Sample records for ultraminiature proportional counter

  1. Proportional counter radiation camera

    DOEpatents

    Borkowski, C.J.; Kopp, M.K.

    1974-01-15

    A gas-filled proportional counter camera that images photon emitting sources is described. A two-dimensional, positionsensitive proportional multiwire counter is provided as the detector. The counter consists of a high- voltage anode screen sandwiched between orthogonally disposed planar arrays of multiple parallel strung, resistively coupled cathode wires. Two terminals from each of the cathode arrays are connected to separate timing circuitry to obtain separate X and Y coordinate signal values from pulse shape measurements to define the position of an event within the counter arrays which may be recorded by various means for data display. The counter is further provided with a linear drift field which effectively enlarges the active gas volume of the counter and constrains the recoil electrons produced from ionizing radiation entering the counter to drift perpendicularly toward the planar detection arrays. A collimator is interposed between a subject to be imaged and the counter to transmit only the radiation from the subject which has a perpendicular trajectory with respect to the planar cathode arrays of the detector. (Official Gazette)

  2. Monitor proportional counter

    NASA Technical Reports Server (NTRS)

    Weisskopf, M. C.

    1979-01-01

    An Uhuru class Ar-CO2 gas filled proportional counter sealed with a 1.5 mil beryllium window and sensitive to X-rays in the energy bandwidth from 1.5 to 22 keV is presented. This device is coaligned with the X-ray telescope aboard the Einstein Observatory and takes data as a normal part of the Observatory operations.

  3. Multistep fluorescence gated proportional counters

    NASA Technical Reports Server (NTRS)

    Ramsey, Brian D.; Weisskopf, Martin C.

    1990-01-01

    A proportional counter is introduced in which the levels of energy and spatial resolutions and background rejection permit the application of the device to X-ray astronomy. A multistep approach is employed in which photons cause a signal that triggers the system and measures the energy of the incident photon. The multistep approach permits good energy resolution from parallel geometry and from the imaging stage due to coupling of the imaging and amplification stages. The design also employs fluorescence gating to reduce background, a method that is compatible with the multistep technique. Use of the proportional counter is reported for NASA's supernova campaign, and the pair background is below 0.0001 counts/sq cm sec keV at the xenon k-edge. Potential improvements and applications are listed including the CASES, POF, and EXOSS mission programs.

  4. Shielding concepts for low-background proportional counter arrays in surface laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Humble, Paul H.; Mace, Emily K.

    2016-02-01

    Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily and activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportionalmore » counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37Ar.« less

  5. The MSFC large-area imaging multistep proportional counter

    NASA Technical Reports Server (NTRS)

    Ramsey, B. D.; Weisskopf, M. C.; Joy, M. K.

    1989-01-01

    A large-area multistep imaging proportional counter that is being currently developed at the Marshall Space Flight Center is described. The device, known as a multistep fluorescence gated detector, consists of a multiwire proportional counter (MWPC) with a preamplification region. The MWCP features superior spatial resolution with a very high degree of background rejection. It is ideally suited for use in X-ray astronomy in 20-100 keV energy range. The paper includes the MWPC schematic and a list of instrument specifications.

  6. Multianode cylindrical proportional counter for high count rates

    DOEpatents

    Hanson, J.A.; Kopp, M.K.

    1980-05-23

    A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (< 60 keV) at count rates of greater than 10/sup 5/ counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.

  7. Multianode cylindrical proportional counter for high count rates

    DOEpatents

    Hanson, James A.; Kopp, Manfred K.

    1981-01-01

    A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (<60 keV) at count rates of greater than 10.sup.5 counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.

  8. GAMMA PROPORTIONAL COUNTER CONTAINING HIGH Z GAS AND LOW Z MODERATOR

    DOEpatents

    Fox, R.

    1963-07-23

    A gamma radiation counter employing a gas proportional counter is described. The radiation counter comprises a cylindrical gas proportional counter which contains a high atomic number gas and is surrounded by a low atomic number gamma radiation moderator material. At least one slit is provided in the moderator to allow accident gamma radiation to enter the moderator in the most favorable manner for moderation, and also to allow low energy gamma radiation to enter the counter without the necessity of passing through the moderator. This radiation counter is capable of detecting and measuring gamma radiation in the energy range of 0.5-5 Mev. (AEC)

  9. Characteristics of a high pressure gas proportional counter filled with xenon

    NASA Technical Reports Server (NTRS)

    Sakurai, H.; Ramsey, B. D.

    1991-01-01

    The characteristics of a conventional cylindrical geometry proportional counter filled with high pressure xenon gas up to 10 atm. were fundamentally investigated for use as a detector in hard X-ray astronomy. With a 2 percent methane gas mixture the energy resolutions at 10 atm. were 9.8 percent and 7.3 percent for 22 keV and 60 keV X-rays, respectively. From calculations of the Townsend ionization coefficient, it is shown that proportional counters at high pressure operate at weaker reduced electric field than low pressure counters. The characteristics of a parallel grid proportional counter at low pressure showed similar pressure dependence. It is suggested that this is the fundamental reason for the degradation of resolution observed with increasing pressure.

  10. Proportional Counter Calibration and Analysis for 12C + p Resonance Scattering

    NASA Astrophysics Data System (ADS)

    Nelson, Austin; Rogachev, Grigory; Uberseder, Ethan; Hooker, Josh; Koshchiy, Yevgen

    2014-09-01

    Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A < 16). Experimental information on the structure of light exotic nuclei is crucial to determine the validity of these calculations and to fix the parameters for the three-nucleon forces. Resonance scattering with rare isotope beams is a very effective tool to study spectroscopy of nuclei near the drip line. A new setup was developed at the Cyclotron Institute for effective resonance scattering measurements. The setup includes ionization chamber, silicon array, and an array of proportional counters. The proportional counter array, consisting of 8 anode wires arranged in a parallel cellular grid, is used for particle identification and to track the positioning of light recoils. The main objective of this project was to test the performance and perform position calibration of this proportional counter array. The test was done using 12C beam. The excitation function for 12C + p elastic scattering was measured and calibration of the proportional counter was performed using known resonances in 13N. The method of calibration, including solid angle calculations, normalization corrections, and position calibration will be presented. Light exotic nuclei provide a unique opportunity to test the predictions of modern ab initio theoretical calculations near the drip line. In ab initio approaches, nuclear structure is described starting from bare nucleon-nucleon and three-nucleon interactions. Calculations are very heavy and can only be performed for the lightest nuclei (A < 16). Experimental information on the structure of light exotic nuclei is crucial to determine the validity of these calculations and to fix the parameters for the three

  11. Ultraminiature broadband light source with spiral shaped filament

    NASA Technical Reports Server (NTRS)

    McConaghy, Charles F. (Inventor); Olsen, Barry L. (Inventor); Tuma, Margaret L. (Inventor); Collura, Joseph S. (Inventor); Pocha, Michael D. (Inventor); Helvajian, Henry (Inventor); Meyer, Glenn A. (Inventor); Hansen, William W (Inventor)

    2012-01-01

    An ultraminiature light source using a double-spiral shaped tungsten filament includes end contact portions which are separated to allow for radial and length-wise unwinding of the spiral. The double-spiral filament is spaced relatively far apart at the end portions thereof so that contact between portions of the filament upon expansion is avoided. The light source is made by fabricating a double-spiral ultraminiature tungsten filament from tungsten foil and housing the filament in a ceramic package having a reflective bottom and a well wherein the filament is suspended. A vacuum furnace brazing process attaches the filament to contacts of the ceramic package. Finally, a cover with a transparent window is attached onto the top of the ceramic package by solder reflow in a second vacuum furnace process to form a complete hermetically sealed package.

  12. Position-sensitive proportional counter with low-resistance metal-wire anode

    DOEpatents

    Kopp, Manfred K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which allows the use of a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counter. A pair of specially designed active-capacitance preamplifiers are used to terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, low-noise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates (>10.sup.6 counts/sec).

  13. Multiplexing readout channels in proportional counters

    NASA Technical Reports Server (NTRS)

    Caristi, James

    1991-01-01

    Proportional counters are important instruments used in sensing hard x-rays. The possibility is described of doubling the number of readout channels in the detector without increasing the electronics needed to amplify channel signals. This suggests that it should be possible, conversely, to reduce the number of amplifiers, thereby reducing the weight and energy budget of the instrument. Various numerical multiplexing schemes are analyzed, and a computer program is presented that can reconstruct multiplexed channel outputs with very good accuracy.

  14. Air Proportional Counter

    DOEpatents

    Simpson, Jr, J A

    1950-12-05

    A multiple wire counter utilizing air at atmospheric pressure as the ionizing medium and having a window of a nylon sheet of less than 0.5 mil thickness coated with graphite. The window is permeable to alpha particles so that the counter is well adapted to surveying sources of alpha radiation.

  15. Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol

    NASA Astrophysics Data System (ADS)

    Amaro, F. D.; Monteiro, C. M. B.; Dos Santos, J. M. F.; Antognini, A.

    2017-02-01

    The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the illicit transport of nuclear material, of which neutron detectors are key components. 3He is very rare and during the last decade this gas has become increasingly difficult to acquire. With the exception of BF3, which is toxic, no other gas can be used for neutron detection in proportional counters. We present an alternative where the 3He atoms are replaced by nanoparticles made of another neutron sensitive material, 10B. The particles are dispersed in a gaseous volume, forming an aerosol with neutron sensitive properties. A proportional counter filled with such aerosol was exposed to a thermal neutron beam and the recorded response indicates that the neutrons have interacted with the particles in the aerosol. This original technique, which transforms a standard proportional gas mixture into a neutron sensitive aerosol, is a breakthrough in the field of radiation detection and has the potential to become an alternative to the use of 3He in proportional counters.

  16. Ultraminiature Broadband Light Source and Method of Manufacturing Same

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L. (Inventor); Collura, Joseph S. (Inventor); Helvajian, Henry (Inventor); Pocha, Michael D. (Inventor); Meyer, Glenn A. (Inventor); McConaghy, Charles F. (Inventor); Olsen, Barry L. (Inventor); Hansen, William W. (Inventor)

    2010-01-01

    An ultraminiature light source using a double-spiral shaped tungsten filament includes end contact portions which are separated to allow for radial and length-wise unwinding of the spiral. The double-spiral filament is spaced relatively far apart at the end portions thereof so that contact between portions of the filament upon expansion is avoided. The light ource is made by fabricating a double-spiral ultraminiature tungsten filament from tungsten foil and housing the filament in a ceramic package having a reflective bottom and a well wherein the filament is suspended. A vacuum furnace brazing process attaches the filament to contacts of the ceramic package. Finally, a cover with a transparent window is attached onto the top of the ceramic package by solder reflow in a second vacuum furnace process to form a complete hermetically sealed package.

  17. X-ray astronomy instrumentation studies. [design of a proportional counter and measurements of fluorescent radiation

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1981-01-01

    Preliminary designs were made for a multiplane, multiwire position sensitive proportional counter for X-ray use. Anode spacing was 2 mm and cathode spacing 1 mm. Assistance was provided in setting up and operating two multiwire proportional counters, one with 5 mm anode spacing, and the other with 2 mm spacing. Argon-based counter gases were used for preliminary work in assembling a working experimental system to measure xenon fluorescence yields. The design and specification of a high purity gas filling system capable of supplying mixtures of xenon and other gases to proportional counters was also performed. The system is mounted on a cart, is fully operational, and is flexible enough to be easily used as a pumping station for other clean applications. When needed, assistance was given to put into operation various computer-related pieces of equipment.

  18. Response of a tissue equivalent proportional counter to neutrons

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Robbins, D. E.; Gibbons, F.; Braby, L. A.

    2002-01-01

    The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

  19. Calibration methodology for proportional counters applied to yield measurements of a neutron burst.

    PubMed

    Tarifeño-Saldivia, Ariel; Mayer, Roberto E; Pavez, Cristian; Soto, Leopoldo

    2014-01-01

    This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

  20. Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

    NASA Technical Reports Server (NTRS)

    Lheureux, J.; Fan, C. Y.; Mainardi, R.; Gloeckler, G.

    1974-01-01

    A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

  1. Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

    NASA Technical Reports Server (NTRS)

    Lheureux, J.; Fan, C. Y.; Gloeckler, G.; Mainardi, R.

    1973-01-01

    A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

  2. A multiball read-out for the spherical proportional counter

    NASA Astrophysics Data System (ADS)

    Giganon, A.; Giomataris, I.; Gros, M.; Katsioulas, I.; Navick, X. F.; Tsiledakis, G.; Savvidis, I.; Dastgheibi-Fard, A.; Brossard, A.

    2017-12-01

    We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high-pressure operations. We have developed a multi-ball read-out system which consists of several balls placed at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case, the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.

  3. A complete database for the Einstein imaging proportional counter

    NASA Technical Reports Server (NTRS)

    Helfand, David J.

    1991-01-01

    A complete database for the Einstein Imaging Proportional Counter (IPC) was completed. The original data that makes up the archive is described as well as the structure of the database, the Op-Ed analysis system, the technical advances achieved relative to the analysis of (IPC) data, the data products produced, and some uses to which the database has been put by scientists outside Columbia University over the past year.

  4. Initial Characterization of Unequal-Length, Low-Background Proportional Counters for Absolute Gas-Counting Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Emily K.; Aalseth, Craig E.; Bonicalzi, Ricco

    Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates,more » gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.« less

  5. Initial characterization of unequal-length, low-background proportional counters for absolute gas-counting applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, E. K.; Aalseth, C. E.; Bonicalzi, R.

    Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., {sup 37}Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counter designs and now operate in PNNL's shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of Oxygen-Free High-Conductivity copper components for use in a shielded above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of backgroundmore » rates, gas gain, and energy resolution. These results will be presented along with a shielding study for the above-ground cave.« less

  6. A sealed titanium window proportional counter for the detection of .5-keV X rays.

    NASA Technical Reports Server (NTRS)

    Mcclintock, J. E.; Levine, A.; Rappaport, S.

    1972-01-01

    A sealed Ti window proportional counter sensitive to X radiation in the energy range 0.35-0.45 keV and above 1.5 keV is described. Measurements of the Ti mass absorption coefficients and a graphical summary of the literature values are presented. For a proportional counter with a 930 microgram/sq cm (2.1-micron) Ti window, the peak efficiency at 0.45 keV is found to lie between 4.6% and 7.1%. An application in X-ray astronomy involving a rocket observation of Sco X-1 is discussed.

  7. Background in X-ray astronomy proportional counters

    NASA Technical Reports Server (NTRS)

    Bower, C. R.; Dietz, K. L.; Ramsey, B. D.; Weisskopf, M. C.

    1991-01-01

    The authors report the results of an investigation into the nature of background events in proportional counters sensitive to X-ray photons having energy of less than 150 keV. Even with the use of thick shields composed of high-atomic-number material, a significant flux background in the detector's energy region can result from multiple Compton scattering in the mass surrounding the active region of the detector. The importance of the selection of detector components in the reduction of the background by more than an order of magnitude is emphasized. Experimental results are shown to agree qualitatively with Monte Carlo simulations. It is concluded that escape gating is a powerful means of determining the nature of background in flight detectors: the single/pair ratios reveal whether the detected events are charged particles or photons.

  8. High-efficiency and low-background multi-segmented proportional gas counter for β-decay spectroscopy

    NASA Astrophysics Data System (ADS)

    Mukai, M.; Hirayama, Y.; Watanabe, Y. X.; Schury, P.; Jung, H. S.; Ahmed, M.; Haba, H.; Ishiyama, H.; Jeong, S. C.; Kakiguchi, Y.; Kimura, S.; Moon, J. Y.; Oyaizu, M.; Ozawa, A.; Park, J. H.; Ueno, H.; Wada, M.; Miyatake, H.

    2018-03-01

    A multi-segmented proportional gas counter (MSPGC) with high detection efficiency and low-background event rate has been developed for β-decay spectroscopy. The MSPGC consists of two cylindrically aligned layers of 16 counters (32 counters in total). Each counter has a long active length and small trapezoidal cross-section, and the total solid angle of the 32 counters is 80% of 4 π. β-rays are distinguished from the background events including cosmic-rays by analyzing the hit patterns of independent counters. The deduced intrinsic detection efficiency of each counter was almost 100%. The measured background event rate was 0.11 counts per second using the combination of veto counters for cosmic-rays and lead block shields for background γ-rays. The MSPGC was applied to measure the β-decay half-lives of 198Ir and 199mPt. The evaluated half-lives of T1/2 = 9 . 8(7) s and 12.4(7) s for 198Ir and 199mPt, respectively, were in agreement with previously reported values. The estimated absolute detection efficiency of the MSPGC from GEANT4 simulations was consistent with the evaluated efficiency from the analysis of the β- γ spectroscopy of 199Pt, saturating at approximately 60% for Qβ > 4 MeV.

  9. The background in a balloon-borne fluorescence-gated proportional counter

    NASA Technical Reports Server (NTRS)

    Ramsey, B. D.; Bower, C. R.; Dietz, K. L.; Weisskopf, M. C.

    1990-01-01

    The results of an analysis of the background in a fluorescence-gated proportional counter operating over the energy range 3-150 keV are presented. It is found that the dominant background component is that produced by high energy qamma-rays that penetrate the shields and undergo multiple scattering in the detector body, resulting in photoelectric absorption in the detector gas. A careful choice of materials and thickness can move the peak of this emission outside of the detector sensitive range, thereby dramatically reducing the residual background.

  10. Soft X-ray astronomy proportional counter electronics

    NASA Technical Reports Server (NTRS)

    Gardner, W. R.

    1971-01-01

    The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

  11. Design and performance of A 3He-free coincidence counter based on parallel plate boron-lined proportional technology

    DOE PAGES

    Henzlova, D.; Menlove, H. O.; Marlow, J. B.

    2015-07-01

    Thermal neutron counters utilized and developed for deployment as non-destructive assay (NDA) instruments in the field of nuclear safeguards traditionally rely on 3He-based proportional counting systems. 3He-based proportional counters have provided core NDA detection capabilities for several decades and have proven to be extremely reliable with range of features highly desirable for nuclear facility deployment. Facing the current depletion of 3He gas supply and the continuing uncertainty of options for future resupply, a search for detection technologies that could provide feasible short-term alternative to 3He gas was initiated worldwide. As part of this effort, Los Alamos National Laboratory (LANL) designedmore » and built a 3He-free full scale thermal neutron coincidence counter based on boron-lined proportional technology. The boronlined technology was selected in a comprehensive inter-comparison exercise based on its favorable performance against safeguards specific parameters. This paper provides an overview of the design and initial performance evaluation of the prototype High Level Neutron counter – Boron (HLNB). The initial results suggest that current HLNB design is capable to provide ~80% performance of a selected reference 3He-based coincidence counter (High Level Neutron Coincidence Counter, HLNCC). Similar samples are expected to be measurable in both systems, however, slightly longer measurement times may be anticipated for large samples in HLNB. The initial evaluation helped to identify potential for further performance improvements via additional tailoring of boron-layer thickness.« less

  12. Special-geometry proportional counters and techniques for detection of low-levels of X-rays and beta-particles

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1976-01-01

    The use and sensitivity of the multiwire proportional counter to detect Kr-85 in ambient air are examined. Data also cover monitoring beta and X-ray emitting radio nuclides at low activity levels. Results show the counter to have excellent properties for monitoring Kr-85 down to 0.0004 pCi cu/cm.

  13. Lineal energy calibration of mini tissue-equivalent gas-proportional counters (TEPC)

    NASA Astrophysics Data System (ADS)

    Conte, V.; Moro, D.; Grosswendt, B.; Colautti, P.

    2013-07-01

    Mini TEPCs are cylindrical gas proportional counters of 1 mm or less of sensitive volume diameter. The lineal energy calibration of these tiny counters can be performed with an external gamma-ray source. However, to do that, first a method to get a simple and precise spectral mark has to be found and then the keV/μm value of this mark. A precise method (less than 1% of uncertainty) to identify this markis described here, and the lineal energy value of this mark has been measured for different simulated site sizes by using a 137Cs gamma source and a cylindrical TEPC equipped with a precision internal 244Cm alpha-particle source, and filled with propane-based tissue-equivalent gas mixture. Mini TEPCs can be calibrated in terms of lineal energy, by exposing them to 137Cesium sources, with an overall uncertainty of about 5%.

  14. A High-Energy Focal-Plane Gas Scintillation Proportional Counter

    NASA Technical Reports Server (NTRS)

    Ramsey, B. D.; Austin, R. A.; Apple, J. A.; Dietz, K. L.

    1999-01-01

    We have developed a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a hard-x-ray telescope. It features an absorption region 50 mm in diameter and 50 mm deep, filled with Xenon + 4% He at 10(exp 6) Pa total pressure, which gives useful response (greater than 75% efficiency) up to the mirror cut-off of 70 keV. Tests with a prototype unit show an energy resolution of 3.5% at 60 keV and a spatial resolution of 0.35 mm from 30-50 keV. Two flight units are currently under construction for a balloon flight in September 1999. Full details of their design and performance will be presented together with available quick-look background data from the flight.

  15. Demand-type gas supply system for rocket borne thin-window proportional counters

    NASA Technical Reports Server (NTRS)

    Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.

    1977-01-01

    A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

  16. Simulations of electron avalanches in an ultra-low-background proportional counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, John W.; Aalseth, Craig; Dion, Michael P.

    2016-02-01

    New classes have been added to the simulation package Garfield++ to import the potential and electric field solutions generated by ANSYS R MaxwellTM v.16. Using these tools we report results on the simulation of electron avalanches and induced signal waveforms in comparison to experimental data of the ultra-lowbackground gas proportional counters being developed at Pacific Northwest National Laboratory. Furthermore, an improved mesh search algorithm based on Delaunay triangulation was implemented and provided at least a three order of magnitude time savings when compared to the built-in point-location search class of Garfield++.

  17. On studies of 3He and isobutane mixture as neutron proportional counter gas

    NASA Astrophysics Data System (ADS)

    Desai, S. S.; Shaikh, A. M.

    2006-02-01

    The performance of neutron detectors filled with 3He+iC 4H 10 (isobutane) gas mixtures has been studied and compared with the performance of detectors filled with 3He+Kr gas mixtures. The investigations are made to determine suitable concentration of isobutane in the gas mixture to design neutron proportional counters and linear position sensitive neutron detectors (1-D PSDs). Energy resolution, range of proportionality, plateau and gas gain characteristics are studied for various gas mixtures of 3He and isobutane. The values for various gas constants are determined by fitting the gas gains to Diethorn and Bateman's equations and their variation with isobutane concentration in the fill gas mixture is studied.

  18. Magnetic monopole search by 130 m(2)sr He gas proportional counter

    NASA Technical Reports Server (NTRS)

    Hara, T.; Hayashida, N.; Honda, M.; Kamata, K.; Kobayashi, M.; Kondo, T.; Matsubara, Y.; Mori, M.; Ohno, Y.; Tanahashi, G.

    1985-01-01

    A search experiment for cosmic ray magnetic monopoles was performed by means of atomic induction mechanism by using He mixture gas proportional counters of the calorimeter (130 square meters sr) at the center of the Akeno air shower array. In 3,482 hours operation no monopole candidate was observed. The upper limit of the monopole flux is 1.44 x 10 to the minus 13th power cm-z, sec -1, sr-1 (90% C.L.) for the velocity faster than 7 x 0.0001 c.

  19. Evaluation of a High Pressure Proportional Counter for the Detection of Radioactive Noble Gases

    DTIC Science & Technology

    1987-01-01

    Multiplication Curves Compared to Reconstructed Literature Curves .. .. ............ .81 6.4 Resolution .... . .. ......................... .... 90 v Figure...with 57 ~/57 energy resolution to 12% fwhm for Co photopeaks (-122 keV),sing argon fill gas at fifty atmospheres. Subsequent effects 0f a contami- nant...internal gas proportional counters for measuring low-level environmental radionuclides, resolutions to 27% fwhm and intrinsic efficiencies to 3 75

  20. Ultra-miniaturization of a planar amperometric sensor targeting continuous intradermal glucose monitoring.

    PubMed

    Ribet, Federico; Stemme, Göran; Roxhed, Niclas

    2017-04-15

    An ultra-miniaturized electrochemical biosensor for continuous glucose monitoring (CGM) is presented. The aim of this work is to demonstrate the possibility of an overall reduction in sensor size to allow minimally invasive glucose monitoring in the interstitial fluid in the dermal region, in contrast to larger state-of-the-art systems, which are necessarily placed in the subcutaneous layer. Moreover, the reduction in size might be a key factor to improve the stability and reliability of transdermal sensors, due to the reduction of the detrimental foreign body reaction and of consequent potential failures. These advantages are combined with lower invasiveness and discomfort for patients. The realized device consists of a microfabricated three-electrode enzymatic sensor with a total surface area of the sensing portion of less than 0.04mm 2 , making it the smallest fully integrated planar amperometric glucose sensor area reported to date. The working electrode and counter electrode consist of platinum and are functionalized by drop casting of three polymeric membranes. The on-chip iridium oxide (IrOx) pseudo-reference electrode provides the required stability for measurements under physiological conditions. The device is able to dynamically and linearly measure glucose concentrations in-vitro over the relevant physiological range, while showing sufficient selectivity to known interfering species present in the interstitial fluid, with resolution and sensitivity (1.51nA/mM) comparable to that of state-of-art commercial CGM systems. This work can therefore enable less invasive and improved CGM in patients affected by diabetes. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources

    NASA Technical Reports Server (NTRS)

    Hamilton, T. T.; Hailey, C. J.; Ku, W. H.-M.; Novick, R.

    1980-01-01

    In recent years much effort has been devoted to the development of large area gas scintillation proportional counters (GSPCs) suitable for use in X-ray astronomy. The paper deals with a low-energy GSPC for use in detecting sub-keV X-rays from cosmic sources. This instrument has a measured energy resolution of 85 eV (FWHM) at 149 eV over a sensitive area of 5 sq cm. The development of imaging capability for this instrument is discussed. Tests are performed on the feasibility of using an arrangement of several phototubes placed adjacent to one another to determine event locations in a large flat counter. A simple prototype has been constructed and successfully operated.

  2. Low energy recoil detection with a spherical proportional counter

    NASA Astrophysics Data System (ADS)

    Savvidis, I.; Katsioulas, I.; Eleftheriadis, C.; Giomataris, I.; Papaevangellou, T.

    2018-01-01

    We present results for the detection of low energy nuclear recoils in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An 241Am-9Be fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the keV energy region was measured by observing the 5.9 keV line of a 55Fe X-ray source, with energy resolution of 10% (σ). The toolkit GEANT4 was used to simulate the irradiation of the detector by an 241Am-9Be source, while SRIM was used to calculate the Ionization Quenching Factor (IQF), the simulation results are compared with the measurements. The potential of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering).

  3. Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ramsey, Brian; Apple, Jeffery

    2003-01-01

    A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

  4. Performance of large area x-ray proportional counters in a balloon experiment

    NASA Astrophysics Data System (ADS)

    Roy, J.; Agrawal, P. C.; Dedhia, D. K.; Manchanda, R. K.; Shah, P. B.; Chitnis, V. R.; Gujar, V. M.; Parmar, J. V.; Pawar, D. M.; Kurhade, V. B.

    2016-10-01

    ASTROSAT is India's first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3 ∘ × 3 ∘ versus FOV of 1 ∘ × 1 ∘ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for ˜ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.

  5. A technique for searching for the 2 K capture in 124Xe with a copper proportional counter

    NASA Astrophysics Data System (ADS)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-12-01

    An experimental technique for searching for the 2 K capture in 124Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 107 relative to that at the Earth's surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of 124Xe with respect to the 2 K capture is set at the level of 2.5 × 1021 years.

  6. Four pi-recoil proportional counter used as neutron spectrometer

    NASA Technical Reports Server (NTRS)

    Bennett, E. F.

    1968-01-01

    Study considers problems encountered in using 4 pi-recoil counters for neutron spectra measurement. Emphasis is placed on calibration, shape discrimination, variation of W, the average energy loss per ion pair, and the effects of differentiation on the intrinsic counter resolution.

  7. A Complete Public Archive for the Einstein Imaging Proportional Counter

    NASA Technical Reports Server (NTRS)

    Helfand, David J.

    1996-01-01

    Consistent with our proposal to the Astrophysics Data Program in 1992, we have completed the design, construction, documentation, and distribution of a flexible and complete archive of the data collected by the Einstein Imaging Proportional Counter. Along with software and data delivered to the High Energy Astrophysics Science Archive Research Center at Goddard Space Flight Center, we have compiled and, where appropriate, published catalogs of point sources, soft sources, hard sources, extended sources, and transient flares detected in the database along with extensive analyses of the instrument's backgrounds and other anomalies. We include in this document a brief summary of the archive's functionality, a description of the scientific catalogs and other results, a bibliography of publications supported in whole or in part under this contract, and a list of personnel whose pre- and post-doctoral education consisted in part in participation in this project.

  8. Ultra-miniature wireless temperature sensor for thermal medicine applications

    PubMed Central

    Khairi, Ahmad; Hung, Shih-Chang; Paramesh, Jeyanandh; Fedder, Gary; Rabin, Yoed

    2017-01-01

    This study presents a prototype design of an ultra-miniature, wireless, battery-less, and implantable temperature-sensor, with applications to thermal medicine such as cryosurgery, hyperthermia, and thermal ablation. The design aims at a sensory device smaller than 1.5 mm in diameter and 3 mm in length, to enable minimally invasive deployment through a hypodermic needle. While the new device may be used for local temperature monitoring, simultaneous data collection from an array of such sensors can be used to reconstruct the 3D temperature field in the treated area, offering a unique capability in thermal medicine. The new sensory device consists of three major subsystems: a temperature-sensing core, a wireless data-communication unit, and a wireless power reception and management unit. Power is delivered wirelessly to the implant from an external source using an inductive link. To meet size requirements while enhancing reliability and minimizing cost, the implant is fully integrated in a regular foundry CMOS technology (0.15 μm in the current study), including the implant-side inductor of the power link. A temperature-sensing core that consists of a proportional-to-absolute-temperature (PTAT) circuit has been designed and characterized. It employs a microwatt chopper stabilized op-amp and dynamic element-matched current sources to achieve high absolute accuracy. A second order sigma-delta (Σ-Δ) analog-to-digital converter (ADC) is designed to convert the temperature reading to a digital code, which is transmitted by backscatter through the same antenna used for receiving power. A high-efficiency multi-stage differential CMOS rectifier has been designed to provide a DC supply to the sensing and communication subsystems. This paper focuses on the development of the all-CMOS temperature sensing core circuitry part of the device, and briefly reviews the wireless power delivery and communication subsystems. PMID:28989222

  9. Ultra-miniature wireless temperature sensor for thermal medicine applications.

    PubMed

    Khairi, Ahmad; Hung, Shih-Chang; Paramesh, Jeyanandh; Fedder, Gary; Rabin, Yoed

    2011-01-01

    This study presents a prototype design of an ultra-miniature, wireless, battery-less, and implantable temperature-sensor, with applications to thermal medicine such as cryosurgery, hyperthermia, and thermal ablation. The design aims at a sensory device smaller than 1.5 mm in diameter and 3 mm in length, to enable minimally invasive deployment through a hypodermic needle. While the new device may be used for local temperature monitoring, simultaneous data collection from an array of such sensors can be used to reconstruct the 3D temperature field in the treated area, offering a unique capability in thermal medicine. The new sensory device consists of three major subsystems: a temperature-sensing core, a wireless data-communication unit, and a wireless power reception and management unit. Power is delivered wirelessly to the implant from an external source using an inductive link. To meet size requirements while enhancing reliability and minimizing cost, the implant is fully integrated in a regular foundry CMOS technology (0.15 μm in the current study), including the implant-side inductor of the power link. A temperature-sensing core that consists of a proportional-to-absolute-temperature (PTAT) circuit has been designed and characterized. It employs a microwatt chopper stabilized op-amp and dynamic element-matched current sources to achieve high absolute accuracy. A second order sigma-delta (Σ-Δ) analog-to-digital converter (ADC) is designed to convert the temperature reading to a digital code, which is transmitted by backscatter through the same antenna used for receiving power. A high-efficiency multi-stage differential CMOS rectifier has been designed to provide a DC supply to the sensing and communication subsystems. This paper focuses on the development of the all-CMOS temperature sensing core circuitry part of the device, and briefly reviews the wireless power delivery and communication subsystems.

  10. Compact multiwire proportional counters for the detection of fission fragments

    NASA Astrophysics Data System (ADS)

    Jhingan, Akhil; Sugathan, P.; Golda, K. S.; Singh, R. P.; Varughese, T.; Singh, Hardev; Behera, B. R.; Mandal, S. K.

    2009-12-01

    Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20×10 cm2 and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

  11. Development of a Nanomaterial Anode for a Low-Voltage Proportional Counter for Neutron Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craps, Matthew Greg

    NanoTechLabs (NTL) in collaboration with the Savannah River National Laboratory (SRNL) and Clemson University have continued development of a next generation proportional counter (PC) for neutron detection utilizing robust, inexpensive nanostructured anodes while maximizing neutron capture. Neutron detectors are vital to national security as they can be used to detect illicit trafficking of radioactive materials, which could mean the presence of or planning of a dirty bomb attack. Typical PCs operate with high bias potentials that create electronic noise. Incorporating nanomaterials into the anode of PCs can theoretically operate at low voltages (eg. 10-300V) due to an increase in themore » electric field associated with a smaller diameter nano-scale anode. In addition to the lower operating voltage, typical high PC voltages (500-1200V) could be used to generate a larger electric field resulting in more electrons being collected, thus increasing the sensitivity of the PC. Other advantages of nano-PC include reduced platform size, weight, cost, and improved ruggedness. Clemson modeled the electric field around the CNT array tips. NTL grew many ordered CNT arrays as well as control samples and densified the arrays to improve the performance. The primary objective for this work is to provide evidence of a commercially viable technique for reducing the voltage of a parallel plate proportional counter using nanosized anodes. The parallel plate geometry has advantages over the typical cylindrical design based on more feasible placement of solid neutron absorbers and more geometrically practical windows for radiation capture and directional detection.« less

  12. A suspended boron foil multi-wire proportional counter neutron detector

    NASA Astrophysics Data System (ADS)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-01

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 μm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the 10B(n,α)7Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal-neutron detection efficiency for enriched 10B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  13. Experimental results from an X-ray imaging crystal spectrometer utilizing multi-wire proportional counter for KSTAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S. G., E-mail: sglee@nfri.re.kr; Kim, Y. S.; Yoo, J. W.

    2016-11-15

    The inconsistency of the first experimental results from the X-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research device utilizing a multi-wire proportional counter (MWPC) is clarified after improving the photon-count rate of the data acquisition system for the MWPC and ground loop isolator for the whole spectrometer system. The improved MWPC is successfully applied to pure Ohmic plasmas as well as plasmas with high confinement modes.

  14. Scalable High-Performance Ultraminiature Graphene Micro-Supercapacitors by a Hybrid Technique Combining Direct Writing and Controllable Microdroplet Transfer.

    PubMed

    Shen, Daozhi; Zou, Guisheng; Liu, Lei; Zhao, Wenzheng; Wu, Aiping; Duley, Walter W; Zhou, Y Norman

    2018-02-14

    Miniaturization of energy storage devices can significantly decrease the overall size of electronic systems. However, this miniaturization is limited by the reduction of electrode dimensions and the reproducible transfer of small electrolyte drops. This paper reports first a simple scalable direct writing method for the production of ultraminiature microsupercapacitor (MSC) electrodes, based on femtosecond laser reduced graphene oxide (fsrGO) interlaced pads. These pads, separated by 2 μm spacing, are 100 μm long and 8 μm wide. A second stage involves the accurate transfer of an electrolyte microdroplet on top of each individual electrode, which can avoid any interference of the electrolyte with other electronic components. Abundant in-plane mesopores in fsrGO induced by a fs laser together with ultrashort interelectrode spacing enables MSCs to exhibit a high specific capacitance (6.3 mF cm -2 and 105 F cm -3 ) and ∼100% retention after 1000 cycles. An all graphene resistor-capacitor (RC) filter is also constructed by combining the MSC and a fsrGO resistor, which is confirmed to exhibit highly enhanced performance characteristics. This new hybrid technique combining fs laser direct writing and precise microdroplet transfer easily enables scalable production of ultraminiature MSCs, which is believed to be significant for practical application of micro-supercapacitor microelectronic systems.

  15. First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Emily K.; Aalseth, Craig E.; Day, Anthony R.

    Abstract Simultaneous measurement of tritium and 14C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960’s atmospheric tritium and 14C have fallen dramatically as the isotopic injections from above-ground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and 14C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for smallmore » samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and 14C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. The dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). For samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.« less

  16. Study of microdosimetric energy deposition patterns in tissue-equivalent medium due to low-energy neutron fields using a graphite-walled proportional counter.

    PubMed

    Waker, A J; Aslam

    2011-06-01

    To improve radiation protection dosimetry for low-energy neutron fields encountered in nuclear power reactor environments, there is increasing interest in modeling neutron energy deposition in metrological instruments such as tissue-equivalent proportional counters (TEPCs). Along with these computational developments, there is also a need for experimental data with which to benchmark and test the results obtained from the modeling methods developed. The experimental work described in this paper is a study of the energy deposition in tissue-equivalent (TE) medium using an in-house built graphite-walled proportional counter (GPC) filled with TE gas. The GPC is a simple model of a standard TEPC because the response of the counter at these energies is almost entirely due to the neutron interactions in the sensitive volume of the counter. Energy deposition in tissue spheres of diameter 1, 2, 4 and 8 µm was measured in low-energy neutron fields below 500 keV. We have observed a continuously increasing trend in microdosimetric averages with an increase in neutron energy. The values of these averages decrease as we increase the simulated diameter at a given neutron energy. A similar trend for these microdosimetric averages has been observed for standard TEPCs and the Rossi-type, TE, spherical wall-less counter filled with propane-based TE gas in the same energy range. This implies that at the microdosimetric level, in the neutron energy range we employed in this study, the pattern of average energy deposited by starter and insider proton recoil events in the gas is similar to those generated cumulatively by crosser and stopper events originating from the counter wall plus starter and insider recoil events originating in the sensitive volume of a TEPC.

  17. Dual-Chamber/Dual-Anode Proportional Counter Incorporating an Intervening Thin-Foil Solid Neutron Converter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boatner, Lynn A; Neal, John S; Blackston, Matthew A

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6LiF or 10B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected rather than having half of the products absorbed in the wall of a conventional tube type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimummore » neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6LiF converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6LiF and 10B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.« less

  18. MCNP modelling of the wall effects observed in tissue-equivalent proportional counters.

    PubMed

    Hoff, J L; Townsend, L W

    2002-01-01

    Tissue-equivalent proportional counters (TEPCs) utilise tissue-equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Density differences between the two materials cause distortions, or wall effects, in measurements, with the most dominant effect caused by delta rays. This study uses a Monte Carlo transport code, MCNP, to simulate the transport of secondary electrons within a TEPC. The Rudd model, a singly differential cross section with no dependence on electron direction, is used to describe the energy spectrum obtained by the impact of two iron beams on water. Based on the models used in this study, a wall-less TEPC had a higher lineal energy (keV.micron-1) as a function of impact parameter than a solid-wall TEPC for the iron beams under consideration. An important conclusion of this study is that MCNP has the ability to model the wall effects observed in TEPCs.

  19. Neutron spectrum measurements using proton recoil proportional counters: results of measurements of leakage spectra for the Little Boy assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, E.F.; Yule, T.J.

    1984-01-01

    Measurements of degraded fission-neutron spectra using recoil proportional counters are done routinely for studies involving fast reactor mockups. The same techniques are applicable to measurements of neutron spectra required for personnel dosimetry in fast neutron environments. A brief discussion of current applications of these methods together with the results of a measurement made on the LITTLE BOY assembly at Los Alamos are here described.

  20. Thin-window high-efficiency position sensitive proportional counter for the vacuum flat crystal spectrometers on the Lawrence Livermore National Laboratory electron beam ion trap (abstract)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, G. V.; Beiersdorfer, P.; Goddard, R.

    2001-01-01

    We have mounted 1 {mu}m thick aluminized polyimide windows onto the position sensitive proportional counters employed by the wide-band flat crystal spectrometers at the Lawrence Livermore National Laboratory electron beam ion trap experiment. The aluminized polyimide, supported by thin wires across the short axis of the window, is used to isolate the detection chamber of the proportional counters, which operate at a pressure of 760 Torr, from the vacuum chamber of the spectrometer. The windows are modified versions of those developed for the proportional counters which were used during ground calibration of the Chandra X-ray Observatory. The transmission properties ofmore » these windows are, therefore, well known. The increased transmission efficiency of the polyimide windows relative to the 4 {mu}m thick polypropylene window material previously employed by our proportional counters has extended the useful range of the spectrometer from roughly 20 to 30 Aa at energies below the carbon edge, as well as increasing detection efficiency at wavelengths beyond the carbon edge. Using an octadecyl hydrogen maleate crystal with 2d=63.5Aa, we demonstrate the increased wavelength coverage by measuring the resonance, intercombination, and forbidden lines in helium-like NVII in two different density regimes. The thin polyimide windows have also increased the efficiency of the spectrometers entire wavelength range. To demonstrate the increased efficiency we compare the FeXVII spectrum in the 15--17 Aa band measured with the 1 {mu}m aluminized polyimide windows to the 4 {mu}m aluminized polypropylene windows. The comparison shows an average increase in efficiency of {approx}40%. The polyimide windows have a significantly lower leak rate than the polypropylene windows making it possible to achieve approximately an order of magnitude lower pressure in the spectrometer vacuum chamber which reduces the gas load on the trap region.« less

  1. High-Sensitivity X-ray Polarimetry with Amorphous Silicon Active-Matrix Pixel Proportional Counters

    NASA Technical Reports Server (NTRS)

    Black, J. K.; Deines-Jones, P.; Jahoda, K.; Ready, S. E.; Street, R. A.

    2003-01-01

    Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout

  2. Performance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy

    NASA Technical Reports Server (NTRS)

    Dietz, K. L.; Ramsey, B. D.; Weisskopf, M. C.

    1992-01-01

    Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.

  3. Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Ramsey, Brian; Apple, Jeffery

    2004-01-01

    A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

  4. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions.

    PubMed

    Straume, T; Braby, L A; Borak, T B; Lusby, T; Warner, D W; Perez-Nunez, D

    2015-10-01

    Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of yD (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with g rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h(-1). Measurements of yD for 200 MeV n(-1) carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%.

  5. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions

    PubMed Central

    Straume, T.; Braby, L.A.; Borak, T.B.; Lusby, T.; Warner, D.W.; Perez-Nunez, D.

    2015-01-01

    Abstract Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with γ rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h−1. Measurements of for 200 MeV n−1 carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%. PMID:26313585

  6. Review of the Microdosimetric Studies for High-Energy Charged Particle Beams Using a Tissue-Equivalent Proportional Counter

    NASA Astrophysics Data System (ADS)

    Tsuda, Shuichi; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Sasaki, Shinichi

    Lineal energy (y) distributions were measured for various types of charged particles such as protons and iron, with kinetic energies of up to 500 MeV/u, via the use of a wall-less tissue-equivalent proportional counter (TEPC). Radial dependencies of y distributions were also experimentally evaluated to investigate the track structures of protons, carbon, and iron beams. This paper reviews a series of measured data using the aforementioned TEPC as well as assesses the systematic verification of a microdosimetric calculation model of a y distribution incorporated into the particle and heavy ion transport code system (PHITS) and associated track structure models.

  7. Low-level gamma and neutron monitoring based on use of proportional counter filled with 3He in polythene moderator: study of the responses to gamma and neutrons.

    PubMed

    Pszona, S; Bantsar, A; Tulik, P; Wincel, K; Zaręba, B

    2014-10-01

    It has been shown that a proportional counter filled with (3)He placed centrally inside a polythene sphere opens a new possibility for measuring gamma photons and neutrons in the separate pulse-height windows. The responses to gamma and neutrons (in terms of ambient dose equivalent) of the detector assembly consisting of 203-mm polythene sphere with centrally positioned 40-mm diameter (3)He proportional counter have been studied. The response to secondary gammas from capture process in hydrogen has also been studied. The rather preliminary studies indicate that the proposed measuring system has very promising features as an ambient dose equivalent device for mixed gamma-neutron fields. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Radiation Counters

    DOEpatents

    Simpson, Jr, J A

    1950-01-31

    Geiger-Mueller and proportional counters operating at low potentials (about 125-300 v) obtained by utilizing certain ratios of diameters of the electrodes and particular mixtures of noble gases as the ionizing medium are covered in this application.

  9. Calibration of the Large Area X-Ray Proportional Counter (LAXPC) Instrument on board AstroSat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antia, H. M.; Yadav, J. S.; Chauhan, Jai Verdhan

    We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on board AstroSat . The LAXPC instrument has three nominally identical detectors to achieve a large collecting area. These detectors are independent of each other, and in the event analysis mode they record the arrival time and energy of each photon that is detected. The detectors have a time resolution of 10 μ s and a dead-time of about 42 μ s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel-to-energy mapping were obtained from calibration on the ground usingmore » radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab after launch. At around 20 keV the energy resolution of the detectors is 10%–15%, while the combined effective area of the three detectors is about 6000 cm{sup 2}.« less

  10. Calibration of an Ultra-Low-Background Proportional Counter for Measuring 37Ar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seifert, Allen; Aalseth, Craig E.; Bonicalzi, Ricco

    Abstract. An ultra-low-background proportional counter (ULBPC) design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electrochemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) constructed at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with 14C/3H, age-dating of groundwater with 39Ar, and soil-gas assay for 37Ar to support On-Site Inspection (OSI). On-Site Inspection is a key componentmore » of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of 37Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of 37Ar samples over a broad range of pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for 37Ar soil gas background studies.« less

  11. Advances in the RXTE Proportional Counter Array Calibration: Nearing the Statistical Limit

    NASA Technical Reports Server (NTRS)

    Shaposhnikov, Nikolai; Jahoda, Keith; Markwardt, Craig; Swank, Jean; Strohmayer, Tod

    2012-01-01

    During its 16 years of service Rossi X-ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observation of variable X-ray sources for fast timing studies. It is, therefore, very important to have the most reliable calibration of RXTE instruments. The Proportional Counter Array (PCA) is the primary instrument on-board RXTE which provides data in 2-50 keY with higher than millisecond time resolution in up to 256 energy channels. In 2009 RXTE team revised the response residual minimization method used to derive the parameters of the PCA physical model. The procedure is now based on the residual minimization between the model spectrum for Crab nebula emission and a calibration data set consisting of a number of spectra from the Crab and the on-board Am241 calibration source, uniformly covering a whole RXTE span. The new method led to a much more effective model convergence and allowed for better understanding of the behavior of the PCA energy-to-channel relationship. It greatly improved the response matrix performance. We describe the new version of the RXTE/PCA response generator PCARMF vll.7 along with the corresponding energy-to-channel conversion table (version e05v04) and their difference from the previous releases of PCA calibration. The new PCA response adequately represents the spectrum of the calibration sources and successfully predicts the energy of the narrow iron emission line in Cas-A throughout the RXTE mission.

  12. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    PubMed

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  13. Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Emily K.; Aalseth, Craig E.; Bonicalzi, Ricco

    2013-05-01

    ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequentmore » testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.« less

  14. RADIATION COUNTER

    DOEpatents

    Goldsworthy, W.W.

    1958-02-01

    This patent relates to a radiation counter, and more particularly, to a scintillation counter having high uniform sensitivity over a wide area and capable of measuring alpha, beta, and gamma contamination over wide energy ranges, for use in quickly checking the contami-nation of personnel. Several photomultiplier tubes are disposed in parallel relationship with a light tight housing behind a wall of scintillation material. Mounted within the housing with the photomultipliers are circuit means for producing an audible sound for each pulse detected, and a range selector developing a voltage proportional to the repetition rate of the detected pulses and automatically altering its time constant when the voltage reaches a predetermined value, so that manual range adjustment of associated metering means is not required.

  15. Use of propane as a quench gas in argon-filled proportional counters and comparison with other quench gases

    NASA Technical Reports Server (NTRS)

    Agrawal, P. C.; Ramsey, B. D.

    1988-01-01

    An experimental investigation of propane and six other quench gases was carried out in argon-filled proportional counters. The objective of the study was to find the best gas mixture for optimizing the gas gain and the energy resolution as well as to understand the role of the ionization potential of quench gases in determining these parameters. It was found that the best gas gains and energy resolutions are obtained with propane, ethane, and isobutane in that order. The ionization potentials of these three lie below the argon metastable potentials and have the lowest value of resonance defect compared to the other quench gases. The better results obtained with these mixtures can be explained by an increased ionization yield resulting from the Penning effect. Propylene and trans-2-butene give inferior performance compared to the above three gases. Methane and carbon dioxide, the most commonly used quench gases in the argon-filled detectors, provide the worst results.

  16. Neutron counter based on beryllium activation

    NASA Astrophysics Data System (ADS)

    Bienkowska, B.; Prokopowicz, R.; Scholz, M.; Kaczmarczyk, J.; Igielski, A.; Karpinski, L.; Paducha, M.; Pytel, K.

    2014-08-01

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction 9Be(n, α)6He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, 6He, decays with half-life T1/2 = 0.807 s emitting β- particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β-particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β-source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5-the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β- particles emitted from radioactive 6He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

  17. HILT - A heavy ion large area proportional counter telescope for solar and anomalous cosmic rays

    NASA Technical Reports Server (NTRS)

    Klecker, Berndt; Hovestadt, Dietrich; Scholer, M.; Arbinger, H.; Ertl, M.; Kaestle, H.; Kuenneth, E.; Laeverenz, P.; Seidenschwang, E.; Blake, J. B.

    1993-01-01

    The HILT sensor has been designed to measure heavy ion elemental abundances, energy spectra, and direction of incidence in the mass range from He to Fe and in the energy range 4 to 250 MeV/nucleon. With its large geometric factor of 60 sq cm sr the sensor is optimized to provide compositional and spectral measurements for low intensity cosmic rays (i.e. for small solar energetic particle events and for the anomalous component of cosmic rays). The instrument combines a large area ion drift chamber-proportional counter system with two arrays of 16 Li-drift solid state detectors and 16 CsI crystals. The multi dE/dx-E technique provides a low background mass and energy determination. The sensor also measures particle direction. Combining these measurements with the information on the spacecraft position and attitude in the low-altitude polar orbit, it will be possible to infer the ionic charge of the ions from the local cutoff of the Earth's magnetic field. The ionic charge in this energy range is of particular interest because it provides unique clues to the origin of these particles and has not been investigated systematically so far. Together with the other instruments on board SAMPEX (LEICA, MAST, and PET), a comprehensive measurement of the entire solar and anomalous particle population will be achieved.

  18. Einstein Observatory SSS and MPC observations of the complex X-ray spectra of Seyfert galaxies. [Solid State Spectrometer and Monitor Proportional Counter

    NASA Technical Reports Server (NTRS)

    Turner, T. J.; Weaver, K. A.; Mushotzky, R. F.; Holt, S. S.; Madejski, G. M.

    1991-01-01

    The X-ray spectra of 25 Seyfert galaxies measured with the Solid State Spectrometer on the Einstein Observatory have been investigated. This new investigation utilizes simultaneous data from the Monitor Proportional Counter, and automatic correction for systematic effects in the Solid State Spectrometer which were previously handled subjectively. It is found that the best-fit single-power-law indices generally agree with those previously reported, but that soft excesses of some form are inferred for about 48 percent of the sources. One possible explanation of the soft excess emission is a blend of soft X-ray lines, centered around 0.8 keV. The implications of these results for accretion disk models are discussed.

  19. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting.

    PubMed

    Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen

    2017-08-01

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120mg of H 2 O and present sensitivity results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting

    DOE PAGES

    Mace, Emily; Aalseth, Craig; Alexander, Tom; ...

    2016-12-21

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. In this paper, we present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H 2O and present sensitivity results.

  1. Characterization of a CMOS sensing core for ultra-miniature wireless implantable temperature sensors with application to cryomedicine.

    PubMed

    Khairi, Ahmad; Thaokar, Chandrajit; Fedder, Gary; Paramesh, Jeyanandh; Rabin, Yoed

    2014-09-01

    In effort to improve thermal control in minimally invasive cryosurgery, the concept of a miniature, wireless, implantable sensing unit has been developed recently. The sensing unit integrates a wireless power delivery mechanism, wireless communication means, and a sensing core-the subject matter of the current study. The current study presents a CMOS ultra-miniature PTAT temperature sensing core and focuses on design principles, fabrication of a proof-of-concept, and characterization in a cryogenic environment. For this purpose, a 100 μm × 400 μm sensing core prototype has been fabricated using a 130 nm CMOS process. The senor has shown to operate between -180°C and room temperature, to consume power of less than 1 μW, and to have an uncertainty range of 1.4°C and non-linearity of 1.1%. Results of this study suggest that the sensing core is ready to be integrated in the sensing unit, where system integration is the subject matter of a parallel effort. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. AUTOMATIC COUNTER

    DOEpatents

    Robinson, H.P.

    1960-06-01

    An automatic counter of alpha particle tracks recorded by a sensitive emulsion of a photographic plate is described. The counter includes a source of mcdulated dark-field illumination for developing light flashes from the recorded particle tracks as the photographic plate is automatically scanned in narrow strips. Photoelectric means convert the light flashes to proportional current pulses for application to an electronic counting circuit. Photoelectric means are further provided for developing a phase reference signal from the photographic plate in such a manner that signals arising from particle tracks not parallel to the edge of the plate are out of phase with the reference signal. The counting circuit includes provision for rejecting the out-of-phase signals resulting from unoriented tracks as well as signals resulting from spurious marks on the plate such as scratches, dust or grain clumpings, etc. The output of the circuit is hence indicative only of the tracks that would be counted by a human operator.

  3. Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III)

    NASA Technical Reports Server (NTRS)

    Doke, T.; Hayashi, T.; Borak, T. B.; Chatterjee, A. (Principal Investigator)

    2001-01-01

    Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.

  4. Development of an X-ray surface analyzer for planetary exploration

    NASA Technical Reports Server (NTRS)

    Clark, B. C.

    1972-01-01

    An ultraminiature X-ray fluorescence spectrometer was developed which can obtain data on element composition not provided by present spacecraft instrumentation. The apparatus employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a soil sample. Fluorescent X-rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to several percent, depending upon the element and the matrix. For most elements, they are below 0.5 percent. Accuracies likewise depend upon the matrix, but are generally better than plus or minus 0.5 percent for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group.

  5. Neutron counter based on beryllium activation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bienkowska, B.; Prokopowicz, R.; Kaczmarczyk, J.

    2014-08-21

    The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large areamore » gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.« less

  6. The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon

    NASA Technical Reports Server (NTRS)

    Gersey, B. B.; Borak, T. B.; Guetersloh, S. B.; Zeitlin, C.; Miller, J.; Heilbronn, L.; Murakami, T.; Iwata, Y.; Chatterjee, A. (Principal Investigator)

    2002-01-01

    The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.

  7. Measurement of microdosimetric spectra with a wall-less tissue-equivalent proportional counter for a 290 MeV/u 12C beam.

    PubMed

    Tsuda, Shuichi; Sato, Tatsuhiko; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira; Sasaki, Shinichi; Namito, Yoshihito; Iwase, Hiroshi; Ban, Shuichi; Takada, Masashi

    2010-09-07

    The frequency distribution of the lineal energy, y, of a 290 MeV/u carbon beam was measured to obtain the dose-weighted mean of y and compare it with the linear energy transfer (LET). In the experiment, a wall-less tissue-equivalent proportional counter (TEPC) in a cylindrical volume with a simulated diameter of 0.72 microm was used. The measured frequency distribution of y as well as its dose-mean value agrees within 10% uncertainty with the corresponding data from microdosimetric calculations using the PHITS code. The ratio of the measured dose-mean lineal energy to the LET of the 290 MeV/u carbon beam is 0.73, which is much smaller than the corresponding data obtained by a wall TEPC. This result demonstrates that a wall-less TEPC is necessary to precisely measure the dose-mean of y for energetic heavy ion beams.

  8. MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER.

    PubMed

    Chiriotti, S; Parisi, A; Vanhavere, F; De Saint-Hubert, M; Vandevoorde, C; Slabbert, J; Beukes, P; de Kock, E; Symons, J

    2018-04-13

    Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

  9. X-ray observations of LMC X-3 with the monitor proportional counter aboard the HEAO 2 Einstein observatory - A comparison with Cygnus X-1

    NASA Technical Reports Server (NTRS)

    Weisskopf, M. C.; Darbro, W. A.; Elsner, R. F.; Williams, A. C.; Kahn, S. M.; Grindlay, J. E.; Naranan, S.; Sutherland, P. G.

    1983-01-01

    A comparison is presented of the black hole candidates LMC X-3 and Cygnus X-1 based on Einstein observations of LMC X-3 with the monitor proportional counter. A spectral analysis shows LMC X-3 to be more like the typical bright galactic X-ray source than Cygnus X-1. A search for periodic pulsations over a period range from 0.2 ms to over 1000 s set upper limits at the 90 percent confidence level of the order of 10 percent. An analysis of the aperiodic variability of LMC X-3 shows none of the shot noise behavior characteristic of Cygnus X-1. The absence of distinctive X-ray properties common to both sources suggests that the identification of black hole candidates on the basis of X-ray properties similar to Cygnus X-1 (or LMC X-3) is not reliable.

  10. The counter and consultation room work explored in the Netherlands.

    PubMed

    Mobach, Mark P

    2008-08-01

    To determine the frequency and nature of conversations at the counter and of private consultations at three Dutch community pharmacies. In a purposive and convenience sample of three Dutch community pharmacies two work categories were investigated: counter work and consultation room work with self-reporting tally. The study took 6 weeks: 2 weeks at each pharmacy. The number of care related conversations and consultations emerging in the counter work and consultation room work. About 43% of all counter conversations consisted of the provision of pharmaceutical information and 72% of the consultations in the separate consultation room dealt with care related activities. However, only 18 consultations were held in this latter room: 0.4% of all reported conversations. The proportion of care related work at the counter and in the consultation room did have significant substance. There are however serious possibilities to change pharmaceutical care for the better. It is suggested that standard procedures at the counter may help increasing care related work. The presence of a separate consultation room may increase the number of consultations held in private, when combined with raising patient awareness of its existence.

  11. Carbon-14 dating of small samples by proportional counting.

    PubMed

    Harbottle, G; Sayre, E V; Stoenner, R W

    1979-11-09

    Conventional carbon-14 dating by means of gas proportional counters has been extended to samples containing as little as 10 milligrams of carbon. The accuracy of the dating procedure has been checked by dating sequoia tree-ring samples of the 1st century A.D. and B.C. and an oak tree-ring sample of the 19th century A.D.

  12. Multi-anode wire two dimensional proportional counter for detecting Iron-55 X-Ray Radiation

    NASA Astrophysics Data System (ADS)

    Weston, Michael William James

    Radiation detectors in many applications use small sensor areas or large tubes which only collect one-dimensional information. There are some applications that require analyzing a large area and locating specific elements such as contamination on the heat tiles of a space shuttle or features on historical artifacts. The process can be time consuming and scanning a large area in a single pass is beneficial. The use of a two dimensional multi-wire proportional counter provides a large detection window presenting positional information in a single pass. This thesis described the design and implementation of an experimental detector to evaluate a specific design intended for use as a handheld instrument. The main effort of this research was to custom build a detector for testing purposes. The aluminum chamber and all circuit boards were custom designed and built specifically for this application. Various software and programmable logic algorithms were designed to analyze the raw data in real time and attempted to determine what data was useful and what could be discarded. The research presented here provides results useful for designing an improved second generation detector in the future. With the anode wire spacing chosen and the minimal collimation of the radiation source, detected events occurred all over the detection grid at any time. The raw event data did not make determining the source position easy and further data correlation was required. An abundance of samples had multiple wire hits which were not useful because it falsely reported the source to be all over the place and at different energy levels. By narrowing down the results to only use the largest signal pairs on different axes in each event, a much more accurate analysis of where the source existed above the grid was determined. The basic principle and construction method was shown to work, however the gas selection, geometry and anode wire constructs proved to be poor. To provide a system optimized

  13. Deep high-resolution fluorescence microscopy of full organs: the benefit of ultraminiature confocal miniprobes

    NASA Astrophysics Data System (ADS)

    Schwarz, France; Le Nevez, Arnaud; Genet, Magalie; Osdoit, Anne; Lacombe, François

    2009-02-01

    Background: Confocal Laser Endomicroscopy (CLE) based on ultraminiature miniprobes (Cellvizio®, Mauna Kea Technologies, Paris, France) is able to image the inner microstructure of retroperitoneal full organs punctured during EUS-FNA procedures, such as pancreas, liver or lymph nodes. Therefore, pCLE can provide an easy-to-use and precise adjunct tool to ultrasonographic interventions in order to target suspicious areas for biopsies in EUS-FNA. Material and Methods: Probe-based CLE (pCLE) was performed on ex-vivo surgically resected specimens after topical application of fluorophores in standard 19G and 22G needles. Two prototype miniprobes ("S-probe" 300 microns diameter, field of view 400*280 microns, and "S-probe" 650 microns diameter, field of view 500*600 microns) were then inserted into the needles and enabled visualization of the inner microstructures of uterus, lung, kidney, stomach and esophagus, in both healthy and cancerous conditions. Then, pCLE was performed in-vivo on four pigs during three NOTES and one EUS-FNA procedures after intravenous injection of 2-7mL fluorescein 1-10% using the prototype "S-probe" 350 microns diameter inserted in 19G FNA needles. Liver, pancreas and spleen were imaged. Results: During the ex-vivo experiments, pCLE made it possible to distinguish microstructures, such as alveoli and macrophages in the lungs. During the in-vivo experiments, Cellvizio® video sequences showed hepatic lobules and the portal vein in the liver, and red and white pulp in the spleen. Conclusion: pCLE provides in vivo cellular information about full organs. It has the potential to help target biopsies during EUSFNA, which suffers from a high rate of false negatives, thus increasing its sensitivity.

  14. Quantitative basis for component factors of gas flow proportional counting efficiencies

    NASA Astrophysics Data System (ADS)

    Nichols, Michael C.

    This dissertation investigates the counting efficiency calibration of a gas flow proportional counter with beta-particle emitters in order to (1) determine by measurements and simulation the values of the component factors of beta-particle counting efficiency for a proportional counter, (2) compare the simulation results and measured counting efficiencies, and (3) determine the uncertainty of the simulation and measurements. Monte Carlo simulation results by the MCNP5 code were compared with measured counting efficiencies as a function of sample thickness for 14C, 89Sr, 90Sr, and 90Y. The Monte Carlo model simulated strontium carbonate with areal thicknesses from 0.1 to 35 mg cm-2. The samples were precipitated as strontium carbonate with areal thicknesses from 3 to 33 mg cm-2 , mounted on membrane filters, and counted on a low background gas flow proportional counter. The estimated fractional standard deviation was 2--4% (except 6% for 14C) for efficiency measurements of the radionuclides. The Monte Carlo simulations have uncertainties estimated to be 5 to 6 percent for carbon-14 and 2.4 percent for strontium-89, strontium-90, and yttrium-90. The curves of simulated counting efficiency vs. sample areal thickness agreed within 3% of the curves of best fit drawn through the 25--49 measured points for each of the four radionuclides. Contributions from this research include development of uncertainty budgets for the analytical processes; evaluation of alternative methods for determining chemical yield critical to the measurement process; correcting a bias found in the MCNP normalization of beta spectra histogram; clarifying the interpretation of the commonly used ICRU beta-particle spectra for use by MCNP; and evaluation of instrument parameters as applied to the simulation model to obtain estimates of the counting efficiency from simulated pulse height tallies.

  15. Distributed performance counters

    DOEpatents

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  16. Measurement of the stochastic radial dose distribution for a 30-MeV proton beam using a wall-less tissue-equivalent proportional counter

    PubMed Central

    Tsuda, S.; Sato, T.; Ogawa, T.

    2016-01-01

    The frequency distribution of the lineal energy, y, of a 30-MeV proton beam was measured as a function of the radial distance from the beam path, and the dosed mean of y,y¯D, was obtained to investigate the radial dependence of y¯D. A wall-less tissue-equivalent proportional counter, in a cylindrical volume with simulated diameters of 0.36, 0.72 and 1.44 µm was used for the measurement of y distributions, yf(y). The measured values of yf(y) summed in the radial direction agreed fairly well with the corresponding data taken from the microdosimetric calculations using the PHITS code. The y¯D value of the 30-MeV proton beam presented its smallest value at r = 0.0 and gradually increased with radial distance, and the y¯D values of heavy ions such as iron showed rapid decrease with radial distance. This experimental result demonstrated that the stochastic deposited energy distribution of high-energy protons in the microscopic region is rather constant in the core as well as in the penumbra region of the track structure. PMID:25956785

  17. Proportional counter device for detecting electronegative species in an air sample

    DOEpatents

    Allman, Steve L.; Chen, Fang C.; Chen, Chung-Hsuan

    1994-01-01

    Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species.

  18. Proportional counter device for detecting electronegative species in an air sample

    DOEpatents

    Allman, S.L.; Chen, F.C.; Chen, C.H.

    1994-03-08

    Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species. 2 figures.

  19. Over-the-counter medications containing diphenhydramine and doxylamine used by older adults to improve sleep.

    PubMed

    Abraham, Olufunmilola; Schleiden, Loren; Albert, Steven M

    2017-08-01

    Background The unintentional misuse of over-the-counter sleep aids among older adults is an important public health problem and a focus of Healthy People 2020. Accordingly, the 2015 Beers Criteria for Potentially Inappropriate Medication Use in Older Adults recommends that individuals 65 years or older avoid use of diphenhydramine and doxylamine; however, many over-the-counter sleep products contain these active ingredients. Objective To identify the proportion of older adults using an over-the-counter medication containing diphenhydramine or doxylamine, and compare their characteristics with older adults using an over-the-counter medication that does not contain these ingredients. Setting Study participants were recruited from the Community Registry of the Pittsburgh Claude D. Pepper Older Americans Independence Center. Method The study sample was taken from a larger survey of 1025 participants on sleep health and over-the-counter sleep medication use conducted from February to April 2015. A subset of 169 participants aged 65 and older reporting taking at least one over-the-counter product to improve sleep within the past 30 days (16.5%) were selected for our analysis on associations between participant characteristics and potentially inappropriate use of over-the-counter sleep medications. Main outcome measure The proportion and characteristics of older adults taking at least one over-the-counter medication containing diphenhydramine or doxylamine. Results Of the 223 over-the-counter sleep medications listed by participants, 115 (52%) contained diphenhydramine or doxylamine. Using the Beers Criteria, we found that more than half of participants (59%) had used a potentially inappropriate over-the-counter medication containing diphenhydramine or doxylamine to improve sleep within the past 30 days. Participants taking at least one diphenhydramine or doxylamine containing medication were less likely to be aware of any safety risks in taking over-the-counter sleep

  20. The response of a scintillation counter below an emulsion chamber to heavy nucleus interactions in the chamber

    NASA Technical Reports Server (NTRS)

    Burnett, T. H.; Dake, S.; Derrickson, J. H.; Fountain, W. F.; Fuki, M.; Gregory, J. C.; Hayashi, T.; Hayashi, T.; Holynski, R.; Iwai, J.; hide

    1985-01-01

    In 1982 a hybrid electronic counter-emulsion chamber experiment was flown on a balloon to study heavy nucleus interactions in the 20 to approximately 100 GeV/AMU energy range. A gas Cerenkov counter, two solid Cerenkov counters, and a proportional counter hodoscope gave the primary energy, the primary charge and the trajectory of the particles, respectively. Using the trajectory information cosmic ray nuclei of Z 10 were found reliably and efficiently, and interaction characteristics of the Fe group nuclei were measured in the chamber. A plastic scintillator below the emulsion chamber responded to showers resulting from interactions in the chamber and to noninteracting nuclei. Data on the response of the counter have been compared with simulations of hadronic-electromagnetic cascades to derive the average neutral energy fraction released by the heavy interactions, and to predict the performance of this kind of counter at higher energies. For the interacting events of highest produced particles multiplicity comparison between various simulations and the shower counter signal have been made.

  1. Measurement of the stochastic radial dose distribution for a 30-MeV proton beam using a wall-less tissue-equivalent proportional counter.

    PubMed

    Tsuda, S; Sato, T; Ogawa, T

    2016-02-01

    The frequency distribution of the lineal energy, y, of a 30-MeV proton beam was measured as a function of the radial distance from the beam path, and the dosed mean of y, y¯(D), was obtained to investigate the radial dependence of y¯(D). A wall-less tissue-equivalent proportional counter, in a cylindrical volume with simulated diameters of 0.36, 0.72 and 1.44 µm was used for the measurement of y distributions, yf(y). The measured values of yf(y) summed in the radial direction agreed fairly well with the corresponding data taken from the microdosimetric calculations using the PHITS code. The y¯(D) value of the 30-MeV proton beam presented its smallest value at r = 0.0 and gradually increased with radial distance, and the y¯(D) values of heavy ions such as iron showed rapid decrease with radial distance. This experimental result demonstrated that the stochastic deposited energy distribution of high-energy protons in the microscopic region is rather constant in the core as well as in the penumbra region of the track structure. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Systematic measurement of lineal energy distributions for proton, He and Si ion beams over a wide energy range using a wall-less tissue equivalent proportional counter.

    PubMed

    Tsuda, Shuichi; Sato, Tatsuhiko; Takahashi, Fumiaki; Satoh, Daiki; Sasaki, Shinichi; Namito, Yoshihito; Iwase, Hiroshi; Ban, Shuichi; Takada, Masashi

    2012-01-01

    The frequency distributions of the lineal energy, y, of 160 MeV proton, 150 MeV/u helium, and 490 MeV/u silicon ion beams were measured using a wall-less tissue equivalent proportional counter (TEPC) with a site size of 0.72 µm. The measured frequency distributions of y as well as the dose-mean values, y(D), agree with the corresponding data calculated using the microdosimetric function of the particle and heavy ion transport code system PHITS. The values of y(D) increase in the range of LET below ~10 keV µm(-1) because of discrete energy deposition by delta rays, while the relation is reversed above ~10 keV µm(-1) as the amount of energy escaping via delta rays increases. These results indicate that care should be taken with the difference between y(D) and LET when estimating the ionization density that usually relates to relative biological effectiveness (RBE) of energetic heavy ions.

  3. Measurement and simulation of lineal energy distribution at the CERN high energy facility with a tissue equivalent proportional counter.

    PubMed

    Rollet, S; Autischer, M; Beck, P; Latocha, M

    2007-01-01

    The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been studied. The measurements have been done at the CERN-EU High-Energy Reference Field (CERF) facility where a well-characterised radiation field is available for intercomparison. The TEPC instrument used by the ARC Seibersdorf Research is filled with pure propane gas at low pressure and can be used to determine the lineal energy distribution of the energy deposition in a mass of gas equivalent to a 2 microm diameter volume of unit density tissue, of similar size to the nuclei of biological cells. The linearity of the detector response was checked both in term of dose and dose rate. The effect of dead-time has been corrected. The influence of the detector exposure location and orientation in the radiation field on the dose distribution was also studied as a function of the total dose. The microdosimetric distribution of the absorbed dose as a function of the lineal energy has been obtained and compared with the same distribution simulated with the FLUKA Monte Carlo transport code. The dose equivalent was calculated by folding this distribution with the quality factor as a function of linear energy transfer. The comparison between the measured and simulated distributions show that they are in good agreement. As a result of this study the detector is well characterised, thanks also to the numerical simulations the instrument response is well understood, and it's currently being used onboard the aircrafts to evaluate the dose to aircraft crew caused by cosmic radiation.

  4. Imaging proportional counters for the stellar X-ray polarimeter. [on Soviet Spectrum X-Gamma mission

    NASA Technical Reports Server (NTRS)

    Watkins, R. B., Jr.; Kaaret, P.

    1990-01-01

    The xenon-filled IPCs being developed for the Stellar X-ray Polarimeter are described. The requirements placed on the IPCs by the design of the polarimeter are discussed and results on the performance of prototype counters are presented. The design of a prototype of the IPCs is described. Finally, the performance of the prototype is reported. Due to the extremely low count rates encountered in X-ray polarimetry, efficient background rejection is the most critical parameter of the IPCs. Using a background rejection scheme employing anticoincidence and pulse shape discrimination, a rejection efficiency of 99 percent has been achieved for Co-60-induced events over an energy range of 2 to 15 keV while retaining more than 80 percent of the X-ray efficiency.

  5. FLEXIBLE GEIGER COUNTER

    DOEpatents

    Richter, H.G.; Gillespie, A.S. Jr.

    1963-11-12

    A flexible Geiger counter constructed from materials composed of vinyl chloride polymerized with plasticizers or co-polymers is presented. The counter can be made either by attaching short segments of corrugated plastic sleeving together, or by starting with a length of vacuum cleaner hose composed of the above materials. The anode is maintained substantially axial Within the sleeving or hose during tube flexing by means of polystyrene spacer disks or an easily assembled polyethylene flexible cage assembly. The cathode is a wire spiraled on the outside of the counter. The sleeving or hose is fitted with glass end-pieces or any other good insulator to maintain the anode wire taut and to admit a counting gas mixture into the counter. Having the cathode wire on the outside of the counter substantially eliminates the objectional sheath effect of prior counters and permits counting rates up to 300,000 counts per minute. (AEC)

  6. The acetone bandpass detector for inverse photoemission: operation in proportional and Geiger–Müller modes

    NASA Astrophysics Data System (ADS)

    Thiede, Christian; Niehues, Iris; Schmidt, Anke B.; Donath, Markus

    2018-06-01

    Inverse photoemission is the most versatile experimental tool to study the unoccupied electronic structure at surfaces of solids. Typically, the experiments are performed in the isochromat mode with bandpass photon detectors. For gas-filled counters, the bandpass behavior is realized by the combination of the photoionization threshold of the counting gas as the high-pass filter and the ultraviolet transmission cutoff of an alkaline earth fluoride entrance window as the low-pass filter. The transmission characteristics of the entrance window determine the optical bandpass. The performance of the counter depends on the composition of the detection gas and the fill-gas pressure, the readout electronics and the counter geometry. For the well-known combination of acetone and CaF2, the detector can be operated in proportional and Geiger–Müller modes. In this work, we review aspects concerning the working principles, the counter construction and the read-out electronics. We identify optimum working parameters and provide a step-by-step recipe how to build, install and operate the device.

  7. Radial dependence of lineal energy distribution of 290-MeV/u carbon and 500-MeV/u iron ion beams using a wall-less tissue-equivalent proportional counter

    PubMed Central

    Tsuda, Shuichi; Sato, Tatsuhiko; Watanabe, Ritsuko; Takada, Masashi

    2015-01-01

    Using a wall-less tissue-equivalent proportional counter for a 0.72-μm site in tissue, we measured the radial dependence of the lineal energy distribution, yf(y), of 290-MeV/u carbon ions and 500-MeV/u iron ion beams. The measured yf(y) distributions and the dose-mean of y, y¯D, were compared with calculations performed with the track structure simulation code TRACION and the microdosimetric function of the Particle and Heavy Ion Transport code System (PHITS). The values of the measured y¯D were consistent with calculated results within an error of 2%, but differences in the shape of yf(y) were observed for iron ion irradiation. This result indicates that further improvement of the calculation model for yf(y) distribution in PHITS is needed for the analytical function that describes energy deposition by delta rays, particularly for primary ions having linear energy transfer in excess of a few hundred keV μm−1. PMID:25210053

  8. Low latency counter event indication

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2008-09-16

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  9. Low latency counter event indication

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-08-24

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  10. Samus Counter Lifting Fixture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stredde, H.; /Fermilab

    1998-05-27

    A lifting fixture has been designed to handle the Samus counters. These counters are being removed from the D-zero area and will be transported off site for further use at another facility. This fixture is designed specifically for this particular application and will be transferred along with the counters. The future use of these counters may entail installation at a facility without access to a crane and therefore a lift fixture suitable for both crane and/or fork lift usage has been created The counters weigh approximately 3000 lbs. and have threaded rods extended through the counter at the top comersmore » for lifting. When these counters were first handled/installed these rods were used in conjunction with appropriate slings and handled by crane. The rods are secured with nuts tightened against the face of the counter. The rod thread is M16 x 2({approx}.625-inch dia.) and extends 2-inch (on average) from the face of the counter. It is this cantilevered rod that the lift fixture engages with 'C' style plates at the four top comers. The strongback portion of the lift fixture is a steel rectangular tube 8-inch (vertical) x 4-inch x .25-inch wall, 130-inch long. 1.5-inch square bars are welded perpendicular to the long axis of the rectangular tube at the appropriate lift points and the 'C' plates are fastened to these bars with 3/4-10 high strength bolts -grade 8. Two short channel sections are positioned-welded-to the bottom of the rectangular tube on 40 feet centers, which are used as locators for fork lift tines. On the top are lifting eyes for sling/crane usage and are rated at 3500 lbs. safe working load each - vertical lift only.« less

  11. Portable multiplicity counter

    DOEpatents

    Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM

    2009-09-01

    A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.

  12. Redundant operation of counter modules

    NASA Technical Reports Server (NTRS)

    Nagano, S. (Inventor)

    1980-01-01

    A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

  13. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  14. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-03-30

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  15. GASEOUS SCINTILLATION COUNTER

    DOEpatents

    Eggler, C.; Huddleston, C.M.

    1959-04-28

    A gaseous excitation counter for detecting the presence amd measuring the energy of subatomic particles and electromagnetic radiation is described. The counter includes a gas-tight chamber filled with an elemental gas capable of producing ultra-violet excitation quanta when irradiated with subatomic particles and electromagnetic radiation. The gas has less than one in a thousand parts ultra-violet absorbing contamination. When nuclear radiation ps present the ultra-violet light produced by the gas strikes a fluorescent material within the counter, responsive to produce visible excitation quanta, and photo-sensitive counting means detect the visible emission.

  16. Over-the-counter Acne Treatments

    PubMed Central

    Graber, Emmy M.

    2012-01-01

    Acne is a common dermatological disorder that most frequently affects adolescents; however, individuals may be affected at all ages. Many people who suffer from acne seek treatment from both prescription and over-the-counter acne medications. Due to convenience, lower cost, and difficulty getting an appointment with a dermatologist, the use of over-the-counter acne treatments is on the rise. As the plethora of over-the-counter acne treatment options can be overwhelming, it is important that dermatologists are well-versed on this subject to provide appropriate information about treatment regimens and potential drug interactions and that their patients see them as well-informed. This article reviews the efficacy of various over-the-counter acne treatments based on the current literature. A thorough literature review revealed there are many types of over-the-counter acne treatments and each are designed to target at least one of the pathogenic pathways that are reported to be involved in the development of acne lesions. Many of the key over-the-counter ingredients are incorporated in different formulations to broaden the spectrum and consumer appeal of available products. Unfortunately, many over-the-counter products are not well-supported by clinical studies, with a conspicuous absence of double-blind or investigator-blind, randomized, vehicle-controlled studies. Most studies that do exist on over-the-counter acne products are often funded by the manufacturer. Use of over-the-counter acne treatments is a mainstay in our society and it is important that dermatologists are knowledgeable about the different options, including potential benefits and limitations. Overall, over-the-counter acne therapies can be classified into the following five major groups: cleansers, leave-on products, mechanical treatments, essential oils, and vitamins. PMID:22808307

  17. Countering Threat Networks

    DTIC Science & Technology

    2016-12-21

    PLANNING TO COUNTER THREAT NETWORKS  Joint Intelligence Preparation of the Operational Environment and Threat Networks...Army Expeditionary Forensic Facility in Afghanistan ........ E-9 E-4 Exploitation Support to Intelligence Fusion and Decision Making ......... E-10...Approach The groundwork for successful countering threat networks activities starts with information and intelligence to develop an understanding

  18. Radial dependence of lineal energy distribution of 290-MeV/u carbon and 500-MeV/u iron ion beams using a wall-less tissue-equivalent proportional counter.

    PubMed

    Tsuda, Shuichi; Sato, Tatsuhiko; Watanabe, Ritsuko; Takada, Masashi

    2015-01-01

    Using a wall-less tissue-equivalent proportional counter for a 0.72-μm site in tissue, we measured the radial dependence of the lineal energy distribution, yf(y), of 290-MeV/u carbon ions and 500-MeV/u iron ion beams. The measured yf(y) distributions and the dose-mean of y, [Formula: see text], were compared with calculations performed with the track structure simulation code TRACION and the microdosimetric function of the Particle and Heavy Ion Transport code System (PHITS). The values of the measured [Formula: see text] were consistent with calculated results within an error of 2%, but differences in the shape of yf(y) were observed for iron ion irradiation. This result indicates that further improvement of the calculation model for yf(y) distribution in PHITS is needed for the analytical function that describes energy deposition by delta rays, particularly for primary ions having linear energy transfer in excess of a few hundred keV μm(-1). © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  19. Sign-And-Magnitude Up/Down Counter

    NASA Technical Reports Server (NTRS)

    Cole, Steven W.

    1991-01-01

    Magnitude-and-sign counter includes conventional up/down counter for magnitude part and special additional circuitry for sign part. Negative numbers indicated more directly. Counter implemented by programming erasable programmable logic device (EPLD) or programmable logic array (PLA). Used in place of conventional up/down counter to provide sign and magnitude values directly to other circuits.

  20. Over-the-Counter Medicines

    MedlinePlus

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. Some prevent or cure ... the Food and Drug Administration decides whether a medicine is safe enough to sell over-the-counter. ...

  1. Counter-transference and counter-experience in the treatment of violence prone youth.

    PubMed

    King, C H

    1976-01-01

    The constant confrontation inherent in therapeutic intervention with violence prone children, some of whome have committed homicide, is explored. Problems unique to work with these youths are discussed in terms of counter-transference issues for clinicians and counter-experience of teachers and child care workers. Suggestions for training and supervision are offered.

  2. Instability of counter-rotating stellar disks

    NASA Astrophysics Data System (ADS)

    Hohlfeld, R. G.; Lovelace, R. V. E.

    2015-09-01

    We use an N-body simulation, constructed using GADGET-2, to investigate an accretion flow onto an astrophysical disk that is in the opposite sense to the disk's rotation. In order to separate dynamics intrinsic to the counter-rotating flow from the impact of the flow onto the disk, we consider an initial condition in which the counter-rotating flow is in an annular region immediately exterior the main portion of the astrophysical disk. Such counter-rotating flows are seen in systems such as NGC 4826 (known as the "Evil Eye Galaxy"). Interaction between the rotating and counter-rotating components is due to two-stream instability in the boundary region. A multi-armed spiral density wave is excited in the astrophysical disk and a density distribution with high azimuthal mode number is excited in the counter-rotating flow. Density fluctuations in the counter-rotating flow aggregate into larger clumps and some of the material in the counter-rotating flow is scattered to large radii. Accretion flow processes such as this are increasingly seen to be of importance in the evolution of multi-component galactic disks.

  3. Basic design of a multi wire proportional counter using Garfield++ for ILSF

    NASA Astrophysics Data System (ADS)

    Ghahremani Gol, M.; Ashrafi, S.; Rahighi, J.

    2016-12-01

    The Iranian Light Source Facility (ILSF) is a new 3 GeV third generation synchrotron radiation facility in Middle East, which at the time being is in its design stage. An important aspect for the scientific success of this new source will be the availability of well adapted detectors. Position-sensitive X-ray detectors have played an important role in synchrotron radiation X-ray experiments for many years and are still in use. An operational one-dimensional multiwire position sensitive detector with delay line readout produced by ILSF showed a position resolution of 230 μm. In this paper, we introduce a 2-D position sensitive gas detector based on a multiwire proportional chamber which will be used in small/wide angle scattering and diffraction experiments with synchrotron radiation at the ILSF. The parameters of its components, including the gas filling, gas pressure, temperature, the geometry of anode and cathodes planes as well as the expected performance of the designed system will be described in the following. For the design and the simulation of MWPC the Elmer and Garfield++ codes have been employed. We have built and tested a MWPC as a prototype at ILSF. The results obtained so far show a good position sensing. After primary test the detector has been optimized and is now ready for test at Elettra.

  4. Counter-Learning under Oppression

    ERIC Educational Resources Information Center

    Kucukaydin, Ilhan

    2010-01-01

    This qualitative study utilized the method of narrative analysis to explore the counter-learning process of an oppressed Kurdish woman from Turkey. Critical constructivism was utilized to analyze counter-learning; Frankfurt School-based Marcusian critical theory was used to analyze the sociopolitical context and its impact on the oppressed. Key…

  5. Counter-rotating accretion discs

    NASA Astrophysics Data System (ADS)

    Dyda, S.; Lovelace, R. V. E.; Ustyugova, G. V.; Romanova, M. M.; Koldoba, A. V.

    2015-01-01

    Counter-rotating discs can arise from the accretion of a counter-rotating gas cloud on to the surface of an existing corotating disc or from the counter-rotating gas moving radially inwards to the outer edge of an existing disc. At the interface, the two components mix to produce gas or plasma with zero net angular momentum which tends to free-fall towards the disc centre. We discuss high-resolution axisymmetric hydrodynamic simulations of viscous counter-rotating discs for the cases where the two components are vertically separated and radially separated. The viscosity is described by an isotropic α-viscosity including all terms in the viscous stress tensor. For the vertically separated components, a shear layer forms between them and the middle part of this layer free-falls to the disc centre. The accretion rates are increased by factors of ˜102-104 over that for a conventional disc rotating in one direction with the same viscosity. The vertical width of the shear layer and the accretion rate are strongly dependent on the viscosity and the mass fraction of the counter-rotating gas. In the case of radially separated components where the inner disc corotates and the outer disc rotates in the opposite direction, a gap between the two components opens and closes quasi-periodically. The accretion rates are ≳25 times larger than those for a disc rotating in one direction with the same viscosity.

  6. Modular high speed counter employing edge-triggered code

    DOEpatents

    Vanstraelen, Guy F.

    1993-06-29

    A high speed modular counter (100) utilizing a novel counting method in which the first bit changes with the frequency of the driving clock, and changes in the higher order bits are initiated one clock pulse after a "0" to "1" transition of the next lower order bit. This allows all carries to be known one clock period in advance of a bit change. The present counter is modular and utilizes two types of standard counter cells. A first counter cell determines the zero bit. The second counter cell determines any other higher order bit. Additional second counter cells are added to the counter to accommodate any count length without affecting speed.

  7. Modular high speed counter employing edge-triggered code

    DOEpatents

    Vanstraelen, G.F.

    1993-06-29

    A high speed modular counter (100) utilizing a novel counting method in which the first bit changes with the frequency of the driving clock, and changes in the higher order bits are initiated one clock pulse after a 0'' to 1'' transition of the next lower order bit. This allows all carries to be known one clock period in advance of a bit change. The present counter is modular and utilizes two types of standard counter cells. A first counter cell determines the zero bit. The second counter cell determines any other higher order bit. Additional second counter cells are added to the counter to accommodate any count length without affecting speed.

  8. Real-time {sup 90}Sr Counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray ofmore » maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  9. Multiple channel programmable coincidence counter

    DOEpatents

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  10. Basic Research Needs for Countering Terrorism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, W.; Michalske, T.; Trewhella, J.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  11. Synchronization in counter-rotating oscillators.

    PubMed

    Bhowmick, Sourav K; Ghosh, Dibakar; Dana, Syamal K

    2011-09-01

    An oscillatory system can have opposite senses of rotation, clockwise or anticlockwise. We present a general mathematical description of how to obtain counter-rotating oscillators from the definition of a dynamical system. A type of mixed synchronization emerges in counter-rotating oscillators under diffusive scalar coupling when complete synchronization and antisynchronization coexist in different state variables. We present numerical examples of limit cycle van der Pol oscillator and chaotic Rössler and Lorenz systems. Stability conditions of mixed synchronization are analytically obtained for both Rössler and Lorenz systems. Experimental evidences of counter-rotating limit cycle and chaotic oscillators and mixed synchronization are given in electronic circuits.

  12. GEIGER-MULLER TYPE COUNTER TUBE

    DOEpatents

    Fowler, I.L.; Watt, L.A.K.

    1959-12-15

    A single counter tube capable of responding to a wide range of intensities is described. The counter tube comprises a tubular cathode and an anode extending centrally of the cathode. The spacing between the outer surface of the anode and the inner surface of the cathode is varied along the length of the tube to provide different counting volumes in adjacent portions of the tube. A large counting volume in one portion adjacent to a low-energy absorption window gives adequate sensitivity for measuring lowintensity radiation, while a smaller volume with close electrode spacing is provided in the counter to make possible measurement of intense garnma radiation fields.

  13. CALCIUM ABSORPTION IN MAN: BASED ON LARGE VOLUME LIQUID SCINTILLATION COUNTER STUDIES.

    PubMed

    LUTWAK, L; SHAPIRO, J R

    1964-05-29

    A technique has been developed for the in vivo measurement of absorption of calcium in man after oral administration of 1 to 5 microcuries of calcium-47 and continuous counting of the radiation in the subject's arm with a large volume liquid scintillation counter. The maximum value for the arm counting technique is proportional to the absorption of tracer as measured by direct stool analysis. The rate of uptake by the arm is lower in subjects with either the malabsorption syndrome or hypoparathyroidism. The administration of vitamin D increases both the absorption rate and the maximum amount of calcium absorbed.

  14. Novel Designs of Quantum Reversible Counters

    NASA Astrophysics Data System (ADS)

    Qi, Xuemei; Zhu, Haihong; Chen, Fulong; Zhu, Junru; Zhang, Ziyang

    2016-11-01

    Reversible logic, as an interesting and important issue, has been widely used in designing combinational and sequential circuits for low-power and high-speed computation. Though a significant number of works have been done on reversible combinational logic, the realization of reversible sequential circuit is still at premature stage. Reversible counter is not only an important part of the sequential circuit but also an essential part of the quantum circuit system. In this paper, we designed two kinds of novel reversible counters. In order to construct counter, the innovative reversible T Flip-flop Gate (TFG), T Flip-flop block (T_FF) and JK flip-flop block (JK_FF) are proposed. Based on the above blocks and some existing reversible gates, the 4-bit binary-coded decimal (BCD) counter and controlled Up/Down synchronous counter are designed. With the help of Verilog hardware description language (Verilog HDL), these counters above have been modeled and confirmed. According to the simulation results, our circuits' logic structures are validated. Compared to the existing ones in terms of quantum cost (QC), delay (DL) and garbage outputs (GBO), it can be concluded that our designs perform better than the others. There is no doubt that they can be used as a kind of important storage components to be applied in future low-power computing systems.

  15. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell counter. 864.5200 Section 864.5200....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the...

  16. Counter electrodes in dye-sensitized solar cells.

    PubMed

    Wu, Jihuai; Lan, Zhang; Lin, Jianming; Huang, Miaoliang; Huang, Yunfang; Fan, Leqing; Luo, Genggeng; Lin, Yu; Xie, Yimin; Wei, Yuelin

    2017-10-02

    Dye-sensitized solar cells (DSSCs) are regarded as prospective solar cells for the next generation of photovoltaic technologies and have become research hotspots in the PV field. The counter electrode, as a crucial component of DSSCs, collects electrons from the external circuit and catalyzes the redox reduction in the electrolyte, which has a significant influence on the photovoltaic performance, long-term stability and cost of the devices. Solar cells, dye-sensitized solar cells, as well as the structure, principle, preparation and characterization of counter electrodes are mentioned in the introduction section. The next six sections discuss the counter electrodes based on transparency and flexibility, metals and alloys, carbon materials, conductive polymers, transition metal compounds, and hybrids, respectively. The special features and performance, advantages and disadvantages, preparation, characterization, mechanisms, important events and development histories of various counter electrodes are presented. In the eighth section, the development of counter electrodes is summarized with an outlook. This article panoramically reviews the counter electrodes in DSSCs, which is of great significance for enhancing the development levels of DSSCs and other photoelectrochemical devices.

  17. Counter-responses as organizers in adolescent analysis and therapy.

    PubMed

    Richmond, M Barrie

    2004-01-01

    The author introduces Counter-response as a phenomological term to replace theory-burdened terms like counter-transference, counter-identification, and counter-resistance. He discusses the analyst's use of self (drawing on the comparison with Winnicott's use of the object) in processing the expectable destabilizing counter-reactions that occur in working therapeutically with disturbed adolescents and their parents. Further; he discusses the counter-reaction to the patient's narrative, acting-out, and how re-enactments can serve as an organizer for understanding the patient's inner life when the analyst formulates his/her counter-response. Emphasis is placed on the therapist forming his or her own narrative with the adolescent that takes into account the evoked counter-reaction. For this purpose, the author recommends the use of a combined counter-response and metaphor-orienting perspective to acknowledge and work with the denial, illusions, reversal of perspective, and catastrophic anxieties experienced with these adolescents. The counter-response perspective permits the emergence of the disturbed adolescent's novel narrative; however, since these experiences can be destabilizing or disruptive, the author also recommends the use of a personal metaphor to anticipate the reluctance to examining, processing, and formulating the analyst's dysphoric counter-reaction. With the use of the counter-response, the analyst's therapeutic ideal is to achieve a more optimal balance between using accepted narrative theories and exploring novel enactment experiences. His swimming metaphor stratagem is designed to keep the analyst in these difficult encounters.

  18. Compressor surge counter

    DOEpatents

    Castleberry, Kimberly N.

    1983-01-01

    A surge counter for a rotating compressor is provided which detects surging by monitoring the vibration signal from an accelerometer mounted on the shaft bearing of the compressor. The circuit detects a rapid increase in the amplitude envelope of the vibration signal, e.g., 4 dB or greater in less than one second, which is associated with a surge onset and increments a counter. The circuit is rendered non-responsive for a period of about 5 seconds following the detection which corresponds to the duration of the surge condition. This prevents multiple registration of counts during the surge period due to rapid swings in vibration amplitude during the period.

  19. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonicalzi, R. M.; Aalseth, C. E.; Day, A. R.

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill ofmore » P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium counting efficiency while minimizing radiocarbon beta decay interference.« less

  20. Counter-diabatic driving for Dirac dynamics

    NASA Astrophysics Data System (ADS)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  1. Counter traction makes endoscopic submucosal dissection easier.

    PubMed

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  2. Periconceptional Over-the-Counter Nonsteroidal Anti-inflammatory Drug Exposure and Risk for Spontaneous Abortion

    PubMed Central

    Velez Edwards, Digna R.; Aldridge, Tiara; Baird, Donna D.; Funk, Michele Jonsson; Savitz, David A.; Hartmann, Katherine E.

    2012-01-01

    Objective To estimate the association between over-the-counter nonsteroidal anti-inflammatory drug (NSAID) exposure during the early first-trimester and risk for spontaneous abortion (gestation prior to 20 weeks) in a prospective cohort. Methods Women were enrolled in the Right from the Start study (2004–2010). Exposure data regarding over-the-counter NSAID use from the last menstrual period through the 6th week of pregnancy were obtained from intake and first-trimester interviews. Pregnancy outcomes were self-reported and verified by medical records. Gestational age was determined from last menstrual period. Stage of development prior to loss was determined from study ultrasound. Cox proportional hazards regression models were used to estimate the association between NSAID exposure and pregnancy outcome, taking into account candidate confounders. Results Among 2,780 pregnancies, 367 women (13%) experienced an spontaneous abortion. NSAID exposure was reported by 1,185 (43%) women. NSAID exposure was not associated with spontaneous abortion risk in unadjusted models (hazard ratio [HR] = 1.01, 95% confidence interval [CI] 0.82, 1.24) or models adjusted for maternal age (adjusted [aHR] = 1.00, 95% CI 0.81, 1.23). Conclusions Our findings suggest that use of non-prescription over-the-counter NSAIDs in early pregnancy does not put women at increased risk of spontaneous abortion. PMID:22914399

  3. Counter-Punishment, Communication, and Cooperation among Partners

    PubMed Central

    Andrighetto, Giulia; Brandts, Jordi; Conte, Rosaria; Sabater-Mir, Jordi; Solaz, Hector; Székely, Áron; Villatoro, Daniel

    2016-01-01

    We study how communication affects cooperation in an experimental public goods environment with punishment and counter-punishment opportunities. Participants interacted over 30 rounds in fixed groups with fixed identifiers that allowed them to trace other group members' behavior over time. The two dimensions of communication we study are asking for a specific contribution level and having to express oneself when choosing to counter-punish. We conduct four experimental treatments, all involving a contribution stage, a punishment stage, and a counter-punishment stage in each round. In the first treatment communication is not possible at any of the stages. The second treatment allows participants to ask for a contribution level at the punishment stage and in the third treatment participants are required to send a message if they decide to counter-punish. The fourth combines the two communication channels of the second and third treatments. We find that the three treatments involving communication at any of the two relevant stages lead to significantly higher contributions than the baseline treatment. We find no difference between the three treatments with communication. We also relate our results to previous results from treatments without counter-punishment opportunities and do not find that the presence of counter-punishment leads to lower cooperation level. The overall pattern of results shows that given fixed identifiers the key factor is the presence of communication. Whenever communication is possible contributions and earnings are higher than when it is not, regardless of counter-punishment opportunities. PMID:27092065

  4. Simple system for measuring tritium Ad/absorption using a 2. pi. counter and thermal desorption spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyake, H.; Matsuyama, M.; Watanabe, K.

    1992-03-01

    In this paper, the authors develop a simple system using tritium tracer and thermal desorption techniques to measure the tritium adsorption and/or absorption on/in a material having typical surface conditions: namely, not cleaned surface. The tritium counting devices used were a 2{pi} counter and conventional proportional counter. With this system, the amounts of ad/absorption could be measured without exposing the samples to air after exposing them to tritium gas. The overall efficiency (F) of the 2{pi} counter was described at F = exp({minus}2.64h), where h is the distance from the sample to the detector. Ad/absorption measurements were carried out formore » several materials used for fabricating conventional vacuum systems. The results were, in the order of decreasing amounts of ad/absorption, as (fiber reinforced plastics(FRP)) {gt} (nickel(Ni), molybdenum disulfide(MoS{sub 2})) {gt} (stainless steel (SS304), iron(Fe), aluminum alloy(A2219)) {gt} (boron nitride(h-BN), silicon carbide (SiC), SS304 passivated by anodic oxidation layers(ASS) and that by boron nitride segregation layers (BSS)). The relative amounts were abut 100 for Ni and 0.1 for ASS and BSS, being normalized to Fe = 1.« less

  5. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nuclear whole body counter. 892.1130 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1130 Nuclear whole body counter. (a) Identification. A nuclear whole body counter is a device intended to measure the amount of radionuclides in the...

  6. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nuclear whole body counter. 892.1130 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1130 Nuclear whole body counter. (a) Identification. A nuclear whole body counter is a device intended to measure the amount of radionuclides in the...

  7. High resolution time interval counter

    DOEpatents

    Condreva, Kenneth J.

    1994-01-01

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured.

  8. High resolution time interval counter

    DOEpatents

    Condreva, K.J.

    1994-07-26

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured. 3 figs.

  9. Counter design influences the privacy of patients in health care.

    PubMed

    Mobach, Mark P

    2009-03-01

    A re-furnishing of counter areas in primary health care was used to assess patient privacy and its influences on the nature of conversations in a controlled experiment. Patients in two community-based pharmacies in the Netherlands were assigned to enclosed counters and a queue at distance, or to counters that exposed patients mutually and a closer queue. Patients assigned to counters with reduced sight were more satisfied with the privacy than patients at visually exposed counters. However, in comparison with visually exposed pharmacy counters, conversations of patients at enclosed counters could still be overheard and did not have different conversations to other patients. Architectural design of health-care institutions has potential to positively influence perceived patient privacy in areas in where multiple patient-staff communications routinely occur and where patient privacy is an important issue, but enclosed counters with a queue at distance do not prevent incidental disclosure of individually identifiable health information.

  10. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    PubMed

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n) 3 He and D(d,n) 3 He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9 Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  11. Advertising health: the case for counter-ads.

    PubMed Central

    Dorfman, L; Wallack, L

    1993-01-01

    Public service advertisements have been used by many in hopes of "selling" good health behaviors. But selling good behavior--even if it could be done more effectively--is not the best goal for using mass media to prevent health problems. Personal behavior is only part of what determines health status. Social conditions and the physical environment are important determinants of health that are usually ignored by health promotion advertising. Public service advertising may be doing more harm than good if it is diverting attention from more effective socially based health promotion strategies. Counter-ads are one communications strategy that could be used to promote a broader responsibility for rectifying health problems. In the tradition of advocacy advertising directly promoting policy rather than products, counter-ads promote views consistent with a public health perspective. Counter-ads set the agenda for health issues, conferring status on policy-oriented strategies for addressing health problems. The primary purpose of counter-ads is to challenge the dominant view that public health problems reflect personal health habits. They are controversial because they place health issues in a social and political context. Advertising strategies for health promotion range over a spectrum from individually oriented public service advertising to socially oriented counter-advertising. The recent anti-tobacco campaign from the California Department of Health Services represents advertisements across the spectrum. Counter-ads that focus on a politically controversial definition for health problems are an appropriate and necessary alternative to public service advertising. PMID:8265756

  12. Advertising health: the case for counter-ads.

    PubMed

    Dorfman, L; Wallack, L

    1993-01-01

    Public service advertisements have been used by many in hopes of "selling" good health behaviors. But selling good behavior--even if it could be done more effectively--is not the best goal for using mass media to prevent health problems. Personal behavior is only part of what determines health status. Social conditions and the physical environment are important determinants of health that are usually ignored by health promotion advertising. Public service advertising may be doing more harm than good if it is diverting attention from more effective socially based health promotion strategies. Counter-ads are one communications strategy that could be used to promote a broader responsibility for rectifying health problems. In the tradition of advocacy advertising directly promoting policy rather than products, counter-ads promote views consistent with a public health perspective. Counter-ads set the agenda for health issues, conferring status on policy-oriented strategies for addressing health problems. The primary purpose of counter-ads is to challenge the dominant view that public health problems reflect personal health habits. They are controversial because they place health issues in a social and political context. Advertising strategies for health promotion range over a spectrum from individually oriented public service advertising to socially oriented counter-advertising. The recent anti-tobacco campaign from the California Department of Health Services represents advertisements across the spectrum. Counter-ads that focus on a politically controversial definition for health problems are an appropriate and necessary alternative to public service advertising.

  13. Counter - Drug: Mandate for the Army.

    DTIC Science & Technology

    1991-03-01

    this comprehensive review will provide a basis for responding to new missions assigned...observations for determining the short-, mid-, and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide...and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide a basis for responding

  14. Hardware support for software controlled fast multiplexing of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W

    2013-10-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  15. Hardware support for software controlled fast multiplexing of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2013-01-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  16. PULSE COUNTER

    DOEpatents

    Trumbo, D.E.

    1959-02-10

    A transistorized pulse-counting circuit adapted for use with nuclear radiation detecting detecting devices to provide a small, light weight portable counter is reported. The small size and low power requirements of the transistor are of particular value in this instance. The circuit provides an adjustable count scale with a single transistor which is triggered by the accumulated charge on a storage capacitor.

  17. 21 CFR 866.2180 - Manual colony counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual colony counter. 866.2180 Section 866.2180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter...

  18. 21 CFR 866.2180 - Manual colony counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual colony counter. 866.2180 Section 866.2180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter...

  19. 21 CFR 866.2180 - Manual colony counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual colony counter. 866.2180 Section 866.2180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter...

  20. 21 CFR 866.2180 - Manual colony counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual colony counter. 866.2180 Section 866.2180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter...

  1. 21 CFR 866.2180 - Manual colony counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual colony counter. 866.2180 Section 866.2180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter...

  2. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  3. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  4. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  5. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...

  6. Micropipette as Coulter counter for submicron particles

    NASA Astrophysics Data System (ADS)

    Rudzevich, Yauheni; Ordonez, Tony; Evans, Grant; Chow, Lee

    2011-03-01

    Coulter counter based on micropipette has been around for several decades. Typical commercial Coulter counter has a pore size of 20 μ m, and is designed to detect micron-size blood cells. In recent years, there are a lot of interests in using nanometer pore size Coulter counter to detect single molecule and to sequence DNA. Here we describe a simple nanoparticle counter based on pulled micropipettes with a diameter of 50 -- 500 nm. Borosilicate micropipettes with an initial outer diameter of 1.00 mm and inner diameter of 0.5 mm are used. After pulling, the micropipettes are fire polished and ultrasound cleaned. Chlorinated Ag/AgCl electrodes and 0.1 M of KCl solution are used. The ionic currents are measured using an Axopatch 200B amplifier in the voltage-clamp mode. Several types and sizes of nanoparticles are measured, including plain silica and polystyrene nanospheres. The results will be discussed in terms of pH values of the solution and concentrations of the nanoparticles. Financial support from National Science Foundation (NSF-0901361) is acknowledged.

  7. Counter-balanced, multiple cable construction crane

    NASA Astrophysics Data System (ADS)

    Mikulas, Martin M., Jr.; Yang, Li-Farn

    1991-11-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  8. Counter-balanced, multiple cable construction crane

    NASA Astrophysics Data System (ADS)

    Mikulas, Martin M., Jr.; Yang, Li-Farn

    1993-10-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  9. Counter-balanced, multiple cable construction crane

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin M., Jr. (Inventor); Yang, Li-Farn (Inventor)

    1993-01-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  10. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device

    PubMed Central

    Randers-Pehrson, Gerhard; Marino, Stephen A.; Garty, Guy; Harken, Andrew; Brenner, David J.

    2015-01-01

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)3He and D(d,n)3He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima. PMID:26273118

  11. Using DMA for copying performance counter data to memory

    DOEpatents

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance counter data.

  12. 21 CFR 864.5220 - Automated differential cell counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated differential cell counter. 864.5220... § 864.5220 Automated differential cell counter. (a) Identification. An automated differential cell... have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood...

  13. 21 CFR 864.5220 - Automated differential cell counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated differential cell counter. 864.5220... § 864.5220 Automated differential cell counter. (a) Identification. An automated differential cell... have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood...

  14. 21 CFR 864.5220 - Automated differential cell counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated differential cell counter. 864.5220... § 864.5220 Automated differential cell counter. (a) Identification. An automated differential cell... have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood...

  15. 21 CFR 864.5220 - Automated differential cell counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated differential cell counter. 864.5220... § 864.5220 Automated differential cell counter. (a) Identification. An automated differential cell... have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood...

  16. 21 CFR 864.5220 - Automated differential cell counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated differential cell counter. 864.5220... § 864.5220 Automated differential cell counter. (a) Identification. An automated differential cell... have the capability to flag, count, or classify immature or abnormal hematopoietic cells of the blood...

  17. Reactance and Coping Responses to Tobacco Counter-Advertisements.

    PubMed

    Wehbe, Michelle S; Basil, Michael; Basil, Debra

    2017-07-01

    Tobacco prevention messages generally take one of three tactics: They can be educational, attack the tobacco industry, or attack particular brands. Being a smoker and smoking a particular brand may form an essential part of a person's self-identity. As such, reactance theory suggests that attack messages can unintentionally attack smokers' self-image. A 2 × 2 × 2 × 2 experiment using six different messages and 260 respondents tested whether smokers have different reactions to tobacco counter-advertisements than nonsmokers. It also examined whether attacking a smoker's brand leads to greater reactance and other maladaptive responses compared to attacking other brands. Consistent with predictions, smokers reported more maladaptive coping responses and fewer adaptive coping responses to tobacco counter-ads than nonsmokers. The study also reveals differences attributable to brand identification. These findings suggest that interventions should consider different counter-advertising tactics for smokers and nonsmokers. Similar admonitions may apply to counter-advertising strategies on other health issues.

  18. Electromagnetically Operated Counter

    DOEpatents

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  19. Hardware support for software controlled fast reconfiguration of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2013-06-18

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  20. Hardware support for software controlled fast reconfiguration of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W

    2013-09-24

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  1. The Counter Terrorist Classroom: Religion, Education, and Security

    ERIC Educational Resources Information Center

    Gearon, Liam

    2013-01-01

    The article identifies international cases--from the United States, Europe, and the United Nations--of an emergent interface of religion, education, and security. This is manifest in the uses of religion in education to counter religious extremism, the notional "counter terrorist classroom." To avoid an over-association of extremism with…

  2. Counter-Buffing: A Visual Criticism of Guerrilla Advertising

    ERIC Educational Resources Information Center

    Lauzon, Robb Conrad; Cooke, Laquana

    2017-01-01

    This article addresses and explores hip-hop's reclamation of space using transit as a public bulletin. It is situated within counter-publics discourse and couched in the theoretical frameworks offered by visual rhetorical theory. This article also discusses hip-hop counter-publics through guerrilla advertising by former graffiti artists, SKI and…

  3. Picosecond-precision multichannel autonomous time and frequency counter

    NASA Astrophysics Data System (ADS)

    Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  4. Picosecond-precision multichannel autonomous time and frequency counter.

    PubMed

    Szplet, R; Kwiatkowski, P; Różyc, K; Jachna, Z; Sondej, T

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 10 6 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  5. Fuel temperature counter

    Treesearch

    John R. Murray; Charles W. Philpot

    1963-01-01

    Fuel temperature is and has always been difficult to measure. To understand better the problem of fire and fire weather behavior, it is important to measure this variable. We have developed for field use a new fuel temperature counter which can be used to obtain such measurements quickly and easily. This electronic recording instrument is easy to construct and operate...

  6. Laws prohibiting over-the-counter syringe sales to injection drug users: relations to population density, HIV prevalence, and HIV incidence.

    PubMed

    Friedman, S R; Perlis, T; Des Jarlais, D C

    2001-05-01

    This study sought to assess relations of laws prohibiting over-the-counter syringe sales (anti-OTC laws) to population prevalence of injection drug users and HIV prevalence or incidence among 96 US metropolitan areas. A cross-sectional analysis was used. Metropolitan areas with anti-OTC laws had a higher mean HIV prevalence (13.8% vs 6.7%) than other metropolitan areas (pseudo-P < .001). In 83 metropolitan areas with HIV prevalence of less than 20%, anti-OTC laws were associated with HIV incidence rates of 1% or greater (pseudo-P < .001). Population proportions of injection drug users did not vary by presence of anti-OTC laws. Anti-OTC laws are not associated with lower population proportions of injection drug users. Laws restricting syringe access are associated with HIV transmission and should be repealed.

  7. Proportional assist ventilation system based on proportional solenoid valve control.

    PubMed

    Lua, A C; Shi, K C; Chua, L P

    2001-07-01

    A new proportional assist ventilation (PAV) method using a proportional solenoid valve (PSV) to control air supply to patients suffering from respiratory disabilities, was studied. The outlet flow and pressure from the proportional solenoid valve at various air supply pressures were tested and proven to be suitable for pressure and flow control in a PAV system. In vitro tests using a breathing simulator, which has been proven to possess the general characteristics of human respiratory system in spontaneous breathing tests, were conducted and the results demonstrated the viability of this PAV system in normalizing the breathing patterns of patients with abnormally high resistances and elastances as well as neuromuscular weaknesses. With a back-up safety mechanism incorporated in the control program, pressure "run-away" can be effectively prevented and safe operation of the system can be guaranteed.

  8. Light Obscuration Particle Counter Fuel Contamination Limits

    DTIC Science & Technology

    2015-10-08

    or up to 10 mg/L for product used as a diesel product for ground use (1). At a minimum free water and particulate by color (as specified in the...contamination is frequently used in the hydraulics/hydraulic fluid industry. In 1999 ISO adopted ISO 11171 Hydraulic fluid power — Calibration of automatic...particle counters for liquids, replacing ISO 4402, as an international standard for the calibration of liquid particle counters giving NIST

  9. Forward shower counters for diffractive physics at the LHC

    NASA Astrophysics Data System (ADS)

    Albrow, Michael; Collins, Paula; Penzo, Aldo

    2014-11-01

    The LHC detectors have incomplete angular coverage in the forward direction, for example in the region 6 ≲ |η| ≲ 8, which can be improved with the addition of simple scintillation counters around the beam pipes about 50 m to 120 m from the intersection point. These counters detect showers created by particles hitting the beam pipes and nearby material. The absence of signals in these counters in low pileup conditions is an indication of a forward rapidity gap as a signature of diffraction. In addition, they can be used to detect hadrons from low mass diffractive excitations of the proton, not accompanied by a leading proton but adjacent to a rapidity gap over (e.g.) 3 ≲ |η| ≲ 6. Such a set of forward shower counters, originally used at CDF, was used in CMS (FSC) for high-β* running with TOTEM during LHC Run-1. During LS1 the CMS FSC system is being upgraded for future low pileup runs. A similar system, called HERSCHEL is being installed in LHCb. ALICE is implementing scintillation counters, ADA and ADC, with 4.5 ≲ |η| ≲ 6.4.

  10. Implementation strategies to promote community-engaged efforts to counter tobacco marketing at the point of sale.

    PubMed

    Leeman, Jennifer; Myers, Allison; Grant, Jennifer C; Wangen, Mary; Queen, Tara L

    2017-09-01

    The US tobacco industry spends $8.2 billion annually on marketing at the point of sale (POS), a practice known to increase tobacco use. Evidence-based policy interventions (EBPIs) are available to reduce exposure to POS marketing, and nationwide, states are funding community-based tobacco control partnerships to promote local enactment of these EBPIs. Little is known, however, about what implementation strategies best support community partnerships' success enacting EBPI. Guided by Kingdon's theory of policy change, Counter Tools provides tools, training, and other implementation strategies to support community partnerships' performance of five core policy change processes: document local problem, formulate policy solutions, engage partners, raise awareness of problems and solutions, and persuade decision makers to enact new policy. We assessed Counter Tools' impact at 1 year on (1) partnership coordinators' self-efficacy, (2) partnerships' performance of core policy change processes, (3) community progress toward EBPI enactment, and (4) salient contextual factors. Counter Tools provided implementation strategies to 30 partnerships. Data on self-efficacy were collected using a pre-post survey. Structured interviews assessed performance of core policy change processes. Data also were collected on progress toward EBPI enactment and contextual factors. Analysis included descriptive and bivariate statistics and content analysis. Following 1-year exposure to implementation strategies, coordinators' self-efficacy increased significantly. Partnerships completed the greatest proportion of activities within the "engage partners" and "document local problem" core processes. Communities made only limited progress toward policy enactment. Findings can inform delivery of implementation strategies and tests of their effects on community-level efforts to enact EBPIs.

  11. 4-GHz counters bring synthesizers up to speed

    NASA Astrophysics Data System (ADS)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  12. 21 CFR 862.2320 - Beta or gamma counter for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Beta or gamma counter for clinical use. 862.2320... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2320 Beta or gamma counter for clinical use. (a) Identification. A beta or gamma counter for...

  13. Countering Internet Extremism

    DTIC Science & Technology

    2009-01-01

    early stages of the conflict, and secure an information warfare victory. Extremists’ use of the Internet has developed rapidly since the Chechen...activities Countering Internet Extremism By Mr. Timothy L. Thomas Editorial Abstract: The author examines the modern informational environment, and...spite of all of these resources—plus all of the money the west has thrown into information (read Internet ) security—an individual known as Irhabi

  14. Spiral counter-current chromatography: Design, development, application, and challenges.

    PubMed

    Huang, Xin-Yi; Sun, Xiao-Ming; Pei, Dong; Di, Duo-Long

    2017-01-01

    Depending on the rapid growth in the radial gradient of the centrifugal force, spiral counter-current chromatography can greatly improve the retention of stationary phase, especially for the aqueous two-phase systems with ultra-polar and high viscosity that are not well retained in the conventional multilayer coils counter-current chromatography. As a result, it is an attractive and alternative technology that is suited for separation of hydrophilic compounds and has led to many exciting progress in recent years. This review presents the recent advances and applications of spiral counter-current chromatography, including its major benefits and limitations, some novel methods to improve the separation efficiency and its applications in separation of real samples. In addition, the remaining challenges and future perspectives on development of spiral counter-current chromatography also are proposed in this article. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    PubMed

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  16. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    PubMed Central

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  17. Wingtip mounted, counter-rotating proprotor for tiltwing aircraft

    NASA Technical Reports Server (NTRS)

    Wechsler, James K. (Inventor); Rutherford, John W. (Inventor)

    1995-01-01

    A tiltwing aircraft, capable of in-flight conversion between a hover and forward cruise mode, employs a counter-rotating proprotor arrangement which permits a significantly increased cruise efficiency without sacrificing either the size of the conversion envelope or the wing efficiency. A benefit in hover is also provided because of the lower effective disk loading for the counter-rotating proprotor, as opposed to a single rotation proprotor of the same diameter. At least one proprotor is provided on each wing section, preferably mounted on the wingtip, with each proprotor having two counter-rotating blade rows. Each blade row has a plurality of blades which are relatively stiff-in-plane and are mounted such that cyclic pitch adjustments may be made for hover control during flight.

  18. User's manual for UCAP: Unified Counter-Rotation Aero-Acoustics Program

    NASA Technical Reports Server (NTRS)

    Culver, E. M.; Mccolgan, C. J.

    1993-01-01

    This is the user's manual for the Unified Counter-rotation Aeroacoustics Program (UCAP), the counter-rotation derivative of the UAAP (Unified Aero-Acoustic Program). The purpose of this program is to predict steady and unsteady air loading on the blades and the noise produced by a counter-rotation Prop-Fan. The aerodynamic method is based on linear potential theory with corrections for nonlinearity associated with axial flux induction, vortex lift on the blades, and rotor-to-rotor interference. The theory for acoustics and the theory for individual blade loading and wakes are derived in Unified Aeroacoustics Analysis for High Speed Turboprop Aerodynamics and Noise, Volume 1 (NASA CR-4329). This user's manual also includes a brief explanation of the theory used for the modelling of counter-rotation.

  19. User's manual for UCAP: Unified Counter-Rotation Aero-Acoustics Program

    NASA Astrophysics Data System (ADS)

    Culver, E. M.; McColgan, C. J.

    1993-04-01

    This is the user's manual for the Unified Counter-rotation Aeroacoustics Program (UCAP), the counter-rotation derivative of the UAAP (Unified Aero-Acoustic Program). The purpose of this program is to predict steady and unsteady air loading on the blades and the noise produced by a counter-rotation Prop-Fan. The aerodynamic method is based on linear potential theory with corrections for nonlinearity associated with axial flux induction, vortex lift on the blades, and rotor-to-rotor interference. The theory for acoustics and the theory for individual blade loading and wakes are derived in Unified Aeroacoustics Analysis for High Speed Turboprop Aerodynamics and Noise, Volume 1 (NASA CR-4329). This user's manual also includes a brief explanation of the theory used for the modelling of counter-rotation.

  20. Single-ended counter-rotating radial turbine for space application

    DOEpatents

    Coomes, E.P.; Wilson, D.G.; Webb, B.J.; McCabe, S.J.

    1987-05-13

    A single-ended turbine with counter-rotating blades operating with sodium as the working fluid. The single-ended, counter-rotating feature of the turbine results in zero torque application to a space platform. Thus, maneuvering of the platform is not adversely affected by the turbine. 4 figs.

  1. Kelvin-Helmholtz instability of counter-rotating discs

    NASA Astrophysics Data System (ADS)

    Quach, Dan; Dyda, Sergei; Lovelace, Richard V. E.

    2015-01-01

    Observations of galaxies and models of accreting systems point to the occurrence of counter-rotating discs where the inner part of the disc (r < r0) is corotating and the outer part is counter-rotating. This work analyses the linear stability of radially separated co- and counter-rotating thin discs. The strong instability found is the supersonic Kelvin-Helmholtz instability. The growth rates are of the order of or larger than the angular rotation rate at the interface. The instability is absent if there is no vertical dependence of the perturbation. That is, the instability is essentially three dimensional. The non-linear evolution of the instability is predicted to lead to a mixing of the two components, strong heating of the mixed gas, and vertical expansion of the gas, and annihilation of the angular momenta of the two components. As a result, the heated gas will free-fall towards the disc's centre over the surface of the inner disc.

  2. Dark state with counter-rotating dissipative channels.

    PubMed

    Zhou, Zheng-Yang; Chen, Mi; Wu, Lian-Ao; Yu, Ting; You, J Q

    2017-07-24

    Dark state as a consequence of interference between different quantum states has great importance in the fields of chip-scale atomic clock and quantum information. For the Λ-type three-level system, this dark state is generally regarded as being dissipation-free because it is a superposition of two lowest states without dipole transition between them. However, previous studies are based on the rotating-wave approximation (RWA) by neglecting the counter-rotating terms in the system-environment interaction. In this work, we study non-Markovian quantum dynamics of the dark state in a Λ-type three-level system coupled to two bosonic baths and reveal the effect of counter-rotating terms on the dark state. In contrast to the dark state within the RWA, leakage of the dark state occurs even at zero temperature, as a result of these counter-rotating terms. Also, we present a method to restore the quantum coherence of the dark state by applying a leakage elimination operator to the system.

  3. Observations of interference between portable particle counters and NOx monitors

    NASA Astrophysics Data System (ADS)

    Bereznicki, Sarah D.; Kamal, Ali

    2013-08-01

    Studies in environmental exposure science have developed a preference for smaller devices that can be easily co-located without need for gas standards, such as those instruments utilized in the Near-road Exposures and Effects from Urban Air Pollutants Study (NEXUS). One observation from NEXUS was the potential for instrument interference from alcohol-based particle counters on photometric-based nitrogen oxide (NOx) monitors. This article reports the findings from laboratory tests replicating enclosed-shelter monitoring configurations and operation cycles for a common photometric-based NOx monitor and a widely used alcohol-based particle counter. These tests monitored the NOx response while the particle counter sampling interval and ambient airflow rate were varied to (1) confirm that proximity between the instruments induced interferences, (2) identify any dependencies in NOx monitor recovery on ambient airflow, and (3) determine the time needed for the NOx monitor to recover to pre-interference levels under different atmospheric conditions. During particle counter operations, NOx concentrations responded instantaneously with a several-fold jump above the measurement baseline. When the particle counter was operated for more than 10 min, this interference period also showed a marked decline in the NOx baseline. The overall recovery time of the NOx monitor depended less on the time of particle counter operation, and more on the speed of ambient airflow. If photometric-based NOx monitors need to be operated alongside alcohol-based particle counters, mechanisms must be employed to exhaust alcohol-based vapors from enclosed monitoring environments. Given the strong evidence for interference, however, it is recommended these devices not be operated within close proximity to one another.

  4. Effect on smoking cessation of switching nicotine replacement therapy to over-the-counter status.

    PubMed

    Thorndike, Anne N; Biener, Lois; Rigotti, Nancy A

    2002-03-01

    This study examined whether the change in nicotine replacement therapy sales from prescription to over the counter (OTC) status affected smoking cessation. We used the 1993-1999 Massachusetts Tobacco Surveys to compare data from adult current smokers and recent quitters before and after the OTC switch. No significant change over time occurred in the proportion of smokers who used nicotine replacement therapy at a quit attempt in the past year (20.1% pre-OTC vs 21.4% post-OTC), made a quit attempt in the past year (48.1% vs 45.2%), or quit smoking in the past year (8.1% vs 11.1%). Fewer non-Whites used nicotine replacement therapy after the switch (20.7% pre-OTC vs 3.2% post-OTC, P =.002), but the proportion of Whites using nicotine replacement therapy did not change significantly (20.6% vs 24.0%). We observed no increase in Massachusetts smokers' rates of using nicotine replacement therapy, making a quit attempt, or stopping smoking after nicotine replacement therapy became available for OTC sale. There appear to be other barriers to the use of nicotine replacement therapy besides visiting a physician, especially among minority smokers.

  5. Prescription Drugs, Over-the-Counter Drugs, Supplements and Herbal Products

    MedlinePlus

    ... at risk? Zika virus and pregnancy Folic acid Medicine safety and pregnancy Birth defects prevention Learn how ... the-counter drugs, supplements and herbal products Prescription drugs, over-the-counter drugs, supplements and herbal products ...

  6. DMA shared byte counters in a parallel computer

    DOEpatents

    Chen, Dong; Gara, Alan G.; Heidelberger, Philip; Vranas, Pavlos

    2010-04-06

    A parallel computer system is constructed as a network of interconnected compute nodes. Each of the compute nodes includes at least one processor, a memory and a DMA engine. The DMA engine includes a processor interface for interfacing with the at least one processor, DMA logic, a memory interface for interfacing with the memory, a DMA network interface for interfacing with the network, injection and reception byte counters, injection and reception FIFO metadata, and status registers and control registers. The injection FIFOs maintain memory locations of the injection FIFO metadata memory locations including its current head and tail, and the reception FIFOs maintain the reception FIFO metadata memory locations including its current head and tail. The injection byte counters and reception byte counters may be shared between messages.

  7. Alcohol counter-advertising and the media. A review of recent research.

    PubMed

    Agostinelli, Gina; Grube, Joel W

    2002-01-01

    Counter-advertising commonly is used to balance the effects that alcohol advertising may have on alcohol consumption and alcohol-related problems. Such measures can take the form of print or broadcast advertisements (e.g., public service announcements [PSAs]) as well as product warning labels. The effectiveness of both types of counter-advertising is reviewed using the Elaboration Likelihood Model as a theoretical framework. For print and broadcast counter-advertisements, such factors as their emotional appeal and the credibility of the source, as well as audience factors, can influence their effectiveness. Further, brewer-sponsored counter-advertisements are evaluated and received differently than are the more conventional PSA counter-advertisements. For warning labels, both the content and design of the label influence their effectiveness, as do audience factors. The effectiveness of those labels is evaluated in terms of the extent to which they impact cognitive and affective processes as well as drinking behavior.

  8. Hardware support for collecting performance counters directly to memory

    DOEpatents

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  9. Over the Counter & Complementary Therapies

    MedlinePlus

    ... a Parkinson’s Foundation Center of Excellence. 0 ‹ Medical Marijuana up Exercise › Sample Title of Item (also a link) Treatment Prescription Medications Surgical Treatment Options Medical Marijuana Over the Counter & Complementary Therapies Exercise Clinical Trials ...

  10. Workplace Violence in Early Childhood Settings: A Counter Narrative.

    ERIC Educational Resources Information Center

    Sumsion, Jennifer

    Noting that portrayals of early childhood settings as communities of care distinguish them from other education contexts, this paper presents a counter-narrative that focuses on workplace tensions experienced by an Australian preschool teacher. The counter-narrative was informed by informal interviews held 4 times yearly over a period of 7 years…

  11. Counter-transference reactions contributing to completed suicide.

    PubMed

    Modestin, J

    1987-12-01

    Counter-transference reactions are frequently elicited while treating suicidal patients and they may contribute to the patient's committing suicide. Therapeutic constellations including the failure of the therapist to (1) cope with the patient's aggressiveness, (2) tolerate the patient's dependency, (3) handle the erotic transference adequately and (4) preserve loyalty towards the patient; they have all been identified as being responsible for a therapeutic impasse with fatal consequences. Knowledge of the therapeutic constellations especially prone to facilitate negative counter-transference reactions may help the therapist to master them effectively.

  12. Message passing with a limited number of DMA byte counters

    DOEpatents

    Blocksome, Michael [Rochester, MN; Chen, Dong [Croton on Hudson, NY; Giampapa, Mark E [Irvington, NY; Heidelberger, Philip [Cortlandt Manor, NY; Kumar, Sameer [White Plains, NY; Parker, Jeffrey J [Rochester, MN

    2011-10-04

    A method for passing messages in a parallel computer system constructed as a plurality of compute nodes interconnected as a network where each compute node includes a DMA engine but includes only a limited number of byte counters for tracking a number of bytes that are sent or received by the DMA engine, where the byte counters may be used in shared counter or exclusive counter modes of operation. The method includes using rendezvous protocol, a source compute node deterministically sending a request to send (RTS) message with a single RTS descriptor using an exclusive injection counter to track both the RTS message and message data to be sent in association with the RTS message, to a destination compute node such that the RTS descriptor indicates to the destination compute node that the message data will be adaptively routed to the destination node. Using one DMA FIFO at the source compute node, the RTS descriptors are maintained for rendezvous messages destined for the destination compute node to ensure proper message data ordering thereat. Using a reception counter at a DMA engine, the destination compute node tracks reception of the RTS and associated message data and sends a clear to send (CTS) message to the source node in a rendezvous protocol form of a remote get to accept the RTS message and message data and processing the remote get (CTS) by the source compute node DMA engine to provide the message data to be sent.

  13. Slim by Design: Kitchen Counter Correlates of Obesity.

    PubMed

    Wansink, Brian; Hanks, Andrew S; Kaipainen, Kirsikka

    2016-10-01

    Background The home is one place where people can control what foods are available and how the environment is arranged. Given the impact of environments on health, the objective of this study is to determine whether the presence of foods on a person's kitchen counter are associated with their body mass index (BMI). Method In Study 1, a nationwide sample of 500 households was asked to inventory their kitchen and provide their height and weight. In Study 2, researchers photographed and catalogued 210 households in Syracuse, New York, and measured the occupants' height and weight. Main outcome measures for the study were BMI differences between households that had various foods visible on the counter compared with those that did not. Findings The presence of fruit on the counter was associated with lower BMI in both studies, but the presence of foods such as candy, cereal, soft drinks, and dried fruit were associated with weight differences that ranged from 9.4 to 14.4 kg. Interpretations Although correlational, the findings from these two studies suggest that when counseling patients regarding their weight, physicians also suggest they clear their kitchen counter of all food except a fruit bowl. © 2015 Society for Public Health Education.

  14. Minimizing losses by variational counter-diabatic driving

    NASA Astrophysics Data System (ADS)

    Sels, Dries; Polkovnikov, Anatoli

    Despite the time-reversal symmetry of the microscopic dynamics of isolated systems, losses are ubiquitous in any process that tries to manipulate them. Whether it's the heat produced in a car engine or the decoherence of a qubit, all losses arise from our lack of control on the microscopic degrees of freedom of the system. Counter-diabatic driving protocols were proposed as a means to do fast changes in the Hamiltonian without exciting transitions. Such driving in principle allows one to realize arbitrarily fast annealing protocols or implement fast dissipationless driving, circumventing standard adiabatic limitations requiring infinitesimally slow rates. These ideas were tested and used both experimentally and theoretically in small systems, but in larger chaotic systems it is known that exact counter-diabatic protocols do not exist. Here we will present a simple variational approach allowing one to find best physical counter-diabatic protocols. We will show that, while they do not get rid of all transitions, the variational protocols are able to significantly reduce the induced fluctuations in the system. D.S. acknowledges support by the FWO.

  15. Norms in Conflict: Statecraft, Preventive Force, and Counter Proliferation

    DTIC Science & Technology

    2016-12-01

    power. Finally, the ethical character of norms offers a framework for the attacking state to justify its actions to the international community ...national identity, sanctions, and ethics play in counter-proliferation strategies. Finally, it concludes by offering policy recommendations for...role that national identity, sanctions, and ethics play in counter-proliferation strategies. Finally, it concludes by offering policy

  16. Analyzing the Operational Factors of Space, Force, and Time in United States Southern Command’s Counter Drug / Counter Narcoterrorism Mission

    DTIC Science & Technology

    2010-05-03

    countries by the President. Of the 20 nations listed as meeting the criteria for 2008, 12 are found in SOUTHCOM’s AOR: The Bahamas, Bolivia , Brazil...Venezuela and Bolivia ), making them harder to catch on their way to Mexico or, increasingly, overseas.” 26 (Italics added for emphasis) Beyond pure...Southern Command. Command Strategy 2018 . Miami, FL: December, 2008. ------. “Counter Drug / Counter Narcoterrorism.” www.southcom.mil/AppsSC/pages

  17. Electronic strain-level counter

    NASA Technical Reports Server (NTRS)

    Pitts, F. L.; Spencer, J. L. (Inventor)

    1973-01-01

    An electronic strain level counter for obtaining structural strain data on in-flight aircraft is described. The device counts the number of times the strain at a point on an aircraft structural member exceeds each of several preset levels. A dead band is provided at each level to prohibit the counting of small strain variations around a given preset level.

  18. Over-the-counter and prescription sleep medication and incident stroke: the REasons for Geographic and Racial Differences in Stroke study.

    PubMed

    Petrov, Megan E; Howard, Virginia J; Kleindorfer, Dawn; Grandner, Michael A; Molano, Jennifer R; Howard, George

    2014-09-01

    Preliminary evidence suggests sleep medications are associated with risk of vascular events; however, the long-term vascular consequences are understudied. This study investigated the relation between sleep medication use and incident stroke. Within the REasons for Geographic And Racial Differences in Stroke study, 21,678 black participants and white participants (≥45 years) with no history of stroke were studied. Participants were recruited from 2003 to 2007. From 2008 to 2010, participants self reported their prescription and over-the-counter sleep medication use over the past month. Suspected stroke events were identified by telephone contact at 6-month intervals and associated medical records were retrieved and physician-adjudicated. Proportional hazards analysis was used to estimate hazard ratios for incident stroke associated with sleep medication use (0, 1-14, and 15+ days per month) controlling for sociodemographics, stroke risk factors, mental health symptoms, and sleep apnea risk. At the sleep assessment, 9.6% of the sample used prescription sleep medication and 11.1% used over-the-counter sleep aids. Over an average follow-up of 3.3 ± 1.0 years, 297 stroke events occurred. Over-the-counter sleep medication use was associated with increased risk of incident stroke in a frequency-response relationship (P = .014), with a 46% increased risk for 1-14 days of use per month (hazards ratio [HR] = 1.46; 95% confidence interval [CI], .99-2.15) and a 65% increased risk for 15+ days (HR = 1.65; 95% CI, .96-2.85). There was no significant association with prescription sleep medications (P = .80). Over-the-counter sleep medication use may independently increase the risk of stroke beyond other risk factors in middle-aged to older individuals with no history of stroke. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  19. Development of a high-sensitivity BGO well counter for small animal PET studies.

    PubMed

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun

    2012-01-01

    In quantitative measurements of small animal PET studies, blood sampling is limited due to the small amounts of blood such animals can provide. In addition, injection doses are quite limited. In this situation, a high-sensitivity well counter would be useful for reducing the amount of the blood sample needed from small animals. Bismuth germinate (BGO) has a high stopping power for high-energy gamma rays compared to NaI(Tl), which is commonly used for conventional well counters. We have developed a BGO well counter and have tested it for blood-sampling measurements in small animals. The BGO well counter uses a square BGO block (59 × 59 × 50 mm) with a square open space (27 × 27 × 34 mm) in the center of the block. The BGO block was optically coupled to a 59-mm square-shaped photomultiplier tube (PMT). Signals from the PMT were digitally processed for the integration and energy window setting. The results showed that the energy spectrum of the BGO well counter measured with a Na-22 point source provided counts that were about 6 times higher for a 1022-keV (511 keV × 2) gamma peak than the spectrum of a 2-in. NaI(Tl) well counter. The relative sensitivity of the developed BGO well counter was 3.4 times higher than that of a NaI(Tl) well counter. The time activity curve of arterial blood was obtained successfully with the BGO well counter for a F-18-FDG study on rat. The BGO well counter will contribute to reducing the amount of sampled blood and to improving the throughput of quantitative measurements in small animal PET studies.

  20. Swarm Counter-Asymmetric-Threat (CAT) 6-DOF Dynamics Simulation

    DTIC Science & Technology

    2005-07-01

    NAWCWD TP 8593 Swarm Counter-Asymmetric-Threat ( CAT ) 6-DOF Dynamics Simulation by James Bobinchak Weapons and Energetics...mathematical models used in the swarm counter- asymmetric-threat ( CAT ) simulation and the results of extensive Monte Carlo simulations. The swarm CAT ...Asymmetric-Threat ( CAT ) 6-DOF Dynamics Simulation (U) 6. AUTHOR(S) James Bobinchak and Gary Hewer 7. PERFORMING ORGANIZATION NAME(S) AND

  1. Changing the status of drugs from prescription to over-the-counter availability.

    PubMed

    Brass, E P

    2001-09-13

    The availability of drugs on an over-the-counter basis, including those previously available only by prescription, provides patients with improved access to effective therapies. Removal of the requirement for prescriptions saves both the health care professional and the patient time. However, the overall effect on health care costs is complex. One such effect may be that costs shift from third-party payers to patients. In addition, short-term cost savings may be offset over the long term by problems due to inappropriate use or suboptimal therapy. Optimal therapy with an over-the-counter drug requires that the consumer diagnose the underlying condition correctly and use the drug in a manner that minimizes risk. Assessment of the ability of patients to use drugs in this manner is a critical component of the regulatory review of over-the-counter drugs. The available data arouse the concern that without the supervision of a health care professional, some patients may not be able to use over-the-counter drugs appropriately for certain diagnoses or chronic conditions or in high-risk situations. On the other hand, the widespread use of over-the-counter aspirin on a long-term basis for cardiovascular-risk reduction illustrates the potential value of increased drug availability for long-term therapy. Advances in technology may facilitate the growth of over-the-counter drug therapy. For example, the wide availability and acceptance of reliable methods for measuring serum cholesterol in nonmedical settings may eventually contribute to the safety and effectiveness of over-the-counter treatments for hyperlipidemia. Thus, the future promises increases in the number of drugs available over the counter and in the variety of indications for their use.

  2. Development and testing of 2-dimensional photon counter

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The development of a commercially available two dimensional photon counter into an operational system for speckle imaging of astronomical objects is described. The system includes digital recording for field observations. The counter has a bialkali photocathode with a field size of 18 by 18 mm over which it resolves about 100 by 100 pixels. The system records photon positions as 16 bit words at rates up to 14,400 per second. Field tests at observatories verifying the operation of the system are described.

  3. THz Hot-Electron Photon Counter

    NASA Technical Reports Server (NTRS)

    Karasik, Boris S.; Sergeev, Andrei V.

    2004-01-01

    We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

  4. Using Counter-Stories to Challenge Stock Stories about Traveller Families

    ERIC Educational Resources Information Center

    D'Arcy, Kate

    2017-01-01

    Critical Race Theory (CRT) is formed from a series of different methodological tools to expose and address racism and discrimination. Counter-stories are one of these tools. This article considers the potential of counter-stories as a methodological, theoretical and practical tool to analyse existing educational inequalities for Traveller…

  5. 78 FR 57623 - TRICARE Over-the-Counter Drug Demonstration Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... DEPARTMENT OF DEFENSE Office of the Secretary TRICARE Over-the-Counter Drug Demonstration Project AGENCY: Office of the Secretary, DoD. ACTION: Notice of modification to the TRICARE Over-the-Counter Drug...) drugs to be included on the TRICARE uniform formulary. The Department has been engaged in a...

  6. EFFECT OF CHERENKOV LIGHT POLARIZATION ON TOTAL REFLECTION COUNTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, J.D.; Duteil, P.; Leontic, B.

    1963-01-01

    A rugged total internal reflection counter with a 3- to 5cm thick compact radiator was used at the CERN proton synchrotron for beam analysis. The threshold behavior of this counter was compared when filled with glycerol and with turpentine. Turpentine is optically active and rotates the plane of polarization about 7 un. Concent 85% /cm. Figures illustrate the effect of this polarization rotation. (A.G.W.)

  7. An acoustical bubble counter for superheated drop detectors.

    PubMed

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  8. Effect on Smoking Cessation of Switching Nicotine Replacement Therapy to Over-the-Counter Status

    PubMed Central

    Thorndike, Anne N.; Biener, Lois; Rigotti, Nancy A.

    2002-01-01

    Objectives. This study examined whether the change in nicotine replacement therapy sales from prescription to over the counter (OTC) status affected smoking cessation. Methods. We used the 1993–1999 Massachusetts Tobacco Surveys to compare data from adult current smokers and recent quitters before and after the OTC switch. Results. No significant change over time occurred in the proportion of smokers who used nicotine replacement therapy at a quit attempt in the past year (20.1% pre-OTC vs 21.4% post-OTC), made a quit attempt in the past year (48.1% vs 45.2%), or quit smoking in the past year (8.1% vs 11.1%). Fewer non-Whites used nicotine replacement therapy after the switch (20.7% pre-OTC vs 3.2% post-OTC, P = .002), but the proportion of Whites using nicotine replacement therapy did not change significantly (20.6% vs 24.0%). Conclusions. We observed no increase in Massachusetts smokers' rates of using nicotine replacement therapy, making a quit attempt, or stopping smoking after nicotine replacement therapy became available for OTC sale. There appear to be other barriers to the use of nicotine replacement therapy besides visiting a physician, especially among minority smokers. (Am J Public Health. 2002;92:437–442) PMID:11867326

  9. Hardware enabled performance counters with support for operating system context switching

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2015-06-30

    A device for supporting hardware enabled performance counters with support for context switching include a plurality of performance counters operable to collect information associated with one or more computer system related activities, a first register operable to store a memory address, a second register operable to store a mode indication, and a state machine operable to read the second register and cause the plurality of performance counters to copy the information to memory area indicated by the memory address based on the mode indication.

  10. 49 CFR 219.103 - Prescribed and over-the-counter drugs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Prescribed and over-the-counter drugs. 219.103... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Prohibitions § 219.103 Prescribed and over-the-counter drugs. (a) This subpart does not prohibit the use of a controlled substance (on...

  11. 49 CFR 219.103 - Prescribed and over-the-counter drugs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Prescribed and over-the-counter drugs. 219.103... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Prohibitions § 219.103 Prescribed and over-the-counter drugs. (a) This subpart does not prohibit the use of a controlled substance (on...

  12. 49 CFR 219.103 - Prescribed and over-the-counter drugs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Prescribed and over-the-counter drugs. 219.103... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Prohibitions § 219.103 Prescribed and over-the-counter drugs. (a) This subpart does not prohibit the use of a controlled substance (on...

  13. 49 CFR 219.103 - Prescribed and over-the-counter drugs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Prescribed and over-the-counter drugs. 219.103... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Prohibitions § 219.103 Prescribed and over-the-counter drugs. (a) This subpart does not prohibit the use of a controlled substance (on...

  14. Using a PC as a Frequency Meter or a Counter.

    ERIC Educational Resources Information Center

    Sartori, J.; And Others

    1995-01-01

    Describes hardware that enables the use of an IBM PC microcomputer as a frequency meter or a counter by using the parallel printer port. Eliminates the 16-bit time-day counter through the use of an external time base that can be conveniently set depending on the desired frequency range. (JRH)

  15. Counter-Stereotypes and Images: An Exploratory Research and Some Questions

    ERIC Educational Resources Information Center

    Morin-Messabel, Christine; Ferrière, Séverine; Martinez, Frederic; Devif, Julie; Reeb, Laurence

    2017-01-01

    The dynamics of the construction and perpetuation of gender stereotypes are classic research subjects in social psychology and in the field of educational guidelines in France. The most recent government decree aims to counter stereotypes in schools, by exposing pupils to counter-stereotypes. This study examines the effects of activating…

  16. 49 CFR 219.103 - Prescribed and over-the-counter drugs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Prescribed and over-the-counter drugs. 219.103... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Prohibitions § 219.103 Prescribed and over-the-counter drugs. (a) This subpart does not prohibit the use of a controlled substance (on...

  17. Semi-automatic, octave-spanning optical frequency counter.

    PubMed

    Liu, Tze-An; Shu, Ren-Huei; Peng, Jin-Long

    2008-07-07

    This work presents and demonstrates a semi-automatic optical frequency counter with octave-spanning counting capability using two fiber laser combs operated at different repetition rates. Monochromators are utilized to provide an approximate frequency of the laser under measurement to determine the mode number difference between the two laser combs. The exact mode number of the beating comb line is obtained from the mode number difference and the measured beat frequencies. The entire measurement process, except the frequency stabilization of the laser combs and the optimization of the beat signal-to-noise ratio, is controlled by a computer running a semi-automatic optical frequency counter.

  18. Body proportions in children with Kabuki syndrome.

    PubMed

    Penders, Bas; Schott, Nina; Gerver, Willem-Jan M; Stumpel, Constance T R M

    2016-03-01

    Facial characteristics, short stature, and skeletal anomalies have been described for the clinical diagnosis of Kabuki Syndrome (KS) in children. However, no studies have investigated body proportions in KS. Knowledge of body proportions in KS may contribute to better insight into the growth pattern and characterization of this genetic disorder. Therefore we compared body proportions of children with KS to normally proportioned controls to investigate if atypical body proportions are part of this genetic disorder. This study was designed and conducted within the setting of the Maastricht University Medical Centre (MUMC+), the official Dutch expert center for Kabuki syndrome. We conducted a cross-sectional study in 32 children (11 children with KS and 21 controls). Body proportions were determined by means of photogrammetric anthropometry, measurements based on digital photography. Body proportions, quantified as body ratios, differ significantly in children with KS from normally proportioned children. Children with KS have larger heads and longer arms proportional to their trunks and have been found to have longer upper arms proportional to their tibia length and feet. Based on deviations in body proportions it was shown possible to discern children with KS from normally proportioned controls. © 2015 Wiley Periodicals, Inc.

  19. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    NASA Astrophysics Data System (ADS)

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  20. Analytical solution for the anisotropic Rabi model: effects of counter-rotating terms.

    PubMed

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-04

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  1. Multicultural Young Adult Literature as a Form of Counter-Storytelling

    ERIC Educational Resources Information Center

    Hughes-Hassell, Sandra

    2013-01-01

    Counter-storytelling is defined by critical race theory scholars as a method of telling the stories of those people whose experiences are not often told, including people of color, the poor, and members of the LGBTQ community. This article discusses multicultural young adult literature as a form of counter-storytelling, with an emphasis on how…

  2. Technology and benefits of aircraft counter rotation propellers

    NASA Technical Reports Server (NTRS)

    Strack, W. C.; Knip, G.; Weisbrich, A. L.; Godston, J.; Bradley, E.

    1981-01-01

    Results are reported of a NASA sponsored analytical investigation into the merits of advanced counter rotation propellers for Mach 0.80 commercial transport application. Propeller and gearbox performance, acoustics, vibration characteristics, weight, cost and maintenance requirements for a variety of design parameters and special features were considered. Fuel savings in the neighborhood of 8 percent relative to single rotation configurations are feasible through swirl recovery and lighter gearboxes. This is the net gain which includes a 5 percent acoustic treatment weight penalty to offset the broader frequency spectrum noise produced by counter rotation blading.

  3. Reevaluation of pollen quantitation by an automatic pollen counter.

    PubMed

    Muradil, Mutarifu; Okamoto, Yoshitaka; Yonekura, Syuji; Chazono, Hideaki; Hisamitsu, Minako; Horiguchi, Shigetoshi; Hanazawa, Toyoyuki; Takahashi, Yukie; Yokota, Kunihiko; Okumura, Satoshi

    2010-01-01

    Accurate and detailed pollen monitoring is useful for selection of medication and for allergen avoidance in patients with allergic rhinitis. Burkard and Durham pollen samplers are commonly used, but are labor and time intensive. In contrast, automatic pollen counters allow simple real-time pollen counting; however, these instruments have difficulty in distinguishing pollen from small nonpollen airborne particles. Misidentification and underestimation rates for an automatic pollen counter were examined to improve the accuracy of the pollen count. The characteristics of the automatic pollen counter were determined in a chamber study with exposure to cedar pollens or soil grains. The cedar pollen counts were monitored in 2006 and 2007, and compared with those from a Durham sampler. The pollen counts from the automatic counter showed a good correlation (r > 0.7) with those from the Durham sampler when pollen dispersal was high, but a poor correlation (r < 0.5) when pollen dispersal was low. The new correction method, which took into account the misidentification and underestimation, improved this correlation to r > 0.7 during the pollen season. The accuracy of automatic pollen counting can be improved using a correction to include rates of underestimation and misidentification in a particular geographical area.

  4. Gold leaf counter electrodes for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Shimada, Kazuhiro; Toyoda, Takeshi

    2018-03-01

    In this study, a gold leaf 100 nm thin film is used as the counter electrode in dye-sensitized solar cells. The traditional method of hammering gold foil to obtain a thin gold leaf, which requires only small amounts of gold, was employed. The gold leaf was then attached to the substrate using an adhesive to produce the gold electrode. The proposed approach for fabricating counter electrodes is demonstrated to be facile and cost-effective, as opposed to existing techniques. Compared with electrodes prepared with gold foil and sputtered gold, the gold leaf counter electrode demonstrates higher catalytic activity with a cobalt-complex electrolyte and higher cell efficiency. The origin of the improved performance was investigated by surface morphology examination (scanning electron microscopy), various electrochemical analyses (cyclic voltammetry, linear sweep voltammetry, and electrochemical impedance spectroscopy), and crystalline analysis (X-ray diffractometry).

  5. Tobacco counter-advertising: a review of the literature and a conceptual model for understanding effects.

    PubMed

    Agostinelli, Gina; Grube, Joel W

    2003-01-01

    The tobacco counter-advertising literature is reviewed as it relates to basic process questions concerning what makes counter-advertisements effective. Limitations in addressing (a) counter-advertisement content and the psychological mediators targeted, (b) counter-advertisement style and the affective reactions targeted, (c) prior smoking experience, and (d) other audience factors are enumerated. A theoretical model based on alcohol advertising research is presented to address those limitations. The model addresses the practical research question of predicting when tobacco counter-advertising will work by examining the independent influence of each of these enumerated factors, as well as how these factors operate in concert, qualifying each other. The model also addresses the process question of explaining how counter-advertising works by identifying affective and cognitive processes as mediators. By understanding the processes that underlie the qualified findings, one can better advise the designers of tobacco counter-advertisements how to be more effective.

  6. Using DMA for copying performance counter data to memory

    DOEpatents

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W

    2013-12-31

    A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance data.

  7. Modeling and simulation of a counter-rotating turbine system for underwater vehicles

    NASA Astrophysics Data System (ADS)

    Wang, Xinping; Dang, Jianjun

    2016-12-01

    The structure of a counter-rotating turbine of an underwater vehicle is designed by adding the counter-rotating second-stage turbine disk after the conventional single-stage turbine. The available kinetic energy and the absorption power of the auxiliary system are calculated at different working conditions, and the results show that the power of the main engine and auxiliary system at the counter-rotating turbine system matches well with each other. The experimental simulation of the lubricating oil loop, fuel loop, and seawater loop are completed right before the technology scheme of the counter-rotating turbine system is proposed. The simulation results indicate that the hydraulic transmission system can satisfy the requirements for an underwater vehicle running at a steady sailing or variable working conditions.

  8. Image counter-forensics based on feature injection

    NASA Astrophysics Data System (ADS)

    Iuliani, M.; Rossetto, S.; Bianchi, T.; De Rosa, Alessia; Piva, A.; Barni, M.

    2014-02-01

    Starting from the concept that many image forensic tools are based on the detection of some features revealing a particular aspect of the history of an image, in this work we model the counter-forensic attack as the injection of a specific fake feature pointing to the same history of an authentic reference image. We propose a general attack strategy that does not rely on a specific detector structure. Given a source image x and a target image y, the adversary processes x in the pixel domain producing an attacked image ~x, perceptually similar to x, whose feature f(~x) is as close as possible to f(y) computed on y. Our proposed counter-forensic attack consists in the constrained minimization of the feature distance Φ(z) =│ f(z) - f(y)│ through iterative methods based on gradient descent. To solve the intrinsic limit due to the numerical estimation of the gradient on large images, we propose the application of a feature decomposition process, that allows the problem to be reduced into many subproblems on the blocks the image is partitioned into. The proposed strategy has been tested by attacking three different features and its performance has been compared to state-of-the-art counter-forensic methods.

  9. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    PubMed Central

    Zhang, Guofeng; Zhu, Hanjie

    2015-01-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model. PMID:25736827

  10. Timecourse of mirror and counter-mirror effects measured with transcranial magnetic stimulation

    PubMed Central

    Cavallo, Andrea; Heyes, Cecilia; Becchio, Cristina; Bird, Geoffrey

    2014-01-01

    The human mirror system has been the subject of much research over the past two decades, but little is known about the timecourse of mirror responses. In addition, it is unclear whether mirror and counter-mirror effects follow the same timecourse. We used single-pulse transcranial magnetic stimulation to investigate the timecourse of mirror and counter-mirror responses in the human brain. Experiment 1 demonstrated that mirror responses can be measured from around 200 ms after observed action onset. Experiment 2 demonstrated significant effects of counter-mirror sensorimotor training at all timepoints at which a mirror response was found in Experiment 1 (i.e. from 200 ms onward), indicating that mirror and counter-mirror responses follow the same timecourse. By suggesting similarly direct routes for mirror and counter-mirror responses, these results support the associative account of mirror neuron origins whereby mirror responses arise as a result of correlated sensorimotor experience during development. More generally, they contribute to theorizing regarding mirror neuron function by providing some constraints on how quickly mirror responses can influence social cognition. PMID:23709352

  11. Counter-current acid leaching process for copper azole treated wood waste.

    PubMed

    Janin, Amélie; Riche, Pauline; Blais, Jean-François; Mercier, Guy; Cooper, Paul; Morris, Paul

    2012-09-01

    This study explores the performance of a counter-current leaching process (CCLP) for copper extraction from copper azole treated wood waste for recycling of wood and copper. The leaching process uses three acid leaching steps with 0.1 M H2SO4 at 75degrees C and 15% slurry density followed by three rinses with water. Copper is recovered from the leachate using electrodeposition at 5 amperes (A) for 75 min. Ten counter-current remediation cycles were completed achieving > or = 94% copper extraction from the wood during the 10 cycles; 80-90% of the copper was recovered from the extract solution by electrodeposition. The counter-current leaching process reduced acid consumption by 86% and effluent discharge volume was 12 times lower compared with the same process without use of counter-current leaching. However, the reuse of leachates from one leaching step to another released dissolved organic carbon and caused its build-up in the early cycles.

  12. Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

    NASA Astrophysics Data System (ADS)

    Cowles, Christian; Behling, Spencer; Baldez, Phoenix; Folsom, Micah; Kouzes, Richard; Kukharev, Vladislav; Lintereur, Azaree; Robinson, Sean; Siciliano, Edward; Stave, Sean; Valdez, Patrick

    2018-04-01

    The feasibility of a full-scale lithium fluoride zinc sulfide (LiF/ZnS) based neutron multiplicity counter has been demonstrated. The counter was constructed of modular neutron detecting stacks that each contain five sheets of LiF/ZnS interleaved between six sheets of wavelength shifting plastic with a photomultiplier tube on each end. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high-density polyethylene blocks in the corners to reflect high-energy neutrons and capture low-energy neutrons. The final system design was optimized via modeling and small-scale test. Measuring neutrons from a 252Cf source, the counter achieved a 36% neutron detection efficiency (ɛ) and an 11 . 7 μs neutron die-away time (τ) for a doubles figure-of-merit (ɛ2 / τ) of 109. This is the highest doubles figure-of-merit measured to-date for a 3He-free neutron multiplicity counter.

  13. Paid counter-advertising: proven strategy to combat tobacco use and promotion.

    PubMed

    Blum, A

    1994-01-01

    This article discusses the effectiveness of paid counter-advertising in combating tobacco use and promotion, the impact of the Fairness Doctrine, which mandated anticigarette television advertisements in the late 1960s, and reasons why the media today are reluctant to run antismoking advertisements. Although counter-advertisements can work very well, they should be image-based, rather than fact-based. Currently, tobacco companies promote a positive image of cigarette smoking and brand awareness. Most antismoking ads, however, tend to focus on the tobacco itself and its adverse effects on the smoker, rather than combating the images the cigarette ads promote. Urging counter-advertising to focus on the product, rather than to try to produce guilt in smokers, this article provides examples of paid counter-advertising strategies employed by Doctors Ought to Care to illustrate an image-based approach. Overall, the antismoking movement must guard against complacency and measure its success according to tobacco companies' declining revenues, rather than the number of public service advertisements in the media.

  14. Low-Cost Flexible Nano-Sulfide/Carbon Composite Counter Electrode for Quantum-Dot-Sensitized Solar Cell

    PubMed Central

    2010-01-01

    Cu2S nanocrystal particles were in situ deposited on graphite paper to prepare nano-sulfide/carbon composite counter electrode for CdS/CdSe quantum-dot-sensitized solar cell (QDSC). By optimization of deposition time, photovoltaic conversion efficiency up to 3.08% was obtained. In the meantime, this composite counter electrode was superior to the commonly used Pt, Au and carbon counter electrodes. Electrochemical impedance spectra further confirmed that low charge transfer resistance at counter electrode/electrolyte interface was responsible for this, implied the potential application of this composite counter electrode in high-efficiency QDSC. PMID:20672135

  15. Evaluating Middle Years Students' Proportional Reasoning

    ERIC Educational Resources Information Center

    Hilton, Annette; Dole, Shelley; Hilton, Geoff; Goos, Merrilyn; O'Brien, Mia

    2012-01-01

    Proportional reasoning is a key aspect of numeracy that is not always developed naturally by students. Understanding the types of proportional reasoning that students apply to different problem types is a useful first step to identifying ways to support teachers and students to develop proportional reasoning in the classroom. This paper describes…

  16. The Eros of Counter Education

    ERIC Educational Resources Information Center

    Luzon, Pinhas

    2016-01-01

    Erotic Counter Education (ECE) is the educational position of the late Ilan Gur-Ze'ev. In ECE Gur-Ze'ev combines two opposing positions in the philosophy of education, one teleological and anti-utopian, the other teleological and utopian. In light of this unique combination, I ask what mediates between these two poles and suggest that the answer…

  17. The cognitive costs of the counter-stereotypic: gender, emotion, and social presence.

    PubMed

    McCarty, Megan K; Kelly, Janice R; Williams, Kipling D

    2014-01-01

    We explored the concurrent and subsequent cognitive consequences of the experience of gender counter-stereotypic emotions. Participants experiencing gender counter-stereotypic emotions were expected to display less emotional expression and demonstrate poorer cognitive performance when in the public condition than when in the private condition. Seventy-one women and 66 men completed an anger- or sadness-inducing task privately or publicly. Participants completed two cognitive tasks: one during and one after the emotion-induction task. Participants exhibited poorer performance during and following gender counter-stereotypic emotions only in the public condition. Direct evidence for greater suppression of gender counter-stereotypic emotions in the public conditions was not obtained. These results suggest that the same public emotional events may be differentially cognitively depleting depending on one's gender, potentially contributing to the perpetuation of stereotypes.

  18. The Identification and Validation Process of Proportional Reasoning Attributes: An Application of a Proportional Reasoning Modeling Framework

    ERIC Educational Resources Information Center

    Tjoe, Hartono; de la Torre, Jimmy

    2014-01-01

    In this paper, we discuss the process of identifying and validating students' abilities to think proportionally. More specifically, we describe the methodology we used to identify these proportional reasoning attributes, beginning with the selection and review of relevant literature on proportional reasoning. We then continue with the…

  19. LOAC (Light Optical Particle Counter): a new small aerosol counter with particle characterization capabilities for surface and airborne measurements

    NASA Astrophysics Data System (ADS)

    Renard, Jean-Baptiste; Berthet, Gwenael; Jégou, Fabrice; Jeannot, Matthieu; Jourdain, Line; Dulac, François; Mallet, Marc; Dupont, Jean-Charles; Thaury, Claire; Tonnelier, Thierry; Verdier, Nicolas; Charpentier, Patrick

    2013-04-01

    The determination of the size distribution of tropospheric and stratospheric aerosols with conventional optical counters is difficult when different natures of particles are present (droplets, soot, mineral dust, secondary organic or mineral particles...). Also, a light and cheap aerosol counter that can be used at ground, onboard drones or launched under all kinds of atmospheric balloons can be very useful during specific events as volcanic plumes, desert dust transport or local pollution episodes. These goals can be achieved thanks to a new generation of aerosol counter, called LOAC (Light Optical Aerosol Counter). The instrument was developed in the frame of a cooperation between French scientific laboratories (CNRS), the Environnement-SA and MeteoModem companies and the French Space Agency (CNES). LOAC is a small optical particle counter/sizer of ~250 grams, having a low electrical power consumption. The measurements are conducted at two scattering angles. The first one, at 12°, is used to determine the aerosol particle concentrations in 19 size classes within a diameter range of 0.3-100 micrometerers. At such an angle close to forward scattering, the signal is much more intense and the measurements are the least sensitive to the particle nature. The second angle is at 60°, where the scattered light is strongly dependent on the particle refractive index and thus on the nature of the aerosols. The ratio of the measurements at the two angles is used to discriminate between the different types of particles dominating the nature of the aerosol particles in the different size classes. The sensor particularly discriminates wet or liquid particles, soil dust and soot. Since 2011, we have operated LOAC in various environments (Arctic, Mediterranean, urban and peri-urban…) under different kinds of balloons including zero pressure stratospheric, tethered, drifting tropospheric, and meteorological sounding balloons. For the last case, the total weight of the gondola

  20. Optical fusions and proportional syntheses

    NASA Astrophysics Data System (ADS)

    Albert-Vanel, Michel

    2002-06-01

    A tragic error is being made in the literature concerning matters of color when dealing with optical fusions. They are still considered to be of additive nature, whereas experience shows us somewhat different results. The goal of this presentation is to show that fusions are, in fact, of 'proportional' nature, tending to be additive or subtractive, depending on each individual case. Using the pointillist paintings done in the manner of Seurat, or the spinning discs experiment could highlight this intermediate sector of the proportional. So, let us try to examine more closely what occurs in fact, by reviewing additive, subtractive and proportional syntheses.

  1. Analysis of counter flow of corona wind for heat transfer enhancement

    NASA Astrophysics Data System (ADS)

    Shin, Dong Ho; Baek, Soo Hong; Ko, Han Seo

    2018-03-01

    A heat sink for cooling devices using the counter flow of a corona wind was developed in this study. Detailed information about the numerical investigations of forced convection using the corona wind was presented. The fins of the heat sink using the counter flow of a corona wind were also investigated. The corona wind generator with a wire-to-plate electrode arrangement was used for generating the counter flow to the fin. The compact and simple geometric characteristics of the corona wind generator facilitate the application of the heat sink using the counter flow, demonstrating the heat sink is effective for cooling electronic devices. Parametric studies were performed to analyze the effect of the counter flow on the fins. Also, the velocity and temperature were measured experimentally for the test mock-up of the heat sink with the corona wind generator to verify the numerical results. From a numerical study, the type of fin and its optimal height, length, and pitch were suggested for various heat fluxes. In addition, the correlations to calculate the mass of the developed heat sink and its cooling performance in terms of the heat transfer coefficient were derived. Finally, the cooling efficiencies corresponding to the mass, applied power, total size, and noise of the devices were compared with the existing commercial central processing unit (CPU) cooling devices with rotor fans. As a result, it was confirmed that the heat sink using the counter flow of the corona wind showed appropriate efficiencies for cooling electronic devices, and is a suitable replacement for the existing cooling device for high power electronics.

  2. Counter-current convection in a volcanic conduit

    NASA Astrophysics Data System (ADS)

    Fowler, A. C.; Robinson, Marguerite

    2018-05-01

    Volcanoes of Strombolian type are able to maintain their semi-permanent eruptive states through the constant convective recycling of magma within the conduit leading from the magma chamber. In this paper we study the form of this convection using an analytic model of degassing two-phase flow in a vertical channel. We provide solutions for the flow at small Grashof and large Prandtl numbers, and we suggest that permanent steady-state counter-current convection is only possible if an initial bubbly counter-current flow undergoes a régime transition to a churn-turbulent flow. We also suggest that the magma in the chamber must be under-pressured in order for the flow to be maintained, and that this compromises the assumed form of the flow.

  3. Analysis of Broadband Metamaterial Shielding for Counter-Directed Energy Weapons

    DTIC Science & Technology

    2017-06-01

    SHIELDING FOR COUNTER-DIRECTED ENERGY WEAPONS by Chester H. Hewitt III June 2017 Thesis Advisor: Dragoslav Grbovic Second Reader: James H...COVERED Master’s thesis 4. TITLE AND SUBTITLE ANALYSIS OF BROADBAND METAMATERIAL SHIELDING FOR COUNTER-DIRECTED ENERGY WEAPONS 5. FUNDING NUMBERS 6...high-power microwave (HPM) directed- energy weapons (DEWs), which can disrupt electronics remotely with great accuracy without the need to inflict

  4. Reliability of Metrics Associated with a Counter-Movement Jump Performed on a Force Plate

    ERIC Educational Resources Information Center

    Lombard, Wayne; Reid, Sorrel; Pearson, Keagan; Lambert, Michael

    2017-01-01

    The counter-movement jump is a consequence of maximal force, rate of force developed, and neuromuscular coordination. Thus, the counter-movement jump has been used to monitor various training adaptations. However, the smallest detectable difference of counter-movement jump metrics has yet to be established. The objective of the present study was…

  5. Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown.

    PubMed

    Lum, Cynthia; Kennedy, Leslie W; Sherley, Alison

    2008-02-01

    Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown. One of the central concerns surrounding counter-terrorism interventions today, given the attention and money spent on them, is whether such interventions are effective. To explore this issue, we conducted a general review of terrorism literature as well as a Campbell systematic review on counter-terrorism strategies. In this article, we summarize some of our findings from these works. Overall, we found an almost complete absence of evaluation research on counter-terrorism strategies and conclude that counter-terrorism policy is not evidence-based. The findings of this review emphasise the need for government leaders, policy makers, researchers, and funding agencies to include and insist on evaluations of the effectiveness of these programs in their agendas.

  6. Timecourse of mirror and counter-mirror effects measured with transcranial magnetic stimulation.

    PubMed

    Cavallo, Andrea; Heyes, Cecilia; Becchio, Cristina; Bird, Geoffrey; Catmur, Caroline

    2014-08-01

    The human mirror system has been the subject of much research over the past two decades, but little is known about the timecourse of mirror responses. In addition, it is unclear whether mirror and counter-mirror effects follow the same timecourse. We used single-pulse transcranial magnetic stimulation to investigate the timecourse of mirror and counter-mirror responses in the human brain. Experiment 1 demonstrated that mirror responses can be measured from around 200 ms after observed action onset. Experiment 2 demonstrated significant effects of counter-mirror sensorimotor training at all timepoints at which a mirror response was found in Experiment 1 (i.e. from 200 ms onward), indicating that mirror and counter-mirror responses follow the same timecourse. By suggesting similarly direct routes for mirror and counter-mirror responses, these results support the associative account of mirror neuron origins whereby mirror responses arise as a result of correlated sensorimotor experience during development. More generally, they contribute to theorizing regarding mirror neuron function by providing some constraints on how quickly mirror responses can influence social cognition. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  7. Proportional Reasoning of Preservice Elementary Education Majors: An Epistemic Model of the Proportional Reasoning Construct.

    ERIC Educational Resources Information Center

    Fleener, M. Jayne

    Current research and learning theory suggest that a hierarchy of proportional reasoning exists that can be tested. Using G. Vergnaud's four complexity variables (structure, content, numerical characteristics, and presentation) and T. E. Kieren's model of rational number knowledge building, an epistemic model of proportional reasoning was…

  8. 21 CFR 201.315 - Over-the-counter drugs for minor sore throats; suggested warning.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Over-the-counter drugs for minor sore throats... Drug Products § 201.315 Over-the-counter drugs for minor sore throats; suggested warning. The Food and... counter for the relief of minor irritations of the mouth or throat. It will not object to the labeling of...

  9. 21 CFR 201.315 - Over-the-counter drugs for minor sore throats; suggested warning.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Over-the-counter drugs for minor sore throats... Drug Products § 201.315 Over-the-counter drugs for minor sore throats; suggested warning. The Food and... counter for the relief of minor irritations of the mouth or throat. It will not object to the labeling of...

  10. Impossibility Theorem in Proportional Representation Problem

    NASA Astrophysics Data System (ADS)

    Karpov, Alexander

    2010-09-01

    The study examines general axiomatics of Balinski and Young and analyzes existed proportional representation methods using this approach. The second part of the paper provides new axiomatics based on rational choice models. New system of axioms is applied to study known proportional representation systems. It is shown that there is no proportional representation method satisfying a minimal set of the axioms (monotonicity and neutrality).

  11. Proportional Reasoning as Essential Numeracy

    ERIC Educational Resources Information Center

    Dole, Shelley; Hilton, Annette; Hilton, Geoff

    2015-01-01

    This paper reports an aspect of a large research and development project that aimed to promote middle years school teachers' understanding and awareness of the pervasiveness of proportional reasoning as integral to numeracy. Teacher survey data of proportional reasoning across the curriculum were mapped on to a rich model of numeracy. Results…

  12. Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cowles, Christian; Behling, Spencer; Baldez, Phoenix

    Here, the feasibility of a full-scale lithium fluoride zinc sulfide (LiF/ZnS) based neutron multiplicity counter has been demonstrated. The counter was constructed of modular neutron detecting stacks that each contain five sheets of LiF/ZnS interleaved between six sheets of wavelength shifting plastic with a photomultiplier tube on each end. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high-density polyethylene blocks in the corners to reflect high-energy neutrons and capture low-energy neutrons. The final system design was optimized via modeling and small-scale test. Measuring neutrons from a 252Cf source, the counter achieved amore » 36% neutron detection efficiency (ϵϵ) and an View the MathML source11.7μs neutron die-away time (ττ) for a doubles figure-of-merit (ϵ 2/τ) of 109. This is the highest doubles figure-of-merit measured to-date for a 3He-free neutron multiplicity counter.« less

  13. Low-speed wind-tunnel tests of single- and counter-rotation propellers

    NASA Technical Reports Server (NTRS)

    Dunham, D. M.; Gentry, G. L., Jr.; Coe, P. L., Jr.

    1986-01-01

    A low-speed (Mach 0 to 0.3) wind-tunnel investigation was conducted to determine the basic performance, force and moment characteristics, and flow-field velocities of single- and counter-rotation propellers. Compared with the eight-blade single-rotation propeller, a four- by four- (4 x 4) blade counter-rotation propeller with the same blade design produced substantially higher thrust coefficients for the same blade angles and advance ratios. The results further indicated that ingestion of the wake from a supporting pylon for a pusher configuration produced no significant change in the propeller thrust performance for either the single- or counter-rotation propellers. A two-component laser velocimeter (LV) system was used to make detailed measurements of the propeller flow fields. Results show increasing slipstream velocities with increasing blade angle and decreasing advance ratio. Flow-field measurements for the counter-rotation propeller show that the rear propeller turned the flow in the opposite direction from the front propeller and, therefore, could eliminate the swirl component of velocity, as would be expected.

  14. Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

    DOE PAGES

    Cowles, Christian; Behling, Spencer; Baldez, Phoenix; ...

    2018-01-12

    Here, the feasibility of a full-scale lithium fluoride zinc sulfide (LiF/ZnS) based neutron multiplicity counter has been demonstrated. The counter was constructed of modular neutron detecting stacks that each contain five sheets of LiF/ZnS interleaved between six sheets of wavelength shifting plastic with a photomultiplier tube on each end. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high-density polyethylene blocks in the corners to reflect high-energy neutrons and capture low-energy neutrons. The final system design was optimized via modeling and small-scale test. Measuring neutrons from a 252Cf source, the counter achieved amore » 36% neutron detection efficiency (ϵϵ) and an View the MathML source11.7μs neutron die-away time (ττ) for a doubles figure-of-merit (ϵ 2/τ) of 109. This is the highest doubles figure-of-merit measured to-date for a 3He-free neutron multiplicity counter.« less

  15. Finding Feasible Abstract Counter-Examples

    NASA Technical Reports Server (NTRS)

    Pasareanu, Corina S.; Dwyer, Matthew B.; Visser, Willem; Clancy, Daniel (Technical Monitor)

    2002-01-01

    A strength of model checking is its ability to automate the detection of subtle system errors and produce traces that exhibit those errors. Given the high computational cost of model checking most researchers advocate the use of aggressive property-preserving abstractions. Unfortunately, the more aggressively a system is abstracted the more infeasible behavior it will have. Thus, while abstraction enables efficient model checking it also threatens the usefulness of model checking as a defect detection tool, since it may be difficult to determine whether a counter-example is feasible and hence worth developer time to analyze. We have explored several strategies for addressing this problem by extending an explicit-state model checker, Java PathFinder (JPF), to search for and analyze counter-examples in the presence of abstractions. We demonstrate that these techniques effectively preserve the defect detection ability of model checking in the presence of aggressive abstraction by applying them to check properties of several abstracted multi-threaded Java programs. These new capabilities are not specific to JPF and can be easily adapted to other model checking frameworks; we describe how this was done for the Bandera toolset.

  16. The effects of gender stereotypic and counter-stereotypic textbook images on science performance.

    PubMed

    Good, Jessica J; Woodzicka, Julie A; Wingfield, Lylan C

    2010-01-01

    We investigated the effect of gender stereotypic and counter-stereotypic images on male and female high school students' science comprehension and anxiety. We predicted stereotypic images to induce stereotype threat in females and impair science performance. Counter-stereotypic images were predicted to alleviate threat and enhance female performance. Students read one of three chemistry lessons, each containing the same text, with photograph content varied according to stereotype condition. Participants then completed a comprehension test and anxiety measure. Results indicate that female students had higher comprehension after viewing counter-stereotypic images (female scientists) than after viewing stereotypic images (male scientists). Male students had higher comprehension after viewing stereotypic images than after viewing counter-stereotypic images. Implications for alleviating the gender gap in science achievement are discussed.

  17. Informational and symbolic content of over-the-counter drug advertising on television.

    PubMed

    Tsao, J C

    1997-01-01

    The informational and symbolic content of 150 over-the-counter drug commercials on television are empirically analyzed in this study. Results on the informational content suggest that over-the-counter drug ads tend to focus on the concern of what the drug will do for the consumer, rather than on the reasons why the drug should be ingested. Accordingly, advertising strategy is centered on consumer awareness of the product as the primary goal. Educational commitment, however, did not seem to be blended into the promotional efforts for over-the-counter drugs. Findings on the symbolic content of over-the-counter drug ads reveal that drug images have been distorted. Performance of most drugs has been portrayed to be simple resolutions to relieve the symptom. Moreover, a casual attitude toward drug usage is encouraged in the commercials, while time lapse of drug effects is overlooked.

  18. 26 CFR 1.1092(c)-3 - Qualifying over-the-counter options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Qualifying over-the-counter options. 1.1092(c)-3...-counter options. (a) In general. Under section 1092(c)(4)(B)(i), an equity option is not a qualified covered call option unless it is traded on a national securities exchange that is registered with the...

  19. Over-the-counter sales of antibiotics from community pharmacies in Abu Dhabi.

    PubMed

    Dameh, Majd; Green, James; Norris, Pauline

    2010-10-01

    The aim of this study is to investigate over-the-counter sale of antibiotics from community pharmacies in Abu Dhabi city, focusing on the extent, demographic and socioeconomic determinants of this practice. The study was conducted in the capital of the United Arab Emirates, Abu Dhabi, and involved 17 randomly selected private pharmacies. A cross-sectional design using structured observations of 30 clients purchasing antibiotics from a pharmacy staff (either a pharmacist or pharmacy assistant) at each selected pharmacy. A total of 510 interactions were observed. Statistical analysis was performed using SPSS. The extent and types of antibiotics sold over-the-counter in Abu Dhabi city as observed in the selected sample of community pharmacies, and the demographic and socioeconomic factors that contributed to this practice. Sixty eight percent (68.4%) of the observed antibiotic sales were sold over-the-counter without prescriptions. Injection antibiotics constituted 2.2% of the antibiotics sold, 45.5% of which were sold over-the-counter. Combination of penicillins including β-lactamase inhibitors (34.0%), penicillins with extended spectrum (22.3%) and second generation cephalosporins (11.2%) were the mostly commonly sold antibiotic groups. Respiratory conditions (63.1%) were the most frequent reason for purchasing antibiotics. Over-the-counter sales of antibiotics were related to client ethnicity and age, gender of pharmacy staff and health complaint. Our study revealed high sales of over-the-counter antibiotics, despite this being illegal. The ineffectiveness of antibiotics in treating respiratory conditions of viral origin and effects of such practice on the emergence of bacterial resistance necessitates prompt action.

  20. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    NASA Technical Reports Server (NTRS)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  1. Hispanic youth involvement in over-the-counter drug use: parent, peer, and school factors.

    PubMed

    Vidourek, Rebecca A; King, Keith A; Fehr, Sara K

    2014-01-01

    Research on substance use among Hispanic youth is lacking. The purpose of this study was to examine over-the-counter drug use among Hispanic youth. Of Hispanic youth, 23.9% used an over-the-counter drug for the purpose of getting high. Involvement in prosocial behaviors was correlated with decreased over-the-counter use for females and high school students. Involvement in risky behaviors increased the risk of use for males, females, junior high school students, and high school students. Significant differences were found based on parent, peer, teacher, and school factors. Prevention and intervention programs should address over-the-counter drug use among Hispanic youth.

  2. Effect of angular inflow on the vibratory response of a counter-rotating propeller

    NASA Technical Reports Server (NTRS)

    Turnberg, J. E.; Brown, P. C.

    1985-01-01

    This report presents the results of a propeller vibratory stress survey on the Fairey Gannet aircraft aimed at giving an assessment of the difference in vibratory response between single and counter-rotating propeller operation in angular inflow. The survey showed that counter-rotating operation of the propeller had the effect of increasing the IP response of the rear propeller by approximately 25 percent over comparable single-rotation operation while counter-rotating operation did not significantly influence the IP response of the front propeller.

  3. COUNTER-REVOLUTION IN FOREIGN LANGUAGE TEACHING.

    ERIC Educational Resources Information Center

    HOCKING, ELTON

    THE AUTHOR STATES THAT THE AUDIOLINGUAL REVOLUTION IS BEING SUBJECTED TO A COUNTER-REVOLUTION IS APPARENT IN SUCH RECENT DEVELOPMENTS AS THE 1966 NORTHEAST CONFERENCE, WHEN CARROLL, FERGUSON, AND CHOMSKY DENIED THAT PSYCHOLOGY AND LINGUISTICS PROVIDE DIRECT SUPPORT FOR AUDIOLINGUAL TEACHING, THE WRITINGS OF RIVERS, HAYES, BELASCO, AND VALDMAN WHO…

  4. Covert Approaches to Countering Adult Chemophobia

    ERIC Educational Resources Information Center

    Billington, Susan; Smith, Robert B.; Karousos, Nikolaos G.; Cowham, Emma; Davis, James

    2008-01-01

    There is a growing need for more proactive outreach by universities to the wider public to counter the negative publicity surrounding chemistry. At present, most programs aimed at widening participation focus on the potential recruitment of juniors rather than seeking an inclusive approach. The direct participation of adults within university…

  5. A compact gas-filled avalanche counter for DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C. Y.; Chyzh, A.; Kwan, E.

    2012-08-04

    A compact gas-filled avalanche counter for the detection of fission fragments was developed for a highly segmented 4π γ-ray calorimeter, namely the Detector for Advanced Neutron Capture Experiments located at the Lujan Center of the Los Alamos Neutron Science Center. It has been used successfully for experiments with 235U, 238Pu, 239Pu, and 241Pu isotopes to provide a unique signature to differentiate the fission from the competing neutron-capture reaction channel. We also used it to study the spontaneous fission in 252Cf. The design and performance of this avalanche counter for targets with extreme α-decay rate up to ~2.4×108/s are described.

  6. Parental misinterpretations of over-the-counter pediatric cough and cold medication labels.

    PubMed

    Lokker, Nicole; Sanders, Lee; Perrin, Eliana M; Kumar, Disha; Finkle, Joanne; Franco, Vivian; Choi, Leena; Johnston, Philip E; Rothman, Russell L

    2009-06-01

    Concerns about the safety and efficacy of over-the-counter cold medications have led to a recent US Food and Drug Administration public health advisory against their use in children <2 years of age. Our goal was to examine caregiver understanding of the age indication of over-the-counter cold medication labels and identify factors, associated with caregiver understanding. Caregivers of infant children (< or =1 year old) were recruited from clinics at 3 institutions. Questions were administered regarding the use of 4 previously common "infant" over-the-counter cold and cough medicines labeled to consult a physician if used in children <2 years of age. Literacy and numeracy skills were assessed with validated instruments. A total of 182 caregivers were recruited; 87% were the infants' mothers. Mean education level was 12.5 years, and 99% had adequate literacy skills, but only 17% had >9th-grade numeracy skills. When examining the front of the product label, 86% of the time parents thought these products were appropriate for use in children <2 years of age. More than 50% of the time, parents stated they would give these over-the-counter products to a 13-month-old child with cold symptoms. Common factors that influenced parental decisions included label saying "infant," graphics (eg, infants, teddy bears, droppers), and dosing directions. Caregivers were influenced by the dosing directions only 47% of the time. Caregivers with lower numeracy skills were more likely to provide inappropriate reasons for giving an over-the-counter medication. Misunderstanding of over-the-counter cold products is common and could result in harm if medications are given inappropriately. Label language and graphics seem to influence inappropriate interpretation of over-the-counter product age indications. Poorer parental numeracy skills may increase the misinterpretation of these products. Opportunities exist for the Food and Drug Administration and manufacturers to revise existing labels to

  7. Symmetry Breaking of Counter-Propagating Light in a Nonlinear Resonator.

    PubMed

    Del Bino, Leonardo; Silver, Jonathan M; Stebbings, Sarah L; Del'Haye, Pascal

    2017-02-21

    Spontaneous symmetry breaking is a concept of fundamental importance in many areas of physics, underpinning such diverse phenomena as ferromagnetism, superconductivity, superfluidity and the Higgs mechanism. Here we demonstrate nonreciprocity and spontaneous symmetry breaking between counter-propagating light in dielectric microresonators. The symmetry breaking corresponds to a resonance frequency splitting that allows only one of two counter-propagating (but otherwise identical) states of light to circulate in the resonator. Equivalently, this effect can be seen as the collapse of standing waves and transition to travelling waves within the resonator. We present theoretical calculations to show that the symmetry breaking is induced by Kerr-nonlinearity-mediated interaction between the counter-propagating light. Our findings pave the way for a variety of applications including optically controllable circulators and isolators, all-optical switching, nonlinear-enhanced rotation sensing, optical flip-flops for photonic memories as well as exceptionally sensitive power and refractive index sensors.

  8. Collar height and heel counter-stiffness for ankle stability and athletic performance in basketball.

    PubMed

    Liu, Hui; Wu, Zitian; Lam, Wing-Kai

    2017-01-01

    This study examined the effects of collar height and heel counter-stiffness of basketball shoes on ankle stability during sidestep cutting and athletic performance. 15 university basketball players wore customized shoes with different collar heights (high and low) and heel counter-stiffness (regular, stiffer and stiffest) for this study. Ankle stability was evaluated in sidestep cutting while athletic performance evaluated in jumping and agility tasks. All variables were analysed using two-way repeated ANOVA. Results showed shorter time to peak ankle inversion for both high collar and stiff heel counter conditions (P < 0.05), while smaller initial ankle inversion angle, peak inversion velocity and total range of inversion for wearing high collar shoes (P < 0.05). No shoe differences were found for performance variables. These findings imply that the collar height might play a larger role in lateral stability than heel counter-stiffness, while both collar height and counter-stiffness have no effect on athletic performance.

  9. Pedagogical Injustice and Counter-Terrorist Education

    ERIC Educational Resources Information Center

    O'Donnell, Aislinn

    2017-01-01

    This article addresses the way in which the securitisation of education, effected through initiatives in counter-terrorism such as Prevent, leads to what I call "pedagogical injustice" for students and teachers. It analyses the implications of the pre-crime agenda in the space of the classroom and draws upon literature on epistemic…

  10. High School Equivalency as Counter-Space

    ERIC Educational Resources Information Center

    Schwartz, Joni

    2014-01-01

    This chapter is based on the findings of an ethnographic study of an urban General Education Development (GED®) program and suggests that, for some marginalized African American and other young men of color, adult education programs are counter-spaces (Yosso, Ceja, Smith, & Solorzano, [Yosso, T., 2009]) of spatial justice in opposition to…

  11. Effectiveness of a Television Counter Advertisement.

    ERIC Educational Resources Information Center

    Lull, James T.; Mulac, Anthony

    This paper investigates the potential effectiveness of counter advertising in influencing the buying habits of a convinced audience. One month before the actual study, 109 subjects indicated a brand preference in a consumer questionnaire. The subjects were randomly assigned to groups that viewed one of the following: (1) a pro-Bayer aspirin…

  12. Transitioning the second-generation antihistamines to over-the-counter status: a cost-effectiveness analysis.

    PubMed

    Sullivan, Patrick W; Follin, Sheryl L; Nichol, Michael B

    2003-12-01

    A U.S. Food and Drug Administration advisory committee deemed the second-generation antihistamines (SGA) safe for over-the-counter use against the preliminary opposition of the manufacturers. As a result, loratadine is now available over-the-counter. First-generation antihistamines (FGA) are associated with an increased risk of unintentional injuries, fatalities, and reduced productivity. Access to SGA over-the-counter could result in decreased use of FGA, thereby reducing deleterious outcomes. The societal impact of transitioning this class of medications from prescription to over-the-counter status has important policy implications. To examine the cost-effectiveness of transitioning SGA to over-the-counter status from a societal perspective. A simulation model of the decision to transition SGA to over-the-counter status was compared with retaining prescription-only status for a hypothetical cohort of individuals with allergic rhinitis in the United States. Estimates of costs and effectiveness were obtained from the medical literature and national surveys. Sensitivity analysis was performed using a second-order Monte Carlo simulation. Discounted, quality-adjusted life-years saved as a result of amelioration of allergic rhinitis symptoms and avoidance of motor vehicle, occupational, public and home injuries and fatalities; discounted direct and indirect costs. Availability of SGA over-the-counter was associated with annual savings of 4 billion dollars (2.4-5.3 billion dollars) or 100 dollars (64-137 dollars) per allergic rhinitis sufferer and 135,061 time-discounted quality-adjusted life years (84,913-191,802). The sensitivity analysis provides evidence in support of these results. Making SGA available over-the-counter is both cost-saving and more effective for society, largely as a result of reduced adverse outcomes associated with FGA-induced sedation. Further study is needed to determine the differential impact on specific vulnerable populations.

  13. Frequency-tuned microwave photon counter based on a superconductive quantum interferometer

    NASA Astrophysics Data System (ADS)

    Shnyrkov, V. I.; Yangcao, Wu; Soroka, A. A.; Turutanov, O. G.; Lyakhno, V. Yu.

    2018-03-01

    Various types of single-photon counters operating in infrared, ultraviolet, and optical wavelength ranges are successfully used to study electromagnetic fields, analyze radiation sources, and solve problems in quantum informatics. However, their operating principles become ineffective at millimeter band, S-band, and ultra-high frequency bands of wavelengths due to the decrease in quantum energy by 4-5 orders of magnitude. Josephson circuits with discrete Hamiltonians and qubits are a good foundation for the construction of single-photon counters at these frequencies. This paper presents a frequency-tuned microwave photon counter based on a single-junction superconducting quantum interferometer and flux qutrit. The control pulse converts the interferometer into a two-level system for resonance absorption of photons. Decay of the photon-induced excited state changes the magnetic flux in the interferometer, which is measured by a SQUID magnetometer. Schemes for recording the magnetic flux using a DC SQUID or ideal parametric detector, based on a qutrit with high-frequency excitation, are discussed. It is shown that the counter consisting of an interferometer with a Josephson junction and a parametric detector demonstrates high performance and is capable of detecting single photons in a microwave band.

  14. Transference, counter-transference and repetition: some implications for nursing practice.

    PubMed

    Jones, Alun C

    2005-11-01

    This discussion paper offers an introductory text for nurses and explores the psychoanalytic ideas of transference, counter-transference and repetition compulsion. Disguised case vignettes provide illustrations of the ideas as they might apply to nursing, including professional practice and occupational choice. The literature suggests that transference can be a source of creativity as well as destructiveness and influence important communications with oneself and others including the choice of nursing and other health professions as an occupation. Recognizing possibilities of transference, counter-transference along with repetitive patterns of behaviours, can help nurses of all specialities to address situations constructively by responding thoughtfully and appropriately. This discussion concludes with the suggestions that we know little about the motivational factors underlying nursing as an occupational preference; moreover, nursing does not have a culture of personal therapy. As such nurses are denied opportunities to understand the possible reasons underlying their occupational choice or gain experiential knowledge of interpersonal dynamics occurring between patients and colleagues. Transference and counter-transference are thought to have some bearing on all relationships. Forming a natural part of the way human beings relate to each other, transference and counter-transference can bring about sincere human interest, caring and concern. However, there is also potential for disagreements. Recognizing the possible origins of relational difficulties can offer opportunities for professional development to nurses along with the benefits for health service users.

  15. Mechanism of supporting sub-communicator collectives with O(64) counters as opposed to one counter for each sub-communicator

    DOEpatents

    Kumar, Sameer; Mamidala, Amith R.; Ratterman, Joseph D.; Blocksome, Michael; Miller, Douglas

    2013-09-03

    A system and method for enhancing barrier collective synchronization on a computer system comprises a computer system including a data storage device. The computer system includes a program stored in the data storage device and steps of the program being executed by a processor. The system includes providing a plurality of communicators for storing state information for a bather algorithm. Each communicator designates a master core in a multi-processor environment of the computer system. The system allocates or designates one counter for each of a plurality of threads. The system configures a table with a number of entries equal to the maximum number of threads. The system sets a table entry with an ID associated with a communicator when a process thread initiates a collective. The system determines an allocated or designated counter by searching entries in the table.

  16. Counter Trafficking System Development "Analysis Training Program"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Dennis C.

    This document will detail the training curriculum for the Counter-Trafficking System Development (CTSD) Analysis Modules and Lesson Plans are derived from the United States Military, Department of Energy doctrine and Lawrence Livermore National Laboratory (LLNL), Global Security (GS) S Program.

  17. Strengthening of the Coordination Shell by Counter Ions in Aqueous Th 4+ Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atta-Fynn, Raymond; Bylaska, Eric J.; de Jong, Wibe A.

    The presence of counter ions in solutions containing highly charged metal cations can trigger processes such as ion-pair formation, hydrogen bond breakages and subsequent reformation, and ligand exchanges. In this work, it is shown how halide (Cl-, Br-) and perchlorate (ClO4-) anions affect the strength of the primary solvent coordination shells around Th4+ using explicit solvent and finite temperature ab initio molecular dynamics modeling methods. The 9-fold solvent geometry was found to be the most stable hydration structure in each aqueous solution. Relative to the dilute aqueous solution, the presence of the counter ions did not significantly alter the geometrymore » of the primary hydration shell. However, the free energy analyses indicated that the 10-fold hydrated states were thermodynamically accessible in dilute and bromide aqueous solutions within 1 kcal/mol. Analysis of the results showed that the hydrogen bond lifetimes were longer and solvent exchange energy barriers were larger in solutions with counter ions in comparison with the solution with no counter ions. This implies that the presence of the counter ions induces a strengthening of the Th4+ hydration shell.« less

  18. Expertise in unexpected places: Children's acceptance of information from gender counter-stereotypical experts.

    PubMed

    Boseovski, Janet J; Hughes, Chelsea; Miller, Stephanie E

    2016-01-01

    The current study examined children's willingness to accept novel information from expert informants with nontraditional gender role interests. Four- to 8-year-olds heard conflicting information about traditionally feminine or masculine domains from a gender counter-stereotypical expert (e.g., a boy with expertise in ballet) and a layperson of the other gender (e.g., a girl with little knowledge about ballet). Participants were asked which informant was correct, who they would prefer to learn from in the future, and to rate their liking of each informant. Overall, participants selected the gender counter-stereotypical expert as correct. Four- to 5-year-olds reported a preference to learn from same-gender participants in the future irrespective of expertise, whereas 6- to 8-year-olds reported wanting to learn from counter-stereotypical experts. Boys showed relatively greater acceptance of information from a male counter-stereotypical expert than from a female counter-stereotypical expert. Although participants reported greater liking of same-gender informants, liking evaluations were largely positive irrespective of gender norm deviations. Implications for children's acceptance of gender nonconforming activities are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Diasporic Philosophy, Counter-Education and Improvisation

    ERIC Educational Resources Information Center

    Gur-Ze'ev, Ilan

    2010-01-01

    Counter-education that addresses seriously the challenge of loss, exile, and the deceiving "home-returning" projects accepts that no positive Utopia awaits us as "truth", "genuine life", "worthy struggle", "pleasure" or worthy self-annihilation. Loss is not to be recovered or compensated; not for the individual nor for any kind of "we". And yet,…

  20. The remote controlling technique based on the serial port for SR-620 universal counter

    NASA Astrophysics Data System (ADS)

    Su, Jian-Feng; Chen, Shu-Fang; Li, Xiao-Hui; Wu, Hai-Tao; Bian, Yu-Jing

    2004-12-01

    The function of SR-620 universal counter and the remote work mode are introduced, and the remote controlling technique for the counter is analysed. A method to realize the remote controlling via the serial port for the counter is demonstrated, in which an ActiveX control is used. Besides, some points for attention in debugging are discussed based on the experience, and a case of program running for measuring time-delay is presented.

  1. Results on the Performance of a Broad Band Focussing Cherenkov Counter

    DOE R&D Accomplishments Database

    Cester, R.; Fitch, V. L.; Montag, A.; Sherman, S.; Webb, R. C.; Witherell, M. S.

    1980-01-01

    The field of ring imaging (broad band differential) Cherenkov detectors has become a very active area of interest in detector development at several high energy physics laboratories. Our group has previously reported on a method of Cherenkov ring imaging for a counter with large momentum and angular acceptance using standard photo multipliers. Recently, we have applied this technique to the design of a set of Cherenkov counters for use in a particle search experiment at Fermi National Accelerator Laboratory (FNAL). This new detector operates over the range 0.998 < ..beta.. < 1.000 in velocity with a delta..beta.. approx. 2 x 10{sup -4}. The acceptance in angle is +- 14 mrad in the horizontal and +- 28 mrad in the vertical. We report here on the performance of this counter.

  2. Racism and Linguicism: Engaging Language Minority Pre-Service Teachers in Counter-Storytelling

    ERIC Educational Resources Information Center

    Cho, Hyesun

    2017-01-01

    This study examines how language minority pre-service teachers engaged in the discussion of racism and linguicism through counter-storytelling informed by Critical Race Theory (CRT). Counter-stories can act as a medium through which minority students can unpack the power relations embedded in academic learning. This study also explores ways in…

  3. Proportion of recovered waterfowl bands reported

    USGS Publications Warehouse

    Geis, A.D.; Atwood, E.L.

    1961-01-01

    Data from the annual mail survey of waterfowl hunters in the United States were used to estimate the total numbers of banded waterfowl that were shot. These estimates were compared with Banding Office records to estimate the proportion of recovered bands that was reported. On the average, about two banded birds were recovered for each one reported. The proportion reported was higher for some areas and for some species than for others. The proportion reported was higher when more of the reports came through employees of conservation agencies.

  4. Using culture and psychology to counter the Taliban's violent narratives.

    PubMed

    Aggarwal, Neil Krishan

    2017-08-01

    Scholars, politicians, and policy-makers have increasingly pointed to the role of narratives in recruiting militants and justifying violence, highlighting the need for counter-narratives that promote peace. However, few have offered concrete guidelines on how to construct counter-narratives. This exploratory study uses prototype theory from social psychology to analyse Taliban narratives written in Arabic on the historical figure Maḥmūd of Ghaznī (971-1030), who is portrayed as a figure worthy of emulation. Key themes emerge from the Taliban's narratives: potential ingroup members are defined as Sunni Muslims who are committed to jihad; deviant Muslims must become Sunnis; non-Muslims must be converted and humiliated; and Taliban leaders should emulate Maḥmūd of Ghaznī's attributes. Contrasting the Taliban's narratives of Maḥmūd of Ghaznī with the historical record reveals themes that are culled empirically around which counter-narratives could be constructed.

  5. Symmetry Breaking of Counter-Propagating Light in a Nonlinear Resonator

    PubMed Central

    Del Bino, Leonardo; Silver, Jonathan M.; Stebbings, Sarah L.; Del'Haye, Pascal

    2017-01-01

    Spontaneous symmetry breaking is a concept of fundamental importance in many areas of physics, underpinning such diverse phenomena as ferromagnetism, superconductivity, superfluidity and the Higgs mechanism. Here we demonstrate nonreciprocity and spontaneous symmetry breaking between counter-propagating light in dielectric microresonators. The symmetry breaking corresponds to a resonance frequency splitting that allows only one of two counter-propagating (but otherwise identical) states of light to circulate in the resonator. Equivalently, this effect can be seen as the collapse of standing waves and transition to travelling waves within the resonator. We present theoretical calculations to show that the symmetry breaking is induced by Kerr-nonlinearity-mediated interaction between the counter-propagating light. Our findings pave the way for a variety of applications including optically controllable circulators and isolators, all-optical switching, nonlinear-enhanced rotation sensing, optical flip-flops for photonic memories as well as exceptionally sensitive power and refractive index sensors. PMID:28220865

  6. Icon arrays help younger children's proportional reasoning.

    PubMed

    Ruggeri, Azzurra; Vagharchakian, Laurianne; Xu, Fei

    2018-06-01

    We investigated the effects of two context variables, presentation format (icon arrays or numerical frequencies) and time limitation (limited or unlimited time), on the proportional reasoning abilities of children aged 7 and 10 years, as well as adults. Participants had to select, between two sets of tokens, the one that offered the highest likelihood of drawing a gold token, that is, the set of elements with the greater proportion of gold tokens. Results show that participants performed better in the unlimited time condition. Moreover, besides a general developmental improvement in accuracy, our results show that younger children performed better when proportions were presented as icon arrays, whereas older children and adults were similarly accurate in the two presentation format conditions. Statement of contribution What is already known on this subject? There is a developmental improvement in proportional reasoning accuracy. Icon arrays facilitate reasoning in adults with low numeracy. What does this study add? Participants were more accurate when they were given more time to make the proportional judgement. Younger children's proportional reasoning was more accurate when they were presented with icon arrays. Proportional reasoning abilities correlate with working memory, approximate number system, and subitizing skills. © 2018 The British Psychological Society.

  7. Ultrafine Condensation Particle Counter Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuang, C.

    2016-02-01

    The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

  8. Prompt emission from the counter jet of a short gamma-ray burst

    NASA Astrophysics Data System (ADS)

    Yamazaki, Ryo; Ioka, Kunihito; Nakamura, Takashi

    2018-03-01

    The counter jet of a short gamma-ray burst (sGRB) has not yet been observed, while recent discoveries of gravitational waves (GWs) from a binary neutron star merger GW170817 and the associated sGRB 170817A have demonstrated that off-axis sGRB jets are detectable. We calculate the prompt emission from the counter jet of an sGRB and show that it is typically 23-26 mag in the optical-infrared band 10-10^3 s after the GWs for an sGRB 170817A-like event, which is brighter than the early macronova (or kilonova) emission and detectable by LSST in the near future. We also propose a new method to constrain the unknown jet properties, such as the Lorentz factor, opening angle, emission radii, and jet launch time, by observing both the forward and counter jets. To scrutinize the counter jets, space GW detectors like DECIGO are powerful in forecasting the merger time (≲ 1 s) and position (≲ 1 arcmin) (˜ a week) before the merger.

  9. The effect of the use of a counter-torque device on the abutment-implant complex.

    PubMed

    Lang, L A; May, K B; Wang, R F

    1999-04-01

    Little is known about the condition of the abutment-screw joint before loading, after the development of the preload. This study examined the tightening force transmitted to the implant with and without the use of a counter-torque device during the tightening of the abutment screw. Forty Brânemark implants and 10 CeraOne, Estheticone, Procera, and AurAdapt abutments formed the experimental populations. Samples in each group were further divided into 2 groups, 1 group was tightened with a torque controller without the use of a counter-torque device, whereas the other used the counter-torque device. Samples were positioned in a special holder within the grips of a Tohnichi BTG-6 torque gauge for measuring transmitted forces. There were significant differences (P =. 0001) in the tightening forces transmitted to the implant with and without the use of a counter-torque device when tightening the abutment screws. An average of 91% of the recommended preload tightening torque was transmitted to the implant-bone interface in the absence of a counter-torque device. In all abutment systems, less than 10% of the recommended preload tightening torque was transmitted to the implant when the counter-torque device was used.

  10. Mechanism of supporting sub-communicator collectives with O(64) counters as opposed to one counter for each sub-communicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, Sameer; Mamidala, Amith R.; Ratterman, Joseph D.

    A system and method for enhancing barrier collective synchronization on a computer system comprises a computer system including a data storage device. The computer system includes a program stored in the data storage device and steps of the program being executed by a processor. The system includes providing a plurality of communicators for storing state information for a bather algorithm. Each communicator designates a master core in a multi-processor environment of the computer system. The system allocates or designates one counter for each of a plurality of threads. The system configures a table with a number of entries equal tomore » the maximum number of threads. The system sets a table entry with an ID associated with a communicator when a process thread initiates a collective. The system determines an allocated or designated counter by searching entries in the table.« less

  11. Mechanism of supporting sub-communicator collectives with o(64) counters as opposed to one counter for each sub-communicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blocksome, Michael; Kumar, Sameer; Mamidala, Amith R.

    A system and method for enhancing barrier collective synchronization on a computer system comprises a computer system including a data storage device. The computer system includes a program stored in the data storage device and steps of the program being executed by a processor. The system includes providing a plurality of communicators for storing state information for a barrier algorithm. Each communicator designates a master core in a multi-processor environment of the computer system. The system allocates or designates one counter for each of a plurality of threads. The system configures a table with a number of entries equal tomore » the maximum number of threads. The system sets a table entry with an ID associated with a communicator when a process thread initiates a collective. The system determines an allocated or designated counter by searching entries in the table.« less

  12. First observational evidence for the connection between the meteoric activity and occurrence of equatorial counter electrojet

    NASA Astrophysics Data System (ADS)

    Vineeth, C.; Mridula, N.; Muralikrishna, P.; Kumar, K. K.; Pant, T. K.

    2016-09-01

    This paper presents the first direct observational evidence for the possible role of meteoric activity in the generation of the equatorial Counter Electrojets (CEJ), an enigmatic daytime electrodynamical process over the geomagnetic equatorial upper atmosphere. The investigation carried out using the data from Proton Precession Magnetometer and Meteor Wind Radar over a geomagnetic dip equatorial station, Trivandrum (8.5°N, 77°E, 0.5°N dip lat.) in India, revealed that the occurrence of the afternoon CEJ events during a month is directly proportional to the average monthly meteor counts over this location. The observation is found to be very consistent during the considered period of study, i.e the years 2006 and 2007. The study vindicates that the meteor showers play a major role in setting up the background condition conducive for the generation of CEJ by reducing the strength of the upward polarization field.

  13. Nanopatterned conductive polymer films as a Pt, TCO-free counter electrode for low-cost dye-sensitized solar cells.

    PubMed

    Kwon, Jeong; Ganapathy, Veerappan; Kim, Young Hun; Song, Kyung-Deok; Park, Hong-Gyu; Jun, Yongseok; Yoo, Pil J; Park, Jong Hyeok

    2013-09-07

    A low-cost nanopatterned highly conductive poly(3,4-ethylenedioxythiophene) (PEDOT) thin film was fabricated on a flexible plastic substrate via a chemical polymerization method combined with a nanoimprinting technique and used as a platinum (Pt), TCO-free counter electrode for dye-sensitized solar cells (DSSCs). The catalytic properties of the nanopatterned PEDOT as the counter electrode in DSSCs were studied using cyclic voltammetry, J-V measurements, impedance spectroscopy, and finite-difference time-domain (FDTD) simulations. The nanopatterned PEDOT counter electrodes exhibit better functionality as a counter electrode for tri-iodide reduction when compared to non-patterned PEDOT-based counter electrodes. The Pt and TCO-free DSSCs with a nanopatterned PEDOT-based counter electrode exhibited a power conversion efficiency of 7.1% under one sunlight illumination (100 mW cm(-2)), which is comparable to that of conventional DSSCs with standard platinum Pt/FTO paired counter electrodes. The ability to modulate catalytic functionality with changes in nanoscale morphology represents a promising route for developing new counter electrodes of Pt and TCO-free DSSCs.

  14. Plasmonic-enhanced graphene flake counter electrodes for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Kim, Hyun-Young; Lee, Myung Woo; Song, Da Hyun; Yoon, Hyeok Jin; Suh, Jung Sang

    2017-06-01

    A plasmonic-enhanced graphene flake counter electrode for dye-sensitized solar cells (DSSCs) was fabricated by immobilization of gold nanoparticles (NPs) on fluorine-doped tin oxide (FTO) glass and the deposition of a thin layer of graphene flakes. The graphene flakes, fabricated using a thermal plasma jet system, were very thin and pure and had good crystallinity. Even though their average size is larger than 100 nm, they had great dispersibility in common solvents. Their relatively large size and good crystallinity resulted in good conductivity, and their good dispersibility allowed us to fabricate relatively uniform films. The efficiency of the DSSC with a graphene flake/Au NP/FTO counter electrode was as much as 9.78%, which is higher than that with a conventional Pt/FTO (9.08%) or graphene flake/FTO (8.98%) counter electrode. Using cyclic voltammograms and electrochemical impedance spectroscopy and by measuring the incident photo-conversion efficiency, we proved that by the localized surface plasmon resonance effect of the Au NPs included between the graphene flakes and FTO, the charge-transfer resistance at the electrode/electrolyte interface was decreased. Consequently, the catalytic rate for I- regeneration improved, and the energy conversion efficiency of the DSSC with a graphene flake/Au NP/FTO counter electrode improved.

  15. Strategies for an effective youth counter-marketing program: recommendations from commercial marketing experts.

    PubMed

    McKenna, J; Gutierrez, K; McCall, K

    2000-05-01

    Intensive and sustained efforts to "counter-market" tobacco among teenagers are necessary to negate the "friendly familiarity" created by tobacco advertising and to communicate the true health and social costs of tobacco use. Counter-marketing campaigns should: highlight a tobacco-free lifestyle as the majority lifestyle of diverse and interesting individuals; explain the dangers of tobacco in a personal, emotional way; offer youth empowerment and control; use multiple voices, strategies, and executions; offer constructive alternatives to tobacco use; and portray smoking as unacceptable and undesirable for everyone. Counter-marketing activities should work in concert with other interventions to alter social norms regarding tobacco.

  16. Nitrous Oxide Production in Co- Versus Counter-Diffusion Nitrifying Biofilms

    PubMed Central

    Peng, Lai; Sun, Jing; Liu, Yiwen; Dai, Xiaohu; Ni, Bing-Jie

    2016-01-01

    For the application of biofilm processes, a better understanding of nitrous oxide (N2O) formation within the biofilm is essential for design and operation of biofilm reactors with minimized N2O emissions. In this work, a previously established N2O model incorporating both ammonia oxidizing bacteria (AOB) denitrification and hydroxylamine (NH2OH) oxidation pathways is applied in two structurally different biofilm systems to assess the effects of co- and counter-diffusion on N2O production. It is demonstrated that the diffusion of NH2OH and oxygen within both types of biofilms would form an anoxic layer with the presence of NH2OH and nitrite ( ), which would result in a high N2O production via AOB denitrification pathway. As a result, AOB denitrification pathway is dominant over NH2OH oxidation pathway within the co- and counter-diffusion biofilms. In comparison, the co-diffusion biofilm may generate substantially higher N2O than the counter-diffusion biofilm due to the higher accumulation of NH2OH in co-diffusion biofilm, especially under the condition of high-strength ammonium influent (500 mg N/L), thick biofilm depth (300 μm) and moderate oxygen loading (~1–~4 m3/d). The effect of co- and counter-diffusion on N2O production from the AOB biofilm is minimal when treating low-strength nitrogenous wastewater. PMID:27353382

  17. Nitrous Oxide Production in Co- Versus Counter-Diffusion Nitrifying Biofilms

    NASA Astrophysics Data System (ADS)

    Peng, Lai; Sun, Jing; Liu, Yiwen; Dai, Xiaohu; Ni, Bing-Jie

    2016-06-01

    For the application of biofilm processes, a better understanding of nitrous oxide (N2O) formation within the biofilm is essential for design and operation of biofilm reactors with minimized N2O emissions. In this work, a previously established N2O model incorporating both ammonia oxidizing bacteria (AOB) denitrification and hydroxylamine (NH2OH) oxidation pathways is applied in two structurally different biofilm systems to assess the effects of co- and counter-diffusion on N2O production. It is demonstrated that the diffusion of NH2OH and oxygen within both types of biofilms would form an anoxic layer with the presence of NH2OH and nitrite ( ), which would result in a high N2O production via AOB denitrification pathway. As a result, AOB denitrification pathway is dominant over NH2OH oxidation pathway within the co- and counter-diffusion biofilms. In comparison, the co-diffusion biofilm may generate substantially higher N2O than the counter-diffusion biofilm due to the higher accumulation of NH2OH in co-diffusion biofilm, especially under the condition of high-strength ammonium influent (500 mg N/L), thick biofilm depth (300 μm) and moderate oxygen loading (~1-~4 m3/d). The effect of co- and counter-diffusion on N2O production from the AOB biofilm is minimal when treating low-strength nitrogenous wastewater.

  18. Proportional Reasoning and the Visually Impaired

    ERIC Educational Resources Information Center

    Hilton, Geoff; Hilton, Annette; Dole, Shelley L.; Goos, Merrilyn; O'Brien, Mia

    2012-01-01

    Proportional reasoning is an important aspect of formal thinking that is acquired during the developmental years that approximate the middle years of schooling. Students who fail to acquire sound proportional reasoning often experience difficulties in subjects that require quantitative thinking, such as science, technology, engineering, and…

  19. Organizing Chaos: Restructuring Counter-Piracy Forces Off the Coast of Somalia

    DTIC Science & Technology

    2011-05-04

    the Maersk Alabama cargo ship. Prior to these attacks, most Americans were likely to associate a pirate with Hollywood’s mascara-wearing Johnny Depp...However, the approach to countering Somali pirates is disorganized. The international community attempts to achieve unity of effort by relying heavily...conducting counter-piracy as ―a good model not only for the Gulf of Aden and the Somali bases, but also for future such endeavors.‖ 12 Mr. Countryman

  20. Challenging Colorblindness in Arizona: Latina/o Students' Counter-Narratives of Race and Racism

    ERIC Educational Resources Information Center

    Cammarota, Julio

    2014-01-01

    This essay reviews Latina/o students' counter-narratives challenging colorblindness. The author highlights the experiences of students from Tucson Unified School District's Mexican American Studies program. By examining student counter-narratives, the author also identifies race-related terms that are more suitable for dialogue among and with…

  1. Platelet counting using the Coulter electronic counter.

    PubMed

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  2. 21 CFR 866.2170 - Automated colony counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated colony counter. 866.2170 Section 866.2170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony...

  3. 21 CFR 866.2170 - Automated colony counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated colony counter. 866.2170 Section 866.2170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony...

  4. 21 CFR 866.2170 - Automated colony counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated colony counter. 866.2170 Section 866.2170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony...

  5. 21 CFR 866.2170 - Automated colony counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated colony counter. 866.2170 Section 866.2170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony...

  6. 21 CFR 866.2170 - Automated colony counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated colony counter. 866.2170 Section 866.2170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony...

  7. Strategies for Countering Terrorist Safe Havens

    DTIC Science & Technology

    2013-12-01

    tactical containment, pseudo operations, and surrogate security forces. The thesis draws from four historical case studies to examine these strategies...safe havens, tactical containment, pseudo operations, and surrogate security forces. The thesis draws from four historical case studies to examine...pseudo operations—provide viable potential options for USSOF to counter the complex problem of safe havens. Overall, the case studies will demonstrate

  8. Strategies for Countering Terrorist Safe Havens

    DTIC Science & Technology

    2014-02-20

    within safe havens, tactical containment, pseudo operations, and surrogate security forces. The thesis draws from four historical case studies to...leadership targeting within safe havens, tactical containment, pseudo operations, and surrogate security forces. The thesis draws from four historical case ...surrogate forces and pseudo operations—provide viable potential options for USSOF to counter the complex problem of safe havens. Overall, the case

  9. PLASMA EMISSION BY COUNTER-STREAMING ELECTRON BEAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziebell, L. F.; Petruzzellis, L. T.; Gaelzer, R.

    2016-02-10

    The radiation emission mechanism responsible for both type-II and type-III solar radio bursts is commonly accepted as plasma emission. Recently Ganse et al. suggested that type-II radio bursts may be enhanced when the electron foreshock geometry of a coronal mass ejection contains a double hump structure. They reasoned that the counter-streaming electron beams that exist between the double shocks may enhance the nonlinear coalescence interaction, thereby giving rise to more efficient generation of radiation. Ganse et al. employed a particle-in-cell simulation to study such a scenario. The present paper revisits the same problem with EM weak turbulence theory, and showmore » that the fundamental (F) emission is not greatly affected by the presence of counter-streaming beams, but the harmonic (H) emission becomes somewhat more effective when the two beams are present. The present finding is thus complementary to the work by Ganse et al.« less

  10. The effect of over-the-counter sales of the nicotine patch and nicotine gum on smoking cessation in California.

    PubMed

    Reed, Mark B; Anderson, Christy M; Vaughn, Jerry W; Burns, David M

    2005-09-01

    The Food and Drug Administration approved over-the-counter (OTC) sale of nicotine gum and nicotine patches in 1996. We used data from the 1996 California Tobacco Survey to compare the rates of nicotine replacement therapy (NRT) use and smoking abstinence in California for each month during a period immediately preceding and immediately following the OTC availability of nicotine gum and patches. For smokers eligible to report a quit attempt, the proportion making a quit attempt using NRT and the proportion remaining abstinent was calculated for each of the 12 months prior to the survey interview. Multiple regression modeling of quit attempts and abstinence included a term for the number of months between the quit attempt and survey interview and dummy variables for the months before and after the OTC availability of NRT. Results showed a significant increase in the fraction of smokers using the patch (P < 0.01) and gum (P < 0.05) immediately following their availability OTC. There was also a significantly higher proportion of smokers reporting abstinence with gum use (P < 0.01) and a significant increase in reported abstinence with patch use (P < 0.01) during the period of time immediately following the availability of these products without a prescription. The results of this study suggest that removing the prescription status of NRT products resulted in an immediate increase in quit attempts and smoking abstinence with the use of nicotine gum or patches.

  11. Ti Porous Film-Supported NiCo₂S₄ Nanotubes Counter Electrode for Quantum-Dot-Sensitized Solar Cells.

    PubMed

    Deng, Jianping; Wang, Minqiang; Song, Xiaohui; Yang, Zhi; Yuan, Zhaolin

    2018-04-17

    In this paper, a novel Ti porous film-supported NiCo₂S₄ nanotube was fabricated by the acid etching and two-step hydrothermal method and then used as a counter electrode in a CdS/CdSe quantum-dot-sensitized solar cell. Measurements of the cyclic voltammetry, Tafel polarization curves, and electrochemical impedance spectroscopy of the symmetric cells revealed that compared with the conventional FTO (fluorine doped tin oxide)/Pt counter electrode, Ti porous film-supported NiCo₂S₄ nanotubes counter electrode exhibited greater electrocatalytic activity toward polysulfide electrolyte and lower charge-transfer resistance at the interface between electrolyte and counter electrode, which remarkably improved the fill factor, short-circuit current density, and power conversion efficiency of the quantum-dot-sensitized solar cell. Under illumination of one sun (100 mW/cm²), the quantum-dot-sensitized solar cell based on Ti porous film-supported NiCo₂S₄ nanotubes counter electrode achieved a power conversion efficiency of 3.14%, which is superior to the cell based on FTO/Pt counter electrode (1.3%).

  12. Bayesian Inference on Proportional Elections

    PubMed Central

    Brunello, Gabriel Hideki Vatanabe; Nakano, Eduardo Yoshio

    2015-01-01

    Polls for majoritarian voting systems usually show estimates of the percentage of votes for each candidate. However, proportional vote systems do not necessarily guarantee the candidate with the most percentage of votes will be elected. Thus, traditional methods used in majoritarian elections cannot be applied on proportional elections. In this context, the purpose of this paper was to perform a Bayesian inference on proportional elections considering the Brazilian system of seats distribution. More specifically, a methodology to answer the probability that a given party will have representation on the chamber of deputies was developed. Inferences were made on a Bayesian scenario using the Monte Carlo simulation technique, and the developed methodology was applied on data from the Brazilian elections for Members of the Legislative Assembly and Federal Chamber of Deputies in 2010. A performance rate was also presented to evaluate the efficiency of the methodology. Calculations and simulations were carried out using the free R statistical software. PMID:25786259

  13. Bayesian inference on proportional elections.

    PubMed

    Brunello, Gabriel Hideki Vatanabe; Nakano, Eduardo Yoshio

    2015-01-01

    Polls for majoritarian voting systems usually show estimates of the percentage of votes for each candidate. However, proportional vote systems do not necessarily guarantee the candidate with the most percentage of votes will be elected. Thus, traditional methods used in majoritarian elections cannot be applied on proportional elections. In this context, the purpose of this paper was to perform a Bayesian inference on proportional elections considering the Brazilian system of seats distribution. More specifically, a methodology to answer the probability that a given party will have representation on the chamber of deputies was developed. Inferences were made on a Bayesian scenario using the Monte Carlo simulation technique, and the developed methodology was applied on data from the Brazilian elections for Members of the Legislative Assembly and Federal Chamber of Deputies in 2010. A performance rate was also presented to evaluate the efficiency of the methodology. Calculations and simulations were carried out using the free R statistical software.

  14. SILAR deposition of nickel sulfide counter electrode for application in quantum dot sensitized solar cell

    NASA Astrophysics Data System (ADS)

    Singh, Navjot; Siwatch, Poonam; Arora, Anmol; Sharma, Jadab; Tripathi, S. K.

    2018-05-01

    Quantum Dot Sensitized Solar Cells are a likely replacement for Silicon-based solar cells. Counter electrodes are a fundamental aspect of QDSSC's performance. NiS being a less expensive material is a decent choice for the purpose. In this paper, we have discussed the synthesis of NiS by Successive Ionic Layer Adsorption Reaction. Optical, Crystallographic and Electrical studies have been presented. Electrical studies of the device with NiS counter electrode is compared with characteristics of the device with CNTs as the counter electrode. SILAR method is easy and less time to consume than chemical bath deposition or any other method. Results show the success of NiS synthesized by SILAR method as the counter electrode.

  15. Implications of Counter-Attitudinal Information Exposure in Further Information- Seeking and Attitude Change

    ERIC Educational Resources Information Center

    Lee, Sangwon

    2017-01-01

    Introduction: Given that people rely heavily on their party affiliation to make their political decisions, an interesting dilemma occurs when people are exposed to counter-attitudinal information from the party they identify with. This paper examines how exposure to counter-attitudinal messages from the party an individual identifies with…

  16. Hypothalamic AMP-activated protein kinase mediates counter-regulatory responses to hypoglycaemia in rats.

    PubMed

    Han, S-M; Namkoong, C; Jang, P G; Park, I S; Hong, S W; Katakami, H; Chun, S; Kim, S W; Park, J-Y; Lee, K-U; Kim, M-S

    2005-10-01

    Appropriate counter-regulatory hormonal responses are essential for recovery from hypoglycaemia. Although the hypothalamus is known to be involved in these responses, the molecular mechanisms have not been fully elucidated. AMP-activated protein kinase (AMPK) functions as a cellular energy sensor, being activated during energy depletion. As AMPK is expressed in the hypothalamus, an important site of neuroendocrine regulation, the present study was undertaken to determine whether hypothalamic AMPK mediates counter-regulatory responses to hypoglycaemia. Hypoglycaemia was induced by i.p. injection of regular insulin (6 U/kg) in Sprague-Dawley rats. Hypothalamic AMPK phosphorylation and activities were determined 1 h after i.p. insulin injection. To investigate the role of hypothalamic AMPK activation in mediating counter-regulatory responses, an AMPK inhibitor, compound C, was pre-administered intracerebroventricularly (i.c.v.) or dominant-negative (DN)-AMPK was overexpressed in the hypothalamus before induction of hypoglycaemia. Insulin-induced hypoglycaemia increased hypothalamic AMPK phosphorylation and alpha2-AMPK activities in rats. The change was significant in the arcuate nucleus/ventromedial hypothalamus (ARC/VMH) and paraventricular nuclei (PVN). Prior i.c.v. administration of compound C attenuated hypoglycaemia-induced increases in plasma concentrations of corticosterone, glucagon and catecholamines, resulting in severe and prolonged hypoglycaemia. ARC/VMH DN-AMPK overexpression impaired early counter-regulation, as evidenced by reduced glucagon and catecholamine responses. In contrast, PVN DN-AMPK overexpression attenuated late counter-regulation and corticosterone responses. Systemic hypoglycaemia causes hypothalamic AMPK activation, which is important for counter-regulatory hormonal responses. Our data indicate that hypothalamic AMPK acts as a fuel gauge, sensing the whole-body energy state and regulating not only energy homeostasis but also

  17. Assessing the relationship between pharmacists' job satisfaction and over-the-counter counselling at community pharmacies.

    PubMed

    Urbonas, Gvidas; Kubilienė, Loreta

    2016-04-01

    Community pharmacies have an increasing role in self-medication and community health is dependent on the quality of counselling services provided to patients. Some studies show that pharmacists' job satisfaction affects their work quality; other studies found that higher involvement in clinical services increases pharmacists' job satisfaction. To test the relationship between job satisfaction and over-the-counter counselling practice at community pharmacies. Community pharmacies in Lithuania. A convenience sample (n = 305) of community pharmacists participated in the cross-sectional survey where they expressed satisfaction with job and reported on their over-the-counter counselling behaviour on self-report scales. The Partial Least Squares Structural Equation Modelling approach was employed for data analysis. The strength of the relationship between job satisfaction and over-the-counter counselling service. A bidirectional relationship between job satisfaction and over-the-counter counselling service was found. In addition, job satisfaction and over-the-counter counselling quality depended on pharmacists' age. Organizations were recommended to create a counselling friendly environment that would increase pharmacists' job satisfaction and, in return, counselling quality. Also, additional motivation of the retired pharmacists, as well as development of counselling skills of the younger pharmacy workforce, were seen as a means to improve both organizational climate and counselling quality over the counter.

  18. Platelet counting using the Coulter electronic counter

    PubMed Central

    Eggleton, M. J.; Sharp, A. A.

    1963-01-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.1 The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed. PMID:16811002

  19. 78 FR 19718 - Modifications To Labeling of Nicotine Replacement Therapy Products for Over-the-Counter Human Use

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-02

    ...] Modifications To Labeling of Nicotine Replacement Therapy Products for Over-the-Counter Human Use AGENCY: Food...-counter nicotine replacement therapy products, related to concomitant use with other nicotine-containing... over-the- counter nicotine replacement therapy products for their approved intended use as aids to...

  20. Progress in Studying Scintillator Proportionality: Phenomenological Model

    NASA Astrophysics Data System (ADS)

    Bizarri, G.; Cherepy, N. J.; Choong, W. S.; Hull, G.; Moses, W. W.; Payne, S. A.; Singh, J.; Valentine, J. D.; Vasilev, A. N.; Williams, R. T.

    2009-08-01

    We present a model to describe the origin of non-proportional dependence of scintillator light yield on the energy of an ionizing particle. The non-proportionality is discussed in terms of energy relaxation channels and their linear and non-linear dependences on the deposited energy. In this approach, the scintillation response is described as a function of the deposited energy deposition and the kinetic rates of each relaxation channel. This mathematical framework allows both a qualitative interpretation and a quantitative fitting representation of scintillation non-proportionality response as function of kinetic rates. This method was successfully applied to thallium doped sodium iodide measured with SLYNCI, a new facility using the Compton coincidence technique. Finally, attention is given to the physical meaning of the dominant relaxation channels, and to the potential causes responsible for the scintillation non-proportionality. We find that thallium doped sodium iodide behaves as if non-proportionality is due to competition between radiative recombinations and non-radiative Auger processes.

  1. Advanced Prop-fan Engine Technology (APET) single- and counter-rotation gearbox/pitch change mechanism

    NASA Technical Reports Server (NTRS)

    Reynolds, C. N.

    1985-01-01

    The preliminary design of advanced technology (1992) turboprop engines for single-rotation prop-fans and conceptual designs of pitch change mechanisms for single- and counter-rotation prop-fan application are discussed. The single-rotation gearbox is a split path, in-line configuration. The counter-rotation gearbox is an in-line, differential planetary design. The pitch change mechanisms for both the single- and counter-rotation arrangements are rotary/hydraulic. The advanced technology single-rotation gearbox yields a 2.4 percent improvement in aircraft fuel burn and a one percent improvement in operating cost relative to a current technology gearbox. The 1992 counter-rotation gearbox is 15 percent lighter, 15 percent more reliable, 5 percent lower in cost, and 45 percent lower in maintenance cost than the 1992 single-rotation gearbox. The pitch controls are modular, accessible, and external.

  2. Interior view of Dispatch Office and counter, facing south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view of Dispatch Office and counter, facing south - International Longshoremen's & Warehousemen's Union Hall, Naval Civil Engineering Laboratory, Port Hueneme Road, Port Hueneme, Ventura County, CA

  3. CCSSM Challenge: Graphing Ratio and Proportion

    ERIC Educational Resources Information Center

    Kastberg, Signe E.; D'Ambrosio, Beatriz S.; Lynch-Davis, Kathleen; Mintos, Alexia; Krawczyk, Kathryn

    2013-01-01

    A renewed emphasis was placed on ratio and proportional reasoning in the middle grades in the Common Core State Standards for Mathematics (CCSSM). The expectation for students includes the ability to not only compute and then compare and interpret the results of computations in context but also interpret ratios and proportions as they are…

  4. Noise and LPI radar as part of counter-drone mitigation system measures

    NASA Astrophysics Data System (ADS)

    Zhang, Yan (Rockee); Huang, Yih-Ru; Thumann, Charles

    2017-05-01

    With the rapid proliferation of small unmanned aerial systems (UAS) in the national airspace, small operational drones are being sometimes considered as a security threat for critical infrastructures, such as sports stadiums, military facilities, and airports. There have been many civilian counter-drone solutions and products reported, including radar and electromagnetic counter measures. For the current electromagnetic solutions, they are usually limited to particular type of detection and counter-measure scheme, which is usually effective for the specific type of drones. Also, control and communication link technologies used in even RC drones nowadays are more sophisticated, making them more difficult to detect, decode and counter. Facing these challenges, our team proposes a "software-defined" solution based on noise and LPI radar. For the detection, wideband-noise radar has the resolution performance to discriminate possible micro-Doppler features of the drone versus biological scatterers. It also has the benefit of more adaptive to different types of drones, and covertly detecting for security application. For counter-measures, random noise can be combined with "random sweeping" jamming scheme, to achieve the optimal balance between peak power allowed and the effective jamming probabilities. Some theoretical analysis of the proposed solution is provided in this study, a design case study is developed, and initial laboratory experiments, as well as outdoor tests are conducted to validate the basic concepts and theories. The study demonstrates the basic feasibilities of the Drone Detection and Mitigation Radar (DDMR) concept, while there are still much work needs to be done for a complete and field-worthy technology development.

  5. Nudging at the checkout counter - A longitudinal study of the effect of a food repositioning nudge on healthy food choice.

    PubMed

    Van Gestel, L C; Kroese, F M; De Ridder, D T D

    2018-06-01

    Objective The current study is a longitudinal conceptual replication and aimed to investigate the effect of a food repositioning nudge on healthy food choice in a kiosk. Design During eight weeks, sales data were collected. The former four weeks formed the baseline phase and the latter four weeks formed the nudge phase where healthy food products were repositioned at the checkout counter display, while unhealthy alternatives remained available elsewhere in the store. Main Outcome Measures The main variable of interest was the proportion of healthy food products (selected to be repositioned) sold per day. Also exit interviews were administered to gather individual level data about purchases, and awareness and opinions of the nudge. Results Results showed that the proportion of selected healthy food products in total food sales was higher in all four nudge weeks than in all four baseline weeks. Individual level data showed that more customers had bought a selected healthy food product in the nudge phase and that customers generally approved of the nudge. Conclusion The current study strengthened the empirical evidence base of repositioning healthy food products as an effective and well-accepted nudge.

  6. Counter-stereotypical pictures as a strategy for overcoming spontaneous gender stereotypes.

    PubMed

    Finnegan, Eimear; Oakhill, Jane; Garnham, Alan

    2015-01-01

    The present research investigated the use of counter-stereotypical pictures as a strategy for overcoming spontaneous gender stereotypes when certain social role nouns and professional terms are read. Across two experiments, participants completed a judgment task in which they were presented with word pairs comprised of a role noun with a stereotypical gender bias (e.g., beautician) and a kinship term with definitional gender (e.g., brother). Their task was to quickly decide whether or not both terms could refer to one person. In each experiment they completed two blocks of such judgment trials separated by a training session in which they were presented with pictures of people working in gender counter-stereotypical (Experiment 1) or gender stereotypical roles (Experiment 2). To ensure participants were focused on the pictures, they were also required to answer four questions on each one relating to the character's leisure activities, earnings, job satisfaction, and personal life. Accuracy of judgments to stereotype incongruent pairings was found to improve significantly across blocks when participants were exposed to counter-stereotype images (9.87%) as opposed to stereotypical images (0.12%), while response times decreased significantly across blocks in both studies. It is concluded that exposure to counter-stereotypical pictures is a valuable strategy for overcoming spontaneous gender stereotype biases in the short term.

  7. Autism as Metaphor: Narrative and Counter-Narrative

    ERIC Educational Resources Information Center

    Broderick, Alicia A.; Ne'eman, Ari

    2008-01-01

    In this paper we explore the significance of metaphor and dominant cultural narratives in current autism discourse. We briefly explore the history of metaphor in autism discourse, and outline the contemporary struggle between the culturally dominant metaphor of autism as disease and the emergent counter-narrative of autism within neurodiversity.…

  8. University Movements as Laboratories of Counter-Hegemony

    ERIC Educational Resources Information Center

    Sotiris, Panagiotis

    2014-01-01

    Beginning with a reading of Kant's "The Conflict of the Faculties" and then moving towards a tentative possible theorization of the University as a hegemonic apparatus this paper aims at discussing university movements in terms of (counter) hegemony. Recent struggles against austerity, neoliberalism and the erosion of democracy,…

  9. Who You Callin' White?! A Critical Counter-Story on Colouring White Identity

    ERIC Educational Resources Information Center

    Matias, Cheryl E.

    2013-01-01

    This action research, which utilizes critical race theory's counter-storytelling, analyses a process of debunking White students' epistemology of ignorance in a history course at an urban public high school. After piloting a raced curriculum that deliberately re-centers marginalized counter-stories of students of colour, I document its…

  10. Mix Proportion Design of Asphalt Concrete

    NASA Astrophysics Data System (ADS)

    Wu, Xianhu; Gao, Lingling; Du, Shoujun

    2017-12-01

    Based on the gradation of AC and SMA, this paper designs a new type of anti slide mixture with two types of advantages. Chapter introduces the material selection, ratio of ore mixture ratio design calculation, and determine the optimal asphalt content test and proportioning design of asphalt concrete mix. This paper introduces the new technology of mix proportion.

  11. Quantifying Proportional Variability

    PubMed Central

    Heath, Joel P.; Borowski, Peter

    2013-01-01

    Real quantities can undergo such a wide variety of dynamics that the mean is often a meaningless reference point for measuring variability. Despite their widespread application, techniques like the Coefficient of Variation are not truly proportional and exhibit pathological properties. The non-parametric measure Proportional Variability (PV) [1] resolves these issues and provides a robust way to summarize and compare variation in quantities exhibiting diverse dynamical behaviour. Instead of being based on deviation from an average value, variation is simply quantified by comparing the numbers to each other, requiring no assumptions about central tendency or underlying statistical distributions. While PV has been introduced before and has already been applied in various contexts to population dynamics, here we present a deeper analysis of this new measure, derive analytical expressions for the PV of several general distributions and present new comparisons with the Coefficient of Variation, demonstrating cases in which PV is the more favorable measure. We show that PV provides an easily interpretable approach for measuring and comparing variation that can be generally applied throughout the sciences, from contexts ranging from stock market stability to climate variation. PMID:24386334

  12. [Use and potential risks of over-the-counter analgesics].

    PubMed

    Freytag, A; Quinzler, R; Freitag, M; Bickel, H; Fuchs, A; Hansen, H; Hoefels, S; König, H-H; Mergenthal, K; Riedel-Heller, S G; Schön, G; Weyerer, S; Wegscheider, K; Scherer, M; van den Bussche, H; Haefeli, W E; Gensichen, J

    2014-04-01

    We investigated the use of prescription and non-prescription (over-the-counter, OTC) analgesics and the associated risks in elderly patients with multiple morbidities. Pain medication use was evaluated from the baseline data (2008/2009) of the MultiCare cohort enrolling elderly patients with multiple morbidities who were treated by primary care physicians (trial registration: ISRCTN89818205). We considered opioids (N02A), other analgesics, and antipyretics (N02B) as well as nonsteroidal anti-inflammatory drugs (NSAIDs; M01A). OTC use, duplicate prescription, dosages, and interactions were examined for acetylsalicylic acid, diclofenac, (dex)ibuprofen, naproxen, and acetaminophen. Of 3,189 patients with multiple morbidities aged 65-85 years, 1,170 patients reported to have taken at least one prescription or non-prescription analgesic within the last 3 months (36.7 %). Of these, 289 patients (24.7 % of 1,170) took at least one OTC analgesic. Duplicate prescription was observed in 86 cases; 15 of these cases took the analgesics regularly. In two cases, the maximum daily dose of diclofenac was exceeded due to duplicate prescription. In 235 cases, patients concurrently took a drug with a potentially clinically relevant interaction. In 43 cases (18.3 % of 235) an OTC analgesic, usually ibuprofen, was involved. About one third of the elderly patients took analgesics regularly or as needed. Despite the relatively high use of OTC analgesics, the proportions of duplicate prescription, medication overdoses, and adverse interactions due to OTC products was low.

  13. Facile synthesis of nitrogen-doped reduced graphene oxide as an efficient counter electrode for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Wei, Liguo; Wang, Ping; Yang, Yulin; Luo, Ruidong; Li, Jinqi; Gu, Xiaohu; Zhan, Zhaoshun; Dong, Yongli; Song, Weina; Fan, Ruiqing

    2018-04-01

    A nitrogen-doped reduced graphene oxide (N-RGO) nanosheet was synthesized by a simple hydrothermal method and characterized by X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electrode microscopy. After being deposited as counter electrode film for dye-sensitized solar cells (DSSCs), it is found that the synthesized N-RGO nanosheet has smaller charge-transfer resistance and better electrocatalytic activity towards reduction of triiodide than the reduced graphene oxide (RGO) nanosheet. Consequently, the DSSCs based on the N-RGO counter electrode achieve an energy conversion efficiency of 4.26%, which is higher than that of the RGO counter electrode (2.85%) prepared under the same conditions, and comparable to the value (5.21%) obtained with the Pt counter electrode as a reference. This N-RGO counter electrode offers the advantages of not only saving the cost of Pt itself but also simplifying the process of counter electrode preparation. Therefore, an inexpensive N-RGO nanosheet is a promising counter electrode material to replace noble metal Pt. [Figure not available: see fulltext.

  14. Validation of an automated mite counter for Dermanyssus gallinae in experimental laying hen cages.

    PubMed

    Mul, Monique F; van Riel, Johan W; Meerburg, Bastiaan G; Dicke, Marcel; George, David R; Groot Koerkamp, Peter W G

    2015-08-01

    For integrated pest management (IPM) programs to be maximally effective, monitoring of the growth and decline of the pest populations is essential. Here, we present the validation results of a new automated monitoring device for the poultry red mite (Dermanyssus gallinae), a serious pest in laying hen facilities world-wide. This monitoring device (called an "automated mite counter") was validated in experimental laying hen cages with live birds and a growing population of D. gallinae. This validation study resulted in 17 data points of 'number of mites counted' by the automated mite counter and the 'number of mites present' in the experimental laying hen cages. The study demonstrated that the automated mite counter was able to track the D. gallinae population effectively. A wider evaluation showed that this automated mite counter can become a useful tool in IPM of D. gallinae in laying hen facilities.

  15. The function and response of an improved stratospheric condensation nucleus counter

    NASA Technical Reports Server (NTRS)

    Wilson, J. C.; Hyun, J. H.; Blackshear, E. D.

    1983-01-01

    An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.

  16. Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

    DTIC Science & Technology

    2015-11-01

    diesel product for ground use (1). At a minimum free water and particulate by color (as specified in the appendix of ASTM D2276) are checked daily...used in the hydraulics/hydraulic fluid industry. In 1999 ISO adopted ISO 11171 Hydraulic fluid power — Calibration of automatic particle counters...for liquids, replacing ISO 4402, as an international standard for the calibration of liquid particle counters giving NIST traceability to particle

  17. Training Post-9/11 Police Officers with a Counter-Terrorism Reality-Based Training Model: A Case Study

    ERIC Educational Resources Information Center

    Biddle, Christopher J.

    2013-01-01

    The purpose of this qualitative holistic multiple-case study was to identify the optimal theoretical approach for a Counter-Terrorism Reality-Based Training (CTRBT) model to train post-9/11 police officers to perform effectively in their counter-terrorism assignments. Post-9/11 police officers assigned to counter-terrorism duties are not trained…

  18. GENE-Counter: A Computational Pipeline for the Analysis of RNA-Seq Data for Gene Expression Differences

    PubMed Central

    Di, Yanming; Schafer, Daniel W.; Wilhelm, Larry J.; Fox, Samuel E.; Sullivan, Christopher M.; Curzon, Aron D.; Carrington, James C.; Mockler, Todd C.; Chang, Jeff H.

    2011-01-01

    GENE-counter is a complete Perl-based computational pipeline for analyzing RNA-Sequencing (RNA-Seq) data for differential gene expression. In addition to its use in studying transcriptomes of eukaryotic model organisms, GENE-counter is applicable for prokaryotes and non-model organisms without an available genome reference sequence. For alignments, GENE-counter is configured for CASHX, Bowtie, and BWA, but an end user can use any Sequence Alignment/Map (SAM)-compliant program of preference. To analyze data for differential gene expression, GENE-counter can be run with any one of three statistics packages that are based on variations of the negative binomial distribution. The default method is a new and simple statistical test we developed based on an over-parameterized version of the negative binomial distribution. GENE-counter also includes three different methods for assessing differentially expressed features for enriched gene ontology (GO) terms. Results are transparent and data are systematically stored in a MySQL relational database to facilitate additional analyses as well as quality assessment. We used next generation sequencing to generate a small-scale RNA-Seq dataset derived from the heavily studied defense response of Arabidopsis thaliana and used GENE-counter to process the data. Collectively, the support from analysis of microarrays as well as the observed and substantial overlap in results from each of the three statistics packages demonstrates that GENE-counter is well suited for handling the unique characteristics of small sample sizes and high variability in gene counts. PMID:21998647

  19. Evaluating the US Counter-ISIL Strategy

    DTIC Science & Technology

    2017-05-25

    Evaluating the US Counter-ISIL Strategy A Monograph by LTC Jason A. Curl U.S. Army School of Advanced Military Studies United States Army...SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) Advanced Straegic Leadership Studies Program 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR... studies and they use media very effectively to show the religious legitimacy of their actions. Finally, efforts to prevent the flow of ISIL supporters

  20. Application of a non-hazardous vital dye for cell counting with automated cell counters.

    PubMed

    Kim, Soo In; Kim, Hyun Jeong; Lee, Ho-Jae; Lee, Kiwon; Hong, Dongpyo; Lim, Hyunchang; Cho, Keunchang; Jung, Neoncheol; Yi, Yong Weon

    2016-01-01

    Recent advances in automated cell counters enable us to count cells more easily with consistency. However, the wide use of the traditional vital dye trypan blue (TB) raises environmental and health concerns due to its potential teratogenic effects. To avoid this chemical hazard, it is of importance to introduce an alternative non-hazardous vital dye that is compatible with automated cell counters. Erythrosin B (EB) is a vital dye that is impermeable to biological membranes and is used as a food additive. Similarly to TB, EB stains only nonviable cells with disintegrated membranes. However, EB is less popular than TB and is seldom used with automated cell counters. We found that cell counting accuracy with EB was comparable to that with TB. EB was found to be an effective dye for accurate counting of cells with different viabilities across three different automated cell counters. In contrast to TB, EB was less toxic to cultured HL-60 cells during the cell counting process. These results indicate that replacing TB with EB for use with automated cell counters will significantly reduce the hazardous risk while producing comparable results. Copyright © 2015 Logos Biosystems, Inc. Published by Elsevier Inc. All rights reserved.

  1. Compact fission counter for DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C Y; Chyzh, A; Kwan, E

    2010-11-06

    The Detector for Advanced Neutron Capture Experiments (DANCE) consists of 160 BF{sub 2} crystals with equal solid-angle coverage. DANCE is a 4{pi} {gamma}-ray calorimeter and designed to study the neutron-capture reactions on small quantities of radioactive and rare stable nuclei. These reactions are important for the radiochemistry applications and modeling the element production in stars. The recognition of capture event is made by the summed {gamma}-ray energy which is equivalent of the reaction Q-value and unique for a given capture reaction. For a selective group of actinides, where the neutron-induced fission reaction competes favorably with the neutron capture reaction, additionalmore » signature is needed to distinguish between fission and capture {gamma} rays for the DANCE measurement. This can be accomplished by introducing a detector system to tag fission fragments and thus establish a unique signature for the fission event. Once this system is implemented, one has the opportunity to study not only the capture but also fission reactions. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to {alpha} particles, which is important for experiments with {alpha}-emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. A PPAC with an ingenious design was fabricated in 2006 by integrating amplifiers into the target assembly. However, this counter was proved to be unsuitable for this application because of issues related to the stability of amplifiers and the ability to separate fission fragments from {alpha}'s. Therefore, a new design is needed. A LLNL proposal to develop a new PPAC for DANCE was funded by NA22 in FY09. The design goal is to minimize the mass for the proposed

  2. Hardware accuracy counters for application precision and quality feedback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Paula Rosa Piga, Leonardo; Majumdar, Abhinandan; Paul, Indrani

    Methods, devices, and systems for capturing an accuracy of an instruction executing on a processor. An instruction may be executed on the processor, and the accuracy of the instruction may be captured using a hardware counter circuit. The accuracy of the instruction may be captured by analyzing bits of at least one value of the instruction to determine a minimum or maximum precision datatype for representing the field, and determining whether to adjust a value of the hardware counter circuit accordingly. The representation may be output to a debugger or logfile for use by a developer, or may be outputmore » to a runtime or virtual machine to automatically adjust instruction precision or gating of portions of the processor datapath.« less

  3. Kinematic and stellar population properties of the counter-rotating components in the S0 galaxy NGC 1366

    NASA Astrophysics Data System (ADS)

    Morelli, L.; Pizzella, A.; Coccato, L.; Corsini, E. M.; Dalla Bontà, E.; Buson, L. M.; Ivanov, V. D.; Pagotto, I.; Pompei, E.; Rocco, M.

    2017-04-01

    Context. Many disk galaxies host two extended stellar components that rotate in opposite directions. The analysis of the stellar populations of the counter-rotating components provides constraints on the environmental and internal processes that drive their formation. Aims: The S0 NGC 1366 in the Fornax cluster is known to host a stellar component that is kinematically decoupled from the main body of the galaxy. Here we successfully separated the two counter-rotating stellar components to independently measure the kinematics and properties of their stellar populations. Methods: We performed a spectroscopic decomposition of the spectrum obtained along the galaxy major axis and separated the relative contribution of the two counter-rotating stellar components and of the ionized-gas component. We measured the line-strength indices of the two counter-rotating stellar components and modeled each of them with single stellar population models that account for the α/Fe overabundance. Results: We found that the counter-rotating stellar component is younger, has nearly the same metallicity, and is less α/Fe enhanced than the corotating component. Unlike most of the counter-rotating galaxies, the ionized gas detected in NGC 1366 is neither associated with the counter-rotating stellar component nor with the main galaxy body. On the contrary, it has a disordered distribution and a disturbed kinematics with multiple velocity components observed along the minor axis of the galaxy. Conclusions: The different properties of the counter-rotating stellar components and the kinematic peculiarities of the ionized gas suggest that NGC 1366 is at an intermediate stage of the acquisition process, building the counter-rotating components with some gas clouds still falling onto the galaxy. Based on observations made with ESO Telescopes at the La Silla-Paranal Observatory under programmes 075.B-0794 and 077.B-0767.

  4. Simple chemical synthesis of novel ZnO nanostructures: Role of counter ions

    NASA Astrophysics Data System (ADS)

    Pudukudy, Manoj; Yaakob, Zahira

    2014-04-01

    This article reports the synthesis, characterisation and photocatalytic activity of novel ZnO nanostructures prepared via the thermal decomposition of hydrozincite. Hydrozincites were obtained by the conventional precipitation route using different zinc salts such as acetate, nitrate, chloride and sulphate. The effect of counter ions (CH3COO-, Cl-, NO3-, and SO42-) on the structural, textural, morphological and optical properties was investigated. Various characterisations depicted the active role of counter ions in the properties of ZnO. Hexagonal wurtzite structure of ZnO with fine crystalline size was obvious from the XRD results, irrespective of the counter ions. Electron microscopic images indicated the role of counter ions in the surface and internal morphology of ZnO nanomaterials. Special coral like agglomerated morphology of elongated particles with high porosity was observed for the ZnO prepared from acetate precursor. Spherical, elongated and irregular shaped bigger lumps of ZnO nanoparticles with various novel morphologies were resulted for the sulphate, nitrate and chloride precursors respectively. Highly ordered porous micro disc like morphology was noted for the ZnO samples prepared from the sulphate and nitrate salts. Photoluminescence spectra showed the characteristic blue and green emission bands, depicting the presence of large crystal defects and high oxygen vacancies in the samples. Photocatalytic activity of the as-prepared ZnO catalysts was examined by the degradation of methylene blue under UV light irradiation. Degradation results indicated their substantial activity with respect to the counter ions. ZnO prepared from the acetate precursor showed highest photoactivity due to its high surface area, special morphology and high oxygen vacancies.

  5. Assessment of facial golden proportions among young Japanese women.

    PubMed

    Mizumoto, Yasushi; Deguchi, Toshio; Fong, Kelvin W C

    2009-08-01

    Facial proportions are of interest in orthodontics. The null hypothesis is that there is no difference in golden proportions of the soft-tissue facial balance between Japanese and white women. Facial proportions were assessed by examining photographs of 3 groups of Asian women: group 1, 30 young adult patients with a skeletal Class 1 occlusion; group 2, 30 models; and group 3, 14 popular actresses. Photographic prints or slides were digitized for image analysis. Group 1 subjects had standardized photos taken as part of their treatment. Photos of the subjects in groups 2 and 3 were collected from magazines and other sources and were of varying sizes; therefore, the output image size was not considered. The range of measurement errors was 0.17% to 1.16%. ANOVA was selected because the data set was normally distributed with homogeneous variances. The subjects in the 3 groups showed good total facial proportions. The proportions of the face-height components in group 1 were similar to the golden proportion, which indicated a longer, lower facial height and shorter nose. Group 2 differed from the golden proportion, with a short, lower facial height. Group 3 had golden proportions in all 7 measurements. The proportion of the face width deviated from the golden proportion, indicating a small mouth or wide-set eyes in groups 1 and 2. The null hypothesis was verified in the group 3 actresses in the facial height components. Some measurements in groups 1 and 2 showed different facial proportions that deviated from the golden proportion (ratio).

  6. Countering the Reactionary Federal Program for Education.

    ERIC Educational Resources Information Center

    McIntosh, Peggy

    This conference address, which originally concerned "gender issues in the schools," was modified at the last minute to contain arguments that counter and criticize a federal program for education put forth by President Ronald Reagan in a speech delivered earlier at the same conference, and the text of which is included here. The key…

  7. Developmental variation in ecogeographic body proportions.

    PubMed

    Cowgill, Libby W; Eleazer, Courtney D; Auerbach, Benjamin M; Temple, Daniel H; Okazaki, Kenji

    2012-08-01

    While ecogeographic variation in adult human body proportions has been extensively explored, relatively less attention has been paid to the effect of Bergmann's and Allen's rules on human body shape during growth. The relationship between climate and immature body form is particularly important, as immature mortality is high, mechanisms of thermoregulation differ between young and mature humans, and immature body proportions fluctuate due to basic parameters of growth. This study explores changes in immature ecogeographic body proportions via analyses of anthropometric data from children included in Eveleth and Tanner's (1976) Worldwide Variation in Human Growth, as well as limb proportion measurements in eight different skeletal samples. Moderate to strong correlations exist between climatic data and immature stature, weight, BMI, and bi-iliac breadth; these relationships are as strong, if not stronger, in immature individuals as they are in adults. Correlations between climate and trunk height relative to stature are weak or nonexistent. Altitude also has significant effects on immature body form, with children from higher altitudes displaying smaller statures and lower body weights. Brachial and crural indices remain constant over the course of growth and display consistent, moderate correlations with latitude across ontogeny that are just as high as those detected in adults. The results of this study suggest that while some features of immature body form, such as bi-iliac breadth and intralimb indices, are strongly dictated by ecogeographic principles, other characteristics of immature body proportions are influenced by intrinsic and extrinsic factors such as nutrition and basic constraints of growth. Copyright © 2012 Wiley Periodicals, Inc.

  8. COUNTER Improvised Explosive Device (C-IED) Operations as an Element of Counter Insurgency (COIN): Balancing C-IED Efforts to Support Commander International Security Assistance Force (COMISAF) Operational Objectives

    DTIC Science & Technology

    2010-10-27

    central to the enemy‟s operational design, defense and industry efforts to counter the IED with technology have been aggressive. The US has spent...and industry efforts to counter the IED with technology have been aggressive. The US has spent billions of dollars to mitigate the effects of IEDs...2001 has claimed the lives of over 1,700 United States and Coalition Force (CF) service men and women ; over six times that many have been wounded.1

  9. Retrofit designs for small bench-type blood cell counters.

    PubMed

    Ferris, C D

    1991-01-01

    This paper describes several retrofit designs to correct operational problems associated with small bench-type blood cell counters. Replacement electronic circuits as well as modifications to the vacuum systems are discussed.

  10. Counter-rotating microplates at the Galapagos triple junction.

    PubMed

    Klein, Emily M; Smith, Deborah K; Williams, Clare M; Schouten, Hans

    2005-02-24

    An 'incipient' spreading centre east of (and orthogonal to) the East Pacific Rise at 2 degrees 40' N has been identified as forming a portion of the northern boundary of the Galapagos microplate. This spreading centre was described as a slowly diverging, westward propagating rift, tapering towards the East Pacific Rise. Here we present evidence that the 'incipient rift' has also rifted towards the east and opens anticlockwise about a pivot at its eastern end. The 'incipient rift' then bounds a second microplate, north of the clockwise-rotating Galapagos microplate. The Galapagos triple junction region, in the eastern equatorial Pacific Ocean, thus consists of two counter-rotating microplates partly separated by the Hess Deep rift. Our kinematic solution for microplate motion relative to the major plates indicates that the two counter-rotating microplates may be treated as rigid blocks driven by drag on the microplates' edges3.

  11. Counter-Unmanned Aerial Vehicle Warfare: Kill Authorizations for the Carrier Strike Group

    DTIC Science & Technology

    2016-06-10

    COUNTER-UNMANNED AERIAL VEHICLE WARFARE: KILL AUTHORIZATIONS FOR THE CARRIER STRIKE GROUP A thesis presented to the Faculty...the Carrier Strike Group 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) LCDR Joshua C. Mattingly, U.S...including armed UAVs in an offensive role, but counter- UAV warfare is a new warfare area within the larger realm of air defense. Small Group 1 and 2

  12. Self-regulating neutron coincidence counter

    DOEpatents

    Baron, N.

    1980-06-16

    A device for accurately measuring the mass of /sup 240/Pu and /sup 239/Pu in a sample having arbitrary moderation and mixed with various contaminants. The device utilizes a thermal neutron well counter which has two concentric rings of neutron detectors separated by a moderating material surrounding the well. Neutron spectroscopic information derived by the two rings of detectors is used to measure the quantity of /sup 239/Pu and /sup 240/Pu in device which corrects for background radiation, deadtime losses of the detector and electronics and various other constants of the system.

  13. Thermoelectric Generation Using Counter-Flows of Ideal Fluids

    NASA Astrophysics Data System (ADS)

    Meng, Xiangning; Lu, Baiyi; Zhu, Miaoyong; Suzuki, Ryosuke O.

    2017-08-01

    Thermoelectric (TE) performance of a three-dimensional (3-D) TE module is examined by exposing it between a pair of counter-flows of ideal fluids. The ideal fluids are thermal sources of TE module flow in the opposite direction at the same flow rate and generate temperature differences on the hot and cold surfaces due to their different temperatures at the channel inlet. TE performance caused by different inlet temperatures of thermal fluids are numerically analyzed by using the finite-volume method on 3-D meshed physical models and then compared with those using a constant boundary temperature. The results show that voltage and current of the TE module increase gradually from a beginning moment to a steady flow and reach a stable value. The stable values increase with inlet temperature of the hot fluid when the inlet temperature of cold fluid is fixed. However, the time to get to the stable values is almost consistent for all the temperature differences. Moreover, the trend of TE performance using a fluid flow boundary is similar to that of using a constant boundary temperature. Furthermore, 3-D contours of fluid pressure, temperature, enthalpy, electromotive force, current density and heat flux are exhibited in order to clarify the influence of counter-flows of ideal fluids on TE generation. The current density and heat flux homogeneously distribute on an entire TE module, thus indicating that the counter-flows of thermal fluids have high potential to bring about fine performance for TE modules.

  14. Multiwire proportional chamber development

    NASA Technical Reports Server (NTRS)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  15. Counter-streaming flows in a giant quiet-Sun filament observed in the extreme ultraviolet

    NASA Astrophysics Data System (ADS)

    Diercke, A.; Kuckein, C.; Verma, M.; Denker, C.

    2018-03-01

    Aim. The giant solar filament was visible on the solar surface from 2011 November 8-23. Multiwavelength data from the Solar Dynamics Observatory (SDO) were used to examine counter-streaming flows within the spine of the filament. Methods: We use data from two SDO instruments, the Atmospheric Imaging Assembly (AIA) and the Helioseismic and Magnetic Imager (HMI), covering the whole filament, which stretched over more than half a solar diameter. Hα images from the Kanzelhöhe Solar Observatory (KSO) provide context information of where the spine of the filament is defined and the barbs are located. We apply local correlation tracking (LCT) to a two-hour time series on 2011 November 16 of the AIA images to derive horizontal flow velocities of the filament. To enhance the contrast of the AIA images, noise adaptive fuzzy equalization (NAFE) is employed, which allows us to identify and quantify counter-streaming flows in the filament. We observe the same cool filament plasma in absorption in both Hα and EUV images. Hence, the counter-streaming flows are directly related to this filament material in the spine. In addition, we use directional flow maps to highlight the counter-streaming flows. Results: We detect counter-streaming flows in the filament, which are visible in the time-lapse movies in all four examined AIA wavelength bands (λ171 Å, λ193 Å, λ304 Å, and λ211 Å). In the time-lapse movies we see that these persistent flows lasted for at least two hours, although they became less prominent towards the end of the time series. Furthermore, by applying LCT to the images we clearly determine counter-streaming flows in time series of λ171 Å and λ193 Å images. In the λ304 Å wavelength band, we only see minor indications for counter-streaming flows with LCT, while in the λ211 Å wavelength band the counter-streaming flows are not detectable with this method. The diverse morphology of the filament in Hα and EUV images is caused by different absorption

  16. ELECTRICAL PULSE COUNTER APPARATUS

    DOEpatents

    Kaufman, W.M.; Jeeves, T.A.

    1962-09-01

    A progressive electrical pulse counter circuit rs designed for the counting of a chain of input pulses. The circuit employs a series of direct connected bistable counting stages simultaneously pulsed by each input pulse and a delay means connected between each of the stages. Each bistable stage has two d-c operative states, which stage, when in its initial state, prevents the next succeeding stage from changing its condition when the latter stage is pulsed. Since the delay circuits between the stages prevents the immediate decay of the d-c state of each stage when the stages are pulsed, only one stage will change its state for each input pulse, thereby providing progressive stage-by-stage counting. (AEC)

  17. Average-passage simulation of counter-rotating propfan propulsion systems as applied to cruise missiles

    NASA Technical Reports Server (NTRS)

    Mulac, Richard A.; Schneider, Jon C.; Adamczyk, John J.

    1989-01-01

    Counter-rotating propfan (CRP) propulsion technologies are currently being evaluated as cruise missile propulsion systems. The aerodynamic integration concerns associated with this application are being addressed through the computational modeling of the missile body-propfan flowfield interactions. The work described in this paper consists of a detailed analysis of the aerodynamic interactions between the control surfaces and the propfan blades through the solution of the average-passage equation system. Two baseline configurations were studied, the control fins mounted forward of the counter-rotating propeller and the control fins mounted aft of the counter-rotating propeller. In both cases, control fin-propfan separation distance and control fin deflection angle were varied.

  18. A bismuth activation counter for high sensitivity pulsed 14 MeV neutrons

    NASA Astrophysics Data System (ADS)

    Burns, E. J. T.; Thacher, P. D.; Hassig, G. J.; Decker, R. D.; Romero, J. A.; Barrett, K. P.

    2011-08-01

    We have built a fast neutron bismuth activation counter that measures activation counts from pulsed 14-MeV neutron generators for incident neutron fluences between 30 and 300 neutrons/cm2 at 15.2 cm (6 in.). The activation counter consists of a large bismuth germanate (BGO) detector surrounded by a bismuth metal shield in front of and concentric with the cylindrical detector housing. The 14 MeV neutrons activate the 2.6-millisecond (ms) isomer in the shield and the detector by the reaction 209Bi (n,2nγ) 208mBi. The use of millisecond isomers and activation counting times minimizes the background from other activated materials and the environment. In addition to activation, the bismuth metal shields against other outside radiation sources. We have tested the bismuth activation counter, simultaneously, with two data acquisition systems (DASs) and both give similar results. The two-dimensional (2D) DAS and three dimensional (3D) DAS both consist of pulse height analysis (PHA) systems that can be used to discriminate against gamma radiations below 300 keV photon energy, so that the detector can be used strictly as a counter. If the counting time is restricted to less than 25 ms after the neutron pulse, there are less than 10 counts of background for single pulse operation in all our operational environments tested so far. High-fluence neutron generator operations are restricted by large dead times and pulse height saturation. When we operate our 3D DAS PHA system in list mode acquisition (LIST), real-time corrections to dead time or live time can be made on the scale of 1 ms time windows or dwell times. The live time correction is consistent with nonparalyzable models for dead time of 1.0±0.2 μs for our 3D DAS and 1.5±0.3 μs for our 2D DAS dominated by our fixed time width analog to digital converters (ADCs). With the same solid angle, we have shown that the bismuth activation counter has a factor of 4 increase in sensitivity over our lead activation counter

  19. Monte Carlo simulations of safeguards neutron counter for oxide reduction process feed material

    NASA Astrophysics Data System (ADS)

    Seo, Hee; Lee, Chaehun; Oh, Jong-Myeong; An, Su Jung; Ahn, Seong-Kyu; Park, Se-Hwan; Ku, Jeong-Hoe

    2016-10-01

    One of the options for spent-fuel management in Korea is pyroprocessing whose main process flow is the head-end process followed by oxide reduction, electrorefining, and electrowining. In the present study, a well-type passive neutron coincidence counter, namely, the ACP (Advanced spent fuel Conditioning Process) safeguards neutron counter (ASNC), was redesigned for safeguards of a hot-cell facility related to the oxide reduction process. To this end, first, the isotopic composition, gamma/neutron emission yield and energy spectrum of the feed material ( i.e., the UO2 porous pellet) were calculated using the OrigenARP code. Then, the proper thickness of the gammaray shield was determined, both by irradiation testing at a standard dosimetry laboratory and by MCNP6 simulations using the parameters obtained from the OrigenARP calculation. Finally, the neutron coincidence counter's calibration curve for 100- to 1000-g porous pellets, in consideration of the process batch size, was determined through simulations. Based on these simulation results, the neutron counter currently is under construction. In the near future, it will be installed in a hot cell and tested with spent fuel materials.

  20. The Origins of Scintillator Non-Proportionality

    NASA Astrophysics Data System (ADS)

    Moses, W. W.; Bizarri, G. A.; Williams, R. T.; Payne, S. A.; Vasil'ev, A. N.; Singh, J.; Li, Q.; Grim, J. Q.; Choong, W.-S.

    2012-10-01

    Recent years have seen significant advances in both theoretically understanding and mathematically modeling the underlying causes of scintillator non-proportionality. The core cause is that the interaction of radiation with matter invariably leads to a non-uniform ionization density in the scintillator, coupled with the fact that the light yield depends on the ionization density. The mechanisms that lead to the luminescence dependence on ionization density are incompletely understood, but several important features have been identified, notably Auger-like processes (where two carriers of excitation interact with each other, causing one to de-excite non-radiatively), the inability of excitation carriers to recombine (caused either by trapping or physical separation), and the carrier mobility. This paper reviews the present understanding of the fundamental origins of scintillator non-proportionality, specifically the various theories that have been used to explain non-proportionality.

  1. Potential public sector cost-savings from over-the-counter access to oral contraceptives.

    PubMed

    Foster, Diana G; Biggs, M Antonia; Phillips, Kathryn A; Grindlay, Kate; Grossman, Daniel

    2015-05-01

    This study estimates how making oral contraceptive pills (OCPs) available without a prescription may affect contraceptive use, unintended pregnancies and associated contraceptive and pregnancy costs among low-income women. Based on published figures, we estimate two scenarios [low over-the-counter (OTC) use and high OTC use] of the proportion of low-income women likely to switch to an OTC pill and predict adoption of OCPs according to the out-of-pocket costs per pill pack. We then estimate cost-savings of each scenario by comparing the total public sector cost of providing OCPs OTC and medical care for unintended pregnancy. Twenty-one percent of low-income women at risk for unintended pregnancy are very likely to use OCPs if they were available without a prescription. Women's use of OTC OCPs varies widely by the out-of-pocket pill pack cost. In a scenario assuming no out-of-pocket costs for the over-the counter pill, an additional 11-21% of low-income women will use the pill, resulting in a 20-36% decrease in the number of women using no method or a method less effective than the pill, and a 7-25% decrease in the number of unintended pregnancies, depending on the level of use and any effect on contraceptive failure rates. If out-of-pocket costs for such pills are low, OTC access could have a significant effect on use of effective contraceptives and unintended pregnancy. Public health plans may reduce expenditures on pregnancy and contraceptive healthcare services by covering oral contraceptives as an OTC product. Interest in OTC access to oral contraceptives is high. Removing the prescription barrier, particularly if pill packs are available at low or zero out-of-pocket cost, could increase the use of effective methods of contraception and reduce unintended pregnancy and healthcare costs for contraceptive and pregnancy care. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  3. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  4. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  5. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  6. Keep It in Proportion.

    ERIC Educational Resources Information Center

    Snider, Richard G.

    1985-01-01

    The ratio factors approach involves recognizing a given fraction, then multiplying so that units cancel. This approach, which is grounded in concrete operational thinking patterns, provides a standard for science ratio and proportion problems. Examples are included for unit conversions, mole problems, molarity, speed/density problems, and…

  7. Transference, Counter-Transference, and Reflexivity in Intercultural Education

    ERIC Educational Resources Information Center

    Shim, Jenna Min

    2015-01-01

    The article addresses the contributions psychoanalytic theory, particularly its concepts of "transference and counter-transference," can make to our understanding of reflexivity in intercultural education (IE). After the introduction, the article is organized into three parts. The first part is a psychoanalytic discussion that focuses on…

  8. Masked Proportional Routing

    NASA Technical Reports Server (NTRS)

    Wolpert, David

    2004-01-01

    Masked proportional routing is an improved procedure for choosing links between adjacent nodes of a network for the purpose of transporting an entity from a source node ("A") to a destination node ("B"). The entity could be, for example, a physical object to be shipped, in which case the nodes would represent waypoints and the links would represent roads or other paths between waypoints. For another example, the entity could be a message or packet of data to be transmitted from A to B, in which case the nodes could be computer-controlled switching stations and the links could be communication channels between the stations. In yet another example, an entity could represent a workpiece while links and nodes could represent, respectively, manufacturing processes and stages in the progress of the workpiece towards a finished product. More generally, the nodes could represent states of an entity and the links could represent allowed transitions of the entity. The purpose of masked proportional routing and of related prior routing procedures is to schedule transitions of entities from their initial states ("A") to their final states ("B") in such a manner as to minimize a cost or to attain some other measure of optimality or efficiency. Masked proportional routing follows a distributed (in the sense of decentralized) approach to probabilistically or deterministically choosing the links. It was developed to satisfy a need for a routing procedure that 1. Does not always choose the same link(s), even for two instances characterized by identical estimated values of associated cost functions; 2. Enables a graceful transition from one set of links to another set of links as the circumstances of operation of the network change over time; 3. Is preferably amenable to separate optimization of different portions of the network; 4. Is preferably usable in a network in which some of the routing decisions are made by one or more other procedure(s); 5. Preferably does not cause an

  9. Can counter-advertising reduce pre-adolescent children's susceptibility to front-of-package promotions on unhealthy foods? Experimental research.

    PubMed

    Dixon, Helen; Scully, Maree; Kelly, Bridget; Chapman, Kathy; Wakefield, Melanie

    2014-09-01

    This study aimed to test whether counter-advertisements (i.e. messages contesting industry marketing) make pre-adolescent children less susceptible to the influence of food promotions. Since children have lower media literacy levels due to their immature cognitive abilities, specific research questions explored were: (1) whether the effectiveness of counter-ads is contingent on children having understood them; and (2) whether counter-ads may be detrimental when they are misinterpreted. A between-subjects experimental design using a web-based methodology was employed. 1351 grade 5-6 students (mean age 11 years) from schools located in metropolitan Melbourne, Australia participated. Participants were randomly shown an animated web banner advertisement (counter-ad challenging front-of-package promotion or control ad) and a pair of food packages from the same product category comprising an unhealthy product featuring a front-of-package promotion (nutrient content claim or sports celebrity endorsement) and a healthier control pack without a front-of-package promotion. Responses to the assigned advertisement, choice of product (healthy versus unhealthy) and ratings of the unhealthy product and front-of-package promotion on various nutritional and image-related attributes were recorded for each child. Sixty-six percent of children who viewed a counter-ad understood its main message. These children rated the front-of-package promotion as less believable and rated the unhealthy product bearing the front-of-package promotion as less healthy compared to the control group. However, children who misunderstood the counter-ad rated the unhealthy product bearing a front-of-package promotion as more healthy and rated the front-of-package promotion more favourably than those who correctly understood the counter-ad. Counter-advertising may have unintended consequences when misunderstood. If public health organizations or government pursue counter-advertising as a strategy to reduce

  10. Gold nanoparticle decorated multi-walled carbon nanotubes as counter electrode for dye sensitized solar cells.

    PubMed

    Kaniyoor, Adarsh; Ramaprabhu, Sundara

    2012-11-01

    A novel counter electrode material for dye sensitized solar cells (DSSCs) composed of nanostructured Au particles decorated on functionalized multi-walled carbon nanotubes (f-MWNTs) is demonstrated for the first time. MWNTs synthesized by catalytic chemical vapor deposition technique are purified and functionalized by treating with concentrated acids. Au nanoparticles are decorated on f-MWNTs by a rapid and facile microwave assisted polyol reduction method. The materials are characterized by X-ray diffractometry, Fourier transform infra red spectroscopy and electron microscopy. The DSSC fabricated with Au/f-MWNTs based counter electrode shows enhanced power conversion efficiency (eta) of 4.9% under AM 1.5G simulated solar radiation. In comparison, the reference DSSCs fabricated with f-MWNTs and Pt counter electrodes show eta of 2.1% and 4.5%. This high performance of Au/f-MWNTs counter electrode is investigated using electrochemical impedance spectroscopy and cyclic voltammetry studies.

  11. 16 CFR 240.9 - Proportionally equal terms.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Proportionally equal terms. 240.9 Section 240.9 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR ADVERTISING ALLOWANCES AND OTHER MERCHANDISING PAYMENTS AND SERVICES § 240.9 Proportionally equal terms. (a...

  12. Evaluation of the Benjamin type proportional counter for absolute neutron spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taeb, M.

    1985-01-01

    This evaluation has shown that the major sources of uncertainty in experimental measurements with a Benjamin detector are: (1) detector pressure, (2) hydrogen gas purity, (3) detector calibration, and (4) operating voltage. To test these operational parameters, neutron spectra were measured at the University of Missouri Research Reactor (MURR) for silicon, scandium, iron, and bismuth filtered beams and angular penetration data through an 20.3 cm water slab. Results were then critically compared with theoretical calculations and with data from other spectrometer systems in regions of energy overlap. Neutron spectra having relatively small contributions from neutrons with energies higher than themore » energy range of the Benjamin spectrometer (at a specific pressure) generally exhibit excellent results. This is particularly true for the silicon filter (which produces two quasi-monoenergetic peaks at 55 keV and 144 keV) and the scandium filter (which creates a spectrum which decreases with increasing energy). For those spectra exhibiting relatively larger high energy neutron components, the results are less satisfying.« less

  13. Proportionality, just war theory and weapons innovation.

    PubMed

    Forge, John

    2009-03-01

    Just wars are supposed to be proportional responses to aggression: the costs of war must not greatly exceed the benefits. This proportionality principle raises a corresponding 'interpretation problem': what are the costs and benefits of war, how are they to be determined, and a 'measurement problem': how are costs and benefits to be balanced? And it raises a problem about scope: how far into the future do the states of affairs to be measured stretch? It is argued here that weapons innovation always introduces costs, and that these costs cannot be determined in advance of going to war. Three examples, the atomic bomb, the AK-47 and the ancient Greek catapult, are given as examples. It is therefore argued that the proportionality principle is inapplicable prospectively. Some replies to the argument are discussed and rejected. Some more general defences of the proportionality principle are considered and also rejected. Finally, the significance of the argument for Just War Theory as a whole is discussed.

  14. The difference in age of the two counter-rotating stellar disks of the spiral galaxy NGC 4138

    NASA Astrophysics Data System (ADS)

    Pizzella, A.; Morelli, L.; Corsini, E. M.; Dalla Bontà, E.; Coccato, L.; Sanjana, G.

    2014-10-01

    Context. Galaxies accrete material from the environment through acquisitions and mergers. These processes contribute to the galaxy assembly and leave their fingerprints on the galactic morphology, internal kinematics of gas and stars, and stellar populations. Aims: The Sa spiral NGC 4138 is known to host two counter-rotating stellar disks, with the ionized gas co-rotating with one of them. We measured the kinematics and properties of the two counter-rotating stellar populations to constrain their formation scenario. Methods: A spectroscopic decomposition of the observed major-axis spectrum was performed to disentangle the relative contribution of the two counter-rotating stellar and one ionized-gas components. The line-strength indices of the two counter-rotating stellar components were measured and modeled with single stellar population models that account for the α/Fe overabundance. Results: The counter-rotating stellar population is younger, marginally more metal poor, and more α-enhanced than the main stellar component. The younger stellar component is also associated with a star-forming ring. Conclusions: The different properties of the counter-rotating stellar components of NGC 4138 rule out the idea that they formed because of bar dissolution. Our findings support the results of numerical simulations in which the counter-rotating component assembled from gas accreted on retrograde orbits from the environment or from the retrograde merging with a gas-rich dwarf galaxy. Based on observation carried out at the Galileo 1.22 m telescope at Padua University.

  15. Superconducting analog-to-digital converter with a triple-junction reversible flip-flop bidirectional counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, G.S.

    1993-07-13

    A high-performance superconducting analog-to-digital converter is described, comprising: a bidirectional binary counter having n stages of triple-junction reversible flip-flops connected together in a cascade arrangement from the least significant bit (LSB) to the most significant bit (MSB) where n is the number of bits of the digital output, each triple-junction reversible flip-flop including first, second and third shunted Josephson tunnel junctions and a superconducting inductor connected in a bridge circuit, the Josephson junctions and the inductor forming upper and lower portions of the flip-flop, each reversible flip-flop being a bistable logic circuit in which the direction of the circulating currentmore » determines the state of the circuit; and means for applying an analog input current to the bidirectional counter; wherein the bidirectional counter algebraically counts incremental changes in the analog input current, increasing the binary count for positive incremental changes in the analog current and decreasing the binary count for negative incremental changes in the current, and wherein the counter does not require a gate bias, thus minimizing power dissipation.« less

  16. Counter Synthesis: A Critical Approach to Social Movements.

    ERIC Educational Resources Information Center

    Harral, Harriet Briscoe

    Modern society is an ever-changing pattern of pressure and counter pressure. A social movement in conflict with the dominant society is labeled with easily identifiable stereotypes--bearded long hairs, bra burners, terrorists, bleeding hearts, uneducated rednecks. Traditional criticism has failed to say anything meaningful about social movements…

  17. Construction of silica aerogel radiator system for Belle II RICH Counter

    NASA Astrophysics Data System (ADS)

    Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    We have developed a RICH counter as a new forward particle identification device for the Belle II experiment. As a Cherenkov radiator in this counter, a dual aerogel layer combination consisting of two refractive indicies, n=1.045 and 1.055, is employed. Mass production of these aerogel tiles has been done during 2013-2014 with new method improved by Chiba group. Optical qualities for them have been examined. The refractive indices of the obtained tiles were found to be in good agreement with our expectations, and the transparencies were high enough to be used for the RICH radiator.

  18. Cross counter-based adaptive assembly scheme in optical burst switching networks

    NASA Astrophysics Data System (ADS)

    Zhu, Zhi-jun; Dong, Wen; Le, Zi-chun; Chen, Wan-jun; Sun, Xingshu

    2009-11-01

    A novel adaptive assembly algorithm called Cross-counter Balance Adaptive Assembly Period (CBAAP) is proposed in this paper. The major difference between CBAAP and other adaptive assembly algorithms is that the threshold of CBAAP can be dynamically adjusted according to the cross counter and step length value. In terms of assembly period and the burst loss probability, we compare the performance of CBAAP with those of three typical algorithms FAP (Fixed Assembly Period), FBL (Fixed Burst Length) and MBMAP (Min-Burst length-Max-Assembly-Period) in the simulation part. The simulation results demonstrate the effectiveness of our algorithm.

  19. Effect of counter-pulsation control of a pulsatile left ventricular assist device on working load variations of the native heart.

    PubMed

    Choi, Seong Wook; Nam, Kyoung Won; Lim, Ki Moo; Shim, Eun Bo; Won, Yong Soon; Woo, Heung Myong; Kwak, Ho Hyun; Noh, Mi Ryoung; Kim, In Young; Park, Sung Min

    2014-04-03

    When using a pulsatile left ventricular assist device (LVAD), it is important to reduce the cardiac load variations of the native heart because severe cardiac load variations can induce ventricular arrhythmia. In this study, we investigated the effect of counter-pulsation control of the LVAD on the reduction of cardiac load variation. A ventricular electrocardiogram-based counter-pulsation control algorithm for a LVAD was implemented, and the effects of counter-pulsation control of the LVAD on the reduction of the working load variations of the left ventricle were determined in three animal experiments. Deviations of the working load of the left ventricle were reduced by 51.3%, 67.9%, and 71.5% in each case, and the beat-to-beat variation rates in the working load were reduced by 84.8%, 82.7%, and 88.2% in each ease after counter-pulsation control. There were 3 to 12 premature ventricle contractions (PVCs) before counter-pulsation control, but no PVCs were observed during counter-pulsation control. Counter-pulsation control of the pulsatile LVAD can reduce severe cardiac load variations, but the average working load is not markedly affected by application of counter-pulsation control because it is also influenced by temporary cardiac outflow variations. We believe that counter-pulsation control of the LVAD can improve the long-term safety of heart failure patients equipped with LVADs.

  20. Proportioning Cats and Rats

    ERIC Educational Resources Information Center

    Markworth, Kimberly A.

    2012-01-01

    Students may be able to set up a relevant proportion and solve through cross multiplication. However, this ability may not reflect the desired mathematical understanding of the covarying relationship that exists between two variables or the equivalent relationship that exists between two ratios. Students who lack this understanding are likely to…

  1. The relative effectiveness of extinction and counter-conditioning in diminishing children's fear.

    PubMed

    Newall, Carol; Watson, Tiffany; Grant, Kerry-Ann; Richardson, Rick

    2017-08-01

    Two behavioural strategies for reducing learned fear are extinction and counter-conditioning, and in this study we compared the relative effectiveness of the two procedures at diminishing fear in children. Seventy-three children aged 7-12 years old (M = 9.30, SD = 1.62) were exposed to pictures of two novel animals on a computer screen during the fear acquisition phase. One of these animals was paired with a picture of a scared human face (CS+) while the other was not (CS-). The children were then randomly assigned to one of three conditions: counter-conditioning (animal paired with a happy face), extinction (animal without scared face), or control (no fear reduction procedure). Changes in fear beliefs and behavioural avoidance of the animal were measured. Counter-conditioning was more effective at reducing fear to the CS + than extinction. The findings are discussed in terms of implications for behavioural treatments of childhood anxiety disorders. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  2. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  3. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear whole body counter. 892.1130 Section 892.1130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... entire body. This generic type of device may include signal analysis and display equipment, patient and...

  4. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nuclear whole body counter. 892.1130 Section 892.1130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... entire body. This generic type of device may include signal analysis and display equipment, patient and...

  5. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nuclear whole body counter. 892.1130 Section 892.1130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... entire body. This generic type of device may include signal analysis and display equipment, patient and...

  6. Highly effective carbon sphere counter electrodes based on different substrates for dye-sensitized solar cell.

    PubMed

    Han, Qianji; Wang, Hongrui; Liu, Yali; Yan, Yajing; Wu, Mingxing

    2017-11-15

    A monodisperse carbon sphere with high uniformity, high catalytic activity and conductivity are successfully synthesized. Versatile counter electrodes using this carbon sphere catalyst on different substrates of fluorine-doped tin oxide (FTO) glass, indium-doped tin oxide polyethylenena phthalate (ITO-PEN), and Ti foil are fabricated for dye-sensitized solar cell (DSC). The impacts of substrates on the catalytic activities of the carbon sphere counter electrodes have been also evaluated by electrochemical analysis technologies, such as cyclic voltammetry, electrochemical impedance spectroscopy and Tafel polarization curves. With cobalt electrolyte, the DSC using carbon sphere counter electrodes based on FTO glass, ITO-PEN, and Ti substrates yield high power conversion efficiency values of 8.57%, 6.66%, and 9.10%, respectively. The catalytic activities of the prepared carbon sphere counter electrodes on different substrates are determined by the apparent activation energy for the cobalt redox couple regeneration on these electrodes. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Contingency proportion systematically influences contingency learning.

    PubMed

    Forrin, Noah D; MacLeod, Colin M

    2018-01-01

    In the color-word contingency learning paradigm, each word appears more often in one color (high contingency) than in the other colors (low contingency). Shortly after beginning the task, color identification responses become faster on the high-contingency trials than on the low-contingency trials-the contingency learning effect. Across five groups, we varied the high-contingency proportion in 10% steps, from 80% to 40%. The size of the contingency learning effect was positively related to high-contingency proportion, with the effect disappearing when high contingency was reduced to 40%. At the two highest contingency proportions, the magnitude of the effect increased over trials, the pattern suggesting that there was an increasing cost for the low-contingency trials rather than an increasing benefit for the high-contingency trials. Overall, the results fit a modified version of Schmidt's (2013, Acta Psychologica, 142, 119-126) parallel episodic processing account in which prior trial instances are routinely retrieved from memory and influence current trial performance.

  8. Understanding Proportional Reasoning in Pre-Service Teachers

    ERIC Educational Resources Information Center

    Johnson, Kim H.

    2013-01-01

    The purpose of this study is to examine the proportional reasoning of pre-service teachers at the beginning of their teacher preparation program using the developmental shifts described by Lobato and Ellis (2010). They cast changes in proportional reasoning as transitions or "shifts" in students' thinking and these shifts can serve as…

  9. Working Memory Mechanism in Proportional Quantifier Verification

    ERIC Educational Resources Information Center

    Zajenkowski, Marcin; Szymanik, Jakub; Garraffa, Maria

    2014-01-01

    The paper explores the cognitive mechanisms involved in the verification of sentences with proportional quantifiers (e.g. "More than half of the dots are blue"). The first study shows that the verification of proportional sentences is more demanding than the verification of sentences such as: "There are seven blue and eight yellow…

  10. Engineered porous silicon counter electrodes for high efficiency dye-sensitized solar cells.

    PubMed

    Erwin, William R; Oakes, Landon; Chatterjee, Shahana; Zarick, Holly F; Pint, Cary L; Bardhan, Rizia

    2014-06-25

    In this work, we demonstrate for the first time, the use of porous silicon (P-Si) as counter electrodes in dye-sensitized solar cells (DSSCs) with efficiencies (5.38%) comparable to that achieved with platinum counter electrodes (5.80%). To activate the P-Si for triiodide reduction, few layer carbon passivation is utilized to enable electrochemical stability of the silicon surface. Our results suggest porous silicon as a promising sustainable and manufacturable alternative to rare metals for electrochemical solar cells, following appropriate surface modification.

  11. As-built design specification for proportion estimate software subsystem

    NASA Technical Reports Server (NTRS)

    Obrien, S. (Principal Investigator)

    1980-01-01

    The Proportion Estimate Processor evaluates four estimation techniques in order to get an improved estimate of the proportion of a scene that is planted in a selected crop. The four techniques to be evaluated were provided by the techniques development section and are: (1) random sampling; (2) proportional allocation, relative count estimate; (3) proportional allocation, Bayesian estimate; and (4) sequential Bayesian allocation. The user is given two options for computation of the estimated mean square error. These are referred to as the cluster calculation option and the segment calculation option. The software for the Proportion Estimate Processor is operational on the IBM 3031 computer.

  12. Countering A2/AD with Swarming

    DTIC Science & Technology

    2016-04-01

    to prevent the U.S. from being able to fight such a war. Rather, the adversaries have adopted A2/AD strategies that would force the U.S. to fight an...undesirable war of attrition in order to achieve their objective. The current strategy to counter A2/AD is a strategy that forces the tenets of an...annihilation strategy into the context of an attrition environment. The result is that it weakens the military as an instrument of national power. The

  13. Pay for Play. Countering Threat Financing

    DTIC Science & Technology

    2010-01-01

    ndupress .ndu.edu issue 56, 1 st quarter 2010 / JFQ 123 Pay for Play Countering Threat Financing By m i c h a e l t . F l y n n and s i m o n...dis- covered that illicit financing networks repre- sent both a significant strength and a critical enemy vulnerability to exploit. Guns, drugs...weapons of mass destruction, and humans are all commodities interactively traded by terror- ists in corporate -like networks. As we have discovered

  14. Body load in heel-strike running: the effect of a firm heel counter.

    PubMed

    Jørgensen, U

    1990-01-01

    The effect of a firm heel counter in the shoe was studied in 11 athletes during submaximal heel-strike running on a treadmill under standardized conditions. The runners were tested in identical shoes with and without the distal 2 cm of the firm heel counter. Body load was expressed by absolute and relative VO2, surface EMG on the right leg, and g-force registration from an accelerometer below the right tibial tuberosity. The heel counter caused a 2.4% significant decrease in VO2, a reduction in musculoskeletal transients, and a decrease in the activity of the triceps surae and quadriceps muscles at heel strike. The changes found are expressions of kinematic adaptations in the body to increased or decreased load and provide functional evidence for the loading factor in the pathophysiology of overuse injuries.

  15. Against proportional shortfall as a priority-setting principle.

    PubMed

    Altmann, Samuel

    2018-05-01

    As the demand for healthcare rises, so does the need for priority setting in healthcare. In this paper, I consider a prominent priority-setting principle: proportional shortfall. My purpose is to argue that proportional shortfall, as a principle, should not be adopted. My key criticism is that proportional shortfall fails to consider past health.Proportional shortfall is justified as it supposedly balances concern for prospective health while still accounting for lifetime health, even though past health is deemed irrelevant. Accounting for this lifetime perspective means that the principle may indirectly consider past health by accounting for how far an individual is from achieving a complete, healthy life. I argue that proportional shortfall does not account for this lifetime perspective as it fails to incorporate the fair innings argument as originally claimed, undermining its purported justification.I go on to demonstrate that the case for ignoring past health is weak, and argue that past health is at least sometimes relevant for priority-setting decisions. Specifically, when an individual's past health has a direct impact on current or future health, and when one individual has enjoyed significantly more healthy life years than another.Finally, I demonstrate that by ignoring past illnesses, even those entirely unrelated to their current illness, proportional shortfall can lead to instances of double jeopardy, a highly problematic implication. These arguments give us reason to reject proportional shortfall. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Modelling Proportional Thinking with Threes and Twos

    ERIC Educational Resources Information Center

    Tabart, Paul; Skalicky, Jane; Watson, Jane

    2005-01-01

    The authors discuss proportional reasoning as a challenging yet central concept for students in the middle grades that lays a foundation for mathematics studied later in high school. Four types of proportional reasoning problems are discussed: (1) Part-part-whole (comparing a subset (part) of a whole with its complement (other part) or the whole…

  17. INTERIOR OF THE WORKSHOP, LOOKING SOUTH. (On the counter of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF THE WORKSHOP, LOOKING SOUTH. (On the counter of the workshop are instructions and supplies for artificially inseminating pigs.) - Jenne Farm, Workshop, 538 Engle Road, Coupeville, Island County, WA

  18. Nonlinear Effects in Transformation Optics-Based Metamaterial Shields for Counter Directed Energy Weapon Defense

    DTIC Science & Technology

    2016-06-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS NONLINEAR EFFECTS IN TRANSFORMATION OPTICS-BASED METAMATERIAL SHIELDS FOR COUNTER DIRECTED...2014 to 06-17-2016 4. TITLE AND SUBTITLE NONLINEAR EFFECTS IN TRANSFORMATION OPTICS-BASED METAMATE- RIAL SHIELDS FOR COUNTER DIRECTED ENERGY WEAPON...and magnetization fields with respect to incident electromagnetic field intensities. As those field intensities rise, such as from a hypothetical

  19. The Efficacy of Foreign Assistance in Counter Narcotics

    DTIC Science & Technology

    2013-03-01

    Crop Reduction Components)...................................................................................25 Table 6. Colombian Coffee Prices in U.S...Colombia was initiated by the Clinton administration to assist the Colombian government with counter-narcotics, governing capacity, and economic...Assistance, Sustainable Development, and the War on Terrorism (Washington, D.C.: Environmental Law Institute, 2002) 8; Jean-Paul Azam and Veronique

  20. Validity of the Bite Counter device in a controlled laboratory setting.

    PubMed

    Desendorf, Jenna; Bassett, David R; Raynor, Hollie A; Coe, Dawn P

    2014-08-01

    Body-borne sensors may be useful in assessing eating behaviors and have the potential to overcome some of the limitations of self-report instruments. The Bite Counter is a new commercial device, worn on the wrist that purports to track the number of bites taken per day. It contains a tri-axial accelerometer that detects an upward, arcing motion from the table to the mouth, known as a wrist roll. To examine the validity of the Bite Counter device for measuring bites in individuals while consuming various foods and beverages. 15 adults (23-58 years old) wore the device on the wrist of their dominant hand. They were presented with a meal consisting of foods/beverages, each consumed with different utensils: meat (knife and fork), side items (fork), soup (spoon), pizza (hands), can of soda (hands), and a smoothie (straw). Each food or drink was consumed by itself, in consecutive order. A researcher observed them through a one-way mirror and counted the number of bites taken. The percentage of actual bites taken varied as follows: Meat (127%), side items (82.6%), soup (60.2%), pizza (87.3%), soda (81.7%), and smoothie (57.7%). The overall mean was 81.2% of bites taken. The results indicate that the Bite Counter holds promise for being able to count the number of hand-to-mouth movements. In general, it underestimated hand-to-mouth movements, but some types of hand movements caused overestimation of bites. Future studies should be undertaken to improve the sensitivity and specificity of the Bite Counter device. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. The effect of thermal neutron field slagging caused by cylindrical BF3 counters in diffusion media

    NASA Technical Reports Server (NTRS)

    Gorshkov, G. V.; Tsvetkov, O. S.; Yakovlev, R. M.

    1975-01-01

    Computations are carried out in transport approximation (first collision method) for the attenuation of the field of thermal neutrons formed in counters of the CHM-8 and CHMO-5 type. The deflection of the thermal neutron field is also obtained near the counters and in the air (shade effect) and in various decelerating media (water, paraffin, plexiglas) for which the calculations are carried out on the basis of diffusion theory. To verify the calculations, the distribution of the density of the thermal neutrons at various distances from the counter in the water is measured.

  2. Sensor noise camera identification: countering counter-forensics

    NASA Astrophysics Data System (ADS)

    Goljan, Miroslav; Fridrich, Jessica; Chen, Mo

    2010-01-01

    In camera identification using sensor noise, the camera that took a given image can be determined with high certainty by establishing the presence of the camera's sensor fingerprint in the image. In this paper, we develop methods to reveal counter-forensic activities in which an attacker estimates the camera fingerprint from a set of images and pastes it onto an image from a different camera with the intent to introduce a false alarm and, in doing so, frame an innocent victim. We start by classifying different scenarios based on the sophistication of the attacker's activity and the means available to her and to the victim, who wishes to defend herself. The key observation is that at least some of the images that were used by the attacker to estimate the fake fingerprint will likely be available to the victim as well. We describe the socalled "triangle test" that helps the victim reveal attacker's malicious activity with high certainty under a wide range of conditions. This test is then extended to the case when none of the images that the attacker used to create the fake fingerprint are available to the victim but the victim has at least two forged images to analyze. We demonstrate the test's performance experimentally and investigate its limitations. The conclusion that can be made from this study is that planting a sensor fingerprint in an image without leaving a trace is significantly more difficult than previously thought.

  3. High use of over-the-counter analgesic; possible warnings of reduced quality of life in adolescents - a qualitative study.

    PubMed

    Skarstein, Siv; Lagerløv, Per; Kvarme, Lisbeth Gravdal; Helseth, Sølvi

    2016-01-01

    Use of over-the-counter analgesics among adolescents has increased markedly. High consumption of over-the-counter analgesics among adolescents is associated with frequent pain, lower self-esteem, reduced sleep, lower educational ambition, binge drinking, higher caffeine consumption, and part-time employment. Knowledge about life experiences of adolescents who frequently use over-the-counter analgesics may be useful to prevent health problems. The purpose of the study was to increase knowledge about adolescents who suffer from frequent pain and have a high consumption of over-the-counter analgesics. A qualitative study, employing one-on-one, in-depth interviews using a thematic interview guide. Data were collected in Norway in 2013-2014. Three boys and sixteen girls; aged 14-16 years, who continuously consumed over-the-counter analgesics were recruited from ten high schools in urban and suburban districts. Candidate participants were excluded if they were medically diagnosed with an acute or chronic illness, requiring extended use of over-the-counter analgesics within the last year. The interviews were taped, transcribed and analysed as text according to Kvale's three contexts of interpretation: self-understanding, common sense and theory. All participants disclosed unresolved physical and psychosocial distress characterized as pain. Frequent pain from various body parts made everyday life challenging. Methods of pain self-appraisal and over-the-counter analgesics use often mimicked maternal patterns. Participants reported being raised under unpredictable circumstances that contributed to long lasting family conflicts and peer-group problems. Participants wanted to feel appreciated and to be socially and academically successful. However, pain reduced their ability to manage everyday life, hampered experienced possibilities for success, and made social settings difficult. Childhood experiences influence how adolescents experience pain and use over-the-counter

  4. Teacher Counter Stories to a Citizenship Education Mega Policy Narrative. Preparing for Citizenship in Chile

    ERIC Educational Resources Information Center

    Cavieres-Fernández, Eduardo

    2017-01-01

    The present article focuses on the counter stories of two Chilean social studies high school teachers. Counter stories describe how teachers use their professional experience to confront those mega narratives composed of dominant educational policies that impinge upon their pedagogical practices. The mega narrative described in this study as a…

  5. Development of Proportional Reasoning: Where Young Children Go Wrong

    PubMed Central

    Boyer, Ty W.; Levine, Susan C.; Huttenlocher, Janellen

    2008-01-01

    Previous studies have found that children have difficulty solving proportional reasoning problems involving discrete units until 10- to 12-years of age, but can solve parallel problems involving continuous quantities by 6-years of age. The present studies examine where children go wrong in processing proportions that involve discrete quantities. A computerized proportional equivalence choice task was administered to kindergartners through fourth-graders in Study 1, and to first- and third-graders in Study 2. Both studies involved four between-subjects conditions that were formed by pairing continuous and discrete target proportions with continuous and discrete choice alternatives. In Study 1, target and choice alternatives were presented simultaneously and in Study 2 target and choice alternatives were presented sequentially. In both studies, children performed significantly worse when both the target and choice alternatives were represented with discrete quantities than when either or both of the proportions involved continuous quantities. Taken together, these findings indicate that children go astray on proportional reasoning problems involving discrete units only when a numerical match is possible, suggesting that their difficulty is due to an overextension of numerical equivalence concepts to proportional equivalence problems. PMID:18793078

  6. Model of separation performance of bilinear gradients in scanning format counter-flow gradient electrofocusing techniques.

    PubMed

    Shameli, Seyed Mostafa; Glawdel, Tomasz; Ren, Carolyn L

    2015-03-01

    Counter-flow gradient electrofocusing allows the simultaneous concentration and separation of analytes by generating a gradient in the total velocity of each analyte that is the sum of its electrophoretic velocity and the bulk counter-flow velocity. In the scanning format, the bulk counter-flow velocity is varying with time so that a number of analytes with large differences in electrophoretic mobility can be sequentially focused and passed by a single detection point. Studies have shown that nonlinear (such as a bilinear) velocity gradients along the separation channel can improve both peak capacity and separation resolution simultaneously, which cannot be realized by using a single linear gradient. Developing an effective separation system based on the scanning counter-flow nonlinear gradient electrofocusing technique usually requires extensive experimental and numerical efforts, which can be reduced significantly with the help of analytical models for design optimization and guiding experimental studies. Therefore, this study focuses on developing an analytical model to evaluate the separation performance of scanning counter-flow bilinear gradient electrofocusing methods. In particular, this model allows a bilinear gradient and a scanning rate to be optimized for the desired separation performance. The results based on this model indicate that any bilinear gradient provides a higher separation resolution (up to 100%) compared to the linear case. This model is validated by numerical studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Body proportions of Homo habilis reviewed.

    PubMed

    Haeusler, Martin; McHenry, Henry M

    2004-04-01

    The ratio of fore- to hindlimb size plays an important role in our understanding of human evolution. Although Homo habilis was relatively modern craniodentally, its body proportions are commonly believed to have been more apelike than in the earlier Australopithecus afarensis. The evidence for this, however, rests, on two fragmentary skeletons, OH 62 and KNM-ER 3735. The upper limb of the better-preserved OH 62 from Olduvai Gorge is long and slender, but its hindlimb is represented mainly by the proximal portion of a thin femur of uncertain length. The present analysis shows that upper-to-lower limb shaft proportions of both OH 62 and AL 288-1 (A. afarensis) fall in the modern human range of variation, although OH 62 also falls inside that of chimpanzees due to their overlap in small individuals. Despite being more fragmentary, the larger-bodied KNM-ER 3735 lies outside the chimpanzee range and close to the human mean. Because the differences between any of the three individuals are compatible with the range of variation seen in extant hominoid groups, it is not legitimate to infer more primitive upper-to-lower limb shaft proportions for either H. habilis or A. afarensis. Femur length of OH 62 can only be estimated by comparison. Its closest match in size and morphology is with the gracile OH 34 specimen, which therefore provides a better analogue for the reconstruction of OH 62 than the stocky AL 288-1 femur that is traditionally used. OH 34's slender proportions are hardly due to abrasion, but match those of a modern human of that body-size, suggesting that the relative length of OH 62's leg may have been human-like. Brachial proportions, however, remained primitive. Long legs may imply long distance terrestrial travel. Perhaps this adaptation evolved early in the genus Homo, with H. habilis providing an early representative of this important change.

  8. Countering Children's Sugared Food Commercials: Do Rebuttals Help?

    ERIC Educational Resources Information Center

    Kaufman, Lois; Sandman, Peter M.

    To assist the Federal Trade Commission (FTC) in policy making decisions concerning sugared food advertisements on television, a study was conducted to assess the effects on children of counter advertisements and disclaimers as a means of lessening the undesirable impact of sugared food ads. Approximately 1,200 children, aged 5 to 10 years,…

  9. 3 CFR - Delegation of Certain Functions and Authorities Under the Iran Freedom and Counter-Proliferation...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 3 The President 1 2014-01-01 2014-01-01 false Delegation of Certain Functions and Authorities Under the Iran Freedom and Counter-Proliferation Act of 2012 Presidential Documents Other Presidential Documents Memorandum of June 3, 2013 Delegation of Certain Functions and Authorities Under the Iran Freedom and Counter-Proliferation Act of 2012...

  10. Counter rotating fans — An aircraft propulsion for the future?

    NASA Astrophysics Data System (ADS)

    Schimming, Peter

    2003-05-01

    In the mid seventies a new propulsor for aircraft was designed and investigated - the so-called PROPFAN. With regard to the total pressure increase, it ranges between a conventional propeller and a turbofan with very high bypass ratio. This new propulsion system promised a reduction in fuel consumption of 15 to 25% compared to engines at that time. A lot of propfans (Hamilton Standard, USA) with different numbers of blades and blade shapes have been designed and tested in wind tunnels in order to find an optimum in efficiency, Fig.1. Parallel to this development GE, USA, made a design of a counter rotating unducted propfan, the so-called UDF, Fig.2. A prototype engine was manufactured and investigated on an in-flight test bed mounted at the MD82 and the B727. Since that time there has not been any further development of propfans (except AN 70 with NK 90-engine, Ukraine, which is more or less a propeller design) due to relatively low fuel prices and technical obstacles. Only technical programs in different countries are still going on in order to prepare a data base for designing counter rotating fans in terms of aeroacoustics, aerodynamics and aeroelasticities. In DLR, Germany, a lot of experimental and numerical work has been undertaken to understand the physical behaviour of the unsteady flow in a counter rotating fan.

  11. A physiologically based nonhomogeneous Poisson counter model of visual identification.

    PubMed

    Christensen, Jeppe H; Markussen, Bo; Bundesen, Claus; Kyllingsbæk, Søren

    2018-04-30

    A physiologically based nonhomogeneous Poisson counter model of visual identification is presented. The model was developed in the framework of a Theory of Visual Attention (Bundesen, 1990; Kyllingsbæk, Markussen, & Bundesen, 2012) and meant for modeling visual identification of objects that are mutually confusable and hard to see. The model assumes that the visual system's initial sensory response consists in tentative visual categorizations, which are accumulated by leaky integration of both transient and sustained components comparable with those found in spike density patterns of early sensory neurons. The sensory response (tentative categorizations) feeds independent Poisson counters, each of which accumulates tentative object categorizations of a particular type to guide overt identification performance. We tested the model's ability to predict the effect of stimulus duration on observed distributions of responses in a nonspeeded (pure accuracy) identification task with eight response alternatives. The time courses of correct and erroneous categorizations were well accounted for when the event-rates of competing Poisson counters were allowed to vary independently over time in a way that mimicked the dynamics of receptive field selectivity as found in neurophysiological studies. Furthermore, the initial sensory response yielded theoretical hazard rate functions that closely resembled empirically estimated ones. Finally, supplied with a Naka-Rushton type contrast gain control, the model provided an explanation for Bloch's law. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Extending Counter-streaming Motion from an Active Region Filament to a Sunspot Light Bridge

    NASA Astrophysics Data System (ADS)

    Wang, Haimin; Liu, Rui; Li, Qin; Liu, Chang; Deng, Na; Xu, Yan; Jing, Ju; Wang, Yuming; Cao, Wenda

    2018-01-01

    We analyze high-resolution observations from the 1.6 m telescope at Big Bear Solar Observatory that cover an active region filament. Counter-streaming motions are clearly observed in the filament. The northern end of the counter-streaming motions extends to a light bridge, forming a spectacular circulation pattern around a sunspot, with clockwise motion in the blue wing and counterclockwise motion in the red wing, as observed in the Hα off-bands. The apparent speed of the flow is around 10–60 km s‑1 in the filament, decreasing to 5–20 km s‑1 in the light bridge. The most intriguing results are the magnetic structure and the counter-streaming motions in the light bridge. Similar to those in the filament, the magnetic fields show a dominant transverse component in the light bridge. However, the filament is located between opposed magnetic polarities, while the light bridge is between strong fields of the same polarity. We analyze the power of oscillations with the image sequences of constructed Dopplergrams, and find that the filament’s counter-streaming motion is due to physical mass motion along fibrils, while the light bridge’s counter-streaming motion is due to oscillation in the direction along the line-of-sight. The oscillation power peaks around 4 minutes. However, the section of the light bridge next to the filament also contains a component of the extension of the filament in combination with the oscillation, indicating that some strands of the filament are extended to and rooted in that part of the light bridge.

  13. Utility of Army Design Methodology in U.S. Coast Guard Counter Narcotic Interdiction Strategy

    DTIC Science & Technology

    2017-06-09

    UTILITY OF ARMY DESIGN METHODOLOGY IN U.S. COAST GUARD COUNTER NARCOTIC INTERDICTION STRATEGY A thesis presented to the...Thesis 3. DATES COVERED (From - To) AUG 2016 – JUN 2017 4. TITLE AND SUBTITLE Utility of Army Design Methodology in U.S. Coast Guard Counter...Distribution is Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT This study investigates the utility of using Army Design Methodology (ADM) to

  14. Assessment of Facial Golden Proportions among North Maharashtri-an Population

    PubMed Central

    Sunilkumar, L N; Jadhav, Kalpana S; Nazirkar, Girish; Singh, Shailendra; Nagmode, Pradnya S; Ali, Fareedi Mukram

    2013-01-01

    Background: Divine Proportion in Orthodontics and Prosthodontics has always been intriguing. This was applied to the North Maharashtrian population to evaluate the relationship between facial esthetics and the golden proportions. Materials & Methods: Facial proportions were assessed by examining photographs of sum total of 300 subjects of North Maharashtrian population. Young adults with a skeletal and dental Class 1 occlusion, competent lips, and balanced facial proportion were selected. Photographic prints were taken and manually parameters were plotted and analysis was done. Results: The measurements of anterior facial height showed proportionality with the total facial height. The values showed shorter lower anterior facial height and deviation of facial width parameters from the divine proportion indicating small mouth, nose, and narrow-set eyes with respect to the inter-temporal width. Conclusion: There is soft-tissue facial balance of North Maharashtrian population in comparison with the golden proportion. However, certain parameters show some deviation from the divine proportion.. How to cite this article: Sunilkumar L N, Jadhav K S, Nazirkar G, Singh S, Nagmode P S, Ali F M. Assessment of Facial Golden Proportions among North Maharashtrian Population. J Int Oral Health 2013; 5(3):48-54. PMID:24155602

  15. Bargaining Theory and Building Strategies for Countering Armed Groups

    DTIC Science & Technology

    2010-03-01

    actions previously labeled counter-insurgency, -terrorism, -drug, or - gang operations; irregular, unconventional, small guerilla, asymmetrical, or 4th...field of wheat, which, without regard to the individual stalk , may be mown down more or less efficiently depending on the quality of the scythe; it

  16. Slim by Design: Kitchen Counter Correlates of Obesity

    ERIC Educational Resources Information Center

    Wansink, Brian; Hanks, Andrew S.; Kaipainen, Kirsikka

    2016-01-01

    Background: The home is one place where people can control what foods are available and how the environment is arranged. Given the impact of environments on health, the objective of this study is to determine whether the presence of foods on a person's kitchen counter are associated with their body mass index (BMI). Method: In Study 1, a…

  17. Maritime Infrared Propagation: Particle Size Distribution Measurements Using a Helicopter-Borne Aerosol Counter.

    DTIC Science & Technology

    1981-09-01

    COUNTER by R. R. Allan S. Craig SUMMARY -Particle size distribution measurements were made on nine successive days in late August 1980 using a PMS FSSP-100...aerosol counter flown on a Wessex Mk 5 helicopter. In all, 14 flights were made giving data at two heights, 30 and 100 ft above the sea surface...aerosol content over deep water. It was a specific recommendation of TTCP-JAG9 that airborne aerosol measurements should be made in conjunction with al

  18. The proportionate value of proportionality in palliative sedation.

    PubMed

    Berger, Jeffrey T

    2014-01-01

    Proportionality, as it pertains to palliative sedation, is the notion that sedation should be induced at the lowest degree effective for symptom control, so that the patient's consciousness may be preserved. The pursuit of proportionality in palliative sedation is a widely accepted imperative advocated in position statements and guidelines on this treatment. The priority assigned to the pursuit of proportionality, and the extent to which it is relevant for patients who qualify for palliative sedation, have been overstated. Copyright 2014 The Journal of Clinical Ethics. All rights reserved.

  19. Taxing Junk Food to Counter Obesity

    PubMed Central

    Franck, Caroline; Grandi, Sonia M.

    2013-01-01

    We examined the advantages and disadvantages of implementing a junk food tax as an intervention to counter increasing obesity in North America. Small excise taxes are likely to yield substantial revenue but are unlikely to affect obesity rates. High excise taxes are likely to have a direct impact on weight in at-risk populations but are less likely to be politically palatable or sustainable. Ultimately, the effectiveness of earmarked health programs and subsidies is likely to be a key determinant of tax success in the fight against obesity. PMID:24028245

  20. Taxing junk food to counter obesity.

    PubMed

    Franck, Caroline; Grandi, Sonia M; Eisenberg, Mark J

    2013-11-01

    We examined the advantages and disadvantages of implementing a junk food tax as an intervention to counter increasing obesity in North America. Small excise taxes are likely to yield substantial revenue but are unlikely to affect obesity rates. High excise taxes are likely to have a direct impact on weight in at-risk populations but are less likely to be politically palatable or sustainable. Ultimately, the effectiveness of earmarked health programs and subsidies is likely to be a key determinant of tax success in the fight against obesity.

  1. A Simulation of Counter-Cyclical Intervention: Some Practical Lessons

    ERIC Educational Resources Information Center

    Grawe, Nathan D.; Watts, Michael, Ed.

    2007-01-01

    The author introduces a simulation of counter-cyclical interventions that highlights important issues surrounding the practice of government intervention. The simulation provides experiential insight as to why economists have long debated the degree of persistence exhibited by disequilibrating shocks and connects this debate to discussions about…

  2. Development of a model counter-rotating type horizontal-axis tidal turbine

    NASA Astrophysics Data System (ADS)

    Huang, B.; Yoshida, K.; Kanemoto, T.

    2016-05-01

    In the past decade, the tidal energies have caused worldwide concern as it can provide regular and predictable renewable energy resource for power generation. The majority of technologies for exploiting the tidal stream energy are based on the concept of the horizontal axis tidal turbine (HATT). A unique counter-rotating type HATT was proposed in the present work. The original blade profiles were designed according to the developed blade element momentum theory (BEMT). CFD simulations and experimental tests were adopted to the performance of the model counter-rotating type HATT. The experimental data provides an evidence of validation of the CFD model. Further optimization of the blade profiles was also carried out based on the CFD results.

  3. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Renaud, G.; Bosch, J. G.; ten Kate, G. L.; Shamdasani, V.; Entrekin, R.; de Jong, N.; van der Steen, A. F. W.

    2012-11-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.

  4. Citropin 1.1 Trifluoroacetate to Chloride Counter-Ion Exchange in HCl-Saturated Organic Solutions: An Alternative Approach.

    PubMed

    Sikora, Karol; Neubauer, Damian; Jaśkiewicz, Maciej; Kamysz, Wojciech

    2018-01-01

    In view of the increasing interest in peptides in various market sectors, a stronger emphasis on topics related to their production has been seen. Fmoc-based solid phase peptide synthesis, although being fast and efficient, provides final products with significant amounts of trifluoroacetate ions in the form of either a counter-ion or an unbound impurity. Because of the proven toxicity towards cells and peptide activity inhibition, ion exchange to more biocompatible one is purposeful. Additionally, as most of the currently used counter-ion exchange techniques are time-consuming and burdened by peptide yield reduction risk, development of a new approach is still a sensible solution. In this study, we examined the potential of peptide counter-ion exchange using non-aqueous organic solvents saturated with HCl. Counter-ion exchange of a model peptide, citropin 1.1 (GLFDVIKKVASVIGGL-NH 2 ), for each solvent was conducted through incubation with subsequent evaporation under reduced pressure, dissolution in water and lyophilization. Each exchange was performed four times and compared to a reference method-lyophilization of the peptide from an 0.1 M HCl solution. The results showed superior counter-ion exchange efficiency for most of the organic solutions in relation to the reference method. Moreover, HCl-saturated acetonitrile and tert -butanol provided a satisfying exchange level after just one repetition. Thus, those two organic solvents can be potentially introduced into routine peptide counter-ion exchange.

  5. Inverse opal carbons for counter electrode of dye-sensitized solar cells.

    PubMed

    Kang, Da-Young; Lee, Youngshin; Cho, Chang-Yeol; Moon, Jun Hyuk

    2012-05-01

    We investigated the fabrication of inverse opal carbon counter electrodes using a colloidal templating method for DSSCs. Specifically, bare inverse opal carbon, mesopore-incoporated inverse opal carbon, and graphitized inverse opal carbon were synthesized and stably dispersed in ethanol solution for spray coating on a FTO substrate. The thickness of the electrode was controlled by the number of coatings, and the average relative thickness was evaluated by measuring the transmittance spectrum. The effect of the counter electrode thickness on the photovoltaic performance of the DSSCs was investigated and analyzed by interfacial charge transfer resistance (R(CT)) under EIS measurement. The effect of the surface area and conductivity of the inverse opal was also investigated by considering the increase in surface area due to the mesopore in the inverse opal carbon and conductivity by graphitization of the carbon matrix. The results showed that the FF and thereby the efficiency of DSSCs were increased as the electrode thickness increased. Consequently, the larger FF and thereby the greater efficiency of the DSSCs were achieved for mIOC and gIOC compared to IOC, which was attributed to the lower R(CT). Finally, compared to a conventional Pt counter electrode, the inverse opal-based carbon showed a comparable efficiency upon application to DSSCs.

  6. Remedy or cure? Lay beliefs about over-the-counter medicines for coughs and colds.

    PubMed Central

    Johnson, Gina; Helman, Cecil

    2004-01-01

    BACKGROUND: Over 500 million is spent in the United Kingdom every year on over-the-counter medicines for coughs and colds. Evidence for their pharmacological efficacy is lacking. AIM: To examine lay beliefs about over-the-counter medicines for coughs and colds. To explore whether the distinction between symptom relief and cure has the same relevance to lay people as it does to medical professionals. DESIGN OF STUDY: Small pilot study using qualitative techniques. SETTING: Variety sample of 11 patients attending the National Health Service walk-in centre, Birmingham, England. METHOD: In-depth semi-structured interviews, including pile-sorting and fictional case histories, were used to explore participants' beliefs about the effects of over-the-counter medicines on coughs and colds. RESULTS: Eight of the 11 participants believed that at least one over the-counter cough medicine (most frequently Benylin for Chesty Coughs) could shorten, or "cure", an illness. Five participants thought that the majority of the medicines that they recognised would speed recovery rather than just relieve symptoms. CONCLUSIONS: There is a common confusion in the lay person's mind between the ability of a medicine to relieve symptoms, and its ability to cure a disease or to hasten recovery. This misunderstanding may affect the demand for primary care consultations. PMID:14965387

  7. Putative golden proportions as predictors of facial esthetics in adolescents.

    PubMed

    Kiekens, Rosemie M A; Kuijpers-Jagtman, Anne Marie; van 't Hof, Martin A; van 't Hof, Bep E; Maltha, Jaap C

    2008-10-01

    In orthodontics, facial esthetics is assumed to be related to golden proportions apparent in the ideal human face. The aim of the study was to analyze the putative relationship between facial esthetics and golden proportions in white adolescents. Seventy-six adult laypeople evaluated sets of photographs of 64 adolescents on a visual analog scale (VAS) from 0 to 100. The facial esthetic value of each subject was calculated as a mean VAS score. Three observers recorded the position of 13 facial landmarks included in 19 putative golden proportions, based on the golden proportions as defined by Ricketts. The proportions and each proportion's deviation from the golden target (1.618) were calculated. This deviation was then related to the VAS scores. Only 4 of the 19 proportions had a significant negative correlation with the VAS scores, indicating that beautiful faces showed less deviation from the golden standard than less beautiful faces. Together, these variables explained only 16% of the variance. Few golden proportions have a significant relationship with facial esthetics in adolescents. The explained variance of these variables is too small to be of clinical importance.

  8. Normative and counter-normative stress messages and symptom reporting: implications for health promotion and a methodological artefact for stress research.

    PubMed

    Ferguson, Eamonn; Lawrence, Claire

    2013-05-01

    There is increasing use of counter-normative health messages (i.e., evidence-based health information about cause-effect relationships that run counter to shared normative beliefs, e.g., stress can lead to personal growth). The current studies examine the effect of normative and counter-normative messages about stress on levels of symptom reporting. Predictions are derived from reactance, social comparison, and self-enhancement theories. Two studies focus on the development of the messages, and two experimental studies examine the effect of manipulating normative and counter-normative messages on symptom reports. The final study controls for mere-measurement effects and explores the role of stress process variables (appraisals and coping). Exposure to a normative message (stress causes ill health) results in reduced symptom reporting compared to a counter-normative message (stress provides challenge, growth, and development) and control groups. The results suggest that people may use symptom reporting strategically to indicate coping. Based on the argument that beliefs about stress and health are stored as mental models, the theoretical associations derived from stress theory are only observed when a normative message is presented. Counter-normative stress messages may carry no tangible benefits compared to normative messages. Some stress research may suffer from inherent methodological bias when normative information is provided in information and consent sheets. Statement of contribution What is already known on this subject? At present, nothing is known about counter-normative health messages, despite the fact that they are becoming widely used as a public intervention. What does this study add? A clear operational definition of counter-normative messages. A test of three competing theories for counter-normative messages that focus of the stress-symptom link. Demonstrating for the first time, that in the domain of stress and health, counter-normative messages

  9. First birth cesarean proportion: A missed indicator in controlling policies

    PubMed Central

    Safari-Faramani, Roya; Haghdoost, Ali Akbar; Nakhaei, Nouzar; Foroudnia, Shohreh; Mahmoodabadi, Zahra; Safizadeh, Mansooreh

    2016-01-01

    Background: Around one out of two mothers give births by cesarean section (CS) surgery in Iran and about half of this number is due to previous CS. Recently Health Sector Evolution (HSEP) program (started in April 2014) targets the high rate of CS in Iran. To assess the impact of the interventions, we emphasized that the First Birth Cesarean (FBC) proportion is one of the main indicators to assess the controlling programs. Methods: Data on the mode of delivery were collected in Kerman province between 21 March and 20 March 2015 classified by hospital ownership. FBC proportion is defined as the number of CS in the first pregnancies divided by the total number of first births. Chi-square test for trend was used to assess the trends. Results: Total number of births was around 34000. There were 8.9 and 13.1 percent reduction in CS and FBC proportion respectively. CS proportion was 54.5 at the end of the first quarter of the studied period and reached to 49.6 at the end of the period (p<0.0001). Also, FBC proportion was 54.1 percent at first and reached to 47 percent at the end of the study period. The main reason for CS was due to previous CS. At the hospital level, the highest reduction in CS and FBC proportion were in public hospitals. Conclusion: Results suggested more reduction in FBC proportion than the CS proportion, so this is a very good sign since more potential CS cases will be prevented. As repeated CS is one of the main indications for the operation, in the short term, even effective policies may change the overall proportion slightly, while the FBC proportion is more sensitive to reflect the impacts. Therefore, it is necessary to target the main fuel to reduce CS proportion effectively. PMID:27579285

  10. Counter-narcotic acoustic buoy (CNAB)

    NASA Astrophysics Data System (ADS)

    Bailey, Mark E.

    2004-09-01

    As a means to detect drug trafficking in a maritime environment, the Counter Narcotic Acoustic Buoy is part of an inexpensive system designed to detect "Go Fast" boats and report via satellite to a designated location. A go fast boat for this evaluation is defined as any boat with twin 200 horsepower outboard engines. The buoy is designed for deployment in salt water at depths ranging from 50 to 600 feet and can be easily deployed by one or two persons. Detections are based on noise energy exceeding a preset level within a frequency band associated with the go fast boat's acoustic signature. Detection ranges have been demonstrated to greater than three nautical miles.

  11. Scintillator Non-Proportionality: Present Understanding and Future Challenges

    NASA Astrophysics Data System (ADS)

    Moses, W. W.; Payne, S. A.; Choong, W.-S.; Hull, G.; Reutter, B. W.

    2008-06-01

    Scintillator non-proportionality (the fact that the conversion factor between the energy deposited in a scintillator and the number of visible photons produced is not constant) has been studied both experimentally and theoretically for 50 years. Early research centered on the dependence of the conversion factor on the species of the ionizing radiation (gamma, alpha, beta, proton, etc.), and researchers during the 1960s discovered a strong correlation between the scintillation efficiency and the ionization density. In more recent years, non-proportionality has been proposed as the reason why the energy resolution of most scintillators is worse than that predicted by counting statistics. While much progress has been made, there are still major gaps in our understanding of both the fundamental causes of non-proportionality and their quantitative link to scintillator energy resolution. This paper summarizes the present state of knowledge on the nature of the light-yield non-proportionality and its effect on energy resolution.

  12. Ocular Counter-Rolling During Centrifugation and Static Tilt

    NASA Technical Reports Server (NTRS)

    Cohen, Bernard; Clement, Gilles; Moore, Steven; Curthoys, Ian; Dai, Mingjia; Koizuka, Izumi; Kubo, Takeshi; Raphan, Theodore

    2003-01-01

    Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1

  13. 16. INTERIOR OF KITCHEN SHOWING UPDATED CABINETS AND COUNTER TOP, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. INTERIOR OF KITCHEN SHOWING UPDATED CABINETS AND COUNTER TOP, AND ORIGINAL WOOD-FRAMED SLIDING GLASS WINDOW IN NORTH WALL OVERLOOKING FRONT ENTRY. VIEW TO NORTHEAST. - Rush Creek Hydroelectric System, Worker Cottage, Rush Creek, June Lake, Mono County, CA

  14. Fabrication and study of cylindrical scintillation counters of the ARES spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baranov, V.A.; Evtukhovich, P.G.; Korenchenko, S.M.

    A method is described for fabricating 600 x 87 x 5 mm plastic scintillation counters which are constituent elements of a 673 mm in diameter cylindrical hodoscope. Results of investigations into the amplitude and temporal characteristics of a separate scintillation are presented. Light losses in the transitional and main lightguides were determined primarily by the absorption length of the organic glass. The time resolution of the counter with the beta source placed at the center of the scintillator equaled 1 nsec; the velocity of propagation of light in the scintillator equals 12.1 cm/nsec. The ARES spectrometer detects electrons and gammamore » rays under conditions of high meson-stopping intensity and will be used for pion and muon rare decay studies.« less

  15. A New Concept for Counter-Checking of Assumed CPM Pairs

    NASA Astrophysics Data System (ADS)

    Knapp, Wilfried; Nanson, John

    2017-01-01

    The inflation of “newly discovered” CPM pairs makes it necessary to develop an approach for a solid concept for counter-checking assumed CPM pairs with the target to identify false positives. Such a concept is presented in this report.

  16. Counter-facing plasma guns for efficient extreme ultra-violet plasma light source

    NASA Astrophysics Data System (ADS)

    Kuroda, Yusuke; Yamamoto, Akiko; Kuwabara, Hajime; Nakajima, Mitsuo; Kawamura, Tohru; Horioka, Kazuhiko

    2013-11-01

    A plasma focus system composed of a pair of counter-facing coaxial guns was proposed as a long-pulse and/or repetitive high energy density plasma source. We applied Li as the source of plasma for improvement of the conversion efficiency, the spectral purity, and the repetition capability. For operation of the system with ideal counter-facing plasma focus mode, we changed the system from simple coaxial geometry to a multi-channel configuration. We applied a laser trigger to make synchronous multi-channel discharges with low jitter. The results indicated that the configuration is promising to make a high energy density plasma with high spectral efficiency.

  17. The principle of proportionality revisited: interpretations and applications.

    PubMed

    Hermerén, Göran

    2012-11-01

    The principle of proportionality is used in many different contexts. Some of these uses and contexts are first briefly indicated. This paper focusses on the use of this principle as a moral principle. I argue that under certain conditions the principle of proportionality is helpful as a guide in decision-making. But it needs to be clarified and to be used with some flexibility as a context-dependent principle. Several interpretations of the principle are distinguished, using three conditions as a starting point: importance of objective, relevance of means, and most favourable option. The principle is then tested against an example, which suggests that a fourth condition, focusing on non-excessiveness, needs to be added. I will distinguish between three main interpretations of the principle, some primarily with uses in research ethics, others with uses in other areas of bioethics, for instance in comparisons of therapeutic means and ends. The relations between the principle of proportionality and the precautionary principle are explored in the following section. It is concluded that the principles are different and may even clash. In the next section the principle of proportionality is applied to some medical examples drawn from research ethics and bioethics. In concluding, the status of the principle of proportionality as a moral principle is discussed. What has been achieved so far and what remains to be done is finally summarized.

  18. Effects of counter-rotating-wave terms of the driving field on the spectrum of resonance fluorescence

    NASA Astrophysics Data System (ADS)

    Yan, Yiying; Lü, Zhiguo; Zheng, Hang

    2013-11-01

    We investigate the fluorescence spectrum of a two-level system driven by a monochromatic classical field by the Born-Markovian master equation based on a unitary transformation. The main purpose is to understand the effects of counter-rotating-wave terms of the driving on spectral features of the fluorescence. We have derived an analytical expression for the fluorescence spectrum, which is different from Mollow's theory, while Mollow's result on resonance is the limiting case of ours in moderately weak driving regimes. Our results demonstrate precisely that the counter-rotating-wave terms of the driving play an important role in the fluorescence spectrum for intense driving: (i) the counter-rotating coupling suppresses the red sideband in the Mollow triplet and it enhances the blue one in explicitly contrast to the well-known equal intensity of the sideband in Mollow's theory, (ii) the higher-order Mollow triplets appear as a characteristic spectral feature arising from counter-rotating-wave terms of the driving, and (iii) a significant frequency shift of the sidebands is observed, which depends on both the detuning and driving strength.

  19. Parts Counter. Pre-Apprenticeship Phase 2 Training. Instructor's Guide.

    ERIC Educational Resources Information Center

    Snyder, James A.

    This instructor's guide accompanies the self-paced student training modules on parts counter, available separately as CE 031 572. Introductory materials include a description of the components of the pre-apprenticeship project, discussion of teacher's role in students' completion of the modules, and scope and contents of Phase 2 training. Each of…

  20. Assessment of facial golden proportions among central Indian population.

    PubMed

    Saurabh, Rathore; Piyush, Bolya; Sourabh, Bhatt; Preeti, Ojha; Trivedi, Rutvik; Vishnoi, Pradeep

    2016-12-01

    This study aimed to identify and establish the facial and smile proportions in young adults and to compare the results with ideal or divine proportions, compare the proportions of males and females included in our study population and compare them with those established for Caucasian and Japanese populations. Two hundred participants (164 females, 36 males) with Angle's class I malocclusion (M.O). and well-balanced faces were selected and photographed in the frontal repose position. Analysis was done in Adobe Photoshop software. Statistical analysis was done using the Statistical Package for the Social Sciences version 17.0. (IBM Corporation Armonk, New York, United States). Results suggested that females are more near to ideal ratios and males are more deviated from the ideal ratios. The proportions of males and females were not considerably different from each other. In Indian population, upper 3 rd facial height (TR-LC) was increased and mid-face height (LC-LN) was decreased; in lower 3 rd of the face, LN-CH was slightly increased in comparison to CH-ME. In facial widths, outer canthal width (LC-LC) was greater in the Indian population and mouth width (CH-CH) was normal. When compared with Indian population, Japanese participants had wider noses, outer canthal distance, and bitemporal width. It was concluded that significant difference was found between the proportions of the Indian population and ideal ratio. When Indian population was compared with Japanese and Caucasian populations, some parameters of facial proportions showed significant difference, which leads to the need for establishing standardized norms for various facial proportions in Indian population.

  1. Electrochemically Reduced Graphene Oxide Multilayer Films as Efficient Counter Electrode for Dye-Sensitized Solar Cells

    PubMed Central

    Xu, Xiaobao; Huang, Dekang; Cao, Kun; Wang, Mingkui; Zakeeruddin, Shaik M.; Grätzel, Michael

    2013-01-01

    We report on a new counter electrode for dye-sensitized solar cells (DSCs), which is prepared using layer-by-layer assembly of negatively charged graphene oxide and positively charged poly (diallyldimethylammonium chloride) followed by an electrochemical reduction procedure. The DSC devises using the heteroleptic Ru complex C106TBA as sensitizer and this new counter electrode reach power conversion efficiencies of 9.5% and 7.6% in conjunction with low volatility and solvent free ionic liquid electrolytes, respectively. The new counter electrode exhibits good durability (60°C for 1000 h in a solar simulator, 100 mW cm−2) during the accelerated tests when used in combination with an ionic liquid electrolyte. This work identifies a new class of electro-catalysts with potential for low cost photovoltaic devices. PMID:23508212

  2. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  3. Divergent discourse between protests and counter-protests: #BlackLivesMatter and #AllLivesMatter.

    PubMed

    Gallagher, Ryan J; Reagan, Andrew J; Danforth, Christopher M; Dodds, Peter Sheridan

    2018-01-01

    Since the shooting of Black teenager Michael Brown by White police officer Darren Wilson in Ferguson, Missouri, the protest hashtag #BlackLivesMatter has amplified critiques of extrajudicial killings of Black Americans. In response to #BlackLivesMatter, other Twitter users have adopted #AllLivesMatter, a counter-protest hashtag whose content argues that equal attention should be given to all lives regardless of race. Through a multi-level analysis of over 860,000 tweets, we study how these protests and counter-protests diverge by quantifying aspects of their discourse. We find that #AllLivesMatter facilitates opposition between #BlackLivesMatter and hashtags such as #PoliceLivesMatter and #BlueLivesMatter in such a way that historically echoes the tension between Black protesters and law enforcement. In addition, we show that a significant portion of #AllLivesMatter use stems from hijacking by #BlackLivesMatter advocates. Beyond simply injecting #AllLivesMatter with #BlackLivesMatter content, these hijackers use the hashtag to directly confront the counter-protest notion of "All lives matter." Our findings suggest that Black Lives Matter movement was able to grow, exhibit diverse conversations, and avoid derailment on social media by making discussion of counter-protest opinions a central topic of #AllLivesMatter, rather than the movement itself.

  4. Divergent discourse between protests and counter-protests: #BlackLivesMatter and #AllLivesMatter

    PubMed Central

    Reagan, Andrew J.; Danforth, Christopher M.; Dodds, Peter Sheridan

    2018-01-01

    Since the shooting of Black teenager Michael Brown by White police officer Darren Wilson in Ferguson, Missouri, the protest hashtag #BlackLivesMatter has amplified critiques of extrajudicial killings of Black Americans. In response to #BlackLivesMatter, other Twitter users have adopted #AllLivesMatter, a counter-protest hashtag whose content argues that equal attention should be given to all lives regardless of race. Through a multi-level analysis of over 860,000 tweets, we study how these protests and counter-protests diverge by quantifying aspects of their discourse. We find that #AllLivesMatter facilitates opposition between #BlackLivesMatter and hashtags such as #PoliceLivesMatter and #BlueLivesMatter in such a way that historically echoes the tension between Black protesters and law enforcement. In addition, we show that a significant portion of #AllLivesMatter use stems from hijacking by #BlackLivesMatter advocates. Beyond simply injecting #AllLivesMatter with #BlackLivesMatter content, these hijackers use the hashtag to directly confront the counter-protest notion of “All lives matter.” Our findings suggest that Black Lives Matter movement was able to grow, exhibit diverse conversations, and avoid derailment on social media by making discussion of counter-protest opinions a central topic of #AllLivesMatter, rather than the movement itself. PMID:29668754

  5. Counter-advertising may reduce parent's susceptibility to front-of-package promotions on unhealthy foods.

    PubMed

    Dixon, Helen; Scully, Maree; Kelly, Bridget; Donovan, Robert; Chapman, Kathy; Wakefield, Melanie

    2014-01-01

    Assess the effect of counter-advertisements on parents' appraisals of unhealthy foods featuring front-of-package promotions (FOPPs). A 2 × 2 × 5 between-subjects Web-based experiment. Parents were randomly shown an advertisement (counter-advertisement challenging FOPP/control advertisement) and then a pair of food products from the same category: an unhealthy product featuring an FOPP (nutrient content claim/sports celebrity endorsement) and a healthier control product with no FOPP. Australia. A total of 1,269 Australian-based parents of children aged 5-12 years recruited from an online panel. Parents nominated which product they would prefer to buy and which they thought was healthier, then rated the unhealthy product and FOPP on various characteristics. Differences between advertisement conditions were assessed using logistic regression (product choice tasks) and analysis of variance tests (ratings of unhealthy product and FOPP). Compared with parents who saw a control advertisement, parents who saw a counter-advertisement perceived unhealthy products featuring FOPPs as less healthy, expressed weaker intentions for buying such products, and were more likely to read the nutrition facts panel before nominating choices (all P < .001). Counter-advertising may help reduce the misleading influence of unhealthy food marketing and improve the accuracy of parents' evaluations of how nutritious promoted food products are. Copyright © 2014 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  6. High-level neutron coincidence counter maintenance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  7. Making Space for Spatial Proportions

    ERIC Educational Resources Information Center

    Matthews, Percival G.; Hubbard, Edward M.

    2017-01-01

    The three target articles presented in this special issue converged on an emerging theme: the importance of spatial proportional reasoning. They suggest that the ability to map between symbolic fractions (like 1/5) and nonsymbolic, spatial representations of their sizes or "magnitudes" may be especially important for building robust…

  8. The 3 DLE instrument on ATS-5. [plasma electron counter

    NASA Technical Reports Server (NTRS)

    Deforest, S. E.

    1973-01-01

    The performance and operation of the DLE plasma electron counter on board the ATS 5 are described. Two methods of data presentation, microfilm line plots and spectrograms, are discussed along with plasma dynamics, plasma flow velocity, electrostatic charging, and wave-particle interactions.

  9. Studies of nonlinear interactions between counter-propagating Alfv'en waves in the LAPD

    NASA Astrophysics Data System (ADS)

    Auerbach, D. W.; Perez, J. C.; Carter, T. A.; Boldyrev, S.

    2007-11-01

    From a weak turbulence point of view, nonlinear interactions between shear Alfv'en waves are fundamental to the energy cascade in low-frequency magnetic turbulence. We report here on an experimental study of counter-propagating Alfv'en wave interactions in the Large Plasma Device (LAPD) at UCLA. Colliding, orthogonally polarized kinetic Alfv'en waves are generated by two antennae, separated by 5m along the guide magnetic field. Magnetic field and langmuir probes record plasma behavior between the antennae. When each antenna is operated separately, linearly polarized Alfv'en waves propagate in opposite directions along the guide field. When two antennae simultaneously excite counter propagating waves, we observe multiple side bands in the frequency domain, whose amplitude scales quadratically with wave amplitude. In the spatial domain we observe non-linear superposition in the 2D structure of the waves and spectral broadening in the perpendicular wave-number spectrum. This indicates the presence of nonlinear interaction of the counter propagating Alfv'en waves, and opens the possiblity to investigate Alfv'enic plasma turbulence in controlled and reproducible laboratory experiments.

  10. Student Obstacles in Ratio and Proportion Learning

    NASA Astrophysics Data System (ADS)

    Andini, W.; Jupri, Al

    2017-02-01

    Ratio and proportion are mathematics topics that are learned in elementary school. In the learning process, teachers often found students who have difficulties in learning these topics. Analysing the difficulties on the topics is important for teachers, as an attempt to doa reflection of the learning process and as a reference in devising a learning plan, including for anticipation of the possibility of these barriers that might appear in the next learning process. This research used as the qualitative method, and involved 49 students of grade 5 and one teacher. From the analysis of the data, i.e., student test results and observation of the learning, we found some obstacles that faced by students, such as students confused in understanding about ratio and proportion topic, students found it difficult in completing the problem which have different contexts, the learning material of ratio and proportion topic that presented in textbooks are still partial (not depth), and the lack of ability of the teacher in creating problems.

  11. Counter-ion binding and mobility in the presence of hydrophobic polyions – combining molecular dynamics simulations and NMR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Druchok, Maksym; Malikova, Natalie; Rollet, Anne-Laure

    Counter-ion binding and mobility in aqueous solutions of partially hydrophobic ionene oligoions is studied here by a combination of all-atomic molecular dynamics (MD) simulations and NMR ({sup 19}F and {sup 81}Br nuclei) measurements. We present results for 12, 12–ionenes in the presence of different halide ions (F{sup −}, Cl{sup −}, Br{sup −} and I{sup −}), as well as their mixtures; the latter allowing us to probe counter-ion selectivity of these oligoions. We consolidate both structural and dynamic information, in particular simulated radial distribution functions and average residence times of counter-ions in the vicinity of ionenes and NMR data in themore » form of counter-ion chemical shift and self-diffusion coefficients. On one hand, previously reported enthalpy of dilution and mixing measurements show a reverse counter-ion sequence for 12, 12–ionenes with respect to their less hydrophobic 3, 3– and 6, 6– analogues. On the other hand, the current MD and NMR data, reflecting the counter-ion binding tendencies to the ionene chain, give evidence for the same ordering as that observed by MD for 3, 3–ionenes. This is not seen as a contradiction and can be rationalized on the basis of increasing chain hydrophobicity, which has different consequences for enthalpy and ion-binding. The latter is reflecting free energy changes and as such includes both enthalpic and entropic contributions.« less

  12. The role of social networks and media receptivity in predicting age of smoking initiation: a proportional hazards model of risk and protective factors.

    PubMed

    Unger, J B; Chen, X

    1999-01-01

    The increasing prevalence of adolescent smoking demonstrates the need to identify factors associated with early smoking initiation. Previous studies have shown that smoking by social network members and receptivity to pro-tobacco marketing are associated with smoking among adolescents. It is not clear, however, whether these variables also are associated with the age of smoking initiation. Using data from 10,030 California adolescents, this study identified significant correlates of age of smoking initiation using bivariate methods and a multivariate proportional hazards model. Age of smoking initiation was earlier among those adolescents whose friends, siblings, or parents were smokers, and among those adolescents who had a favorite tobacco advertisement, had received tobacco promotional items, or would be willing to use tobacco promotional items. Results suggest that the smoking behavior of social network members and pro-tobacco media influences are important determinants of age of smoking initiation. Because early smoking initiation is associated with higher levels of addiction in adulthood, tobacco control programs should attempt to counter these influences.

  13. Parts Counter. Pre-Apprenticeship Phase 1 Training. Instructor's Guide.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This instructor's guide is designed to accompany self-paced student training modules on the Parts Counter Trade. Introductory materials include an introduction to pre-apprenticeship training, and a course outline. Teaching outlines are then provided for the 11 modules that comprise this course. For each module some or all of this material may be…

  14. Swot analysis of using aerostats for surveillance in counter terrorism

    NASA Astrophysics Data System (ADS)

    Çetin, Hüseyin

    2013-06-01

    In today's conjuncture, the terrorist activities are the most compelling issue for the defence forces in maintaining homeland security. Especially, the terrorist elements that penetrate the homeland may give harm. This harm can be minimized by preventing the terrorist penetrations from homeland borders. In counter terrorism, having Intelligence, Surveillance and Reconnaissance (ISR) capability and using this capability by twenty four hours is deterrence for the terrorist groups. Aerostats emerge as the ideal platform which can provide this capability. Aerostats are unmanned and aerodynamically shaped balloons that are stayed in the air, fixed to the ground by steel cable(s). The aerostat is made of a large fabric envelope that is filled with nonflammable helium gas, which provides the lifting force. The cables also serve to supply the electrical power to the aerostat systems, and for data relay between the aerostat and the ground station. Aerostats are different from the other manned and Unmanned Aerial Vehicles (UAVs) because of aerostats' capabilities such as cost effectiveness, long endurance and high resolution image transmission. Especially having uninterrupted image transmission and surveillance capabilities is important to be advantageous in counter terrorism. In this article, a short definition of terrorism has been given and then the importance of ensuring the homeland border security has been emphasized in counter terrorism. In addition, the questions of "what are the technical capabilities, the usage areas and the purposes of aerostats?" will be introduced as a result of literature review. Finally the strengths and weaknesses of aerostats, opportunities and threats for the near future will be introduced by using "SWOT" analysis method.

  15. Masked Proportional Routing

    NASA Technical Reports Server (NTRS)

    Wolpert, David H. (Inventor)

    2003-01-01

    Distributed approach for determining a path connecting adjacent network nodes, for probabilistically or deterministically transporting an entity, with entity characteristic mu from a source node to a destination node. Each node i is directly connected to an arbitrary number J(mu) of nodes, labeled or numbered j=jl, j2, .... jJ(mu). In a deterministic version, a J(mu)-component baseline proportion vector p(i;mu) is associated with node i. A J(mu)-component applied proportion vector p*(i;mu) is determined from p(i;mu) to preclude an entity visiting a node more than once. Third and fourth J(mu)-component vectors, with components iteratively determined by Target(i;n(mu);mu),=alpha(mu).Target(i;n(mu)-1;mu)j+beta(mu).p* (i;mu)j and Actual(i;n(mu);+a(mu)j. Actual(i;n(mu)-l;mu)j+beta(mu).Sent(i;j'(mu);n(mu)-1;mu)j, are computed, where n(mu) is an entity sequence index and alpha(mu) and beta(mu) are selected numbers. In one embodiment, at each node i, the node j=j'(mu) with the largest vector component difference, Target(i;n(mu);mu)j'- Actual (i;n(mu);mu)j'. is chosen for the next link for entity transport, except in special gap circumstances, where the same link is optionally used for transporting consecutively arriving entities. The network nodes may be computer-controlled routers that switch collections of packets, frames, cells or other information units. Alternatively, the nodes may be waypoints for movement of physical items in a network or for transformation of a physical item. The nodes may be states of an entity undergoing state transitions, where allowed transitions are specified by the network and/or the destination node.

  16. A comparison of muscle activity in concentric and counter movement maximum bench press.

    PubMed

    van den Tillaar, Roland; Ettema, Gertjan

    2013-01-01

    The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position.

  17. A Comparison of Muscle Activity in Concentric and Counter Movement Maximum Bench Press

    PubMed Central

    van den Tillaar, Roland; Ettema, Gertjan

    2013-01-01

    The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position. PMID:24235985

  18. Spatial Proportional Reasoning Is Associated with Formal Knowledge about Fractions

    ERIC Educational Resources Information Center

    Möhring, Wenke; Newcombe, Nora S.; Levine, Susan C.; Frick, Andrea

    2016-01-01

    Proportional reasoning involves thinking about parts and wholes (i.e., about fractional quantities). Yet, research on proportional reasoning and fraction learning has proceeded separately. This study assessed proportional reasoning and formal fraction knowledge in 8- to 10-year-olds. Participants (N = 52) saw combinations of cherry juice and water…

  19. Measuring the radioactivity of drinking water with the liquid counters M2H in combination with contamination meters IM 4457

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanhemmen, J.J.; Vanhoek, L.P.; Aten, J.B.T.

    1976-01-01

    The relationship between the meter indications and the radioactivity of fission products in drinking water for the combination contamination meter IM 4457 and liquid counter M2H was investigated. The experimental setup is presented, the efficiency of the liquid counter for a mixture of fission products is briefly dealt with, and the use of the combination counter/meter in the field is discussed.

  20. Proportion estimation using prior cluster purities

    NASA Technical Reports Server (NTRS)

    Terrell, G. R. (Principal Investigator)

    1980-01-01

    The prior distribution of CLASSY component purities is studied, and this information incorporated into maximum likelihood crop proportion estimators. The method is tested on Transition Year spring small grain segments.

  1. 19. INTERIOR OF KITCHEN SHOWING UPDATED CABINETS, COUNTER TOP, SINK, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. INTERIOR OF KITCHEN SHOWING UPDATED CABINETS, COUNTER TOP, SINK, AND FAUCET, AND ORIGINAL WOODFRAMED SLIDING GLASS WINDOW IN NORTH WALL AT PHOTO LEFT CENTER OVERLOOKING FRONT PORCH. VIEW TO NORTHEAST. - Rush Creek Hydroelectric System, Worker Cottage, Rush Creek, June Lake, Mono County, CA

  2. Counter-current carbon dioxide purification of partially deacylated sunflower oil

    USDA-ARS?s Scientific Manuscript database

    High oleic sunflower oil was partially deacylated by propanolysis to produce a mixture of diglycerides and triglycerides. To remove by-product fatty acid propyl esters (FAPEs) from this reaction mixture, a liquid carbon dioxide (L-CO2) counter-current fractionation method was developed. The fracti...

  3. Dynamic Asset Allocation Approaches for Counter-Piracy Operations

    DTIC Science & Technology

    2012-07-01

    problem, has attracted much interest due to an increase in the number of pirate activities in recent years. Marsh [26] provided a game theoretic...model, where one interdiction asset and one surveillance asset are utilized for a counter-piracy mission. Due to the two-person zero sum game structure...that policy using online learning and simulation. The attractive aspects of rollout algorithms are its simplicity, broad applicability, and

  4. Counter-Insurgency Lessons from the French-Algerian War

    DTIC Science & Technology

    2004-02-09

    the behavior of foreign governments, organizations, groups, and individuals.”20 PSYOP capability currently exists only in specialized units, organized...as necessary to counter the threat. As described by communist doctrine, terrorists can be compared to “ fish swimming in the ocean of the people.”26...greater threat than the military, and that the military is capable and willing to protect them, they will come forward and deliver intelligence. The

  5. Cloud condensation nucleus counter by impactor sampling technique

    NASA Technical Reports Server (NTRS)

    Ohtake, T.

    1981-01-01

    Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.

  6. Analog quadrature signal to phase angle data conversion by a quadrature digitizer and quadrature counter

    DOEpatents

    Buchenauer, C.J.

    1981-09-23

    The quadrature phase angle phi (t) of a pair of quadrature signals S/sub 1/(t) and S/sub 2/(t) is digitally encoded on a real time basis by a quadrature digitizer for fractional phi (t) rotational excursions and by a quadrature up/down counter for full phi (t) rotations. The pair of quadrature signals are of the form S/sub 1/(t) = k(t) sin phi (t) and S/sub 2/(t) = k(t) cos phi (t) where k(t) is a signal common to both. The quadrature digitizer and the quadrature up/down counter may be used together or singularly as desired or required. Optionally, a digital-to-analog converter may follow the outputs of the quadrature digitizer and the quadrature up/down counter to provide an analog signal output of the quadrature phase angle phi (t).

  7. Analog quadrature signal to phase angle data conversion by a quadrature digitizer and quadrature counter

    DOEpatents

    Buchenauer, C. Jerald

    1984-01-01

    The quadrature phase angle .phi.(t) of a pair of quadrature signals S.sub.1 (t) and S.sub.2 (t) is digitally encoded on a real time basis by a quadrature digitizer for fractional .phi.(t) rotational excursions and by a quadrature up/down counter for full .phi.(t) rotations. The pair of quadrature signals are of the form S.sub.1 (t)=k(t) sin .phi.(t) and S.sub.2 (t)=k(t) cos .phi.(t) where k(t) is a signal common to both. The quadrature digitizer and the quadrature up/down counter may be used together or singularly as desired or required. Optionally, a digital-to-analog converter may follow the outputs of the quadrature digitizer and the quadrature up/down counter to provide an analog signal output of the quadrature phase angle .phi.(t).

  8. A broad band X-ray imaging spectrophotometer for astrophysical studies

    NASA Technical Reports Server (NTRS)

    Lum, Kenneth S. K.; Lee, Dong Hwan; Ku, William H.-M.

    1988-01-01

    A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

  9. Wing spar stress charts and wing truss proportions

    NASA Technical Reports Server (NTRS)

    Warner, Edward P

    1926-01-01

    In order to simplify the calculation of beams continuous over three supports, a series of charts have been calculated giving the bending moments at all the critical points and the reactions at all supports for such members. Using these charts as a basis, calculations of equivalent bending moments, representing the total stresses acting in two bay-wing trusses of proportions varying over a wide range, have been determined, both with and without allowance for column effect. This leads finally to the determination of the best proportions for any particular truss or the best strut locations in any particular airplane. The ideal proportions are found to vary with the thickness of the wing section used, the aspect ratio, and the ratio of gap to chord.

  10. Localization of activities in the human body with a whole-body counter.

    PubMed

    Fischer, H; Schlagbauer, M

    2007-01-01

    The whole-body counter of the Radiation Protection Unit at the ARC Seibersdorf research GmbH has two HP Ge-detectors for measuring radionuclides, which are internally deposited in the human body. The detector system has a scanning geometry, where one detector is placed below the bed and the other detector above the bed. The body counter is placed in a massive shielded chamber. This device is especially used for measuring radioactive exposed workers with the possibility of intake by inhalation and ingestion. In the most cases whole-body counters are calibrated with anthropomorphic phantoms where activity is homogenously distributed. However, in some cases radioactivity can be located as a 'Hot Spot' in an organ. The localisation of 'Hot spots' at least in one dimension was the topic of this work. Experiments were done by means of a water-filled bottle phantom where three point sources (137Cs, 133Ba and 60Co) were placed at different positions. Measurements show that these radionuclides can be located within 1.5 cm along the longitudinal axis of the phantom with activities for 137Cs of at least 240 Bq, 133Ba of at least 670 Bq and 60Co of at least 140 Bq.

  11. System training and assessment in simultaneous proportional myoelectric prosthesis control

    PubMed Central

    2014-01-01

    Background Pattern recognition control of prosthetic hands take inputs from one or more myoelectric sensors and controls one or more degrees of freedom. However, most systems created allow only sequential control of one motion class at a time. Additionally, only recently have researchers demonstrated proportional myoelectric control in such systems, an option that is believed to make fine control easier for the user. Recent developments suggest improved reliability if the user follows a so-called prosthesis guided training (PGT) scheme. Methods In this study, a system for simultaneous proportional myoelectric control has been developed for a hand prosthesis with two motor functions (hand open/close, and wrist pro-/supination). The prosthesis has been used with a prosthesis socket equivalent designed for normally-limbed subjects. An extended version of PGT was developed for use with proportional control. The control system’s performance was tested for two subjects in the Clothespin Relocation Task and the Southampton Hand Assessment Procedure (SHAP). Simultaneous proportional control was compared with three other control strategies implemented on the same prosthesis: mutex proportional control (the same system but with simultaneous control disabled), mutex on-off control, and a more traditional, sequential proportional control system with co-contractions for state switching. Results The practical tests indicate that the simultaneous proportional control strategy and the two mutex-based pattern recognition strategies performed equally well, and superiorly to the more traditional sequential strategy according to the chosen outcome measures. Conclusions This is the first simultaneous proportional myoelectric control system demonstrated on a prosthesis affixed to the forearm of a subject. The study illustrates that PGT is a promising system training method for proportional control. Due to the limited number of subjects in this study, no definite conclusions can be

  12. Saving Money Using Proportional Reasoning

    ERIC Educational Resources Information Center

    de la Cruz, Jessica A.; Garney, Sandra

    2016-01-01

    It is beneficial for students to discover intuitive strategies, as opposed to the teacher presenting strategies to them. Certain proportional reasoning tasks are more likely to elicit intuitive strategies than other tasks. The strategies that students are apt to use when approaching a task, as well as the likelihood of a student's success or…

  13. Understanding Proportional Reasoning for Teaching

    ERIC Educational Resources Information Center

    Kastberg, Signe E.; D'Ambrosio, Beatriz; Lynch-Davis, Kathleen

    2012-01-01

    Proportional reasoning is an important cornerstone in children's mathematical development. This sort of reasoning has been shown to develop across the early years of schooling (ages 8 to 10) through the middle years (ages 11-14). In the early years, children tend to use additive reasoning to generate solutions to problems, while later comparisons…

  14. Social Justice and Proportional Reasoning

    ERIC Educational Resources Information Center

    Simic-Muller, Ksenija

    2015-01-01

    Ratio and proportional reasoning tasks abound that have connections to real-world situations. Examples in this article demonstrate how textbook tasks can easily be transformed into authentic real-world problems that shed light on issues of equity and fairness, such as population growth and crime rates. A few ideas are presented on how teachers can…

  15. Counter-ions at single charged wall: Sum rules.

    PubMed

    Samaj, Ladislav

    2013-09-01

    For inhomogeneous classical Coulomb fluids in thermal equilibrium, like the jellium or the two-component Coulomb gas, there exists a variety of exact sum rules which relate the particle one-body and two-body densities. The necessary condition for these sum rules is that the Coulomb fluid possesses good screening properties, i.e. the particle correlation functions or the averaged charge inhomogeneity, say close to a wall, exhibit a short-range (usually exponential) decay. In this work, we study equilibrium statistical mechanics of an electric double layer with counter-ions only, i.e. a globally neutral system of equally charged point-like particles in the vicinity of a plain hard wall carrying a fixed uniform surface charge density of opposite sign. At large distances from the wall, the one-body and two-body counter-ion densities go to zero slowly according to the inverse-power law. In spite of the absence of screening, all known sum rules are shown to hold for two exactly solvable cases of the present system: in the weak-coupling Poisson-Boltzmann limit (in any spatial dimension larger than one) and at a special free-fermion coupling constant in two dimensions. This fact indicates an extended validity of the sum rules and provides a consistency check for reasonable theoretical approaches.

  16. Tribological behaviors of UHMWPE composites with different counter surface morphologies

    NASA Astrophysics Data System (ADS)

    Wang, Yanzhen; Yin, Zhongwei; Li, Hulin; Gao, Gengyuan

    2017-12-01

    The influence of counter surface morphologies on hybrid glass fiber (GF) and carbon fiber (CF) filled ultrahigh molecular weight polyethylene (UHMWPE) were studied under various contact pressure and sliding speed against GCr15 steel in dry condition. The goals were to investigate the tribological behavior of GF/CF/UHMWPE composite as a kind of water lubricated journal bearing material. The friction and wear behavior of composites were examined using a pin-on-disc tribometer. The morphologies of the worn surface were examined by scanning electron microscopy (SEM) and laser 3D micro-imaging and profile measurement. Generally, the wear rate and friction coefficient of composites increase as the increment of counter surface roughness. The friction coefficient increases firstly and then decrease with an increase in sliding speed and contact pressure for counterface with Ra=0.2 and 3.5 μm, while the friction coefficient decreased for counterface with Ra=0.6 μm.

  17. Shared address collectives using counter mechanisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blocksome, Michael; Dozsa, Gabor; Gooding, Thomas M

    A shared address space on a compute node stores data received from a network and data to transmit to the network. The shared address space includes an application buffer that can be directly operated upon by a plurality of processes, for instance, running on different cores on the compute node. A shared counter is used for one or more of signaling arrival of the data across the plurality of processes running on the compute node, signaling completion of an operation performed by one or more of the plurality of processes, obtaining reservation slots by one or more of the pluralitymore » of processes, or combinations thereof.« less

  18. Structural tailoring of counter rotation propfans

    NASA Technical Reports Server (NTRS)

    Brown, Kenneth W.; Hopkins, D. A.

    1989-01-01

    The STAT program was designed for the optimization of single rotation, tractor propfan designs. New propfan designs, however, generally consist of two counter rotating propfan rotors. STAT is constructed to contain two levels of analysis. An interior loop, consisting of accurate, efficient approximate analyses, is used to perform the primary propfan optimization. Once an optimum design has been obtained, a series of refined analyses are conducted. These analyses, while too computer time expensive for the optimization loop, are of sufficient accuracy to validate the optimized design. Should the design prove to be unacceptable, provisions are made for recalibration of the approximate analyses, for subsequent reoptimization.

  19. Improvements in estimating proportions of objects from multispectral data

    NASA Technical Reports Server (NTRS)

    Horwitz, H. M.; Hyde, P. D.; Richardson, W.

    1974-01-01

    Methods for estimating proportions of objects and materials imaged within the instantaneous field of view of a multispectral sensor were developed further. Improvements in the basic proportion estimation algorithm were devised as well as improved alien object detection procedures. Also, a simplified signature set analysis scheme was introduced for determining the adequacy of signature set geometry for satisfactory proportion estimation. Averaging procedures used in conjunction with the mixtures algorithm were examined theoretically and applied to artificially generated multispectral data. A computationally simpler estimator was considered and found unsatisfactory. Experiments conducted to find a suitable procedure for setting the alien object threshold yielded little definitive result. Mixtures procedures were used on a limited amount of ERTS data to estimate wheat proportion in selected areas. Results were unsatisfactory, partly because of the ill-conditioned nature of the pure signature set.

  20. AGBT Advanced Counter-Rotating Gearbox Detailed Design Report

    NASA Technical Reports Server (NTRS)

    Howe, D. C.; Sundt, C. V.; Mckibbon, A. H.

    1988-01-01

    An Advanced Counter-Rotating (CR) Gearbox was designed and fabricated to evaluate gearbox efficiency, durability and weight characteristics for emerging propfan-powered airplanes. Component scavenge tests showed that a constant volume collector had high scavenge effectiveness, which was uneffected by added airflow. Lubrication tests showed that gearbox losses could be reduced by controlling the air/oil mixture and by directing the oil jets radially, with a slight axial component, into the sun/planet gears.