a useful tool for improving the photoemission spectra obtained in modern hemispherical electron spectrometers where the photoelectron spectrum is displayed as a 2D image in energy and momentum space.
Detecting ionizing radiation with optical fibers down to biomedical doses
NASA Astrophysics Data System (ADS)
Avino, S.; D'Avino, V.; Giorgini, A.; Pacelli, R.; Liuzzi, R.; Cella, L.; De Natale, P.; Gagliardi, G.
2013-10-01
We report on a passive ionizing radiation sensor based on a fiber-optic resonant cavity interrogated by a high resolution interferometric technique. After irradiation in clinical linear accelerators, we observe significant variations of the fiber thermo-optic coefficient. Exploiting this effect, we demonstrate an ultimate detection limit of 160 mGy with an interaction volume of only 6 × 10-4 mm3. Thanks to its reliability, compactness, and sensitivity at biomedical dose levels, our system lends itself to real applications in radiation therapy procedures as well as in radiation monitoring and protection in medicine, aerospace, and nuclear power plants.
Dynamic Stability Instrumentation System (DSIS). Volume 3; User Manual
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.; Boyden, Richmond P.; Dress, David A.; Jordan, Thomas L.
1996-01-01
The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.
An investigation to improve selenodetic control through surface and orbital lunar photography
NASA Technical Reports Server (NTRS)
Sweet, H. J., III
1970-01-01
The use of lunar surface photography to achieve the photogrammetric transfer of available selenographic coordinates from future lunar landing sites to neighboring, photoidentifiable features was investigated. It can be implied from the procedures developed that overhead photography, were it available, could be utilized and would provide a material strengthening of the total solution. By the methodic selection of features and confirmation that they can in reality be identified from orbital photography, a modest selenodetic control system can be expanded into a net that could ultimately control all future, manned or unmanned, orbital photographic missions.
Perineal Hernia Is an Unusual Complication Post Perineal Bladder Neck Closure: A Case Report.
Omar, Helmy; Helmy, Tamer E; Hafez, Ashraf T; Dawaba, Mohamed E
2017-03-01
Bladder neck closure (BNC) is the ultimate bladder neck reconstruction. If reconstruction fails, closure must be considered as it gives the highest continence rate. The vast majority of BNCs are performed through an abdominal approach (either transvesical or extravesical approach), but perineal approach remains an option for BNC with considerable success rate. Perineal hernia, which is defined as protrusion of abdominal contents through the perineal defect, is a very rare complication after urologic procedures. We report a case of perineal hernia post perineal BNC. Copyright © 2016 Elsevier Inc. All rights reserved.
Xeroderma pigmentosum with melanoma of face and its prosthetic management.
Sadaf, Ayesha; Yazdanie, Nazia
2013-10-01
Xeroderma pigmentosum is a rare genetic disorder, characterized by cutaneous, ocular and neurological symptoms. Squamous cell carcinoma and melanoma are also its secondary characters. This case report is about maxillofacial prosthetic management of a 10 years old child presented with xeroderma pigmentosum. The nose of the patient was excised surgically due to melanoma. This case report elaborates the role of prosthodontist and the whole procedure of constructing the nasal prosthesis via conventional technique by using the patient's sibling nasal form as template. Regular follow up revealed marked improvement in esthetics, function and ultimately patient's quality of life.
Texture Modification of the Shuttle Landing Facility Runway at the NASA Kennedy Space Center
NASA Technical Reports Server (NTRS)
Daugherty, Robert H.; Yager, Thomas J.
1996-01-01
This paper describes the test procedures and the selection criteria used in selecting the best runway surface texture modification at the Kennedy Space Center (KSC) Shuttle Landing Facility (SLF) to reduce Orbiter tire wear. The new runway surface may ultimately result in an increase of allowable crosswinds for launch and landing operations. The modification allows launch and landing operations in 20-kt crosswinds if desired. This 5-kt increase over the previous 15-kt limit drastically increases landing safety and the ability to make on-time launches to support missions where space station rendezvous is planned.
NASA Technical Reports Server (NTRS)
1981-01-01
The objectives, procedures, accomplishments, plans, and ultimate uses of information from current projects at the Mississippi Remote Sensing Center are discussed for the following applications: (1) land use planning; (2) strip mine inventory and reclamation; (3) biological management for white tailed deer; (4) forest habitats in potential lignite areas; (5) change discrimination in gravel operations; (6) discrimination of freshwater wetlands for inventory and monitoring; and (7) remote sensing data analysis support systems. The initiation of a conceptual design for a LANDSAT based, state wide information system is proposed.
Herkert, Lorena; Green, Samantha L J; Barker, Graeme; Johnson, David G; Young, Paul C; Macgregor, Stuart A; Lee, Ai-Lan
2014-01-01
A gold(I)-catalysed direct thioetherification reaction between allylic alcohols and thiols is presented. The reaction is generally highly regioselective (SN2′). This dehydrative allylation procedure is very mild and atom economical, producing only water as the by-product and avoiding any unnecessary waste/steps associated with installing a leaving or activating group on the substrate. Computational studies are presented to gain insight into the mechanism of the reaction. Calculations indicate that the regioselectivity is under equilibrium control and is ultimately dictated by the thermodynamic stability of the products. PMID:25080400
Manufacturing techniques for gyroscopes in gravity probe B
NASA Technical Reports Server (NTRS)
Rasquin, J. R.
1976-01-01
The design of the fused silica gyroscope configuration is presented. The first gyroscope was made for erection and spin tests only and does not contain the angle readout loops necessary for a functioning experimental gyroscope. The rotor ball described is not coated with the ultimate material, niobium, but instead with a sandwich of titanium, cooper, and titanium for spin-up test purposes. Background, historical information, manufacturing procedures, and sketches for this gyroscope are included to provide a better understanding of the device and the techniques and special tools required to manufacture a fused silica gyroscope to the required specifications.
Comparison of procedure coding systems for level 1 and 2 hospitals in South Africa.
Montewa, Lebogang; Hanmer, Lyn; Reagon, Gavin
2013-01-01
The ability of three procedure coding systems to reflect the procedure concepts extracted from patient records from six hospitals was compared, in order to inform decision making about a procedure coding standard for South Africa. A convenience sample of 126 procedure concepts was extracted from patient records at three level 1 hospitals and three level 2 hospitals. Each procedure concept was coded using ICPC-2, ICD-9-CM, and CCSA-2001. The extent to which each code assigned actually reflected the procedure concept was evaluated (between 'no match' and 'complete match'). For the study sample, CCSA-2001 was found to reflect the procedure concepts most completely, followed by ICD-9-CM and then ICPC-2. In practice, decision making about procedure coding standards would depend on multiple factors in addition to coding accuracy.
Simultaneous Inference Procedures for Means.
ERIC Educational Resources Information Center
Krishnaiah, P. R.
Some aspects of simultaneous tests for means are reviewed. Specifically, the comparison of univariate or multivariate normal populations based on the values of the means or mean vectors when the variances or covariance matrices are equal is discussed. Tukey's and Dunnett's tests for multiple comparisons of means, Scheffe's method of examining…
A Fiducial Approach to Extremes and Multiple Comparisons
ERIC Educational Resources Information Center
Wandler, Damian V.
2010-01-01
Generalized fiducial inference is a powerful tool for many difficult problems. Based on an extension of R. A. Fisher's work, we used generalized fiducial inference for two extreme value problems and a multiple comparison procedure. The first extreme value problem is dealing with the generalized Pareto distribution. The generalized Pareto…
Sportswear textiles emissivity measurement: comparison of IR thermography and emissometry techniques
NASA Astrophysics Data System (ADS)
Bison, P.; Grinzato, E.; Libbra, A.; Muscio, A.
2012-06-01
Three sportswear textiles are compared, one normal and two 'special' with Ag+ ions and Carbon powder added, with different colors. The emissivity of the textiles has been measured to determine if it is increased in the 'special' textiles with respect to the normal one. The test implied some non-standard procedure due to the semitransparent nature of the textiles, in comparison with the normal procedure that is commonly used on opaque surfaces. The test is also carried out by a standard emissometry technique, based on a comparative approach with reference samples having known thermal emissivity. The results are compared and discussed.
Results of the first provisional technical secretariat interlaboratory comparison test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuff, J.R.; Hoffland, L.
1995-06-01
The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.
Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.
Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke
2015-12-01
Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.
Farer, Leslie J; Hayes, John M
2005-01-01
A new method has been developed for the determination of emamectin benzoate in fish feed. The method uses a wet extraction, cleanup by solid-phase extraction, and quantitation and separation by liquid chromatography (LC). In this paper, we compare the performance of this method with that of a previously reported LC assay for the determination of emamectin benzoate in fish feed. Although similar to the previous method, the new procedure uses a different sample pretreatment, wet extraction, and quantitation method. The performance of the new method was compared with that of the previously reported method by analyses of 22 medicated feed samples from various commercial sources. A comparison of the results presented here reveals slightly lower assay values obtained with the new method. Although a paired sample t-test indicates the difference in results is significant, this difference is within the method precision of either procedure.
Segmented Domain Decomposition Multigrid For 3-D Turbomachinery Flows
NASA Technical Reports Server (NTRS)
Celestina, M. L.; Adamczyk, J. J.; Rubin, S. G.
2001-01-01
A Segmented Domain Decomposition Multigrid (SDDMG) procedure was developed for three-dimensional viscous flow problems as they apply to turbomachinery flows. The procedure divides the computational domain into a coarse mesh comprised of uniformly spaced cells. To resolve smaller length scales such as the viscous layer near a surface, segments of the coarse mesh are subdivided into a finer mesh. This is repeated until adequate resolution of the smallest relevant length scale is obtained. Multigrid is used to communicate information between the different grid levels. To test the procedure, simulation results will be presented for a compressor and turbine cascade. These simulations are intended to show the ability of the present method to generate grid independent solutions. Comparisons with data will also be presented. These comparisons will further demonstrate the usefulness of the present work for they allow an estimate of the accuracy of the flow modeling equations independent of error attributed to numerical discretization.
ERIC Educational Resources Information Center
Mun, Eun Young; von Eye, Alexander; Bates, Marsha E.; Vaschillo, Evgeny G.
2008-01-01
Model-based cluster analysis is a new clustering procedure to investigate population heterogeneity utilizing finite mixture multivariate normal densities. It is an inferentially based, statistically principled procedure that allows comparison of nonnested models using the Bayesian information criterion to compare multiple models and identify the…
Group Comparisons in the Presence of Missing Data Using Latent Variable Modeling Techniques
ERIC Educational Resources Information Center
Raykov, Tenko; Marcoulides, George A.
2010-01-01
A latent variable modeling approach for examining population similarities and differences in observed variable relationship and mean indexes in incomplete data sets is discussed. The method is based on the full information maximum likelihood procedure of model fitting and parameter estimation. The procedure can be employed to test group identities…
Comparison of Two Procedures for Analyzing Small Sets of Repeated Measures Data
ERIC Educational Resources Information Center
Vallejo, Guillermo; Livacic-Rojas, Pablo
2005-01-01
This article compares two methods for analyzing small sets of repeated measures data under normal and non-normal heteroscedastic conditions: a mixed model approach with the Kenward-Roger correction and a multivariate extension of the modified Brown-Forsythe (BF) test. These procedures differ in their assumptions about the covariance structure of…
A Comparison of Procedures for Content-Sensitive Item Selection in Computerized Adaptive Tests.
ERIC Educational Resources Information Center
Kingsbury, G. Gage; Zara, Anthony R.
1991-01-01
This simulation investigated two procedures that reduce differences between paper-and-pencil testing and computerized adaptive testing (CAT) by making CAT content sensitive. Results indicate that the price in terms of additional test items of using constrained CAT for content balancing is much smaller than that of using testlets. (SLD)
A Comparison of Exposure Control Procedures in CATS Using the GPC Model
ERIC Educational Resources Information Center
Leroux, Audrey J.; Dodd, Barbara G.
2016-01-01
The current study compares the progressive-restricted standard error (PR-SE) exposure control method with the Sympson-Hetter, randomesque, and no exposure control (maximum information) procedures using the generalized partial credit model with fixed- and variable-length CATs and two item pools. The PR-SE method administered the entire item pool…
Comparison of IRT Likelihood Ratio Test and Logistic Regression DIF Detection Procedures
ERIC Educational Resources Information Center
Atar, Burcu; Kamata, Akihito
2011-01-01
The Type I error rates and the power of IRT likelihood ratio test and cumulative logit ordinal logistic regression procedures in detecting differential item functioning (DIF) for polytomously scored items were investigated in this Monte Carlo simulation study. For this purpose, 54 simulation conditions (combinations of 3 sample sizes, 2 sample…
ERIC Educational Resources Information Center
Brino, Ana Leda F., Barros, Romariz S., Galvao, Ol; Garotti, M.; Da Cruz, Ilara R. N.; Santos, Jose R.; Dube, William V.; McIlvane, William J.
2011-01-01
This paper reports use of sample stimulus control shaping procedures to teach arbitrary matching-to-sample to 2 capuchin monkeys ("Cebus apella"). The procedures started with identity matching-to-sample. During shaping, stimulus features of the sample were altered gradually, rendering samples and comparisons increasingly physically dissimilar. The…
Performance of conventionally powered vehicles tested to an electric vehicle test procedure
NASA Technical Reports Server (NTRS)
Slavik, R. J.; Dustin, M. O.; Lumannick, S.
1977-01-01
A conventional Volkswagen transporter, a Renault 5, a Pacer, and a U. S. Postal Service general DJ-5 delivery van were treated to an electric vehicle test procedure in order to allow direct comparison of conventional and electric vehicles. Performance test results for the four vehicles are presented.
ERIC Educational Resources Information Center
Lix, Lisa M.; Algina, James; Keselman, H. J.
2003-01-01
The approximate degrees of freedom Welch-James (WJ) and Brown-Forsythe (BF) procedures for testing within-subjects effects in multivariate groups by trials repeated measures designs were investigated under departures from covariance homogeneity and normality. Empirical Type I error and power rates were obtained for least-squares estimators and…
Comparison of proposed survey procedures for detection of forest carnivores
Kerry R. Foresman; Dean E. Pearson
1998-01-01
American marten (Martes americana), fisher (M. pennanti), wolverine (Gulo gulo), and lynx (Lynx lynx) are forest carnivores believed threatened by disturbance of late-successional forests. To manage forested ecosystems for these species, effective methods for their detection must be available. Recently, the U.S. Forest Service proposed standardized survey procedures...
A Comparison of Simultaneous Prompting and Constant Time Delay Procedures in Teaching State Capitals
ERIC Educational Resources Information Center
Head, Kenneth David; Collins, Belva C.; Schuster, John W.; Ault, Melinda Jones
2011-01-01
This investigation compared the effectiveness and efficiency of constant time delay (CTD) and simultaneous prompting (SP) procedures in teaching discrete social studies facts to 4 high school students with learning and behavior disorders using an adapted alternating treatments design nested within a multiple probe design. The results indicated…
Patient and family attitudes regarding the practice of procedures on the newly deceased.
Manifold, C A; Storrow, A; Rodgers, K
1999-02-01
Performance of emergency lifesaving procedures is an integral part of emergency medicine resident training. To assess attitudes of ED patients regarding the practice of procedures on the newly deceased. A descriptive survey was administered to a convenience sample of ED patients and their families at two urban military Level-1 trauma centers. Subjects were asked about their overall opinions regarding the practice of nontherapeutic procedural skills on themselves or relatives immediately after death in the ED. Subgroup analysis included the issue of advanced permission and opinions regarding procedures defined by the investigators as noninvasive (e.g., laryngeal mask airway) or invasive (e.g., cricothyrotomy). Data were analyzed descriptively and with chi-square as appropriate. For comparison of proportions, a sample size of at least 140 was chosen for an alpha of 0.05 and a beta of 0.10 to detect an effect size of 0.3. Alpha was corrected for multiple comparisons prior to the study. Three hundred seventeen surveys were collected and 88% (n = 280) were complete. Seventy-five percent (n = 290) and 70% (n = 273) of the respondents agreed to after-death procedures on themselves or their relatives, respectively. However, only 40% (n = 106) and 50% (n = 131) would allow such procedures without prior permission. Seventy-one percent (n = 189) were willing to give permission in a living will, while 85% (n = 238) indicated support of a wallet card format. There was no significant difference in permission rates when contrasting individual noninvasive and invasive procedures. Most patients are willing to have procedures performed on themselves or relatives shortly after death, yet the majority request that permission be obtained in advance. A living will or carried card would be acceptable for such permission.
2016-01-01
DC) product following cutaneous exposure to VX was affected by the DC procedure. Fur-clipped, male, unanesthetized guinea pigs were used as subjects...RSDL) Following Cutaneous VX Exposure in Guinea Pigs Irwin Koplovitz Susan Schulz Julia Morgan Robert Reed Edward Clarkson C. Gary Hurst...Decontamination Procedures Using Reactive Skin 5a. CONTRACT NUMBER Decontamination Lotion (RSDL) Following Cutaneous VX Exposure in Guinea Pigs 5b
Methodology for estimation of total body composition in laboratory mammals
NASA Technical Reports Server (NTRS)
Pace, N.; Rahlmann, D. F.; Smith, A. H.
1979-01-01
A standardized dissection and chemical analysis procedure was developed for individual animals of several species in the size range mouse to monkey (15 g to 15 kg). The standardized procedure permits rigorous comparisons to be made both interspecifically and intraspecifically of organ weights and gross chemical composition in mammalian species series, and was applied successfully to laboratory mice, hamsters, rats, guinea pigs, and rabbits, as well as to macaque monkeys. The procedure is described in detail.
A statistically robust EEG re-referencing procedure to mitigate reference effect
Lepage, Kyle Q.; Kramer, Mark A.; Chu, Catherine J.
2014-01-01
Background The electroencephalogram (EEG) remains the primary tool for diagnosis of abnormal brain activity in clinical neurology and for in vivo recordings of human neurophysiology in neuroscience research. In EEG data acquisition, voltage is measured at positions on the scalp with respect to a reference electrode. When this reference electrode responds to electrical activity or artifact all electrodes are affected. Successful analysis of EEG data often involves re-referencing procedures that modify the recorded traces and seek to minimize the impact of reference electrode activity upon functions of the original EEG recordings. New method We provide a novel, statistically robust procedure that adapts a robust maximum-likelihood type estimator to the problem of reference estimation, reduces the influence of neural activity from the re-referencing operation, and maintains good performance in a wide variety of empirical scenarios. Results The performance of the proposed and existing re-referencing procedures are validated in simulation and with examples of EEG recordings. To facilitate this comparison, channel-to-channel correlations are investigated theoretically and in simulation. Comparison with existing methods The proposed procedure avoids using data contaminated by neural signal and remains unbiased in recording scenarios where physical references, the common average reference (CAR) and the reference estimation standardization technique (REST) are not optimal. Conclusion The proposed procedure is simple, fast, and avoids the potential for substantial bias when analyzing low-density EEG data. PMID:24975291
Bosman, Lisa B; Darling, Seth B
2018-06-01
The advent of modern solar energy technologies can improve the costs of energy consumption on a global, national, and regional level, ultimately spanning stakeholders from governmental entities to utility companies, corporations, and residential homeowners. For those stakeholders experiencing the four seasons, accurately accounting for snow-related energy losses is important for effectively predicting photovoltaic performance energy generation and valuation. This paper provides an examination of a new, simplified approach to decrease snow-related forecasting error, in comparison to current solar energy performance models. A new method is proposed to allow model designers, and ultimately users, the opportunity to better understand the return on investment for solar energy systems located in snowy environments. The new method is validated using two different sets of solar energy systems located near Green Bay, WI, USA: a 3.0-kW micro inverter system and a 13.2-kW central inverter system. Both systems were unobstructed, facing south, and set at a tilt of 26.56°. Data were collected beginning in May 2014 (micro inverter system) and October 2014 (central inverter system), through January 2018. In comparison to reference industry standard solar energy prediction applications (PVWatts and PVsyst), the new method results in lower mean absolute percent errors per kilowatt hour of 0.039 and 0.055%, respectively, for the micro inverter system and central inverter system. The statistical analysis provides support for incorporating this new method into freely available, online, up-to-date prediction applications, such as PVWatts and PVsyst.
Kerwin, Leonard Y; El Tal, Abdel Kader; Stiff, Mark A; Fakhouri, Tarek M
2014-08-01
Cosmetic, functional, and structural sequelae of scarring are innumerable, and measures exist to optimize and ultimately minimize these sequelae. To evaluate the innumerable methods available to decrease the cosmetic, functional, and structural repercussions of scarring, pubMed search of the English literature with key words scar, scar revision, scar prevention, scar treatment, scar remodeling, cicatrix, cicatrix treatment, and cicatrix remodeling was done. Original articles and reviews were examined and included. Seventy-nine manuscripts were reviewed. Techniques, comparisons, and results were reviewed and tabulated. Overall, though topical modalities are easier to use and are usually more attractive to the patient, the surgical approaches still prove to be superior and more reliable. However, advances in topical medications for scar modification are on the rise and a change towards medical treatment of scars may emerge as the next best approach. Comparison studies of the innumerable specific modalities for scar revision and prevention are impossible. Standardization of techniques is lacking. Scarring, the body's natural response to a wound, can create many adverse effects. At this point, the practice of sound, surgical fundamentals still trump the most advanced preventative methods and revision techniques. Advances in medical approaches are available, however, to assist the scarring process, which even the most advanced surgical fundamentals will ultimately lead to. Whether through newer topical therapies, light treatment, or classical surgical intervention, our treatment armamentarium of scars has expanded and will allow us to maximize scar prevention and to minimize scar morbidity. © 2014 The International Society of Dermatology.
Efficacy and adverse events of cold vs hot polypectomy: A meta-analysis.
Fujiya, Mikihiro; Sato, Hiroki; Ueno, Nobuhiro; Sakatani, Aki; Tanaka, Kazuyuki; Dokoshi, Tatsuya; Fujibayashi, Shugo; Nomura, Yoshiki; Kashima, Shin; Gotoh, Takuma; Sasajima, Junpei; Moriichi, Kentaro; Watari, Jiro; Kohgo, Yutaka
2016-06-21
To compare previously reported randomized controlled studies (RCTs) of cold and hot polypectomy, we systematically reviewed and clarify the utility of cold polypectomy over hot with respect to efficacy and adverse events. A meta-analysis was conducted to evaluate the predominance of cold and hot polypectomy for removing colon polyps. Published articles and abstracts from worldwide conferences were searched using the keywords "cold polypectomy". RCTs that compared either or both the effects or adverse events of cold polypectomy with those of hot polypectomy were collected. The patients' demographics, endoscopic procedures, No. of examined lesions, lesion size, macroscopic and histologic findings, rates of incomplete resection, bleeding amount, perforation, and length of procedure were extracted from each study. A forest plot analysis was used to verify the relative strength of the effects and adverse events of each procedure. A funnel plot was generated to assess the possibility of publication bias. Ultimately, six RCTs were selected. No significant differences were noted in the average lesion size (less than 10 mm) between the cold and hot polypectomy groups in each study. Further, the rates of complete resection and adverse events, including delayed bleeding, did not differ markedly between cold and hot polypectomy. The average procedural time in the cold polypectomy group was significantly shorter than in the hot polypectomy group. Cold polypectomy is a time-saving procedure for removing small polyps with markedly similar curability and safety to hot polypectomy.
Postmining land use: economic comparison of forestry and pastureland alternatives
Charles H. Wolf
1980-01-01
The influence of soil properties, legal requirements, and economics on postmining land use is described, and enterprise budgets are prepared to demonstrate procedures for evaluating forest and pastureland alternatives. A comparison of cow-calf operations with hybrid poplar and black walnut plantations suggests that a combination of pastureland and black walnut...
COMPARISON OF WEST GERMAN AND U.S. FLUE GAS DESULFURIZATION AND SELECTIVE CATALYTIC REDUCTION COSTS
The report documents a comparison of the actual cost retrofitting flue gas desulfurization (FGD) and selective catalytic reduction (SCR) on Federal Republic of German (FRG) boilers to cost estimating procedures used in the U.S. to estimate the retrofit of these controls on U.S. b...
Comparison of Management Practices in Public and Private Universities in Khyber Pakhtunkhwa
ERIC Educational Resources Information Center
Khan, Nasrullah; Aajiz, Niaz Muhammad; Ali, Akber
2018-01-01
This study attempted to compare the management practices in public and private universities in Khyber Pakhtunkhawa, Pakistan. The comparison is based on availability of written rules and regulations, distribution of tasks, availability of managers, access to officers, time management, work load, staff promotion procedure and appraisal system.…
Hybrid computers and simulation languages in the study of dynamics of continuous systems
NASA Technical Reports Server (NTRS)
Acaccia, G. M.; Lucifredi, A. L.
1970-01-01
A comparison is presented of the use of hybrid computers and simulation languages as a means of studying the behavior of dynamic systems. Both procedures are defined and their advantages and disadvantages at the present state of the art are discussed. Some comparison and evaluation criteria are presented.
Matera, Camilla; Nerini, Amanda; Stefanile, Cristina
2018-06-16
The present research examined the roles of different forms of peer influence, internalization, social comparison, and body dissatisfaction in men's interest in cosmetic surgery. Participants were 204 Italian men (M age = 34.02, SD = 11.21). Regression analyses showed that appearance conversations with friends and peer attribution were associated with consideration of cosmetic surgery for social reasons, while teasing on muscularity (but not teasing on general body and shape) was linked to interest in cosmetic surgery for intrapersonal motives. Social comparison was significantly and positively associated with men's interest in cosmetic surgery, while internalization was not. Dissatisfaction with body fat was linked to men's consideration of cosmetic surgery for social motivations, while muscularity and height dissatisfaction did not emerge as significant correlates of cosmetic surgery attitudes. These findings highlight the importance of psychosocial factors, such as peer influence, body fat dissatisfaction, and social comparison in men's interest in cosmetic procedures. Copyright © 2018 Elsevier Ltd. All rights reserved.
Using video-oriented instructions to speed up sequence comparison.
Wozniak, A
1997-04-01
This document presents an implementation of the well-known Smith-Waterman algorithm for comparison of proteic and nucleic sequences, using specialized video instructions. These instructions, SIMD-like in their design, make possible parallelization of the algorithm at the instruction level. Benchmarks on an ULTRA SPARC running at 167 MHz show a speed-up factor of two compared to the same algorithm implemented with integer instructions on the same machine. Performance reaches over 18 million matrix cells per second on a single processor, giving to our knowledge the fastest implementation of the Smith-Waterman algorithm on a workstation. The accelerated procedure was introduced in LASSAP--a LArge Scale Sequence compArison Package software developed at INRIA--which handles parallelism at higher level. On a SUN Enterprise 6000 server with 12 processors, a speed of nearly 200 million matrix cells per second has been obtained. A sequence of length 300 amino acids is scanned against SWISSPROT R33 (1,8531,385 residues) in 29 s. This procedure is not restricted to databank scanning. It applies to all cases handled by LASSAP (intra- and inter-bank comparisons, Z-score computation, etc.
Quantification of Ice Accretions for Icing Scaling Evaluations
NASA Technical Reports Server (NTRS)
Ruff, Gary A.; Anderson, David N.
2003-01-01
The comparison of ice accretion characteristics is an integral part of aircraft icing research. It is often necessary to compare an ice accretion obtained from a flight test or numerical simulation to one produced in an icing wind tunnel or for validation of an icing scaling method. Traditionally, this has been accomplished by overlaying two-dimensional tracings of ice accretion shapes. This paper addresses the basic question of how to compare ice accretions using more quantitative methods. For simplicity, geometric characteristics of the ice accretions are used for the comparison. One method evaluated is a direct comparison of the percent differences of the geometric measurements. The second method inputs these measurements into a fuzzy inference system to obtain a single measure of the goodness of the comparison. The procedures are demonstrated by comparing ice shapes obtained in the Icing Research Tunnel at NASA Glenn Research Center during recent icing scaling tests. The results demonstrate that this type of analysis is useful in quantifying the similarity of ice accretion shapes and that the procedures should be further developed by expanding the analysis to additional icing data sets.
Integrated Data Collection Analysis (IDCA) Program - KClO 4/Carbon Mixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4/C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will putmore » the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less
Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M
2008-11-01
The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P < 0.001). The ultimate tensile strength in double-row specimens was significantly higher than in others (P < 0.001). There was no significant variation in using different suture material (P > 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.
NASA Astrophysics Data System (ADS)
Portal, A.; Labazuy, P.; Lénat, J.-F.; Béné, S.; Boivin, P.; Busato, E.; Cârloganu, C.; Combaret, C.; Dupieux, P.; Fehr, F.; Gay, P.; Laktineh, I.; Miallier, D.; Mirabito, L.; Niess, V.; Vulpescu, B.
2013-01-01
Muon imaging of volcanoes and of geological structures in general is actively being developed by several groups in the world. It has the potential to provide 3-D density distributions with an accuracy of a few percent. At this stage of development, comparisons with established geophysical methods are useful to validate the method. An experiment has been carried out in 2011 and 2012 on a large trachytic dome, the Puy de Dôme volcano, to perform such a comparison of muon imaging with gravimetric tomography and 2-D electrical resistivity tomography. Here, we present the preliminary results for the last two methods. North-south and east-west resistivity profiles allow us to model the resistivity distribution down to the base of the dome. The modelling of the Bouguer anomaly provides models for the density distribution within the dome that are directly comparable with the results from the muon imaging. Our ultimate goal is to derive a model of the dome using the joint interpretation of all sets of data.
Ground Truth Sampling and LANDSAT Accuracy Assessment
NASA Technical Reports Server (NTRS)
Robinson, J. W.; Gunther, F. J.; Campbell, W. J.
1982-01-01
It is noted that the key factor in any accuracy assessment of remote sensing data is the method used for determining the ground truth, independent of the remote sensing data itself. The sampling and accuracy procedures developed for nuclear power plant siting study are described. The purpose of the sampling procedure was to provide data for developing supervised classifications for two study sites and for assessing the accuracy of that and the other procedures used. The purpose of the accuracy assessment was to allow the comparison of the cost and accuracy of various classification procedures as applied to various data types.
NASA Technical Reports Server (NTRS)
Justice, C.; Townshend, J. (Principal Investigator)
1981-01-01
Two unsupervised classification procedures were applied to ratioed and unratioed LANDSAT multispectral scanner data of an area of spatially complex vegetation and terrain. An objective accuracy assessment was undertaken on each classification and comparison was made of the classification accuracies. The two unsupervised procedures use the same clustering algorithm. By on procedure the entire area is clustered and by the other a representative sample of the area is clustered and the resulting statistics are extrapolated to the remaining area using a maximum likelihood classifier. Explanation is given of the major steps in the classification procedures including image preprocessing; classification; interpretation of cluster classes; and accuracy assessment. Of the four classifications undertaken, the monocluster block approach on the unratioed data gave the highest accuracy of 80% for five coarse cover classes. This accuracy was increased to 84% by applying a 3 x 3 contextual filter to the classified image. A detailed description and partial explanation is provided for the major misclassification. The classification of the unratioed data produced higher percentage accuracies than for the ratioed data and the monocluster block approach gave higher accuracies than clustering the entire area. The moncluster block approach was additionally the most economical in terms of computing time.
NASA Astrophysics Data System (ADS)
Franck, Bas A. M.; Dreschler, Wouter A.; Lyzenga, Johannes
2004-12-01
In this study we investigated the reliability and convergence characteristics of an adaptive multidirectional pattern search procedure, relative to a nonadaptive multidirectional pattern search procedure. The procedure was designed to optimize three speech-processing strategies. These comprise noise reduction, spectral enhancement, and spectral lift. The search is based on a paired-comparison paradigm, in which subjects evaluated the listening comfort of speech-in-noise fragments. The procedural and nonprocedural factors that influence the reliability and convergence of the procedure are studied using various test conditions. The test conditions combine different tests, initial settings, background noise types, and step size configurations. Seven normal hearing subjects participated in this study. The results indicate that the reliability of the optimization strategy may benefit from the use of an adaptive step size. Decreasing the step size increases accuracy, while increasing the step size can be beneficial to create clear perceptual differences in the comparisons. The reliability also depends on starting point, stop criterion, step size constraints, background noise, algorithms used, as well as the presence of drifting cues and suboptimal settings. There appears to be a trade-off between reliability and convergence, i.e., when the step size is enlarged the reliability improves, but the convergence deteriorates. .
Horberry, Tim; Teng, Yi-Chun; Ward, James; Patil, Vishal; Clarkson, P John
2014-01-01
Central Venous Catheterisation (CVC) has occasionally been associated with cases of retained guidewires in patients after surgery. In theory, this is a completely avoidable complication; however, as with any human procedure, operator error leading to guidewires being occasionally retained cannot be fully eliminated. The work described here investigated the issue in an attempt to better understand it both from an operator and a systems perspective, and to ultimately recommend appropriate safe design solutions that reduce guidewire retention errors. Nine distinct methods were used: observations of the procedure, a literature review, interviewing CVC end-users, task analysis construction, CVC procedural audits, two human reliability assessments, usability heuristics and a comprehensive solution survey with CVC end-users. The three solutions that operators rated most highly, in terms of both practicality and effectiveness, were: making trainees better aware of the potential guidewire complications and strongly emphasising guidewire removal in CVC training, actively checking that the guidewire is present in the waste tray for disposal, and standardising purchase of central line sets so that differences that may affect chances of guidewire loss is minimised. Further work to eliminate/engineer out the possibility of guidewires being retained is proposed.
A Systematic Review of the Causes and Management of Ischaemic Stroke Caused by Nontissue Emboli
Judge, Ciaran; Mello, Sarah; Bradley, David
2017-01-01
Introduction The inadvertent or purposeful introduction of foreign bodies or substances can lead to cerebral infarction if they embolize to the brain. Individual reports of these events are uncommon but may increase with the increased occurrences of their risk factors, for example, intra-arterial procedures. Method We searched EMBASE and MEDLINE for articles on embolic stroke of nontissue origin. 1889 articles were identified and screened and 216 articles were ultimately reviewed in full text and included in qualitative analysis. Articles deemed relevant were assessed by a second reviewer to confirm compatibility with the inclusion criteria. References of included articles were reviewed for relevant publications. We categorized the pathology of the emboli into the following groups: air embolism (141 reports), other arterial gas embolisms (49 reports), missiles and foreign bodies (16 reports), and others, including drug embolism, cotton wool, and vascular sclerosant agents. Conclusion Air and gaseous embolism are becoming more common with increased use of interventional medical procedures and increased popularity of sports such as diving. There is increasing evidence for the use of hyperbaric oxygen for such events. Causes of solid emboli are diverse. More commonly reported causes include bullets, missiles, and substances used in medical procedures. PMID:29123937
A Systematic Review of the Causes and Management of Ischaemic Stroke Caused by Nontissue Emboli.
Judge, Ciaran; Mello, Sarah; Bradley, David; Harbison, Joseph
2017-01-01
The inadvertent or purposeful introduction of foreign bodies or substances can lead to cerebral infarction if they embolize to the brain. Individual reports of these events are uncommon but may increase with the increased occurrences of their risk factors, for example, intra-arterial procedures. We searched EMBASE and MEDLINE for articles on embolic stroke of nontissue origin. 1889 articles were identified and screened and 216 articles were ultimately reviewed in full text and included in qualitative analysis. Articles deemed relevant were assessed by a second reviewer to confirm compatibility with the inclusion criteria. References of included articles were reviewed for relevant publications. We categorized the pathology of the emboli into the following groups: air embolism (141 reports), other arterial gas embolisms (49 reports), missiles and foreign bodies (16 reports), and others, including drug embolism, cotton wool, and vascular sclerosant agents. Air and gaseous embolism are becoming more common with increased use of interventional medical procedures and increased popularity of sports such as diving. There is increasing evidence for the use of hyperbaric oxygen for such events. Causes of solid emboli are diverse. More commonly reported causes include bullets, missiles, and substances used in medical procedures.
Surgical management of obstructive sleep apnea in children with cerebral palsy.
Magardino, T M; Tom, L W
1999-10-01
To evaluate the surgical management of obstructive sleep apnea in children with cerebral palsy. Retrospective review of 27 children with cerebral palsy who underwent surgical treatment for obstructive sleep apnea. Charts were reviewed. Data gathered included primary complaint, coexisting illnesses, initial procedure performed, age at initial surgery, number of days the child was monitored postoperatively in the intensive care unit, notation of postoperative respiratory distress and management, and outcome. Nineteen children underwent adenotonsillectomy for initial treatment of obstructive sleep apnea. Three of these children also had a uvulectomy. Six children had an adenoidectomy alone as their initial procedure. Neither uvulopalatopharyngoplasty nor tracheostomy was performed as an initial procedure. Mean follow-up was 34 months. Seventy-six percent of these children have not required any further surgery. Of the six children who have undergone further surgery, one has required a revision adenoidectomy, and another underwent a tonsillectomy and uvulectomy 2 months after the initial adenoidectomy. Four children ultimately required a tracheotomy. Eighty-four percent of these children were successfully managed without a tracheotomy. We recommend tonsillectomy and/or adenoidectomy for initial surgical treatment of obstructive sleep apnea in children with cerebral palsy.
Wenke, A; Gaber, A; Hertle, L; Roeder, N; Pühse, G
2012-07-01
Precise and complete coding of diagnoses and procedures is of value for optimizing revenues within the German diagnosis-related groups (G-DRG) system. The implementation of effective structures for coding is cost-intensive. The aim of this study was to prove whether higher costs can be refunded by complete acquisition of comorbidities and complications. Calculations were based on DRG data of the Department of Urology, University Hospital of Münster, Germany, covering all patients treated in 2009. The data were regrouped and subjected to a process of simulation (increase and decrease of patient clinical complexity levels, PCCL) with the help of recently developed software. In urology a strong dependency of quantity and quality of coding of secondary diagnoses on PCCL and subsequent profits was found. Departmental budgetary procedures can be optimized when coding is effective. The new simulation tool can be a valuable aid to improve profits available for distribution. Nevertheless, calculation of time use and financial needs by this procedure are subject to specific departmental terms and conditions. Completeness of coding of (secondary) diagnoses must be the ultimate administrative goal of patient case documentation in urology.
Andreini, Claudia; Cavallaro, Gabriele; Rosato, Antonio; Valasatava, Yana
2013-11-25
We developed a new software tool, MetalS(2), for the structural alignment of Minimal Functional Sites (MFSs) in metal-binding biological macromolecules. MFSs are 3D templates that describe the local environment around the metal(s) independently of the larger context of the macromolecular structure. Such local environment has a determinant role in tuning the chemical reactivity of the metal, ultimately contributing to the functional properties of the whole system. On our example data sets, MetalS(2) unveiled structural similarities that other programs for protein structure comparison do not consistently point out and overall identified a larger number of structurally similar MFSs. MetalS(2) supports the comparison of MFSs harboring different metals and/or with different nuclearity and is available both as a stand-alone program and a Web tool ( http://metalweb.cerm.unifi.it/tools/metals2/).
NASA Technical Reports Server (NTRS)
Nielsen, Eric J.; Kleb, William L.
2005-01-01
A methodology is developed and implemented to mitigate the lengthy software development cycle typically associated with constructing a discrete adjoint solver for aerodynamic simulations. The approach is based on a complex-variable formulation that enables straightforward differentiation of complicated real-valued functions. An automated scripting process is used to create the complex-variable form of the set of discrete equations. An efficient method for assembling the residual and cost function linearizations is developed. The accuracy of the implementation is verified through comparisons with a discrete direct method as well as a previously developed handcoded discrete adjoint approach. Comparisons are also shown for a large-scale configuration to establish the computational efficiency of the present scheme. To ultimately demonstrate the power of the approach, the implementation is extended to high temperature gas flows in chemical nonequilibrium. Finally, several fruitful research and development avenues enabled by the current work are suggested.
Efficient Construction of Discrete Adjoint Operators on Unstructured Grids Using Complex Variables
NASA Technical Reports Server (NTRS)
Nielsen, Eric J.; Kleb, William L.
2005-01-01
A methodology is developed and implemented to mitigate the lengthy software development cycle typically associated with constructing a discrete adjoint solver for aerodynamic simulations. The approach is based on a complex-variable formulation that enables straightforward differentiation of complicated real-valued functions. An automated scripting process is used to create the complex-variable form of the set of discrete equations. An efficient method for assembling the residual and cost function linearizations is developed. The accuracy of the implementation is verified through comparisons with a discrete direct method as well as a previously developed handcoded discrete adjoint approach. Comparisons are also shown for a large-scale configuration to establish the computational efficiency of the present scheme. To ultimately demonstrate the power of the approach, the implementation is extended to high temperature gas flows in chemical nonequilibrium. Finally, several fruitful research and development avenues enabled by the current work are suggested.
NASA Astrophysics Data System (ADS)
Thubaasini, P.; Rusnida, R.; Rohani, S. M.
This paper describes Linux, an open source platform used to develop and run a virtual architectural walkthrough application. It proposes some qualitative reflections and observations on the nature of Linux in the concept of Virtual Reality (VR) and on the most popular and important claims associated with the open source approach. The ultimate goal of this paper is to measure and evaluate the performance of Linux used to build the virtual architectural walkthrough and develop a proof of concept based on the result obtain through this project. Besides that, this study reveals the benefits of using Linux in the field of virtual reality and reflects a basic comparison and evaluation between Windows and Linux base operating system. Windows platform is use as a baseline to evaluate the performance of Linux. The performance of Linux is measured based on three main criteria which is frame rate, image quality and also mouse motion.
Propeller aircraft interior noise model utilization study and validation
NASA Technical Reports Server (NTRS)
Pope, L. D.
1984-01-01
Utilization and validation of a computer program designed for aircraft interior noise prediction is considered. The program, entitled PAIN (an acronym for Propeller Aircraft Interior Noise), permits (in theory) predictions of sound levels inside propeller driven aircraft arising from sidewall transmission. The objective of the work reported was to determine the practicality of making predictions for various airplanes and the extent of the program's capabilities. The ultimate purpose was to discern the quality of predictions for tonal levels inside an aircraft occurring at the propeller blade passage frequency and its harmonics. The effort involved three tasks: (1) program validation through comparisons of predictions with scale-model test results; (2) development of utilization schemes for large (full scale) fuselages; and (3) validation through comparisons of predictions with measurements taken in flight tests on a turboprop aircraft. Findings should enable future users of the program to efficiently undertake and correctly interpret predictions.
Effect of a timebase mismatch in two-way optical frequency transfer
NASA Astrophysics Data System (ADS)
Tampellini, Anna; Clivati, Cecilia; Levi, Filippo; Mura, Alberto; Calonico, Davide
2017-12-01
Two-way frequency transfer on optical fibers is a powerful technique for the comparison of distant clocks over long and ultra-long hauls. In contrast to traditional Doppler noise cancellation, it is capable of sustaining higher link attenuation, mitigating the need of optical amplification and regeneration and thus reducing the setup complexity. We investigate the ultimate limitations of the two-way approach on a 300 km multiplexed fiber haul, considering fully independent setups and acquisition systems at the two link ends. We derive a theoretical model to predict the performance deterioration due to a bad synchronisation of the measurements, which is confirmed by experimental results. This study demonstrates that two-way optical frequency transfer is a reliable and performing technique, capable of sustaining remote clocks comparisons at the 10-19 resolution, and is relevant for the development of a fiber network of continental scale for frequency metrology in Europe.
Correcting for Indirect Range Restriction in Meta-Analysis: Testing a New Meta-Analytic Procedure
ERIC Educational Resources Information Center
Le, Huy; Schmidt, Frank L.
2006-01-01
Using computer simulation, the authors assessed the accuracy of J. E. Hunter, F. L. Schmidt, and H. Le's (2006) procedure for correcting for indirect range restriction, the most common type of range restriction, in comparison with the conventional practice of applying the Thorndike Case II correction for direct range restriction. Hunter et…
ERIC Educational Resources Information Center
Kangas, Brian D.; Branch, Marc N.
2012-01-01
The effects of cocaine were examined under a titrating-delay matching-to-sample procedure. In this procedure, the delay between sample stimulus offset and comparison stimuli onset adjusts as a function of the subject's performance. Specifically, matches increase the delay and mismatches decrease the delay. Titrated delay values served as the…
Gross-Motor Skill Acquisition by Preschool Dance Students under Self-Instruction Procedures
ERIC Educational Resources Information Center
Vintere, Parsla; Hemmes, Nancy S.; Brown, Bruce L.; Poulson, Claire L.
2004-01-01
The effects of two training procedures -- (a) modeling and praise and (b) self-instruction, modeling, and praise -- on complex gross-motor chain acquisition for preschool dance class students were evaluated. Six girls participated in the study. A multiple baseline design across six gross-motor chains with a secondary group comparison for treatment…
A Procedure for Testing the Difference between Effect Sizes.
ERIC Educational Resources Information Center
Lambert, Richard G.; Flowers, Claudia
A special case of the homogeneity of effect size test, as applied to pairwise comparisons of standardized mean differences, was evaluated. Procedures for comparing pairs of pretest to posttest effect sizes, as well as pairs of treatment versus control group effect sizes, were examined. Monte Carlo simulation was used to generate Type I error rates…
John G. King
1989-01-01
lncreases in annual streamflow and peak streamflows were determined on four small watersheds following timber harvesting and road building. The measured hydrologic changes are compared to those predicted by a methodology commonly used in the Forest Service's Northern Region, the equivalent clearcut area procedure. lncreases in peak streamflows are discussed with...
On zero variance Monte Carlo path-stretching schemes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lux, I.
1983-08-01
A zero variance path-stretching biasing scheme proposed for a special case by Dwivedi is derived in full generality. The procedure turns out to be the generalization of the exponential transform. It is shown that the biased game can be interpreted as an analog simulation procedure, thus saving some computational effort in comparison with the corresponding nonanalog game.
ERIC Educational Resources Information Center
Pozzulo, Joanna D.; Dempsey, Julie; Crescini, Charmagne
2009-01-01
Preschoolers' (3- to 6-year-olds) person description and identification abilities were examined using the simultaneous and elimination lineup procedures. Participants (N = 100) were exposed to a 20-minute mask-making session conducted by a female confederate who acted as the mask-making teacher. After a brief delay (20 min), participants were…
ERIC Educational Resources Information Center
Cole, Lawrence E.
The study paired-associate (PA) learning via the anticipation (ANT) and study-test (ST) procedures across second, third, fourth and fifth grades. Specifically, age differences in the rate of learning and examining PA learning according to the stage analyses were examined. Retention was also of interest: however, a ceiling effect negated the…
Factor Retention in Exploratory Factor Analysis: A Comparison of Alternative Methods.
ERIC Educational Resources Information Center
Mumford, Karen R.; Ferron, John M.; Hines, Constance V.; Hogarty, Kristine Y.; Kromrey, Jeffery D.
This study compared the effectiveness of 10 methods of determining the number of factors to retain in exploratory common factor analysis. The 10 methods included the Kaiser rule and a modified Kaiser criterion, 3 variations of parallel analysis, 4 regression-based variations of the scree procedure, and the minimum average partial procedure. The…
ERIC Educational Resources Information Center
Celik, Semiha; Vuran, Sezgin
2014-01-01
The purpose of this study was to compare the efficiency, effectiveness, maintenance effects and social validity of two instructional methods, Direct Instruction and Simultaneous Prompting Procedure, on teaching concepts (long, old, few and thick) using a parallel treatments design. All sessions were conducted at a private special education center…
ERIC Educational Resources Information Center
Akizuki, Kazunori; Ohashi, Yukari
2014-01-01
Purpose: The influence of attention on postural control and the relationship between attention and falling has been reported in previous studies. Although a dual-task procedure is commonly used to measure attentional demand, such procedures are affected by allocation policy, which is a mental strategy to divide attention between simultaneous…
A Comparison of Declarative and Hybrid Declarative-Procedural Models for Rover Operations
NASA Technical Reports Server (NTRS)
Knight, Russell; Rabideau, Gregg; Lenda, Matthew; Maldague, Pierre
2012-01-01
The MAPGEN [2] (Mixed-initiative Activity Plan GENerator) planning system is a great example of a hybrid procedural/declarative system where the advantages of each are leveraged to produce an effective planner/scheduler for Mars Exploration Rover tactical planning. We explore the adaptation of the same domain to an entirely declarative planning system (ASPEN [4] Activity Scheduling and Planning ENvironment), and demonstrate that, with some translation, much of the procedural knowledge encoding is amenable to a declarative knowledge encoding.
Consideration of dynamic loads on the vertical tail by the theory of flat yawing maneuvers
NASA Technical Reports Server (NTRS)
Boshar, John; Davis, Philip
1946-01-01
Dynamic yawing effects on vertical tail loads are considered by a theory of flat yawing maneuvers. A comparison is shown between computed loads and the loads measured in flight in a fighter airplane. The dynamic effects were investigated on a large flying boat for both an abrupt rudder deflection and a sinusoidal rudder deflection. Only a moderate amount of control deflection was found to be necessary to attain the ultimate design load on the tail. In order to take into account dynamic effects in design, specifications of yawing maneuverability or control movement are needed.
Mass-losing peculiar red giants - The comparison between theory and observations
NASA Technical Reports Server (NTRS)
Jura, M.
1989-01-01
The mass loss from evolved red giants is considered. It seems that red giants on the Asymptotic Giant Branch (AGB) are losing between 0.0003 and 0.0006 solar mass/sq kpc yr in the solar neighborhood. If all the main sequence stars between 1 and 5 solar masses ultimately evolve into white dwarfs with masses of 0.7 solar mass, the predicted mass loss rate in the solar neighborhood from these stars is 0.0008 solar mass/sq kpc yr. Although there are still uncertainties, it appears that there is no strong disagreement between theory and observation.
Rehabilitation and indigenous peoples: the Māori experience.
Harwood, Matire
2010-01-01
Indigenous peoples often have the worst health status in comparison to non-indigenous people in their own nations; urgent action to address the health inequities for indigenous people is required. The role of rehabilitation in addressing health and disability inequities is particularly important due to the health need of indigenous peoples; the unequal distribution of health determinants; and disparities in access to, quality of care through and outcomes following rehabilitation. This article will present a perspective for Māori, the indigenous peoples of New Zealand, on a framework for improving rehabilitation services for Māori and ultimately their health and wellbeing.
Efficiency equations of the railgun
NASA Astrophysics Data System (ADS)
Sadedin, D. R.
1984-03-01
The feasibility of an employment of railguns for large scale applications, such as space launching, will ultimately be determined by efficiency considerations. The present investigation is concerned with the calculation of the efficiencies for constant current railguns. Elementary considerations are discussed, taking into account a simple condition for high efficiency, the magnetic field of the rails, and the acceleration force on the projectile. The loss in a portion of the rails is considered along with rail loss comparisons, applications to the segmented gun, rail losses related to the constant resistance per unit length, efficiency expressions, and arc, or muzzle voltage energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroes, Maarten W., E-mail: Maarten.Kroes@radboudumc.nl; Busser, Wendy M. H.; Hoogeveen, Yvonne L.
PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355).more » The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.« less
Morán López, Jesús Manuel; Piedra León, María; Beneítez Moralejo, Belén; Enciso Izquierdo, Fidel Jesús; Luengo Pérez, Luis Miguel; Amado Señaris, José Antonio
2016-06-01
Disease Related Malnutrition (DRM) is highly prevalent in Spanish hospitals. WHO estimates that 20-40% of health-associated expenses are lost due to inefficiency. Demonstration that DRM is a component of inefficiency and hiring a specialist physician for its detection and treatment is cost-effective. Comparison between nutritional diagnosis and procedures detected and encoded at discharge using McNemar test. Recoding of 162 discharge reports including nutritional diagnoses and procedures. Determine changes on Case-Mix Index (IC), cost of procedure and cost procedure/DRG index. Comparison using T-student paired test. Only 10 of 162 diagnoses of malnutrition were coded in delivery statements (p < 0.001). After right codification, IC increased in 103,3 DRG points (p < 0.001). Consequently, procedure cost/DRG index was reduced in 978.81 € (p < 0.001). DRM is underdiagnosed in our hospital. DRM and nutritional procedures detection by a doctor specialist in clinical nutrition led to a reduction in cost procedure/DRG index of 16.8% of officially established by the Health System. Loss of 16.8% of health expenses, estimated in 424.785,15 € was described. Proper codification would have justified 343.291,2 € reimbursement just for nutritional diagnoses and processes. Both expenses were lost due to system's inefficiency. Those amounts are much higher than cost associated of hiring a specialist in clinical nutrition. Copyright © 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
Morán López, Jesús Manuel; Enciso Izquierdo, Fidel Jesús; Beneítez Moralejo, Belén; Luengo Pérez, Luis Miguel; Piedra León, María; Amado Señaris, José Antonio
2015-04-01
Disease Related Malnutrition (DRM) is highly prevalent in Spanish hospitals. WHO estimates that 20-40% of health-associated expenses are lost due to inefficiency. Demonstration that DRM is a component of inefficiency and hiring a specialist physician for its detection and treatment is cost-effective. Comparison between nutritional diagnosis and procedures detected and encoded at discharge using McNemar test. Recoding of 55 discharge reports including nutritional diagnoses and procedures. Determine changes on Case-Mix Index (IC), cost of procedure and cost procedure/GRD index. Comparison using Wilcoxon test. Only 2 of 55 diagnoses of malnutrition were coded in delivery statements (p<0,001). After right codification,IC increased in 42,67 GRD points (p<0,05). Consequently, procedure cost/GRD index was reduced in 976,81€ (p<0,05). DRM is underdiagnosed in our hospital. DRM and nutritional procedures detection by a specialist on endocrinology and nutrition led to a reduction in cost procedure/GRD index of 20% of officially established by the Health System. Loss of 20% of health expenses,estimated in 172690€ was described. Proper codification would have justified 154581€ reimbursement just for nutritional diagnoses and processes. Both expenses were lost due to system's inefficiency. Those amounts are much higher than cost associated of hiring a specialist, so there is no economic reason for denying it. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, J.C.
This report discusses the comparisons of a RELAP5 posttest calculation of the recovery portion of the Semiscale Mod-2B test S-SG-1 to the test data. The posttest calculation was performed with the RELAP5/MOD2 cycle 36.02 code without updates. The recovery procedure that was calculated mainly consisted of secondary feed and steam using auxiliary feedwater injection and the atmospheric dump valve of the unaffected steam generator (the steam generator without the tube rupture). A second procedure was initiated after the trends of the secondary feed and steam procedure had been established, and this was to stop the safety injection that had beenmore » provided by two trains of both the charging and high pressure injection systems. The Semiscale Mod-2B configuration is a small scale (1/1705), nonnuclear, instrumented, model of a Westinghouse four-loop pressurized water reactor power plant. S-SG-1 was a single-tube, cold-side, steam generator tube rupture experiment. The comparison of the posttest calculation and data included comparing the general trends and the driving mechanisms of the responses, the phenomena, and the individual responses of the main parameters.« less
NASA Astrophysics Data System (ADS)
Zhao, Shan; McNamara, Cameron T.; Bowen, Patrick K.; Verhun, Nicholas; Braykovich, Jacob P.; Goldman, Jeremy; Drelich, Jaroslaw W.
2017-03-01
Zinc shows great promise as a bioabsorbable metal; however, the low tensile strength of pure zinc limits its application for endovascular stent purposes. In this study, a new Zn- xLi alloy (with x = 2, 4, 6 at. pct) was prepared by induction melting in an argon atmosphere and processed through hot rolling. Structures of the formulated binary alloys were characterized by X-ray diffraction and optical microscopy. Mechanical testing showed that the incorporation of Li into Zn increased ultimate tensile strength from <120 MPa (pure Zn) to >560 MPa ( x = 6 at. pct). In vitro corrosion behavior was evaluated by immersion tests in simulated body fluid. The Zn-2Li and Zn-4Li corrosion study demonstrated that corrosion rates and products resemble those observed for pure Zn in vivo, and in addition, the Zn-4Li alloy exhibits higher resistance to corrosion as compared to Zn-2Li. The findings herein encourage further exploration of Zn-Li systems for structural use in biomedical vascular support applications with the ultimate goal of simplifying stent procedures, thereby reducing stent-related complications.
A computed microtomography method for understanding epiphyseal growth plate fusion
NASA Astrophysics Data System (ADS)
Staines, Katherine A.; Madi, Kamel; Javaheri, Behzad; Lee, Peter D.; Pitsillides, Andrew A.
2017-12-01
The epiphyseal growth plate is a developmental region responsible for linear bone growth, in which chondrocytes undertake a tightly regulated series of biological processes. Concomitant with the cessation of growth and sexual maturation, the human growth plate undergoes progressive narrowing, and ultimately disappears. Despite the crucial role of this growth plate fusion ‘bridging’ event, the precise mechanisms by which it is governed are complex and yet to be established. Progress is likely hindered by the current methods for growth plate visualisation; these are invasive and largely rely on histological procedures. Here we describe our non-invasive method utilising synchrotron x-ray computed microtomography for the examination of growth plate bridging, which ultimately leads to its closure coincident with termination of further longitudinal bone growth. We then apply this method to a dataset obtained from a benchtop microcomputed tomography scanner to highlight its potential for wide usage. Furthermore, we conduct finite element modelling at the micron-scale to reveal the effects of growth plate bridging on local tissue mechanics. Employment of these 3D analyses of growth plate bone bridging is likely to advance our understanding of the physiological mechanisms that control growth plate fusion.
Pilot training: What can surgeons learn from it?
Sommer, Kai-Jörg
2014-03-01
To provide healthcare professionals with an insight into training in aviation and its possible transfer into surgery. From research online and into company archives, relevant publications and information were identified. Current airline pilot training consists of two categories, basic training and type-rating. Training methods comprise classroom instruction, computer-based training and practical training, in either the aircraft or a flight-training device, which ranges from a fixed-base flight-training device to a full flight simulator. Pilot training not only includes technical and procedural instruction, but also training in non-technical skills like crisis management, decision-making, leadership and communication. Training syllabuses, training devices and instructors are internationally standardized and these standards are legally binding. Re-qualification and recurrent training are mandatory at all stages of a pilot's and instructor's career. Surgeons and pilots have much in common, i.e., they work in a 'real-time' three-dimensional environment under high physiological and psychological stress, operating expensive equipment, and the ultimate cost for error is measured in human lives. However, their training differs considerably. Transferring these well-tried aviation methods into healthcare will make surgical training more efficient, more effective and ultimately safer.
Fortuna, A O; Gurd, J R
1999-01-01
During certain medical procedures, it is important to continuously measure the respiratory flow of a patient, as lack of proper ventilation can cause brain damage and ultimately death. The monitoring of the ventilatory condition of a patient is usually performed with the aid of flowmeters. However, water and other secretions present in the expired air can build up and ultimately block a traditional, restriction-based flowmeter; by using an orifice plate flowmeter, such blockages are minimized. This paper describes the design of an orifice plate flowmetering system including, especially, a description of the numerical and computational techniques adopted in order to simulate human respiratory and sinusoidal air flow across various possible designs for the orifice plate flowmeter device. Parallel computation and multigrid techniques were employed in order to reduce execution time. The simulated orifice plate was later built and tested under unsteady sinusoidal flows. Experimental tests show reasonable agreement with the numerical simulation, thereby reinforcing the general hypothesis that computational exploration of the design space is sufficiently accurate to allow designers of such systems to use this in preference to the more traditional, mechanical prototyping techniques.
Immobilization in cement mortar of chromium removed from water using titania nanoparticles.
Husnain, Ahmed; Qazi, Ishtiaq Ahmed; Khaliq, Wasim; Arshad, Muhammad
2016-05-01
Because of the high toxicity of chromium, particularly as Cr (VI), it is removed from industrial effluents before their discharge into water bodies by a variety of techniques, including adsorption. Ultimate disposal of the sludge or the adsorbate, however, is a serious problem. While titania, in nanoparticle form, serves as a very good adsorbent for chromium, as an additive, it also helps to increase the compressive strength of mortar and concrete. Combining these two properties of the material, titania nanoparticles were used to adsorb chromium and then added to mortar up to a concentration of 20% by weight. The compressive strength of the resulting mortar specimens that replaced 15% of cement with chromium laden titania showed an improved strength than that without titania, thus confirming that this material had positive effect on the mortar strength. Leachate tests using the Toxicity Characteristics Leaching Procedure (TCLP) confirmed that the mortar sample chromium leachate was well within the permissible limits. The proposed technique thus offers a safe and viable method for the ultimate disposal of toxic metal wastes, in general, and those laden waste chromium, in particular. Copyright © 2016 Elsevier Ltd. All rights reserved.
A comparison of automated crater detection methods
NASA Astrophysics Data System (ADS)
Bandeira, L.; Barreira, C.; Pina, P.; Saraiva, J.
2008-09-01
Abstract This work presents early results of a comparison between some common methodologies for automated crater detection. The three procedures considered were applied to images of the surface of Mars, thus illustrating some pros and cons of their use. We aim to establish the clear advantages in using this type of methods in the study of planetary surfaces.
ERIC Educational Resources Information Center
Jaffery, Rose; Johnson, Austin H.; Bowler, Mark C.; Riley-Tillman, T. Chris; Chafouleas, Sandra M.; Harrison, Sayward E.
2015-01-01
To date, rater accuracy when using Direct Behavior Rating (DBR) has been evaluated by comparing DBR-derived data to scores yielded through systematic direct observation. The purpose of this study was to evaluate an alternative method for establishing comparison scores using expert-completed DBR alongside best practices in consensus building…
Neural Correlates of Encoding Predict Infants' Memory in the Paired-Comparison Procedure
ERIC Educational Resources Information Center
Snyder, Kelly A.
2010-01-01
The present study used event-related potentials (ERPs) to monitor infant brain activity during the initial encoding of a previously novel visual stimulus, and examined whether ERP measures of encoding predicted infants' subsequent performance on a visual memory task (i.e., the paired-comparison task). A late slow wave component of the ERP measured…
ERIC Educational Resources Information Center
Barrows, Russell D.
2007-01-01
A one-way ANOVA experiment is performed to determine whether or not the three standardization methods are statistically different in determining the concentration of the three paraffin analytes. The laboratory exercise asks students to combine the three methods in a single analytical procedure of their own design to determine the concentration of…
ERIC Educational Resources Information Center
Rittle-Johnson, Bethany; Star, Jon R.
2007-01-01
Encouraging students to share and compare solution methods is a key component of reform efforts in mathematics, and comparison is emerging as a fundamental learning mechanism. To experimentally evaluate the effects of comparison for mathematics learning, the authors randomly assigned 70 seventh-grade students to learn about algebra equation…
Tewari, Satyendra; Sharma, Naveen; Kapoor, Aditya; Syal, Sanjeev Kumar; Kumar, Sudeep; Garg, Naveen; Goel, Pravin K.
2013-01-01
Background With the increasing prevalence of coronary artery disease, percutaneous coronary artery procedures have become even more important. Our study has compared transradial to transfemoral artery approach for coronary procedures in Indian population. Aims and objective Comparison of transradial and transfemoral artery approach for percutaneous coronary procedures. Material & methods 26,238 patients, who underwent percutaneous coronary artery procedures, were divided into two groups depending upon transradial and transfemoral artery approach and compared for the various demographic and clinical characteristics, risk factors profile, vascular access and procedural details. Results 26,238 patients underwent percutaneous coronary procedures at our center. 81% were male and 19% were female. 55.65% and 44.35% procedures were done through transfemoral and transradial approach, respectively. 17,417 (66.38%) coronary angiographies were done, out of which 53.92% were transradial and 46.08% were transfemoral procedures. 8821 (33.62%) Percutaneous Transluminal Coronary Angioplasty (PTCA) were done, out of which 25.46% and 74.54% were done through transradial and transfemoral approach, respectively. Mean fluoroscopy time was 4.40 ± 3.55 min for transradial and 3.30 ± 3.66 min for transfemoral CAG (p < 0.001). For PTCA mean fluoroscopy time was 13.53 ± 2.53 min for transradial and 12.61 ± 9.524 min for transfemoral PTCA (p < 0.001). Minor and major procedure related complications and total duration of hospital stay were lower in transradial as compared to transfemoral group. Conclusion The number of percutaneous transradial procedures have increased significantly with reduced complication rates and comparable success rate to transfemoral approach, along with the additional benefits to patient in terms of patient comfort, preference and reduced cost of health delivery. PMID:23992998
Gostin, Lawrence O.
2001-01-01
Public health law reform is necessary because existing statutes are outdated, contain multiple layers of regulation, and are inconsistent. A model law would define the mission and functions of public health agencies, provide a full range of flexible powers, specify clear criteria and procedures for activities, and provide protections for privacy and against discrimination. The law reform process provides an opportunity for public health agencies to draw attention to their resource needs and achievements and to form ties with constituency groups and enduring relations with the legislative branch of government. Ultimately, the law should become a catalyst, rather than an impediment, to reinvigorating the public health system. PMID:11527757
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sather, Nichole K.; Borde, Amy B.; Diefenderfer, Heida L.
This Handbook of Data Reduction Procedures, Workbooks, and Exchange Templates is designed to support the Oncor geodatabase for the Columbia Estuary Ecosystem Restoration Program (CEERP). The following data categories are covered: water-surface elevation and temperature, sediment accretion rate, photo points, herbaceous wetland vegetation cover, tree plots and site summaries, fish catch and density, fish size, fish diet, fish prey, and Chinook salmon genetic stock identification. The handbook is intended for use by scientists collecting monitoring and research data for the CEERP. The ultimate goal of Oncor is to provide quality, easily accessible, geospatial data for synthesis and evaluation of themore » collective performance of CEERP ecosystem restoration actions at a program scale.« less
Maintaining and Monitoring the Defined Microbiota Status of Gnotobiotic Rodents.
Nicklas, Werner; Keubler, Lydia; Bleich, André
2015-01-01
Gnotobiotic (germfree, defined colonized) rodents have become powerful tools to advance our understanding of the host-microbiome relationship. However, the maintenance and ultimately the monitoring of gnotobiotic rodents is a critical, labor-intensive, and costly process (e.g., sterility, not absence of specific pathogens, must be demonstrated in germfree animals). Here, we provide information on the housing and maintenance of gnotobiotic animals, elucidate prophylactic measurements to avoid contamination, and make specific recommendations for sampling procedures, sampling frequencies, and test methods. © The Author 2015. Published by Oxford University Press on behalf of the Institute for Laboratory Animal Research. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Strategies to Mitigate a Mycobacterium marinum Outbreak in a Zebrafish Research Facility
Snell, Kathy; Mittge, Erika; Melancon, Ellie; Montgomery, Rebecca; McFadden, Marcie; Camoriano, Javier; Kent, Michael L.; Whipps, Christopher M.; Peirce, Judy
2016-01-01
Abstract In 2011, the zebrafish research facility at the University of Oregon experienced an outbreak of Mycobacterium marinum that affected both research fish and facility staff. A thorough review of risks to personnel, the zebrafish veterinary care program, and zebrafish husbandry procedures at the research facility followed. In the years since 2011, changes have been implemented throughout the research facility to protect the personnel, the fish colony, and ultimately the continued success of the zebrafish model research program. In this study, we present the history of the outbreak, the changes we implemented, and recommendations to mitigate pathogen outbreaks in zebrafish research facilities. PMID:27351618
Workshop on Moon in Transition: Apollo 14, KREEP, and Evolved Lunar Rocks
NASA Technical Reports Server (NTRS)
Taylor, G. J. (Editor); Warren, P. H. (Editor)
1989-01-01
Lunar rocks provide material for analyzing lunar history and now new evaluation procedures are available for discovering new information from the Fra Mauro highlands rocks, which are different from any other lunar samples. These and other topics were discussed at this workshop, including a new evaluation of the nature and history of KREEP, granite, and other evolved lunar rock types, and ultimately a fresh evaluation of the transition of the moon from its early anorthosite-forming period to its later stages of KREEPy, granitic, and mare magmatism. The summary of presentations and discussion is based on notes taken by the respective summarizers during the workshop.
Gostin, L O
2001-09-01
Public health law reform is necessary because existing statutes are outdated, contain multiple layers of regulation, and are inconsistent. A model law would define the mission and functions of public health agen cies, provide a full range of flexible powers, specify clear criteria and procedures for activities, and provide protections for privacy and against discrimination. The law reform process provides an opportunity for public health agencies to draw attention to their resource needs and achievements and to form ties with constituency groups and enduring relations with the legislative branch of government. Ultimately, the law should become a catalyst, rather than an impediment, to reinvigorating the public health system.
Domazet, Barbara; MacLennan, Gregory T.; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang
2008-01-01
The advent of new technologies has enabled deeper insight into processes atsubcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy. PMID:18787684
Domazet, Barbara; Maclennan, Gregory T; Lopez-Beltran, Antonio; Montironi, Rodolfo; Cheng, Liang
2008-03-15
The advent of new technologies has enabled deeper insight into processes at subcellular levels, which will ultimately improve diagnostic procedures and patient outcome. Thanks to cell enrichment methods, it is now possible to study cells in their native environment. This has greatly contributed to a rapid growth in several areas, such as gene expression analysis, proteomics, and metabolonomics. Laser capture microdissection (LCM) as a method of procuring subpopulations of cells under direct visual inspection is playing an important role in these areas. This review provides an overview of existing LCM technology and its downstream applications in genomics, proteomics, diagnostics and therapy.
Conducting pilot and feasibility studies.
Cope, Diane G
2015-03-01
Planning a well-designed research study can be tedious and laborious work. However, this process is critical and ultimately can produce valid, reliable study findings. Designing a large-scale randomized, controlled trial (RCT)-the gold standard in quantitative research-can be even more challenging. Even the most well-planned study potentially can result in issues with research procedures and design, such as recruitment, retention, or methodology. One strategy that may facilitate sound study design is the completion of a pilot or feasibility study prior to the initiation of a larger-scale trial. This article will discuss pilot and feasibility studies, their advantages and disadvantages, and implications for oncology nursing research. .
Green Synthesis of Iron Nanoparticles and Their Environmental Applications and Implications
Saif, Sadia; Tahir, Arifa; Chen, Yongsheng
2016-01-01
Recent advances in nanoscience and nanotechnology have also led to the development of novel nanomaterials, which ultimately increase potential health and environmental hazards. Interest in developing environmentally benign procedures for the synthesis of metallic nanoparticles has been increased. The purpose is to minimize the negative impacts of synthetic procedures, their accompanying chemicals and derivative compounds. The exploitation of different biomaterials for the synthesis of nanoparticles is considered a valuable approach in green nanotechnology. Biological resources such as bacteria, algae fungi and plants have been used for the production of low-cost, energy-efficient, and nontoxic environmental friendly metallic nanoparticles. This review provides an overview of various reports of green synthesised zero valent metallic iron (ZVMI) and iron oxide (Fe2O3/Fe3O4) nanoparticles (NPs) and highlights their substantial applications in environmental pollution control. This review also summarizes the ecotoxicological impacts of green synthesised iron nanoparticles opposed to non-green synthesised iron nanoparticles. PMID:28335338
Xie, Yunxuan; Qiu, Ning; Wang, Guangyi
2017-05-15
Prosperous development in marine-based tourism has raised increasing concerns over the sanitary quality of coastal waters with potential microbial contamination. The World Health Organization has set stringent standards over a list of pathogenic microorganisms posing potential threats to people with frequent coastal water exposure and has asked for efficient detection procedures for pathogen facile identification. Inspection of survey events regarding the occurrence of marine pathogens in recreational beaches in recent years has reinforced the need for the development of a rapid identification procedure. In this review, we examine the possibility of recruiting uniform molecular assays to identify different marine pathogens and the feasibility of appropriate biomarkers, including enterochelin biosynthetic genes, for general toxicity assays. The focus is not only on bacterial pathogens but also on other groups of infectious pathogens. The ultimate goal is the development of a handy method to more efficiently and rapidly detect marine pathogens. Copyright © 2017 Elsevier Ltd. All rights reserved.
Metabolomic approach with LC-MS reveals significant effect of pressure on diver's plasma.
Ciborowski, Michal; Javier Rupérez, F; Martínez-Alcázar, Ma Paz; Angulo, Santiago; Radziwon, Piotr; Olszanski, Romuald; Kloczko, Janusz; Barbas, Coral
2010-08-06
Professional and recreational diving are growing activities in modern life. Diving has been associated with increased prevalence of stroke, hypertension, asthma, diabetes, or bone necrosis. We evaluated the effect of increased pressure equivalent to diving at 30 and 60 m for 30 min in two groups of divers using an untargeted approach with LC-MS fingerprinting of plasma. We found over 100 metabolites to be altered in plasma post exposure and after the corresponding decompression procedures. Among them, a group of lysophosphatidylcholines and lysophosphatidylethanolamines were increased, including lysoplasmalogen, a thrombosis promoter, together with changes in metabolic rate-associated molecules such as acylcarnitines and hemolysis-related compounds. Moreover, three metabolites that could be associated to bone degradation show different intensities between experimental groups. Ultimately, this nontargeted, short-term study opens the possibility of discovering markers of long-term effect of pressure that could be employed in routine health control of divers and could facilitate the development of safer decompression procedures.
Taleb, A; Kandilian, R; Touchard, R; Montalescot, V; Rinaldi, T; Taha, S; Takache, H; Marchal, L; Legrand, J; Pruvost, J
2016-10-01
Strain selection is one of the primary hurdles facing cost-effective microalgal biodiesel production. Indeed, the strain used affects both upstream and downstream biodiesel production processes. This study presents a screening procedure that considers the most significant criteria in microalgal biodiesel production including TAG production and wet extraction and recovery of TAGs. Fourteen freshwater and seawater strains were investigated. Large variation was observed between the strains in all the screening criteria. The overall screening procedure ultimately led to the identification of Parachlorella kessleri UTEX2229 and Nannochloropsis gaditana CCMP527 as the best freshwater and seawater strains, respectively. They featured the largest areal TAG productivity equal to 2.7×10(-3) and 2.3×10(-3)kgm(-2)d(-1), respectively. These two strains also displayed encouraging cell fragility in a high pressure bead milling process with 69% and 98% cell disruption at 1750bar making them remarkable strains for TAG extraction in wet environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Corman, M L; Gravié, J-F; Hager, T; Loudon, M A; Mascagni, D; Nyström, P-O; Seow-Choen, F; Abcarian, H; Marcello, P; Weiss, E; Longo, A
2003-07-01
An international working party with experience in the performance of an alternative haemorrhoid operation through the use of the circular stapler was convened for the purpose of developing a consensus as to the criteria for undertaking this procedure. The agenda consisted of first, naming the operation; second, the indications and contra-indications for its performance; and third, the preferred surgical technique. Among the recommendations for individuals who plan to embark on this surgery are that experience with anorectal surgery and an understanding of anorectal anatomy are requisites; experience with circular stapling devices is essential; and the surgeon must attend a formal course which should include lectures, videos, the application of the instrument in models, and observation of the operation as performed by a surgeon recognized by his or her peers-leading ultimately to undertaking the procedure while being observed by an experienced surgeon. Following satisfactory completion of the above, independent responsibility should be determined by an individual's department of surgery.
Chen, Zhenfeng; Ge, Shuzhi Sam; Zhang, Yun; Li, Yanan
2014-11-01
This paper presents adaptive neural tracking control for a class of uncertain multiinput-multioutput (MIMO) nonlinear systems in block-triangular form. All subsystems within these MIMO nonlinear systems are of completely nonaffine pure-feedback form and allowed to have different orders. To deal with the nonaffine appearance of the control variables, the mean value theorem is employed to transform the systems into a block-triangular strict-feedback form with control coefficients being couplings among various inputs and outputs. A systematic procedure is proposed for the design of a new singularity-free adaptive neural tracking control strategy. Such a design procedure can remove the couplings among subsystems and hence avoids the possible circular control construction problem. As a consequence, all the signals in the closed-loop system are guaranteed to be semiglobally uniformly ultimately bounded. Moreover, the outputs of the systems are ensured to converge to a small neighborhood of the desired trajectories. Simulation studies verify the theoretical findings revealed in this paper.
Auditory event perception: the source-perception loop for posture in human gait.
Pastore, Richard E; Flint, Jesse D; Gaston, Jeremy R; Solomon, Matthew J
2008-01-01
There is a small but growing literature on the perception of natural acoustic events, but few attempts have been made to investigate complex sounds not systematically controlled within a laboratory setting. The present study investigates listeners' ability to make judgments about the posture (upright-stooped) of the walker who generated acoustic stimuli contrasted on each trial. We use a comprehensive three-stage approach to event perception, in which we develop a solid understanding of the source event and its sound properties, as well as the relationships between these two event stages. Developing this understanding helps both to identify the limitations of common statistical procedures and to develop effective new procedures for investigating not only the two information stages above, but also the decision strategies employed by listeners in making source judgments from sound. The result is a comprehensive, ultimately logical, but not necessarily expected picture of both the source-sound-perception loop and the utility of alternative research tools.
Campbell-Yeo, Marsha; Fernandes, Ananda; Johnston, Celeste
2011-10-01
This is the second of a 2-part series to provide an overview of our current level of knowledge related to nonpharmacological strategies to diminish the pain associated with commonly performed procedures in the NICU. In our first article we discussed the prevalence of repeated pain exposure in the NICU and the importance of nonpharmacological strategies specifically containment or facilitated tucking, swaddling, positioning, nonnutritive sucking, and sweet solutions. These strategies are generally nurse-driven and we believe their importance has been underutilized. In this article we will emphasize the importance of maternal presence as a mediator for pain relief. The efficacy of breastfeeding, maternal skin-to-skin care (often referred to as kangaroo care), and multisensorial stimulation such as auditory and olfactory recognition will be the primary focus of our discussion. In addition, although primarily mother-driven, these strategies are ultimately nurse-enabled, thus the importance of this connection cannot be under appreciated with respect to successful implementation in the NICU.
NASA Astrophysics Data System (ADS)
O'Shaughnessy, Richard; Lange, Jacob; Healy, James; Carlos, Lousto; Shoemaker, Deirdre; Lovelace, Geoffrey; Scheel, Mark
2016-03-01
In this talk, we apply a procedure to reconstruct the parameters of sufficiently massive coalescing compact binaries via direct comparison with numerical relativity simulations. We illustrate how to use only comparisons between synthetic data and these simulations to reconstruct properties of a synthetic candidate source. We demonstrate using selected examples that we can reconstruct posterior distributions obtained by other Bayesian methods with our sparse grid. We describe how followup simulations can corroborate and improve our understanding of a candidate signal.