Sample records for ultra-high-pressure liquid chromatography

  1. Ultra-high-pressure liquid chromatography-tandem mass spectrometry method for the determination of alkylphenols in soil.

    PubMed

    Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei

    2009-03-20

    A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.

  2. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    PubMed

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    PubMed

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Simultaneous determination of four alkaloids in Lindera aggregata by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang

    2008-11-28

    A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.

  5. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    PubMed

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Liquid chromatography-mass spectrometry in metabolomics research: mass analyzers in ultra high pressure liquid chromatography coupling.

    PubMed

    Forcisi, Sara; Moritz, Franco; Kanawati, Basem; Tziotis, Dimitrios; Lehmann, Rainer; Schmitt-Kopplin, Philippe

    2013-05-31

    The present review gives an introduction into the concept of metabolomics and provides an overview of the analytical tools applied in non-targeted metabolomics with a focus on liquid chromatography (LC). LC is a powerful analytical tool in the study of complex sample matrices. A further development and configuration employing Ultra-High Pressure Liquid Chromatography (UHPLC) is optimized to provide the largest known liquid chromatographic resolution and peak capacity. Reasonably UHPLC plays an important role in separation and consequent metabolite identification of complex molecular mixtures such as bio-fluids. The most sensitive detectors for these purposes are mass spectrometers. Almost any mass analyzer can be optimized to identify and quantify small pre-defined sets of targets; however, the number of analytes in metabolomics is far greater. Optimized protocols for quantification of large sets of targets may be rendered inapplicable. Results on small target set analyses on different sample matrices are easily comparable with each other. In non-targeted metabolomics there is almost no analytical method which is applicable to all different matrices due to limitations pertaining to mass analyzers and chromatographic tools. The specifications of the most important interfaces and mass analyzers are discussed. We additionally provide an exemplary application in order to demonstrate the level of complexity which remains intractable up to date. The potential of coupling a high field Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (ICR-FT/MS), the mass analyzer with the largest known mass resolving power, to UHPLC is given with an example of one human pre-treated plasma sample. This experimental example illustrates one way of overcoming the necessity of faster scanning rates in the coupling with UHPLC. The experiment enabled the extraction of thousands of features (analytical signals). A small subset of this compositional space could be mapped into a mass

  7. A simple dual online ultra-high pressure liquid chromatography system (sDO-UHPLC) for high throughput proteome analysis.

    PubMed

    Lee, Hangyeore; Mun, Dong-Gi; Bae, Jingi; Kim, Hokeun; Oh, Se Yeon; Park, Young Soo; Lee, Jae-Hyuk; Lee, Sang-Won

    2015-08-21

    We report a new and simple design of a fully automated dual-online ultra-high pressure liquid chromatography system. The system employs only two nano-volume switching valves (a two-position four port valve and a two-position ten port valve) that direct solvent flows from two binary nano-pumps for parallel operation of two analytical columns and two solid phase extraction (SPE) columns. Despite the simple design, the sDO-UHPLC offers many advantageous features that include high duty cycle, back flushing sample injection for fast and narrow zone sample injection, online desalting, high separation resolution and high intra/inter-column reproducibility. This system was applied to analyze proteome samples not only in high throughput deep proteome profiling experiments but also in high throughput MRM experiments.

  8. The use of ultra-high pressure liquid chromatography with tandem mass spectrometric detection of analysis of agrochemical residues and mycotoxines in food - challenges and applications

    USDA-ARS?s Scientific Manuscript database

    In the field of food contaminant analysis, the most significant development of recent years has been the integration of ultra-high pressure liquid chromatography (UHPLC), coupled to tandem quadrupole mass spectrometry (MS/MS), into analytical applications. In this review, we describe the emergence o...

  9. Coupling ultra high-pressure liquid chromatography with mass spectrometry: constraints and possible applications.

    PubMed

    Rodriguez-Aller, Marta; Gurny, Robert; Veuthey, Jean-Luc; Guillarme, Davy

    2013-05-31

    The introduction of columns packed with porous sub-2μm particles and the extension of the upper pressure limit of HPLC instrumentation to 1300bar (ultra-high pressure liquid chromatography, UHPLC) has opened new frontiers in resolution and speed of analysis. However, certain constraints appear when coupling UHPLC technology with mass spectrometry (MS). First, the most significant limitation is related to the narrow peaks that are produced by UHPLC that require a fast duty cycle, which is only available on the latest generations of MS devices. Thus, certain analyzers are more readily compatible with UHPLC (e.g., QqQ or TOF/MS) than others (e.g., ion trap or FT-MS). Second, due to the reduction of the column volume, extra-column band broadening can become significant, leading to a reduction in the kinetic performance of the UHPLC-MS configuration. Third, as the mobile phase linear velocity is higher in UHPLC, the electrospray ionization source must also be able to provide high sensitivity at flow rates of up to 1mL/min. Despite these limitations, the UHPLC-MS/MS platform has successfully been employed over the last decade for various types of applications, including those related to bioanalysis, drug metabolism, multi-residue screening, metabolomics, biopharmaceuticals and polar compounds. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  11. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  12. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  13. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  14. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  15. Rapid Catalyst Screening by a Continuous-Flow Microreactor Interfaced with Ultra High Pressure Liquid Chromatography

    PubMed Central

    Fang, Hui; Xiao, Qing; Wu, Fanghui; Floreancig, Paul E.; Weber, Stephen G.

    2010-01-01

    A high-throughput screening system for homogeneous catalyst discovery has been developed by integrating a continuous-flow capillary-based microreactor with ultra-high pressure liquid chromatography (UHPLC) for fast online analysis. Reactions are conducted in distinct and stable zones in a flow stream that allows for time and temperature regulation. UHPLC detection at high temperature allows high throughput online determination of substrate, product, and byproduct concentrations. We evaluated the efficacies of a series of soluble acid catalysts for an intramolecular Friedel-Crafts addition into an acyliminium ion intermediate within one day and with minimal material investment. The effects of catalyst loading, reaction time, and reaction temperature were also screened. This system exhibited high reproducibility for high-throughput catalyst screening and allowed several acid catalysts for the reaction to be identified. Major side products from the reactions were determined through off-line mass spectrometric detection. Er(OTf)3, the catalyst that showed optimal efficiency in the screening, was shown to be effective at promoting the cyclization reaction on a preparative scale. PMID:20666502

  16. Effect of extra-column volume on practical chromatographic parameters of sub-2-μm particle-packed columns in ultra-high pressure liquid chromatography.

    PubMed

    Wu, Naijun; Bradley, Ashley C; Welch, Christopher J; Zhang, Li

    2012-08-01

    Effects of extra-column volume on apparent separation parameters were studied in ultra-high pressure liquid chromatography with columns and inlet connection tubings of various internal diameters (id) using 50-mm long columns packed with 1.8-μm particles under isocratic conditions. The results showed that apparent retention factors were on average 5, 11, 18, and 41% lower than those corrected with extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns, respectively, when the extra-column volume (11.3 μL) was kept constant. Also, apparent pressures were 31, 16, 12, and 10% higher than those corrected with pressures from extra-column volumes for 4.6-, 3.0-, 2.1-, and 1.0-mm id columns at the respective optimum flow rate for a typical ultra-high pressure liquid chromatography system. The loss in apparent efficiency increased dramatically from 4.6- to 3.0- to 2.1- to 1.0-mm id columns, less significantly as retention factors increased. The column efficiency was significantly improved as the inlet tubing id was decreased for a given column. The results suggest that maximum ratio of extra-column volume to column void volume should be approximately 1:10 for column porosity more than 0.6 and a retention factor more than 5, where 80% or higher of theoretically predicted efficiency could be achieved. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. II: Confirmatory analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2010-06-18

    For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Multidetection of antibiotics in liver tissue by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry.

    PubMed

    Freitas, Andreia; Barbosa, Jorge; Ramos, Fernando

    2015-01-22

    A multiresidue quantitative screening method covering 39 antibiotics from 7 different families by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry (UHPLC-MS/MS) is described. Sulfonamides, trimethoprim, tetracyclines, macrolides, quinolones, penicillins and chloramphenicol are simultaneously detected in liver tissue. A simple sample treatment method consisting of extraction with a mixture of acetonitrile and ethylenediaminetetraacetic acid (EDTA) followed by solid-phase extraction (SPE) with a hydrophilic-lipophilic balanced (HLB) cartridge was developed. The methodology was validated, in accordance with Decision 2002/657/EC, by evaluating the following required parameters: decision limit (CCα), detection capability (CCβ), specificity, repeatability and reproducibility. The precision, in terms of the relative standard deviation, was under 22% for all of the compounds, and the recoveries were between 80% and 110%. The CCα and CCβ were determined according to the maximum residue limit (MRL) or the minimum required performance limit (MRPL), when established. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Lipid Identification by Untargeted Tandem Mass Spectrometry Coupled with Ultra-High-Pressure Liquid Chromatography.

    PubMed

    Gugiu, Gabriel B

    2017-01-01

    Lipidomics refers to the large-scale study of lipids in biological systems (Wenk, Nat Rev Drug Discov 4(7):594-610, 2005; Rolim et al., Gene 554(2):131-139, 2015). From a mass spectrometric point of view, by lipidomics we understand targeted or untargeted mass spectrometric analysis of lipids using either liquid chromatography (LC) (Castro-Perez et al., J Proteome Res 9(5):2377-2389, 2010) or shotgun (Han and Gross, Mass Spectrom Rev 24(3):367-412, 2005) approaches coupled with tandem mass spectrometry. This chapter describes the former methodology, which is becoming rapidly the preferred method for lipid identification owing to similarities with established omics workflows, such as proteomics (Washburn et al., Nat Biotechnol 19(3):242-247, 2001) or genomics (Yadav, J Biomol Tech: JBT 18(5):277, 2007). The workflow described consists in lipid extraction using a modified Bligh and Dyer method (Bligh and Dyer, Can J Biochem Physiol 37(8):911-917, 1959), ultra high pressure liquid chromatography fractionation of lipid samples on a reverse phase C18 column, followed by tandem mass spectrometric analysis and in silico database search for lipid identification based on MSMS spectrum matching (Kind et al., Nat Methods 10(8):755-758, 2013; Yamada et al., J Chromatogr A 1292:211-218, 2013; Taguchi and Ishikawa, J Chromatogr A 1217(25):4229-4239, 2010; Peake et al., Thermoscientifices 1-3, 2015) and accurate mass of parent ion (Sud et al., Nucleic Acids Res 35(database issue):D527-D532, 2007; Wishart et al., Nucleic Acids Res 35(database):D521-D526, 2007).

  20. Use of high pressure liquid chromatography in the study of liquid lubricant oxidation

    NASA Technical Reports Server (NTRS)

    Morales, W.

    1982-01-01

    The general principles of classical liquid chromatography and high-pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analysis of a C-ether liquid lubricant by each technique is illustrated. An analysis by size exclusion chromatography of an ester lubricant, which had been degraded using a micro-oxidation apparatus, is illustrated to show how HPLC can be used in the study of high-temperature lubricant degradation.

  1. Fast and sensitive analysis of beta blockers by ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry.

    PubMed

    Tomková, Jana; Ondra, Peter; Kocianová, Eva; Václavík, Jan

    2017-07-01

    This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Tunnel frit: a nonmetallic in-capillary frit for nanoflow ultra high-performance liquid chromatography-mass spectrometryapplications.

    PubMed

    Chen, Chao-Jung; Chen, Wei-Yun; Tseng, Mei-Chun; Chen, Yet-Ran

    2012-01-03

    In this study, an easy method to fabricate a durable in-capillary frit was developed for use in nanoflow liquid chromatography (nanoLC). A small orifice was tunneled into the sol-gel frit during the polymerization process resulting in the simple fabrication of a tunnel frit. A short packing tunnel frit column (2 cm, C(18) particles) was able to sustain over 10,000 psi continuous liquid flow for 10 days without observation of particle loss, and back pressure variation was less than 5%. The tunnel frit was successfully applied to the fabrication of nanoflow ultra high-performance liquid chromatography (nano-UHPLC) trap and analytical columns. In the analysis of tryptic peptides, the tunnel frit trap and analytical columns were demonstrated to have high separation efficiency and sensitivity. In analysis of phosphopeptides, the use of the nonmetallic tunnel frit column showed better sensitivity than the metallic frit column. This design can facilitate the preparation of nano-HPLC and nano-UHPLC columns and the packing material can easily be refilled when the column is severely contaminated or clogged. © 2011 American Chemical Society

  3. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    PubMed

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    USDA-ARS?s Scientific Manuscript database

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  5. Highly efficient and ultra-small volume separation by pressure-driven liquid chromatography in extended nanochannels.

    PubMed

    Ishibashi, Ryo; Mawatari, Kazuma; Kitamori, Takehiko

    2012-04-23

    The rapidly developing interest in nanofluidic analysis, which is used to examine liquids ranging in amounts from the attoliter to the femtoliter scale, correlates with the recent interest in decreased sample amounts, such as in the field of single-cell analysis. For general nanofluidic analysis, the fact that a pressure-driven flow does not limit the choice of solvents (aqueous or organic) is important. This study shows the first pressure-driven liquid chromatography technique that enables separation of atto- to femtoliter sample volumes, with a high separation efficiency within a few seconds. The apparent diffusion coefficient measurement of the unretentive sample suggests that there is no increase in the viscosity of toluene in the extended nanospace, unlike in aqueous solvents. Evaluation of the normal phase separation, therefore, should involve only the examination of the effect of the small size of the extended nanospace. Compared to a conventionally packed high-performance liquid chromatography column, the separation here results in a faster separation (4 s) by 2 orders of magnitude, a smaller injection volume (10(0) fL) by 9 orders, and a higher separation efficiency (440,000 plates/m) by 1 order. Moreover, the separation behavior agrees with the theory showing that this high efficiency was due to the small and controlled size of the separation channel, where the diffusion through the channel depth direction is fast enough to be neglected. Our chip-based platform should allow direct and real-time analysis or screening of ultralow volume of sample. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Fast log P determination by ultra-high-pressure liquid chromatography coupled with UV and mass spectrometry detections.

    PubMed

    Henchoz, Yveline; Guillarme, Davy; Martel, Sophie; Rudaz, Serge; Veuthey, Jean-Luc; Carrupt, Pierre-Alain

    2009-08-01

    Ultra-high-pressure liquid chromatography (UHPLC) systems able to work with columns packed with sub-2 microm particles offer very fast methods to determine the lipophilicity of new chemical entities. The careful development of the most suitable experimental conditions presented here will help medicinal chemists for high-throughput screening (HTS) log P(oct) measurements. The approach was optimized using a well-balanced set of 38 model compounds and a series of 28 basic compounds such as beta-blockers, local anesthetics, piperazines, clonidine, and derivatives. Different organic modifiers and hybrid stationary phases packed with 1.7-microm particles were evaluated in isocratic as well as gradient modes, and the advantages and limitations of tested conditions pointed out. The UHPLC approach offered a significant enhancement over the classical HPLC methods, by a factor 50 in the lipophilicity determination throughput. The hyphenation of UHPLC with MS detection allowed a further increase in the throughput. Data and results reported herein prove that the UHPLC-MS method can represent a progress in the HTS-measurement of lipophilicity due to its speed (at least a factor of 500 with respect to HPLC approaches) and to an extended field of application.

  7. Profiling of nonvolatiles in whiskeys using ultra high pressure liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS).

    PubMed

    Collins, Thomas S; Zweigenbaum, Jerry; Ebeler, Susan E

    2014-11-15

    Commercial samples of 63 American whiskeys, including bourbon whiskeys, Tennessee whiskeys, rye whiskeys and other blended whiskeys were analysed using ultra high pressure liquid chromatography (UHPLC) coupled with quadrupole time-of-flight (QTOF) mass spectrometry (MS). The non-volatile composition of the whiskeys was used to model differences among the samples using discriminant analysis. The blended American whiskeys were readily distinguished from the remaining types. Additionally, most Tennessee whiskeys could be differentiated from bourbon and rye whiskeys. Similarly, younger (<4 years old) and older (>8 years old) whiskeys could be separated. The compounds important for differentiating among these whiskeys included wood derived phenolic compounds, lignan derived compounds and several C8 and larger lipids. A number of additional compounds differentiated the whiskeys but could not be identified using MS and MS/MS data alone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. High temperature-ultra performance liquid chromatography-mass spectrometry for the metabonomic analysis of Zucker rat urine.

    PubMed

    Gika, Helen G; Theodoridis, Georgios; Extance, Jon; Edge, Anthony M; Wilson, Ian D

    2008-08-15

    The applicability and potential of using elevated temperatures and sub 2-microm porous particles in chromatography for metabonomics/metabolomics was investigated using, for the first time, solvent temperatures higher than the boiling point of water (up to 180 degrees C) and thermal gradients to reduce the use of organic solvents. Ultra performance liquid chromatography, combined with mass spectrometry, was investigated for the global metabolite profiling of the plasma and urine of normal and Zucker (fa/fa) obese rats (a well established disease animal model). "Isobaric" high temperature chromatography, where the temperature and flow rate follow a gradient program, was developed and evaluated against a conventional organic solvent gradient. LC-MS data were first examined by established chromatographic criteria in order to evaluate the chromatographic performance and next were treated by special peak picking algorithms to allow the application of multivariate statistics. These studies showed that, for urine (but not plasma), chromatography at elevated temperatures provided better results than conventional reversed-phase LC with higher peak capacity and better peak asymmetry. From a systems biology point of view, better group clustering and separation was obtained with a larger number of variables of high importance when using high temperature-ultra performance liquid chromatography (HT-UPLC) compared to conventional solvent gradients.

  9. Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces.

    PubMed

    Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi

    2017-08-04

    A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Synthesis of monodisperse silica microspheres and modification with diazoresin for mixed-mode ultra high performance liquid chromatography separations.

    PubMed

    Cong, Hailin; Yu, Bing; Tian, Chao; Zhang, Shuai; Yuan, Hua

    2017-11-01

    Monodisperse silica particles with average diameters of 1.9-2.9 μm were synthesized by a modified Stöber method, in which tetraethyl orthosilicate was continuously supplied to the reaction mixture containing KCl electrolyte, water, ethanol, and ammonia. The obtained silica particles were modified by self-assembly with positively charged photosensitive diazoresin on the surface. After treatment with ultraviolet light, the ionic bonding between silica and diazoresin was converted into covalent bonding through a unique photochemistry reaction of diazoresin. Depending on the chemical structure of diazoresin and mobile phase composition, the diazoresin-modified silica stationary phase showed different separation mechanisms, including reversed phase and hydrophilic interactions. Therefore, a variety of baseline separation of benzene analogues and organic acids was achieved by using the diazoresin-modified silica particles as packing materials in ultra high performance liquid chromatography. According to the π-π interactional difference between carbon rings of fullerenes and benzene rings of diazoresin, C 60 and C 70 were also well separated by ultra-high performance liquid chromatography. Because it has a small size, the ∼2.5 μm monodisperse diazoresin-modified silica stationary phase shows ultra-high efficiency compared with the commercial C 18 -silica high-performance liquid chromatography stationary phase with average diameters of ∼5 μm. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins.

    PubMed

    Gosselin, R C; Carlin, A C; Dwyre, D M

    2011-04-01

    Hemoglobin variants are a result of genetic changes resulting in abnormal or dys-synchronous hemoglobin chain production (thalassemia) or the generation of hemoglobin chain variants such as hemoglobin S. Automated high-pressure liquid chromatography (HPLC) systems have become the method of choice for the evaluation of patients suspected with hemoglobinopathies. In this study, we evaluated the performance of two HPLC methods used in the detection of common hemoglobin variants: Variant and Ultra2. There were 377 samples tested, 26% (99/377) with HbS, 8.5% (32/377) with HbC, 20.7% (78/377) with other hemoglobin variant or thalassemia, and 2.9% with increased hemoglobin A(1) c. The interpretations of each chromatograph were compared. There were no differences noted for hemoglobins A(0), S, or C. There were significant differences between HPLC methods for hemoglobins F, A(2), and A(1) c. However, there was good concordance between normal and abnormal interpretations (97.9% and 96.2%, respectively). Both Variant and Ultra2 HPLC methods were able to detect most common hemoglobin variants. There was better discrimination for fast hemoglobins, between hemoglobins E and A(2), and between hemoglobins S and F using the Ultra2 HPLC method. © 2010 Blackwell Publishing Ltd.

  12. Analysis of new psychoactive substances in human urine by ultra-high performance supercritical fluid and liquid chromatography: Validation and comparison.

    PubMed

    Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel

    2018-05-01

    New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. A rapid method for the simultaneous determination of 25 anti-hypertensive compounds in dietary supplements using ultra-high-pressure liquid chromatography.

    PubMed

    Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Park, Sung-Kwan; Baek, Sun Young

    2016-11-01

    A novel, stable, simple and specific ultra-performance liquid chromatography method with ultraviolet detection (205 nm) for the simultaneous analysis of 25 anti-hypertensive substances was developed. The method was validated according to the International Conference of Harmonisation guidelines with respect to linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ) and stability. From the ultra-performance liquid chromatography results, we identified the LOD and LOQ of solid samples to be 0.20-1.00 and 0.60-3.00 μg ml -1 , respectively, while those of liquid samples were 0.30-1.20 and 0.90-3.60 μg ml -1 , respectively. The linearity exceeded 0.9999, and the intra- and inter-day precisions were 0.15-6.48% and 0.28-8.67%, respectively. The intra- and inter-day accuracies were 82.25-111.42% and 80.70-115.64%, respectively, and the stability was lower than 12.9% (relative standard deviation). This method was applied to the monitoring of 97 commercially available dietary supplements obtained in Korea, such as pills, soft capsules, hard capsules, liquids, powders and tablets. The proposed method is accurate, precise and of high quality, and can be used for the routine, reproducible analysis and control of 25 anti-hypertensive substances in various dietary supplements. The work presented herein may help to prevent incidents related to food adulteration and restrict the illegal food market.

  14. Ultra-high-pressure liquid chromatography-tandem mass spectrometry for the analysis of six resorcylic acid lactones in bovine milk.

    PubMed

    Xia, Xi; Li, Xiaowei; Ding, Shuangyang; Zhang, Suxia; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong

    2009-03-20

    This work reports a rapid, reliable and sensitive multi-residue method for the simultaneous determination of six resorcylic acid lactones in bovine milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The resorcylic acid lactones were extracted, purified, and concentrated from milk samples in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric mixed-mode anion-exchange sorbent. The analysis was performed on a Waters Acquity BEH C(18) column utilizing a gradient elution profile. Each LC run was completed in 3.5 min. The analytes were detected by multiple reaction monitoring (MRM) using electrospray ionization (ESI) negative mode. Mean recoveries from fortified samples ranged from 92.6% to 112.5%, with relative standard deviations lower than 11.4%. Using 5 mL bovine milk, the limits of detection and quantification for resorcylic acid lactones were in the ranges of 0.01-0.05 and 0.05-0.2 microg/L, respectively. The application of this newly developed method was demonstrated by analyzing bovine milk samples from markets.

  15. An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates.

    PubMed

    Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G

    2017-03-15

    The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Isolation of Xanthomegnin from Penicillium viridicatum by Preparative High-Pressure Liquid Chromatography

    PubMed Central

    Peterson, R. E.; Grove, M. D.

    1983-01-01

    A method was developed for the production and purification of xanthomegnin from Penicillium viridicatum (NRRL 6430) cultured on rice at 15°C for 29 days. Liquid-liquid extraction followed by high-pressure liquid chromatography afforded 440 mg of crystalline xanthomegnin per kg of rice. PMID:6881966

  17. A practical approach for predicting retention time shifts due to pressure and temperature gradients in ultra-high-pressure liquid chromatography.

    PubMed

    Åsberg, Dennis; Chutkowski, Marcin; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2017-01-06

    Large pressure gradients are generated in ultra-high-pressure liquid chromatography (UHPLC) using sub-2μm particles causing significant temperature gradients over the column due to viscous heating. These pressure and temperature gradients affect retention and ultimately result in important selectivity shifts. In this study, we developed an approach for predicting the retention time shifts due to these gradients. The approach is presented as a step-by-step procedure and it is based on empirical linear relationships describing how retention varies as a function of temperature and pressure and how the average column temperature increases with the flow rate. It requires only four experiments on standard equipment, is based on straightforward calculations, and is therefore easy to use in method development. The approach was rigorously validated against experimental data obtained with a quality control method for the active pharmaceutical ingredient omeprazole. The accuracy of retention time predictions was very good with relative errors always less than 1% and in many cases around 0.5% (n=32). Selectivity shifts observed between omeprazole and the related impurities when changing the flow rate could also be accurately predicted resulting in good estimates of the resolution between critical peak pairs. The approximations which the presented approach are based on were all justified. The retention factor as a function of pressure and temperature was studied in an experimental design while the temperature distribution in the column was obtained by solving the fundamental heat and mass balance equations for the different experimental conditions. We strongly believe that this approach is sufficiently accurate and experimentally feasible for this separation to be a valuable tool when developing a UHPLC method. After further validation with other separation systems, it could become a useful approach in UHPLC method development, especially in the pharmaceutical industry where

  18. Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins.

    PubMed

    Zhu, Ling-Ling; Zhao, Yang; Xu, Yong-Wei; Sun, Qing-Long; Sun, Xin-Guang; Kang, Li-Ping; Yan, Ren-Yi; Zhang, Jie; Liu, Chao; Ma, Bai-Ping

    2016-02-20

    Spirostanol saponins are important active components of some herb medicines, and their isolation and purification are crucial for the research and development of traditional Chinese medicines. We aimed to compare the separation of spirostanol saponins by ultra-high performance supercritical fluid chromatography (UHPSFC) and ultra-high performance liquid chromatography (UHPLC). Four groups of spirostanol saponins were separated respectively by UHPSFC and UHPLC. After optimization, UHPSFC was performed with a HSS C18 SB column or a Diol column and with methanol as the co-solvent. A BEH C18 column and mobile phase containing water (with 0.1% formic acid) and acetonitrile were used in UHPLC. We found that UHPSFC could be performed automatically and quickly. It is effective in separating the spirostanol saponins which share the same aglycone and vary in sugar chains, and is very sensitive to the number and the position of hydroxyl groups in aglycones. However, the resolution of spirostanol saponins with different aglycones and the same sugar moiety by UHPSFC was not ideal and could be resolved by UHPLC instead. UHPLC is good at differentiating the variation in aglycones, and is influenced by double bonds in aglycones. Therefore, UHPLC and UHPSFC are complementary in separating spirostanol saponins. Considering the naturally produced spirostanol saponins in herb medicines are different both in aglycones and in sugar chains, a better separation can be achieved by combination of UHPLC and UHPSFC. UHPSFC is a powerful technique for improving the resolution when UHPLC cannot resolve a mixture of spirostanol saponins and vice versa. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Comparison of the response of four aerosol detectors used with ultra high pressure liquid chromatography.

    PubMed

    Hutchinson, Joseph P; Li, Jianfeng; Farrell, William; Groeber, Elizabeth; Szucs, Roman; Dicinoski, Greg; Haddad, Paul R

    2011-03-25

    The responses of four different types of aerosol detectors have been evaluated and compared to establish their potential use as a universal detector in conjunction with ultra high pressure liquid chromatography (UHPLC). Two charged-aerosol detectors, namely Corona CAD and Corona Ultra, and also two different types of light-scattering detectors (an evaporative light scattering detector, and a nano-quantity analyte detector [NQAD]) were evaluated. The responses of these detectors were systematically investigated under changing experimental and instrumental parameters, such as the mobile phase flow-rate, analyte concentration, mobile phase composition, nebulizer temperature, evaporator temperature, evaporator gas flow-rate and instrumental signal filtering after detection. It was found that these parameters exerted non-linear effects on the responses of the aerosol detectors and must therefore be considered when designing analytical separation conditions, particularly when gradient elution is performed. Identical reversed-phase gradient separations were compared on all four aerosol detectors and further compared with UV detection at 200 nm. The aerosol detectors were able to detect all 11 analytes in a test set comprising species having a variety of physicochemical properties, whilst UV detection was applicable only to those analytes containing chromophores. The reproducibility of the detector response for 11 analytes over 10 consecutive separations was found to be approximately 5% for the charged-aerosol detectors and approximately 11% for the light-scattering detectors. The tested analytes included semi-volatile species which exhibited a more variable response on the aerosol detectors. Peak efficiencies were generally better on the aerosol detectors in comparison to UV detection and particularly so for the light-scattering detectors which exhibited efficiencies of around 110,000 plates per metre. Limits of detection were calculated using different mobile phase

  20. High-pressure liquid chromatography with direct injection of gas sample.

    PubMed

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Rapid Characterization and Identification of Flavonoids in Radix Astragali by Ultra-High-Pressure Liquid Chromatography Coupled with Linear Ion Trap-Orbitrap Mass Spectrometry.

    PubMed

    Zhang, Jing; Xu, Xiao-Jie; Xu, Wen; Huang, Juan; Zhu, Da-yuan; Qiu, Xiao-Hui

    2015-07-01

    A simple and effective method was established for separation and characterization of flavonoid constituents in Radix Astragali (RA) by combination of ultra-high-pressure liquid chromatography with LTQ-Orbitrap tandem mass spectrometry (u-HPLC-LTQ-Orbitrap-MS(n)). For three major structural types of flavonoids, the proposed fragmentation pathways and major diagnostic fragment ions of isoflavones, pterocarpans and isoflavans were investigated to trace isoflavonoid derivatives in crude plant extracts. Based on the systematic identification strategy, 48 constituents were rapidly detected and characterized or tentatively identified, many of which were first reported in RA. The u-PHLC-LTQ-Orbitrap MS(n) platform was proved as an effective tool for rapid qualitative analysis of secondary metabolite productions from natural resources. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Qualitative Analysis of Analgesic Tablets: An Experiment Employing High Pressure Liquid Chromatography.

    ERIC Educational Resources Information Center

    Beaver, Rodney W.; And Others

    1983-01-01

    Describes an experiment on the qualitative analysis of several over-the-counter analgesic tablets. Background information, procedures used (including high pressure liquid chromatography), and typical student results are included. (JN)

  3. Study of the in vitro metabolism of TJ0711 using ultra high performance liquid chromatography with quadrupole time-of-flight and ultra fast liquid chromatography with quadrupole linear ion trap mass spectrometry.

    PubMed

    Hu, Lei; Lv, Zhenhua; Li, Gao; Xu, Xiaolong; Zhang, Chenghao; Cao, Peng; Huang, Jiangeng; Si, Luqin

    2015-06-01

    TJ0711 (1-[4-(2-methoxyethyl)phenoxy]-3-[2-(2-methoxyphenoxy)ethylamino]-2-propanol) is a novel β-adrenoreceptor blocker with vasodilating activity. The aim of this study was to investigate the in vitro metabolic properties of TJ0711 from both qualitative and quantitative aspects using mouse, rat, dog, and human liver microsomes as well as rat hepatocytes. Two modern liquid chromatography with tandem mass spectrometry systems, ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry and ultra fast liquid chromatography with quadrupole linear ion trap mass spectrometry, were utilized for the analysis. To better characterize the metabolic pathways of TJ0711, two major metabolites were incubated under the same conditions as that for TJ0711. TJ0711 was extensively metabolized in vitro, and a total of 34 metabolites, including 19 phase I and 15 phase II metabolites, were identified. Similar metabolite profiles were observed among species, and demethylation, hydroxylation, carboxylic acid formation, and glucuronidation were proposed as the major metabolic routes. Significant interspecies differences were observed in the metabolic stability studies of TJ0711. Furthermore, gender differences were significant in mice, rats, and dogs, but were negligible in humans. The valuable information provided in this work will be useful in planning and interpreting further pharmacokinetic, in vivo metabolism and toxicological studies of this novel β-blocker. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Rapid quantification of resveratrol in mouse plasma by ultra high pressure liquid chromatography (UPLC) coupled to tandem mass spectrometry.

    PubMed

    Castillo-Pichardo, Linette; Dharmawardhane, Suranganie; Rodríguez-Orengo, José F

    2014-12-01

    The objective of this study was to develop a rapid and sensitive method for the quantification of resveratrol, a polyphenolic compound with multiple health beneficial effects, in mouse plasma. We used reversed-phase ultra high pressure-liquid chromatography with tandem mass spectrometry detection for the determination of resveratrol levels in mouse plasma. An Agilent Zorbax Eclipse Plus C18 column (2.1 mm x 50 mm, 1.8 μm) was used as the stationary phase. The mobile phase consisted of a gradient formed using 1 mM ammonium fluoride and methanol. Using this improved method, we obtained a retention time of 2.2 min and a total run time of 5 min, for resveratrol. The calibration curve for resveratrol showed a linear range from 0.5 to 100 ng/mL. The average coefficient of variation was 6% for interday variation and 4% for intraday variation. The recovery for resveratrol in mouse plasma was 85 ± 10% (mean ± standard deviation). The method presented herein allows a rapid and very sensitive quantification of resveratrol in mouse plasma at concentrations as low as 500 ppt.

  5. Nontarget analysis of polar contaminants in freshwater sediments influenced by pharmaceutical industry using ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry.

    PubMed

    Terzic, Senka; Ahel, Marijan

    2011-02-01

    A comprehensive analytical procedure for a reliable identification of nontarget polar contaminants in aquatic sediments was developed, based on the application of ultra-high-pressure liquid chromatography (UHPLC) coupled to hybrid quadrupole time-of-flight mass spectrometry (QTOFMS). The procedure was applied for the analysis of freshwater sediment that was highly impacted by wastewater discharges from the pharmaceutical industry. A number of different contaminants were successfully identified owing to the high mass accuracy of the QTOFMS system, used in combination with high chromatographic resolution of UHPLC. The major compounds, identified in investigated sediment, included a series of polypropylene glycols (n=3-16), alkylbenzene sulfonate and benzalkonium surfactants as well as a number of various pharmaceuticals (chlorthalidone, warfarin, terbinafine, torsemide, zolpidem and macrolide antibiotics). The particular advantage of the applied technique is its capability to detect less known pharmaceutical intermediates and/or transformation products, which have not been previously reported in freshwater sediments. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-04-11

    The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in

  8. RECENT ADVANCES IN ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR THE ANALYSIS OF TRADITIONAL CHINESE MEDICINE

    PubMed Central

    Huang, Huilian; Liu, Min; Chen, Pei

    2014-01-01

    Traditional Chinese medicine has been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra-high performance liquid chromatography (UHPLC) is a relatively new technique offering new possibilities. This paper reviews recent developments in UHPLC in the separation and identification, fingerprinting, quantification, and metabolism of traditional Chinese medicine. Recently, the combination of UHPLC with MS has improved the efficiency of the analysis of these materials. PMID:25045170

  9. Application of ultra-high pressure liquid chromatography linear ion-trap orbitrap to qualitative and quantitative assessment of pesticide residues.

    PubMed

    Farré, M; Picó, Y; Barceló, D

    2014-02-07

    The analysis of pesticides residues using a last generation high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS) was explored. Pesticides were extracted from fruits, fish, bees and sediments by QuEChERS and from water by solid-phase with Oasis HLB cartridges. Ultra-high pressure liquid chromatography (UHPLC)-LTQ-Orbitrap mass spectrometer acquired full scan MS data for quantification, and data dependent (dd) MS(2) and MS(3) product ion spectra for identification and/or confirmation. The regression coefficients (r(2)) for the calibration curves (two order of magnitude up to the lowest calibration level) in the study were ≥0.99. The LODs for 54 validated compounds were ≤2ngmL(-1) (analytical standards). The relative standard deviation (RSD), which was used to estimate precision, was always lower than 22%. The recovery of extraction and matrix effects ranged from 58 to 120% and from -92 to 52%, respectively. Mass accuracy was always ≤4ppm, corresponding to a maximum mass error of 1.6millimass units (mmu). This procedure was then successfully applied to pesticide residues in a set of the above-mentioned food and environmental samples. In addition to target analytes, this method enables the simultaneous detection/identification of non-target pesticides, pharmaceuticals, drugs of abuse, mycotoxins, and their metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. A fully automated method for simultaneous determination of aflatoxins and ochratoxin A in dried fruits by pressurized liquid extraction and online solid-phase extraction cleanup coupled to ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Russo, Mariateresa; Valdés, Alberto; Ibáñez, Clara; Rastrelli, Luca

    2015-04-01

    According to current demands and future perspectives in food safety, this study reports a fast and fully automated analytical method for the simultaneous analysis of the mycotoxins with high toxicity and wide spread, aflatoxins (AFs) and ochratoxin A (OTA) in dried fruits, a high-risk foodstuff. The method is based on pressurized liquid extraction (PLE), with aqueous methanol (30%) at 110 °C, of the slurried dried fruit and online solid-phase extraction (online SPE) cleanup of the PLE extracts with a C18 cartridge. The purified sample was directly analysed by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for sensitive and selective determination of AFs and OTA. The proposed analytical procedure was validated for different dried fruits (vine fruit, fig and apricot), providing method detection and quantification limits much lower than the AFs and OTA maximum levels imposed by EU regulation in dried fruit for direct human consumption. Also, recoveries (83-103%) and repeatability (RSD < 8, n = 3) meet the performance criteria required by EU regulation for the determination of the levels of mycotoxins in foodstuffs. The main advantage of the proposed method is full automation of the whole analytical procedure that reduces the time and cost of the analysis, sample manipulation and solvent consumption, enabling high-throughput analysis and highly accurate and precise results.

  11. The effect of pressure and mobile phase velocity on the retention properties of small analytes and large biomolecules in ultra-high pressure liquid chromatography.

    PubMed

    Fekete, Szabolcs; Veuthey, Jean-Luc; McCalley, David V; Guillarme, Davy

    2012-12-28

    A possible complication of ultra-high pressure liquid chromatography (UHPLC) is related to the effect of pressure and mobile phase velocity on the retention properties of the analytes. In the present work, numerous model compounds have been selected including small molecules, peptides, and proteins (such as monoclonal antibodies). Two instrumental setups were considered to attain elevated pressure drops, firstly the use of a post-column restrictor capillary at low mobile phase flow rate (pure effect of pressure) and secondly the increase of mobile phase flow rate without restrictor (i.e. a combined effect of pressure and frictional heating). In both conditions, the goal was to assess differences in retention behaviour, depending on the type or character of the analyte. An important conclusion is that the effect of pressure and mobile phase velocity on retention varied in proportion with the size of the molecule and in some cases showed very different behaviour. In isocratic mode, the pure effect of pressure (experiments with a post-column restrictor capillary) induces an increase in retention by 25-100% on small molecules (MW<300 g/mol), 150% for peptides (~1.3 kDa), 800% for insulin (~6 kDa) and up to >3000% for myoglobin (~17 kDa) for an increase in pressure from 100 bar up to 1100 bar. The important effect observed for the isocratic elution of proteins is probably related to conformational changes of the protein in addition to the effect of molecular size. Working in gradient elution mode, the pressure related effects on retention were found to be less pronounced but still present (an increase of apparent retention factor between 0.2 and 2.5 was observed). Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Isolation of Gregatin A from Phialophora gregata by Preparative High-Pressure Liquid Chromatography

    PubMed Central

    Taylor, Scott L.; Peterson, Robert E.; Gray, Lynn E.

    1985-01-01

    A method was developed for the production and purification of gregatin A from Phialophora gregata NRRL 13198 cultured on rice at 20°C for 28 days. Liquid extraction followed by high-pressure liquid chromatography afforded 247.0 mg of crystalline gregatin A per kg of rice. PMID:16346936

  13. Ultra performance liquid chromatography atmospheric pressure photoionization high resolution mass spectrometric method for determination of multiclass pesticide residues in grape and mango juices.

    PubMed

    Deme, Pragney; Upadhyayula, Vijayasarathi V R

    2015-04-15

    A novel analytical method was developed for determination of organochlorine, synthetic pyrethroid, organophosphate and carbamate pesticide residues in fruit juices using ultra performance liquid chromatography-atmospheric pressure photoionization-high resolution mass spectrometry (UPLC-APPI-HRMS). The analytes were extracted from fruit juices by dispersive solid-phase extraction using multi-walled carbon nanotubes (MWCNTs). The analysis was carried out in full scan mode using dual ionization mode of APPI in the mass range of 100-650 units. The limit of detection and limit of quantification values for the pesticides were in the range of 0.025-0.15 ng mL(-1) and 0.1-0.5 ng mL(-1) respectively. The matrix effect of the method was found to be low and extraction recoveries were in the range of 60-110%. Some of the real fruits juice samples showed the presence of some pesticides in the range of 6.5-24.8 ng L(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Titanium-scaffolded organic-monolithic stationary phases for ultra-high-pressure liquid chromatography.

    PubMed

    Vonk, Rudy J; Vaast, Axel; Eeltink, Sebastiaan; Schoenmakers, Peter J

    2014-09-12

    Organic-polymer monoliths with overall dimensions larger than one millimetre are prone to rupture - either within the monolith itself or between the monoliths and the containing wall - due to the inevitable shrinkage accompanying the formation of a cross-linked polymeric network. This problem has been addressed by creating titanium-scaffolded poly(styrene-co-divinylbenzene) (S-co-DVB) monoliths. Titanium-scaffolded monoliths were successfully used in liquid chromatography at very high pressures (up to 80MPa) and using gradients spanning the full range of water-acetonitrile compositions (0 to 100%). The kinetic-performance of (50-mm long) titanium-scaffolded monoliths was compared to that of similar monolith created in 1-mm i.d. glass-lined tubing at pressures up to 50MPa. The peak capacities obtained with the titanium-scaffolded column was about 30% lower. An increased Eddy-diffusion, due to the pillar-structure, and a decreased permeability are thought to be the main reasons for this reduced kinetic-performance. No decrease in performance was observed when the titanium-scaffolded columns were operated at pressures of 80MPa for up to 12h. The column-to-column repeatability (n=5) was acceptable in terms of observed peak widths at half heights (RSD ca. 10%) The run-to-run repeatability (n=135) in terms of retention times and peak widths at half height were found to be good. Titanium-scaffolded columns coupled in series up to a combined length of (200mm) were used for the analyses of a complex Escherichia coli protein sample. Our experiments demonstrate that columns based on titanium-scaffolded organic-polymer monolith can be operated under strenuous conditions without loss in performance. The titanium-scaffolded approach makes it feasible to create organic-polymer monoliths in wide-bore columns with accurate temperature control. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Ultra-sensitive high performance liquid chromatography-laser-induced fluorescence based proteomics for clinical applications.

    PubMed

    Patil, Ajeetkumar; Bhat, Sujatha; Pai, Keerthilatha M; Rai, Lavanya; Kartha, V B; Chidangil, Santhosh

    2015-09-08

    An ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique has been developed by our group at Manipal, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from volunteers (normal, and different pre-malignant/malignant conditions) were recorded using this set-up. The protein profiles were analyzed using principal component analysis (PCA) to achieve objective detection and classification of malignant, premalignant and healthy conditions with high sensitivity and specificity. The HPLC-LIF protein profiling combined with PCA, as a routine method for screening, diagnosis, and staging of cervical cancer and oral cancer, is discussed in this paper. In recent years, proteomics techniques have advanced tremendously in life sciences and medical sciences for the detection and identification of proteins in body fluids, tissue homogenates and cellular samples to understand biochemical mechanisms leading to different diseases. Some of the methods include techniques like high performance liquid chromatography, 2D-gel electrophoresis, MALDI-TOF-MS, SELDI-TOF-MS, CE-MS and LC-MS techniques. We have developed an ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from healthy and volunteers with different malignant conditions were recorded by using this set-up. The protein profile data were analyzed using principal component analysis (PCA) for objective

  16. Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography

    ERIC Educational Resources Information Center

    Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.

    2004-01-01

    High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…

  17. Liquid-liquid phase separation causes high turbidity and pressure during low pH elution process in Protein A chromatography.

    PubMed

    Luo, Haibin; Lee, Nacole; Wang, Xiangyang; Li, Yuling; Schmelzer, Albert; Hunter, Alan K; Pabst, Timothy; Wang, William K

    2017-03-10

    Turbid elution pools and high column back pressure are common during elution of monoclonal antibodies (mAbs) by acidic pH in Protein A chromatography. This phenomenon has been historically attributed to acid-induced precipitation of incorrectly folded or pH-sensitive mAbs and host cell proteins (HCPs). In this work, we propose a new mechanism that may account for some observations of elution turbidity in Protein A chromatography. We report several examples of turbidity and high column back pressure occurring transiently under a short course of neutral conditions during Protein A elution. A systematic study of three mAbs displaying this behavior revealed phase separation characterized by liquid drops under certain conditions including neutral pH, low ionic strength, and high protein concentration. These liquid droplets caused solution turbidity and exhibited extremely high viscosity, resulting in high column back pressure. We found out that the droplets were formed through liquid-liquid phase separation (LLPS) as a result of protein self-association. We also found multiple factors, including pH, temperature, ionic strength, and protein concentration can affect LLPS behaviors. Careful selection of process parameters during protein A elution, including temperature, flow rate, buffer, and salt can inhibit formation of a dense liquid phase, reducing both turbidity (by 90%) and column back pressure (below 20 pounds per square inch). These findings provide both mechanistic insight and practical mitigation strategies for Protein A chromatography induced LLPS. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  18. High-pressure liquid chromatography analysis of antibiotic susceptibility disks.

    PubMed Central

    Hagel, R B; Waysek, E H; Cort, W M

    1979-01-01

    The analysis of antibiotic susceptibility disks by high-pressure liquid chromatography (HPLC) was investigated. Methods are presented for the potency determination of mecillinam, ampicillin, carbenicillin, and cephalothin alone and in various combinations. Good agreement between HPLC and microbiological data is observed for potency determinations with recoveries of greater than 95%. Relative standard deviations of lower than 2% are recorded for each HPLC method. HPLC methods offer improved accuracy and greater precision when compared to the standard microbiological methods of analysis for susceptibility disks. PMID:507793

  19. High-pressure liquid chromatography: A brief introduction and its application in analyzing the degradation of a C-ether (Thio-ether) liquid lubricant

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The general principles of classical liquid chromatography and high pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analytical separation of a C-ether liquid lubricant by each technique is illustrated. A practical application of HPLC is then demonstrated by analyzing a degraded C-ether liquid lubricant from full scale, high temperature bearing tests.

  20. Two-way and three-way approaches to ultra high performance liquid chromatography-photodiode array dataset for the quantitative resolution of a two-component mixture containing ciprofloxacin and ornidazole.

    PubMed

    Dinç, Erdal; Ertekin, Zehra Ceren; Büker, Eda

    2016-09-01

    Two-way and three-way calibration models were applied to ultra high performance liquid chromatography with photodiode array data with coeluted peaks in the same wavelength and time regions for the simultaneous quantitation of ciprofloxacin and ornidazole in tablets. The chromatographic data cube (tensor) was obtained by recording chromatographic spectra of the standard and sample solutions containing ciprofloxacin and ornidazole with sulfadiazine as an internal standard as a function of time and wavelength. Parallel factor analysis and trilinear partial least squares were used as three-way calibrations for the decomposition of the tensor, whereas three-way unfolded partial least squares was applied as a two-way calibration to the unfolded dataset obtained from the data array of ultra high performance liquid chromatography with photodiode array detection. The validity and ability of two-way and three-way analysis methods were tested by analyzing validation samples: synthetic mixture, interday and intraday samples, and standard addition samples. Results obtained from two-way and three-way calibrations were compared to those provided by traditional ultra high performance liquid chromatography. The proposed methods, parallel factor analysis, trilinear partial least squares, unfolded partial least squares, and traditional ultra high performance liquid chromatography were successfully applied to the quantitative estimation of the solid dosage form containing ciprofloxacin and ornidazole. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. High-throughput, Highly Sensitive Analyses of Bacterial Morphogenesis Using Ultra Performance Liquid Chromatography*

    PubMed Central

    Desmarais, Samantha M.; Tropini, Carolina; Miguel, Amanda; Cava, Felipe; Monds, Russell D.; de Pedro, Miguel A.; Huang, Kerwyn Casey

    2015-01-01

    The bacterial cell wall is a network of glycan strands cross-linked by short peptides (peptidoglycan); it is responsible for the mechanical integrity of the cell and shape determination. Liquid chromatography can be used to measure the abundance of the muropeptide subunits composing the cell wall. Characteristics such as the degree of cross-linking and average glycan strand length are known to vary across species. However, a systematic comparison among strains of a given species has yet to be undertaken, making it difficult to assess the origins of variability in peptidoglycan composition. We present a protocol for muropeptide analysis using ultra performance liquid chromatography (UPLC) and demonstrate that UPLC achieves resolution comparable with that of HPLC while requiring orders of magnitude less injection volume and a fraction of the elution time. We also developed a software platform to automate the identification and quantification of chromatographic peaks, which we demonstrate has improved accuracy relative to other software. This combined experimental and computational methodology revealed that peptidoglycan composition was approximately maintained across strains from three Gram-negative species despite taxonomical and morphological differences. Peptidoglycan composition and density were maintained after we systematically altered cell size in Escherichia coli using the antibiotic A22, indicating that cell shape is largely decoupled from the biochemistry of peptidoglycan synthesis. High-throughput, sensitive UPLC combined with our automated software for chromatographic analysis will accelerate the discovery of peptidoglycan composition and the molecular mechanisms of cell wall structure determination. PMID:26468288

  2. Sensitivity enhancement by chromatographic peak concentration with ultra-high performance liquid chromatography-nuclear magnetic resonance spectroscopy for minor impurity analysis.

    PubMed

    Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko

    2017-07-28

    High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Analytical interference of 4-hydroxy-3-methoxymethamphetamine with the measurement of plasma free normetanephrine by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Dunand, Marielle; Donzelli, Massimiliano; Rickli, Anna; Hysek, Cédric M; Liechti, Matthias E; Grouzmann, Eric

    2014-08-01

    The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. ANALYSIS OF SELECTED PYRETHROID PESTICIDES USING REVERSE PHASE HIGH PRESSURE LIQUID CHROMATOGRAPHY/UV

    EPA Science Inventory

    This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these py...

  5. Improved procedure for determination of flucytosine in human blood plasma by high-pressure liquid chromatography.

    PubMed Central

    Schwertschlag, U; Nakata, L M; Gal, J

    1984-01-01

    Several high-pressure liquid chromatography procedures for the determination of flucytosine in serum or plasma have appeared. Some of these suffer from significant disadvantages, and none was applicable in our routine clinical therapeutic-drug-monitoring laboratory. A new high-pressure liquid chromatography assay for flucytosine was therefore developed. A 100-microliter sample of plasma was treated with an aqueous 5-iodocytosine internal-standard solution, and the mixture was deproteinized with trichloroacetic acid. A portion of the protein-free supernatant was diluted with 0.1 M ammonium phosphate, and an aliquot of the resulting solution was injected into the high-pressure liquid chromatography system. Chromatography was performed on a strong-cation-exchange column with a mobile phase containing aqueous ammonium phosphate, phosphoric acid, methanol, and acetonitrile. Detection was at 254 nm. The assay was shown to be linear in the 10 to 200-micrograms/ml drug-concentration range. Forty other drugs were tested for potential interference with the assay, and none was found. For routine use, a single-point working standard containing 75 micrograms of flucytosine per ml was used, giving intraassay coefficients of variation at 50 and 150 micrograms/ml of 1.8 and 2.3% respectively, whereas the day-to-day coefficient of variation at 50 micrograms/ml was 10.0%. Advantages of the procedure include the small sample size, the use of a convenient and reliable internal standard, speed, and simplicity. The assay is highly suitable for routine clinical drug-analysis laboratories. PMID:6508261

  6. Negative-ion atmospheric pressure ionisation of semi-volatile fluorinated compounds for ultra-high-performance liquid chromatography tandem mass spectrometry analysis.

    PubMed

    Ayala-Cabrera, Juan F; Javier Santos, F; Moyano, Encarnación

    2018-05-24

    In this work, the feasibility of negative-ion atmospheric pressure chemical ionisation (APCI) and atmospheric pressure photoionisation (APPI) for ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) determination of fluorotelomer alcohols (FTOHs), fluorinated octanesulfonamides (FOSAs) and fluorinated octanesulfonamido-ethanols (FOSEs) was evaluated. The study of the effect of mobile phase composition on the atmospheric pressure ionisation of these compounds indicated that methanol/water mixtures provided the best responses in APCI, while acetonitrile/water with a post-column addition of toluene as dopant was the most appropriated mixture in APPI. Under the optimal working conditions, most of the target compounds produced the ion [M-H] - as base peak, although in-source collision-induced dissociation fragment ions in APCI and APPI and superoxide adduct ions [M+O 2 ] -• in APPI were also present. These ions proved to be more useful as precursor ions for MS/MS determination than the adduct ions generated in electrospray. Although the UHPLC-APCI-MS/MS method allowed the determination of these semi-volatile compounds at low concentration levels, the analysis by UHPLC-APPI-MS/MS provided the lowest limits of detection and it was applied to the analysis of water samples in combination with solid-phase extraction. Quality parameters demonstrated the good performance of the proposed method, providing low method limits of detection (0.3-6 ng L -1 ), good precision (RSD % < 5%) and an accurate quantification (relative error % < 14%). Among the river water samples analysed by the developed method, 4:2 FTOH and N-EtFOSA were determined at 30 and 780 ng L -1 , respectively.

  7. Peptide profiling of Internet-obtained Cerebrolysin using high performance liquid chromatography - electrospray ionization ion trap and ultra high performance liquid chromatography - ion mobility - quadrupole time of flight mass spectrometry.

    PubMed

    Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart

    2015-09-01

    Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Estimation of pressure-, temperature- and frictional heating-related effects on proteins' retention under ultra-high-pressure liquid chromatographic conditions.

    PubMed

    Fekete, Szabolcs; Guillarme, Davy

    2015-05-08

    The goal of this work was to evaluate the changes in retention induced by frictional heating, pressure and temperature under ultra high pressure liquid chromatography (UHPLC) conditions, for four model proteins (i.e. lysozyme, myoglobin, fligrastim and interferon alpha-2A) possessing molecular weights between 14 and 20kDa. First of all, because the decrease of the molar volume upon adsorption onto a hydrophobic surface was more pronounced for large molecules such as proteins, the impact of pressure appears to overcome the frictional heating effects. Nevertheless, we have also demonstrated that the retention decrease due to frictional heating was not negligible with such large biomolecules in the variable inlet pressure mode. Secondly, it is clearly shown that the modification of retention under various pressure and temperature conditions cannot be explained solely by the frictional heating and pressure effects. Indeed, some very uncommon van't Hoff plots (concave plots with a maximum) were recorded for our model/therapeutic proteins. These maximum retention factors values on the van't Hoff plots indicate a probable change of secondary structure/conformation with pressure and temperature. Based on these observations, it seems that the combination of pressure and temperature causes the protein denaturation and this folding-unfolding procedure is clearly protein dependent. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Neutral Fragment Filtering for Rapid Identification of New Diester-Diterpenoid Alkaloids in Roots of Aconitum carmichaeli by Ultra-High-Pressure Liquid Chromatography Coupled with Linear Ion Trap-Orbitrap Mass Spectrometry

    PubMed Central

    Qiu, Xiao Hui; Yang, Yi Ming; Zhu, Da Yuan; Xu, Wen

    2012-01-01

    A rapid and effective method was developed for separation and identification of diester-diterpenoid alkaloids (DDA) in the roots of Aconitum carmichaeli by ultra-high-pressure liquid chromatography coupled with high resolution LTQ-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MSn). According to accurate mass measurement and the characteristic neutral loss filtering strategy, a total of 42 diester-diterpenoid alkaloids (DDA) were rapidly detected and characterized or tentatively identified. Meanwhile, the proposed fragmentation pathways and the major diagnostic fragment ions of aconitine, mesaconitine and hypaconitine were investigated to trace DDA derivatives in crude plant extracts. 23 potential new compounds were successfully screened and characterized in Aconitum carmichaeli, including 16 short chain fatty acyls DDA, 4 N-dealkyl DDA and several isomers of aconitine, mesaconitine and hypaconitine. PMID:23285005

  10. Comprehensive quantitative analysis of Chinese patent drug YinHuang drop pill by ultra high-performance liquid chromatography quadrupole time of flight mass spectrometry.

    PubMed

    Wong, Tin-Long; An, Ya-Qi; Yan, Bing-Chao; Yue, Rui-Qi; Zhang, Tian-Bo; Ho, Hing-Man; Ren, Tian-Jing; Fung, Hau-Yee; Ma, Dik-Lung; Leung, Chung-Hang; Liu, Zhong-Liang; Pu, Jian-Xin; Han, Quan-Bin; Sun, Han-Dong

    2016-06-05

    YinHuang drop pill (YHDP) is a new preparation, derived from the traditional YinHuang (YH) decoction. Since drop pills are one of the newly developed forms of Chinese patent drugs, not much research has been done regarding the quality and efficacy. This study aims to establish a comprehensive quantitative analysis of the chemical profile of YHDP. ultra high-performance liquid chromatography quadrupole time of flight mass spectrometry (UHPLC-Q-TOF-MS/MS) was used to identify 34 non-sugar small molecules including 15 flavonoids, 9 phenolic acids, 5 saponins, 1 iridoid, and 4 iridoid glycosides in YHDP samples, and 26 of them were quantitatively determined. Sugar composition of YHDP in terms of fructose, glucose and sucrose was examined via a high performance liquid chromatography-evaporative light scattering detector on an amide column (HPLC-NH2P-ELSD). Macromolecules were examined by high performance gel permeation chromatography coupled with ELSD (HPGPC-ELSD). The content of the drop pill's skeleton component PEG-4000 was also quantified via ultra-high performance liquid chromatography coupled with charged aerosol detector (UHPLC-CAD). The results showed that up to 73% (w/w) of YHDP could be quantitatively determined. Small molecules accounted for approximately 5%, PEG-4000 represented 68%, while no sugars or macromolecules were found. Furthermore, YHDP showed no significant differences in terms of daily dosage, compared to YinHuang granules and YinHuang oral liquid; however, it has a higher small molecules content compared to YinHuang lozenge. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Effect of pressure on secondary structure of proteins under ultra high pressure liquid chromatographic conditions.

    PubMed

    Makarov, Alexey; LoBrutto, Rosario; Karpinski, Paul

    2013-11-29

    There are several spectroscopic techniques such as IR and CD, that allow for analyzing protein secondary structure in solution. However, a majority of these techniques require using purified protein, concentrated enough in the solution, to produce a relevant spectrum. Fundamental principles for the usage of reversed-phase ultra high pressure liquid chromatography (UHPLC) as an alternative technique to study protein secondary structures in solution were investigated. Several "model" proteins, as well as several small ionizable and neutral molecules, were used for these studies. The studies were conducted with UHPLC in isocratic mode, using premixed mobile phases at constant flow rate and temperature. The pressure was modified by a backpressure regulator from about 6000psi to about 12,000psi. It was found that when using a mobile phase composition at which proteins were fully denatured (loss of alpha-helix secondary structure), the retention factors of the proteins increased upon pressure increase in the same manner as non-proteins. When using a mobile phase composition in which proteins were not fully denatured, it was observed that the retention factors of the proteins displayed a much steeper (by one order of magnitude) increase in retention upon pressure increase. It was concluded that in a mobile phase in which the protein is not initially fully denatured, the increase of pressure may facilitate the folding back of the protein to its native state (alpha-helix secondary structure). The impact of different mobile phase compositions on the denaturation of the proteins was studied using CD (Circular Dichroism). Moreover, the effect of flow rate on retention of proteins and small molecules was studied at constant pressure on the different pore size silicas and the impact of internal frictional heating was evaluated. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Quantification of sulphur amino acids by ultra-high performance liquid chromatography in aquatic invertebrates.

    PubMed

    Thera, Jennifer C; Kidd, Karen A; Dodge-Lynch, M Elaine; Bertolo, Robert F

    2017-12-15

    We examined the performance of an ultra-high performance liquid chromatography method to quantify protein-bound sulphur amino acids in zooplankton. Both cysteic acid and methionine sulfone were linear from 5 to 250 pmol (r 2  = 0.99), with a method detection limit of 13 pmol and 9 pmol, respectively. Although there was no matrix effect on linearity, adjacent peaks and co-eluting noise from the invertebrate proteins increased the detection limits when compared to common standards. Overall, performance characteristics were reproducible and accurate, and provide a means for quantifying sulphur amino acids in aquatic invertebrates, an understudied group. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Quality evaluation of Semen Cassiae (Cassia obtusifolia L.) by using ultra-high performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Zhang, Wei-Dong; Wang, Ying; Wang, Qing; Yang, Wan-Jun; Gu, Yi; Wang, Rong; Song, Xiao-Mei; Wang, Xiao-Juan

    2012-08-01

    A sensitive and reliable ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry has been developed and partially validated to evaluate the quality of Semen Cassiae (Cassia obtusifolia L.) through simultaneous determination of 11 anthraquinones and two naphtha-γ-pyrone compounds. The analysis was achieved on a Poroshell 120 EC-C(18) column (100 mm × 2.1 mm, 2.7 μm; Agilent, Palo Alto, CA, USA) with gradient elution using a mobile phase that consisted of acetonitrile-water (30 mM ammonium acetate) at a flow rate of 0.4 mL/min. For quantitative analysis, all calibration curves showed perfect linear regression (r(2) > 0.99) within the testing range. This method was also validated with respect to precision and accuracy, and was successfully applied to quantify the 13 components in nine batches of Semen Cassiae samples from different areas. The performance of developed method was compared with that of conventional high-performance liquid chromatography method. The significant advantages of the former include high-speed chromatographic separation, four times faster than high-performance liquid chromatography with conventional columns, and great enhancement in sensitivity. This developed method provided a new basis for overall assessment on quality of Semen Cassiae. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Chemical profiling of bioactive constituents in Sarcandra glabra and its preparations using ultra-high-pressure liquid chromatography coupled with LTQ Orbitrap mass spectrometry.

    PubMed

    Li, Xiong; Zhang, Yufeng; Zeng, Xing; Yang, Liu; Deng, Yuanhui

    2011-09-15

    In this study, a fast and reliable method based on an ultra-high-pressure liquid chromatography coupled with photodiode-array detection (PDA) and a linear ion trap high-resolution mass spectrometer (LTQ-Orbitrap XL) has been developed for the identification of bioactive constituents in the whole plant of Sarcandra glabra and its related four preparations. By accurate mass measurements within 5 ppm error for each molecular ion and subsequent fragment ions in routine analysis, 50 compounds, including organic acids, caffeoyl derivatives, flavonoids, coumarins and terpenoids, were identified or tentatively characterized. Among them, 6,7,8-trihydroxycoumarin-O-rhamnopyranoside (17), (2R)-naringenin-6-C-B-D-glucopyranosyl-(6→1)-apiose (25) and (2S)-naringenin-6-C-B-D-glucopyranosyl-(6→1)-apiose (27) were tentatively identified as new compounds. Besides, 21 of these compounds were coexisting in four preparations of Sarcandra glabra. Fragmentation behaviors of the four major categories of compounds were also investigated. This established UPLC-PDA/ESI-MS(n) method was reliable and effective for the separation and identification of the major constituents and would be the basis for quality control of Sarcandra glabra and its related preparations. Copyright © 2011 John Wiley & Sons, Ltd.

  15. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    PubMed

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  16. Determination of ochratoxin A and T-2 toxin in alcoholic beverages by hollow fiber liquid phase microextraction and ultra high-pressure liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Romero-González, R; Frenich, A Garrido; Vidal, J L Martínez; Aguilera-Luiz, M M

    2010-06-30

    A new method for the determination of ochratoxin A and T-2 toxin in alcoholic beverages (wine and beer) by hollow fiber liquid microextraction was optimized. The extraction step was followed by ultra high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The extraction procedure was based on the extraction of mycotoxins from the sample to the organic solvent (1-octanol) immobilized in the fiber, and afterwards, they were desorbed in a mixture of acetonitrile/water (80:20, v/v) at pH 7 prior to chromatographic determination. Different variables affecting the extraction process such as organic solvent, salt content, extraction time and desorption solution were studied. The developed method was validated in wine and beer, using white wine and alcoholic beer as representative matrices for both types of samples. Relative recoveries higher than 70% were obtained for the selected mycotoxins. Good linearity (R(2)>0.993) was obtained and quantification limits (0.02-0.09 microg L(-1)) below European regulatory levels were achieved. Repeatability, expressed as relative standard deviation, was always lower than 12%, whereas interday precision was lower than 21%. The proposed method was applied to the analysis of several types of wines and beers and ochratoxin A was detected in a rosé wine at 1.1 microg L(-1). Copyright 2010 Elsevier B.V. All rights reserved.

  17. Simultaneous determination of phenolic compounds in Equisetum palustre L. by ultra high performance liquid chromatography with tandem mass spectrometry combined with matrix solid-phase dispersion extraction.

    PubMed

    Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie

    2014-11-01

    A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Enantioselective ultra high performance liquid and supercritical fluid chromatography: The race to the shortest chromatogram.

    PubMed

    Ciogli, Alessia; Ismail, Omar H; Mazzoccanti, Giulia; Villani, Claudio; Gasparrini, Francesco

    2018-03-01

    The ever-increasing need for enantiomerically pure chiral compounds has greatly expanded the number of enantioselective separation methods available for the precise and accurate measurements of the enantiomeric purity. The introduction of chiral stationary phases for liquid chromatography in the last decades has revolutionized the routine methods to determine enantiomeric purity of chiral drugs, agrochemicals, fragrances, and in general of organic and organometallic compounds. In recent years, additional efforts have been placed on faster, enantioselective analytical methods capable to fulfill the high throughput requirements of modern screening procedures. Efforts in this field, capitalizing on improved chromatographic particle technology and dedicated instrumentation, have led to highly efficient separations that are routinely completed on the seconds time scale. An overview of the recent achievements in the field of ultra-high-resolution chromatography on column packed with chiral stationary phases, both based on sub-2 μm fully porous and sub-3 μm superficially porous particles, will be given, with an emphasis on very recent studies on ultrafast chiral separations. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Reaction profiling by ultra high-pressure liquid chromatography/time-of-flight mass spectrometry in support of the synthesis of DNA-encoded libraries.

    PubMed

    Hargiss, Leonard O; Zipp, G Greg; Jessop, Theodore C; Sun, Xuejun; Keyes, Philip; Rawlins, David B; Liang, Zhi; Park, Kum Joo; Gu, Huizhong

    2014-11-15

    An ultra high-pressure liquid chromatography/mass spectrometry (UHPLC/MS) separation and analysis method has been devised for open access analysis of synthetic reactions used in the production of DNA-encoded chemical libraries. The aqueous mobile phase is 100mM hexafluoroisopropanol and 8.6mM triethylamine; the organic mobile phase is methanol. The UHPLC separation uses a C18 OST column (50mm×2.1mm×1.7μm) at 60°C, with a flow rate of 0.6mL/min. Gradient concentration is from 10 to 40% B in 1.0min, increasing to 95% B at 1.2min. Cycle time was about 5min. This method provides a detection limit of a 20-mer oligonucleotide by mass spectrometry of better than 1pmol on-column. Linear UV response for 20-mer extends from 2 to 200pmol/μL in concentration, same-day relative average deviations are less than 5% and bias (observed minus expected) is less than 10%. Deconvoluted mass spectra are generated for components in the predicted mass range using a maximum entropy algorithm. Mass accuracy of deconvoluted spectra is typically 20ppm or better for isotopomers of oligonucleotides up to 7000Da. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. High-pressure liquid chromatography of aromatic amines

    NASA Technical Reports Server (NTRS)

    Young, P. R.

    1979-01-01

    Analysis made on commercially available liquid chromatograph demonstrates high-pressure liquid chromatographic conditions for separation of approximately 50 aromatic amines ranging from simple aniline derivatives to complex multiring di- and tri-amines.

  1. Rapid determination of quinolones in cosmetic products by ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Liu, Shao-Ying; Huang, Xi-Hui; Wang, Xiao-Fang; Jin, Quan; Zhu, Guo-Nian

    2014-05-01

    This study developed an improved analytical method for the simultaneous quantification of 13 quinolones in cosmetics by ultra high performance liquid chromatography combined with ESI triple quadrupole MS/MS under the multiple reaction monitoring mode. The analytes were extracted and purified by using an SPE cartridge. The limits of quantification ranged from 0.03 to 3.02 μg/kg. The precision for determining the quinolones was <19.39%. The proposed method was successfully developed for the determination of quinolones in real cosmetic samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Simultaneous determination of 13 carotenoids by a simple C18 column-based ultra-high-pressure liquid chromatography method for carotenoid profiling in the astaxanthin-accumulating Haematococcus pluvialis.

    PubMed

    Jin, Hui; Lao, Yong Min; Zhou, Jin; Zhang, Huai Jin; Cai, Zhong Hua

    2017-03-10

    A simple ultra-high-pressure liquid chromatography (UHPLC) method for rapidly and simultaneously identifying thirteen carotenoids in Haematococcus pluvialis was developed in this study. The method is capable of effectively separating two astaxanthin isomers, two ζ-carotene isomers, and three phytoene isomers on two simple C18 columns within 9 and 12min only by using methanol and acetonitrile, respectively. To our best knowledge, this is the rapidest method for these carotenoid isomers, currently. Using this method, carotenoid profiling in the astaxanthin-accumulating H. pluvialis under environmental stresses was successfully carried out. Results indicated that carotenoid biosynthesis was differentially perturbed by environmental stresses, indicating that this simple and rapid method is suitable to not only bacterial but also algal samples, with potential applications for a wide range of samples from plant to animal. Finally, possible reasons for the elution order of carotenoids were studied. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A Laboratory Experiment in Pharmaceutical Analysis: Analysis of Diazepam Tablets by High Pressure Liquid Chromatography

    ERIC Educational Resources Information Center

    Bailey, Leonard

    1978-01-01

    The experiment described was developed for the third-year course in inorganic and analytical pharmaceutical chemistry to provide students with "hands-on" experience with high pressure liquid chromatography. Assay procedures are given along with experimental parameters and student results. (LBH)

  4. Determination of organophosphate diesters in urine samples by a high-sensitivity method based on ultra high pressure liquid chromatography-triple quadrupole-mass spectrometry.

    PubMed

    Su, Guanyong; Letcher, Robert J; Yu, Hongxia

    2015-12-24

    Organophosphate (OP) diesters in urine samples have potential use as biomarkers of organism exposure to environmentally relevant OP triester precursors and in particular OP triester flame retardants. This present study developed a quantitatively sensitive ultra high pressure liquid chromatography (UHPLC-MS) based method for urine and the determination of OP diesters (i.e. diphenyl phosphate (DPHP), bis(2-chloroethyl) phosphate (BCEP), bis(2-chloroisopropyl) phosphate (BDCIPP), di-n-butyl phosphate (DNBP), di(2-ethylhexyl) phosphate (DEHP), bis(1-chloro-2-propyl) phosphate (BCIPP), and bis(2-butoxyethyl) phosphate (BBOEP)). Fortified with the 7 OP diesters, 1mL of human urine sample was cleaned up using weak anion exchange solid phase extraction and eluted with high ionic strength ammonium acetate buffer. Subsequently, 4 non-chlorinated OP diesters were directly determined using UHPLC-electrospray(-)-triple quadrupole-MS (UHPLC-ESI(-)-QqQ-MS), and UHPLC-ESI(+)-QqQ-MS was used for determination of 3 chlorinated OP diesters after methylation using diazomethane. Recovery efficiencies of OP diesters ranged from 88 to 160% at three spiking levels (0.4, 2 and 10ng/mL urine). Matrix effects (MEs) and method limits of quantification (MLOQs) were 15-134% and 0.10-0.32ng/mL urine, respectively. Concentrations of OP diesters in n=12 urine samples (from 4 Canadian residents, 2014) varied as follows, nd-<0.28 (DNBP), nd-1.29 (DPHP), nd-<0.28 (DEHP), <0.16-12.33 (BCEP), nd-1.17 (BCDIPP) and nd-0.68ng/mL (BCIPP). Copyright © 2015. Published by Elsevier B.V.

  5. Further investigations of the effect of pressure on retention in ultra-high-pressure liquid chromatography.

    PubMed

    Fallas, Morgane M; Neue, Uwe D; Hadley, Mark R; McCalley, David V

    2010-01-15

    In this study, we investigated further the large increases in retention with pressure that we observed previously in RP-LC especially for ionised solutes. These findings were initially confirmed on a conventional silica C(18) column, which gave extremely similar results to the hybrid C(18) phase originally used. Large increases in retention factor of approximately 50% for a pressure increase of 500 bar were also shown for high MW polar but neutral solutes. However, experiments with the same bases in ionised and non-ionised forms suggest that somewhat greater pressure-induced retention increases are found for ionised solutes. Retention increases with pressure were found to be considerably smaller for a C(1) column compared with a C(18) column; decreases in retention with increasing pressure were noted for ionised bases when using a bare silica column in the hydrophilic interaction chromatography (HILIC) mode. These observations are consistent with the partial loss of the solvation layer in RP-LC as the solute is forced into the hydrophobic environment of the stationary phase, and consequent reduction in the solute molar volume, while the water layer on the surface of a HILIC packing increases the hydration of a basic analyte. Finally, retention changes with pressure in RP-LC can also be observed at a mobile phase pH close to the solute pK(a), due to changes in pK(a) with pressure. However, this effect has no influence on the results of most of our studies. 2009 Elsevier B.V. All rights reserved.

  6. Determination of mycotoxins in different food commodities by ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry.

    PubMed

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2009-06-01

    A rapid multianalyte-multiclass method with little sample manipulation has been developed for the simultaneous determination of eleven mycotoxins in different food commodities by using ultra-high-pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC/MS/MS). Toxins were extracted from the samples with acetonitrile/water (80:20, v/v) 0.1% HCOOH and, after a two-fold dilution with water, directly injected into the system. Thanks to the fast high-resolution separation of UHPLC, the eleven mycotoxins were separated by gradient elution in only 4 min. The method has been validated in three food matrices (maize kernels, dry pasta (wheat), and eight-multicereal babyfood (wheat, maize, rice, oat, barley, rye, sorghum, millet)) at four different concentration levels. Satisfactory recoveries were obtained (70-110%) and precision (expressed as relative standard deviation) was typically below 15% with very few exceptions. Quantification of samples was carried out with matrix-matched standards calibration. The lowest concentration successfully validated in sample was as low as 0.5 microg/kg for aflatoxins and ochratoxin A in babyfood, and 20 microg/kg for the rest of the selected mycotoxins in all matrices tested. Deoxynivalenol could be only validated at 200 microg/kg, due the poor sensitivity for this mycotoxin analysis. With only two exceptions (HT-2 and deoxynivalenol), the limits of detection (LODs), estimated for a signal-to-noise ratio of 3 from the chromatograms of samples spiked at the lowest level validated, varied between 0.1 and 1 microg/kg in the three food matrices tested. The method was applied to the analysis of different kinds of samples. Positive findings were confirmed by acquiring two transitions (Q quantification, q confirmation) and evaluating the Q/q ratio. Copyright (c) 2009 John Wiley & Sons, Ltd.

  7. Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography--comparison of performance.

    PubMed

    Płocharz, Paweł; Klimek-Turek, Anna; Dzido, Tadeusz H

    2010-07-16

    Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 microm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones. 2010 Elsevier B.V. All rights reserved.

  8. Sample injector for high pressure liquid chromatography

    DOEpatents

    Paul, Phillip H.; Arnold, Don W.; Neyer, David W.

    2001-01-01

    Apparatus and method for driving a sample, having a well-defined volume, under pressure into a chromatography column. A conventional high pressure sampling valve is replaced by a sample injector composed of a pair of injector components connected in series to a common junction. The injector components are containers of porous dielectric material constructed so as to provide for electroosmotic flow of a sample into the junction. At an appropriate time, a pressure pulse from a high pressure source, that can be an electrokinetic pump, connected to the common junction, drives a portion of the sample, whose size is determined by the dead volume of the common junction, into the chromatographic column for subsequent separation and analysis. The apparatus can be fabricated on a substrate for microanalytical applications.

  9. Determination of bisphenol AF (BPAF) in tissues, serum, urine and feces of orally dosed rats by ultra-high-pressure liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Yang, Yunjia; Yin, Jie; Yang, Yi; Zhou, Naiyuan; Zhang, Jing; Shao, Bing; Wu, Yongning

    2012-07-15

    As a homologue of bisphenol A (BPA), there is concern about the potential reproductive and developmental toxicity of bisphenol AF (BPAF) based on in vitro tests. In this study, a simple and universal analytical method was developed for the determination of trace BPAF in various tissues and excreta of rats after they were orally dosed. The samples were hydrolyzed with glucuronidase/arylsulfatase followed by ultrasonic extraction with acetonitrile. The crude extract was purified with a mixed-mode anion exchange (Oasis MAX) solid-phase extraction (SPE) cartridge. Separation and quantification was then conducted by ultra-high-pressure liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in negative ionization mode. The recoveries at three fortification levels in different biological samples were from 71.0% to 102.3% with relative standard deviations no more than 13.2% (n=6). The quantification limits of the method were from 0.5 μg/kg to 3 μg/kg depending on the matrix. This method was successfully applied to the determination of BPAF in tissues, serum, urine and feces of orally dosed rats. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. [Rapid identification of micro-constituents in monoammonium glycyrrhizinate raw materials by high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry].

    PubMed

    Yang, Xue-Dong; Tang, Xu-Yan; Sang, Lin

    2012-11-01

    To establish a method for rapid identification of micro-constituents in monoammonium glycyrrhizinate by high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry. HPLC preparative chromatograph was adopted for determining the optimal method for high-pressure solid phase extraction under optimal conditions. 5C18-MS-II column (20.0 mm x 20.0 mm) was used as the extraction column, with 35% acetonitrile-acetic acid solution (pH 2. 20) as eluent at the speed of 16 mL x min(-1). The sample size was 0.5 mL, and the extraction cycle was 4.5 min. Then, extract liquid was analyzed by high performance liquid chromatography-mass spectrometry (HPLC-MS) after being concentrated by 100 times. Under the optimal condition of high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry, 10 components were rapidly identified from monoammonium glycyrrhizinate raw materials. Among them, the chemical structures of six micro-constituents were identified as 3-O-[beta-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-0-beta-D-apiopyranosylglycyrrhetic/3-O- [P-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-O-beta-D-arabinopyranosylglycyrrhetic, glycyrrhizic saponin F3, 22-hydroxyglycyrrhizin/18alpha-glycyrrhizic saponin G2, 3-O-[beta-D-rhamnopyranosyl]-24-hydroxyglycyrrhizin, glycyrrhizic saponin J2, and glycyrrhizic saponin B2 by MS(n) spectra analysis and reference to literatures. Four main chemical components were identified as glycyrrhizic saponin G2, 18beta-glycyrrhizic acid, uralglycyrrhizic saponin B and 18alpha-glycyrrhizic acid by liquid chromatography, MS(n) and ultraviolet spectra information and comparison with reference substances. The method can be used to identify chemical constituents in monoammonium glycyrrhizinate quickly and effectively, without any reference substance, which provides basis for quality control and safe application of monoammonium glycyrrhizinate-related products.

  11. Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples.

    PubMed

    Liang, Ning; Huang, Peiting; Hou, Xiaohong; Li, Zhen; Tao, Lei; Zhao, Longshan

    2016-02-01

    A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16% to 99.80% with relative standard deviations between 0.7 and 8.4%. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.

  12. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography.

    PubMed

    Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD < 3%), accuracy (100.68-102.69%), and robustness. The UHPLC-DAD/GC-MS method was successfully utilized to analyze volatile components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.

  13. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry I. Screening analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Avois, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2009-05-15

    The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.

  14. Fast analysis of 29 polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs with ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry

    PubMed Central

    Lung, Shih-Chun Candice; Liu, Chun-Hu

    2015-01-01

    Polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs are ubiquitous in the environment. Some of them are probable carcinogens and some are source markers. This work presents an ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UHPLC-APPI-MS/MS) method for simultaneous analysis of 20 PAHs and nine nitro-PAHs. These compounds are separated in 15 minutes in the positive mode and 11 minutes in the negative mode, one half of GC/MS analysis time. Two pairs of precursor/product ions are offered, which is essential for confirmation. This method separates and quantifies benzo[a]pyrene (the most toxic PAHs) and non-priority benzo[e]pyrene (isomers, little toxicity) to avoid overestimation of toxin levels, demonstrating its importance for health-related researches. With 0.5% 2,4-difluoroanisole in chlorobenzene as the dopant, limits of detection of PAHs except acenaphthylene and those of nitro-PAHs except 2-nitrofluoranthene are below 10 pg and 3 pg, respectively, mostly lower than or comparable to those reported using LC-related systems. The responses were linear over two orders of magnitude with fairly good accuracy and precision. Certified reference materials and real aerosol samples were analyzed to demonstrate its applicability. This fast, sensitive, and reliable method is the first UHPLC-APPI-MS/MS method capable of simultaneously analyzing 29 environmentally and toxicologically important PAHs and nitro-PAHs. PMID:26265155

  15. Rapid identification of Clostridium species by high-pressure liquid chromatography.

    PubMed Central

    Harpold, D J; Wasilauskas, B L; O'Connor, M L

    1985-01-01

    High-pressure liquid chromatography was evaluated as a rapid means of identifying various species of clostridia. Isolates were inoculated into a defined medium and incubated aerobically for 1 h at 35 degrees C. The organisms were removed, and the supernatants were derivatized for 1 min at room temperature by the addition of o-phthalaldehyde. The total time required to run each chromatogram was approximately 50 min. Standardized peak heights for each medium component and any new peaks formed were calculated for each isolate and compared with those for uninoculated control medium. Multiple isolates of various Clostridium species gave consistent patterns of medium utilization that could be used for identification. This rapid method can easily be adapted for laboratory use and has the potential for automation. PMID:3905852

  16. Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.

    PubMed

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.

  17. A dispersive liquid-liquid micellar microextraction for the determination of pharmaceutical compounds in wastewaters using ultra-high-performace liquid chromatography with DAD detection.

    PubMed

    Montesdeoca-Esponda, Sarah; Mahugo-Santana, Cristina; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan

    2015-03-01

    A dispersive liquid-liquid micellar microextraction (DLLMME) method coupled with ultra-high-performance liquid chromatography (UHPLC) using Diode Array Detector (DAD) detector was developed for the analysis of five pharmaceutical compounds of different nature in wastewaters. A micellar solution of a surfactant, polidocanol, as extraction solvent (100 μL) and chloroform as dispersive solvent (200 μL) were used to extract and preconcentrate the target analytes. Samples were heated above critical temperature and the cloudy solution was centrifuged. After removing the chloroform, the reduced volume of surfactant was then injected in the UHPLC system. In order to obtain high extraction efficiency, the parameters affecting the liquid-phase microextraction, such as time and temperature extraction, ionic strength and surfactant and organic solvent volume, were optimized using an experimental design. Under the optimized conditions, this procedure allows enrichment factors of up to 47-fold. The detection limit of the method ranged from 0.1 to 2.0 µg/L for the different pharmaceuticals. Relative standard deviations were <26% for all compounds. The procedure was applied to samples from final effluent collected from wastewater treatment plants in Las Palmas de Gran Canaria (Spain), and two compounds were measured at 67 and 113 µg/L in one of them. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Simultaneous determination of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi

    2016-02-01

    A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Preparative Isolation and Purification of Flavone C-Glycosides from the Leaves of Ficus microcarpa L. f by Medium-Pressure Liquid Chromatography, High-Speed Countercurrent Chromatography, and Preparative Liquid Chromatography

    PubMed Central

    Wang, Xiaohong; Liang, Yong; Zhu, Licai; Xie, Huichun; Li, Hang; He, Junting; Pan, Man; Zhang, Tianyou; Ito, Yoichiro

    2009-01-01

    Combined with medium-pressure liquid chromatography (MPLC) and preparative high-performance liquid chromatography (perp-HPLC), high-speed countercurrent chromatography (HSCCC) was applied for separation and purification of flavone C-glycosides from the crude extract of leaves of Ficus microcarpae L. f. HSCCC separation was performed on a two-phase solvent system composed of methyl tert- butyl ether - ethyl acetate – 1-butanol – acetonitrile – 0.1% aqueous trifluoroacetic acid at a volume ratio of 1:3:1:1:5. Partially resolved peak fractions from HSCCC separation were further purified by preparative HPLC. Four well-separated compounds were obtained and their purities were determined by HPLC. The purities of these peaks were 97.28%, 97.20%, 92.23%, and 98.40%.. These peaks were characterized by ESI-MSn. According to the reference, they were identified as orientin (peak I), isovitexin-3″-O-glucopyranoside (peak II), isovitexin (peak III), and vitexin (peak IV), yielded 1.2 mg, 4.5 mg, 3.3 mg, and 1.8 mg, respectively. PMID:20190866

  20. Salting-out assisted liquid-liquid extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of tetracycline residues in infant foods.

    PubMed

    Moreno-González, David; García-Campaña, Ana M

    2017-04-15

    The use of salting-out assisted liquid-liquid extraction (SALLE) combined with ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) has been evaluated for the determination of tetracyclines in infant foods based on meat and vegetables or in milk. To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized. Analytical performances of the method were satisfactory, obtaining limits of quantification lower than 0.48μgkg -1 in all cases. The precision, expressed as relative standard deviation (%, RSD) was below 11.3%. The extraction efficiency for fortified samples ranged from 89.2 to 96.8%, with RSDs lower than 7.3%. Matrix effect was evaluated for all samples studied, being lower than |21|% in all cases. In relation to the low solvent consumption, the proposed methodology could be considered rapid, cheap and environmentally friendly. Its applicability has been successfully tested in a wide range of infant foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Determination of Fusarium toxins in functional vegetable milks applying salting-out-assisted liquid-liquid extraction combined with ultra-high-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Hamed, Ahmed M; Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2017-11-01

    Vegetable milks are considered as functional foods due to their physiological benefits. Although the consumption of these products has significantly increased, they have received little attention in legislation with regard to contaminants. However, they may contain mycotoxins resulting from the use of contaminated raw materials. In this work, ultra-high-performance liquid chromatography tandem mass spectrometry has been proposed for the determination of the most relevant Fusarium toxins (fumonisin B 1 and B 2 , HT-2 and T-2 toxins, zearalenone, deoxynivalenol and fusarenon-X) in different functional beverages based on cereals, legumes and seeds. Sample treatment consisted of a simple salting-out-assisted liquid-liquid extraction with no further clean-up. The method provided limits of quantification between 3.2 and 57.7 µg L -1 , recoveries above 80% and precision with RSD lower than 12%. The method was also applied for studying the occurrence of these mycotoxins in market samples of vegetable functional beverages and deoxynivalenol was found in three oat-based commercial drinks.

  2. Ultra-high-pressure liquid chromatography tandem mass spectrometry determination of hallucinogenic drugs in hair of psychedelic plants and mushrooms consumers.

    PubMed

    Pichini, Simona; Marchei, Emilia; García-Algar, Oscar; Gomez, Arelis; Di Giovannandrea, Rita; Pacifici, Roberta

    2014-11-01

    A procedure based on ultra-high-pressure liquid chromatography tandem mass spectrometry has been developed for the determination of mescaline, N,N-dimethyltryptamine, psilocin, psilocybin, salvinorin A in hair of consumers of psychedelic vegetal material such peyote or trichocereus cacti, psilocybe mushrooms, Salvia divinorum or psychedelic beverage ayahuasca. After hair washing with methyl alcohol and diethyl ether and subsequent addition of mescaline-d9 and 3,4-methylenedioxypropylamphetamine as internal standards, hair samples were treated with 250μl VMA-T M3 reagent for 1h at 100°C. After cooling, 100μl M3 extract were diluted with 400μl water and a volume of 10μl was injected into chromatographic system. Chromatographic separation was achieved at ambient temperature using a reverse-phase column and a linear gradient elution with two solvents: 0.3% formic acid in acetonitrile and 5mM ammonium formate pH 3. The mass spectrometer was operated in positive ion mode, using multiple reaction monitoring via positive electrospray ionization. The method was linear from the limit of quantification (0.03-0.05ng/mg depending on analyte under investigation) to 10ng/mg hair, with an intra- and inter-assay imprecision and inaccuracy always less than 15% and an analytical recovery between 79.6% and 97.4%, depending on the considered analyte. Using the validated method, mescaline was found in concentration range of 0.08-0.13ng/mg in hair of peyote smokers, 3.2ng salvinorin A per mg hair were determined in hair from a S. divinorum smoker, 5.6ng N,N-dimethyltryptamine per mg hair from an ayahuasca user and finally 0.8ng psilocybin per ng hair of a psilocybe consumer. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Ultra-high-pressure liquid chromatography tandem mass spectrometry determination of antidepressant and anxiolytic drugs in neonatal meconium and maternal hair.

    PubMed

    Pichini, Simona; Cortes, Laura; Marchei, Emilia; Solimini, Renata; Pacifici, Roberta; Gomez-Roig, Mª Dolores; García-Algar, Oscar

    2016-01-25

    A procedure based on ultra-high-pressure liquid chromatography tandem mass spectrometry has been developed for the determination of 22 antidepressant and anxiolytic drugs ad metabolites in the three consecutive maternal hair segments representing the pregnancy trimesters and paired neonatal meconium samples. After hair washing with methyl alcohol and diethyl ether and subsequent addition of internal standards, hair samples were treated with 500 μl VMA-T M3 reagent for 1h at 100 °C. After cooling, 100 μl M3 extract were diluted with 400 μl water and a volume of 10 μl was injected into chromatographic system. Meconium samples were firstly treated with 1 ml methyl alcohol and the organic layer back-extracted twice with 1.5 ml of a mixture of ethylacetate:hexane (80:20, v/v). Chromatographic separation was achieved at ambient temperature using a reverse-phase column and a linear gradient elution with two solvents: 0.3% formic acid in acetonitrile and 5mM ammonium formate pH 3. The mass spectrometer was operated in positive ion mode, using multiple reaction monitoring via positive electrospray ionization. The method was linear from the limit of quantification (0.05-1 ng/mg hair and 5-25 ng/g meconium depending on analyte under investigation;) to 10 ng/mg hair and 1000 ng/g meconium, with an intra- and inter-assay imprecision and inaccuracy always less than 20% and an analytical recovery between 66.6% and 95.3%, depending on the considered analyte and biological matrix. Using the validated method, 7 mothers were found positive to one or more hair segments and 5 meconium samples were found positive to one or more antidepressant and anxiolytic drugs, assessing prenatal exposure to these drugs following maternal consumption in one or more pregnancy trimesters. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Metabolic Profile of Zearalenone in Liver Microsomes from Different Species and Its in Vivo Metabolism in Rats and Chickens Using Ultra High-Pressure Liquid Chromatography-Quadrupole/Time-of-Flight Mass Spectrometry.

    PubMed

    Yang, Shupeng; Zhang, Huiyan; Sun, Feifei; De Ruyck, Karl; Zhang, Jinzhen; Jin, Yue; Li, Yanshen; Wang, Zhanhui; Zhang, Suxia; De Saeger, Sarah; Zhou, Jinhui; Li, Yi; De Boevre, Marthe

    2017-12-27

    To explore differences of zearalenone (ZEN) metabolism between various species, phase I and II metabolism by liver microsomes of animals and human were investigated using ultra high-pressure liquid chromatography-quadrupole/time-of-flight mass spectrometry (UHPLC-Q/TOF MS). A total of 24 metabolites were identified, among which 12 were reported for the first time. Reduction, hydroxylation, and glucuronidation were the major metabolic pathways of ZEN, and significant differences in various species were also observed. Reduction was the main reaction in swine and human, whereas hydroxylation was predominant in rats, chickens, goats, and cows in in vitro systems. Furthemore, in vivo metabolism of ZEN in rats and chickens was investigated, and 23 and 6 metabolites were identified in each species, respectively. Reduction, hydroxylation, and glucuronidation were the major metabolic pathways in rats, while reduction and sulfation predominated in chickens. These results further enrich the biotransformation profile of ZEN, providing a helpful reference for assessing the risks to animals and humans.

  5. Systematic Analysis of Absorbed Anti-Inflammatory Constituents and Metabolites of Sarcandra glabra in Rat Plasma Using Ultra-High-Pressure Liquid Chromatography Coupled with Linear Trap Quadrupole Orbitrap Mass Spectrometry

    PubMed Central

    Li, Xiong; Zhao, Jin; Liu, Jianxing; Li, Geng; Zhao, Ya; Zeng, Xing

    2016-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) was coupled with linear ion trap quadrupole Orbitrap mass spectrometry (LTQ-Orbitrap) and was used for the first time to systematically analyze the absorbed components and metabolites in rat plasma after oral administration of the water extract of Sarcandra glabra. This extract is a well-known Chinese herbal medicine for the treatment of inflammation and immunity related diseases. The anti-inflammatory activities of the absorbed components were evaluated by measuring nitric oxide (NO) production and proinflammatory genes expression in lipopolysaccharide (LPS)-stimulated murine RAW 264.7 macrophages. As a result, 54 components in Sarcandra glabra were detected in dosed rat plasma, and 36 of them were positively identified. Moreover, 23 metabolites were characterized and their originations were traced. Furthermore, 20 of the 24 studied components showed anti-inflammatory activities. These results provide evidence that this method efficiency detected constituents in plasma based on the anti-inflammatory mechanism of multiple components and would be a useful technique for screening multiple targets for natural medicine research. PMID:26974321

  6. Systematic Analysis of Absorbed Anti-Inflammatory Constituents and Metabolites of Sarcandra glabra in Rat Plasma Using Ultra-High-Pressure Liquid Chromatography Coupled with Linear Trap Quadrupole Orbitrap Mass Spectrometry.

    PubMed

    Li, Xiong; Zhao, Jin; Liu, Jianxing; Li, Geng; Zhao, Ya; Zeng, Xing

    2016-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) was coupled with linear ion trap quadrupole Orbitrap mass spectrometry (LTQ-Orbitrap) and was used for the first time to systematically analyze the absorbed components and metabolites in rat plasma after oral administration of the water extract of Sarcandra glabra. This extract is a well-known Chinese herbal medicine for the treatment of inflammation and immunity related diseases. The anti-inflammatory activities of the absorbed components were evaluated by measuring nitric oxide (NO) production and proinflammatory genes expression in lipopolysaccharide (LPS)-stimulated murine RAW 264.7 macrophages. As a result, 54 components in Sarcandra glabra were detected in dosed rat plasma, and 36 of them were positively identified. Moreover, 23 metabolites were characterized and their originations were traced. Furthermore, 20 of the 24 studied components showed anti-inflammatory activities. These results provide evidence that this method efficiency detected constituents in plasma based on the anti-inflammatory mechanism of multiple components and would be a useful technique for screening multiple targets for natural medicine research.

  7. Optimized ultra-high-pressure-assisted extraction of procyanidins from lychee pericarp improves the antioxidant activity of extracts.

    PubMed

    Zhang, Ruifen; Su, Dongxiao; Hou, Fangli; Liu, Lei; Huang, Fei; Dong, Lihong; Deng, Yuanyuan; Zhang, Yan; Wei, Zhencheng; Zhang, Mingwei

    2017-08-01

    To establish optimal ultra-high-pressure (UHP)-assisted extraction conditions for procyanidins from lychee pericarp, a response surface analysis method with four factors and three levels was adopted. The optimum conditions were as follows: 295 MPa pressure, 13 min pressure holding time, 16.0 mL/g liquid-to-solid ratio, and 70% ethanol concentration. Compared with conventional ethanol extraction and ultrasonic-assisted extraction methods, the yields of the total procyanidins, flavonoids, and phenolics extracted using the UHP process were significantly increased; consequently, the oxygen radical absorbance capacity and cellular antioxidant activity of UHP-assisted lychee pericarp extracts were substantially enhanced. LC-MS/MS and high-performance liquid chromatography quantification results for individual phenolic compounds revealed that the yield of procyanidin compounds, including epicatechin, procyanidin A2, and procyanidin B2, from lychee pericarp could be significantly improved by the UHP-assisted extraction process. This UHP-assisted extraction process is thus a practical method for the extraction of procyanidins from lychee pericarp.

  8. Simultaneous quantification of antimicrobial agents for multidrug-resistant bacterial infections in human plasma by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Tsai, I-Lin; Sun, Hsin-Yun; Chen, Guan-Yuan; Lin, Shu-Wen; Kuo, Ching-Hua

    2013-11-15

    Antibiotic-resistant bacterial infection is one of the most serious clinical problems worldwide. Vancomycin, teicoplanin, daptomycin, and colistin are glycopeptide and lipopeptide antibiotics that are frequently used to treat multidrug-resistant bacterial infections. Therapeutic drug monitoring is recommended to ensure both safety and efficacy and to improve clinical outcomes. This study developed a fast, simple, and sensitive ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of the concentrations of these four drugs in human plasma. The sample preparation process includes a simple protein denaturation step using acetonitrile, followed by an 11-fold dilution with 0.1% formic acid. Eight target peaks for the four drugs can be analyzed within 3 min using a Kinetex™ 2.6 μm C18 column. The mass spectrometry parameters were optimized, and two transitions for each target peak were used for multiple reaction monitoring, which provided high sensitivity and specificity. The UHPLC-MS/MS method was validated over clinical concentration ranges. The intra-day and inter-day precisions for the ratio of the peak area of each analyte to the peak area of the internal standard were all below 12.7 and 14.7% relative standard deviations, respectively. The accuracy at low, medium, and high concentrations of the eight target peaks was between 89.3 and 110.7%. The standard curves for the analytes were linear and had coefficients of determination higher than 0.997. The limits of detection were all below 70 ng mL(-1). The use of this method to analyze patient plasma samples confirmed that it is effective for the therapeutic drug monitoring of these four drugs and can be used to improve the therapeutic efficacy and safety of treatment with antibiotics. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    PubMed

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Determination of acetaminophen concentrations in serum by high-pressure liquid chromatography.

    PubMed

    Horvitz, R A; Jatlow, P I

    1977-09-01

    We describe a method for determination of serum acetaminophen concentrations in serum by reversed phase high-pressure liquid chromatography. The homolog N-propionyl-p-aminophenol was used as an internal standard. The procedure, which requires only a single extraction with diethyl ether, can be optimized to be linear over the ranges of 10 to 100 or 1 to 20 mg/liter. Within-run CV was 1.2%; between-run CV was 4.4% and 4.9% at two different concentrations. Many commonly used drugs were tested and found not to interfere. The procedure is simple and rapid enough for use on an emergency basis in cases of overdosage, and can be optimized for measurement of either therapeutic or toxic concentrations.

  11. Bacterial Cell Wall Precursor Phosphatase Assays Using Thin-layer Chromatography (TLC) and High Pressure Liquid Chromatography (HPLC).

    PubMed

    Pazos, Manuel; Otten, Christian; Vollmer, Waldemar

    2018-03-20

    Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by 'attacking' enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius . The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II.

  12. Ultra pressure liquid chromatography-negative electrospray ionization mass spectrometry determination of twelve halobenzoquinones at ng/L levels in drinking water.

    PubMed

    Huang, Rongfu; Wang, Wei; Qian, Yichao; Boyd, Jessica M; Zhao, Yuli; Li, Xing-Fang

    2013-05-07

    We report here the characterization of twelve halobenzoquinones (HBQs) using electrospray ionization (ESI) high resolution quadrupole time-of-flight mass spectrometry. The high resolution negative ESI spectra of the twelve HBQs formed two parent ions, [M + H(+) + 2e(-)], and the radical M(-•). The intensities of these two parent ions are dependent on their chemical structures and on instrumental parameters such as the source temperature and flow rate. The characteristic ions of the HBQs were used to develop an ultra pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. At the UPLC flow rate (400 μL/min) and under the optimized ESI conditions, eleven HBQs showed the stable and abundant transitions [M + H(+) + 2e(-)] → X(-) (X(-) representing Cl(-), Br(-), or I(-)), while dibromo-dimethyl-benzoquinone (DBDMBQ) showed only the transition of M(-•) → Br(-). The UPLC efficiently separates all HBQs including some HBQ isomers, while the MS/MS offers exquisite limits of detection (LODs) at subng/mL levels for all HBQs except DBDMBQ. Combined with solid phase extraction (SPE), the method LOD is down to ng/L. The results from analysis of authentic samples demonstrated that the SPE-UPLC-MS/MS method is reliable, fast, and sensitive for the identification and quantification of the twelve HBQs in drinking water.

  13. A simple, rapid and novel method based on salting-out assisted liquid-liquid extraction for ochratoxin A determination in beer samples prior to ultra-high performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Mariño-Repizo, Leonardo; Goicoechea, Hector; Raba, Julio; Cerutti, Soledad

    2018-06-07

    A novel, simple, easy and cheap sample treatment strategy based on salting-out assisted liquid-liquid extraction (SALLE) for ochratoxin A (OTA) ultra-trace analysis in beer samples using ultra-high performance liquid chromatography-tandem mass spectrometry determination was developed. The factors involved in the efficiency of pretreatment were studied employing factorial design in the screening phase and the optimal conditions of the significant variables on the analytical response were evaluated using a central composite face-centred design (CCF). Consequently, the amount of salt ((NH 4 ) 2 SO 4 ), together with the volumes of sample, hydrophilic (acetone) and nonpolar (toluene) solvents, and times of vortexing and centrifugation were optimized. Under optimized conditions, the limits of detection (LOD) and quantification (LOQ) were 0.02 µg l -1 and 0.08 µg l -1 respectively. OTA extraction recovery by SALLE was approximately 90% (0.2 µg l -1 ). Furthermore, the methodology was in agreement with EU Directive requirements and was successfully applied for analysis of beer samples.

  14. Identification of absorbed constituents and in vivo metabolites in rats after oral administration of Physalis alkekengi var. franchetii by ultra-high-pressure liquid chromatography quadrupole time-of-flight mass spectrometry.

    PubMed

    Feng, Xinchi; Huo, Xiaoguang; Liu, Hongxia; Chai, Liwei; Ding, Liqin; Qiu, Feng

    2018-03-01

    The calyces of Physalis alkekengi var. franchetii (Chinese Lantern, JDL) are well-known as traditional Chinese medicine owing to its various therapeutic effects. However, the bioactive constituents responsible for the pharmacological effects of JDL and their metabolites in vivo are still unclear to date. In this paper, an ultra-high-pressure liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UHPLC/Q-TOF-MS/MS) method was established to identify absorbed constituents and in vivo metabolites in rat biological fluids after oral administration of JDL. Based on the proposed strategy, 33 compounds were observed in dosed rat biosamples. Twelve of 33 compounds were indicated as prototype components of JDL, and 21 compounds were predicted to be metabolites of JDL. Finally, the metabolic pathways were proposed, which were glucuronidation, sulfation, methylation and dehydroxylation for flavonoid constituents and sulfonation and hydroxylation for physalin consitituents. This is the first systematic study on the absorbed constituents and metabolic profiling of JDL and will provide a useful template for screening and characterizing the ingredients and metabolites of traditional Chinese medicine. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Characterization of polyoxyethylene tallow amine surfactants in technical mixtures and glyphosate formulations using ultra-high performance liquid chromatography and triple quadrupole mass spectrometry

    USGS Publications Warehouse

    Tush, Daniel; Loftin, Keith A.; Meyer, Michael T.

    2013-01-01

    Little is known about the occurrence, fate, and effects of the ancillary additives in pesticide formulations. Polyoxyethylene tallow amine (POEA) is a non-ionic surfactant used in many glyphosate formulations, a widely applied herbicide both in agricultural and urban environments. POEA has not been previously well characterized, but has been shown to be toxic to various aquatic organisms. Characterization of technical mixtures using ultra-high performance liquid chromatography (UHPLC) and mass spectrometry shows POEA is a complex combination of homologs of different aliphatic moieties and ranges of ethoxylate units. Tandem mass spectrometry experiments indicate that POEA homologs generate no product ions readily suitable for quantitative analysis due to poor sensitivity. A comparison of multiple high performance liquid chromatography (HPLC) and UHPLC analytical columns indicates that the stationary phase is more important in column selection than other parameters for the separation of POEA. Analysis of several agricultural and household glyphosate formulations confirms that POEA is a common ingredient but ethoxylate distributions among formulations vary.

  16. An ultra-high performance liquid chromatography method to determine the skin penetration of an octyl methoxycinnamate-loaded liquid crystalline system.

    PubMed

    Prado, A H; Borges, M C; Eloy, J O; Peccinini, R G; Chorilli, M

    2017-10-01

    Cutaneous penetration is a critical factor in the use of sunscreen, as the compounds should not reach systemic circulation in order to avoid the induction of toxicity. The evaluation of the skin penetration and permeation of the UVB filter octyl methoxycinnamate (OMC) is essential for the development of a successful sunscreen formulation. Liquid-crystalline systems are innovative and potential carriers of OMC, which possess several advantages, including controlled release and protection of the filter from degradation. In this study, a new and effective method was developed using ultra-high performance liquid chromatography (UPLC) with ultraviolet detection (UV) for the quantitative analysis of penetration of OMC-loaded liquid crystalline systems into the skin. The following parameters were assessed in the method: selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD), and limit of quantification (LOQ). The analytical curve was linear in the range from 0.25 to 250 μg.m-1, precise, with a standard deviation of 0.05-1.24%, with an accuracy in the range from 96.72 to 105.52%, and robust, with adequate values for the LOD and LOQ of 0.1 and 0.25 μg.mL -1, respectively. The method was successfully used to determine the in vitro skin permeation of OMC-loaded liquid crystalline systems. The results of the in vitro tests on Franz cells showed low cutaneous permeation and high retention of the OMC, particularly in the stratum corneum, owing to its high lipophilicity, which is desirable for a sunscreen formulation.

  17. Parallel ultra high pressure liquid chromatography-mass spectrometry for the quantification of HIV protease inhibitors using dried spot sample collection format.

    PubMed

    Watanabe, Kyoko; Varesio, Emmanuel; Hopfgartner, Gérard

    2014-08-15

    An assay was developed and validated for the quantification of eight protease inhibitors (indinavir (IDV), ritonavir (RTV), lopinavir (LPV), saquinavir (SQV), amprenavir (APV), nelfinavir (NFV), atazanavir (AZV) and darunavir (DRV)) in dried plasma spots using parallel ultra-high performance liquid chromatography and mass spectrometry detection in the multiple reaction monitoring mode. For each analyte an isotopically labeled internal standard was used and the assay based on liquid-solid extraction the area response ratio (analyte/IS) was found to be linear; from 0.025 μg/ml to 20 μg/ml for IDV, SQV, DRV, AZV, LPV, from 0.025 μg/ml to 10 μg/ml for NFV, APV and from 0.025 μg/ml to 5 μg/ml for RTV using 15 μl of plasma spotted on filter paper placed in a sample tube. The total analysis time was of 4 min and inter-assay accuracies and precisions were in the range of 87.7-109% and 2.5-11.8%, respectively. On dried plasma spots all analytes were found to be stable for at least 7 days. Practicability of the assay to blood was also demonstrated. The sample drying process could be reduced to 5 min using a commercial microwave system without any analyte degradation. Together with quantification, confirmatory analysis was performed on representative clinical samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Bacterial Cell Wall Precursor Phosphatase Assays Using Thin-layer Chromatography (TLC) and High Pressure Liquid Chromatography (HPLC)

    PubMed Central

    Pazos, Manuel; Otten, Christian; Vollmer, Waldemar

    2018-01-01

    Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by ‘attacking’ enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius. The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II. PMID:29651453

  19. Rapid separation and characterization of diterpenoid alkaloids in processed roots of Aconitum carmichaeli using ultra high performance liquid chromatography coupled with hybrid linear ion trap-Orbitrap tandem mass spectrometry.

    PubMed

    Xu, Wen; Zhang, Jing; Zhu, Dayuan; Huang, Juan; Huang, Zhihai; Bai, Junqi; Qiu, Xiaohui

    2014-10-01

    The lateral root of Aconitum carmichaeli, a popular traditional Chinese medicine, has been widely used to treat rheumatic diseases. For decades, diterpenoid alkaloids have dominated the phytochemical and biomedical research on this plant. In this study, a rapid and sensitive method based on ultra high performance liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry was developed to characterize the diterpenoid alkaloids in Aconitum carmichaeli. Based on an optimized chromatographic condition, more than 120 diterpenoid alkaloids were separated with good resolution. Using a systematic strategy that combines high resolution separation, highly accurate mass measurements and a good understanding of the diagnostic fragment-based fragmentation patterns, these diterpenoid alkaloids were identified or tentatively identified. The identification of these chemicals provided essential data for further phytochemical studies and toxicity research of Aconitum carmichaeli. Moreover, the ultra high performance liquid chromatography with linear ion trap-Orbitrap mass spectrometry platform was an effective and accurate tool for rapid qualitative analysis of secondary metabolite productions from natural resources. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A high pressure liquid chromatography method for separation of prolactin forms.

    PubMed

    Bell, Damon A; Hoad, Kirsten; Leong, Lillian; Bakar, Juwaini Abu; Sheehan, Paul; Vasikaran, Samuel D

    2012-05-01

    Prolactin has multiple forms and macroprolactin, which is thought not to be bioavailable, can cause a raised serum prolactin concentration. Gel filtration chromatography (GFC) is currently the gold standard method for separating macroprolactin, but is labour-intensive. Polyethylene glycol (PEG) precipitation is suitable for routine use but may not always be accurate. We developed a high pressure liquid chromatography (HPLC) assay for macroprolactin measurement. Chromatography was carried out using an Agilent Zorbax GF-250 (9.4 × 250 mm, 4 μm) size exclusion column and 50 mmol/L Tris buffer with 0.15 mmol/L NaCl at pH 7.2 as mobile phase, with a flow rate of 1 mL/min. Serum or plasma was diluted 1:1 with mobile phase and filtered and 100 μL injected. Fractions of 155 μL were collected for prolactin measurement and elution profile plotted. The area under the curve of each prolactin peak was calculated to quantify each prolactin form, and compared with GFC. Clear separation of monomeric-, big- and macroprolactin forms was achieved. Quantification was comparable to GFC and precision was acceptable. Total time from injection to collection of the final fraction was 16 min. We have developed an HPLC method for quantification of macroprolactin, which is rapid and easy to perform and therefore can be used for routine measurement.

  1. Isolation and purification of six iridoid glycosides from gardenia jasminoides fruit by medium-pressure liquid chromatography combined with macroporous resin chromatography.

    PubMed

    Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun

    2015-12-01

    Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Profiling the indole alkaloids in yohimbe bark with ultra-performance liquid chromatography coupled with ion mobility quadrupole time-of-flight mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    An ultra-high performance liquid chromatography-ion mobility- quadrupole time-of-flight mass spectrometry (UHPLC-IM-QTOF-MS) method was developed for profiling the indole alkaloids in yohimbe bark. Many indole alkaloids with the yohimbine core structure, plus methylated, oxidized, and reduced speci...

  3. Simultaneous and rapid determination of deoxynivalenol and its acetylate derivatives in wheat flour and rice by ultra high performance liquid chromatography with photo diode array detection.

    PubMed

    Xu, Jiao-Jiao; Zhou, Jian; Huang, Bai-Fen; Cai, Zeng-Xuan; Xu, Xiao-Min; Ren, Yi-Ping

    2016-06-01

    A simple and reliable method of ultra high performance liquid chromatography coupled with photo-diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid-phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R(2) ≥ 0.999), acceptable recoveries (80.0-104.4%), and repeatability (RSDs 1.3-10.7%). The limits of detection (21.7-57.4 μg/kg) and quantitation (72.3-191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries' legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Improved micromethod for mezlocillin quantitation in serum and urine by high-pressure liquid chromatography.

    PubMed Central

    Fiore, D; Auger, F A; Drusano, G L; Dandu, V R; Lesko, L J

    1984-01-01

    A rapid, sensitive, and specific method of analysis for mezlocillin in serum and urine by high-pressure liquid chromatography is described. A solid-phase extraction column was used to remove interfering substances from samples before chromatography. Quantitation included the use of an internal standard, nafcillin. Mezlocillin was chromatographed with a phosphate buffer-acetonitrile (73:27) mobile phase and a C-18 reverse-phase column and detected at a wavelength of 220 nm. The assay had a sensitivity of 1.6 micrograms/ml and a linearity of up to 600 micrograms/ml and 16 mg/ml in serum and urine, respectively, with only 0.1 ml of sample. The interday and intraday coefficients of variation for replicate analyses of spiked serum and urine specimens were less than 6.5%. PMID:6517560

  5. [An ultra-high-pressure liquid chromatography/linear ion trap-Orbitrap mass spectrometry method coupled with a diagnostic fragment ions-searching-based strategy for rapid identification and characterization of chemical components in Polygonum cuspidatum].

    PubMed

    Pan, Zhiran; Liang, Hailong; Liang, Chabhufi; Xu, Wen

    2015-01-01

    A method for qualitative analysis of constituents in Polygonum cuspidatum by ultra-high-pressure liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry (UHPLC-LTQ-Orbitrap MS) has been established. The methanol extract of Polygonum cuspidatumrn was separated on a Waters UPLC C18 column using acetonitrile-water (containing formic acid) eluting system and detected by LTQ-Orbitrap hybrid mass spectrometer in negative mode. The targeted components were further fragmented in LTQ and high accuracy data were acquired by Orbitrap MS. The summarized fragmentation pathways of typical reference components and a diagnostic fragment ions-searching-based strategy were used for detection and identification of the main phenolic components in Polygonum cuspidatum. Other clues such as nitrogen rule, even electron rule, degree of unsaturation rule and isotopic peak data were included for the structural elucidation as well. The whole analytical procedure was within 10 min and more than 30 components were identified or tentatively identified. This method is helpful for further phytochemical research and quality control on Polygonum cuspidatum and related preparations.

  6. Intrinsic advantages of packed capillaries over narrow-bore columns in very high-pressure gradient liquid chromatography.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2016-06-17

    250μm×100mm fused silica glass capillaries were packed with 1.8μm high-strength silica (HSS) fully porous particles. They were prepared without bulky stainless steel endfittings and metal frits, which both generate significant sample dispersion. The isocratic efficiencies and gradient peak capacities of these prototype capillary columns were measured for small molecules (n-alkanophenones) using a home-made ultra-low dispersive micro-HPLC instrument. Their resolution power was compared to that of standard 2.1mm×100mm very high-pressure liquid chromatography (vHPLC) narrow-bore columns packed with the same particles. The results show that, for the same column efficiency (25000 plates) and gradient steepness (0.04min(-1)), the peak capacity of the 250μm i.d. capillary columns is systematically 15-20% higher than that of the 2.1mm i.d. narrow-bore columns. A validated model of gradient chromatography enabled one to predict accurately the observed peak capacities of the capillary columns for non-linear solvation strength retention behavior and under isothermal conditions. Thermodynamics applied to the eluent quantified the temperature difference for the thermal gradients in both capillary and narrow-bore columns. Experimental data revealed that the gradient peak capacity is more affected by viscous heating than the column efficiency. Unlike across 2.1mm i.d. columns, the changes in eluent composition across the 250μm i.d. columns during the gradient is rapidly relaxed by transverse dispersion. The combination of (1) the absence of viscous heating and (2) the high uniformity of the eluent composition across the diameter of capillary columns explains the intrinsic advantage of capillary over narrow-bore columns in gradient vHPLC. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Quantification aspects of constant pressure (ultra) high pressure liquid chromatography using mass-sensitive detectors with a nebulizing interface.

    PubMed

    Verstraeten, M; Broeckhoven, K; Lynen, F; Choikhet, K; Landt, K; Dittmann, M; Witt, K; Sandra, P; Desmet, G

    2013-01-25

    The present contribution investigates the quantitation aspects of mass-sensitive detectors with nebulizing interface (ESI-MSD, ELSD, CAD) in the constant pressure gradient elution mode. In this operation mode, the pressure is controlled and maintained at a set value and the liquid flow rate will vary according to the inverse mobile phase viscosity. As the pressure is continuously kept at the allowable maximum during the entire gradient run, the average liquid flow rate is higher compared to that in the conventional constant flow rate operation mode, thus shortening the analysis time. The following three mass-sensitive detectors were investigated: mass spectrometry detector (MS), evaporative light scattering detector (ELSD) and charged aerosol detector (CAD) and a wide variety of samples (phenones, polyaromatic hydrocarbons, wine, cocoa butter) has been considered. It was found that the nebulizing efficiency of the LC-interfaces of the three detectors under consideration changes with the increasing liquid flow rate. For the MS, the increasing flow rate leads to a lower peak area whereas for the ELSD the peak area increases compared to the constant flow rate mode. The peak area obtained with a CAD is rather insensitive to the liquid flow rate. The reproducibility of the peak area remains similar in both modes, although variation in system permeability compromises the 'long-term' reproducibility. This problem can however be overcome by running a flow rate program with an optimized flow rate and composition profile obtained from the constant pressure mode. In this case, the quantification remains reproducibile, despite any occuring variations of the system permeability. Furthermore, the same fragmentation pattern (MS) has been found in the constant pressure mode compared to the customary constant flow rate mode. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Simultaneous Determination of Food-Related Biogenic Amines and Precursor Amino Acids Using in Situ Derivatization Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction by Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry.

    PubMed

    He, Yongrui; Zhao, Xian-En; Wang, Renjun; Wei, Na; Sun, Jing; Dang, Jun; Chen, Guang; Liu, Zhiqiang; Zhu, Shuyun; You, Jinmao

    2016-11-02

    A simple, rapid, sensitive, selective, and environmentally friendly method, based on in situ derivatization ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) coupled with ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) using multiple reaction monitoring (MRM) mode has been developed for the simultaneous determination of food-related biogenic amines and amino acids. A new mass-spectrometry-sensitive derivatization reagent 4'-carbonyl chloride rosamine (CCR) was designed, synthesized, and first reported. Parameters and conditions of in situ DUADLLME and UHPLC-MS/MS were optimized in detail. Under the optimized conditions, the in situ DUADLLME was completed speedily (within 1 min) with high derivatization efficiencies (≥98.5%). With the cleanup and concentration of microextraction step, good analytical performance was obtained for the analytes. The results showed that this method was accurate and practical for quantification of biogenic amines and amino acids in common food samples (red wine, beer, wine, cheese, sausage, and fish).

  9. Determination of three estrogens and bisphenol A by functional ionic liquid dispersive liquid-phase microextraction coupled with ultra-high performance liquid chromatography and ultraviolet detection.

    PubMed

    Jiang, Yuehuang; Tang, Tingting; Cao, Zhen; Shi, Guoyue; Zhou, Tianshu

    2015-06-01

    A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0-1000 μg/L for estriol. The detection limits were in the range of 1.7-3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Determination of caffeoylquinic acids in feed and related products by focused ultrasound solid-liquid extraction and ultra-high performance liquid chromatography-mass spectrometry.

    PubMed

    Tena, M T; Martínez-Moral, M P; Cardozo, P W

    2015-06-26

    A method to determine caffeoylquinic acids (CQAs) in three sources (herbal extract, feed additive and finished feed) using for the first time focused ultrasound solid-liquid extraction (FUSLE) followed by ultra-high performance liquid chromatography (UPLC) coupled to quadrupole-time of flight mass spectrometry is presented. Pressurized liquid extraction (PLE) was also tested as extraction technique but it was discarded because cynarin was not stable under temperature values used in PLE. The separation of the CQAs isomers was carried out in only seven minutes. FUSLE variables such as extraction solvent, power and time were optimized by a central composite design. Under optimal conditions, FUSLE extraction was performed with 8mL of an 83:17 methanol-water mixture for 30s at a power of 60%. Only two extraction steps were found necessary to recover analytes quantitatively. Sensitivity, linearity, accuracy and precision were established. Matrix effect was studied for each type of sample. It was not detected for mono-CQAs, whereas the cynarin signal was strongly decreased due to ionization suppression in presence of matrix components; so the quantification by standard addition was mandatory for the determination of di-caffeoylquinic acids. Finally, the method was applied to the analysis of herbal extracts, feed additives and finished feed. In all samples, chlorogenic acid was the predominant CQA, followed by criptochlorogenic acid, neochlorogenic acid and cynarin. The method allows an efficient determination of chlorogenic acid with good recovery rates. Therefore, it may be used for screening of raw material and for process and quality control in feed manufacture. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    PubMed

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Rapid identif ication and comparative analysis of chemical constituents in herbal medicine Fufang decoction by ultra-high-pressure liquid chromatography coupled with a hybrid linear ion trap-high-resolution mass spectrometry.

    PubMed

    Cao, Gang; Chen, Xiaocheng; Wu, Xin; Li, Qinglin; Zhang, Hongyan

    2015-05-01

    This study was conducted to reveal the relation between herbal medicine Fufang decoction and a single drug in terms of material base. Da-Cheng-Qi decoction (DCQD) was used as a model. Ultrahigh-pressure liquid chromatography coupled with a hybrid linear ion trap-high-resolution mass spectrometry (UHPLC-LTQ-Orbitrap) was applied to detect and identify the main chemical compounds. This technique was also employed to determine the different chemical components. Under optimized liquid chromatography and mass spectrometry conditions, 64 components, including iridoids, flavonoids, anthraquinones and coumarins, were separated and tentatively characterized in Da-Cheng-Qi decoction. After decoction, the contents of 18 compounds were markedly changed, and two components were no longer detected in Fufang decoction compared with single-medicine decoction. The established method provided a good example for the rapid identification of complicated polar constituents in herbal medicine prescriptions. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Analysis of food polyphenols by ultra high-performance liquid chromatography coupled to mass spectrometry: an overview.

    PubMed

    Motilva, Maria-José; Serra, Aida; Macià, Alba

    2013-05-31

    Phenolic compounds, which are widely distributed in plant-derived foods, recently attracted much attention due to their health benefits, so their determination in food samples is a topic of increasing interest. In the last few years, the development of chromatographic columns packed with sub-2μm particles and the modern high resolution mass spectrometry (MS) have opened up new possibilities for improving the analytical methods for complex sample matrices, such as ingredients, foods and biological samples. In addition, they have emerged as an ideal tool for profiling complex samples due to its speed, efficiency, sensitivity and selectivity. The present review addresses the use of the improved liquid chromatography (LC), ultra-high performance LC (UHPLC), coupled to MS or tandem MS (MS/MS) as the detector system for the determination of phenolic compounds in food samples. Additionally, the different strategies to extract, quantify the phenolic compounds and to reduce the matrix effect (%ME) are also reviewed. Finally, a briefly outline future trends of UHPLC-MS methods is commented. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. [High-performance liquid-liquid chromatography in beverage analysis].

    PubMed

    Bricout, J; Koziet, Y; de Carpentrie, B

    1978-01-01

    Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.

  15. Use of ultra-high-pressure liquid chromatography-quadrupole time-of-flight MS to discover the presence of pesticide metabolites in food samples.

    PubMed

    Hernández, Félix; Grimalt, Susana; Pozo, Oscar J; Sancho, Juan V

    2009-07-01

    In this paper we illustrate the use of two different methodologies to investigate the presence of pesticide metabolites in parent pesticide-positive food samples, using ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight (UHPLC-QTOF) mass spectrometry. First, a common fragmentation pathway between the parent pesticide and its metabolites has been considered to search for metabolites in two positive market samples (imazalil in lemon, chlorpyrifos in grape). Secondly, olive oil samples from field residue trials were used for automated application of comparative software (MetaboLynx), which was used with treated and untreated samples to search for expected and unexpected metabolites of phosmet. One of the main objectives when using these approaches was to avoid the tedious manual searching for potential metabolites within the huge amount of information contained in the total ion chromatogram acquired by TOF MS. The common fragmentation approach applied to TOF MS full-acquisition data, considering an enhanced fragmentation in the collision cell, has allowed the discovery of two metabolites of imazalil (1-[2-(2,4-dichlorophenyl)-2-hydroxyethyl]-1H-imidazole and 1-[2-(2,4-dichlorophenyl)-2-oxoethyl]-1H-imidazole) in a lemon positive sample, as well as another two metabolites of chlorpyrifos (chlorpyrifos-oxon and 3,5,6-trichloro-2-pyridinol) in a grape positive sample. Moreover, MetaboLynx application to TOF MS data, without promoting fragmentation, from treated and untreated olive oil samples has been helpful in detecting the metabolite phosmet-oxon. In both strategies, every metabolite detected by TOF MS was confirmed using QTOF and/or triple quadrupole instruments. Accurate masses given by TOF MS together with the valuable information on product ions given by QTOF MS/MS experiments were crucial for the unambiguous identification of metabolites.

  16. Complete temperature profiles in ultra-high-pressure liquid chromatography columns.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-07-01

    The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C 18 particles, average d(p) approximately 1.7 microm) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than +/-0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

  17. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Yu, Kate; Little, David; Plumb, Rob; Smith, Brian

    2006-01-01

    A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.

  18. Ultra-high performance liquid chromatography tandem high-resolution mass spectrometry study of tricyclazole photodegradation products in water.

    PubMed

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Bolfi, Bianca; Marengo, Emilio

    2015-06-01

    This paper reports the study of the photodegradation reactions that tricyclazole can naturally undergo, under the action of sunlight, in aqueous solutions of standard tricyclazole and of the commercial BEAM(TM) formulation. The analyses are carried out by ultra-high performance liquid chromatography technique coupled with high-resolution tandem mass spectrometry. Analysis of both tricyclazole and BEAM(TM) water solutions undergone to hydrolysis does not evidence new chromatographic peaks with respect to the not treated solutions. On the contrary, analysis of the same samples subjected to sunlight irradiation shows a decreased intensity of tricyclazole signal and the presence of new chromatographic peaks. Two photodegradation products of tricyclazole have been identified, one of which has been also quantified, being the commercial standard available. The pattern is similar for the solutions of the standard fungicide and of the BEAM(TM) formulation. The results obtained from eco-toxicological tests show that toxicity of tricyclazole standard solutions is greater than that of the irradiated ones, whereas toxicity levels of all the BEAM(TM) solutions investigated (non-irradiated, irradiated, and hydrolyzed) are comparable and lower than those shown by tricyclazole standard solutions. Experiments performed in paddy water solution show that there is no difference in the degradation products formed.

  19. Simultaneous determination and qualitative analysis of six types of components in Naoxintong capsule by miniaturized matrix solid-phase dispersion extraction coupled with ultra high-performance liquid chromatography with photodiode array detection and quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, Huilin; Jiang, Yan; Ding, Mingya; Li, Jin; Hao, Jia; He, Jun; Wang, Hui; Gao, Xiu-Mei; Chang, Yan-Xu

    2018-02-03

    A simple and effective sample preparation process based on miniaturized matrix solid-phase dispersion was developed for simultaneous determination of phenolic acids (gallic acid, chlorogenic acid, ferulic acid, 3,5-dicaffeoylqunic acid, 1,5-dicaffeoylqunic acid, rosmarinic acid, lithospermic acid, and salvianolic acid B), flavonoids (kaempferol-3-O-rutinoside, calycosin, and formononetin), lactones (ligustilide and butyllidephthalide), monoterpenoids (paeoniflorin), phenanthraquinones (cryptotanshinone), and furans (5-hydroxymethylfurfural) in Naoxintong capsule by ultra high-performance liquid chromatography. The optimized condition was that 25 mg Naoxintong powder was blended homogeneously with 100 mg Florisil PR for 4 min. One milliliter of methanol/water (75:25, v/v) acidified by 0.05% formic acid was selected to elute all components. It was found that the recoveries of the six types of components ranged from 61.36 to 96.94%. The proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography was successfully applied to simultaneous determination of the six types of components in Naoxintong capsules. The results demonstrated that the proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography could be used as an environmentally friendly tool for the extraction and determination of multiple bioactive components in natural products. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Very high pressure liquid chromatography using fully porous particles: quantitative analysis of fast gradient separations without post-run times.

    PubMed

    Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois Ann; Guiochon, Georges

    2014-01-10

    Using a column packed with fully porous particles, four methods for controlling the flow rates at which gradient elution runs are conducted in very high pressure liquid chromatography (VHPLC) were tested to determine whether reproducible thermal conditions could be achieved, such that subsequent analyses would proceed at nearly the same initial temperature. In VHPLC high flow rates are achieved, producing fast analyses but requiring high inlet pressures. The combination of high flow rates and high inlet pressures generates local heat, leading to temperature changes in the column. Usually in this case a post-run time is input into the analytical method to allow the return of the column temperature to its initial state. An alternative strategy involves operating the column without a post-run equilibration period and maintaining constant temperature variations for subsequent analysis after conducting one or a few separations to bring the column to a reproducible starting temperature. A liquid chromatography instrument equipped with a pressure controller was used to perform constant pressure and constant flow rate VHPLC separations. Six replicate gradient separations of a nine component mixture consisting of acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide dissolved in water/acetonitrile (65:35, v/v) were performed under various experimental conditions: constant flow rate, two sets of constant pressure, and constant pressure operation with a programmed flow rate. The relative standard deviations of the response factors for all the analytes are lower than 5% across the methods. Programming the flow rate to maintain a fairly constant pressure instead of using instrument controlled constant pressure improves the reproducibility of the retention times by a factor of 5, when plotting the chromatograms in time. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Countercurrent chromatography separation of saponins by skeleton type from Ampelozizyphus amazonicus for off-line ultra-high-performance liquid chromatography/high resolution accurate mass spectrometry analysis and characterisation.

    PubMed

    de Souza Figueiredo, Fabiana; Celano, Rita; de Sousa Silva, Danila; das Neves Costa, Fernanda; Hewitson, Peter; Ignatova, Svetlana; Piccinelli, Anna Lisa; Rastrelli, Luca; Guimarães Leitão, Suzana; Guimarães Leitão, Gilda

    2017-01-20

    Ampelozizyphus amazonicus Ducke (Rhamnaceae), a medicinal plant used to prevent malaria, is a climbing shrub, native to the Amazonian region, with jujubogenin glycoside saponins as main compounds. The crude extract of this plant is too complex for any kind of structural identification, and HPLC separation was not sufficient to resolve this issue. Therefore, the aim of this work was to obtain saponin enriched fractions from the bark ethanol extract by countercurrent chromatography (CCC) for further isolation and identification/characterisation of the major saponins by HPLC and MS. The butanol extract was fractionated by CCC with hexane - ethyl acetate - butanol - ethanol - water (1:6:1:1:6; v/v) solvent system yielding 4 group fractions. The collected fractions were analysed by UHPLC-HRMS (ultra-high-performance liquid chromatography/high resolution accurate mass spectrometry) and MS n . Group 1 presented mainly oleane type saponins, and group 3 showed mainly jujubogenin glycosides, keto-dammarane type triterpene saponins and saponins with C 31 skeleton. Thus, CCC separated saponins from the butanol-rich extract by skeleton type. A further purification of group 3 by CCC (ethyl acetate - ethanol - water (1:0.2:1; v/v)) and HPLC-RI was performed in order to obtain these unusual aglycones in pure form. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. How High Pressure Unifies Solvation Processes in Liquid Chromatography.

    PubMed

    Bocian, Szymon; Škrinjar, Tea; Bolanca, Tomislav; Buszewski, Bogusław

    2017-11-01

    A series of core-shell-based stationary phases of varying surface chemistry were subjected to solvent adsorption investigation under ultra-HPLC conditions. Acetonitrile and water excess isotherms were measured using a minor disturbance method. It was observed that adsorption of organic solvent is unified under high pressure. Preferential solvation due to specific interactions between the stationary phases and solvent molecules was limited. The obtained results showed that the solvation process is almost independent of surface chemistry, in contrast to HPLC conditions in which specific interactions differentiate solvation processes.

  3. Rapid Quantitative Analysis of Naringenin in the Fruit Bodies of Inonotus vaninii by Two-phase Acid Hydrolysis Followed by Reversed Phase-high Performance Liquid Chromatography-ultra Violet.

    PubMed

    Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping

    2017-01-01

    Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii

  4. Rapid extraction and determination of 25 bioactive constituents in Alpinia oxyphylla using microwave extraction with ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Sun, Zhi; Kong, Xiangzhen; Zuo, Lihua; Kang, Jian; Hou, Lei; Zhang, Xiaojian

    2016-02-01

    A novel and rapid microwave extraction and ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of 25 bioactive constituents (including two new constituents) in Fructus Alpinia oxyphylla. The optimized conditions of the microwave extraction was a microwave power of 300 W, extraction temperature of 80°C, solvent-to-solid ratio of 30 mL/g and extraction time of 8 min. Separation was achieved on a Waters ACQUITY UPLC(®) HSS C18 column (2.1 mm× 50 mm, 1.8 μm) using gradient elution with a mobile phase consisting of acetonitrile and 1 mM ammonium acetate at a flow rate of 0.2 mL/min. This is the first report of the simultaneous determination of 25 bioactive constituents in Fructus Alpinia oxyphylla by ultra high performance liquid chromatography with tandem mass spectrometry. The method was validated with good linearity, acceptable precision and accuracy. The validated method was successfully applied to determine the contents of 25 bioactive constituents in Fructus Alpinia oxyphylla from different sources and the analysis results were classified by hierarchical cluster analysis, which indicated the effect of different cultivation regions on the contents of constituents. This study provides powerful and practical guidance in the quality control of Alpinia oxyphylla and lays the foundation for further research of Alpinia oxyphylla. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Simultaneous quantification of 5 main components of Psoralea corylifolia L. in rats' plasma by utilizing ultra high pressure liquid chromatography tandem mass spectrometry.

    PubMed

    Gao, Qianqian; Xu, Zisheng; Zhao, Genhua; Wang, Heng; Weng, Zebin; Pei, Ke; Wu, Li; Cai, Baochang; Chen, Zhipeng; Li, Weidong

    2016-02-01

    Psoralea corylifolia L. has long been used in traditional Chinese medicine for treating and preventing many diseases. A group of flavonoid components are regarded as the active principals within the seeds. In this research, a rapid, accurate and sensitive ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC/MS/MS) method has been established for simultaneous quantification of its 5 main components, namely, neobavaisoflavone, bavachin, isobavachalcone, bavachinin and corylifol A in rats' plasma after the rats were orally administrated with Buguzhi extract. Negative ion electrospray mode was applied in the detection process. Multiple reactions monitoring (MRM) mode was utilized for simultaneous quantitative analyzing of neobavaisoflavone (m/z 321.1→m/z 265.1), bavachin (m/z 323.1→m/z 119.0), isobavachalcone (m/z 323.2→m/z 119.0), bavachinin (m/z 337.2→m/z 119.0), corylifol A (m/z 389.2→m/z 277.0) and liquiritigenin (Internal Standard, m/z 255.1→m/z 119.0). Chromatographic separation of the above mentioned components was conducted on a Waters BEH-C18 column (100 mm×2.1mm, 1.7μm) with gradient elution system at flow rate of 0.3mL/min. The mobile phase was composed of acetonitrile and 0.1% formic acid solution. The lower limit of quantification (LLOQ) for each of the above analytes was 0.5ng/mL. Each of the analytes exhibited good linearity within the concentration range of 0.5-100ng/mL. The method was fully validated for its selectivity, accuracy, precision, stability, matrix effect and extraction recovery. The validated method has been successfully applied for simultaneous determination of the 5 flavonoids in rat plasma for the first time. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Detection of anabolic and androgenic steroids and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry.

    PubMed

    Kwok, Karen Y; Choi, Timmy L S; Kwok, Wai Him; Wong, Jenny K Y; Wan, Terence S M

    2017-04-14

    Anabolic and androgenic steroids (AASs) are a class of prohibited substances banned in horseracing at all times. The common approach for controlling the misuse of AASs in equine sports is by detecting the presence of AASs and/or their metabolites in urine and blood samples using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This approach, however, often falls short as the duration of effect for many AASs are longer than their detection time in both urine and blood. As a result, there is a high risk that such AASs could escape detection in their official race-day samples although they may have been used during the long period of training. Hair analysis, on the other hand, can afford significantly longer detection windows. In addition, the identification of synthetic ester derivatives of AASs in hair, particularly for the endogenous ones, can provide unequivocal proof of their exogenous origin. This paper describes the development of a sensitive method (at sub to low parts-per-billion or ppb levels) for detecting 48 AASs and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS). Decontaminated horse hair was pulverised and subjected to in-situ liquid-liquid extraction in a mixture of hexane - ethyl acetate (7:3, v/v) and phosphate buffer (0.1M, pH 9.5), followed by additional clean-up using mixed-mode solid-phase extraction. The final extract was analysed using UHPLC-HRMS in the positive electrospray ionisation (ESI) mode with both full scan and parallel reaction monitoring (PRM). This method was validated for qualitative identification purposes. Validation data, including method specificity, method sensitivity, extraction recovery, method precision and matrix effect are presented. Method applicability was demonstrated by the successful detection and confirmation of testosterone propionate in a referee hair sample. To our knowledge, this was

  7. High-pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, C.G.; Sakaji, R.H.

    1982-09-08

    A gradient mixer effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum band-broadening.

  8. Rapid and automated analysis of aflatoxin M1 in milk and dairy products by online solid phase extraction coupled to ultra-high-pressure-liquid-chromatography tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2016-01-08

    This study reports a fast and automated analytical procedure for the analysis of aflatoxin M1 (AFM1) in milk and dairy products. The method is based on the simultaneous protein precipitation and AFM1 extraction, by salt-induced liquid-liquid extraction (SI-LLE), followed by an online solid-phase extraction (online SPE) coupled to ultra-high-pressure-liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis to the automatic pre-concentration, clean up and sensitive and selective determination of AFM1. The main parameters affecting the extraction efficiency and accuracy of the analytical method were studied in detail. In the optimal conditions, acetonitrile and NaCl were used as extraction/denaturant solvent and salting-out agent in SI-LLE, respectively. After centrifugation, the organic phase (acetonitrile) was diluted with water (1:9 v/v) and purified (1mL) by online C18 cartridge coupled with an UHPLC column. Finally, selected reaction monitoring (SRM) acquisition mode was applied to the detection of AFM1. Validation studies were carried out on different dairy products (whole and skimmed cow milk, yogurt, goat milk, and powder infant formula), providing method quantification limits about 25 times lower than AFM1 maximum levels permitted by EU regulation 1881/2006 in milk and dairy products for direct human consumption. Recoveries (86-102%) and repeatability (RSD<3, n=6) meet the performance criteria required by EU regulation N. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. Moreover, no matrix effects were observed in the different milk and dairy products studied. The proposed method improves the performance of AFM1 analysis in milk samples as AFM1 determination is performed with a degree of accuracy higher than the conventional methods. Other advantages are the reduction of sample preparation procedure, time and cost of the analysis, enabling high sample throughput that meet the current concerns of food safety and the public

  9. A strategy for screening antioxidants in Ginkgo biloba extract by comprehensive two-dimensional ultra high performance liquid chromatography.

    PubMed

    Guo, Ru-Zhou; Liu, Xin-Guang; Gao, Wen; Dong, Xin; Fanali, Salvatore; Li, Ping; Yang, Hua

    2015-11-27

    Recently, screening of bioactive compounds by on-line ultra-high performance liquid chromatography (UHPLC) draws increasing attentions for the advantages of rapidity and intuition. Nevertheless, most on-line methods were limited to the shortcoming like low resolution and peak capacity, which could interfere the active ingredient identification. Comprehensive two-dimensional UHPLC (LC×LC) has revealed to be a powerful tool to separate complex mixtures. Herein, a strategy based on LC×LC analysis coupled with pre-column 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay was proposed to screen the antioxidants from the extract of Ginkgo biloba (EGB). A total of 61 compounds were identified in EGB, and 25 of them showed appreciable radical scavenging capacity. This work may offer pharmacodynamics base for further research about EGB, also the strategy is likelihood to be applied in screening antioxidant in other herbal medicine. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. [Polycyclic aromatic hydrocarbons in ultrafine particles of diesel exhaust fumes--the use of ultrafast liquid chromatography].

    PubMed

    Małgorzata Szewczyńska; Małgorzata Pośniak

    2014-01-01

    The article presents the results of the determination of polycyclic aromatic hydrocarbons (PAHs) in the fine par ticles fraction emitted from 3 types of diesel fuels using ultra-high pressure liquid chromatography. Samples of diesel Eco, Verwa and Bio exhaust combustion fumes were generated at the model station which consisted of a diesel engine from the 2007 Diesel TDI 2.0. Personal Cascade Sioutas Impactor (IPCSI) with Teflon filters was used to collect samples of exhaust fume ultrafine particles. PAHs adsorbed on particulate fractions were analyzed by ultra-high pressure liquid chromatography with fluorescence detection (UHPLC/FL). Phenanthrene, fluoranthene, pyrene and chrysene present the highest concentration in the particulate matter emitted by an engine. The total contents of fine particles collected during engine operation on fuels Eco, Verwa and Bio were 134.2 μg/g, 183.8 μg/g and 153.4 μg/g, respectively, which makes 75%, 90% and 83% of the total PAHs, respectively. The highest content of benzo(a)pyrene determined in particles emitted during the combustion of fuels Eco and Bio was 1.5 μg/g and 1 μg/g, respectively. The study of the PAH concentration in the particles of fine fraction below 0.25 μm emitted from different fuels designed for diesel engines indicate that the exhaust gas content of carcinogens, including PAHs deposited on particulates, is still significant, regardless of the fuel. Application of ultrahigh pressure liquid chromatography with fluorescence detection for the analysis ofPAHs in the particles emitted in the fine fraction of diesel exhaust allowed to shorten the analysis time from 35 min to 8 min.

  11. Determination of sedative hypnotics in sewage sludge by pressurized liquid extraction with high-performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Arbeláez, Paula; Granados, Judith; Borrull, Francesc; Marcé, Rosa Maria; Pocurull, Eva

    2014-12-01

    This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9-18.9 μg/kg dry weight). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. [Determination of six anticoccidials in chicken using QuEChERS combined with ultra high liquid chromatography-high resolution mass spectrometry].

    PubMed

    Muharem, Muhteber; Yan, Hua; Xu, Shan; Feng, Nan; Hao, Jie; Zhu, Chenqi; Guo, Shuang; Zhang, Zhaohui; Han, Nanyin

    2015-11-01

    An ultra high liquid chromatography-Q Exactive orbitrap mass spectrometry multi-residue method has been developed for the determination of six anticoccidials residues (dinitlmide, nicarbazin, diclazuril, toltrazuril, monensin and salinomycin) in chicken tissue. Sample preparation was based on QuEChERS method, using 1% (v/v) trichloroacetic acid/acetonitrile aqueous solution (3:7, v/v) as the extraction solvent and salting-out with sodium chloride followed by clean-up with 50 mg/mL primary secondary amine (PSA) +50 mg/mL neutral alumina (Alumina-N) dispersive solid phase extraction (DSPE). The separation of the compounds in liquid chromatography was carried out using a Waters Acquity UPLC BEH C8 column (100 mm x 2.1 mm, 1.7 μm) with mobile phases consisting of methanol-5 mmol/L ammonium acetate aqueous solution in gradient elution. The Q Exactive orbitrap mass spectrometric detection was carried out with positive and negative electrospray ionization simultaneously. The results showed the linear ranges of the six target compounds were as follows: dinitolmide, 1.0-30.0 μg/L; nicarbazin, 0.2-6.0 μg/L; diclazuril and toltrazuril, 2.0-60.0 [μg/L; monensin and salinomycin, 4.0-120.0 μg/L. The external standard method was used for quantification. The spiked recoveries at three levels for the six anticoccidials ranged from 67.7% to 126.8%. The relative standard deviations (RSDs) were ≤ 10.4%. The limits of quantification (LOQs) were as follows: dinitolmide, 2.50 μg/kg; nicarbazin, 0.50 μg/kg; diclazuril and toltrazuril, 5.00 μg/kg; monensin and salinomycin, 20.00 μg/kg. The developed method is easy of operation and of high sensitivity. It can meet the requirements of daily inspection.

  13. Ultra-high pressure liquid chromatography-tandem mass spectrometry method for the determination of omarigliptin in rat plasma and its application to a pharmacokinetic study in rats.

    PubMed

    Li, Meng-Fang; Hu, Xiao-Xia; Ma, Ai-Qun

    2017-10-01

    Omarigliptin is a novel long-acting dipeptidyl peptidase-4 inhibitor used for the treatment of type 2 diabetes. In this work, a sensitive and selective ultra-high pressure liquid chromatography tandem mass spectrometry method was developed and validated for the determination of omarigliptin in rat plasma. Sample preparation was performed by protein precipitation with acetonitrile. Chromatographic separation of analytes was achieved on an RRHD Eclipse Plus C18 column (2.1 × 50 mm, 1.8 μm), using gradient mobile phase (0.1% formic acid-acetonitrile) at a flow rate of 0.4 mL/min. Detection was performed in multiple reaction monitoring mode, with target fragment ions m/z 399.1 → 152.9 for omarigliptin and m/z 237.1 → 194 for the internal standard. The total run time was 4 min. Retention time of omarigliptin and internal standard was 1.25 and 2.12 min, respectively. Relative standard deviation (%) of the intra- and inter-day precision was below 10.0%, and accuracy was between 97.9% and 105.3%. Calibration curve was established over the range 2-5000 ng/mL with good linearity. The lower limit of quantification and limit of detection of omarigliptin were 2 and 0.25 ng/mL, respectively. Mean recoveries were in the range 87.3-95.1% for omarigliptin. No matrix effect was observed in this method. This novel method has been successfully applied to a pharmacokinetic study of omarigliptin in rats. The absolute bioavailability of omarigliptin was identified as high as 87.31%. Copyright © 2017 John Wiley & Sons, Ltd.

  14. New approach to the determination phosphorothioate oligonucleotides by ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry.

    PubMed

    Studzińska, Sylwia; Mounicou, Sandra; Szpunar, Joanna; Łobiński, Ryszard; Buszewski, Bogusław

    2015-01-15

    This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of (31)P may be used to quantify these compounds at the level of 80 μg L(-1), while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L(-1). The limit of detection was in the range of 0.07 and 0.13 mg L(-1). Accuracy varied with concentration, but was in the range of 3%. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A selective biomarker for confirming nitrofurazone residues in crab and shrimp using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Shuai; Guo, Yuanming; Yan, Zhongyong; Sun, Xiumei; Zhang, Xiaojun

    2015-12-01

    Reliably detecting nitrofurazone (NFZ) residues in farmed crab and shrimp was previously hindered by lack of appropriately specific analytical methodology. Parent NFZ rapidly breaks down in meat, and the commonly used side-chain metabolite, semicarbazide (SEM), is non-specific as it occurs naturally in crustacean shell often leading to 'false positive' detections in meat. Using 5-nitro-2-furaldehyde (NF) as marker metabolite, following pre-column derivatization with 2,4-dinitrophenylhydrazine (DNPH), ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis in negative electrospray ionization mode enabled confirmation of NFZ residues in deliberately treated whole crab, crab meat and shrimp meat, with a limit of detection (LOD) and limit of quantification (LOQ) below 1 ng g(-1). Meanwhile, the derivatives of DNPH-NF were synthesized for the first time, purified by preparative liquid chromatography and structure characterized with nuclear magnetic resonance spectroscopy ((1)H-NMR). The purity of derivative was checked by ultra-performance liquid chromatography-tunable ultraviolet (UPLC-TUV), and the contents were beyond 99.9%. For comparison purposes, crustacean samples were analysed using both NF and SEM marker metabolites. NFZ treatment was revealed by both NF and SEM marker metabolites, but untreated crab also showed measurable levels of SEM which could potentially be misinterpreted as evidence of illegal NFZ use.

  16. Trace determination of organophosphate esters in white wine, red wine, and beer samples using dispersive liquid-liquid microextraction combined with ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Pang, Long; Yang, Huiqiang; Yang, Peijie; Zhang, Hongzhong; Zhao, Jihong

    2017-08-15

    In this study, dispersive liquid-liquid microextraction coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry was developed for the analysis of five representative organophosphate esters (OPEs) in wine samples. Under optimized conditions, the proposed method resulted in good linearity (R 2 >0.9933) over the range of 0.1-100μgL -1 , with limits of detection (LODs, S/N =3) and quantification (LOQs, S/N =10) in the ranges of 0.48-18.8ngL -1 and 1.58-62.5ngL -1 , respectively. Inter- and intra-assay precisions of RSD% ranged from 3.21% to 6.13% and from 1.69% to 7.63%, respectively. The spiked recoveries of target OPEs from white wine, red wine, and beer samples were in the ranges of 80-122%, 76-120%, and 76-110%, respectively, at two different concentration levels. The total concentrations of five OPEs found in white wine, red wine, and beer samples were in the ranges of 0.29-0.85μgL -1 , 1.00-3.05μgL -1 , and 0.86-1.47μgL -1 , respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Implementation of high slurry concentration and sonication to pack high-efficiency, meter-long capillary ultrahigh pressure liquid chromatography columns.

    PubMed

    Godinho, Justin M; Reising, Arved E; Tallarek, Ulrich; Jorgenson, James W

    2016-09-02

    Slurry packing capillary columns for ultrahigh pressure liquid chromatography is complicated by many interdependent experimental variables. Previous results have suggested that combination of high slurry concentration and sonication during packing would create homogeneous bed microstructures and yield highly efficient capillary columns. Herein, the effect of sonication while packing very high slurry concentrations is presented. A series of six, 1m×75μm internal diameter columns were packed with 200mg/mL slurries of 2.02μm bridged-ethyl hybrid silica particles. Three of the columns underwent sonication during packing and yielded highly efficient separations with reduced plate heights as low as 1.05. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Extending the limits of operating pressure of narrow-bore column liquid chromatography instrumentation.

    PubMed

    Pauw, Ruben De; Degreef, Bart; Ritchie, Harald; Eeltink, Sebastiaan; Desmet, Gert; Broeckhoven, Ken

    2014-06-20

    The increase of the operating pressure in Liquid Chromatography, has been one of the crucial steps toward faster and more efficient separations. In the present contribution, it was investigated if the pressure limits for narrow-bore columns (2.1mm ID) could be increased beyond those of commercially available (1300bar) instrumentation without performance loss. Whereas previous studies applying pressures higher than 2000bar were limited to the use of columns with a diameter smaller or equal to 1mm, it is a difficult feat to expand this to 2.1mm ID given that viscous-heating effects increase according to the fifth power of the column radius. A prototype LC set-up was realized, allowing to operate at pressures up to 2600bar (260MPa) for large separation volumes (>5mL). The performance of an in-house-built injector was compared at 800bar to commercially available injectors, yielding equal performance but twice the maximum pressure rating. The performance of (coupled) custom columns packed with fully porous and superficially porous particles were assessed at ultra-high-pressure conditions. Increasing the inlet pressure from 800 to 2400bar and scaling the column length proportionally (from 150mm to 450mm), resulted in the theoretically expected linear increase in plate count from 20,000 to 59,000. A maximum plate number of 81,000 was realized using a 600mm long (coupled) column at 2600bar. Viscous-heating effects were diminished by insulating coupled columns and applying an intermediate-cooling strategy in a forced-air oven. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Metabolite characterization of a novel sedative drug, remimazolam in human plasma and urine using ultra high-performance liquid chromatography coupled with synapt high-definition mass spectrometry.

    PubMed

    Zhou, Ying; Hu, Pei; Jiang, Ji

    2017-04-15

    Remimazolam is a new chemical entity belonging to the benzodiazepine class of sedative drugs, which shows faster-acting onset and recovery than currently available short-acting sedatives. In the present study, ultra high performance liquid chromatography with synapt high-definition mass spectrometry method combined with MassLynx software was established to characterize metabolites of remimazolam in human plasma and urine. In total, 5 human metabolites were detected, including 3 phase I and 2 phase II metabolites. There was no novel human metabolite detected compared to that in rat. Hydrolysis, glucuronidation and oxidation were the major metabolic reactions. To our knowledge, this is the first report of the human metabolic profile of remimazolam. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. High pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, Christian G.; Sakaji, Richard H.

    1985-01-01

    A gradient mixer which effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum "band-broadening".

  1. Multi-component determination and chemometric analysis of Paris polyphylla by ultra high performance liquid chromatography with photodiode array detection.

    PubMed

    Chen, Pei; Jin, Hong-Yu; Sun, Lei; Ma, Shuang-Cheng

    2016-09-01

    Multi-source analysis of traditional Chinese medicine is key to ensuring its safety and efficacy. Compared with traditional experimental differentiation, chemometric analysis is a simpler strategy to identify traditional Chinese medicines. Multi-component analysis plays an increasingly vital role in the quality control of traditional Chinese medicines. A novel strategy, based on chemometric analysis and quantitative analysis of multiple components, was proposed to easily and effectively control the quality of traditional Chinese medicines such as Chonglou. Ultra high performance liquid chromatography was more convenient and efficient. Five species of Chonglou were distinguished by chemometric analysis and nine saponins, including Chonglou saponins I, II, V, VI, VII, D, and H, as well as dioscin and gracillin, were determined in 18 min. The method is feasible and credible, and enables to improve quality control of traditional Chinese medicines and natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Integration of Electrochemistry with Ultra Performance Liquid Chromatography/Mass Spectrometry (UPLC/MS)

    PubMed Central

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A.; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of disulfide bond-containing proteins/peptides. In our approach, a protein/peptide mixture sample undergoes fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and MS/MS analyses. The electrochemical cell is coupled to MS using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, disulfide bond-containing peptides can be differentiated from those without disulfide bonds as the former are electroactive and reducible. Tandem MS analysis of the disulfide-reduced peptide ions provides increased sequence and disulfide linkage pattern information. In a reactive DESI-MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which would be useful in top-down protein structure analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1~2 orders of magnitude by using UPLC for the LC/EC/MS platform, in comparison to the previously used high performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis. PMID:26307715

  3. Miniaturised electrically actuated high pressure injection valve for portable capillary liquid chromatography.

    PubMed

    Li, Yan; Pace, Kirsten; Nesterenko, Pavel N; Paull, Brett; Stanley, Roger; Macka, Mirek

    2018-04-01

    A miniaturised high pressure 6-port injection valve has been designed and evaluated for its performance in order to facilitate the development of portable capillary high performance liquid chromatography (HPLC). The electrically actuated valve features a very small size (65 × 19 × 19mm) and light weight (33g), and therefore can be easily integrated in a miniaturised modular capillary LC system suited for portable field analysis. The internal volume of the injection valve was determined as 98 nL. The novel conical shape of the stator and rotor and the spring-loaded rotor performed well up to 32MPa (4641psi), the maximum operating pressure investigated. Suitability for application was demonstrated using a miniaturised capillary LC system applied to the chromatographic separation of a mixture of biogenic amines and common cations. The RSD (relative standard deviation) values of retention times and peak areas of 6 successive runs were 0.5-0.7% and 1.8-2.8% for the separation of biogenic amines, respectively, and 0.1-0.2% and 2.1-3.0% for the separation of cations, respectively. This performance was comparable with bench-top HPLC systems thus demonstrating the applicability of the valve for use in portable and miniaturised capillary HPLC systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid ChromatographyTime-of-Flight Mass Spectrometry

    DTIC Science & Technology

    2016-04-01

    QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID-PHASE EXTRACTION ULTRA-PERFORMANCE...TITLE AND SUBTITLE Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid Chromatography... food matrices. The mixed-mode cation exchange (MCX) sorbent and Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods were used for

  5. Dual ultrasonic-assisted dispersive liquid-liquid microextraction coupled with microwave-assisted derivatization for simultaneous determination of 20(S)-protopanaxadiol and 20(S)-protopanaxatriol by ultra high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying

    2016-03-11

    This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Comprehensive polyphenol profiling of a strawberry extract (Fragaria × ananassa) by ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry.

    PubMed

    La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2017-03-01

    The aim of metabolic untargeted profiling is to detect and identify unknown compounds in a biological matrix to achieve the most comprehensive metabolic coverage. In phytochemical mixtures, however, the complexity of the sample could present significant difficulties in compound identification. In this case, the optimization of both the chromatographic and the mass-spectrometric conditions is supposed to be crucial for the detection and identification of the largest number of compounds. In this work, a systematic investigation of different chromatographic and mass-spectrometric conditions is presented to achieve a comprehensive untargeted profiling of a strawberry extract (Fragaria × ananassa). To fulfill this aim, an ultra-high-pressure liquid chromatography system coupled via an electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer was used. Spectra were acquired in data-dependent mode, and several parameters were investigated to acquire the largest possible number of both mass spectrometry (MS) features and MS 2 mass spectra for unique metabolites. The main classes of polyphenols studied were flavonoids, phenolic acids, dihydrochalcones, ellagitannins, and proanthocyanidins. Method optimization allowed to us identify and tentatively identify 18 and 113 compounds, respectively, among which 74 have never been reported before in strawberries and, to the best of our knowledge, 22 of them have never been reported before. The results show the importance of an extended investigation of the chromatographic and mass-spectrometric method before a complete untargeted profiling of complex phytochemical mixtures.

  7. A multiresidue approach for the simultaneous quantification of antibiotics in macroalgae by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Leston, Sara; Freitas, Andreia; Rosa, João; Barbosa, Jorge; Lemos, Marco F L; Pardal, Miguel Ângelo; Ramos, Fernando

    2016-10-15

    Together with fish, algae reared in aquaculture systems have gained importance in the last years, for many purposes. Besides their use as biofilters of effluents, macroalgae's rich nutritional profiles have increased their inclusion in human diets but also in animal feeds as sources of fatty acids, especially important for the fish industry. Nonetheless, algae are continuously exposed to environmental contaminants including antibiotics and possess the ability for bioaccumulation of such compounds. Therefore, the present paper describes the development and validation of an ultra-high performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of antibiotics in the green macroalgae Ulva lactuca. This multi-residue method enables the determination of 38 compounds distributed between seven classes and was fully validated according to EU Decision 2002/657/EC. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Determination of teicoplanin concentrations in serum by high-pressure liquid chromatography.

    PubMed Central

    Joos, B; Lüthy, R

    1987-01-01

    An isocratic reversed-phase high-pressure liquid chromatographic method for the determination of six components of the teicoplanin complex in biological fluid was developed. By using fluorescence detection after precolumn derivatization with fluorescamine, the assay is specific and highly sensitive, with reproducibility studies yielding coefficients of variation ranging from 1.5 to 8.5% (at 5 to 80 micrograms/ml). Response was linear from 2.5 to 80 micrograms/ml (r = 0.999); the recovery from spiked human serum was 76%. An external quality control was performed to compare this high-pressure liquid chromatographic method (H) with a standard microbiological assay (M); no significant deviation from slope = 1 and intercept = 0 was found by regression analysis (H = 1.03M - 0.45; n = 15). PMID:2957953

  9. Constant pressure mode extended simple gradient liquid chromatography system for micro and nanocolumns.

    PubMed

    Šesták, Jozef; Kahle, Vladislav

    2014-07-11

    Performing gradient liquid chromatography at constant pressure instead of constant flow rate has serious potential for shortening the analysis time and increasing the productivity of HPLC instruments that use gradient methods. However, in the constant pressure mode the decreasing column permeability during a long period of time negatively affects the repeatability of retention time. Thus a volume-based approach, in which the detector signal is plotted as a function of retention volume, must be taken into consideration. Traditional HPLC equipment, however, requires quite complex hardware and software modifications in order to work at constant pressure and in the volume-based mode. In this short communication, a low cost and easily feasible pressure-controlled extension of the previously described simple gradient liquid chromatography platform is proposed. A test mixture of four nitro esters was separated by 10-60% (v/v) acetone/water gradient and a high repeatability of retention volumes at 20MPa (RSD less than 0.45%) was realized. Separations were also performed at different values of pressure (20, 25, and 31MPa), and only small variations of the retention volumes (up to 0.8%) were observed. In this particular case, the gain in the analysis speed of 7% compared to the constant flow mode was realized at a constant pressure. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Screening bioactive quality control markers of QiShenYiQi dripping pills based on the relationship between the ultra-high performance liquid chromatography fingerprint and vascular protective activity.

    PubMed

    Zhuo, Limeng; Peng, Jingjing; Zhao, Yunli; Li, Dongxiang; Xie, Xiuman; Tong, Ling; Yu, Zhiguo

    2017-10-01

    Traditional Chinese medicine consists of complex phytochemical constituents. Selecting appropriate analytical markers of traditional Chinese medicine is a critical step in quality control. Currently, the combination of fingerprinting and efficacy evaluation is considered as a useful method for screening active ingredients in complex mixtures. This study was designed to develop an orthogonal partial least squares model for screening bioactive quality control markers of QishenYiqi dripping pills based on the fingerprint-efficacy relationship. First, the chemical fingerprints of 49 batches of QishenYiqi dripping pill samples were established by ultra-high performance liquid chromatography coupled with a photodiode array detector. Second, ultra-high performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry was exploited to systematically investigate the 36 copossessing fingerprint components in QishenYiqi dripping pills. The vascular protective activity of QishenYiqi dripping pills was determined by using a cell counting kit-8 assay. Finally, fingerprint-efficacy relationship was established by orthogonal partial least squares model. The results indicated that ten components exhibited strong correlation with vascular protective activity, and these were preliminarily screened as quality control markers. The present study provided a novel idea for the study of the pharmacodynamic material basis and quality evaluation of QishenYiqi dripping pills. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Analysis of Poly-β-Hydroxybutyrate in Rhizobium japonicum Bacteroids by Ion-Exclusion High-Pressure Liquid Chromatography and UV Detection †

    PubMed Central

    Karr, Dale B.; Waters, James K.; Emerich, David W.

    1983-01-01

    Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443

  12. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    PubMed

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez

    2011-07-15

    A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp.

    PubMed

    Chen, Guoqiang; Hoptroff, Michael; Fei, Xiaoqing; Su, Ya; Janssen, Hans-Gerd

    2013-11-22

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal standard. Atmospheric pressure chemical ionization (APCI) in positive mode was applied for the detection of climbazole. For quantification, multiple reaction monitoring (MRM) transition 293.0>69.0 was monitored for climbazole, and MRM transition 296.0>225.1 for the deuterated climbazole. The linear range ran from 4 to 2000 ng mL(-1). The limit of detection (LOD) and the limit of quantification (LOQ) were 1 ng mL(-1) and 4 ng mL(-1), respectively, which enabled quantification of climbazole on artificial skin and human scalp at ppb level (corresponding to 16 ng cm(-2)). For the sampling of climbazole from human scalp the buffer scrub method using a surfactant-modified phosphate buffered saline (PBS) solution was selected based on a performance comparison of tape stripping, the buffer scrub method and solvent extraction in in vitro studies. Using this method, climbazole deposition in in vitro and in vivo studies was successfully quantified. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Metabolomic characterization of rhubarb species by capillary electrophoresis and ultra-high-pressure liquid chromatography.

    PubMed

    Tseng, Yufeng Jane; Kuo, Chun-Ting; Wang, San-Yuan; Liao, Hsiao-Wei; Chen, Guan-Yuan; Ku, Yuan-Ling; Shao, Wei-Cheng; Kuo, Ching-Hua

    2013-10-01

    This study developed CE and ultra-high-pressure LC (UHPLC) methods coupled with UV detectors to characterize the metabolomic profiles of different rhubarb species. The optimal CE conditions used a BGE with 15 mM sodium tetraborate, 15 mM sodium dihydrogen phosphate monohydrate, 30 mM sodium deoxycholate, and 30% ACN v/v at pH 8.3. The optimal UHPLC conditions used a mobile phase composed of 0.05% phosphate buffer and ACN with gradient elution. The gradient profile increased linearly from 10 to 21% ACN within the first 25 min, then increased to 33% ACN for the next 10 min. It took another 5 min to reach the 65% ACN, then for the next 5 min, it stayed unchanged. Sixteen samples of Rheum officinale and Rheum tanguticum collected from various locations were analyzed by CE and UHPLC methods. The metabolite profiles of CE were aligned and baseline corrected before chemometric analysis. Metabolomic signatures of rhubarb species from CE and UHPLC were clustered using principle component analysis and distance-based redundancy analysis; the clusters were not only able to discriminate different species but also different cultivation regions. Similarity measurements were performed by calculating the correlation coefficient of each sample with the authentic samples. Hybrid rhizome was clearly identified through similarity measurement of UHPLC metabolite profile and later confirmed by gene sequencing. The present study demonstrated that CE and UHPLC are efficient and effective tools to identify and authenticate herbs even coupled with simple detectors. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Identification of Ginkgo biloba supplements adulteration using high performance thin layer chromatography and ultra high performance liquid chromatography-diode array detector-quadrupole time of flight-mass spectrometry.

    PubMed

    Avula, Bharathi; Sagi, Satyanarayanaraju; Gafner, Stefan; Upton, Roy; Wang, Yan-Hong; Wang, Mei; Khan, Ikhlas A

    2015-10-01

    Ginkgo biloba is one of the most widely sold herbal supplements and medicines in the world. Its popularity stems from having a positive effect on memory and the circulatory system in clinical studies. As ginkgo popularity increased, non-proprietary extracts were introduced claiming to have a similar phytochemical profile as the clinically tested extracts. The standardized commercial extracts of G. biloba leaf used in ginkgo supplements contain not less than 6% sesquiterpene lactones and 24% flavonol glycosides. While sesquiterpene lactones are unique constituents of ginkgo leaf, the flavonol glycosides are found in many other botanical extracts. Being a high value botanical, low quality ginkgo extracts may be subjected to adulteration with flavonoids to meet the requirement of 24% flavonol glycosides. Chemical analysis by ultra high performance liquid chromatography-mass spectrometry revealed that adulteration of ginkgo leaf extracts in many of these products is common, the naturally flavonol glycoside-rich extract being spiked with pure flavonoids or extracts made from another flavonoid-rich material, such as the fruit/flower of Japanese sophora (Styphnolobium japonicum), which also contains the isoflavone genistein. Recently, genistein has been proposed as an analytical marker for the detection of adulteration of ginkgo extracts with S. japonicum. This study confirms that botanically authenticated G. biloba leaf and extracts made therefrom do not contain genistein, and the presence of which even in trace amounts is suggestive of adulteration. In addition to the mass spectrometric approach, a high performance thin layer chromatography method was developed as a fast and economic method for chemical fingerprint analysis of ginkgo samples.

  17. Determination of anthelmintic drug residues in milk using ultra high performance liquid chromatography-tandem mass spectrometry with rapid polarity switching.

    PubMed

    Whelan, Michelle; Kinsella, Brian; Furey, Ambrose; Moloney, Mary; Cantwell, Helen; Lehotay, Steven J; Danaher, Martin

    2010-07-02

    A new UHPLC-MS/MS (ultra high performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added concentration step to detect most of the analytes at <1 microg kg(-1) levels in milk. Anthelmintic residues were extracted into acetonitrile using magnesium sulphate and sodium chloride to induce liquid-liquid partitioning followed by dispersive solid phase extraction for cleanup. The extract was concentrated into dimethyl sulphoxide, which was used as a keeper to ensure analytes remain in solution. Using rapid polarity switching in electrospray ionisation, a single injection was capable of detecting both positively and negatively charged ions in a 13 min run time. The method was validated at two levels: the unapproved use level and at the maximum residue level (MRL) according to Commission Decision (CD) 2002/657/EC criteria. The decision limit (CCalpha) of the method was in the range of 0.14-1.9 and 11-123 microg kg(-1) for drugs validated at unapproved and MRL levels, respectively. The performance of the method was successfully verified for benzimidazoles and levamisole by participating in a proficiency study.

  18. Comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for analysis of toad skin.

    PubMed

    Li, Jia-Fu; Yan, Xia; Wu, Yun-Long; Fang, Mei-Juan; Wu, Zhen; Qiu, Ying-Kun

    2017-04-15

    An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Rapid purification of staphylococcal enterotoxin B by high-pressure liquid chromatography.

    PubMed Central

    Strickler, M P; Neill, R J; Stone, M J; Hunt, R E; Brinkley, W; Gemski, P

    1989-01-01

    The Staphylococcus aureus enterotoxins represent a group of proteins that cause emesis and diarrhea in humans and other primates. We have developed a rapid two-step high-pressure liquid chromatography (HPLC) procedure for purification of staphylococcal enterotoxin B (SEB). Sterile filtrates (2.5 liters) of strain 10-275 were adsorbed directly onto a reversed-phase column (50 mm by 30 cm Delta Pak; 300 A [30 nm], 15 microns, C18). SEB was obtained by using a unique sequential gradient system. First, an aqueous ammonium acetate to acetonitrile gradient followed by an aqueous trifluoroacetic acid (TFA) wash was used to remove contaminants. A subsequent TFA to acetonitrile-TFA gradient eluted the bound SEB. Further purification was obtained by rechromatography on a cation-exchange column. From 35 to 45% of the SEB in starting filtrates was recovered. Analysis by immunoblotting of samples separated on sodium dodecyl sulfate-polyacrylamide gels indicated that HPLC-purified SEB exhibited immunological and biochemical properties similar to those of the SEB standard. Induction of an emetic response in rhesus monkeys showed that the HPLC-purified toxin also retained biological activity. Images PMID:2745678

  20. Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method.

    PubMed

    Khalikova, Maria A; Šatínský, Dalibor; Solich, Petr; Nováková, Lucie

    2015-05-18

    A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70°C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min(-1). The UV-vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices - Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50-9.09 mg kg(-1) (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg(-1) to 0.60 mg kg(-1) (1.80 mg kg(-1) for Fast Garnet) for standard solution and from 0.25 mg kg(-1) to 1.00 mg kg(-1) (2.50 mg kg(-1) for Fast Garnet, 1.50 mg kg(-1) for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5-107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real

  1. Micro-polarimeter for high performance liquid chromatography

    DOEpatents

    Yeung, Edward E.; Steenhoek, Larry E.; Woodruff, Steven D.; Kuo, Jeng-Chung

    1985-01-01

    A micro-polarimeter interfaced with a system for high performance liquid chromatography, for quantitatively analyzing micro and trace amounts of optically active organic molecules, particularly carbohydrates. A flow cell with a narrow bore is connected to a high performance liquid chromatography system. Thin, low birefringence cell windows cover opposite ends of the bore. A focused and polarized laser beam is directed along the longitudinal axis of the bore as an eluent containing the organic molecules is pumped through the cell. The beam is modulated by air gap Faraday rotators for phase sensitive detection to enhance the signal to noise ratio. An analyzer records the beams's direction of polarization after it passes through the cell. Calibration of the liquid chromatography system allows determination of the quantity of organic molecules present from a determination of the degree to which the polarized beam is rotated when it passes through the eluent.

  2. Determination of caramel colorants' by-products in liquid foods by ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    PubMed

    Goscinny, Séverine; Hanot, Vincent; Trabelsi, Hasna; Van Loco, Joris

    2014-01-01

    2-Methylimidazole, 4-methylimidazole (2-MI and 4-MI), 2-acetyl-4-(1,2,3,4-tetrahydroxybutyl) imidazole (THI) and 5-hydroxymethylfurfural (5-HMF) are neo-formed compounds generated during the manufacture of caramel colours and are transferred to the processed food. These contaminants are known to have a toxicological profile that may pose health risks. Hence, to characterise THI, 2- and 4-MI and 5-HMF levels in liquid foods, an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and sample preparation was divided into two analytical strategies depending on the concentration range expected in the type of foods targeted. For the determination of the imidazole substitutes (THI, 2- and 4-MI), a sample enrichment and clean-up step by strong cation solid-phase extraction was developed. This method is capable of quantifying over a range of 5 ng ml⁻¹ (LOQ) to 500 ng ml⁻¹ with recoveries of 75.4-112.4% and RSDs of 1.5-15%. For determination of 5-HMF, a standard addition method was applied covering the linear range of 0.25-30 µg ml⁻¹ with RSDs from 2.8% (for intraday precision) to 9.2% (for intermediate precision). The validated analytical methods were applied to 28 liquid food samples purchased from local markets. THI was found only in the beer samples at levels up to 141.2 ng ml⁻¹. For 2-MI, non-quantifiable traces were observed for all samples, while 4-MI was observed in all samples with large concentration variations (from < LOQ to 563.9 ng ml⁻¹). 5-HMF was found at expected concentrations, except for a sherry vinegar sample (113 µg ml⁻¹), which required a high level of dilution before following the standard addition protocol.

  3. Simple determination of aflatoxins in rice by ultra-high performance liquid chromatography coupled to chemical post-column derivatization and fluorescence detection.

    PubMed

    Huertas-Pérez, José Fernando; Arroyo-Manzanares, Natalia; Hitzler, Dominik; Castro-Guerrero, Francisco Germán; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2018-04-15

    A fast and simple analytical method was developed and characterized for the determination of aflatoxins (B 1 , B 2 , G 1 and G 2 ) in rice. The procedure is based on a simple solid-liquid extraction without further clean-up, and analysis by ultra-high performance liquid chromatography coupled with fluorescence detection. Fluorescence emission of aflatoxins B 1 and G 1 was enhanced by post-column chemical derivatization using pyridinium bromide perbromide. The analytical method was satisfactorily characterized in white and brown rice. Under optimum conditions, external calibration in solvent could be used for quantification purposes and limits of quantification were below the maximum contents established by the European Union regulation for these contaminants/commodity group combination (0.07-0.14 µg/kg for white rice and 0.20-0.28 µg/kg for brown rice). Recovery studies carried out at three different concentration levels (0.5, 2 and 5 µg/kg) showed values in the range of 84.5-105.3%, and RSDs ≤ 5%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Lech, Rodziewicz; Jolanta, MasŁOwiecka; Anna, Sadowska; Halina, Car

    2017-10-08

    Five thyreostats (TSs), namely tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil, were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert -butyl methyl ether, without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0.2% (v/v) formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5, 10, 15, and 20 μg/L. The accuracy (internal standard corrected) ranged from 92% to 107%, with a repeatability precision (relative standard deviation, RSD) less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits (CCα) and detection capabilities (CCβ) were obtained from a calibration curve and were in the ranges of 3.1-6.1 μg/L and 4.0-7.4 μg/L, respectively. The CCα and CCβ values were below the recommended concentration, which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.

  5. Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Dong, Maofeng; Si, Wenshuai; Wang, Weimin; Bai, Bing; Nie, Dongxia; Song, Weiguo; Zhao, Zhihui; Guo, Yirong; Han, Zheng

    2016-09-01

    Magnetic solid-phase extraction (m-SPE) is a promising sample preparation approach due to its convenience, speed, and simplicity. For the first time, a rapid and reliable m-SPE approach using magnetic multi-walled carbon nanotubes (m-MWCNTs) as the adsorbent was proposed for purification of type A trichothecenes including T-2 toxins (T2), HT-2 toxins (HT-2), diacetoxyscirpenol (DAS), and neosolaniol (NEO) in coix seed. The m-MWCNTs were synthesized by assembling the magnetic nanoparticles (Fe3O4) with MWCNTs by sonication through an aggregation wrap mechanism, and characterized by transmission electron microscope. Several key parameters affecting the performance of the procedure were extensively investigated including extraction solutions, desorption solvents, and m-MWCNT amounts. Under the optimal sample preparation conditions followed by analysis with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), high sensitivity (limit of quantification in the range of 0.3-1.5 μg kg(-1)), good linearity (R (2) > 0.99), satisfactory recovery (73.6-90.6 %), and acceptable precision (≤2.5 %) were obtained. The analytical performance of the developed method has also been successfully evaluated in real coix seed samples. Graphical Abstract Flow chart of determination of type A trichothecenes in coix seed by magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.

  6. Simultaneous determination of mushroom toxins α-amanitin, β-amanitin and muscarine in human urine by solid-phase extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry.

    PubMed

    Tomková, Jana; Ondra, Peter; Válka, Ivo

    2015-06-01

    This paper presents a method for the simultaneous determination of α-amanitin, β-amanitin and muscarine in human urine by solid-phase extraction (SPE) and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. The method can be used for a diagnostics of mushroom poisonings. Different SPE cartridges were tested for sample preparation, namely hydrophilic modified reversed-phase (Oasis HLB) and polymeric weak cation phase (Strata X-CW). The latter gave better results and therefore it was chosen for the subsequent method optimization and partial validation. In the course of validation, limits of detection, linearity, intraday and interday precisions and recoveries were evaluated. The obtained LOD values of α-amanitin and β-amanitin were 1ng/mL and of muscarine 0.09ng/mL. The intraday and interday precisions of human urine spiked with α-amanitin (10ng/mL), β-amanitin (10ng/mL) and muscarine (1ng/mL) ranged from 6% to 10% and from 7% to 13%, respectively. The developed method was proved to be a relevant tool for the simultaneous determination of the studied mushroom toxins in human urine after mushroom poisoning. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Determination of 2-alkylcyclobutanones by combining precolumn derivatization with 1-naphthalenyl hydrazine and ultra-performance liquid chromatography with fluorescence detection.

    PubMed

    Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan

    2016-05-01

    2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.

  8. Wipe selection for the analysis of surface materials containing chemical warfare agent nitrogen mustard degradation products by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2012-12-28

    Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).

  9. An efficient approach to identify different chemical markers between fibrous root and rhizome of Anemarrhena asphodeloides by ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry with multivariate statistical analysis.

    PubMed

    Wang, Fang-Xu; Yuan, Jian-Chao; Kang, Li-Ping; Pang, Xu; Yan, Ren-Yi; Zhao, Yang; Zhang, Jie; Sun, Xin-Guang; Ma, Bai-Ping

    2016-09-10

    An ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry approach coupled with multivariate statistical analysis was established and applied to rapidly distinguish the chemical differences between fibrous root and rhizome of Anemarrhena asphodeloides. The datasets of tR-m/z pairs, ion intensity and sample code were processed by principal component analysis and orthogonal partial least squares discriminant analysis. Chemical markers could be identified based on their exact mass data, fragmentation characteristics, and retention times. And the new compounds among chemical markers could be isolated rapidly guided by the ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry and their definitive structures would be further elucidated by NMR spectra. Using this approach, twenty-four markers were identified on line including nine new saponins and five new steroidal saponins of them were obtained in pure form. The study validated this proposed approach as a suitable method for identification of the chemical differences between various medicinal parts in order to expand medicinal parts and increase the utilization rate of resources. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Ultra-high performance liquid chromatography with fluorescence detection following salting-out assisted liquid-liquid extraction for the analysis of benzimidazole residues in farm fish samples.

    PubMed

    Tejada-Casado, Carmen; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud

    2018-03-30

    Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and flow rate were carefully studied, establishing a gradient mode with a mobile phase consisted of water (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. The separation was performed on a Zorbax Eclipse Plus RRHD C 18 column (50 × 2.1 mm, 1.8 μm), involving a total analysis time lower than 12 min. Salting-out assisted liquid-liquid extraction (SALLE) was applied as sample treatment to different types of farmed fish (trout, sea bream and sea bass). To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt used. Characterization of the method in terms of performance characteristics was carried out, obtaining satisfactory results for the linearity (R 2  ≥ 0.997), repeatability (RSD ≤ 6.1%), reproducibility (RSD ≤ 10.8%) and recoveries (R ≥ 79%; RSD ≤ 7.8%). Detection limits between 0.04-29.9 μg kg -1 were obtained, demonstrating the applicability of this fast, simple and environmentally friendly method. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Ultra-pressure liquid chromatography/tandem mass spectrometry targeted profiling of arachidonic acid and eicosanoids in human colorectal cancer.

    PubMed

    Mal, Mainak; Koh, Poh Koon; Cheah, Peh Yean; Chan, Eric Chun Yong

    2011-03-30

    Cumulative evidence shows that eicosanoids such as prostaglandins, leukotrienes, thromboxanes and hydroxy eicosatetraenoic acids play an important role in associating inflammation with human colorectal cancer (CRC). In this study an ultra-pressure liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the targeted profiling of eight relevant eicosanoids and the major metabolic precursor, arachidonic acid (AA), in human colon. Multiple reaction monitoring (MRM) experiments were performed in negative electrospray ionization mode. The metabolites were separated using a C(18) column consisting of 1.7 µm ethylene-bridged hybrid particles (100 × 2.1 mm i.d.) and gradient elution (50 to 95% of solvent B) with a mobile phase comprising water (0.1% formic acid) [solvent A] and acetonitrile (0.1% formic acid) [solvent B] at a flow rate of 0.4 mL/min. The analysis time for each sample was 5.5 min. Our UPLC/MS/MS method demonstrated satisfactory validation results in terms of selectivity, sensitivity, matrix effect, linearity, extraction efficiency, intra- and inter-day precision, accuracy and autosampler stability. The method was applied for the clinical profiling of matched pairs of cancerous and normal colon mucosae obtained from eight colorectal cancer patients. Endogenous levels of AA and selected eicosanoids such as prostaglandin E(2) (PGE(2)), prostacyclin (PGI(2)) [assayed as its stable hydrolytic product 6-keto-prostaglandin(1α) (6-k PGF(1α))] and 12-hydroxy-5Z,8Z,10E,14Z-eicosatetraenoic acid (12-HETE) were found to be significantly different (p <0.05; paired t-test) between cancerous and normal mucosae. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Evaluating the Antibacterial Properties of Polyacetylene and Glucosinolate Compounds with Further Identification of Their Presence within Various Carrot (Daucus carota) and Broccoli (Brassica oleracea) Cultivars Using High-Performance Liquid Chromatography with a Diode Array Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Analyses.

    PubMed

    Hinds, L; Kenny, O; Hossain, M B; Walsh, D; Sheehy, E; Evans, P; Gaffney, M; Rai, D K

    2017-08-23

    Ongoing consumer concerns over using synthetic additives in foods has strongly influenced efforts worldwide to source suitable natural alternatives. In this study, the antibacterial efficacy of polyacetylene and glucosinolate compounds was evaluated against both Gram positive and Gram negative bacterial strains. Falcarinol [minimum inhibitory concentration (MIC) = 18.8-37.6 μg/mL] demonstrated the best overall antibacterial activity, while sinigrin (MIC = 46.9-62.5 μg/mL) was the most active glucosinolate compound. High-performance liquid chromatography with a diode array detector analysis showed falcarinol [85.13-244.85 μg/g of dry weight (DW)] to be the most abundant polyacetylene within six of the eight carrot (Daucus carota) cultivars investigated. Meanwhile, sinigrin (100.2-244.3 μg/g of DW) was the most abundant glucosinolate present within the majority of broccoli (Brassica oleracea) cultivars investigated using ultra performance liquid chromatography-tandem mass spectrometry analysis. The high abundance of both falcarinol and sinigrin within these respective species suggests that they could serve as potential sources of natural antibacterial agents for use as such in food products.

  13. Rapid determination of the various native forms of vitamin B6 and B2 in cow's milk using ultra-high performance liquid chromatography.

    PubMed

    Schmidt, A; Schreiner, M G; Mayer, H K

    2017-06-02

    As the formation of pyridoxal phosphate, the active cofactor of vitamin B 6 , is dependent on riboflavin 5-phosphate, we propose a fast and simple ultra-high performance liquid chromatography method for the simultaneous determination of the native B 6 vitamers pyridoxal, pyridoxine, pyridoxamine, their mono phosphorus esters and 4-pyridoxic acid as well as vitamin B 2 as riboflavin and its phosphorus ester riboflavin 5-phosphate in milk. Separation was achieved under 6.0min by reversed-phase and pH gradient elution. Sample preparation was optimized regarding various acids and pH levels. Changes in those parameters led to significant deviations of sample matrix breakdown efficiency. The optimized method was then validated regarding specificity, accuracy, precision, linearity, range, detection and quantification limits. As the method performed satisfactory, is was used to study commercial liquid cow's milk (n=31), regarding effects of the employed preservation technique (pasteurization, extended shelf-life, ultra-high temperature) on the composition and content of B 6 and B 2 vitamers. In cow's milk, vitamin B 6 mostly consists of pyridoxal and its phosphate ester, with pyridoxal phosphate being the bulk component. The catabolite of the vitamin B 6 metabolism, 4-pyridoxic acid was present in significant amounts in all studied samples, with up to 2.69μmolL -1 . Vitamin B 2 was present as riboflavin and its phosphate ester up to 12.86μmolL -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Counter-current chromatography with off-line detection by ultra high performance liquid chromatography/high resolution mass spectrometry in the study of the phenolic profile of Lippia origanoides.

    PubMed

    Leitão, Suzana Guimaraes; Leitão, Gilda Guimarães; Vicco, Douglas K T; Pereira, João Paulo Barreto; de Morais Simão, Gustavo; Oliveira, Danilo R; Celano, Rita; Campone, Luca; Piccinelli, Anna Lisa; Rastrelli, Luca

    2017-10-20

    Lippia origanoides (Verbenaceae) is an important Brazilian medicinal plant, also used for culinary purposes. Most chemical studies with this plant have been focused on its volatile composition. In this work, we combined High-Speed Counter-current Chromatography (HSCCC) and High Performance Liquid Chromatography coupled to Ultra Violet detection and High Resolution Mass Spectrometry (HPLC-UV-HRMS n ) methodologies to access the non-volatile chemical composition of L. origanoides. The crude ethanol extract of L. origanoides (LOEF) was first analyzed by HPLC-UV-HRMS n and allowed the identification of 7 major compounds. Among them, eriodictyol, naringenin and pinocembrin, were determined and are phytochemical markers of this plant. However, owing to the complexity of this plant matrix, LOEF was fractionated by HSCCC (hexane-ethanol-water, 4:3:1) as a tool for preparative pre-purification, affording a flavonoid-rich fraction. A column screening with the chromatographic stationary phases ZIC-HILIC, monolithic and particulate RP18 was performed. The best column separation was achieved with a Purospher STAR RP18e, which was used for HPLC-DAD-HRMS n studies. By this approach 12 compounds were further identified in addition to the major ones identified in the raw extract. Two of them, 6,8-di-C-hexosyl-luteolin and 6,8-di-C-glucosyl-apigenin, are being reported for the first time in the family Verbenaceae. This work shows the integration of HSCCC as a preparative tool for the fractionation and purification of natural products from a complex plant extract with other analytical techniques, with the purpose of showing each technique's potential. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Ultra-high-performance liquid chromatography-Time-of-flight high resolution mass spectrometry to quantify acidic drugs in wastewater.

    PubMed

    Becerra-Herrera, Mercedes; Honda, Luis; Richter, Pablo

    2015-12-04

    A novel analytical approach involving an improved rotating-disk sorptive extraction (RDSE) procedure and ultra-high-performance liquid chromatography (UHPLC) coupled to an ultraspray electrospray ionization source (UESI) and time-of-flight mass spectrometry (TOF/MS), in trap mode, was developed to identify and quantify four non-steroidal anti-inflammatory drugs (NSAIDs) (naproxen, ibuprofen, ketoprofen and diclofenac) and two anti-cholesterol drugs (ACDs) (clofibric acid and gemfibrozil) that are widely used and typically found in water samples. The method reduced the amount of both sample and reagents used and also the time required for the whole analysis, resulting in a reliable and green analytical strategy. The analytical eco-scale was calculated, showing that this methodology is an excellent green analysis, increasing its ecological worth. The detection limits (LOD) and precision (%RSD) were lower than 90ng/L and 10%, respectively. Matrix effects and recoveries were studied using samples from the influent of a wastewater treatment plant (WWTP). All the compounds exhibited suppression of their signals due to matrix effects, and the recoveries were approximately 100%. The applicability and reliability of this methodology were confirmed through the analysis of influent and effluent samples from a WWTP in Santiago, Chile, obtaining concentrations ranging from 1.1 to 20.5μg/L and from 0.5 to 8.6μg/L, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. High Performance Liquid Chromatography

    NASA Astrophysics Data System (ADS)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  17. Comprehensive identification of bioactive compounds of avocado peel by liquid chromatography coupled to ultra-high-definition accurate-mass Q-TOF.

    PubMed

    Figueroa, Jorge G; Borrás-Linares, Isabel; Lozano-Sánchez, Jesús; Segura-Carretero, Antonio

    2018-04-15

    Industrially the avocado pulp is exploited principally as oil and paste, generating a huge quantity of peel and seed as by-products. Avocado peel is a promising inexpensive candidate for recovery phenolic compounds. The aim of this work was to identify the bioactive compounds present in an extract of avocado peel obtained by a green extraction technique. Accelerated solvent extraction was performed using water and ethanol as extraction solvents. Liquid chromatography coupled to ultra-high-definition accurate-mass spectrometry was used in order to identify the bioactive compounds. A total of sixty-one compounds belonging to eleven families were identified. Procyanidins, flavonols, hydroxybenzoic and hydroxycinnamic acids were the most common compounds. A sum of thirty-five compounds has been identified here for the first time in avocado peel. These results confirm the potential of avocado peel as a source of bioactive ingredients for its use in the food, cosmetic or pharmaceutical sector. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation.

    PubMed

    Lestremau, François; Wu, Di; Szücs, Roman

    2010-07-23

    The present study focuses on the evaluation of 1.0 mm i.d. (internal diameter) columns on a commercial Ultra-High Pressure system. These systems have been developed specifically to operate columns with small volumes, typically 2.1 mm i.d., by reducing extra-column volume dispersion. The use of columns with smaller i.d. results in a reduced solvent consumption and required sample volume. The evaluation of the columns was carried out with samples containing neutral and pharmaceutical compounds. In isocratic mode, the extra-column volume produced additional band broadening leading to poor performances compared to equivalent 2.1 mm i.d. columns. By increasing the length of the column, the influence of the extra-column bandspreading could be reduced and 75,000 plates were obtained when four columns were coupled. In gradient mode, the effect of the extra-column contribution on efficiency was limited and about 80% of the performance of the 2.1 mm i.d. columns was obtained. Optimum conditions in gradient mode were further investigated by changing flow rate, gradient time and column length. A different approach of the calculation of peak capacity was also considered for the comparison of the influence of these different parameters. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  19. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography.

    PubMed

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.

  20. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography

    PubMed Central

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    Objective: In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. Materials and Methods: In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. Results: HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. Conclusion: The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. SUMMARY Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida PMID:26941534

  1. Determination of perfluorinated chemicals in food and drinking water using high-flow solid-phase extraction and ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Chang, Ying-Chia; Chen, Wen-Ling; Bai, Fang-Yu; Chen, Pau-Chung; Wang, Gen-Shuh; Chen, Chia-Yang

    2012-01-01

    For this study, we developed methods of determining ten perfluorinated chemicals in drinking water, milk, fish, beef, and pig liver using high-flow automated solid-phase extraction (SPE) and ultra-high performance liquid chromatography/tandem mass spectrometry. The analytes were separated on a core-shell Kinetex C18 column. The mobile phase was composed of methanol and 10-mM N-methylmorpholine. Milk was digested with 0.5 N potassium hydroxide in Milli-Q water, and was extracted with an Atlantic HLB disk to perform automated SPE at a flow rate ranged from 70 to 86 mL/min. Drinking water was directly extracted by the SPE. Solid food samples were digested in alkaline methanol and their supernatants were diluted and also processed by SPE. The disks were washed with 40% methanol/60% water and then eluted with 0.1% ammonium hydroxide in methanol. Suppression of signal intensity of most analytes by matrixes was lower than 50%; it was generally lower in fish and drinking water but higher in liver. Most quantitative biases and relative standard deviations were lower than 15%. The limits of detection for most analytes were sub-nanograms per liter for drinking water and sub-nanograms per gram for solid food samples. This method greatly shortened the time and labor needed for digestion, SPE, and liquid chromatography. This method has been applied to analyze 14 types of food samples. Perfluorooctanoic acid was found to be the highest among the analytes (median at 3.2-64 ng/g wet weight), followed by perfluorodecanoic acid (0.7-25 ng/g) and perfluorododecanoic acid (0.6-15 ng/g).

  2. Distribution of C16:0, C18:0, C24:1, and C24:0 sulfatides in central nervous system lipid rafts by quantitative ultra-high-pressure liquid chromatography tandem mass spectrometry.

    PubMed

    Moyano, Ana Lis; Li, Guannan; Lopez-Rosas, Aurora; Månsson, Jan-Eric; van Breemen, Richard B; Givogri, Maria Irene

    2014-12-15

    Sulfated galactosylceramides (sulfatides) are glycosphingolipids associated with cholesterol- and sphingolipid-enriched membrane microdomains (lipid rafts) and are highly expressed in brain tissue. Although it is known that sulfatide species show heterogeneity in their fatty acid acyl group composition throughout brain development, their lipid raft distribution and biological relevance is poorly understood. We validated a fast and sensitive ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method to measure developmentally regulated sulfatide species (C16:0, C18:0, C24:1, and C24:0) in central nervous system (CNS) lipid rafts isolated without using detergent. Our UHPLC-MS/MS assay showed good accuracy and precision with a linear range of 5 to 1,000 nM for C18:0 and C24:1 sulfatides and 10 to 1,000 nM for C16:0 and C24:0 sulfatides. We applied this quantitative analysis to detergent-free lipid rafts isolated from wild-type mice and arylsulfatase A-deficient (ASA knockout) mice that accumulate sulfatides. All four sulfatide species were more abundant in raft membranes than in non-raft membranes, with a significant increase in lipid rafts isolated from ASA knockout mice. This is the first description of an analytical method to study these sulfatide species in raft and non-raft membranes and has the potential to be applied to preparations from other tissues. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. A validated ultra high-pressure liquid chromatography method for separation of candesartan cilexetil impurities and its degradents in drug product

    PubMed Central

    Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish

    2012-01-01

    Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475

  4. The simple determination method for anthocyanidin aglycones in fruits using ultra-high-performance liquid chromatography.

    PubMed

    Shim, You-Shin; Yoon, Won-Jin; Kim, Dong-Man; Watanabe, Masaki; Park, Hyun-Jin; Jang, Hae Won; Lee, Jangho; Ha, Jaeho

    2015-01-01

    The simple determination method for anthocyanidin aglycones in fruits using ultra-high-performance liquid chromatography (UHPLC) coupled with the heating-block acidic hydrolysis method was validated through the precision, accuracy and linearity. The UHPLC separation was performed on a reversed-phase C18 column (particle size 2 μm, i.d. 2 mm, length 100 mm) with a photodiode-array detector. The limits of detection and quantification of the UHPLC analyses were 0.09 and 0.29 mg/kg for delphinidin, 0.08 and 0.24 mg/kg for cyanidin, 0.09 and 0.26 mg/kg for petunidin, 0.14 and 0.42 mg/kg for pelargonidin, 0.16 and 0.48 mg/kg for peonidin and 0.30 and 0.91 mg/kg for malvidin, respectively. The intra- and inter-day precisions of individual anthocyanidin aglycones were <10.3%. All calibration curves exhibited good linearity (r = 0.999) within the tested ranges. The total run time of UHPLC was 8 min. The simple preparation method with UHPLC detection in this study presented herein significantly improved the speed and the simplicity for preparation step of delphinidin, cyanidin, petunidin, pelargonidin, peonidin and malvidin in fruits. Especially, the UHPLC detection exhibited good resolution in spite of shorter run time about four times than conventional HPLC detection. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Determination of colistin in animal tissues, egg, milk, and feed by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Fu, Qin; Li, Xiaowei; Zheng, Kangni; Ke, Yuebin; Wang, Yingyu; Wang, Lina; Yu, Fugen; Xia, Xi

    2018-05-15

    A confirmatory method for the determination of colistin in animal tissues, egg, milk, and feed was developed and validated. Colistin A and colistin B were extracted from samples with the mixture of 10% trichloroacetic acid-acetonitrile and isolated with mixed-mode weak cation exchange cartridge. Analytes were separated from matrix components using ultra-high performance liquid chromatography, and detected with electrospray ionization on a triple quadrupole mass spectrometer. Mean recoveries ranged from 78.0% to 115.6% with intra-day and inter-day relative standard deviation lower than 8.4% and 12.4%, respectively. The quantitation limits for different matrices were between 5 and 30 μg/kg, which was satisfactory for surveillance monitoring. The developed method was applied to the analysis of real samples collected from different provinces of China, and 19 out of 348 samples were found to be contaminated, with the highest concentration of approximately 12,000 μg/kg colistin A and 10,000 μg/kg colistin B in feed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Development and validation of an ultra-performance convergence chromatography method for the quality control of Angelica gigas Nakai.

    PubMed

    Kim, Hyo Seon; Chun, Jin Mi; Kwon, Bo-In; Lee, A-Reum; Kim, Ho Kyoung; Lee, A Yeong

    2016-10-01

    Ultra-performance convergence chromatography, which integrates the advantages of supercritical fluid chromatography and ultra high performance liquid chromatography technologies, is an environmentally friendly analytical method that uses dramatically reduced amounts of organic solvents. An ultra-performance convergence chromatography method was developed and validated for the quantification of decursinol angelate and decursin in Angelica gigas using a CSH Fluoro-Phenyl column (2.1 mm × 150 mm, 1.7 μm) with a run time of 4 min. The method had an improved resolution and a shorter analysis time in comparison to the conventional high-performance liquid chromatography method. This method was validated in terms of linearity, precision, and accuracy. The limits of detection were 0.005 and 0.004 μg/mL for decursinol angelate and decursin, respectively, while the limits of quantitation were 0.014 and 0.012 μg/mL, respectively. The two components showed good regression (correlation coefficient (r 2 ) > 0.999), excellent precision (RSD < 2.28%), and acceptable recoveries (99.75-102.62%). The proposed method can be used to efficiently separate, characterize, and quantify decursinol angelate and decursin in Angelica gigas and its related medicinal materials or preparations, with the advantages of a shorter analysis time, greater sensitivity, and better environmental compatibility. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Rapid qualitative and quantitative analysis of proanthocyanidin oligomers and polymers by ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS)

    USDA-ARS?s Scientific Manuscript database

    We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...

  8. (PRESENT AT NCCU) ANALYSIS OF SELECTED PYRETHROID PESTICIDES USING REVERSE PHASE HIGH LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these pyre...

  9. Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Peng, Xianzhi; Jin, Jiabin; Wang, Chunwei; Ou, Weihui; Tang, Caiming

    2015-03-06

    A sensitive and reliable method was developed for multi-target determination of 13 most widely used organic ultraviolet (UV) absorbents (including UV filters and UV stabilizers) in aquatic organism tissues. The organic UV absorbents were extracted using ultrasonic-assisted extraction, purified via gel permeation chromatography coupled with silica gel column chromatography, and determined by ultra-high performance liquid chromatography-tandem mass spectrometry. Recoveries of the UV absorbents from organism tissues mostly ranged from 70% to 120% from fish filet with satisfactory reproducibility. Method quantification limits were 0.003-1.0ngg(-1) dry weight (dw) except for 2-ethylhexyl 4-methoxycinnamate. This method has been applied to analysis of the UV absorbents in wild and farmed aquatic organisms collected from the Pearl River Estuary, South China. 2-Hydroxy-4-methoxybenzophenone and UV-P were frequently detected in both wild and farmed marine organisms at low ngg(-1)dw. 3-(4-Methylbenzylidene)camphor and most of the benzotriazole UV stabilizers were also frequently detected in maricultured fish. Octocrylene and 2-ethylhexyl 4-methoxycinnamate were not detected in any sample. This work lays basis for in-depth study about bioaccumulation and biomagnification of the UV absorbents in marine environment. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Validation of a method for simultaneous determination of nitroimidazoles, benzimidazoles and chloramphenicols in swine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong

    2013-05-31

    This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Quantitation of phlorizin and phloretin using an ultra high performance liquid chromatography-electrospray ionization tandem mass spectrometric method.

    PubMed

    Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei

    2014-06-01

    A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Multi-residue determination of 210 drugs in pork by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Yin, Zhiqiang; Chai, Tingting; Mu, Pengqian; Xu, Nana; Song, Yue; Wang, Xinlu; Jia, Qi; Qiu, Jing

    2016-09-09

    This paper presents a multi-residue analytical method for 210 drugs in pork using ultra-high-performance liquid chromatography-Q-Trap tandem mass spectrometry (UPLC-MS/MS) within 20min via positive ESI in scheduled multi-reaction monitoring (MRM) mode. The 210 drugs, belonging to 21 different chemical classes, included macrolides, sulfonamides, tetracyclines, β-lactams, β-agonists, aminoglycosides, antiviral drugs, glycosides, phenothiazine, protein anabolic hormones, non-steroidal anti-inflammatory drugs (NSAIDs), quinolones, antifungal drugs, corticosteroids, imidazoles, piperidines, piperazidines, insecticides, amides, alkaloids and others. A rapid and simple preparation method was applied to process the animal tissues, including solvent extraction with an acetonitrile/water mixture (80/20, v/v), defatting and clean-up processes. The recoveries ranged from 52% to 130% with relative standard deviations (RSDs)<20% for spiked concentrations of 10, 50 and 250μg/kg. More than 90% of the analytes achieved low limits of quantification (LOQs)<10μg/kg. The decision limit (CCα), detection capability (CCβ) values were in the range of 2-502μg/kg and 4-505μg/kg, respectively. This method is significant for food safety monitoring and controlling veterinary drug use. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Determination and fingerprint analysis of steroidal saponins in roots of Liriope muscari (Decne.) L. H. Bailey by ultra high performance liquid chromatography coupled with ion trap time-of-flight mass spectrometry.

    PubMed

    Li, Yong-Wei; Qi, Jin; Wen-Zhang; Zhou, Shui-Ping; Yan-Wu; Yu, Bo-Yang

    2014-07-01

    Liriope muscari (Decne.) L. H. Bailey is a well-known traditional Chinese medicine used for treating cough and insomnia. There are few reports on the quality evaluation of this herb partly because the major steroid saponins are not readily identified by UV detectors and are not easily isolated due to the existence of many similar isomers. In this study, a qualitative and quantitative method was developed to analyze the major components in L. muscari (Decne.) L. H. Bailey roots. Sixteen components were deduced and identified primarily by the information obtained from ultra high performance liquid chromatography with ion-trap time-of-flight mass spectrometry. The method demonstrated the desired specificity, linearity, stability, precision, and accuracy for simultaneous determination of 15 constituents (13 steroidal glycosides, 25(R)-ruscogenin, and pentylbenzoate) in 26 samples from different origins. The fingerprint was established, and the evaluation was achieved using similarity analysis and principal component analysis of 15 fingerprint peaks from 26 samples by ultra high performance liquid chromatography. The results from similarity analysis were consistent with those of principal component analysis. All results suggest that the established method could be applied effectively to the determination of multi-ingredients and fingerprint analysis of steroid saponins for quality assessment and control of L. muscari (Decne.) L. H. Bailey. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Putative identification of new p-coumaroyl glycoside flavonoids in grape by ultra-high performance liquid chromatography/high-resolution mass spectrometry.

    PubMed

    Panighel, Annarita; De Rosso, Mirko; Dalla Vedova, Antonio; Flamini, Riccardo

    2015-02-28

    Grape polyphenols are antioxidant compounds, markers in vine chemotaxonomy, and involved in color stabilization of red wines. Sugar acylation usually confers higher stability on glycoside derivatives and this effect is enhanced by an aromatic substituent such as p-coumaric acid. Until now, only p-coumaroyl anthocyanins have been found in grape. A method of 'suspect screening analysis' by ultra-high-performance liquid chromatography/high-resolution mass spectrometry (UHPLC/QTOFMS) has recently been developed to study grape metabolomics. In the present study, this approach was used to identify new polyphenols in grape by accurate mass measurement, MS/MS fragmentation, and study of correlations between fragments observed and putative structures. Three putative p-coumaroyl flavonoids were identified in Raboso Piave grape extract: a dihydrokaempferide-3-O-p-coumaroylhexoside-like flavanone, isorhamnetin-3-O-p-coumaroylglucoside, and a chrysoeriol-p-coumaroylhexoside-like flavone. Accurate MS provided structural characterization of functional groups, and literature data indicates their probable position in the molecule. A fragmentation scheme is proposed for each compound. Compounds were identified by overlapping various analytical methods according to recommendations in the MS-based metabolomics literature. Stereochemistry and the definitive position of substituents in the molecule can only be confirmed by isolation and characterization or synthesis of each compound. These findings suggest addressing research of acylated polyphenol glycosides to other grape varieties. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Rapid and sensitive ultra-high-pressure liquid chromatography-tandem mass spectrometry analysis of the novel anticancer agent PR-104 and its major metabolites in human plasma: Application to a pharmacokinetic study.

    PubMed

    Gu, Yongchuan; Wilson, William R

    2009-10-01

    PR-104 is a dinitrobenzamide mustard currently in clinical trial as a hypoxia-activated prodrug. It is converted systemically to the corresponding alcohol, PR-104A, which is activated by nitroreduction to the hydroxylamine (PR-104H) and amine (PR-104M). PR-104A is also metabolised to the O-glucuronide (PR-104G), and by oxidative debromoethylation to the semi-mustard PR-104S. We now report a validated ultra-high-pressure liquid chromatography and tandem mass spectrometry (UHPLC-MS/MS) method for the determination of these metabolites in human plasma. Plasma proteins were precipitated with acidified methanol and the supernatant diluted into water. Aliquots were analysed by UHPLC-MS/MS using a Zorbax Eclipse XDB-C18 Rapid Resolution HT (50mmx2.1mm, 1.8microm) column and gradient of acetonitrile and 0.01% formic acid with a 6min run time. The method had a linear range of 0.1-50microM for PR-104, PR-104A and PR-104G, 0.05-5microM for PR-104H, 0.025-2.5microM for PR-104M and 0.01-1microM for PR-104S. The intra-day and inter-day precision and accuracy were within 14%. The extraction recovery of all analytes was over 87%. The validated method was illustrated by using it to study the pharmacokinetics of PR-104 and its metabolites in a human patient.

  16. A green ionic liquid-based vortex-forced MSPD method for the simultaneous determination of 5-HMF and iridoid glycosides from Fructus Corni by ultra-high performance liquid chromatography.

    PubMed

    Du, Kunze; Li, Jin; Bai, Yun; An, Mingrui; Gao, Xiu-Mei; Chang, Yan-Xu

    2018-04-01

    A simple and green ionic liquid-based vortex-forced matrix solid phase dispersion (IL-VFMSPD) method was presented to simultaneously extract 5-hydroxymethyl furfurol (5-HMF) and iridoid glycosides in Fructus Corni by ultra-high performance liquid chromatography. Ionic liquid was used as a green elution reagent in vortex-forced MSPD process. A few parameters such as the type of ionic liquid, the type of sorbent, ratio of sample to sorbent, the concentration and volume of ionic liquid, grinding time and vortex time, were investigated in detail and an orthogonal design experiment was introduced to confirm the best conditions in this procedure. With the final optimized method, the recoveries of the target compounds in Fructus Corni were in the range of 95.2-103% (RSD<5.0%) and the method displayed a good linearity within the range of 0.8-200 μg mL -1 for morroniside, sweroside, loganin, cornuside and 1.2-300 μg mL -1 for 5-HMF. The limits of detection ranged from 0.02 to 0.08 μg mL -1 for all compounds. The results showed that the newly established method was efficiently applied to extract and determine iridoid glycosides and 5-HMF for quality control of Fructus Corni. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. An improved method for retrospective quantification of sulfur mustard exposure by detection of its albumin adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, ChangCai; Liang, LongHui; Xiang, Yu; Yu, HuiLan; Zhou, ShiKun; Xi, HaiLing; Liu, ShiLei; Liu, JingQuan

    2015-09-01

    Sulfur mustard (HD) adduct to human serum albumin (ALB) at Cys-34 residue has become an important and long-term retrospective biomarker of HD exposure. Here, a novel, sensitive, and convenient approach for retrospective quantification of HD concentration exposed to plasma was established by detection of the HD-ALB adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with a novel non-isotope internal standard (IS). The HD-ALB adduct was isolated from HD-exposed plasma with blue Sepharose. The adduct was digested with proteinase K to form sulfur-hydroxyethylthioethyl ([S-HETE])-Cys-Pro-Phe tripeptide biomarker. The tripeptide adduct could be directly analyzed by UHPLC-MS/MS without an additional solid phase extraction (SPE), which was considered as a critical procedure in previous methods. The easily available 2-chloroethyl ethylsulfide (2-CEES) as HD surrogate was first reported to be used as IS in place of traditional d8-HD for quantification of HD exposure. Furthermore, 2-CEES was also confirmed to be a good IS alternative for quantification of HD exposure by investigation of product ion spectra for their corresponding tripeptide adducts which exhibited identical MS/MS fragmentation behaviors. The method was found to be linear between 1.00 and 250 ng•mL(-1) HD exposure (R(2)>0.9989) with precision of <4.50% relative standard deviation (%RSD), accuracy range between 96.5% and 114%, and a calculated limit of detection (LOD) of 0.532 ng•mL(-1). The lowest reportable limit (LRL) is 1.00 ng•mL(-1), over seven times lower than that of the previous method. The entire method required only 0.1 mL of plasma sample and took under 7 h without special sample preparation equipment. It is proven to be a sensitive, simple, and rugged method, which is easily applied in international laboratories to improve the capabilities for the analysis of biomedical samples related to verification of the Chemical Weapon Convention (CWC).

  18. High-performance liquid chromatography of oligoguanylates at high pH

    NASA Technical Reports Server (NTRS)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  19. Surface-bonded ionic liquid stationary phases in high-performance liquid chromatography--a review.

    PubMed

    Pino, Verónica; Afonso, Ana M

    2012-02-10

    Ionic liquids (ILs) are a class of ionic, nonmolecular solvents which remain in liquid state at temperatures below 100°C. ILs possess a variety of properties including low to negligible vapor pressure, high thermal stability, miscibility with water or a variety of organic solvents, and variable viscosity. IL-modified silica as novel high-performance liquid chromatography (HPLC) stationary phases have attracted considerable attention for their differential behavior and low free-silanol activity. Indeed, around 21 surface-confined ionic liquids (SCIL) stationary phases have been developed in the last six years. Their chromatographic behavior has been studied, and, despite the presence of a positive charge on the stationary phase, they showed considerable promise for the separation of neutral solutes (not only basic analytes), when operated in reversed phase mode. This aspect points to the potential for truly multimodal stationary phases. This review attempts to summarize the state-of-the-art about SCIL phases including their preparation, chromatographic behavior, and analytical performance. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. High-Performance Liquid Chromatography-Mass Spectrometry.

    ERIC Educational Resources Information Center

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  1. Phytochemical composition of fractions isolated from ten Salvia species by supercritical carbon dioxide and pressurized liquid extraction methods.

    PubMed

    Šulniūtė, Vaida; Pukalskas, Audrius; Venskutonis, Petras Rimantas

    2017-06-01

    Ten Salvia species, S. amplexicaulis, S. austriaca, S. forsskaolii S. glutinosa, S. nemorosa, S. officinalis, S. pratensis, S. sclarea, S. stepposa and S. verticillata were fractionated using supercritical carbon dioxide and pressurized liquid (ethanol and water) extractions. Fifteen phytochemicals were identified using commercial standards (some other compounds were identified tentatively), 11 of them were quantified by ultra high pressure chromatography (UPLC) with quadruple and time-of-flight mass spectrometry (Q/TOF, TQ-S). Lipophilic CO 2 extracts were rich in tocopherols (2.36-10.07mg/g), while rosmarinic acid was dominating compound (up to 30mg/g) in ethanolic extracts. Apigenin-7-O-β-d-glucuronide, caffeic and carnosic acids were quantitatively important phytochemicals in the majority other Salvia spp. Antioxidatively active constituents were determined by using on-line high-performance liquid chromatography (HPLC) analysis combined with 2,2'-diphenyl-1-picrylhydrazyl (DPPH) assay (HPLC-DPPH). Development of high pressure isolation process and comprehensive characterisation of phytochemicals in Salvia spp. may serve for their wider applications in functional foods and nutraceuticals. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Determination of steroid hormones in fish tissues by microwave-assisted extraction coupled to ultra-high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Guedes-Alonso, Rayco; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan

    2017-12-15

    Steroid hormones produce adverse effects on biota as well as bioaccumulation in fish and seafood, making it necessary to develop methodologies to evaluate these compounds in samples related to the food chain. This work presents an analytical method for evaluating 15 steroid hormones in fish tissue. It is based on microwave-assisted extraction and solid-phase extraction coupled to ultra-high-performance liquid chromatography tandem mass spectrometry (MAE-SPE-UHPLC-MS/MS). The proposed method shows appropriate detection limits (0.14-49.0ngg -1 ), recoveries in the range of 50% and good repeatability. After optimization, the method was applied to different tissues from two small fishes of the Canary Islands that constitute an important level of the food web (Boops boops and Sphoeroides marmoratus) and were exposed to the outfall of the Las Palmas de Gran Canaria wastewater treatment plant. The concentrations of eight detected compounds ranged from below the quantification limits to 3.95μgg -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. One-step separation and purification of three lignans and one flavonol from Sinopodophyllum emodi by medium-pressure liquid chromatography and high-speed counter-current chromatography.

    PubMed

    Wang, Ping; Liu, Yongling; Chen, Tao; Xu, Wenhua; You, Jinmao; Liu, Yongjun; Li, Yulin

    2013-01-01

    Lignans and flavonols are the primary constituents of Sinopodophyllum emodi and have been used as cathartic, anthelmintic, chemotherapeutic and anti-hypertensive compounds. Although these compounds have been isolated, there have been no reports on the separation of 4'-demethyl podophyllotoxin, podophyllotoxin, deoxypodophyllotoxin and kaempferol in one step by medium-pressure liquid chromatography (MPLC) and high-speed counter-current chromatography (HSCCC). Development of an efficient method for the preparative separation and purification of three lignans and one flavonol from S. emodi. The precipitate of crude extracts was first separated by MPLC into four parts, numbered GJ-1, GJ-2, GJ-3 and GJ-4. GJ-1 was separated and purified by HSCCC using a solvent system composed of n-hexane:ethyl acetate:methanol:water (1.75:1.5:1:0.75, v/v/v/v). The purities of the target compounds were assessed using high-performance liquid chromatography (HPLC) and chemical structures were identified by (1) H-NMR and (13) C-NMR. The HSCCC and MPLC methods were successfully used for the preparative separation and purification of 4'-demethyl podophyllotoxin (8.5 mg, 92.4%), podophyllotoxin (40.1 mg, 92.1%), deoxypodophyllotoxin (4.6 mg, 98.1%), and kaempferol (1.6 mg, 96.7%) from a 100 mg sample. Three lignans (4'-demethyl podophyllotoxin, podophyllotoxin, deoxypodophyllotoxin) and one flavonol (kaempferol) were successfully isolated by HSCCC and MPLC in one step. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  5. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    PubMed

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Assay of free and glycine- and taurine-conjugated bile acids in serum by high-pressure liquid chromatography by using post-column reaction after group separation.

    PubMed Central

    Onishi, S; Itoh, S; Ishida, Y

    1982-01-01

    An accurate and sensitive method that involves the group separations of serum bile acids (i.e. free and glycine- and taurine-conjugated bile acid fractions) by ion-exchange chromatography on piperidinohydroxypropyl-Sephadex LH-20 is described. Each group was then analysed by high-pressure liquid chromatography by using the post-column reaction technique with immobilized 3 alpha-hydroxy steroid dehydrogenase. The bile acid patterns in the umbilical venous serum samples were analysed by this method. Taurochenodeoxycholate predominated in the umbilical blood. PMID:6956336

  7. Very high pressure liquid chromatography using core-shell particles: quantitative analysis of fast gradient separations without post-run times.

    PubMed

    Stankovich, Joseph J; Gritti, Fabrice; Stevenson, Paul G; Beaver, Lois A; Guiochon, Georges

    2014-01-17

    Five methods for controlling the mobile phase flow rate for gradient elution analyses using very high pressure liquid chromatography (VHPLC) were tested to determine thermal stability of the column during rapid gradient separations. To obtain rapid separations, instruments are operated at high flow rates and high inlet pressure leading to uneven thermal effects across columns and additional time needed to restore thermal equilibrium between successive analyses. The purpose of this study is to investigate means to minimize thermal instability and obtain reliable results by measuring the reproducibility of the results of six replicate gradient separations of a nine component RPLC standard mixture under various experimental conditions with no post-run times. Gradient separations under different conditions were performed: constant flow rates, two sets of constant pressure operation, programmed flow constant pressure operation, and conditions which theoretically should yield a constant net heat loss at the column's wall. The results show that using constant flow rates, programmed flow constant pressures, and constant heat loss at the column's wall all provide reproducible separations. However, performing separations using a high constant pressure with programmed flow reduces the analysis time by 16% compared to constant flow rate methods. For the constant flow rate, programmed flow constant pressure, and constant wall heat experiments no equilibration time (post-run time) was required to obtain highly reproducible data. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development of an ultra-high-pressure liquid chromatography-tandem mass spectrometry multi-residue sulfonamide method and its application to water, manure slurry, and soils from swine rearing facilities.

    PubMed

    Shelver, Weilin L; Hakk, Heldur; Larsen, Gerald L; DeSutter, Thomas M; Casey, Francis X M

    2010-02-19

    An analytical method was developed using ultra-high-pressure liquid chromatography-triple quadrupole-tandem mass spectrometry (UHPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in 6 min. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryover was observed even after high analyte concentrations. The instrumental detection limit based on signal-to-noise ratio (S/N)>3, was below 1 pg/microL (5 pg on column) for all SAs except sulfachloropyridazine. Surface water, ground water, soil, and slurry manure contained in storage ponds in and around swine [Sus scrofa domesticus] rearing facilities were analyzed. Sample cleanup for ground water and surface water included using solid phase extraction (SPE) using Oasis hydrophilic-lipophilic balance (HLB) cartridges. The soil and slurry manure required tandem strong anion exchange (SAX) and HLB solid phase extraction cartridges for sample cleanup. With few exceptions, the recoveries ranged from 60 to 100% for all matrices. The minimum detectable levels were below 2.0 ng/L for water, 30 ng/L for slurry manure, and 45 ng/kg for soil except for sulfachloropyridazine. The coefficient of variation (CV) was within 20% for most of the compounds analyzed. Using this method, sulfamethazine concentrations of 2250-5060 ng/L, sulfamethoxazole concentrations of 108-1.47 x 10(6)ng/L, and sulfathiazole concentrations of 785-1700 ng/L were found in the slurry manure. Sulfadimethoxine (2.0-32 ng/L), sulfamethazine (2.0-5.1 ng/L), and sulfamethoxazole (20.5-43.0 ng/L) were found in surface water and ground water. In top soil (0-15 cm), sulfamethazine ranged 34.5-663 ng/kg dry weight in those locations that received slurry manure as a nutrient; no SAs were found in the soil depths between 46 and 61 cm. The speed makes the method practical for medium to high throughput applications. The sensitivity and positive analyte identification make the method suitable for the demanding requirements for

  9. Metabolomic approaches for orange origin discrimination by ultra-high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry.

    PubMed

    Díaz, Ramon; Pozo, Oscar J; Sancho, Juan V; Hernández, Félix

    2014-08-15

    In this work, hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) coupled to ultra high performance liquid chromatography (UHPLC) has been used for biomarkers identification for correct authentication of Valencia (Spain) oranges. Differentiation from foreign Argentinean, Brazilian and South African oranges has been carried out using XCMS application and multivariate analysis to UHPLC-(Q)TOF MS data acquired in both, positive and negative ionisation modes. Several markers have been found and corroborated by analysing two seasons samples. A seasonal independent marker was found and its structure elucidated using accurate mass data and MS(E) fragmentation spectrum information. Empirical formula was searched in Reaxys database applying sub-structure filtering from the fragments obtained. Three possible structures were found and citrusin D, a compound present in sweet oranges, has been identified as the most plausible as it fits better with the product ion scan performed for this compound. As a result of data obtained in this work, citrusin D is suggested as a potential marker to distinguish the geographic origin of oranges. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. [Determination of 6 kinds of plant growth regulator in bean sprout by ultra high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Liu, Ping; Fan, Sai; Wu, Guohua; Zhao, Rong; Liu, Wei; Zhao, Xudong

    2016-05-01

    A method for the simultaneous determination of 6 plant growth regulator (PGR) residues in bean sprout was developed by ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). 6-Benzylaminopurine, isopentennyladenine, 4-chlorophenoxyacetic acid, 4-fluorophenoxyacetic acid, indole-3- acetic acid and indole-3-butyric acid were concerned. Bean sprout samples were extracted by acetonitrile and QuEChERS extraction kit, purified by C18 powers. After centrifugation, the sample liquids was diluted 10 times by ultrapure water. The chromatographic analysis was carried out on an waters acquity UPLC BEH C18 column( 100 mm x 2.1 mm, 1.7 microm). The analyzer confirmed and quantified by mass spectrum of triple quadrupole in the multiple reaction monitoring (MRM) mode and quantified by matrix-matched external standard method. The calibration curves showed good linearity in each range with correlation coefficients greater than 0.998. 3 levels spiked recoveries were carried out using blank bean sprout extraction as substrate, the recoveries ranged from 84.2% to 107.5%, the relative standard deviations (RSDs) ranged from 3.08% to 12.71%. The qualitative limits of detections (S/N = 3) were 0.03-3.0 microg/kg and the quantitative limits(S/N = 10) were 0.1-10.0 microg/kg for the 6 PGRs. The method is simple and easy to operate, with less organic reagent, high sensitivity and good stability. It is suitable for the detection of 6 kinds of plant growth regulators in bean sprouts.

  11. Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

    NASA Technical Reports Server (NTRS)

    Worstell, J. H.; Daniel, S. R.

    1981-01-01

    A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

  12. [Determination of 12 flavonoids in tobacco leaves using ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Li, Yong; Lin, Qian; Pang, Tao; Shi, Junli

    2015-07-01

    Flavonoids are very important secondary metabolites for tobacco plants. They are also considered as important flavor precursors for cigarettes. A method of ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was established for the simultaneous determination of 12 flavonoids in tobacco leaves. The developed method determined 10 more flavonoids compared to the traditional method. A solution of methanol-water-chloroform (5:2:2, v/v/v) was used to extract the flavonoids from tobacco leaves and remove the pigment. Instrument analysis using the UPLC-MS/MS was completed in 13 min. The method validation was performed, and the results showed that the linear correlation coefficients (r2) of all the 12 flavonoids were more than 0.99. The limits of detection and the limits of quantification were in the range of 0.3-100 μg/L and 1.2-400 μg/L, respectively. Intra-day and Inter-day reproducibilities were in the range of 3.5%-7.4% and 5.2%-11.4%, respectively. The recoveries were 81.2%-111.9%. The established method was successfully used to analyze the flavonoids of tobacco leaves of 11 varieties. Significant concentration differences of the flavonoids were found among the determined varieties. Furthermore, significant positive correlation among the flavonoids with similar chemical structures (aglycones and their related glycosides, glycosides with the same aglycone, and similar aglycones) was found using the acquired data.

  13. Determination of naphthalene-derived compounds in apples by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Esparza, X; Moyano, E; Cosialls, J R; Galceran, M T

    2013-06-11

    Naphthylacetic acid, naphthyloxy acetic acid and naphthylacetamide belong to a group of synthetic substances known as "auxin-like" compounds which are used as growth regulators in vegetables and fruits due to their structure similarities with the indoleacetic acid, the most important plant auxin. This paper reports a selective, sensitive and fast ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of naphthylacetamide (NAD) and the isomers (α and β) of naphthylacetic acid (NAA) and naphthyloxy acetic (NOA) acid in apple samples. A baseline separation between the respective isomers was achieved using an RP-Amide column with gradient elution. The UHPLC-MS/MS method developed, using electrospray and selected reaction monitoring (SRM) acquisition mode led to a reliable determination of these family of compounds in apple samples at low quantitation levels, down to 1.0 μg kg(-1) and 0.25 μg kg(-1) respectively. For confirmation of NAA accurate mass measurement is proposed giving at these conditions quantitation limits of 10 μg kg(-1) for this compound. The UHPLC-MS/MS method developed was used for the analysis of apple samples harvested in three different apple fields from Lleida (Spain) during the blooming period. NAD and NAA were found in samples collected during 4-5 weeks after application at concentrations between the quantification limits and 43 μg kg(-1) and 24 μg kg(-1), respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Multiresidue analysis of sulfonamides, quinolones, and tetracyclines in animal tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Zhiwen; Li, Xiaowei; Ding, Shuangyang; Jiang, Haiyang; Shen, Jianzhong; Xia, Xi

    2016-08-01

    A multiresidue method for the efficient identification and quantification of 38 compounds from 3 different classes of antibiotics (tetracyclines, sulfonamides, and quinolones) in animal tissues has been developed. The method optimization involved the selection of extraction solutions, comparison of different solid-phase extraction cartridges and different mobile phases. As a result, the samples were extracted with Mcllvaine and phosphate buffers, followed by clean-up step based on solid-phase extraction with Oasis HLB cartridge. All compounds were determined by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9min. The method efficiency was evaluated in 5 tissues including muscle, liver, and kidney, and the mean recoveries ranged from 54% to 102%, with inter-day relative standard deviation lower than 14%. The limits of quantification were between 0.5 and 10μg/kg, which were satisfactory to support future surveillance monitoring. The developed method was applied to the analysis of swine liver and chicken samples from local markets, and sulfamethazine was the most commonly detected compound in the animal samples, with the highest residue level of 998μg/kg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Serum metabolic profiling study of lung cancer using ultra high performance liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Li, Yanjie; Song, Xue; Zhao, Xinjie; Zou, Lijuan; Xu, Guowang

    2014-09-01

    Lung cancer is currently the leading cause of cancer-related mortality worldwide. It is, therefore, important to enhance understanding and add a new auxiliary detection tool of lung cancer. In this work, serum metabolic characteristics of lung cancer were investigated with a non-targeted metabolomics method. The metabolic profiling of 23 patients with lung cancer and 23 healthy controls were analyzed using ultra high performance liquid chromatography/quadrupole time of flight mass spectrometry (UPLC/Q-TOF MS). Partial least squares discriminant analysis (PLS-DA) model of the metabolic data allowed the clear separation of the lung cancer patients from the healthy controls. In total, 27 differential metabolites were identified, which were mostly related to the perturbation of lipid metabolism, including choline, free fatty acids, lysophosphatidylcholines, etc. Choline and linoleic acid were defined as one combinational biomarker using binary logistic regression, which was supported by the validation with a smaller sample-set (9 patients and 9 healthy controls). These findings show that LC/MS-based serum metabolic profiling has potential application in complementary identification of lung cancer patients, and could be a powerful tool for cancer research. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry for arsenic speciation.

    PubMed

    Cheng, Heyong; Shen, Lihuan; Liu, Jinhua; Xu, Zigang; Wang, Yuanchao

    2018-04-01

    Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high-pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high-performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high-performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C 18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9-1.8 μg/L were obtained with precisions variable in the range of 1.6-4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87-102%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Biomonitoring of 21 endocrine disrupting chemicals in human hair samples using ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rodríguez-Gómez, R; Martín, J; Zafra-Gómez, A; Alonso, E; Vílchez, J L; Navalón, A

    2017-02-01

    Rapid industrial growth has increased human exposure to a large variety of chemicals with adverse health effects. These industrial chemicals are usually present in the environment, foods, beverages, clothes and personal care products. Among these compounds, endocrine disrupting chemicals (EDCs) have raised concern over the last years. In the present work, the determination of 21 EDCs in human hair samples is proposed. An analytical method based on the digestion of the samples with a mixture of acetic acid/methanol (20:80, v/v) followed by a solid-liquid microextraction and analysis by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and validated. The most influential parameters affecting the extraction method were optimized. The method was validated using matrix-matched calibration and recovery assays. Limits of detection ranged from 0.2 to 4 ng g -1 , limits of quantification from 0.5 to 12 ng g -1 , and inter- and intra-day variability was under 15% in all cases. Recovery rates for spiked samples ranged from 92.1 to 113.8%. The method was applied for the determination of the selected compounds in human hair. Samples were collected weekly from six randomly selected volunteers (three men and three women) over a three-month period. All the analyzed samples tested positive for at least one of the analyzed compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. [Blood levels of homocysteine by high pressure liquid chromatography and comparison with two other techniques].

    PubMed

    Ceppa, F; Drouillard, I; Chianea, D; Burnat, P; Perrier, F; Vaillant, C; El Jahiri, Y

    1999-01-01

    Cardio-vascular diseases are the most common cause of death in industrialized countries. A new marker has emerged among offending risk factors in the past few years: homocysteine. This sulphured amino-acid is an important intermediate in transsulphuration and remethylation reactions of methionine's metabolism. We proposed to evaluate a home made method of determination for this parameter by high performance liquid chromatography (HPLC) and to compare it to fluorescence polarization immunoassay technique (FPIA) and to gaz phase chromatography (CG-SM). This method associated with good sensibility and precision remain much less expensive than FPIA technique.

  19. Simultaneous determination of 24 personal care products in fish muscle and liver tissues using QuEChERS extraction coupled with ultra pressure liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometer analyses.

    PubMed

    Yao, Li; Zhao, Jian-Liang; Liu, You-Sheng; Yang, Yuan-Yuan; Liu, Wang-Rong; Ying, Guang-Guo

    2016-11-01

    A sensitive and selective quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction combined with dispersive solid-phase extraction (d-SPE) cleanup method was developed to simultaneously extract a wide range of personal care products (16 biocides, 4 synthetic musks, and 4 benzotriazoles) in fish muscle and liver tissues. In order to get satisfactory recoveries, different extraction parameters were optimized, including extraction salts and d-SPE materials, extraction solvents and acetic acid contents in organic phase, and the ratios of solvent and water. Ultra pressure liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry were used to analyze the target compounds in the extracts. Among the 24 personal care products, the recoveries in the range of 70-120 % were obtained for 20, 19, and 12 analytes in fish muscle at the spiking concentrations of 10, 5, and 1 ng/g ww, respectively, and for 13, 12, and 11 analytes in liver at the spiking concentrations of 40, 20, and 4 ng/g ww, respectively. Method quantification limits (MQLs) of all analytes were 0.02-2.12 ng/g ww for fish muscle and 0.22-12.2 ng/g ww for fish liver tissues. The method was successfully applied to wild fish samples collected from Dongjiang River, south China. Twenty-one and 17 of the analytes were found in fish muscle and liver samples, respectively, in at least one site of the river with the concentrations between below MQLs and 119 ng/g ww, respectively. Graphical abstract Achieved satisfactory recoveries, high precision, and low method quantification limits (MQLs) for PCPs in wild fish tissues by QuEChERS procedure optimization combined with UPLC-MS/MS and GC-MS analyses.

  20. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    PubMed

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. [Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

    PubMed

    Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István

    2008-01-13

    Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention

  2. Rapid quantification of pharmaceuticals and pesticides in passive samplers using ultra high performance liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Wille, Klaas; Claessens, Michiel; Rappé, Karen; Monteyne, Els; Janssen, Colin R; De Brabander, Hubert F; Vanhaecke, Lynn

    2011-12-23

    The presence of both pharmaceuticals and pesticides in the aquatic environment has become a well-known environmental issue during the last decade. An increasing demand however still exists for sensitive and reliable monitoring tools for these rather polar contaminants in the marine environment. In recent years, the great potential of passive samplers or equilibrium based sampling techniques for evaluation of the fate of these contaminants has been shown in literature. Therefore, we developed a new analytical method for the quantification of a high number of pharmaceuticals and pesticides in passive sampling devices. The analytical procedure consisted of extraction using 1:1 methanol/acetonitrile followed by detection with ultra-high performance liquid chromatography coupled to high resolution and high mass accuracy Orbitrap mass spectrometry. Validation of the analytical method resulted in limits of quantification and recoveries ranging between 0.2 and 20 ng per sampler sheet and between 87.9 and 105.2%, respectively. Determination of the sampler-water partition coefficients of all compounds demonstrated that several pharmaceuticals and most pesticides exert a high affinity for the polydimethylsiloxane passive samplers. Finally, the developed analytical methods were used to measure the time-weighted average (TWA) concentrations of the targeted pollutants in passive samplers, deployed at eight stations in the Belgian coastal zone. Propranolol, carbamazepine and seven pesticides were found to be very abundant in the passive samplers. These obtained long-term and large-scale TWA concentrations will contribute in assessing the environmental and human health risk of these emerging pollutants. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Ultra-high performance size-exclusion chromatography in polar solvents.

    PubMed

    Vancoillie, Gertjan; Vergaelen, Maarten; Hoogenboom, Richard

    2016-12-23

    Size-exclusion chromatography (SEC) is amongst the most widely used polymer characterization methods in both academic and industrial polymer research allowing the determination of molecular weight and distribution parameters, i.e. the dispersity (Ɖ), of unknown polymers. The many advantages, including accuracy, reproducibility and low sample consumption, have contributed to the worldwide success of this analytical technique. The current generation of SEC systems have a stationary phase mostly containing highly porous, styrene-divinylbenzene particles allowing for a size-based separation of various polymers in solution but limiting the flow rate and solvent compatibility. Recently, sub-2μm ethylene-bridged hybrid (BEH) packing materials have become available for SEC analysis. These packing materials can not only withstand much higher pressures up to 15000psi but also show high spatial stability towards different solvents. Combining these BEH columns with the ultra-high performance LC (UHPLC) technology opens up UHP-SEC analysis, showing strongly reduced runtimes and unprecedented solvent compatibility. In this work, this novel characterization technique was compared to conventional SEC using both highly viscous and highly polar solvents as eluent, namely N,N-dimethylacetamide (DMAc), N,N-dimethylformamide (DMF) and methanol, focusing on the suitability of the BEH-columns for analysis of highly functional polymers. The results show a high functional group compatibility comparable with conventional SEC with remarkably short runtimes and enhanced resolution in methanol. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites.

    PubMed

    Xie, Li; Chen, Liqin; Gu, Pan; Wei, Lanlan; Kang, Xuejun

    2018-03-01

    The extraction and analysis of catecholamine neurotransmitters in biological fluids is of great importance in assessing nervous system function and related diseases, but their precise measurement is still a challenge. Many protocols have been described for neurotransmitter measurement by a variety of instruments, including high-pressure liquid chromatography (HPLC). However, there are shortcomings, such as complicated operation or hard-to-detect multiple targets, which cannot be avoided, and presently, the dominant analysis technique is still HPLC coupled with sensitive electrochemical or fluorimetric detection, due to its high sensitivity and good selectivity. Here, a detailed protocol is described for the pretreatment and detection of catecholamines with high pressure liquid chromatography with electrochemical detection (HPLC-ECD) in real urine samples of infants, using electrospun composite nanofibers composed of polymeric crown ether with polystyrene as adsorbent, also known as the packed-fiber solid phase extraction (PFSPE) method. We show how urine samples can be easily precleaned by a nanofiber-packed solid phase column, and how the analytes in the sample can be rapidly enriched, desorbed, and detected on an ECD system. PFSPE greatly simplifies the pretreatment procedures for biological samples, allowing for decreased time, expense, and reduction of the loss of targets. Overall, this work illustrates a simple and convenient protocol for solid-phase extraction coupled to an HPLC-ECD system for simultaneous determination of three monoamine neurotransmitters (norepinephrine (NE), epinephrine (E), dopamine (DA)) and two of their metabolites (3-methoxy-4-hydroxyphenylglycol (MHPG) and 3,4-dihydroxy-phenylacetic acid (DOPAC)) in infants' urine. The established protocol was applied to assess the differences of urinary catecholamines and their metabolites between high-risk infants with perinatal brain damage and healthy controls. Comparative analysis revealed a

  5. Semiautomated determination of neonicotinoids and characteristic metabolite in urine samples using TurboFlow™ coupled to ultra high performance liquid chromatography coupled to Orbitrap analyzer.

    PubMed

    López-García, Marina; Romero-González, Roberto; Lacasaña, Marina; Garrido Frenich, Antonia

    2017-11-30

    A semiautomated method based on ultra-high performance liquid chromatography (UHPLC) coupled to Orbitrap high resolution mass spectrometry has been developed for the determination of neonicotinoids (imidacloprid, acetamiprid, clothianidin, dinotefuran, nitenpyram, thiacloprid and thiamethoxam) and the metabolite acetamiprid-n-desmethyl in urine samples. Two automated methods were tested (solid-phase extraction "SPE" and turbulent flow chromatography "TurboFlow™"), obtaining the best results when TurboFlow™ was applied. The total analysis time for the developed method was 14min. The optimized method was validated, obtaining suitable results for all validation parameters. Recoveries ranged from 78% to 116% meanwhile repeatability and reproducibility were evaluated obtaining values lower than 10% and 20% respectively (except for dinotefuran and nitenpyram at 0.2μgL -1 ). The limit of quantification (LOQ) for all compounds was established at 0.2μgL -1 . The proposed analytical methodology was applied to analyze the target compounds in thirty six urine samples from pregnant women living in agricultural areas of Almería (Spain). Imidacloprid, acetamiprid and acetamiprid-n-desmethyl were detected in some of the samples at concentrations ranging from 0.23 to 1.57μgL -1 . Furthermore, dinotefuran was identified in two samples at trace levels. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Characterization of phenolic amides from cortex lycii by ultra high-performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  7. An improved analytical strategy combining microextraction by packed sorbent combined with ultra high pressure liquid chromatography for the determination of fluoxetine, clomipramine and their active metabolites in human urine.

    PubMed

    Alves, Vera; Gonçalves, João; Conceição, Carlota; Teixeira, Helena M; Câmara, José S

    2015-08-21

    A powerful and sensitive method, by microextraction packed sorbent (MEPS), and ultra-high performance liquid chromatography (UHPLC) with a photodiode array (PDA) detection, is described for the determination of fluoxetine, clomipramine and their active metabolites in human urine samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) were optimized. The analysis were carried out using small sample volumes (500μL) and in a short time period (5min for the entire sample preparation step). Good linearity was obtained for all antidepressants with the correlation coefficients (R(2)) above 0.9965. The limits of detection (LOD) ranged from 0.068 to 0.087μgmL(-1). The recoveries were from 93% to 98%, with relative standard deviations less than 6%. The inter-day precision, expressed as the relative standard deviation, varied between 3.8% and 8.5% while the intra-day precision between 3.0% and 7.1%. In order to evaluate the proposed method for clinical use, the MEPS/UHPLC-PDA method was applied to analysis of urine samples from depressed patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. High-pressure liquid-monopropellant strand combustion.

    NASA Technical Reports Server (NTRS)

    Faeth, G. M.

    1972-01-01

    Examination of the influence of dissolved gases on the state of the liquid surface during high-pressure liquid-monopropellant combustion through the use of a strand burning experiment. Liquid surface temperatures were measured, using fine-wire thermocouples, during the strand combustion of ethyl nitrate, normal propyl nitrate, and propylene glycol dinitrate at pressures up to 81 atm. These measurements were compared with the predictions of a variable-property gas-phase analysis assuming an infinite activation energy for the decomposition reaction. The state of the liquid surface was estimated using a conventional low-pressure phase equilibrium model, as well as a high-pressure version that considered the presence of dissolved combustion-product gases in the liquid phase. The high-pressure model was found to give a superior prediction of measured liquid surface temperatures. Computed total pressures required for the surface to reach its critical mixing point during strand combustion were found to be in the range from 2.15 to 4.62 times the critical pressure of the pure propellant. Computed dissolved gas concentrations at the liquid surface were in the range from 35 to 50% near the critical combustion condition.

  9. Analysis of legal high materials by ultra-performance liquid chromatography with time of flight mass spectrometry as part of a toxicology vigilance system: what are the most popular novel psychoactive substances in the UK?

    PubMed

    Ford, Loretta T; Berg, Jonathan D

    2017-03-01

    Introduction Legal highs also known as novel psychoactive substances mimic the effects of classic drugs of abuse. Challenges to developing screening services for novel psychoactive substances include identifying which novel psychoactive substances are available to target. Using new techniques such as exact mass time of flight can help identify common novel psychoactive substances to target for screening patient samples by routine methods such as tandem mass spectrometry. We demonstrate this strategy working in our own clinical toxicology laboratory after qualitative analysis of 98 suspect materials for novel psychoactive substances by ultra-performance liquid chromatography with time of flight mass spectrometry. Results From July 2014 to July 2015 we received 98 requests to test a range of different suspect materials for novel psychoactive substances including herbs, tobacco, liquids, pills and powders. Overall, 87% of the suspect materials tested positive for novel psychoactive substances, and 15% for controlled drugs. Three common novel psychoactive substances were present in 74% of the suspect materials: methiopropamine, a methamphetamine analogue; ethylphenidate, a cocaine mimic; and the third generation synthetic cannabinoid 5F-AKB-48. For the 55 branded products we tested only 24% of the stated contents matched exactly the compounds we detected. Conclusion Testing suspect materials using ultra-performance liquid chromatography with time of flight mass spectrometry has identified three common novel psychoactive substances in use in the UK, simplifying the development of a relevant novel psychoactive substances screening service to our population. By incorporating this into our routine liquid chromatography tandem mass spectrometry drugs of abuse screen, then offers a clinically relevant novel psychoactive substances service to our users. This strategy ensures our clinical toxicology service continues to remain effective to meet the challenges of the changing

  10. An ultra-pressure liquid chromatography-tandem mass spectrometry method for the simultaneous determination of three physalins in rat plasma and its application to pharmacokinetic study of Physalis alkekengi var. franchetii (Chinese lantern) in rats.

    PubMed

    Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang

    2012-01-25

    An ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of three major ingredients in Chinese lantern preparations (CLP) in rat plasma. Following extraction by ethyl acetate, the analytes were separated on an Acquity UPLC BEH Shield RP C(18) column using a gradient mobile phase system of acetonitrile-water. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curves were linear over the range of 5.0-500.0 ng/ml for physalin D, 2.3-230.0 ng/ml for physalin G and 0.71-71.0 ng/ml for 4,7-didehydroneophysalin B. The average extraction recoveries, examined at four concentration levels, carried from 57.1% to 76.9%, and the accuracies ranged from 94.0% to 113.3% with precision (RSD) <15%. The validated method was successfully applied to the determination of the three physalins in rat plasma after intragastric administration of CLP suspension. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Metabolic profile of esculin in rats by ultra high performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    PubMed

    Wang, Yinan; Zhao, Min; Ou, Yingfu; Zeng, Bowen; Lou, Xinyu; Wang, Miao; Zhao, Chunjie

    2016-05-01

    Esculin, a coumarin derivative found in Fraxinus rhynchophylla, has been reported to possess multiple biological activities. This present study is designed to investigate the metabolic profile of esculin in vivo based on ultra high performance liquid chromatography coupled to Fourier transform ion cyclotron resonance mass spectrometry (UHPLC-FT-ICR-MS) for the first time. After oral administration of esculin (100 mg/kg) for rats, plasma, urine, feces and bile samples were collected to screen metabolites. As a result, a total of 19 metabolites (10 phase I metabolites and 9 phase II metabolites) were found and identified. Results showed that metabolic pathways of esculin included hydrolysis, dehydrogenation, hydroxylation, methylation, dehydrogenation, glucuronidation, sulfation, and glycine conjugation. It was also found that after oral administration of esculin, the esculin could be metabolized to esculetin in vivo via deglycosylation, and esculetin was found in all biological samples. This study also laid solid basis for in-depth development of esculin and provided important information for clarifying the biotransformation process of esculin in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparative analysis of sixteen flavonoids from different parts of Sophora flavescens Ait. by ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Weng, Zebin; Zeng, Fei; Zhu, Zhenhua; Qian, Dawei; Guo, Sheng; Wang, Hanqing; Duan, Jin-Ao

    2018-07-15

    The root of Sophora flavescens Ait. has long been used as a crude drug in China and other Asian countries for thousands of years. The quinolizidine alkaloids and flavonoids are considered as the main bioactive components in this plant. To determine the distribution and content of the flavonoids in different organs of this plant, a rapid, sensitive and reproducible method was established using ultra-high-performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry. A total of sixteen flavonoids including five different types (isoflavones, pterocarpans, flavones, flavonols and prenylflavonoids) were simultaneously determined in 10 min. The established method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery and successfully applied in the methanolic extracts of S. flavescens parts (root, stem, leaf, pod and seed). The analysis results indicated that the distribution and contents of different type of flavonoids showed remarkable differences among the five organs of S. flavescens. This study might be useful for the rational utilization of S. flavescens resource. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. A Manganin Thin Film Ultra-High Pressure Sensor for Microscale Detonation Pressure Measurement

    PubMed Central

    Zhang, Guodong; Zhao, Yulong; Zhao, Yun; Wang, Xinchen; Ren, Wei; Li, Hui; Zhao, You

    2018-01-01

    With the development of energetic materials (EMs) and microelectromechanical systems (MEMS) initiating explosive devices, the measurement of detonation pressure generated by EMs in the microscale has become a pressing need. This paper develops a manganin thin film ultra-high pressure sensor based on MEMS technology for measuring the output pressure from micro-detonator. A reliable coefficient is proposed for designing the sensor’s sensitive element better. The sensor employs sandwich structure: the substrate uses a 0.5 mm thick alumina ceramic, the manganin sensitive element with a size of 0.2 mm × 0.1 mm × 2 μm and copper electrodes of 2 μm thick are sputtered sequentially on the substrate, and a 25 μm thick insulating layer of polyimide is wrapped on the sensitive element. The static test shows that the piezoresistive coefficient of manganin thin film is 0.0125 GPa−1. The dynamic experiment indicates that the detonation pressure of micro-detonator is 12.66 GPa, and the response time of the sensor is 37 ns. In a word, the sensor developed in this study is suitable for measuring ultra-high pressure in microscale and has a shorter response time than that of foil-like manganin gauges. Simultaneously, this study could be beneficial to research on ultra-high-pressure sensors with smaller size. PMID:29494519

  14. Analysis of aldehydes in beer by gas-diffusion microextraction: characterization by high-performance liquid chromatography-diode-array detection-atmospheric pressure chemical ionization-mass spectrometry.

    PubMed

    Gonçalves, Luís Moreira; Magalhães, Paulo Jorge; Valente, Inês Maria; Pacheco, João Grosso; Dostálek, Pavel; Sýkora, David; Rodrigues, José António; Barros, Aquiles Araújo

    2010-06-11

    In this work, a recently developed extraction technique for sample preparation aiming the analysis of volatile and semi-volatile compounds named gas-diffusion microextraction (GDME) is applied in the chromatographic analysis of aldehydes in beer. Aldehydes-namely acetaldehyde (AA), methylpropanal (MA) and furfural (FA)-were simultaneously extracted and derivatized with 2,4-dinitrophenylhydrazine (DNPH), then the derivatives were separated and analyzed by high-performance liquid chromatography with spectrophotometric detection (HPLC-UV). The identity of the eluted compounds was confirmed by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass-spectrometry detection in the negative ion mode (HPLC-APCI-MS). The developed methodology showed good repeatability (ca. 5%) and linearity as well as good limits of detection (AA-12.3, FA-1.5 and MA 5.4microgL(-1)) and quantification (AA-41, FA-4.9 and MA 18microgL(-1)); it also appears to be competitive in terms of speed and cost of analysis. Copyright 2010 Elsevier B.V. All rights reserved.

  15. [Screening and confirmation of 24 hormones in cosmetics by ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    PubMed

    Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui

    2014-05-01

    A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were < or = 10 microg/kg, which can meet the requirements for the actual screening of cosmetic samples. The developed method was applied to screen the hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.

  16. Direct large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry determination of artificial sweeteners sucralose and acesulfame in well water.

    PubMed

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Hrudey, Steve E; Le, X Chris; Li, Xing-Fang

    2014-09-12

    Acesulfame (ACE) and sucralose (SUC) have become recognized as ideal domestic wastewater contamination indicators. Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis is commonly used; however, the sensitivity of SUC is more than two orders of magnitude lower than that of ACE, limiting the routine monitoring of SUC. To address this issue, we examined the ESI behavior of both ACE and SUC under various conditions. ACE is ionic in aqueous solution and efficiently produces simple [M-H](-) ions, but SUC produces multiple adduct ions, limiting its sensitivity. The formic acid (FA) adducts of SUC [M+HCOO](-) are sensitively and reproducibly generated under the LC-MS conditions. When [M+HCOO](-) is used as the precursor ion for SUC detection, the sensitivity increases approximately 20-fold compared to when [M-H](-) is the precursor ion. To further improve the limit of detection (LOD), we integrated the large volume injection approach (500μL injection) with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which reduced the method detection limit (MDL) to 0.2ng/L for ACE and 5ng/L for SUC. To demonstrate the applicability of this method, we analyzed 100 well water samples collected in Alberta. ACE was detected in 24 wells at concentrations of 1-1534ng/L and SUC in 8 wells at concentrations of 65-541ng/L. These results suggest that wastewater is the most likely source of ACE and SUC impacts in these wells, suggesting the need for monitoring the quality of domestic well water. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Profiling of steroid metabolites after transdermal and oral administration of testosterone by ultra-high pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry.

    PubMed

    Badoud, F; Boccard, J; Schweizer, C; Pralong, F; Saugy, M; Baume, N

    2013-11-01

    The screening of testosterone (T) misuse for doping control is based on the urinary steroid profile, including T, its precursors and metabolites. Modifications of individual levels and ratio between those metabolites are indicators of T misuse. In the context of screening analysis, the most discriminant criterion known to date is based on the T glucuronide (TG) to epitestosterone glucuronide (EG) ratio (TG/EG). Following the World Anti-Doping Agency (WADA) recommendations, there is suspicion of T misuse when the ratio reaches 4 or beyond. While this marker remains very sensitive and specific, it suffers from large inter-individual variability, with important influence of enzyme polymorphisms. Moreover, use of low dose or topical administration forms makes the screening of endogenous steroids difficult while the detection window no longer suits the doping habit. As reference limits are estimated on the basis of population studies, which encompass inter-individual and inter-ethnic variability, new strategies including individual threshold monitoring and alternative biomarkers were proposed to detect T misuse. The purpose of this study was to evaluate the potential of ultra-high pressure liquid chromatography (UHPLC) coupled with a new generation high resolution quadrupole time-of-flight mass spectrometer (QTOF-MS) to investigate the steroid metabolism after transdermal and oral T administration. An approach was developed to quantify 12 targeted urinary steroids as direct glucuro- and sulfo-conjugated metabolites, allowing the conservation of the phase II metabolism information, reflecting genetic and environmental influences. The UHPLC-QTOF-MS(E) platform was applied to clinical study samples from 19 healthy male volunteers, having different genotypes for the UGT2B17 enzyme responsible for the glucuroconjugation of T. Based on reference population ranges, none of the traditional markers of T misuse could detect doping after topical administration of T, while the

  18. [Separation and identification of 5 glycosidic flavor precursors in tobacco by ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry].

    PubMed

    Wu, Xinhua; Zhu, Ruizhi; Ren, Zhuoying; Wang, Kai; Mou, Dingrong; Wei, Wanzhi; Miao, Mingming

    2009-11-01

    A qualitative method for the identification of 5 main glycosidic flavor precursors in tobacco was developed by using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS) and gas chromatography-mass spectrometry (GC-MS). The glycosidic flavor precursors in tobacco were extracted with methanol, cleaned up with an XAD-2 column. The aglycones were later released by enzyme-mediated hydrolysis under the condition of pH 5. The 5 volatile aglycone moieties were identified by GC-MS standard spectra library. The precursor ions of glycosides were determined by using electrospray ionization mass spectrometry in negative ion mode, then the 5 glycosidic flavor precursors were identified by using product ion scan (MS2) finally, using UPLC-ESI MS/MS, separation and identification of 5 glycosidic flavor precursors were accomplished on an RP-C,8 column in the multiple reaction monitoring (MRM) mode by using methanol and acetic acid-ammonium acetate aqueous solution as eluent. This work lays a foundation for the analysis of glycosidic flavor precursors without the standards by using liquid chromatography-mass spectrometry.

  19. Purification and identification of corn peptides that facilitate alcohol metabolism by semi-preparative high-performance liquid chromatography and nano liquid chromatography with electrospray ionization tandem mass spectrometry.

    PubMed

    Ma, Zhi-Li; Hou, Tao; Shi, Wen; Liu, Wei-Wei; Ibrahim, Salam A; He, Hui

    2016-11-01

    In this study, peptides that facilitate alcohol metabolism were purified and identified from corn protein hydrolysates. The ultra-filtered fraction with a molecular weight < 3 kDa (F3) potential activity was separated into six fractions (F3-H1-F3-H6) by semi-preparative high-performance liquid chromatography. Among the resultant six fractions, F3-H4 and F3-H5 exhibited the highest ability to eliminate alcohol in vivo. A total of 16 peptides with strong signal values were identified from F3-H4 and F3-H5 fractions by nano liquid chromatography coupled with electrospray ionization tandem mass spectrometry. Several identified peptides were then selected and synthesized to determine their potential to facilitate alcohol metabolism. We found that Leu-Leu and Pro-Phe were the key structure units in Gln-Leu-Leu-Pro-Phe responsible for this peptide's ability to facilitate alcohol metabolism. However, the role of Leu-Leu and Pro-Phe may be affected by peptide chain length and hydrophobic properties. Our results have thus provided some insight into the study of the structure-activity relationships of corn peptides. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Identification and quantification of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide (THC-COOH-glu) in hair by ultra-performance liquid chromatography tandem mass spectrometry as a potential hair biomarker of cannabis use.

    PubMed

    Pichini, Simona; Marchei, Emilia; Martello, Simona; Gottardi, Massimo; Pellegrini, Manuela; Svaizer, Fiorenza; Lotti, Andrea; Chiarotti, Marcello; Pacifici, Roberta

    2015-04-01

    We developed and validated an ultra-high-pressure liquid chromatography-tandem mass spectrometry method to identify and quantify 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in hair of cannabis consumers. After hair washing with methyl alcohol and diethyl ether and subsequent addition of amiodarone as internal standard hair samples were treated with 500 μl VMA-T M3 buffer reagent for 1 h at 100 °C. After cooling, 10 μl VMA-T M3 extract were injected into chromatographic system. Chromatographic separation was carried out on a reversed phase column using a linear gradient elution with two solvents: 5 mM ammonium formate pH 3.0 (solvent A) and 0.1% formic acid in acetonitrile (solvent B). The flow rate was kept constant at 0.4 ml/min during the analysis. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring mode via positive electrospray ionization. Linear calibration curves were obtained for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide with correlation coefficients (r(2)) of 0.99 and a limit of quantification of 0.25 pg/mg hair. Analytical recovery was between 79.6% and 100.7% and intra- and inter-assay imprecision and inaccuracy were always lower than 15%. Ultra-high-pressure liquid chromatography-tandem mass spectrometry analysis of 20 different hair samples of cannabis consumers disclosed the presence of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in the range of 0.5-8.6 pg/mg hair. These data provided a good start to consider 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide as alternative hair biomarker of cannabis consumption. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    ERIC Educational Resources Information Center

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  2. Analysis of chloramphenicol residues in the macroalgae Ulva lactuca through ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS).

    PubMed

    Leston, Sara; Freitas, Andreia; Nunes, Margarida; Barbosa, Jorge; Pardal, Miguel Ângelo; Ramos, Fernando

    2015-02-15

    Antibiotic use is a well-described practice to promote animal health whether for prevention or treatment. Nonetheless, it can also cause a number of potentially harmful effects that dictate the need to implement regulation to assure a reduction of hazards to the consumers and the environment. Chloramphenicol (CAP) is a broad-spectrum antibacterial excluded from use in animal food production but despite this, reports of illegal use still persist. More recently, awareness has risen that the surrounding natural ecosystems can potentially be contaminated by pharmaceuticals and the extent of their effects in non-target organisms is already under the scope of researchers. To face the demanding new challenges a methodology for the determination of CAP in the green macroalgae Ulva lactuca by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed, optimized and fully validated following the guidelines of the EC Decision 2002/657. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Simultaneous identification and quantification of bisphenol A and 12 bisphenol analogues in environmental samples using precolumn derivatization and ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Wang, Zhonghe; Yu, Jing; Yao, Jiaxi; Wu, Linlin; Xiao, Hang; Wang, Jun; Gao, Rong

    2018-02-10

    A method for the identification and quantification of bisphenol A and 12 bisphenol analogues in river water and sediment samples combining liquid-liquid extraction, precolumn derivatization, and ultra high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Analytes were extracted from the river water sample using a liquid-liquid extraction method. Dansyl chloride was selected as a derivatization reagent. Derivatization reaction conditions affecting production of the dansyl derivatives were tested and optimized. All the derivatized target compounds were well separated and eluted in 10 min. Dansyl chloride labeled compounds were analyzed using a high-resolution mass spectrometer with electrospray ionization in the positive mode, and the results were confirmed and quantified in the parallel reaction monitoring mode. The method validation results showed a satisfactory level of sensitivity. Linearity was assessed using matrix-matched standard calibration, and good correlation coefficients were obtained. The limits of quantification for the analytes ranged from 0.005 to 0.02 ng/mL in river water and from 0.15 to 0.80 ng/g in sediment. Good reproducibility of the method in terms of intra- and interday precision was achieved, yielding relative standard deviations of less than 10.1 and 11.6%, respectively. Finally, this method was successfully applied to the analysis of real samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Determination of 82 veterinary drugs in swine waste lagoon sludge by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Xiaowei; Guo, Ping; Shan, Yawen; Ke, Yuebin; Li, Hui; Fu, Qin; Wang, Yingyu; Liu, Tianhe; Xia, Xi

    2017-05-26

    This work reports the development of a multi-residue method for the identification and quantification of 82 veterinary drugs belonging to different chemical classes in swine waste lagoon. The proposed method applies a solid-phase extraction procedure with Oasis PRiME HLB cartridges that combines isolation of the compounds and sample clean-up in a single step. Analysis is performed by ultra-high performance liquid chromatography-tandem mass spectrometry, in one single injection with a chromatographic run time of only 9.5min. Linearity was studied in the range between 1 and 500μgkg -1 using standards prepared both in pure solvent and in the presence of matrix, showing coefficients of determination higher than 0.99 for all the analytes except for cefapirin in matrix. The average recoveries were in the range of 60-110% for most of the compounds tested with inter-day relative standard deviations below 17%. More than 97% of the investigated compounds had less or equal to a 5μgkg -1 quantitation limit in the studied matrix. Finally, the method was used with success to detect and quantify veterinary drugs residues in real samples with sulfonamides, quinolones, and tetracyclines being the most frequently determined compound groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Selective identification and quantification of saccharin by liquid chromatography and fluorescence detection.

    PubMed

    Bruno, Sergio N F; Cardoso, Carlos R; Maciel, Márcia Mosca A; Vokac, Lidmila; da Silva Junior, Ademário I

    2014-09-15

    High-pressure liquid chromatography with ultra-violet detection (HPLC-UV) is one of the most commonly used methods to identify and quantify saccharin in non-alcoholic beverages. However, due to the wide variety of interfering UV spectra in saccharin-containing beverage matrices, the same method cannot be used to measure this analyte accurately. We have developed a new, highly effective method to identify and quantify saccharin using HPLC with fluorescence detection (HPLC-FLD). The excitation wavelength (250 nm) and emission wavelength (440 nm) chosen increased selectivity for all matrices and ensured few changes were required in the mobile phase or other parameters. The presence of saccharin in non-diet beverages - a fraud commonly used to replace more expensive sucrose - was confirmed by comparing coincident peaks as well as the emission spectra of standards and samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.

    PubMed

    Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L

    2006-02-01

    The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).

  7. Multichannel Detection in High-Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  8. Capillary liquid chromatography combined with pressurized liquid extraction and dispersive liquid-liquid microextraction for the determination of vitamin E in cosmetic products.

    PubMed

    Viñas, Pilar; Pastor-Belda, Marta; Campillo, Natalia; Bravo-Bravo, María; Hernández-Córdoba, Manuel

    2014-06-01

    Capillary liquid chromatography (LC) is used for the determination of tocopherols and tocotrienols in cosmetic products. Dispersive liquid-liquid microextraction (DLLME) allows the analytes to be preconcentrated into a very small volume of organic solvent which is then injected into the chromatograph running at a very low flow rate. Pressurized liquid extraction (PLE) at a high temperature and pressure was used to isolate vitamin E forms from cosmetics. The Taguchi experimental method was used to optimize the factors affecting DLLME. The parameters selected were 2mL of acetonitrile (disperser solvent), 100μL carbon tetrachloride (extraction solvent) and 10mL aqueous solution. A volume of 5μL of the organic phase was injected into the reversed-phase capillary LC system equipped with a diode array detector and using an isocratic mobile phase composed of an 95:5 (v/v) methanol:water mixture at a flow-rate of 20μLmin(-1). Quantification was carried out using aqueous standards and detection limits were in the range 0.1-0.5ngmL(-1), corresponding to 3-15ngg(-1) in the cosmetic sample. The recoveries were in the 87-105% range, with RSDs lower than 7.8%. The method was validated according to international guidelines and using a certified reference material. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats.

    PubMed

    Balla, Anusha; Cho, Kwan Hyung; Kim, Yu Chul; Maeng, Han-Joo

    2018-03-30

    A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N -acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi™ 4 µm polar, reversed-phase column using 1% acetic acid (pH 5.5) and methanol (76:24, v / v ) as eluent in isocratic mode at a flow rate 0.2 mL/min. The method showed good linearity ( r ² > 0.998) over the concentration range of 20-100,000 and 20-10,000 ng/mL for PA and NAPA, respectively. Intra- and inter-day accuracies ranged from 97.7 to 110.9%, and precision was <10.5% for PA and 99.7 to 109.2 and <10.5%, respectively, for NAPA. The lower limit of quantification was 20 ng/mL for both compounds. This is the first report of the UHPLC-DAD bioanalytical method for simultaneous measurement of PA and NAPA. The most obvious advantage of this method over previously reported HPLC methods is that it requires small sample and injection volumes, with a straightforward, one-step sample preparation. It overcomes the limitations of previous methods, which use large sample volume and complex sample preparation. The devised method was successfully applied to the quantification of PA and NAPA after an intravenous bolus administration of 10 mg/kg procainamide hydrochloride to rats.

  10. Chemical profiling of Qixue Shuangbu Tincture by ultra-performance liquid chromatography with electrospray ionization quadrupole-time-of-flight high-definition mass spectrometry (UPLC-QTOF/MS).

    PubMed

    Chen, Lin-Wei; Wang, Qin; Qin, Kun-Ming; Wang, Xiao-Li; Wang, Bin; Chen, Dan-Ni; Cai, Bao-Chang; Cai, Ting

    2016-02-01

    The present study was designed to develop and validate a sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-QTOF/MS) method to separate and identify the chemical constituents of Qixue Shuangbu Tincture (QXSBT), a classic traditional Chinese medicine (TCM) prescription. Under the optimized UPLC and QTOF/MS conditions, 56 components in QXSBT, including chalcones, triterpenoids, protopanaxatriol, flavones and flavanones were identified and tentatively characterized within a running time of 42 min. The components were identified by comparing the retention times, accurate mass, and mass spectrometric fragmentation characteristic ions, and matching empirical molecular formula with that of the published compounds. In conclusion, the established UPLC-QTOF/MS method was reliable for a rapid identification of complicated components in the TCM prescriptions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  11. Comprehensive comparison of liquid chromatography selectivity as provided by two types of liquid chromatography detectors (high resolution mass spectrometry and tandem mass spectrometry): "where is the crossover point?".

    PubMed

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2010-07-12

    The selectivity of mass traces obtained by monitoring liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was compared. A number of blank extracts (fish, pork kidney, pork liver and honey) were separated by ultra performance liquid chromatography (UPLC). Detected were some 100 dummy transitions respectively dummy exact masses (traces). These dummy masses were the product of a random generator. The range of the permitted masses corresponded to those which are typical for analytes (e.g. veterinary drugs). The large number of monitored dummy traces ensured that endogenous compounds present in the matrix extract, produced a significant number of detectable chromatographic peaks. All obtained chromatographic peaks were integrated and standardized. Standardisation was done by dividing these absolute peak areas by the average response of a set of 7 different veterinary drugs. This permitted a direct comparison between the LC-HRMS and LC-MS/MS data. The data indicated that the selectivity of LC-HRMS exceeds LC-MS/MS, if high resolution mass spectrometry (HRMS) data is recorded with a resolution of 50,000 full width at half maximum (FWHM) and a corresponding mass window. This conclusion was further supported by experimental data (MS/MS based trace analysis), where a false positive finding was observed. An endogenous matrix compound present in honey matrix behaved like a banned nitroimidazole drug. This included identical retention time and two MRM traces, producing an MRM ratio between them, which perfectly matched the ratio observed in the external standard. HRMS measurement clearly resolved the interfering matrix compound and unmasked the false positive MS/MS finding. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Ultra-high-performance liquid chromatography/tandem high-resolution mass spectrometry analysis of sixteen red beverages containing carminic acid: identification of degradation products by using principal component analysis/discriminant analysis.

    PubMed

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Marengo, Emilio

    2015-01-15

    The study investigates the sunlight photodegradation process of carminic acid, a natural red colourant used in beverages. For this purpose, both carminic acid aqueous standard solutions and sixteen different commercial beverages, ten containing carminic acid and six containing E120 dye, were subjected to photoirradiation. The results show different patterns of degradation, not only between the standard solutions and the beverages, but also from beverage to beverage. Due to the different beverage recipes, unpredictable reactions take place between the dye and the other ingredients. To identify the dye degradation products in a very complex scenario, a methodology was used, based on the combined use of principal component analysis with discriminant analysis and ultra-high-performance liquid chromatography coupled with tandem high resolution mass spectrometry. The methodology is unaffected by beverage composition and allows the degradation products of carminic acid dye to be identified for each beverage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Gas-liquid chromatography with a volatile "stationary" liquid phase.

    PubMed

    Wells, P S; Zhou, S; Parcher, J F

    2002-05-01

    A unique type of gas-liquid chromatography is described in which both mobile and "stationary" phases are composed of synthetic mixtures of helium and carbon dioxide. At temperatures below the critical point of the binary mixture and pressures above the vapor pressure of pure liquid carbon dioxide, helium and carbon dioxide can form two immiscible phases over extended composition ranges. A binary vapor phase enriched in helium can act as the mobile phase for chromatographic separations, whereas a CO2-rich liquid in equilibrium with the vapor phase, but condensed on the column wall, can act as a pseudostationary phase. Several examples of chromatographic separations obtained in "empty" capillary columns with no ordinary stationary liquid phase illustrate the range of conditions that produce such separations. In addition, several experiments are reported that confirm the proposed two-phase hypothesis. The possible consequences of the observed chromatographic phenomenon in the field of supercritical fluid chromatography with helium headspace carbon dioxide are discussed.

  14. Application of statistical experimental design to the optimisation of microextraction by packed sorbent for the analysis of nonsteroidal anti-inflammatory drugs in human urine by ultra-high pressure liquid chromatography.

    PubMed

    Magiera, Sylwia; Gülmez, Şefika; Michalik, Aleksandra; Baranowska, Irena

    2013-08-23

    A new approach based on microextraction by packed sorbent (MEPS) and a reversed-phase ultra-high pressure liquid chromatography (UHPLC) method was developed and validated for the determination and quantification of nonsteroidal anti-inflammatory drugs (NSAIDs) (acetylsalicylic acid, ketoprofen, diclofenac, naproxen and ibuprofen) in human urine. The important factors that could influence the extraction were previously screened using the Plackett-Burman design approach. The optimal MEPS extraction conditions were obtained using C18 phase as a sorbent, small sample volume (20μL) and a short time period (approximately 5min) for the entire sample preparation step. The analytes were separated on a core-shell column (Poroshell 120 EC-C18; 100mm×3.0mm; 2.7μm) using a binary mobile phase composed of aqueous 0.1% trifluoroacetic acid and acetonitrile in the gradient elution mode (4.5min of analysis time). The analytical method was fully validated based on linearity, limits of detection (LOD), limits of quantification (LOQ), inter- and intra-day precision and accuracy, and extraction yield. Under optimised conditions, excellent linearity (R(2)>0.9991), limits of detection (1.07-16.2ngmL(-1)) and precision (0.503-9.15% RSD) were observed for the target drugs. The average absolute recoveries of the analysed compounds extracted from the urine samples were 89.4-107%. The proposed method was also applied to the analysis of NSAIDs in human urine. The new approach offers an attractive alternative for the analysis of selected drugs from urine samples, providing several advantages including fewer sample preparation steps, faster sample throughput and ease of performance compared to traditional methodologies. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Rapid determination of yunaconitine and related alkaloids in aconites and aconite-containing drugs by ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Song, Long; Zhang, Hong; Liu, Xin; Zhao, Zhi-Li; Chen, Shi-Lin; Wang, Zheng-Tao; Xu, Hong-Xi

    2012-12-01

    Yunaconitine (YAC) is a toxic aconite alkaloid that is considered to be a hidden aconite poison since it is frequently found in body fluids from aconite poisoning patients, but has not been well studied in commonly used herbal drugs. In this paper, a rapid and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection combined with microwave-assisted extraction (MAE) was developed for high throughput simultaneous determination of YAC and six other toxic aconite alkaloids in 31 samples of crude, processed aconites and aconite-containing drugs. The optimized method showed excellent linearity, precision, accuracy and recovery for all target compounds with short run time. YAC was detected in some samples with contents from 0.015 to 10.41 mg/g. This is the first report on the determination of YAC in Radix Aconiti, Radix Aconiti Kusnezoffii and aconite-containing drugs. This newly developed method facilitates the rapid screening of YAC and related toxic aconite alkaloids and allows YAC to be used as a chemical marker for the quality control of aconites and aconite-containing drugs. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Determination of Organic Impurities in Anthraquinone Color Additives D&C Violet No. 2 and D&C Green No. 6 by Ultra-High Performance Liquid Chromatography.

    PubMed

    Yang, H H Wendy

    2017-01-01

    A new practical and time-saving ultra-high performance liquid chromatography (UHPLC) method has been developed for determining the organic impurities in the anthraquinone color additives D&C Violet No. 2 and D&C Green No. 6. The impurities determined are p-toluidine, 1-hydroxyanthraquinone, 1,4-dihydroxyanthraquinone, and two subsidiary colors. The newly developed UHPLC method uses a 1.7-μ particle size C-18 column, 0.1 M ammonium acetate and acetonitrile as eluents, and photodiode array detection. For the quantification of the impurities, six-point calibration curves were used with correlation coefficients that ranged from 0.9974 to 0.9998. Recoveries of impurities ranged from 99 to 104%. Relative standard deviations ranged from 0.81 to 4.29%. The limits of detection for the impurities ranged from 0.0067% to 0.216%. Samples from sixteen batches of each color additive were analyzed, and the results favorably compared with the results obtained by gravity-elution column chromatography, thin-layer chromatography, and isooctane extraction. Unlike with those other methods, use of the UHPLC method permits all of the impurities to be determined in a single analysis, while also reducing the amount of organic waste and saving time and labor. The method is expected to be implemented by the U.S. Food and Drug Administration for analysis of color additive samples submitted for batch certification.

  17. Regioisomeric and enantiomeric analyses of 24 designer cathinones and phenethylamines using ultra high performance liquid chromatography and capillary electrophoresis with added cyclodextrins.

    PubMed

    Li, Li; Lurie, Ira S

    2015-09-01

    DESIGNER: phenethylamines (PEAs) and cathinones have been encountered worldwide. Complete characterization of these substances can be challenging due to their chirality and variably substituted phenyl rings. In this study, 24 PEAs and cathinones were analyzed by ultra high performance liquid chromatography with photo diode array detection (UHPLC-PDA) on a variety of stationary phases, and by capillary electrophoresis on a dynamically coated capillary with PDA detection (CE-PDA). In the UHPLC-PDA study, a BEH Phenyl column resolved 18 of the 24 regioisomers in 8min, with good discrimination of the PEAs. In contrast, capillary zone electrophoresis (CZE) on a dynamically coated capillary partially or baseline resolved only 10 of the 24 regioisomers, but with improved discrimination of mono-substituted cathinones. A second series of CE-PDA experiments using 80mM (2-hydroxypropyl)-β-cyclodextrin (HP-β-CD) in the run buffer resolved all 24 regioisomers and all but two sets of enantiomers within 18min. Five illicit samples were successfully analyzed using the described methods. Published by Elsevier Ireland Ltd.

  18. Characterisation of chemical components for identifying historical Chinese textile dyes by ultra high performance liquid chromatography - photodiode array - electrospray ionisation mass spectrometer.

    PubMed

    Han, Jing; Wanrooij, Jantien; van Bommel, Maarten; Quye, Anita

    2017-01-06

    This research makes the first attempt to apply Ultra High Performance Liquid Chromatography (UHPLC) coupled to both Photodiode Array detection (PDA) and Electrospray Ionisation Mass Spectrometer (ESI-MS) to the chemical characterisation of common textile dyes in ancient China. Three different extraction methods, respectively involving dimethyl sulfoxide (DMSO)-oxalic acid, DMSO and hydrochloric acid, are unprecedentedly applied together to achieve an in-depth understanding of the chemical composition of these dyes. The first LC-PDA-MS database of the chemical composition of common dyes in ancient China has been established. The phenomena of esterification and isomerisation of the dye constituents of gallnut, gardenia and saffron, and the dye composition of acorn cup dyed silk are clarified for the first time. 6-Hydroxyrubiadin and its glycosides are first reported on a dyed sample with Rubia cordifolia from China. UHPLC-PDA-ESI-MS with a C18 BEH shield column shows significant advantages in the separation and identification of similar dye constituents, particularly in the cases of analysing pagoda bud and turmeric dyed sample extracts. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Suitability of ultra-high performance liquid chromatography for the determination of fat-soluble nutritional status (vitamins A, E, D, and individual carotenoids).

    PubMed

    Granado-Lorencio, F; Herrero-Barbudo, C; Blanco-Navarro, I; Pérez-Sacristán, B

    2010-06-01

    Our aim was to assess the suitability of ultra-high performance liquid chromatography (UHPLC) for the simultaneous determination of biomarkers of vitamins A (retinol, retinyl esters), E (alpha- and gamma-tocopherol), D (25-OH-vitamin D), and the major carotenoids in human serum to be used in clinical practice. UHPLC analysis was performed on HSS T3 column (2.1 x 100 mm; 1.8 microm) using gradient elution and UV-VIS detection. The system allows the simultaneous determination of retinol, retinyl palmitate, 25-OH-vitamin D, alpha- and gamma-tocopherol, lutein plus zeaxanthin, alpha-carotene, beta-carotene, alpha- and beta-cryptoxanthin and lycopene. The method showed a good linearity over the physiological range with an adequate accuracy in samples from quality control programs. Suitability of the method in clinical practice was tested by analyzing samples (n = 286) from patients. In conclusion, UHPLC constitutes a reliable approach for nutrient/biomarker profiling allowing the rapid, simultaneous and low-cost determination of vitamins A, E, and D (including vitamers and ester forms) and the major carotenoids in clinical practice.

  20. Ultra-high performance liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of five phthalides in rat plasma: Application to a comparative pharmacokinetic study of Huo Luo Xiao Ling Dan and herb-pair extract.

    PubMed

    Ma, Wen; Wang, Weihui; Peng, Yan; Bian, Qiaoxia; Wang, Nannan; Lee, David Y-W; Dai, Ronghua

    2016-06-01

    A fast, sensitive, and reliable ultra-high performance liquid chromatography with tandem mass spectrometry method has been developed and validated for the simultaneous quantitation and pharmacokinetic study of five phthalides (senkyunolide A, ligustilide, butylidenephthalide, 3-butylphthalide, and levistilide A) in rat plasma after oral administration of Huo Luo Xiao Ling Dan (HLXLD) or Angelica sinensis--Ligusticum chuanxiong herb pair (DG-CX) between normal and arthritis rats. After extraction from blood, the analytes and internal standard were subjected to ultra-high performance liquid chromatography with a Shim-pack XR-ODS column (75 × 3.0 mm(2) , 2.2 μm particles) and mobile phase was composed of methanol and water (containing 0.05% formic acid) under gradient elution conditions, with an electrospray ionization source in the positive ionization and multiple reaction monitoring mode. The lower limits of quantification were 0.192-0.800 ng/mL for all the analytes. Satisfactory linearity, precision, accuracy, mean extraction recovery, and acceptable matrix effect have been achieved. The validated method was successfully applied to a comparative pharmacokinetic study of five bioactive components in rat plasma after oral administration of HLXLD or DG-CX alone, respectively, between normal and arthritic rats. The results showed that there were unlike characters of pharmacokinetics among different groups. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Environmental analysis of alcohol ethoxylates and nonylphenol ethoxylate metabolites by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lara-Martín, Pablo A; González-Mazo, Eduardo; Brownawell, Bruce J

    2012-03-01

    Surfactants and their metabolites can be found in aquatic environments at relatively high concentrations compared with other micropollutants due in part to the exceptionally large volumes produced every year. We have focused our attention here on the most widely used nonionic surfactants, alcohol ethoxylates (AEOs), and on nonylphenol ethoxylate (NPEO) degradation products (short-chain nonylphenol ethoxylates, NP1-3EO, nonylphenol, NP, and nonylphenol ethoxycarboxylates, NP1-2EC), which are endocrine-disrupting compounds. Our main objective in this work was to develop a methodology aimed at the extraction, isolation, and improved analysis of these analytes in environmental samples at trace levels. Extraction recoveries of target compounds were determined for sediment samples after ultrasonic extraction and purification using HLB or C18 solid-phase extraction minicolumns. Recovery percentages were usually between 61 and 102% but were lower for longer AEO ethoxymers. Identification and quantification of target compounds was carried out using a novel ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS-MS) approach, a combination that provides higher sensitivity and faster analysis than prior methods using conventional high-performance liquid chromatography-mass spectrometry. Limits of detection were usually below 0.5 ng/g, being higher for monoethoxylate species (>5 ng/g) because of poor ionization. The method was used for analyzing surface sediment samples collected at Jamaica Bay (NY) in 2008. The highest values (28,500 ng/g for NP, 4,200 ng/g for NP1-3EO, 22,400 ng/g for NP1-2EC, and 1,500 ng/g for AEOs) were found in a sampling station from a restricted water circulation area that is heavily impacted by wastewater discharges.

  2. On-line hyphenation of centrifugal partition chromatography and high pressure liquid chromatography for the fractionation of flavonoids from Hippophaë rhamnoides L. berries.

    PubMed

    Michel, Thomas; Destandau, Emilie; Elfakir, Claire

    2011-09-09

    Centrifugal Partition Chromatography (CPC), a liquid-liquid preparative chromatography using two immiscible solvent systems, benefits from numerous advantages for the separation or purification of synthetic or natural products. This study presents the on-line hyphenation of CPC-Evaporative Light Scattering Detector (CPC-ELSD) with High Performance Liquid Chromatography-UV (HPLC-UV) for the fractionation of flavonols from a solvent-free microwave extract of sea buckthorn (Hippophaë rhamnoides L., Elaeagnaceae) berries. An Arizona G system was used for the fractionation of flavonoids by CPC and a fused core Halo C18 column allowed the on-line analyses of collected fractions by HPLC. The on-line CPC/HPLC procedure allowed the simultaneous fractionation step at preparative scale combined with the HPLC analyses which provide direct fingerprint of collected fractions. Thus the crude extract was simplified and immediate information on the composition of fractions could be obtained. Furthermore, this methodology reduced the time of post-fractionation steps and facilitated identification of main molecules by Mass Spectrometry (MS). Rutin, isorhamnetin-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin-3-O-glucoside, isorhamnetin-rhamnoside, quercetin and isorhamnetin were identified. CPC-ELSD/HPLC-UV could be considered as a high-throughput technique for the guided fractionation of bioactive natural products from complex crude extracts. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Metabolic profiling of the hepatotoxicity and nephrotoxicity of Ginkgolic acids in rats using ultra-performance liquid chromatography-high-definition mass spectrometry.

    PubMed

    Qian, Yiyun; Peng, Yunru; Shang, Erxin; Zhao, Ming; Yan, Liang; Zhu, Zhenhua; Tao, Jinhua; Su, Shulan; Guo, Sheng; Duan, Jin-Ao

    2017-08-01

    Ginkgolic acids (GAs) are thought to be the potentially hazardous constituents corresponding to the toxic side effects of Ginkgo products. In this study, toxicological and metabolomics studies of GAs were carried out by ultra-performance liquid chromatography-high-definition mass spectrometry (UPLC-HDMS). Significant changes in serum clinical chemistry were observed in the both low (100 mg/kg) and high (900 mg/kg) doses. Especially the serum enzyme of ALT, AST, LDH, and CK decreased in treated groups. The histopathological observation demonstrated hepatic steatosis in liver and tubular vacuolar degeneration in kidney. These results demonstrated the hepatotoxicity and nephrotoxicity of GAs. Functional disorders are more likely to be toxic induced by GAs. Metabolic profiling within seven days revealed the change of the body status after oral administration. The results indicated the body function was significantly influenced at the 3rd day and could recover in seven days. Metabolomic analysis showed alterations in 14 metabolites from plasma such as LysoPC(18:0), LysoPC(18:2) and other lipids. The results suggested that exposure to GAs could cause disturbances in liver and kidney function associated with the metabolisms of lipids, glucose and the enzyme activity. Copyright © 2017. Published by Elsevier B.V.

  4. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    USDA-ARS?s Scientific Manuscript database

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  5. High pressure liquid chromatographic determination of aflatoxins in spices.

    PubMed

    Awe, M J; Schranz, J L

    1981-11-01

    High pressure liquid chromatography with fluorescence detection is used to determine aflatoxin in 5 common spices. A 10 micrometer microparticulate silica gel column is used with a dichloromethane-cyclohexane-acetonitrile solvent system to resolve aflatoxins B1, G1, B2, and G2. The fluorescence detector contained a silica gel-packed flowcell. Samples of black, white, and red pepper, ginger, and nutmeg were extracted according to a previously published method. Recoveries from aflatoxin-free samples of white pepper, ginger, and red pepper spiked with 1-50 micrograms aflatoxin/kg ranged from 64 to 92%.

  6. Profiling the indole alkaloids in yohimbe bark with ultra-performance liquid chromatography coupled with ion mobility quadrupole time-of-flight mass spectrometry.

    PubMed

    Sun, Jianghao; Baker, Andrew; Chen, Pei

    2011-09-30

    An ultra-performance liquid chromatography/ion mobility quadrupole time-of-flight mass spectrometry (UPLC/IM-QTOF-MS) method was developed for profiling the indole alkaloids in yohimbe bark. Many indole alkaloids with the yohimbine or ajmalicine core structure, plus methylated, oxidized and reduced species, were characterized. Common fragments and mass differences are described. It was shown that the use of IMS could provide another molecular descriptor, i.e. molecular shape by rotationally averaged collision cross-section; this is of great value for identification of constituents when reference materials are usually not available. Using the combination of high resolution (~40000) accurate mass measurement with time-aligned parallel (TAP) fragmentation, MS(E) (where E represents collision energy), ion mobility mass spectrometry (IMS) and UPLC chromatography, a total 55 indole alkaloids were characterized and a few new indole alkaloids are reported for the first time. Published in 2011 by John Wiley & Sons, Ltd.

  7. Liquid Crystals in Chromatography

    NASA Astrophysics Data System (ADS)

    Witkiewicz, Zygfryd

    The following sections are included: * INTRODUCTION * LIQUID CRYSTALS SUITABLE FOR GAS CHROMATOGRAPHY * Monomeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Conventional Analytical Columns * Capillary Columns * FACTORS AFFECTING THE CHROMATOGRAPHIC SEPARATIONS ON LIQUID CRYSTAL STATIONARY PHASES * Kind of Mesophase of the Liquid Crystal * Molecular Structure of the Liquid Crystals and of the Chromatographed Substances * Substrate on which the Liquid Crystal is Deposited * ANALYTICAL APPLICATIONS OF LIQUID CRYSTAL STATIONARY PHASES IN GAS CHROMATOGRAPHY * Separation of Isomers of Benzene and Naphthalene Derivatives * Separation of Alkane and Alkene Isomers * Separation of Mixtures of Benzene and Aliphatic Hydrocarbon Derivatives Containing Heteroatoms * Separation of Polynuclear Hydrocarbons * INVESTIGATION OF THE PROPERTIES OF LIQUID CRYSTALS BY GAS CHROMATOGRAPHY * APPLICATION OF LIQUID CRYSTALS IN LIQUID CHROMATOGRAPHY * Column Chromatography * Thin-Layer Chromatography * APPLICATION OF LIQUID CRYSTAL STATIONARY PHASES IN SUPERCRITICAL FLUID CHROMATOGRAPHY * FINAL REMARKS * References

  8. High pressure liquid level monitor

    DOEpatents

    Bean, Vern E.; Long, Frederick G.

    1984-01-01

    A liquid level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.

  9. Simultaneous determination of 12 pharmaceuticals in water samples by ultrasound-assisted dispersive liquid-liquid microextraction coupled with ultra-high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Guan, Jin; Zhang, Chi; Wang, Yang; Guo, Yiguang; Huang, Peiting; Zhao, Longshan

    2016-11-01

    A new analytical method was developed for simultaneous determination of 12 pharmaceuticals using ultrasound-assisted dispersive liquid-liquid microextraction (DLLME) followed by ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). Six nonsteroidal anti-inflammatory drugs (NSAIDs, ketoprofen, mefenamic acid, tolfenamic acid, naproxen, sulindac, and piroxicam) and six antibiotics (tinidazole, cefuroxime axetil, ciprofloxacin, sulfamethoxazole, sulfadiazine, and chloramphenicol) were extracted by ultrasound-assisted DLLME using dichloromethane (800 μL) and methanol/acetonitrile (1:1, v/v, 1200 μL) as the extraction and dispersive solvents, respectively. The factors affecting the extraction efficiency, such as the type and volume of extraction and dispersive solvent, vortex and ultrasonic time, sample pH, and ionic strength, were optimized. The ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution by using a small volume of dispersive solvent, which increased the extraction efficiency and reduced the equilibrium time. Under the optimal conditions, the calibration curves showed good linearity in the range of 0.04-20 ng mL -1 (ciprofloxacin and sulfadiazine), 0.2-100 ng mL -1 (ketoprofen, tinidazole, cefuroxime axetil, naproxen, sulfamethoxazole, and sulindac), and 1-200 ng mL -1 (mefenamic acid, tolfenamic acid, piroxicam, and chloramphenicol). The LODs and LOQs of the method were in the range of 0.006-0.091 and 0.018-0.281 ng mL -1 , respectively. The relative recoveries of the target analytes were in the range from 76.77 to 99.97 % with RSDs between 1.6 and 8.8 %. The developed method was successfully applied to the extraction and analysis of 12 pharmaceuticals in five kinds of water samples (drinking water, running water, river water, influent and effluent wastewater) with satisfactory results. Graphical Abstract Twelve pharmaceuticals in water samples analyted by UHPLC

  10. A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients.

    PubMed

    Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako

    2016-08-01

    A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all <7.1%. The accuracy varied from -0.7 to 8.2%. The developed UHPLC-MS/MS method was successfully applied to determine plasma biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Metabolite identification and pharmacokinetic profiling of PP242, an ATP-competitive inhibitor of mTOR using ultra high-performance liquid chromatography and mass spectrometry.

    PubMed

    Rashid, Md Mamunur; Lee, Hyunbeom; Jung, Byung Hwa

    2018-01-01

    PP242 is a second generation novel selective ATP-competitive inhibitor of mTOR that displayed promising anti-cancer activity over several cancer types by inhibiting both the complexes of mTOR (mTORC1 and mTORC2). The purpose of this study is to identify the possible metabolites and to evaluate the pharmacokinetic profile of PP242 after a single oral administration to Sprague-Dawley (SD) rats. Two metabolites, including one phase I and one phase II, were identified by in vitro and in vivo studies using rat liver microsomes (RLMs) as well as rat plasma, urine and feces, respectively, through ultra high-performance liquid chromatography-linear ion trap quadrupole-orbitrap-mass spectrometry (UHPLC-LTQ-Orbitrap-MS). The major biotransformation pathways of PP242 were hydroxylation and glucuronide conjugation. Additionally, a simple and rapid quantification method was developed and validated. The method recovery was within 79.7-84.6%, whereas the matrix effect was 78.1-96.0% in all three quality control (QC) concentrations (low, medium and high) including the LLOQ. Other parameters showed acceptable results according to the US food and drug administration (FDA) guidelines for bioanalytical method validation. Afterwards, pharmacokinetic parameters were evaluated in rat plasma by successfully applying the validated method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). After a single oral administration at a dose of 5mg/kg, the maximum plasma concentration (C max ) of PP242 was 0.17±0.08μg/mL, while the elimination was moderately fast (T 1/2 : 172.18±45.54min). All of the obtained information on the metabolite identification and pharmacokinetic parameter elucidation could facilitate the further development of PP242. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Identification of metabolites of vindoline in rats using ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Zhang, Yuqian; Sun, Yupeng; Mu, Xiyan; Yuan, Lin; Wang, Qiao; Zhang, Lantong

    2017-08-15

    Vindoline (VDL) is an indole alkaloid, possessing hypoglycemic and vasodilator effects, and it is also the prodrug of many vinca alkaloids. In this paper, we analyzed in vivo (including plasma, urine, bile and faeces) and in vitro metabolic profile of VDL in rat with ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UHPLC-Q-TOF-MS/MS). The chromatographic separation was performed on a C 18 column with a mobile phase consisted of 3mM ammonium acetate buffer and acetonitrile at a flow rate of 300μL/min. The mass spectral analysis was conducted in a positive electrospray ionization mode, and on-line data acquisition method multiple mass defect filter (MMDF) combined with dynamic background subtraction (DBS) were used in the biological samples analysis to trace all the potential metabolites of VDL. Twenty-five metabolites of VDL were detected by comparing with the blank sample, of which there were 2 sulfate conjugates. These data suggested that the biotransformation of VDL was deacetylation, oxidation, deoxidization, methylation, dealkylation and sulfate conjugation. This study provides useful information for further study of the pharmacology and mechanism of VDL, meanwhile, the research method can be widely applied to speculate structural features of the metabolites of other vinca alkaloids. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analysis of microdialysate monoamines, including noradrenaline, dopamine and serotonin, using capillary ultra-high performance liquid chromatography and electrochemical detection.

    PubMed

    Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine

    2014-03-01

    Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The challenges of developing a generic extraction procedure to analyze multi-class veterinary drug residues in milk and honey using ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, Jian; Leung, Daniel

    2012-08-01

    This paper discusses the analytical challenges to develop a generic extraction procedure to analyze or screen multi-class veterinary drugs in milk and honey using ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC QqTOF MS). The veterinary drugs in this study included aminoglycosides, endectocides, fluoroquinolones, ionophores, β-lactams or penicillins, macrolides, NSAIDs, phenicols, sulfonamides and tetracyclines. Veterinary drugs were extracted using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, which entailed the use of acetonitrile containing 1% acetic acid, sodium acetate, ethylenediaminetetra acetic acid disodium (EDTA) and magnesium sulfate, and no clean-up was performed. Chromatographic separation was achieved on a reversed-phase Acquity UPLC BEH C(18) , 100 × 2.1 mm, 1.7 µm column with 0.1% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. Due to poor chromatographic retention, aminoglycosides were first dropped from the list, and because of poor extractability, β-lactams and tetracyclines were also excluded from the method. The method was able to quantify 31 or screen up to 54 drugs (unbound) in honey, and to quantify 34 or screen up to 59 drugs in milk. UHPLC QqTOF data were acquired in TOF MS full-scan mode that allowed both quantification and confirmation of veterinary drugs and identification of their degradation products in samples. The method could achieve detection limits as low as 1 µg/kg with analytical range from 1 to 100 µg/kg. The developed method was intended to be used for screening of as many analytes as possible in one single analysis, or unequivocal confirmation of positive findings and degradation product identification based on accurate mass measurement and isotopic patterns. © Her Majesty the Queen in Right of Canada 2012. Reproduced with the permission of the Minister of Agriculture.

  15. Magnetic molecularly imprinted polymers for the determination of β-agonist residues in milk by ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Liu, Hongcheng; Lin, Xin; Lin, Tao; Zhang, Yulong; Luo, Yinglan; Li, Qiwan

    2016-09-01

    A simple, accurate, and highly sensitive analytical method was developed in this study for the determination of nine β-agonists in milk. In this method, a new magnetic adsorbent of molecularly imprinted polymers/magnetic nanoparticles prepared by simple physical blending was adopted, which enabled magnetic solid-phase extraction. Thus, the resultant material can be separated from the solvent rapidly and conveniently by a magnet. Two kinds of molecularly imprinted polymer/magnetic nanoparticles materials were fabricated, and the characteristics of materials such as the ratio, pH, amount, desorption, and regeneration were investigated. The analytes were quantified by ultra high performance liquid chromatography coupled to an electrospray ionization tandem mass spectrometer operating in multiple reaction monitoring modes. The detection limit of the method was 0.003-0.3 μg/L, and the detection capability was 0.01-0.3 μg/L. The recoveries of these compounds were 65.7-114% at three spiked levels. Reproducibility represented by relative standard deviation was 11.2% or less. The method was successfully applied to the screening of real samples obtained from local markets and confirmation of the suspected target analytes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Analysis of triacylglycerols on porous graphitic carbon by high temperature liquid chromatography.

    PubMed

    Merelli, Bérangère; De Person, Marine; Favetta, Patrick; Lafosse, Michel

    2007-07-20

    The retention behaviour of several triacylglycerols (TAGs) and fats on Hypercarb, a porous graphitic carbon column (PGC), was investigated in liquid chromatography (LC) under isocratic elution mode with an evaporative light scattering detector (ELSD). Mixtures of chloroform/isopropanol were selected as mobile phase for a suitable retention time to study the influence of temperature. The retention was different between PGC and non-aqueous reversed phase liquid chromatography (NARP-LC) on octadecyl phase. The retention of TAGs was investigated in the interval 30-70 degrees C. Retention was greatly affected by temperature: it decreases as the column temperature increases. Selectivity of TAGs was also slightly influenced by the temperature. Moreover, this chromatographic method is compatible with a mass spectrometer (MS) detector by using atmospheric pressure chemical ionisation (APCI): same fingerprints of cocoa butter and shea butter were obtained with LC-ELSD and LC-APCI-MS. These preliminary results showed that the PGC column could be suitable to separate quickly triacylglycerols in high temperature conditions coupled with ELSD or MS detector.

  17. Behavior of macroporous vinyl silica and silica monolithic columns in high pressure gas chromatography.

    PubMed

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antionali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2017-06-30

    80% vinyltrimethoxysilane-based hybrid silica monoliths (80-VTMS), which have been initially developed for separation in reversed-phase liquid chromatography, have been investigated in high pressure gas chromatography separations (carrier gas pressure up to 60bar) and compared to silica monolithic columns. The behavior of both silica and 80-VTMS monolithic columns was investigated using helium, nitrogen and carbon dioxide as carrier gas. The efficiency of 80-VTMS monolithic columns was shown to vary differently than silica monolithic columns according to the temperature and the carrier gas used. Carrier gas nature was a significant parameter on the retention for both silica and vinyl columns in relation to its adsorption onto the stationary phase in such high pressure conditions. The comparison of retention and selectivity between 80-VTMS monoliths and silica was performed under helium using the logarithm of the retention factor according to the number of carbon atoms combined to Kovats indexes. The very good performances of these columns were demonstrated, allowing the separation of 8 compounds in less than 1min. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A semi-automatic microextraction in packed sorbent, using a digitally controlled syringe, combined with ultra-high pressure liquid chromatography as a new and ultra-fast approach for the determination of prenylflavonoids in beers.

    PubMed

    Gonçalves, João L; Alves, Vera L; Rodrigues, Fátima P; Figueira, José A; Câmara, José S

    2013-08-23

    In this work a highly selective and sensitive analytical procedure based on semi-automatic microextraction by packed sorbents (MEPS) technique, using a new digitally controlled syringe (eVol(®)) combined with ultra-high pressure liquid chromatography (UHPLC), is proposed to determine the prenylated chalcone derived from the hop (Humulus lupulus L.), xanthohumol (XN), and its isomeric flavonone isoxanthohumol (IXN) in beers. Extraction and UHPLC parameters were accurately optimized to achieve the highest recoveries and to enhance the analytical characteristics of the method. Important parameters affecting MEPS performance, namely the type of sorbent material (C2, C8, C18, SIL, and M1), elution solvent system, number of extraction cycles (extract-discard), sample volume, elution volume, and sample pH, were evaluated. The optimal experimental conditions involves the loading of 500μL of sample through a C18 sorbent in a MEPS syringe placed in the semi-automatic eVol(®) syringe followed by elution using 250μL of acetonitrile (ACN) in a 10 extractions cycle (about 5min for the entire sample preparation step). The obtained extract is directly analyzed in the UHPLC system using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and ACN (eluent B) in the gradient elution mode (10min total analysis). Under optimized conditions good results were obtained in terms of linearity within the established concentration range with correlation coefficients (R) values higher than 0.986, with a residual deviation for each calibration point below 12%. The limit of detection (LOD) and limit of quantification (LOQ) obtained were 0.4ngmL(-1) and 1.0ngmL(-1) for IXN, and 0.9ngmL(-1) and 3.0ngmL(-1) for XN, respectively. Precision was lower than 4.6% for IXN and 8.4% for XN. Typical recoveries ranged between 67.1% and 99.3% for IXN and between 74.2% and 99.9% for XN, with relative standard deviations %RSD no larger than 8%. The applicability of the proposed analytical

  19. Quantification of patulin in fruit leathers by ultra-high-performance liquid chromatography-photodiode array (UPLC-PDA).

    PubMed

    Maragos, Chris M; Busman, Mark; Ma, Liang; Bobell, John

    2015-01-01

    Patulin is a mycotoxin commonly found in certain fruit and fruit products. For this reason many countries have established regulatory limits pertaining to, in particular, apple juice and apple products. Fruit leathers are produced by dehydrating fruit puree, leaving a sweet product that has a leathery texture. A recent report in the literature described the detection of patulin at substantial levels in fruit leathers. To investigate this further, an ultra-high-performance liquid chromatography-photodiode array (UPLC-PDA) method was developed for the sensitive detection of patulin in fruit leathers. Investigations were also made of the suitability of direct analysis in real time-mass spectrometry (DART-MS) for detection of patulin from the surface of fruit leathers. Results indicated DART-MS was insufficiently sensitive for quantification from the surface of home-style apple leathers, although patulin spiked onto the surface of leather or peel could be detected. The UPLC-PDA method was used to determine the fate of patulin during the preparation of home-made fruit leathers. Interestingly, when a home-style process was used, the patulin was not destroyed, but rather increased in concentration as the puree was dehydrated. The UPLC-PDA method was also used to screen for patulin in commercial fruit leathers. Of the 36 products tested, 14 were above the limit of detection (3.5 μg kg(-1)) and nine were above the limit of quantification (12 μg kg(-1)). Positive samples were confirmed by UPLC-MS/MS. Only one sample was found above the US regulatory limit for single-strength apple juice products (50 μg kg(-1)). These results suggest patulin can be concentrated during preparation and can be found in fruit leathers. The limited survey suggests that patulin is fairly prevalent in such commercial products, but that the levels are usually low.

  20. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    PubMed

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  1. A new combined method of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in rat brain microdialysates by ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Zheng, Longfang; Zhao, Xian-En; Zhu, Shuyun; Tao, Yanduo; Ji, Wenhua; Geng, Yanling; Wang, Xiao; Chen, Guang; You, Jinmao

    2017-06-01

    In this work, for the first time, a new hyphenated technique of stable isotope-labeling derivatization-ultrasound-assisted dispersive liquid-liquid microextraction has been developed for the simultaneous determination of monoamine neurotransmitters (MANTs) and their biosynthesis precursors and metabolites. The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry detection using multiple-reaction monitoring mode. A pair of mass spectrometry sensitizing reagents, d 0 -10-methyl-acridone-2-sulfonyl chloride and d 3 -10-methyl-acridone-2-sulfonyl chloride, as stable isotope probes was utilized to facilely label neurotransmitters, respectively. The heavy labeled MANTs standards were prepared and used as internal standards for quantification to minimize the matrix effects in mass spectrometry analysis. Low toxic bromobenzene (extractant) and acetonitrile (dispersant) were utilized in microextraction procedure. Under the optimized conditions, good linearity was observed with the limits of detection (S/N>3) and limits of quantification (S/N>10) in the range of 0.002-0.010 and 0.015-0.040nmol/L, respectively. Meanwhile, it also brought acceptable precision (4.2-8.8%, peak area RSDs %) and accuracy (recovery, 96.9-104.1%) results. This method was successfully applied to the simultaneous determination of monoamine neurotransmitters and their biosynthesis precursors and metabolites in rat brain microdialysates of Parkinson's disease and normal rats. This provided a new method for the neurotransmitters related studies in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Improving liquid chromatography-mass spectrometry sensitivity using a subambient pressure ionization with nanoelectrospray (SPIN) interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Keqi; Page, Jason S.; Marginean, Ioan

    2011-04-22

    In this work the Subambient Pressure Ionization with Nanoelectrospray (SPIN) ion source and interface which operates at ~15-30 Torr is demonstrated to be compatible with gradient reversed-phase liquid chromatography-MS applications, exemplified here with the analysis of complex samples (a protein tryptic digest and a whole cell lysate). A low liquid chromatographic flow rate (100-400 nL/min) allowed stable electrospray to be established while avoiding electrical breakdown. Efforts to increase the operating pressure of the SPIN source relative to previously reported designs prevented solvent freezing and enhanced charged cluster/droplet desolvation. A 5-12-fold improvement in sensitivity relative to a conventional atmospheric pressure nanoelectrospraymore » ionization (ESI) source was obtained for detected peptides.« less

  3. Mallow carotenoids determined by high-performance liquid chromatography

    USDA-ARS?s Scientific Manuscript database

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  4. Effect of ultra high pressure homogenization treatment on the bioactive compounds of soya milk.

    PubMed

    Toro-Funes, N; Bosch-Fusté, J; Veciana-Nogués, M T; Vidal-Carou, M C

    2014-01-01

    Ultra high pressure homogenization (UHPH) is a useful novel technology to obtain safe and high-quality liquid foods. The effect of UHPH at 200 and 300 MPa in combination with different inlet temperatures (Tin) (55, 65 and 75 °C) on the bioactive compounds of soya milk was studied. Total phytosterols increased with the higher combination of pressure and temperature. The main phytosterol was β-sitosterol, followed by stigmasterol and campesterol. Total tocopherols in UHPH-treated soya milks decreased as the temperature and pressure increased. UHPH treatment also affected the different chemical forms of tocopherols. No biogenic amines were detected in any of the analyzed soya milks. Meanwhile, the polyamines SPD and SPM were found in all soya milks, being stable to the UHPH treatment. Total isoflavones increased with the higher combination of pressure and temperature. No differences in the isoflavone profile were found, with β-glucoside conjugates being the predominant form. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Pressure sensor for high-temperature liquids

    DOEpatents

    Forster, George A.

    1978-01-01

    A pressure sensor for use in measuring pressures in liquid at high temperatures, especially such as liquid sodium or liquid potassium, comprises a soft diaphragm in contact with the liquid. The soft diaphragm is coupled mechanically to a stiff diaphragm. Pressure is measured by measuring the displacment of both diaphragms, typically by measuring the capacitance between the stiff diaphragm and a fixed plate when the stiff diaphragm is deflected in response to the measured pressure through mechanical coupling from the soft diaphragm. Absolute calibration is achieved by admitting gas under pressure to the region between diaphragms and to the region between the stiff diaphragm and the fixed plate, breaking the coupling between the soft and stiff diaphragms. The apparatus can be calibrated rapidly and absolutely.

  6. Determination of miloxacin and metabolites in human serum and urine by high-pressure liquid chromatography.

    PubMed Central

    Yoshitake, A; Kawahara, K; Shono, F; Umeda, I; Izawa, A; Komatsu, T

    1980-01-01

    A sensitive and reliable high-pressure liquid chromatography (HPLC) assay for miloxacin and its two principal metabolites, 5,8-dihydro-8-oxo-2H-1,3-dioxolo[4,5-g]quinoline-7-carboxylic acid (M-1) and 1,4-dihydro-1,6-dimethoxy-7-hydroxy-4-oxoquinoline-3-carboxylic acid (M-2), in human serum and urine was developed. A strong anion-exchange Zipax SAX column using a mobile phase of 0.01 M citric acid solution containing 0.03 M sodium nitrate with pH 5.0 was used to achieve separation of the three compounds. The retention times of miloxacin, M-1, and M-2 were 3.8, 9.3, and 5.9 min, respectively. Serum and urine concentrations of these compounds as low as 10 ng/ml were measured. When results from the HPLC assay were compared with those from the microbiological assay of serum and urine samples from human subjects receiving miloxacin orally, the correlation coefficients were 0.94 for the serum and 0.99 for the urine. The HPLC assay method presents an alternative to the microbiological assay and permits future pharmacokinetic investigations of miloxacin. PMID:7416751

  7. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with the pressurized liquid extraction for the quantification and confirmation of sulfonamides in the foods of animal origin.

    PubMed

    Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui

    2011-09-01

    The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences

  8. Field Evaluation of Ultra-High Pressure Water Systems for Runway Rubber Removal

    DTIC Science & Technology

    2014-04-01

    ER D C/ G SL T R- 14 -1 1 Field Evaluation of Ultra-High Pressure Water Systems for Runway Rubber Removal G eo te ch ni ca l a nd S tr...Field Evaluation of Ultra-High Pressure Water Systems for Runway Rubber Removal Aaron B. Pullen Applied Research Associates, Inc. 421 Oak Avenue...collaboration with Applied Research Associates, Inc. (ARA). Several types of commercial UHPW water blasting systems were tested on an ungrooved portland cement

  9. A sensitive microextraction by packed sorbent-based methodology combined with ultra-high pressure liquid chromatography as a powerful technique for analysis of biologically active flavonols in wines.

    PubMed

    Silva, Catarina L; Gonçalves, João L; Câmara, José S

    2012-08-20

    A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250μL) in five extraction cycle and in a short time period (about 5min for the entire sample preparation step). Under optimized conditions, excellent linearity (R(values)(2)>0.9963), limits of detection of 0.006μgmL(-1) (quercetin) to 0.013μgmL(-1) (myricetin) and precision within 0.5-3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0-97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8±3.7μgmL(-1)). Quercetin (0.97±0.41μgmL(-1)) and kaempferol (0.66±0.24μgmL(-1)) were found in a lower concentration. The optimized MEPS(C8) method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPS(C8) approach offers an attractive alternative for analysis of flavonols in wines, providing a number of

  10. Determination of perfluorocompounds in popcorn packaging by pressurised liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Martínez-Moral, María Pilar; Tena, María Teresa

    2012-11-15

    The development and characterisation of a method based on reverse-phase ultra-performance liquid chromatography (UPLC) coupled to a quadrupole-time of flight mass spectrometer (Q-TOF-MS) with negative electrospray ionisation (ESI) to determine perfluorinated compounds (PFCs) in packaging is presented in this paper. Analytes were quantitatively recovered from packaging with methanol in only one PLE cycle of 6 min at 100 °C. The UPLC allowed the successful separation of the studied PFCs in less than 4 min. The whole method presented good precision, with RSDs below 8%, LODs from 0.6 to 16 ng g(-1); and excellent recovery values, around 100% in all cases, were achieved. The PLE-UPLC-MS method was applied to the analysis of popcorn packaging for microwave cooking. Besides the most commonly studied PFCs: PFOA and PFOS, the presence of other perfluorocarboxylic acids (PFCAs) in popcorn packaging is evidenced in this work. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Sensitive analysis of blonanserin, a novel antipsychotic agent, in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi

    2010-01-01

    A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  12. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...

  13. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...

  14. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...

  15. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...

  16. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...

  17. Panax ginseng Adventitious Root Suspension Culture: Protocol for Biomass Production and Analysis of Ginsenosides by High Pressure Liquid Chromatography.

    PubMed

    Murthy, Hosakatte Niranjana; Paek, Kee Yoeup

    2016-01-01

    Panax ginseng C.A. Meyer (Korean ginseng) is a popular herbal medicine. It has been used in Chinese and Oriental medicines since thousands of years. Ginseng products are generally used as a tonic and an adaptogen to resist the adverse influence of a wide range of physical, chemical and biological factors, and to restore homeostasis. Ginsenosides or ginseng saponins are the principal active ingredients of ginseng. Since ginseng cultivation process is very slow and needs specific environment for field cultivation, cell and tissue cultures are sought as alternatives for the production of ginseng biomass and bioactive compounds. In this chapter, we focus on methods of induction of adventitious roots from ginseng roots, establishment of adventitious root suspension cultures using bioreactors, procedures for processing of adventitious roots, and analysis of ginsenosides by high pressure liquid chromatography.

  18. Fast analysis of triterpenoids in Ganoderma lucidum spores by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry.

    PubMed

    Yan, Zhou; Xia, Bing; Qiu, Ming Hua; Li Sheng, Ding; Xu, Hong Xi

    2013-11-01

    A rapid and reliable method was established for simultaneous determination of main triterpenoids in Ganoderma lucidum spores using ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-TQ-MS). The established method was validated in terms of linearity, sensitivity, precision, accuracy and stability, and was successfully applied to determine the contents of 10 main triterpenoids in different batches of G. lucidum spores. The analysis results showed that moderate levels of triterpenoids were found in G. lucidum spores. In addition, a MS full scan with a daughter ion scan experiment was performed to identify the potential derivatives of triterpenoids present in G. lucidum spores. As a result, a total of 22 triterpenoids from different G. lucidum spores were unequivocally or tentatively identified via comparisons with authentic standards and literatures. This method provides both qualitative and quantitative results without the need for repetitive UPLC-MS analyses, thereby increasing efficiency and productivity, making it suitable for high-throughput applications. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Analysis of perfluorinated chemicals in umbilical cord blood by ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Lien, Guang-Wen; Wen, Ting-Wen; Hsieh, Wu-Shiun; Wu, Kuen-Yuh; Chen, Chia-Yang; Chen, Pau-Chung

    2011-03-15

    Perfluorinated compounds (PFCs) can cross the placental barrier and enter fetal circulation. This study aimed at developing a fast and sensitive ultra-high performance liquid chromatography/tandem mass spectrometry method for the determination of twelve perfluorinated compounds in cord blood. Samples were processed with protein precipitation using formic acid and methanol, mixed with stable isotope labeled standard, followed by sonication and centrifugation, and were analyzed using a Waters ACQUITY UPLC coupled with a Waters Quattro Premier XE triple-quadrupole mass spectrometer. The instrument was operated in selected reaction monitoring (SRM) with negative electrospray ionization. Using BEH C(18) column (2.1 mm×50 mm, 1.7 μm) with 10-mM N-methylmorpholine/methanol gradient elution provided a fast chromatographic separation (5.5 min) and sharp peaks. Intra- and inter-day calibration bias was less than 7% and intra- and inter-day calibration of relative standard deviations were within 0.02-8.22% for all the analytes and concentrations. The recoveries of PFCs spiked into bovine serum ranged from 85 to 104% with relative standard deviations from 0.02 to 6.37%. The limits of quantitation (LOQs), defined as a signal-to-noise ratio of ten, ranged from 0.15 to 3.1 ng/mL for the twelve PFCs. Perfluorooctanoic acid (PFOA), perfluorooctyl sulfonate (PFOS), perfluoroundecanoic acid (PFUA) and perfluorononanoic acid (PFNA) were detected in up to 68% of umbilical cord plasma (n=444) in Taiwan Birth Panel Study and the health effect of these chemicals on children developmental deserves further investigation. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Ultra-preconcentration and determination of selected pharmaceutical and personal care products in different water matrices by solid-phase extraction combined with dispersive liquid-liquid microextraction prior to ultra high pressure liquid chromatography tandem mass spectrometry analysis.

    PubMed

    Celano, Rita; Piccinelli, Anna Lisa; Campone, Luca; Rastrelli, Luca

    2014-08-15

    Pharmaceutical and personal care products (PPCPs) are one of the most important classes of emerging contaminants. The potential of ecological and environmental impacts associated with PPCPs are of particular concern because they continually penetrate the aquatic environment. This work describes a novel ultra-preconcentration technique for the rapid and highly sensitive analysis of selected PPCPs in environmental water matrices at ppt levels. Selected PPCPs were rapidly extracted and concentrated from large volumes of aqueous solutions (500 and 250mL) by solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) and then analyzed using UHPLC-MS/MS. Experimental parameters were carefully investigated and optimized to achieve the best SPE-DLLME efficiency and higher enrichment factors. The best results were obtained using the ternary mixture acetonitrile/methanol/dichloromethane 3:3:4, v/v/v, both as SPE eluent and DLLME extractant/dispersive mixture. DLLME aqueous solution (5% NaCl, 10mgL(-1) TBAB) was also modified to improve the extraction efficiency of more hydrophilic PPCPs. Under the optimal conditions, an exhaustive extraction for most of the investigated analytes (recoveries >70%), with a precision (RSD <10%) and very high enrichment factors were attained for different aqueous matrices (drinking, sea, river and wastewater). Method detection and quantification limits were at very low ppt levels and below 1 and 3ngL(-1), respectively, for 15 of selected PPCPs. The proposed analytical procedure offers numerous advantages such as the simplicity of operation, rapidity, a high enrichment factor and sensitivity. So it is suitable for monitoring and studies of occurrence of PPCPs in different environmental compartments. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Flavor characterization of sugar-added pennywort (Centella asiatica L.) juices treated with ultra-high pressure and thermal processes.

    PubMed

    Apichartsrangkoon, Arunee; Wongfhun, Pronprapa; Gordon, Michael H

    2009-01-01

    The flavor characteristics of pennywort juices with added sugar treated by ultra-high pressure, pasteurization, and sterilization were investigated using solid phase microextraction combined with gas chromatography-mass spectrometry. It was found that sesquiterpene hydrocarbons comprised the major class of volatile components present and the juices had a characteristic aroma due to the presence of volatiles including beta-caryophyllene and humulene and alpha-copaene. In comparison with heated juices, HPP-treated samples could retain more volatile compounds such as linalool and geraniol similar to those present in fresh juice, whereas some volatiles such as alpha-terpinene and ketone class were apparently formed by thermal treatment. All processing operations produced juice that was not significantly different in the concentration of total volatiles. Practical Application: Pennywort juice is considered a nutraceutical drink for health benefits. Therefore, to preserve all aroma and active components in this juice, a nonthermal process such as ultra-high pressure should be a more appropriate technique for retention of its nutritive values than pasteurization and sterilization.

  3. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Recent advances in capillary ultrahigh pressure liquid chromatography.

    PubMed

    Blue, Laura E; Franklin, Edward G; Godinho, Justin M; Grinias, James P; Grinias, Kaitlin M; Lunn, Daniel B; Moore, Stephanie M

    2017-11-10

    In the twenty years since its initial demonstration, capillary ultrahigh pressure liquid chromatography (UHPLC) has proven to be one of most powerful separation techniques for the analysis of complex mixtures. This review focuses on the most recent advances made since 2010 towards increasing the performance of such separations. Improvements in capillary column preparation techniques that have led to columns with unprecedented performance are described. New stationary phases and phase supports that have been reported over the past decade are detailed, with a focus on their use in capillary formats. A discussion on the instrument developments that have been required to ensure that extra-column effects do not diminish the intrinsic efficiency of these columns during analysis is also included. Finally, the impact of these capillary UHPLC topics on the field of proteomics and ways in which capillary UHPLC may continue to be applied to the separation of complex samples are addressed. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Urinary metabolomic study of non-small cell lung carcinoma based on ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Wu, Qian; Wang, Yan; Gu, Xue; Zhou, Junyi; Zhang, Huiping; Lv, Wang; Chen, Zhe; Yan, Chao

    2014-07-01

    Metabolic profiles from human urine reveal the significant difference of carnitine and acylcarnitines levels between non-small cell lung carcinoma patients and healthy controls. Urine samples from cancer patients and healthy individuals were assayed in this metabolomic study using ultra high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry. The data were normalized by the sum of all intensities and creatinine calibration, respectively, before orthogonal partial least squares discriminant analysis. Twenty differential metabolites were identified based on standard compounds or tandem mass spectrometry fragments. Among them, some medium-/long-chain acylcarnitines, for example, cis-3,4-methylene heptanoylcarnitine, were found to be downregulated while carnitine was upregulated in urine samples from the cancer group compared to the control group. Receiver operating characteristic analysis of the two groups showed that the area under curve for the combination of carnitine and 11 selected acylcarnitines was 0.958. This study suggests that the developed carnitine and acylcarnitines profiling method has the potential to be used for screening non-small cell lung carcinoma. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. High-pressure liquid chromatographic analysis of pramoxine hydrochloride in high lipoid aerosol foam dosage form.

    PubMed

    Weinberger, R; Mann, B; Posluszny, J

    1980-04-01

    A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.

  7. Liquid microjunction surface sampling coupled with high-pressure liquid chromatography-electrospray ionization-mass spectrometry for analysis of drugs and metabolites in whole-body thin tissue sections.

    PubMed

    Kertesz, Vilmos; Van Berkel, Gary J

    2010-07-15

    In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, two isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent. The ability to directly and efficiently sample from thin tissue sections via a liquid extraction and then perform a subsequent liquid phase separation increases the utility of this liquid extraction surface sampling approach.

  8. Rapid and Sensitive Quantification of Ursolic Acid and Oleanolic Acid in Human Plasma Using Ultra-performance Liquid Chromatography-Mass Spectrometry.

    PubMed

    Stebounova, Larissa; Ebert, Scott M; Murry, Logan T; Adams, Christopher M; Murry, Daryl J

    2018-04-26

    Ultra-performance liquid chromatography (UPLC) interfaced with atmospheric pressure chemical ionization mass-spectrometry was used to separate and quantify ursolic acid (UA) and oleanolic acid (OA) in human plasma. UA and OA were extracted from 0.5 mL human plasma using supported liquid extraction and separated utilizing an Acquity UPLC HSS column. The method has been validated for both UA and OA quantitation with a limit of detection of 0.5 ng/mL. The UPLC separations are carried out with isocratic elution with methanol and 5 mM ammonium acetate in water (85:15) as a mobile phase at a flow rate of 0.4 mL/min. The assay was linear from 1 ng/mL to 100 ng/mL for both analytes. The total analysis time was 7 min with the retention times of 3.25 (internal standard), 3.65 (UA) and 3.85 min (OA). Recovery of drug from plasma ranged from 70% to 115%. Analysis of quality control samples at 3, 30 and 80 ng/mL (n = 14) had an intra-day coefficient of variation of 9.9%, 4.3% and 5.5%, respectively. A proof-of-concept study in human patients who consumed apple peels indicates that this analytical method could be applied to clinical studies of UA and/or OA in human subjects.

  9. Determination of enantiomeric vigabatrin by derivatization with diacetyl-l-tartaric anhydride followed by ultra-high performance liquid chromatography-quadrupole-time-of-flight mass spectrometry.

    PubMed

    Zhao, Jing; Shin, Yujin; Jin, Yan; Jeong, Kyung Min; Lee, Jeongmi

    2017-01-01

    Vigabatrin, one of the most widely used antiepileptic drugs, is marketed and administered as a racemic mixture, while only S-enantiomer is therapeutically effective. In the present study, diacetyl-l-tartaric acid anhydride was used as an inexpensive and effective chiral derivatization reagent to produce tartaric acid monoester derivatives of vigabatrin enantiomers that could be readily resolved by reversed phase chromatography. Derivatization conditions were statistically optimized by response surface methodology, resulting in an optimal reaction temperature of 44°C and an optimal reaction time of 30min. The derivatized diastereomers of vigabatrin and internal standard (gabapentin) were analyzed using ultra-high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry. For this analysis, an Agilent ZORBAX Rapid Resolution High Definition Eclipse Plus C18 column (100mm×2.1mm, 1.8μm) was employed for chromatographic separation using 10mM ammonium formate (pH 3.0) and methanol as mobile phase at a flow rate of 0.2mLmin -1 . The established method was validated in terms of specificity, linearity, precision, accuracy, dilution integrity, recovery, matrix effect, stability, and incurred sample reanalysis. It was linear over a range of 0.25-100.0mgL -1 for both S- and R-enantiomers (R 2 ≥0.9987 for both). Intra- and inter-day precisions and accuracies were within acceptable ranges. The method was successfully applied to determine the levels of vigabatrin enantiomers in mouse serum after administration of vigabatrin racemate. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Simultaneous detection and quantitation of organic impurities in methamphetamine by ultra-high-performance liquid chromatography-tandem mass spectrometry, a complementary technique for methamphetamine profiling.

    PubMed

    Li, Li; Brown, Jaclyn L; Toske, Steven G

    2018-04-06

    The analysis of organic impurities plays an important role in the impurity profiling of methamphetamine, which in turn provides valuable information about methamphetamine manufacturing, in particular its synthetic route, chemicals, and precursors used. Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is ideally suited for this purpose due to its excellent sensitivity, selectivity, and wide linear range in multiple reaction monitoring (MRM) mode. In this study, a dilute-and-shoot UHPLC-MS/MS method was developed for the simultaneous identification and quantitation of 23 organic manufacturing impurities in illicit methamphetamine. The developed method was validated in terms of stability, limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, and precision. More than 100 illicitly prepared methamphetamine samples were analyzed. Due to its ability to detect ephedrine/pseudoephedrine and its high sensitivity for critical target markers (eg, chloro-pseudoephedrine, N-cyclohexylamphetamine, and compounds B and P), more impurities and precursor/pre-precursors were identified and quantified versus the current procedure by gas chromatography-mass spectrometry (GC-MS). Consequently, more samples could be classified by their synthetic routes. However, the UHPLC-MS/MS method has difficulty in detecting neutral and untargeted emerging manufacturing impurities and can therefore only serve as a complement to the current method. Despite this deficiency, the quantitative information acquired by the presented UHPLC-MS/MS methodology increased the sample discrimination power, thereby enhancing the capacity of methamphetamine profiling program (MPP) to conduct sample-sample comparisons. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  11. An isotope dilution ultra high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sugars and humectants in tobacco products.

    PubMed

    Wang, Liqun; Cardenas, Roberto Bravo; Watson, Clifford

    2017-09-08

    CDC's Division of Laboratory Sciences developed and validated a new method for the simultaneous detection and measurement of 11 sugars, alditols and humectants in tobacco products. The method uses isotope dilution ultra high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and has demonstrated high sensitivity, selectivity, throughput and accuracy, with recoveries ranging from 90% to 113%, limits of detection ranging from 0.0002 to 0.0045μg/mL and coefficients of variation (CV%) ranging from 1.4 to 14%. Calibration curves for all analytes were linear with linearity R 2 values greater than 0.995. Quantification of tobacco components is necessary to characterize tobacco product components and their potential effects on consumer appeal, smoke chemistry and toxicology, and to potentially help distinguish tobacco product categories. The researchers analyzed a variety of tobacco products (e.g., cigarettes, little cigars, cigarillos) using the new method and documented differences in the abundance of selected analytes among product categories. Specifically, differences were detected in levels of selected sugars found in little cigars and cigarettes, which could help address appeal potential and have utility when product category is unknown, unclear, or miscategorized. Copyright © 2017. Published by Elsevier B.V.

  12. Determination of β-Carotene in Supplements and Raw Materials by Reversed-Phase High Pressure Liquid Chromatography

    PubMed Central

    Szpylka, John; DeVries, Jonathan W.; Bhandari, S.; Bui, M.H.; Ji, D.; Konings, E.; Lewis, R.; Maas, P.; Parish, H.; Post, B.; Schierle, J.; Sullivan, D.; Taylor, A.; Wang, J.; Ware, G.; Woollard, D.; Wu, T.

    2008-01-01

    Twelve laboratories representing 4 countries participated in an interlaboratory study conducted to determine all-trans-β-carotene and total β-carotene in dietary supplements and raw materials. Thirteen samples were sent as blind duplicates to the collaborators. Results obtained from 11 laboratories are reported. For products composed as softgels and tablets that were analyzed for total β-carotene, the reproducibility relative standard deviation (RSDR) ranged from 3.35 to 23.09% and the HorRat values ranged from 1.06 to 3.72. For these products analyzed for trans β-carotene, the reproducibility relative standard deviation (RSDR) ranged from 4.28 to 22.76% and the HorRat values ranged from 0.92 to 3.37. The RSDr and HorRat values in the analysis of a beadlet raw material were substantial and it is believed that the variability within the material itself introduced significant variation in subsampling. The method uses high pressure liquid chromatography (LC) in the reversed-phase mode with visible light absorbance for detection and quantitation. If high levels of α-carotenes are present, a second LC system is used for additional separation and quantitation of the carotene species. It is recommended that the method be adopted as an AOAC Official Method. PMID:16385976

  13. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    PubMed

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C 18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Characterization of peak capacity of microbore liquid chromatography columns using gradient kinetic plots.

    PubMed

    Hetzel, Terence; Blaesing, Christina; Jaeger, Martin; Teutenberg, Thorsten; Schmidt, Torsten C

    2017-02-17

    The performance of micro-liquid chromatography columns with an inner diameter of 0.3mm was investigated on a dedicated micro-LC system for gradient elution. Core-shell as well as fully porous particle packed columns were compared on the basis of peak capacity and gradient kinetic plot limits. The results for peak capacity showed the superior performance of columns packed with sub-2μm fully porous particles compared to 3.0μm fully porous and 2.7μm core-shell particles within a range of different gradient time to column void time ratios. For ultra-fast chromatography a maximum peak capacity of 16 can be obtained using a 30s gradient for the sub-2μm fully porous particle packed column. A maximum peak capacity of 121 can be achieved using a 5min gradient. In addition, the influence of an alternative detector cell on the basis of optical waveguide technology and contributing less to system variance was investigated showing an increased peak capacity for all applied gradient time/column void time ratios. Finally, the influence of pressure was evaluated indicating increased peak capacity for maximum performance whereas a limited benefit for ultra-fast chromatography with gradient times below 30s was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. In situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction for the determination of neurotransmitters in Parkinson's rat brain microdialysates by ultra high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    He, Yongrui; Zhao, Xian-En; Zhu, Shuyun; Wei, Na; Sun, Jing; Zhou, Yubi; Liu, Shu; Liu, Zhiqiang; Chen, Guang; Suo, Yourui; You, Jinmao

    2016-08-05

    Simultaneous monitoring of several neurotransmitters (NTs) linked to Parkinson's disease (PD) has important scientific significance for PD related pathology, pharmacology and drug screening. A new simple, fast and sensitive analytical method, based on in situ derivatization-ultrasound-assisted dispersive liquid-liquid microextraction (in situ DUADLLME) in a single step, has been proposed for the quantitative determination of catecholamines and their biosynthesis precursors and metabolites in rat brain microdialysates. The method involved the rapid injection of the mixture of low toxic bromobenzene (extractant) and acetonitrile (dispersant), which containing commercial Lissamine rhodamine B sulfonyl chloride (LRSC) as derivatization reagent, into the aqueous phase of sample and buffer, and the following in situ DUADLLME procedure. After centrifugation, 50μL of the sedimented phase (bromobenzene) was directly injected for ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection in multiple reaction monitoring (MRM) mode. This interesting combination brought the advantages of speediness, simpleness, low matrix effects and high sensitivity in an effective way. Parameters of in situ DUADLLME and UHPLC-MS/MS conditions were all optimized in detail. The optimum conditions of in situ DUADLLME were found to be 30μL of microdialysates, 150μL of acetonitrile containing LRSC, 50μL of bromobenzene and 800μL of NaHCO3-Na2CO3 buffer (pH 10.5) for 3.0min at 37°C. Under the optimized conditions, good linearity was observed with LODs (S/N>3) and LOQs (S/N>10) of LRSC derivatized-NTs in the range of 0.002-0.004 and 0.007-0.015 nmol/L, respectively. It also brought good precision (3.2-12.8%, peak area CVs%), accuracy (94.2-108.6%), recovery (94.5-105.5%) and stability (3.8-8.1%, peak area CVs%) results. Moreover, LRSC derivatization significantly improved chromatographic resolution and MS detection sensitivity of NTs when compared with the

  16. Enantioselective ultra-high and high performance liquid chromatography: a comparative study of columns based on the Whelk-O1 selector.

    PubMed

    Kotoni, Dorina; Ciogli, Alessia; D'Acquarica, Ilaria; Kocergin, Jelena; Szczerba, Ted; Ritchie, Harald; Villani, Claudio; Gasparrini, Francesco

    2012-12-21

    This paper reports on the thermodynamic and kinetic evaluation of a new ultra-high performance liquid chromatography broad-spectrum Pirkle-type chiral stationary phase (CSP) for enantioselective applications (eUHPLC). The well-known Whelk-O1 selector was covalently immobilized onto 1.7-μm high-surface-area, porous spherical silica particles to produce a totally synthetic, covalently bonded CSP that was packed into 150 mm, 100mm, 75 mm and 50mm columns, either 4.6 or 3.0mm ID. A 100 mm × 4.6 mm ID column was fully characterized from a kinetic and thermodynamic point of view, using as reference a conventional HPLC Whelk-O1 column, 250 mm×4.6mm ID, based on 5-μm porous silica particles. On the eUHPLC column, van Deemter plots generated H(min) values of 3.53 μm for 1,3-dinitrobenzene, at an interstitial mobile phase linear velocity (μ(inter)) of 5.07 mm/s, and H(min) of 4.26 and 4.17 μm for the two enantiomers of acenaphthenol, at μ(inter) of 4.85 mm/s and 4.24 mm/s, respectively. Resolution of 21 enantiomeric pairs including alcohols, epoxides, sulfoxides, phosphine oxides, benzodiazepines and 2-aryloxyproprionic esters used as herbicides, were obtained with significant advantages in terms of efficiency and analysis time. Speed gain factors were calculated for the different column geometries (150 mm, 100mm, 75 mm and 50mm, either 4.6 or 3.0mm ID), with respect to the standard HPLC column (250 mm ×4.6 mm ID), and were as high as 13, in the case of the 50-mm-long column, affording sub-minute separations of enantiomers with excellent resolution factors. In particular, trans-stilbene oxide was resolved in only 10s, while a 50 mm×3.0 mm ID column was used as a compromise between reduced mobile phase consumption (less than 1 mL per analysis) and smaller extra-column band-broadening effect. Given the relatively low viscosity in NP mode, and the excellent permeability of these eUHPLC columns, with backpressure values under 600 bar for a wide range of flow rates, the

  17. Ultra-high performance supercritical fluid chromatography of lignin-derived phenols from alkaline cupric oxide oxidation.

    PubMed

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta; Turner, Charlotta

    2016-08-01

    Traditional chromatographic methods for the analysis of lignin-derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra-high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin-derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5-2.5 μM, a limit of quantification of 2.5-5.0 μM, and a dynamic range of 5.0-2.0 mM (R(2) > 0.997). The new ultra-high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin-derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin-derived phenols in complex environmental samples. © 2016 The Authors, Journal of Separation Science Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater.

    PubMed

    Bijlsma, Lubertus; Sancho, Juan V; Pitarch, Elena; Ibáñez, Maria; Hernández, Félix

    2009-04-10

    An ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the simultaneous quantification and confirmation of 11 basic/acidic illicit drugs and relevant metabolites in surface and urban wastewater at ng/L levels. The sample pre-treatment consisted of a solid-phase extraction using Oasis MCX cartridges. Analyte deuterated compounds were used as surrogate internal standards (except for norbenzoylecgonine and norcocaine) to compensate for possible errors resulting from matrix effects and those associated to the sample preparation procedure. After SPE enrichment, the selected drugs were separated within 6min under UHPLC optimized conditions. To efficiently combine UHPLC with MS/MS, a fast-acquisition triple quadrupole mass analyzer (TQD from Waters) in positive-ion mode (ESI+) was used. The excellent selectivity and sensitivity of the TQD analyzer in selected reaction monitoring mode allowed quantification and reliable identification at the LOQ levels. Satisfactory recoveries (70-120%) and precision (RSD<20%) were obtained for most compounds in different types of water samples, spiked at two concentration levels [limit of quantification (LOQ) and 10LOQ]. Thus, surface water was spiked at 30 ng/L and 300 ng/L (amphetamine and amphetamine-like stimulants), 10 ng/L and 100 ng/L (cocaine and its metabolites), 300 ng/L and 3000 ng/L (tetrahydrocannabinol-COOH). Recovery experiments in effluent and influent wastewater were performed at spiking levels of three and fifteen times higher than the levels spiked in surface water, respectively. The validated method was applied to urban wastewater samples (influent and effluent). The acquisition of three selected reaction monitoring transitions per analyte allowed positive findings to be confirmed by accomplishment of ion ratios between the quantification transition and two additional specific confirmation transitions. In general, drug consumption increased in the weekends and

  19. (Ultra) High Pressure Homogenization for Continuous High Pressure Sterilization of Pumpable Foods – A Review

    PubMed Central

    Georget, Erika; Miller, Brittany; Callanan, Michael; Heinz, Volker; Mathys, Alexander

    2014-01-01

    Bacterial spores have a strong resistance to both chemical and physical hurdles and create a risk for the food industry, which has been tackled by applying high thermal intensity treatments to sterilize food. These strong thermal treatments lead to a reduction of the organoleptic and nutritional properties of food and alternatives are actively searched for. Innovative hurdles offer an alternative to inactivate bacterial spores. In particular, recent technological developments have enabled a new generation of high pressure homogenizer working at pressures up to 400 MPa and thus, opening new opportunities for high pressure sterilization of foods. In this short review, we summarize the work conducted on (ultra) high pressure homogenization (U)HPH to inactivate endospores in model and food systems. Specific attention is given to process parameters (pressure, inlet, and valve temperatures). This review gathers the current state of the art and underlines the potential of UHPH sterilization of pumpable foods while highlighting the needs for future work. PMID:25988118

  20. Quantification of cefazolin in serum and adipose tissue by ultra high performance liquid chromatography-Tandem mass spectrometry (UHPLC-MS/MS): application to a pilot study of obese women undergoing cesarean delivery.

    PubMed

    Lillico, Ryan; Sayre, Casey L; Sitar, Daniel S; Davies, Neal M; Baron, Cynthia M; Lakowski, Ted M

    2016-09-15

    Higher doses of cefazolin are required in obese patients for preoperative antibiotic prophylaxis, owing to its low lipophilicity. An ultra high performance liquid chromatography-tandem mass spectrometry method was developed to quantify cefazolin in serum and adipose tissue from 6 obese patients undergoing cesarean delivery, and using stable-isotope labeled cefazolin as an internal standard. The method has a 2μg/g lower limit of quantitation. The concentration in adipose tissue was 3.4±1.6μg/mL, which is less than half of the reported minimum inhibitory concentration of 8μg/mL for cefazolin. Serum cefazolin concentrations were more than 30-fold higher than in adipose tissue. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Liquid Microjunction Surface Sampling Coupled with High-Pressure Liquid Chromatography-Electrospray Ionization-Mass Spectrometry for Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    2010-01-01

    In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, twomore » isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent.« less

  2. Recent development in liquid chromatography stationary phases for separation of Traditional Chinese Medicine components.

    PubMed

    Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Wang, Jixia; Zhang, Xiuli; Wang, Chaoran; Liang, Xinmiao

    2016-10-25

    Traditional Chinese Medicine (TCM) is an ancient medical practice which has been used to prevent and cure diseases for thousands of years. TCMs are frequently multi-component systems with mainly unidentified constituents. The study of the chemical compositions of TCMs remains a hotspot of research. Different strategies have been developed to manage the significant complexity of TCMs, in an attempt to determine their constituents. Reversed-phase liquid chromatography (RPLC) is still the method of choice for the separation of TCMs, but has many problems related to limited selectivity. Recently, enormous efforts have been concentrated on the development of efficient liquid chromatography (LC) methods for TCMs, based on selective stationary phases. This can improve the resolution and peak capacity considerably. In addition, high-efficiency stationary phases have been applied in the analysis of TCMs since the invention of ultra high-performance liquid chromatography (UHPLC). This review describes the advances in LC methods in TCM research from 2010 to date, and focuses on novel stationary phases. Their potential in the separation of TCMs using relevant applications is also demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    PubMed Central

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  4. Broad screening and identification of β-agonists in feed and animal body fluid and tissues using ultra-high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry combined with spectra library search.

    PubMed

    Li, Tingting; Cao, Jingjing; Li, Zhen; Wang, Xian; He, Pingli

    2016-02-01

    Broad screening and identification of β-agonists in feed, serum, urine, muscle and liver samples was achieved in a quick and highly sensitive manner using ultra high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS) combined with a spectra library search. Solid-phase extraction technology was employed for sample purification and enrichment. After extraction and purification, the samples were analyzed using a Q-Orbitrap high-resolution mass spectrometer under full-scan and data-dependent MS/MS mode. The acquired mass spectra were compared with an in-house library (compound library and MS/MS mass spectral library) built with TraceFinder Software which contained the M/Z of the precursor ion, chemical formula, retention time, character fragment ions and the entire MS/MS spectra of 32 β-agonist standards. Screening was achieved by comparing 5 key mass spectral results and positive matches were marked. Using the developed method, the identification results from 10 spiked samples and 238 actual samples indicated that only 2% of acquired mass spectra produced false identities. The method validation results showed that the limit of detection ranged from 0.021-3.854 μg kg(-1)and 0.015-1.198 ng mL(-1) for solid and liquid samples, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Determination of pesticide residues in samples of green minor crops by gas chromatography and ultra performance liquid chromatography coupled to tandem quadrupole mass spectrometry.

    PubMed

    Walorczyk, Stanisław; Drożdżyński, Dariusz; Kierzek, Roman

    2015-01-01

    A method was developed for pesticide analysis in samples of high chlorophyll content belonging to the group of minor crops. A new type of sorbent, known as ChloroFiltr, was employed for dispersive-solid phase extraction cleanup (dispersive-SPE) to reduce the unwanted matrix background prior to concurrent analysis by gas chromatography and ultra-performance liquid chromatography coupled to tandem quadrupole mass spectrometry (GC-MS/MS and UPLC-MS/MS). Validation experiments were carried out on green, unripe plants of lupin, white mustard and sorghum. The overall recoveries at the three spiking levels of 0.01, 0.05 and 0.5 mg kg(-1) fell in the range between 68 and 120% (98% on average) and 72-104% (93% on average) with relative standard deviation (RSD) values between 2 and 19% (7% on average) and 3-16% (6% on average) by GC-MS/MS and UPLC-MS/MS technique, respectively. Because of strong enhancement or suppression matrix effects (absolute values >20%) which were exhibited by about 80% of the pesticide and matrix combinations, acceptably accurate quantification was achieved by using matrix-matched standards. Up to now, the proposed method has been successfully used to study the dissipation patterns of pesticides after application on lupin, white mustard, soya bean, sunflower and field bean in experimental plot trials conducted in Poland. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Ultrahigh pressure extraction of lignan compounds from Dysosma versipellis and purification by high-speed counter-current chromatography.

    PubMed

    Zhu, Qing; Liu, Feng; Xu, Meixia; Lin, Xiaojing; Wang, Xiao

    2012-09-15

    Ultrahigh pressure extraction (UPE) was employed to extract podophyllotoxin and 4'-demethylpodophyllotoxin from Dysosma versipellis. The effects of extraction parameters including extraction solvents, pressure, time and solid/liquid ratio were investigated using a High Hydrostatic Pressure Processor. The optimal condition for UPE of the target compounds was 80% methanol, 200 MPa of pressure, 1 min of extraction time and 1:12 (g/mL) of solid/liquid ratio. Podophyllotoxin and 4'-demethylpodophyllotoxin in the crude extract were purified by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of petroleum ether-ethyl acetate-methanol-water (10:10:8:12, v/v), and the fractions were analyzed by HPLC, ESI-MS and (1)H NMR. As a result, 73.7 mg podophyllotoxin and 16.5mg 4'-demethylpodophyllotoxin with purities over 96% were obtained from 260 mg crude sample in one-step separation. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Metabolic profiles of physalin A in rats using ultra-high performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Feng, Xinchi; Liu, Hongxia; Chai, Liwei; Ding, Liqin; Pan, Guixiang; Qiu, Feng

    2017-03-01

    Physalin A, one of the major active components isolated from the calyces of Physalis alkekengi var. franchetii is considered to be a promising natural product due to its anti-inflammatory and excellent antitumor activities. Until now, only one paper is available from our group concerning identification of two sulfonate metabolites from rat feces after physalin A treatment. All the other researches related to physalin A were focused on its extraction, separation and biological activities. In this research, a rapid and reliable ultra-high-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF-MS/MS) method was developed and employed for the comprehensive study of the metabolism of physalin A in vivo for the first time. A total of 24 proposed metabolites were identified in plasma, bile, urine and feces of rats after oral administration of physalin A. The results indicated that sulfonation, reduction and hydroxylation were the major metabolic pathways of physalin A in vivo. Furthermore, this research provides scientific and reliable support for full understanding of the metabolism of physalin A and the results could help to elucidate the safety and efficacy of physalin A, as well as other physalins. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chen, Zhi-Feng; Ying, Guang-Guo; Lai, Hua-Jie; Chen, Feng; Su, Hao-Chang; Liu, You-Sheng; Peng, Fu-Qiang; Zhao, Jian-Liang

    2012-12-01

    A sensitive and robust method using solid-phase extraction and ultrasonic extraction for preconcentration followed by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) has been developed for determination of 19 biocides: eight azole fungicides (climbazole, clotrimazole, ketoconazole, miconazole, fluconazole, itraconazole, thiabendazole, and carbendazim), two insect repellents (N,N-diethyl-3-methylbenzamide (DEET), and icaridin (also known as picaridin)), three isothiazolinone antifouling agents (1,2-benzisothiazolinone (BIT), 2-n-octyl-4-isothiazolinone (OIT), and 4,5-dichloro-2-n-octyl-isothiazolinone (DCOIT)), four paraben preservatives (methylparaben, ethylparaben, propylparaben, and butylparaben), and two disinfectants (triclosan and triclocarban) in surface water, wastewater, sediment, sludge, and soil. Recovery of the target compounds from surface water, influent, effluent, sediment, sludge, and soil was mostly in the range 70-120%, with corresponding method quantification limits ranging from 0.01 to 0.31 ng L(-1), 0.07 to 7.48 ng L(-1), 0.01 to 3.90 ng L(-1), 0.01 to 0.45 ng g(-1), 0.01 to 6.37 ng g(-1), and 0.01 to 0.73 ng g(-1), respectively. Carbendazim, climbazole, clotrimazole, methylparaben, miconazole, triclocarban, and triclosan were detected at low ng L(-1) (or ng g(-1)) levels in surface water, sediment, and sludge-amended soil. Fifteen target compounds were found in influent samples, at concentrations ranging between 0.4 (thiabendazole) and 372 ng L(-1) (methylparaben). Fifteen target compounds were found in effluent samples, at concentrations ranging between 0.4 (thiabendazole) and 114 ng L(-1) (carbendazim). Ten target compounds were found in dewatered sludge samples, at concentrations ranging between 1.1 (DEET) and 887 ng g(-1) (triclocarban).

  9. High-Pressure Open-Channel On-Chip Electroosmotic Pump for Nanoflow High Performance Liquid Chromatography

    PubMed Central

    2015-01-01

    Here, we construct an open-channel on-chip electroosmotic pump capable of generating pressures up to ∼170 bar and flow rates up to ∼500 nL/min, adequate for high performance liquid chromatographic (HPLC) separations. A great feature of this pump is that a number of its basic pump units can be connected in series to enhance its pumping power; the output pressure is directly proportional to the number of pump units connected. This additive nature is excellent and useful, and no other pumps can work in this fashion. We demonstrate the feasibility of using this pump to perform nanoflow HPLC separations; tryptic digests of bovine serum albumin (BSA), transferrin factor (TF), and human immunoglobulins (IgG) are utilized as exemplary samples. We also compare the performance of our electroosmotic (EO)-driven HPLC with Agilent 1200 HPLC; comparable efficiencies, resolutions, and peak capacities are obtained. Since the pump is based on electroosmosis, it has no moving parts. The common material and process also allow this pump to be integrated with other microfabricated functional components. Development of this high-pressure on-chip pump will have a profound impact on the advancement of lab-on-a-chip devices. PMID:24495233

  10. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  11. Optimization of ultra-performance liquid chromatography (UPLC) with fluorescence detector (FLD) method for the quantitative determination of selected neurotransmitters in rat brain.

    PubMed

    Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna

    2017-07-26

    Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  12. Ultra-performance liquid chromatography fingerprinting for quality control of Phragmitis rhizoma (Lugen) produced in Baiyangdian

    PubMed Central

    Li, Hong; Gao, Yu-Mei; Zhang, Jing; Wang, Lin; Wang, Xiao-Xin

    2013-01-01

    Objective: To establish an ultra-performance liquid chromatography (UPLC) fingerprinting method for quality control of Phragmitis rhizoma from Baiyangdian. Materials and Methods: Ultrasonic extraction with 70% methanol was performed on 10 samples of P. rhizoma collected from 10 different villages in Baiyangdian. The sample solutions were analyzed by Waters UPLC equipped with the ACQUITY UPLC BEH C18 column and photodiode array (PDA) detector, and gradient eluted with acetonitrile/water as the mobile phase. The flow rate was set to 0.1 mL/min; the column temperature was set to 25°C; and the detection wavelength was set to 285 nm. Results: The chromatograms of the 10 samples showed 27 common peaks, of which one was identified as the ferulic acid standard. The similarity indexes were all above 0.82. Hierarchical cluster analysis showed that the constituents and their quantities differed according to the diameter of the original plant, which is related to its age. Conclusion: The UPLC fingerprinting method had the advantages of being fast, accurate, and highly efficient; this indicated that it can be used for quality control of P. rhizoma produced in Baiyangdian. Also, the relation between the quality and diameter/age of the plant needs to be further investigated. PMID:24124278

  13. Ionic liquid stationary phases for gas chromatography.

    PubMed

    Poole, Colin F; Poole, Salwa K

    2011-04-01

    This article provides a summary of the development of ionic liquids as stationary phases for gas chromatography beginning with early work on packed columns that established details of the retention mechanism and established working methods to characterize selectivity differences compared with molecular stationary phases through the modern development of multi-centered cation and cross-linked ionic liquids for high-temperature applications in capillary gas chromatography. Since there are many reviews on ionic liquids dealing with all aspects of their chemical and physical properties, the emphasis in this article is placed on the role of gas chromatography played in the design of ionic liquids of low melting point, high thermal stability, high viscosity, and variable selectivity for separations. Ionic liquids provide unprecedented opportunities for extending the selectivity range and temperature-operating range of columns for gas chromatography, an area of separation science that has otherwise been almost stagnant for over a decade. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

    PubMed

    Dubbelman, Anne-Charlotte; Cuyckens, Filip; Dillen, Lieve; Gross, Gerhard; Hankemeier, Thomas; Vreeken, Rob J

    2014-12-29

    The present study investigated the practical use of modern ultra-high performance liquid chromatography (UHPLC) separation techniques for drug metabolite profiling, aiming to develop a widely applicable, high-throughput, easy-to-use chromatographic method, with a high chromatographic resolution to accommodate simultaneous qualitative and quantitative analysis of small-molecule drugs and metabolites in biological matrices. To this end, first the UHPLC system volume and variance were evaluated. Then, a mixture of 17 drugs and various metabolites (molecular mass of 151-749Da, logP of -1.04 to 6.7), was injected on six sub-2μm particle columns. Five newest generation core shell technology columns were compared and tested against one column packed with porous particles. Two aqueous (pH 2.7 and 6.8) and two organic mobile phases were evaluated, first with the same flow and temperature and subsequently at each column's individual limit of temperature and pressure. The results demonstrated that pre-column dead volume had negligible influence on the peak capacity and shape. In contrast, a decrease in post-column volume of 57% resulted in a substantial (47%) increase in median peak capacity and significantly improved peak shape. When the various combinations of stationary and mobile phases were used at the same flow rate (0.5mL/min) and temperature (45°C), limited differences were observed between the median peak capacities, with a maximum of 26%. At higher flow though (up to 0.9mL/min), a maximum difference of almost 40% in median peak capacity was found between columns. The finally selected combination of solid-core particle column and mobile phase composition was chosen for its selectivity, peak capacity, wide applicability and peak shape. The developed method was applied to rat hepatocyte samples incubated with the drug buspirone and demonstrated to provide a similar chromatographic resolution, but a 6 times higher signal-to-noise ratio than a more traditional UHPLC

  15. Rapid detection of multiple class pharmaceuticals in both municipal wastewater and sludge with ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Yuan, Xiangjuan; Qiang, Zhimin; Ben, Weiwei; Zhu, Bing; Liu, Junxin

    2014-09-01

    This work described the development, optimization and validation of an analytical method for rapid detection of multiple-class pharmaceuticals in both municipal wastewater and sludge samples based on ultrasonic solvent extraction, solid-phase extraction, and ultra high performance liquid chromatography-tandem mass spectrometry quantification. The results indicated that the developed method could effectively extract all the target pharmaceuticals (25) in a single process and analyze them within 24min. The recoveries of the target pharmaceuticals were in the range of 69%-131% for wastewater and 54%-130% for sludge at different spiked concentration levels. The method quantification limits in wastewater and sludge ranged from 0.02 to 0.73ng/L and from 0.02 to 1.00μg/kg, respectively. Subsequently, this method was validated and applied for residual pharmaceutical analysis in a wastewater treatment plant located in Beijing, China. All the target pharmaceuticals were detected in the influent samples with concentrations varying from 0.09ng/L (tiamulin) to 15.24μg/L (caffeine); meanwhile, up to 23 pharmaceuticals were detected in sludge samples with concentrations varying from 60ng/kg (sulfamethizole) to 8.55mg/kg (ofloxacin). The developed method demonstrated its selectivity, sensitivity, and reliability for detecting multiple-class pharmaceuticals in complex matrices such as municipal wastewater and sludge. Copyright © 2014. Published by Elsevier B.V.

  16. [Determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhu, Feng

    2015-01-01

    A method has been developed for the determination of di (hydrogenated tallow alkyl) dimethyl ammonium compounds (DHTDMAC) in textile auxiliaries by ultra-high performance liquid chromatography-tandem mass spectrometry. (UPLC-MS/MS). The samples were extracted and diluted with acidified methanol by 5% (v/v) formic acid under ultrasonic assistance. The separation was performed on an Eclipse Plus C18 column (50 mm x 2.1 mm, 1.8 microm) using 0.1% (v/v) formic acid solution and methanol as the mobile phases. Identification and quantification were achieved by UPLC-MS/MS with electrospray ionization (ESI) source in positive ion mode and multiple reaction monitoring (MRM) mode. The results indicated that the calibration curve of DHTDMAC showed good linear relationship between peak area and mass concentration in the range of 10-280 microg/L with the correlation coefficient (r2) of 0.9991. The limit of detection (LOD, S/N=3) and the limit of quantification (LOQ, S/N= 10) of this method were 3 mg/kg and 10 mg/kg, respectively. The average recoveries from three typical textile auxiliary matrices including dispersant, antistatic agent and fabric softener, at three spiked levels were in the range of 97.2%-108.3% with the relative standard deviations (RSDs) of 1.5%-4.6%. The method is sensitive, accurate, simple and effective for the analysis of DHTDMAC in textile auxiliaries.

  17. Characterization by high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry of the lipid fraction of Spirulina platensis pressurized ethanol extract.

    PubMed

    Herrero, Miguel; Vicente, María J; Cifuentes, Alejandro; Ibáñez, Elena

    2007-01-01

    Microalgae have been suggested as a potential source for new functional ingredients, making possible the development of new functional foods from natural origin. Among the natural ingredients, polyunsaturated fatty acids (PUFAs) have generally been identified as an interesting group of compounds with biological activity, mainly related to their anti-inflammatory properties. In this regard, the use of environmentally friendly extraction procedures (e.g. pressurized liquid extraction, PLE) to obtain such natural ingredients is also becoming necessary. In this work, an exhaustive characterization of the lipid fraction of a pressurized ethanolic extract of the microalga Spirulina platensis is carried out. To achieve this objective high-performance liquid chromatography (HPLC) coupled to quadrupole time-of-flight mass spectrometry (QTOF-MS) is employed. The use of the QTOF analyzer allows the selection and isolation of precursor ions as well as providing the high efficiency, sensitivity and mass accuracy required. By means of this powerful hyphenated technique, it was possible to identify several polar lipids in an extract of S. platensis (some of them, to our knowledge, described for the first time in this work), including four free fatty acids, four monogalactosyl monoacylglycerols, three phosphatidylglycerols and two sulfoquinovosyl diacylglycerols.

  18. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    PubMed

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    ERIC Educational Resources Information Center

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  20. Ultra-high performance liquid chromatography coupled to mass spectrometry applied to the identification of valuable phenolic compounds from Eucalyptus wood.

    PubMed

    Santos, Sónia A O; Vilela, Carla; Freire, Carmen S R; Neto, Carlos Pascoal; Silvestre, Armando J D

    2013-11-01

    Ultra-high performance liquid chromatography (UHPLC) was applied for the first time in the analysis of wood extracts. The potential of this technique coupled to ion trap mass spectrometry in the rapid and effective detection and identification of bioactive components in complex vegetal samples was demonstrated. Several dozens of compounds were detected in less than 30min of analysis time, corresponding to more than 3-fold reduction in time, when compared to conventional HPLC analysis of similar extracts. The phenolic chemical composition of Eucalyptus grandis, Eucalyptus urograndis (E. grandis×E. urophylla) and Eucalyptus maidenii wood extracts was assessed for the first time, with the identification of 51 phenolic compounds in the three wood extracts. Twenty of these compounds are reported for the first time as Eucalyptus genus components. Ellagic acid and ellagic acid-pentoside are the major components in all extracts, followed by gallic and quinic acids in E. grandis and E. urograndis and ellagic acid-pentoside isomer, isorhamnetin-hexoside and gallic acid in E. maidenii. The antioxidant scavenging activity of the extracts was evaluated, with E. grandis wood extract showing the lowest IC50 value. Moreover, the antioxidant activity of these extracts was higher than that of the commercial antioxidant BHT and of those of the corresponding bark extracts. These results, together with the phenolic content values, open good perspectives for the exploitation of these renewable resources as a source of valuable phenolic compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Liquid chromatography-electrospray ionization mass spectrometry analysis of limonoids and flavanois in seeds of grapefruits, other citrus species, and dietary supplements

    USDA-ARS?s Scientific Manuscript database

    A selective ultra-high performance liquid chromatography-didode array detector-quadrapole time of flight-mass spectrometry (UHPLC-DAD-QToF-MS) method has been developed to screen grapefruit seeds, and other citrus seed samples for limonoid aglycones, limonoid acids, limonoid glucosides and flavonoid...

  2. Ultra high performance liquid chromatography-tandem mass spectrometry vs. commercial immunoassay for determination of vancomycin plasma concentration in children. Possible implications for everyday clinical practice.

    PubMed

    Barco, Sebastiano; Castagnola, Elio; Gennai, Iulian; Barbagallo, Laura; Loy, Anna; Tripodi, Gino; Cangemi, Giuliana

    2016-10-01

    Vancomycin therapeutic drug monitoring (TDM) is necessary for effective and safetherapy. The aim of the this paper was to develop a specific and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for vancomycin quantification starting from low plasma volumes to be applied for the routine TDM in children. Samples from children receiving intravenous vancomycin were analysed using a TSQ Quantum Access MAX Triple Quadrupole system coupled with an Accela 1250 UHPLC system after a rapid protein precipitation. Gradient separation chromatography was carried out using a Hypersil GOLD aQ C18 column (50 × 2.1 mm, particle size 1.9 μm). Method performance was validated following international guidelines. UHPLC-MS/MS allowed a rapid and specific quantification of vancomycin over the range 0.1-128 μg/mL from 50 μL of plasma with high reproducibility and accuracy in the absence of matrix effect. The comparison with the commercial immunoassay performed on 138 samples demonstrated the presence of a proportional bias. The concentrations of vancomycin measured with immunoassay were found to be 4.5% (95% CI: 1.3-7.7) higher than those determined with UHPLC-MS/MS. Importantly, a clinical discordance was found in about 10% of samples analysed. This new UHPLC-MS/MS method is accurate and specific for the measurement of vancomycin starting from small (50 μL) plasma volumes. The use of UHPLC-MS/MS is recommended to prevent a misclassification of therapeutic or toxic vancomycin levels in paediatrics.

  3. Multi-constituent determination and fingerprint analysis of Scutellaria indica L. using ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Liang, Xianrui; Zhao, Cui; Su, Weike

    2015-11-01

    An ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry method integrating multi-constituent determination and fingerprint analysis has been established for quality assessment and control of Scutellaria indica L. The optimized method possesses the advantages of speediness, efficiency, and allows multi-constituents determination and fingerprint analysis in one chromatographic run within 11 min. 36 compounds were detected, and 23 of them were unequivocally identified or tentatively assigned. The established fingerprint method was applied to the analysis of ten S. indica samples from different geographic locations. The quality assessment was achieved by using principal component analysis. The proposed method is useful and reliable for the characterization of multi-constituents in a complex chemical system and the overall quality assessment of S. indica. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of atypical antipsychotics and some metabolites in in vitro samples.

    PubMed

    Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De

    2007-05-01

    The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.

  5. Ultra high performance liquid chromatography with tandem mass spectrometry screening and mutagenicity evaluation of photodegradation products of Carmoisine (E122) dye in a beverage.

    PubMed

    Yamjala, Karthik; Nainar, Meyyanathan Subramania; Ramisetti, Nageswara Rao

    2016-06-01

    The present study deals with the separation and identification of the photodegradation products formed when a commercial soft drink containing Carmoisine (E122) dye was exposed to natural sunlight. An ultra high performance liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed and validated to identify the unknown species of E122. During the study, it was observed that the dye decolourizes rapidly in beverage when compared to model standard solutions. The sunlight irradiation of beverage containing E122 resulted in four photodegradation products as identified by nontarget screening using high-resolution tandem mass spectrometry. Accurate mass measurements were used to identify the elemental composition, and to elucidate the structures of degradation products a software tool was employed. The degradation products (P1-P4) were formed from the interactions of the dye with other ingredients present in the beverage. The toxicity of the degradation products was evaluated on five bacterial strains (TA98, TA100, TA1535, TA1537, and WP2 uvrA pKM101) through an in vitro bacterial reverse mutation assay. The photodegradation products showed strong mutagenic potential in strain TA 100 (without S9) as detected by the Ames assay. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Advances in ultra-high performance liquid chromatography coupled to tandem mass spectrometry for sensitive detection of several food allergens in complex and processed foodstuffs.

    PubMed

    Planque, M; Arnould, T; Dieu, M; Delahaut, P; Renard, P; Gillard, N

    2016-09-16

    Sensitive detection of food allergens is affected by food processing and foodstuff complexity. It is therefore a challenge to detect cross-contamination in food production that could endanger an allergic customer's life. Here we used ultra-high performance liquid chromatography coupled to tandem mass spectrometry for simultaneous detection of traces of milk (casein, whey protein), egg (yolk, white), soybean, and peanut allergens in different complex and/or heat-processed foodstuffs. The method is based on a single protocol (extraction, trypsin digestion, and purification) applicable to the different tested foodstuffs: chocolate, ice cream, tomato sauce, and processed cookies. The determined limits of quantitation, expressed in total milk, egg, peanut, or soy proteins (and not soluble proteins) per kilogram of food, are: 0.5mg/kg for milk (detection of caseins), 5mg/kg for milk (detection of whey), 2.5mg/kg for peanut, 5mg/kg for soy, 3.4mg/kg for egg (detection of egg white), and 30.8mg/kg for egg (detection of egg yolk). The main advantage is the ability of the method to detect four major food allergens simultaneously in processed and complex matrices with very high sensitivity and specificity. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Montone, Carmela Maria; Piovesana, Susy; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2018-03-01

    The untargeted profiling is a promising approach for the characterization of secondary metabolites in biological matrices. Thanks to the recent rapid development of high-resolution mass spectrometry (HRMS) instrumentations, the number of applications by untargeted approaches for biological samples profiling has widely increased in the recent years. Despite the high potentialities of HRMS, however, a major issue in natural products analysis often arises in the upstream process of compounds separation. A separation technique is necessary to avoid phenomena such as signal suppression, and it is especially needed in the presence of isomeric metabolites, which are otherwise indistinguishable. Glucosinolates (GLSs), a group of secondary metabolites widely distributed among plants, resulted to be associated to the prevention of some serious diseases, such as cancer. This led to the development of several methods for the analysis of GLSs in vegetables tissues. The issue of GLSs chromatographic separation has been widely studied in the past because of the difficulty in the analysis of this highly polar and variable class of compounds. Several alternatives to reversed phase (RP) chromatography, sometimes not compatible with the coupling of liquid chromatography with mass spectrometry, have been tested for the analysis of intact GLSs. However, the availability of new stationary phases, in the last years, could allow the re-evaluation of RP chromatography for the analysis of intact GLSs. In this work, a thorough evaluation of four RP chromatographic columns for the analysis of GLSs in cauliflower (Brassica oleracea L. var. botrytis) extracts by an ultra-high performance liquid chromatographic system coupled via electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer is presented. The columns tested were the following: one column Luna Omega polar C 18 , one column Kinetex Biphenyl, one column Kinetex core-shell XB-C 18 , two columns Kinetex core-shell XB-C 18

  8. Optimizing separations in online comprehensive two-dimensional liquid chromatography.

    PubMed

    Pirok, Bob W J; Gargano, Andrea F G; Schoenmakers, Peter J

    2018-01-01

    Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations. © 2017 The Authors. Journal of Separation Science published by WILEY-VCH Verlag GmbH & Co. KGaA.

  9. A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry.

    PubMed

    Jumaah, Firas; Plaza, Merichel; Abrahamsson, Victor; Turner, Charlotta; Sandahl, Margareta

    2016-08-01

    In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for α-carotene and astaxanthin, respectively, whereas limit of quantification (LOQ) was in the range of 7.8 and 58.0 ng/mL for α-carotene and astaxanthin, respectively. Repeatability and intermediate precision of the developed UHPSFC-MS method were determined and found to be RSD < 3 % and RSD < 6 %, respectively. The method was applied in order to determine carotenoids in supercritical fluid extracts of microalgae and rosehip. Graphical Abstract Ultra-high performance supercritical fluid chromatography-a rapid separation method for the analysis of carotenoids in rosehip and microalgae samples.

  10. Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction.

    PubMed

    Deng, Fenfang; Yu, Hong; Pan, Xinhong; Hu, Guoyuan; Wang, Qiqin; Peng, Rongfei; Tan, Lei; Yang, Zhicong

    2018-02-23

    This paper demonstrated the development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of five glycopeptide antibiotics in food and biological samples. The target glycopeptide antibiotics were isolated from the samples by solvent extraction, and the extracts were cleaned with a tandem solid-phase extraction step using mixed strong cation exchange and hydrophilic/lipophilic balance cartridges. Subsequently, the analytes were eluted with different solvents, and then quantified by UHPLC-MS/MS in the positive ionization mode with multiple reaction monitoring. Under optimal conditions, good linear correlations were obtained for the five glycopeptide antibiotics in the concentration range of 1.0 μg/L to 20.0 μg/L, and with linear correlation coefficients >0.998. Employing this method, the target glycopeptide antibiotics in food and biological samples were identified with a recovery of 83.0-102%, and a low quantitation limit of 1.0 μg/kg in food and 2.0 μg/L in biological samples with low matrix effects. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. I. A thermodynamic perspective.

    PubMed

    Åsberg, Dennis; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2014-10-03

    This is the first investigation in a series that aims to enhance the scientific knowledge needed for reliable analytical method transfer between HPLC and UHPLC using the quality by design (QbD) framework. Here, we investigated the differences and similarities from a thermodynamic point of view between RP-LC separations conducted with 3.5μm (HPLC) and 1.7μm (UHPLC) C18 particles. Three different model solutes and one pharmaceutical compound were used: the uncharged cycloheptanone, the cationic benzyltriethylammonium chloride, the anionic sodium 2-naphatlene sulfonate and the pharmaceutical compound omeprazole, which was anionic at the studied pH. Adsorption data were determined for the four solutes at varying fractions of organic modifier and in gradient elution in both the HPLC and UHPLC system, respectively. From the adsorption data, the adsorption energy distribution of each compound was calculated and the adsorption isotherm model was estimated. We found that the adsorption energy distribution was similar, with only minor differences in degree of homogeneity, for HPLC and UHPLC stationary phases. The adsorption isotherm model did not change between HPLC and UHPLC, but the parameter values changed considerably especially for the ionic compounds. The dependence of the organic modifier followed the same trend in HPLC as in UHPLC. These results indicates that the adsorption mechanism of a solute is the same on HPLC and UHPLC stationary phases which simplifies design of a single analytical method applicable to both HPLC and UHPLC conditions within the QbD framework. Copyright © 2014. Published by Elsevier B.V.

  12. Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.

    PubMed

    Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning

    2017-01-01

    Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Ultra-high performance supercritical fluid chromatography hyphenated to atmospheric pressure chemical ionization high resolution mass spectrometry for the characterization of fast pyrolysis bio-oils.

    PubMed

    Crepier, Julien; Le Masle, Agnès; Charon, Nadège; Albrieux, Florian; Duchene, Pascal; Heinisch, Sabine

    2018-06-01

    Extensive characterization of complex mixtures requires the combination of powerful analytical techniques. A Supercritical Fluid Chromatography (SFC) method was previously developed, for the specific case of fast pyrolysis bio oils, as an alternative to gas chromatography (GC and GC × GC) or liquid chromatography (LC and LC × LC), both separation methods being generally used prior to mass spectrometry (MS) for the characterization of such complex matrices. In this study we investigated the potential of SFC hyphenated to high resolution mass spectrometry (SFC-HRMS) for this characterization using Negative ion Atmospheric Pressure Chemical ionization ((-)APCI) for the ionization source. The interface between SFC and (-)APCI/HRMS was optimized from a mix of model compounds with the objective of maximizing the signal to noise ratio. The main studied parameters included both make-up flow-rate and make-up composition. A methodology for the treatment of APCI/HRMS data is proposed. This latter allowed for the identification of molecular formulae. Both SFC-APCI/HRMS method and data processing method were applied to a mixture of 36 model compounds, first analyzed alone and then spiked in a bio-oil. In both cases, 19 compounds could be detected. Among them 9 could be detected in a fast pyrolysis bio-oil by targeted analysis. The whole procedure was applied to the characterization of a bio-oil using helpful representations such as mass-plots, van Krevelen diagrams and heteroatom class distributions. Finally the results were compared with those obtained with a Fourier Transform ion-cyclotron resonance mass spectrometer (FT-ICR/MS). Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Measurement of serum 3-epi-25-hydroxyvitamin D3, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in infant, paediatric and adolescent populations of Korea using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Cho, Sung E; Kim, Sollip; Kim, Young D; Lee, Hyojung; Seo, Dong H; Song, Junghan; Um, Tae H; Cho, Chong R; Kim, Nam H; Hwang, Jong H

    2017-09-01

    Background We evaluated the performance of ultra-performance liquid chromatography-tandem mass spectrometry to measure serum 3-epi-25-hydroxyvitamin D 3 , 25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 2 concentrations in 519 infant, paediatric and adolescent serum samples in Korea. Methods We used a Kinetex XB-C18 column and isocratic methanol/water (77.5/22.5, v/v) with 0.025% (v/v) high-performance liquid chromatography solvent additive flowing at 0.25 mL/min, yielding an 11 min/sample run time. A TQD triple quadrupole mass spectrometer in electrospray ionization positive ion mode with multiple reaction monitoring transition via an MSMS vitamin D kit was used to evaluate precision, carryover, ion suppression and linearity. Samples were prepared using the 4-phenyl-1,2,4-triazoline-3,5-dione derivatization method. Results Intra- and inter-run precisions were 1.23-13.28% and 1.02-10.08%, respectively. Group carryovers were -0.27% and 0.10%, respectively. There was no ion suppression. The calibration curve showed good linearity from calibrator Level 1 (11.75 nmol/L) to 6 (375 nmol/L) with R 2  > 0.9999. The 3-epi-25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 3 peaks were clearly separated in the extracted ion chromatogram. Infant serum samples 3-epi-25-hydroxyvitamin D 3 concentrations were significantly higher than paediatric and adolescent concentrations. Conclusions The ultra-performance liquid chromatography-tandem mass spectrometry assay performed acceptably, clearly separating 3-epi-25-hydroxyvitamin D 3 from 25-hydroxyvitamin D 3 . High 3-epi-25-hydroxyvitamin D 3 concentrations were observed in infant but not in paediatric and adolescent serum samples.

  15. A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC).

    PubMed

    Grosser, Katharina; van Dam, Nicole M

    2017-03-15

    Glucosinolates are a well-studied and highly diverse class of natural plant compounds. They play important roles in plant resistance, rapeseed oil quality, food flavoring, and human health. The biological activity of glucosinolates is released upon tissue damage, when they are mixed with the enzyme myrosinase. This results in the formation of pungent and toxic breakdown products, such as isothiocyanates and nitriles. Currently, more than 130 structurally different glucosinolates have been identified. The chemical structure of the glucosinolate is an important determinant of the product that is formed, which in turn determines its biological activity. The latter may range from detrimental (e.g., progoitrin) to beneficial (e.g., glucoraphanin). Each glucosinolate-containing plant species has its own specific glucosinolate profile. For this reason, it is important to correctly identify and reliably quantify the different glucosinolates present in brassicaceous leaf, seed, and root crops or, for ecological studies, in their wild relatives. Here, we present a well-validated, targeted, and robust method to analyze glucosinolate profiles in a wide range of plant species and plant organs. Intact glucosinolates are extracted from ground plant materials with a methanol-water mixture at high temperatures to disable myrosinase activity. Thereafter, the resulting extract is brought onto an ion-exchange column for purification. After sulfatase treatment, the desulfoglucosinolates are eluted with water and the eluate is freeze-dried. The residue is taken up in an exact volume of water, which is analyzed by high-pressure liquid chromatography (HPLC) with a photodiode array (PDA) or ultraviolet (UV) detector. Detection and quantification are achieved by conducting comparisons of the retention times and UV spectra of commercial reference standards. The concentrations are calculated based on a sinigrin reference curve and well-established response factors. The advantages and

  16. A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC)

    PubMed Central

    Grosser, Katharina; van Dam, Nicole M.

    2017-01-01

    Glucosinolates are a well-studied and highly diverse class of natural plant compounds. They play important roles in plant resistance, rapeseed oil quality, food flavoring, and human health. The biological activity of glucosinolates is released upon tissue damage, when they are mixed with the enzyme myrosinase. This results in the formation of pungent and toxic breakdown products, such as isothiocyanates and nitriles. Currently, more than 130 structurally different glucosinolates have been identified. The chemical structure of the glucosinolate is an important determinant of the product that is formed, which in turn determines its biological activity. The latter may range from detrimental (e.g., progoitrin) to beneficial (e.g., glucoraphanin). Each glucosinolate-containing plant species has its own specific glucosinolate profile. For this reason, it is important to correctly identify and reliably quantify the different glucosinolates present in brassicaceous leaf, seed, and root crops or, for ecological studies, in their wild relatives. Here, we present a well-validated, targeted, and robust method to analyze glucosinolate profiles in a wide range of plant species and plant organs. Intact glucosinolates are extracted from ground plant materials with a methanol-water mixture at high temperatures to disable myrosinase activity. Thereafter, the resulting extract is brought onto an ion-exchange column for purification. After sulfatase treatment, the desulfoglucosinolates are eluted with water and the eluate is freeze-dried. The residue is taken up in an exact volume of water, which is analyzed by high-pressure liquid chromatography (HPLC) with a photodiode array (PDA) or ultraviolet (UV) detector. Detection and quantification are achieved by conducting comparisons of the retention times and UV spectra of commercial reference standards. The concentrations are calculated based on a sinigrin reference curve and well-established response factors. The advantages and

  17. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  18. Profiling and identification of chlorogenic acid metabolites in rats by ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometer.

    PubMed

    Wang, Fei; Shang, Zhanpeng; Xu, Lulu; Wang, Zhibin; Zhao, Wenjing; Mei, XiaoDan; Lu, Jianqiu; Zhang, Jia Yu

    2018-06-01

    1. Chlorogenic acids (CGAs), one kind of major bioactive constituents isolated from Flos Lonicera Japonica, possess many biological activities, such as antibacterial, antioxidant and antiviral activities. In this study, we established an efficient strategy using ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry (UHPLC-LTQ-Orbitrap MS) to profile the in vivo metabolic fate of CGAs in rat urine and plasma. 2. The extract from Flos Lonicera Japonica was orally administrated to Sprague-Dawley (SD) rats at a dose of 1000 mg/kg body weight. Then, a combination of various post-acquisition data mining methods, including high-resolution extracted ion chromatogram (HREIC) and multiple mass defect filters (MMDFs) and diagnostic product ions (DPIs), were adopted to characterize the known and unknown CGA metabolites in SD rats. 3. As a result, a total of 68 CGA metabolites were unambiguously or tentatively screened and characterized. These metabolites, including 18 prototype compounds and 50 metabolites, were deduced to be yielded via methylation, hydrogenation, demethylation, dehydration, sulfate conjugation, glucuronide conjugation, glycosylation conjugation and their composite reactions, which mainly occurred to caffeoylquinic acids, dicaffeoylquinic acids, p-coumaroylquinic acids and feruloylquinic acids. 4. In conclusion, this study profiled CGA metabolites, which are useful in understanding the in vivo metabolic fate, effective forms, and pharmacological and toxic actions of CGAs.

  19. Ultra-high pressure water jetting for coating removal and surface preparation

    NASA Technical Reports Server (NTRS)

    Johnson, Spencer T.

    1995-01-01

    This paper shall examine the basics of water technology with particular attention paid to systems currently in use and some select new applications. By providing an overview of commercially available water jet systems in the context of recent case histories, potential users may evaluate the process for future applications. With the on going introduction of regulations prohibiting the use of chemical paint strippers, manual scrapping and dry abrasive media blasting, the need for an environmentally compliant coating removal process has been mandated. Water jet cleaning has been a traditional part of many industrial processed for year, although it has only been in the last few years that reliable pumping equipment capable of ultra-high pressure operation have become available. With the advent of water jet pumping equipment capable of sustaining pressures in excess of 36,000 psi. there has been shift away from lower pressure, high water volume systems. One of the major factors in driving industry to seek higher pressures is the ability to offer higher productivity rates while lowering the quantity of water used and subsequently reprocessed. Among benefits of the trend toward higher pressure/lower volume systems is the corresponding reduction in water jet reaction forces making hand held water jetting practical and safe. Other unique applications made possible by these new generation pumping systems include the use of alternative fluids including liquid ammonia for specialized and hazardous material removal applications. A review of the equipment used and the required modifications will be presented along with the conclusions reached reached during this test program.

  20. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  1. Simultaneous determination of 11 designated hallucinogenic phenethylamines by ultra-fast liquid chromatography with fluorescence detection.

    PubMed

    Min, Jun Zhe; Shimizu, Yoshiha; Toyo'oka, Toshimasa; Inagaki, Shinsuke; Kikura-Hanajiri, Ruri; Goda, Yukihiro

    2008-10-01

    To avoid the spreading of illegal drugs, a designated drug regulation system was introduced along with revision of the Pharmaceutical Affairs Law in Japan in 2006, and 32 substances including phenethylamine-type drugs were listed in April 2007. In this study, a new simultaneous determination method, based on ultra-fast liquid chromatography coupled with fluorescence detection (UFLC-FL), was developed for the 11 designated phenethylamine drugs. The phenethylamines were labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 2h in 0.1M borax (pH 9.3). The resulting 11 fluorophores were completely separated by reversed-phase chromatography using an ACQUITY UPLC BEH C(18) column (2.1 mm x 100 mm 1.7 microm) and fluorometrically detected at 550 nm (excitation at 450 nm). The calibration curves obtained from the peak areas versus the injection amounts of the phenethylamines showed a good linearity. The limits of detection (signal-to-noise ratio of 3: S/N=3) on the chromatogram were in the range from 10 fmol (PMMA) to 2.5pmol (MMDA-2). Good accuracy (%) and precision (CV) by intra-day assay and inter-day assay were also obtained using the present procedure. The method was applied to the qualitative and quantitative analyses of phenethylamine in real products obtained from the Japanese market. As the results, BDB (0.24 mg/mg), MMDA-2 (0.98 mg/mL) and 2C-I (0.016 mg/mg) were identified from the different products (powder, liquid and mushroom like). Because the procedure is simple, selective and sensitive, the present method seems to be useful for the qualitative and quantitative analyses of the designated phenethylamines in various samples including biological specimens.

  2. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    PubMed

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    PubMed

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Fast, rugged and sensitive ultra high pressure liquid chromatography tandem mass spectrometry method for analysis of cyanotoxins in raw water and drinking water--First findings of anatoxins, cylindrospermopsins and microcystin variants in Swedish source waters and infiltration ponds.

    PubMed

    Pekar, Heidi; Westerberg, Erik; Bruno, Oscar; Lääne, Ants; Persson, Kenneth M; Sundström, L Fredrik; Thim, Anna-Maria

    2016-01-15

    Freshwater blooms of cyanobacteria (blue-green algae) in source waters are generally composed of several different strains with the capability to produce a variety of toxins. The major exposure routes for humans are direct contact with recreational waters and ingestion of drinking water not efficiently treated. The ultra high pressure liquid chromatography tandem mass spectrometry based analytical method presented here allows simultaneous analysis of 22 cyanotoxins from different toxin groups, including anatoxins, cylindrospermopsins, nodularin and microcystins in raw water and drinking water. The use of reference standards enables correct identification of toxins as well as precision of the quantification and due to matrix effects, recovery correction is required. The multi-toxin group method presented here, does not compromise sensitivity, despite the large number of analytes. The limit of quantification was set to 0.1 μg/L for 75% of the cyanotoxins in drinking water and 0.5 μg/L for all cyanotoxins in raw water, which is compliant with the WHO guidance value for microcystin-LR. The matrix effects experienced during analysis were reasonable for most analytes, considering the large volume injected into the mass spectrometer. The time of analysis, including lysing of cell bound toxins, is less than three hours. Furthermore, the method was tested in Swedish source waters and infiltration ponds resulting in evidence of presence of anatoxin, homo-anatoxin, cylindrospermopsin and several variants of microcystins for the first time in Sweden, proving its usefulness. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  5. In vivo study on the neurotransmitters and their metabolites change in depressive disorder rat plasma by ultra high performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Zhao, Longshan; Zheng, Shuning; Su, Guangyue; Lu, Xiumei; Yang, Jingyu; Xiong, Zhili; Wu, Chunfu

    2015-04-15

    A sensitive and versatile, ultra-high performance, liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method coupled to pre-column derivatization for the simultaneous determination of 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA), dopamine (DA), norepinephrine (NE), homovanillic acid (HVA), γ-aminobutyric acid (GABA) and glutamic acid (Glu) was developed and validated in rat plasma. The analytes were dansylated under strong alkaline conditions after protein precipitation extraction, which were analyzed on a BEH C18 column using a gradient elution. The lower limit of quantification (LLOQ) values for 5-HT, 5-HIAA, DA, NE, HVA, GABA and Glu were 1.00, 1.00, 0.991, 0.992, 1.02, 1000, and 5030 pmol/mL, respectively. Good linearity was obtained (r > 0.99) and the intra- and inter-day precisions of the method (relative standard deviation, RSD%) were lower than 12%. The method was novel, sensitive and specific which can provide an alternative method for the quantification of neurotransmitters and their metabolites in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry for highly rapid and sensitive analysis of underivatized amino acids in functional foods.

    PubMed

    Zhou, Guisheng; Pang, Hanqing; Tang, Yuping; Yao, Xin; Mo, Xuan; Zhu, Shaoqing; Guo, Sheng; Qian, Dawei; Qian, Yefei; Su, Shulan; Zhang, Li; Jin, Chun; Qin, Yong; Duan, Jin-ao

    2013-05-01

    This work presented a new analytical methodology based on hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry in multiple-reaction monitoring mode for analysis of 24 underivatized free amino acids (FAAs) in functional foods. The proposed method was first reported and validated by assessing the matrix effects, linearity, limit of detections and limit of quantifications, precision, repeatability, stability and recovery of all target compounds, and it was used to determine the nutritional substances of FAAs in ginkgo seeds and further elucidate the nutritional value of this functional food. The result showed that ginkgo seed turned out to be a good source of FAAs with high levels of several essential FAAs and to have a good nutritional value. Furthermore, the principal component analysis was performed to classify the ginkgo seed samples on the basis of 24 FAAs. As a result, the samples could be mainly clustered into three groups, which were similar to areas classification. Overall, the presented method would be useful for the investigation of amino acids in edible plants and agricultural products.

  7. Study of tamoxifen urinary metabolites in rat by ultra-high-performance liquid chromatography time-of-flight mass spectrometry.

    PubMed

    Domínguez-Romero, Juan C; García-Reyes, Juan F; Beneito-Cambra, Miriam; Martínez-Romero, Rubén; Martinez-Lara, Esther; Del Moral-Leal, María L; Molina-Díaz, Antonio

    2015-08-01

    Tamoxifen (TMX) is a nonsteroidal estrogen antagonist drug used for the treatment of breast cancer. It is also included in the list of banned substances of the World Anti Doping Agency (WADA) prohibited in and out of competition. In this work, the excretion of urinary metabolites of TMX after a single therapeutic dose administration in rats has been studied using ultra-high-performance liquid chromatography electrospray time-of-flight mass spectrometry (UHPLC-TOFMS). A systematic strategy based on the search of typical biotransformations that a xenobiotic can undergo in living organisms, based on their corresponding molecular formula modification and accurate mass shifts, was applied for the identification of TMX metabolites. Prior to UHPLC-TOFMS analyses, a solid-phase extraction step with polymeric cartridges was applied to urine samples. Up to 38 TMX metabolites were detected. Additional collision induced dissociation (CID) MS/MS fragmentation was performed using UHPLC-QTOFMS. Compared with recent previous studies in human urine and plasma, new metabolites have been reported for the first time in urine. Metabolites identified in rat urine include the oxygen addition, owing to different possibilities for the hydroxylation of the rings in different positions (m/z 388.2271), the incorporation of two oxygen atoms (m/z 404.2220) (including dihydroxylated derivatives or alternatives such as epoxidation plus hydroxylation or N-oxidation and hydroxylation), epoxide formation or hydroxylation and dehydrogenation [m/z 386.2114 (+O -H2 )], hydroxylation of the ring accompanied by N-desmethylation (m/z 374.2115), combined hydroxylation and methoxylation (m/z 418.2377), desaturated TMX derivate (m/z 370.2165) and its N-desmethylated derivate (m/z 356.2009), the two latter modifications not previously being reported in urine. These findings confirm the usefulness of the proposed approach based on UHPLC-TOFMS. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Characterization of the multiple components of Acanthopanax Senticosus stem by ultra high performance liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Sun, Hui; Liu, Jianhua; Zhang, Aihua; Zhang, Ying; Meng, Xiangcai; Han, Ying; Zhang, Yingzhi; Wang, Xijun

    2016-02-01

    Acanthopanax Senticosus Harms. has been used widely in traditional Chinese medicine for the treatment of chronic bronchitis, neurasthenia, hypertension and ischemic heart disease. However, the in vivo constituents of the stem of Acanthopanax Senticosus remain unknown. In this paper, ultra high performance liquid chromatography with electrospray ionization quadrupole time-of-flight mass spectrometry and the MarkerLynx(TM) software combined with multiple data processing approach were used to study the constituents in vitro and in vivo. The aqueous extract from the Acanthopanax Senticosus stem and the compositions in rat serum after intragastric administration were completely analyzed. Consequently, 115 compounds in the aqueous extract from Acanthopanax Senticosus stem and 41 compounds absorbed into blood were characterized. Of the 115 compounds in vitro, 54 were reported for first time, including sinapyl alcohol, sinapyl alcohol diglucoside, and 1-O-sinapoyl-β-D-glucose. In the 41 compounds in vivo, 7 were prototype components and 34 were metabolites which were from 21 components of aqueous extract from Acanthopanax Senticosus stem, and the metabolic pathways of the metabolites were elucidated for first time. The results narrowed the range of screening the active components and provided a basis for the study of action mechanism and pharmacology. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. [Determination of 11 mycotoxins in baked foods and raw materials by ultra performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry].

    PubMed

    Li, Rong; He, Chunmei; Yang, Luqi; Wang, Yong; Zhang, Pengjie; Gao, Yongqing

    2017-08-08

    A method for the determination of 11 mycotoxins in baked foods and raw materials by ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high-resolution mass spectrometry (UPLC-HRMS) is reported in this paper. The samples were extracted with 20 mL 90% (v/v) acetonitrile aqueous solution containing 1% (v/v) formic acid, and the extracts were salted out by 2.0 g MgSO 4 and 0.5 g NaCl, cleaned up by 300 mg C18. The analytes were carried out on a CORTECS C18 column (100 mm×2.1 mm, 1.6 μ m) by gradient elution with 2 mmol/L ammonium acetate with 0.1% (v/v) formic acid aqueous solution and 2 mmol/L ammonium acetate methanol with 0.1% (v/v) formic acid. The results showed that the 11 mycotoxins had good linear relationships in their respective mass concentration ranges. The correlation coefficients were not less than 0.9960 and the limits of quantitation (LOQs) were from 0.15 to 20.00 μ g/kg. The recoveries of the 11 mycotoxins in bread ranged from 64.38% to 122.61% with the relative standard deviations (RSDs) from 1.52% to 12.99% at three spiked levels ( n =6). The method is demonstrated to be simple, fast, highly sensitive, reliable and it is effective to detect common mycotoxins in baked foods and raw materials.

  10. Comprehensive chemical comparison of fuel composition and aerosol particles emitted from a ship diesel engine by gas chromatography atmospheric pressure chemical ionisation ultra-high resolution mass spectrometry with improved data processing routines.

    PubMed

    Rüger, Christopher P; Schwemer, Theo; Sklorz, Martin; O'Connor, Peter B; Barrow, Mark P; Zimmermann, Ralf

    2017-02-01

    The analysis of petrochemical materials and particulate matter originating from combustion sources remains a challenging task for instrumental analytical techniques. A detailed chemical characterisation is essential for addressing health and environmental effects. Sophisticated instrumentation, such as mass spectrometry coupled with chromatographic separation, is capable of a comprehensive characterisation, but needs advanced data processing methods. In this study, we present an improved data processing routine for the mass chromatogram obtained from gas chromatography hyphenated to atmospheric pressure chemical ionisation and ultra high resolution mass spectrometry. The focus of the investigation was the primary combustion aerosol samples, i.e. particulate matter extracts, as well as the corresponding fossil fuels fed to the engine. We demonstrate that utilisation of the entire transient and chromatographic information results in advantages including minimisation of ionisation artefacts and a reliable peak assignment. A comprehensive comparison of the aerosol and the feed fuel was performed by applying intensity weighted average values, compound class distribution and principle component analysis. Certain differences between the aerosol generated with the two feed fuels, diesel fuel and heavy fuel oil, as well as between the aerosol and the feed were revealed. For the aerosol from heavy fuel oil, oxidised species from the CHN and CHS class precursors of the feed were predominant, whereas the CHO x class is predominant in the combustion aerosol from light fuel oil. Furthermore, the complexity of the aerosol increases significantly compared to the feed and incorporating a higher chemical space. Coupling of atmospheric pressure chemical ionisation to gas chromatography was found to be a useful additional approach for characterisation of a combustion aerosol, especially with an automated utilisation of the information from the ultra-high resolution mass spectrometer

  11. Quality control of modified xiaoyao san through the determination of 22 active components by ultra-performance liquid chromatography.

    PubMed

    Qin, Feng; Huang, Jun; Qiu, Xinjian; Hu, Sihang; Huang, Xi

    2011-01-01

    A simple, sensitive, and reliable ultra-performance liquid chromatography (UPLC) method has been developed for simultaneous determination of 22 major constituents in modified xiaoyao san (MXS), a multiherbal formula. The chromatographic separation was performed on an ACQUITY UPLC BEH C18 column (150 x 2.1 mm, 1.7 microm, particle size), with an aqueous 0.5% acetic acid and acetonitrile mobile phase gradient. The method was validated for linearity (r2 >0.9937), intraday and interday precision (RSD <8.51%), recovery (91.18-107.73%), LOD (0.02-4.17 ng/mL), and LOQ (0.05-12.50 ng/mL). The established method was successfully applied to quantify the 22 marker compounds in MXS, which provided a useful basis of overall evaluation of the quality of MXS.

  12. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    PubMed

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc ® inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Inactivation of Bacillus spores inoculated in milk by Ultra High Pressure Homogenization.

    PubMed

    Amador Espejo, Genaro Gustavo; Hernández-Herrero, M M; Juan, B; Trujillo, A J

    2014-12-01

    Ultra High-Pressure Homogenization treatments at 300 MPa with inlet temperatures (Ti) of 55, 65, 75 and 85 °C were applied to commercial Ultra High Temperature treated whole milk inoculated with Bacillus cereus, Bacillus licheniformis, Bacillus sporothermodurans, Bacillus coagulans, Geobacillus stearothermophilus and Bacillus subtilis spores in order to evaluate the inactivation level achieved. Ultra High-Pressure Homogenization conditions at 300 MPa with Ti = 75 and 85 °C were capable of a spore inactivation of ∼5 log CFU/mL. Furthermore, under these processing conditions, commercial sterility (evaluated as the complete inactivation of the inoculated spores) was obtained in milk, with the exception of G. stearothermophilus and B. subtilis treated at 300 MPa with Ti = 75 °C. The results showed that G. stearothermophilus and B. subtilis have higher resistance to the Ultra High-Pressure Homogenization treatments applied than the other microorganisms inoculated and that a treatment performed at 300 MPa with Ti = 85 °C was necessary to completely inactivate these microorganisms at the spore level inoculated (∼1 × 10(6) CFU/mL). Besides, a change in the resistance of B. licheniformis, B. sporothermodurans, G. stearothermophilus and B. subtilis spores was observed as the inactivation obtained increased remarkably in treatments performed with Ti between 65 and 75 °C. This study provides important evidence of the suitability of UHPH technology for the inactivation of spores in high numbers, leading to the possibility of obtaining commercially sterile milk. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Ultrasonic level sensors for liquids under high pressure

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Mazel, D. S.; Hodges, D. Y.

    1986-01-01

    An ultrasonic level sensor of novel design continuously measures the level of a liquid subjected to a high pressure (up to about 40 MPa), as is sometimes required for the effective transfer of the liquid. The sensor operates as a composite resonator fabricated from a standard high-pressure plug. A flat-bottom hole is machined into the plug along its center line. An ultrasonic transducer is bonded rigidly to the interior surface of the bottom wall, while the exterior surface is in contact with the liquid. Although the bottom wall is designed to satisfy the pressure code, it is still sufficiently thin to permit ready excitation of the axisymmetric plate modes of vibration. The liquid level is measured by a conventional pulse-echo technique. A prototype sensor was tested successfully in a 2300-l water vessel at pressures up to about 37 MPa. A spectral analysis of the transmitted pulse reveals that the flexural, extensional, thickness-shear, and radial plate modes are excited into vibration, but none of these appears to be significantly affected by the pressurization of the liquid.

  15. Highly sensitive screening method for nitroaromatic, nitramine and nitrate ester explosives by high performance liquid chromatography-atmospheric pressure ionization-mass spectrometry (HPLC-API-MS) in forensic applications.

    PubMed

    Xu, Xiaoma; van de Craats, Anick M; de Bruyn, Peter C A M

    2004-11-01

    A highly sensitive screening method based on high performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC-API-MS) has been developed for the analysis of 21 nitroaromatic, nitramine and nitrate ester explosives, which include the explosives most commonly encountered in forensic science. Two atmospheric pressure ionization (API) methods, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), and various experimental conditions have been applied to allow for the detection of all 21 explosive compounds. The limit of detection (LOD) in the full-scan mode has been found to be 0.012-1.2 ng on column for the screening of most explosives investigated. For nitrobenzene, an LOD of 10 ng was found with the APCI method in the negative mode. Although the detection of nitrobenzene, 2-, 3-, and 4-nitrotoluene is hindered by the difficult ionization of these compounds, we have found that by forming an adduct with glycine, LOD values in the range of 3-16 ng on column can be achieved. Compared with previous screening methods with thermospray ionization, the API method has distinct advantages, including simplicity and stability of the method applied, an extended screening range and a low detection limit for the explosives studied.

  16. Ultra high performance liquid chromatography tandem mass spectrometry for rapid analysis of trace organic contaminants in water

    PubMed Central

    2013-01-01

    Background The widespread utilization of organic compounds in modern society and their dispersion through wastewater have resulted in extensive contamination of source and drinking waters. The vast majority of these compounds are not regulated in wastewater outfalls or in drinking water while trace amounts of certain compounds can impact aquatic wildlife. Hence it is prudent to monitor these contaminants in water sources until sufficient toxicological data relevant to humans becomes available. A method was developed for the analysis of 36 trace organic contaminants (TOrCs) including pharmaceuticals, pesticides, steroid hormones (androgens, progestins, and glucocorticoids), personal care products and polyfluorinated compounds (PFCs) using a single solid phase extraction (SPE) technique with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was applied to a variety of water matrices to demonstrate method performance and reliability. Results UHPLC-MS/MS in both positive and negative electrospray ionization (ESI) modes was employed to achieve optimum sensitivity while reducing sample analysis time (<20 min) compared with previously published methods. The detection limits for most compounds was lower than 1.0 picogram on the column while reporting limits in water ranged from 0.1 to 15 ng/L based on the extraction of a 1 L sample and concentration to 1 mL. Recoveries in ultrapure water for most compounds were between 90-110%, while recoveries in surface water and wastewater were in the range of 39-121% and 38-141% respectively. The analytical method was successfully applied to analyze samples across several different water matrices including wastewater, groundwater, surface water and drinking water at different stages of the treatment. Among several compounds detected in wastewater, sucralose and TCPP showed the highest concentrations. Conclusion The proposed method is sensitive, rapid and robust; hence it can

  17. Simultaneous Determination of Underivatized Vitamin B1 and B6 in Whole Blood by Reversed Phase Ultra High Performance Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Puts, Johan; de Groot, Monique; Haex, Martin; Jakobs, Bernadette

    2015-01-01

    Background Vitamin B1 (thiamine-diphosphate) and B6 (pyridoxal-5’phosphate) are micronutrients. Analysis of these micronutrients is important to diagnose potential deficiency which often occurs in elderly people due to malnutrition, in severe alcoholism and in gastrointestinal compromise due to bypass surgery or disease. Existing High Performance Liquid Chromatography (HPLC) based methods include the need for derivatization and long analysis time. We developed an Ultra High Performance Liquid Chromatography Tandem Mass spectrometry (UHPLC-MS/MS) assay with internal standards for simultaneous measurement of underivatized thiamine-diphosphate and pyridoxal-5’phosphate without use of ion pairing reagent. Methods Whole blood, deproteinized with perchloric acid, containing deuterium labelled internal standards thiamine-diphosphate(thiazole-methyl-D3) and pyridoxal-5’phosphate(methyl-D3), was analyzed by UHPLC-MS/MS. The method was validated for imprecision, linearity, recovery and limit of quantification. Alternate (quantitative) method comparisons of the new versus currently used routine HPLC methods were established with Deming regression. Results Thiamine-diphosphate and pyridoxal-5’phosphate were measured within 2.5 minutes instrumental run time. Limits of detection were 2.8 nmol/L and 7.8 nmol/L for thiamine-diphosphate and pyridoxal-5’phosphate respectively. Limit of quantification was 9.4 nmol/L for thiamine-diphosphate and 25.9 nmol/L for pyridoxal-5’phosphate. The total imprecision ranged from 3.5–7.7% for thiamine-diphosphate (44–157 nmol/L) and 6.0–10.4% for pyridoxal-5’phosphate (30–130 nmol/L). Extraction recoveries were 101–102% ± 2.5% (thiamine-diphosphate) and 98–100% ± 5% (pyridoxal-5’phosphate). Deming regression yielded slopes of 0.926 and 0.990 in patient samples (n = 282) and national proficiency testing samples (n = 12) respectively, intercepts of +3.5 and +3 for thiamine-diphosphate (n = 282 and n = 12) and slopes of

  18. A rapid ultrasound-assisted dispersive liquid-liquid microextraction followed by ultra-performance liquid chromatography for the simultaneous determination of seven benzodiazepines in human plasma samples.

    PubMed

    Fernández, Purificación; González, Cristina; Pena, M Teresa; Carro, Antonia M; Lorenzo, Rosa A

    2013-03-12

    A simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) method has been developed for the determination of seven benzodiazepines (alprazolam, bromazepam, clonazepam, diazepam, lorazepam, lormetazepam and tetrazepam) in human plasma samples. Chloroform and methanol were used as extractant and disperser solvents, respectively. The influence of several variables (e.g., type and volume of dispersant and extraction solvents, pH, ultrasonic time and ionic strength) was carefully evaluated and optimized, using an asymmetric screening design 3(2)4(2)//16. Analysis of extracts was performed by ultra-performance liquid chromatography coupled with photodiode array detection (UPLC-PDA). Under the optimum conditions, two reversed-phases, Shield RP18 and C18 columns were successfully tested, obtaining good linearity in a range of 0.01-5μgmL(-1), with correlation coefficients r>0.996. Quantification limits ranged between 4.3-13.2ngmL(-1) and 4.0-14.8ngmL(-1), were obtained for C18 and Shield RP18 columns, respectively. The optimized method exhibited a good precision level, with relative standard deviation values lower than 8%. The recoveries studied at two spiked levels, ranged from 71 to 102% for all considered compounds. The proposed method was successfully applied to the analysis of seven benzodiazepines in real human plasma samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Highly sensitive reversed-phase high-performance liquid chromatography assay for the detection of Tamm-Horsfall protein in human urine.

    PubMed

    Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo

    2016-01-01

    Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.

  20. Optimizing separations in online comprehensive two‐dimensional liquid chromatography

    PubMed Central

    Gargano, Andrea F.G.; Schoenmakers, Peter J.

    2017-01-01

    Abstract Online comprehensive two‐dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two‐dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two‐dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high‐molecular‐weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one‐dimensional liquid chromatography, two‐dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two‐dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two‐dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two‐dimensional liquid chromatography separations. PMID:29027363

  1. Application of Ultra-performance Liquid Chromatography with Time-of-Flight Mass Spectrometry for the Rapid Analysis of Constituents and Metabolites from the Extracts of Acanthopanax senticosus Harms Leaf

    PubMed Central

    Zhang, Yingzhi; Zhang, Aihua; Zhang, Ying; Sun, Hui; Meng, Xiangcai; Yan, Guangli; Wang, Xijun

    2016-01-01

    Acanthopanax senticosus (Rupr and Maxim) Harms (AS), a member of Araliaceae family, is a typical folk medicinal herb, which is widely distributed in the Northeastern part of China. Due to lack of this resource caused by the extensive use of its root, this work studied the chemical constituents of leaves of this plant with the purpose of looking for an alternative resource. In this work, a fast and optimized ultra-performance liquid chromatography method with quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) has been developed for the analysis of constituents in leaves extracts. A total of 131 compounds were identified or tentatively characterized including triterpenoid saponins, phenols, flavonoids, lignans, coumarins, polysaccharides, and other compounds based on their fragmentation behaviors. Besides, a total of 21 metabolites were identified in serum in rats after oral administration, among which 12 prototypes and 9 metabolites through the metabolic pathways of reduction, methylation, sulfate conjugation, sulfoxide to thioether and deglycosylation. The coupling of UPLC-QTOF-MS led to the in-depth characterization of the leaves extracts of AS both in vitro and in vivo on the basis of retention time, mass accuracy, and tandem MS/MS spectra. It concluded that this analytical tool was very valuable in the study of complex compounds in medicinal herb. HIGHLIGHT OF PAPER A fast UPLC-QTOF-MS has been developed for analysis of constituents in leaves extractsA total of 131 compounds were identified in leaves extractsA total of 21 metabolites including 12 prototypes and 9 metabolites were identified in vivo. SUMMARY Constituent’s analysis of Acanthopanax senticosus Harms leaf by ultra-performance liquid chromatography method with quadrupole time-of-flight mass spectrometry. Abbreviations used: AS: Acanthopanax senticosus (Rupr and Maxim) Harms, TCHM: Traditional Chinese herbal medicine, UPLC-QTOF-MS: Ultra-performance liquid chromatography method with time

  2. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    ERIC Educational Resources Information Center

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  4. A novel high-throughput method for supported liquid extraction of retinol and alpha-tocopherol from human serum and simultaneous quantitation by liquid chromatography tandem mass spectrometry.

    PubMed

    Hinchliffe, Edward; Rudge, James; Reed, Paul

    2016-07-01

    Measurement of vitamin A (retinol) and E (alpha-tocopherol) in UK clinical laboratories is currently performed exclusively by high-performance liquid chromatography with ultraviolet detection. We investigated whether retinol and alpha-tocopherol could be measured simultaneously by liquid chromatography tandem mass spectrometry. Serum samples (100 μL) were extracted using Isolute + Supported Liquid Extraction plates. Chromatography was performed on a Phenomenex Kinetex Biphenyl 2.6 μm, 50 × 2.1 mm column, and liquid chromatography tandem mass spectrometry on a Waters Acquity TQD. Injection-to-injection time was 4.3 min. The assay was validated according to published guidelines. Patient samples were used to compare liquid chromatography tandem mass spectrometry and high-performance liquid chromatography with ultraviolet detection methods. For retinol and alpha-tocopherol, respectively, the assay was linear up to 6.0 and 80.0 μmol/L, and lower limit of quantification was 0.07 and 0.26 μmol/L. Intra and interassay imprecision were within desirable analytical specifications. Analysis of quality control material aligned to NIST SRM 968e, and relative spiked recovery from human serum, both yielded results within 15% of target values. Method comparison with high-performance liquid chromatography with ultraviolet detection methodology demonstrated a negative bias for retinol and alpha-tocopherol by the liquid chromatography tandem mass spectrometry method. Analysis of United Kingdom National External Quality Assurance Scheme samples yielded mean bias from the target value of +3.0% for retinol and -11.2% for alpha-tocopherol. We have developed a novel, high-throughput method for extraction of retinol and alpha-tocopherol from human serum followed by simultaneous quantitation by liquid chromatography tandem mass spectrometry. The method offers a rapid, sensitive, specific and cost-effective alternative to high-performance liquid chromatography with

  5. A Focused Multiple Reaction Monitoring (MRM) Quantitative Method for Bioactive Grapevine Stilbenes by Ultra-High-Performance Liquid Chromatography Coupled to Triple-Quadrupole Mass Spectrometry (UHPLC-QqQ).

    PubMed

    Hurtado-Gaitán, Elías; Sellés-Marchart, Susana; Martínez-Márquez, Ascensión; Samper-Herrero, Antonio; Bru-Martínez, Roque

    2017-03-07

    Grapevine stilbenes are a family of polyphenols which derive from trans -resveratrol having antifungal and antimicrobial properties, thus being considered as phytoalexins. In addition to their diverse bioactive properties in animal models, they highlight a strong potential in human health maintenance and promotion. Due to this relevance, highly-specific qualitative and quantitative methods of analysis are necessary to accurately analyze stilbenes in different matrices derived from grapevine. Here, we developed a rapid, sensitive, and specific analysis method using ultra-high-performance liquid chromatography coupled to triple-quadrupole mass spectrometry (UHPLC-QqQ) in MRM mode to detect and quantify five grapevine stilbenes, trans -resveratrol, trans -piceid, trans -piceatannol, trans -pterostilbene, and trans -ε-viniferin, whose interest in relation to human health is continuously growing. The method was optimized to minimize in-source fragmentation of piceid and to avoid co-elution of cis -piceid and trans -resveratrol, as both are detected with resveratrol transitions. The applicability of the developed method of stilbene analysis was tested successfully in different complex matrices including cellular extracts of Vitis vinifera cell cultures, reaction media of biotransformation assays, and red wine.

  6. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    USDA-ARS?s Scientific Manuscript database

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  7. Determination of apalcillin and its metabolites in human body fluids by high-pressure liquid chromatography.

    PubMed Central

    Borner, K; Lode, H; Elvers, A

    1982-01-01

    We describe two methods for the quantitative analysis of apalcillin and its metabolites in serum and urine by reverse-phase high-pressure liquid chromatography (HPLC), a fast isocratic method for the parent drug, and a gradient method that allows the simultaneous assay of two metabolites. Serum was deproteinized with acetonitrile, and urine was diluted with buffer solution. The detection limit was about 0.5 micrograms/ml at a detection wavelength of 254 nm and 1.5 micrograms/ml at 310 nm. Within-batch precision (coefficient of variation) varied from 10.2 to 1.1% for concentrations of 7.8 and 185.3 micrograms/ml of serum, respectively. Recovery rates of 95.1 and 97.7% were found in spiked sera. Results obtained by HPLC correlated well with those from a standard microbiological assay (agar diffusion test); the resulting bivariate regression equation for serum was y-bioassay = 2.5 micrograms/ml + 0.992 X xHPLC, and that for urine was ybioassay = 12.0 micrograms/ml + 1.009 X xHPLC. At a detection wavelength of 315 nm, no interferences were observed in 10 healthy volunteers. Healthy subjects who were given 2 g of apalcillin intravenously excreted 18% of the parent drug within 24 h in the urine. Two inactive compounds were furthermore identified in urine as the isomeric forms of the penicilloic acids. Their excretion within 24 h amounted to 6.9 and 11.2% of the dose. PMID:6818901

  8. Development of an ultra high performance liquid chromatography method for determining triamcinolone acetonide in hydrogels using the design of experiments/design space strategy in combination with process capability index.

    PubMed

    Oliva, Alexis; Monzón, Cecilia; Santoveña, Ana; Fariña, José B; Llabrés, Matías

    2016-07-01

    An ultra high performance liquid chromatography method was developed and validated for the quantitation of triamcinolone acetonide in an injectable ophthalmic hydrogel to determine the contribution of analytical method error in the content uniformity measurement. During the development phase, the design of experiments/design space strategy was used. For this, the free R-program was used as a commercial software alternative, a fast efficient tool for data analysis. The process capability index was used to find the permitted level of variation for each factor and to define the design space. All these aspects were analyzed and discussed under different experimental conditions by the Monte Carlo simulation method. Second, a pre-study validation procedure was performed in accordance with the International Conference on Harmonization guidelines. The validated method was applied for the determination of uniformity of dosage units and the reasons for variability (inhomogeneity and the analytical method error) were analyzed based on the overall uncertainty. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Metabolic profiling of nuciferine in rat urine, plasma, bile and feces after oral administration using ultra-high performance liquid chromatography-diode array detection-quadrupole time-of-flight mass spectrometry.

    PubMed

    Wu, Xiao-Lei; Wu, Ming-Jiang; Chen, Xin-Ze; Ma, Hao-Ling; Ding, Li-Qin; Qiu, Feng; Pan, Qin; Zhang, De-Qin

    2017-06-05

    Nuciferine, a major alkaloid found in Nelumbinis Folium, exhibits a broad spectrum of bioactivities, such as antiobesity, anti-diabetes and anti-inflammatory. However, many research regarding nuciferine focused on the extraction, isolation and biological activity, the metabolism is not comprehensively explained in vivo. Thence, the present of this paper is to establish a simple method for speculating metabolites of nuciferine. A total of 15 metabolites were detected and tentatively identified through ultra high performance liquid chromatography-diode array detection-quadrupole time-of-flight mass spectrometry (UHPLC-DAD-QTOF-MS), including 7 new metabolites. Among them, we also discovered a previously unmentioned metabolically active site at the C 1 -OCH 3 position. These metabolites suggested that demethylation, oxidation, glucuronidation and sulfation were major metabolic pathways. This study provided significant experiment basis for its safety estimate and valuable information about the metabolism of nuciferine, which will be advantageous for new drug development. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A High Pressure Pulsed Expansion Valve for Gases, Liquids, and Supercritical Fluids

    NASA Astrophysics Data System (ADS)

    Köster, C.; Grotemeyer, J.; Schlag, E. W.

    1990-12-01

    A novel design of a pulsed valve for coupling chromatographic techniques with gaseous and liquid mobile phases to a time-of-flight mass spectrometer with multiphoton ionization (MUPI) is presented. The valve can be operated in low pressure regions ( <10 bar) up to temperatures of 350 °C and at higher pressures (300 bar) up to temperatures of 200 °C. Pulse widths lower than 100 μs could be measured. First results demonstrate the ability of interfacing of liquid chromatography to MUPI-mass spectrometry. Additional coupling of CO2-laser desorption to the valve allows the interface to be used for mass spectrometric measurements of nonvolatile biomolecules.

  11. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    PubMed

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Chemical profiling and quantification of Dan-Deng-Tong-Nao-capsule using ultra high performance liquid chromatography coupled with high resolution hybrid quadruple-orbitrap mass spectrometry.

    PubMed

    Lv, Xiao-Jing; Sun, Zhi; Wang, Pei-Le; Yang, Jing; Xu, Tan-Ye; Jia, Qing-Quan; Li, Da-Wei; Su, Fang-Yi; Zhu, Zhen-Feng; Kang, Jian; Zhang, Xiao-Jian

    2018-01-30

    Dan-Deng-Tong-Nao capsule (DDTN) was a traditional Chinese medicine (TCM) formula, and has been widely used for the treatment of stroke clinically which caused by blood stasis. However, the bioactive substances and mechanism are unclear because of the complex compositions in DDTN. In this research, An ultra high-performance liquid chromatography (UHPLC) coupled with hybrid quadruple-orbitrap mass spectrometry (Q-Orbitrap MS) method was utilized to identify the chemical constituents of DDTN. In total, 102 compounds including diterpenes, lactones, flavonoids, and phenolic acids were identified by the accurate masses and fragmentation pathways, and 18 of them were unambiguously determined by comparison of reference standards. Besides, 12 representative compounds were simultaneously quantification analyzed and successfully applified for detecting in 9 batches of DDTN samples by UHPLC-Q-Orbitrap MS in parallel reaction monitoring (PRM) mode. The proposed approach was validated to be satisfied in terms of linearity (0.9954-0.9999), LOD (0.771ng/mL), LOQ (2.568ng/mL), intra-day precision ( <2.68%), inter-day precision ( <4.52%), repeatability ( <2.96%), stability ( <3.21%), and recovery (94.6-105.5%). The results indicate that the method of combining UHPLC with Q-Orbitrap MS is practical and efficient for the chemical clarification in DDTN, and has great potential for the integrating quality control of other traditional Chinese medicines. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Nanotechnology and chip level systems for pressure driven liquid chromatography and emerging analytical separation techniques: a review.

    PubMed

    Lavrik, N V; Taylor, L T; Sepaniak, M J

    2011-05-23

    Pressure driven liquid chromatography (LC) is a powerful and versatile separation technique particularly suitable for differentiating species present in extremely small quantities. This paper briefly reviews main historical trends and focuses on more recently developed technological approaches in miniaturization and on-chip integration of LC columns. The review emphasizes enabling technologies as well as main technological challenges specific to pressure driven separations and highlights emerging concepts that could ultimately overcome fundamental limitations of conventional LC columns. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less

  15. Direct determination of fatty acid esters of 3-chloro-1, 2-propanediol in edible vegetable oils by isotope dilution - ultra high performance liquid chromatography - triple quadrupole mass spectrometry.

    PubMed

    Li, Heli; Chen, Dawei; Miao, Hong; Zhao, Yunfeng; Shen, Jianzhong; Wu, Yongning

    2015-09-04

    A selective and sensitive ultra-high performance liquid chromatography - triple quadrupole mass spectrometry (UHPLC-MS/MS) method coupled with matrix solid phase dispersion (MSPD) extraction was developed for the direct determination of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD esters) in edible vegetable oils. The method integrated the isotope dilution technique, MSPD extraction and UHPLC - MS/MS analysis with multi-reaction monitoring mode (MRM). Matrix-matched calibration curves showed good linearity within the range of 0.01-10mgL(-1) with the correlation coefficient not less than 0.999. Limits of detection (LODs) and limit of quantification (LOQs) of the 3-MCPD esters fell into the range of 0.0001-0.02mgkg(-1) and 0.0004-0.05mgkg(-1), respectively. The recoveries for the spiked extra virgin olive oils ranged from 94.4% to 108.3%, with the relative standard deviations (RSD) ranging from 0.6% to 10.5%. The method was applied for the oil sample (T2642) of the official Food Analysis Performance Assessment Scheme (FAPAS) in 2014 and other real samples from supermarket, and the results showed that the present method was comparative to the gas chromatography-mass spectrometry (GC-MS) method based on the improved German Society for Fat Science (DGF) standard method C-III 18 (09) except for palm oil. Copyright © 2015. Published by Elsevier B.V.

  16. Bile acid profiling and quantification in biofluids using ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Sarafian, Magali H; Lewis, Matthew R; Pechlivanis, Alexandros; Ralphs, Simon; McPhail, Mark J W; Patel, Vishal C; Dumas, Marc-Emmanuel; Holmes, Elaine; Nicholson, Jeremy K

    2015-10-06

    Bile acids are important end products of cholesterol metabolism. While they have been identified as key factors in lipid emulsification and absorption due to their detergent properties, bile acids have also been shown to act as signaling molecules and intermediates between the host and the gut microbiota. To further the investigation of bile acid functions in humans, an advanced platform for high throughput analysis is essential. Herein, we describe the development and application of a 15 min UPLC procedure for the separation of bile acid species from human biofluid samples requiring minimal sample preparation. High resolution time-of-flight mass spectrometry was applied for profiling applications, elucidating rich bile acid profiles in both normal and disease state plasma. In parallel, a second mode of detection was developed utilizing tandem mass spectrometry for sensitive and quantitative targeted analysis of 145 bile acid (BA) species including primary, secondary, and tertiary bile acids. The latter system was validated by testing the linearity (lower limit of quantification, LLOQ, 0.25-10 nM and upper limit of quantification, ULOQ, 2.5-5 μM), precision (≈6.5%), and accuracy (81.2-118.9%) on inter- and intraday analysis achieving good recovery of bile acids (serum/plasma 88% and urine 93%). The ultra performance liquid chromatography-mass spectrometry (UPLC-MS)/MS targeted method was successfully applied to plasma, serum, and urine samples in order to compare the bile acid pool compositional difference between preprandial and postprandial states, demonstrating the utility of such analysis on human biofluids.

  17. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  18. Soft x-ray spectroscopy of high pressure liquid.

    PubMed

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; Macdougall, James; Pepper, John; Armitage, Kevin; Borsos, Jason; Knauss, Kevin G; Lee, Namhey; Allézy, Arnaud; Gilbert, Benjamin; MacDowell, Alastair A; Liu, Yi-Sheng; Glans, Per-Anders; Sun, Xuhui; Chao, Weilun; Guo, Jinghua

    2018-01-01

    We describe a new experimental technique that allows for soft x-ray spectroscopy studies (∼100-1000 eV) of high pressure liquid (∼100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3 N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3 N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3 N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length of the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3 N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3 N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (∼350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.

  19. Soft x-ray spectroscopy of high pressure liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei

    Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less

  20. Soft x-ray spectroscopy of high pressure liquid

    DOE PAGES

    Qiao, Ruimin; Xia, Yujian; Feng, Xuefei; ...

    2018-01-01

    Here, we describe a new experimental technique that allows for soft x-ray spectroscopy studies (~100-1000 eV) of high pressure liquid (~100 bars). We achieve this through a liquid cell with a 100 nm-thick Si 3N 4 membrane window, which is sandwiched by two identical O-rings for vacuum sealing. The thin Si 3N 4 membrane allows soft x-rays to penetrate, while separating the high-pressure liquid under investigation from the vacuum required for soft x-ray transmission and detection. The burst pressure of the Si 3N 4 membrane increases with decreasing size and more specifically is inversely proportional to the side length ofmore » the square window. It also increases proportionally with the membrane thickness. Pressures > 60 bars could be achieved for 100 nm-thick square Si 3N 4 windows that are smaller than 65 μm. However, above a certain pressure, the failure of the Si wafer becomes the limiting factor. The failure pressure of the Si wafer is sensitive to the wafer thickness. Moreover, the deformation of the Si 3N 4 membrane is quantified using vertical scanning interferometry. As an example of the performance of the high-pressure liquid cell optimized for total-fluorescence detected soft x-ray absorption spectroscopy (sXAS), the sXAS spectra at the Ca L edge (~350 eV) of a CaCl 2 aqueous solution are collected under different pressures up to 41 bars.« less

  1. Methanol adducts leading to the identification of a reactive aldehyde metabolite of CPAQOP in human liver microsomes by ultra-high-performance liquid chromatography/mass spectrometry.

    PubMed

    Martin, Scott; Lenz, Eva M; Smith, Robin; Temesi, David G; Orton, Alexandra L; Clench, Malcolm R

    2017-01-15

    The incubation of CPAQOP (1-[(2R)-2-[[4-[3-chloro-4-(2-pyridyloxy)anilino]quinazolin-5-yl]oxymethyl]-1-piperidyl]-2-hydroxy) with human liver microsomes generated several metabolites that highlighted the hydroxyacetamide side chain was a major site of metabolism for the molecule. The metabolites were derived predominantly from oxidative biotransformations; however, two unexpected products were detected by liquid chromatography/ultraviolet/mass spectrometry (LC/UV/MS) and identified as methanol adducts. This observation prompted further LC/MS investigations into their formation. Three separate incubations of CPAQOP were conducted in human liver microsomes; Naïve, fortified with methoxyamine and fortified with glutathione. Separation was achieved via ultra-high-performance liquid chromatography with either methanol or acetonitrile gradients containing formic acid. MS analysis was conducted by electrospray ionisation LTQ Orbitrap mass spectrometry acquiring accurate mass full scan, data-dependent MS 2 and all ion fragmentation. No methanol adducts were detected by MS when acetonitrile was used in the mobile phase instead of methanol, verifying that a metabolite was reacting with methanol on column. Although this reactive metabolite could not be isolated or structurally characterised by LC/MS directly, product ion spectra of the methanol adducts confirmed addition of methanol on the hydroxyacetamide side chain. Additional experiments using methoxyamine showed the disappearance of the two methanol adducts and appearance of a methoxyamine adduct, confirming the presence of an aldhyde. Product ion spectra of the methoxyamine adduct confirmed addition of methoxyamine to the hydroxyacetamide side chain. The proposed bioactivation of CPAQOP occurred via the reactive aldehyde intermediate, which readily reacted with methanol in the mobile phase to form a pair of isomeric hemiacetal methanol adducts. In acidified methanol the equilibrium favoured the methanol adduct and in

  2. Sensitive high-performance liquid chromatography/mass spectrometry method for determination of steviol in rat plasma.

    PubMed

    Wang, L Z; Goh, B C; Fan, L; Lee, H S

    2004-01-01

    The main toxicological concern of stevioside, a highly potent sweetener from S. rebaudiana, is its main metabolite, steviol. To determine very low levels of steviol in in vivo experiments, a sensitive liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) method was developed for quantifying steviol in rat plasma after oral administration of a single dose of stevioside (0.5 g/kg). The sample preparation uses liquid-liquid extraction with tert-butyl methyl ether in an acidic environment. The retention time of steviol was 10.5 min. The assay was linear over the range 2-1000 ng/mL with a lower limit of detection of 1 ng/mL. The intra- and inter-day precision were <5 and <7%, respectively, and the accuracy was in the range 95-108%. The steviol concentration profile in rat plasma was determined. Copyright 2003 John Wiley & Sons, Ltd.

  3. Strategy for Comprehensive Profiling and Identification of Acidic Glycosphingolipids Using Ultra-High-Performance Liquid Chromatography Coupled with Quadrupole Time-of-Flight Mass Spectrometry.

    PubMed

    Hu, Ting; Jia, Zhixin; Zhang, Jin-Lan

    2017-07-18

    Acidic glycosphingolipids (AGSLs), which mainly consist of ganglioside and sulfatide moieties, are highly concentrated in the central nervous system. Comprehensive profiling of AGSLs has historically been challenging because of their high complexity and the lack of standards. In this study, a novel strategy was developed to comprehensively profile AGSLs using ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry. Ganglioside isomers with different glycan chains such as GD1a/GD1b were completely separated on a C18 column for the first time to our knowledge, facilitated by the addition of formic acid in the mobile phase. A mathematical model was established to predict the retention times (RTs) of all theoretically possible AGSLs on the basis of the good logarithmic relationship between the ceramide carbon numbers of the AGSLs in the reference material and their RTs. A data set was created of 571 theoretically possible AGSLs, including the ceramide carbon numbers, RTs, and high-resolution quasi-molecular ions. A novel fast identification strategy was established for global AGSL profiling by comparing the high-resolution quasi-molecular ions and RTs of the tested peaks to those in the data set of 571 AGSLs. Using this strategy, 199 AGSL candidates were identified in rat brain tissue. MS/MS fragments were further collected for these 199 candidates to confirm their identity as AGSLs. This novel strategy was employed to profile AGSLs in brain tissue samples from control rats and model rats with bilateral common carotid artery (2-VO) cerebral ischemia. Forty AGSLs were significantly different between the control and model groups, and these differences were further interpreted.

  4. Identification of substances migrating from plastic baby bottles using a combination of low-resolution and high-resolution mass spectrometric analysers coupled to gas and liquid chromatography.

    PubMed

    Onghena, Matthias; Van Hoeck, Els; Van Loco, Joris; Ibáñez, María; Cherta, Laura; Portolés, Tania; Pitarch, Elena; Hernandéz, Félix; Lemière, Filip; Covaci, Adrian

    2015-11-01

    This work presents a strategy for elucidation of unknown migrants from plastic food contact materials (baby bottles) using a combination of analytical techniques in an untargeted approach. First, gas chromatography (GC) coupled to mass spectrometry (MS) in electron ionisation mode was used to identify migrants through spectral library matching. When no acceptable match was obtained, a second analysis by GC-(electron ionisation) high resolution mass spectrometry time of flight (TOF) was applied to obtain accurate mass fragmentation spectra and isotopic patterns. Databases were then searched to find a possible elemental composition for the unknown compounds. Finally, a GC hybrid quadrupole-TOF-MS with an atmospheric pressure chemical ionisation source was used to obtain the molecular ion or the protonated molecule. Accurate mass data also provided additional information on the fragmentation behaviour as two acquisition functions with different collision energies were available (MS(E) approach). In the low-energy function, limited fragmentation took place, whereas for the high-energy function, fragmentation was enhanced. For less volatile unknowns, ultra-high pressure liquid chromatography-quadrupole-TOF-MS was additionally applied. Using a home-made database containing common migrating compounds and plastic additives, tentative identification was made for several positive findings based on accurate mass of the (de)protonated molecule, product ion fragments and characteristic isotopic ions. Six illustrative examples are shown to demonstrate the modus operandi and the difficulties encountered during identification. The combination of these techniques was proven to be a powerful tool for the elucidation of unknown migrating compounds from plastic baby bottles. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Effect of ultra-high pressure on small animals, tardigrades and Artemia

    NASA Astrophysics Data System (ADS)

    Ono, Fumihisa; Mori, Yoshihisa; Takarabe, Kenichi; Fujii, Akiko; Saigusa, Masayuki; Matsushima, Yasushi; Yamazaki, Daisuke; Ito, Eiji; Galas, Simon; Saini, Naurang L.

    2016-12-01

    This research shows that small animals, tardigrades (Milnesium tardigradum) in tun (dehydrated) state and Artemia salina cists (dried eggs) can tolerate the very high hydrostatic pressure of 7.5 GPa. It was really surprising that living organisms can survive after exposure to such a high pressure. We extended these studies to the extremely high pressure of 20 GPa by using a Kawai-type octahedral anvil press. After exposure to this pressure for 30 min, the tardigrades were soaked in pure water and investigated under a microscope. Their bodies regained metabolic state and no serious injury could be seen. But they were not alive. A few of Artemia eggs went part of the way to hatching after soaked in sea water, but they never grew any further. Comparing with the case of blue-green alga, these animals are weaker under ultra-high pressure.

  6. Use of High-Pressure Liquid Chromatography to Determine Plasma Levels of Metronidazole and Metabolites After Intravenous Administration

    PubMed Central

    Wheeler, L. A.; De Meo, M.; Halula, M.; George, L.; Heseltine, P.

    1978-01-01

    A rapid and sensitive high-pressure liquid chromatography assay for metronidazole and its two principle metabolites, 1-(2-hydroxyethyl-2-hydroxymethyl)-5-nitro-imidazole [hydroxy metabolite] and 1-acetic acid-2-methyl-5-metronidazole [acid metabolite], was developed. The retention times observed were 5.7, 3.3, and 4.5 min, respectively. A reverse-phase μC18 Bondapak column using a solvent system of methanol, acetonitrile, and 0.005 M pH 4 potassium dihydrogen phosphate (4:3:93, vol/vol) was used to achieve separation of the three compounds. Patients receiving metronidazole therapy were given a loading dose of 13.6 mg of drug per kg intravenously over 1 h, followed by a maintenance dose of 1.43 mg/kg per h. The range of metronidazole concentrations observed was 6.8 to 47.5 μg/ml. These levels are well above the minimal inhibitory concentrations of most clinically significant anaerobic bacteria including Bacteroides fragilis. Little of the acid metabolite was observed in the plasma. The concentration of hydroxy metabolite ranged from 1.6 to 16 μg/ml. The latter may represent an additional source of antimicrobial activity since the hydroxy metabolite has approximately 30% the biological activity of metronidazole. PMID:646342

  7. Separation of enantiomers of new psychoactive substances by high-performance liquid chromatography.

    PubMed

    Kadkhodaei, Kian; Forcher, Lisa; Schmid, Martin G

    2018-03-01

    New psychoactive substances are defined as compounds with consciousness-changing effects and have been developed simultaneously with classical drugs. They arise through structural modifications of illegal substances and are mainly produced to circumvent laws. Availability is simple, since new psychoactive substances can be purchased from the Internet. Among them many chemical drug compound classes are chiral and thus the two resulting enantiomers can differ in their effects. The aim of this study is to develop a suitable chiral high-performance liquid chromatography separation method for a broad spectrum of new psychoactive substances using cellulose tris(3,5-dichlorophenylcarbamate) as a chiral selector. Experiments were performed by high-performance liquid chromatography in normal-phase mode under isocratic conditions using ultraviolet detection. Direct separation was carried out on a high-performance liquid chromatography column (Lux® i-Cellulose-5, 3.5 μm, Phenomenex®), available since 2016. Excellent separation results were obtained for cathinones. After further optimization, even 47 instead of 39 out of 52 cathinones showed baseline separation. For amphetamine derivatives, satisfactory results were not achieved. Further, new psychoactive substances from other compound classes such as benzofuranes, thiophenes, phenidines, phenidates, morpholines, and ketamines were partially resolved, depending on the polarity and degree of substitution. All analytes, which were mainly purchased from the Internet, were proven to be traded as racemates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. An Inexpensive Liquid Chromatography Apparatus for Undergraduate Teaching.

    ERIC Educational Resources Information Center

    McCamish, Malcolm; And Others

    1982-01-01

    Describes an inexpensive, low-pressure liquid chromatography pump, slurry filler, stainless steel columns, and injector system suitable for the undergraduate laboratory or routine analysis. Includes sectional diagram of the pump and construction diagram of the preparative columns. (Author/SK)

  9. Repeatability of gradient ultrahigh pressure liquid chromatography-tandem mass spectrometry methods in instrument-controlled thermal environments.

    PubMed

    Grinias, James P; Wong, Jenny-Marie T; Kennedy, Robert T

    2016-08-26

    The impact of viscous friction on eluent temperature and column efficiency in liquid chromatography is of renewed interest as the need for pressures exceeding 1000bar to use with columns packed with sub-2μm particles has grown. One way the development of axial and radial temperature gradients that arise due to viscous friction can be affected is by the thermal environment the column is placed in. In this study, a new column oven integrated into an ultrahigh pressure liquid chromatograph that enables both still-air and forced-air operating modes is investigated to find the magnitude of the effect of the axial thermal gradient that forms in 2.1×100mm columns packed with sub-2μm particles in these modes. Temperature increases of nearly 30K were observed when the generated power of the column exceeded 25W/m. The impact of the heating due to viscous friction on the repeatability of peak capacity, elution time, and peak area ratio to an internal standard for a gradient UHPLC-MS/MS method to analyze neurotransmitters was found to be limited. This result indicates that high speed UHPLC-MS/MS gradient methods under conditions of high viscous friction may be possible without the negative effects typically observed with isocratic separations under similar conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Assessing the detectability of antioxidants in two-dimensional high-performance liquid chromatography.

    PubMed

    Bassanese, Danielle N; Conlan, Xavier A; Barnett, Neil W; Stevenson, Paul G

    2015-05-01

    This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. [Determination of 49 drugs and 5 metabolites in drinking water samples using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry].

    PubMed

    Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming

    2015-07-01

    A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.

  12. Metabolomic analysis of swine urine treated with β2-agonists by ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry.

    PubMed

    Wu, Yuping; Bi, Yanfeng; Bingga, Gali; Li, Xiaowei; Zhang, Suxia; Li, Jiancheng; Li, Hui; Ding, Shuangyang; Xia, Xi

    2015-06-26

    The illegal use of β2-agonists in livestock production was previously detected by efficient methods based on mass spectrometry to control the residues of these drugs. Nevertheless, such methods still remain a challenging task for authorities who monitor these residues because the use of "cocktails" composed of mixtures of low amounts of several substances as well as the synthesis of new compounds of unknown structure prevent efficient prevention of illegal use of growth-promoting agents. Here, we outlined a metabolomics-based strategy for detecting the use of "cocktails" composed of mixtures of low amounts of three β2-agonists via urine profiling. Urine profiles of controls and swine treated with mixture of low amounts of three substances (clenbuterol, salbutamol, and ractopamine) were analyzed with ultra-high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. The metabolic differences between controls and β2-agonists-treated groups were compared using multivariate data analysis. Fourteen metabolites were identified related with the β2-agonists treatment, while two co-biomarkers, 2-indolecarboxylic acid and fluorometholone acetate, either in single or "cocktails" of low-dose mixture of clenbuterol, salbutamol, and ractopamine, could be considered as diagnostic markers for the detection of illegal use of β2-agonists. The results of depletion study demonstrated that it is practical to use the markers for monitoring of β2-agonists. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Characterization and profiling of phenolic amides from Cortex Lycii by ultra-high performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry.

    PubMed

    Zhang, Jingxian; Guan, Shuhong; Sun, Jianghao; Liu, Tian; Chen, Pei; Feng, Ruihong; Chen, Xin; Wu, Wanying; Yang, Min; Guo, De-An

    2015-01-01

    Cortex Lycii, the root bark of Lycium chinense Mill. or Lycium barbarum L., is a frequently used traditional Chinese medicine. Phytochemical studies have shown that phenolic amides are not only characteristic compounds but also abundant ones in this plant. In the present study, an effective method was developed for structural characterization of phenolic amides from Cortex Lycii by ultra-high performance liquid chromatography coupled with linear ion trap Orbitrap tandem mass spectrometry. The fragmentation of 14 compounds including six cinnamic acid amides, six neolignanamides, and two lignanamides were studied systematically for the first time. It was found that, in the positive ion mode, neutral loss of the tyramide moiety (137 Da) or N-(4-aminobutyl)acetamide moiety (130 Da) were characteristic for these compounds. At least 54 phenolic amides were detected in the extract and 48 of them were characterized, among which 14 known compounds were identified unambiguously by comparing the retention time and mass spectra with those of reference compounds, and 34 components were tentatively identified based on the fragmentation patterns, exact mass, UV spectra, as well as retention time. Fifteen compounds were characterized as potential new ones. Additionally, the developed method was applied to analyze eight batches of samples collected from the northwest of China, and it was found that cinnamic acid amides were the main type of phenolic amides in Cortex Lycii. In conclusion, the identification of these chemicals provided essential data for further phytochemical studies, metabolites identification, and the quality control of Cortex Lycii.

  14. Ultrasonic Sound Velocity of Diopside Liquid Under High Pressure and High Temperature Conditions

    NASA Astrophysics Data System (ADS)

    Xu, M.; Jing, Z.; Chantel, J.; Yu, T.; Wang, Y.; Jiang, P.

    2017-12-01

    The equation of state (EOS) of silicate liquids is of great significance to the understanding of the dynamics and differentiation of the magmatic systems in Earth and other terrestrial planets. Sound velocity of silicate liquids measured at high pressure can provide direct information on the bulk modulus and its pressure derivative and hence tightly constrain the EOS of silicate liquids. In addition, the sound velocity data can be directly compared to seismic observations to infer the presence of melts in the mantle. While the sound velocity for silicate liquids at ambient pressure has been well established, the high-pressure sound velocity data are still lacking due to experimental challenges. In this study, we successfully determined the sound velocities of diopside (CaMgSi2O6) liquid in a multi-anvil apparatus under high pressure-high temperature conditions from 1 to 4 GPa and 1973 to 2473 K by the ultrasonic interferometry in conjunction with synchrotron X-ray techniques. Diopside was chosen to study because it is not only one of the most important phases in the Earth's upper mantle, but also an end-member composition of model basalt. It is thus an ideal simplified melt composition in the upper mantle. Besides, diopside liquid has been studied by ambient-pressure ultrasonic measurements (e.g., Ai and Lange, 2008) and shock-wave experiments at much higher pressure (e.g., Asimow and Ahrens, 2010), which allows comparison with our results over a large pressure range. Our high-pressure results on the sound velocity of Di liquid are consistent with the ambient-pressure data and show an increase of velocity with pressure (from 3039 m/s at 0.1 GPa to 4215 m/s at 3.5 GPa). Fitting to the Murnaghan EOS gives an isentropic bulk modulus (Ks) of 24.8 GPa and its pressure dependence (K'S) of 7.8. These are consistent with the results from shock-wave experiments on Di liquid (Asimow and Ahrens, 2010), indicating that the technique used in this study is capable to accurately

  15. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    PubMed

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Rapid amino acid quantitation with pre-column derivatization; ultra-performance reverse phase liquid chromatography and single quadrupole mass spectrometry.

    PubMed

    Pretorius, Carel J; McWhinney, Brett C; Sipinkoski, Bilyana; Wilce, Alice; Cox, David; McWhinney, Avis; Ungerer, Jacobus P J

    2018-03-01

    We optimized a quantitative amino acid method with pre-column derivatization, norvaline (nva) internal standard and reverse phase ultra-performance liquid chromatography by replacing the ultraviolet detector with a single quadrupole mass spectrometer (MS nva ). We used 13 C 15 N isotopically labeled amino acid internal standards and a C18 column with 1.6μm particles to optimize the chromatography and to confirm separation of isobaric compounds (MS lis ). We compared the analytical performance of MS nva with MS lis and the original method (UV nva ) with clinical samples. The chromatography time per sample of MS nva was 8min, detection capabilities were <1μmol/L for most components, intermediate imprecisions at low concentrations were <10% and there was negligible carryover. MS nva was linear up to a total amino acid concentration in a sample of approximately 9500μmol/L. The agreements between most individual amino acids were satisfactory compared to UV nva with the latter prone to outliers and suboptimal quantitation of urinary arginine, aspartate, glutamate and methionine. MS nva reliably detected argnininosuccinate, β-alanine, citrulline and cysteine-s-sulfate. MS nva resulted in a more than fivefold increase in operational efficiency with accurate detection of amino acids and metabolic intermediates in clinical samples. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  17. Effects of the ultra-high pressure on structure and α-glucosidase inhibition of polysaccharide from Astragalus.

    PubMed

    Zhu, Zhen-Yuan; Luo, You; Dong, Guo-Ling; Ren, Yuan-Yuan; Chen, Li-Jing; Guo, Ming-Zhu; Wang, Xiao-Ting; Yang, Xue-Ying; Zhang, Yongmin

    2016-06-01

    A novel homogeneous polysaccharide fraction (APS) was extracted from Astragalus by hot water and purified by Sephadex G-100 and G-75 column. Its molecular weight was 693kDa. APS and APS with ultra-high pressure treatment exhibited significant inhibitory abilities on a-glucosidase, inhibition rate from high to low in order was 400MPa-APS, 300MPa-APS, 500MPa-APS and APS. The inhibition ​percentage of 400MPa-APS (1.5mg/mL) was 49% (max.). This suggested that the inhibitory activity of APS on a-glucosidase was improved by ultra-high pressure treatment. FT-IR, SEM, CD spectra, atomic force microscope and Congo red test analysis of APS and 400MPa-APS showed ultra-high pressure treatment didn't change the preliminary structure but had an effect on its advanced structure. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Identification and evaluation of the chemical similarity of Yindan xinnaotong samples by ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry fingerprinting.

    PubMed

    Gong, Leilei; Haiyu, Xu; Wang, Lan; Xiaojie, Yin; Huijun, Yuan; Songsong, Wang; Cheng, Long; Ma, Xiaojing; Gao, Shuangrong; Liang, Rixin; Yang, Hongjun

    2016-02-01

    Yindan xinnaotong, a compound preparation used in traditional Chinese medicine, is composed of eight herbs: Ginkgo biloba leaf (yinxingye), Salvia miltiorrhizae (danshen), Herba gynostemmatis (jiaogulan), Erigerontis herba (dengzhanxixin), Allii sativi bulbus (dasuan), Notoginseng radixe rhizoma (sanqi), Crataegi fructus (shanzha), and Borneolum (tianranbingpian). Yindan xinnaotong is primarily used to treat cardiovascular and cerebrovascular diseases. However, to date, no scientific methods have been established to assess the quality of Yindan xinnaotong. Therefore, a combinatorial method was developed based on chemical constituent identification and fingerprint analysis to assess the consistency of Yindan xinnaotong quality. In this study, ultra high performance liquid chromatography coupled with time-of-flight mass spectrometry was used to identify the chemical components of Yindan xinnaotong soft capsules. Approximately 74 components were detected, of which 70, including flavonoids, ginkgolide, phenolic acid, diterpenoid tanshinones, and ginsenoside, were tentatively identified. A fingerprint analysis was also conducted to evaluate the uniformity of the quality of Yindan xinnaotong soft capsules. Ten batches of Yindan xinnaotong soft capsules were analyzed. All of the resulting chromatograms were imported into the "Similarity Evaluation System for Chromatographic Fingerprints of TCM" (Chinese Pharmacopoeia Commission, version 2004A). The similarity scores of common peaks from these samples ranged from 0.903-1.000, indicating that samples from different batches were highly correlated. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Determination of 15 N-nitrosodimethylamine precursors in different water matrices by automated on-line solid-phase extraction ultra-high-performance-liquid chromatography tandem mass spectrometry.

    PubMed

    Farré, Maria José; Insa, Sara; Mamo, Julian; Barceló, Damià

    2016-08-05

    A new methodology based on on-line solid-phase extraction (SPE) ultra-high-performance-liquid chromatography coupled to a triple quadrupole mass spectrometer (UHPLC-MS-MS) for the determination of 15 individual anthropogenic N-nitrosodimethylamine (NDMA) precursors was developed. On-line SPE was performed by passing 2mL of the water sample through a Hypersil GOLD aQ column and chromatographic separation was done using a Kinetex Biphenyl column using methanol and 0.1% formic acid aqueous solution as a mobile phase. For unequivocal identification and confirmation, two selected reaction monitoring (SRM) transitions were monitored per compound. Quantification was performed by internal standard approach and matrix match calibration. The main advantages of the developed method are high sensitivity (limits of detection in the sub ng/L range), selectivity due to the use of tandem mass spectrometry, precision and minimum sample manipulation as well as fast analytical response. Process efficiency and recovery were also evaluated for all the target compounds. As part of the validation procedure, the method was applied in a sampling campaign for the analysis of influent and secondary effluent of a wastewater treatment plant (WWTP) in Girona, Spain. Additionally, the effluent from a nanofiltration (NF) membrane system used for water recycling was monitored. The percentage of NDMA formation explained by the measured precursors was also quantified. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Application of characteristic ion filtering with ultra-high performance liquid chromatography quadrupole time of flight tandem mass spectrometry for rapid detection and identification of chemical profiling in Eucommia ulmoides Oliv.

    PubMed

    He, Mingzhen; Jia, Jia; Li, Junmao; Wu, Bei; Huang, Wenping; Liu, Mi; Li, Yan; Yang, Shilin; Ouyang, Hui; Feng, Yulin

    2018-06-15

    Efficient targeted identification of chemical constituents from traditional Chinese medicine is still a major challenge. In this study, we used a characteristic ion filtering strategy to characterize compounds of Eucommia ulmoides Oliv. by ultra-high performance liquid chromatography quadrupole time of flight tandem mass spectrometry (UHPLC-ESI-Q-TOF-MS/MS). By using the ion filtering approach, target constituents of Eucommia ulmoides Oliv. were easily tentatively identified from the enormous LC/MS data set. The strategy consisted of the following three steps: 1) To establishing a characteristic ion database by diagnostic product ions or neutral loss fragments; 2) To evaluate the structural information of the compounds by high-resolution diagnostic characteristic ion filtering; 3) To confirm the different classes by chemical profiling according to their MS/MS spectra. In this study, characteristic ions are summarized as five major groups of compounds in Eucommia ulmoides Oliv. In total, 113 compounds were tentatively identified, including 23 potentially novel compounds. The results form a foundation for the quality control and chemical basis of Eucommia ulmoides Oliv. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. High-throughput and simultaneous analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry in the positive and negative ionization modes.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi

    2011-06-01

    In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  2. Determination of steroid hormones and their metabolite in several types of meat samples by ultra high performance liquid chromatography-Orbitrap high resolution mass spectrometry.

    PubMed

    López-García, Marina; Romero-González, Roberto; Garrido Frenich, Antonia

    2018-03-09

    A new analytical method based on ultra-high performance liquid chromatography (UHPLC) coupled to Orbitrap high resolution mass spectrometry (Orbitrap-HRMS) has been developed for the determination of steroid hormones (hydrocortisone, cortisone, progesterone, prednisone, prednisolone, testosterone, melengesterol acetate, hydrocortisone-21-acetate, cortisone-21-acetate, testosterone propionate, 17α-methyltestosterone, 6α-methylprednisolone and medroxyprogesterone) and their metabolite (17α-hydroxyprogesterone) in three meat samples (chicken, pork and beef). Two different extraction approaches were tested (QuEChERS "quick, easy, cheap, effective, rugged and safe" and "dilute and shoot"), observing that the QuEChERS method provided the best results in terms of recovery. A clean-up step was applied comparing several sorbents, obtaining the best results when florisil and aluminum oxide were used. The optimized method was validated, obtaining suitable results for all validation parameters in the three meat matrices evaluated. Recovery values ranged from 70% to 103% (except for prednisone in beef samples), meanwhile repeatability and reproducibility were obtained at values lower than 18% and 21%, respectively. The limit of quantification (LOQ) was established for most of the compounds at 1.0 μg/kg, except for testosterone in chicken and hydrocortisone-21-acetate and cortisone-21-acetate in pork at 2.0 μg/kg. Decision limit (CCα) and detection capability (CCβ) values ranged from 1.0-2.7 μg/kg and 1.9-5.5 μg/kg, respectively, in the three matrices. Finally, thirty one meat samples were analyzed and two hormones, progesterone and hydrocortisone, were detected in a beef and pork sample at 1.7 and 2.8 μg/kg respectively. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. [Determination of arbutin in apple juice concentrate by ultra performance liquid chromatography with electrospray ionization tandem mass spectrometry].

    PubMed

    Kong, Xianghong; He, Qiang; Yue, Aishan; Wu, Shuangmin; Li, Jianhua

    2010-06-01

    An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of arbutin in apple juice concentrate. Samples were diluted with water, then cleaned-up with a PS-DVB column. Quantitation was carried out using an external standard method. UPLC was performed on an Eclipse Plus C, column (100 mm x 2.1 mm, 1.8 microm) using a gradient solvent system (methanol-water). MS/MS was performed with multiple reaction monitoring (MRM) mode. The detection limit of arbutin was 0.02 mg/L. The method showed good linear relationship at the range of 0.04-2.0 mg/L. The recoveries ranged from 75.2% to 102.7% with relative standard deviations (RSDs) less than 8.9%. The method is simple, fast and sensitive. It's suitable for quantitative and qualitative analysis of arbutin in apple juice concentrate.

  4. Quantitative analysis of multiple fatty acid ethanolamides using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lin, Lin; Yang, Haifeng; Jones, Peter J H

    2012-12-01

    Fatty acid ethanolamides (FAE) represent a group of lipid signaling molecules associated with many physiological and pharmacological actions; however, low FAE tissue levels pose challenges in terms of analytical characterization. The objective was to develop a competent ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for analysis of multiple FAE in animal and human tissue samples. Analytes were extracted using lipid-phase and solid-phase extraction procedures. Chromatographic separation was achieved using a gradient elution in 8 min. FAE were quantified by MS/MS in positive electrospray ionization mode. Linearity was shown in lower and higher FAE concentration ranges, with a limit of quantification (LOQ) ≤0.2 ng/ml for FAE including alpha-linolenoylethanolamide (ALEA), arachidonoylethanolamide (AEA), docosahexaenoylethanolamide (DHEA), linoleoylethanolamide (LEA), oleoylethanolamide (OEA) and palmitoylethanolamide (PEA). Accuracy was shown to be between 92.4% and 108.8%, and precision was <10% for all FAE species. In sum, this sensitive and reproducible method can be used to simultaneously determine multiple FAE at low concentrations in order to facilitate further study of the role of FAE on physiological state. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Evaluation of Vapor Pressure and Ultra-High Vacuum Tribological Properties of Ionic Liquids (2) Mixtures and Additives

    NASA Technical Reports Server (NTRS)

    Morales, Wilfredo; Koch, Victor R.; Street, Kenneth W., Jr.; Richard, Ryan M.

    2008-01-01

    Ionic liquids are salts, many of which are typically viscous fluids at room temperature. The fluids are characterized by negligible vapor pressures under ambient conditions. These properties have led us to study the effectiveness of ionic liquids containing both organic cations and anions for use as space lubricants. In the previous paper we have measured the vapor pressure and some tribological properties of two distinct ionic liquids under simulated space conditions. In this paper we will present vapor pressure measurements for two new ionic liquids and friction coefficient data for boundary lubrication conditions in a spiral orbit tribometer using stainless steel tribocouples. In addition we present the first tribological data on mixed ionic liquids and an ionic liquid additive. Post mortem infrared and Raman analysis of the balls and races indicates the major degradation pathway for these two organic ionic liquids is similar to those of other carbon based lubricants, i.e. deterioration of the organic structure into amorphous graphitic carbon. The coefficients of friction and lifetimes of these lubricants are comparable to or exceed these properties for several commonly used space oils.

  6. Liquid Chromatography in 1982.

    ERIC Educational Resources Information Center

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  7. Use of experimental design in the investigation of stir bar sorptive extraction followed by ultra-high-performance liquid chromatography-tandem mass spectrometry for the analysis of explosives in water samples.

    PubMed

    Schramm, Sébastien; Vailhen, Dominique; Bridoux, Maxime Cyril

    2016-02-12

    A method for the sensitive quantification of trace amounts of organic explosives in water samples was developed by using stir bar sorptive extraction (SBSE) followed by liquid desorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The proposed method was developed and optimized using a statistical design of experiment approach. Use of experimental designs allowed a complete study of 10 factors and 8 analytes including nitro-aromatics, amino-nitro-aromatics and nitric esters. The liquid desorption study was performed using a full factorial experimental design followed by a kinetic study. Four different variables were tested here: the liquid desorption mode (stirring or sonication), the chemical nature of the stir bar (PDMS or PDMS-PEG), the composition of the liquid desorption phase and finally, the volume of solvent used for the liquid desorption. On the other hand, the SBSE extraction study was performed using a Doehlert design. SBSE extraction conditions such as extraction time profiles, sample volume, modifier addition, and acetic acid addition were examined. After optimization of the experimental parameters, sensitivity was improved by a factor 5-30, depending on the compound studied, due to the enrichment factors reached using the SBSE method. Limits of detection were in the ng/L level for all analytes studied. Reproducibility of the extraction with different stir bars was close to the reproducibility of the analytical method (RSD between 4 and 16%). Extractions in various water sample matrices (spring, mineral and underground water) have shown similar enrichment compared to ultrapure water, revealing very low matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    PubMed

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  9. Simultaneous quantification of neuroactive dopamine serotonin and kynurenine pathway metabolites in gender-specific youth urine by ultra performance liquid chromatography tandem high resolution mass spectrometry.

    PubMed

    Lu, Haihua; Yu, Jing; Wang, Jun; Wu, Linlin; Xiao, Hang; Gao, Rong

    2016-04-15

    Neuroactive metabolites in dopamine, serotonin and kynurenine metabolic pathways play key roles in several physiological processes and their imbalances have been implicated in the pathophysiology of a wide range of disorders. The association of these metabolites' alterations with various pathologies has raised interest in analytical methods for accurate quantification in biological fluids. However, simultaneous measurement of various neuroactive metabolites represents great challenges due to their trace level, high polarity and instability. In this study, an analytical method was developed and validated for accurately quantifying 12 neuroactive metabolites covering three metabolic pathways in youth urine by ultra performance liquid chromatography coupled to electrospray tandem high resolution mass spectrometry (UPLC-ESI-HRMS/MS). The strategy of dansyl chloride derivatization followed by solid phase extraction on C18 cartridges were employed to reduce matrix interference and improve the extraction efficiency. The reverse phase chromatographic separation was achieved with a gradient elution program in 20 min. The high resolution mass spectrometer (Q Exactive) was employed, with confirmation and quantification by Target-MS/MS scan mode. Youth urine samples collected from 100 healthy volunteers (Female:Male=1:1) were analyzed to explore the differences in metabolite profile and their turnover between genders. The results demonstrated that the UPLC-ESI-HRMS/MS method is sensitive and robust, suitable for monitoring a large panel of metabolites and for discovering new biomarkers in the medical fields. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Determination of boldenone sulfoconjugate and related steroid sulfates in equine urine by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Weidolf, L O; Lee, E D; Henion, J D

    1988-03-01

    Sulfoconjugated anabolic steroids were separated by micro-bore high-performance liquid chromatography. The eluent was introduced into the atmospheric pressure ion source of the triple-quadrupole mass spectrometer via an ion spray liquid chromatograph/mass spectrometer interface operated in the negative ion mode. The limit of detection was 10 pg on-column by selected ion monitoring of the molecular ion and the response increased linearly over a concentration range of 2.4 orders of magnitude. Following work-up by a liquid-solid extraction procedure of equine urine samples, full-scan daughter ion spectra of boldenone sulfate could be obtained up to 17 days after a therapeutic dose of boldenone undecylenate to a horse.

  11. Simultaneous enantioselective determination of phenylpyrazole insecticide flufiprole and its chiral metabolite in paddy field ecosystem by ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Jing; Zhang, Yuting; Cheng, Youpu; Yuan, Shankui; Liu, Lei; Shao, Hui; Li, Hui; Li, Na; Zhao, Pengyue; Guo, Yongze

    2016-03-20

    A novel and sensitive ultra-high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous enantioselective determination of flufiprole and its hydrolysis metabolite in paddy field ecosystem. The separation and determination were performed using reversed-phase chromatography on a novel cellulose chiral stationary phase, a Lux Cellulose-4 (150 mm × 2.0 mm) column, under isocratic conditions at 0.25 mL/min flow rate. The effects of other four different polysaccharide-based chiral stationary phases (CSPs) on the separation and simultaneous enantioseparation of the two target compounds were also evaluated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. Modified QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the enrichment and cleanup of paddy water, rice straw, brown rice and paddy soil samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under the optimal conditions, the mean recoveries for all enantiomers from the above four sample matrix were ranged from 83.6% to 107%, with relative standard deviations (RSD) in the range of 1.0-5.8%. Coefficients of determination R(2)≥0.998 were achieved for each enantiomer in paddy water, rice straw, brown rice and paddy soil matrix calibration curves within the range of 5-500 μg/kg. The limits of quantification (LOQ) for all stereoisomers in the above four matrices were all below 2.0 μg/kg. The methodology was successfully applied for simultaneously enantioselective analysis of flufiprole enantiomers and their chiral metabolite in the real samples, indicating its efficacy in investigating the environmental stereochemistry of flufiprole in paddy field ecosystem. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Small, high-pressure liquid hydrogen turbopump

    NASA Technical Reports Server (NTRS)

    Csomor, A.; Sutton, R.

    1977-01-01

    A high pressure, liquid hydrogen turbopump was designed, fabricated, and tested to a maximum speed of 9739 rad/s and a maximum pump discharge pressure of 2861 N/sq. cm. The approaches used in the analysis and design of the turbopump are described, and fabrication methods are discussed. Data obtained from gas generator tests, turbine performance calibration, and turbopump testing are presented.

  13. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    ERIC Educational Resources Information Center

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  14. The use of denaturing high-pressure liquid chromatography for the detection of mutations in thiopurine methyltransferase.

    PubMed

    Hall, A G; Hamilton, P; Minto, L; Coulthard, S A

    2001-01-30

    The level of expression of the enzyme thiopurine methyltransferase (TPMT) is an important determinant of the metabolism of drugs used both in the treatment of acute leukaemia (6-mercaptopurine and 6-thioguanine) and as an immunosuppressant in patients with autoimmune diseases or following organ transplantation (azathioprine). Studies of enzyme activity in red blood cells have shown that TPMT expression displays genetic polymorphism with 11% of individuals having intermediate and one in 300 undetectable levels. Patients with biallelic mutations and undetectable enzyme activity suffer life-threatening myelosuppression when treated with conventional doses of these drugs. Patients with intermediate activity have an increased risk of drug-associated toxicity. In the Caucasian populations studied to date, intermediate activity is associated with mutations at two sites of the TPMT gene, G460A and A719G (designated TPMT*3A), in 80% of cases. Detection of these mutations has, to date, been based on the analysis of restriction digests of PCR products. In order to simplify this process we have investigated the ability of denaturing high pressure liquid chromatography (DHPLC) to detect the A719G mutation. DHPLC of PCR products from 15 known heterozygotes (TPMT*3A/TPMT*1) and 18 known homozygotes (TPMT*1/TPMT*1) gave a clear pattern difference between the groups and 100% concordance with the results of restriction digests. These results suggest DHPLC represents a valuable technique for accurate and rapid detection of pharmacologically important mutations in the TPMT gene.

  15. Is high pressure liquid chromatography an effective screening tool for characterization of molecular defects in hemoglobinopathies?

    PubMed

    Moorchung, Nikhil; Phillip, Joseph; Sarkar, Ravi Shankar; Prasad, Rupesh; Dutta, Vibha

    2013-01-01

    Hemoglobinopathies constitute entities that are generated by either abnormal hemoglobin or thalassemias. high pressure liquid chromatography (HPLC) is one of the best methods for screening and detection of various hemoglobinopathies but it has intrinsic interpretive problems. The study was designed to evaluate the different mutations seen in cases of hemoglobinopathies and compare the same with screening tests. 68 patients of hemoglobinopathies were screened by HPLC. Mutation studies in the beta globin gene was performed using the polymerase chain reaction (PCR)-based allele-specific Amplification Refractory Mutation System (ARMS). Molecular analysis for the sickle cell mutation was done by standard methods. The IVS 1/5 mutation was the commonest mutation seen and it was seen in 26 (38.23%) of the cases. This was followed by the IVS 1/1, codon 41/42, codon 8/9, del 22 mutation, codon 15 mutation and the -619 bp deletion. No mutation was seen in eight cases. There was a 100% concordance between the sickle cell trait as diagnosed by HPLC and genetic testing. Our study underlies the importance of molecular testing in all cases of hemoglobinopathies. Although HPLC is a useful screening tool, molecular testing is very useful in accurately diagnosing the mutations. Molecular testing is especially applicable in cases with an abnormal hemoglobin (HbD, HbE and HbS) because there may be a concomitant inheritance of a beta thalassemia mutation. Molecular testing is the gold standard when it comes to the diagnosis of hemoglobinopathies.

  16. Quality-by-design-based ultra high performance liquid chromatography related substances method development by establishing the proficient design space for sumatriptan and naproxen combination.

    PubMed

    Patel, Prinesh N; Karakam, Vijaya Saradhi; Samanthula, Gananadhamu; Ragampeta, Srinivas

    2015-10-01

    Quality-by-design-based methods hold greater level of confidence for variations and greater success in method transfer. A quality-by-design-based ultra high performance liquid chromatography method was developed for the simultaneous assay of sumatriptan and naproxen along with their related substances. The first screening was performed by fractional factorial design comprising 44 experiments for reversed-phase stationary phases, pH, and organic modifiers. The results of screening design experiments suggested phenyl hexyl column and acetonitrile were the best combination. The method was further optimized for flow rate, temperature, and gradient time by experimental design of 20 experiments and the knowledge space was generated for effect of variable on response (number of peaks ≥ 1.50 - resolution). Proficient design space was generated from knowledge space by applying Monte Carlo simulation to successfully integrate quantitative robustness metrics during optimization stage itself. The final method provided the robust performance which was verified and validated. Final conditions comprised Waters® Acquity phenyl hexyl column with gradient elution using ammonium acetate (pH 4.12, 0.02 M) buffer and acetonitrile at 0.355 mL/min flow rate and 30°C. The developed method separates all 13 analytes within a 15 min run time with fewer experiments compared to the traditional quality-by-testing approach. ©2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals using ultra-high-performance liquid chromatography-tandem mass spectrometry with the isotope-labelled internal standard method.

    PubMed

    Pan, Xinglu; Dong, Fengshou; Xu, Jun; Liu, Xingang; Chen, Zenglong; Liu, Na; Chen, Xixi; Tao, Yan; Zhang, Hongjun; Zheng, Yongquan

    2015-05-01

    A reliable and sensitive isotope-labelled internal standard method for simultaneous determination of chlorantraniliprole and cyantraniliprole in fruits (apple and grape), vegetables (cucumber and tomato) and cereals (rice and wheat) using ultra-high-performance liquid chromatography-tandem mass spectrometry was developed. Isotope-labelled internal standards were effective in compensating for the loss in the pretreatment and overcoming the matrix effect. The analytes were extracted with acetonitrile and cleaned up with different kinds of sorbents. The determination of the target compounds was achieved in less than 4 min using a T3 column combined with an electrospray ionization source in positive mode. The overall average relative recoveries in all matrices at three spiking levels (10, 20 and 50 μg kg(-1)) ranged from 95.5 to 106.2 %, with all relative standard deviations being less than 14.4 % for all analytes. The limits of detection did not exceed 0.085 μg kg(-1) and the limits of quantification were below 0.28 μg kg(-1) in all matrices. The method was demonstrated to be convenient and accurate for the routine monitoring of chlorantraniliprole and cyantraniliprole in fruits, vegetables and cereals.

  18. Development and validation of rapid multiresidue and multi-class analysis for antibiotics and anthelmintics in feed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Robert, Christelle; Brasseur, Pierre-Yves; Dubois, Michel; Delahaut, Philippe; Gillard, Nathalie

    2016-08-01

    A new multi-residue method for the analysis of veterinary drugs, namely amoxicillin, chlortetracycline, colistins A and B, doxycycline, fenbendazole, flubendazole, ivermectin, lincomycin, oxytetracycline, sulfadiazine, tiamulin, tilmicosin and trimethoprim, was developed and validated for feed. After acidic extraction, the samples were centrifuged, purified by SPE and analysed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. Quantitative validation was done in accordance with the guidelines laid down in European Commission Decision 2002/657/CE. Matrix-matched calibration with internal standards was used to reduce matrix effects. The target level was set at the authorised carryover level (1%) and validation levels were set at 0.5%, 1% and 1.5%. Method performances were evaluated by the following parameters: linearity (0.986 < R(2) < 0.999), precision (repeatability < 12.4% and reproducibility < 14.0%), accuracy (89% < recovery < 107%), sensitivity, decision limit (CCα), detection capability (CCβ), selectivity and expanded measurement uncertainty (k = 2).This method has been used successfully for three years for routine monitoring of antibiotic residues in feeds during which period 20% of samples were found to exceed the 1% authorised carryover limit and were deemed non-compliant.

  19. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    ERIC Educational Resources Information Center

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  20. Phytochemical analysis of Hibiscus caesius using high performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Ain, Quratul; Naveed, Muhammad Na; Mumtaz, Abdul Samad; Farman, Muhammad; Ahmed, Iftikhar; Khalid, Nauman

    2015-09-01

    Various species in genus Hibiscus are traditionally known for their therapeutic attributes. The present study focused on the phytochemical analysis of a rather unexplored species Hibiscus caesius (H. caesius), using high-pressure liquid chromatography coupled with mass spectrometry (HPLC-MS). The analysis revealed five major compounds in the aqueous extract, viz. vanillic acid, protocatechoic acid, quercetin, quercetin glucoside and apigenin, being reported for the first time in H. caesius. Literature suggests that these compounds have important pharmacological traits such as anti-cancer, anti-inflammatory, anti-bacterial and hepatoprotective etc. however, this requires further pharmacological investigations at in vitro and in vivo scale. The above study concluded the medicinal potential of H. caesius.

  1. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    PubMed

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  2. A high-sensitivity ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method for screening synthetic cannabinoids and other drugs of abuse in urine.

    PubMed

    Sundström, Mira; Pelander, Anna; Angerer, Verena; Hutter, Melanie; Kneisel, Stefan; Ojanperä, Ilkka

    2013-10-01

    The continuing emergence of designer drugs imposes high demands on the scope and sensitivity of toxicological drug screening procedures. An ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method was developed for screening and simultaneous confirmation of both designer drugs and other drugs of abuse in urine samples in a single run. The method covered selected synthetic cannabinoids and cathinones, amphetamines, natural cannabinoids, opioids, cocaine and other important drugs of abuse, together with their main urinary metabolites. The database consisted of 277 compounds with molecular formula and exact monoisotopic mass; retention time was included for 192 compounds, and primary and secondary qualifier ion exact mass for 191 and 95 compounds, respectively. Following a solid-phase extraction, separation was performed by UHPLC and mass analysis by HR-TOFMS. MS, and broad-band collision-induced dissociation data were acquired at m/z range 50-700. Compound identification was based on a reverse database search with acceptance criteria for retention time, precursor ion mass accuracy, isotopic pattern and abundance of qualifier ions. Mass resolving power in spiked urine samples was on average FWHM 23,500 and mass accuracy 0.3 mDa. The mean and median cut-off concentrations determined for 75 compounds were 4.2 and 1 ng/mL, respectively. The range of cut-off concentrations for synthetic cannabinoids was 0.2-60 ng/mL and for cathinones 0.7-15 ng/mL. The method proved to combine high sensitivity and a wide scope in a manner not previously reported in drugs of abuse screening. The method's feasibility was demonstrated with 50 authentic urine samples.

  3. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    PubMed

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  4. Systematic chemical profiling of a multicomponent Chinese herbal formula Huo Luo Xiao Ling Dan by ultra high performance liquid chromatography coupled with electrospray ionization quadrupoletime-of-flight mass spectrometry.

    PubMed

    Wang, Fenrong; Ai, Yu; Wu, Yun; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua

    2015-03-01

    Huo Luo Xiao Ling Dan, a Chinese herbal formula consisting of 11 different herbs, has been used in folk medicine for the treatment of arthritis and other chronic inflammatory diseases. However, the chemical compositions of Huo Luo Xiao Ling Dan are not completely characterized. In the present study, an ultra high performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight mass spectrometry method in positive and negative ion modes was employed to identify biochemical constitutes in Huo Luo Xiao Ling Dan. As a result, a total of 76 compounds including alkaloids, monoterpene glycosides, iridoids, phenolic acids, and tanshinones, coumarins, lactones, flavones, and their glycosides, triterpenes, and triterpene saponins were characterized by comparing the retention time and mass spectrometry data with reference standards within 5 ppm error or by reference to the reference literature. These results would provide the basis for a further in vivo study of Huo Luo Xiao Ling Dan and information for potential new drug candidates for treating arthritis and other chronic inflammatory diseases. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Triacylglycerols profiling in plant oils important in food industry, dietetics and cosmetics using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    PubMed

    Lísa, Miroslav; Holcapek, Michal

    2008-07-11

    Optimized non-aqueous reversed-phase high-performance liquid chromatography method using acetonitrile-2-propanol gradient elution and the column coupling in the total length of 45 cm has been applied for the high resolution separation of plant oils important in food industry, dietetics and cosmetics. Positive-ion atmospheric pressure chemical ionization mass spectrometry is used for the unambiguous identification and also the reliable quantitation with the response factors approach. Based on the precise determination of individual triacyglycerol concentrations, the calculation of average parameters important in the nutrition is performed, i.e. average carbon number, average double bond number, relative concentrations of essential, saturated, monounsaturated and polyunsaturated fatty acids. Results are reported in the form of both chromatographic fingerprints and tables containing relative concentrations for all triacylglycerols and fatty acids in individual samples. In total, 264 triacylglycerols consisting of 28 fatty acids with the alkyl chain length from 6 to 26 carbon atoms and 0 to 4 double bonds have been identified in 26 industrial important plant oils.

  6. Multiresidue analysis of endocrine-disrupting compounds and perfluorinated sulfates and carboxylic acids in sediments by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Cavaliere, Chiara; Capriotti, Anna Laura; Ferraris, Francesca; Foglia, Patrizia; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2016-03-18

    A multiresidue analytical method for the determination of 11 perfluorinated compounds and 22 endocrine-disrupting compounds (ECDs) including 13 natural and synthetic estrogens (free and conjugated forms), 2 alkylphenols, 1 plasticiser, 2 UV-filters, 1 antimicrobial, and 2 organophosphorus compounds in sediments has been developed. Ultrasound-assisted extraction followed by solid phase extraction (SPE) with graphitized carbon black (GCB) cartridge as clean-up step were used. The extraction process yield was optimized in terms of solvent composition. Then, a 3(2) experimental design was used to optimize solvent volume and sonication time by response surface methodology, which simplifies the optimization procedure. The final extract was analyzed by ultra-high performance liquid chromatography coupled with tandem mass spectrometry. The optimized sample preparation method is simple and robust, and allows recovery of ECDs belonging to different classes in a complex matrix such as sediment. The use of GCB for SPE allowed to obtain with a single clean-up procedure excellent recoveries ranging between 75 and 110% (relative standard deviation <16%). The developed methodology has been successfully applied to the analysis of ECDs in sediments from different rivers and lakes of the Lazio Region (Italy). These analyses have shown the ubiquitous presence of chloro-substituted organophosphorus flame retardants and bisphenol A, while other analyzed compounds were occasionally found at concentration between the limit of detection and quantification. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Profiling and multivariate statistical analysis of Panax ginseng based on ultra-high-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry.

    PubMed

    Wu, Wei; Sun, Le; Zhang, Zhe; Guo, Yingying; Liu, Shuying

    2015-03-25

    An ultra-high-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry (UHPLC-Q-TOF-MS) method was developed for the detection and structural analysis of ginsenosides in white ginseng and related processed products (red ginseng). Original neutral, malonyl, and chemically transformed ginsenosides were identified in white and red ginseng samples. The aglycone types of ginsenosides were determined by MS/MS as PPD (m/z 459), PPT (m/z 475), C-24, -25 hydrated-PPD or PPT (m/z 477 or m/z 493), and Δ20(21)-or Δ20(22)-dehydrated-PPD or PPT (m/z 441 or m/z 457). Following the structural determination, the UHPLC-Q-TOF-MS-based chemical profiling coupled with multivariate statistical analysis method was applied for global analysis of white and processed ginseng samples. The chemical markers present between the processed products red ginseng and white ginseng could be assigned. Process-mediated chemical changes were recognized as the hydrolysis of ginsenosides with large molecular weight, chemical transformations of ginsenosides, changes in malonyl-ginsenosides, and generation of 20-(R)-ginsenoside enantiomers. The relative contents of compounds classified as PPD, PPT, malonyl, and transformed ginsenosides were calculated based on peak areas in ginseng before and after processing. This study provides possibility to monitor multiple components for the quality control and global evaluation of ginseng products during processing. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Screening of Intestinal Bacterial Metabolites of Platycodin D Using Ultra-Performance Liquid Chromatography/Quadrupole Time-of-Flight Mass Spectrometry.

    PubMed

    Zhang, Wei; Qian, Shi-Hui; Qian, Da-Wei; Li, Song-Lin

    2016-01-01

    Platycodin D (PD), a bioactive triterpenoid saponin isolated from Platycodi Radix (PR), possesses a vast range of biological activities. Although the pharmacological activities and pharmacokinetics of PD have been well demonstrated, information regarding the intestinal metabolisms of PD is very limited. In this study, human and rat fecal microflora were prepared and anaerobically incubated with PD at 37[Formula: see text]C for 48[Formula: see text]h, respectively. A highly sensitive and specific ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MS) was developed for the analysis of PD and related metabolites in the reaction samples. A Liquid-liquid extraction method was used for sample pretreatment and the chromatographic separation was performed on a 1.7 [Formula: see text]m particle size Syncronis C[Formula: see text] column using gradient elution system. Finally, a total of seven metabolites were detected and tentatively identified, such as the demethylation metabolite (M1), deoxidation metabolites (M3, M7) and hydrolysis at the C-28 oligosaccharide metabolites (M5, M6), which were first discovered in this experiment. The results indicate that hydrolysis, demethylation, dehydroxylation, and acetylation were the major metabolic pathways of PDin vitro. Additionally, four bacterial strains from human feces including Enterococcus sp.41, Bacillus sp.46, Escherichia sp.49 A and Escherichia sp.64 were detected and further identified with 16S rRNA gene sequencing due to their relatively strong metabolic capacity toward PD. The present study provides important information about the metabolism of PD, which will help elucidate the impact of intestinal bacteria on this active component.

  9. Identification, characterization, and high-performance liquid chromatography quantification of process-related impurities in vonoprazan fumarate.

    PubMed

    Liu, Lei; Cao, Na; Ma, Xingling; Xiong, Kaihe; Sun, Lili; Zou, Qiaogen

    2016-04-01

    High-performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1-[5-(2-fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high-performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process-related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Association between alterations in global DNA methylation and predisposing factors in diabetes: a high pressure liquid chromatography based study.

    PubMed

    Maghbooli, Z; Hossein-Nezhad, A; Larijani, B; Pasalar, P; Keshtkar, A A

    2015-08-01

    The aim of this study was to investigate the relationship between inter-individual global DNA methylation and diabetes predisposing factors. The 5-methyl cytosine content was assessed by reverse phase high pressure liquid chromatography (RP-HPLC) of peripheral blood leukocytes obtained from 178 type 2 diabetes patients to determine individual global DNA methylation status. There was a positive significant correlation between diabetes duration and DNA methylation levels (P=0.002) with increasing levels of DNA methylation associated with age (P=0.047). There was no significant correlation between DNA methylation levels and HbA1c (P=0.15). No significant differences were observed between patients with and without diabetes predisposing factors including: hypertension (P=0.772), dyslipidemia (P=0.617), insulin resistance (homeostatic model assessment index) (P=0.156) and obesity (P=0.609). As such, the duration of diabetes (>10 years) was the most important predictor of global DNA methylation levels in diabetic patients after adjusting for age and sex (P=0.023). Our findings indicate that chronic hyperglycemic exposure plays an independent role in global DNA methylation levels in type 2 diabetes patients.

  11. A Method for Multiple Mycotoxin Analysis in Wines by Solid Phase Extraction and Multifunctional Cartridge Purification, and Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry

    PubMed Central

    Tamura, Masayoshi; Takahashi, Ayumi; Uyama, Atsuo; Mochizuki, Naoki

    2012-01-01

    An analytical method using two solid phase extractions and ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed for the identification and quantification of 14 mycotoxins (patulin, deoxynivalenol, aflatoxins B1, B2, G1, G2, M1, T-2 toxin, HT-2 toxin, zearalenone, fumonisins B1, B2, B3, and ochratoxin A) in domestic and imported wines. Mycotoxins were purified with an Oasis HLB cartridge, followed by a MultiSepTM #229 Ochra. As a result, sufficient removal of the pigments and highly polar matrices from the red wines was achieved. UHPLC conditions were optimized, and 14 mycotoxins were separated in a total of 13 min. Determinations performed using this method produced high correlation coefficients for the 14 mycotoxins (R > 0.990) and recovery rates ranging from 76 to 105% with good repeatability (relative standard deviation RSD < 12%). Twenty-seven samples of domestic and imported wines were analyzed using this method. Although ochratoxin A (OTA) and fumonisins (FMs) were detected in several samples, the FM levels were less than limits of quantification (LOQs) (1 μg/L), and even the largest of the OTA levels was below the EU regulatory level (2 μg/L). These results suggest that the health risk posed to consumers from the wines available in Japan is relatively low. PMID:22822458

  12. Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Messer, Bradley; Messer, Elisabeth; Sewell, Dale; Sass, Jared; Lott, Jeff; Dutreix, Lionel, III

    2001-01-01

    After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.

  13. Influence of pressure and temperature on molar volume and retention properties of peptides in ultra-high pressure liquid chromatography.

    PubMed

    Fekete, Szabolcs; Horváth, Krisztián; Guillarme, Davy

    2013-10-11

    In this study, pressure induced changes in retention were measured for model peptides possessing molecular weights between ∼1 and ∼4kDa. The goal of the present work was to evaluate if such changes were only attributed to the variation of molar volume and if they could be estimated prior to the experiments, using theoretical models. Restrictor tubing was employed to generate pressures up to 1000bar and experiments were conducted for mobile phase temperatures comprised between 30 and 80°C. As expected, the retention increases significantly with pressure, up to 200% for glucagon at around 1000bar compared to ∼100bar. The obtained data were fitted with a theoretical model and the determination coefficients were excellent (r(2)>0.9992) for the peptides at various temperatures. On the other hand, the pressure induced change in retention was found to be temperature dependent and was more pronounced at 30°C vs. 60 or 80°C. Finally, using the proposed model, it was possible to easily estimate the pressure induced increase in retention for any peptide and mobile phase temperature. This allows to easily estimating the expected change in retention, when increasing the column length under UHPLC conditions. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Expanding the term "Design Space" in high performance liquid chromatography (I).

    PubMed

    Monks, K E; Rieger, H-J; Molnár, I

    2011-12-15

    The current article presents a novel approach to applying Quality by Design (QbD) principles to the development of high pressure reversed phase liquid chromatography (HPLC) methods. Four common critical parameters in HPLC--gradient time, temperature, pH of the aqueous eluent, and stationary phase--are evaluated within the Quality by Design framework by the means of computer modeling software and a column database, to a satisfactory degree. This work proposes the establishment of two mutually complimentary Design Spaces to fully depict a chromatographic method; one Column Design Space (CDS) and one Eluent Design Space (EDS) to describe the influence of the stationary phase and of the mobile phase on the separation selectivity, respectively. The merge of both Design Spaces into one is founded on the continuous nature of the mobile phase influence on retention and the great variety of the stationary phases available. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Rapid resolution liquid chromatography-mass spectrometry and high-performance liquid chromatography-fluorescence detection for metabolism and pharmacokinetic studies of ergosta-4,6,8(14),22-tetraen-3-one.

    PubMed

    Zhao, Ying-Yong; Qin, Xiang-Yang; Cheng, Xian-Long; Liu, Xue-Ying; Lin, Rui-Chao; Zhang, Yongmin; Li, Xiao-Ye; Sun, Xiao-Li; Sun, Wen-Ji

    2010-08-24

    Ergosta-4,6,8(14),22-tetraen-3-one (ergone) from many medicinal plants has been demonstrated to possess a variety of pharmacological activities in vivo and in vitro, including cytotoxic, diuretic and immunosuppressive activity. Metabolism and pharmacokinetic studies on rat were conducted for ergone. Rapid resolution liquid chromatography with atmospheric pressure chemical ionization tandem multi-stage mass spectrometry (RRLC-APCI-MS(n)) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD) methods were applied for the identification and quantification of ergone and its metabolite from rat plasma, faeces and urine. A metabolite was identified by RRLC-DAD-APCI-MS(n): 22,23-epoxy-ergosta-4,6,8(14)-triaen-3-one (epoxyergone). The concentrations of the analyte with its metabolites were determined by HPLC-FLD at excitation wavelength of 370 nm and emission wavelength of 485 nm. The samples were deproteinized with methanol after addition of camptothecin as internal standard (IS). The analysis was performed on a Diamonsil C18 column (150 mm x 4.6 mm x 5 microm) with a mobile phase gradient consisting of methanol and water at a flow rate of 1 mL min(-1). The assay was linear over the concentration range of 42-1500, 36-7500 and 42-1500 ng mL(-1) for plasma, faecal homogenate and urine respectively. The absolute recoveries were found to be 97.0+/-1.2%, 98.1+/-0.7% and 96.6+/-1.8% for plasma, faecal homogenate and urine respectively. The intra-day and inter-day relative standard deviations (RSD) were less than 10%. The previous HPLC-MS/MS method is not affordable for most laboratories because of the specialty requirement and high equipment cost. However, the HPLC-FLD method is economic and operating simply for quantitative determination of ergone and its metabolite in rat plasma, faeces and urine. In addition, liquid chromatography coupled with ion trap multi-stage mass spectrometry is becoming a useful technique for ergone metabolite identification

  16. Determination of rutin and quercetin in Chinese herbal medicine by ionic liquid-based pressurized liquid extraction-liquid chromatography-chemiluminescence detection.

    PubMed

    Wu, Hongwei; Chen, Meilan; Fan, Yunchang; Elsebaei, Fawzi; Zhu, Yan

    2012-01-15

    A novel ionic liquid-based pressurized liquid extraction (IL-PLE) procedure coupled with high performance liquid chromatography (HPLC) tandem chemiluminescence (CL) detection capable of quantifying trace amounts of rutin and quercetin in four Chinese medicine plants including Flos sophorae Immaturus, Crateagus pinnatifida Bunge, Hypericum japonicum Thunb and Folium Mori was described in this paper. To avoid environmental pollution and toxicity to the operators, ionic liquids (ILs), 1-alkyl-3-methylimidazolium chloride ([C(n)mim][Cl]) aqueous solutions were used in the PLE procedure as extractants replacing traditional organic solvents. In addition, chemiluminescence detection was utilized for its minimal interference from endogenous components of complex matrix. Parameters affecting extraction and analysis were carefully optimized. Compared with the conventional ultrasonic-assisted extraction (UAE) and heat-reflux extraction (HRE), the optimized method achieved the highest extraction efficiency in the shortest extraction time with the least solvent consumption. The applicability of the proposed method to real sample was confirmed. Under the optimized conditions, good reproducibility of extraction performance was obtained and good linearity was observed with correlation coefficients (r) between 0.9997 and 0.9999. The detection limits of rutin and quercetin (LOD, S/N=3) were 1.1×10(-2)mg/L and 3.8×10(-3)mg/L, respectively. The average recoveries of rutin and quercetin for real samples were 93.7-105% with relative standard deviation (RSD) lower than 5.7%. To the best of our knowledge, this paper is the first contribution to utilize a combination of IL-PLE with chemiluminescence detection. And the experimental results indicated that the proposed method shows a promising prospect in extraction and determination of rutin and quercetin in medicinal plants. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Ultra high-performance liquid chromatography of porphyrins in clinical materials: column and mobile phase selection and optimisation.

    PubMed

    Benton, Christopher M; Lim, Chang Kee; Moniz, Caje; Jones, Donald J L

    2012-06-01

    Ultra high-performance liquid chromatographic (UHPLC) systems on columns packed with materials ranging from 1.9 to 2.7 µm average particle size were assessed for the fast and sensitive analysis of porphyrins in clinical materials. The fastest separation was achieved on an Agilent Poroshell C(18) column (2.7 µm particle size, 50 × 4.6 mm i.d.), followed by a Thermo Hypersil Gold C(18) column (1.9 µm particle size, 50 × 2.1 mm i.d.) and the Thermo Hypersil BDS C(18) column (2.4 µm particle size, 100 × 2.1 mm i.d.). All columns required a mobile phase containing 1 m ammonium acetate buffer, pH 5.16, with a mixture of acetonitrile and methanol as the organic modifiers for optimum resolution of the type I and III isomers, particularly for uroporphyrin I and III isomers. All UHPLC columns were suitable and superior to conventional HPLC columns packed with 5 µm average particle size materials for clinical sample analysis. Copyright © 2011 John Wiley & Sons, Ltd.

  18. [Determination of 11 industrial antioxidants in the aqueous simulants by ultra-performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Fan, Sai; Zou, Jianhong; Li, Liping; Zhang, Nan; Liu, Wei; Li, Bing; Zhao, Xudong; Wu, Guohua; Xue, Ying; Zhao, Rong

    2014-09-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed to identify and determine 11 industrial antioxidants in the aqueous simulants. A ProElut PLS SPE column was used for the enrichment, and an ACQUITY UPLC BEH C18 UPLC column (100 mm x 2.1 mm, 1.7 μm) was used for separation by the gradient elution with pure water and acetonitrile as the mobile phases. The MS/MS detection was performed with an electrospray ionization (ESI) source in negative mode. The external standard method was used for quantitation in the present study. The linear ranges of the 11 analytes were from 5.0 to 100 μg/L. The coefficients of correlation were greater than 0.995. The recoveries of blank aqueous simulants fortified with the 11 analytes at the levels of 5.0, 10.0 and 20.0 μg/L were 61.4% to 109.4% with the relative standard deviations varied from 3.9% to 18.2% (n = 6). The LODs and LOQs of the 11 analytes in aqueous simulants were 0.2-1.0 μg/L and 0.5-3.0 μg/L, respectively. This method is highly sensitive and accurate, and can be applied to the determination of the 11 trace industrial antioxidants in the aqueous simulants.

  19. Development and validation of an ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method for the simultaneous determination of selected flavonoids in Ginkgo biloba.

    PubMed

    Pandey, Renu; Chandra, Preeti; Arya, Kamal Ram; Kumar, Brijesh

    2014-12-01

    A rapid and sensitive ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous determination of 13 flavonoids in leaf, stem, and fruit extracts of male and female trees of Ginkgo biloba to investigate gender- and age-related variations of flavonoids content. Chromatographic separation was accomplished on an Acquity UPLC BEH C18 column (50 mm × 2.1 mm id, 1.7 μm) in 5 min. Quantitation was performed using negative electrospray ionization mass spectrometry in multiple reaction monitoring mode. The calibration curves of all analytes showed a good linear relationship (r(2) ≥ 0.9977) over the concentration range of 1-1000 ng/mL. The precision evaluated by an intra- and interday study showed RSD ≤ 1.98% and good accuracy with overall recovery in the range from 97.90 to 101.09% (RSD ≤ 1.67%) for all analytes. The method sensitivity expressed as the limit of quantitation was typically 0.25-3.57 ng/mL. The results showed that the total content of 13 flavonoids was higher in the leaf extract of an old male Ginkgo tree compared to young female Ginkgo trees. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. [Analysis of sialic acid in infant formulas using ultra performance liquid chromatography-triple quadrupole mass spectrometry].

    PubMed

    Xie, Honglei; Li, Chun; Liu, Ning

    2013-08-01

    The method for analysing sialic acid in infant formulas by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been established. Sialic acid in milk was released via acid hydrolysis, and purified by an HLB solid phase extraction cartridge. The UPLC separation was performed on an ACQUITY UPLC BEH HILIC column (50 mm x 2.1 mm, 1.7 microm) utilizing a gradient elution program of acetonitrile and water (containing 0.1% formic acid) as the mobile phases at a flow rate of 0.25 mL/min. Injection volume and column temperature were set at 5 microL and 30 degrees C, respectively. The identification and quantification were achieved by using electrospray ionisation (ESI)-MS/MS in positive ion mode and multiple reaction monitoring (MRM) mode. The linear range was from 0.05 to 5.0 mg/L for sialic acid and the correlation coefficient (R(2)) was greater than 0.99. The average recoveries spiked at the four concentration levels of 0.1, 0.5, 2.5 and 5.0 mg/L ranged between 84.3% and 98.9% with the relative standard deviations from 4.9% to 8.2%. The limit of detection was 0.01 mg/L. Therefore, this method has the characteristics of simple operation, high reproducibility and sensitivity. It can be widely applied to determine the total contents of sialic acid in infant formula, cow milk and human milk.

  1. Simultaneous determination of ethyl carbamate and urea in Korean rice wine by ultra-performance liquid chromatography coupled with mass spectrometric detection.

    PubMed

    Lee, Gyeong-Hweon; Bang, Dae-Young; Lim, Jung-Hoon; Yoon, Seok-Min; Yea, Myeong-Jai; Chi, Young-Min

    2017-10-15

    In this study, a rapid method for simultaneous detection of ethyl carbamate (EC) and urea in Korean rice wine was developed. To achieve quantitative analysis of EC and urea, the conditions for Ultra-performance liquid chromatography (UPLC) separation and atmospheric-pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) detection were first optimized. Under the established conditions, the detection limit, relative standard deviation and linear range were 2.83μg/L, 3.75-5.96%, and 0.01-10.0mg/L, respectively, for urea; the corresponding values were 0.17μg/L, 1.06-4.01%, and 1.0-50.0μg/L, respectively, for EC. The correlation between the contents of EC and its precursor urea was determined under specific pH (3.5 and 4.5) and temperature (4, 25, and 50°C) conditions using the developed method. As a result, EC content was increased with greater temperature and lower pH. In Korean rice wine, urea was detected 0.19-1.37mg/L and EC was detected 2.0-7.7μg/L. The method developed in this study, which has the advantages of simplified sample preparation, low detection limits, and good selectivity, was successfully applied for the rapid analysis of EC and urea. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Determination of mycotoxins produced by Fusarium isolates from banana fruits by capillary gas chromatography and high-performance liquid chromatography.

    PubMed

    Jiménez, M; Mateo, R

    1997-08-22

    A method of analysis for trichothecenes (nivalenol, deoxynivalenol, 3- and 15-acetyldeoxynivalenol, diacetoxyscirpenol, neosolaniol, T-2 tetraol, T-2 and HT-2 toxins), zearalenone and zearalenols, and another method for determination of fumonisin B1 are described and applied to cultures of Fusarium isolated from bananas. Both methods were adapted from different techniques of extraction, clean-up and determination of these mycotoxins. The first method involves extraction with methanol-1% aqueous sodium chloride, clean-up of extracts by partition with hexane and dichloromethane, additional solid reversed-phase clean-up and analysis of two eluates by both high-performance liquid chromatography with ultraviolet detection and capillary gas chromatography. The method for fumonisin B1 implies extraction with aqueous methanol, concentration, clean-up with water and methanol on Amberlite XAD-2 column, formation of a fluorescent 4-fluoro-7-nitrobenzofurazan derivative and analysis by high-performance liquid chromatography with fluorescence detection. Both procedures give good limits of detection and recoveries, and are considered suitable for the detection and quantification of the studied toxins in corn and rice cultures of Fusarium spp. isolated from banana fruits.

  3. Stable isotope dilution ultra-high performance liquid chromatography-tandem mass spectrometry quantitative profiling of tryptophan-related neuroactive substances in human serum and cerebrospinal fluid.

    PubMed

    Hényková, Eva; Vránová, Hana Přikrylová; Amakorová, Petra; Pospíšil, Tomáš; Žukauskaitė, Asta; Vlčková, Magdaléna; Urbánek, Lubor; Novák, Ondřej; Mareš, Jan; Kaňovský, Petr; Strnad, Miroslav

    2016-03-11

    Many compounds related to L-tryptophan (L-TRP) have interesting biological or pharmacological activity, and their abnormal neurotransmission seems to be linked to a wide range of neurodegenerative and psychiatric diseases. A high-throughput method based on ultra-high performance liquid chromatography connected to electrospray tandem mass spectrometry (UHPLC-ESI-MS/MS) was developed for the quantitative analysis of L-TRP and 16 of its metabolites in human serum and cerebrospinal fluid (CSF), representing both major and minor routes of L-TRP catabolism. The combination of a fast LC gradient with selective tandem mass spectrometry enabled accurate analysis of almost 100 samples in 24h. The standard isotope dilution method was used for quantitative determination. The method's lower limits of quantification for serum and cerebrospinal fluid ranged from 0.05 to 15nmol/L and 0.3 to 45nmol/L, respectively. Analytical recoveries ranged from 10.4 to 218.1% for serum and 22.1 to 370.0% for CSF. The method's accuracy ranged from 82.4 to 128.5% for serum matrix and 90.7 to 127.7% for CSF matrix. All intra- and inter-day coefficients of variation were below 15%. These results demonstrate that the new method is capable of quantifying endogenous serum and CSF levels of a heterogeneous group of compounds spanning a wide range of concentrations. The method was used to determine the physiological levels of target analytes in serum and CSF samples from 18 individuals, demonstrating its reliability and potential usefulness in large-scale epidemiological studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Comparison of microbial growth inhibition screening assays with high-pressure liquid chromatography for detection of experimentally incurred penicillin G residues in calves.

    PubMed

    Musser, Jeffrey M B; Anderson, Kevin L; Boison, Joe O

    2002-01-01

    Twelve calves were fed milk replacer containing 3.33 ppm penicillin G for one feeding, and 12 calves were fed the medicated milk replacer once daily at a rate of 12% of their body weight for 14 days. Two calves served as controls. Calves were slaughtered 4 to 13 hours after being fed. Kidney, liver, muscle, and urine samples were assayed for penicillin by high-pressure liquid chromatography (HPLC). Penicillin G was not detected in any muscle samples and concentrations of penicillin exceeded the tolerance level (0.05 microg/g) in kidney or liver tissue from 13 of 24 treated-calf carcasses examined by HPLC. The Live Animal Swab Test identified all 13 carcasses with violative drug residues. Using kidney as the test matrix, the Swab Test on Premises identified 10 of 13 carcasses with violative drug residues, while the Calf Antibiotic Sulfa Test identified seven of 13 carcasses with violative residues.

  5. Advanced proteomic liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Fang; Smith, Richard D.; Shen, Yufeng

    2012-10-26

    Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput.

  6. Rapid characterization of chlorogenic acids in Duhaldea nervosa based on ultra-high-performance liquid chromatography-linear trap quadropole-Orbitrap-mass spectrometry and mass spectral trees similarity filter technique.

    PubMed

    Liu, Lianghong; Zhang, Jiayu; Zheng, Binjie; Guan, Ying; Wang, Liting; Chen, Lei; Cai, Wei

    2018-04-01

    Duhaldea nervosa (Wallich ex Candolle) A. Anderberg has been traditionally used as a food spice and also in folk medicine for treating traumatic injury and relieving rheumatism, especially accelerating the healing of a fracture. However, so far as we are aware, the chemical constituents have not been fully investigated. In this study, a practical method of mass spectral trees similarity filter, a data-mining technique, was developed and evaluated for the rapid detection and identification complicated constituents based on ultra-high-performance liquid chromatography-linear trap quadropole-Orbitrap-mass spectrometry. Finally, a total of 47 chlorogenic acids, including 19 monoacyl-quinic acids, 22 diacyl-quinic acids, and six triacyl-quinic acids, were unambiguously or tentatively identified based on their accurate mass measurement, chromatographic retention, MS n spectra, and bibliography data. To our best knowledge, it is the first time to report the chlorogenic acids of D. nervosa, which would be beneficial for the further material basis and quality research. Meanwhile, this mass spectral trees similarity filter method could be envisioned to exhibit a wide application for the identification of complicated components from botanical extracts. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. High Performance Thin Layer Chromatography.

    ERIC Educational Resources Information Center

    Costanzo, Samuel J.

    1984-01-01

    Clarifies where in the scheme of modern chromatography high performance thin layer chromatography (TLC) fits and why in some situations it is a viable alternative to gas and high performance liquid chromatography. New TLC plates, sample applications, plate development, and instrumental techniques are considered. (JN)

  8. Ionic liquid gating on atomic layer deposition passivated GaN: Ultra-high electron density induced high drain current and low contact resistance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Hong; Du, Yuchen; Ye, Peide D., E-mail: yep@purdue.edu

    2016-05-16

    Herein, we report on achieving ultra-high electron density (exceeding 10{sup 14 }cm{sup −2}) in a GaN bulk material device by ionic liquid gating, through the application of atomic layer deposition (ALD) of Al{sub 2}O{sub 3} to passivate the GaN surface. Output characteristics demonstrate a maximum drain current of 1.47 A/mm, the highest reported among all bulk GaN field-effect transistors, with an on/off ratio of 10{sup 5} at room temperature. An ultra-high electron density exceeding 10{sup 14 }cm{sup −2} accumulated at the surface is confirmed via Hall-effect measurement and transfer length measurement. In addition to the ultra-high electron density, we also observe a reductionmore » of the contact resistance due to the narrowing of the Schottky barrier width on the contacts. Taking advantage of the ALD surface passivation and ionic liquid gating technique, this work provides a route to study the field-effect and carrier transport properties of conventional semiconductors in unprecedented ultra-high charge density regions.« less

  9. Ultra high performance liquid chromatography coupled with triple quadrupole mass spectrometry and chemometric analysis of licorice based on the simultaneous determination of saponins and flavonoids.

    PubMed

    Jiang, Zhenzuo; Wang, Yuefei; Zheng, Yunfeng; Yang, Jing; Zhang, Lei

    2016-08-01

    Licorice is among the most popular herbal medicines and frequently used in traditional medicine, food products, and cosmetics. In China, only Glycyrrhiza uralensis Fisch., Glycyrrhiza inflata Bat. and Glycyrrhiza glabra L. are officially used and are usually processed with honey prior to use. To maintain the quality of commercially available herbal products, a simple, rapid, and reliable ultra high performance liquid chromatography with triple quadrupole mass spectrometry was developed to investigate the major active constituents of commercially available licorice products. Nineteen components were accurately determined, including eight triterpenoid saponins, one triterpene, and ten flavonoids. Subsequently, multivariate statistical analysis methods were employed to further explore and interpret the experimental data. The results indicated that liquiritin apioside may be considered as a candidate index for the quality control of licorice as well as 18β-glycyrrhizic acid and liquiritin. In addition, both 18β-glycyrrhizic acid and licorice-saponin G2 can be used for discrimination between crude and honey-processed licorice. Furthermore, using 18β-glycyrrhizic acid and liquiritin as markers, this work revealed that the quality of licorice products may have declined in recent years. This highlights the need for additional effort focused on good agricultural practice during the processing of licorice. In summary, this study provides a valuable reference for the quality assessment of licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Free amino acids, biogenic amines, and ammonium profiling in tobacco from different geographical origins using microwave-assisted extraction followed by ultra high performance liquid chromatography.

    PubMed

    Cai, Kai; Xiang, Zhangmin; Li, Hongqin; Zhao, Huina; Lin, Yechun; Pan, Wenjie; Lei, Bo

    2017-12-01

    This work describes a rapid, stable, and accurate method for determining the free amino acids, biogenic amines, and ammonium in tobacco. The target analytes were extracted with microwave-assisted extraction and then derivatized with diethyl ethoxymethylenemalonate, followed by ultra high performance liquid chromatography analysis. The experimental design used to optimize the microwave-assisted extraction conditions showed that the optimal extraction time was 10 min with a temperature of 60°C. The stability of aminoenone derivatives was improved by keeping the pH near 9.0, and there was no obvious degradation during the 80°C heating and room temperature storage. Under optimal conditions, this method showed good linearity (R 2 > 0.999) and sensitivity (limits of detection 0.010-0.081 μg/mL). The extraction recoveries were between 88.4 and 106.5%, while the repeatability and reproducibility ranged from 0.48 to 5.12% and from 1.56 to 6.52%, respectively. The newly developed method was employed to analyze the tobacco from different geographical origins. Principal component analysis showed that four geographical origins of tobacco could be clearly distinguished and that each had their characteristic components. The proposed method also showed great potential for further investigations on nitrogen metabolism in plants. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Determination of glucosinolates in rapeseed and Thlaspi caerulescens plants by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    PubMed

    Tolrà, R P; Alonso, R; Poschenrieder, C; Barceló, D; Barceló, J

    2000-08-11

    Liquid chromatography-atmospheric pressure chemical ionization mass spectrometry was used to identify glucosinolates in plant extracts. Optimization of the analytical conditions and the determination of the method detection limit was performed using commercial 2-propenylglucosinolate (sinigrin). Optimal values for the following parameters were determined: nebulization pressure, gas temperature, flux of drying gas, capillar voltage, corona current and fragmentor conditions. The method detection limit for sinigrin was 2.85 ng. For validation of the method the glucosinolates in reference material (rapeseed) from the Community Bureau of Reference Materials (BCR) were analyzed. The method was applied for the determination of glucosinolates in Thlaspi caerulescens plants.

  12. Chemical investigation of saponins in different parts of Panax notoginseng by pressurized liquid extraction and liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Wan, Jian-Bo; Zhang, Qing-Wen; Hong, Si-Jia; Li, Peng; Li, Shao-Ping; Wang, Yi-Tao

    2012-05-16

    A pressurized liquid extraction (PLE) and high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method was developed for the qualitative determination of saponins in different parts of P. notoginseng, including rhizome, root, fibre root, seed, stem, leaf and flower. The samples were extracted using PLE. The analysis was achieved on a Zorbax SB-C18 column with gradient elution of acetonitrile and 8 mM aqueous ammonium acetate as mobile phase. The mass spectrometer was operated in the negative ion mode using the electrospray ionization, and a collision induced dissociation (CID) experiment was also carried out to aid the identification of compounds. Forty one saponins were identified in different parts of P. notoginseng according to the fragmentation patterns and literature reports, among them, 21 saponins were confirmed by comparing the retention time and ESI-MS data with those of standard compounds. The results showed that the chemical characteristics were obviously diverse in different parts of P. notoginseng, which is helpful for pharmacological evaluation and quality control of P. notoginseng.

  13. Quantitative analysis of phylloquinone (vitamin K1) in soy bean oils by high-performance liquid chromatography.

    PubMed

    Zonta, F; Stancher, B

    1985-07-19

    A high-performance liquid chromatographic method for determining phylloquinone (vitamin K1) in soy bean oils is described. Resolution of vitamin K1 from interfering peaks of the matrix was obtained after enzymatic digestion, extraction and liquid-solid chromatography on alumina. An isocratic reversed-phase chromatography with UV detection was used in the final stage. The quantitation was carried out by the standard addition method, and the recovery of the whole procedure was 88.2%.

  14. Improved sample treatment for the determination of 17 strong sorbed quinolone antibiotics from compost by ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Dorival-García, N; Labajo-Recio, C; Zafra-Gómez, A; Juárez-Jiménez, B; Vílchez, J L

    2015-06-01

    The use of compost from sewage sludge for agricultural application is nowadays increasing, since composting is recognized as one of the most important recycling options for this material, being a source of nutrients for plants but also of contamination by persistent pollutants. In the present work, a multi-residue analytical method for the determination of 17 quinolone antibiotic residues in compost using multivariate optimization strategies and ultra high performance liquid chromatography-tandem mass spectrometry has been developed. It is based on the use of microwave-assisted extraction at drastic conditions with ACN:m-phosphoric acid (1% w/v) for 5 min at 120°C, in order to achieve a quantitative extraction of the compounds (>76% of extraction recovery). Extracts were cleaned-up by salt-assisted liquid-liquid extraction (SALLE) with NaCl at pH 1.5 (with HClO4) and then using a dispersive sorbent (PSA). After LC separation, the MS conditions, in positive electrospray ionization mode (ESI), were individually optimized for each analyte to obtain maximum sensitivity in the selected reaction monitoring mode (SRM). The analytes were separated in less than 7 min. Cincophen was used as surrogate standard. The limits of detection ranged from 0.2 to 0.5 ng g(-1), and the limits of the quantification from 0.5 to 1.5 ng g(-1), while intra- and inter-day variability (% RSD) was under 7% in all cases. A recovery assay was performed with spiked samples. Recoveries ranging from 95.3% to 106.2% were obtained. Cleanup procedure reduced significantly matrix effects, which constitutes an important achievement, considering the important drawbacks of matrix components in quality and validation parameters. This method was applied to several commercial compost samples. Only 6 of the studied antibiotics were not detected in any of the samples. The antibiotics with the highest concentrations were ciprofloxacin (836 ng g(-1)), ofloxacin (719 ng g(-1)), and enrofloxacin (674 ng g(-1

  15. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    PubMed

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  16. Quantitative analysis of benzodiazepines in vitreous humor by high-performance liquid chromatography

    PubMed Central

    Bazmi, Elham; Behnoush, Behnam; Akhgari, Maryam; Bahmanabadi, Leila

    2016-01-01

    Objective: Benzodiazepines are frequently screened drugs in emergency toxicology, drugs of abuse testing, and in forensic cases. As the variations of benzodiazepines concentrations in biological samples during bleeding, postmortem changes, and redistribution could be biasing forensic medicine examinations, hence selecting a suitable sample and a validated accurate method is essential for the quantitative analysis of these main drug categories. The aim of this study was to develop a valid method for the determination of four benzodiazepines (flurazepam, lorazepam, alprazolam, and diazepam) in vitreous humor using liquid–liquid extraction and high-performance liquid chromatography. Methods: Sample preparation was carried out using liquid–liquid extraction with n-hexane: ethyl acetate and subsequent detection by high-performance liquid chromatography method coupled to diode array detector. This method was applied to quantify benzodiazepines in 21 authentic vitreous humor samples. Linear curve for each drug was obtained within the range of 30–3000 ng/mL with coefficient of correlation higher than 0.99. Results: The limit of detection and quantitation were 30 and 100 ng/mL respectively for four drugs. The method showed an appropriate intra- and inter-day precision (coefficient of variation < 10%). Benzodiazepines recoveries were estimated to be over 80%. The method showed high selectivity; no additional peak due to interfering substances in samples was observed. Conclusion: The present method was selective, sensitive, accurate, and precise for the quantitative analysis of benzodiazepines in vitreous humor samples in forensic toxicology laboratory. PMID:27635251

  17. Advanced proteomic liquid chromatography

    PubMed Central

    Xie, Fang; Smith, Richard D.; Shen, Yufeng

    2012-01-01

    Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput. PMID:22840822

  18. Highly compressible fluorescent particles for pressure sensing in liquids

    NASA Astrophysics Data System (ADS)

    Cellini, F.; Peterson, S. D.; Porfiri, M.

    2017-05-01

    Pressure sensing in liquids is important for engineering applications ranging from industrial processing to naval architecture. Here, we propose a pressure sensor based on highly compressible polydimethylsiloxane foam particles embedding fluorescent Nile Red molecules. The particles display pressure sensitivities as low as 0.0018 kPa-1, which are on the same order of magnitude of sensitivities reported in commercial pressure-sensitive paints for air flows. We envision the application of the proposed sensor in particle image velocimetry toward an improved understanding of flow kinetics in liquids.

  19. Quantitative analysis of flavonoids, alkaloids and saponins of Banxia Xiexin decoction using ultra-high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Ying; Xu, Ranchi; Xiao, Juan; Zhang, Jian; Wang, Xinhong; An, Rui; Ma, Yueming

    2014-01-01

    Banxia Xiexin decoction (BXD) is an effective Chinese Medicinal Prescription in treating gastroenteritis diseases. In this study an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to separate and determine 18 major active ingredients of BXD in order to guarantee quality. The separation of ten flavonoids, four alkaloids and four saponins was accomplished on an Acquity BEH C18 (2.1mm×100mm, 1.7μm) column using gradient elution with 0.1% (v/v) formic acid water (A) and 0.1% (v/v) formic acid in methanol (B). All the analytes were detected in positive electrospray ionization tandem mass spectrometry by selective reaction monitoring (SRM) mode. A good linear regression relationship for each analyte was obtained over the range from 2.41-438ng/ml to 20.75-4150ng/ml. The precision was evaluated by intra- and inter-day assays with relative standard deviation (RSD) less than 7.7%. The recovery measured at three concentration levels varied from 92.4% to 107.8%. The method sensitivity expressed as LOQ was typically 0.97-4.15ng/ml. The assay was successfully applied for determination of the 18 bioactive compounds in BXD. The results indicated that the new UPLC-MS/MS method was rapid and accurate, and could be reliably utilized as a quality control method for BXD. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Metabolomics method based on ultra high performance liquid chromatography with time-of-flight mass spectrometry to analyze toxins in fresh and dried toad venom.

    PubMed

    Ma, Hongyue; Niu, Huixia; Cao, Qin; Zhou, Jing; Gong, Yan; Zhu, Zhenhua; Lv, Xiang; Di, Liuqing; Qian, Dawei; Wu, Qinan; Duan, Jin'ao

    2016-12-01

    Drying is a critical step to prolong the storage time in natural medicine processing but it changes the chemical characteristics of the product. In this study, research was performed to characterize the metabolomic changes in toad venom induced by vacuum-drying at 60°C and air-drying at room temperature by ultra high performance liquid chromatography coupled with pattern recognition approaches. In total 52 metabolites, down-regulated or up-regulated, were identified as potential chemical markers. Compared with fresh toad venom, vacuum-drying at 60°C succeeded in raising the conjugated-type bufadienolide content significantly, while the content of free-type bufadienolides were slightly reduced. On the other hand, toad venom air-dried at room temperature presented a relatively low amount of bufadienolides compared with fresh venom. For example, the content of several known anti-tumor components (gamabufotalin, bufotalin, cinobufagin, etc.) were significantly reduced. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide bioassay further showed that venom air-dried at room temperature had weaker anti-tumor activity on human hepatocellular carcinoma SMMC-7721 proliferation in vitro than samples vacuum-dried at 60°C. These results showed that the great metabolomic changes of toad venom occurred during the drying process, suggesting that a proper drying procedure is important for sustaining the chemical quality of natural medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.