Sample records for ultrapure water rinsing

  1. Optimal design of zero-water discharge rinsing systems.

    PubMed

    Thöming, Jorg

    2002-03-01

    This paper is about zero liquid discharge in processes that use water for rinsing. Emphasis was given to those systems that contaminate process water with valuable process liquor and compounds. The approach involved the synthesis of optimal rinsing and recycling networks (RRN) that had a priori excluded water discharge. The total annualized costs of the RRN were minimized by the use of a mixed-integer nonlinear program (MINLP). This MINLP was based on a hyperstructure of the RRN and contained eight counterflow rinsing stages and three regenerator units: electrodialysis, reverse osmosis, and ion exchange columns. A "large-scale nickel plating process" case study showed that by means of zero-water discharge and optimized rinsing the total waste could be reduced by 90.4% at a revenue of $448,000/yr. Furthermore, with the optimized RRN, the rinsing performance can be improved significantly at a low-cost increase. In all the cases, the amount of valuable compounds reclaimed was above 99%.

  2. Genesis Ultrapure Water Megasonic Wafer Spin Cleaner

    NASA Technical Reports Server (NTRS)

    Allton, Judith H.; Stansbery, Eileen K.; Calaway, Michael J.; Rodriquez, Melissa C.

    2013-01-01

    A device removes, with high precision, the majority of surface particle contamination greater than 1-micron-diameter in size from ultrapure semiconductor wafer materials containing implanted solar wind samples returned by NASA's Genesis mission. This cleaning device uses a 1.5-liter/minute flowing stream of heated ultrapure water (UPW) with 1- MHz oscillating megasonic pulse energy focused at 3 to 5 mm away from the wafer surface spinning at 1,000 to 10,000 RPM, depending on sample size. The surface particle contamination is removed by three processes: flowing UPW, megasonic cavitations, and centripetal force from the spinning wafer. The device can also dry the wafer fragment after UPW/megasonic cleaning by continuing to spin the wafer in the cleaning chamber, which is purged with flowing ultrapure nitrogen gas at 65 psi (.448 kPa). The cleaner also uses three types of vacuum chucks that can accommodate all Genesis-flown array fragments in any dimensional shape between 3 and 100 mm in diameter. A sample vacuum chuck, and the manufactured UPW/megasonic nozzle holder, replace the human deficiencies by maintaining a consistent distance between the nozzle and wafer surface as well as allowing for longer cleaning time. The 3- to 5-mm critical distance is important for the ability to remove particles by megasonic cavitations. The increased UPW sonication time and exposure to heated UPW improve the removal of 1- to 5-micron-sized particles.

  3. Bioburden control for Space Station Freedom's Ultrapure Water System

    NASA Technical Reports Server (NTRS)

    Snodgrass, Donald W.; Rodgers, Elizabeth B.; Obenhuber, Don; Huff, Tim

    1991-01-01

    Bioburden control is one of the challenges for the Ultrapure Water System on Space Station Freedom. Bioburden control must enable the system to deliver water with a low bacterial count as well as maintain biological contamination at a manageable level, to permit continued production of quality water. Ozone has been chosen as the primary means of Bioburden control. Planned tests to determine the effectiveness of ozone on free-floating microbes and biofilms are described.

  4. Bacteriological Evaluation of an Ultra-Pure Water-Distilling System

    PubMed Central

    Kayser, W. V.; Hickman, K. C. D.; Bond, W. W.; Favero, M. S.; Carson, L. A.

    1975-01-01

    A prototype distillation and storage system with recycle for producing ultrapure water was monitored for bacteriological contamination during a period of 24 months. Naturally occurring Pseudomonas aeruginosa and P. cepacia were found to grow rapidly to levels of about 105/ml in water taken from the storage reservoir and also in commercially prepared distilled water. The system was found to eliminate bacterial contaminants introduced into the still with the feed water, but the reservoir, once contaminated, remained contaminated during prolonged recycle. After a single treatment with free chlorine, the entire system remained uncontaminated until accidental or purposeful shutdown. PMID:811168

  5. Introduction to Superconducting RF Structures and the Effect of High Pressure Rinsing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajima, Tsuyoshi

    2016-06-30

    This presentation begins by describing RF superconductivity and SRF accelerating structures. Then the use of superconducting RF structures in a number of accelerators around the world is reviewed; for example, the International Linear Collider (ILC) will use ~16,000 SRF cavities with ~2,000 cryomodules to get 500 GeV e⁺/e⁻ colliding energy. Field emission control was (and still is) a very important practical issue for SRF cavity development. It has been found that high-pressure ultrapure water rinsing as a final cleaning step after chemical surface treatment resulted in consistent performance of single- and multicell superconducting cavities.

  6. Photolytic and photocatalytic degradation of quinclorac in ultrapure and paddy field water: identification of transformation products and pathways.

    PubMed

    Pareja, Lucía; Pérez-Parada, Andrés; Agüera, Ana; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2012-05-01

    Quinclorac (QNC) is an effective but rather persistent herbicide commonly used in rice production. This herbicide presents a mean persistence in the environment so its residues are considered of environmental relevance. However, few studies have been conducted to investigate its environmental behavior and degradation. In the present work, direct photolysis and TiO(2) photocatalysis of the target compound in ultrapure and paddy field water were investigated. After 10h photolysis in ultrapure water, the concentration of QNC declined 26% and 54% at 250 and 700 W m(-2), respectively. However, the amount of quinclorac in paddy field water remained almost constant under the same irradiation conditions. QNC dissipated completely after 40 min of TiO(2) photocatalysis in ultrapure water, whereas 130 min were necessary to degrade 98% of the initial concentration in paddy field water. Possible QNC photolytic and photocatalytic degradation pathways are proposed after structure elucidation of the main transformation products, through liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry and exact mass measurements. Pyridine ring hydroxylation at C-9 followed by ring opening and/or oxidative dechlorination were the key steps of QNC degradation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Prebrushing rinse with water on plaque removal: a split-mouth design.

    PubMed

    Van der Sluijs, E; Slot, D E; Hennequin-Hoenderdos, N L; Van Leeuwen, Mpc; Van der Weijden, G A

    2017-11-01

    The aim was to evaluate whether there is an additional beneficial effect on dental plaque removal of rinsing the oral cavity with water before toothbrushing. In total, 48 non-dental, systemically healthy participants ≥18 years were included in this randomized controlled clinical trial using a split-mouth design. The participants were requested to refrain from any form of oral hygiene for 48 h. First dental plaque scores (PI) were assessed full mouth. Two randomly assigned contra-lateral quadrants were brushed. Next the participant rinsed for 1 min with 15 ml water. Subsequently, the opposite two contra-lateral quadrants were brushed. Brushing was performed without toothpaste. Subsequently the second full-mouth PI assessment was performed. The brushing and rinsing procedure was performed under supervision and brushing time was tracked by a timer, each quadrant was brushed for 30 s. For the buccal, lingual, and approximal surfaces and tooth type, a subanalysis was performed. At baseline there was no statistically significantly difference between the two sets of contra-lateral quadrants. When a water rinse was used before toothbrushing the PI-score was reduced by 58%. If water rinse was used post-brushing the PI-score reduced by 57%. The difference of 0.04 in mean plaque index score reduction between the two brushing regimens was not significant(P = 0.162). When a 2 min brushing exercise was performed, on average more than 55% dental plaque was removed. Prerinsing with water did not contribute significantly to toothbrush efficacy. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Portable device for generation of ultra-pure water vapor feeds

    NASA Astrophysics Data System (ADS)

    Velin, P.; Stenman, U.; Skoglundh, M.; Carlsson, P.-A.

    2017-11-01

    A portable device for the generation of co-feeds of water vapor has been designed, constructed, and evaluated for flexible use as an add-on component to laboratory chemical reactors. The vapor is formed by catalytic oxidation of hydrogen, which benefits the formation of well-controlled minute concentrations of ultra-pure water. Analysis of the effluent stream by on-line mass spectrometry and Fourier transform infrared spectroscopy confirms that water vapor can be, with high precision, generated both rapidly and steadily over extended periods in the range of 100 ppm to 3 vol. % (limited by safety considerations) using a total flow of 100 to 1500 ml/min at normal temperature and pressure. Further, the device has been used complementary to a commercial water evaporator and mixing system to span water concentrations up to 12 vol. %. Finally, an operando diffuse reflective infrared Fourier transform spectroscopic measurement of palladium catalysed methane oxidation in the absence and presence of up to 1.0 vol. % water has been carried out to demonstrate the applicability of the device for co-feeding well-controlled low concentrations of water vapor to a common type of spectroscopic experiment. The possibilities of creating isotopically labeled water vapor as well as using tracer gases for dynamic experiments are discussed.

  9. Portable device for generation of ultra-pure water vapor feeds.

    PubMed

    Velin, P; Stenman, U; Skoglundh, M; Carlsson, P-A

    2017-11-01

    A portable device for the generation of co-feeds of water vapor has been designed, constructed, and evaluated for flexible use as an add-on component to laboratory chemical reactors. The vapor is formed by catalytic oxidation of hydrogen, which benefits the formation of well-controlled minute concentrations of ultra-pure water. Analysis of the effluent stream by on-line mass spectrometry and Fourier transform infrared spectroscopy confirms that water vapor can be, with high precision, generated both rapidly and steadily over extended periods in the range of 100 ppm to 3 vol. % (limited by safety considerations) using a total flow of 100 to 1500 ml/min at normal temperature and pressure. Further, the device has been used complementary to a commercial water evaporator and mixing system to span water concentrations up to 12 vol. %. Finally, an operando diffuse reflective infrared Fourier transform spectroscopic measurement of palladium catalysed methane oxidation in the absence and presence of up to 1.0 vol. % water has been carried out to demonstrate the applicability of the device for co-feeding well-controlled low concentrations of water vapor to a common type of spectroscopic experiment. The possibilities of creating isotopically labeled water vapor as well as using tracer gases for dynamic experiments are discussed.

  10. Ion exchange treatment of rinse water generated in the galvanizing process.

    PubMed

    Marañón, Elena; Fernández, Yolanda; Castrillón, Leonor

    2005-01-01

    A study was conducted of the viability of using the cationic exchange resins Amberlite IR-120 and Lewatit SP-112 to treat rinse water generated in the galvanizing process as well as acidic wastewater containing zinc (Zn) and iron (Fe). Solutions containing either 100 mg/L of Zn at pH 5.6 (rinse water) or Fe and Zn at concentrations of 320 and 200 mg/L at pH 1.5 (acidic water), respectively, were percolated through packed beds until the resins were exhausted. Breakthrough capacities obtained ranged between 1.1 and 1.5 meq metal/mL resin. The elution of metal and the regeneration of resins were performed with hydrochloric acid. The influence of the flowrate used during the loading stage was also studied, with 0.5 bed volumes/min (3.2 cm/min) found to be the optimum flowrate.

  11. Rapid measurement of 89,90Sr radioactivity in rinse water.

    PubMed

    Masashi, Takada; Hiroko, Enomoto; Toshikazu, Suzuki

    2013-03-01

    Rapid measurement of radioactivity from Sr in aqueous solutions is performed using a technique combining a strontium rad disk and a picobeta spectrometer. Identification of Sr radionuclides is accomplished in as little as 90 min in a radiation-tainted solution that contains more highly radioactive cesium. It is possible to perform triage by assessing skin exposure doses in this short time. This simple technique could be used in mobile laboratories. Sr having 1 Bq radioactivities are measured in 10 kBq Cs in aqueous solution. The radioactivity contained in rinse water used to decontaminate the feet of workers who stepped into highly contaminated water in the basement of the turbine building of Unit 3 at the Fukushima Daiichi nuclear power station was measured. The amount of Sr radioactivity in rinse water using the authors' rapid measurement technique (0.29 Bq mL) and a traditional method agree well, with 3.6% difference. Based on this agreement, this technique is confirmed to be useful for rapid measurement of Sr radioactivities.

  12. Cleaning Genesis Solar Wind Collectors with Ultrapure Water: Residual Contaminant Particle Analysis

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Wentworth, S. J.; Rodriquez, M. C.; Calaway, M. J.

    2008-01-01

    Additional experience has been gained in removing contaminant particles from the surface of Genesis solar wind collectors fragments by using megasonically activated ultrapure water (UPW)[1]. The curatorial facility has cleaned six of the eight array collector material types to date: silicon (Si), sapphire (SAP), silicon-on-sapphire (SOS), diamond-like carbon-on-silicon (DOS), gold-on-sapphire (AuOS), and germanium (Ge). Here we make estimates of cleaning effectiveness using image analysis of particle size distributions and an SEM/EDS reconnaissance of particle chemistry on the surface of UPW-cleaned silicon fragments (Fig. 1). Other particle removal techniques are reported by [2] and initial assessment of molecular film removal is reported by [3].

  13. ZINC SLUDGE RECYCLING AFTER KASTONE TREATMENT OF CYANIDE-BEARING RINSE WATER

    EPA Science Inventory

    The purpose of this project was to demonstrate the feasibility of reclaiming sludge. The sludge was produced by the destruction of cyanide by Kastone in zinc-cyanide dragout rinse water. The clear supernatant was discharged to the municipal sewer and the sludge eventually recycle...

  14. Tomato type and post-treatment water rinse affect efficacy of acid washes against Salmonella enterica inoculated on stem scars of tomatoes and product quality.

    PubMed

    Fan, Xuetong; Gurtler, Joshua B; Sokorai, Kimberly J B

    2018-09-02

    A study was conducted to evaluate the effects of post-treatment rinsing with water on the inactivation efficacy of acid treatments against Salmonella inoculated onto stem scar areas of two types of tomatoes. In addition, impact on fruit quality was investigated during 21 days post-treatment storage at 10 °C. A four-strain cocktail of Salmonella enterica (S. Montevideo, S. Newport, S. Saintpaul, and S. Typhimurium) was inoculated onto stem scar areas of grape and large round tomatoes. The inoculated fruits were then treated for 2 min with the following solutions: water, 2% lactic acid +2% acetic acid +2% levulinic acid, 1.7% lactic acid +1.7% acetic acid +1.7% levulinic acid, and 3% lactic acid +3% acetic acid. After treatments, half of the fruits were rinsed with water while another half were not rinsed. Non-inoculated grape tomatoes for quality analysis were treated with the same solutions with and without subsequent water rinse. Results demonstrated that the acid combinations reduced populations of Salmonella enterica on the stem scar area of grape tomatoes by 1.52-1.90 log CFU/fruit, compared with the non-treated control while water wash and rinse removed the bacterium by only 0.23-0.30 log CFU/fruit. On the stem scar of large round tomatoes, the same acid treatments achieved 3.54 log CFU/fruit reduction of the pathogen. The varying response to the acid washes between grape and large round tomatoes seems to be related to the differences in surface characteristics of stem scar areas observed with SEM. Rinsing with water after acid combination treatments did not significantly affect the efficacy of the treatments in either grape or large round tomatoes. Acidic off-odor was detected on fruits treated with acid combination without water rinse 1 day after treatment while water rinse eliminated the off-odor. The acid treatments with and without water rinse did not consistently affect appearance, color, firmness, or lycopene or ascorbic acid contents of

  15. Ultra-Pure Water and Extremophilic Bacteria interactions with Germanium Surfaces

    NASA Astrophysics Data System (ADS)

    Sah, Vasu R.

    Supported by a consortium of semiconductor industry sponsors, an international "TIE" project among 5 National Science Foundation (NSF) Industry/university Cooperative Research Centers discovered that a particular extremophilic microbe, Pseudomonas syzygii, persists in the UltraPure Water (UPW) supplies of chip fabrication facilities (FABs) and can bio-corrode germanium wafers to produce microbe-encased optically transparent crystals. Considered as potentially functional "biochips", this investigation explored mechanisms for the efficient and deliberate production of such microbe-germania adducts as a step toward later testing of their properties as sensors or switches in bioelectronic or biophotonic circuits. Recirculating UPW (Ultra-Pure Water) and other purified water, laminar-flow loops were developed across 50X20x1mm germanium (Ge) prisms, followed by subsequent examination of the prism surfaces using Multiple Attenuated Internal Reflection InfraRed (MAIR-IR) spectroscopy, Contact Potential measurements, Differential Interference Contrast Light Microscopy (DICLM), Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Analysis (EDS), and Electron Spectroscopy for Chemical Analysis (ESCA; XPS). P. syzygii cultures originally obtained from a working FAB at University of Arizona were successfully grown on R2A minimal nutrient media. They were found to be identical to the microbes in stored UPW from the same facility, such microbes routinely capable of nucleation and entrapment within GeO2 crystals on the Ge flow surfaces. Optimum flow rates and exposure times were 1 ml/minute (3.2 s-1 shear rate) for 4 days at room temperature, producing densest crystal arrays at the prism central zones 2-3 cm from the flow inlets. Other flow rates and exposure times have higher shear rate which induces a different nucleation mechanism and saturation of crystal formation. Nucleation events began with square and circular oxide deposits surrounding active attached bacteria

  16. RECYCLING NICKEL ELECTROPLATING RINSE WATERS BY LOW TEMPERATURE EVAPORATION AND REVERSE OSMOSIS

    EPA Science Inventory

    Low temperature evaporation and reverse osmosis systems were each evaluated (on a pilot scale) on their respective ability to process rinse water collected from a nickel electroplating operation. Each system offered advantages under specific operating conditions. The low temperat...

  17. Ultra-pure, water-dispersed Au nanoparticles produced by femtosecond laser ablation and fragmentation

    PubMed Central

    Kubiliūtė, Reda; Maximova, Ksenia A; Lajevardipour, Alireza; Yong, Jiawey; Hartley, Jennifer S; Mohsin, Abu SM; Blandin, Pierre; Chon, James WM; Sentis, Marc; Stoddart, Paul R; Kabashin, Andrei; Rotomskis, Ričardas; Clayton, Andrew HA; Juodkazis, Saulius

    2013-01-01

    Aqueous solutions of ultra-pure gold nanoparticles have been prepared by methods of femtosecond laser ablation from a solid target and fragmentation from already formed colloids. Despite the absence of protecting ligands, the solutions could be (1) fairly stable and poly size-dispersed; or (2) very stable and monodispersed, for the two fabrication modalities, respectively. Fluorescence quenching behavior and its intricacies were revealed by fluorescence lifetime imaging microscopy in rhodamine 6G water solution. We show that surface-enhanced Raman scattering of rhodamine 6G on gold nanoparticles can be detected with high fidelity down to micromolar concentrations using the nanoparticles. Application potential of pure gold nanoparticles with polydispersed and nearly monodispersed size distributions are discussed. PMID:23888114

  18. Bacterial communities in an ultrapure water containing storage tank of a power plant.

    PubMed

    Bohus, Veronika; Kéki, Zsuzsa; Márialigeti, Károly; Baranyi, Krisztián; Patek, Gábor; Schunk, János; Tóth, Erika M

    2011-12-01

    Ultrapure waters (UPWs) containing low levels of organic and inorganic compounds provide extreme environment. On contrary to that microbes occur in such waters and form biofilms on surfaces, thus may induce corrosion processes in many industrial applications. In our study, refined saltless water (UPW) produced for the boiler of a Hungarian power plant was examined before and after storage (sampling the inlet [TKE] and outlet [TKU] waters of a storage tank) with cultivation and culture independent methods. Our results showed increased CFU and direct cell counts after the storage. Cultivation results showed the dominance of aerobic, chemoorganotrophic α-Proteobacteria in both samples. In case of TKU sample, a more complex bacterial community structure could be detected. The applied molecular method (T-RFLP) indicated the presence of a complex microbial community structure with changes in the taxon composition: while in the inlet water sample (TKE) α-Proteobacteria (Sphingomonas sp., Novosphingobium hassiacum) dominated, in the outlet water sample (TKU) the bacterial community shifted towards the dominance of α-Proteobacteria (Rhodoferax sp., Polynucleobacter sp., Sterolibacter sp.), CFB (Bacteroidetes, formerly Cytophaga-Flavobacterium-Bacteroides group) and Firmicutes. This shift to the direction of fermentative communities suggests that storage could help the development of communities with an increased tendency toward corrosion.

  19. ETV REPORT AND VERIFICATION STATEMENT; EVALUATION OF LOBO LIQUIDS RINSE WATER RECOVERY SYSTEM

    EPA Science Inventory

    The Lobo Liquids Rinse Water Recovery System (Lobo Liquids system) was tested, under actual production conditions, processing metal finishing wastewater, at Gull Industries in Houston, Texas. The verification test evaluated the ability of the ion exchange (IX) treatment system t...

  20. Quantifying In Situ Contaminant Mobility in Marine Sediments

    DTIC Science & Technology

    2008-01-01

    and rinsing the collection and sensor chambers and the circulation subsystem with prepared solutions is followed. For metals, a nitric acid soak/rinse...fluids beginning with tap water, then de-ionized water, then a special detergent (“RBS”), then de- ionized water, then nitric acid for metals or Methanol...component parts are soaked, four-hours minimum, in each fluid. A 25% concentration of ultra-pure nitric acid is used to soak Teflon™ parts (bottles, lids

  1. Viability of sublethally injured coliform bacteria on fresh-cut cabbage stored in high CO2 atmospheres following rinsing with electrolyzed water.

    PubMed

    Izumi, Hidemi; Inoue, Ayano

    2018-02-02

    The extent of sublethally injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, was evaluated during storage in air and high CO 2 controlled atmospheres (5%, 10%, and 15%) at 5°C and 10°C using the thin agar layer (TAL) method. Sublethally injured coliform bacteria on nonrinsed shredded cabbage were either absent or they were injured at a 64-65% level when present. Rinsing of shredded cabbage with electrolyzed water containing 25ppm available chlorine reduced the coliform counts by 0.4 to 1.1 log and caused sublethal injury ranging from 42 to 77%. Pantoea ananatis was one of the species injured by chlorine stress. When shredded cabbage, nonrinsed or rinsed with electrolyzed water, was stored in air and high CO 2 atmospheres at 5°C for 7days and 10°C for 5days, coliform counts on TAL plates increased from 3.3-4.5 to 6.5-9.0 log CFU/g during storage, with the increase being greater at 10°C than at 5°C. High CO 2 of 10% and 15% reduced the bacterial growth on shredded cabbage during storage at 5°C. Although injured coliform bacteria were not found on nonrinsed shredded cabbage on the initial day, injured coliforms at a range of 49-84% were detected on samples stored in air and high CO 2 atmospheres at 5°C and 10°C. Injured cells were detected more frequently during storage at both temperatures irrespective of the CO 2 atmosphere when shredded cabbage was rinsed with electrolyzed water. These results indicated that injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, exhibited different degrees of injury during storage regardless of the CO 2 atmosphere and temperature tested. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Cleaning Surface Particle Contamination with Ultrapure Water (UPW) Megasonic Flow on Genesis Array Collectors

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Calaway, Michael J.; Hittle, J. D.; Rodriquez, M. C.; Stansbery, E. K.; McNamara, K. M.

    2006-01-01

    The hard landing experienced by the Genesis sample return capsule breached the science canister containing the solar wind collectors. This impact into the damp lakebed contaminated collector surfaces with pulverized collector and spacecraft materials and Utah sediment and brine residue. The gold foil, polished aluminum, and bulk metallic glass remained intact, but the solar wind bulk and regime-specific array collectors were jarred loose from their frames and fractured into greater than 10,000 specimens. After a year of investigation and cleaning experimentation, the Genesis Science Team determined that array collectors had 4 classes of contaminants: particles, molecular film, submicron inorganic particulate ("aerosol"), and pre-launch surface contamination. We discuss here use of megasonically energized ultrapure water (UPW) for removing particulate debris from array collector fragments.

  3. Directed flow fluid rinse trough

    DOEpatents

    Kempka, Steven N.; Walters, Robert N.

    1996-01-01

    Novel rinse troughs accomplish thorough uniform rinsing. The tanks are suitable for one or more essentially planar items having substantially the same shape. The troughs ensure that each surface is rinsed uniformly. The new troughs also require less rinse fluid to accomplish a thorough rinse than prior art troughs.

  4. Directed flow fluid rinse trough

    DOEpatents

    Kempka, S.N.; Walters, R.N.

    1996-07-02

    Novel rinse troughs accomplish thorough uniform rinsing. The tanks are suitable for one or more essentially planar items having substantially the same shape. The troughs ensure that each surface is rinsed uniformly. The new troughs also require less rinse fluid to accomplish a thorough rinse than prior art troughs. 9 figs.

  5. Rinse trough with improved flow

    DOEpatents

    O'Hern, Timothy J.; Grasser, Thomas W.

    1998-01-01

    Novel rinse troughs accomplish thorough uniform rinsing. The troughs are suitable for one or more essentially planar objects having substantially the same shape. The troughs ensure that each surface is rinsed uniformly. The new troughs provide uniform rinse fluid flow over the objects' surfaces to accomplish a more thorough rinse than prior art troughs.

  6. Rinse trough with improved flow

    DOEpatents

    O`Hern, T.J.; Grasser, T.W.

    1998-08-11

    Novel rinse troughs accomplish thorough uniform rinsing. The troughs are suitable for one or more essentially planar objects having substantially the same shape. The troughs ensure that each surface is rinsed uniformly. The new troughs provide uniform rinse fluid flow over the objects` surfaces to accomplish a more thorough rinse than prior art troughs. 5 figs.

  7. High pressure rinsing system comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Sertore; M. Fusetti; P. Michelato

    2007-06-01

    High pressure rinsing (HPR) is a key process for the surface preparation of high field superconducting cavities. A portable apparatus for the water jet characterization, based on the transferred momentum between the water jet and a load cell, has been used in different laboratories. This apparatus allows to collected quantitative parameters that characterize the HPR water jet. In this paper, we present a quantitative comparison of the different water jet produced by various nozzles routinely used in different laboratories for the HPR process

  8. Antibacterial Activity of Freshly Prepared Ozonated Water and Chlorhexidine on Mutans Streptococcus When Used as an Oral Rinse - A Randomised Clinical Study.

    PubMed

    Anumula, Lavanya; Kumar, Kv Suneel; Krishna, Chnv Murali; Lakshmi, K Sree

    2017-07-01

    Dental caries is one of the most common causes of morbidity of the tooth. Attempts have been made to reduce the pathogen population size i.e., Mutans Streptococci (MS) to demote the incidence of caries and increase the resistance of the tooth to cariogenic attack. To evaluate the antibacterial efficacy of freshly prepared ozonated water, in proposing it as an alternative mouth rinse on MS in comparison to Chlorhexidine (CHX). Subjects with high caries incidence and MS counts more than 105 Colony Forming Unit (CFU) were selected and divided by block randomization into two groups of 23 subjects each. The subjects were advised to use the respective mouth rinses under the operator surveillance, consecutively for 14 days. Stimulated salivary samples were collected from the subjects on the first day, 7 th and 14 th day to analyse the changes in MS counts during the course of use of oral rinses. The obtained data was tabulated and statistically analysed. Freshly prepared ozonated water showed a statistically significant reduction in MS counts after an interval of 7 days and 14 days when compared to CHX. Ozonated water when consecutively used as a mouth rinse resulted in a significant reduction of MS counts. Hence, it can be used as an alternative to chlorhexidine.

  9. The relationship between turbidity of mouth-rinsed water and oral health status.

    PubMed

    Takeuchi, Susumu; Ueno, Masayuki; Takehara, Sachiko; Pham, Thuy Anh Vu; Hakuta, Chiyoko; Morishima, Seiji; Shinada, Kayoko; Kawaguchi, Yoko

    2013-01-01

    The purpose of this study was to examine the relationship between turbidity of mouth rinsed water and oral health status such as dental and periodontal conditions, oral hygiene status, flow rate of saliva and oral bacteria. Subjects were 165 patients who visited the Dental Hospital, Tokyo Medical and Dental University. Oral health status, including dental and periodontal conditions, oral hygiene status and flow rate of saliva, was clinically examined. The turbidity was measured with a turbidimeter. Quantification of Fusobacterium spp, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola and total bacteria levels was performed using real-time PCR. The Pearson correlation and multiple regression analysis were used to explore the associations between the turbidity and oral health parameters. The turbidity showed significant correlations with the number of decayed teeth and deep pockets, the plaque index, extent of tongue coating and Fusobacterium spp, P. gingivalis, T. forsythia, T. denticola and total bacteria levels. In a multiple regression model, the turbidity was negatively associated with the flow rate of saliva and positively associated with the total number of bacteria (p < 0.001). Current findings suggested that turbidity of mouth rinsed water could be used as an indicator to evaluate oral health condition and the amount of bacteria in the oral cavity. In addition, the turbiditimeter appeared as a simple and objective device for screening abnormality of oral health condition at chair side as well as community-based research.

  10. Effects of rinsing with arginine bicarbonate and urea solutions on initial enamel lesions in situ.

    PubMed

    Yu, Y; Wang, X; Ge, C; Wang, B; Cheng, C; Gan, Y-H

    2017-04-01

    The aim of this study was to investigate the effects of rinsing with arginine or urea solution on initial enamel lesions in situ. Fourteen subjects who wore mandibular removable partial dentures embedded with bovine enamel blocks with artificial enamel lesions were included. The experiment included four 4-week rinsing periods with a 10-day washout period between each rinsing period. In each rinsing period, the subjects rinsed after meal or snack using water, or 2% arginine bicarbonate, or 1% urea, or 0.05% NaF solution, five times daily. The mineralization changes of the enamel lesions were assessed using quantitative light-induced fluorescence. All groups except the water group showed a statistically significant decrease in the fluorescence loss after treatment, compared with their respective baseline. Although both the arginine group and urea group showed more decrease in fluorescence loss than that of the water group, the decrease was not statistically significantly different from that of the water group. The decrease in fluorescence loss of the NaF group was statistically significant than that of the water group, arginine group, and urea group. Rinsing with arginine or urea solution offers limited remineralizing benefit to enamel lesions over a period of 4-week time. © 2016 The Authors. Oral Diseases Published by John Wiley & Sons Ltd.

  11. Rinsing with antacid suspension reduces hydrochloric acid-induced erosion.

    PubMed

    Alves, Maria do Socorro Coelho; Mantilla, Taís Fonseca; Bridi, Enrico Coser; Basting, Roberta Tarkany; França, Fabiana Mantovani Gomes; Amaral, Flávia Lucisano Botelho; Turssi, Cecilia Pedroso

    2016-01-01

    Mouthrinsing with antacids, following erosive episodes, have been suggested as a preventative strategy to minimize tooth surface loss due to their neutralizing effect. The purpose of this in situ study was to evaluate the effect of an antacid suspension containing sodium alginate, sodium bicarbonate and calcium carbonate in controlling simulated erosion of enamel of intrinsic origin. The experimental units were 48 slabs (3×3×2mm) of bovine enamel, randomly divided among 12 volunteers who wore palatal appliances with two enamel slabs. One of them was exposed extra-orally twice a day to 25mL of a hydrochloric acid (HCl) solution (0.01M, pH 2) for 2min. There were two independent phases, lasting 5 days each. In the first phase, according to a random scheme, half of the participants rinsed with 10mL of antacid suspension (Gaviscon(®), Reckitt Benckiser Healthcare Ltd.), while the remainder was rinsed with deionized water, for 1min. For the second phase, new slabs were inserted and participants switched to the treatment not received in the first stage. Therefore, the groups were as follows: (a) erosive challenge with HCl+antacid suspension; (b) erosive challenge with HCl+deionized water (DIW); (c) no erosive challenge+antacid suspension; (d) no erosive challenge+DIW. Specimens were assessed in terms of surface loss using optical profilometry and Knoop microhardness. The data were analyzed using repeated measures two-way analysis of variance and Tukey's tests. Compared to DIW rinses, surface loss of enamel was significantly lower when using an antacid rinse following erosive challenges (p=0.015). The Knoop microhardness of the enamel was significantly higher when the antacid rinse was used (p=0.026). The antacid suspension containing sodium alginate, sodium bicarbonate and calcium carbonate, rinsed after erosive challenges of intrinsic origin, reduced enamel surface loss. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. [Fluoride mouth-rinsing to prevent dental caries in a Brazilian municipality with fluoridated drinking water].

    PubMed

    Iwakura, Maria Luiza Hiromi; Morita, Maria Celeste

    2004-04-01

    To compare the prevalence of dental caries in two groups of schoolchildren: (1) schoolchildren participating in a weekly 0.2% sodium fluoride mouth-rinsing program and (2) schoolchildren not participating in the program. This cross-sectional study was conducted in the city (municipality) of Londrina, in the state of Paraná, Brazil; the city has fluoridated drinking water. We examined 367 12-year-old children: 190 participants in the weekly mouth-rinsing program (51.8%) and 177 nonparticipants (48.2%). The prevalence of caries was determined based on the scores for decayed, missing, and filled teeth and for decayed, missing, and filled surfaces. The examinations were performed by three examiners, with nearly perfect agreement in their diagnosis of caries (kappa = 0.90). The dependent variable was dental caries. The independent variables were: participation or nonparticipation in the mouth-rinsing program, attending a private school or a public school, frequency of tooth-brushing, amount of toothpaste used, consumption of sweets between meals, and visits to the dentist. The decayed, missing, and filled teeth score (mean and standard deviation) at 12 years of age was 0.85 +/- 0.059 overall, 1.0 +/- 0.058 for program participants, and 0.70 +/- 0.060 for nonparticipants. The decayed, missing, and filled surfaces score (mean and standard deviation) was 1.16 +/- 0.017, with it ranging from a low of 0.34 in one private school to a high of 1.66 in one public school. Bivariate analysis showed an association between caries (P < 0.05) and the following variables: attending a public school, participating in the mouth-rinsing program, and consuming sweets between meals more than once a day. In the multivariate analysis, attending a public school (P = 0.0004) and consuming sweets (P = 0.001) remained associated with the presence of caries. The weekly mouth-rinsing program was not associated with a decreased prevalence of caries, in either the public schools or the private

  13. In Vitro Ability of a Novel Nanohydroxyapatite Oral Rinse to Occlude Dentine Tubules

    PubMed Central

    Hill, Robert G.; Chen, Xiaohui; Gillam, David G.

    2015-01-01

    Objectives. The aim of the study was to investigate the ability of a novel nanohydroxyapatite (nHA) desensitizing oral rinse to occlude dentine tubules compared to selected commercially available desensitizing oral rinses. Methods. 25 caries-free extracted molars were sectioned into 1 mm thick dentine discs. The dentine discs (n = 25) were etched with 6% citric acid for 2 minutes and rinsed with distilled water, prior to a 30-second application of test and control oral rinses. Evaluation was by (1) Scanning Electron Microscopy (SEM) of the dentine surface and (2) fluid flow measurements through a dentine disc. Results. Most of the oral rinses failed to adequately cover the dentine surface apart from the nHa oral rinse. However the hydroxyapatite, 1.4% potassium oxalate, and arginine/PVM/MA copolymer oral rinses, appeared to be relatively more effective than the nHA test and negative control rinses (potassium nitrate) in relation to a reduction in fluid flow measurements. Conclusions. Although the novel nHA oral rinse demonstrated the ability to occlude the dentine tubules and reduce the fluid flow measurements, some of the other oral rinses appeared to demonstrate a statistically significant reduction in fluid flow through the dentine disc, in particular the arginine/PVM/MA copolymer oral rinse. PMID:26161093

  14. Cetylpyridinium chloride mouth rinses alleviate experimental gingivitis by inhibiting dental plaque maturation.

    PubMed

    Teng, Fei; He, Tao; Huang, Shi; Bo, Cun-Pei; Li, Zhen; Chang, Jin-Lan; Liu, Ji-Quan; Charbonneau, Duane; Xu, Jian; Li, Rui; Ling, Jun-Qi

    2016-09-29

    Oral rinses containing chemotherapeutic agents, such as cetylpyridinium chloride (CPC), can alleviate plaque-induced gingival infections, but how oral microbiota respond to these treatments in human population remains poorly understood. Via a double-blinded, randomised controlled trial of 91 subjects, the impact of CPC-containing oral rinses on supragingival plaque was investigated in experimental gingivitis, where the subjects, after a 21-day period of dental prophylaxis to achieve healthy gingivae, received either CPC rinses or water for 21 days. Within-subject temporal dynamics of plaque microbiota and symptoms of gingivitis were profiled via 16S ribosomal DNA gene pyrosequencing and assessment with the Mazza gingival index. Cetylpyridinium chloride conferred gingival benefits, as progression of gingival inflammation resulting from a lack of dental hygiene was significantly slower in the mouth rinse group than in the water group due to inhibition of 17 gingivitis-enriched bacterial genera. Tracking of plaque α and β diversity revealed that CPC treatment prevents acquisition of new taxa that would otherwise accumulate but maintains the original biodiversity of healthy plaques. Furthermore, CPC rinses reduced the size, local connectivity and microbiota-wide connectivity of the bacterial correlation network, particularly for nodes representing gingivitis-enriched taxa. The findings of this study provide mechanistic insights into the impact of oral rinses on the progression and maturation of dental plaque in the natural human population.

  15. Cetylpyridinium chloride mouth rinses alleviate experimental gingivitis by inhibiting dental plaque maturation

    PubMed Central

    Teng, Fei; He, Tao; Huang, Shi; Bo, Cun-Pei; Li, Zhen; Chang, Jin-Lan; Liu, Ji-Quan; Charbonneau, Duane; Xu, Jian; Li, Rui; Ling, Jun-Qi

    2016-01-01

    Oral rinses containing chemotherapeutic agents, such as cetylpyridinium chloride (CPC), can alleviate plaque-induced gingival infections, but how oral microbiota respond to these treatments in human population remains poorly understood. Via a double-blinded, randomised controlled trial of 91 subjects, the impact of CPC-containing oral rinses on supragingival plaque was investigated in experimental gingivitis, where the subjects, after a 21-day period of dental prophylaxis to achieve healthy gingivae, received either CPC rinses or water for 21 days. Within-subject temporal dynamics of plaque microbiota and symptoms of gingivitis were profiled via 16S ribosomal DNA gene pyrosequencing and assessment with the Mazza gingival index. Cetylpyridinium chloride conferred gingival benefits, as progression of gingival inflammation resulting from a lack of dental hygiene was significantly slower in the mouth rinse group than in the water group due to inhibition of 17 gingivitis-enriched bacterial genera. Tracking of plaque α and β diversity revealed that CPC treatment prevents acquisition of new taxa that would otherwise accumulate but maintains the original biodiversity of healthy plaques. Furthermore, CPC rinses reduced the size, local connectivity and microbiota-wide connectivity of the bacterial correlation network, particularly for nodes representing gingivitis-enriched taxa. The findings of this study provide mechanistic insights into the impact of oral rinses on the progression and maturation of dental plaque in the natural human population. PMID:27680288

  16. Pilot evaluation of the efficacy of shampoo treatment with ultrapure soft water for canine pruritus.

    PubMed

    Ohmori, Keitaro; Tanaka, Akane; Makita, Yuka; Takai, Masaki; Yoshinari, Yuji; Matsuda, Hiroshi

    2010-10-01

    Ultrapure soft water (UPSW) is water in which calcium and magnesium ions have been replaced with sodium ions using a cation-exchange resin. We recently demonstrated that washing with soap and UPSW reduced the clinical severity of dermatitis and improved the skin barrier function in NC/NgaTnd mice, a murine model for human atopic dermatitis. The purpose of this pilot study was to evaluate the efficacy of shampoo treatment with UPSW for dogs with pruritus. Eleven dogs with pruritus were randomly assigned to two groups depending on whether they received weekly shampoo treatment with UPSW or tap water for 4 weeks. After a washout period, the treatment protocol was switched such that each dog received both treatments. The pre-treatment and post-treatment values of the following were compared: pruritus scores assessed by the owners; dermatitis scores recorded by an investigator; and transepidermal water loss (TEWL). Shampoo treatment with UPSW significantly decreased pruritus and dermatitis scores in the dogs, whereas shampoo treatment with tap water did not. In addition, shampoo treatment with UPSW, but not with tap water, significantly reduced TEWL in the dogs. Adverse events due to the treatment were not observed in the dogs. Furthermore, we found that topical application of UPSW for barrier-disrupted skin caused by tape stripping in healthy dogs decreased TEWL more rapidly than topical application of tap water. Our findings suggest that shampoo treatment with UPSW promotes skin barrier recovery and thus could be considered as a possible therapeutic option in the management of pruritus and dermatitis in dogs. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.

  17. Linoleic acid salt with ultrapure soft water as an antibacterial combination against dermato-pathogenic Staphylococcus spp.

    PubMed

    Jang, H; Makita, Y; Jung, K; Ishizaka, S; Karasawa, K; Oida, K; Takai, M; Matsuda, H; Tanaka, A

    2016-02-01

    Skin colonization of Staphylococcus spp. critically affects the severity of dermatitis in humans and animals. We examined different types of fatty acid salts for their antibacterial activity against Staphylococcus spp. when used in ultrapure soft water (UPSW). We also evaluated their therapeutic effect on a spontaneous canine model of dermatitis. UPSW, in which Ca(++) and Mg(++) were replaced with Na(+) , was generated using a water softener with cation-exchange resin. Staphylococcus aureus (Staph. aureus), Staphylococcus intermedius (Staph. intermedius), and Staphylococcus pseudintermedius (Staph. pseudintermedius) were incubated with various fatty acid salts in distilled water (DW) or UPSW and the number of bacteria was counted. Among the fatty acids, oleic acid salt and linoleic acid (LA) salt reduced the number of these bacteria. Also, UPSW enhanced the antibacterial effect of LA on Staph. spp. In spontaneously developed itchy dermatitis in companion dogs, shampoo treatment with liquid soap containing 10% LA in UPSW improved skin conditions. LA salt showed antibacterial activity against Staph. spp. Treatment with soap containing LA with UPSW reduced clinical conditions in dogs with dermatitis. Because colonization of Staph. spp. on the skin exacerbates dermatitis, the use of LA-containing soap in UPSW may reduce unpleasant clinical symptoms of the skin. © 2015 The Society for Applied Microbiology.

  18. Removal of nickel from electroplating rinse waters using electrostatic shielding electrodialysis/electrodeionization.

    PubMed

    Dermentzis, Konstantinos

    2010-01-15

    Electrostatic shielding zones made of electrode graphite powder were used as a new type of ionic and electronic current sinks. Because of the local elimination of the applied electric field, voltage and current within the zones, ions are led inside them and accumulate there. The current sinks were implemented in electrostatic shielding electrodialysis of a simulated nickel plating rinse water containing 100 mg L(-1) nickel and electrodeionization of a 0.001 M NiSO(4) solution with simultaneous electrochemical regeneration of the ion exchange resin beds. Pure water was obtained with a Ni(2+) ion concentration of less than 0.1 mg L(-1) at a flow rate of 2.02 x 10(-4)dm(3)s(-1) diluate stream and a current density of 30 Am(-2).

  19. Modacrylic anion-exchange fibers for Cr(VI) removal from chromium-plating rinse water in batch and flow-through column experiments.

    PubMed

    Lee, Seung-Chan; Kang, Jin-Kyu; Sim, Eun-Hye; Choi, Nag-Choul; Kim, Song-Bae

    2017-11-10

    The aim of this study was to investigate Cr(VI) removal from chromium-plating rinse water using modacrylic anion-exchange fibers (KaracaronTM KC31). Batch experiments were performed with synthetic Cr(VI) solutions to characterize the KC31 fibers in Cr(VI) removal. Cr(VI) removal by the fibers was affected by solution pH; the Cr(VI) removal capacity was the highest at pH 2 and decreased gradually with a pH increase from 2 to 12. In regeneration and reuse experiments, the Cr(VI) removal capacity remained above 37.0 mg g -1 over five adsorption-desorption cycles, demonstrating that the fibers could be successfully regenerated with NaCl solution and reused. The maximum Cr(VI) removal capacity was determined to be 250.3 mg g -1 from the Langmuir model. In Fourier-transform infrared spectra, a Cr = O peak newly appeared at 897 cm -1 after Cr(VI) removal, whereas a Cr-O peak was detected at 772 cm -1 due to the association of Cr(VI) ions with ion-exchange sites. X-ray photoelectron spectroscopy analyses demonstrated that Cr(VI) was partially reduced to Cr(III) after the ion exchange on the surfaces of the fibers. Batch experiments with chromium-plating rinse water (Cr(VI) concentration = 1178.8 mg L -1 ) showed that the fibers had a Cr(VI) removal capacity of 28.1-186.4 mg g -1 under the given conditions (fiber dose = 1-10 g L -1 ). Column experiments (column length = 10 cm, inner diameter = 2.5 cm) were conducted to examine Cr(VI) removal from chromium-plating rinse water by the fibers under flow-through column conditions. The Cr(VI) removal capacities for the fibers at flow rates of 0.5 and 1.0 mL min -1 were 214.8 and 171.5 mg g -1 , respectively. This study demonstrates that KC31 fibers are effective in the removal of Cr(VI) ions from chromium-plating rinse water.

  20. Assessment of solar photocatalysis to purify on-site rinse waters from tractor cisterns used in grapevine pest control: field experimentation.

    PubMed

    Pichat, P; Vannier, S; Dussaud, J; Rubis, J P

    2005-01-01

    The aim of this study was to assess in a vineyard the effect of purifying by solar photocatalysis the title rinse waters (currently most often rejected) in terms of efficacy and on-site practicality for the wine grower. The on-site, self-functioning, solar purifying unit included a corrugated-steel inclined plate of area S = 1 m2 onto which a TiO2-coated thin material had been slightly pressed, a tank, and an aquarium-type pump powered by a photovoltaic panel (appropriate for isolated locations). For a vineyard of area A = 0.15 km2, the rinse water (about 90 L) corresponding to each of four typical vine treatments in summer was analysed (major pesticides for each treatment, TOC, Microtox test and, in one case, BOD5) by independent laboratories, before and after purification for 8 days. The S/A ratio tested was found insufficient even if the photocatalytic treatment markedly improved the quality of the rinse waters. From the relatively low final organic content reached in one case, it is calculated that a three-time higher S/A ratio might suffice, but new trials are necessary to determine whether it is valid for other typical cases. Inferred contribution of inorganic ions to the post-photocatalytic treatment toxicity points to the need for an additional detoxification. These field experiments have also demonstrated that the purifying prototype is robust, and easy to install and use on site by the wine grower.

  1. Ultra-pure soft water ameliorates atopic skin disease by preventing metallic soap deposition in NC/Tnd mice and reduces skin dryness in humans.

    PubMed

    Tanaka, Akane; Matsuda, Akira; Jung, Kyungsook; Jang, Hyosun; Ahn, Ginnae; Ishizaka, Saori; Amagai, Yosuke; Oida, Kumiko; Arkwright, Peter D; Matsuda, Hiroshi

    2015-09-01

    Mineral ions in tap water react with fatty acids in soap, leading to the formation of insoluble precipitate (metallic soap) on skin during washing. We hypothesised that metallic soap might negatively alter skin conditions. Application of metallic soap onto the skin of NC/Tnd mice with allergic dermatitis further induced inflammation with elevation of plasma immunoglobulin E and proinflammatory cytokine expression. Pruritus and dryness were ameliorated when the back of mice was washed with soap in Ca2+- and Mg2+-free ultra-pure soft water (UPSW). Washing in UPSW, but not tap water, also protected the skin of healthy volunteers from the soap deposition. Furthermore, 4 weeks of showering with UPSW reduced dryness and pruritus of human subjects with dry skin. Washing with UPSW may be therapeutically beneficial in patients with skin troubles.

  2. Decontaminating Solar Wind Samples with the Genesis Ultra-Pure Water Megasonic Wafer Spin Cleaner

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Rodriquez, M. C.; Allton, J. H.; Stansbery, E. K.

    2009-01-01

    The Genesis sample return capsule, though broken during the landing impact, contained most of the shattered ultra-pure solar wind collectors comprised of silicon and other semiconductor wafers materials. Post-flight analysis revealed that all wafer fragments were littered with surface particle contamination from spacecraft debris as well as soil from the impact site. This particulate contamination interferes with some analyses of solar wind. In early 2005, the Genesis science team decided to investigate methods for removing the surface particle contamination prior to solar wind analysis.

  3. Calcium Prerinse before Fluoride Rinse Reduces Enamel Demineralization: An in situ Caries Study.

    PubMed

    Souza, João Gabriel S; Tenuta, Livia Maria Andaló; Del Bel Cury, Altair Antoninha; Nóbrega, Diego Figueiredo; Budin, Renan R; de Queiroz, Mateus X; Vogel, Gerald L; Cury, Jaime A

    2016-01-01

    A calcium (Ca) prerinse before a fluoride (F) rinse has been shown to increase oral F levels. We tested the anticaries effect of this combination in a dose-response in situ caries model. In a double-blind, crossover experiment, 10 volunteers carried enamel slabs in palatal appliances for 14 days, during which they rinsed twice/day with one of four rinse combinations: (1) a placebo prerinse (150 mM sodium lactate) followed by a distilled water rinse (negative control); (2) a placebo prerinse followed by a 250 ppm F rinse; (3) a placebo prerinse followed by a 1,000 ppm F rinse, or (4) a Ca prerinse (150 mM Ca, as calcium lactate) followed by a 250 ppm F rinse. Sucrose solution was dripped onto the slabs 8×/day to simulate a high cariogenic challenge. The percent surface hardness loss (%SHL) was significantly lower in the Ca prerinse used with the 250 ppm F rinse group (%SHL = 38.0 ± 21.0) when compared with the F rinse alone (%SHL = 59.5 ± 24.1) and similar to the 1,000 ppm F rinse group (%SHL = 42.0 ± 18.3). Compared with the 250 ppm F rinse, the Ca prerinse increased biofilm fluid F only twice (nonsignificant). However, it greatly increased F in biofilm solids (∼22×). The Ca prerinse had little effect on loosely or firmly bound enamel F. The results showed an increased level of protection against demineralization by the use of a Ca prerinse, which seems to be caused by the enhancement of F concentration in the biofilm. © 2016 S. Karger AG, Basel.

  4. Microbiological analysis of debris from STS-42 IML-1 by direct plating of rinse waters

    NASA Technical Reports Server (NTRS)

    Smithers, G. A.

    1992-01-01

    Microbial analysis of air filter debris from the Spacelab International Microgravity Laboratory-1 (IML-1) mission was performed via direct plating of rinse waters on a battery of selective and nonselective nutrient agars. Microbial isolates were identified using Minitek and Biolog technologies. Twenty-four types of bacteria were recovered and classified; a similar number of fungal types was observed, but these were not identified. This procedure can provide information about the proportions of organism types present at the time of debris collection.

  5. Growth and Identification of Bacteria in N-Halamine Dental Unit Waterline Tubing Using an Ultrapure Water Source

    PubMed Central

    Porteous, Nuala; Luo, Jie; Hererra, Monica; Schoolfield, John; Sun, Yuyu

    2011-01-01

    This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line. PMID:22220171

  6. CLOSED-LOOP TREATMENT OF ELECTROLYTIC AND ELECTROLESS NICKEL RINSE WATER BY POINT-OF-USE ION EXCHANGE: A CASE STUDY.

    EPA Science Inventory

    Closed-Loop Treatment of Electrolytic and Electroless Nickel Rinse Water by Point-Of-Use Ion Exchange: A Case Study.

    Dave Szlag1, Joe Leonhardt2, Albert Foster1, Mike Goss1 and Paul Bolger1.
    1 U.S. EPA, National Risk Management Research Laboratory, 26 W. M. L. King D...

  7. Bonding-Compatible Corrosion Inhibitor for Rinsing Metals

    NASA Technical Reports Server (NTRS)

    Saunders, C. R.; Wurth, L. A.; Radar, A.

    2005-01-01

    A corrosion-inhibiting mixture of compounds has been developed for addition to the water used to rinse metal parts that have been cleaned with aqueous solutions in preparation for adhesive bonding of the metals to rubber and rubber-like materials. Prior to the development of this corrosion inhibitor, the parts (made, variously, of D6AC steel and 7075-T73 aluminum) were rinsed by deionized water, which caused corrosion in some places on the steel parts especially in such occluded places as sealing surfaces and threaded blind holes. An integral part of the particular cleaning process is the deposition of a thin layer of silicates and silane primers that increase the strength of the adhesive bond. The corrosion inhibitor is formulated, not only to inhibit corrosion of both D6AC steel and 7075- T73 aluminum, but also to either increase or at least not reduce the strength of the adhesive bond to be formed subsequently. The corrosion inhibitor is a mixture of sodium silicate and sodium tetraborate. The sodium silicate functions as both a corrosion inhibitor and a bond-strength promoter in association with the silane primers. The sodium tetraborate buffers the rinse solution at the optimum pH and functions as a secondary corrosion inhibitor for the steel. For a given application, the concentrations of sodium silicate and sodium tetraborate must be chosen in a compromise among the needs to inhibit corrosion of steel, inhibit corrosion of aluminum, and minimize cosmetic staining of both steel and aluminum. Concentrations of sodium silicate in excess of 150 parts of silicon per million parts of solution (ppm Si) have been determined to enhance inhibition of corrosion; unfortunately, because of the alkalinity of sodium silicate, even a small concentration can raise the pH of the rinse solution to such a level that aluminum becomes corroded despite the inhibiting effect. The pH of a solution that contains a high concentration of sodium silicate can be decreased by adding

  8. Effects of a non-rinse conditioner on the enamel of primary teeth.

    PubMed

    Fava, Marcelo; Myaki, Silvio Issáo; Arana-Chavez, Victor Elias; Fava-de-Moraes, Flavio

    2003-01-01

    The aim of this in vitro study was to evaluate by scanning electron microscopy the morphological aspects of the enamel of primary teeth after etching with 36% phosphoric acid or a non-rinse conditioner. Ten naturally exfoliated anterior primary teeth were selected. The samples were subjected to prophylaxis with pumice paste and water using a low-speed hand piece. Etching was done on the buccal surface. Specimens were divided into 2 groups: G1 (n=10): etching with 36% phosphoric acid gel - Conditioner 36 (Dentsply) for 20 s, followed by water rinse for 15 s; G2 (n=10): etching with NRC - Non Rinse Conditioner (Dentsply) for 20 s, followed by air drying for 15 s. The samples were dehydrated, mounted on metal stubs, coated with gold and observed with Jeol JSM-6100 scanning electron microscope. Electron-micrographic analysis showed that both etching agents were effective for etching the enamel of primary teeth causing the formation of microporosities on the enamel surface, although the etching pattern was more effective with the use of 36% phosphoric acid gel.

  9. The use of lithium as a marker for the retention of liquids in the oral cavity after rinsing.

    PubMed

    Hanning, Sara M; Kieser, Jules A; Ferguson, Martin M; Reid, Malcolm; Medlicott, Natalie J

    2014-01-01

    The aim of this study was to validate the use of lithium as a marker to indicate the retention of simple liquids in the oral cavity and use this to determine how much liquid is retained in the oral cavity following 30 s of rinsing. This is a validation study in which saliva was spiked with known concentrations of lithium. Twenty healthy participants then rinsed their mouths with either water or a 1 % w/v carboxymethylcellulose (CMC) solution for 30 s before expectorating into a collection cup. Total volume and concentration of lithium in the expectorant were then measured, and the percentage of liquid retained was calculated. The mean amount of liquid retained was 10.4 ± 4.7 % following rinsing with water and 15.3 ± 4.1 % following rinsing with 1 % w/v CMC solution. This difference was significant (p < 0.01). Lithium was useful as a marker for the retention of liquids in the oral cavity, and a value for the amount of water and 1 % w/v CMC solution remaining in the oral cavity following a 30-s rinse was established. The present study quantifies the retention of simple fluids in the oral cavity, validating a technique that may be applied to more complex fluids such as mouth rinses. Further, the application of this method to specific population groups such as those with severe xerostomia may assist in developing effective saliva substitutes.

  10. Handwashing and Ebola virus disease outbreaks: A randomized comparison of soap, hand sanitizer, and 0.05% chlorine solutions on the inactivation and removal of model organisms Phi6 and E. coli from hands and persistence in rinse water

    PubMed Central

    Gallandat, Karin; Daniels, Kyle; Desmarais, Anne Marie; Scheinman, Pamela; Lantagne, Daniele

    2017-01-01

    To prevent Ebola transmission, frequent handwashing is recommended in Ebola Treatment Units and communities. However, little is known about which handwashing protocol is most efficacious. We evaluated six handwashing protocols (soap and water, alcohol-based hand sanitizer (ABHS), and 0.05% sodium dichloroisocyanurate, high-test hypochlorite, and stabilized and non-stabilized sodium hypochlorite solutions) for 1) efficacy of handwashing on the removal and inactivation of non-pathogenic model organisms and, 2) persistence of organisms in rinse water. Model organisms E. coli and bacteriophage Phi6 were used to evaluate handwashing with and without organic load added to simulate bodily fluids. Hands were inoculated with test organisms, washed, and rinsed using a glove juice method to retrieve remaining organisms. Impact was estimated by comparing the log reduction in organisms after handwashing to the log reduction without handwashing. Rinse water was collected to test for persistence of organisms. Handwashing resulted in a 1.94–3.01 log reduction in E. coli concentration without, and 2.18–3.34 with, soil load; and a 2.44–3.06 log reduction in Phi6 without, and 2.71–3.69 with, soil load. HTH performed most consistently well, with significantly greater log reductions than other handwashing protocols in three models. However, the magnitude of handwashing efficacy differences was small, suggesting protocols are similarly efficacious. Rinse water demonstrated a 0.28–4.77 log reduction in remaining E. coli without, and 0.21–4.49 with, soil load and a 1.26–2.02 log reduction in Phi6 without, and 1.30–2.20 with, soil load. Chlorine resulted in significantly less persistence of E. coli in both conditions and Phi6 without soil load in rinse water (p<0.001). Thus, chlorine-based methods may offer a benefit of reducing persistence in rinse water. We recommend responders use the most practical handwashing method to ensure hand hygiene in Ebola contexts, considering

  11. Handwashing and Ebola virus disease outbreaks: A randomized comparison of soap, hand sanitizer, and 0.05% chlorine solutions on the inactivation and removal of model organisms Phi6 and E. coli from hands and persistence in rinse water.

    PubMed

    Wolfe, Marlene K; Gallandat, Karin; Daniels, Kyle; Desmarais, Anne Marie; Scheinman, Pamela; Lantagne, Daniele

    2017-01-01

    To prevent Ebola transmission, frequent handwashing is recommended in Ebola Treatment Units and communities. However, little is known about which handwashing protocol is most efficacious. We evaluated six handwashing protocols (soap and water, alcohol-based hand sanitizer (ABHS), and 0.05% sodium dichloroisocyanurate, high-test hypochlorite, and stabilized and non-stabilized sodium hypochlorite solutions) for 1) efficacy of handwashing on the removal and inactivation of non-pathogenic model organisms and, 2) persistence of organisms in rinse water. Model organisms E. coli and bacteriophage Phi6 were used to evaluate handwashing with and without organic load added to simulate bodily fluids. Hands were inoculated with test organisms, washed, and rinsed using a glove juice method to retrieve remaining organisms. Impact was estimated by comparing the log reduction in organisms after handwashing to the log reduction without handwashing. Rinse water was collected to test for persistence of organisms. Handwashing resulted in a 1.94-3.01 log reduction in E. coli concentration without, and 2.18-3.34 with, soil load; and a 2.44-3.06 log reduction in Phi6 without, and 2.71-3.69 with, soil load. HTH performed most consistently well, with significantly greater log reductions than other handwashing protocols in three models. However, the magnitude of handwashing efficacy differences was small, suggesting protocols are similarly efficacious. Rinse water demonstrated a 0.28-4.77 log reduction in remaining E. coli without, and 0.21-4.49 with, soil load and a 1.26-2.02 log reduction in Phi6 without, and 1.30-2.20 with, soil load. Chlorine resulted in significantly less persistence of E. coli in both conditions and Phi6 without soil load in rinse water (p<0.001). Thus, chlorine-based methods may offer a benefit of reducing persistence in rinse water. We recommend responders use the most practical handwashing method to ensure hand hygiene in Ebola contexts, considering the potential

  12. Carbohydrate and Caffeine Mouth Rinses Do Not Affect Maximum Strength and Muscular Endurance Performance.

    PubMed

    Clarke, Neil D; Kornilios, Evangelos; Richardson, Darren L

    2015-10-01

    Oral carbohydrate (CHO) rinsing has beneficial effects on endurance performance and caffeine (CAF) mouth rinsing either independently or in conjunction with CHO may enhance sprinting performance. However, the effects of CHO and CAF mouth rinses on resistance exercise have not been examined previously. The purpose of this study was to investigate the effects of CHO and CAF rinsing on maximum strength and muscular endurance performance. Fifteen recreationally resistance-trained males completed an exercise protocol, which involved a 1 repetition maximum (RM) bench press followed by 60% of their 1RM to failure in a double-blind, randomized, counterbalanced crossover design. Before exercise, 25 ml of a 6% (15 g; 0.20 ± 0.02 g·kg(-1)) CHO, 1.2% (300 mg; 3.9 ± 0.3 mg·kg(-1)) CAF, carbohydrate with caffeine (C + C) solutions, or water (placebo; PLA) were rinsed for 10 seconds. During the remaining session, no solution was rinsed (control; CON). All solutions were flavored with (200 mg) sucralose. Felt arousal was recorded pre- and post-rinse, and rating of perceived exertion (RPE) was recorded immediately after the repetitions to failure. There were no significant differences in 1RM (p = 0.808; ηp(2)= 0.02), the number of repetitions performed (p = 0.682; ηp(2)= 0.03), or the total exercise volume (p = 0.482; ηp(2)= 0.03) between conditions. Rating of perceived exertion was similar for all trials (p = 0.330; ηp(2)= 0.08), whereas Felt arousal increased as a consequence of rinsing (p = 0.001; ηp(2)= 0.58), but was not different between trials (p = 0.335; ηp(2)= 0.08). These results suggest that rinsing with a CHO and CAF solution either independently or combined has no significant effect on maximum strength or muscular endurance performance.

  13. Combined glucose ingestion and mouth rinsing improves sprint cycling performance.

    PubMed

    Chong, Edwin; Guelfi, Kym J; Fournier, Paul A

    2014-12-01

    This study investigated whether combined ingestion and mouth rinsing with a carbohydrate solution could improve maximal sprint cycling performance. Twelve competitive male cyclists ingested 100 ml of one of the following solutions 20 min before exercise in a randomized double-blinded counterbalanced order (a) 10% glucose solution, (b) 0.05% aspartame solution, (c) 9.0% maltodextrin solution, or (d) water as a control. Fifteen min after ingestion, repeated mouth rinsing was carried out with 11 × 15 ml bolus doses of the same solution at 30-s intervals. Each participant then performed a 45-s maximal sprint effort on a cycle ergometer. Peak power output was significantly higher in response to the glucose trial (1188 ± 166 W) compared with the water (1036 ± 177 W), aspartame (1088 ± 128 W) and maltodextrin (1024 ± 202 W) trials by 14.7 ± 10.6, 9.2 ± 4.6 and 16.0 ± 6.0% respectively (p < .05). Mean power output during the sprint was significantly higher in the glucose trial compared with maltodextrin (p < .05) and also tended to be higher than the water trial (p = .075). Glucose and maltodextrin resulted in a similar increase in blood glucose, and the responses of blood lactate and pH to sprinting did not differ significantly between treatments (p > .05). These findings suggest that combining the ingestion of glucose with glucose mouth rinsing improves maximal sprint performance. This ergogenic effect is unlikely to be related to changes in blood glucose, sweetness, or energy sensing mechanisms in the gastrointestinal tract.

  14. Discoloration of Provisional Restorations after Oral Rinses

    PubMed Central

    Turgut, Sedanur; Bagis, Bora; Ayaz, Elif Aydogan; Ulusoy, Kıvanç Utku; Altintas, Subutay Han; Korkmaz, Fatih Mehmet; Bagis, Nilsun

    2013-01-01

    Purpose: Oral rinses are widely used to promote periodontal health with provisional restorations during the interim period. The aim of this study was to compare the discoloration of provisional restoration materials with different oral rinses. Material and Methods: A total of 140 disc-shaped specimens (shade A2) (10 mm x 2 mm) were prepared from one PMMA-based (TemDent Classic®) and three different bis-acrylic-based (Protemp II®, Luxatemp® and Fill-In®) provisional restoration materials (n=7). The color values (L*, a*, and b*) of each specimen were measured before and after exposure with a colorimeter, and the color changes (∆E) were calculated according to the CIE L*a*b* system. The specimens were immersed in each of the 4 oral rinses (alcohol-containing mouthwash, chlorhexidine, benzydamine HCl, benzydamine HCl and chlorhexidine) twice a day for 2 minutes. After 2 minutes of immersion in the oral rinses, the specimens were immersed in artificial saliva. The specimens were exposed to the oral rinses and the artificial saliva for 3 weeks. Two-way ANOVA, the Bonferroni test and the paired sample t-test were used for statistical analyses (p<0.05). Results: Comparison of the discoloration from the oral rinses after immersion for three weeks revealed no significant differences (p>0.05). The lowest color change was observed in PMMA-based Temdent in all oral rinses (p<0.05). There were no significant differences between the bis-acryl composites after immersion in saliva or the mixture of benzydamine HCl and chlorhexidine and the alcohol-containing mouthwash for 3 weeks (p>0.05). After immersion in chlorhexidine, the color change values of Protemp II and Fill-in showed significant differences (p=0.018). Protemp II also showed less discoloration than the other bis-acryl composites, and this color change was statistically significant (p <0.05). For all oral rinses, the L* value decreased while b* values increased, and this color change was found to be statistically

  15. Disinfection of syringes contaminated with hepatitis C virus by rinsing with household products.

    PubMed

    Binka, Mawuena; Paintsil, Elijah; Patel, Amisha; Lindenbach, Brett D; Heimer, Robert

    2015-01-01

    Background.  Hepatitis C virus (HCV) transmission among people who inject drugs (PWID) is associated with the sharing of injection paraphernalia. People who inject drugs often "disinfect" used syringes with household products when new syringes are unavailable. We assessed the effectiveness of these products in disinfecting HCV-contaminated syringes. Methods.  A genotype-2a reporter virus assay was used to assess HCV infectivity in syringes postrinsing. Hepatitis C virus-contaminated 1 mL insulin syringes with fixed needles and 1 mL tuberculin syringes with detachable needles were rinsed with water, Clorox bleach, hydrogen peroxide, ethanol, isopropanol, Lysol, or Dawn Ultra at different concentrations. Syringes were either immediately tested for viable virus or stored at 4°C, 22°C, and 37°C for up to 21 days before viral infectivity was determined. Results.  Most products tested reduced HCV infectivity to undetectable levels in insulin syringes. Bleach eliminated HCV infectivity in both syringes. Other disinfectants produced virus recovery ranging from high (5% ethanol, 77% ± 12% HCV-positive syringes) to low (1:800 Dawn Ultra, 7% ± 7% positive syringes) in tuberculin syringes. Conclusions.  Household disinfectants tested were more effective in fixed-needle syringes (low residual volume) than in syringes with detachable needles (high residual volume). Bleach was the most effective disinfectant after 1 rinse, whereas other diluted household products required multiple rinses to eliminate HCV. Rinsing with water, 5% ethanol (as in beer), and 20% ethanol (as in fortified wine) was ineffective and should be avoided. Our data suggest that rinsing of syringes with household disinfectants may be an effective tool in preventing HCV transmission in PWID when done properly.

  16. Disinfection of Syringes Contaminated With Hepatitis C Virus by Rinsing With Household Products

    PubMed Central

    Binka, Mawuena; Paintsil, Elijah; Patel, Amisha; Lindenbach, Brett D.; Heimer, Robert

    2015-01-01

    Background. Hepatitis C virus (HCV) transmission among people who inject drugs (PWID) is associated with the sharing of injection paraphernalia. People who inject drugs often “disinfect” used syringes with household products when new syringes are unavailable. We assessed the effectiveness of these products in disinfecting HCV-contaminated syringes. Methods. A genotype-2a reporter virus assay was used to assess HCV infectivity in syringes postrinsing. Hepatitis C virus-contaminated 1 mL insulin syringes with fixed needles and 1 mL tuberculin syringes with detachable needles were rinsed with water, Clorox bleach, hydrogen peroxide, ethanol, isopropanol, Lysol, or Dawn Ultra at different concentrations. Syringes were either immediately tested for viable virus or stored at 4°C, 22°C, and 37°C for up to 21 days before viral infectivity was determined. Results. Most products tested reduced HCV infectivity to undetectable levels in insulin syringes. Bleach eliminated HCV infectivity in both syringes. Other disinfectants produced virus recovery ranging from high (5% ethanol, 77% ± 12% HCV-positive syringes) to low (1:800 Dawn Ultra, 7% ± 7% positive syringes) in tuberculin syringes. Conclusions. Household disinfectants tested were more effective in fixed-needle syringes (low residual volume) than in syringes with detachable needles (high residual volume). Bleach was the most effective disinfectant after 1 rinse, whereas other diluted household products required multiple rinses to eliminate HCV. Rinsing with water, 5% ethanol (as in beer), and 20% ethanol (as in fortified wine) was ineffective and should be avoided. Our data suggest that rinsing of syringes with household disinfectants may be an effective tool in preventing HCV transmission in PWID when done properly. PMID:26034767

  17. The use of a rotating cylinder electrode to recover zinc from rinse water generated by the electroplating industry.

    PubMed

    Matlalcuatzi, Sairi; Nava, José L

    2012-01-01

    This work concerns the application of a laboratory scale rotating cylinder electrode (RCE) to recover zinc from rinse water generated by the electrolytic zinc process (initially 1,300, 4,400, 50, 20 mg L(-1) of Zn(II), Fe(III), Ag(I) and Cr(VI), respectively, at pH 2), although it is also applicable to other electroplating industries. Experimental results demonstrated the convenience of the removal of ferric ions, as (Fe(OH)(3(s))) by a pH adjustment to 4, before zinc electro recovery on the RCE. The generation of smooth zinc deposits on the RCE was obtained at Reynolds numbers within the range of 15,000 ≤ Re ≤ 124,000 and limiting current densities (J(L)) in the interval of -4.8 to -13 mA cm(-2). The zinc recovery reached a conversion of 67% in 90 min of electrolysis for Re = 124,000 and J = -13 mA cm(-2), 21% current efficiency, and energy consumption of 9.5 kWh m(-3). The treated solution can be recycled back through the same rinsing process.

  18. AN ENVIRONMENTAL AND ECONOMIC COMPARISON OF ION EXCHANGE AND RECENTLY COMMERCIALIZED ELECTROCHEMICAL TECHNOLOGIES FOR THE RECOVERY OF RINSE WATER IN BRIGHT NICKEL PLATING FACILITY

    EPA Science Inventory

    Researchers at USEPA are testing and evaluating two commercial electrochemical technologies for the purification of rinse water and the recovery of copper and nickel from a variety of electroplating processes. One of the investigated technologies is based on the application of hi...

  19. Faecal contamination of water and fingertip-rinses as a method for evaluating the effect of low-cost water supply and sanitation activities on faeco-oral disease transmission. I. A case study in rural north-east Thailand.

    PubMed Central

    Pinfold, J. V.

    1990-01-01

    Most villagers in north-east Thailand carry water to their homes and store it in separate containers depending on its subsequent use. In one village, information on water use was collated with the bacteriological quality of stored water, water sources and fingertip-rinses. Stored water quality was a function of water-related activities rather than quality at source (P less than 0.0001). Specifically water used for toilet, washing dishes and cooking-related activities was much more contaminated with faecal bacteria than that used for drinking and cooking. Salmonella spp. was significantly more common in water used for washing dishes than drinking (P less than 0.05). Escherichia coli contamination of fingertip-rinses was strongly associated with the individual's activity prior to testing (P less than 0.0001); child care, food and water-related activities produced much higher levels of fingertip contamination than others. Dirty utensils used for cooking and eating were usually left to soak and faecal bacterial growth occurred in this grossly contaminated soak-water. Cross-contamination via water handling was the main mechanism of stored water pollution. These results were used to develop a hygiene intervention study presented in a companion paper. PMID:2209740

  20. Low-level (PPB) determination of cisplatin in cleaning validation (rinse water) samples. II. A high-performance liquid chromatographic method.

    PubMed

    Raghavan, R; Burchett, M; Loffredo, D; Mulligan, J A

    2000-04-01

    A high-performance liquid chromatographic (HPLC) method is described for the determination of residual levels of cisplatin from extracts of surfaces with very low surface area; from extracts of surfaces of coupons made of Teflon (polytetrafluoroethylene, PTFE), stainless steel, and glass; and in aqueous solution collected after rinsing equipment and parts. Initially, the method was developed to determine cisplatin at concentrations ranging from 20 to 200 ng/ml by direct injection. Retaining the same method conditions, the scope of the method was expanded by the addition of a sample preconcentration step, allowing analyses at levels ranging from 0.5 ng to 20 ng/ml. Preconcentration is necessary for the determination of cisplatin in rinse waters at a quantifiable concentration of about 2 PPB. Under these conditions, the detection limit is about 0.2 to 0.3 ng/ml. Residual cisplatin on different types of surfaces, including surfaces with very low surface area, can be determined by swabbing each test surface with a derivatizing solution. The cisplatin recovered in the swabbing solution can be analyzed by HPLC using direct injection or preconcentration, depending on the expected level of cisplatin in the sample. Initial methods were developed to quantitate at a cisplatin concentration of about 100 PPB or higher in solution extracted from surfaces. However, when surface areas are limited because of the size of the parts, solution concentration becomes very low as a result of the minimum volume required for extraction. To support the application of swabbing techniques to surface analysis, stainless steel, Teflon, and glass surfaces were spiked with cisplatin at 2.5 to 20 ng/cm2. Satisfactory overall recoveries of 90% +/- 10% were obtained from all surfaces. Cisplatin has no ultraviolet/visible (UV/Vis) spectral-active functional group that can be used to detect low levels of cisplatin. Hence, diethyldithiocarbamate (DDTC) was used as a derivatizing agent to increase

  1. Whitening Efficacy of Whitening Mouth Rinses Used Alone or in Conjunction With Carbamide Peroxide Home Whitening.

    PubMed

    Oliveira, Jbs; Sarlo, R S; Bresciani, E; Caneppele, Tmf

    The aim of this study was to compare the effectiveness of whitening mouth rinses on teeth previously whitened or not, exposed to food dyes. One hundred twenty enamel-dentin specimens, 3 mm in diameter, were obtained from bovine incisors. The specimens were stained for 14 days in staining broth. After staining, the initial color reading was performed via a spectrophotometer CM-2600d (Konica Minolta). Half of specimens were submitted to whitening (10% carbamide peroxide [CP]) for 14 days. They were then divided into three groups and were submitted to cycles of staining (five minutes) and mouth rinses (two minutes) for 12 weeks, with the following: CP-LI, Listerine Whitening; CP-PL, Plax Whitening; CP-BP, bromelain + papain; CP-DW, deionized water. LI, PL, BP, and DW groups were submitted to the same cited cycles but with no prior bleaching. The color measurements were performed after four, eight, and 12 weeks of treatment with mouth rinses. Data were submitted to repeated measures analysis of variance (ANOVA) and Tukey's test for multiple comparisons, with significance level at 5%. The results showed that the CP-LI, CP-PL, LI, and PL groups had greater color change than did the others. The CP-BP and BP groups were similar to CP-DW and DW. We therefore conclude that Listerine Whitening mouth rinse presented the highest bleaching effect, followed by Plax Whitening mouth rinse. Both maintained CP bleaching effect after 12 weeks of dye-rinse cycles. However, none of these rinses were able to produce whitening similar to CP. Bromelain- and papain-containing mouth rinses did not show bleaching effect, being similar to the control groups.

  2. Type of tomatoes and water rinse affect efficacy of acid washes against salmonella enterica inoculated on stem scar areas of tomatoes and on product quality

    USDA-ARS?s Scientific Manuscript database

    The study was conducted to evaluate the effects of post-treatment rinsing with water on the inactivation efficacy of acid treatments against Salmonella inoculated onto stem scar areas of two types of tomatoes. In addition, impact on fruit quality was investigated during 21 days post-treatment storag...

  3. Ultrapure Water System for Hemodialysis Therapy

    ClinicalTrials.gov

    2011-07-21

    The Change of Biomarkers CRP, CBC With the Use of Ultra Pure Water System for; Hemodialysis.; The Rate of Adverse Events Such as Hypotension During Hemodialysis Therapy With Ultra Pure Water; System as Compared to Conventional Water System.

  4. Note: Influence of rinsing and drying routines on growth of multilayer thin films using automated deposition system.

    PubMed

    Gamboa, Daniel; Priolo, Morgan A; Ham, Aaron; Grunlan, Jaime C

    2010-03-01

    A versatile, high speed robot for layer-by-layer deposition of multifunctional thin films, which integrates concepts from previous dipping systems, has been designed with dramatic improvements in software, positioning, rinsing, drying, and waste removal. This system exploits the electrostatic interaction of oppositely charged species to deposit nanolayers (1-10 nm thick) from water onto the surface of a substrate. Dip times and number of deposited layers are adjustable through a graphical user interface. In between dips the system spray rinses and dries the substrate by positioning it in the two-tiered rinse-dry station. This feature significantly reduces processing time and provides the flexibility to choose from four different procedures for rinsing and drying. Assemblies of natural montmorillonite clay and polyethylenimine are deposited onto 175 microm poly(ethylene terephthalate) film to demonstrate the utility of this automated deposition system. By altering the type of rinse-dry procedure, these clay-based assemblies are shown to exhibit variations in film thickness and oxygen transmission rate. This type of system reproducibly deposits films containing 20 or more layers and may also be useful for other types of coatings that make use of dipping.

  5. Longevity of Self-etch Dentin Bonding Adhesives Compared to Etch-and-rinse Dentin Bonding Adhesives: A Systematic Review.

    PubMed

    Masarwa, Nader; Mohamed, Ahmed; Abou-Rabii, Iyad; Abu Zaghlan, Rawan; Steier, Liviu

    2016-06-01

    A systematic review and meta-analysis were performed to compare longevity of Self-Etch Dentin Bonding Adhesives to Etch-and-Rinse Dentin Bonding Adhesives. The following databases were searched for PubMed, MEDLINE, Web of Science, CINAHL, the Cochrane Library complemented by a manual search of the Journal of Adhesive Dentistry. The MESH keywords used were: "etch and rinse," "total etch," "self-etch," "dentin bonding agent," "bond durability," and "bond degradation." Included were in-vitro experimental studies performed on human dental tissues of sound tooth structure origin. The examined Self-Etch Bonds were of two subtypes; Two Steps and One Step Self-Etch Bonds, while Etch-and-Rinse Bonds were of two subtypes; Two Steps and Three Steps. The included studies measured micro tensile bond strength (μTBs) to evaluate bond strength and possible longevity of both types of dental adhesives at different times. The selected studies depended on water storage as the aging technique. Statistical analysis was performed for outcome measurements compared at 24 h, 3 months, 6 months and 12 months of water storage. After 24 hours (p-value = 0.051), 3 months (p-value = 0.756), 6 months (p-value=0.267), 12 months (p-value=0.785) of water storage self-etch adhesives showed lower μTBs when compared to the etch-and-rinse adhesives, but the comparisons were statistically insignificant. In this study, longevity of Dentin Bonds was related to the measured μTBs. Although Etch-and-Rinse bonds showed higher values at all times, the meta-analysis found no difference in longevity of the two types of bonds at the examined aging times. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Validation of a 2 percent lactic acid antimicrobial rinse for mobile poultry slaughter operations.

    PubMed

    Killinger, Karen M; Kannan, Aditi; Bary, Andy I; Cogger, Craig G

    2010-11-01

    Poultry processing antimicrobial interventions are critical for pathogen control, and organic, mobile operations in Washington seek alternatives to chlorine. Laboratory and field studies (three replications each) evaluated lactic acid efficacy as a chlorine alternative. For the laboratory study, retail-purchased, conventionally processed chicken wings inoculated with Salmonella were randomly assigned to the following treatments: Salmonella inoculation followed by no treatment (10 wings) or by 3-min rinses of water, 50 to 100 ppm of chlorine, or 2% lactic acid (20 wings for each rinse treatment). Wings were sampled for Salmonella enumeration on xylose lysine desoxycholate agar. During pastured poultry processing at mobile slaughter units for each field study replication, 20 chicken carcasses were randomly assigned to each treatment: untreated control or 3-min immersion in lactic acid or chlorine. Whole-carcass rinses were examined for aerobic plate count (APC) on tryptic soy agar and coliforms on violet red bile agar. Untreated controls were also examined for Salmonella. In the laboratory study, lactic acid produced a significant (P < 0.01) Salmonella reduction compared with the inoculated no-rinse, water, and chlorine treatments, which were statistically similar to each other. In the field study, no Salmonella was detected on untreated controls. Lactic acid produced significant >2-log (P < 0.01) reductions in APC and coliforms, whereas chlorine resulted in slight, but significant 0.4-log reductions (P < 0.01) and 0.21-log reductions (P < 0.05) in APC and coliforms compared with untreated controls. Considering laboratory and field studies, lactic acid produced greater reductions in Salmonella, APC, and coliforms, validating its effectiveness as a chlorine alternative in mobile poultry slaughter operations.

  7. Saline Sinus Rinse Recipe

    MedlinePlus

    ... Menu Search Main navigation Skip to content Conditions & Treatments Allergies Asthma Primary Immunodeficiency Disease Related Conditions Drug Guide ... Expert Search Search AAAAI Breadcrumb navigation Home ▸ Conditions & Treatments ▸ Library ▸ Allergy Library ▸ Saline Sinus Rinse Recipe Share | Saline Sinus ...

  8. The effect of different mouth rinse products on intra-oral halitosis.

    PubMed

    Erovic Ademovski, S; Lingström, P; Renvert, S

    2016-05-01

    To evaluate the effect of different mouth rinses 12 h after rinsing on genuine intra-oral halitosis. Twenty-four adults with halitosis were included in a double-blind, crossover, randomized clinical trial. Halitosis was evaluated 12 h after rinsing with placebo and five mouth rinse products containing zinc acetate and chlorhexidine diacetate; zinc lactate, chlorhexidine and cetylpyridinium chloride; zinc acetate and chlorhexidine diacetate with reduced amounts of mint and menthol; zinc chloride and essential oil; and chlorine dioxide using the organoleptic method and a gas chromatograph. Test periods were separated by 1 week. Hydrogen sulphide (H2 S), methyl mercaptan (MM) and the organoleptic scores (OLS) were significantly reduced 12 h following rinsing with all substances compared to placebo (P < 0.05). H2 S was more effectively reduced after rinsing with zinc acetate and chlorhexidine diacetate and zinc acetate and chlorhexidine diacetate with reduced amounts of mint and menthol compared to rinsing with zinc chloride and essential oil (P < 0.05), and significantly lower values of MM were obtained after rinsing with zinc acetate and chlorhexidine diacetate compared to zinc lactate, chlorhexidine and cetylpyridinium chloride (P < 0.05). The percentage effectively treated individuals (H2 S (<112 ppb), MM (<26 ppb) and OLS score <2) varied from 58% percentage (zinc acetate and chlorhexidine diacetate) to 26% (zinc chloride and essential oil). All treatments resulted in reduction in halitosis 12 h after rinsing compared to placebo. H2 S and MM were most effectively reduced by zinc acetate and chlorhexidine diacetate. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Self-etch and etch-and-rinse adhesive systems in clinical dentistry.

    PubMed

    Ozer, Fusun; Blatz, Markus B

    2013-01-01

    Current adhesive systems follow either an "etch-and-rinse" or "self-etch" approach, which differ in how they interact with natural tooth structures. Etch-and-rinse systems comprise phosphoric acid to pretreat the dental hard tissues before rinsing and subsequent application of an adhesive. Self-etch adhesives contain acidic monomers, which etch and prime the tooth simultaneously. Etch-and-rinse adhesives are offered as two- or three-step systems, depending on whether primer and bonding are separate or combined in a single bottle. Similarly, self-etch adhesives are available as one- or two-step systems. Both etch-and-rinse and self-etch systems form a hybrid layer as a result of resins impregnating the porous enamel or dentin. Despite current trends toward fewer and simpler clinical application steps, one-step dentin bonding systems exhibit bonding agent lower bond strengths and seem less predictable than multi-step etch-and-rinse and self-etch systems. The varying evidence available today suggests that the choice between etch-and-rinse and self-etch systems is often a matter of personal preference. In general, however, phosphoric acid creates a more pronounced and retentive etching pattern in enamel. Therefore, etch-and-rinse bonding systems are often preferred for indirect restorations and when large areas of enamel are still present. Conversely, self-etch adhesives provide superior and more predictable bond strength to dentin and are, consequently, recommended for direct composite resin restorations, especially when predominantly supported by dentin.

  10. Neutralization of bactericidal activity related to antimicrobial carry-over in broiler carcass rinse samples

    USDA-ARS?s Scientific Manuscript database

    Chemical antimicrobial interventions used as poultry processing aids may have potential for carry-over into whole poultry carcass buffered peptone water (BPW) rinses collected for the recovery of viable Salmonella. Such carry-over may lead to false negative indications due to continuing bactericidal...

  11. Antiseptic mouth rinses: an update on comparative effectiveness, risks and recommendations.

    PubMed

    Osso, Diane; Kanani, Nehal

    2013-02-01

    Antiseptic mouth rinses are widely recommended and marketed to improve oral health. This article summarizes current studies on the comparative effectiveness of selected antiseptic mouth rinses in controlling plaque and gingivitis, as well as risks associated with daily exposure, including salivary flow rate, oral cancer and wear of composite restorations. Electronic database searches were conducted using Google Scholar and PubMed to identify articles comparing the effectiveness of 4 commercially marketed antiseptic mouth rinses differing in active ingredients (0.12% chlorhexidine gluconate, essential oils (menthol, thymol and eucalyptol) and methyl salicylate, 0.7% cetylpyridinium chloride and 20% aloe vera gel) for controlling plaque and gingivitis. Criteria for inclusion included controlled clinical trials and systematic reviews appearing in English language publications evaluating the comparative effectiveness of the mouth rinses in controlling plaque and gingivitis, as well as risks associated with daily usage. The majority of studies have shown mouth rinses containing chlorhexidine gluconate or essential oils and methyl salicylate provide clinically significant anti-gingivitis and anti-plaque benefits. Cetylpyridinium chloride has been found to provide only limited clinical benefits compared to inactive control mouth rinse. Inadequate evidence is available to evaluate the clinical effectiveness of aloe vera gel. Chlorhexidine, essential oils and cetylpyridinium have been found to be safe. However, limited data are available on the effects of the mouth rinse on wear patterns of dental restorations. Studies reviewed reported no significant difference in salivary flow rate related to alcohol based mouth rinse. Research supports the effectiveness of antiseptic mouth rinses in reducing plaque and gingivitis as an adjunct to home care. Insufficient evidence is available to support the claim that oral antiseptics can reduce the risk of developing periodontitis or the

  12. Relationship of a turbidity of an oral rinse with oral health and malodor in Vietnamese patients.

    PubMed

    Pham, Thuy A V

    2014-05-01

    In the present study, the relationship between the turbidity of mouth-rinse water and oral health conditions, including oral malodor, in patients with (n = 148) and without (n = 231) periodontitis was examined. The turbidity of 20 mL distilled water that the patients rinsed in their mouths 10 times was measured using a turbidimeter. Oral malodor was evaluated using an organoleptic test and Oral Chroma. Oral health conditions, including decayed teeth, periodontal status, oral hygiene status, proteolytic activity of the N-benzoyl-dl-arginine-2-napthilamide (BANA) test on the tongue coating, and salivary flow rate, were assessed. Turbidity showed significant correlations with oral malodor and all oral health parameters in the periodontitis group. In the non-periodontitis group, turbidity showed significant correlations with oral malodor and oral health parameters, including dental plaque, tongue coating, BANA test, and salivary flow rate. The regression analysis indicated that turbidity was significantly associated with methyl mercaptan and the BANA test in the periodontitis group, and with hydrogen sulfide, dental plaque, tongue coating, and salivary flow rate in the non-periodontitis group. The findings of the present study indicate that the turbidity of mouth-rinse water could be used as an indicator of oral health conditions, including oral malodor. © 2013 Wiley Publishing Asia Pty Ltd.

  13. Effect of rubber stopper composition, preservative pretreatment and rinse water temperature on the moist heat resistance of Bacillus stearothermophilus ATCC 12980.

    PubMed

    Rubio, S L; Moldenhauer, J E

    1995-01-01

    Bacillus stearothermophilus spores (liquid suspension) were inoculated onto rubber stoppers and exposed to sublethal steam sterilization cycles at 120 degrees C. The D-values were determined using the fraction-negative method. An increase in heat resistance (D-value) of 200%-400% was observed when the spore suspension was inoculated onto rubber stoppers. The D-values ranged from 4.90-6.96 minutes 120 degrees C. No significant effect was seen when different preservatives were added to the stoppers nor when hot or cold rinse water temperatures were used after processing.

  14. Effects of caffeine and carbohydrate mouth rinses on repeated sprint performance.

    PubMed

    Beaven, C Martyn; Maulder, Peter; Pooley, Adrian; Kilduff, Liam; Cook, Christian

    2013-06-01

    Our purpose was to examine the effectiveness of carbohydrate and caffeine mouth rinses in enhancing repeated sprint ability. Previously, studies have shown that a carbohydrate mouth rinse (without ingestion) has beneficial effects on endurance performance that are related to changes in brain activity. Caffeine ingestion has also demonstrated positive effects on sprint performance. However, the effects of carbohydrate or caffeine mouth rinses on intermittent sprints have not been examined previously. Twelve males performed 5 × 6-s sprints interspersed with 24 s of active recovery on a cycle ergometer. Twenty-five milliliters of either a noncaloric placebo, a 6% glucose, or a 1.2% caffeine solution was rinsed in the mouth for 5 s prior to each sprint in a double-blinded and balanced cross-over design. Postexercise maximal heart rate and perceived exertion were recorded, along with power measures. A second experiment compared a combined caffeine-carbohydrate rinse with carbohydrate only. Compared with the placebo mouth rinse, carbohydrate substantially increased peak power in sprint 1 (22.1 ± 19.5 W; Cohen's effect size (ES), 0.81), and both caffeine (26.9 ± 26.9 W; ES, 0.71) and carbohydrate (39.1 ± 25.8 W; ES, 1.08) improved mean power in sprint 1. Experiment 2 demonstrated that a combination of caffeine and carbohydrate improved sprint 1 power production compared with carbohydrate alone (36.0 ± 37.3 W; ES, 0.81). We conclude that carbohydrate and (or) caffeine mouth rinses may rapidly enhance power production, which could have benefits for specific short sprint exercise performance. The ability of a mouth-rinse intervention to rapidly improve maximal exercise performance in the absence of fatigue suggests a central mechanism.

  15. Effect of an essential oil-containing mouth rinse on VSC-producing bacteria on the tongue.

    PubMed

    Thaweboon, Sroisiri; Thaweboon, Boonyanit

    2011-03-01

    The objective of the present study was to investigate the inhibitory effect of a commercially available essential oil-containing mouth rinse 12 hours after a single rinse and two weeks of twice daily rinsing, on volatile sulphur compounds (VSC) producing bacteria on the tongue. The study was a randomized, double-blind, controlled crossover design. Thirty-six healthy subjects, aged 20-48 years, volunteered to participate in the study. Subjects were randomly assigned to rinse twice daily with either an essential oil-containing mouth rinse (Cool Mint Listerine Antiseptic) or a negative control rinse. Bacteria samples were taken from the dorsum of the tongue at baseline, after the first rinse and two weeks later. They were plated on OOPS medium to enumerate the VSC-producing bacteria. Intergroup comparisons of log10 transformed colony-forming units of the samples were made using analysis of covariance. Each comparison was performed at a 5% significance level. The mean VSC-producing bacteria in subjects using the essential oil mouth rinse were significantly lower than those using the control rinse twice daily. In healthy subjects, rinsing with an essential oil-containing mouth rinse can have a significant effect on VSC-producing bacteria on the tongue and may be useful for controlling intrinsic oral malodor over prolonged periods.

  16. A caffeine-maltodextrin mouth rinse counters mental fatigue.

    PubMed

    Van Cutsem, Jeroen; De Pauw, Kevin; Marcora, Samuele; Meeusen, Romain; Roelands, Bart

    2018-04-01

    Mental fatigue is a psychobiological state caused by prolonged periods of demanding cognitive activity that has negative implications on many aspects in daily life. Caffeine and carbohydrate ingestion have been shown to be able to reduce these negative effects of mental fatigue. Intake of these substances might however be less desirable in some situations (e.g., restricted caloric intake, Ramadan). Rinsing caffeine or glucose within the mouth has already been shown to improve exercise performance. Therefore, we sought to evaluate the effect of frequent caffeine-maltodextrin (CAF-MALT) mouth rinsing on mental fatigue induced by a prolonged cognitive task. Ten males (age 23 ± 2 years, physical activity 7.3 ± 4.3 h/week, low CAF users) performed two trials. Participants first completed a Flanker task (3 min), then performed a 90-min mentally fatiguing task (Stroop task), followed by another Flanker task. Before the start and after each 12.5% of the Stroop task (eight blocks), subjects received a CAF-MALT mouth rinse (MR: 0.3 g/25 ml CAF: 1.6g/25 ml MALT) or placebo (PLAC: 25 ml artificial saliva). Self-reported mental fatigue was lower in MR (p = 0.017) compared to PLAC. Normalized accuracy (accuracy first block = 100%) was higher in the last block of the Stroop in MR (p = 0.032) compared to PLAC. P2 amplitude in the dorsolateral prefrontal cortex (DLPFC) decreased over time only in PLAC (p = 0.017). Frequent mouth rinsing during a prolonged and demanding cognitive task reduces mental fatigue compared to mouth rinsing with artificial saliva.

  17. Higher Magnification Imaging of the Polished Aluminum Collector Returned from the Genesis Mission

    NASA Technical Reports Server (NTRS)

    Rodriquez, Melissa C.; Burkett, P. J.; Allton, J. H.

    2011-01-01

    The polished aluminum collector (previously referred to as the polished aluminum kidney) was intended for noble gas analysis for the Gene-sis mission. The aluminum collector, fabricated from alloy 6061T, was polished for flight with alumina, then diamond paste. Final cleaning was performed by soak-ing and rinsing with hexane, then isopropanol, and last-ly megasonically energized ultrapure water prior to installation. It was mounted inside the collector canister on the thermal shield at JSC in 2000. The polished aluminum collector was not surveyed microscopically prior to flight.

  18. Synthesis and photoluminescence of ultra-pure germanium nanoparticles

    NASA Astrophysics Data System (ADS)

    Chivas, R.; Yerci, S.; Li, R.; Dal Negro, L.; Morse, T. F.

    2011-09-01

    We have used aerosol deposition to synthesize defect and micro-strain free, ultra-pure germanium nanoparticles. Transmission electron microscopy images show a core-shell configuration with highly crystalline core material. Powder X-ray diffraction measurements verify the presence of highly pure, nano-scale germanium with average crystallite size of 30 nm and micro-strain of 0.058%. X-ray photoelectron spectroscopy demonstrates that GeO x ( x ⩽ 2) shells cover the surfaces of the nanoparticles. Under optical excitation, these nanoparticles exhibit two separate emission bands at room temperature: a visible emission at 500 nm with 0.5-1 ns decay times and an intense near-infrared emission at 1575 nm with up to ˜20 μs lifetime.

  19. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J; Liikala, Terry L; Strenge, Dennis L

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for ''No Further Action'' by previous investigators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  20. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Liikala, Terry L.; Strenge, Dennis L.

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for "No Further Action" by previous invesitgators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  1. Running Performance With Nutritive and Nonnutritive Sweetened Mouth Rinses.

    PubMed

    Hawkins, Keely R; Krishnan, Sridevi; Ringos, Lara; Garcia, Vanessa; Cooper, Jamie A

    2017-09-01

    Using mouth rinse (MR) with carbohydrate during exercise has been shown to act as an ergogenic aid. To investigate if nutritive or nonnutritive sweetened MR affects exercise performance and to assess the influence of sweetness intensity on endurance performance during a time trial (TT). This randomized, single-blinded study had 4 treatment conditions. Sixteen subjects (9 men, 7 women) completed a 12.8-km TT 4 different times. During each TT, subjects mouth-rinsed and expectorated a different solution at time 0 and every 12.5% of the TT. The 4 MR solutions were sucrose (S) (sweet taste and provides energy of 4 kcal/g), a lower-intensity sucralose (S1:1) (artificial sweetener that provides no energy but tastes sweet), a higher-intensity sucralose (S100:1), and water as control (C). Completion times for each TT, heart rate (HR), and ratings of perceived exertion (RPE) were also recorded. Completion time for S was faster than for C (1:03:47 ± 00:02:17 vs 1:06:56 ± 00:02:18, respectively; P < .001) and showed a trend to be faster vs S100:1 (1:03:47 ± 00:02:17 vs 1:05:38 ± 00:02:12, respectively; P = .07). No other TT differences were found. Average HR showed a trend to be higher for S vs C (P = .08). The only difference in average or maximum RPE was for higher maximum RPE in C vs S1:1 (P = .02). A sweet-tasting MR did improve endurance performance compared with water in a significant manner (mean 4.5% improvement; 3+ min.); however, the presence of energy in the sweet MR appeared necessary since the artificial sweeteners did not improve performance more than water alone.

  2. γ-Aminobutyric acid (GABA) oral rinse reduces capsaicin-induced burning mouth pain sensation: An experimental quantitative sensory testing study in healthy subjects.

    PubMed

    Zhang, Y; Wang, K; Arendt-Nielsen, L; Cairns, B E

    2018-02-01

    In burning mouth patients, analgesia after oral administration of clonazepam may result from modulation of peripheral γ-aminobutyric acid (GABA) receptors. The effect of oral administration of test solutions (water, 0.5 mol/L or 0.05 mol/L GABA, 1% lidocaine) was investigated for the amelioration of pain and sensitivity induced by application of capsaicin (1%, 2 min) to the tongue of thirty healthy male and female subjects in this four-session, randomized, placebo-controlled, double-blinded, cross-over study. Intra-oral quantitative sensory testing was used to assess cold (CDT), warm (WDT) and mechanical (MDT) detection thresholds as well as mechanical (MPT) and heat (HPT) pain thresholds. Capsaicin-induced pain intensity was continuously rated on a 0-10 electronic visual analogue scale (VAS). The area under the VAS curve (VASAUC) after rinsing was calculated for each solution. Capsaicin application on the tongue evoked burning pain with a peak of 4.8/10, and significantly increased CDT and MDT while significantly decreasing WDT, HPT, and MPT. The VASAUC was significantly smaller after oral rinse with 0.05 mol/L GABA, 0.5 mol/L GABA, and 1% lidocaine than after oral rinse with water. Rinse with 0.5 mol/L or 0.05 mol/L GABA were similarly effective in decreasing VASAUC. Rinsing with either 1% lidocaine, 0.5 mol/L or 0.05 mol/L GABA also significantly attenuated the effects of capsaicin on WDT and HPT in a treatment independent manner. There were no sex-related differences in these effects of GABA. Capsaicin-induced burning tongue pain and decreases in WDT and HPT can be ameliorated by rinsing the mouth with lidocaine and GABA solutions. Rinsing the mouth with an oral GABA containing solution ameliorated burning pain and increased heat sensitivity produced by application of capsaicin to the tongue. This finding suggests that GABA can act as a local analgesic agent in the oral cavity. © 2017 European Pain Federation - EFIC®.

  3. Photolysis of model emerging contaminants in ultra-pure water: kinetics, by-products formation and degradation pathways.

    PubMed

    Benitez, F Javier; Acero, Juan L; Real, Francisco J; Roldan, Gloria; Rodriguez, Elena

    2013-02-01

    The photolysis of five frequent emerging contaminants (Benzotriazole, Chlorophene, N,N-diethyl-m-toluamide or DEET, Methylindole, and Nortriptyline HCl) was investigated in ultrapure water under monochromatic ultraviolet radiation at 254 nm and by a combination of UV and hydrogen peroxide. The results revealed that the photolysis rates followed first-order kinetics, with rate constant values depending on the nature of the specific compound, the pH, and the presence or absence of the scavenger tert-butanol. Quantum yields were also determined and values in the range of 53.8 × 10⁻³ - 9.4 × 10⁻³ mol E⁻¹ for Benzotriazole, 525 × 10⁻³ - 469 × 10⁻³ mol E⁻¹ for Chlorophene, 2.8 × 10⁻³ - 0.9 × 10⁻³ mol E⁻¹ for DEET, 108 × 10⁻³ - 165 × 10⁻³ mol E⁻¹ for Methylindole, and 13.8 × 10⁻³ - 15.0 × 10⁻³ mol E⁻¹ for Nortriptyline were obtained. The study also found that the UV/H₂O₂ process enhanced the oxidation rate in comparison to direct photolysis. High-performance liquid chromatography coupled to electrospray ionization quadrupole time-of-flight mass spectrometry (HPLC-ESI-QTOF-MS) technique was applied to the concentrations evaluation and further identification of the parent compounds and their by-products, which allowed the proposal of the degradation pathways for each compound. Finally, in order to assess the aquatic toxicity in the photodegradation of these compounds, the Vibrio fischeri acute toxicity test was used, and the results indicated an initial increase of this parameter in all cases, followed by a decrease in the specific case of Benzotriazole, DEET, Methylindole, and Chlorophene. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  5. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  6. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  7. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  8. 21 CFR 872.5580 - Oral rinse to reduce the adhesion of dental plaque.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oral rinse to reduce the adhesion of dental plaque... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5580 Oral rinse to reduce the adhesion of dental plaque. (a) Identification. The device is assigned the generic name oral rinse to reduce...

  9. Low temperature processing of ultra-pure cellulose fibers into nylon 6 and other thermoplastics

    Treesearch

    Rod Jacobson; Dan Caulfield; Karl Sears; John Underwood

    2002-01-01

    The objective of this research was to develop a stable process for compound ultra-pure cellulose fibers into polyamides. This has been a difficult procedure and has taken years of trial and error to understand the viscosity shear heating effects associated with compounding cellulose into high-melting point engineering thermoplastics. The evolution of the low...

  10. Comparison between Rinse and Crush-and-Rub Sampling for Aerobic Bacteria Recovery from Hatching Eggs after Sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatments with sanitizers. Eggs were arranged into 5 treatments consisting of three sanitizers, Water, and No-treatment. Sanitizers were Hydrogen...

  11. Polyethylene glycol rinse solution: An effective way to prevent ischemia-reperfusion injury

    PubMed Central

    Zaouali, Mohamed Amine; Bejaoui, Mohamed; Calvo, Maria; Folch-Puy, Emma; Pantazi, Eirini; Pasut, Gianfranco; Rimola, Antoni; Ben Abdennebi, Hassen; Adam, René; Roselló-Catafau, Joan

    2014-01-01

    AIM: To test whether a new rinse solution containing polyethylene glycol 35 (PEG-35) could prevent ischemia-reperfusion injury (IRI) in liver grafts. METHODS: Sprague-Dawley rat livers were stored in University of Wisconsin preservation solution and then washed with different rinse solutions (Ringer’s lactate solution and a new rinse solution enriched with PEG-35 at either 1 or 5 g/L) before ex vivo perfusion with Krebs-Heinseleit buffer solution. We assessed the following: liver injury (transaminase levels), mitochondrial damage (glutamate dehydrogenase activity), liver function (bile output and vascular resistance), oxidative stress (malondialdehyde), nitric oxide, liver autophagy (Beclin-1 and LCB3) and cytoskeleton integrity (filament and globular actin fraction); as well as levels of metalloproteinases (MMP2 and MMP9), adenosine monophosphate-activated protein kinase (AMPK), heat shock protein 70 (HSP70) and heme oxygenase 1 (HO-1). RESULTS: When we used the PEG-35 rinse solution, reduced hepatic injury and improved liver function were noted after reperfusion. The PEG-35 rinse solution prevented oxidative stress, mitochondrial damage, and liver autophagy. Further, it increased the expression of cytoprotective heat shock proteins such as HO-1 and HSP70, activated AMPK, and contributed to the restoration of cytoskeleton integrity after IRI. CONCLUSION: Using the rinse solution containing PEG-35 was effective for decreasing liver graft vulnerability to IRI. PMID:25473175

  12. Timer Rinse Control Systems.

    DTIC Science & Technology

    1985-09-01

    Amonium Nitrate 301 Alkaline rust 104 Cold rinse remover 105...LABORATORY IAFESC/RDVW I IDTIC SLECTE DECO 3 WE SEPTEMBER 1985 D FINAL REPORT JANUARY 1985 -JUNE 1985 J APPROVED FOR PUBLIC RELEASE: DISTRIBUTION UNLIMITED...VIRGINIA 22314 .4" -5 . • " - ’ -. "." . . ."" L. . " -’ ’- ", "" -" " ". . . * V . . .," S " , ." ,. a V ’ *" " UNCLASSIFIEDA D ScURITY

  13. In vitro study of the effect of an essential oil and a delmopinol mouth rinse on dental plaque bacteria.

    PubMed

    LuIs, Henrique Soares; Luis, Luis Soares; Bernardo, Mário

    2016-01-01

    Mouthrinses are used, by many of our patients, as a complement to daily dental hygiene routine. The use of a toothbrush and an interproximal cleaning method may not be enough to control dental plaque. Essential oils and delmopinol mouth rinses are effective for the prevention of dental caries and gingivitis. To study the effect of an essential oil and a delmopinol mouth rinse on dental plaque bacteria, an in vitro study was developed. The objective of this study was to determine the antibacterial activity of an essential oil and a delmopinol mouth rinse on Streptococcus mutans, Lactobacilli, and aerobic and anaerobic dental plaque nonspecific bacteria. Samples of human dental plaque were collected from consenting participants and bacteria isolated. Disk-diffusion tests were performed to obtain the minimum concentration of the mouth rinses necessary to inhibit bacterial growth. The ability of the commercial mouth rinses to inhibit bacterial growth was studied in comparison to a positive control (0.2% chlorhexidine) and a negative laboratorial control (sterilized water). The minimum inhibitory concentration was found to be inferior to the commercial essential oils and delmopinol mouth rinses concentrations. Delmopinol and essential oils have significant antibacterial properties shown in vitro only for aerobic bacteria, and for S. mutans, Lactobacillus, and anaerobic bacteria, the results were not statistically significant. Essential oils and chlorhexidine are statistically similar and better than delmopinol for aerobic bacteria growth inhibition. For the other bacteria, essential oils and delmopinol are not statistically promising. Results show that essential oils only may help patients to maintain good oral health as a complement to daily brushing and interproximal cleaning.

  14. Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year.

    PubMed

    Porteous, N; Dang, S; Schoolfield, J; Sun, Y

    2016-03-01

    The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student's t-tests. An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used.

  15. Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year

    PubMed Central

    Porteous, N.; Dang, S.; Schoolfield, J.; Sun, Y.

    2017-01-01

    Objective The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). Methods A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student’s t-tests. Results An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. Conclusions No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used. PMID:28390212

  16. Effect of various rinsing protocols after use of amine fluoride/stannous fluoride toothpaste on the bacterial composition of dental plaque.

    PubMed

    van Loveren, C; Gerardu, V A M; Sissons, C H; van Bekkum, M; ten Cate, J M

    2009-01-01

    This clinical study evaluated the effect of different oral hygiene protocols on the bacterial composition of dental plaque. After a 2-week period of using fluoride-free toothpaste, 30 participants followed three 1-week experimental protocols, each followed by 2-week fluoride-free washout periods in a randomized crossover examiner-blind controlled trial. The 1-week experimental protocols comprised the use of AmF/SnF(2) toothpaste twice daily, after which participants either (1) rinsed with tap water, (2) did not rinse but only spat out the toothpaste, or (3) rinsed with an AmF/SnF(2) mouthwash. In the fluoride-free washout periods, the participants brushed their teeth with fluoride-free toothpaste without further instructions. Six hours after the last brushing (+/- rinsing) of each period, buccal plaque samples in the upper molar region were taken. The microbiota composition of the plaque samples was analyzed by checkerboard DNA:DNA hybridization. A statistically significant reduction was found in the total amount of DNA of the 39 major plaque species measured, and in the proportions of some acid-producing bacterial strains after the period having used the AmF/SnF(2) toothpaste + AmF/SnF(2) mouthrinsing. The results indicate that using the AmF/SnF(2) toothpaste and rinse combination could result in plaque of lower cariogenicity. Copyright 2009 S. Karger AG, Basel.

  17. Cavity Preparation/assembly Techniques and Impact on Q, Realistic Q - Factors in a Module, Review of Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter Kneisel

    2005-03-19

    This contribution summarizes the surface preparation procedures for niobium cavities presently used both in laboratory experiments and for modules, such as buffered chemical polishing (BCP), electropolishing (EP), high pressure ultrapure water rinsing (HPR), CO{sub 2} snow cleaning and high temperature heat treatments for hydrogen degassing or postpurification. The impact of surface treatments and the degree of cleanliness during assembly procedures on cavity performance (Q - value and accelerating gradient E{sub acc}) will be discussed. In addition, an attempt will be made to summarize the experiences made in module assemblies in different labs/projects such as DESY(TTF), Jlab (Upgrade) and SNS.

  18. Detection of HPV related oropharyngeal cancer in oral rinse specimens

    PubMed Central

    Rosenthal, Matthew; Huang, Bin; Katabi, Nora; Migliacci, Jocelyn; Bryant, Robert; Kaplan, Samuel; Blackwell, Timothy; Patel, Snehal; Yang, Liying; Pei, Zhiheng; Tang, Yi-Wei; Ganly, Ian

    2017-01-01

    Background The majority of patients diagnosed with oropharyngeal squamous cell cancer (OPSCC) are due to HPV infection. At present, there are no reliable tests for screening HPV in patients with OPSCC. The objective of this study was to assess the Cobas® HPV Test on oral rinse specimens as an early, non-invasive tool for HPV-related OPSCC. Methods Oral rinse specimens were collected from 187 patients (45 with OPSCC, 61 with oral cavity SCC (OCSCC) and 81 control patients who had benign or malignant thyroid nodules) treated at MSKCC. The Cobas® HPV Test was used to detect 14 high-risk HPV types in these samples. Performance of the HPV Test was correlated with p16 tumor immunohistochemistry as gold standard. Results 91.1% of the oropharynx cancer patients had p16 positive tumors compared to 3.3% of oral cavity cancer. Of the 81 control patients, 79 (97.5%) had no HPV in their oral rinse giving a specificity of the HPV test of 98%. For the combined oral cavity oropharynx cancer cohort, the sensitivity, specificity, positive predictive value and negative predictive value of the HPV Test were 79.1%, 90.5%, 85.0% and 86.4% respectively when p16 immunohistochemistry was used as the reference. Conclusion The Cobas® HPV Test on oral rinse is a highly specific and potentially sensitive test for oropharyngeal cancer and may be a potentially useful screening test for early oropharyngeal cancer. Impact We describe an oral rinse test for the detection of HPV related oropharyngeal cancer. PMID:29312616

  19. Comparison between rinse and crush-and-rub sampling for aerobic bacteria recovery from broiler hatching eggs after sanitization

    USDA-ARS?s Scientific Manuscript database

    This study compared surface and deep eggshell aerobic bacteria recovered by rinse and crush-and-rub sampling methods for commercial hatching eggs after treatment with sanitizers. Eggs were arranged into 5 treatments consisting of No-treatment, Water, and three sanitizers. Sanitizers were Hydrogen ...

  20. The Influence of Serial Carbohydrate Mouth Rinsing on Power Output during a Cycle Sprint.

    PubMed

    Phillips, Shaun M; Findlay, Scott; Kavaliauskas, Mykolas; Grant, Marie Clare

    2014-05-01

    The objective of the study was to investigate the influence of serial administration of a carbohydrate (CHO) mouth rinse on performance, metabolic and perceptual responses during a cycle sprint. Twelve physically active males (mean (± SD) age: 23.1 (3.0) years, height: 1.83 (0.07) m, body mass (BM): 86.3 (13.5) kg) completed the following mouth rinse trials in a randomized, counterbalanced, double-blind fashion; 1. 8 x 5 second rinses with a 25 ml CHO (6% w/v maltodextrin) solution, 2. 8 x 5 second rinses with a 25 ml placebo (PLA) solution. Following mouth rinse administration, participants completed a 30 second sprint on a cycle ergometer against a 0.075 g·kg(-1) BM resistance. Eight participants achieved a greater peak power output (PPO) in the CHO trial, resulting in a significantly greater PPO compared with PLA (13.51 ± 2.19 vs. 13.20 ± 2.14 W·kg(-1), p < 0.05). Magnitude inference analysis reported a likely benefit (81% likelihood) of the CHO mouth rinse on PPO. In the CHO trial, mean power output (MPO) showed a trend for being greater in the first 5 seconds of the sprint and lower for the remainder of the sprint compared with the PLA trial (p > 0.05). No significant between-trials difference was reported for fatigue index, perceived exertion, arousal and nausea levels, or blood lactate and glucose concentrations. Serial administration of a CHO mouth rinse may significantly improve PPO during a cycle sprint. This improvement appears confined to the first 5 seconds of the sprint, and may come at a greater relative cost for the remainder of the sprint. Key pointsThe paper demonstrates that repeated administration of a carbohydrate mouth rinse can significantly improve peak power output during a single 30 second cycle sprint.The ergogenic effect of the carbohydrate mouth rinse may relate to the duration of exposure of the oral cavity to the mouth rinse, and associated greater stimulation of oral carbohydrate receptors.The significant increase in peak power

  1. Effect of Minocycline on the Durability of Dentin Bonding Produced with Etch-and-Rinse Adhesives.

    PubMed

    Loguercio, A D; Stanislawczuk, R; Malaquias, P; Gutierrez, M F; Bauer, J; Reis, A

    2016-01-01

    To evaluate the effect of minocycline and chlorhexidine pretreatment of acid-etched dentin on the longevity of resin-dentin bond strength (μTBS) and nanoleakage of two-step etch-and-rinse adhesives. Before application of Prime & Bond NT and Adper Single Bond 2 in occlusal dentin, the dentin surfaces were treated with 37% phosphoric acid, rinsed, air-dried, and rewetted with water (control group), 2% minocycline, or 2% chlorexidine digluconate. Composite buildups were constructed incrementally, and specimens were longitudinally sectioned to obtain bonded sticks (0.8 mm 2 ) to be tested in tension (0.5 mm/min) immediately or after 24 months of water storage. For nanoleakage, two specimens of each tooth/period were immersed in the silver nitrate solution, photo-developed, and polished with SiC paper for analysis under energy-dispersive X-ray spectroscopy/scanning electron microscopy. Reductions of the μTBS and increases in the nanoleakage were observed for both adhesives when the rewetting procedure was performed with water. Stable bonds were observed for the 2% minocycline and 2% chlorexidine digluconate groups after 24 months. The use of 2% minocycline as pretreatment of acid-etched dentin is one alternative to retard the degradation of resin-dentin interfaces over a 24-month period as well as 2% chlorexidine digluconate.

  2. Ultrapure glass optical waveguide development in microgravity by the sol-gel process

    NASA Technical Reports Server (NTRS)

    Mukherjee, S. P.

    1980-01-01

    The alkali-borosilicate system was selected as the glass system for the preparation of ultrapure low loss glasses suitable for optical communication. The effect of different oxide contents on the absorption loss was critically reviewed. One composition was chosen to develop the gel preparation procedure in the alkali-borosilicate system. In addition, several procedures for the preparation of gels based on two different approaches were developed. The influence of different preparation parameters were investigated qualitatively. Several conclusions are drawn from the results.

  3. Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse

    DTIC Science & Technology

    2010-09-01

    400 and 300 h in neutral salt spray. 5 Similarly plated samples post treated with trivalent chromium rinse lasted 450 and 200 h in neutral salt...Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse by Chris E. Miller, Brian E...Posttreated With Trivalent Chromate Rinse Chris E. Miller and Brian E. Placzankis Weapons and Materials Research Directorate, ARL I. Carl Handsy

  4. Bond strength of resin-modified glass ionomer restorative materials using a no-rinse conditioner.

    PubMed

    Suihkonen, Rian W; Vandewalle, Kraig S; Dossett, Jon M

    2012-01-01

    A paste-paste resin-modified glass ionomer (RMGI) restorative material has been introduced recently with a new conditioner that requires no rinsing. The purpose of this study was to compare the shear bond strength of an encapsulated RMGI (Fuji II LC) and a new paste-paste RMGI (Fuji Filling LC) to dentin conditioned with 20% polyacrylic acid (Cavity Conditioner), a new no-rinse conditioner (Self Conditioner,), or no conditioner. Mounted human third molars were flattened and the dentin surface was conditioned. The RMGI restorative materials were mixed and incrementally inserted into a mold and photocured. The specimens were loaded until failure in a universal testing machine after 24 hours of storage in distilled water. Fuji II LC had significantly greater bond strength to dentin than Fuji Filling LC. The use of Cavity Conditioner or Self Conditioner resulted in bond strengths that were not significantly different from each other; however, both produced greater bond strengths than those in the non-conditioned groups.

  5. Comparison of wiping and rinsing techniques after oral care procedures in critically ill patients during endotracheal intubation and after extubation: A prospective cross-over trial.

    PubMed

    Muramatsu, Keita; Matsuo, Koichiro; Kawai, Yusuke; Yamamoto, Tsukasa; Hara, Yoshitaka; Shimomura, Yasuyo; Yamashita, Chizuru; Nishida, Osamu

    2018-06-26

    Endotracheal intubation of critically ill patients increases the risk of aspiration pneumonia, which can be reduced by regular oral care. However, the rinsing of the residual oral contaminants after mechanical cleaning carries the risk of aspirating the residue during the intubation period. Removing the contaminants by wiping with mouth wipes could be an alternative to rinsing with water because of no additional fluid. This study tested: (i) the amount of oral bacteria during endotracheal intubation and after extubation; and (ii) the changes in the bacterial count during oral care procedures. Thirty-five mechanically ventilated patients in the intensive care unit were enrolled. The amount of bacteria on the dorsal tongue surface was counted before and following oral care and then after the elimination of contaminants either by rinsing with water and suctioning or by wiping with mouth wipes. The oral bacterial amount was compared statistically between the intubation and extubation status and among set time points during the oral care procedure. The oral bacterial count was significantly decreased after extubation. During the oral care procedure, the oral bacterial amount was significantly lower after eliminating the contaminants either by rinsing or wiping, with no remarkable difference between the elimination techniques. The findings suggest that the oral bacterial amount is elevated during endotracheal intubation, which could increase the risk of aspiration pneumonia. The significant reduction in the bacterial count by wiping indicates that it might be a suitable alternative to rinsing for mechanically ventilated patients. © 2018 Japan Academy of Nursing Science.

  6. Effects of prolonged light exposure times on water sorption, solubility and cross-linking density of simplified etch-and-rinse adhesives.

    PubMed

    Wambier, Letícia; Malaquias, Tamirez; Wambier, Denise Stadler; Patzlaff, Rafael T; Bauer, José; Loguercio, Alessandro D; Reis, Alessandra

    2014-06-01

    This study evaluated the effects of light exposure times on water sorption, solubility, and polymer cross-linking density of simplified etch-and-rinse adhesives. Four commercial adhesives (XP Bond, Adper Single Bond 2, Tetric N-Bond, and Ambar) were selected, and resin disks 5 mm in diameter and 1.0 mm thick were prepared and light cured for 20, 40, or 80 s using an LED light-curing unit at 1200 mW/cm2. Water sorption and solubility were evaluated over a 28-day period. For polymer cross-linking density, additional specimens were prepared and their Knoop hardness measured before and after immersion in 100% ethanol. The data from each test were evaluated using a two-way ANOVA and Tukey's test (α = 0.05). The XP Bond adhesive showed higher water sorption (similar to Adper Single Bond 2) and solubility (p < 0.05) than did the other materials. Prolonged exposure times did not reduce the water sorption but did reduce the solubility of all tested materials (p < 0.05). For Ambar, the increase in the exposure time resulted in a significantly lower percent reduction in hardness. Water sorption, solubility, and cross-linking density of the materials selected in this study seem to be mainly influenced by the adhesive composition. Prolonged light exposure times reduced the solubility of the materials.

  7. IMPACT OF A RINSE STEP ON PROTEIN REMOVAL FROM SILICONE HYDROGEL CONTACT LENSES

    PubMed Central

    Pucker, Andrew D.; Nichols, Jason J.

    2010-01-01

    PURPOSE To determine the impact of the rinse step in “no rub” contact lens care systems relative to its ability to assist in removing loosely associated and bound tear film proteins from a worn silicone hydrogel lens. METHODS After informed consent, subjects were fitted with lotrafilcon B contact lenses (CIBA Vision, Inc). If the fit was acceptable, subjects were asked to wear the lenses on a daily wear basis for 5 (+2, −0) days for an outcome visit. Subjects were instructed to use AQuify Multi-Purpose Disinfecting Solution (CIBA Vision, Inc) following the manufacturer's “no rub” instructions. At the outcome visit, contact lenses were then collected by a gloved examiner, with a sterile metal forceps, who rinsed the right lens but did not rinse the left lens upon removal from the eyes. Protein was extracted with a 50:50 0.2% trifluoroacetic acid-acetonitrile solution and quantified using a Bradford analyses. RESULTS Twenty contact lens wearers were enrolled in this study. For the non-rinsed lenses, the first extraction yielded 13.4 ± 9.2 µg/lens of protein, while the second extraction yielded 5.8 ± 2.8 µg/lens of protein. For the rinsed lenses, first extraction yielded an average of 3.0 ± 1.9 µg/lens of protein, while the second extraction yielded an average of 4.0 ± 2.3 µg/lens. Repeated measures ANOVA showed a significant interaction (F-statistic = 18.9, p< 0.0001) between the rinse of a lens and extraction number. CONCLUSIONS Rinsing a contact lens following removal from the eye removes well over one-half of the protein associated with it. Further, in order to biochemically recover all protein from a silicone hydrogel lens, it may be important to perform more than one chemical extraction from it. PMID:19609231

  8. Efficacy of mouth rinses and toothpaste on tooth whitening.

    PubMed

    Torres, C R G; Perote, L C C C; Gutierrez, N C; Pucci, C R; Borges, A B

    2013-01-01

    People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel. We obtained 120 cylindrical specimens from bovine teeth, which were darkened for 24 hours in a coffee solution. The color measurement was performed by a spectrophotometer using the CIE L*a*b* system, and specimens were divided into six groups according to the use of the following agents: group 1, conventional fluoridated toothpaste; group 2, Close Up White Now; group 3, Listerine Whitening; group 4, Colgate Plax Whitening; group 5, experimental mouth rinse with Plasdone; and group 6, 10% CP Whiteness Perfect. After the simulation of 12 weeks of treatment for groups 1 to 5 and 14 days of treatment for group 6, the specimens were subjected to a new color reading. Data were subjected to one-way analysis of variance (α=0.05), which showed significant differences among groups after 12 weeks for ΔE (p=0.001). Results of the Tukey test revealed that groups 3, 4, and 6 presented significantly higher color alteration than groups 1, 2, and 5. The whitening toothpaste Close Up White Now and the experimental mouth rinse with Plasdone showed similar color alteration as conventional toothpaste after a 12-week treatment simulation. These groups presented significantly lower color alteration compared with whitening mouth rinses Listerine and Colgate Plax Whitening, which showed similar results to those observed after 14 days of bleaching with 10% CP treatment.

  9. A Rinsing Effluent Evaporator for Dismantling Operations - 13271

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rives, Rachel; Asou-Pothet, Marielle; Chambon, Frederic

    2013-07-01

    Between 1958 and 1997, the UP1 plant at Marcoule - located in the south of France - reprocessed and recycled nearly 20,000 MT of used fuel from special defense applications reactors, as well as fuel from the first generation of electricity generating reactors in France (natural uranium fuel, CO{sub 2}-cooled, graphite-moderated). Decommissioning and Dismantling of the UP1 plant and its associated units started in 1998. Since 2005, the UP1 facility has been operated by AREVA as the Marcoule Management and Operation contractor for French Atomic Energy Commission (CEA). An important part of this decommissioning program deals with the vitrification facilitymore » of Marcoule. This facility includes 20 tanks devoted to interim storage of highly active solutions, prior to vitrification. In 2006, a rinsing program was defined as part of the tank cleanup strategy. The main objective of the rinsing phases was to decrease activity in order to limit the volume of 'long-life active' waste produced during the decommissioning operations, so the tanks can be dismantled without the need of remote operations. To enable this rinsing program, and anticipating large volumes of generated effluent, the construction of an evaporation unit proved to be essential. The main objective of this unit was to concentrate the effluent produced during tank rinsing operations by a factor of approximately 10, prior to it being treated by vitrification. The evaporator design phase was launched in September 2006. The main challenge for the Project team was the installation of this new unit within a nuclear facility still in operation and in existing compartments not initially designed for this purpose. Cold operating tests were completed in 2008, and in May 2009, the final connections to the process were activated to start the hot test phase. During the first hot test operations performed on the first batches of clean-up effluent, the evaporator had a major operating problem. Extremely large

  10. Effects of chlorhexidine preprocedural rinse on bacteremia in periodontal patients: a randomized clinical trial

    PubMed Central

    Balejo, Rodrigo Dalla Pria; Cortelli, José Roberto; Costa, Fernando Oliveira; Cyrino, Renata Magalhães; Aquino, Davi Romeiro; Cogo-Müller, Karina; Miranda, Taís Browne; Moura, Sara Porto; Cortelli, Sheila Cavalca

    2017-01-01

    Abstract Objective: Single dose of systemic antibiotics and short-term use of mouthwashes reduce bacteremia. However, the effects of a single dose of preprocedural rinse are still controversial. This study evaluated, in periodontally diseased patients, the effects of a pre-procedural mouth rinse on induced bacteremia. Material and Methods: Systemically healthy individuals with gingivitis (n=27) or periodontitis (n = 27) were randomly allocated through a sealed envelope system to: 0.12% chlorhexidine pre-procedural rinse (13 gingivitis and 13 periodontitis patients) or no rinse before dental scaling (14 gingivitis and 15 periodontitis patients). Periodontal probing depth, clinical attachment level, plaque, and gingival indices were measured and subgingival samples were collected. Blood samples were collected before dental scaling, 2 and 6 minutes after scaling. Total bacterial load and levels of P. gingivalis were determined in oral and blood samples by real-time polymerase chain reaction, while aerobic and anaerobic counts were determined by culture in blood samples. The primary outcome was the antimicrobial effect of the pre-procedural rinse. Data was compared by Mann-Whitney and Signal tests (p<0.05). Results: In all sampling times, polymerase chain reaction revealed higher blood bacterial levels than culture (p<0.0001), while gingivitis patients presented lower bacterial levels in blood than periodontitis patients (p<0.0001). Individuals who experienced bacteremia showed worse mean clinical attachment level (3.4 mm vs. 1.1 mm) and more subgingival bacteria (p<0.005). The pre-procedural rinse did not reduce induced bacteremia. Conclusions: Bacteremia was influenced by periodontal parameters. In periodontally diseased patients, pre-procedural rinsing showed a discrete effect on bacteremia control. PMID:29211279

  11. The Influence of Carbohydrate Mouth Rinse on Self-Selected Intermittent Running Performance.

    PubMed

    Rollo, Ian; Homewood, George; Williams, Clyde; Carter, James; Goosey-Tolfrey, Vicky L

    2015-12-01

    This study investigated the influence of mouth rinsing a carbohydrate solution on self-selected intermittent variable-speed running performance. Eleven male amateur soccer players completed a modified version of the Loughborough Intermittent Shuttle Test (LIST) on 2 occasions separated by 1 wk. The modified LIST allowed the self-selection of running speeds during Block 6 of the protocol (75-90 min). Players rinsed and expectorated 25 ml of noncaloric placebo (PLA) or 10% maltodextrin solution (CHO) for 10 s, routinely during Block 6 of the LIST. Self-selected speeds during the walk and cruise phases of the LIST were similar between trials. Jogging speed was significantly faster during the CHO (11.3 ± 0.7 km · h(-1)) than during the PLA trial (10.5 ± 1.3 km · h(-1)) (p = .010); 15-m sprint speeds were not different between trials (PLA: 2.69 ± 0.18 s: CHO: 2.65 ± 0.13 s) (F(2, 10), p = .157), but significant benefits were observed for sprint distance covered (p = .024). The threshold for the smallest worthwhile change in sprint performance was set at 0.2 s. Inferential statistical analysis showed the chance that CHO mouth rinse was beneficial, negligible, or detrimental to repeated sprint performance was 86%, 10%, and 4%, respectively. In conclusion, mouth rinsing and expectorating a 10% maltodextrin solution was associated with a significant increase in self-selected jogging speed. Repeated 15-m sprint performance was also 86% likely to benefit from routinely mouth rinsing a carbohydrate solution in comparison with a taste-matched placebo.

  12. Evaluation of potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar for enumeration of Campylobacter in chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-05-01

    Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess. © 2014 Institute of Food Technologists®

  13. A 5 year longitudinal study of water quality for final rinsing in the single chamber washer-disinfector with a reverse osmosis plant.

    PubMed

    Uetera, Yushi; Kishii, Kozue; Yasuhara, Hiroshi; Kumada, Naohito; Moriya, Kyoji; Saito, Ryoichi; Okazaki, Mitsuhiro; Misawa, Yoshiki; Kawamura, Kunio

    2013-01-01

    This report deals with the construction and management of the reverse osmosis (RO) water system for final rinsing of surgical instruments in the washer-disinfector. Numerous operational challenges were encountered in our RO water system and these were analyzed utilizing the Ishikawa Fishbone diagram. The aim was to find potential problems and promote preventive system management for RO water. It was found that the measures that existed were inappropriate for preventing contamination in the heat-labile RO water system. The storage tank was found to be significantly contaminated and had to be replaced with a new one equipped with a sampling port and water drainage system. Additional filters and an UV treatment lamp were installed. The whole system disinfection started 1.5 years later using a peracetic acid-based compound after confirming the material compatibility. Operator errors were found when a new water engineer took over the duty from his predecessor. It was also found that there were some deficiencies in the standard operating procedures (SOPs), and that on-the-job training was not enough. The water engineer failed to disinfect the sampling port and water drainage system. The RO membrane had been used for 4 years, even though the SOP standard specified changing it as every 3 years. Various bacteria, such as Rothia mucilaginosa, were cultured from the RO water sampled from the equipment. Because Rothia mucilaginosa is a resident in the oral cavity and upper respiratory tract, it is believed that the bacteria were introduced into the system by the maintenance personnel or working environment. Therefore, the presence of R. mucilaginosa implied the failure of sanitary maintenance procedures. This study suggests that water systems should be designed based on the plans for profound system maintenance. It also suggests that SOP and on-the job training are essential to avoid any operator errors. These results must be carefully considered when either constructing new

  14. The effect of sodium bicarbonate oral rinse on salivary pH and oral microflora: A prospective cohort study.

    PubMed

    Chandel, Siddhartha; Khan, Mohsin Ali; Singh, Nishi; Agrawal, Amiya; Khare, Vinita

    2017-01-01

    Present study is designed to explore the effect of sodium bicarbonate oral rinse on salivary pH and oral micro flora. Twenty five healthy subjects were recruited for the study in department of dentistry in Era Medical College. Subjects were abstained from tooth brushing overnight pre rinse (control) samples were collected after one hour of dinner and were asked to rinse with pre calibrated freshly prepared sodium bicarbonate solution. The salivary samples were then collected the following morning using sterile gauze in marked bottles. Aerobic bacterial culture was done by plating the sample directly from the swab on the surface of Blood agar and Mac Conkeys media respectively. The colony forming units and ph were calculated for the pre rinse and post rinse saliva sample. Results shows that salivary pH increased significantly after sodium Bicarbonate oral rinse. There was a marginal decrease in number of CFU/ml for bacteria especially Viridans Streptococci, Moraxella species. Sodium Bicarbonate oral rinse may be considered as a cheap and effective alternative for chlorhexidine and alcohol based mouth wash, especially where long duration usage is required.

  15. Mouth rinsing with a carbohydrate solution attenuates exercise-induced decline in executive function.

    PubMed

    Konishi, Kana; Kimura, Tetsuya; Yuhaku, Atsushi; Kurihara, Toshiyuki; Fujimoto, Masahiro; Hamaoka, Takafumi; Sanada, Kiyoshi

    2017-01-01

    A decline in executive function could have a negative influence on the control of actions in dynamic situations, such as sports activities. Mouth rinsing with a carbohydrate solution could serve as an effective treatment for preserving the executive function in exercise. The purpose of this study was to examine the effects of mouth rinsing with a carbohydrate solution on executive function after sustained moderately high-intensity exercise. Eight young healthy participants completed 65 min of running at 75% V̇O 2 max with two mouth-rinsing conditions: with a carbohydrate solution (CHO) or with water (CON). Executive function was assessed before and after exercise by using the incongruent task of the Stroop Color and Word Test. The levels of blood glucose; and plasma adrenocorticotropic hormone (ACTH), epinephrine, and norepinephrine (NE) were evaluated. A two-way repeated-measures ANOVA, with condition (CHO and CON) and time (pre-exercise and post-exercise) as factors, was used to examine the main and interaction effects on the outcome measures. The reaction time in the incongruent condition of the Stroop test significantly increased after exercise in CON (pre-exercise 529 ± 45 ms vs. post-exercise 547 ± 60 ms, P  = 0.029) but not in CHO (pre-exercise 531 ± 54 ms vs. post-exercise 522 ± 80 ms), which resulted in a significant interaction (condition × time) on the reaction time ( P  = 0.028). The increased reaction time in CON indicates a decline in the executive function, which was attenuated in CHO. Increases in plasma epinephrine and NE levels demonstrated a trend toward attenuation accompanying CHO ( P  < 0.085), which appeared to be associated with the preservation of executive function. The blood glucose concentration showed neither significant interactions nor main effects of condition. These findings indicate that mouth rinsing with a carbohydrate solution attenuated the decline in executive function induced by

  16. A novel tank for DI water reduction in MEMS manufacturing

    NASA Astrophysics Data System (ADS)

    Raccurt, O.; Tardif, F.; Kerber, L.; Lardin, T.; Vareine, T.

    2003-05-01

    A new rinsing process is proposed based on the conclusions obtained by simulations. It consists of a combination of piston flows and internal top-to-bottom recycling steps, which decreases the DI water consumption (and associated cost) for the same rinsing efficiency. This novel concept re-using the DI water in situ in the rinsing tank is demonstrated using an industrial bath recently proposed on the market.

  17. Efficient HOMO-LUMO separation by multiple resonance effect toward ultrapure blue thermally activated delayed fluorescence

    NASA Astrophysics Data System (ADS)

    Hatakeyama, Takuji; Ikuta, Toshiaki; Shiren, Kazushi; Nakajima, Kiichi; Nomura, Shintaro; Ni, Jingping

    2016-09-01

    Organic light-emitting diodes (OLEDs) play an important role in the new generation of flat-panel displays. Conventional OLEDs employing fluorescent materials together with triplet-triplet annihilation suffer from a relatively low internal quantum efficiency (IQE) of 62.5%. On the other hand, the IQE of OLEDs employing phosphorescent or thermally activated delayed fluorescence (TADF) materials can reach 100%. However, these materials exhibit very broad peaks with a full-width at half-maximum (FWHM) of 70-100 nm and cannot satisfy the color-purity requirements for displays. Therefore, the latest commercial OLED displays employ blue fluorescent materials with a relatively low IQE, and efficient blue emitters with a small FWHM are highly needed. In our manuscript, we present organic molecules that exhibit ultrapure blue fluorescence based on TADF. These molecules consist of three benzene rings connected by one boron and two nitrogen atoms, which establish a rigid polycyclic framework and significant localization of the highest occupied and lowest unoccupied molecular orbitals by a multiple resonance effect. An OLED device based on the new emitter exhibits ultrapure blue emission at 467 nm with an FWHM of 28 nm, Commission Internationale de l'Eclairage (CIE) coordinates of (0.12, 0.13), and an IQE of 100%, which represent record-setting performance for blue OLED devices.

  18. Improved Detection Technique for Solvent Rinse Cleanliness Verification

    NASA Technical Reports Server (NTRS)

    Hornung, S. D.; Beeson, H. D.

    2001-01-01

    The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.

  19. 21 CFR 355.55 - Principal display panel of all fluoride rinse drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Principal display panel of all fluoride rinse drug products. 355.55 Section 355.55 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... § 355.55 Principal display panel of all fluoride rinse drug products. In addition to the statement of...

  20. 21 CFR 355.55 - Principal display panel of all fluoride rinse drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Principal display panel of all fluoride rinse drug products. 355.55 Section 355.55 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... § 355.55 Principal display panel of all fluoride rinse drug products. In addition to the statement of...

  1. Recovery of salmonella serovar enteritidis from inoculated broiler hatching eggs using shell rinse and shell crush sampling methods

    USDA-ARS?s Scientific Manuscript database

    This study compared the recovery of Salmonella from hatching eggs using three sampling methods (eggshell rinsing, eggshell crush following a previous rinse, and eggshell crush without previous rinse). Eggshells were drop-inoculated with approximately 10, 100, or 1,000 cfu/eggshell of S. Enteritidis...

  2. Chemometric analysis of the consumption of oral rinse chlorite (ClO2-) by human salivary biomolecules.

    PubMed

    Chang, Hubert; Blackburn, John; Grootveld, Martin

    2013-12-01

    Oral rinse formulations containing chlorite anion (ClO(2)(-)) as an active agent exert a range of valuable oral healthcare activities. However, salivary biomolecules which chemically react with this oxidant can, at least in principle, serve as potentially significant barriers to these therapeutic properties in the oral environment. Therefore, in this investigation, we have explored the extent of ClO(2)(-) consumption by biomolecules which scavenge this agent in human salivary supernatants (HSSs) in vitro. HSS samples were equilibrated with oral rinse formulations containing this active agent (30 s at 35 °C in order to mimic oral rinsing episodes). Differential spectrophotometric and ion-pair reversed-phase high-performance liquid chromatographic analyses were employed to determine residual ClO(2)(-) in these admixtures. Bioanalytical data acquired revealed the rapid consumption of ClO(2)(-) by biomolecular electron donors and/or antioxidants present in HSS samples. Mean ± 95 % confidence interval (CI) consumption levels of 7.14 ± 0.69 and 5.34 ± 0.69 % of the total ClO(2)(-) available were found for oral rinse products containing 0.10 and 0.40 % (w/v) ClO(2)(-), respectively. A mixed model analysis-of-variance performed on experimental data acquired demonstrated highly-significant differences between oral rinse ClO(2)(-) contents (p < 0.0001), trial participants (p < 0.001) and sampling days-within-participants (p < 0.001), and also revealed non-additive ClO(2)(-)-scavenging responses of participants' HSSs to increases in the oral rinse content of this oxidant (p < 0.0001). A slower, second phase of the reaction process (t (1/2) = 1.7-2.8 h) involved the oxidative consumption of salivary urate. These data clearly demonstrate that for recommended 30 s oral rinsing episodes performed at physiological temperature, <10 % of the total oral rinse ClO(2)(-) available is chemically and/or reductively consumed by HSS biomolecules for both

  3. Estimating removal rates of bacteria from poultry carcasses using two whole-carcass rinse volumes

    USDA-ARS?s Scientific Manuscript database

    Rinse sampling is a common method for determining the level of microbial contamination on poultry carcasses. One of the advantages of rinse sampling, over other carcass sampling methods, is that the results can be used for both process control applications and to estimate the total microbial level o...

  4. Analysis of trace contamination of phthalate esters in ultrapure water using a modified solid-phase extraction procedure and automated thermal desorption-gas chromatography/mass spectrometry.

    PubMed

    Liu, Hsu-Chuan; Den, Walter; Chan, Shu-Fei; Kin, Kuan Tzu

    2008-04-25

    The present study was aimed to develop a procedure modified from the conventional solid-phase extraction (SPE) method for the analysis of trace concentration of phthalate esters in industrial ultrapure water (UPW). The proposed procedure allows UPW sample to be drawn through a sampling tube containing hydrophobic sorbent (Tenax TA) to concentrate the aqueous phthalate esters. The solid trap was then demoisturized by two-stage gas drying before subjecting to thermal desorption and analysis by gas chromatography-mass spectrometry. This process removes the solvent extraction procedure necessary for the conventional SPE method, and permits automation of the analytical procedure for high-volume analyses. Several important parameters, including desorption temperature and duration, packing quantity and demoisturizing procedure, were optimized in this study based on the analytical sensitivity for a standard mixture containing five different phthalate esters. The method detection limits for the five phthalate esters were between 36 ng l(-1) and 95 ng l(-1) and recovery rates between 15% and 101%. Dioctyl phthalate (DOP) was not recovered adequately because the compound was both poorly adsorbed and desorbed on and off Tenax TA sorbents. Furthermore, analyses of material leaching from poly(vinyl chloride) (PVC) tubes as well as the actual water samples showed that di-n-butyl phthalate (DBP) and di(2-ethylhexyl) phthalate (DEHP) were the common contaminants detected from PVC contaminated UPW and the actual UPW, as well as in tap water. The reduction of DEHP in the production processes of actual UPW was clearly observed, however a DEHP concentration of 0.20 microg l(-1) at the point of use was still being quantified, suggesting that the contamination of phthalate esters could present a barrier to the future cleanliness requirement of UPW. The work demonstrated that the proposed modified SPE procedure provided an effective method for rapid analysis and contamination

  5. Microtensile bond strength of etch and rinse versus self-etch adhesive systems.

    PubMed

    Hamouda, Ibrahim M; Samra, Nagia R; Badawi, Manal F

    2011-04-01

    The aim of this study was to compare the microtensile bond strength of the etch and rinse adhesive versus one-component or two-component self-etch adhesives. Twelve intact human molar teeth were cleaned and the occlusal enamel of the teeth was removed. The exposed dentin surfaces were polished and rinsed, and the adhesives were applied. A microhybride composite resin was applied to form specimens of 4 mm height and 6 mm diameter. The specimens were sectioned perpendicular to the adhesive interface to produce dentin-resin composite sticks, with an adhesive area of approximately 1.4 mm(2). The sticks were subjected to tensile loading until failure occurred. The debonded areas were examined with a scanning electron microscope to determine the site of failure. The results showed that the microtensile bond strength of the etch and rinse adhesive was higher than that of one-component or two-component self-etch adhesives. The scanning electron microscope examination of the dentin surfaces revealed adhesive and mixed modes of failure. The adhesive mode of failure occurred at the adhesive/dentin interface, while the mixed mode of failure occurred partially in the composite and partially at the adhesive/dentin interface. It was concluded that the etch and rinse adhesive had higher microtensile bond strength when compared to that of the self-etch adhesives. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Comparison of neck skin versus whole carcass rinse for incidence of Salmonella and level of E. coli recovered from broiler carcasses

    USDA-ARS?s Scientific Manuscript database

    A regulatory agency (FSIS) in the U.S. rinses individual broiler carcasses with 400 mL of 1% buffered peptone water (BPW) for Salmonella incidence detection, while the European Union (EU) uses a 25 g composited neck skin sample from three carcasses. Therefore, the objectives of the study were to ob...

  7. Influence of salt and rinsing protocol on the structure of PAH/PSS polyelectrolyte multilayers.

    PubMed

    Feldötö, Zsombor; Varga, Imre; Blomberg, Eva

    2010-11-16

    A quartz crystal microbalance (QCM) and dual polarization interferometry (DPI) have been utilized to study how the structure of poly(allylamine hydrochloride) (PAH)/poly(styrene sulfonate) (PSS) multilayers is affected by the rinsing method (i.e., the termination of polyelectrolyte adsorption). The effect of the type of counterions used in the deposition solution was also investigated, and the polyelectrolyte multilayers were formed in a 0.5 M electrolyte solution (NaCl and KBr). From the measurements, it was observed that thicker layers were obtained when using KBr in the deposition solution than when using NaCl. Three different rinsing protocols have been studied: (i) the same electrolyte solution as used during multilayer formation, (ii) pure water, and (iii) first a salt solution (0.5 M) and then pure water. When the multilayer with PAH as the outermost layer was exposed to pure water, an interesting phenomenon was discovered: a large change in the energy dissipation was measured with the QCM. This could be attributed to the swelling of the layer, and from both QCM and DPI it is obvious that only the outermost PAH layer swells (to a thickness of 25-30 nm) because of a decrease in ionic strength and hence an increase in intra- and interchain repulsion, whereas the underlying layers retain a very rigid and compact structure with a low water content. Interestingly, the outermost PAH layer seems to obtain very similar thicknesses in water independent of the electrolyte used for the multilayer buildup. Another interesting aspect was that the measured thickness with the DPI evaluated by a single-layer model did not correlate with the estimated thickness from the model calculations performed on the QCM-D data. Thus, we applied a two-layer model to evaluate the DPI data and the results were in excellent agreement with the QCM-D results. To our knowledge, this evaluation of DPI data has not been done previously.

  8. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    NASA Technical Reports Server (NTRS)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  9. Ultrapure glass optical waveguide development in microgravity by the sol-gel process

    NASA Technical Reports Server (NTRS)

    Mukherjee, S. P.; Holman, R. A.

    1981-01-01

    Multicomponent, homogeneous, noncrystalline oxide gels can be prepared by the sol-gel process and these gels are promising starting materials for melting glasses in the space environment. The sol-gel process referred to here is based on the polymerization reaction of alkoxysilane with other metal alkoxy compounds or suitable metal salts. Many of the alkoxysilanes or other metal alkoxides are liquids and thus can be purified by distillation. The use of gels offers several advantages such as high purity and lower melting times and temperatures. The sol-gel process is studied for utilization in the preparation of multicomponent ultrapure glass batches for subsequent containerless melting of the batches in space to prepare glass blanks for optical waveguides.

  10. Wave-front propagation of rinsing flows on rotating semiconductor wafers

    NASA Astrophysics Data System (ADS)

    Frostad, John M.; Ylitalo, Andy; Walls, Daniel J.; Mui, David S. L.; Fuller, Gerald G.

    2016-11-01

    The semiconductor manufacturing industry is migrating to a cleaning technology that involves dispersing cleaning solutions onto a rotating wafer, similar to spin-coating. Advantages include a more continuous overall fabrication process, lower particle level, no cross contamination from the back side of a wafer, and less usage of harsh chemicals for a lower environmental impact. Rapid rotation of the wafer during rinsing can be more effective, but centrifugal forces can pull spiral-like ribbons of liquid radially outward from the advancing wave-front where particles can build up, causing higher instances of device failure at these locations. A better understanding of the rinsing flow is essential for reducing yield losses while taking advantage of the benefits of rotation. In the present work, high-speed video and image processing are used to study the dynamics of the advancing wave-front from an impinging jet on a rotating substrate. The flow-rate and rotation-speed are varied for substrates coated with a thin layer of a second liquid that has a different surface tension than the jet liquid. The difference in surface tension of the two fluids gives rise to Marangoni stresses at the interface that have a significant impact on the rinsing process, despite the extremely short time-scales involved.

  11. Site-specific mouth rinsing can improve oral odor by altering bacterial counts. Blind crossover clinical study.

    PubMed

    Alqumber, Mohammed A; Arafa, Khaled A

    2014-11-01

    To determine whether site-specific mouth rinsing with oral disinfectants can improve oral odor beyond the traditional panoral mouth disinfection with mouth rinses by targeting specifically oral malodor implicated anaerobic bacteria. Twenty healthy fasting subjects volunteered for a blinded prospective, descriptive correlational crossover cross-section clinical trial conducted during the month of Ramadan between July and August 2013 in Albaha province in Saudi Arabia involving the application of Listerine Cool Mint mouth rinse by either the traditional panoral rinsing method, or a site-specific disinfection method targeting the subgingival and supragingival plaque and the posterior third of the tongue dorsum, while avoiding the remaining locations within the oral cavity. The viable anaerobic and aerobic bacterial counts, volatile sulfur compounds (VSCs) levels, organoleptic assessment of oral odor, and the tongue-coating index were compared at baseline, one, 5, and 9 hours after the treatment. The site-specific disinfection method reduced the VSCs and anaerobic bacterial loads while keeping the aerobic bacterial numbers higher than the traditional panoral rinsing method. Site-specific disinfection can more effectively maintain a healthy oral cavity by predominantly disinfecting the niches of anaerobic bacteria within the oral cavity.

  12. Erosion protection by calcium lactate/sodium fluoride rinses under different salivary flows in vitro.

    PubMed

    Borges, Alessandra B; Scaramucci, Taís; Lippert, Frank; Zero, Domenick T; Hara, Anderson T

    2014-01-01

    This study investigated the effect of a calcium lactate prerinse on sodium fluoride protection in an in vitro erosion-remineralization model simulating two different salivary flow rates. Enamel and dentin specimens were randomly assigned to 6 groups (n = 8), according to the combination between rinse treatments - deionized water (DIW), 12 mM NaF (NaF) or 150 mM calcium lactate followed by NaF (CaL + NaF) - and unstimulated salivary flow rates - 0.5 or 0.05 ml/min - simulating normal and low salivary flow rates, respectively. The specimens were placed into custom-made devices, creating a sealed chamber on the specimen surface connected to a peristaltic pump. Citric acid was injected into the chamber for 2 min, followed by artificial saliva (0.5 or 0.05 ml/min) for 60 min. This cycle was repeated 4×/day for 3 days. Rinse treatments were performed daily 30 min after the 1st and 4th erosive challenges, for 1 min each time. Surface loss was determined by optical profilometry. KOH-soluble fluoride and structurally bound fluoride were determined in specimens at the end of the experiment. Data were analyzed by 2-way ANOVA and Tukey tests (α = 0.05). NaF and CaL + NaF exhibited significantly lower enamel and dentin loss than DIW, with no difference between them for normal flow conditions. The low salivary flow rate increased enamel and dentin loss, except for CaL + NaF, which presented overall higher KOH-soluble and structurally bound fluoride levels. The results suggest that the NaF rinse was able to reduce erosion progression. Although the CaL prerinse considerably increased F availability, it enhanced NaF protection against dentin erosion only under hyposalivatory conditions.

  13. Application of a capsaicin rinse in the treatment of burning mouth syndrome

    PubMed Central

    Silvestre-Rangil, Javier; Tamarit-Santafé, Carmen; Bautista, Daniel

    2012-01-01

    Objective: To examine the efficacy of a new topical capsaicin presentation as an oral rinse in improving the symptoms of burning mouth syndrome (BMS). Study design: A prospective, double-blind, cross-over study was made of 30 patients with BMS. There were 7 dropouts; the final study series thus comprised 23 individuals. The patients were randomized to two groups: (A) capsaicin rinse (0.02%) or (B) placebo rinse, administered during one week. After a one-week washout period, the patients were then assigned to the opposite group. Burning discomfort was scored using a visual analog scale (VAS): in the morning before starting the treatment, in the afternoon on the first day of treatment, and at the end of the week of treatment in the morning and in the afternoon. The same scoring sequence was again applied one week later with the opposite rinse. Results: The mean patient age was 72.65 ± 12.10 years, and the duration of BMS was 5.43 ± 3.23 years on average. Significant differences in VAS score were recorded in the capsaicin group between baseline in the morning (AM1) or afternoon (AA1) and the end of the week of treatment (AA7)(p=0.003 and p=0.002, respectively). Conclusion: The topical application of capsaicin may be useful in treating the discomfort of BMS, but has some limitations. Key words: Burning mouth syndrome, stomatodynia, capsaicin, treatment, clinical management. PMID:21743415

  14. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    PubMed

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  15. Wipe-rinse technique for quantitating microbial contamination on large surfaces.

    PubMed Central

    Kirschner, L E; Puleo, J R

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2). PMID:394682

  16. Sodium hypochlorite (dilute chlorine bleach) oral rinse in patient self-care.

    PubMed

    Rich, Sandra K; Slots, Jørgen

    2015-01-01

    Sodium hypochlorite (NaOCl), commonly known as "bleach," is widely accepted as being a safe and effective antiseptic against bacteria, fungi, and viruses. For over a century, bleach has been used to control or overcome infection in homes, hospitals, and even on battlefields, and in endodontics for disinfection of root canals. This paper reviews clinical studies on the efficacy of sodium hypochlorite oral rinse to combat dental plaque and gingival inflammation. Sodium hypochlorite is readily available as inexpensive household bleach, and we suggest that oral rinsing twice weekly with dilute bleach (0.25% sodium hypochlorite) constitutes a valuable adjunct to current methods of plaque removal.

  17. The impact of chlorhexidine mouth rinse on the bond strength of polycarbonate orthodontic brackets.

    PubMed

    Hussein, Farouk Ahmed; Hashem, Mohammed Ibrahim; Chalisserry, Elna P; Anil, Sukumaran

    2014-11-01

    The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. No statistically significant difference was found in bond strengths' values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength.

  18. The effect of heparin rinse on the biocompatibility of continuous veno-venous hemodiafiltration.

    PubMed

    Opatrný, K; Polanská, K; Krouzecký, A; Vít, L; Novák, I; Kasal, E

    2002-06-01

    The aims of our cross-over randomized study were (1) to assess hemostasis in patients with acute renal failure (ARF) and (2) to determine whether or not the generally recommended heparin rinse of the extracorporeal circuit (ECC) prior to the procedure affects thrombogenicity, complement activation, and leukocyte count in blood during continuous venovenous hemodiafiltration (CVVHDF). Eleven critically ill ARF patients were treated, in random order, using CVVHDF in postdilution setup following ECC rinse with saline (A) with heparin at a concentration of 2,000 IU/L (10 procedures), (B) with heparin at a concentration of 10,000 IU/L (7 procedures), and (C) without heparin (9 procedures). Except for the rinse, anticoagulation therapy did not differ in individual patients during the procedures. Blood was withdrawn before, and at minutes 15, 60, and 360 invariably at diafilter inlet and outlet. Compared with healthy individuals, patients showed lower blood thrombocyte counts (153 vs 233*10(9)/L, p<0.01, arithmetic means, Student's t test), longer aPTT (44 vs 36 s, p<0.05), higher plasma levels of heparin (0.1 vs 0.0 U/mL, p<0.05), D-dimer (1129 vs 36 ng/mL, p<0.001) and beta-thromboglobulin (BTG) (159 vs 37 U/mL, p<0.001) prior to CVVHDF. The comparison of procedures with different rinsing technique did not reveal any significant difference in their effects on blood thrombocyte and leukocyte counts, aPTT, plasma levels of heparin, BTG, thrombin-antithrombin III complexes, D-dimer, or the C5a complement component. (1) Patients indicated for CVVHDF show impaired hemostasis involving thrombocytes, coagulation, and fibrinolysis, (2) no beneficial effect of heparin rinse on CVVHDF ECC thrombogenicity, complement activation or blood leukocyte counts was demonstrated.

  19. Ultrapure Green Light-Emitting Diodes Using Two-Dimensional Formamidinium Perovskites: Achieving Recommendation 2020 Color Coordinates.

    PubMed

    Kumar, Sudhir; Jagielski, Jakub; Kallikounis, Nikolaos; Kim, Young-Hoon; Wolf, Christoph; Jenny, Florian; Tian, Tian; Hofer, Corinne J; Chiu, Yu-Cheng; Stark, Wendelin J; Lee, Tae-Woo; Shih, Chih-Jen

    2017-09-13

    Pure green light-emitting diodes (LEDs) are essential for realizing an ultrawide color gamut in next-generation displays, as is defined by the recommendation (Rec.) 2020 standard. However, because the human eye is more sensitive to the green spectral region, it is not yet possible to achieve an ultrapure green electroluminescence (EL) with a sufficiently narrow bandwidth that covers >95% of the Rec. 2020 standard in the CIE 1931 color space. Here, we demonstrate efficient, ultrapure green EL based on the colloidal two-dimensional (2D) formamidinium lead bromide (FAPbBr 3 ) hybrid perovskites. Through the dielectric quantum well (DQW) engineering, the quantum-confined 2D FAPbBr 3 perovskites exhibit a high exciton binding energy of 162 meV, resulting in a high photoluminescence quantum yield (PLQY) of ∼92% in the spin-coated films. Our optimized LED devices show a maximum current efficiency (η CE ) of 13.02 cd A -1 and the CIE 1931 color coordinates of (0.168, 0.773). The color gamut covers 97% and 99% of the Rec. 2020 standard in the CIE 1931 and the CIE 1976 color space, respectively, representing the "greenest" LEDs ever reported. Moreover, the device shows only a ∼10% roll-off in η CE (11.3 cd A -1 ) at 1000 cd m -2 . We further demonstrate large-area (3 cm 2 ) and ultraflexible (bending radius of 2 mm) LEDs based on 2D perovskites.

  20. The AN69 ST haemodialysis membrane under conditions of two different extracorporeal circuit rinse protocols a comparison of thrombogenicity parameters.

    PubMed

    Richtrova, Pavlina; Opatrny, Karel; Vit, Ladislav; Sefrna, Frantisek; Perlik, Radek

    2007-10-01

    Thrombogenicity is an important parameter of haemodialysis (HD) membrane biocompatibility. The surface of the polyacrylonitrile AN69 ST membrane is coated with a polyethylenimine. This modification allows heparin adsorption. The binding of heparin to the membrane surface occurs during priming of the extracorporeal circuit (ECC) by rinsing it with saline and heparin. Our aims were to assess and compare the thrombogenicity of the AN69 ST membrane under conditions of two extracorporeal circuit (ECC) rinse protocols-with and without unfractionated heparin (UFH). In a prospective, crossover and randomized study, we examined 10 patients during HD after ECC preparation with either rinse protocols. Prior to HD and at 15, 60 and 240 min, we determined plasma levels of the thrombin-antithrombin complexes (TAT), platelet factor 4 (PF4), heparin concentration (antiXa) and thrombocyte count. Systemic anticoagulation was performed using UFH. During HD after ECC rinse without UFH, there was a significantly earlier and more marked increase in TAT compared with UFH-containing rinse (P <0.05). Using Spearman coefficient, we demonstrated a significant correlation between TAT and antiXa at 60 min (r = -0.534) and 240 min (r = -0.538). A comparison of the TAT/antiXa ratios between rinses at 60 min revealed a significantly higher increase in TAT following UFH-free rinse (P <0.05). There was no difference in PF4 between the rinses. Platelet count did not change significantly during HD using either rinse protocol. Based on plasma TAT levels, ECC priming with an UFH-containing solution reduces the thrombogenicity of the AN69 ST membrane. There is no significant difference between both types of priming concerning PF4 and thrombocyte count.

  1. Relative effectiveness of the Bacteriological Analytical Manual method for the recovery of Salmonella from whole cantaloupes and cantaloupe rinses with selected preenrichment media and rapid methods.

    PubMed

    Hammack, Thomas S; Valentin-Bon, Iris E; Jacobson, Andrew P; Andrews, Wallace H

    2004-05-01

    Soak and rinse methods were compared for the recovery of Salmonella from whole cantaloupes. Cantaloupes were surface inoculated with Salmonella cell suspensions and stored for 4 days at 2 to 6 degrees C. Cantaloupes were placed in sterile plastic bags with a nonselective preenrichment broth at a 1:1.5 cantaloupe weight-to-broth volume ratio. The cantaloupe broths were shaken for 5 min at 100 rpm after which 25-ml aliquots (rinse) were removed from the bags. The 25-ml rinses were preenriched in 225-ml portions of the same uninoculated broth type at 35 degrees C for 24 h (rinse method). The remaining cantaloupe broths were incubated at 35 degrees C for 24 h (soak method). The preenrichment broths used were buffered peptone water (BPW), modified BPW, lactose (LAC) broth, and Universal Preenrichment (UP) broth. The Bacteriological Analytical Manual Salmonella culture method was compared with the following rapid methods: the TECRA Unique Salmonella method, the VIDAS ICS/SLM method, and the VIDAS SLM method. The soak method detected significantly more Salmonella-positive cantaloupes (P < 0.05) than did the rinse method: 367 Salmonella-positive cantaloupes of 540 test cantaloupes by the soak method and 24 Salmonella-positive cantaloupes of 540 test cantaloupes by the rinse method. Overall, BPW, LAC, and UP broths were equivalent for the recovery of Salmonella from cantaloupes. Both the VIDAS ICS/SLM and TECRA Unique Salmonella methods detected significantly fewer Salmonella-positive cantaloupes than did the culture method: the VIDAS ICS/SLM method detected 23 of 50 Salmonella-positive cantaloupes (60 tested) and the TECRA Unique Salmonella method detected 16 of 29 Salmonella-positive cantaloupes (60 tested). The VIDAS SLM and culture methods were equivalent: both methods detected 37 of 37 Salmonella-positive cantaloupes (60 tested).

  2. Comparison of Promoter Hypermethylation Pattern in Salivary Rinses Collected with and without an Exfoliating Brush from Patients with HNSCC

    PubMed Central

    Sun, Wenyue; Zaboli, David; Liu, Yan; Arnaoutakis, Demetri; Khan, Tanbir; Wang, Hao; Koch, Wayne; Khan, Zubair; Califano, Joseph A.

    2012-01-01

    Background Salivary rinses have been recently proposed as a valuable resource for the development of epigenetic biomarkers for detection and monitoring of head and neck squamous cell carcinoma (HNSCC). Both salivary rinses collected with and without an exfoliating brush from patients with HNSCC are used in detection of promoter hypermethylation, yet their correlation of promoter hypermethylation has not been evaluated. This study was to evaluate the concordance of promoter hypermethylation between salivary rinses collected with and without an exfoliating brush from patients with HNSCC. Methodolgy 57 paired salivary rinses collected with or without an exfoliating brush from identical HNSCC patients were evaluated for promoter hypermethylation status using Quantitative Methylation-Specific PCR. Target tumor suppressor gene promoter regions were selected based on our previous studies describing a panel for HNSCC screening and surveillance, including P16, CCNA1, DCC, TIMP3, MGMT, DAPK and MINT31. Principal Findings In salivary rinses collected with and without brush, frequent methylation was detected in P16 (8.8% vs. 5.2%), CCNA1 (26.3% vs. 22.8%), DCC (33.3% vs. 29.8%), TIMP3 (31.6% vs. 36.8%), MGMT (29.8% vs. 38.6%), DAPK (14.0% vs. 19.2%), and MINT31 (10.5% vs. 8.8%). Spearman's rank correlation coefficient showed a positive correlation between salivary rinses collected with and without brush for P16 (ρ = 0.79), CCNA1 (ρ = 0.61), DCC (ρ = 0.58), TIMP3 (ρ = 0.10), MGMT (ρ = 0.70), DAPK (ρ = 0.51) and MINT31 (ρ = 0.72) (P<0.01). The percent agreement of promoter methylation between salivary rinses with brush and without brush were 96.5% for P16, 82.5% for CCNA1, 78.9% for DCC, 59.7% for TIMP3, 84.2% for MGMT, 84.2% for DAPK, and 94.7% for MINT31. Conclusions Our study demonstrated strong correlations of gene promoter hypermethylation between salivary rinses collected with and without an exfoliating brush. Salivary rinse collection

  3. Testing of duplicate rinse aliquots for presence of Salmonella

    USDA-ARS?s Scientific Manuscript database

    Testing of chicken carcass rinses for Salmonella prevalence is often performed in duplicate because of the potential importance of the results, but anecdotal reports indicate that duplicate samples often disagree. This might be due to normal variation in microbiological methods or to the testing of...

  4. The comparative effects of 0.12% chlorhexidine and herbal oral rinse on dental plaque-induced gingivitis: A randomized clinical trial

    PubMed Central

    Bhate, Devaki; Jain, Sanjay; Kale, Rahul; Muglikar, Sangeeta

    2015-01-01

    Background: Chlorhexidine (CHX) is considered as a gold standard of antimicrobial rinses. Various herbal oral rinses are available in the market. However, little is known of its effectiveness. Aim: The aim of this study was to evaluate the clinical changes after the usage of herbal oral rinse and 0.12% CHX. Materials and Methods: In a randomized clinical trial, 76 patients with dental plaque-induced gingivitis were assigned to Group I (Herbal Oral Rinse - Hiora®) and 76 patients with dental plaque-induced gingivitis to Group II (0.12% Chlorhexidine-Peridex®). Gingival index and Plaque index scores were recorded at baseline and 21 days after scaling. Results: Intragroup comparison in both groups showed that plaque index and gingival index scores were statistically significant after 21 days as compared to baseline. Intergroup comparison showed that plaque index scores and gingival index scores were statistically significant in Group II as compared to Group I. Conclusion: When herbal oral rinse was compared to 0.12% CHX, 0.12% CHX mouth rinse effectively reduced the clinical symptoms of plaque-induced gingivitis. PMID:26392686

  5. Resist surface crosslinking using amine-based reactive rinses to mitagate pattern collapse in thin film lithography

    NASA Astrophysics Data System (ADS)

    Yeh, Wei-Ming; Lawson, Richard A.; Tolbert, Laren M.; Henderson, Clifford L.

    2012-03-01

    As the semiconductor industry continues to push to smaller critical dimensions, pattern collapse during lithographic processing caused by unbalanced capillary forces during the final rinse and drying process has become an important problem that can limit the practical resolution of a resist material to feature sizes larger than its intrinsic resolution limit. One of the primary modes of pattern collapse is via elastoplastic pattern deformation which is strongly related to the mechanical properties of the resist. One approach to mitigating such collapse problems is to enhance the mechanical properties of the resist features. Since such modification of resist physical properties for pattern collapse purposes is difficult to achieve through modified formulation of the resist itself (i.e. due to the complex set of requirements that a resist must satisfy and the complex set of physical and chemical phenomena that underlie the imaging processing itself), we have pursued an alternative strategy for improving the resist mechanical properties after features are developed in the film but before they are rinsed and dried. The family of techniques being developed in this work function through the use of aqueous compatible reactive rinse solutions that can be applied to developed resist features while they are wet during normal rinse processing on a track system. By applying these techniques during the rinse process, the resist features can be strengthened before they are subjected to significant capillary forces during the final drying step. In this work, the use of diamine compounds to reactively crosslink the surface of resists containing carboxylic acid groups through formation of amide bonds using carbodiimide chemistry has been explored. One advantage of this approach is that it is an aqueous process that should be easily compatible with high volume, track-based lithographic processes. Contact angle studies and x-ray photoelectron spectroscopy (XPS) were used to

  6. The effect of three whitening oral rinses on enamel micro-hardness.

    PubMed

    Potgieter, E; Osman, Y; Grobler, S R

    2014-05-01

    The purpose of this study was to determine the effect on human enamel micro-hardness of three over-the-counter whitening oral rinses available in South Africa. Enamel fragments were gathered into three groups of 15 each. One group was exposed to Colgate Plax Whitening Blancheur, the second group to White Glo 2 in 1 and the third to Plus White, in each case for periods recommended by the respective manufacturers. Surface micro-hardness of all groups was measured before and after a 14 day treatment period. pH levels of the oral rinses were also determined with a combination pH electrode. Pre- and post- treatment data were analysed by the Wilcoxon Signed Rank Sum Test. According to the micro-hardness values no significant (p > 0.05) enamel damage was found as a result of treatment. However, it was observed that Colgate Pax and White Glo decreased the enamel hardness, an early sign of enamel damage, while Plus White showed a small increase in hardness. The three whitening oral rinses on the South African market do not damage the tooth enamel significantly when used as recommended by the manufacturers. However, extending the contact period and increasing the frequency of application might lead to damage of enamel.

  7. The effect of a calcium phosphate mouth rinse on (chemo) radiation induced oral mucositis in head and neck cancer patients: a prospective study.

    PubMed

    Stokman, M A; Burlage, F R; Spijkervet, F K L

    2012-08-01

    Promising results of a calcium phosphate (CP) mouth rinse on reduced severity of oral mucositis have been reported. The aim of this study was to determine the effect of a CP mouth rinse on the frequency, duration and severity of (chemo) radiation induced oral mucositis in patients with head-neck cancer. patients with oral malignancies, treated with (chemo) radiotherapy, were included. Patients rinsed four times a day with a CP mouth rinse. Patients not willing to rinse with the CP mouth rinse served as control. Mucositis was scored according to the WHO score at baseline and twice a week during the full course of (chemo) radiotherapy. Patient's self-reported mouth-throat soreness (MTS) was evaluated at the same time interval using a diary in the CP mouth rinse group. The outcomes on MTS were compared with a historical control group. Fifty-two patients were analysed: 25 CP mouth rinse group, 11 control group and 16 historical group. There was no significant difference between the CP group and control group on development and severity of oral mucositis. No significant difference was found for subjective outcomes on MTS between the CP group and the historical group. The CP mouth rinse seems to have no influence on the frequency, duration and severity of oral mucositis during (chemo) radiation in patients with head and neck cancer. A trend to develop less MTS for drinking and eating was found when applying the CP mouth rinse. © 2012 John Wiley & Sons A/S.

  8. Ultrapure glass optical waveguide development in microgravity by the sol-gel process

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Containerless melting of glasses in space for the preparation of ultrapure homogeneous glass for optical waveguides is discussed. The homogenization of the glass using conventional raw materials is normally achieved on Earth either by the gravity induced convection currents or by the mechanical stirring of the melt. Because of the absence of gravity induced convection currents, the homogenization of glass using convectional raw materials is difficult in the space environment. Multicomponent, homogeneous, noncrystalline oxide gels can be prepared by the sol-gel process and these gels are promising starting materials for melting glasses in the space environment. The sol-gel process is based on the polymerization reaction of alkoxysilane with other metal alkoxy compounds or suitable metal salts. Many of the alkoxysilanes or other metal alkoxides are liquids and thus can be purified by distillation.

  9. Field investigation of arsenic in ceramic pot filter-treated drinking water.

    PubMed

    Archer, A R; Elmore, A C; Bell, E; Rozycki, C

    2011-01-01

    Ceramic pot filters (CPFs) is one of several household water treatment technologies that is used to treat drinking water in developing areas. The filters have the advantage of being able to be manufactured using primarily locally available materials and local labor. However, naturally-occurring arsenic present in the clay used to make the filters has the potential to contaminate the water in excess of the World Health Organization drinking water standard of 0.01 mg/L. A manufacturing facility in Guatemala routinely rinses filters to reduce arsenic concentrations prior to distribution to consumers. A systemic study was performed to evaluate the change in arsenic concentrations with increasing volumes of rinse water. Arsenic field kit results were compared to standard method laboratory results, and dissolved versus suspended arsenic concentrations in CPF-treated water were evaluated. The results of the study suggest that rinsing is an effective means of mitigating arsenic leached from the filters, and that even in the absence of a formal rinsing program, routine consumer use may result in the rapid decline of arsenic concentrations. More importantly, the results indicate that filter manufacturers should give strong consideration to implementing an arsenic testing program.

  10. Rinse-resistant superhydrophobic block copolymer fabrics by electrospinning, electrospraying and thermally-induced self-assembly

    NASA Astrophysics Data System (ADS)

    Wu, Jie; Li, Xin; Wu, Yang; Liao, Guoxing; Johnston, Priscilla; Topham, Paul D.; Wang, Linge

    2017-11-01

    An inherent problem that restricts the practical application of superhydrophobic materials is that the superhydrophobic property is not sustainable; it can be diminished, or even lost, when the surface is physically damaged. In this work, we present an efficient approach for the fabrication of superhydrophobic fibrous fabrics with great rinse-resistance where a block copolymer has been electrospun into a nanofibrous mesh while micro-sized beads have been subsequently electrosprayed to give a morphologically composite material. The intricate nano- and microstructure of the composite was then fixed by thermally annealing the block copolymer to induce self-assembly and interdigitation of the microphase separated domains. To demonstrate this approach, a polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) nanofibrous scaffold was produced by electrospinning before SEBS beads were electrosprayed into this mesh to form a hierarchical micro/nanostructure of beads and fibers. The effects of type and density of SEBS beads on the surface morphology and wetting properties of composite membranes were studied extensively. Compared with a neat SEBS fibrous mesh, the composite membrane had enhanced hydrophobic properties. The static water contact angle increased from 139° (±3°) to 156° (±1°), while the sliding angle decreased to 8° (±1°) from nearly 90°. In order to increase the rinse-resistance of the composite membrane, a thermal annealing step was applied to physically bind the fibers and beads. Importantly, after 200 h of water flushing, the hierarchical surface structure and superhydrophobicity of the composite membrane were well retained. This work provides a new route for the creation of superhydrophobic fabrics with potential in self-cleaning applications.

  11. In vivo antiplaque efficacy of combined antimicrobial dentifrice and rinse hygiene regimens.

    PubMed

    White, Donald J; Barker, Matthew L; Klukowska, Malgorzata

    2008-06-01

    To evaluate using digital plaque image analysis the antiplaque efficacy of oral care regimens including use of antimicrobial toothpaste in combination with antimicrobial mouthrinse. 16 subjects completed the study protocol including: (1) initial treatment phase, all subjects used a standard sodium fluoride dentifrice with 2x/day brushing, (2) second treatment phase, subjects were randomized to two treatment groups: stannous fluoride/sodium hexametaphosphate dentifrice or sodium fluoride triclosan/copolymer dentifrice; (3) third treatment phase, the group using stannous fluoride dentifrice rinsed with alcohol-free cetylpyridinium chloride mouthrinse and the group using triclosan dentifrice rinsed with essential oil mouthrinse. During each phase, plaque levels were assessed in the morning before toothbrushing (AM), post-brushing in the morning (PB) and in the afternoon (PM). Stannous fluoride dentifrice was superior to triclosan dentifrice in plaque growth inhibition between toothbrushing. Both mouthrinses provided additional plaque prevention benefits when used with antimicrobial dentifrices. The cetylpyridinium chloride mouthrinse and stannous fluoride dentifrice regimen was particularly effective, building accretive efficacy over time. Average plaque reductions exceeded 50% vs. sodium fluoride dentifrice alone. Chemotherapeutic dentifrices and rinses increase plaque control used alone and particularly in combination. The stannous fluoride-cetylpyridinium chloride regimen showed the greatest benefits.

  12. Removal of bromide and bromate from drinking water using granular activated carbon.

    PubMed

    Zhang, Yong-Qing; Wu, Qing-Ping; Zhang, Ju-Mei; Yang, Xiu-Hua

    2015-03-01

    Granular activated carbon (GAC) was used to remove bromide (Br⁻) and bromate (BrO(3)(-)) from drinking water in both bench- and pilot-scale experiments. The present study aims to minimize BrO(3)(-) formation and eliminate BrO(3)(-) generated during the ozonation of drinking water, particularly in packaged drinking water. Results show that the Br⁻ and BrO(3)(-) levels in GAC-treated water decreased in both bench- and pilot-scale experiments. In the bench-scale experiments, when the empty bed contact time (EBCT) was 5 min, the highest reduction rates of Br(-) in the mineral and ultrapure water were found to be 74.9% and 91.2%, respectively, and those of BrO(3)(-) were 94.4% and 98.8%, respectively. The GAC capacity for Br⁻ and BrO(3)(-) removal increased with the increase in EBCT. Reduction efficiency was better in ultrapure water than in mineral water. In the pilot-scale experiments, the minimum reduction rates of Br⁻ and BrO(3)(-) were 38.5% and 73.2%, respectively.

  13. Optimization of the etch-and-rinse technique: New perspectives to improve resin-dentin bonding and hybrid layer integrity by reducing residual water using dimethyl sulfoxide pretreatments.

    PubMed

    Stape, Thiago Henrique Scarabello; Tjäderhane, Leo; Abuna, Gabriel; Sinhoreti, Mário Alexandre Coelho; Martins, Luís Roberto Marcondes; Tezvergil-Mutluay, Arzu

    2018-04-13

    To determine whether bonding effectiveness and hybrid layer integrity on acid-etched dehydrated dentin would be comparable to the conventional wet-bonding technique through new dentin biomodification approaches using dimethyl sulfoxide (DMSO). Etched dentin surfaces from extracted sound molars were randomly bonded in wet or dry conditions (30s air drying) with DMSO/ethanol or DMSO/H 2 O as pretreatments using a simplified (Scotchbond Universal Adhesive, 3M ESPE: SU) and a multi-step (Adper Scotchbond Multi-Purpose, 3M ESPE: SBMP) etch-and-rinse adhesives. Untreated dentin surfaces served as control. Bonded teeth (n=8) were stored in distilled water for 24h and sectioned into resin-dentin beams (0.8mm 2 ) for microtensile bond strength test and quantitative interfacial nanoleakage analysis (n=8) under SEM. Additional teeth (n=2) were prepared for micropermeability assessment by CFLSM under simulated pulpar pressure (20cm H 2 O) using 5mM fluorescein as a tracer. Microtensile data was analyzed by 3-way ANOVA followed by Tukey Test and nanoleakage by Kruskal-Wallis and Dunn-Bonferroni multiple comparison test (α=0.05). While dry-bonding of SBMP produced significantly lower bond strengths than wet-bonding (p<0.05), DMSO/H 2 O and DMSO/ethanol produced significantly higher bond strengths for SBMP irrespective of dentin condition (p<0.05). SU presented significantly higher nanoleakage levels (p<0.05) and micropermeability than SBMP. Improvement in hybrid layer integrity occurred for SBMP and SU for both pretreatments, albeit most pronouncedly for DMSO/ethanol regardless of dentin moisture. DMSO pretreatments may be used as a new suitable strategy to improve bonding of water-based adhesives to demineralized air-dried dentin beyond conventional wet-bonding. Less porous resin-dentin interfaces with higher bond strengths on air-dried etched dentin were achieved; nonetheless, overall efficiency varied according to DMSO's co-solvent and adhesive type. DMSO pretreatments

  14. Mouth Rinsing with Maltodextrin Solutions Fails to Improve Time Trial Endurance Cycling Performance in Recreational Athletes.

    PubMed

    Kulaksız, Tuğba Nilay; Koşar, Şükran Nazan; Bulut, Suleyman; Güzel, Yasemin; Willems, Marcus Elisabeth Theodorus; Hazir, Tahir; Turnagöl, Hüseyin Hüsrev

    2016-05-09

    The carbohydrate (CHO) concentration of a mouth rinsing solution might influence the CHO sensing receptors in the mouth, with consequent activation of brain regions involved in reward, motivation and regulation of motor activity. The purpose of the present study was to examine the effects of maltodextrin mouth rinsing with different concentrations (3%, 6% and 12%) after an overnight fast on a 20 km cycling time trial performance. Nine recreationally active, healthy males (age: 24 ± 2 years; V ˙ O 2 m a x : 47 ± 5 mL·kg(-1)·min(-1)) participated in this study. A double-blind, placebo-controlled randomized study was conducted. Participants mouth-rinsed every 2.5 km for 5 s. Maltodextrin mouth rinse with concentrations of 3%, 6% or 12% did not change time to complete the time trial and power output compared to placebo (p > 0.05). Time trial completion times were 40.2 ± 4.0, 40.1 ± 3.9, 40.1 ± 4.4, and 39.3 ± 4.2 min and power output 205 ± 22, 206 ± 25, 210 ± 24, and 205 ± 23 W for placebo, 3%, 6%, and 12% maltodextrin conditions, respectively. Heart rate, lactate, glucose, and rating of perceived exertion did not differ between trials (p > 0.05). In conclusion, mouth rinsing with different maltodextrin concentrations after an overnight fast did not affect the physiological responses and performance during a 20 km cycling time trial in recreationally active males.

  15. Automated Immunomagnetic Separation and Microarray Detection of E. coli O157:H7 from Poultry Carcass Rinse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandler, Darrell P.; Brown, Jeremy D.; Call, Douglas R.

    2001-09-01

    We describe the development and application of a novel electromagnetic flow cell and fluidics system for automated immunomagnetic separation of E. coli directly from unprocessed poultry carcass rinse, and the biochemical coupling of automated sample preparation with nucleic acid microarrays without cell growth. Highly porous nickel foam was used as a magnetic flux conductor. Up to 32% recovery efficiency of 'total' E. coli was achieved within the automated system with 6 sec contact times and 15 minute protocol (from sample injection through elution), statistically similar to cell recovery efficiencies in > 1 hour 'batch' captures. The electromagnet flow cell allowedmore » complete recovery of 2.8 mm particles directly from unprocessed poultry carcass rinse whereas the batch system did not. O157:H7 cells were reproducibly isolated directly from unprocessed poultry rinse with 39% recovery efficiency at 103 cells ml-1 inoculum. Direct plating of washed beads showed positive recovery of O 157:H7 directly from carcass rinse at an inoculum of 10 cells ml-1. Recovered beads were used for direct PCR amplification and microarray detection, with a process-level detection limit (automated cell concentration through microarray detection) of < 103 cells ml-1 carcass rinse. The fluidic system and analytical approach described here are generally applicable to most microbial detection problems and applications.« less

  16. Comparison of the antimicrobial efficacy of chlorhexidine, sodium fluoride, fluoride with essential oils, alum, green tea, and garlic with lime mouth rinses on cariogenic microbes.

    PubMed

    Thomas, Ann; Thakur, Sneha; Mhambrey, Sanjana

    2015-01-01

    A number of natural mouth rinse formulations are being proposed as an alternative to the widely used chemical mouth rinses. To evaluate and compare the antimicrobial efficacy of chlorhexidine (0.2%), sodium fluoride (0.05%), fluoride with essential oils (0.05%), alum (0.02 M), green tea, and garlic with lime mouth rinses against Streptococcus mutans, lactobacilli, and Candida albicans. The three microbes were isolated from the saliva samples collected from children with severe early childhood caries. The zone of minimum inhibition was assessed using agar diffusion method. The data were statistically analyzed using SPSS software. Against S. mutans and lactobacilli, chlorhexidine mouth rinse was found to be the most effective as compared to sodium fluoride (P < 0.001, P < 0.001), fluoride with essential oils (P < 0.001, P < 0.001), alum (P < 0.001, P < 0.001), green tea (P < 0.001, P < 0.001), and garlic with lime (P < 0.001, P < 0.001) mouth rinses, respectively. But against C. albicans, garlic with lime mouth rinse was found to be the most effective as compared to chlorhexidine (P < 0.001), sodium fluoride (P < 0.001), fluoride with essential oils (P < 0.001), alum (P < 0.001), and green tea (P < 0.001) mouth rinses. Against S. mutans and lactobacilli, after chlorhexidine mouth rinse, garlic with lime mouth rinse was found to be significantly more effective than sodium fluoride (P = 0.053, P = 0.001), fluoride with essential oils (P < 0.001, P < 0.001), alum (P < 0.001, P < 0.001), and green tea (P < 0.001, P < 0.001) mouth rinses. As a natural mouth rinse, garlic with lime mouth rinse was found to be the most promising. However, further studies are needed in this field.

  17. Cleaning by Surfactant Gradients: Particulate Removal from Porous Materials and the Significance of Rinsing in Laundry Detergency

    NASA Astrophysics Data System (ADS)

    Shin, Sangwoo; Warren, Patrick B.; Stone, Howard A.

    2018-03-01

    Removing particles from fibrous materials involves loosening via surfactants followed by particle transfer in a flow. While flow advection is commonly believed to be the major driver for pore-scale transport, small pores within the fabric do not allow any significant fluid flow inside them, thus significantly reducing the role of advection. However, rinsing the fabric with fresh water naturally establishes a surfactant gradient within the pore space, providing a suitable environment for particles to undergo diffusiophoresis. We demonstrate that this mechanism can remove particles from deep within fabric pores at an accelerated rate. The nonlinear aspect of diffusiophoresis significantly prolongs the lifetime of the phoretic motion beyond the naive solute diffusion time scale during rinsing, allowing long-lasting, continuous removal of particles. Moreover, owing to the fine balance between chemiphoresis and electrophoresis for particles in anionic surfactant concentration gradients, we show that the particle removal is sensitive to the counterion mobility, suggesting a simple route to control the effect. We thus claim to have resolved the "stagnant core problem"—a long-standing mystery in laundry detergency—and have identified a physicochemical approach to particle transport in fibrous media with broad applicability.

  18. Study of residue type defect formation mechanism and the effect of advanced defect reduction (ADR) rinse process

    NASA Astrophysics Data System (ADS)

    Arima, Hiroshi; Yoshida, Yuichi; Yoshihara, Kosuke; Shibata, Tsuyoshi; Kushida, Yuki; Nakagawa, Hiroki; Nishimura, Yukio; Yamaguchi, Yoshikazu

    2009-03-01

    Residue type defect is one of yield detractors in lithography process. It is known that occurrence of the residue type defect is dependent on resist development process and the defect is reduced by optimized rinsing condition. However, the defect formation is affected by resist materials and substrate conditions. Therefore, it is necessary to optimize the development process condition by each mask level. Those optimization steps require a large amount of time and effort. The formation mechanism is investigated from viewpoint of both material and process. The defect formation is affected by resist material types, substrate condition and development process condition (D.I.W. rinse step). Optimized resist formulation and new rinse technology significantly reduce the residue type defect.

  19. Reliable solution processed planar perovskite hybrid solar cells with large-area uniformity by chloroform soaking and spin rinsing induced surface precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chern, Yann-Cherng; Wu, Hung-Ruei; Chen, Yen-Chu

    2015-08-15

    A solvent soaking and rinsing method, in which the solvent was allowed to soak all over the surface followed by a spinning for solvent draining, was found to produce perovskite layers with high uniformity on a centimeter scale and with much improved reliability. Besides the enhanced crystallinity and surface morphology due to the rinsing induced surface precipitation that constrains the grain growth underneath in the precursor films, large-area uniformity with film thickness determined exclusively by the rotational speed of rinsing spinning for solvent draining was observed. With chloroform as rinsing solvent, highly uniform and mirror-like perovskite layers of area asmore » large as 8 cm × 8 cm were produced and highly uniform planar perovskite solar cells with power conversion efficiency of 10.6 ± 0.2% as well as much prolonged lifetime were obtained. The high uniformity and reliability observed with this solvent soaking and rinsing method were ascribed to the low viscosity of chloroform as well as its feasibility of mixing with the solvent used in the precursor solution. Moreover, since the surface precipitation forms before the solvent draining, this solvent soaking and rinsing method may be adapted to spinless process and be compatible with large-area and continuous production. With the large-area uniformity and reliability for the resultant perovskite layers, this chloroform soaking and rinsing approach may thus be promising for the mass production and commercialization of large-area perovskite solar cells.« less

  20. The long-term effect of a zinc acetate and chlorhexidine diacetate containing mouth rinse on intra-oral halitosis-A randomized clinical trial.

    PubMed

    Erovic Ademovski, Seida; Mårtensson, Carina; Persson, Gösta Rutger; Renvert, Stefan

    2017-10-01

    To evaluate the long-term effects of a zinc acetate and chlorhexidine diacetate mouth rinse (Zn/CHX) on intra-oral halitosis. Forty-six adults with intra-oral halitosis were randomized into a 6-month, double-blind, placebo-controlled clinical study. The presence of intra-oral halitosis was evaluated at baseline, 3 and 6 months after treatment by assessment of organoleptic score (OLS) and by total volatile sulphur compounds (T-VSC), hydrogen sulphide (H 2 S) and methyl mercaptan (MM) concentrations in exhaled air. A Zn/CHX mouth rinse provided significantly better control of intra-oral halitosis than a placebo mouth rinse. At 3 and 6 months, individuals rinsing with the Zn/CHX rinse presented with reductions of the OLS, T-VSC (p < .01, respectively), H 2 S (p < .001), and MM (p < .01) in subjects' exhaled air. At 6 months, 68.2% of individuals using the Zn/CHX rinse experienced a 1 or 2 category improvement in OLS compared with 19.1% of placebo-treated subjects. 91% of subjects in the Zn/CHX group were categorized as being effectively treated for intra-oral halitosis (i.e. H 2 S < 112 ppb), compared to 43% in the placebo group. Zn/CHX mouth rinse provides effective long-term efficacy against intra-oral halitosis, assessed both objectively and subjectively. With regular rinsing, the effect was sustained for 6 months. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Clinical and Microbial Evaluation of the Effects on Gingivitis of a Mouth Rinse Containing an Enteromorpha linza Extract

    PubMed Central

    Cho, Han-Bin; Lee, Hee-Hyun; Lee, Ok-Hwan; Choi, Hyeon-Son; Choi, Jae-Suk

    2011-01-01

    Abstract Enteromorpha linza, a green alga, has been recognized as a potential source of natural antimicrobial and antifungal compounds. We previously reported that an E. linza extract strongly inhibited the growth of Prevotella intermedia and Porphyromonas gingivalis. The principal objective of this study was to evaluate the clinical effect of a mouth rinse containing the E. linza extract on gingivitis disease, as measured by the plaque index (PI), gingival index (GI), and bleeding on probing (BOP), and on two bacterial strains (P. intermedia and P. gingivalis), in comparison with Listerine® (Listerine-Korea, Seoul, Korea), which was used as a positive control. In total, 55 subjects were recruited into active participation in this clinical study. The PI, GI, BOP, and bacterial strains were then evaluated over a test period of 6 weeks. After 1, 2, 4, and 6 weeks, the same clinical indices were recorded, and the levels of P. intermedia and P. gingivalis were quantified via real-time polymerase chain reaction. At the end of the study, the group using the mouth rinse containing the E. linza extract evidenced significant reductions in the clinical indices (PI, GI, and BOP) and P. gingivalis compared with baseline values. Moreover, E. linza extract containing mouth rinse produced effects similar to those of Listerine. Overall, these results indicate that a mouth rinse containing E. linza extract significantly reduces plaque, improves the condition of gingival tissues, and reduces bleeding. Additionally, E. linza extract mouth rinse significantly inhibits P. gingivalis and P. intermedia. Thus, this clinical study demonstrated that the twice-daily use of an E. linza extract mouth rinse can inhibit and prevent gingivitis. PMID:22145775

  2. A tradeoff study of determine the optimum approach to a wash/rinse capability to support future space flight

    NASA Technical Reports Server (NTRS)

    Wilson, D. A.

    1976-01-01

    Specific requirements for a wash/rinse capability to support Spacelab biological experimentation and to identify various concepts for achieving this capability were determined. This included the examination of current state-of-the-art and emerging technology designs that would meet the wash/rinse requirements. Once several concepts were identified, including the disposable utensils, tools and gloves or other possible alternatives, a tradeoff analysis involving system cost, weight, volume utilization, functional performance, maintainability, reliability, power utilization, safety, complexity, etc., was performed so as to determine an optimum approach for achieving a wash/rinse capability to support future space flights. Missions of varying crew size and durations were considered.

  3. Effects of etch-and-rinse and self-etch adhesives on dentin MMP-2 and MMP-9.

    PubMed

    Mazzoni, A; Scaffa, P; Carrilho, M; Tjäderhane, L; Di Lenarda, R; Polimeni, A; Tezvergil-Mutluay, A; Tay, F R; Pashley, D H; Breschi, L

    2013-01-01

    Auto-degradation of collagen matrices occurs within hybrid layers created by contemporary dentin bonding systems, by the slow action of host-derived matrix metalloproteinases (MMPs). This study tested the null hypothesis that there are no differences in the activities of MMP-2 and -9 after treatment with different etch-and-rinse or self-etch adhesives. Tested adhesives were: Adper Scotchbond 1XT (3M ESPE), PQ1 (Ultradent), Peak LC (Ultradent), Optibond Solo Plus (Kerr), Prime&Bond NT (Dentsply) (all 2-step etch-and-rinse adhesives), and Adper Easy Bond (3M ESPE), Tri-S (Kuraray), and Xeno-V (Dentsply) (1-step self-etch adhesives). MMP-2 and -9 activities were quantified in adhesive-treated dentin powder by means of an activity assay and gelatin zymography. MMP-2 and MMP-9 activities were found after treatment with all of the simplified etch-and-rinse and self-etch adhesives; however, the activation was adhesive-dependent. It is concluded that all two-step etch-and-rinse and the one-step self-etch adhesives tested can activate endogenous MMP-2 and MMP-9 in human dentin. These results support the role of endogenous MMPs in the degradation of hybrid layers created by these adhesives.

  4. Effects of Etch-and-Rinse and Self-etch Adhesives on Dentin MMP-2 and MMP-9

    PubMed Central

    Mazzoni, A.; Scaffa, P.; Carrilho, M.; Tjäderhane, L.; Di Lenarda, R.; Polimeni, A.; Tezvergil-Mutluay, A.; Tay, F.R.; Pashley, D.H.; Breschi, L.

    2013-01-01

    Auto-degradation of collagen matrices occurs within hybrid layers created by contemporary dentin bonding systems, by the slow action of host-derived matrix metalloproteinases (MMPs). This study tested the null hypothesis that there are no differences in the activities of MMP-2 and -9 after treatment with different etch-and-rinse or self-etch adhesives. Tested adhesives were: Adper Scotchbond 1XT (3M ESPE), PQ1 (Ultradent), Peak LC (Ultradent), Optibond Solo Plus (Kerr), Prime&Bond NT (Dentsply) (all 2-step etch-and-rinse adhesives), and Adper Easy Bond (3M ESPE), Tri-S (Kuraray), and Xeno-V (Dentsply) (1-step self-etch adhesives). MMP-2 and -9 activities were quantified in adhesive-treated dentin powder by means of an activity assay and gelatin zymography. MMP-2 and MMP-9 activities were found after treatment with all of the simplified etch-and-rinse and self-etch adhesives; however, the activation was adhesive-dependent. It is concluded that all two-step etch-and-rinse and the one-step self-etch adhesives tested can activate endogenous MMP-2 and MMP-9 in human dentin. These results support the role of endogenous MMPs in the degradation of hybrid layers created by these adhesives. PMID:23128110

  5. Development of a solid-phase microextraction gas chromatography with microelectron-capture detection method for the determination of 5-bromo-5-nitro-1,3-dioxane in rinse-off cosmetics.

    PubMed

    Fernandez-Alvarez, Maria; Lamas, J Pablo; Sanchez-Prado, Lucia; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2010-10-22

    5-Bromo-5-nitro-1,3-dioxane (bronidox) is a bromine-containing preservative often used in rinse-off cosmetics but also subjected to several restrictions according to the European Cosmetic Products Regulation. Thus, as a part of a quality control procedure, analytical methods for the determination of this compound in different types of cosmetics are required. In the present work, a solvent-free and simple methodology based on solid-phase microextraction (SPME) followed by gas chromatography with microelectron capture detection (GC-μECD) has been developed and validated for the determination of bronidox in cosmetic samples such as shampoos, body cleansers or facial exfoliants. As far as we know, this is the first application of SPME to this preservative. Negative matrix effects due to the complexity of the studied samples were reduced by dilution with ultrapure water. The influence of several factors on the SPME procedure such as fiber coating, extraction temperature, salt addition (NaCl) and sampling mode has been assessed by performing a 2(4)-factorial design. After optimization, the recommended procedure was established as follows: direct solid-phase microextraction (DSPME), using a PDMS/DVB coating, of 10 mL of diluted cosmetic with 20% NaCl, at room temperature, under stirring for 30 min. Using these suggested extraction conditions, linear calibration could be achieved, with limits of detection (LOD) and quantification (LOQ) well below the maximum authorized concentration (0.1%) established by the European legislation. Relative standard deviations (RSD) lower than 10% were obtained for both within a day and among days precision. The method was applied to diverse types of formulations spiked with bronidox at different concentration levels (0.008-0.10%); these samples were quantified by external calibration and satisfactory recoveries (≥ 70%) were obtained in all cases. Finally, the SPME-GC-μECD methodology was applied to the analysis of several cosmetics

  6. Effect of a new pre-brushing rinse on dental plaque removal.

    PubMed

    Vouros, J; Sakellari, D; Konstantinidis, A

    1994-11-01

    Non-prescription prebrushing rinses to facilitate dental plaque removal have been advertised in recent years. The purpose of the present study was to determine the plaque removal effectiveness of Plax (Colgate) prebrushing rinse by comparing it to a placebo solution. 19 dental students volunteered for this double blind study which consisted of 2 experimental periods. The following procedure was followed: 3 weeks after scaling and polishing, the participants abstained from oral hygiene for 3 days to allow dental plaque to accumulate. After plaque disclosing, the 4 mandibular incisors were photographed using a strictly defined technique, as described by Quirynen et al. Then the volunteers mouthrinsed for 30 s with 15 ml of a solution provided to them. Neither the volunteers nor the examiners knew which solution (test or control) was used. After mouthrinsing, the participants were allowed to brush their teeth and the remaining plaque was photographed again. During the 2nd experimental period, the same procedure was followed, and the 2nd solution was used for mouthrinsing. The effectiveness of the solutions was evaluated by comparing the proportion of dental plaque removed during the 2 experimental periods. The area of dental plaque was measured by an electronic high-precision device (planimeter). The proportion of plaque removed after rinsing with Plax was 0.40 +/- 0.23 and after rising with placebo 0.42 +/- 0.24, of the tooth surface (p = 0.962). Analysis of data by means of paired t-test between the 2 experimental periods revealed no beneficial effect regarding plaque removal when Plax was used.

  7. Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers.

    PubMed

    Zimmerman, Aaron B; Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T; Lam, Dawn Y; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L; Collier, Sarah A; Cope, Jennifer R; Rao, Maya M; Beach, Michael J; Yoder, Jonathan S

    2017-08-01

    To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk.

  8. Improvement of Karmali agar by addition of polymyxin B for the detection of Campylobacter jejuni and C. coli in whole-chicken carcass rinse.

    PubMed

    Chon, Jung-Whan; Kim, Hyunsook; Yim, Jin-Hyeok; Song, Kwang-Young; Moon, Jin-San; Kim, Young-Jo; Seo, Kun-Ho

    2013-05-01

    The Karmali agar was modified by supplementation with a high concentration of polymyxin B. The goal of the study was to evaluate the effect of a high concentration of polymyxin B on the ability and selectivity of the modified Karmali agar to isolate Campylobacter jejuni and Campylobacter coli from whole chicken carcass rinse. A total of 80 whole chickens were rinsed with 400 mL of buffer peptone water. The rinsed samples were incubated with 2× blood-free modified Bolton enrichment broth for 48 h, and then streaked onto unmodified Karmali agar and modified Karmali agar supplemented with 100000 IU/L polymixin B (P-Karmali agar). The suspected colonies were finally confirmed by colony PCR. The P-Karmali agar exhibited a significantly better (P < 0.05) isolation rate than the unmodified Karmali agar (P-Karmali agar, 73.8%; unmodified Karmali agar, 33.8%). Moreover, the selectivity of the P-Karmali agar was also better (P < 0.05) than that of the other selective agar when comparing the number of contaminated plates (P-Karmali agar, 68.8%; unmodified Karmali agar, 87.5%) and growth index of competing flora (P-Karmali agar, 1.4; unmodified Karmali agar, 2.7). The improved selective agar excluded competing flora resistant to antibiotic agents in unmodified Karmali agar, increasing isolation rate and selectivity for C. jejuni and C. coli. © 2013 Institute of Food Technologists®

  9. Comparison of neck skin excision and whole carcass rinse sampling methods for determining Salmonella prevalence and E. coli counts on broiler carcasses before and after immersion chilling

    USDA-ARS?s Scientific Manuscript database

    A regulatory agency (FSIS) in the U.S. rinses whole broiler carcasses with 400 ml of 1% buffered peptone water (BPW) for Salmonella detection, while the European Union (EU) samples a 25g composited neck skin from three carcasses. The purpose of the study was to evaluate the FSIS and EU procedures fo...

  10. Microbiology of broiler carcasses and chemistry of chiller water as affected by water reuse.

    PubMed

    Northcutt, J K; Smith, D; Huezo, R I; Ingram, K D

    2008-07-01

    A study was conducted to determine the effects of treating and reusing poultry chiller water in a commercial poultry processing facility. Broiler carcasses and chiller water were obtained from a commercial processing facility which had recently installed a TOMCO Pathogen Management System to recycle water in sections 2 and 3 of two 3-compartment chillers. In this system, reused water is blended with fresh water to maintain the chiller volume. Carcasses were sampled prechill and postchill (final exit), and chiller water was sampled from the beginning and end of each of the 3 sections. Carcasses were subjected to a whole carcass rinse (WCR) in 0.1% peptone. Numbers of Escherichia coli (EC), coliforms (CF), and Campylobacter (CPY) were determined from the WCR and chiller water samples. Prevalence of Salmonella (SAL) was also determined on the WCR and chiller water samples. On average, prechill levels of bacteria recovered from rinses were 2.6, 2.9, and 2.6 log10 cfu/mL for EC, CF, and CPY, respectively. Ten out of 40 (25%) prechill carcasses were positive for SAL. After chilling, numbers of EC, CF, and CPY recovered from carcass rinses decreased by 1.5, 1.5, and 2.0 log10 cfu/mL, respectively. However, 9 out of 40 (22%) postchill carcasses were positive for SAL. When the chiller water samples were tested, counts of EC, CF, and CPY were found only in water collected from the first section of the chiller (inlet and outlet). Two of 4 water samples collected from the inlet of the first section tested positive for SAL. This study shows that fresh and reused water can be used to cool poultry in chiller systems to achieve a reduction in numbers of bacteria (EC, CF, and CPY) or equivalent prevalence (SAL) of bacteria recovered from broiler carcasses.

  11. Short term clinical effectiveness of a 0.07% cetylpyridinium chloride mouth rinse in patients undergoing fixed orthodontic appliance treatment.

    PubMed

    Pahwa, Narinder; Kumar, Atul; Gupta, Siddharth

    2011-07-01

    To test the short term clinical effectiveness of commercially available 0.07%.cetylpyridinium chloride mouth rinse in patients undergoing fixed orthodontic treatment as compared to a placebo mouth rinse and patients using toothbrush and toothpaste. Forty-five subjects for this double blind study were assigned randomly into three groups of 15 each. Gingival inflammation, plaque accumulation, and bleeding on probing, were recorded at baseline (10 days after prophylaxis), and at the end of one month in all the three groups and compared. Paired t test showed significant differences in bleeding index for pre and post treatment recordings for cetylpyridinium group. Modified gingival index showed no significant difference in the cetylpyridinium group. For plaque index significant difference was found for cetylpyridinium and control groups. Cetylpyridinium mouth rinse 0.7% was found to be effective in reducing the bleeding and plaque index scores. It was not effective in reducing the modified gingival index scores. Cetylpyridinium mouth rinse 0.07% improves the oral hygiene of orthodontic patients when used as an adjunct to normal oral hygiene measures.

  12. Short term clinical effectiveness of a 0.07% cetylpyridinium chloride mouth rinse in patients undergoing fixed orthodontic appliance treatment

    PubMed Central

    Pahwa, Narinder; Kumar, Atul; Gupta, Siddharth

    2011-01-01

    Objectives To test the short term clinical effectiveness of commercially available 0.07%.cetylpyridinium chloride mouth rinse in patients undergoing fixed orthodontic treatment as compared to a placebo mouth rinse and patients using toothbrush and toothpaste. Method Forty-five subjects for this double blind study were assigned randomly into three groups of 15 each. Gingival inflammation, plaque accumulation, and bleeding on probing, were recorded at baseline (10 days after prophylaxis), and at the end of one month in all the three groups and compared. Results Paired t test showed significant differences in bleeding index for pre and post treatment recordings for cetylpyridinium group. Modified gingival index showed no significant difference in the cetylpyridinium group. For plaque index significant difference was found for cetylpyridinium and control groups. Conclusion Cetylpyridinium mouth rinse 0.7% was found to be effective in reducing the bleeding and plaque index scores. It was not effective in reducing the modified gingival index scores. Cetylpyridinium mouth rinse 0.07% improves the oral hygiene of orthodontic patients when used as an adjunct to normal oral hygiene measures. PMID:23960507

  13. A clinical trial of the effect of a mouth-rinse prepared with Lippia sidoides Cham essential oil in dogs with mild gingival disease.

    PubMed

    Girão, V C C; Nunes-Pinheiro, D C S; Morais, S M; Sequeira, J L; Gioso, M A

    2003-05-30

    We evaluated the effect of a mouth-rinse prepared using Lippia sidoides essential oil (EO) in dogs with marginal gingivitis. German Shepherd dogs were distributed in two groups: control (control mouth-rinse) and EO (EO mouth-rinse). Both mouth-rinses were applied on the dogs' teeth every 2 days for 2 weeks. At day 0 and day 15, the scores for plaque-bacteria (P), calculus (C), gingivitis (G) and the inflammatory infiltrate (INF) were evaluated blindly. The results were analyzed by the Wilcoxon signed-rank and Mann-Whitney tests (P

  14. Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers

    PubMed Central

    Richdale, Kathryn; Mitchell, Gladys Lynn; Kinoshita, Beth T.; Lam, Dawn Y.; Wagner, Heidi; Sorbara, Luigina; Chalmers, Robin L.; Collier, Sarah A.; Cope, Jennifer R.; Rao, Maya M.; Beach, Michael J.; Yoder, Jonathan S.

    2017-01-01

    Purpose: To understand soft contact lens (SCL) and gas-permeable (GP) lens wearers' behaviors and knowledge regarding exposure of lenses to water. Methods: The Contact Lens Risk Survey (CLRS) and health behavior questions were completed online by a convenience sample of 1056 SCL and 85 GP lens wearers aged 20 to 76 years. Participants were asked about exposing their lenses to water and their understanding of risks associated with these behaviors. Chi-square analyses examined relationships between patient behaviors and perceptions. Results: GP lens wearers were more likely than SCL wearers to ever rinse or store lenses in water (rinsing: 91% GP, 31% SCL, P < 0.001; storing: 33% GP, 15% SCL P < 0.001). Among SCL wearers, men were more likely to store (24% vs. 13%, P = 0.003) or rinse (41% vs. 29%, P = 0.012) their lenses in water. Showering while wearing lenses was more common in SCL wearers (86%) than GP lens wearers (67%) (P < 0.0001). Swimming while wearing lenses was reported by 62% of SCL wearers and 48% of GP lens wearers (P = 0.027). Wearers who rinsed (SCL; P < 0.0001, GP; P = 0.11) or stored lenses in water (SCL; P < 0.0001, GP P = 0.007) reported that this behavior had little or no effect on their infection risk, compared with those who did not. Both SCL (P < 0.0001) and GP lens wearers (P < 0.0001) perceived that distilled water was safer than tap water for storing or rinsing lenses. Conclusions: Despite previously published evidence of Acanthamoeba keratitis' association with water exposure, most SCL, and nearly all GP lens wearers, regularly expose their lenses to water, with many unaware of the risk. PMID:28410356

  15. No Dose-Response Effect of Carbohydrate Mouth Rinse Concentration on 5-km Running Performance in Recreational Athletes.

    PubMed

    Clarke, Neil D; Thomas, James R; Kagka, Marion; Ramsbottom, Roger; Delextrat, Anne

    2017-03-01

    Clarke, ND, Thomas, JR, Kagka, M, Ramsbottom, R, and Delextrat, A. No dose-response effect of carbohydrate mouth rinse concentration on 5-km running performance in recreational athletes. J Strength Cond Res 31(3): 715-720, 2017-Oral carbohydrate rinsing has been demonstrated to provide beneficial effects on exercise performance of durations of up to 1 hour, albeit predominately in a laboratory setting. The aim of the present study was to investigate the effects of different concentrations of carbohydrate solution mouth rinse on 5-km running performance. Fifteen healthy men (n = 9; mean ± SD age; 42 ± 10 years; height, 177.6 ± 6.1 cm; body mass, 73.9 ± 8.9 kg) and women (n = 6; mean ± SD age, 43 ± 9 years; height, 166.5 ± 4.1 cm; body mass, 65.7 ± 6.8 kg) performed a 5-km running time trial on a track on 4 separate occasions. Immediately before starting the time trial and then after each 1 km, subjects rinsed 25 ml of 0, 3, 6, or 12% maltodextrin for 10 seconds. Mouth rinsing with 0, 3, 6, or 12% maltodextrin did not have a significant effect on the time to complete the time trial (0%, 26:34 ± 4:07 minutes:seconds; 3%, 27:17 ± 4:33 minutes:seconds; 6%, 27:05 ± 3:52 minutes:seconds; 12%, 26:47 ± 4.31 minutes:seconds; p = 0.071; (Equation is included in full-text article.)= 0.15), heart rate (p = 0.095; (Equation is included in full-text article.)= 0.16), rating of perceived exertion (p = 0.195; (Equation is included in full-text article.)= 0.11), blood glucose (p = 0.920; (Equation is included in full-text article.)= 0.01), and blood lactate concentration (p = 0.831; (Equation is included in full-text article.)= 0.02), with only nonsignificant trivial to small differences between concentrations. Results of this study suggest that carbohydrate mouth rinsing provides no ergogenic advantage over an acaloric placebo (0%) and that there is no dose-response relationship between carbohydrate solution concentration and 5-km track running performance.

  16. Modification of Karmali agar by supplementation with potassium clavulanate for the isolation of Campylobacter from chicken carcass rinses.

    PubMed

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Dong-Hyeon; Kim, Hyunsook; Choi, In-Soo; Oh, Deog-Hwan; Seo, Kun-Ho

    2014-07-01

    The detection ability and selectivity of Karmali agar was improved by supplementation of an extended-spectrum β-lactamase inhibitor, potassium clavulanate. The optimum concentration of potassium clavulanate (0.5 μg/ml) in Karmali agar was determined by inoculation of 50 Campylobacter and 30 extended-spectrum β-lactamase-producing E. coli strains onto normal and modified Karmali agar containing various concentrations of the agent. Eighty retail carcasses were rinsed with 400 ml of buffered peptone water. The rinse samples were enriched in 2 × blood-free Bolton enrichment broth at 42°C for 48 h and then were streaked onto normal and modified Karmali agar containing 0.5 μg/ml potassium clavulanate. The suspicious colonies were subcultured on Columbia blood agar and confirmed by colony PCR. In chicken carcass samples, the modified Karmali agar showed a significantly greater isolation rate than normal Karmali agar (42.5 versus 21.3%; P < 0.05). Furthermore, the selectivity of the modified Karmali agar was also significantly higher (P < 0.05) than that of the normal Karmali agar, as seen by comparison of the number of contaminated agar plates (83.8 versus 97.5%) and the growth index (1.67 versus 2.91) of the non-Campylobacter colonies.

  17. Cooking rice in excess water reduces both arsenic and enriched vitamins in the cooked grain.

    PubMed

    Gray, Patrick J; Conklin, Sean D; Todorov, Todor I; Kasko, Sasha M

    2016-01-01

    This paper reports the effects of rinsing rice and cooking it in variable amounts of water on total arsenic, inorganic arsenic, iron, cadmium, manganese, folate, thiamin and niacin in the cooked grain. We prepared multiple rice varietals both rinsed and unrinsed and with varying amounts of cooking water. Rinsing rice before cooking has a minimal effect on the arsenic (As) content of the cooked grain, but washes enriched iron, folate, thiamin and niacin from polished and parboiled rice. Cooking rice in excess water efficiently reduces the amount of As in the cooked grain. Excess water cooking reduces average inorganic As by 40% from long grain polished, 60% from parboiled and 50% from brown rice. Iron, folate, niacin and thiamin are reduced by 50-70% for enriched polished and parboiled rice, but significantly less so for brown rice, which is not enriched.

  18. Comparison between self-formulation and compounded-formulation dexamethasone mouth rinse for oral lichen planus: a pilot, randomized, cross-over trial.

    PubMed

    Hambly, Jessica L; Haywood, Alison; Hattingh, Laetitia; Nair, Raj G

    2017-08-01

    There is a lack of appropriate, commercially-available topical corticosteroid formulations for use in oral lichen planus (OLP) and oral lichenoid reaction. Current therapy includes crushing a dexamethasone tablet and mixing it with water for use as a mouth rinse. This formulation is unpleasant esthetically and to use in the mouth, as it is a bitter and gritty suspension, resulting in poor compliance. Thus, the present study was designed to formulate and pilot an effective, esthetically-pleasing formulation. A single-blinded, cross-over trial was designed with two treatment arms. Patients were monitored for 7 weeks. Quantitative and qualitative data was assessed using VAS, numeric pain scales, the Treatment Satisfaction Questionnaire for Medication-9, and thematic analysis to determine primary patient-reported outcomes, including satisfaction, compliance, quality of life, and symptom relief. Nine patients completed the pilot trial. Data analysis revealed the new compounded formulation to be superior to existing therapy due to its convenience, positive contribution to compliance, patient-perceived faster onset of action, and improved symptom relief. Topical dexamethasone is useful in the treatment of OLP. When carefully formulated into a compounded mouth rinse, it improves patient outcomes. © 2016 John Wiley & Sons Australia, Ltd.

  19. Treatment of oral malodor and periodontal disease using an antibiotic rinse.

    PubMed

    Southward, Ken; Bosy, Anne

    2013-07-01

    The purpose of this study was to determine the effectiveness of an antibiotic rinse preparation, containing metronidazole and nystatin, in decreasing oral malodor and periodontal disease for individuals whose chief complaint was halitosis. This topical approach to oral biofilm control, by proactively managing the most pathogenic bacteria, differs from the traditional approach of reactively treating the symptoms by attempting to reduce all oral bacteria. The late Dr. Loesche, University of Michigan, School of Dentistry, had previously described these different paradigms as the specific plaque hypothesis and the non-specific plaque hypothesis, respectively. Patients in this study were measured before and after treatment for volatile sulphur compounds using a portable sulphide monitor, a digital gas chromatograph, and organoleptic assessment. The presence of periodontal disease was determined by 6-point periodontal probing, to assess pocket depth and bleeding points. Of the 1000 patient charts sent electronically to the University of Michigan for analysis, 649 participants were selected based on complete pre- and post-treatment data, and statistically analyzed by a statistician, who was an expert in case study analysis. The post-treatment reduction of oral malodor was 80% (P = 0.0001). The difference in bleeding points pre- and post-treatment was 87% (P = 0.0001). There was a decrease in the number of teeth with 6 and 7 mm pockets by 76% and teeth with 5 mm pockets decreased by 84% (P = 0.0001). Treatment with the antibiotic rinse had a positive change in the periodontal status and breath odor of these patients. These data indicate that there is considerable advantage to the use of topical antibiotic rinses. A substantial decrease in both halitosis and periodontal disease markers can be achieved without the risk of the systemic effects of an oral antibiotic.

  20. Investigation Into The Effectiveness of The JLAB High Pressure Rinse System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John Mammosser; Timothy Rothgeb; Tong Wang

    2003-05-01

    As part of a study to reduce field emission in Superconducting radio frequency cavities, an investigation into the effectiveness of the Jefferson Lab's High Pressure Rinse (HPR) system is underway. This paper describes discoveries from this investigation, the procedural changes made during this investigation, current vertical test results and further plans for improvements and monitoring.

  1. Preliminary Test Results from 650 MHz Single Cell Medium Beta Cavities for Project X

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marhauser, Frank; Kneisel, Peter; Burrill, Andrew

    We have fabricated two single cell 650 MHz {beta}=0.61 cavities of a JLab design, which possibly can be used for the proposed Project X proton linac application. Both cavities were manufactured at JLab from RRR>250 niobium sheet of 4 mm thickness using standard techniques such as deep drawing, electron beam welding, buffered chemical polishing, hydrogen degassing heat treatment, high pressure ultrapure water rinsing and clean room assembly. Initially cavity no. 1 was -- after final surface treatment by buffered chemical polishing (BCP) -- measured without any provisions for stiffening. As expected, the pressure sensitivity and the Lorentz Force detuning coefficientsmore » were relatively high; however, the RF performance was very encouraging: the cavity exhibited a Q-value > 10{sup 11} at 1.6K, corresponding to a residual resistance of < 1.5 n{Omega} The initial gradient was limited to E{sub acc} ~ 18 MV/m, limited by field emission. In a subsequent test, the cavity was re-rinsed and stiffened up, resulting in a somewhat improved mechanical behavior, but no improvement in rf performance. The second cavity was also tested twice, before and after low temperature baking. The results from all tests are reported in this contribution.« less

  2. Effects of Compounded Stanford Modified Oral Rinse (MucoLox) on the Survival and Migration of Oral Keratinocytes and Fibroblasts: Implications for Wound Healing.

    PubMed

    Song, Guiyun; Banov, Daniel; Bassani, August S

    2018-01-01

    Several oral rinses are commercially available to alleviate the symptoms of oral mucositis. Prolonged retention of active pharmaceutical ingredients in the oral cavity is a major problem. In this study, we modified the Stanford oral rinse by including a proprietary mucoadhesive polymer called MucoLox, which we hypothesized would improve active pharmaceutical ingredient mucoadhesion. Characterization of this newly compounded oral rinse showed absence of cytotoxicity in human oral keratinocyte and fibroblast cell lines. The compounded formulation significantly stimulated the migration of these two cell lines in Oris Cell Migration Assay plates, better than the reference commercial product Magic mouthwash. Based on this in vitro study, the new Stanford modified oral rinse with MucoLox is safe and may promote healing of oral mucositis. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  3. Method for simultaneous recovery of hydrogen from water and from hydrocarbons

    DOEpatents

    Willms, R. Scott

    1996-01-01

    Method for simultaneous recovery of hydrogen and hydrogen isotopes from water and from hydrocarbons. A palladium membrane, when utilized in cooperation with a nickel catalyst in a reactor, has been found to drive reactions such as water gas shift, steam reforming and methane cracking to substantial completion by removing the product hydrogen from the reacting mixture. In addition, ultrapure hydrogen is produced, thereby eliminating the need for an additional processing step.

  4. Study on Formation of Plasma Nanobubbles in Water

    NASA Astrophysics Data System (ADS)

    Sato, Takehiko; Nakatani, Tatsuyuki; Miyahara, Takashi; Ochiai, Shiroh; Oizumi, Masanobu; Fujita, Hidemasa; Miyazaki, Takamichi

    2015-12-01

    Nanobubbles of less than 400 nm in diameter were formed by plasma in pure water. Pre-breakdown plasma termed streamer discharges, generated gas channels shaped like fine dendritic coral leading to the formation of small bubbles. Nanobubbles were visualized by an optical microscope and measured by dynamic laser scattering. However, it is necessary to verify that these nanobubbles are gas bubbles, not solid, because contamination such as platinum particles and organic compounds from electrode and residue in ultrapure water were also observed.

  5. Enumeration of Salmonella and Campylobacter spp. in environmental farm samples and processing plant carcass rinses from commercial broiler chicken flocks.

    PubMed

    Berghaus, Roy D; Thayer, Stephan G; Law, Bibiana F; Mild, Rita M; Hofacre, Charles L; Singer, Randall S

    2013-07-01

    A prospective cohort study was performed to evaluate the prevalences and loads of Salmonella and Campylobacter spp. in farm and processing plant samples collected from 55 commercial broiler chicken flocks. Environmental samples were collected from broiler houses within 48 h before slaughter, and carcass rinses were performed on birds from the same flocks at 4 different stages of processing. Salmonella was detected in farm samples of 50 (90.9%) flocks and in processing samples of 52 (94.5%) flocks. Campylobacter was detected in farm samples of 35 (63.6%) flocks and in processing samples of 48 (87.3%) flocks. There was a significant positive relationship between environmental farm samples and processing plant carcass rinses with respect to both Salmonella and Campylobacter prevalences and loads. Campylobacter loads were significantly higher than Salmonella loads, and the correlations between samples collected from the same flocks were higher for Campylobacter than they were for Salmonella. Boot socks were the most sensitive sample type for detection of Salmonella on the farm, whereas litter samples had the strongest association with Salmonella loads in pre- and postchill carcass rinses. Boot socks, drag swabs, and fecal samples all had similar sensitivities for detecting Campylobacter on the farm, and all were more strongly associated with Campylobacter loads in carcass rinses than were litter samples. Farm samples explained a greater proportion of the variability in carcass rinse prevalences and loads for Campylobacter than they did for Salmonella. Salmonella and Campylobacter prevalences and loads both decreased significantly as birds progressed through the processing plant.

  6. Enumeration of Salmonella and Campylobacter spp. in Environmental Farm Samples and Processing Plant Carcass Rinses from Commercial Broiler Chicken Flocks

    PubMed Central

    Thayer, Stephan G.; Law, Bibiana F.; Mild, Rita M.; Hofacre, Charles L.; Singer, Randall S.

    2013-01-01

    A prospective cohort study was performed to evaluate the prevalences and loads of Salmonella and Campylobacter spp. in farm and processing plant samples collected from 55 commercial broiler chicken flocks. Environmental samples were collected from broiler houses within 48 h before slaughter, and carcass rinses were performed on birds from the same flocks at 4 different stages of processing. Salmonella was detected in farm samples of 50 (90.9%) flocks and in processing samples of 52 (94.5%) flocks. Campylobacter was detected in farm samples of 35 (63.6%) flocks and in processing samples of 48 (87.3%) flocks. There was a significant positive relationship between environmental farm samples and processing plant carcass rinses with respect to both Salmonella and Campylobacter prevalences and loads. Campylobacter loads were significantly higher than Salmonella loads, and the correlations between samples collected from the same flocks were higher for Campylobacter than they were for Salmonella. Boot socks were the most sensitive sample type for detection of Salmonella on the farm, whereas litter samples had the strongest association with Salmonella loads in pre- and postchill carcass rinses. Boot socks, drag swabs, and fecal samples all had similar sensitivities for detecting Campylobacter on the farm, and all were more strongly associated with Campylobacter loads in carcass rinses than were litter samples. Farm samples explained a greater proportion of the variability in carcass rinse prevalences and loads for Campylobacter than they did for Salmonella. Salmonella and Campylobacter prevalences and loads both decreased significantly as birds progressed through the processing plant. PMID:23624481

  7. Comparative effect of fluoride, essential oil and chlorhexidine mouth rinses on dental plaque and gingivitis in patients with and without dental caries: a randomized controlled trial.

    PubMed

    Charugundla, B R; Anjum, S; Mocherla, M

    2015-05-01

    The objective of this study was to compare the effectiveness of fluoride, essential oil (EO) and chlorhexidine (CHX)-containing mouth rinses on dental plaque and gingivitis and to compare their relative efficacy in patients with and without dental caries. A randomized, controlled, double- blind, crossover clinical trial was conducted for a period of 8 weeks. Thiry-six qualifying subjects, aged 12-44 years, were included in the study. Subjects were divided into caries and caries-free groups and were randomly assigned to one of the following mouth rinse groups: fluoride; EO; CHX and saline as negative control. Subjects used their respective mouth rinse for a period of 7-days each with 1-week wash-out periods. Primary efficacy variables were Quigley-Hein plaque index (PI) and Loe and Silness gingival index. Fluoride and CHX mouth rinses showed significant reduction in plaque after use of mouth rinses (P < 0.05). However, no significant differences were observed with respect to each other in reducing gingivitis (P > 0.05). Further significant differences were found in reducing plaque and gingivitis in caries-free subjects in comparison to those with caries (P < 0.05). All the three mouth rinses significantly reduced plaque accumulation and gingivitis especially in caries-free subjects in comparison to those with caries, and amongst the three, fluoride and CHX proved to be more effective than EO mouth rinse. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Parabens abatement from surface waters by electrochemical advanced oxidation with boron doped diamond anodes.

    PubMed

    Domínguez, Joaquín R; Muñoz-Peña, Maria J; González, Teresa; Palo, Patricia; Cuerda-Correa, Eduardo M

    2016-10-01

    The removal efficiency of four commonly-used parabens by electrochemical advanced oxidation with boron-doped diamond anodes in two different aqueous matrices, namely ultrapure water and surface water from the Guadiana River, has been analyzed. Response surface methodology and a factorial, composite, central, orthogonal, and rotatable (FCCOR) statistical design of experiments have been used to optimize the process. The experimental results clearly show that the initial concentration of pollutants is the factor that influences the removal efficiency in a more remarkable manner in both aqueous matrices. As a rule, as the initial concentration of parabens increases, the removal efficiency decreases. The current density also affects the removal efficiency in a statistically significant manner in both aqueous matrices. In the water river aqueous matrix, a noticeable synergistic effect on the removal efficiency has been observed, probably due to the presence of chloride ions that increase the conductivity of the solution and contribute to the generation of strong secondary oxidant species such as chlorine or HClO/ClO - . The use of a statistical design of experiments made it possible to determine the optimal conditions necessary to achieve total removal of the four parabens in ultrapure and river water aqueous matrices.

  9. Clinical efficacy analysis of the mouth rinsing with pomegranate and chamomile plant extracts in the gingival bleeding reduction.

    PubMed

    Batista, Ana Luzia Araújo; Lins, Ruthineia Diógenes Alves Uchôa; de Souza Coelho, Renata; do Nascimento Barbosa, Danielle; Moura Belém, Nayara; Alves Celestino, Frayni Josley

    2014-02-01

    Medicinal plants represent important therapeutic resources to health restoration, including the use of herbal products in the mouth conditions treatment. A randomized controlled clinical trial was performed in order to evaluate the effectiveness of mouth rinse with pomegranate and chamomile plant extracts, against chlorhexidine 0.12% in the gingiva bleeding condition. The mouth rinses with the herbal products were effective for this case, showing thus, antimicrobial and anti-inflammatory properties similar to that of chlorhexidine 0.12%. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Transcriptome analysis of seed dormancy after rinsing and chilling in ornamental peaches (Prunus persica (L.) Batsch).

    PubMed

    Kanjana, Worarad; Suzuki, Tomohiro; Ishii, Kazuo; Kozaki, Toshinori; Iigo, Masayuki; Yamane, Kenji

    2016-08-08

    Ornamental peaches cv. 'Yaguchi' (Prunus persica (L.) Batsch) can be propagated via seeds. The establishment of efficient seed treatments for early germination and seedling growth is required to shorten nursery and breeding periods. It is important, therefore, to identify potential candidate genes responsible for the effects of rinsing and chilling on seed germination. We hypothesized that longer rinsing combined with chilling of seeds can alter the genes expression in related to dormancy and then raise the germination rate in the peach. To date, most molecular studies in peaches have involved structural genomics, and few transcriptome studies of seed germination have been conducted. In this study, we investigated the function of key seed dormancy-related genes using next-generation sequencing to profile the transcriptomes involved in seed dormancy in peaches. De novo assembly and analysis of the transcriptome identified differentially expressed and unique genes present in this fruit. De novo RNA-sequencing of peach was performed using the Illumina Miseq 2000 system. Paired-end sequence from mRNAs generated high quality sequence reads (9,049,964, 10,026,362 and 10,101,918 reads) from 'Yaguchi' peach seeds before rinsed (BR) and after rinsed for 2 or 7 days with a chilling period of 4 weeks (termed 2D4W and 7D4W), respectively. The germination rate of 7D4W was significantly higher than that of 2D4W. In total, we obtained 51,366 unique sequences. Differential expression analysis identified 7752, 8469 and 506 differentially expressed genes from BR vs 2D4W, BR vs 7D4W and 2D4W vs 7D4W libraries respectively, filtered based on p-value and an adjusted false discovery rate of less than 0.05. This study identified genes associated with the rinsing and chilling process that included those associated with phytohormones, the stress response and transcription factors. 7D4W treatment downregulated genes involved in ABA synthesis, catabolism and signaling pathways, which

  11. Running Performance with Nutritive and Non-Nutritive Sweetened Mouth Rinses

    PubMed Central

    Hawkins, Keely H.; Krishnan, Sridevi; Ringos, Lara; Garcia, Vanessa; Cooper, Jamie A.

    2017-01-01

    Mouth rinsing (MR) with carbohydrate during exercise has been shown to act as an ergogenic aid. Purpose To investigate if nutritive or nonnutritive sweetened MR affect exercise performance, and to assess the influence of sweetness intensity on endurance performance during a time-trial (TT). Methods This randomized, single blinded study had 4 treatment conditions. 16 subjects (9 men, 7 women) completed a 12.8km TT four different times. During each TT, subjects MR and expectorated a different solution at time 0 and every 12.5% of the TT. The 4 MR solutions were: sucrose (S) (sweet taste and provides energy of 4 kcals/g), a lower intensity sucralose (S1:1) (artificial sweetener that provides no energy but tastes sweet), a higher intensity sucralose (S100:1), and water as control (C). Completion times for each TT, heart rate (HR) and ratings of perceived exertion (RPE) were also recorded. Results Completion time for S was faster than C (1:03:47±00:02:17 vs. 1:06:56±00:02:18; p<0.001, respectively), and showed a trend to be faster vs. S100:1 (1:03:47±00:02:17 vs. 1:05:38±00:02:12; p=0.07, respectively). No other TT differences were found. Average HR showed a trend to be higher for S vs. C (p=0.08). There only differences in average or max RPE was for higher max RPE in C vs. S1:1 (p=0.02). Conclusion A sweet tasting MR did improve endurance performance compared to water in a significant manner (avg. 4.5% improvement; 3+ min.); however, the presence of energy in the sweet MR appeared necessary since the artificial sweeteners did not improve performance more than water alone. PMID:28095077

  12. Safety and Efficacy of a Mouth-Rinse with Granulocyte Colony Stimulating Factor in Patients with Chemotherapy-Induced Oral Mucositis.

    PubMed

    Wang, Lin; Huang, Xin-En; Ji, Zhu-Qing; Liu, Meng-Yan; Qian, Ting; Li, Li

    2016-01-01

    To assess the safety and effectiveness of a mouth-rinse with G-CSF (JiSaiXin, produced by NCPC Biotechnology Co., Ltd) in treating patients with chemotherapy-induced oral mucositis (CIM). A consecutive cohort of patients with advanced cancers and CIM were treated with mouth-rinse G-CSF. All chemotherapy for patients with advanced cancers was adopted from regimens suggested by NCCN guidelines. The mouth-rinse with G-CSF at a dose of 150-300ug plus 100ml-500ml normal saline was started from the time of oral mucositis was confirmed and continuously used for at least 7 days as one course. After at least two courses of treatment, safety and efficacy were evaluated. There were 7 female and 7 male patients with advanced cancer and CIM recruited into this study, including 5 with colorectal, 2 with lung, 1 patient with gastric, 1 with cervical and 1 with pancreatic cancer, as well as 2 patients with diffuse large B cell lymphomas, 1 with nasopharyngeal and 1 with gastric cancer. The median age was 57 (41-79) years. Grade 1 to 2 myelosuppression was observed in 3/14 patients, and Grade 4 myelosuppression in 1/14. Adverse effects on the gastrointestinal tract were documented in 5/14 patients, and were Grade 1 to Grade 3. No treatment related death was documented. Regarding CIM, the median response time to mouth rinse of G-CSF was 2 (1-5) days, and all patients with CIM demonstrated a positive response. Mouth-rinse with G-CSF proved to be safe and effective in treating patients with advanced cancers and CIM. However, further randomized controlled studies should be conducted to clarify the effectiveness of this treatment with other lesions.

  13. Rapid and Quantitative Detection of Hepatitis A Virus from Green Onion and Strawberry Rinses by Use of Real-Time Reverse Transcription-PCR

    PubMed Central

    Shan, X. C.; Wolffs, P.; Griffiths, M. W.

    2005-01-01

    In this study, an immunomagnetic capture method and a real-time reverse transcription-PCR assay were used to quantify hepatitis A virus (HAV) in green onion and strawberry rinses. This combined protocol detected as low as 0.5 PFU HAV in produce rinses and concentrated HAV levels up to 20-fold. PMID:16151164

  14. Cytocompatibility evaluation of gum Arabic-coated ultra-pure boron nitride nanotubes on human cells.

    PubMed

    Ciofani, Gianni; Del Turco, Serena; Rocca, Antonella; de Vito, Giuseppe; Cappello, Valentina; Yamaguchi, Maho; Li, Xia; Mazzolai, Barbara; Basta, Giuseppina; Gemmi, Mauro; Piazza, Vincenzo; Golberg, Dmitri; Mattoli, Virgilio

    2014-05-01

    Boron nitride nanotubes (BNNTs) are tubular nanoparticles with a structure analogous to that of carbon nanotubes, but with B and N atoms that completely replace the C atoms. Many favorable results indicate BNNTs as safe nanomaterials; however, important concerns have recently been raised about ultra-pure, long (~10 µm) BNNTs tested on several cell types. Here, we propose additional experiments with the same BNNTs, but shortened (~1.5 µm) with a homogenization/sonication treatment that allows for their dispersion in gum Arabic aqueous solutions. Obtained BNNTs are tested on human endothelial and neuron-like cells with several independent biocompatibility assays. Moreover, for the first time, their strong sum-frequency generation signal is exploited to assess the cellular uptake. Our data demonstrate no toxic effects up to concentrations of 20 µg/ml, once more confirming biosafety of BNNTs, and again highlighting that nanoparticle aspect ratio plays a key role in the biocompatibility evaluation.

  15. A comparison of dioctahedral smectite and iodine glycerin cream with topical mouth rinse in treatment of chemotherapy induced oral mucositis: a pilot study.

    PubMed

    Lin, Jin-Xiang; Fan, Zu-Yan; Lin, Qu; Wu, Dong-Hao; Wu, Xiang-Yuan; Chen, Yan-Ru; Fang, Heng-Ying; Wu, Dong-Bing; Wen, Jing-Yun; Dong, Min; Ma, Xiao-Kun; Wan, Xiang-Bo

    2015-04-01

    To compare the efficacy of dioctahedral smectite and iodine glycerin (DSIG) cream with topical mouth rinse (composed of saline, gentamicin and Vitamin B12) in treatment of chemotherapy induced oral mucositis (OM). A total of 130 intensive chemotherapy or stem cells transplantation induced OM patients were recruited. Among these patients, 67 patients received topical mouth rinse and 63 patients received DSIG cream treatment. The OM would be treated on the OM appearance and sustained for 5 days. OM severity was measured daily using The American Oncology Nursing Society recommended Oral Assessment Guideline (OAG) score system. Compared with topical mouth rinse treatment, a significant lower OAG score was observed in DSIG cream treated patients. Specifically, the OAG scores were respectively 12.1 ± 1.1, 12.0 ± 1.2, 11.3 ± 1.3 and 10.4 ± 1.3 from day 2 to day 5 in topical mouth rinse treatment subgroup. Correspondingly, the OAG scores were respectively 10.2 ± 1.0, 9.3 ± 0.9, 8.5 ± 0.6 and 8.0 ± 0.2 for DSIG cream treatment subset (all P < 0.05). Importantly, compared with topical mouth rinse treatment, the DSIG cream significantly shortened OM repair time (4.68 ± 0.98 vs. 8.76 ± 1.80 days, P < 0.001). After 5 days treatment, 54 patients (85.7%) obtained complete regression with an OAG score ≤8, and 7 patients (11.1%) had partial regression with an OAG score of 9-10 in DSIG cream treatment subgroup. However, only 2 patients (3.0%) obtained completed regression and 32 patients (47.8%) had partial regression in topical mouth rinse treatment cohort. Moreover, no serious side-effect was observed in both cohorts. Compared with topical mouth rinse, DSIG cream significantly lowered the OAG score and shortened OM duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Fluoride rinse effect on retention of CaF2 formed on enamel/dentine by fluoride application.

    PubMed

    Falcão, Amanda; Masson, Nadia; Leitão, Tarcísio Jorge; Botelho, Juliana Nunes; Ferreira-Nóbilo, Naiara de Paula; Tabchoury, Cínthia Pereira Machado; Tenuta, Livia Maria Andaló; Cury, Jaime Aparecido

    2016-01-01

    Calcium fluoride-like materials ("CaF2") formed on dental surfaces after professional fluoride application are unstable in the oral environment but can be retained longer with a daily NaF mouthrinse. We tested the effect of twice daily 0.05% NaF rinses on the retention of "CaF2" formed on enamel and dentine after applying acidulated phosphate fluoride (APF). "CaF2" formed on enamel/dentine by APF application significantly decreased after exposure to artificial saliva and the 0.05% NaF rinse was ineffective to avoid this reduction. These findings suggest that the combination of APF and 0.05% NaF is not clinically relevant, either for caries or dental hypersensitivity.

  17. Self-etching aspects of a three-step etch-and-rinse adhesive.

    PubMed

    Bahillo, Jose; Roig, Miguel; Bortolotto, Tissiana; Krejci, Ivo

    2013-11-01

    The purpose of this study is to assess the marginal adaptation of cavities restored with a three-step etch-and-rinse adhesive, OptiBond FL (OFL) under different application protocols. Twenty-four class V cavities were prepared with half of the margins located in enamel and half in dentin. Cavities were restored with OFL and a microhybrid resin composite (Clearfil AP-X). Three groups (n = 8) that differed in the etching technique were tested with thermomechanical loading, and specimens were subjected to quantitative marginal analysis before and after loading. Micromorphology of etching patters on enamel and dentin were observed with SEM. Data was evaluated with Kruskal-Wallis and Bonferroni post hoc test. Significantly lower percent CM (46.9 ± 19.5) were found after loading on enamel in group 3 compared to group 1 (96.5 ± 5.1) and group 2 (93.1 ± 8.1). However, no significant differences (p = 0.30) were observed on dentin margins. Etching enamel with phosphoric acid but avoiding etching dentin before the application of OFL, optimal marginal adaptation could be obtained, evidencing a self-etching primer effect. A reliable adhesive interface was attained with the application of the three-step etch-and-rinse OFL adhesive with a selective enamel etching, representing an advantage on restoring deep cavities.

  18. After-rinsing hair growth promotion of minoxidil-containing amino alpha-cyclodextrins.

    PubMed

    Kim, Jin-Chul; Kim, Myoung-Dong

    2007-12-01

    Triamino alpha-cyclodextrin (CD) was synthesized and the inclusion complex with Minoxidil (MXD) was prepared. alpha-CD was azidated by modifying the 6-hydroxylmethyl CD rim with sodium azide. Then, mono-, di-, tri-, and tetra-azidocyclodextrins were separated by a flash column chromatography and reduced to the corresponding amines by hydrogenation with Pd/C. The substantivities of MXD included in either 2-hydroxypropyl alpha-CD (HP alpha-CD) or triamino alpha-CD were evaluated in vitro using hairless mice skins. After applying the preparations onto the skin and rinsing it, the amount of the drug left on the skin was determined using high-performance liquid chromatography (HPLC). It was the highest when the drug was included in triamino alpha-CD. The electrostatic interaction between the protonated amino CD and the negatively charged skin would be responsible for the relatively high substantivity. The in vivo hair growth promotion effect of each preparation was investigated, where the sample application onto the clipped backs of female mice (C57BL6) and the subsequent rinsing of the backs were done once a day for 30 days. Only MXD in triamino alpha-CD had hair growth promotion effect, possibly due to the significant substantivity.

  19. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

    PubMed Central

    Geerts, Sabine; Bolette, Amandine; Seidel, Laurence; Guéders, Audrey

    2012-01-01

    Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Multipurpose (SBMP), a 3-step Etch and Rinse adhesive, Adper Scotchbond 1 XT (SB1), a 2-step Etch and Rinse adhesive, AdheSE One (ADSE-1), a 1-step Self-Etch adhesive, and AdheSE (ADSE), a 2-step Self-Etch adhesive. Teeth were thermocycled and immersed in 50% silver nitrate solution. When both interfaces were considered, SBMP has exhibited significantly less microleakage than other adhesive systems (resp., for SB1, ADSE-1 and ADSE, P = 0.0007, P < 0.0001 and P < 0.0001). When enamel and dentin interfaces were evaluated separately, (1) for the Self-Etch adhesives, microleakage was found greater at enamel than at dentin interfaces (for ADSE, P = 0.024 and for ADSE-1, P < 0.0001); (2) for the Etch and Rinse adhesive systems, there was no significant difference between enamel and dentin interfaces; (3) SBMP was found significantly better than other adhesives both at enamel and dentin interfaces. In our experiment Etch and Rinse adhesives remain better than Self-Etch adhesives at enamel interface. In addition, there was no statistical difference between 1-step (ADSE-1) and 2-step (ADSE) Self-Etch adhesives. PMID:22675358

  20. Rinsing paired-agent model (RPAM) to quantify cell-surface receptor concentrations in topical staining applications of thick tissues

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochun; Wang, Yu; Xiang, Jialing; Liu, Jonathan T. C.; Tichauer, Kenneth M.

    2017-06-01

    Conventional molecular assessment of tissue through histology, if adapted to fresh thicker samples, has the potential to enhance cancer detection in surgical margins and monitoring of 3D cell culture molecular environments. However, in thicker samples, substantial background staining is common despite repeated rinsing, which can significantly reduce image contrast. Recently, ‘paired-agent’ methods—which employ co-administration of a control (untargeted) imaging agent—have been applied to thick-sample staining applications to account for background staining. To date, these methods have included (1) a simple ratiometric method that is relatively insensitive to noise in the data but has accuracy that is dependent on the staining protocol and the characteristics of the sample; and (2) a complex paired-agent kinetic modeling method that is more accurate but is more noise-sensitive and requires a precise serial rinsing protocol. Here, a new simplified mathematical model—the rinsing paired-agent model (RPAM)—is derived and tested that offers a good balance between the previous models, is adaptable to arbitrary rinsing-imaging protocols, and does not require calibration of the imaging system. RPAM is evaluated against previous models and is validated by comparison to estimated concentrations of targeted biomarkers on the surface of 3D cell culture and tumor xenograft models. This work supports the use of RPAM as a preferable model to quantitatively analyze targeted biomarker concentrations in topically stained thick tissues, as it was found to match the accuracy of the complex paired-agent kinetic model while retaining the low noise-sensitivity characteristics of the ratiometric method.

  1. Effective Reuse of Electroplating Rinse Wastewater by Combining PAC with H2O2/UV Process.

    PubMed

    Yen, Hsing Yuan; Kang, Shyh-Fang; Lin, Chen Pei

    2015-04-01

    This study evaluated the performance of treating electroplating rinse wastewater by powder activated carbon (PAC) adsorption, H2O2/UV oxidation, and their combination to remove organic compounds and heavy metals. The results showed that neither the process of PAC adsorption nor H2O2/UV oxidation could reduce COD to 100 mg/L, as enforced by the Taiwan Environmental Protection Agency. On the other hand, the water sample treated by the combined approach of using PAC (5 g/L) pre-adsorption and H2O2/UV post-oxidation (UV of 64 W, H2O2 of 100 mg/L, oxidation time of 90 min), COD and DOC were reduced to 8.2 mg/L and 3.8 mg/L, respectively. Also, the combined approach reduced heavy metals to meet the effluent standards and to satisfy the in-house water reuse criteria for the electroplating factory. The reaction constant analysis indicated that the reaction proceeded much more rapidly for the combined process. Hence, it is a more efficient, economic and environmentally friendly process.

  2. Adsorption of selected emerging contaminants onto PAC and GAC: Equilibrium isotherms, kinetics, and effect of the water matrix.

    PubMed

    Real, Francisco J; Benitez, F Javier; Acero, Juan L; Casas, Francisco

    2017-07-03

    The removal of three emerging contaminants (ECs) (amitriptyline hydrochloride (AH), methyl salicylate (MS) and 2-phenoxyethanol (PE)) dissolved in several water matrices by means of their adsorption onto powdered activated carbon (PAC) and granular activated carbon (GAC) has been investigated. When dissolved in ultrapure water, adsorption of the ECs followed the trend of AH > MS > PE, with a positive effect of the adsorbent dose. According to the analysis of the adsorption isotherms and adsorption kinetics, PAC showed strongly higher adsorption efficiency in both capacity and velocity of the adsorption, in agreement with its higher mesoporosity. Equilibrium isotherm data were fitted by Langmuir and Freundlich models. Pseudo-second order kinetics modeled very successfully the adsorption process. Finally, the effect of the presence of dissolved organic matter (DOM) in the water matrices (ultrapure water, surface water and two effluents from wastewater treatment plants) on the adsorption of the selected ECs onto PAC was established, as well as its performance on the removal of water quality parameters. Results show a negative effect of the DOM content on the adsorption efficiency. Over 50% of organic matter was removed with high PAC doses, revealing that adsorption onto PAC is an effective technology to remove both micro-pollutants and DOM from water matrices.

  3. Water purification using organic salts

    DOEpatents

    Currier, Robert P.

    2004-11-23

    Water purification using organic salts. Feed water is mixed with at least one organic salt at a temperature sufficiently low to form organic salt hydrate crystals and brine. The crystals are separated from the brine, rinsed, and melted to form an aqueous solution of organic salt. Some of the water is removed from the aqueous organic salt solution. The purified water is collected, and the remaining more concentrated aqueous organic salt solution is reused.

  4. The Clinical Effectiveness of Post-Brushing Rinsing in Reducing Plaque and Gingivitis: A Systematic Review

    PubMed Central

    Patthi, Basavaraj; Singla, Ashish; Gupta, Ritu; Jankiram, Chandrasheker; Kumar, Jishnu Krishna; Vashishtha, Vaibhav; Malhi, Ravneet

    2016-01-01

    Introduction Dental plaque is the major etiological factor associated with the development of gingivitis. Hence, maintenance of oral hygiene is very essential. Aim To systematically review the literature on the effects of a post toothbrushing rinsing on plaque and parameters of gingival inflammation. Materials and Methods A literature review was performed in PubMed Central and Cochrane library, embase, google scholar were searched up to February 2015 to identify appropriate studies. The primary outcome measure was plaque and gingival inflammation reduction. Results Out of the total 56 titles appeared, 08articles fulfilled the criteria and were selected for the review. One article which was hand searched and one article which was through e-mail was included. A statistically significant reduction in overall plaque and gingivitis was noted when different mouth rinses were compared to the control (p<0.05). It was seen that chlorhexidine is the best antiplaque and antigingivitis agent but due to its side effects after continuous use, was not indicated for long term use. Probiotic was superior to chlorhexidine in terms of reduction of gingival inflammation. Conclusion There are relatively few studies evaluating the association between post toothbrushing rinsing and gingivitis. A clear effect was observed, indicating that different mouthrinses (chlorhexidine, probiotic, herbal, essential oil mouthrinse) when used as an adjunct to mechanical means of oral hygiene, provides an additional benefit with regard to plaque and gingivitis reduction as compared to a placebo or control. PMID:27437376

  5. A randomized clinical trial in subjects with dry mouth evaluating subjective perceptions of an experimental oral gel, an oral rinse and a mouth spray compared to water.

    PubMed

    Jose, Anto; Siddiqi, Muhammad; Cronin, Matthew; DiLauro, Thomas S; Bosma, Mary Lynn

    2016-02-01

    This multicenter, randomized, parallel group study analyzed the effectiveness of an experimental oral gel, a commercially available oral rinse and a commercially available mouth spray versus water alone at relieving self-reported symptoms of dry mouth over a 28-day home use treatment period. The effects of the study treatments on dry mouth-related quality of life (QoL) were also investigated. Eligible subjects were stratified by dry mouth severity (mild, moderate or severe) and randomized to receive one of the study treatments. Prior to first use they completed a questionnaire designed to assess their baseline dry mouth-related QoL. Following first use and on Day 8 (2 hours post-treatment only) and Day 29, subjects completed the modified Product Performance and Attributes Questionnaire (PPAQ) I at 0.5, 1, 2 and 4 hours post-treatment. Subjects further assessed treatment performance using the PPAQ II questionnaire on Days 8 and 29 and the dry mouth-related QoL questionnaire on Day 29. In 396 randomized subjects almost all comparisons of responses to PPAQ I, including those for the primary endpoint (response to PPAQ I Question 1 'Relieving the discomfort of dry mouth' after 2 hours on Day 29), were statistically significant in favor of active treatment groups versus water (P < 0.05). All comparisons of responses to PPAQ II on Days 8 and 29 were statistically significant in favor of active treatments versus water (P < 0.05). Moreover, nearly all comparisons for dry mouth-related QoL scores on Day 29 were statistically significant in favor of the active treatments versus water. All the dry mouth management strategies in this trial were well tolerated.

  6. Comparison of a wipe method with and without a rinse to recover wall losses in closed face 37-mm cassettes used for sampling lead dust particulates

    PubMed Central

    Ceballos, Diana; King, Bradley; Beaucham, Catherine; Brueck, Scott E.

    2015-01-01

    Closed-face 37-millimeter (mm) polystyrene cassettes are often used for exposure monitoring of metal particulates. Several methods have been proposed to account for the wall loss in air sampling cassettes, including rinsing, wiping, within-cassette dissolution, and an internal capsule fused to the filter that could be digested with the filter. Until internal capsules replace filters, other methods for assessing wall losses may be considered. To determine if rinsing and wiping or wiping alone is adequate to determine wall losses on cassettes, we collected 54 full-shift area air samples at a battery recycling facility. We collected six replicate samples at three locations within the facility for 3 consecutive days. The wall losses of three replicate cassettes from each day-location were analyzed following a rinse and two consecutive wipes. The wall losses of the other three replicates from each day-location were analyzed following two consecutive wipes only. Mixed-cellulose ester membrane filter, rinse, and wipes were analyzed separately following NIOSH Method 7303. We found an average of 29% (range: 8%–54%) recovered lead from the cassette walls for all samples. We also found that rinsing prior to wiping the interior cassette walls did not substantially improve recovery of wall losses compared to wiping alone. A rinse plus one wipe recovered on average 23% (range: 13%–33%) of the lead, while one wipe alone recovered on average 21% (range: 16%–22%). Similarly we determined that a second wipe did not provide substantial additional recovery of lead (average: 4%, range: 0.4%–19%) compared to the first wipe disregarding the rinse (average: 18%, range: 4%–39%). We concluded that when an internal capsule is not used, wall losses of lead dust in air sampling cassettes can be adequately recovered by wiping the internal wall surfaces of the cassette with a single wipe. PMID:26125330

  7. (Pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution as blood substitute for normothermic whole body rinse-out.

    PubMed

    Agishi, T; Funakoshi, Y; Honda, H; Yamagata, K; Kobayashi, M; Takahashi, M

    1988-01-01

    In order to investigate a new possibility for artificial blood with oxygen-carrying capability to be applied to other than mere supplementation, normothermic whole body rinse-out in which artificial blood deriving from perfluorochemical emulsion, Fluosol-DA 20% (Green Cross Co., Ltd., Osaka, Japan) or stabilized hemoglobin solution, (pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution (Ajinomoto Co., Ltd., Tokyo, Japan) were used as rinsing fluid for a blood purification experiment. Replacement either with approximately 150 ml/kg of Fluosol-DA or stabilized hemoglobin solution showed effective removal of digoxin at a reduction rate of 96.3% or 92.2%, respectively. However, when Fluosol-DA was used, a certain amount of perfluorochemical should be retrieved by centrifugation to avoid a possible toxic effect on the reticulo-endothelial system. Even though 3 out of 6, and 3 out of 8 dogs, respectively, survived for a long period after the procedure, the experimental dogs were very susceptible to infection.

  8. The effect of cetylpyridinium chloride-containing mouth rinses as adjuncts to toothbrushing on plaque and parameters of gingival inflammation: a systematic review.

    PubMed

    Haps, S; Slot, D E; Berchier, C E; Van der Weijden, G A

    2008-11-01

    To review the literature concerning cetylpyridinium chloride (CPC) containing mouth rinses as effective adjuncts to toothbrushing in the prevention of plaque accumulation and gingival inflammation. Medline and the Cochrane Central Register of Controlled Trials were searched up to January 2008 to identify appropriate studies. The primary outcome measurements were plaque accumulation and gingivitis. Independent screening of titles and abstracts of 3250 papers resulted in eight publications that met the criteria of eligibility. Mean values and standard deviations were obtained by data extraction. Descriptive comparisons are presented for brushing only or brushing and rinsing. Meta-analyses were performed when possible. The existing evidence supports that CPC containing mouth rinses, when used as adjuncts to either supervised or unsupervised oral hygiene, provide a small but significant additional benefit in reducing plaque accumulation and gingival inflammation.

  9. Granular parakeratosis induced by benzalkonium chloride exposure from laundry rinse aids.

    PubMed

    Robinson, Aaron J; Foster, Rachael S; Halbert, Anne R; King, Emma; Orchard, David

    2017-08-01

    Benzalkonium chloride is a quaternary ammonium cationic detergent present in a number of household products, which can act as a major skin irritant. We present the case of six children who developed granular parakeratosis after exposure to benzalkonium chloride in laundry rinse aids, presenting as a brightly erythematous, tender but minimally pruritic, intertriginous eruption followed by superficial desquamation. The eruptions resolved over 3-4 weeks after cessation of exposure. © 2016 The Australasian College of Dermatologists.

  10. Producing ultrapure wood cellulose nanofibrils and evaluating the cytotoxicity using human skin cells.

    PubMed

    Nordli, Henriette Rogstad; Chinga-Carrasco, Gary; Rokstad, Anne Mari; Pukstad, Brita

    2016-10-05

    Wood cellulose nanofibrils (CNF) have been suggested as a potential wound healing material, but its utilization is limited by FDA requirements regarding endotoxin levels. In this study a method using sodium hydroxide followed by TEMPO mediated oxidation was developed to produce ultrapure cellulose nanofibrils, with an endotoxin level of 45 endotoxin units/g (EU/g) cellulose. Scanning transmission electron microscopy (S(T)EM) revealed a highly nanofibrillated structure (lateral width of 3.7±1.3nm). Assessment of cytotoxicity and metabolic activity on Normal Human Dermal Fibroblasts and Human Epidermal Keratinocytes was done. CNF-dispersion of 50μg/ml did not affect the cells. CNF-aerogels induced a reduction of metabolic activity by the fibroblasts and keratinocytes, but no significant cell death. Cytokine profiling revealed no induction of the 27 cytokines tested upon exposure to CNF. The moisture-holding capacity of aerogels was relatively high (∼7500%), compared to a commercially available wound dressing (∼2500%), indicating that the CNF material is promising as dressing material for management of wounds with a moderate to high amount of exudate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Bare TiO2 and graphene oxide TiO2 photocatalysts on the degradation of selected pesticides and influence of the water matrix

    NASA Astrophysics Data System (ADS)

    Cruz, Marta; Gomez, Cristina; Duran-Valle, Carlos J.; Pastrana-Martínez, Luisa M.; Faria, Joaquim L.; Silva, Adrián M. T.; Faraldos, Marisol; Bahamonde, Ana

    2017-09-01

    The photocatalytic activity of a home-made titanium dioxide (TiO2) and its corresponding composite based on graphene oxide (GO), the GO-TiO2 catalyst, has been investigated under UV-vis in the photodegradation of a mixture of four pesticides classified by the European Union as priority pollutants: diuron, alachlor, isoproturon and atrazine. The influence of two water matrices (ultrapure or natural water) was also studied. Natural water led to a decrease on the degradation of the studied pollutants when the bare TiO2 photocatalyst was employed, since this water contains both inorganic and organic species that are dissolved and commonly restrain the photocatalytic process. On the contrary, the photo-efficiency of the GO-TiO2 composite seems to be less affected by water matrix variation, with very good initial pesticide photodegradation rates under both natural and ultrapure water matrices. A comparative study between GO-TiO2 and the commercial Evonik TiO2 P25 catalyst was also carried out to analyze the photocatalytic degradation of these pesticides under visible light illumination conditions. Once again, a higher photocatalytic activity was found for the GO-TiO2 composite.

  12. Quantitative repeated open application testing with a rinse-off product in methyldibromo glutaronitrile-sensitive patients: results of the IVDK.

    PubMed

    Heratizadeh, Annice; Killig, Claudia; Worm, Margitta; Soost, Stephanie; Simon, Dagmar; Bauer, Andrea; Mahler, Vera; Schuster, Christian; Szliska, Christiane; Frambach, Yvonne; Eben, Ricarda; Werfel, Thomas; Uter, Wolfgang; Schnuch, Axel

    2010-06-01

    While the use of methyldibromo glutaronitrile (MDBGN) in leave-on products is clearly associated with high sensitization or elicitation risk, such a clear-cut relation could be questioned with regard to rinse-off products. The objective of this study was to find a maximum non-eliciting concentration for rinse-off products in MDBGN patch test-positive patients. We performed a use-related test [repeated open application test (ROAT)] in patients sensitized to MDBGN with a liquid soap containing three concentrations of MDBGN (50, 200, and 400 p.p.m. MDBGN, respectively). The soap at 50 p.p.m. was used twice daily for 4 weeks. If no reaction of the skin was observed, the product with the next higher concentration was used for another 4 weeks, etc. In total, 32/37 evaluated cases [86.5%; lower exact one-sided 95% confidence limit (CL): 73.7%] did not react to any of the preparations. The remaining reacted as follows: 1/37 reacted to 50 p.p.m., 3/37 to 200 p.p.m., and 1/37 to 400 p.p.m. The cumulative non-response to 50 p.p.m. was 97.3% (lower CL: 87.8%). The majority of subjects sensitized to MDBGN-tolerated rinse-off products containing a maximum concentration of 400 p.p.m. A concentration in rinse-off products in the range of 50 p.p.m. could be regarded as safe for most individuals already sensitized. These concentrations will presumably prevent induction (sensitization) also.

  13. Alkali ocular burns in Martinique (French West Indies) Evaluation of the use of an amphoteric solution as the rinsing product.

    PubMed

    Merle, Harold; Donnio, Angélique; Ayeboua, Lucas; Michel, Franck; Thomas, Félix; Ketterle, Jeannine; Leonard, Christian; Josset, Patrice; Gerard, Max

    2005-03-01

    During the 4 years of this study, we noted 66 cases of alkali ocular burns, or approximately 16 cases per year, nearly half (45.5%) of which are due to an assault. For grade 1 and 2 burns the time elapsed to reepithelialization appears to be shorter when rinsed with Diphoterine* versus physiological solution. Comparison of the effectiveness of two rinsing solutions for emergency use: a physiological solution and an amphoteric solution (Diphoterine*, Laboratories Prevor, Valmondois, France). Description of the clinical and progressive characteristics of alkali burns treated at the University Hospital Center of Fort de France in Martinique (French West Indies). Prospective consecutive observational case series and nonrandomized comparative study. Sixty-six patients were included. The total number of burned eyes is 104. Forty-eight eyes (46%) were rinsed with physiological solution and 56 eyes (54%) with Diphoterine*. All patients benefited from an ocular rinse with 500ml of physiological solution or Diphoterine*, followed by a complete ophthalmologic exam. The ocular injuries were classified according to the Roper-Hall modification of the Hughes classification system. The same standardized therapeutic protocol was applied and adapted to the seriousness of the burn. Demographic data, time to corneal reepithelialization, final best corrected visual acuity and complications were analysed. Twenty-eight (42.4%) patients have a unilateral burn and 38 (57.6%) patients have bilateral burns. In decreasing order of frequency, the circumstances surrounding the injury are: assaults in 45.5% of cases (n=30), work-related accidents in 32% of cases (n=31), and domestic accidents in 23% of cases (n=15). For grade 1 and 2 burns the time elapsed to reepithelialization appears to be shorter when rinsed with Diphoterine* versus physiological solution (respectively): 1.9+/-1 days versus 11.1+/-1.4 days (p=10(-7)) and 5.6+/-4.9 days versus 10+/-9.2 days (p=0.02). For grade 3 and 4 burns

  14. Effects of potassium oxalate on knoop hardness of etch-and-rinse adhesives.

    PubMed

    Silva, S M A; Malacarne-Zanon, J; Carvalho, R M; Alves, M C; De Goes, M F; Anido-Anido, A; Carrilho, M R

    2012-01-01

    The objective of this study was to determine whether the hardness of etch-and-rinse adhesives may be affected by the pretreatment of acid-etched dentin with potassium oxalate desensitizer. Unerupted human third molars were cut into crown segments by removing the occlusal enamel and roots. The pulp chamber of these crown segments was connected to a syringe barrel filled with phosphate-buffered saline so that the moisture of dentin was maintained during the bonding procedures. Three etch-and-rinse adhesives-two two-step systems (Adper Single Bond 2 [SB], One-Step [OS]) and one three-step system (Adper Scotchbond Multi-Purpose [MP])-were applied to acid-etched dentin that had been treated (experimental groups) or not (control groups) with potassium oxalate (BisBlock). The Knoop hardness (KHN) of adhesives was taken at different sites of the outer surface of the adhesive-bonded dentin. The KHN of the three tested adhesives applied to acid-etched dentin treated with potassium oxalate was significantly lower than that exhibited by the respective controls (not treated with oxalate; p<0.05). Regardless of the adhesive, the treatment with potassium oxalate reduced the adhesives' KHN (p<0.05), with the OS system exhibiting the lowest KHN compared with the MP and SB systems.

  15. Purifying Water by Imbibition

    NASA Technical Reports Server (NTRS)

    Lawton, E. A.

    1986-01-01

    Concept for purifying water uses absorbent material to remove organic substances. Entire bulk of material employed, not just surface. Proposed purification process uses inexpensive equipment and low energy. Material is methyl acrylate polymer. Material cheap and regenerated by rinsing with methanol or by allowing absorbed compounds to evaporate from it.

  16. Influence of flooring type during transport and holding on bacteria recovery from broiler carcass rinses before and after defeathering.

    PubMed

    Buhr, R J; Cason, J A; Dickens, J A; Hinton, A; Ingram, K D

    2000-03-01

    Four trials were conducted to determine whether conventional solid or elevated wire mesh flooring, during transport and holding of broilers prior to slaughter, influenced the number of bacteria recovered from feathered and defeathered carcasses. After 4 h off feed, 7-wk-old broilers were placed at commercial density into a modified commercial transport dump-coop on either fiberglass sheeting or 2.54x2.54 cm wire mesh flooring that allowed feces to fall through. Broilers were transported for 1 h and then held for 13 h under a covered shed before processing. Broilers were killed by electrocution, and the vents were plugged to prevent escape of feces. External carcass rinses were obtained twice (from the same carcass) from eight broilers per flooring treatment per trial, before scalding and defeathering and again after defeathering and removal of the head and feet. Greater numbers of total aerobes, coliforms, and Escherichia coli were recovered from feathered carcasses than from defeathered carcasses. Campylobacter count was also less for defeathered than feathered carcasses from the solid flooring treatment but did not significantly decrease following defeathering of carcasses from the wire flooring. The incidence of Campylobacter-positive carcasses was reduced following defeathering for both flooring treatments, but the percentage of Salmonellae-positive carcasses remained constant. Coliform (log10 6.20 vs. 5.63 cfu/mL of rinse) and E. coli (log10 5.93 vs. 5.36) counts in the feathered rinses were significantly higher for the solid flooring compared with wire flooring, respectively. After defeathering, the number of coliforms (log10 3.12) and E. coli (log10 2.91) recovered did not differ between flooring treatments. Aerobic plate count (log10 7.06 and 4.02), Campylobacter count (log10 2.49 and 1.80), and the incidence of Campylobacter-positive (44 and 11%) and Salmonellae-positive (52 and 50%) carcasses for feathered and defeathered rinses, respectively, did not

  17. Neutralization of residual antimicrobial processing chemicals in broiler carcass rinse for improved detection of Campylobacter

    USDA-ARS?s Scientific Manuscript database

    Campylobacter presence on broiler carcasses in the U.S. is regulated. Processors may apply antimicrobial processing aids as a spray or immersion to lower contamination on carcasses. In the U.S., broiler carcasses are generally sampled by whole carcass rinse and the potential exists for residual le...

  18. WaterSense Specification for Commercial Pre-Rinse Spray Valves Supporting Statement

    EPA Pesticide Factsheets

    The U.S. Environmental Protection Agency’s (EPA’s) WaterSense program released a specification for PRSVs to earn the WaterSense label on September 19, 2013, in order to further improve the nation’s water and energy efficiency.

  19. The effect of carbohydrate mouth rinse on performance, biochemical and psychophysiological variables during a cycling time trial: a crossover randomized trial.

    PubMed

    Ferreira, Amanda M J; Farias-Junior, Luiz F; Mota, Thaynan A A; Elsangedy, Hassan M; Marcadenti, Aline; Lemos, Telma M A M; Okano, Alexandre H; Fayh, Ana P T

    2018-01-01

    The hypothesis of the central effect of carbohydrate mouth rinse (CMR) on performance improvement in a fed state has not been established, and its psychophysiological responses have not yet been described. The aim of this study was to evaluate the effect of CMR in athletes fed state on performance, biochemical and psychophysiological responses compared to ad libitum water intake. Eleven trained male cyclists completed a randomized, crossover trial, which consisted of a 30 km cycle ergometer at self-selected intensity and in a fed state. Subjects were under random influence of the following interventions: CMR with a 6% unflavored maltodextrin solution; mouth rinsing with a placebo solution (PMR); drinking "ad libitum" (DAL). The time for completion of the test (min), heart rate (bpm) and power (watts), rating of perceived exertion (RPE), affective response, blood glucose (mg/dL) and lactate (mmol/DL), were evaluated before, during and immediately after the test, while insulin (uIL/mL), cortisol (μg/dL) and creatine kinase (U/L) levels were measured before, immediately after the test and 30 min after the test. Time for completion of the 30 km trial did not differ significantly among CMR, PMR and DAL interventions (means = 54.5 ± 2.9, 54.7 ± 2.9 and 54.5 ± 2.5 min, respectively; p  = 0.82). RPE and affective response were higher in DAL intervention ( p  < 0.01). Glucose, insulin, cortisol and creatine kinase responses showed no significant difference among interventions. In a fed state, CMR has not caused metabolic changes, and it has not improved physical performance compared to ad libitum water intake, but demonstrated a possible central effect. ReBec registration number: RBR-4vpwkg. Available in http://www.ensaiosclinicos.gov.br/rg/?q=RBR-4vpwkg.

  20. Effects of carbohydrate mouth rinse and caffeine on high-intensity interval running in a fed state.

    PubMed

    Devenney, Simon; Mangan, Shane; Shortall, Marcus; Collins, Kieran

    2018-05-01

    The current study aims to identify if mouth rinsing with a 6% carbohydrate mouth-rinse (CMR) solution and mouth rinsing and ingestion of caffeine (CMR+CAFF) can affect exercise performance during steady-state (SS) running and high-intensity intervals (HIIT) in comparison with a 0% control solution (PLA) when in a fed state. Eight recreationally trained males completed 3 trials (CMR, CMR+CAFF, and PLA) of 45 min SS running and an HIIT protocol (90% peak treadmill velocity) until fatigue in a double blinded, repeated-measures study. Participants ingested a capsule of either CAFF or PLA before and after SS. Participants received a 25-mL bolus of carbohydrate solution (CMR and CMR+CAFF trials) or taste-matched PLA (PLA trial) prior to HIIT protocol and after every second effort. Heart rate and lactate responses were recorded throughout the SS and HIIT protocol. CMR+CAFF was significantly different when compared with PLA (p = 0.001; Cohens d = 1.34) and CMR (p = 0.031; Cohens d = 0.87) in relation to distance covered before fatigue. Although there was no significant difference between CMR and PLA, there was a small benefit for CMR (p = 0.218; Cohens d = 0.46). Results indicate that CMR and ingestion of CAFF leads to improvements in performance during interval sessions while participants were in a fed state. These findings indicate that the regular use of CMR can decrease the risk of gastrointestinal distress reported by athletes, which can be applicable to athletes in a real-world setting.

  1. Morphology of the Dentin-resin Interface yielded by Two-step Etch-and-rinse Adhesives with Different Solvents.

    PubMed

    Ferreira, João C; Pires, Patrícia T; de Azevedo, Álvaro F; Arantes-Oliveira, Sofia; Silva, Mário J; de Melo, Paulo R

    2017-10-01

    The study aimed to analyze the morphology of the dentin-resin interface yielded by two-step etch-and-rinse adhesive systems with different solvents and compositions. A total of 32 dentine disks were prepared and randomly assigned to four groups of one-bottle etch-and-rinse adhesive systems containing different solvents: group I, Adper Scotchbond-IXT™ (ethanol/water); group II, XP-Bond™ (tertiary butanol); group III, Prime and Bond NT ® (acetone); and group IV, One Coat bond® (5% water). Adhesive systems were applied onto dentin disks, which were then thermal cycled, divided into two hemi-disks (n = 16), and prepared for field-emission scanning electron microscopy to examine the dentin-resin interdiffusion zone. Microphotographs were scanned and data were processed. Data were compared with analysis of variance multivariant test after Kolmogorov-Smirnov and Shapiro-Wilk tests using Statistic Package for the Social Sciences. The adhesive layer thickness average found was group I: 45.9 ± 13.41 urn, group II: 20.6 ± 16.32 urn, group III: 17.7 ± 11.75 urn, and group IV: 50.7 ± 27.81 urn. Significant differences were found between groups I and IV and groups II and III (p < 0.000). Groups I (3.23 ± 0.53 μm) and II (3.13 ± 0.73 μm) yielded significantly thicker hybrid layers than groups III (2.53 ± 0.50 μm) and IV (1.84 ± 0.27 μm) (p < 0.003). Group III presented a less homogeneous hybrid layer, with some gaps. Tag length average was greater in groups II (111.0 ± 36.92 μm) and IV (128.9 ± 78.38 μm) than in groups I (61.5 ± 18.10 μm) and III (68.6 ± 15.84 μm) (p < 0.008). Adhesives systems with different solvents led to significant differences in the dentin-resin interface morphology. Solvents role in adhesives bond strength should be considered together with the other adhesive system components. The adhesive containing tertiary butanol, in addition, seems to originate a good-quality hybrid layer and long, entangled tags and also appears to have

  2. [Research on cleaning rate of the C-shaped canal treated by manual or rotary endodontic file combined with ultrasonic rinsing].

    PubMed

    Wang, Jing; Gao, Yan; Wang, Qing-shan; Zhang, Yan; Rong, Li; Wang, Jiu

    2014-08-01

    To evaluate the cleaning effect of the C-shaped canal treated by manual K file and ProTaper rotary endodontic file combined with ultrasonic cleaning, and find a better cleaning program for the C-shaped root canal. Fifty mandibular second molars were randomly divided into 5 groups: K file group, K file+ultrasonic rinsing group, ProTaper group, ProTaper+ultrasonic rinsing group and the control group. After initial shaping and cleaning, the mandibular second molars were soaked in formalin and stained. Under microscopy, the cleaning rate of necrotic tissue and cutting area were observed and analyzed. The data was processed with SPSS 17.0 software package. The cleaning rates of the treated groups were significantly higher than that of the control group (P<0.05); In each treatment group, the cleaning rate of the apex was significantly lower than that of the crown and central part (P<0.05); The cutting score of ProTaper+ultrasonic cleaning group was lower than that of the other treatment groups; The cutting score of the K file+ultrasonic rinsing group was significantly lower than that of the K file group (P<0.05); The cutting score and cleaning rate were negatively correlated (r=-0.712, P=0.000 ), the linear regression was the cleaning rate =98.325-4.325 × wall cutting score (R=0.454, P<0.05). In the process of shaping and cleaning of C-shaped canal, it is recommended that the ProTaper nickel-titanium rotary endodontic file should be chosen to clean the top of the taproot pipe and combined with ultrasonic rinsing to achieve better results.

  3. Decontaminating materials used in ground water sampling devices: Organic contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, L.V.; Ranney, T.A.

    2000-12-31

    In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymetic tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption. The contaminants weremore » removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs form the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105 C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.« less

  4. The in vitro efficacy of SunSmile® Fruit & Vegetable Rinse against pathogenic strains of Prototheca algae that cause mastitis in cows.

    PubMed

    Grzesiak, B; Krukowski, H; Głowacka, A

    2018-04-16

    The research concerns algae of the genus Prototheca. They are found in the natural environment and they can cause a disease in animals and humans called protothecosis. The aim of the study was to evaluate the in vitro activity of the fruit and vegetable rinse agent SunSmile ® Fruit & Vegetable Rinse (Sunrider International) against P. zopfii isolates. The materials consisted of ten P. zopfii strains isolated from the milk of cows with mastitis. The following antifungal chemotherapeutic agents were also used in the study for comparison: nystatin, ketoconazole, amphothericin B, miconazole, clotrimazole, econazole, fluconazole, and flucytosine. The tube dilution method were used to evaluate the effect of a fruit and vegetable rinse agent and the disc-diffusion method to evaluate the effect of antifungal chemotherapeutic agents on P. zopfii strains. All tested strains of P. zopfii were susceptible to the action of the SunSmile ® agent. The MMC was in the range of 0.0024-0.0190%. The SunSmile ® Fruit & Vegetable Rinse can be used in prevention of mastitis in cows and in human protothecosis due to its safe, natural composition and efficacy. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Association between clinical and salivary microbial parameters during orthodontic treatment with removable appliances with or without use of fluoride mouth rinse.

    PubMed

    Zingler, S; Pritsch, M; Lux, C J; Kneist, S

    2016-09-01

    To evaluate the correlation between clinical and salivary microbial parameters during treatment with removable orthodontic appliances with or without use of fluoride mouth rinse. A group of 48 patients completed this randomized, controlled, parallel-group, clinical pilot study. 24 patients of the test group (TG) rinsed after tooth brushing with a fluoride mouth rinse (100 ppm AmF/150 ppm NaF) while 21 patients of the control group (CG) did not. Clinical parameters [Approximal Plaque Index (API), Papillary Bleeding Index (PBI)] as well as levels of salivary mutans streptococci (MS) and lactobacilli (LB) were assessed at baseline and after 3, 6, 9 and 12 months. Compliance was documented by participants. Appliance wear-times were estimated retrospectively by the patients. All participants received the same brushing instructions and were supplied with the same toothbrush/toothpaste. A significant correlation of API values with MS levels (p=0.0003) or with LB levels (p=0.001) was observed. Furthermore, appliance wear-times were significantly associated with API values (p=0.02). The changes of MS or LB levels between beginning and end of the study did not differ significantly between study groups. The changes of the API scores showed slightly different median values (-3.5 in the TG vs. 0 in the CG), the difference, however, was not significant. The results emphasise the need for a careful monitoring of the oral hygiene status in patients with removable orthodontic appliances. Larger controlled clinical trials are necessary to investigate treatment options such as use of supplementary fluoride mouth rinse.

  6. Time-delayed transition of normal-to-abnormal glow in pin-to-water discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, S.-Y.; Byeon, Y.-S.; Yoo, S.

    2016-08-15

    Time-delayed transition of normal-to-abnormal glow was investigated in discharge between spoke-like pins and ultrapure water by applying AC-driven power at a frequency of 14.3 kHz at atmospheric pressure. The normal-to-abnormal transition can be recognized from the slope changes of current density, gas temperature, electrode temperature, and OH density. The slope changes took place in tens of minutes rather than just after discharge, in other words, the transition was delayed. The time-delay of the transition was caused by the interaction between the plasma and water. The plasma affected water properties, and then the water affected plasma properties.

  7. High carrier mobility in ultrapure diamond measured by time-resolved cyclotron resonance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akimoto, Ikuko, E-mail: akimoto@sys.wakayama-u.ac.jp; Handa, Yushi; Fukai, Katsuyuki

    2014-07-21

    We have performed time-resolved cyclotron resonance measurements in ultrapure diamond crystals for the temperature range of T=7.3–40 K and obtained the temperature-dependent momentum relaxation times based on the cyclotron resonance widths for optically generated electrons and holes. The relaxation time follows a T{sup −3/2} law down to 12 K, which is expected for acoustic-phonon scattering without impurity effect because of the high purity of our samples. The deviation from the law at lower temperatures is explained by the impurity scattering and the breakdown of the high-temperature approximation for the phonon scattering. We extract the carrier drift mobility by using the directly measuredmore » effective masses and the relaxation times. The mobility at 10 K for 600 ns delay time after optical injection is found to be μ{sub e}=1.5×10{sup 6} cm{sup 2}/V s for the electrons, and μ{sub lh}=2.3×10{sup 6} cm{sup 2}/V s and  μ{sub hh}=2.4×10{sup 5} cm{sup 2}/V s for the light and heavy holes, respectively. These high values are achieved by our high-sensitivity detection for low-density carriers (at <10{sup 11} cm{sup −3}) free from the carrier-carrier scattering as well as by the suppression of the impurity scattering in the high-purity samples.« less

  8. Postmarketing surveillance study of permethrin creme rinse.

    PubMed

    Andrews, E B; Joseph, M C; Magenheim, M J; Tilson, H H; Doi, P A; Schultz, M W

    1992-06-01

    An observational, epidemiological study was undertaken to evaluate the safety of permethrin 1% creme rinse (Nix) for treatment of head lice infestations. Thirty-seven local public health departments enrolled a total of 38,160 patients for 47,578 treatments with permethrin or other pediculicides from September 1, 1986, through January 31, 1988. Follow-up safety information was collected between 7 and 14 days following treatment via return visit or telephone contact. One hundred three adverse events were reported among 41,955 evaluable treatments. The rates of reported adverse events were 2.2 per 1000 treatments among permethrin treatments, 3.4 per 1000 treatments among lindane treatments, and 1.5 per 1000 treatments among other over-the-counter treatments. No serious, unexpected adverse events were detected in the 18,950 patients treated with permethrin. This study confirmed the safety profile of permethrin in conditions of general use, as seen in clinical trials. Postmarketing safety monitoring in public health departments of drugs used to treat public health conditions was shown to be feasible.

  9. Analysis of multi-class preservatives in leave-on and rinse-off cosmetics by matrix solid-phase dispersion.

    PubMed

    Sanchez-Prado, Lucia; Alvarez-Rivera, Gerardo; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Llompart, Maria

    2011-12-01

    Matrix solid-phase extraction has been successfully applied for the determination of multi-class preservatives in a wide variety of cosmetic samples including rinse-off and leave-on products. After extraction, derivatization with acetic anhydride, and gas chromatography-mass spectrometry analysis were performed. Optimization studies were done on real non-spiked and spiked leave-on and rinse-off cosmetic samples. The selection of the most suitable extraction conditions was made using statistical tools such as ANOVA, as well as factorial experimental designs. The final optimized conditions were common for both groups of cosmetics and included the dispersion of the sample with Florisil (1:4), and the elution of the MSPD column with 5 mL of hexane/acetone (1:1). After derivatization, the extract was analyzed without any further clean-up or concentration step. Accuracy, precision, linearity and detection limits were evaluated to assess the performance of the proposed method. The recovery studies on leave-on and rinse-off cosmetics gave satisfactory values (>78% for all analytes in all the samples) with an average relative standard deviation value of 4.2%. The quantification limits were well below those set by the international cosmetic regulations, making this multi-component analytical method suitable for routine control. The analysis of a broad range of cosmetics including body milk, moisturizing creams, anti-stretch marks creams, hand creams, deodorant, shampoos, liquid soaps, makeup, sun milk, hand soaps, among others, demonstrated the high use of most of the target preservatives, especially butylated hydroxytoluene, methylparaben, propylparaben, and butylparaben.

  10. Salmonella serotype diversity from broiler carcass rinses evaluated by two secondary enrichments along with two plating media

    USDA-ARS?s Scientific Manuscript database

    Salmonella diversity on broiler carcasses has received significant attention in recent years, due to emphasis being placed on recovery of certain serotypes related to human attribution studies. The objective of this study was to evaluate Salmonella diversity from broiler carcass rinses by two culti...

  11. CpG island methylation profile in non-invasive oral rinse samples is predictive of oral and pharyngeal carcinoma.

    PubMed

    Langevin, Scott M; Eliot, Melissa; Butler, Rondi A; Cheong, Agnes; Zhang, Xiang; McClean, Michael D; Koestler, Devin C; Kelsey, Karl T

    2015-01-01

    There are currently no screening tests in routine use for oral and pharyngeal cancer beyond visual inspection and palpation, which are provided on an opportunistic basis, indicating a need for development of novel methods for early detection, particularly in high-risk populations. We sought to address this need through comprehensive interrogation of CpG island methylation in oral rinse samples. We used the Infinium HumanMethylation450 BeadArray to interrogate DNA methylation in oral rinse samples collected from 154 patients with incident oral or pharyngeal carcinoma prior to treatment and 72 cancer-free control subjects. Subjects were randomly allocated to either a training or a testing set. For each subject, average methylation was calculated for each CpG island represented on the array. We applied a semi-supervised recursively partitioned mixture model to the CpG island methylation data to identify a classifier for prediction of case status in the training set. We then applied the resultant classifier to the testing set for validation and to assess the predictive accuracy. We identified a methylation classifier comprised of 22 CpG islands, which predicted oral and pharyngeal carcinoma with a high degree of accuracy (AUC = 0.92, 95 % CI 0.86, 0.98). This novel methylation panel is a strong predictor of oral and pharyngeal carcinoma case status in oral rinse samples and may have utility in early detection and post-treatment follow-up.

  12. Does ErbiumiYttrium-Aluminum-Garnet Laser to Enamel improve the Performance of Etch-and-rinse and Universal Adhesives?

    PubMed

    De Jesus Tavarez, Rudys R; Rodrigues, Lorrany Lc; Diniz, Ana C; Lage, Lucas M; Torres, Carlos Rg; Bandeca, Matheus C; Firoozmand, Leily M

    2018-03-01

    This study aims to evaluate the effect of erbium: Yttrium-aluminum-garnet (Er:YAG) laser irradiation on the enamel microshear bond strength (μSBS), followed by the utilization of etch-and-rinse and universal adhesive systems. A total of 32 molars were sectioned in the mesiodistal direction producing 64 samples that were randomized into two groups (n = 32): single bond 2 (SB2) (etch-and-rinse system; 3M), SB universal (SBU) (universal etching system; The SB2 and SBU groups were then divided into two subgroups (n = 16): (i) enamel was irradiated with an Er:YAG laser (λ = 2.94 μm, 60 mJ, 10 Hz), and (ii) enamel served as a control. The samples were restored with TPH3 (Dentsply), stored in artificial saliva for 24 hours, and subjected to a micro-shear test. Kruskal-Wallis (p < 0.05) and Mann-Whitney U tests indicated no significant differences in uSBS between the groups, and the fractures were predominately at the resin-enamel interface. The previous irradiation of enamel with Er:YAG laser does not interfere with the performance of simplified two-step etch-and-rinse and universal adhesive systems. The increasing use of Er:YAG laser is important to evaluate the influence of this irradiation on the adhesion of restorative materials. Thus, to obtain the longevity of the restorative procedures, it is necessary to know the result of the association of the present adhesive systems to the irradiated substrate.

  13. Salivary pH after a glucose rinse: effect of a new mucoadhesive spray (Cariex) based on sodium bicarbonate and xylitol.

    PubMed

    Abbate, G M; Levrini, L; Caria, M P

    2014-01-01

    This study evaluated whether sodium bicarbonate applied on the oral mucosa through a new mucoadhesive spray (Cariex) could control a drop in salivary pH after a glucose rinse, and therefore enhance the buffering potential of saliva. A sample of 50 healthy adults was selected. At day 1, the measurement of salivary pH was performed in the lower fornix in correspondence with the lower molars. Each subject rinsed with 10 ml of a 10% glucose solution and then pH was monitored continually for 40 minutes. At day 2, the same experimental procedure was repeated and three shots of the spray were administered on the oral mucosa. The tested spray is composed of sodium bicarbonate, xylitol, and excipients. Without the mucoadhesive spray, salivary pH became significantly lower following the glucose rinse (p < 0.01). Following the spray, the time in which the pH remained lower than 6.0 was reduced statistically significantly (p < 0.01). A continual rise of salivary pH was observed for the 40 minutes in which the pH recording was performed. Conclusions: The use of a sodium bicarbonate spray on the mucosa was shown to control the lowering of salivary pH following carbohydrate consumption, and might therefore add to the prevention of caries and dental erosion.

  14. Long-term efficacy of a 0.07% cetylpyridinium chloride mouth rinse in relation to plaque and gingivitis: a 6-month randomized, vehicle-controlled clinical trial.

    PubMed

    Van Leeuwen, M P C; Rosema, N A M; Versteeg, P A; Slot, D E; Van Winkelhoff, A J; Van der Weijden, G A

    2015-05-01

    To evaluate the effectiveness of 0.07% cetylpyridinium chloride (CPC) mouth rinse for reduction of gingival inflammation and inhibition of plaque compared to a vehicle control (VC) mouth rinse over a 6-month period. Participants (n = 62) used their randomly assigned product as adjunct to toothbrushing. Bleeding, plaque and staining scores were assessed at baseline, 3 and 6 months. Plaque and saliva samples were taken at each assessment monitoring possible shifts in the composition of the microbiota. A significant difference (P = 0.002) in favour of the CPC mouth rinse, with respect to plaque scores, was found. Bleeding scores at 6 months were not significantly different (P = 0.089). However, when correcting for baseline values, a tendency towards a significant difference in bleeding scores at end trail was observed in favour of the CPC mouth rinse (P = 0.061). Regarding staining at 3 and 6 months, a small but significant difference (8.6% and 10.4%, respectively) (P < 0.0001) was observed with lower scores for the VC group. There was a significant reduction in total anaerobic count in the CPC group at 6 months (P < 0.05). The ratio of aerobes/anaerobes was markedly increased at 3 months, especially in the CPC group. No further differences were observed between groups at 6 months. The use of 0.07% CPC mouth rinse was significantly more effective in reducing plaque scores than the vehicle control. Bleeding scores were not different at 6 months. The test product was well accepted and did not cause any serious clinical side effects or negatively affected the microbiota. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Next-Generation Sequencing Identifies Gene Mutations That Are Predictive of Malignancy in Residual Needle Rinses Collected From Fine-Needle Aspirations of Thyroid Nodules.

    PubMed

    Fuller, Maren Y; Mody, Dina; Hull, April; Pepper, Kristi; Hendrickson, Heather; Olsen, Randall

    2018-02-01

    - Thyroid nodules have a prevalence of approximately 70% in adults. Fine-needle aspiration (FNA) is a minimally invasive, cost-effective, standard method to collect tissue from thyroid nodules for cytologic examination. However, approximately 15% of thyroid FNA specimens cannot be unambiguously diagnosed as benign or malignant. - To investigate whether clinically actionable data can be obtained using next-generation sequencing of residual needle rinse material. - A total of 24 residual needle rinse specimens with malignant (n = 6), indeterminate (n = 9), or benign (n = 9) thyroid FNA diagnoses were analyzed in our clinical molecular diagnostics laboratory using next-generation sequencing assays designed to detect gene mutations and translocations that commonly occur in thyroid cancer. Results were correlated with surgical diagnoses and clinical outcomes. - Interpretable data were generated from 23 of 24 residual needle rinse specimens. Consistent with its well-known role in thyroid malignancy, BRAF V600E mutations were detected in 4 malignant cases. An NRAS mutation was detected in 1 benign case. No mutations were detected from specimens with indeterminate diagnoses. - Our data demonstrate that residual thyroid FNA needle rinses are an adequate source of material for molecular diagnostic testing. Importantly, detection of a mutation implicated in thyroid malignancy was predictive of the final surgical diagnosis and clinical outcome. Our strategy to triage thyroid nodules with indeterminate cytology with molecular testing eliminates the need to perform additional FNA passes into dedicated media or to schedule additional invasive procedures. Further investigation with a larger sample size to confirm the clinical utility of our proposed strategy is underway.

  16. Treatment of shelter cats with oral terbinafine and concurrent lime sulphur rinses.

    PubMed

    Moriello, Karen; Coyner, Kimberly; Trimmer, Ann; Newbury, Sandra; Kunder, Darcie

    2013-12-01

    Dermatophytosis is an important contagious and infectious skin disease in an animal shelter. Itraconazole is the commonly used systemic antifungal drug, but it is expensive in some countries and, at times, difficult to obtain. Terbinafine is a fungicidal allylamine with documented in vitro and in vivo efficacy against Microsporum canis in pet cats and in cats with experimental infections. To describe the use of oral terbinafine for the treatment of M. canis dermatophytosis in shelter cats. The response to treatment of 85 shelter cats with naturally occurring M. canis dermatophytosis was monitored by examination, weekly toothbrush fungal cultures and the number of colony-forming units on fungal culture plates. Cats were treated with either 14 (n = 21) or 21 days (n = 64) of terbinafine per os (p.o.) along with concurrent twice weekly lime sulphur rinses and daily environmental disinfection. Cats treated with 14 days of terbinafine p.o. showed an initial response to therapy but by week 6 had relapsed and required rescue therapy with a course of itraconazole (10 mg/kg p.o.) to obtain a cure. Cats treated with 21 days of terbinafine p.o. showed a response to treatment similar to published reports using itraconazole p.o. for 21 days. The mean and median number of days to mycological cure was 22.70 (range 13-39). Terbinafine was well tolerated. None of the cats developed oral lesions postgrooming of lime sulphur rinses. Where itraconazole is not available, substitution with terbinafine in established protocols may allow shelters to treat cats that otherwise would go untreated. © 2013 ESVD and ACVD.

  17. Development of an Ultra-Pure, Carrier-Free 209Po Solution Standard

    PubMed Central

    Collé, R.; Fitzgerald, R. P.; Laureano-Perez, L.

    2015-01-01

    Ultra-pure, carrier-free 209Po solution standards have been prepared and standardized for their massic alpha-particle emission rate. The standards, which will be disseminated by the National Institute of Standards and Technology (NIST) as Standard Reference Material SRM 4326a, have a mean mass of (5.169 ± 0.003) g of a solution of polonium in nominal 2.0 mol▪L−1 HCl (having a solution density of (1.032 ± 0.002) g▪ mL−1 at 20 °C) that are contained in 5 mL, flame-sealed, borosilicate glass ampoules. They are certified to contain a 209Po massic alpha-particle emission rate of (39.01 ± 0.18) s−1▪g−1 as of a reference time of 1200 EST, 01 December 2013. This new standard series replaces SRM 4326 that was issued by NIST in 1994. The standardization was based on 4πα liquid scintillation (LS) spectrometry with two different LS counting systems and under wide variations in measurement and counting source conditions. The methodology for the standardization, with corrections for detection of the low-energy conversion electrons from the delayed 2 keV isomeric state in 205Pb and for the radiations accompanying the small 0.45 % electron-capture branch to 209Bi, involves a unique spectral analysis procedure that is specific for the case of 209Po decay. The entire measurement protocol is similar, but revised and improved from that used for SRM 4326. Spectroscopic impurity analyses revealed that no photon-emitting or alpha-emitting radionuclidic impurities were detected. The most common impurity associated with 209Po is 208Po and the activity ratio of 208Po/209Po was < 10−7. PMID:26958444

  18. Cytological changes in the oral mucosa after use of a mouth rinse with alcohol: A prospective double blind control study

    PubMed Central

    Vera-Sempere, Francisco; Marzal, Cristina; Pellín-Carcelén, Ana; Martí-Bonmatí, Ezequiel; Bagan, Leticia

    2012-01-01

    Aim: The aim of this preliminary study was to detect cytological changes in the oral mucosa after using a mouth wash with alcohol. Material and Methods: A prospective double-blind, controlled study was performed, for 6 months. Group 1 consisted of 30 subjects who used a mouth rinse with 26.9% of alcohol [Listerine®] and Group 2 consisted of 30 subjects who used a mouth rinse with the same ingredients but with no alcohol. We obtained three cytological samples from the oral mucosa. The presence of cytological atypia, binucleation and karyorrhesis, and type of cells were studied. We also used a fluorescent in situ hybridization technique (FISH) in 15 samples in each group, for the micronucleus. Results: We found no clinical mucosal alteration after using the mouth wash at the end of the study in either group. We observed no cytological differences between the groups at the end of the study (p>0.05). Regarding the study of the micronucleus by FISH, we observed no significant difference between the groups (p>0.05). Conclusions: Our results showed no cytological alteration in patients using a mouth rinse with alcohol, but these findings should be considered preliminary results, to be confirmed in a greater sample of patients. Key words:Mouth wash, oral mucosa, cytological change, alcohol. PMID:23085712

  19. Synthesis and evaluation of ultra-pure rare-earth-coped glass for laser refrigeration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, Wendy M; Hehlen, Markus P; Epstein, Richard I

    2009-01-01

    Significant progress has been made in synthesizing and characterizing ultra-pure, rare-earth doped ZIBLAN (ZrF{sub 4}-InF{sub 3}BaF{sub 2}-LaF{sub 3}-AlF{sub 3}-NaF) glass capable of laser refrigeration. The glass was produced from fluorides which were purified and subsequently treated with hydrofluoric gas at elevated temperatures to remove impurities before glass formation. Several Yb3 +-doped samples were studied with degrees of purity and composition with successive iterations producing an improved material. We have developed a non-invasive, spectroscopic technique, two band differential luminescence thermometry (TBDLT), to evaluate the intrinsic quality of the ytterbium doped ZIBLAN used for laser cooling experiments. TBDLT measures local temperature changesmore » within an illuminated volume resulting solely from changes in the relative thermal population of the excited state levels. This TBDLT technique utilizes two commercially available band pass filters to select and integrate the 'difference regions' of interest in the luminescence spectra. The goal is to determine the minimum temperature to which the ytterbium sample can cool on the local scale, unphased by surface heating. This temperature where heating and cooling are exactly balanced is the zero crossing temperature (ZCT) and can be used as a measure for the presence of impurities and the overall quality of the laser cooling material. Overall, favorable results were obtained from 1 % Yb3+-doped glass, indicating our glasses are desirable for laser refrigeration.« less

  20. Zn-doped etch-and-rinse model dentin adhesives: Dentin bond integrity, biocompatibility, and properties.

    PubMed

    Barcellos, Daphne Câmara; Fonseca, Beatriz Maria; Pucci, César Rogério; Cavalcanti, Bruno das Neves; Persici, Erasmo De Souza; Gonçalves, Sérgio Eduardo de Paiva

    2016-07-01

    This study assessed a 6 month resin/dentin bond's durability and cytotoxic effect of Zn-doped model dentin adhesives. The mechanical and physicochemical properties were also tested. A model etch-and-rinse single-bottle adhesive was formulated (55wt.% Bis-GMA, 45wt.% HEMA, 0.5wt.% CQ, 0.5wt.% DMAEMA) and Zinc methacrylate (Zn-Mt) or ZnO nanoparticles (ZnOn) were added to the model's adhesive, resulting in three groups: Group Control (control model adhesive); Group Zn-Mt (1wt.% Zn-Mt incorporated to adhesive) and Group ZnOn (1wt.% ZnOn incorporated to adhesive). The microtensile bond strength (mTBS) was assessed after 24h or 6 months in water storage. Mechanical properties (diametral tensile strength/DTS, flexural strength/FS, flexural modulus/FM, resilience modulus/RM, and compressive strength/CS) and physicochemical properties (polymerization shrinkage/PS, contact angle/CA, water sorption/WS, and water solubility/WS) were also tested. Cytotoxicity was evaluated with SRB biochemical assay. No significant difference in the DTS, FS, FM, CS, CA, WS, and WS were found when 1% of ZnOn or Zn-Mt was added to the model dentin adhesive. Group Zn-Mt decreased the RM of adhesive. Groups Zn-Mt and ZnOn decreased the PS of adhesives. Group ZnOn reduced the cytotoxicity of adhesive. Group ZnOn preserved mTBS after 6 months storage without degradation areas as seen by SEM analysis. The 1wt.% ZnOn may preserve the integrity of the hybrid layer and may reduce cytotoxicity and polymerization shrinkage of model dentin adhesive. The addition of Zn-Mt to the adhesive had no beneficial effects. Copyright © 2016 The Academy of Dental Materials. All rights reserved.

  1. Toward industrial scale synthesis of ultrapure singlet nanoparticles with controllable sizes in a continuous gas-phase process

    NASA Astrophysics Data System (ADS)

    Feng, Jicheng; Biskos, George; Schmidt-Ott, Andreas

    2015-10-01

    Continuous gas-phase synthesis of nanoparticles is associated with rapid agglomeration, which can be a limiting factor for numerous applications. In this report, we challenge this paradigm by providing experimental evidence to support that gas-phase methods can be used to produce ultrapure non-agglomerated “singlet” nanoparticles having tunable sizes at room temperature. By controlling the temperature in the particle growth zone to guarantee complete coalescence of colliding entities, the size of singlets in principle can be regulated from that of single atoms to any desired value. We assess our results in the context of a simple analytical model to explore the dependence of singlet size on the operating conditions. Agreement of the model with experimental measurements shows that these methods can be effectively used for producing singlets that can be processed further by many alternative approaches. Combined with the capabilities of up-scaling and unlimited mixing that spark ablation enables, this study provides an easy-to-use concept for producing the key building blocks for low-cost industrial-scale nanofabrication of advanced materials.

  2. Effect of five commercial mouth rinses on the microhardness of a nanofilled resin composite restorative material: An in vitro study

    PubMed Central

    Jyothi, KN; Crasta, Shanol; Venugopal, P

    2012-01-01

    Aim and Objectives: This in vitro study was designed to comparatively evaluate the effect of five commercial mouth rinses on the micro hardness of a nanofilled resin based restorative material. Materials and Methods: Fifty specimens of resin composite material (Filtek Z350XT, 3M ESPE, St.Paul, MN USA) were prepared and immersed in artificial saliva for 24 h. The base line micro hardness of specimens was recorded using Vicker's micro hardness tester (MMT – X7 Matsuzawa, Japan). The specimens were randomly distributed into five groups, each containing 10 specimens (n=10) as follows – Group I Listerine (alcohol based), Group II Periogard (alcohol based), Group III Colgate plax (alcohol based), Group IV C- prev (alcohol free), Group V Hiora(alcohol free). The specimens were immersed in 20 ml of mouth rinses and incubated for 24 h at 37°C. The post immersion micro hardness values of the specimens were recorded and the data was tabulated for statistical analysis. Kruskal–Wallis test was used for inter group comparison followed by pair wise comparison of groups using Mann–Whitney U test. The level of significance was set at P=0.05. Results: Significant reduction in the mean VHN (Vicker's micro hardness number) was observed in all the groups after exposure to the tested mouth rinses (P<0.01) and the reduction in mean VHN values were as follows: Group I 12.09, Group II 3.42, Group II 1.51, Group IV 1.03, Group V 0.57. Inter group comparison showed statistically significant reduction in micro hardness in Groups I and II compared to all other groups with P<0.001. There was no significant difference between Groups III, IV and V. Conclusion: All the mouth rinses showed a reduction in the microhardness of nanofilled resin composite material with listerine (Group I) containing maximum amount of alcohol, showing highest reduction in micro hardness value. PMID:22876004

  3. Ultrasensitive and selective gold film-based detection of mercury (II) in tap water using a laser scanning confocal imaging-surface plasmon resonance system in real time.

    PubMed

    Zhang, Hongyan; Yang, Liquan; Zhou, Bingjiang; Liu, Weimin; Ge, Jiechao; Wu, Jiasheng; Wang, Ying; Wang, Pengfei

    2013-09-15

    An ultrasensitive and selective detection of mercury (II) was investigated using a laser scanning confocal imaging-surface plasmon resonance system (LSCI-SPR). The detection limit was as low as 0.01ng/ml for Hg(2+) ions in ultrapure and tap water based on a T-rich, single-stranded DNA (ssDNA)-modified gold film, which can be individually manipulated using specific T-Hg(2+)-T complex formation. The quenching intensity of the fluorescence images for rhodamine-labeled ssDNA fitted well with the changes in SPR. The changes varied with the Hg(2+) ion concentration, which is unaffected by the presence of other metal ions. The coefficients obtained for ultrapure and tap water were 0.99902 and 0.99512, respectively, for the linear part over a range of 0.01-100ng/ml. The results show that the double-effect sensor has potential for practical applications with ultra sensitivity and selectivity, especially in online or real-time monitoring of Hg(2+) ions pollution in tap water with the further improvement of portable LSCI-SPR instrument. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Fabrication and characterisation of ligand-functionalised ultrapure monodispersed metal nanoparticle nanoassemblies employing advanced gas deposition technique

    NASA Astrophysics Data System (ADS)

    Geremariam Welearegay, Tesfalem; Cindemir, Umut; Österlund, Lars; Ionescu, Radu

    2018-02-01

    Here, we report for the first time the fabrication of ligand-functionalised ultrapure monodispersed metal nanoparticles (Au, Cu, and Pt) from their pure metal precursors using the advanced gas deposition technique. The experimental conditions during nanoparticle formation were adjusted in order to obtain ultrafine isolated nanoparticles on different substrates. The morphology and surface analysis of the as-deposited metal nanoparticles were investigated using scanning electron microscopy, x-ray diffraction and Fourier transform infra-red spectroscopy, which demonstrated the formation of highly ordered pure crystalline nanoparticles with a relatively uniform size distribution of ∼10 nm (Au), ∼4 nm (Cu) and ∼3 nm (Pt), respectively. A broad range of organic ligands containing thiol or amine functional groups were attached to the nanoparticles to form continuous networks of nanoparticle-ligand nanoassemblies, which were characterised by scanning electron microscopy and x-ray photoelectron spectroscopy. The electrical resistance of the functional nanoassemblies deposited in the gap spacing of two microfabricated parallel Au electrodes patterned on silicon substrates ranged between tens of kΩ and tens of MΩ, which is suitable for use in many applications including (bio)chemical sensors, surface-enhanced Raman spectroscopy and molecular electronic rectifiers.

  5. Comparison of Antimicrobial Efficacy of Green Tea, Garlic with Lime, and Sodium Fluoride Mouth Rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans in Children: A Randomized Double-blind Controlled Clinical Trial

    PubMed Central

    Thomas, Ann; Habib, Rishika

    2017-01-01

    Introduction With greater awareness worldwide, the use of herbs and herbal products has increased to a large extent. Objective To evaluate and compare the antimicrobial efficacy of green tea, garlic with lime, and 0.05% sodium fluoride (NaF) mouth rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans. Materials and methods A total of 45 children aged 4 to 6 years with severe early childhood caries (S-ECC; based on decayed extracted filled [defs] score) were selected. Children were divided randomly into three equal groups and were asked to rinse with the prescribed mouth rinse once daily for 2 weeks after breakfast under supervision. A base-line and postrinsing nonstimulated whole salivary sample (2 mL) was collected and tested for the number of colony-forming units (CFUs). The data were statistically analyzed using Statistical Package for the Social Sciences (SPSS) version 16.0 software with one-way analysis of variance (ANOVA) and Tukey’s post hoc test. Results A statistically significant fall in colony count was found with the three mouth rinses in S. mutans (p < 0.001, p < 0.001) and Lactobacilli spp. (p < 0.001, p < 0.001), but not against C. albicans (p = 0.264, p = 0.264). On comparison, no statistically significant difference was found against S. mutans (p = 1, p = 0.554, p = 0.572), lactobacilli spp. (p = 0.884, p = 0.999, p = 0.819), and C. albicans (p = 0.999, p = 0.958, p = 0.983). Conclusion The findings of this study indicate that green tea and garlic with lime mouth rinse can be an economical alternative to NaF mouth rinse both for prevention and therapeutics. How to cite this article Thomas A, Thakur S, Habib R. Comparison of Antimicrobial Efficacy of Green Tea, Garlic with Lime, and Sodium Fluoride Mouth Rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans in Children: A Randomized Double-blind Controlled Clinical Trial. Int J Clin Pediatr Dent 2017;10(3):234-239. PMID:29104381

  6. Comparison of Antimicrobial Efficacy of Green Tea, Garlic with Lime, and Sodium Fluoride Mouth Rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans in Children: A Randomized Double-blind Controlled Clinical Trial.

    PubMed

    Thomas, Ann; Thakur, Sneha; Habib, Rishika

    2017-01-01

    With greater awareness worldwide, the use of herbs and herbal products has increased to a large extent. To evaluate and compare the antimicrobial efficacy of green tea, garlic with lime, and 0.05% sodium fluoride (NaF) mouth rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans. A total of 45 children aged 4 to 6 years with severe early childhood caries (S-ECC; based on decayed extracted filled [defs] score) were selected. Children were divided randomly into three equal groups and were asked to rinse with the prescribed mouth rinse once daily for 2 weeks after breakfast under supervision. A base-line and postrinsing nonstimulated whole salivary sample (2 mL) was collected and tested for the number of colony-forming units (CFUs). The data were statistically analyzed using Statistical Package for the Social Sciences (SPSS) version 16.0 software with one-way analysis of variance (ANOVA) and Tukey's post hoc test. A statistically significant fall in colony count was found with the three mouth rinses in S. mutans (p < 0.001, p < 0.001) and Lactobacilli spp. (p < 0.001, p < 0.001), but not against C. albicans (p = 0.264, p = 0.264). On comparison, no statistically significant difference was found against S. mutans (p = 1, p = 0.554, p = 0.572), lactobacilli spp. (p = 0.884, p = 0.999, p = 0.819), and C. albicans (p = 0.999, p = 0.958, p = 0.983). The findings of this study indicate that green tea and garlic with lime mouth rinse can be an economical alternative to NaF mouth rinse both for prevention and therapeutics. Thomas A, Thakur S, Habib R. Comparison of Antimicrobial Efficacy of Green Tea, Garlic with Lime, and Sodium Fluoride Mouth Rinses against Streptococcus mutans, Lactobacilli species, and Candida albicans in Children: A Randomized Double-blind Controlled Clinical Trial. Int J Clin Pediatr Dent 2017;10(3):234-239.

  7. Rust Contamination from Water Leaks in the Cosmic Dust Lab and Lunar and Meteorite Thin Sections Labs at Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Kent, J. J.; Berger, E. L.; Fries, M. D.; Bastien, R.; McCubbin, F. M.; Pace, L.; Righter, K.; Sutter, B.; Zeigler, R. A.; Zolensky, M.

    2017-01-01

    On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.

  8. Quantification of cell surface receptor expression in live tissue culture media using a dual-tracer stain and rinse approach

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochun; Sinha, Lagnojita; Singh, Aparna; Yang, Cynthia; Xiang, Jialing; Tichauer, Kenneth M.

    2015-03-01

    Immunofluorescence staining is a robust way to visualize the distribution of targeted biomolecules invasively in in fixed tissues and tissue culture. Despite the fact that these methods has been a well-established method in fixed tissue imaging for over 70 years, quantification of receptor concentration still simply assumes that the signal from the targeted fluorescent marker after incubation and sufficient rinsing is directly proportional to the concentration of targeted biomolecules, thus neglecting the experimental inconsistencies in incubation and rinsing procedures and assuming no, nonspecific binding of the fluorescent markers. This work presents the first imaging approach capable of quantifying the concentration of cell surface receptor on cancer cells grown in vitro based on compartment modeling in a nondestructive way. The approach utilizes a dual-tracer protocol where any non-specific retention or variability in incubation and rinsing of a receptor-targeted imaging agent is corrected by simultaneously imaging the retention of a chemically similar, "untargeted" imaging agent. Various different compartment models were used to analyze the data in order to find the optimal procedure for extracting estimates of epidermal growth factor receptor (EGFR) concentration (a receptor overexpressed in many cancers and a key target for emerging molecular therapies) in tissue cultures with varying concentrations of human glioma cells (U251). Preliminary results demonstrated a need to model nonspecific binding of both the targeted and untargeted imaging agents used. The approach could be used to carry out the first repeated measures of cell surface receptor dynamics during 3D tumor mass development, in addition to the receptor response to therapies.

  9. Aggregate exposure modelling of zinc pyrithione in rinse-off personal cleansing products using a person-orientated approach with market share refinement.

    PubMed

    Tozer, Sarah A; Kelly, Seamus; O'Mahony, Cian; Daly, E J; Nash, J F

    2015-09-01

    Realistic estimates of chemical aggregate exposure are needed to ensure consumer safety. As exposure estimates are a critical part of the equation used to calculate acceptable "safe levels" and conduct quantitative risk assessments, methods are needed to produce realistic exposure estimations. To this end, a probabilistic aggregate exposure model was developed to estimate consumer exposure from several rinse off personal cleansing products containing the anti-dandruff preservative zinc pyrithione. The model incorporates large habits and practices surveys, containing data on frequency of use, amount applied, co-use along with market share, and combines these data at the level of the individual based on subject demographics to better estimate exposure. The daily-applied exposure (i.e., amount applied to the skin) was 3.79 mg/kg/day for the 95th percentile consumer. The estimated internal dose for the 95th percentile exposure ranged from 0.01-1.29 μg/kg/day after accounting for retention following rinsing and dermal penetration of ZnPt. This probabilistic aggregate exposure model can be used in the human safety assessment of ingredients in multiple rinse-off technologies (e.g., shampoo, bar soap, body wash, and liquid hand soap). In addition, this model may be used in other situations where refined exposure assessment is required to support a chemical risk assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Role of warm saline mouth rinse in prevention of alveolar osteitis: a randomized controlled trial.

    PubMed

    Osunde, Otasowie Daniel; Bassey, Godwin Obi

    2015-01-01

    The present study was aimed at determining the role warm saline rinse in the prevention of alveolar osteitis following dental extractions. Apparently patients aged 16 and above who were referred to the Oral Surgery Clinic of our institution, with an indication for non-surgical extraction of pathologic teeth were prospectively and uniformly randomized into warm saline group and control. The experimental group (n = 80) were instructed to gargle 6 times daily with warm saline and no such instructions were given to the second group (n = 80) to serve as controls. Information on demographic, indications for extraction, and development of alveolar osteitis were obtained and analyzed. Comparative statistics were done using Pearson's chi square or Fisher's exact test as appropriate. A p value of less than 0.05 was considered significant. The demographic and other baseline parameters such as indications for extractions were comparable among the study groups (p > 0.05). The overall prevalence of alveolar osteitis was 13.7%. There was a statistical significant difference between the study groups with respect to development of alveolar osteitis (X2 = 15.00, df = 1, p = 0.001).The risk of development of alveolar osteitis was 4 times higher in the control group (OR = 4.33, P = 0.001). Warm saline mouth rinse instruction is beneficial in the prevention of development of alveolar osteitis after dental extractions.

  11. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children.

    PubMed

    Meadows, Emily; Le Saux, Nicole

    2004-11-01

    Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique.

  12. Prevention of bacteremia in dogs undergoing dental scaling by prior administration of oral clindamycin or chlorhexidine oral rinse.

    PubMed

    Bowersock, T L; Wu, C C; Inskeep, G A; Chester, S T

    2000-03-01

    Dogs with periodontitis were used to determine the efficacy of an oral regimen of clindamycin versus chlorhexidine acetate oral rinse in reducing the total number of bacteria and the incidence of bacteremia before and after dental scaling. Aerobic and anaerobic bacteria, isolated from blood and gingival swab cultures, were identified to genus using an automated system.

  13. Installation Assessment of Frankford Arsenal.

    DTIC Science & Technology

    1977-10-01

    sulfate , sulfuric acid , ac ’solution 40 Hot water bath 41 Nickel plate Nickel sulfate and chloride sulfuric acid , acid ...solution 42 Chromium Copper plate Copper sulfate and sulfuric acid , acid solution 11-14 TABLE 11-2 (continued) Tank No. Plating Process Use Contents...46 Water rinse Water 47 Water rinse Water 48 Water rinse Water 49 Acid Chromic acid , acetic acid , nickel sulfate and sulfuric

  14. Availability of tissue rinse liquid-based cytology for the rapid diagnosis of sentinel lymph node metastasis and improved bilateral detection by photodynamic eye camera.

    PubMed

    Kato, Hidenori; Ohba, Yoko; Yamazaki, Hiroyuki; Minobe, Shin-Ichiro; Sudo, Satoko; Todo, Yukiharu; Okamoto, Kazuhira; Yamashiro, Katsushige

    2015-08-01

    On sentinel lymph node navigation surgery for early invasive cervical cancers, to gain high sensitivity and specificity, the sentinel nodes should be detected bilaterally and pathological diagnosis should be sensitive to detect micrometastasis. To improve these problems, we tried tissue rinse liquid-based cytology and the photodynamic eye. From 2005 to 2013, 102 patients with Stage Ib1 uterine cervical cancer were subjected to sentinel lymph node navigation surgery with Technetium-99 m colloid and blue dye. For the recent 11 patients with whom bilateral sentinel node detection was not available, the photodynamic eye was selectively examined. The detected sentinel node was cut along the minor axis into 2 mm slices, soaked in 10 ml CytoRich red and then subjected to tissue rinse liquid-based cytology at the time of surgery. With the accumulation of 102 Ib1 patients subjected to sentinel lymph node navigation surgery, the bilateral sentinel node detection rate was 67.7%. The photodynamic eye was examined for the recent 11 patients who did not have bilateral signals. Out of the 11, 10 patients obtained bilateral signals successfully. During the period of examining the photodynamic eye, a total of 34 patients were subjected to sentinel lymph node navigation surgery. Thus, the overall bilateral detection rate increased to 97% in this subset. Two hundred and five lymph nodes were available as sentinel nodes. The sensitivity of tissue rinse liquid-based cytology was 91.7%, and the specificity was 100%. False positivity was 0% and false negativity was 8.3%. Detection failure was observed only with one micrometastasis and one case of isolated tumor cells. Combination of photodynamic eye detection and tissue rinse liquid-based cytology pathology can be a promising method for more rewarding sentinel node detection. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. The effect of nutrient media water purity on LIBS based identification of bacteria

    USDA-ARS?s Scientific Manuscript database

    Single pulse laser induced breakdown spectroscopy (LIBS) is used as the basis for discrimination between 3 genera of Gram-negative bacteria and 2 genera of gram-positive bacteria representing pathogenic threats commonly found in poultry processing rinse waters. Because LIBS-based discrimination reli...

  16. Mechanical properties and modeling of drug release from chlorhexidine-containing etch-and-rinse adhesives.

    PubMed

    Stanislawczuk, Rodrigo; Reis, Alessandra; Malaquias, Pamela; Pereira, Fabiane; Farago, Paulo Vitor; Meier, Marcia Margarete; Loguercio, Alessandro D

    2014-04-01

    To evaluate the effects of chlorhexidine (CHX) addition in different concentrations into simplified etch-and-rinse adhesives on the ultimate tensile strength (UTS), water sorption (WS), solubility (SO) and the rate of CHX release over time. We added CHX diacetate to Ambar [AM] (FGM) and XP Bond [XP] (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. For UTS (n=10 for each group), adhesive specimens were constructed in an hourglass shape metallic matrix with cross-sectional area of 0.8 mm(2). Half of specimens were tested after 24 h and the other half after 28 days of water storage in tension of 0.5 mm/min. For WS and SO (n=10 for each group), adhesive discs (5.8 mm×1.0 mm) were prepared into a mold. After desiccation, we weighed and stored the cured adhesive specimens in distilled water for evaluation of the WS, SO and the cumulative release of CHX over a 28-day period. For CHX release (n=10 for each group), spectrophotometric measurements of storage solution were performed to examine the release kinetics of CHX. We subjected data from each test to ANOVA and Tukey' test (α=0.05). XP Bond adhesive showed significantly more WS and SO and lower UTS than Ambar. In general, the addition of CHX did not alter WS, SO and UTS of the adhesives. XP showed a higher CHX release than AM (p<0.05) in all concentrations and the final amount of CHX release was directly proportional to the initial CHX concentration added to the adhesives. After 28 days of water storage, approximately 20% of CHX was released from XP and 8.0-12.0% from AM. Addition of CHX to commercial adhesive is a feasible method to provide a controlled release of CHX over time without jeopardizing WS, SO and UTS of the adhesives. Manufacturers should consider adding CHX to commercial adhesives to provide a controlled release of CHX over time. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. The effectiveness of a saline mouth rinse regimen and education programme on radiation-induced oral mucositis and quality of life in oral cavity cancer patients: A randomised controlled trial.

    PubMed

    Huang, B-S; Wu, S-C; Lin, C-Y; Fan, K-H; Chang, J T-C; Chen, S-C

    2018-03-01

    Radiation therapy (RT) and concurrent chemotherapy RT (CCRT) generate radiation-induced oral mucositis (OM) and lower quality of life (QOL). This study assessed the impact of a saline mouth rinse regimen and education programme on radiation-induced OM symptoms, and QOL in oral cavity cancer (OCC) patients receiving RT or CCRT. Ninety-one OCC patients were randomly divided into a group that received saline mouth rinses and an education programme and a control group that received standard care. OM symptoms and QOL were assessed with the WHO Oral Toxicity Scale, MSS-moo and UW-QOL. Data were collected at the first postoperative visit to the radiation department (T0) and at 4 weeks and 8 weeks after beginning RT or CCRT. Patients in both groups had significantly higher levels of physical and social-emotional QOL at 8 weeks after beginning RT or CCRT compared to the first visit. Patients in the saline rinse group had significantly better physical and social-emotional QOL as compared to the standard care group at 8 weeks. Radiation-induced OM symptoms and overall QOL were not different between the groups. We thus conclude the saline rinse and education programme promote better physical and social-emotional QOL in OCC patients receiving RT/CCRT. © 2018 John Wiley & Sons Ltd.

  18. New Technology for Oil/Water Emulsion Treatment: Phases I and II

    DTIC Science & Technology

    1998-05-15

    m.(Aŕ) Emulsions have long been of practical interest because of their extensive everyday applications. Emulsions are used in foods ( milk and...separating cream from milk . Valve-discharge centrifuges periodically discharge accumulated solids. Split-bowl centrifuges have a bowl that allows...fresh air. Call a physician. RVF CONTACT: Flush with water for 15 minutes. Call a physician. Wash thSroSghly with soap and rinse with water. Call

  19. Methylisothiazolinone in rinse-off products causes allergic contact dermatitis: a repeated open-application study.

    PubMed

    Yazar, K; Lundov, M D; Faurschou, A; Matura, M; Boman, A; Johansen, J D; Lidén, C

    2015-07-01

    In recent years, the prevalence of contact allergy to the preservative methylisothiazolinone (MI) has increased dramatically. Cosmetic products are one of the major sources of exposure. To examine whether allowed concentrations of MI in cosmetic rinse-off products have the potential to cause allergic contact dermatitis. Nineteen MI-allergic subjects and 19 controls without MI allergy applied two liquid hand soaps five times per day on areas of 5 × 10 cm(2) on the ventral side of their forearms. One soap contained 100 ppm MI, the maximum allowed concentration in cosmetics, and was used by 10 allergic subjects and all controls. Another liquid soap with 50 ppm MI was used by nine allergic subjects. As the negative control, all subjects used a similar soap that did not contain MI. The repeated open applications proceeded until a positive reaction occurred or up to 21 days. The study was conducted in a randomized and blinded fashion. Ten out of 10 MI-allergic subjects developed positive reactions to the soap with 100 ppm and seven out of nine reacted to the 50 ppm soap, while none of the 19 controls had a positive reaction during 21 days of application. No reactivity was seen to the soap without MI. The difference in reactivity to MI between MI-allergic subjects and controls was statistically significant (Fisher's exact test, P ˂ 0.0001). Rinse-off products preserved with 50 ppm MI or more are not safe for consumers. No safe level has yet been identified. © 2015 British Association of Dermatologists.

  20. [Prospective randomized study regarding the effect of the preoperative antibiotic and chlorhexidine rinse on wound healing after mandibular third molar surgery].

    PubMed

    Kaposvári, István; Körmöczi, Kinga; László, Zsuzsa Beáta; Oberna, Ferenc; Horváth, Ferenc; Joób-Fancsaly, Árpád

    2017-01-01

    The study compares the antibiotic prophylaxis combined with postoperative antibiotic therapy to preoperative chlorhexidine rinse combined with postoperative antibiotic therapy in preventing complications after surgical removal of a mandibular third molar. 71 healthy patients in four groups were enrolled in the study: I. prophylactic dose of 2000 mg of amoxicillin clavulanate, continued with amoxicillin clavulanate postoperatively; II. prophylactic dose of 600 mg of clindamycin, continued with clindamycin postoperatively; III. prophylactic chlorhexidin rinsing, continued randomized amoxicillin clavulanate or clindamycin postoperatively; IV. control, with clindamycin postoperatively. The pain was smaller in the prophylaxis groups. Alveolitis occurred only in the control group: 2 patients. Wound opening occurred in 22,2 % in group IV., 14,2 % in group II, 10 % in group I., 5 % in group III. We consider completing the indicated postoperative antibiotic prescription with antibiotic or antiseptic prophylaxis. Chlorhexidin prophylaxis could have the same positive effect. Orv. Hetil., 2017, 158(1), 13-19.

  1. Long-term bonding effectiveness of simplified etch-and-rinse adhesives to dentin after different surface pre-treatments

    PubMed Central

    Verma, Radhika; Singh, Udai Pratap; Tyagi, Shashi Prabha; Nagpal, Rajni; Manuja, Naveen

    2013-01-01

    Objective: To evaluate the effect of 2% chlorhexidine (CHX) and 30% proanthocyanidin (PA) application on the immediate and long-term bond strength of simplified etch-and-rinse adhesives to dentin. Materials and Methods: One hundred twenty extracted human molar teeth were ground to expose the flat dentin surface. The teeth were equally divided into six groups according to the adhesives used, either Tetric N Bond or Solobond M and pretreatments given either none, CHX, or PA. Composite cylinder was bonded to each specimen using the respective adhesive technique. Half the samples from each group (n = 10) were then tested immediately. The remaining samples were tested after 6 month storage in distilled water. Results: The mean bond strength of samples was not significantly different upon immediate testing being in the range of 8.4(±0.7) MPa. The bond strength fell dramatically in the control specimens after 6 month storage to around 4.7(±0.33) MPa, while the bond strength was maintained in the samples treated with both CHX and PA. Conclusion: Thirty percent PA was comparable to 2% CHX with respect to preservation of the resin dentin bond over 6 months. PMID:23956543

  2. Aberrant DNA methylation of tumor-related genes in oral rinse: a noninvasive method for detection of oral squamous cell carcinoma.

    PubMed

    Nagata, Satoshi; Hamada, Tomofumi; Yamada, Norishige; Yokoyama, Seiya; Kitamoto, Sho; Kanmura, Yuji; Nomura, Masahiro; Kamikawa, Yoshiaki; Yonezawa, Suguru; Sugihara, Kazumasa

    2012-09-01

    The early detection of oral squamous cell carcinoma (OSCC) is important, and a screening test with high sensitivity and specificity is urgently needed. Therefore, in this study, the authors investigated the methylation status of tumor-related genes with the objective of establishing a noninvasive method for the detection of OSCC. Oral rinse samples were obtained from 34 patients with OSCC and from 24 healthy individuals (controls). The methylation status of 13 genes was determined by using methylation-specific polymerase chain reaction analysis and was quantified using a microchip electrophoresis system. Promoter methylation in each participant was screened by receiver operating characteristic analysis, and the utility of each gene's methylation status, alone and in combination with other genes, was evaluated as a tool for oral cancer detection. Eight of the 13 genes had significantly higher levels of DNA methylation in samples from patients with OSCC than in controls. The genes E-cadherin (ECAD), transmembrane protein with epidermal growth factor-like and 2 follistatin-like domains 2 (TMEFF2), retinoic acid receptor beta (RARβ), and O-6 methylguanine DNA methyltransferase (MGMT) had high sensitivity (>75%) and specificity for the detection of oral cancer. OSCC was detected with 100% sensitivity and 87.5% specificity using a combination of ECAD, TMEFF2, RARβ, and MGMT and with 97.1% sensitivity and 91.7% specificity using a combination of ECAD, TMEFF2, and MGMT. The aberrant methylation of a combination of marker genes present in oral rinse samples was used to detect OSCC with >90% sensitivity and specificity. The detection of methylated marker genes from oral rinse samples has great potential for the noninvasive detection of OSCC. Copyright © 2012 American Cancer Society.

  3. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    PubMed Central

    Meadows, Emily; Le Saux, Nicole

    2004-01-01

    Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Results Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. Conclusions The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique. PMID:15518593

  4. Dietitians employed by health care facilities preferred a HACCP system over irradiation or chemical rinses for reducing risk of foodborne disease.

    PubMed

    Giamalva, J N; Redfern, M; Bailey, W C

    1998-08-01

    To survey dietitians in health care facilities about the acceptability of alternative meat and poultry processing methods designed to reduce the risk of foodborne disease and their willingness to pay for these processes. A geographically representative sample of 600 members of The American Dietetic Association who work in health care facilities. The response rate was 250 completed questionnaires from 592 eligible subjects (42%). A mail survey was used to gather information on the acceptability of a Hazard Analysis and Critical Control Point (HACCP) system, chemical rinses, and irradiation for increasing the safety of food. Discrete choice contingent valuation was used to determine the acceptability at current prices and at 5, 10, and 25 cents per pound above current prices. Logistic regression was used to estimate mean willingness to pay (the maximum amount respondents are willing to pay) for each process. A simultaneous equations regression model was used to estimate the effects of other variables on acceptability. Respondents expressed a high level of concern for food safety in health care facilities. The estimated mean willingness to pay was highest for a HACCP system and lowest for chemical rinses. The successful adoption of alternative methods to increase food safety depends on their acceptance by foodservice professionals. The professionals sampled were most accepting of a HACCP system, somewhat less accepting of irradiation, and least accepting of new chemical rinses. Poultry and beef processors and government agencies concerned with food safety may want to take into account the attitudes of foodservice professionals.

  5. Remineralization of eroded enamel by a NaF rinse containing a novel calcium phosphate agent in an in situ model: a pilot study

    PubMed Central

    Amaechi, Bennett T; Karthikeyan, Ramalingam; Mensinkai, Poornima K; Najibfard, Kaveh; Mackey, Allen C; Karlinsey, Robert L

    2010-01-01

    Purpose An in situ study evaluated the remineralization potential of 225 ppm fluoride (F) rinses with and without a calcium phosphate agent (TCP-Si-Ur) on eroded enamel. Methods 20 human patients participated in this IRB approved study. Enamel blocks extracted from 20 human molars were assigned to each of the three study phases (G1, G2, G3). Each block was eroded using 1% citric acid (pH = 2.5), with a slice cut from each block to establish baseline lesion parameters (ie, integrated mineral loss ΔZ, and lesion depth LD) using transverse microradiography (TMR). Participants and assigned blocks were randomly divided into three 28-day phases. The blocks were mounted into modified orthodontic brackets and bonded to the buccal surface of one of the subject’s mandibular molars. The appliance remained in the subject’s mouth for 28 days. Prior to each study phase, participants observed a one-week-washout period using a fluoride-free dentifrice. In each phase, participants brushed with the fluoride-free dentifrice for 1 min, followed by one of the following coded treatments: G1: 225 ppm F + 40 ppm TCP-Si-Ur rinse (1 min); G2: 225 ppm F rinse (1 min); G3: no rinse (saliva-only). After each phase, appliances were removed and specimens were analyzed using TMR. Results TMR data (ie, ΔZ and LD) revealed all three groups significantly remineralized eroded enamel (paired t-tests, P < 0.001). Net mineralization (% change in ΔZ, LD) were as follows (mean (std.dev): G1: 44.1 (22.6), 30.5 (27.0); G2: 30.0 (7.4), 29.4 (10.5); G3: 23.8 (16.4), 25.7 (15.5). Furthermore, G1 was found to cause significantly more remineralization than G2 (P = 0.039) and G3, (P = 0.002). Conclusion Mouthrinse containing 225 ppm F plus TCP-Si-Ur provided significantly greater remineralization relative to 225 ppm F only or saliva alone. PMID:23662086

  6. Oral fluoride levels 1 h after use of a sodium fluoride rinse: effect of sodium lauryl sulfate.

    PubMed

    Vogel, Gerald L; Schumacher, Gary E; Chow, Laurence C; Tenuta, Livia M A

    2015-01-01

    Increasing the concentration of free fluoride in oral fluids is an important goal in the use of topical fluoride agents. Although sodium lauryl sulfate (SLS) is a common dentifrice ingredient, the influence of this ion on plaque fluid and salivary fluid fluoride has not been examined. The purpose of this study was to investigate the effect of SLS on these parameters and to examine the effect of this ion on total (or whole) plaque fluoride, an important source of plaque fluid fluoride after a sufficient interval following fluoride administration, and on total salivary fluoride, a parameter often used as a surrogate measure of salivary fluid fluoride. Ten subjects accumulated plaque for 48 h before rinsing with a 12 mmol/l NaF (228 µg/g F) rinse containing or not containing 0.5% (w/w) SLS. SLS had no statistically significant effect on total plaque and total saliva fluoride but significantly increased salivary fluid and plaque fluid fluoride (by 147 and 205%, respectively). These results suggest that the nonfluoride components of topical agents can be manipulated to improve the fluoride release characteristics from oral fluoride reservoirs and that statistically significant change may be observed in plaque fluid and salivary fluid fluoride concentrations that may not be observed in total plaque and total saliva fluoride concentrations.

  7. Testing of the KRIA Ionizing Water Treatment System for Waters Contaminated with Diesel, PCBs, and Nutrients (Nitrogen Forms)

    DTIC Science & Technology

    2016-02-01

    superoxide treatment, presumably because the radioisotopes were solubilized and rinsed off the soil. The study hypothesized that the superoxide enhanced...reservoir, Blantyre Malawi. Physics and Chemistry of the Earth 28:1161-1164. Clean Water Team (CWT). 2004. Electrical Conductivity/Salinity Fact...number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) February 2016 2. REPORT TYPE Final report 3. DATES COVERED

  8. "Rinse and trickle": a protocol for TEM preparation and investigation of inorganic fibers from biological material.

    PubMed

    Vigliaturo, Ruggero; Capella, Silvana; Rinaudo, Caterina; Belluso, Elena

    2016-07-01

    The purpose of this work is to define a sample preparation protocol that allows inorganic fibers and particulate matter extracted from different biological samples to be characterized morphologically, crystallographically and chemically by transmission electron microscopy-energy dispersive spectroscopy (TEM-EDS). The method does not damage or create artifacts through chemical attacks of the target material. A fairly rapid specimen preparation is applied with the aim of performing as few steps as possible to transfer the withdrawn inorganic matter onto the TEM grid. The biological sample is previously digested chemically by NaClO. The salt is then removed through a series of centrifugation and rinse cycles in deionized water, thus drastically reducing the digestive power of the NaClO and concentrating the fibers for TEM analysis. The concept of equivalent hydrodynamic diameter is introduced to calculate the settling velocity during the centrifugation cycles. This technique is applicable to lung tissues and can be extended to a wide range of organic materials. The procedure does not appear to cause morphological damage to the fibers or modify their chemistry or degree of crystallinity. The extrapolated data can be used in interdisciplinary studies to understand the pathological effects caused by inorganic materials.

  9. INTERACTION OF LASER RADIATION WITH MATTER: Influence of Ca and Pb impurities on the bulk optical strength of ultrapure NaCl and KCl crystals

    NASA Astrophysics Data System (ADS)

    Vinogradov, An V.; Voszka, R.; Kovalev, Valerii I.; Faĭzullov, F. S.; Janszky, J.

    1987-06-01

    A significant increase (by a factor of about 3) of the bulk damage threshold in the case of interaction of CO2 laser radiation pulses with ultrapure NaCl and KCl crystals grown in a reactive atmosphere was observed on introduction of divalent metal ions Ca and Pb in concentrations of 10-5-10-6 mol/mol. Impurities were introduced in concentrations of 10-8-10-3 and 2×10-7-10-4 mol/mol into the melts of KCl and NaCl, respectively. The concentration of other impurities (including OH) did not exceed ~10-6 mol/mol. A physical model was developed to account for the observed dependence on the basis of an analogy between a system of colloidal particles and F centers in a crystal and a liquid-vapor system.

  10. An experimental study on the cavitation of water with dissolved gases

    NASA Astrophysics Data System (ADS)

    Li, Buxuan; Gu, Youwei; Chen, Min

    2017-12-01

    Cavitation inception is generally determined by the tensile strengths of liquids. Investigations on the tensile strength of water, which is essential in many fields, will help understand the promotion/prevention of cavitation and related applications in water. Previous experimental studies, however, vary in their conclusions about the value of tensile strength of water; the difference is commonly attributed to the existence of impurities in water. Dissolved gases, especially oxygen and nitrogen from the air, are one of the most common kinds of impurities in water. The influence of these gases on the tensile strength of water is still unclear. This study investigated the effects of dissolved gases on water cavitation through experiments. Cavitation in water is generated by acoustic method. Water samples are prepared with dissolved oxygen and nitrogen in different gas concentrations. Results show that under the same temperature, the tensile strength of water with dissolved oxygen or nitrogen decreases with increased gas concentration compared with that of ultrapure water. Under the same gas concentration and temperature, water with dissolved oxygen shows a lower tensile strength than that with dissolved nitrogen. Possible reasons of these results are also discussed.

  11. Environmental Consequences of Nanotechnologies: Nanoparticle Dispersion in Aqueous Media: SOP-T-1

    DTIC Science & Technology

    2015-02-01

    containing ice • Bath sonicator • Weighing dish (aluminum) • Stainless steel spatula • Analytical balance • Lab jack for lifting sample • Volumetric...balance and an aluminum dish, weigh an adequate mass of dry powder under a fume hood to achieve the desired concentration into ultrapure water (<T>, <R...0.025 0.5 0.05 1 0.5 10 1 20 2. Add ultra-pure water in a glass beaker with NP powder to /flask under fume hood (<T>, <R>). 3. Degas the bath

  12. Effect of Herbal and Fluoride Mouth Rinses on Streptococcus mutans and Dental Caries among 12–15-Year-Old School Children: A Randomized Controlled Trial

    PubMed Central

    Shenoy Panchmal, Ganesh; Kumar, Vijaya; Jodalli, Praveen S.; Sonde, Laxminarayan

    2017-01-01

    To assess and compare the effect of herbal and fluoride mouth rinses on Streptococcus mutans count and glucan synthesis by Streptococcus mutans and dental caries, a parallel group placebo controlled randomized trial was conducted among 240 schoolchildren (12–15 years old). Participants were randomly divided and allocated into Group I (0.2% fluoride group), Group II (herbal group), and Group III (placebo group). All received 10 ml of respective mouth rinses every fortnight for a period of one year. Intergroup and intragroup comparison were done for Streptococcus mutans count and glucan synthesis by Streptococcus mutans and dental caries. Streptococcus mutans count showed a statistically significant difference between Group I and Group III (p = 0.035) and also between Group II and Group III (p = 0.039). Glucan concentration levels showed a statistically significant difference (p = 0.024) between Group II and Group III at 12th month. Mean DMF scores showed no statistical difference between the three groups (p = 0.139). No difference in the level of significance was seen in the intention-to-treat and per-protocol analysis. The present study showed that both herbal and fluoride mouth rinses, when used fortnightly, were equally effective and could be recommended for use in school-based health education program to control dental caries. Trial registration number is CTRI/2015/08/006070. PMID:28352285

  13. MicroRNA-137 promoter methylation in oral rinses from patients with squamous cell carcinoma of the head and neck is associated with gender and body mass index.

    PubMed

    Langevin, Scott M; Stone, Roslyn A; Bunker, Clareann H; Grandis, Jennifer R; Sobol, Robert W; Taioli, Emanuela

    2010-05-01

    Head and neck cancer represents 3.3% of all new malignancies and 2.0% of cancer deaths in the USA, the majority of which are squamous in origin. The overall 5 year survival is 60% and worsens with increasing stage at diagnosis. Thus, novel biomarkers for early detection of squamous cell carcinoma of the head and neck (SCCHN) are needed. MicroRNA-137 (miR-137) plays a role in cell cycle control and seems to undergo promoter methylation in oral squamous cell carcinoma tissue. The main objectives of this study were to ascertain whether miR-137 promoter methylation is detectable in oral rinse samples, assess its association with SCCHN and identify potential risk factors for its occurrence. Oral rinse samples were collected from 99 SCCHN patients with no prior history of cancer and 99 cancer-free controls, frequency matched on gender; tumor tissue for 64 patients was also tested. Methylation of the miR-137 promoter, assessed using methylation-specific polymerase chain reaction, was detected in 21.2% oral rinses from SCCHN patients and 3.0% from controls [odds ratio (OR) = 4.80, 95% confidence interval (CI): 1.23-18.82]. Among cases, promoter methylation of miR-137 was associated with female gender (OR = 5.30, 95% CI: 1.20-23.44) and inversely associated with body mass index (BMI) (OR = 0.88, 95% CI: 0.77-0.99). Promoter methylation of miR-137 appears to be a relatively frequently detected event in oral rinse of SCCHN patients and may have future utility as a biomarker in DNA methylation panels. The observed associations with gender and BMI help to shed light on potential risk factors for an altered methylation state in SCCHN.

  14. Antimicrobial effect of electrolyzed oxidizing water against Escherichia coli O157:H7 and Listeria monocytogenes on fresh strawberries (Fragaria x ananassa).

    PubMed

    Udompijitkul, P; Daeschel, M A; Zhao, Y

    2007-11-01

    Antibacterial activity of electrolyzed oxidizing (EO) water prepared from 0.05% or 0.10% (w/v) sodium chloride (NaCl) solutions against indigenous bacteria associated with fresh strawberries (Fragaria x ananassa) was evaluated. The efficacy of EO water and sodium hypochlorite (NaOCl) solution in eliminating and controlling the growth of Listeria monocytogenes and Escherichia coli O157:H7 inoculated onto strawberries stored at 4 +/- 1 degrees C up to 15 d was investigated at exposure time of 1, 5, or 10 min. Posttreatment neutralization of fruit surfaces was also determined. More than 2 log(10) CFU/g reductions of aerobic mesophiles were obtained in fruits washed for 10 or 15 min in EO water prepared from 0.10% (w/v) NaCl solution. Bactericidal activity of the disinfectants against L. monocytogenes and E. coli O157:H7 was not affected by posttreatment neutralization, and increasing exposure time did not significantly increase the antibacterial efficacy against both pathogens. While washing fruit surfaces with distilled water resulted in 1.90 and 1.27 log(10) CFU/mL of rinse fluid reduction of L. monocytogenes and E. coli O157:H7, respectively, >/= 2.60 log(10) CFU/mL of rinse fluid reduction of L. monocytogenes and up to 2.35 and 3.12 log(10) CFU/mL of rinse fluid reduction of E. coli O157:H7 were observed on fruit surfaces washed with EO water and NaOCl solution, respectively. Listeria monocytogenes and E. coli O157:H7 populations decreased over storage regardless of prior treatment. However, EO water and aqueous NaOCl did not show higher antimicrobial potential than water treatment during refrigeration storage.

  15. A rapid method for the preparation of ultrapure, functional lysosomes using functionalized superparamagnetic iron oxide nanoparticles.

    PubMed

    Walker, Mathew W; Lloyd-Evans, Emyr

    2015-01-01

    Lysosomes are an emerging and increasingly important cellular organelle. With every passing year, more novel proteins and key cellular functions are associated with lysosomes. Despite this, the methodologies for their purification have largely remained unchanged since the days of their discovery. With little advancement in this area, it is no surprise that analysis of lysosomal function has been somewhat stymied, largely in part by the change in buoyant densities that occur under conditions where lysosomes accumulate macromolecules. Such phenotypes are often associated with the lysosomal storage diseases but are increasingly being observed under conditions where lysosomal proteins or, in some cases, cellular functions associated with lysosomal proteins are being manipulated. These altered lysosomes poise a problem to the classical methods to purify lysosomes that are reliant largely on their correct sedimentation by density gradient centrifugation. Building upon a technique developed by others to purify lysosomes magnetically, we have developed a unique assay using superparamagnetic iron oxide nanoparticles (SPIONs) to purify high yields of ultrapure functional lysosomes from multiple cell types including the lysosomal storage disorders. Here we describe this method in detail, including the rationale behind using SPIONs, the potential pitfalls that can be avoided and the potential functional assays these lysosomes can be used for. Finally we also summarize the other methodologies and the exact reasons why magnetic purification of lysosomes is now the method of choice for lysosomal researchers. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Hypermethylated ZNF582 and PAX1 genes in mouth rinse samples as biomarkers for oral dysplasia and oral cancer detection.

    PubMed

    Cheng, Shih-Jung; Chang, Chi-Feng; Ko, Hui-Hsin; Lee, Jang-Jaer; Chen, Hsin-Ming; Wang, Huei-Jen; Lin, Hsiao-Shan; Chiang, Chun-Pin

    2018-02-01

    Effective biomarkers for oral cancer screening are important for early diagnosis and treatment of oral cancer. Oral epithelial cell samples collected by mouth rinse were obtained from 65 normal control subjects, 108 patients with oral potentially malignant disorders, and 94 patients with oral squamous cell carcinoma (OSCC). Methylation levels of zinc-finger protein 582 (ZNF582) and paired-box 1 (PAX1) genes were quantified by real-time methylation-specific polymerase chain reaction after bisulfite conversion. An abrupt increase in methylated ZNF582 (ZNF582 m ) and PAX1 (PAX1 m ) levels and positive rates from mild dysplasia to moderate/severe dysplasia, indicating that both ZNF582 m and PAX1 m are effective biomarkers for differentiating moderate dysplasia or worse (MODY+) oral lesions. When ZNF582 m /PAX1 m tests were used for identifying MODY+ oral lesions, the sensitivity, specificity, and odds ratio (OR) were 0.65/0.64, 0.75/0.82, and 5.6/8.0, respectively. Hypermethylated ZNF582 and PAX1 genes in oral epithelial cells collected by mouth rinse are effective biomarkers for the detection of oral dysplasia and oral cancer. © 2017 Wiley Periodicals, Inc.

  17. Biofilm formation and control in a simulated spacecraft water system - Two-year results

    NASA Technical Reports Server (NTRS)

    Schultz, John R.; Taylor, Robert D.; Flanagan, David T.; Carr, Sandra E.; Bruce, Rebekah J.; Svoboda, Judy V.; Huls, M. H.; Sauer, Richard L.; Pierson, Duane L.

    1991-01-01

    The ability of iodine to maintain microbial water quality in a simulated spacecraft water system is being studied. An iodine level of about 2.0 mg/L is maintained by passing ultrapure influent water through an iodinated ion exchange resin. Six liters are withdrawn daily and the chemical and microbial quality of the water is monitored regularly. Stainless steel coupons used to monitor biofilm formation are being analyzed by culture methods, epifluorescence microscopy, and scanning electron microscopy. Results from the first two years of operation show a single episode of high bacterial colony counts in the iodinated system. This growth was apparently controlled by replacing the iodinated ion exchange resin. Scanning electron microscopy indicates that the iodine has limited but not completely eliminated the formation of biofilm during the first two years of operation. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

  18. Sage tea-thyme-peppermint hydrosol oral rinse reduces chemotherapy-induced oral mucositis: A randomized controlled pilot study.

    PubMed

    Mutluay Yayla, Ezgi; Izgu, Nur; Ozdemir, Leyla; Aslan Erdem, Sinem; Kartal, Murat

    2016-08-01

    This pilot study aimed to investigate the preventive effect of sage tea-thyme-peppermint hydrosol oral rinse used in conjunction with basic oral care on chemotherapy-induced oral mucositis. An open-label randomized controlled study. Two oncology hospitals in Ankara, Turkey. Patients receiving 5-fluorouracil-based chemotherapy regimens were divided into the intervention group (N=30) and control group (N=30). Basic oral care was prescribed to the control group, while the intervention group was prescribed sage tea-thyme-peppermint hydrosol in addition to basic oral care. All patients were called to assess their compliance with the study instructions on day 5 and 14. Oral mucositis was evaluated using an inspection method or by assessing oral cavity photos based on the World Health Organization oral toxicity scale on day 5 and 14. Most of the patients in the intervention group did not develop oral mucositis on day 5. In addition, the incidence of grade 1 oral mucositis was statistically lower in the intervention group (10%) than the control group (53.3%) on day 5. By day 14, the majority of patients in both the groups had grade 0 oral mucositis. Sage tea-thyme-peppermint hydrosol oral rinse has promising results in alleviating oral mucositis. This hydrosol can be recommended for clinical use as it is well tolerated and cost-effective. However, further randomized controlled trials are needed to support the study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. BPA qualtitative and quantitative assessment associated with orthodontic bonding in vivo.

    PubMed

    Kloukos, Dimitrios; Sifakakis, Iosif; Voutsa, Dimitra; Doulis, Ioannis; Eliades, George; Katsaros, Christos; Eliades, Theodore

    2015-08-01

    To assess the in vivo amount of BPA released from a visible light-cured orthodontic adhesive, immediately after bracket bonding. 20 orthodontic patients were recruited after obtaining informed consent. All patients received 24 orthodontic brackets in both dental arches. In Group A (11 patients), 25 ml of tap water were used for mouth rinsing, whereas in Group B (9 patients) a simulated mouth rinse formulation was used: a mixture of 20 ml de-ionized water plus 5 ml absolute ethanol. Rinsing solutions were collected before, immediately after placing the orthodontic appliances and after washing out the oral cavity and were then stored in glass tubes. Rinsing was performed in a single phase for 60s with the entire volume of each liquid. The BPA analysis was performed by gas chromatography-mass spectrometry. An increase in BPA concentration immediately after the 1st post-bonding rinse was observed, for both rinsing media, which was reduced after the 2nd post-bonding rinse. Water exhibited higher levels of BPA concentration than water/ethanol after 1st and 2nd post-bonding rinses. Two-way mixed Repeated Measures ANOVA showed that the primary null hypothesis declaring mean BPA concentration to be equal across rinsing medium and rinsing status was rejected (p-value <0.001). The main effects of the rinsing medium and status, as well as their interaction were found to be statistically significant (p-values 0.048, <0.001 and 0.011 respectively). A significant pattern of increase of BPA concentration, followed by a decrease that reached the initial values was observed. The amount of BPA was relatively low and far below the reference limits of tolerable daily intake. Copyright © 2015. Published by Elsevier Ltd.

  20. Microtensile bond strength of etch-and-rinse and self-etching adhesives to intrapulpal dentin after endodontic irrigation and setting of root canal sealer.

    PubMed

    Wattanawongpitak, Nipaporn; Nakajima, Masatoshi; Ikeda, Masaomi; Foxton, Richard M; Tagami, Junji

    2009-02-01

    To evaluate the effect of endodontic irrigation regimens and calcium hydroxide root canal sealer (Sealapex) on the microtensile bond strengths (muTBS) of dual-curing resin composite (Clearfil DC Core Automix) to the intrapulpal dentin. Forty standardized coronal-half root canal dentin specimens obtained from human premolars were divided into 4 groups: group A, no treatment (control); group B, Sealapex; group C, NaOCl/Sealapex; group D, EDTA/NaOCl/Sealapex. After 7 days of storage in 100% relative humidity, Sealapex was removed. Dentin surfaces were bonded with adhesives, either etch-and-rinse (Single Bond) or self-etching (Clearfil SE Bond), and built up with resin composite. The bonded specimens were trimmed into an hourglass shape with a 1-mm2 cross-sectional area for microtensile testing (n = 20). The muTBS to intrapulpal dentin was analyzed using two-way ANOVA and Dunnett's TC test. Two teeth of each group were prepared for micromorphological analysis of dentin surface. The root canal sealer with or without endodontic irrigation significantly affected the bond strengths of resin composite to intrapulpal dentin compared with the control group (p < 0.05). There were no significant differences in muTBS of each experimental group between etch-and-rinse and self-etching adhesives (p > 0.05). The dentin surface was covered with a mud-like material after sealer application for 7 days. The root canal sealer reduced the muTBS of dual-curing resin composite with etch-and-rinse and self-etching adhesive systems to intrapulpal dentin. Treatment with EDTA followed by NaOCI prior to obturation caused an additional reduction in muTBS of both adhesive systems to intrapulpal dentin.

  1. Sinus Rinsing and Neti Pots

    MedlinePlus

    ... that it contains distilled or sterile water. 2. Filter (if boiled, sterile, or distilled water not available) ... if no boiled or distilled water and no filter available) Disinfect: Learn how to disinfect your water ...

  2. Fourier transform infrared photoacoustic spectroscopy study of physicochemical interaction between human dentin and etch-&-rinse adhesives in a simulated moist bond technique.

    PubMed

    Ubaldini, Adriana L M; Baesso, Mauro L; Sehn, Elizandra; Sato, Francielle; Benetti, Ana R; Pascotto, Renata C

    2012-06-01

    The purpose of this study was to provide the physicochemical interactions at the interfaces between two commercial etch-&-rinse adhesives and human dentin in a simulated moist bond technique. Six dentin specimens were divided into two groups (n=3) according to the use of two different adhesive systems: (a) 2-hydroxyethylmethacrylate (HEMA) and 4-methacryloxyethyl trimellitate anhydrate (4-META), and (b) HEMA. The Fourier transform infrared photoacoustic spectroscopy was performed before and after dentin treatment with 37% phosphoric acid, with adhesive systems and also for the adhesive systems alone. Acid-conditioning resulted in a decalcification pattern. Adhesive treated spectra subtraction suggested the occurrence of chemical bonding to dentin expressed through modifications of the OH stretching peak (3340 cm(-1)) and symmetric CH stretching (2900 cm(-1)) for both adhesives spectra; a decrease of orthophosphate absorption band (1040 to 970 cm(-1)) for adhesive A and a better resolved complex band formation (1270 to 970 cm(-1)) for adhesive B were observed. These results suggested the occurrence of chemical bonding between sound human dentin and etch-&-rinse adhesives through a clinical typical condition.

  3. Modeling the photodegradation of emerging contaminants in waters by UV radiation and UV/H2O2 system.

    PubMed

    Benitez, F Javier; Acero, Juan L; Real, Francisco J; Roldan, Gloria; Rodriguez, Elena

    2013-01-01

    Five emerging contaminants (1-H-Benzotriazole, N,N-diethyl-m-toluamide or DEET, Chlorophene, 3-Methylindole, and Nortriptyline HCl), frequently found in surface waters and wastewaters, were selected to be photooxidized in several water matrices. Previous degradation experiments of these compounds individually dissolved in ultra pure water were performed by using UV radiation at 254 nm and the Fenton's reagent. These oxidation systems allowed the determination of the quantum yields and the rate constants for the radical reaction between each compound and hydroxyl radicals. Later, the simultaneous photodegradation of mixtures of the selected ECs in several types of water (ultrapure water, reservoir water, and two effluents from WWTPs) was carried out and a kinetic study was conducted. A model is proposed for the ECs elimination, and the theoretically calculated concentrations with this model agreed well with the experimental results obtained, which confirmed that it constitutes an excellent tool to predict the elimination of these compounds in waters.

  4. Development of a preprototype vapor compression distillation water recovery subsystem

    NASA Technical Reports Server (NTRS)

    Johnson, K. L.

    1978-01-01

    The activities involved in the design, development, and test of a preprototype vapor compression distillation water recovery subsystem are described. This subsystem, part of a larger regenerative life support evaluation system, is designed to recover usable water from urine, urinal rinse water, and concentrated shower and laundry brine collected from three space vehicle crewmen for a period of 180 days without resupply. Details of preliminary design and testing as well as component developments are included. Trade studies, considerations leading to concept selections, problems encountered, and test data are also presented. The rework of existing hardware, subsystem development including computer programs, assembly verification, and comprehensive baseline test results are discussed.

  5. Assessment of Envi-Carb™ as a passive sampler binding phase for acid herbicides without pH adjustment.

    PubMed

    Seen, Andrew; Bizeau, Oceane; Sadler, Lachlan; Jordan, Timothy; Nichols, David

    2014-05-01

    The graphitised carbon solid phase extraction (SPE) sorbent Envi-Carb has been used to fabricate glass fibre filter- Envi-Carb "sandwich" disks for use as a passive sampler for acid herbicides. Passive sampler uptake of a suite of herbicides, including the phenoxyacetic acid herbicides 4-chloro-o-tolyloxyacetic acid (MCPA), 2,4-dichlorophenoxyacetic acid (2,4-D) and 3,6-dichloro-2-methoxybenzoic acid (Dicamba), was achieved without pH adjustment, demonstrating for the first time a suitable binding phase for passive sampling of acid herbicides at neutral pH. Passive sampling experiments with Duck River (Tasmania, Australia) water spiked at 0.5 μg L(-1) herbicide concentration over a 7 d deployment period showed that sampling rates in Duck River water decreased for seven out of eight herbicides, and in the cases of 3,6-dichloro-2-pyridinecarboxylic acid (Clopyralid) and Dicamba no accumulation of the herbicides occurred in the Envi-Carb over the deployment period. Sampling rates for 4-amino-3,5,6-trichloro-2-pyridinecarboxylic acid (Picloram), 2,4-D and MCPA decreased to approximately 30% of the sampling rates in ultrapure water, whilst sampling rates for 2-(4,6-dimethylpyrimidin-2-ylcarbamoylsulfamoyl) benzoic acid, methyl ester (Sulfometuron-methyl) and 3,5,6-Trichloro-2-pyridinyloxyacetic acid (Triclopyr) were approximately 60% of the ultrapure water sampling rate. For methyl N-(2,6-dimethylphenyl)-N-(methoxyacetyl)-D-alaninate (Metalaxyl-M) there was little variation in sampling rate between passive sampling experiments in ultrapure water and Duck River water. SPE experiments undertaken with Envi-Carb disks using ultrapure water and filtered and unfiltered Duck River water showed that not only is adsorption onto particulate matter in Duck River water responsible for a reduction in herbicide sampling rate, but interactions of herbicides with dissolved or colloidal matter (matter able to pass through a 0.2 μm membrane filter) also reduces the herbicide sampling

  6. The substantivity of a number of oral hygiene products determined by the duration of effects on salivary bacteria.

    PubMed

    Elworthy, A; Greenman, J; Doherty, F M; Newcombe, R G; Addy, M

    1996-06-01

    The persistence of action, or substantivity, of antimicrobial agents in the mouth appears to be a major variable influencing plaque inhibition. Such substantivity can be assessed by measuring the duration and magnitude of suppression of salivary bacterial numbers produced by antimicrobial agents. Although this has been determined for some agents, there is little information on the substantivity of the numerous products which contain these and other antimicrobial agents. This study was commissioned on the basis that efficacy cannot be assumed merely because a product contains a known active agent. Nine formulations or products were chosen: 2 rinses containing chlorhexidine or C31G, 4 rinses containing cetylpyridinium chloride (CPC) (with and without fluoride and/or alcohol), a minus-CPC control rinse, and 2 toothpastes with and without stannous fluoride. Additionally, water was used as a placebo control. Twenty health dentate volunteers took part in this blind, 10 cell randomized, single rinse, cross-over study, which was balanced for carryover. Mouthrinses were 15 ml volumes and toothpastes 3 gm in 10 ml water slurries rinsed for 60 seconds. On the day of each study volunteers suspended oral hygiene habits and at approximately 9:00 a.m. rinsed with the allocated formulation. Unstimulated saliva samples were obtained immediately before and 30, 60, 180, 300, and 420 minutes after rinsing. The samples were immediately processed for total anaerobic bacterial counts. All rinses except water and the minus CPC control rinse produced significant falls in counts to 30 minutes. Of more relevance in this inter-treatment comparison-designed study, the C31G rinse showed significant substantivity compared to water only for 60 minutes. C31G was highly significantly less substantive than chlorhexidine from 30 minutes to 420 minutes. The CPC rinses were similar and significantly more substantive than their control rinse to between 180 and 300 minutes. The stannous fluoride and

  7. Benchmarking organic micropollutants in wastewater, recycled water and drinking water with in vitro bioassays.

    PubMed

    Escher, Beate I; Allinson, Mayumi; Altenburger, Rolf; Bain, Peter A; Balaguer, Patrick; Busch, Wibke; Crago, Jordan; Denslow, Nancy D; Dopp, Elke; Hilscherova, Klara; Humpage, Andrew R; Kumar, Anu; Grimaldi, Marina; Jayasinghe, B Sumith; Jarosova, Barbora; Jia, Ai; Makarov, Sergei; Maruya, Keith A; Medvedev, Alex; Mehinto, Alvine C; Mendez, Jamie E; Poulsen, Anita; Prochazka, Erik; Richard, Jessica; Schifferli, Andrea; Schlenk, Daniel; Scholz, Stefan; Shiraishi, Fujio; Snyder, Shane; Su, Guanyong; Tang, Janet Y M; van der Burg, Bart; van der Linden, Sander C; Werner, Inge; Westerheide, Sandy D; Wong, Chris K C; Yang, Min; Yeung, Bonnie H Y; Zhang, Xiaowei; Leusch, Frederic D L

    2014-01-01

    Thousands of organic micropollutants and their transformation products occur in water. Although often present at low concentrations, individual compounds contribute to mixture effects. Cell-based bioassays that target health-relevant biological endpoints may therefore complement chemical analysis for water quality assessment. The objective of this study was to evaluate cell-based bioassays for their suitability to benchmark water quality and to assess efficacy of water treatment processes. The selected bioassays cover relevant steps in the toxicity pathways including induction of xenobiotic metabolism, specific and reactive modes of toxic action, activation of adaptive stress response pathways and system responses. Twenty laboratories applied 103 unique in vitro bioassays to a common set of 10 water samples collected in Australia, including wastewater treatment plant effluent, two types of recycled water (reverse osmosis and ozonation/activated carbon filtration), stormwater, surface water, and drinking water. Sixty-five bioassays (63%) showed positive results in at least one sample, typically in wastewater treatment plant effluent, and only five (5%) were positive in the control (ultrapure water). Each water type had a characteristic bioanalytical profile with particular groups of toxicity pathways either consistently responsive or not responsive across test systems. The most responsive health-relevant endpoints were related to xenobiotic metabolism (pregnane X and aryl hydrocarbon receptors), hormone-mediated modes of action (mainly related to the estrogen, glucocorticoid, and antiandrogen activities), reactive modes of action (genotoxicity) and adaptive stress response pathway (oxidative stress response). This study has demonstrated that selected cell-based bioassays are suitable to benchmark water quality and it is recommended to use a purpose-tailored panel of bioassays for routine monitoring.

  8. Mouth rinsing with a carbohydrate solution does not influence cycle time trial performance in the heat.

    PubMed

    Watson, Phillip; Nichols, David; Cordery, Philip

    2014-09-01

    Ten endurance-trained males were recruited to examine the possible role of carbohydrate (CHO) receptors in the mouth influencing exercise performance in the heat. Volunteers completed an incremental test to exhaustion to determine peak oxygen uptake, a familiarisation trial, followed by 2 experimental trials. Trials consisted of a 1-h time trial undertaken in a climatic chamber maintained at 30 °C, 60% relative humidity. Immediately before, and at regular intervals throughout exercise, subjects ingested a bolus of water and then were provided with either a placebo (PLA) or a 6.4% glucose (CHO) solution to rinse in the mouth for 10 s before being expectorated. There was no difference in total work done between the PLA and CHO trials (758.8 ± 149.0 kJ; 762.6 ± 141.1 kJ; P = 0.951). Pacing was also similar, with no differences in power output apparent during the experimental trials (P = 0.546). Core temperature (P = 0.615), heart rate (P = 0.505), ratings of perceived exertion (P = 0.181), and perceived thermal stress (P = 0.416) were not influenced by the nature of the intervention. Blood glucose concentrations were similar during the CHO and PLA trials (P = 0.117). In contrast to the findings of several studies undertaken in temperate conditions, the present investigation failed to support role of oral sensing of CHO in influencing performance during prolonged exercise in warm conditions.

  9. Constitutive modeling and dynamic softening mechanism during hot deformation of an ultra-pure 17%Cr ferritic stainless steel stabilized with Nb

    NASA Astrophysics Data System (ADS)

    Gao, Fei; Liu, Zhenyu; Misra, R. D. K.; Liu, Haitao; Yu, Fuxiao

    2014-09-01

    The hot deformation behavior of an ultra-pure 17%Cr ferritic stainless steel was studied in the temperature range of 750-1000 °C and strain rates of 0.5 to 10 s-1 using isothermal hot compression tests in a thermomechanical simulator. The microstructural evolution was investigated using electron backscattered diffraction and transmission electron microscopy. A modified constitutive equation considering the effect of strain on material constant was developed, which predicted the flow stress for the deformation conditions studied, except at 950 °C in 1 s-1 and 900 °C in 10 s-1. Decreasing deformation temperature and increasing strain was beneficial in refining the microstructure. Decreasing deformation temperature, the in-grain shear bands appeared in the microstructure. It is suggested that the dynamic softening mechanism is closely related to deformation temperature. At low deformation temperature, dynamic recovery was major softening mechanism and no dynamic recrystallization occurred. At high deformation temperature, dynamic softening was explained in terms of efficient dynamic recovery and limited continuous dynamic recrystallization. A drop in the flow stress was not found due to very small fraction of new grains nucleated during dynamic recrystallization.

  10. Pramoxine

    MedlinePlus

    ... your hands. Clean the affected area with mild soap and warm water. Rinse thoroughly. Pat affected area ... your hands. Clean affected rectal area with mild soap and warm water. Rinse thoroughly. Gently dry by ...

  11. Ethanol wet-bonding technique sensitivity assessed by AFM.

    PubMed

    Osorio, E; Toledano, M; Aguilera, F S; Tay, F R; Osorio, R

    2010-11-01

    In ethanol wet bonding, water is replaced by ethanol to maintain dehydrated collagen matrices in an extended state to facilitate resin infiltration. Since short ethanol dehydration protocols may be ineffective, this study tested the null hypothesis that there are no differences in ethanol dehydration protocols for maintaining the surface roughness, fibril diameter, and interfibrillar spaces of acid-etched dentin. Polished human dentin surfaces were etched with phosphoric acid and water-rinsed. Tested protocols were: (1) water-rinse (control); (2) 100% ethanol-rinse (1-min); (3) 100% ethanol-rinse (5-min); and (4) progressive ethanol replacement (50-100%). Surface roughness, fibril diameter, and interfibrillar spaces were determined with atomic force microscopy and analyzed by one-way analysis of variance and the Student-Newman-Keuls test (α = 0.05). Dentin roughness and fibril diameter significantly decreased when 100% ethanol (1-5 min) was used for rinsing (p < 0.001). Absolute ethanol produced collapse and shrinkage of collagen fibrils. Ascending ethanol concentrations did not collapse the matrix and shrank the fibrils less than absolute ethanol-rinses.

  12. Design and development of an automated flow injection instrument for the determination of arsenic species in natural waters.

    PubMed

    Hanrahan, Grady; Fan, Tina K; Kantor, Melanie; Clark, Keith; Cardenas, Steven; Guillaume, Darrell W; Khachikian, Crist S

    2009-10-01

    The design and development of an automated flow injection instrument for the determination of arsenite [As(III)] and arsenate [As(V)] in natural waters is described. The instrument incorporates solenoid activated self-priming micropumps and electronic switching valves for controlling the fluidics of the system and a miniature charge-coupled device spectrometer operating in a graphical programming environment. The limits of detection were found to be 0.79 and 0.98 microM for As(III) and As(V), respectively, with linear range of 1-50 microM. Spiked ultrapure water samples were analyzed and recoveries were found to be 97%-101% for As(III) and 95%-99% for As(V), respectively. Future directions in terms of automation, optimization, and field deployment are discussed.

  13. Stability of ramipril in water, apple juice, and applesauce.

    PubMed

    Allen, L V; Stiles, M L; Prince, S J; McLaury, H J; Sylvestri, M F

    1995-11-01

    The stability of ramipril in water, in apple juice, and in applesauce was studied. The contents of a single capsule each of ramipril 1.25, 2.5, and 5 mg were mixed in glass beakers with 120 mL of deionized and filtered water, apple juice, or applesauce. Each mixture was apportioned into 10 120-mL amber polyethylene terephthalate (PET) containers. Five of the containers in each set were stored at 23 degrees C, and samples were taken at 0, 1, 2, 6, 12, and 24 hours. The other five containers were stored at 3 degrees C, and samples were taken at 4, 8, 12, 24, and 48 hours. The samples were analyzed for ramipril concentration by stability-indicating high-performance liquid chromatography (HPLC). The quantity of drug remaining in the PET container after "administration" was determined by mixing the contents of single 5-mg ramipril capsules with 60 mL of apple juice, pouring the mixture into a waste receptacle, rinsing the PET container three separate times with 10 mL of water, and analyzing the pooled fluid from these rinses for ramipril concentration by HPLC. Under no condition did the percentage of ramipril remaining drop below 90%. No peaks for degradation products appeared in the chromatograms. The mean +/- S.D. quantity of ramipril remaining in the PET containers after draining was 0.3 +/- 0.3% for the apple juice. Ramipril from 1.25-, 2.5-, and 5-mg capsules mixed in water, in apple juice, and in applesauce was stable for 24 hours at 23 degrees C and for 48 hours at 3 degrees C.

  14. METHOD OF IMPROVING CORROSION RESISTANCE OF ZIRCONIUM

    DOEpatents

    Shannon, D.W.

    1961-03-28

    An improved intermediate rinse for zirconium counteracts an anomalous deposit that often results in crevices and outof-the-way places when ordinary water is used to rinse away a strong fluoride etching solution designed to promote passivation of the metal. The intermediate rinse, which is used after the etching solution and before the water, is characterized by a complexing agent for fluoride ions such as aluminum or zirconium nitrates or chlorides.

  15. Single application of 4% dimeticone liquid gel versus two applications of 1% permethrin creme rinse for treatment of head louse infestation: a randomised controlled trial

    PubMed Central

    2013-01-01

    Background A previous study indicated that a single application of 4% dimeticone liquid gel was effective in treating head louse infestation. This study was designed to confirm this in comparison with two applications of 1% permethrin. Methods We have performed a single centre parallel group, randomised, controlled, open label, community based trial, with domiciliary visits, in Cambridgeshire, UK. Treatments were allocated through sealed instructions derived from a computer generated list. We enrolled 90 children and adults with confirmed head louse infestation analysed by intention to treat (80 per-protocol after 4 drop outs and 6 non-compliant). The comparison was between 4% dimeticone liquid gel applied once for 15 minutes and 1% permethrin creme rinse applied for 10 minutes, repeated after 7 days as per manufacturer’s directions. Evaluated by elimination of louse infestation after completion of treatment application regimen. Results Intention to treat comparison of a single dimeticone liquid gel treatment with two of permethrin gave success for 30/43 (69.8%) of the dimeticone liquid gel group and 7/47 (14.9%) of the permethrin creme rinse group (OR 13.19, 95% CI 4.69 to 37.07) (p < 0.001). Per protocol results were similar with 27/35 (77.1%) success for dimeticone versus 7/45 (15.6%) for permethrin. Analyses by household gave essentially similar outcomes. Conclusions The study showed one 15 minute application of 4% dimeticone liquid gel was superior to two applications of 1% permethrin creme rinse (p < 0.001). The low efficacy of permethrin suggests it should be withdrawn. Trial registration Current Controlled Trials ISRCTN88144046. PMID:23548062

  16. Quantitative structure property relationships for the adsorption of pharmaceuticals onto activated carbon.

    PubMed

    Dickenson, E R V; Drewes, J E

    2010-01-01

    Isotherms were determined for the adsorption of five pharmaceutical residues, primidone, carbamazepine, ibuprofen, naproxen and diclofenac, to Calgon Filtrasorb 300 powdered activated carbon (PAC). The sorption behavior was examined in ultra-pure and wastewater effluent organic matter (EfOM) matrices, where more sorption was observed in the ultra-pure water for PAC doses greater than 10 mg/L suggesting the presence of EfOM hinders the sorption of the pharmaceuticals to the PAC. Adsorption behaviors were described by the Freundlich isotherm model. Quantitative structure property relationships (QSPRs) in the form of polyparameter linear solvation energy relationships were developed for simulating the Freundlich adsorption capacity in both ultra-pure and EfOM matrices. The significant 3D-based descriptors for the QSPRs were the molar volume, polarizability and hydrogen-bond donor parameters.

  17. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, Jerald A.

    1997-01-01

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for 1) cleaning, developing or etching, 2) rinsing, and 3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material.

  18. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, J.A.

    1997-08-26

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for (1) cleaning, developing or etching, (2) rinsing, and (3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material. 5 figs.

  19. Purification of contaminated paddy fields by clean water irrigation over two decades.

    PubMed

    Tai, Yiping; Lu, Huanping; Li, Zhian; Zhuang, Ping; Zou, Bi; Xia, Hanping; Wang, Faming; Wang, Gang; Duan, Jun; Zhang, Jianxia

    2013-10-01

    Paddy fields near a mining site in north part of Guangdong Province, PR China, were severely contaminated by heavy metals as a result of wastewater irrigation from the tailing pond. The following clean water irrigation for 2 decades produced marked rinsing effect, especially on Pb and Zn. Paddy fields continuously irrigated with wastewater ever since mining started (50 years) had 1,050.0 mg kg−1 of Pb and 810.3 mg kg−1 of Zn for upper 20 cm soil, in comparison with 215.9 mg kg−1 of Pb and 525.4 mg kg−1 of Zn, respectively, with clean water irrigation for 20 years. Rinsing effect mainly occurred to a depth of upper 40 cm, of which the soil contained highest metals. Copper and Cd in the farmlands were also reduced due to clean water irrigation. Higher availability of Pb might partly account for more Pb transferred from the tailing pond to the farmland and also more Pb removal from the farmland as a result of clean water irrigation. Neither rice in the paddy field nor dense weeds in the uncultivated field largely took up the metals. However, they might contribute to activate metals differently, leading to a different purification extent. Rotation of rice and weed reduced metal retention in the farmland soil, in comparison with sole rice growth. Harvesting of rice grain (and partially rice stalk) only contributed small fraction of total amount of removed metal. In summary, heavy metal in paddy field resulting from irrigation of mining wastewater could be largely removed by clean water irrigation for sufficient time.

  20. 21 CFR 355.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... where the water supply contains 0 to 0.7 parts per million (ppm) fluoride ion. (i) Preventive treatment... rinse in a concentrated form to be mixed with water before using to result in the appropriate fluoride.... A fluoride treatment rinse prepared by adding the powder (a concentrated solid dosage form) to water...

  1. 21 CFR 355.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... where the water supply contains 0 to 0.7 parts per million (ppm) fluoride ion. (i) Preventive treatment... rinse in a concentrated form to be mixed with water before using to result in the appropriate fluoride.... A fluoride treatment rinse prepared by adding the powder (a concentrated solid dosage form) to water...

  2. 21 CFR 355.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... where the water supply contains 0 to 0.7 parts per million (ppm) fluoride ion. (i) Preventive treatment... rinse in a concentrated form to be mixed with water before using to result in the appropriate fluoride.... A fluoride treatment rinse prepared by adding the powder (a concentrated solid dosage form) to water...

  3. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  4. 40 CFR 420.96 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY Acid Pickling...) Sulfuric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire, coil. Subpart I Pollutant or... operations. (b) Hydrochloric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire, coil...

  5. Effect of natural aquatic humic substances on the photodegradation of estrone.

    PubMed

    Silva, Carla Patrícia; Lima, Diana L D; Groth, Milena B; Otero, Marta; Esteves, Valdemar I

    2016-02-01

    Photodegradation of estrone (E1) was investigated under simulated solar radiation in absence and presence of the different fractions of humic substances (HS), namely humic acids (HA), fulvic acids (FA) and XAD-4 fraction. The pseudo-first order photodegradation rate constants increased from 0.1137 h(-1), in ultrapure (MQ) water, to 0.1774, 0.1943 and 0.3109 h(-1), in presence of HA, FA and XAD-4, respectively. Half-life time decreased from 6.10 h in MQ water to 3.91, 3.57 and 2.23 h in presence of HA, FA and XAD-4, respectively. These results evidence the relevant photosensitizing effect of XAD-4 fraction of HS on the degradation of E1, which, to the best of our knowledge have never been studied. Photodegradation studies were also conducted in organic matter-rich environmental aquatic matrices, namely fresh, estuarine and waste water. After 2 h, photodegradation achieved values ranged between 35.6 and 57.1% in natural water samples, compared with 26.4% in ultrapure water. The higher photodegradation occurred in an estuarine water sample, known to be rich in XAD-4 fraction and poor in HA, indicating that not only the presence of organic matter, but also its type, are determinant in the E1 photodegradation rate. Finally, the use of sodium azide as singlet oxygen ((1)O2) scavenger during the phototransformation of E1 in ultrapure and in two wastewater samples allowed to conclude that (1)O2 has an important role in the E1 photodegradation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions.

    PubMed

    Iijima, Masahiro; Yuasa, Toshihiro; Endo, Kazuhiko; Muguruma, Takeshi; Ohno, Hiroki; Mizoguchi, Itaru

    2010-01-01

    This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss). Non ion implanted nickel-titanium wire (Neo Sentalloy) was used as control. The anodic corrosion behavior was examined by potentiodynamic polarization measurement. The surfaces of the specimens were examined with SEM. The elemental depth profiles were characterized by XPS. Neo Sentalloy Ionguard in artificial saliva and Butler F Mouthrinse (500 ppm) had a lower current density than Neo Sentalloy. In addition, breakdown potential of Neo Sentalloy Ionguard in Ora-Bliss (900 ppm) was much higher than that of Neo Sentalloy although both wires had similar corrosion potential in Ora-Bliss (450 and 900 ppm). The XPS results for Neo Sentalloy Ionguard suggested that the layers consisted of TiO(2) and TiN were present on the surface and the layers may improve the corrosion properties.

  7. 40 CFR 420.95 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY Acid Pickling... for existing sources. (a) Sulfuric acid (spent acid solutions and rinse waters)—(1) Rod, wire, and... pickling (spent acid solutions and rinse waters)—(1) Rod, wire, and coil. Subpart I Pollutant or pollutant...

  8. Polychlorinated Biphenyl Levels in the Saginaw Confined Disposal Facility during Disposal Operations, Fall 1987

    DTIC Science & Technology

    1991-01-01

    aluminum foil-lined caps. Prior to use, glass jars and jugs for storage of PCB samples were washed with soap and water, rinsed with tap water, rinsed...technique used in this study. Because differences in solids-liquid separation techniques result in varying amounts of microparticles and/or organic

  9. Effect of Green Coffee Bean Extract on Streptococcus mutans Count: A Randomised Control Trial

    PubMed Central

    Kaushik, Mamta; Roshni, Roshni; Reddy, Pallavi; Mehra, Neha; Jain, Vallari; Rana, Ritu

    2017-01-01

    Introduction Mouth rinses have been popularly used as a supplementary oral hygiene aid. A lot of commercially available mouth rinses possess few adverse effects, which has necessitated the search for alternative and herbal mouth rinses. Aim The aim of the study was to assess the effect of rinsing with green coffee bean extract in comparison with chlorhexidine mouthwash and sterile water on salivary Streptococcus mutans count. Materials and Methods A randomized parallel controlled clinical trial was planned and 45 subjects aged between 18-22 years were selected. The subjects were divided into three groups (n=15 in each group): Group A: Study group: 2% Green coffee bean extract, Group B: Positive control: 0.2% Chlorhexidine (CHX), Group C: Negative control: Sterile water. Group A subjects rinsed mouth with 5 ml of 2% Green coffee bean extract for one minute. Group B subjects rinsed mouth with 5 ml 0.2% CHX mouthwash for one minute. Group C subjects rinsed mouth with 5 ml of Sterile water for one minute twice daily for two weeks. Baseline samples (Pre rinse) were collected on day 1 and post rinsing saliva samples were collected after 14 days. The samples were cultured using Mitis Salivarius Agar enriched with Bacitracin and colonies were counted using a hand held digital colony counter. The statistical analysis was done using paired t-test, One-way variance ANOVA and Post-Hoc tests. Results The Green coffee bean extract group showed a statistical significant reduction in Streptococcus mutans colony count before and after intervention which was comparable with CHX group. Conclusion Green coffee bean extract as a mouthwash can be explored as a safe and effective alternative to CHX mouthwash. PMID:28658911

  10. Whole body cleaning agent containing N-acyltaurate

    NASA Technical Reports Server (NTRS)

    Lentsch, Steven E. (Inventor)

    1992-01-01

    The subject invention relates to a human cleansing agent particularly suitable for use in long duration spaceflight and to a method of bathing with the agent. The agent of the subject invention is in the form of a paste having a pH of 5.0 to 7.9 which comprises an acyltaurate, a skin conditioner, a hair conditioner, and a preservative. More specifically, it includes sodium N-coconut acid-N-methyl taurate, in combination with soybean lecithin, polyquaternium 16, and formalin. This particular combination satisfies the following objectives: (1) that it be usable with a minimum amount of water per shower (approximately 1 gallon); (2) that it be easily separated from the water for purposes of water reclamation; (3) that it be pH compatible with skin and hair; (4) that it rinse well in deionized water; (5) that it be mild to skin and eyes; (6) that it effectively clean both skin and hair; (7) that it be suitable for use in zero gravity; and (8) that it provide ease of combing of wet and dry hair. The method of the invention includes the steps of wetting the skin and hair with a small quantity of water, lathering the skin with the paste, rinsing the lather from the skin and hair with a small quantity of water to produce a rinse water containing the cleansing agent, defoaming the rinse water, and supplying the defoamed rinse water to a water reclamation unit for recycling the water. The novelty of the invention appears to lie in the particular formulation of the cleansing agent and its method of use which provide optimal results under the given constraints and objectives.

  11. Toxicological profile of ultrapure 2,2',3,4,4',5,5'-heptachlorbiphenyl (PCB 180) in adult rats.

    PubMed

    Viluksela, Matti; Heikkinen, Päivi; van der Ven, Leo T M; Rendel, Filip; Roos, Robert; Esteban, Javier; Korkalainen, Merja; Lensu, Sanna; Miettinen, Hanna M; Savolainen, Kari; Sankari, Satu; Lilienthal, Hellmuth; Adamsson, Annika; Toppari, Jorma; Herlin, Maria; Finnilä, Mikko; Tuukkanen, Juha; Leslie, Heather A; Hamers, Timo; Hamscher, Gerd; Al-Anati, Lauy; Stenius, Ulla; Dervola, Kine-Susann; Bogen, Inger-Lise; Fonnum, Frode; Andersson, Patrik L; Schrenk, Dieter; Halldin, Krister; Håkansson, Helen

    2014-01-01

    PCB 180 is a persistent non-dioxin-like polychlorinated biphenyl (NDL-PCB) abundantly present in food and the environment. Risk characterization of NDL-PCBs is confounded by the presence of highly potent dioxin-like impurities. We used ultrapure PCB 180 to characterize its toxicity profile in a 28-day repeat dose toxicity study in young adult rats extended to cover endocrine and behavioral effects. Using a loading dose/maintenance dose regimen, groups of 5 males and 5 females were given total doses of 0, 3, 10, 30, 100, 300, 1000 or 1700 mg PCB 180/kg body weight by gavage. Dose-responses were analyzed using benchmark dose modeling based on dose and adipose tissue PCB concentrations. Body weight gain was retarded at 1700 mg/kg during loading dosing, but recovered thereafter. The most sensitive endpoint of toxicity that was used for risk characterization was altered open field behavior in females; i.e. increased activity and distance moved in the inner zone of an open field suggesting altered emotional responses to unfamiliar environment and impaired behavioral inhibition. Other dose-dependent changes included decreased serum thyroid hormones with associated histopathological changes, altered tissue retinoid levels, decreased hematocrit and hemoglobin, decreased follicle stimulating hormone and luteinizing hormone levels in males and increased expression of DNA damage markers in liver of females. Dose-dependent hypertrophy of zona fasciculata cells was observed in adrenals suggesting activation of cortex. There were gender differences in sensitivity and toxicity profiles were partly different in males and females. PCB 180 adipose tissue concentrations were clearly above the general human population levels, but close to the levels in highly exposed populations. The results demonstrate a distinct toxicological profile of PCB 180 with lack of dioxin-like properties required for assignment of WHO toxic equivalency factor. However, PCB 180 shares several toxicological

  12. Clinical Efficacy of a Specifically Targeted Antimicrobial Peptide Mouth Rinse: Targeted Elimination of Streptococcus mutans and Prevention of Demineralization

    PubMed Central

    Sullivan, R.; Santarpia, P.; Lavender, S.; Gittins, E.; Liu, Z.; Anderson, M.H.; He, J.; Shi, W.; Eckert, R.

    2011-01-01

    Background/Aims Streptococcus mutans, the major etiological agent of dental caries, has a measurable impact on domestic and global health care costs. Though persistent in the oral cavity despite conventional oral hygiene, S. mutans can be excluded from intact oral biofilms through competitive exclusion by other microorganisms. This suggests that therapies capable of selectively eliminating S. mutans while limiting the damage to the normal oral flora might be effective long-term interventions to fight cariogenesis. To meet this challenge, we designed C16G2, a novel synthetic specifically targeted antimicrobial peptide with specificity for S. mutans. C16G2 consists of a S. mutans-selective ‘targeting region’ comprised of a fragment from S. mutans competence stimulation peptide (CSP) conjoined to a ‘killing region’ consisting of a broad-spectrum antimicrobial peptide (G2). In vitro studies have indicated that C16G2 has robust efficacy and selectivity for S. mutans, and not other oral bacteria, and affects targeted bacteria within seconds of contact. Methods In the present study, we evaluated C16G2 for clinical utility in vitro, followed by a pilot efficacy study to examine the impact of a 0.04% (w/v) C16G2 rinse in an intra-oral remineralization/demineralization model. Results and Conclusions C16G2 rinse usage was associated with reductions in plaque and salivary S. mutans, lactic acid production, and enamel demineralization. The impact on total plaque bacteria was minimal. These results suggest that C16G2 is effective against S. mutans in vivo and should be evaluated further in the clinic. PMID:21860239

  13. Running performance and thermal sensation in the heat are improved with menthol mouth rinse but not ice slurry ingestion.

    PubMed

    Stevens, C J; Thoseby, B; Sculley, D V; Callister, R; Taylor, L; Dascombe, B J

    2016-10-01

    The purpose of this study was to compare the effects of a cooling strategy designed to predominately lower thermal state with a strategy designed to lower thermal sensation on endurance running performance and physiology in the heat. Eleven moderately trained male runners completed familiarization and three randomized, crossover 5-km running time trials on a non-motorized treadmill in hot conditions (33 °C). The trials included ice slurry ingestion before exercise (ICE), menthol mouth rinse during exercise (MEN), and no intervention (CON). Running performance was significantly improved with MEN (25.3 ± 3.5 min; P = 0.01), but not ICE (26.3 ± 3.2 min; P = 0.45) when compared with CON (26.0 ± 3.4 min). Rectal temperature was significantly decreased with ICE (by 0.3 ± 0.2 °C; P < 0.01), which persisted for 2 km of the run and MEN significantly decreased perceived thermal sensation (between 4 and 5 km) and ventilation (between 1 and 2 km) during the time trial. End-exercise blood prolactin concentration was elevated with MEN compared with CON (by 25.1 ± 24.4 ng/mL; P = 0.02). The data demonstrate that a change in the perception of thermal sensation during exercise from menthol mouth rinse was associated with improved endurance running performance in the heat. Ice slurry ingestion reduced core temperature but did not decrease thermal sensation during exercise or improve running performance. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Degradation of propyl paraben by activated persulfate using iron-containing magnetic carbon xerogels: investigation of water matrix and process synergy effects.

    PubMed

    Metheniti, Maria Evangelia; Frontistis, Zacharias; Ribeiro, Rui S; Silva, Adrián M T; Faria, Joaquim L; Gomes, Helder T; Mantzavinos, Dionissios

    2017-10-06

    An advanced oxidation process comprising an iron-containing magnetic carbon xerogel (CX/Fe) and persulfate was tested for the degradation of propyl paraben (PP), a contaminant of emerging concern, in various water matrices. Moreover, the effect of 20 kHz ultrasound or light irradiation on process performance was evaluated. The pseudo-first order degradation rate of PP was found to increase with increasing SPS concentration (25-500 mg/L) and decreasing PP concentration (1690-420 μg/L) and solution pH (9-3). Furthermore, the effect of water matrix on kinetics was detrimental depending on the complexity (i.e., wastewater, river water, bottled water) and the concentration of matrix constituents (i.e., humic acid, chloride, bicarbonate). The simultaneous use of CX/Fe and ultrasound as persulfate activators resulted in a synergistic effect, with the level of synergy (between 35 and 50%) depending on the water matrix. Conversely, coupling CX/Fe with simulated solar or UVA irradiation resulted in a cumulative effect in experiments performed in ultrapure water.

  15. Influence of pre- and post-usage flushing frequencies on bacterial water quality of non-touch water fittings.

    PubMed

    Suchomel, Miranda; Diab-Elschahawi, Magda; Kundi, Michael; Assadian, Ojan

    2013-08-30

    Non-touch fittings have been reported to be susceptible for Pseudomonas aeruginosa accumulation. A number of factors may contribute to this, including the frequency of usage, duration of water stagnation, or presence of plastic materials. Programmable non-touch fittings are appearing which allow regular automated post-flushing with cold water to prevent water stagnation. However, the ideal duration of post-flushing is unknown as well as the effect of pre-rinsing with cold water before use. Eight non-touch fittings with brass valve blocks were mounted on a mobile test sink and connected to the same central water pipe source, differing only in presence or absence of water connection pipes, length of connection pipe, frequency of usage, and time intervals for pre- and post-usage water flush. The total bacteria colony-forming unit (cfu) counts were obtained by the spread plate technique. Low frequency of water use in combination with a long stagnating water column resulted in high bacterial cfu counts. Post-usage flushing for 2 seconds did not differ from no flushing. Flushing for 10 seconds with cold water after use or 30 seconds flush before use were both the most effective measures to prevent non-touch fittings from biofilm formation over a period of 20 weeks. Further improvements in water fitting technology could possibly solve the problem of bacterial water contamination in health care settings.

  16. [Influence of long-term water storage on the physical and chemical properties of four different dental cements].

    PubMed

    Xu, Xiaodong; Meng, Xiangfeng

    2014-11-01

    To evaluate and compare the physical and chemical properties of four different dental cements under long-term water storage. A glass-ionomer cement (A:Fuji I), a resin reinforced glass-ionomer (B: Fuji Plus), a self-adhesive resin cement (C:G-Cem), and an etch & rinse resin cement (D: Duolink) were taken as samples. According to ISO 4049, water sorption and solubility of four resin cements under different storage times (1 week, 1, 3, 6 and 12 months) were calculated (n = 5), meanwhile their surface Knoop micro hardness values were measured. Surface cracks were detected on sample B and C after 12 months. Sample A was fragmentized after 6 months. Sample B showed significantly lower surface hardness after 12 months than it did after the first 24 hours of water storage (P < 0.05). Sample D showed significantly lower water sorption than other cements did at all exam time point. The highest water sorption values were observed in Sample D after 1 month [(40.8±2.5) µg/mm(3)], in Sample B after 3 months [(551.3±22.5) µg/mm(3)], in Sample C after 12 months [(147.5±8.3) µg/mm(3)]. The highest solubility values were detected in Sample B after 3 months [(105.3±10.5) µg/mm(3)], in Sample C after 12 months [(79.3 ± 6.2) µg/mm(3)], and in Sample D after 12 months [(23.9 ± 6.9) µg/mm(3)]. Among the four types of cements, the etch & rinse resin cement showed the best stability of physical and chemical properties under long-term water storage.

  17. Stability Characterization of Quinazoline Derivative BG1188 by Optical Methods

    NASA Astrophysics Data System (ADS)

    Militaru, Andra; Smarandache, Adriana; Mahamoud, Abdallah; Damian, Victor; Ganea, Paul; Alibert, Sandrine; Pagès, Jean-Marie; Pascu, Mihail-Lucian

    2011-08-01

    3-[2-(dimethylamino)ethyl]-6-nitroquinazolin-4(3H)-one, labeled BG1188, is a new synthesized compound, out of a series of quinazoline derivatives developed to fight the multidrug resistance of antibiotics acquired by bacteria. A characterization of the BG1188 powder was made using FTIR spectra in order to evidence the functional groups in the medicine's molecule. The ultraviolet-visible (UV-Vis) absorption spectra were used to study the stability of the BG1188 solutions in two solvents and at different temperatures. BG1188 concentration in ultrapure water was varied between 2×10-3 M (stock solution) and 10-6 M. The concentration recommended by higher activity on bacteria was 10-3 M. For the same reason, this was the utilized concentration of BG1188 in dimethyl sulfoxide (DMSO). Time stability was characterized by comparing the time evolution of the UV-Vis absorption spectra of the BG1188 solutions in ultrapure de-ionized water or in DMSO. The spectra were recorded daily for about 4 months after the preparation for the BG1188 solutions in ultrapure water. Generally, samples are stable within the experimental errors at concentrations higher than 10-5 M, but the stability time interval may vary from 119 days at 10-4 M to 34 days at 10-5 M. Time evolution of the absorption spectra at 10-3 M in ultrapure water shows reproducibility within the measuring errors (±1.045%) for time intervals up to 1032 hours (more than 40 days) after preparation. On the other hand, BG1188 solutions in DMSO may be considered unstable because the absorption spectra modify in terms of peak shapes and intensities, indicating that the samples exhibit modifications immediately after preparation. Regardless the solvent used, some aggregation phenomena took place and wire-like aggregates were observed in all the solutions with the naked eye. These aggregates were analyzed, tentatively, using optical microscopy and FTIR.

  18. Efficacy of home washing methods in controlling surface microbial contamination on fresh produce.

    PubMed

    Kilonzo-Nthenge, Agnes; Chen, Fur-Chi; Godwin, Sandria L

    2006-02-01

    Much effort has been focused on sanitation of fresh produce at the commercial level; however, few options are available to the consumer. The purpose of this study was to determine the efficacy of different cleaning methods in reducing bacterial contamination on fresh produce in a home setting. Lettuce, broccoli, apples, and tomatoes were inoculated with Listeria innocua and then subjected to combinations of the following cleaning procedures: (i) soak for 2 min in tap water, Veggie Wash solution, 5% vinegar solution, or 13% lemon solution and (ii) rinse under running tap water, rinse and rub under running tap water, brush under running tap water, or wipe with wet/dry paper towel. Presoaking in water before rinsing significantly reduced bacteria in apples, tomatoes, and lettuce, but not in broccoli. Wiping apples and tomatoes with wet or dry paper towel showed lower bacterial reductions compared with soaking and rinsing procedures. Blossom ends of apples were more contaminated than the surface after soaking and rinsing; similar results were observed between flower section and stem of broccoli. Reductions of L. innocua in both tomatoes and apples (2.01 to 2.89 log CFU/g) were more than in lettuce and broccoli (1.41 to 1.88 log CFU/g) when subjected to same washing procedures. Reductions of surface contamination of lettuce after soaking in lemon or vinegar solutions were not significantly different (P > 0.05) from lettuce soaking in cold tap water. Therefore, educators and extension workers might consider it appropriate to instruct consumers to rub or brush fresh produce under cold running tap water before consumption.

  19. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) of sodium peroxide is then added to the cup. The bomb is assembled and ignition is conducted in the usual fashion. (d) After the bomb has cooled, it is rinsed thoroughly with distilled water and disassembled. The top of the bomb is rinsed into a 250-milliliter beaker with distilled water. The beaker is...

  20. The effect of dimethyl sulfoxide (DMSO) on dentin bonding and nanoleakage of etch-and-rinse adhesives.

    PubMed

    Tjäderhane, Leo; Mehtälä, Pekka; Scaffa, Polliana; Vidal, Cristina; Pääkkönen, Virve; Breschi, Lorenzo; Hebling, Josimeri; Tay, Franklin R; Nascimento, Fabio D; Pashley, David H; Carrilho, Marcela R

    2013-10-01

    The objective was to examine the effect of a solvent dimethyl sulfoxide (DMSO) on resin-dentin bond durability, as well as potential functional mechanisms behind the effect. Microtensile bond strength (μTBS) was evaluated in extracted human teeth in two separate experiments. Dentin specimens were acid-etched and assigned to pre-treatment with 0.5mM (0.004%) DMSO as additional primer for 30s and to controls with water pre-treatment. Two-step etch-and-rinse adhesive (Scotchbond 1XT, 3M ESPE) was applied and resin composite build-ups were created. Specimens were immediately tested for μTBS or stored in artificial saliva for 6 and 12 months prior to testing. Additional immediate and 6-month specimens were examined for interfacial nanoleakage analysis under SEM. Matrix metalloproteinase (MMP) inhibition by DMSO was examined with gelatin zymography. Demineralized dentin disks were incubated in 100% DMSO to observe the optical clearing effect. The use of 0.5mM DMSO had no effect on immediate bond strength or nanoleakage. In controls, μTBS decreased significantly after storage, but increased significantly in DMSO-treated group. The control group had significantly lower μTBS than DMSO-group after 6 and 12 months. DMSO also eliminated the increase in nanoleakage seen in controls. 5% and higher DMSO concentrations significantly inhibited the gelatinases. DMSO induced optical clearing effect demonstrating collagen dissociation. DMSO as a solvent may be useful in improving the preservation of long-term dentin-adhesive bond strength. The effect may relate to dentinal enzyme inhibition or improved wetting of collagen by adhesives. The collagen dissociation required much higher DMSO concentrations than the 0.5mM DMSO used for bonding. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  1. Rinse, Reuse and Scream

    ERIC Educational Resources Information Center

    Sutley, Jane

    2009-01-01

    The author of this article describes how her eighth grade art students heighten their awareness of differences between their public self and their inner self by: manipulating water bottles to create sculptural self-portraits; constructing armatures of the generic person in "The Scream" by Edward Munch; finding and collecting examples of images and…

  2. Influence of post-treatment strategies on the properties of activated chars from broiler manure.

    PubMed

    Lima, Isabel M; Boykin, Debbie L; Thomas Klasson, K; Uchimiya, Minori

    2014-01-01

    There are a myriad of carbonaceous precursors that can be used advantageously to produce activated carbons or chars, due to their low cost, availability and intrinsic properties. Because of the nature of the raw material, production of granular activated chars from broiler manure results in a significant ash fraction. This study was conducted to determine the influence of several pre- and post-treatment strategies in various physicochemical and adsorptive properties of the resulting activated chars. Pelletized samples of broiler litter and cake were pyrolyzed at 700 °C for 1h followed by a 45 min steam activation at 800 °C at different water flow rates from 1 to 5 mL min(-1). For each activation strategy, samples were either water-rinsed or acid-washed and rinsed or used as is (no acid wash/rinse). Activated char's physicochemical and adsorptive properties towards copper ions were selectively affected by both pre- and post-treatments. Percent ash reduction after either rinsing or acid washing ranged from 1.1 to 15.1% but washed activated chars were still alkaline with pH ranging from 8.4 to 9.1. Acid washing or water rinsing had no significant effect in the ability of the activated char to adsorb copper ions, however it significantly affected surface area, pH, ash content and carbon content. Instead, manure type (litter versus cake) and the activation water flow rate were determining factors in copper ion adsorption which ranged from 38 mg g(-1) to 104 mg g(-1) of activated char. Moreover, strong positive correlations were found between copper uptake and concentration of certain elements in the activated char such as phosphorous, sulfur, calcium and sodium. Rinsing could suffice as a post treatment strategy for ash reduction since no significant differences in the carbon properties were observed between rinsed and acid wash treatments. Published by Elsevier Ltd.

  3. Effect of sunlight exposure on the release of intentionally and/or non-intentionally added substances from polyethylene terephthalate (PET) bottles into water: chemical analysis and in vitro toxicity.

    PubMed

    Bach, Cristina; Dauchy, Xavier; Severin, Isabelle; Munoz, Jean-François; Etienne, Serge; Chagnon, Marie-Christine

    2014-11-01

    The effect of sunlight exposure on chemical migration into PET-bottled waters was investigated. Bottled waters were exposed to natural sunlight for 2, 6 and 10 days. Migration was dependent on the type of water. Formaldehyde, acetaldehyde and Sb migration increased with sunlight exposure in ultrapure water. In carbonated waters, carbon dioxide promoted migration and only formaldehyde increased slightly due to sunlight. Since no aldehydes were detected in non-carbonated waters, we conclude that sunlight exposure has no effect. Concerning Sb, its migration levels were higher in carbonated waters. No unpredictable NIAS were identified in PET-bottled water extracts. Cyto-genotoxicity (Ames and micronucleus assays) and potential endocrine disruption effects (transcriptional-reporter gene assays) were checked in bottled water extracts using bacteria (Salmonella typhimurium) and human cell lines (HepG2 and MDA-MB453-kb2). PET-bottled water extracts did not induce any toxic effects (cyto-genotoxicity, estrogenic or anti-androgenic activity) in vitro at relevant consumer-exposure levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. EFFECT OF AN ADDITIONAL HYDROPHILIC VERSUS HYDROPHOBIC COAT ON THE QUALITY OF DENTINAL SEALING PROVIDED BY TWO-STEP ETCH-AND-RINSE ADHESIVES

    PubMed Central

    Silva, Safira Marques de Andrade; Carrilho, Marcela Rocha de Oliveira; Marquezini, Luiz; Garcia, Fernanda Cristina Pimentel; Manso, Adriana Pigozzo; Alves, Marcelo Corrêa; de Carvalho, Ricardo Marins

    2009-01-01

    Objective: To test the hypothesis that the quality of the dentinal sealing provided by two-step etch-and-rinse adhesives cannot be altered by the addition of an extra layer of the respective adhesive or the application of a more hydrophobic, non-solvated resin. Material and Methods: full-crown preparations were acid-etched with phosphoric acid for 15 s and bonded with Adper Single Bond (3M ESPE), Excite DSC (Ivoclar/Vivadent) or Prime & Bond NT (Dentsply). The adhesives were used according to the manufacturers' instructions (control groups) or after application to dentin they were a) covered with an extra coat of each respective system or b) coated with a non-solvated bonding agent (Adper Scotchbond Multi-Purpose Adhesive, 3M ESPE). Fluid flow rate was measured before and after dentin surfaces were acid-etched and bonded with adhesives. Results: None of the adhesives or experimental treatments was capable to block completely the fluid transudation across the treated dentin. Application of an extra coat of the adhesive did not reduce the fluid flow rate of adhesive-bonded dentin (p>0.05). Conversely, the application of a more hydrophobic non-solvated resin resulted in significant reductions in the fluid flow rate (p<0.05) for all tested adhesives. Conclusions: The quality of the dentinal sealing provided by etch-and-rinse adhesives can be significantly improved by the application of a more hydrophobic, non-solvated bonding agent. PMID:19466248

  5. Endotoxin contamination and control in surface water sources and a drinking water treatment plant in Beijing, China.

    PubMed

    Can, Zhang; Wenjun, Liu; Wen, Sun; Minglu, Zhang; Lingjia, Qian; Cuiping, Li; Fang, Tian

    2013-07-01

    In this paper, endotoxin contamination was determined in treated water following each unit of a drinking water treatment plant (WTP) in Beijing, China and its source water (SW) from a long water diversion channel (Shijiazhuang-Beijing) originating from four reservoirs in Hebei province, China. The total-endotoxin activities in SW ranged from 21 to 41 EU/ml at five selected cross sections of the diversion channel. The total-endotoxin in raw water of the WTP ranged from 11 to 16 EU/ml due to dilution and pretreatment during water transportation from Tuancheng Lake to the WTP, and finished water of the WTP ranged from 4 to 10 EU/ml, showing a 49% decrease following the full-scale treatment process at the WTP. Compared with the 31% removal of free-endotoxin, the WTP removed up to 71% of bound-endotoxin in raw water. The traditional treatment processes (coagulation, sedimentation and filtration) in the WTP removed substantial amounts of total-endotoxin (up to 63%), while endotoxin activities increased after granular activated carbon (GAC) adsorption and chlorination. The total-endotoxin in the actual water was composed of free-endotoxin and bound-endotoxin (endotoxin aggregates, bacteria-bound endotoxins and particle-attached endotoxins). The endotoxin aggregates, bacteria-bound endotoxins and particle-attached endotoxins co-exist as suspended particles in water, and only the bacteria-bound endotoxins were correlated with bacterial cells suspended in water. The particle distribution of endotoxin aggregates in ultrapure water was also tested and the results showed that the majority (64-89%) of endotoxin aggregates had diameters <2 μm. The endotoxin contamination and control in treated water following each unit of the WTP processes and its SW from reservoirs are discussed and compared with regard to bacterial cell counts and particle characteristics, which were dependent, to a certain extent, on different flow rates and turbulence of the water environments. Copyright

  6. A prospective clinical evaluation of the effects of chlorhexidine, warm saline mouth washes and microbial growth on intraoral sutures.

    PubMed

    Fomete, B; Saheeb, B D; Obiadazie, A C

    2015-06-01

    Post operative care of sutured wound is important after surgery. Sutured wounds within the oral cavity are kept clean through frequent rinses with either normal saline, chlorhexidine mouth rinses, hydrogen peroxide diluted with saline, or fresh tap water. The patients were randomised into 3 groups (A, B and C). The container used had 34 chlorhexidine, 34 warm saline and 32 warm water mouth rinses. The latter served as control. All selected patients had scaling and polishing done preoperatively when needed. All participants in each group did not receive antibiotics but received analgesics (paracetamol 1 g 8 h for 5 days,). There were 49 females and 51 males, in the age range between 18 and 50 years. Microorganisms were found to grow on sutures with streptococcus viridians predominating followed by staphylococcus epidermides. The effects of chlorhexidine, warm saline and warm tap water mouth washes were not statistically significant. Chlorhexidine, warm salt water and warm tap water averagely produced the same number of colony forming units of bacteria, which shows that the three different mouth washes are equally effective as post-operative mouth rinses after oral surgery.

  7. The effect of oxidizing water on metallic restorations in the mouth: in vitro reduction behavior of oxidizing water.

    PubMed

    Nishida, T

    1997-03-01

    Mouth-rinsing with oxydized water which contains electrolytically generated chlorine is known to hinder dental plaque formation and growth, but it also accelerates the deterioration of metallic restorations in the mouth. The present work consists of an in vitro study to elucidate the electrochemical reactions involved in the reduction of oxydized water on dental alloys through a systematic investigation of the potentiostatic polarization behavior of dental alloy electrodes. The five dental alloys selected for investigation were gold alloy, gold alloy containing platinum, silver-palladium-gold alloy, conventional amalgam and high copper amalgam. The corrosion potentials of all dental alloy electrodes were shown to be more noble in oxydized water than in 0.1N sodium chloride solution. The potential differences between the corrosion potentials were relatively small in the case of amalgam electrodes. The polarization curves for all of the dental alloy electrodes in oxydized water revealed reduction currents of chlorine, hypochlorous acid, dissolved oxygen and oxonium ion. The reduction of chlorine and hypochlorous acid started at a more noble potential than that of dissolved oxygen. The dental alloys studied, except the amalgams, did not dissolve excessively at the corrosion potentials in oxydized water.

  8. Migration through soil of organic solutes in an oil-shale process water

    USGS Publications Warehouse

    Leenheer, J.A.; Stuber, H.A.

    1981-01-01

    The migration through soil of organic solutes in an oil-shale process water (retort water) was studied by using soil columns and analyzing leachates for various organic constituents. Retort water extracted significant quantities of organic anions leached from ammonium-saturated-soil organic matter, and a distilled-water rinse, which followed retort-water leaching, released additional organic acids from the soil. After being corrected for organic constitutents extracted from soil by retort water, dissolved-organic-carbon fractionation analyses of effluent fractions showed that the order of increasing affinity of six organic compound classes for the soil was as follows: hydrophilic neutrals nearly equal to hydrophilic acids, followed by the sequence of hydrophobic acids, hydrophilic bases, hydrophobic bases, and hydrophobic neutrals. Liquid-chromatographic analysis of the aromatic amines in the hydrophobic- and hydrophilic-base fractions showed that the relative order of the rates of migration through the soil column was the same as the order of migration on a reversed-phase, octadecylsilica liquid-chromatographic column.

  9. Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin.

    PubMed

    Singh, Payal; Nagpal, Rajni; Singh, Udai Pratap

    2017-08-01

    This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups ( n = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA), and post hoc Tukey's test. At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only ( p = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall. Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

  10. Investigation of Stainless Steel Corrosion in Ultrahigh-Purity Water and Steam Systems by Surface Analytical Techniques

    NASA Astrophysics Data System (ADS)

    Dong, Xia; Iacocca, Ronald G.; Bustard, Bethany L.; Kemp, Craig A. J.

    2010-02-01

    Stainless steel pipes with different degrees of rouging and a Teflon®-coated rupture disc with severe corrosion were thoroughly investigated by combining multiple surface analytical techniques. The surface roughness and iron oxide layer thickness increase with increasing rouge severity, and the chromium oxide layer coexists with the iron oxide layer in samples with various degrees of rouging. Unlike the rouging observed for stainless steel pipes, the fast degradation of the rupture disc was caused by a crevice corrosion environment created by perforations in the protective Teflon coating. This failure analysis clearly shows the highly corrosive nature of ultrapure water used in the manufacture of pharmaceutical products, and demonstrates some of the unexpected corrosion mechanisms that can be encountered in these environments.

  11. Neutralizing salivary pH by mouthwashes after an acidic challenge.

    PubMed

    Dehghan, Mojdeh; Tantbirojn, Daranee; Kymer-Davis, Emily; Stewart, Colette W; Zhang, Yanhui H; Versluis, Antheunis; Garcia-Godoy, Franklin

    2017-05-01

    The aim of the present study was to test the neutralizing effect of mouthwashes on salivary pH after an acidic challenge. Twelve participants were recruited for three visits, one morning per week. Resting saliva was collected at baseline and after 2-min swishing with 20 mL orange juice as an acidic challenge. Participants then rinsed their mouth for 30 s with 20 mL water (control), an over-the-counter mouthwash (Listerine), or a two-step mouthwash, randomly assigned for each visit. Saliva was collected immediately, 15, and 45 min after rinsing. The pH values of the collected saliva were measured and analyzed with anova, followed by Student-Newman-Keuls post-hoc test (significance level: 0.05). Orange juice significantly lowered salivary pH. Immediately after rinsing, Listerine and water brought pH back to baseline values, with the pH significantly higher in the Listerine group. The two-step mouthwash raised pH significantly higher than Listerine and water, and higher than the baseline value. Salivary pH returned to baseline and was not significantly different among groups at 15 and 45 min post-rinsing. Mouth rinsing after an acidic challenge increased salivary pH. The tested mouthwashes raised pH higher than water. Mouthwashes with a neutralizing effect can potentially reduce tooth erosion from acid exposure. © 2015 Wiley Publishing Asia Pty Ltd.

  12. FPGA-based digital signal processing for the next generation radio astronomy instruments: ultra-pure sideband separation and polarization detection

    NASA Astrophysics Data System (ADS)

    Alvear, Andrés.; Finger, Ricardo; Fuentes, Roberto; Sapunar, Raúl; Geelen, Tom; Curotto, Franco; Rodríguez, Rafael; Monasterio, David; Reyes, Nicolás.; Mena, Patricio; Bronfman, Leonardo

    2016-07-01

    Field Programmable Gate Arrays (FPGAs) capacity and Analog to Digital Converters (ADCs) speed have largely increased in the last decade. Nowadays we can find one million or more logic blocks (slices) as well as several thousand arithmetic units (ALUs/DSP) available on a single FPGA chip. We can also commercially procure ADC chips reaching 10 GSPS, with 8 bits resolution or more. This unprecedented power of computing hardware has allowed the digitalization of signal processes traditionally performed by analog components. In radio astronomy, the clearest example has been the development of digital sideband separating receivers which, by replacing the IF hybrid and calibrating the system imbalances, have exhibited a sideband rejection above 40dB; this is 20 to 30dB higher than traditional analog sideband separating (2SB) receivers. In Rodriguez et al.,1 and Finger et al.,2 we have demonstrated very high digital sideband separation at 3mm and 1mm wavelengths, using laboratory setups. We here show the first implementation of such technique with a 3mm receiver integrated into a telescope, where the calibration was performed by quasi-optical injection of the test tone in front of the Cassegrain antenna. We also reported progress in digital polarization synthesis, particularly in the implementation of a calibrated Digital Ortho-Mode Transducer (DOMT) based on the Morgan et al. proof of concept.3 They showed off- line synthesis of polarization with isolation higher than 40dB. We plan to implement a digital polarimeter in a real-time FPGA-based (ROACH-2) platform, to show ultra-pure polarization isolation in a non-stop integrating spectrometer.

  13. Production of H2 from aluminium/water reaction and its potential for CO2 methanation

    NASA Astrophysics Data System (ADS)

    Khai Phung, Khor; Sethupathi, Sumathi; Siang Piao, Chai

    2018-04-01

    Carbon dioxide (CO2) is a natural gas that presents in excess in the atmosphere. Owing to its ability to cause global warming, capturing and conversion of CO2 have attracted much attention worldwide. CO2 methanation using hydrogen (H2) is believed to be a promising route for CO2 removal. In the present work, H2 is produced using aluminum-water reaction and tested for its ability to convert CO2 to methane (CH4). Different type of water i.e. tap water, distilled water, deionized water and ultrapure water, concentration of sodium hydroxide (NaOH) (0.2 M to 1.0 M) and particle size of aluminum (45 m to 500 μm) were varied as parameter study. It was found that the highest yield of H2 was obtained using distilled water, 1.0 M of NaOH and 45μm particle size of aluminium. However, the highest yield of methane was achieved using a moderate and progressive H2 production (distilled water, 0.6 M of NaOH and 45 μm particle size of aluminium) which allowed sufficient time for H2 to react with CO2. It was concluded that 1130 ml of H2 can produce about 560 ppm of CH4 within 25 min of batch reaction using nickel catalyst.

  14. [Effect of three aging challenges on the bonding stability of resin-dentin interface using an etch-and-rinse adhesive].

    PubMed

    Xu, Shuai; Zhang, Ling; Li, Fang; Zhou, Wei; Chen, Yujiang; Chen, Jihua

    2014-06-01

    To systematically investigate the aging effect of thermocycling, water storage and bacteria aggression on the stability of resin-dentin bonds. Forty molars were sectioned perpendicularly to the axis of the teeth to expose the middle-coronal dentin surfaces. The dentin surfaces were then treated with Single Bond 2 and made a core build-up. According to random digits table, the bonding specimens were divided into four groups (n = 10) as follows: immediate control group, aging group with thermocycling for 5 000 times, aging group with artificial saliva storage for 6 months and aging group with bacteria aggression for 14 days. The specimens in each group were then subjected to microtensile bond strengths (µTBS) testing and nanoleakage evaluation respectively. After aging treatments, the three aging groups showed significantly lower µTBS than the immediate control group [(44.24 ± 12.75) MPa, P < 0.05]. The immediate control group also showed the lowest value of nanoleakage. The µTBS of aging group with bacteria aggression [(25.53 ± 7.39) MPa] was significantly lower than those of the other aging groups with artificial saliva storage[(29.72 ± 6.51) MPa] and thermocycling [(31.92 ± 11.87) MPa, P < 0.05]. There were no differences in the nanoleakage values among the three aging groups (P > 0.05). All the aging treatments with artificial saliva storage, thermocycling and bacteria aggression could accelerate the degradation of bonding interfaces between an etch-and-rinse adhesive and dentin. Bacteria aggression showed the most impairing effect on the stability of resin-dentin bonds.

  15. Ultrafast quantitation of six quinolones in water samples by second-order capillary electrophoresis data modeling with multivariate curve resolution-alternating least squares.

    PubMed

    Alcaráz, Mirta R; Vera-Candioti, Luciana; Culzoni, María J; Goicoechea, Héctor C

    2014-04-01

    This paper presents the development of a capillary electrophoresis method with diode array detector coupled to multivariate curve resolution-alternating least squares (MCR-ALS) to conduct the resolution and quantitation of a mixture of six quinolones in the presence of several unexpected components. Overlapping of time profiles between analytes and water matrix interferences were mathematically solved by data modeling with the well-known MCR-ALS algorithm. With the aim of overcoming the drawback originated by two compounds with similar spectra, a special strategy was implemented to model the complete electropherogram instead of dividing the data in the region as usually performed in previous works. The method was first applied to quantitate analytes in standard mixtures which were randomly prepared in ultrapure water. Then, tap water samples spiked with several interferences were analyzed. Recoveries between 76.7 and 125 % and limits of detection between 5 and 18 μg L(-1) were achieved.

  16. 40 CFR 421.336 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....000 499.500 (d) SiCl4 purification wet air pollution control. PSNS for the Primary Zirconium and....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.800 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  17. 40 CFR 421.332 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... times. (d) SiCl4 purification wet air pollution control. BPT Limitations for the Primary Zirconium and....600 307.600 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from... Within the range of 7.5 to 10.0. (r) Leaching rinse water from zirconium alloy production. BPT...

  18. 40 CFR 421.333 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 2.387 1.108 Nickel 4.688 3.154 Ammonia (as N) 1,136.000 499.500 (d) SiCl4 purification wet air....674 5.835 Ammonia (as N) 2,102.000 895.000 (q) Leaching rinse water from zirconium metal production... Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy production. BAT...

  19. 40 CFR 421.332 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... times. (d) SiCl4 purification wet air pollution control. BPT Limitations for the Primary Zirconium and....600 307.600 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from... Within the range of 7.5 to 10.0. (r) Leaching rinse water from zirconium alloy production. BPT...

  20. 40 CFR 421.332 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... times. (d) SiCl4 purification wet air pollution control. BPT Limitations for the Primary Zirconium and....600 307.600 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from... Within the range of 7.5 to 10.0. (r) Leaching rinse water from zirconium alloy production. BPT...

  1. 40 CFR 421.336 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....000 499.500 (d) SiCl4 purification wet air pollution control. PSNS for the Primary Zirconium and....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.800 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  2. 40 CFR 421.336 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....000 499.500 (d) SiCl4 purification wet air pollution control. PSNS for the Primary Zirconium and....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.800 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  3. 40 CFR 421.332 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... times. (d) SiCl4 purification wet air pollution control. BPT Limitations for the Primary Zirconium and....600 307.600 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from... Within the range of 7.5 to 10.0. (r) Leaching rinse water from zirconium alloy production. BPT...

  4. 40 CFR 421.336 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....000 499.500 (d) SiCl4 purification wet air pollution control. PSNS for the Primary Zirconium and....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.800 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  5. 40 CFR 421.336 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....000 499.500 (d) SiCl4 purification wet air pollution control. PSNS for the Primary Zirconium and....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.800 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  6. 40 CFR 421.332 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... times. (d) SiCl4 purification wet air pollution control. BPT Limitations for the Primary Zirconium and....600 307.600 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from... Within the range of 7.5 to 10.0. (r) Leaching rinse water from zirconium alloy production. BPT...

  7. 40 CFR 421.333 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 2.387 1.108 Nickel 4.688 3.154 Ammonia (as N) 1,136.000 499.500 (d) SiCl4 purification wet air....674 5.835 Ammonia (as N) 2,102.000 895.000 (q) Leaching rinse water from zirconium metal production... Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy production. BAT...

  8. Extraction of diatoms from (cotton) clothing for forensic comparisons.

    PubMed

    Uitdehaag, Stefan; Dragutinovic, Aleksandar; Kuiper, Irene

    2010-07-15

    Diatoms in clothing can be used to determine contact with surface water and contact with a specific water source, which can help link suspects to crime scenes. However, for the study of diatoms it is imperative that they are first extracted from the clothing under investigation. In this study we tested three methods for extracting diatoms from cotton clothing: rinsing with water (RW), rinsing with ethanol (RE) and the dissolution of cotton with nitric and sulphuric acid (DI). The DI method produced the highest average yield and can be used to determine contact with water. The RE method extracted reproducible numbers of diatoms from two different T-shirts and the resulting species compositions were similar to their relevant reference water samples. Therefore, we present rinsing with ethanol as an effective extraction method for the qualitative and quantitative analysis of diatoms in (cotton) clothing. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, John; McCreight, Dan J.

    This project was undertaken to develop and demonstrate on a pilot scale the use of electro-osmotic transport to increase the efficiency of textiles wet processing operations. In particular, we sought to develop a means of rinsing textiles to remove material entrapped between the individual fibers that constitute a yarn. Material trapped within the yarn is slow to exchange with rinse water flowing primarily in the open weave are abetween the yarns. The application of an external field (strength, 5-50 kV /m) requires only a few volts for most fabric thicknesses. This field is sufficient to promote a rapid exchange ofmore » material to enhance rinsing and reduce the water required for rinsing from about 20 kg/kg-fabric to 3-6 kg/kg-fabric. We successfully developed technical and economic models of application of the process to the rinsing of many materials of industrial importance, including dyes, tints, chemicals, detergents and dye electrolytes. We demonstrated the process on a pilot plant scale using a translator designed in cooperation with Milliken and Company (Spartanburg, SC).« less

  10. 27 CFR 30.45 - Withdrawal gauge for packages.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... thorough mixing of the rinse water and the spirits and before return of the spirits to the rinsed packages... returned to the packages. In the case of metal packages the tare established at the time of filling may be...

  11. Biofilm formation and control in a simulated spacecraft water system - Three year results

    NASA Technical Reports Server (NTRS)

    Schultz, John R.; Flanagan, David T.; Bruce, Rebekah J.; Mudgett, Paul D.; Carr, Sandra E.; Rutz, Jeffrey A.; Huls, M. H.; Sauer, Richard L.; Pierson, Duane L.

    1992-01-01

    Two simulated spacecraft water systems are being used to evaluate the effectiveness of iodine for controlling microbial contamination within such systems. An iodine concentration of about 2.0 mg/L is maintained in one system by passing ultrapure water through an iodinated ion exchange resin. Stainless steel coupons with electropolished and mechanically-polished sides are being used to monitor biofilm formation. Results after three years of operation show a single episode of significant bacterial growth in the iodinated system when the iodine level dropped to 1.9 mg/L. This growth was apparently controlled by replacing the iodinated ion exchange resin, thereby increasing the iodine level. The second batch of resin has remained effective in controlling microbial growth down to an iodine level of 1.0 mg/L. SEM indicates that the iodine has impeded but may have not completely eliminated the formation of biofilm. Metals analyses reveal some corrosion in the iodinated system after 3 years of continuous exposure. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

  12. ISOLATION AND IDENTIFICATION OF NONTUBERCULOUS MYCOBACTERIA FROM FOODS AS POSSIBLE EXPOSURE SOURCES

    EPA Science Inventory

    A variety of foods collected from local supermarkets and produce stands were examined as possible sources of nontuberculous mycobacterial exposure. Food samples were combined with sterile ultrapure water and manually shaken. To remove large particles, the suspensions were filtere...

  13. Ready-to-eat vegetables production with low-level water chlorination. An evaluation of water quality, and of its impact on end products.

    PubMed

    D'Acunzo, Francesca; Del Cimmuto, Angela; Marinelli, Lucia; Aurigemma, Caterina; De Giusti, Maria

    2012-01-01

    We evaluated the microbiological impact of low-level chlorination (1 ppm free chlorine) on the production of ready-to-eat (RTE) vegetables by monitoring the microbiological quality of irrigation and processing water in two production plants over a 4-season period, as well as the microbiological quality of unprocessed vegetables and RTE product. Water samples were also characterized in terms of some chemical and physico-chemical parameters of relevance in chlorination management. Both producers use water with maximum 1 ppm free chlorine for vegetables rinsing, while the two processes differ by the number of washing cycles. Salmonella spp and Campylobacter spp were detected once in two different irrigation water samples out of nine from one producer. No pathogens were found in the vegetable samples. As expected, the procedure encompassing more washing cycles performed slightly better in terms of total mesophilic count (TMC) when comparing unprocessed and RTE vegetables of the same batch. However, data suggest that low-level chlorination may be insufficient in preventing microbial build-up in the washing equipment and/or batch-to batch cross-contamination.

  14. Detection of genogroup IV norovirus in wastewater and river water in Japan.

    PubMed

    Kitajima, M; Haramoto, E; Phanuwan, C; Katayama, H; Ohgaki, S

    2009-11-01

    To test wastewater and river water in Japan for genogroup IV norovirus (GIV NoV). Influent and effluent samples from a wastewater treatment plant and the Tamagawa River water samples were collected monthly for a year. The water samples were concentrated by the adsorption-elution method, using an HA electronegative filter with acid rinse procedure, followed by quantitative detection of GIV NoV using TaqMan-based real-time RT-PCR. Both wastewater and river water samples showed a high positive ratio of GIV NoV during winter and spring. The highest concentration in wastewater and river water was 6.9 x 10(4) and 1.5 x 10(4) copies l(-1), respectively. Presence of GIV NoV in the environments demonstrates that not only GI and GII NoVs but also GIV strains are circulating and that routine monitoring of GIV NoV in water environments is recommended to understand its epidemics, environmental distribution and potential health risks. This is the first study providing quantitative data on the occurrence of GIV NoV in environmental water over a 1-year period.

  15. Heavy metals (lead, cadmium, methylmercury, arsenic) in commonly imported rice grains (Oryza sativa) sold in Saudi Arabia and their potential health risk.

    PubMed

    Al-Saleh, Iman; Abduljabbar, Mai

    2017-10-01

    The levels of heavy metals (lead, cadmium, methylmercury and arsenic) were determined in 37 brands of imported rice commonly consumed in Saudi Arabia after soaking and rinsing with water, and their potential health risks to residents were estimated by three indices: hazard quotient (HQ), hazard index (HI) and cancer risk (CR). The mean levels of lead, cadmium, methylmercury and total arsenic in soaked (rinsed) rice grains were 0.034 (0.057), 0.015 (0.027), 0.004 (0.007) and 0.202 (0.183) μg/g dry weight, respectively. Soaking or rinsing rice grains with water decreased lead and cadmium levels in all brands to safe levels. All brands had total arsenic above the acceptable regulatory limits, irrespective of soaking or rinsing, and eight soaked and 12 rinsed brands contained methylmercury. The levels of all heavy metals except cadmium were above the acceptable regulatory limits when the rice was neither rinsed nor soaked. Weekly intakes of lead, cadmium, methylmercury and total arsenic from soaked (rinsed) grains were 0.638 (1.068), 0.279 (0.503), 0.271 (0.309) and 3.769 (3.407) μg/kg body weight (bw). The weekly intakes of lead and methylmercury from the consumption of one rinsed and two soaked rice brands respectively, exceeded the Provisional Tolerance Weekly Intake set by the Food and Agriculture Organization and the World Health Organization. The weekly intake of total arsenic for all brands was above the lowest benchmark dose lower confidence limit (BMDL 01 ) level of 0.3μg/kg bw/d for an increased cancer risk set by European Food Safety Authority. Either soaking or rinsing grains before consumption can minimize the non-carcinogenic health risks to residents from cadmium and lead (HQ<1). Our local consumers, though, may experience health consequences from rice contaminated mainly with arsenic (HQ>1 all brands) and to a lesser extent with methylmercury (HQ>1 in 4 brands), even when soaked or rinsed with water before consumption. The combined non

  16. High-volume manufacturing compatible dry development rinse process (DDRP): patterning and defectivity performance for EUVL

    NASA Astrophysics Data System (ADS)

    Sayan, Safak; Vanelderen, Pieter; Hetel, Iulian; Chan, BT; Raghavan, Praveen; Blanco, Victor; Foubert, Philippe; D'urzo, Lucia; De Simone, Danilo; Vandenberghe, Geert

    2017-04-01

    There are many knobs available that change the chemical and physical properties of the photoresists to "break" the RLS (Resolution, Sensitivity, Line edge/width roughness) trade-off, however those are not enough today to realize a material to satisfy all requirements at once for 7nm technology and beyond. DDRP improves the ultimate achievable resolution via pattern collapse mitigation, hence the priority of requirements for the EUV photoresist development may be changed with more focus on Sensitivity and LWR. This may potentially provide a new conceptual approach towards EUV PR development for DDRP applications. We have previously demonstrated pattern collapse (PC) mitigation via DDRP on different EUVL photoresists (including different resist platforms), achieving ultimate resolution and exposure latitude improvements [1,2]. In this contribution, we report patterning and material defect performance of HVM compatible (all aqueous) dry development rinse material. We will also report on process window improvement on 2-dimensional metal structures towards standard cell size reduction with elimination of mask layer(s) using single EUV exposure.

  17. 40 CFR 421.334 - Standards of performance for new sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... range of 7.5 to 10.0 at all times. (d) SiC14 purification wet air pollution control. NSPS for the....600 189.300 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from...) 1 Within the range of 7.5 to 10.0 at all times. (r) Leaching rinse water from zirconium alloy...

  18. 40 CFR 421.334 - Standards of performance for new sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... range of 7.5 to 10.0 at all times. (d) SiC14 purification wet air pollution control. NSPS for the....600 189.300 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from...) 1 Within the range of 7.5 to 10.0 at all times. (r) Leaching rinse water from zirconium alloy...

  19. 40 CFR 421.334 - Standards of performance for new sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... range of 7.5 to 10.0 at all times. (d) SiC14 purification wet air pollution control. NSPS for the....600 189.300 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (q) Leaching rinse water from...) 1 Within the range of 7.5 to 10.0 at all times. (r) Leaching rinse water from zirconium alloy...

  20. Higher Anti-Liver Fibrosis Effect of Cordyceps militaris-Fermented Product Cultured with Deep Ocean Water via Inhibiting Proinflammatory Factors and Fibrosis-Related Factors Expressions.

    PubMed

    Hung, Yu-Ping; Lee, Chun-Lin

    2017-06-08

    Deep ocean water (DOW) has been shown to enhance the functional components of fungi, resulting in increased health benefits. Therefore, using DOW for culturing fungi can enhance the cordycepin and adenosine of Cordyceps militaris (CM) and its protective effects on the liver. In this study, the antiliver fibrosis effects and mechanisms of ultrapure water-cultured CM (UCM), DOW-cultured CM (DCM), synthetic water-cultured CM, DOW, cordycepin, and adenosine were compared in the liver fibrosis mice induced by intraperitoneal injections of thioacetamide (TAA). The results indicated that DCM exhibited superior performance in reducing liver collagen accumulation, mitigating liver injuries, inhibiting proinflammatory factors and fibrosis-related factor (TGF-β1, Smad2/3, α-SMA, COL1A1) expression compared with UCM. DOW, cordycepin, and adenosine also performed antiliver fibrosis effect. Therefore, because DCM is rich in DOW and functional components, it can achieve anti-liver fibrosis effects through multiple pathways. These ameliorative effects are considerably superior to those of UCM.

  1. Demonstration and Validation of a Regenerated-Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground Water Quality and Remediation Progress at DoD Sites

    DTIC Science & Technology

    2007-01-01

    ethanol, sodium benzoate , and ethylene diamine tetra-acetic acid (EDTA). Alternatively, the membrane can be purchased dry, but then must be...cleaned in a series of steps that includes soaking and rinsing in deionized water, heated sodium bicarbonate solution, EDTA, and sodium azide solution to...Potassium Chromium Selenium Sodium Copper Vanadium Aluminum Iron Zinc Arsenic Lead Antimony Manganese Anions (1-3 days) Bicarbonate/Alkalinity

  2. Bacterial repopulation of drinking water pipe walls after chlorination.

    PubMed

    Mathieu, Laurence; Francius, Grégory; El Zein, Racha; Angel, Edith; Block, Jean-Claude

    2016-09-01

    The short-term kinetics of bacterial repopulation were evaluated after chlorination of high-density polyethylene (HDPE) colonized with drinking water biofilms and compared with bare HDPE surfaces. The effect of chlorination was partial as a residual biofilm persisted and was time-limited as repopulation occurred immediately after water resupply. The total number of bacteria reached the same levels on both the bare and chlorinated biofilm-fouled HDPE after a seven-day exposure to drinking water. Due to the presence of a residual biofilm, the hydrophobicity of chlorinated biofilm-fouled surface exhibited much lower adhesion forces (2.1 nN) compared to bare surfaces (8.9 nN). This could explain the rapid repopulation after chlorination, with a twofold faster bacterial accumulation rate on the bare HDPE surface. γ-Proteobacteria dominated the early stages of repopulation of both surfaces and a shift in the dominance occurred over the colonization time. Such observations define a timescale for cleaning frequency in industrial environments and guidelines for a rinsing procedure using drinking water.

  3. Pseudo-outbreak of Cupriavidus pauculus infection at an outpatient clinic related to rinsing culturette swabs in tap water.

    PubMed

    Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti

    2010-07-01

    Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.

  4. Degradation of progestagens by oxidation with potassium permanganate in wastewater effluents.

    PubMed

    Fayad, Paul B; Zamyadi, Arash; Broseus, Romain; Prévost, Michèle; Sauvé, Sébastien

    2013-01-01

    This study investigated the oxidation of selected progestagenic steroid hormones by potassium permanganate at pH 6.0 and 8.0 in ultrapure water and wastewater effluents, using bench-scale assays. Second order rate constants for the reaction of potassium permanganate with progestagens (levonorgestrel, medroxyprogesterone, norethindrone and progesterone) was determined as a function of pH, presence of natural organic matter and temperature. This work also illustrates the advantages of using a novel analytical method, the laser diode thermal desorption (LDTD-APCI) interface coupled to tandem mass spectrometry apparatus, allowing for the quick determination of oxidation rate constants and increasing sample throughput. The second-order rate constants for progestagens with permanganate determined in bench-scale experiments ranged from 23 to 368 M(-1) sec(-1) in both wastewater and ultrapure waters with pH values of 6.0 and 8.0. Two pairs of progestagens exhibited similar reaction rate constants, i.e. progesterone and medroxyprogesterone (23 to 80 M(-1) sec(-1) in ultrapure water and 26 to 149 M(-1) sec(-1) in wastewaters, at pH 6.0 and 8.0) and levonorgestrel and norethindrone (179 to 224 M(-1) sec(-1) in ultrapure water and 180 to 368 M(-1) sec(-1) in wastewaters, at pH 6.0 and 8.0). The presence of dissolved natural organic matter and the pH conditions improved the oxidation rate constants for progestagens with potassium permanganate only at alkaline pH. Reaction rates measured in Milli-Q water could therefore be used to provide conservative estimates for the oxidation rates of the four selected progestagens in wastewaters when exposed to potassium permanganate. The progestagen removal efficiencies was lower for progesterone and medroxyprogesterone (48 to 87 %) than for levonorgestrel and norethindrone (78 to 97%) in Milli-Q and wastewaters at pH 6.0-8.2 using potassium permanganate dosages of 1 to 5 mg L(-1) after contact times of 10 to 60 min. This

  5. Degradation of progestagens by oxidation with potassium permanganate in wastewater effluents

    PubMed Central

    2013-01-01

    Background This study investigated the oxidation of selected progestagenic steroid hormones by potassium permanganate at pH 6.0 and 8.0 in ultrapure water and wastewater effluents, using bench-scale assays. Second order rate constants for the reaction of potassium permanganate with progestagens (levonorgestrel, medroxyprogesterone, norethindrone and progesterone) was determined as a function of pH, presence of natural organic matter and temperature. This work also illustrates the advantages of using a novel analytical method, the laser diode thermal desorption (LDTD-APCI) interface coupled to tandem mass spectrometry apparatus, allowing for the quick determination of oxidation rate constants and increasing sample throughput. Results The second-order rate constants for progestagens with permanganate determined in bench-scale experiments ranged from 23 to 368 M-1 sec-1 in both wastewater and ultrapure waters with pH values of 6.0 and 8.0. Two pairs of progestagens exhibited similar reaction rate constants, i.e. progesterone and medroxyprogesterone (23 to 80 M-1 sec-1 in ultrapure water and 26 to 149 M-1 sec-1 in wastewaters, at pH 6.0 and 8.0) and levonorgestrel and norethindrone (179 to 224 M-1 sec-1 in ultrapure water and 180 to 368 M-1 sec-1 in wastewaters, at pH 6.0 and 8.0). The presence of dissolved natural organic matter and the pH conditions improved the oxidation rate constants for progestagens with potassium permanganate only at alkaline pH. Reaction rates measured in Milli-Q water could therefore be used to provide conservative estimates for the oxidation rates of the four selected progestagens in wastewaters when exposed to potassium permanganate. The progestagen removal efficiencies was lower for progesterone and medroxyprogesterone (48 to 87 %) than for levonorgestrel and norethindrone (78 to 97%) in Milli-Q and wastewaters at pH 6.0-8.2 using potassium permanganate dosages of 1 to 5 mg L-1 after contact times of 10 to 60

  6. Bioactive Surface Modification of Hydroxyapatite

    PubMed Central

    Okazaki, Yohei; Hiasa, Kyou; Yasuda, Keisuke; Nogami, Keisuke; Mizumachi, Wataru; Hirata, Isao

    2013-01-01

    The purpose of this study was to establish an acid-etching procedure for altering the Ca/P ratio of the nanostructured surface of hydroxyapatite (HAP) by using surface chemical and morphological analyses (XPS, XRD, SEM, surface roughness, and wettability) and to evaluate the in vitro response of osteoblast-like cells (MC3T3-E1 cells) to the modified surfaces. This study utilized HAP and HAP treated with 10%, 20%, 30%, 40%, 50%, or 60% phosphoric acid solution for 10 minutes at 25°C, followed by rinsing 3 times with ultrapure water. The 30% phosphoric acid etching process that provided a Ca/P ratio of 1.50, without destruction of the grain boundary of HAP, was selected as a surface-modification procedure. Additionally, HAP treated by the 30% phosphoric acid etching process was stored under dry conditions at 25°C for 12 hours, and the Ca/P ratio approximated to 1.00 accidentally. The initial adhesion, proliferation, and differentiation (alkaline phosphatase (ALP) activity and relative mRNA level for ALP) of MC3T3-E1 cells on the modified surfaces were significantly promoted (P < 0.05 and 0.01). These findings show that the 30% phosphoric acid etching process for the nanostructured HAP surface can alter the Ca/P ratio effectively and may accelerate the initial adhesion, proliferation, and differentiation of MC3T3-E1 cells. PMID:23862150

  7. In vitro activity of an ear rinse containing tromethamine, EDTA, benzyl alcohol and 0.1% ketoconazole on Malassezia organisms from dogs with otitis externa.

    PubMed

    Cole, Lynette K; Luu, Dao H; Rajala-Schultz, Paivi J; Meadows, Cheyney; Torres, Audrey H

    2007-04-01

    The purpose of this study was to evaluate the in vitro activity of an ear rinse containing tromethamine, EDTA, benzyl alcohol and 0.1% ketoconazole in purified water on Malassezia organisms from dogs with otitis externa. Malassezia organisms were collected from ear swab samples from the external ear canal of 19 dogs with otitis externa plus one control strain of Malassezia pachydermatis. Three test solutions were evaluated: ER (EDTA, tromethamine, benzyl alcohol), ER + keto (EDTA, tromethamine, benzyl alcohol, ketoconazole), and H2O (purified water). Ten-millilitre aliquots of each test solution was transferred into 20 tubes and inoculated with one of the isolates (1 tube per isolate: 19 clinical and 1 control strain). Samples were retrieved from each tube at five time points (0, 15, 30, 45 and 60 min), transferred to Petri dishes, mixed with Sabouraud dextrose agar supplemented with 0.5% Tween 80 and incubated. Following incubation, the plates were examined for growth and colonies counted as colony-forming units per millilitre. The data were analysed using a repeated measures analysis, with pair-wise comparisons of solution-time combinations. There was a significant reduction in Malassezia growth in ER + keto at all time points (P < 0.0001) compared to time zero. Neither ER nor H2O had any effect on the growth of Malassezia. ER + keto was significantly more effective in reducing Malassezia growth (P < 0.0001) at all time points compared to both ER and H2O. ER + keto may be useful in the treatment of Malassezia otitis externa. Future studies should be performed to evaluate the in vivo efficacy of ER + keto as treatment for otic infections caused by Malassezia.

  8. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  9. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-09-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  10. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.

    PubMed

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  11. Desorption of radioactive cesium by seawater from the suspended particles in river water.

    PubMed

    Onodera, Masaki; Kirishima, Akira; Nagao, Seiya; Takamiya, Kouichi; Ohtsuki, Tsutomu; Akiyama, Daisuke; Sato, Nobuaki

    2017-10-01

    In 2011, the accident at the Fukushima-Daiichi nuclear power plant dispersed radioactive cesium throughout the environment, contaminating the land, rivers, and sea. Suspended particles containing clay minerals are the transportation medium for radioactive cesium from rivers to the ocean because cesium is strongly adsorbed between the layers of clay minerals, forming inner sphere complexes. In this study, the adsorption and desorption behaviors of radioactive cesium from suspended clay particles in river water have been investigated. The radioactive cesium adsorption and desorption experiments were performed with two kinds of suspended particulate using a batch method with 137 Cs tracers. In the cesium adsorption treatment performed before the desorption experiments, simulated river water having a total cesium concentration ([ 133+137 Cs + ] total ) of 1.3 nM (10 -9  mol/L) was used. The desorption experiments were mainly conducted at a solid-to-liquid ratio of 0.17 g/L. The desorption agents were natural seawater collected at 10 km north of the Fukushima-Daiichi nuclear power plant, artificial seawater, solutions of NaCl, KCl, NH 4 Cl, and 133 CsCl, and ultrapure water. The desorption behavior, which depends on the preloaded cesium concentration in the suspended particles, was also investigated. Based on the cesium desorption experiments using suspended particles, which contained about 1000 ng/g loaded cesium, the order of cesium desorption ratios for each desorption agent was determined as 1 M NaCl (80%) > 470 mM NaCl (65%) > 1 M KCl (30%) ≈ seawater (natural seawater and Daigo artificial seawater) > 1 M NH 4 Cl (20%) > 1 M 133 CsCl (15%) ≫ ultrapure water (2%). Moreover, an interesting result was obtained: The desorption ratio in the 470 mM NaCl solution was much higher than that in seawater, even though the Na + concentrations were identical. These results indicate that the cesium desorption mechanism is not a simple ion exchange reaction

  12. 40 CFR 421.333 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 2.387 1.108 Nickel 4.688 3.154 Ammonia (as N) 1,136.000 499.500 (d) SiCl4 purification wet air....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.000 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  13. 40 CFR 421.333 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 2.387 1.108 Nickel 4.688 3.154 Ammonia (as N) 1,136.000 499.500 (d) SiCl4 purification wet air....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.000 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  14. 40 CFR 421.333 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 2.387 1.108 Nickel 4.688 3.154 Ammonia (as N) 1,136.000 499.500 (d) SiCl4 purification wet air....262 Lead 4.416 2.050 Nickel 8.674 5.835 Ammonia (as N) 2,102.000 895.000 (q) Leaching rinse water from... Nickel 32.410 21.810 Ammonia (as N) 7,856.000 3,453.000 (r) Leaching rinse water from zirconium alloy...

  15. Kinetics, mechanisms, and influencing factors on the treatment of haloacetonitriles (HANs) in water by two household heating devices.

    PubMed

    Shi, Wendong; Wang, Lei; Chen, Baiyang

    2017-04-01

    Haloacetonitriles (HANs) are a group of nitrogenous disinfection by-products (DBPs) commonly found in treated water with potential carcinogenic, cytotoxic, and genotoxic risks. In order to control HANs and understand their real intake levels by people via drinking water, this study evaluated a list of structural, operational, and environmental factors affecting the treatment of HANs by two domestic heating devices, i.e., an electric boiler and a microwave oven. Results show that the concentrations of HANs decreased exponentially over time with increasing temperature, water turbulence, and bubbles, and the phenomena were most likely due to a combined effect of volatilization and hydrolysis. Among HANs, the lability increased with increasing halogenation degrees (i.e., tri- > di- > mono- HANs) yet decreasing halogen molecular weights (i.e., Cl- > Br- > I- HANs); such trends were well captured by quantitative structure activity relationship models (R 2  = 0.99). Operational factors played critical roles in controlling HANs too, including the rate of heating, water volume, water temperature at time of pouring, cooling method, and capping condition, suggesting that people could benefit from proper handling methods and procedures. In addition, HANs added to tap water exhibited higher removals than those added to ultrapure water, probably because of the presence of free chlorine in tap water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. National survey on school-based fluoride mouth-rinsing programme in Japan: regional spread conditions from preschool to junior high school in 2010.

    PubMed

    Komiyama, Karin; Kimoto, Kazunari; Taura, Katsuhiko; Sakai, Osamu

    2014-06-01

    We surveyed the state of implementation of the school-based fluoride mouth-rinsing programme (S-FMR) in schools in Japan from March 2010. Questionnaires on the implementation status of S-FMR in each type of school (including preschool and kindergarten) were sent by post to the oral health administration departments of all 47 prefectures and 89 cities (18 ordinance-designated cities, 23 special wards, 41 core cities and seven public health centres in ordinance-designated cities) with public health centres. The S-FMR implementation rate was low, at only 11% of all schools in Japan and only 6% of all participating school children aged 4-14 years. In many regions, the S-FMR was implemented more widely and received higher participation from children in either elementary schools and junior high schools or preschools and kindergartens. Inter-prefectural disparities were seen in S-FMR implementation, as some prefectures and cities did not include topical fluoride application in their health promotion plans, and some local public bodies did not include targets for fluoride mouth-rinsing. To reduce this disparity in Japan where systemic fluoride application is not performed, each local public body must consider implementing the S-FMR as a public health measure. We propose using the results of this survey as basic data for formulating S-FMR goals (numerical targets) and adopting S-FMR as a concrete measure in the second Healthy Japan 21, to be launched in the fiscal year for 2013, and within the basic matters of the Act Concerning the Promotion of Dental and Oral Health. © 2013 FDI World Dental Federation.

  17. National survey on school-based fluoride mouth-rinsing programme in Japan: regional spread conditions from preschool to junior high school in 2010

    PubMed Central

    Komiyama, Karin; Kimoto, Kazunari; Taura, Katsuhiko; Sakai, Osamu

    2014-01-01

    Aims We surveyed the state of implementation of the school-based fluoride mouth-rinsing programme (S-FMR) in schools in Japan from March 2010. Methods Questionnaires on the implementation status of S-FMR in each type of school (including preschool and kindergarten) were sent by post to the oral health administration departments of all 47 prefectures and 89 cities (18 ordinance-designated cities, 23 special wards, 41 core cities and seven public health centres in ordinance-designated cities) with public health centres. Results The S-FMR implementation rate was low, at only 11% of all schools in Japan and only 6% of all participating school children aged 4–14 years. In many regions, the S-FMR was implemented more widely and received higher participation from children in either elementary schools and junior high schools or preschools and kindergartens. Conclusions Inter-prefectural disparities were seen in S-FMR implementation, as some prefectures and cities did not include topical fluoride application in their health promotion plans, and some local public bodies did not include targets for fluoride mouth-rinsing. To reduce this disparity in Japan where systemic fluoride application is not performed, each local public body must consider implementing the S-FMR as a public health measure. We propose using the results of this survey as basic data for formulating S-FMR goals (numerical targets) and adopting S-FMR as a concrete measure in the second Healthy Japan 21, to be launched in the fiscal year for 2013, and within the basic matters of the Act Concerning the Promotion of Dental and Oral Health. PMID:24256345

  18. In vitro analysis of riboflavin-modified, experimental, two-step etch-and-rinse dentin adhesive: Fourier transform infrared spectroscopy and micro-Raman studies

    PubMed Central

    Daood, Umer; Swee Heng, Chan; Neo Chiew Lian, Jennifer; Fawzy, Amr S

    2015-01-01

    To modify two-step experimental etch-and-rinse dentin adhesive with different concentrations of riboflavin and to study its effect on the bond strength, degree of conversion, along with resin infiltration within the demineralized dentin substrate, an experimental adhesive-system was modified with different concentrations of riboflavin (m/m, 0, 1%, 3%, 5% and 10%). Dentin surfaces were etched with 37% phosphoric acid, bonded with respective adhesives, restored with restorative composite–resin, and sectioned into resin–dentin slabs and beams to be stored for 24 h or 9 months in artificial saliva. Micro-tensile bond testing was performed with scanning electron microscopy to analyse the failure of debonded beams. The degree of conversion was evaluated with Fourier transform infrared spectroscopy (FTIR) at different time points along with micro-Raman spectroscopy analysis. Data was analyzed with one-way and two-way analysis of variance followed by Tukey's for pair-wise comparison. Modification with 1% and 3% riboflavin increased the micro-tensile bond strength compared to the control at 24 h and 9-month storage with no significant differences in degree of conversion (P<0.05). The most predominant failure mode was the mixed fracture among all specimens except 10% riboflavin-modified adhesive specimens where cohesive failure was predominant. Raman analysis revealed that 1% and 3% riboflavin adhesives specimens showed relatively higher resin infiltration. The incorporation of riboflavin in the experimental two-step etch-and-rinse adhesive at 3% (m/m) improved the immediate bond strengths and bond durability after 9-month storage in artificial saliva without adversely affecting the degree of conversion of the adhesive monomers and resin infiltration. PMID:25257880

  19. In vitro analysis of riboflavin-modified, experimental, two-step etch-and-rinse dentin adhesive: Fourier transform infrared spectroscopy and micro-Raman studies.

    PubMed

    Daood, Umer; Swee Heng, Chan; Neo Chiew Lian, Jennifer; Fawzy, Amr S

    2015-06-26

    To modify two-step experimental etch-and-rinse dentin adhesive with different concentrations of riboflavin and to study its effect on the bond strength, degree of conversion, along with resin infiltration within the demineralized dentin substrate, an experimental adhesive-system was modified with different concentrations of riboflavin (m/m, 0, 1%, 3%, 5% and 10%). Dentin surfaces were etched with 37% phosphoric acid, bonded with respective adhesives, restored with restorative composite-resin, and sectioned into resin-dentin slabs and beams to be stored for 24 h or 9 months in artificial saliva. Micro-tensile bond testing was performed with scanning electron microscopy to analyse the failure of debonded beams. The degree of conversion was evaluated with Fourier transform infrared spectroscopy (FTIR) at different time points along with micro-Raman spectroscopy analysis. Data was analyzed with one-way and two-way analysis of variance followed by Tukey's for pair-wise comparison. Modification with 1% and 3% riboflavin increased the micro-tensile bond strength compared to the control at 24 h and 9-month storage with no significant differences in degree of conversion (P<0.05). The most predominant failure mode was the mixed fracture among all specimens except 10% riboflavin-modified adhesive specimens where cohesive failure was predominant. Raman analysis revealed that 1% and 3% riboflavin adhesives specimens showed relatively higher resin infiltration. The incorporation of riboflavin in the experimental two-step etch-and-rinse adhesive at 3% (m/m) improved the immediate bond strengths and bond durability after 9-month storage in artificial saliva without adversely affecting the degree of conversion of the adhesive monomers and resin infiltration.

  20. Economic Evaluation of a School-based Combined Program with a Targeted Pit and Fissure Sealant and Fluoride Mouth Rinse in Japan.

    PubMed

    Sakuma, Shihoko; Yoshihara, Akihiro; Miyazaki, Hideo; Kobayashi, Seigo

    2010-01-01

    In Niigata prefecture, Japan, a system has been developed based on a school-based fluoride mouth rinse program as follows; students with caries susceptible teeth are screened in a school dental examination, and encouraged to receive sealant placement in local dental clinics. However, the cost-effectiveness of sealant application in the public health has been questioned. The aim of this study was to estimate of the cost-effectiveness and cost-benefit ratio for a school-based combined program with fluoride mouth rinse and targeted fissure sealant in children residing in non-fluoridated areas in Japan. The analysis was based on comparing an intervention group with two cohorts in the 8-year-old (n=66) and 11-year-old (n=58) participating in the combined program for four and seven years, respectively, with a control group of the same grades (n=43 and n=54 respectively). The study measured mean differences in number of decayed and filled teeth (DFT) between the study groups and a combined program cost per child during study periods. The cost-effectiveness ratio was expressed as an individual annual program cost per DFT averted. In the cost-benefit ratio the mean difference in treatment cost between groups (program benefit) was compared to program cost. The mean reduced DFT differences between groups were 1.44 in 8-year-old and 3.17 in 11-year-old children. The cost-effectiveness ratio was ¥ 493 in the 8-year-old and ¥ 202 in the 11-year-old, respectively. The cost-benefit ratio was 1.84 in 8-year-old children and 2.42 in 11-year-old. This combined program indicated acceptable cost-effectiveness and cost -benefit ratio.

  1. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    PubMed

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  2. Improvement of exposure times: effects on adhesive properties and resin-dentin bond strengths of etch-and-rinse adhesives.

    PubMed

    Ferreira, Sabrina Queji; Costa, Thays Regina; Klein-Júnior, Celso Afonso; Accorinte, Maria de; Meier, Márcia Margarete; Loguercio, Alessandro Dourado; Reis, Alessandra

    2011-06-01

    This study evaluated the effect of prolonged polymerization times on the microtensile resin-dentin bond strength (μTBS), degree of conversion of adhesive films (DC) and silver nitrate uptake (SNU) for an ethanol/water- (Adper Single Bond 2, [SB]) and an acetone-based (One Step Plus, [OS]) etch-and-rinse adhesive. Thirty caries-free extracted molars were included in this study. The occlusal enamel of all teeth was removed by wet grinding the occlusal enamel on 180-grit SiC paper. Adhesives were applied according to the manufacturer's instructions, but they were light cured for 10, 20 and 40 s at 600 mW/cm2. Bonded sticks (0.6 mm2) were tested in tension (0.5 mm/min). Two bonded sticks from each tooth were immersed in an ammoniacal solution of silver nitrate (24 h), photodeveloped (8 h), and analyzed by SEM. The DC of the adhesives was evaluated under Fourier Transformed Infra-Red spectroscopy (FTIR). Data for each property were analyzed by two-way ANOVA and Tukey's test (α = 0.05). Statistically higher μTBS and DC were observed for SB and OS when both adhesives were light cured for 40 s in comparison with 10 s. For OS, the μTBS in the 20- and 40-s groups did not differ statistically, while for SB it did. Higher prolonged exposure times did not prevent nanoleakage within the hybrid layer for all groups regardless of the adhesive. This study supports the hypothesis that exposure times longer than those recommended can improve the degree of conversion of adhesive films and the immediate resin-dentin bonds. The prolonged curing times (20 and 40 s) for polymerization of simplified adhesives resulted in an increase in the degree of conversion of the adhesive films and resin-dentin bond strengths but did not reduce the nanoleakage within the hybrid layer.

  3. Water characteristics associated with the occurrence of Legionella pneumophila in dental units.

    PubMed

    Zanetti, F; Stampi, S; De Luca, G; Fateh-Moghadam, P; Antonietta, M; Sabattini, B; Checchi, L

    2000-02-01

    This study evaluated the incidence of Legionella pneumophila in dental unit water samples and investigated how the occurrence of these bacteria may be related to some physical, chemical and bacteriological characteristics of the water. The samples were taken from the incoming tap water, oral rinsing cup, air-water syringe, ultrasonic scaler, and the turbine of 23 dental units of private and public institutions. Apart from L. pneumophila (serogroup 1 and 3) isolated in 22 out of the 101 (21.8%) water samples tested, two other species were found: L. bozemanii and L. dumoffii. The highest densities and frequency of L. pneumophila were observed in the water coming into the units and in the dental units of public institutions. A negative association between L. pneumophila and 36 degrees C and 22 degrees C heterotrophic total plate counts and other gram-negative bacteria was found. An inverse association between the concentration of L. pneumophila and water temperature was also observed. The values of pH and total hardness did not show any significant difference in the L. pneumophila-positive and -negative dental unit waters. Finally, the chemical oxygen demand (COD) and residual chlorine were found to correlate positively with L. pneumophila.

  4. Fullerene Transport in Saturated Porous Media

    EPA Science Inventory

    We investigated the effects of background solution chemistry and residence time within the soil column on the transport of aqu/C60 through saturated ultrapure quartz sand columns. Aqu/C60 breakthrough curves were obtained under different pore water velocities, solution pHs, and i...

  5. Microbiological evaluation of octenidine dihydrochloride mouth rinse after 5 days' use in orthodontic patients.

    PubMed

    Dogan, Alev Aksoy; Cetin, Emel Sesli; Hüssein, Emad; Adiloglu, Ali Kudret

    2009-07-01

    To determine the absolute and relative antibacterial activity of octenidine dihydrochloride (OCT) against total and cariogenic bacteria in saliva samples of patients with fixed orthodontic appliances during 5 days of usage. The study group consisted of 5 male and 13 female subjects who were selected from patients in the Clinic of Orthodontics. Each patient was given physiologic saline (PS), chlorhexidine gluconate (CHX), polyvinylpyrrolidone-iodine complex (PVP-I), and OCT every morning for 5 days, each separated by a 2-week interval. Total and cariogenic bacteria in saliva samples of orthodontically treated patients with fixed appliances were collected during 5 days of usage. Unstimulated saliva was collected as a baseline sample. Saliva samples were collected at 15 minutes, and on the second, third, and fifth day after rinsing the mouth with any of the solutions for 30 seconds, and bacterial counts were detected. OCT showed an ultimate reduction of total viable oral bacteria, Lactobacillus species, and Streptococcus mutans in vivo. OCT also had a significantly greater inhibitory effect than 0.2% CHX and 7.5% PVP-I, from the beginning of the study until the fifth day after the orthodontic appliances were bonded (P < .1). OCT compared favorably with respect to CHX and PVP-I complex in orthodontically treated patients with fixed appliances (P

  6. Molecular identification of polymers and anthropogenic particles extracted from oceanic water and fish stomach - A Raman micro-spectroscopy study.

    PubMed

    Ghosal, Sutapa; Chen, Michael; Wagner, Jeff; Wang, Zhong-Min; Wall, Stephen

    2018-02-01

    Pacific Ocean trawl samples, stomach contents of laboratory-raised fish as well as fish from the subtropical gyres were analyzed by Raman micro-spectroscopy (RMS) to identify polymer residues and any detectable persistent organic pollutants (POP). The goal was to access specific molecular information at the individual particle level in order to identify polymer debris in the natural environment. The identification process was aided by a laboratory generated automated fluorescence removal algorithm. Pacific Ocean trawl samples of plastic debris associated with fish collection sites were analyzed to determine the types of polymers commonly present. Subsequently, stomach contents of fish from these locations were analyzed for ingested polymer debris. Extraction of polymer debris from fish stomach using KOH versus ultrapure water were evaluated to determine the optimal method of extraction. Pulsed ultrasonic extraction in ultrapure water was determined to be the method of choice for extraction with minimal chemical intrusion. The Pacific Ocean trawl samples yielded primarily polyethylene (PE) and polypropylene (PP) particles >1 mm, PE being the most prevalent type. Additional microplastic residues (1 mm - 10 μm) extracted by filtration, included a polystyrene (PS) particle in addition to PE and PP. Flame retardant, deca-BDE was tentatively identified on some of the PP trawl particles. Polymer residues were also extracted from the stomachs of Atlantic and Pacific Ocean fish. Two types of polymer related debris were identified in the Atlantic Ocean fish: (1) polymer fragments and (2) fragments with combined polymer and fatty acid signatures. In terms of polymer fragments, only PE and PP were detected in the fish stomachs from both locations. A variety of particles were extracted from oceanic fish as potential plastic pieces based on optical examination. However, subsequent RMS examination identified them as various non-plastic fragments, highlighting the importance

  7. [Influence of mineral water on absorption of oral alendronate in rats].

    PubMed

    Akagi, Yuuki; Sakaue, Tomoyuki; Yoneyama, Eiji; Aoyama, Takao

    2011-01-01

    Alendronate, an oral bisphosphonate (e.g., Fosamax(®)), is effective in the treatment of osteoporosis, and the Fosamax(®) package insert advises that the bioavailability is reduced when taken with mineral water containing high levels of metal cations (Ca(2+), Mg(2+), etc.). However, standards regarding the water used when taking alendronate are unclear. In this study, the influence of mineral water on the absorption of oral alendronate was investigated based on urinary excretion of its unchanged form in rats. Alendronate was diluted in each water sample and administered orally (0.7 mg/kg) to male Wistar rats after 24-hour fast. Urine samples were collected until 24 h after dosing. Urine samples were alkalinized, and alendronate in urine was precipitated as a calcium salt, followed by loading on an anion exchange cartridge. Eluted alendronate was derivatized with 9-fluorenylmethoxycarbonyl (Fmoc) chloride and determined by HPLC with fluorescent detection. Cumulative urinary excretion recoveries of alendronate were calculated from the amounts of urinary excretion. Alendronate was rapidly excreted in the first 6 h, and similar elimination rate constants were seen (from 0.28 to 0.45 h(-1/2)) among the water samples. Cumulative urinary excretion recoveries with tap water, evian(®) and 100% deep ocean water were 0.98±0.17%, 0.80±0.18% and 1.01±0.16% (mean±S.E., n=4). Those with Contrex(®) (0.33±0.07%) were significantly lower when compared with ultrapure water (1.56±0.35%, p<0.01). These findings suggest that the absorption of alendronate decreases based on the calcium concentration of mineral water. In conclusion, mineral water containing high levels of calcium is not recommended when alendronate is taken.

  8. Metals of Deep Ocean Water Increase the Anti-Adipogenesis Effect of Monascus-Fermented Product via Modulating the Monascin and Ankaflavin Production.

    PubMed

    Lung, Tzu-Ying; Liao, Li-Ya; Wang, Jyh-Jye; Wei, Bai-Luh; Huang, Ping-Yi; Lee, Chun-Lin

    2016-05-27

    Deep ocean water (DOW) obtained from a depth of more than 200 m includes abundant nutrients and minerals. DOW was proven to positively increase monascin (MS) and ankaflavin (AK) production and the anti-adipogenesis effect of Monascus-fermented red mold dioscorea (RMD). However, the influences that the major metals in DOW have on Monascus secondary metabolite biosynthesis and anti-adipogenesis remain unknown. Therefore, the major metals in DOW were used as the culture water to produce RMD. The secondary metabolites production and anti-adipogenesis effect of RMD cultured with various individual metal waters were investigated. In the results, the addition of water with Mg, Ca, Zn, and Fe increased MS and AK production and inhibited mycotoxin citrinin (CT). However, the positive influence may be contributed to the regulation of pigment biosynthesis. Furthermore, in the results of cell testing, higher lipogenesis inhibition was seen in the treatments of various ethanol extracts of RMD cultured with water containing Mg, K, Zn, and Fe than in those of RMD cultured with ultra-pure water. In conclusion, various individual metals resulted in different effects on MS and AK productions as well as the anti-adipogenesis effect of RMD, but the specific metals contained in DOW may cause synergistic or comprehensive effects that increase the significantly positive influence.

  9. Metals of Deep Ocean Water Increase the Anti-Adipogenesis Effect of Monascus-Fermented Product via Modulating the Monascin and Ankaflavin Production

    PubMed Central

    Lung, Tzu-Ying; Liao, Li-Ya; Wang, Jyh-Jye; Wei, Bai-Luh; Huang, Ping-Yi; Lee, Chun-Lin

    2016-01-01

    Deep ocean water (DOW) obtained from a depth of more than 200 m includes abundant nutrients and minerals. DOW was proven to positively increase monascin (MS) and ankaflavin (AK) production and the anti-adipogenesis effect of Monascus-fermented red mold dioscorea (RMD). However, the influences that the major metals in DOW have on Monascus secondary metabolite biosynthesis and anti-adipogenesis remain unknown. Therefore, the major metals in DOW were used as the culture water to produce RMD. The secondary metabolites production and anti-adipogenesis effect of RMD cultured with various individual metal waters were investigated. In the results, the addition of water with Mg, Ca, Zn, and Fe increased MS and AK production and inhibited mycotoxin citrinin (CT). However, the positive influence may be contributed to the regulation of pigment biosynthesis. Furthermore, in the results of cell testing, higher lipogenesis inhibition was seen in the treatments of various ethanol extracts of RMD cultured with water containing Mg, K, Zn, and Fe than in those of RMD cultured with ultra-pure water. In conclusion, various individual metals resulted in different effects on MS and AK productions as well as the anti-adipogenesis effect of RMD, but the specific metals contained in DOW may cause synergistic or comprehensive effects that increase the significantly positive influence. PMID:27240384

  10. Central online hemodiafiltration in Japan: management of water quality and practice.

    PubMed

    Yamashita, Akihiro C; Sato, Takashi

    2009-01-01

    Hemodiafiltration (HDF) includes a variety of technologies and preparation of ultrapure dialysis fluid has made it possible to perform online HDF and its extensive alternatives. According to current statistics, 5.8% of ESRD patients are treated with HDF in Japan. The majority of these HDF treatments are performed using the central dialysis fluid delivery system (CDDS), this is because most Japanese clinicians and researchers consider that with CDDS it is easier to prepare substitution fluid; moreover, CDDS has economical advantages against single-patient dialysis machine (SPDM)-based counterparts. The water quality at each patient station (dialysis console) is regularly validated by bacterial culture (colony-forming units) and by measuring endotoxin concentration (ET). Since ET measurement takes much less time than bacterial culture, ET is often used as an indicator to verify the water quality for online use. Dialysis fluid with ET below the detection level (usually <0.001 EU/ml) is used for online substitution. In CDDS online HDF, since dialysis clinics must prepare not only the dialysis fluid but also the substitution fluid, they need to satisfy almost the same requirements as pharmaceutical water treatment factories do. The Japanese Society for Dialysis Therapy (JSDT) together with the Japanese Society for Hemodiafiltration (JS-HDF) is now preparing guidelines to meet all these necessary requirements on a worldwide basis. (c) 2009 S. Karger AG, Basel.

  11. Comparison of the antibacterial efficacy and acceptability of an alcohol-based hand rinse with two alcohol-based hand gels during routine patient care.

    PubMed

    Barbut, Frédéric; Maury, Eric; Goldwirt, Laurianne; Boëlle, Piérre-Yves; Neyme, Denis; Aman, Rubina; Rossi, Beatrice; Offenstadt, Georges

    2007-06-01

    The aims of this study were to compare the antibacterial efficacy of handrubbing with an alcoholic rinse (AHRR) and two different alcoholic gels (AHRG) in reducing hand contamination under practical use conditions. We wanted to assess the acceptability of the three products and to determine the effect of each product on overall hand hygiene compliance. A prospective alternating time-series clinical trial was performed in a medical intensive care unit. The study was divided into three six-week periods (P1, P2, P3). Handrubbing was achieved with Sterillium rinse (AHRR) during P1, sterillium gel(AHRG-1) during P2 and Manugel Plus (AHRG-2) during P3. Pre- and post-rubbing hand contaminations were assessed immediately after a direct contact with a patient, using the glove juice technique. Health care workers (HCWs) evaluated the acceptability of the products through a self-administered anonymous questionnaire. Compliance of HCWs with hand hygiene was assessed during the three periods. We studied 242 handrubbing opportunities. The mean reduction factor (expressed as the Log(10) CFU/mL) of the AHRR, AHRG-1 and AHRG-2 were 1.28+/-0.95, 1.29+/-0.84 and 0.51+/-0.73, respectively (p<0.001). Assessment of the three products by HCWs indicated that AHRR and AHRG-1 were significantly better accepted than AHRG-2. The overall compliance of HCWs to hand hygiene was better when gel was available. Under practical use conditions, AHRG-1 and AHRR were more effective than AHRG-2, although all were claimed to pass the European standard EN1500. In vivo trials are essential to compare the antimicrobial efficacy of products for handrubbing.

  12. Evaluation of HPV-16 and HPV-18 specific antibody measurements in saliva collected in oral rinses and merocel® sponges.

    PubMed

    Parker, Katherine H; Kemp, Troy J; Pan, Yuanji; Yang, Zhen; Giuliano, Anna R; Pinto, Ligia A

    2018-05-03

    Current Human papillomavirus (HPV) L1 VLP vaccines protect against HPV-16 and HPV-18-associated cancers, in females and males. Although correlates of protection have not been identified, HPV-specific antibodies at sites of infection are thought to be the main mechanism of protection afforded by vaccination. Oral sampling has gained increased attention as a potential alternative to serum in monitoring immunity to vaccination and understanding local immunity in oral cancers. Serum was collected via venipuncture, and saliva was collected via oral rinses and Merocel® sponges from healthy volunteers: 16 unvaccinated females, 6 females (ages 24-41) and 6 mid-adult aged males (ages 27-45) recipients of three doses of the HPV-16/18/6/11 vaccine (Gardasil®). Mid-adult male vaccine trial participants were compared to female participants. Samples were tested for anti-HPV-16 and anti-HPV-18 immunoglobulin G levels by an L1 virus-like particle-based enzyme-linked immunosorbent assay (ELISA). All vaccinated participants had detectable serum anti-HPV-16 and anti-HPV-18 antibodies. Optimal standard concentration range and sample serial dilutions for oral rinses were determined. The standard curve was not affected by the type of solution examined. Reproducibility of HPV-16 and HPV-18 antibody titers in mouthwash (overall CV < 10%) or in Merocel® extraction buffer was robust (CV < 13%). Excellent assay linearity (R 2  > 0.9) was observed for sera spiked controls in both solutions. HPV-16 and HPV-18 specific antibodies were detectable in saliva from vaccine recipients, both in mouthwash and in Merocel® sponges but levels were several logs lower than those in serum. This study confirms the application of HPV-16 and HPV-18 ELISAs currently used in sero-epidemiological studies of immunogenicity of HPV vaccines for use with oral samples. Oral samples may be a useful resource for the detection of HPV-16 and HPV-18-specific antibodies in saliva following vaccination

  13. Enhanced electron transfer and silver-releasing suppression in Ag-AgBr/titanium-doped Al2O3 suspensions with visible-light irradiation.

    PubMed

    Zhou, Xuefeng; Hu, Chun; Hu, Xuexiang; Peng, Tianwei

    2012-06-15

    Ag-AgBr was deposited onto mesoporous alumina (MA) and titanium-doped MA by a deposition-precipitation method. The photocatalytic activity and the dissolution of Ag(+) from different catalysts were investigated during the photodegradation of 2-chlorophenol (2-CP) and phenol in ultrapure water and tap water with visible-light irradiation. With the increase in doped titanium, the Ag(+) dissolution decreased with a decrease in the photocatalytic activity. Ag-AgBr/MA-Ti1 was considered the better catalyst for practical applications because its Ag(+) dissolution was minimal (0.4 mg L(-1) in ultrapure water and 5 μg L(-1) in tap water), although its photoactivity was slightly less than that of Ag-AgBr/MA. The dissolution of Ag(+) was related to a charge-transfer process based on the study of cyclic voltammetry analyses under a variety of experimental conditions. The results suggested that several types of anions in the water, including CO(3)(2-), SO(4)(2-), and Cl(-), could act as electron donors that trap the photogenerated holes on Ag nanoparticles to facilitate electron circulation; this would decrease the release of Ag(+). Our studies indicated that the catalyst had a higher activity and stability in water purification. Copyright © 2012. Published by Elsevier B.V.

  14. Effects of shampoo and water washing on hair cortisol concentrations.

    PubMed

    Hamel, Amanda F; Meyer, Jerrold S; Henchey, Elizabeth; Dettmer, Amanda M; Suomi, Stephen J; Novak, Melinda A

    2011-01-30

    Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Effects of Shampoo and Water Washing on Hair Cortisol Concentrations

    PubMed Central

    Hamel, Amanda F.; Meyer, Jerrold S.; Henchey, Elizabeth; Dettmer, Amanda M.; Suomi, Stephen J.; Novak, Melinda A.

    2010-01-01

    Background Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Methods Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Results Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Conclusions Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. PMID:21034727

  16. Microbiological Evaluation of the Efficacy of Soapy Water to Clean Hands: A Randomized, Non-Inferiority Field Trial

    PubMed Central

    Amin, Nuhu; Pickering, Amy J.; Ram, Pavani K.; Unicomb, Leanne; Najnin, Nusrat; Homaira, Nusrat; Ashraf, Sania; Abedin, Jaynal; Islam, M. Sirajul; Luby, Stephen P.

    2014-01-01

    We conducted a randomized, non-inferiority field trial in urban Dhaka, Bangladesh among mothers to compare microbial efficacy of soapy water (30 g powdered detergent in 1.5 L water) with bar soap and water alone. Fieldworkers collected hand rinse samples before and after the following washing regimens: scrubbing with soapy water for 15 and 30 seconds; scrubbing with bar soap for 15 and 30 seconds; and scrubbing with water alone for 15 seconds. Soapy water and bar soap removed thermotolerant coliforms similarly after washing for 15 seconds (mean log10 reduction = 0.7 colony-forming units [CFU], P < 0.001 for soapy water; mean log10 reduction = 0.6 CFU, P = 0.001 for bar soap). Increasing scrubbing time to 30 seconds did not improve removal (P > 0.05). Scrubbing hands with water alone also reduced thermotolerant coliforms (mean log10 reduction = 0.3 CFU, P = 0.046) but was less efficacious than scrubbing hands with soapy water. Soapy water is an inexpensive and microbiologically effective cleansing agent to improve handwashing among households with vulnerable children. PMID:24914003

  17. Orthodontic instrument sterilization with microwave irradiation.

    PubMed

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-04-01

    This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups - Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min.

  18. Comparison of in vitro and in vivo bioassays to measure thyroid hormone disrupting activity in water extracts.

    PubMed

    Leusch, Frederic D L; Aneck-Hahn, Natalie H; Cavanagh, Jo-Anne E; Du Pasquier, David; Hamers, Timo; Hebert, Armelle; Neale, Peta A; Scheurer, Marco; Simmons, Steven O; Schriks, Merijn

    2018-01-01

    Environmental chemicals can induce thyroid disruption through a number of mechanisms including altered thyroid hormone biosynthesis and transport, as well as activation and inhibition of the thyroid receptor. In the current study six in vitro bioassays indicative of different mechanisms of thyroid disruption and one whole animal in vivo assay were applied to 9 model compounds and 4 different water samples (treated wastewater, surface water, drinking water and ultra-pure lab water; both unspiked and spiked with model compounds) to determine their ability to detect thyroid active compounds. Most assays correctly identified and quantified the model compounds as agonists or antagonists, with the reporter gene assays being the most sensitive. However, the reporter gene assays did not detect significant thyroid activity in any of the water samples, suggesting that activation or inhibition of the thyroid hormone receptor is not a relevant mode of action for thyroid endocrine disruptors in water. The thyroperoxidase (TPO) inhibition assay and transthyretin (TTR) displacement assay (FITC) detected activity in the surface water and treated wastewater samples, but more work is required to assess if this activity is a true measure of thyroid activity or matrix interference. The whole animal Xenopus Embryonic Thyroid Assay (XETA) detected some activity in the unspiked surface water and treated wastewater extracts, but not in unspiked drinking water, and appears to be a suitable assay to detect thyroid activity in environmental waters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Mechanical and microbiological properties and drug release modeling of an etch-and-rinse adhesive containing copper nanoparticles.

    PubMed

    Gutiérrez, M F; Malaquias, P; Matos, T P; Szesz, A; Souza, S; Bermudez, J; Reis, A; Loguercio, A D; Farago, P V

    2017-03-01

    To evaluate the effect of addition of copper nanoparticles (CN) at different concentrations into a two-step etch-and-rinse (2-ER) adhesive on antimicrobial activity (AMA), copper release (CR), ultimate tensile strength (UTS), degree of conversion (DC), water sorption (WS), solubility (SO), as well as the immediate (IM) and 1-year resin-dentin bond strength (μTBS) and nanoleakage (NL). Seven adhesives were formulated according to the addition of CN (0, 0.0075, 0.015, 0.06, 0.1, 0.5 and 1wt%) in adhesive. The AMA was evaluated against Streptococcus mutans using agar diffusion assay. For CR, WS and SO, specimens were constructed and tested for 28 days. For UTS, specimens were tested after 24h and 28 days. For DC, specimens were constructed and tested after 24h by FTIR. After enamel removal, the ER was applied to dentin. After composite resin build-ups, specimens were sectioned to obtain resin-dentin sticks. For μTBS and NL, specimens were tested after 24h and 1-year periods. All data were submitted to statistical analysis (α=0.05). The addition of CN provided AMA to the adhesives at all concentrations. Higher CR was observed in adhesives with higher concentration of CN. UTS, DC, WS and SO were not influenced. For μTBS an increase was observed in 0.1 and 0.5% copper group. For NL, a significant decrease was observed in all groups in comparison with control group. After 1-year, no significant reductions of μTBS and no significant increases of NL were observed for copper containing adhesives compared to the control group. The addition of CN in concentrations up to 1wt% in the 2-ER adhesive may be an alternative to provide AMA and preserve the bonding to dentin, without reducing adhesives' mechanical properties evaluated. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. Simultaneous determination of cyanogen chloride and cyanogen bromide in treated water at sub-microg/L levels by a new solid-phase microextraction-gas chromatographic-electron-capture detection method.

    PubMed

    Cancho, B; Ventur, F; Galceran, M

    2000-11-03

    A headspace solid-phase microextraction (HS-SPME) procedure has been developed and applied for the determination of cyanogen halides in treated water samples at microg/L concentrations. Several SPME coatings were tested, the divinylbenzene-Carboxen-polydimethylsiloxane fiber being the most appropriate coating. GC-electron-capture detection was used for separation and quantitation. Experimental parameters such as sample volume, addition of a salt, extraction time and desorption conditions were studied. The optimized method has an acceptable linearity, good precision, with RSD values <10% for both compounds, and it is sufficiently sensitive to detect ng/L levels. HS-SPME was compared with liquid-liquid microextraction (US Environmental Protection Agency Method 551.1) for the analysis of spiked ultrapure and granular activated carbon filtered water samples. There was good agreement between the results from both methods. Finally, the optimized procedure was applied to determine both compounds at the Barcelona water treatment plant (N.E. Spain). Cyanogen chloride in treated water was <1.0 microg/L and cyanogen bromide ranged from 3.2 to 6.4 microg/L.

  1. Water management practices in rural and urban homes: a case study from Bangladesh on ingestion of polluted water.

    PubMed

    Ahmed, S A; Hoque, B A; Mahmud, A

    1998-09-01

    Although Bangladesh has achieved remarkable success in extending the availability of hand pumped and piped water, unsafe water is still ingested. This brief study attempted to assess water management practices in rural and urban homes in Bangladesh so as to establish the routes by which unsafe water is ingested, to examine methods of collection and storage, and determine why unsafe water sources are used when unsafe supplies are available. Forty-eight rural and forty-five urban slum households were studied. Observations, interviews and water quality investigations were conducted. The results show that the respondents were aware that hand pump/tap water is safe and took care to use these safe sources for drinking purposes. However, they continued to use surface water for non-drinking activities such as bathing, washing and rinsing their mouths. Reasons were given that it was a traditional practice to bathe in surface water and was more enjoyable. One of the reasons given for not using hand pumped water to wash clothing and food was that such groundwater caused staining. Bacteriological results from such ingested water showed the quality, especially in rural areas, to be poor. Results also showed the internal surfaces of the base of storage containers to be heavily contaminated with bacteria. This showed that water that was safe when it was first drawn would became contaminated during storage. This study had a limited scope; much further research is needed to find what determines and how water becomes contaminated in containers. These factors include how to reduce contamination of water, in particular the relationship between growth of bacteria in stored water and the material from which the container is made and how to improve the overall quality of water. On the management side, studies could be conducted as to how to improve people's understanding of the use of water for domestic purposes and its safe management.

  2. Influence of Application Time and Etching Mode of Universal Adhesives on Enamel Adhesion.

    PubMed

    Sai, Keiichi; Takamizawa, Toshiki; Imai, Arisa; Tsujimoto, Akimasa; Ishii, Ryo; Barkmeier, Wayne W; Latta, Mark A; Miyazaki, Masashi

    2018-01-01

    To investigate the influence of application time and etching mode of universal adhesives on enamel adhesion. Five universal adhesives, Adhese Universal, Bondmer Lightless, Clearfil Universal Bond Quick, G-Premio Bond, and Scotchbond Universal, were used. Bovine incisors were prepared and divided into four groups of ten teeth each. SBS, Ra, and SFE were determined after the following procedures: 1. self-etch mode with immediate air blowing after application (IA); 2. self-etch mode with prolonged application time (PA); 3. etch-and-rinse mode with IA; 4. etch-and-rinse mode with PA. After 24-h water storage, the bonded assemblies were subjected to shear bond strength (SBS) tests. For surface roughness (Ra) and surface free energy (SFE) measurements, the adhesives were simply applied to the enamel and rinsed with acetone and water before the measurements were carried out. Significantly higher SBS and Ra values were obtained with etch-and-rinse mode than with self-etch mode regardless of the application time or type of adhesive. Although most adhesives showed decreased SFE values with increased application time in self-etch mode, SFE values in etch-and-rinse mode were dependent on the adhesive type and application time. Etching mode, application time, and type of adhesive significantly influenced the SBS, Ra, and SFE values.

  3. The use of an oxidising mouthwash to reduce staining associated with chlorhexidine. Studies in vitro and in vivo.

    PubMed

    Addy, M; al-Arrayed, F; Moran, J

    1991-04-01

    Discolouration of the teeth, tongue and dental restorative materials associated with the use of cationic antiseptics is still the limiting factor in long-term usage of antiplaque agents such as chlorhexidine. Oxidising agents have been used successfully to remove dental stain in animals, but products and regimens have not been evaluated in humans. These pilot studies in vitro and in vivo assessed a long-established oxidising mouthwash, based on peroxyborate, for stain removal from teeth and acrylic. The laboratory studies measured chlorhexidine tea stain removal from tooth and acrylic specimens. The oxidising agent markedly reduced staining on specimens. In a short-term clinical experiment, dental staining was forced over a 2 1/2-day period by reciprocal chlorhexidine and tea rinsing. 5 rinses with the oxidising mouthwash during the next 1 1/2 days dramatically reduced staining compared with water after rinses. Additionally, a single rinse with peroxyborate following the 5 water after rinses, again considerably reduced the residual staining. Effects on tongue staining were less impressive. Both experimental models produced findings consistent with those from the animal model. The results suggest proprietary oxidising mouthwashes could have a place in the control of dental stain associated with the use of chlorhexidine. Further studies to evaluate such products in a more conventional chlorhexidine regimen are indicated.

  4. Biological iron oxidation by Gallionella spp. in drinking water production under fully aerated conditions.

    PubMed

    de Vet, W W J M; Dinkla, I J T; Rietveld, L C; van Loosdrecht, M C M

    2011-11-01

    Iron oxidation under neutral conditions (pH 6.5-8) may be a homo- or heterogeneous chemically- or a biologically-mediated process. The chemical oxidation is supposed to outpace the biological process under slightly alkaline conditions (pH 7-8). The iron oxidation kinetics and growth of Gallionella spp. - obligatory chemolithotrophic iron oxidizers - were assessed in natural, organic carbon-containing water, in continuous lab-scale reactors and full-scale groundwater trickling filters in the Netherlands. From Gallionella cell numbers determined by qPCR, balances were made for all systems. The homogeneous chemical iron oxidation occurred in accordance with the literature, but was retarded by a low water temperature (13 °C). The contribution of the heterogeneous chemical oxidation was, despite the presence of freshly formed iron oxyhydroxides, much lower than in previous studies in ultrapure water. This could be caused by the adsorption of natural organic matter (NOM) on the iron oxide surfaces. In the oxygen-saturated natural water with a pH ranging from 6.5 to 7.7, Gallionella spp. grew uninhibited and biological iron oxidation was an important, and probably the dominant, process. Gallionella growth was not even inhibited in a full-scale filter after plate aeration. From this we conclude that Gallionella spp. can grow under neutral pH and fully aerated conditions when the chemical iron oxidation is retarded by low water temperature and inhibition of the autocatalytic iron oxidation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; use of a modified ultrasonic nebulizer for the analysis of low ionic-strength water by inductively coupled optical emission spectrometry

    USGS Publications Warehouse

    Harris, Carl M.; Litteral, Charles J.; Damrau, Donna L.

    1997-01-01

    The U.S. Geological Survey National Water Quality Laboratory has developed a method for the determination of dissolved calcium, iron, magnesium, manganese, silica, and sodium using a modified ultrasonic nebulizer sample-introduction system to an inductively coupled plasma-optical emission spectrometer. The nebulizer's spray chamber has been modified to avoid carryover and memory effects common in some conventional ultrasonic designs. The modified ultrasonic nebulizer is equipped with a high-speed rinse cycle to remove previously analyzed samples from the spray chamber without excessive flush times. This new rinse cycle decreases sample washout times by reducing carryover and memory effects from salt or analytes in previously analyzed samples by as much as 45 percent. Plasma instability has been reduced by repositioning the argon carrier gas inlet on the spray chamber and by directly pumping waste from the chamber, instead of from open drain traps, thereby maintaining constant pressure to the plasma. The ultrasonic nebulizer improves signal intensities, which are 8 to 16 times greater than for a conventional cross-flow pneumatic nebulizer, without being sensitive to clogging from salt buildup as in cross-flow nebulizers. Detection limits for the ultrasonic nebulizer are 4 to 18 times less than detection limits achievable using a cross-flow pneumatic nebulizer, with equivalent sample analysis time.

  6. Toxicity of ZnO nanoparticles to Escherichia coli: mechanism and the influence of medium components.

    PubMed

    Li, Mei; Zhu, Lizhong; Lin, Daohui

    2011-03-01

    Water chemistry can be a major factor regulating the toxicity mechanism of ZnO nanoparticles (nano-ZnO) in water. The effect of five commonly used aqueous media with various chemical properties on the toxicity of nano-ZnO to Escherichia coli O111 (E. coli) was investigated, including ultrapure water, 0.85% NaCl, phosphate-buffered saline (PBS), minimal Davis (MD), and Luria-Bertani (LB). Combined results of physicochemical characterization and antibacterial tests of nano-ZnO in the five media suggest that the toxicity of nano-ZnO is mainly due to the free zinc ions and labile zinc complexes. The toxicity of nano-ZnO in the five media deceased as follows: ultrapure water > NaCl > MD > LB > PBS. The generation of precipitates (Zn(3)(PO(4))(2) in PBS) and zinc complexes (of zinc with citrate and amino acids in MD and LB, respectively) dramatically decreased the concentration of Zn(2+) ions, resulting in the lower toxicity in these media. Additionally, the isotonic and rich nutrient conditions improved the tolerance of E. coli to toxicants. Considering the dramatic difference of the toxicity of nano-ZnO in various aqueous media, the effect of water chemistry on the physicochemical properties of nanoparticles should be paid more attention in future nanotoxicity evaluations.

  7. The Fresenius Medical Care home hemodialysis system.

    PubMed

    Schlaeper, Christian; Diaz-Buxo, Jose A

    2004-01-01

    The Fresenius Medical Care home dialysis system consists of a newly designed machine, a central monitoring system, a state-of-the-art reverse osmosis module, ultrapure water, and all the services associated with a successful implementation. The 2008K@home hemodialysis machine has the flexibility to accommodate the changing needs of the home hemodialysis patient and is well suited to deliver short daily or prolonged nocturnal dialysis using a broad range of dialysate flows and concentrates. The intuitive design, large graphic illustrations, and step-by-step tutorial make this equipment very user friendly. Patient safety is assured by the use of hydraulic systems with a long history of reliability, smart alarm algorithms, and advanced electronic monitoring. To further patient comfort with their safety at home, the 2008K@home is enabled to communicate with the newly designed iCare remote monitoring system. The Aquaboss Smart reverse osmosis (RO) system is compact, quiet, highly efficient, and offers an improved hygienic design. The RO module reduces water consumption by monitoring the water flow of the dialysis system and adjusting water production accordingly. The Diasafe Plus filter provides ultrapure water, known for its long-term benefits. This comprehensive approach includes planning, installation, technical and clinical support, and customer service.

  8. A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Evans, Kurt B.; Schiffman, Robert L.; Deweese, C. Darrell; Prince, Michael E.

    1995-01-01

    Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

  9. Evaluation of cephamycins as supplements to selective agar for detecting Campylobacter spp. in chicken carcass rinses.

    PubMed

    Chon, Jung-Whan; Kim, Young-Ji; Kim, Hong-Seok; Kim, Dong-Hyeon; Kim, Hyunsook; Song, Kwang-Young; Sung, Kidon; Seo, Kun-Ho

    2016-04-16

    Although cefoperazone is the most commonly used antibiotic in Campylobacter-selective media, the distribution of cefoperazone-resistant bacteria such as extended-spectrum beta-lactamase (ESBL)-producing Escherichia coli is increasing. Here we evaluated the potential of cephamycins for use as supplements to improve modified charcoal-cefoperazone-deoxycholate agar (mCCDA) by replacing cefoperazone with the same concentrations (32 mg/L) of cefotetan (modified charcoal-cefotetan-deoxycholate agar, mCCtDA) and cefoxitin (modified charcoal-cefoxitin-deoxycholate agar, mCCxDA). In chicken carcass rinse samples, the number of mCCDA plates detecting for Campylobacter (18/70, 26%) was significantly lower than that of mCCtDA (42/70, 60%) or mCCxDA plates (40/70, 57%). The number of mCCDA plates (70/70, 100%) that were contaminated with non-Campylobacter species was significantly higher than that of mCCtDA (20/70, 29%) or mCCxDA plates (21/70, 30%). The most common competing species identified using mCCDA was ESBL-producing E. coli, while Pseudomonas species frequently appeared on mCCtDA and mCCxDA. Copyright © 2016. Published by Elsevier B.V.

  10. Effect of etch-and-rinse and self-etching adhesive systems on hardness uniformity of resin cements after glass fiber post cementation

    PubMed Central

    Grande da Cruz, Fernanda Zander; Grande, Christiana Zander; Roderjan, Douglas Augusto; Galvão Arrais, César Augusto; Bührer Samra, Adriana Postiglione; Calixto, Abraham Lincoln

    2012-01-01

    Objective To evaluate the effects of etch-and-rinse and self-etching adhesive systems on Vickers hardness (VHN) uniformity of dual-cured resin cements after fiber post cementation. Methods: Fifty glass fiber posts were cemented into bovine roots using the following cementing systems: Prime&Bond 2.1 Dual Cure and Enforce with light-activation (PBDC-LCEN); Prime&Bond 2.1 and Enforce with light-activation (PB-CLEN); Prime&Bond 2.1 Dual Cure and Enforce without light exposure (PBDC-SCEN); ED Primer and Panavia 21 (ED-SCPN); and Clearfil SE Bond and Panavia 21 (CF-SCPN). The roots were stored in distilled water for 72 h and transversely sectioned into thirds (coronal, medium, and apical). The VHN values of the resin cement layers were measured close to the post and to the dentin wall on the transversely sectioned flat surfaces. The results were analyzed by three-way repeated measures analysis of variance (ANOVA) and Tukey’s post-hoc test (pre-set alpha of 5%). Results: Most resin cements presented higher VHN values near the post than near the dentin wall. The ED-SCPN group showed the highest VHN values regardless of the root third, while the self-cured group PBDC-SCEN exhibited the lowest values. The resin cements from the light-activated groups PBDC-LCEN and PB-LCEN showed lower VHN values at the apical third than at the coronal third. The VHN values were not influenced by the root third in self-cured groups PBDC-SCEN, ED-SCPN, and ED-SCPN. Conclusion: Depending on the product, bonding agents might promote changes in hardness uniformity of resin cements after post cementation. PMID:22904652

  11. Rapid removal of bacterial endotoxin and natural organic matter in water by dielectric barrier discharge plasma: Efficiency and toxicity assessment.

    PubMed

    Zhang, Can; Fang, Zhendong; Liu, Wenjun; Tian, Fang; Bai, Miao

    2016-11-15

    Low-temperature plasma was used to control bacteria, endotoxins and natural organic matter (NOM) in water by a dielectric barrier discharge (DBD) device. Results indicate that DBD plasma has an obvious inactivation effect on various bacteria in water. The degree of inactivation from difficult to easy is as follows: Bacillus subtilis>Escherichia coli>Staphylococcus aureus. Activated ultrapure water treated using DBD plasma exhibited a sustained sterilization effect, but this sterilization effect decreased gradually after 1h. The total-endotoxin (free-endotoxin and bound-endotoxin) released by Escherichia coli during inactivation, as well as artificially simulated endotoxin in a control solution, was significantly controlled by DBD plasma. Both the metabolites that appeared after inactivation of microorganisms by plasma treatment, and the NOM in filtration effluent of a water treatment plant were well removed by DBD plasma if the treatment duration was sufficiently long. However, the acute toxicity increased significantly, and persisted for at least 2h, indicating that some long-life active substances were generated during the DBD process. Therefore, the removal of bacteria, endotoxins or NOM does not mean a safe water is produced. It is also important to eliminate the toxicity and byproducts produced during water treatment for the continuous promotion and industrial application of DBD plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. 40 CFR 421.206 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... mercury produced from batteries Lead 0.030 0.014 Mercury 0.016 0.006 (b) Acid wash and rinse water. PSNS... for monthly average mg/kg (pounds per million pounds) of mercury washed and rinsed Lead 0.00056 0.00026 Mercury 0.00030 0.00012 (c) Furnance wet air pollution control. PSNS for the Secondary Mercury...

  13. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  14. Dental caries and dental fluorosis at varying water fluoride concentrations.

    PubMed

    Heller, K E; Eklund, S A; Burt, B A

    1997-01-01

    The purpose of this study was to investigate the relationships between caries experience and dental fluorosis at different fluoride concentrations in drinking water. The impact of other fluoride products also was assessed. This study used data from the 1986-87 National Survey of US School-children. Fluoride levels of school water were used as an indicator of the children's water fluoride exposure. The use of fluoride drops, tablets, professional fluoride treatments, and school fluoride rinses were ascertained from caregiver questionnaires. Only children with a single continuous residence (n = 18,755) were included in this analysis. The sharpest declines in dfs and DMFS were associated with increases in water fluoride levels between 0 and 0.7 ppm F, with little additional decline between 0.7 and 1.2 ppm F. Fluorosis prevalence was 13.5 percent, 21.7 percent, 29.9 percent, and 41.4 percent for children who consumed < 0.3, 0.3 to < 0.7, 0.7 to 1.2, and > 1.2 ppm F water. In addition to fluoridated water, the use of fluoride supplements was associated with both lower caries and increased fluorosis. A suitable trade-off between caries and fluorosis appears to occur around 0.7 ppm F. Data from this study suggest that a reconsideration of the policies concerning the most appropriate concentrations for water fluoridation might be appropriate for the United States.

  15. Comparison of residual salivary fluoride retention using amine fluoride toothpastes in caries-free and caries-prone children.

    PubMed

    Nazzal, H; Duggal, M S; Kowash, M B; Kang, J; Toumba, K J

    2016-06-01

    This was to compare the salivary fluoride levels following tooth brushing with amine fluoride toothpastes containing three different concentrations of F (250 ppm F, 500 ppm F and 1250 ppm F) and to evaluate the effect of rinsing with water on the oral fluoride levels up to 90 min. A double blind randomised six-arm crossover study was conducted with 32 child participants. Patients were divided into two groups depending on their caries experience with caries-free group (n = 17, mean age = 72.9 months) and caries-prone group (n = 15, mean age = 69.6 months, mean dmfs = 12.3). Each participant brushed their teeth with a smear of dentifrice containing (250 ppm, 500 ppm and 1250 ppm F toothpastes) for 60 s. After spitting out the dentifrice/saliva slurry, participants either rinsed with water or did not rinse at all. Samples of whole mixed unstimulated saliva were collected at 0 (baseline), 1, 15, 30, 45, 60 and 90 mins post-brushing/rinsing. After completing the study on residual fluoride concentration it was found that caries was not a significant variable (p = 0.567) while every other variable was (all p values <0.001). Time, toothpaste F concentration and rinse had significant effects (p < 0.001). In general, higher residual salivary F concentrations were found with increased F concentration in toothpastes and when no rinsing was performed after brushing. The results of this study support the current recommendation of using toothpastes with >1000 ppm F concentration in children with an increased caries risk in addition to spitting excess toothpaste with no rinsing following brushing.

  16. Carbon capture by sorption-enhanced water-gas shift reaction process using hydrotalcite-based material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van Selow, E.R.; Cobden, P.D.; Verbraeken, P.A.

    2009-05-15

    A novel route for precombustion decarbonization is the sorption-enhanced water-gas shift (SEWGS) process. In this process carbon dioxide is removed from a synthesis gas at elevated temperature by adsorption. Simultaneously, carbon monoxide is converted to carbon dioxide by the water-gas shift reaction. The periodic adsorption and desorption of carbon dioxide is induced by a pressure swing cycle, and the cyclic capacity can be amplified by purging with steam. From previous studies is it known that for SEWGS applications, hydrotalcite-based materials are particularly attractive as sorbent, and commercial high-temperature shift catalysts can be used for the conversion of carbon monoxide. Tabletsmore » of a potassium promoted hydrotalcite-based material are characterized in both breakthrough and cyclic experiments in a 2 m tall fixed-bed reactor. When exposed to a mixture of carbon dioxide, steam, and nitrogen at 400{sup o}C, the material shows a breakthrough capacity of 1.4 mmol/g. In subsequent experiments the material was mixed with tablets of promoted iron-chromium shift catalyst and exposed to a mixture of carbon dioxide, carbon monoxide, steam, hydrogen, and nitrogen. It is demonstrated that carbon monoxide conversion can be enhanced to 100% in the presence of a carbon dioxide sorbent. At breakthrough, carbon monoxide and carbon dioxide simultaneously appear at the end of the bed. During more than 300 cycles of adsorption/reaction and desorption, the capture rate, and carbon monoxide conversion are confirmed to be stable. Two different cycle types are investigated: one cycle with a CO{sub 2} rinse step and one cycle with a steam rinse step. The performance of both SEWGS cycles are discussed.« less

  17. Efficacy of neutral electrolyzed water to inactivate Escherichia coli, Listeria monocytogenes, Pseudomonas aeruginosa, and Staphylococcus aureus on plastic and wooden kitchen cutting boards.

    PubMed

    Deza, M A; Araujo, M; Garrido, M J

    2007-01-01

    This study evaluated the efficacy of neutral electrolyzed water (NEW; 64.1 mg/liter of active chlorine) to reduce populations of Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and Listeria monocytogenes on plastic and wooden kitchen cutting boards. Its effectiveness was compared with that of a sodium hypochlorite solution (NaClO; 62.3 mg/liter of active chlorine). Inoculated portions of cutting boards were rinsed in either NEW or NaClO solutions, or deionized water (control). Plastic boards were rinsed for 1 min and wooden boards for 1 and 5 min. After each treatment, the surviving population of each strain was determined on the surface and in the soaking water. No significant difference (P > or = 0.05) was found between the final populations of each strain with regard to the treatment solutions (NEW or NaClO). However, a significant difference (P < or = 0.05) was revealed between surface materials after 1 min of washing. Whereas in plastic boards the initial bacterial populations were reduced by 5 log CFU/50 cm2, in wooden cutting boards they underwent a reduction of <3 log CFU/50 cm2. A 5-min exposure time yielded reductions of about 4 log CFU/50 cm2. The surviving populations of all bacteria in NEW and NaCIO washing solutions were <1 log CFU/ml after soaking both surfaces. This study revealed that NEW treatment is an effective method for reducing microbial contamination on plastic and wooden cutting boards. NEW efficacy was comparable to that of NaCIO, with the advantage of having a larger storage time.

  18. Efficacy of air/water syringe tip sterilization.

    PubMed

    Inger, M; Bennani, V; Farella, M; Bennani, F; Cannon, R D

    2014-03-01

    Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones. © 2014 Australian Dental Association.

  19. Colour preference between adults and children during a dental treatment session.

    PubMed

    Oner Ozdas, Didem; Kazak, Magrur

    2017-02-01

    It is evidently shown that colour has physical, psychological and sociological effects on human beings. There are many studies showing the effects of colours on brain activity. Colour preferences may change from childhood to adulthood and are significantly different in various age groups. The aim of this study was to evaluate the adults and children in their preference for mouthrinses in various colours under stress condition during a dental treatment session. 240 adults and 263 children were included in the study. Three transparent cups were filled with water, two of which were coloured green/pink rinsing by dissolving a tablet in the water. Cups were placed near the dental unit. During dental treatment sessions, patients were told to rinse their mouth with whichever cup they preferred. Preferred colour of cup, gender and age of patient, number of sessions were recorded. Data were statistically analysed by SPSS 15.0 programme and chi-square tests. Half of all cases preferred water. In adults, while females statistically significantly preferred water, males chose cups with coloured contents (p<0.01). Male adults preferred more than one rinsing solution in a dental treatment session. Children mostly preferred water. Even if adults preferred cups with coloured contents in multi-dental treatment sessions, children regularly preferred water (p<0.001). Female and male children mostly preferred water as a rinsing solution. Water was the most often choice for all patients. Both patients' gender and colours of cups affected choices made by adults and children. Female adults and children were not interested in trying colourful mouthrinses, while male adults were curious about trying colourful mouthrinses during dental treatment sessions under stress condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Toxicological Profile of Ultrapure 2,2′,3,4,4′,5,5′-Heptachlorbiphenyl (PCB 180) in Adult Rats

    PubMed Central

    Viluksela, Matti; Heikkinen, Päivi; van der Ven, Leo T. M.; Rendel, Filip; Roos, Robert; Esteban, Javier; Korkalainen, Merja; Lensu, Sanna; Miettinen, Hanna M.; Savolainen, Kari; Sankari, Satu; Lilienthal, Hellmuth; Adamsson, Annika; Toppari, Jorma; Herlin, Maria; Finnilä, Mikko; Tuukkanen, Juha; Leslie, Heather A.; Hamers, Timo; Hamscher, Gerd; Al-Anati, Lauy; Stenius, Ulla; Dervola, Kine-Susann; Bogen, Inger-Lise; Fonnum, Frode; Andersson, Patrik L.; Schrenk, Dieter; Halldin, Krister; Håkansson, Helen

    2014-01-01

    PCB 180 is a persistent non-dioxin-like polychlorinated biphenyl (NDL-PCB) abundantly present in food and the environment. Risk characterization of NDL-PCBs is confounded by the presence of highly potent dioxin-like impurities. We used ultrapure PCB 180 to characterize its toxicity profile in a 28-day repeat dose toxicity study in young adult rats extended to cover endocrine and behavioral effects. Using a loading dose/maintenance dose regimen, groups of 5 males and 5 females were given total doses of 0, 3, 10, 30, 100, 300, 1000 or 1700 mg PCB 180/kg body weight by gavage. Dose-responses were analyzed using benchmark dose modeling based on dose and adipose tissue PCB concentrations. Body weight gain was retarded at 1700 mg/kg during loading dosing, but recovered thereafter. The most sensitive endpoint of toxicity that was used for risk characterization was altered open field behavior in females; i.e. increased activity and distance moved in the inner zone of an open field suggesting altered emotional responses to unfamiliar environment and impaired behavioral inhibition. Other dose-dependent changes included decreased serum thyroid hormones with associated histopathological changes, altered tissue retinoid levels, decreased hematocrit and hemoglobin, decreased follicle stimulating hormone and luteinizing hormone levels in males and increased expression of DNA damage markers in liver of females. Dose-dependent hypertrophy of zona fasciculata cells was observed in adrenals suggesting activation of cortex. There were gender differences in sensitivity and toxicity profiles were partly different in males and females. PCB 180 adipose tissue concentrations were clearly above the general human population levels, but close to the levels in highly exposed populations. The results demonstrate a distinct toxicological profile of PCB 180 with lack of dioxin-like properties required for assignment of WHO toxic equivalency factor. However, PCB 180 shares several toxicological

  1. A straightforward method for measuring the range of apparent density of microplastics.

    PubMed

    Li, Lingyun; Li, Mengmeng; Deng, Hua; Cai, Li; Cai, Huiwen; Yan, Beizhan; Hu, Jun; Shi, Huahong

    2018-10-15

    Density of microplastics has been regarded as the primary property that affect the distribution and bioavailability of microplastics in the water column. For measuring the density of microplastis, we developed a simple and rapid method based on density gradient solutions. In this study, we tested four solvents to make the density gradient solutions, i.e., ethanol (0.8 g/cm 3 ), ultrapure water (1.0 g/cm 3 ), saturated NaI (1.8 g/cm 3 ) and ZnCl 2 (1.8 g/cm 3 ). Density of microplastics was measured via observing the float or sink status in the density gradient solutions. We found that density gradient solutions made from ZnCl 2 had a larger uncertainty in measuring density than that from NaI, most likely due to a higher surface tension of ZnCl 2 solution. Solutions made from ethanol, ultrapure water, and NaI showed consistent density results with listed densities of commercial products, indicating that these density gradient solutions were suitable for measuring microplastics with a density range of 0.8-1.8 g/cm 3 . Copyright © 2018 Elsevier B.V. All rights reserved.

  2. High salinity leads to accumulation of soil organic carbon in mangrove soil.

    PubMed

    Kida, Morimaru; Tomotsune, Mitsutoshi; Iimura, Yasuo; Kinjo, Kazutoshi; Ohtsuka, Toshiyuki; Fujitake, Nobuhide

    2017-06-01

    Although mangrove forests are one of the most well-known soil organic carbon (SOC) sinks, the mechanism underlying SOC accumulation is relatively unknown. High net primary production (NPP) along with the typical bottom-heavy biomass allocation and low soil respiration (SR) have been considered to be responsible for SOC accumulation. However, an emerging paradigm postulates that SR is severely underestimated because of the leakage of dissolved inorganic carbon (DIC) in groundwater. Here we propose a simple yet unique mechanism for SOC accumulation in mangrove soils. We conducted sequential extraction of water extractable organic matter (WEOM) from mangrove soils using ultrapure water and artificial seawater, respectively. A sharp increase in humic substances (HS) concentration was observed only in the case of ultrapure water, along with a decline in salinity. Extracted WEOM was colloidal, and ≤70% of it re-precipitated by the addition of artificial seawater. These results strongly suggest that HS is selectively flocculated and maintained in the mangrove soils because of high salinity. Because sea salts are a characteristic of any mangrove forest, high salinity may be one of mechanisms underlying SOC accumulation in mangrove soils. Copyright © 2017. Published by Elsevier Ltd.

  3. Transport of E. coli D21g with runoff water under different solution chemistry conditions and surface slopes

    USDA-ARS?s Scientific Manuscript database

    Tracer and indicator microbe runoff experiments were conducted to investigate the influence of solution chemistry on the transport, retention, and release of Escherichia coli D21g. Experiments were conducted in a chamber (2.25 m long, 0.15 m wide, and 0.16 m high) packed with ultrapure quartz sand (...

  4. Plaque fluoride concentrations in a community without water fluoridation: effects of calcium and use of a fluoride or placebo dentifrice.

    PubMed

    Whitford, G M; Buzalaf, M A R; Bijella, M F B; Waller, J L

    2005-01-01

    The results of a recent study by Whitford et al. [Caries Res 2002;36:256-265] with subjects whose drinking water was fluoridated led to two major conclusions: (1) Compared to the use of a placebo dentifrice, plaque fluoride concentrations ([F]) throughout much of the day are not significantly increased by the use of an F dentifrice but (2) they are positively related to plaque [Ca] (p = 0.0001). The present double-blind, double-crossover study with 16 subjects used the same protocol and was done to: (1) determine the effects of the use of an F dentifrice on salivary and plaque [F] in a community without water fluoridation and (2) further examine the relationship between plaque [Ca] and [F]. Following the use of an F dentifrice or placebo for one week, whole saliva and plaque were collected 1.0 and 12 h after the last use of the products. The study was repeated to include rinsing with a 20 mmol/l CaCl(2) solution immediately before the use of the dentifrices. The CaCl(2) rinse had only minor effects on salivary [Ca] and [F] and none on the plaque concentrations. Unlike the results found in the fluoridated community, all salivary and plaque [F] associated with the use of the F dentifrice were significantly higher than those associated with the use of the placebo. The results suggest that the cariostatic effectiveness of an F dentifrice should be greater in areas without water fluoridation. As noted previously, plaque [F] were positively related to plaque [Ca] (p = 0.0001). Copyright (c) 2005 S. Karger AG, Basel.

  5. Micro solid-phase derivatization analysis of low-molecular mass aldehydes in treated water by micellar electrokinetic chromatography.

    PubMed

    Fernández-Molina, José María; Silva, Manuel

    2014-03-01

    A MEKC method was developed for the determination of aliphatic and aromatic low-molecular mass aldehydes (LMMAs) in treated water samples. The method involves the precapillary derivatization and extraction of the aldehydes on a Telos™ENV μ-SPE column impregnated with 2,4-dinitrophenylhydrazine . After elution of the hydrazones with ACN, the derivatives were analyzed using MEKC-DAD. Resolution of the MEKC procedure was studied by changing the pH and the concentration of the buffer, the type, and the concentration of surfactant, and the organic modifier content in the BGE. A running buffer consisting of a phosphate buffer (pH 7.2, 75 mM) with CTAB (50 mM) and ACN (30%) gave the best results. Linearity was established over the concentration range 0.5-500 μg/L and LODs from 65 to 775 ng/L; the interday precision was expressed as the RSD of the aldehydes ranging from 6.6 to 8.4%. Matrix effects were shown to be negligible by comparing the response factors obtained in ultrapure and treated waters. Aldehydes were readily determined at 1.1-8.4 μg/L levels in ozonated and chlorinated water samples, the method proposed being the first CE contribution developed for the systematic analysis of both aliphatic and aromatic LMMAs in water samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Development and application of a sol-gel immunosorbent-based method for the determination of isoproturon in surface water.

    PubMed

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-01-13

    An immunosorbent was fabricated by encapsulation of monoclonal anti-isoproturon antibodies in sol-gel matrix. The immunosorbent-based loading, rinsing and eluting processes were optimized. Based on these optimizations, the sol-gel immunosorbent (SG-IS) selectively extracted isoproturon from an artificial mixture of 68 pesticides. In addition to this high selectivity, the SG-IS proved to be reusable. The SG-IS was combined with liquid chromatography-tandem mass spectrometry (LC-MS-MS) to determine isoproturon in surface water, and the linear range was up to 2.2 microg/l with correlation coefficient higher than 0.99 and relative standard deviation (RSD) lower than 5% (n=8). The limit of quantitation (LOQ) for 25-ml surface water sample was 5 ng/l.

  7. Soap is not enough: handwashing practices and knowledge in refugee camps, Maban County, South Sudan.

    PubMed

    Phillips, Raina M; Vujcic, Jelena; Boscoe, Andrew; Handzel, Thomas; Aninyasi, Mark; Cookson, Susan T; Blanton, Curtis; S Blum, Lauren; Ram, Pavani K

    2015-01-01

    Refugees are at high risk for communicable diseases due to overcrowding and poor water, sanitation, and hygiene conditions. Handwashing with soap removes pathogens from hands and reduces disease risk. A hepatitis E outbreak in the refugee camps of Maban County, South Sudan in 2012 prompted increased hygiene promotion and improved provision of soap, handwashing stations, and latrines. We conducted a study 1 year after the outbreak to assess the knowledge, attitudes, and practices of the refugees in Maban County. We conducted a cross sectional survey of female heads of households in three refugee camps in Maban County. We performed structured observations on a subset of households to directly observe their handwashing practices at times of possible pathogen transmission. Of the 600 households interviewed, nearly all had soap available and 91 % reported water was available "always" or "sometimes". Exposure to handwashing promotion was reported by 85 % of the respondents. Rinsing hands with water alone was more commonly observed than handwashing with soap at critical handwashing times including "before eating" (80 % rinsing vs. 7 % washing with soap) and "before preparing/cooking food" (72.3 % vs 23 %). After toilet use, 46 % were observed to wash hands with soap and an additional 38 % rinsed with water alone. Despite intensive messaging regarding handwashing with soap and access to soap and water, rinsing hands with water alone rather than washing hands with soap remains more common among the refugees in Maban County. This practice puts them at continued risk for communicable disease transmission. Qualitative research into local beliefs and more effective messaging may help future programs tailor handwashing interventions.

  8. Interaction between Bisphosphonates and Mineral Water: Study of Oral Risedronate Absorption in Rats.

    PubMed

    Itoh, Akihisa; Akagi, Yuuki; Shimomura, Hitoshi; Aoyama, Takao

    2016-01-01

    Bisphosphonates are antiosteoporotic agents prescribed for patients with osteoporosis. Drug package inserts for bisphosphonate supplements indicate that their bioavailability is reduced by high levels of metal cations (Ca(2+), Mg(2+), etc.). However, standards for these cations in water used for taking risedronate have not been defined. Here, we examined the effect of calcium and magnesium in mineral waters on the bioavailability of the third-generation bisphosphonate, risedronate, following oral administration in rats. As risedronate is unchanged and eliminated renally, risedronate absorption was estimated from the amount excreted in the urine. Risedronate was dissolved in mineral water samples and administered orally at 0.35 mg/kg. Urine samples were collected for 24 h after dosing. Risedronate was extracted from urine using ion-pair solid-phase cartridges and quantified by HPLC with UV detection (262 nm). Cumulative recovery of risedronate was calculated from the amount excreted in the urine. The 24-h recovery of risedronate from evian® (0.32±0.02% [mean±standard deviation (S.D.)], n=4) and Contrex(®) (0.22±0.05%) mineral waters was significantly lower than that from tap water (0.47±0.04%, p<0.01). Absorption of risedronate in calcium chloride and magnesium chloride aqueous solutions of the same hardness (822 mg/L) was 54% (0.27±0.04%) and 12% (0.51±0.08%) lower, respectively, compared with ultrapure water; suggesting that absorption of risedronate declines as the calcium concentration of mineral waters increases. Consumption of mineral waters containing high levels of calcium (80 mg/L or above), such as evian® and Contrex(®), is therefore not recommended when taking risedronate.

  9. Photolysis of 2,4,6-trinitrotoluene in seawater and estuary water: Impact of pH, temperature, salinity, and dissolved organic matter.

    PubMed

    Luning Prak, Dianne J; Breuer, James E T; Rios, Evelyn A; Jedlicka, Erin E; O'Sullivan, Daniel W

    2017-01-30

    The influence of salinity, pH, temperature, and dissolved organic matter on the photolysis rate of 2,4,6-trinitrotoluene (TNT) in marine, estuary, and laboratory-prepared waters was studied using a Suntest CPS+® solar simulator equipped with optical filters. TNT degradation rates were determined using HPLC analysis, and products were identified using LC/MS. Minimal or no TNT photolysis occurred under a 395-nm long pass filter, but under a 295-nm filter, first-order TNT degradation rate constants and apparent quantum yields increased with increasing salinity in both natural and artificial seawater. TNT rate constants increased slightly with increasing temperature (10 to 32°C) but did not change significantly with pH (6.4 to 8.1). The addition of dissolved organic matter (up to 5mg/L) to ultrapure water, artificial seawater, and natural seawater increased the TNT photolysis rate constant. Products formed by TNT photolysis in natural seawater were determined to be 2,4,6-trinitrobenzaldehyde, 1,3,5-trinitrobenzene, 2,4,6-trinitrobenzoic acid, and 2-amino-4,6-dinitrobenzoic acid. Published by Elsevier Ltd.

  10. Comparison of ozone and chlorine in low concentrations as sanitizing agents of chicken carcasses in the water immersion chiller.

    PubMed

    Trindade, Marco Antonio; Kushida, Marta Mitsui; Montes Villanueva, Nilda D; dos Santos Pereira, David Uenaka; De Oliveira, Andcelso Eduardo Lins

    2012-06-01

    The aim of this study was to investigate the effects of the use of chlorine or ozone as sanitizing agents in the water of chicken immersion chilling, using the residual levels usually applied in Brazil (1.5 ppm), comparing the effects of these treatments on the microbiological, physicochemical, and sensory characteristics of carcasses. Chicken carcasses were chilled in water (4°C) with similar residual levels of ozone and chlorine until reaching temperatures below 7°C (around 45 min). The stability of carcasses was assessed during 15 days of storage at 2 ± 1°C. Microbiological, surface color (L*, a*, b* parameters), pH value, lipid oxidation (thiobarbituric acid reactive substances index), and sensory evaluation (on a 9-point hedonic scale for odor and appearance) analyses were carried out. The presence of Salmonella was not detected, coagulase-positive staphylococci counts were below 10(2) CFU/ml of rinse fluid, and Escherichia coli and total coliform counts were below 10(5) CFU/ml of rinse fluid until the end of the storage period for both treatments. Psychrotrophic microorganism counts did not differ (P > 0.05) between chlorine and ozone treatments, and both values were near 10(9) CFU/ml of rinse fluid after 15 days at 4 ± 1°C. pH values did not differ between treatments (P > 0.05) or during the storage period (P > 0.05). In addition, neither chlorine nor ozone treatment showed differences (P > 0.05) in the lipid oxidation of carcasses; however, the thiobarbituric acid reactive substances index of both treatments increased (P ≤ 0.05) during the storage period, reaching values of approximately 0.68 mg of malonaldehyde per kg. Samples from both treatments did not differ (P > 0.05) in their acceptance scores for odor and overall appearance, but in the evaluation of color, ozone showed an acceptance score significantly higher (P ≤ 0.05) than that for the chlorine treatment. In general, under the conditions tested, ozone showed results similar to the

  11. Measurement of Polycyclic Aromatic Hydrocarbons in Airborne Particulate Matter at Low Concentrations

    DTIC Science & Technology

    2012-03-01

    Soil & Water Colorimetric (diphenylcarbazide) 7199 Hexavalent Chromium by Ion Chromatography 218.6 Low level chelation & extraction NATTS...Hexane:Dichloromethane:Methanol Dionex ASE 200 Sample Concentration Evaporation in Ultrapure Nitrogen Stream Zymark Turbovap Solid Phase Extraction Supelco Custom...Glass Silica SPE Cartridge 1% Dichloromethane + 1% Acetone in Hexane GCMS Analysis Conventional Splitless Injection Selective Ion Monitoring

  12. Biocolloid transport in water saturated columns packed with sand

    NASA Astrophysics Data System (ADS)

    Syngouna, V. I.; Chrysikopoulos, C.

    2010-12-01

    Protection of groundwater supplies from microbial contamination necessitates a solid understanding of the factors controlling the migration and retention of pathogenic organisms (biocolloids) in the subsurface. The transport behavior of three waterborne pathogens (Escherichia coli, MS2, and ΦΧ174) was investigated using laboratory-scale columns packed with clean quartz sand. Various grain sizes and pore water velocities were examined. Though coliform bacteria and coliphages are used worldwide to indicate fecal pollution of groundwater, the various parameters controlling the transport of Escherichia coli MS2 and ΦΧ174 in the subsurface are not fully understood. In this study, the attachment behavior of Escherichia coli, MS2, and ΦΧ174 onto ultra-pure quartz sand were evaluated. The mass recoveries of the three biocolloids examined were found to be proportional to the sand size. The observed mass recoveries were in the order: Escherichia coli > ΦΧ174 > MS2. To assess the importance of biocolloid attachment, the single collector removal efficiency, and the collision efficiency were quantified using the classical colloid filtration theory. Our results indicate that the secondary energy minimum plays an important role in biocolloid deposition even for smaller biocolloid particles (e.g. viruses).

  13. Further damage induced by water in micro-indentations in phosphate laser glass

    NASA Astrophysics Data System (ADS)

    Yu, Jiaxin; Jian, Qingyun; Yuan, Weifeng; Gu, Bin; Ji, Fang; Huang, Wen

    2014-02-01

    Using a microhardness tester, artificial flaws were made by micro-indentation in N31 Nd-doped phosphate laser glass. Indentation fracture toughness, KIC, was estimated as 0.45-0.53 MPa m1/2 from these indentations. The glasses with indentations were then immersed in ultrapure water to investigate further water-induced damage of these indentations. Stress-enhanced hydrolysis leads to the propagations of radial crack, lateral cracks and microcracks in the subsurface. These crack propagations therefore cause deformation in subsurface to form annular reflections regions around the indentations and further material collapse within imprints. After the residual stresses are exhausted, the leaching plays a more dominated role in glass corrosion in the further immersion. After immersion, the material structure slackens around micro-indentation, which decreases the contact stiffness and results in a lower nano-hardness. For the surface far away from flaws, water immersion presents a weak effect on the near-surface mechanical since the matrix leaching in phosphate glass restricts the formation of hydration layer. During first 20 min immersion, due to higher chemical activity and lower fracture toughness, the radial cracks show a faster propagation in phosphate glass compared with that in K9 silicate glass. For further immersion, crack healing occurs in silicate glass but not in phosphate glass. Analysis shows that the formation of hydration layer on crack walls plays an important role in crack healing in glasses.

  14. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  15. Drug loss while crushing tablets: Comparison of 24 tablet crushing devices

    PubMed Central

    Thong, Min Yew; Manrique, Yady J.

    2018-01-01

    This study investigated 24 tablet crushing devices for drug loss using different methods to recover the crushed tablet. 24 devices were compared: 3 with disposable cups, 6 with disposable bags, 12 without separate vessels and 3 types of mortar and pestle. One paracetamol tablet was crushed and recovered by tapping the powder out. Where appropriate, depending on crusher size and manufacturer instructions, the powder was also recovered by mixing with water or food. Paracetamol recovery (quantity that can be delivered to a patient) and leftover (quantity remaining in the device) were measured using a validated UV method and the entire experiment was replicated 3 times. Drug recovery ranged from 86.7–98.1% when the crushed tablet was tapped out of the crushers (average loss 5.8%). Significant losses were measured for 18 crushers, particularly manually operated hand-twist crushers with a serrated crushing surface, and some devices with disposable bags or cups. Rinsing the crushed powder with water once resulted in an average of 24.2% drug loss, and this was reduced to 4.2% after a second rinse. If crushing is unavoidable, maximizing medication delivery to the patient is essential. Rinsing twice resulted in similar paracetamol recovery to tapping the powder out; however only water rinses have the potential for direct consumption by the patient, minimizing drug loss across the entire crushing and transfer process. PMID:29494695

  16. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples.

    PubMed

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac

    2014-05-01

    In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry

    PubMed Central

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-01-01

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L−1 (S/N = 3) in lake water samples and ~0.5 μg·L−1 in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10–1000 μg·L−1. Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L−1 gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples. PMID:27529262

  18. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry.

    PubMed

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-08-11

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L(-1) (S/N = 3) in lake water samples and ~0.5 μg·L(-1) in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10-1000 μg·L(-1). Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L(-1) gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples.

  19. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  20. Efficacy of detergents in removing Salmonella and Shigella spp. from the surface of fresh produce.

    PubMed

    Raiden, Renee M; Sumner, Susan S; Eifert, Joseph D; Pierson, Merle D

    2003-12-01

    Fresh produce has been implicated in several foodborne disease outbreaks. Produce surfaces can be primary sites of contamination during production and handling. One approach to reduce contamination is to treat fresh produce with rinsing agents. In this study, different detergent agents were used at 22 and 40 degrees C to determine their efficacy in removing Salmonella and Shigella spp. from the surfaces of strawberries, tomatoes, and green-leaf lettuce. Produce was inoculated at 22 degrees C with a cocktail of nalidixic acid-resistant organisms (6 to 6.5 log CFU/ml). After air drying for 1 h, samples were rinsed with either 0.1% Tween 80, 0.1% sodium lauryl sulfate (SLS), or water (control) at 22 or 40 degrees C. Rinse solutions were spiral plated onto tryptic soy agar supplemented with 50 mg of nalidixic acid per liter. In trials involving strawberries and lettuce, Salmonella and Shigella were removed at levels of 4 and 3 log CFU/ml, respectively, except from Salmonella-inoculated strawberries rinsed with SLS, for which minimal removal rates were 1.5 log CFU/ml at 22 degrees C and < 1 log CFU/ml at 40 degrees C. When whole strawberries were analyzed after rinsing with SLS, few organisms were recovered. This result suggests that SLS may have a lethal or sublethal effect on Salmonella, especially when a 40 degrees C solution is used. Salmonella and Shigella removal rates for tomatoes were 1 and 1.5 log CFU/ml lower, respectively, than those for strawberries or lettuce. Overall, detergents were no more effective in removing organisms from produce than water was. The detergents examined would not constitute effective overall produce rinse treatments.

  1. Application of CWPO to the treatment of pharmaceutical emerging pollutants in different water matrices with a ferromagnetic catalyst.

    PubMed

    Munoz, Macarena; Mora, Francisco J; de Pedro, Zahara M; Alvarez-Torrellas, Silvia; Casas, Jose A; Rodriguez, Juan J

    2017-06-05

    CWPO has proved to be effective for the treatment of representative pharmaceuticals (sulfamethoxazole, atenolol, metronidazole, diltiazem, trimethoprim and ranitidine) in different water matrices (ultrapure water, surface water, WWTP effluent and hospital wastewater). Complete removal of the pollutants and the aromatic intermediates was achieved using the stoichiometric dose of H 2 O 2 , a catalyst (Fe 3 O 4 /γ-Al 2 O 3 ) load of 2gL -1 , pH 3 and temperature of 50-75°C. Accordingly, the ecotoxicity was reduced to negligible values. The degradation was faster when the pharmaceuticals were together, being the reaction time for the elimination of the most refractory species (metronidazole) shortened from 4h to 1h. The mineralization of the drugs was fairly different, being the most reactive species those containing several aromatic rings (X TOC ∼80%) and the most refractory that bearing an imidazolium ring (X TOC ∼35%). The water matrix affected the kinetics of the process but in all cases complete conversion of the drugs was reached within 1h. The presence of dissolved organic matter (surface water) seemed to promote drugs degradation while the occurrence of inorganic ions (real WTTP and hospital effluents) partially inhibited it due to scavenging effects. Remarkably, the process was successfully operated at the typical concentrations of main micropollutant sources (μgL -1 ). Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparison of reverse transcriptase PCR, reverse transcriptase loop-mediated isothermal amplification, and culture-based assays for Salmonella detection from pork processing environments.

    PubMed

    Techathuvanan, Chayapa; Draughon, Frances Ann; D'Souza, Doris Helen

    2011-02-01

    Novel rapid Salmonella detection assays without the need for sophisticated equipment or labor remain in high demand. Real-time reverse transcriptase PCR (RT-PCR) assays, though rapid and sensitive, require expensive thermocyclers, while a novel RT loop-mediated isothermal amplification (RT-LAMP) method requires only a simple water bath. Our objective was to compare the detection sensitivity of Salmonella Typhimurium from the pork processing environment by RT-LAMP, RT-PCR, and culture-based assays. Carcass and surface swabs and carcass rinses were obtained from a local processing plant. Autoclaved carcass rinses (500 ml) were spiked with Salmonella Typhimurium and filtered. Filters were placed in stomacher bags containing tetrathionate broth (TTB) and analyzed with or without 10-h enrichment at 37 °C. Natural swabs were stomached with buffered peptone water, and natural carcass rinses were filtered, preenriched, and further enriched in TTB. Serially-diluted enriched samples were enumerated by spread plating on xylose lysine Tergitol 4 agar. RNA was extracted from 5 ml of enriched TTB with TRIzol. RT-LAMP assay using previously described invA primers was conducted at 62 °C for 90 min in a water bath with visual detection and by gel electrophoresis. SYBR Green I-based-real-time RT-PCR was carried out with invA primers followed by melt temperature analysis. The results of RT-LAMP detection for spiked carcass rinses were comparable to those of RT-PCR and cultural plating, with detection limits of 1 log CFU/ml, although they were obtained significantly faster, within 24 h including preenrichment and enrichment. RT-LAMP showed 4 of 12 rinse samples positive, while RT-PCR showed 1 of 12 rinse samples positive. For swabs, 6 of 27 samples positive by RT-LAMP and 5 of 27 by RT-PCR were obtained. This 1-day RT-LAMP assay shows promise for routine Salmonella screening by the pork industry. Copyright ©, International Association for Food Protection

  3. Examination of the steps leading up to the physical developer process for developing fingerprints.

    PubMed

    Wilson, Jeffrey Daniel; Cantu, Antonio A; Antonopoulos, George; Surrency, Marc J

    2007-03-01

    This is a systematic study that examines several acid prewashes and water rinses on paper bearing latent prints before its treatment with a silver physical developer. Specimens or items processed with this method are usually pretreated with an acid wash to neutralize calcium carbonate from the paper before the treatment with a physical developer. Two different acids at varying concentrations were tested on fingerprints. Many different types of paper were examined in order to determine which acid prewash was the most beneficial. Various wash times as well as the addition of a water rinse step before the development were also examined. A pH study was included that monitored the acidity of the solution during the wash step. Scanning electron microscopy was used to verify surface calcium levels for the paper samples throughout the experiment. Malic acid at a concentration of 2.5% proved to be an ideal acid for most papers, providing good fingerprint development with minimal background development. Water rinses were deemed unnecessary before physical development.

  4. Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?

    PubMed

    Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino

    2010-12-01

    Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.

  5. In Situ Antibacterial Activity of Essential Oils with and without Alcohol on Oral Biofilm: A Randomized Clinical Trial

    PubMed Central

    Quintas, Victor; Prada-López, Isabel; Carreira, María J.; Suárez-Quintanilla, David; Balsa-Castro, Carlos; Tomás, Inmaculada

    2017-01-01

    Currently, there is little evidence on the in situ antibacterial activity of essential oils (EO) without alcohol. This study aimed to evaluate in situ the substantivity and antiplaque effect on the plaque-like biofilm (PL-biofilm) of two solutions, a traditional formulation that contains EO with alcohol (T-EO) and an alcohol-free formulation of EO (Af-EO). Eighteen healthy adults performed a single mouthwash of: T-EO, Af-EO, and sterile water (WATER) after wearing an individualized disk-holding splint for 2 days. The bacterial viability (BV) and thickness of the PL-biofilm were quantified at baseline, 30 s, and 1, 3, 5, and 7 h post-rinsing (Test 1). Subsequently, each volunteer wore the splint for 4 days, applying two daily mouthwashes of: T-EO, Af-EO, and WATER. The BV, thickness, and covering grade (CG) of the PL-biofilm were quantified (Test 2). Samples were analyzed by confocal laser scanning microscopy after staining with the LIVE/DEAD® BacLight™ solution. To conduct the computations of the BV automatically, a Matlab toolbox called Dentius Biofilm was developed. In test 1, both EO antiseptics had a similar antibacterial effect, reducing BV after a single rinse compared to the WATER, and keeping it below baseline levels up to 7 h post-rinse (P < 0.001). The mean thickness of the PL-biofilm after rinsing was not affected by any of the EO formulations and ranged from 18.58 to 20.19 μm. After 4 days, the T-EO and Af-EO solutions were significantly more effective than the WATER, reducing the BV, thickness, and CG of the PL-biofilm (P < 0.001). Although, both EO antiseptics presented a similar bactericidal activity, the Af-EO rinses led to more significant reductions in the thickness and CG of the PL-biofilm than the T-EO rinses (thickness = 7.90 vs. 9.92 μm, P = 0.012; CG = 33.36 vs. 46.61%, P = 0.001). In conclusion, both essential oils antiseptics had very high immediate antibacterial activity and substantivity in situ on the 2-day PL-biofilm after a single

  6. [A PhD completed. Prevention and treatment of periodontal diseases and bad breath].

    PubMed

    van der Sluijs, E; Slot, D E; van der Weijden, G A

    2018-01-01

    Rinsing the mouth with water, or brushing with a dry toothbrush, does not contribute to an improvement in plaque removal during toothbrushing, nor does brushing according to a specific brushing regimen. Rinsing with water or drinking water has an immediate effect on bad morning breath. The combination of toothbrushing, tongue cleaning and a mouthwash has an effect on bad morning breath after 24 hours, in contrast with brushing with toothpaste only. The use of mouthwash with the specific ingredients chlorhexidine and essential oils has a positive effect on the reduction of gingivitis. The use of similar mouthwashes as a cooling solution in an ultrasonic device has no added effect on treatment results among periodontal patients. Water is an effective cooling solution.

  7. Producing standard damaged DNA samples by heating: pitfalls and suggestions.

    PubMed

    Fattorini, Paolo; Marrubini, Giorgio; Bonin, Serena; Bertoglio, Barbara; Grignani, Pierangela; Recchia, Elisa; Pitacco, Paola; Procopio, Francesca; Cantoni, Carolina; Pajnič, Irena Zupanič; Sorçaburu-Cigliero, Solange; Previderè, Carlo

    2018-05-15

    Heat-mediated hydrolysis of DNA is a simple and inexpensive method for producing damaged samples in vitro. Despite heat-mediated DNA hydrolysis is being widely used in forensic and clinical validation procedures, the lack of standardized procedures makes it impossible to compare the intra and inter-laboratory outcomes of the damaging treatments. In this work, a systematic approach to heat induced DNA hydrolysis was performed at 70 °C for 0-18 h to test the role both of the hydrolysis buffer and of the experimental conditions. Specifically, a trial DNA sample, resuspended in three different media (ultrapure water, 0.1% DEPC-water and, respectively, TE) was treated both in Eppendorf tubes ("Protocol P") and in Eppendorf tubes provided with screwcaps ("Protocol S"). The results of these comparative tests were assessed by normalization of the qPCR results. DEPC-water increased the degradation of the samples up to about 100 times when compared to the ultrapure water. Conversely, the TE protected the DNA from degradation whose level was about 1700 times lower than in samples treated in ultrapure water. Even the employment of the "Protocol S" affected the level of degradation, by consistently increasing it (up to about 180 times in DEPC-water). Thus, this comparative approach showed that even seemingly apparently trivial and often underestimated parameters modify the degradation level up to 2-3 orders of magnitude. The chemical-physical reasons of these findings are discussed together with the role of potential factors such as enhanced reactivity of CO 2 , ROS, NO x and pressure, which are likely to be involved. Since the intra and inter-laboratory comparison of the outcomes of the hydrolytic procedure is the first step toward its standardization, the normalization of the qPCR data by the UV/qPCR ratio seems to be the simplest and most reliable way to allow this. Finally, the supplying (provided with the commercial qPCR kits) of a DNA sample whose degree of

  8. Demonstration of acid and water recovery systems: Applicability and operational challenges in Indian metal finishing SMEs.

    PubMed

    Balakrishnan, M; Batra, R; Batra, V S; Chandramouli, G; Choudhury, D; Hälbig, T; Ivashechkin, P; Jain, J; Mandava, K; Mense, N; Nehra, V; Rögener, F; Sartor, M; Singh, V; Srinivasan, M R; Tewari, P K

    2018-07-01

    Diffusion dialysis, acid retardation and nanofiltration plants were acquired from Europe and demonstrated in several Indian metal finishing companies over a three year period. These companies are primarily small and medium enterprises (SMEs). Free acid recovery rate from spent pickling baths using diffusion dialysis and retardation was in the range of 78-86% and 30-70% respectively. With nanofiltration, 80% recovery rate of rinse water was obtained. The demonstrations created awareness among the metal finishing companies to reuse resources (acid/water) from the effluent streams. However, lack of efficient oil separators, reliable chemical analysis and trained personnel as well as high investment cost limit the application of these technologies. Local manufacturing, plant customization and centralized treatment are likely to encourage the uptake of such technologies in the Indian metal finishing sector. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Extraction of chemical warfare agents from water with hydrophilic-lipophilic balance and C18 cartridges: comparative study.

    PubMed

    Kanaujia, Pankaj K; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2007-01-19

    Efficient extraction of chemical warfare agents (CWAs) from water is essential before subjecting them to gas chromatographic and spectral analysis aiming towards verification of the Chemical Weapons Convention (CWC). It requires development of fast, reliable, simple and reproducible sample preparation of CWAs from water which is likely to be contaminated during deliberate or inadvertent spread of CWAs. This work describes development of a solid-phase extraction method using hydrophilic-lipophilic balance (HLB) cartridges for extraction of CWAs from water. The extraction efficiencies of HLB and C18 cartridges were compared and the results revealed that HLB sorbents performed better. Extracts were analyzed by gas chromatography-mass spectrometry. Extraction parameters, such as extraction solvent, its volume and rinsing solvent were optimized. Best recoveries of target analytes were obtained using 1mL methanol and limits of detection were achieved up to 0.05microg/mL with dichloromethane. Precision of the method was found to be less than 9.2% RSD.

  10. Development of Electrically Conductive Transparent Coatings for Acrylic Plastic

    DTIC Science & Technology

    1952-12-01

    after drying, but increased to 4,000 megoihms/square after 16 hours. 4. Polyacrylic-polyamine Cop-lyrrvrs Aqueous solutions of polymethacrylic acid ...methacrylic acid -methyl methaerylate copolymer re•I. The composite material, i. e., the acrylic and applied coating, retains essentially all the original...ation in 5%, NaOH solution for 5 minutes, rinsed in distilled water, immersed with agitation in 1516 nitric acid for 3 minutes and finally rinsed well

  11. Effects of fixed orthodontic treatment and two new mouth rinses on gingival health: A prospective cohort followed by a single-blind placebo-controlled randomized clinical trial.

    PubMed

    Sobouti, Farhad; Rakhshan, Vahid; Heydari, Mohaddeseh; Keikavusi, Shohreh; Dadgar, Sepideh; Shariati, Mahsa

    2018-03-01

    Routine brushing protocols might not suffice to reduce the increased plaque accumulation in orthodontic patients. Antimicrobial mouth rinses are favorable in this regard. This two-phase study evaluated the effects of orthodontic treatment and the application of two mouthwashes not studied before on oral health indices. In this two-phase study (a prospective cohort followed by a parallel randomized controlled trial), plaque index (PI), gingival index (GI), gingival bleeding index (GBI), and pocket probing depth (PPD) were measured in 54 orthodontic patients before orthodontic treatment and 4 months later. Then patients were randomized into three groups of mouthrinses: Persica (herbal), Ortho-Kin (containing diluted chlorhexidine), and Placebo (n=18×3). The effects of orthodontic treatment and mouthrinses were analyzed statistically (α=0.05). All the 4 indices increased between the baseline and 4th month of treatment (P values<0.01, paired t-test). They decreased back to baseline levels or below them, after one month of mouthwash application (P values<0.002). Both mouthwashes showed therapeutic effects compared to placebo in terms of PI and GBI. In the case of GI, only Persica showed significantly better results compared to placebo. Regarding PPD, only Ortho-Kin acted better than placebo (P values≤0.05, Tukey). Lack of positive control (regular chlorhexidine mouth rinse) and negative control (a group with no mouthwashes, even without the placebo). Lack of sample size predetermination based on a priori power calculations. The difference between the regime of Persica with that of Ortho-Kin and placebo (which had similar application protocols) disallowed perfectly effective blinding of the patients (hence, single-blind). Fixed orthodontic treatment might disrupt gingival health. Antimicrobial mouthwashes might reverse this. Both evaluated mouthwashes might have therapeutic effects. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  12. Efficacy of electrolysed oxidizing water in inactivating Vibrio parahaemolyticus on kitchen cutting boards and food contact surfaces.

    PubMed

    Chiu, T-H; Duan, J; Liu, C; Su, Y-C

    2006-12-01

    To determine the efficacy of electrolysed oxidizing (EO) water in inactivating Vibrio parahaemolyticus on kitchen cutting boards and food contact surfaces. Cutting boards (bamboo, wood and plastic) and food contact surfaces (stainless steel and glazed ceramic tile) were inoculated with V. parahaemolyticus. Viable cells of V. parahaemolyticus were detected on all cutting boards and food contact surfaces after 10 and 30 min, respectively, at room temperatures. Soaking inoculated food contact surfaces and cutting boards in distilled water for 1 and 3 min, respectively, resulted in various reductions of V. parahaemolyticus, but failed to remove the organism completely from surfaces. However, the treatment of EO water [pH 2.7, chlorine 40 ppm, oxidation-reduction potential 1151 mV] for 30, 45, and 60 s, completely inactivated V. parahaemolyticus on stainless steel, ceramic tile, and plastic cutting boards, respectively. EO water could be used as a disinfecting agent for inactivating V. parahaemolyticus on plastic and wood cutting boards and food contact surfaces. Rinsing the food contact surfaces with EO water or soaking cutting boards in EO water for up to 5 min could be a simple strategy to reduce cross-contamination of V. parahaemolyticus during food preparation.

  13. Biocompatible water softening system using cationic protein from moringa oleifera extract

    NASA Astrophysics Data System (ADS)

    Nisha, R. R.; Jegathambal, P.; Parameswari, K.; Kirupa, K.

    2017-10-01

    In developing countries like India, the deciding factors for the selection of the specific water purification system are the flow rate, cost of implementation and maintenance, availability of materials for fabrication or assembling, technical manpower, energy requirement and reliability. But most of them are energy and cost intensive which necessitate the development of cost-effective water purification system. In this study, the feasibility of development of an efficient and cost-effective water purifier using Moringa oleifera cationic protein coated sand column to treat drinking water is presented. Moringa oleifera seeds contain cationic antimicrobial protein which acts as biocoagulant in the removal of turbidity and also aids in water softening. The main disadvantage of using Moringa seeds in water purification is that the dissolved organic matter (DOM) which is left over in the water contributes to growth of any pathogens that come into contact with the stored water. To overcome this limitation, the Moringa oleifera cationic protein coated sand (MOCP c-sand) is prepared in which the flocculant and antimicrobial properties of the MOCP are maintained and the DOM to be rinsed away. The efficiency of MOCP c-sand in removing suspended particles and reducing total hardness (TH), chloride, total dissolved solids (TDS), electrical conductivity (EC) was also studied. Also, it is shown that the functionalized sand showed the same treatment efficiency even after being stored dry and in dehydrated condition for 3 months. This confirms MOCP c-sand's potential as a locally sustainable water treatment option for developing countries since other chemicals used in water purification are expensive.

  14. Management of dry mouth: assessment of oral symptoms after use of a polysaccharide-based oral rinse.

    PubMed

    Epstein, Joel B; Villines, Dana C; Singh, Mabi; Papas, Athena

    2017-01-01

    Salivary dysfunction is associated with a range of oral/dental issues, and management of oral symptoms may improve oral function and overall quality of life. The purpose of this pilot study was to evaluate oral symptoms and function in a xerostomic population after use of a proprietary topical for dry mouth, Moisyn (Synedgen Inc., Claremont, CA), which is a polysaccharide-based product. A pre- and post-test survey was completed by 57 patients with xerostomia. Patients rated their common oral symptoms, based on the Vanderbilt Head and Neck Symptom Survey, before and after 1-week use of Moisyn rinse and spray. Saliva production under resting and chewing stimulation was also assessed. Most patients reported relief from dry mouth symptoms and thick saliva (81.7% and 76.0%, respectively) for more than 30 minutes after product use. Statistically significant reductions were found in 15 of 33 oral symptoms. Symptom improvement ranged from 10.7% to 28.4% for thick saliva, 8.4% to 30.6% for pain, 5.5% to 30.4% for dry mouth, and 12% to 21.3% for taste/diet change. Whole unstimulated/resting saliva improved by 100%, and whole stimulated saliva improved by 23.8%. These findings suggest that the product has utility in symptom control in patients with xerostomia and may lead to an increase in saliva production. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Technical and economical evaluation of water recycling in the carwash industry with membrane processes.

    PubMed

    Boussu, K; Eelen, D; Vanassche, S; Vandecasteele, C; Van der Bruggen, B; Van Baelen, G; Colen, W; Vanassche, S

    2008-01-01

    In the carwash industry, water recycling is necessary to be in accordance with present and upcoming environmental laws. As this is not possible with traditional techniques, membrane processes (like ultrafiltration (UF) and nanofiltration (NF)) are technically and economically evaluated in this study. Concerning the technical part, there needs to be a compromise between a high permeate permeability on the one hand and a high permeate purity on the other hand. Depending on the use of the purified wastewater, ultrafiltration (to recycle wastewater in the main wash cycle) or nanofiltration (to recycle wastewater in the rinsing step) would be the optimal choice. Concerning the financial part, the implementation of membrane processes in the wastewater purification installation is economically feasible, especially when expensive tap water is used as pure water. These positive evaluations imply that membrane processes can be useful to recycle wastewater in the carwash industry, on condition that the right membrane type (with the least membrane fouling) and the right process format (e.g., hybrid process of UF and/or NF with a biological treatment) is selected. Copyright IWA Publishing 2008.

  16. Shear bond strength of two 2-step etch-and-rinse adhesives when bonding ceramic brackets to bovine enamel.

    PubMed

    Godard, Marion; Deuve, Benjamin; Lopez, Isabelle; Hippolyte, Marie-Pascale; Barthélemi, Stéphane

    2017-09-01

    The present study assessed a fracture analysis and compared the shear bond strength (SBS) of two 2-step etch-and-rinse (E&R) adhesives when bonding ceramic orthodontic brackets to bovine enamel. Thirty healthy bovine mandibular incisors were selected and were equally and randomly assigned to 2 experimental groups. Ceramic brackets (FLI Signature Clear ® , RMO) were bonded onto bovine enamel using an adhesive system. In group 1 (n=15), the conventional E&R adhesive (OrthoSolo ® +Enlight ® , Ormco) was used, and in group 2 (n=15), the new E&R adhesive limited to ceramic bracket bonding (FLI ceramic adhesive ® : FLI sealant resin ® +FLI adhesive paste ® , RMO) was used. In order to obtain appropriate enamel surfaces, the vestibular surfaces of mandibular bovine incisors were flat ground. After bonding, all the samples were stored in distilled water at room temperature for 21 days and subsequently tested for SBS, using the Instron ® universal testing machine. The Adhesive Remnant Index (ARI) scores were evaluated. Failure modes were assessed using optical microscopy at magnification ×40. A statistic data analysis was performed using the Mann-Whitney U-test (P<0.05). The test showed a significant difference (P=0.00155) between the two groups for the SBS values. Group 1 had significantly higher SBS values (9.79 to 20.83MPa) than group 2 (8.45 to 13.94MPa). Analysis of the ARI scores revealed that most of the failures occurred at the enamel/adhesive interface. A statistically significant difference was found for the ARI scores between the two groups (P=0.00996). Only two fractured brackets, which remained bonded onto the bovine enamel, were reported. Both occurred in group 1. When bonded to ceramic brackets, FLI ceramic adhesive ® (RMO) was demonstrated to be very predictable and safe for clinical application in enamel bonding, whereas the results obtained with the conventional adhesive system (OrthoSolo ® +Enlight ® , Ormco) were less reproducible and revealed

  17. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin.

    PubMed

    Gaddala, Naresh; Veeramachineni, Chandrasekhar; Tummala, Muralidhar

    2015-05-01

    Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but not statistically significant than smear clear.

  18. Effect of Peracetic Acid as A Final Rinse on Push Out Bond Strength of Root Canal Sealers to Root Dentin

    PubMed Central

    Gaddala, Naresh; Veeramachineni, Chandrasekhar

    2015-01-01

    Background Smear layer which was formed during the instrumentation of root canals hinders the penetration of root canal sealers to root dentin and affect the bond strength of root canal sealers to root dentin. Final irrigant such as demineralizing agents are used to remove the inorganic portion of the smear layer. In the present study, peracetic acid used as a final rinse, to effect the bond strength of root canal sealers to root dentin. Aim The purpose of the present study was to evaluate the efficacy of peracetic acid as a final irrigant on bond strength of root canal sealers to root dentin. Materials and Methods Sixty six freshly extracted human single rooted mandibular premolars were used for this study. After decoronation the samples were instrumented with Protaper upto F3 and irrigated with 5.25% NaOcl. The teeth were then divided into three groups based on final irrigant used: Group-1(control group) Canals were irrigated with distilled water. Group-2: Canals were irrigated with peracetic acid. Group-3: Canals were irrigated with smear clear. Each group was further divided into three subgroups (n=30) based on the sealer used to obturate the canals. Subgroup-1: kerr, Subgroup-2: Apexit plus, Subgroup-3: AH PLUS. Each sealer was mixed and coated to master cone and placed in the canal. The bonding between sealer and dentin surface was evaluated using push out bond strength by universal testing machine. The mean bond strength values of each group were statistically evaluated using Two-way ANOVA followed by Tukey post-hoc test. Results Significant difference was found among the bond strength of the sealers. But, there is no statistically significant difference between the groups irrigated with peracetic acid and smear clear compared to control group. AH Plus showed highest bond strength irrespective of the final irrigant used. Conclusion Peracetic acid when employed as final irrigant improved the bond strength of root canal sealers compared to control group but

  19. Lowering the environmental impact of high-kappa/ metal gate stack surface preparation processes

    NASA Astrophysics Data System (ADS)

    Zamani, Davoud

    ABSTRACT Hafnium based oxides and silicates are promising high-κ dielectrics to replace SiO2 as gate material for state-of-the-art semiconductor devices. However, integrating these new high-κ materials into the existing complementary metal-oxide semiconductor (CMOS) process remains a challenge. One particular area of concern is the use of large amounts of HF during wet etching of hafnium based oxides and silicates. The patterning of thin films of these materials is accomplished by wet etching in HF solutions. The use of HF allows dissolution of hafnium as an anionic fluoride complex. Etch selectivity with respect to SiO2 is achieved by appropriately diluting the solutions and using slightly elevated temperatures. From an ESH point of view, it would be beneficial to develop methods which would lower the use of HF. The first objective of this study is to find new chemistries and developments of new wet etch methods to reduce fluoride consumption during wet etching of hafnium based high-κ materials. Another related issue with major environmental impact is the usage of large amounts of rinsing water for removal of HF in post-etch cleaning step. Both of these require a better understanding of the HF interaction with the high-κ surface during the etching, cleaning, and rinsing processes. During the rinse, the cleaning chemical is removed from the wafers. Ensuring optimal resource usage and cycle time during the rinse requires a sound understanding and quantitative description of the transport effects that dominate the removal rate of the cleaning chemicals from the surfaces. Multiple processes, such as desorption and re-adsorption, diffusion, migration and convection, all factor into the removal rate of the cleaning chemical during the rinse. Any of these processes can be the removal rate limiting process, the bottleneck of the rinse. In fact, the process limiting the removal rate generally changes as the rinse progresses, offering the opportunity to save resources

  20. On-line monitoring of the photocatalytic degradation of 2,4-D and dicamba using a solid-phase extraction-multisyringe flow injection system.

    PubMed

    Chávez-Moreno, Carmín; Ferrer, Laura; Hinojosa-Reyes, Laura; Hernández-Ramírez, Aracely; Cerdà, Víctor; Guzmán-Mar, Jorge

    2013-11-15

    A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 μg L(-1) for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 μg L(-1) for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 μg L(-1) for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 μg L(-1) for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Efficacy of chlorhexidine, dexpanthenol, allantoin and chitosan gel in comparison with bicarbonate oral rinse in controlling post-interventional inflammation, pain and cicatrization in subjects undergoing dental surgery.

    PubMed

    Lopez-Lopez, Jose; Lope-Lopez, Jose; Jan-Pallí, Enric; lez-Navarro, Beatriz Gonzá; González-Navarro, Beatriz; Jané-Salas, Enric; Estrugo-Devesa, Albert; Milani, Massimo

    2015-12-01

    Reducing post-interventional inflammation and pain in odontostomatological surgery procedures, such as tooth extractions, implants or oral biopsies is a relevant clinical goal. Chlorhexidine oral rinse is commonly used with this aim. Recently a new product containing chlorhexidine, dexpanthenol, allantoin and chitosan (Bexident Post [BP]) in a gel formulation has been developed. We evaluated the efficacy of BP in controlling postsurgical inflammation and pain and in promoting cicatrization in subjects undergoing molar extractions. We conducted a prospective sequential cross-over, randomized controlled study in patients undergoing surgical removal of at least two impacted mandibular third molars (teeth numbers 38 and 48) (numbers 17 and 32 in the Universal Tooth Numbering System), in two separate sessions, to determine the effect of BP in comparison with bicarbonate (BC) oral rinse (one spoonful in 200 ml of water), both used three times daily. Each subject utilized both products in a randomized sequential manner after each tooth extraction. Primary outcomes of the study were post-procedure pain and inflammation. Secondary outcomes were analgesic pill rescue use (metamizole 1 cap every 8 hours if needed) and an assessor-blinded evaluation of cicatrization with a semi-quantitative scale (good, satisfactory and insufficient). Post-procedure pain was assessed 6 hours after tooth extraction and for seven consecutive days by means of a 10 cm visual analogue scale (VAS) (from 0: no pain to 10: extreme pain). The extent of inflammation was evaluated through metric measurements of facial perimeter using standardized anatomical reference points. A total of 47 patients (22 men and 25 women; mean age 34 years) were enrolled with a total of 94 molars extracted. Nineteen subjects applied BC as the first sequential treatment and 28 BP as the first. Before surgery no mean differences in the two treatments in inflammation measurements were observed. After surgery mean VAS pain

  2. Solar photocatalytic ozonation of a mixture of pharmaceutical compounds in water.

    PubMed

    Márquez, Gracia; Rodríguez, Eva M; Beltrán, Fernando J; Álvarez, Pedro M

    2014-10-01

    Aqueous solutions of mixtures of four pharmaceutical compounds (atenolol, hydrochlorothiazide, ofloxacin and trimethoprim) both in Milli-Q ultrapure water and in a secondary effluent from a municipal wastewater treatment plant have been treated at pH 7 by different oxidation methods, such as conventional ozonation, photolytic ozonation, TiO2 catalytic ozonation, TiO2 photocatalytic oxidation and TiO2 photocatalytic ozonation. Experiments were carried out using a solar compound parabolic concentrator. The performance results have been compared in terms of removal of emerging contaminants (ECs), generation rate of phenolic intermediates, organic matter mineralization, ecotoxicity removal and enhancement of biodegradability. Also, the consumption of ozone to achieve certain treatment goals (95% removal of ECs and 40% mineralization) is discussed. Results reveal that solar photocatalytic ozonation is a promising oxidation method as it led to the best results in terms of EC mineralization (∼85%), toxicity removal (∼90%) and efficient use of ozone (∼2mgO3mgEC(-1) to achieve complete EC removal and ∼18mgO3mgTOC(-1) to achieve 40% EC mineralization, respectively). Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Flow injection determination of aluminium by spectrofluorimetric detection after complexation with N-o-vanillidine-2-amino-p-cresol: the application to natural waters.

    PubMed

    Kara, Derya; Fisher, Andrew; Hill, Steve J

    2008-03-17

    An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 degrees C. An interference from fluoride ions was minimised by the addition of Be(2+). Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000microgL(-1) (r=0.999). The limit of detection (3sigma) for the determination of Al(III) was 0.057microgL(-1) and the precision for multiple determinations of 3ngmL(-1) Al(III) prepared in ultra-pure water was found to be 0.62% (n=10). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.

  4. Dependence of precipitation of trace elements on pH in standard water

    NASA Astrophysics Data System (ADS)

    Verma, Shivcharan; Mohanty, Biraja P.; Singh, K. P.; Behera, B. R.; Kumar, Ashok

    2018-04-01

    The present work aimed to study the dependence of precipitation of trace elements on the pH of solution. A standard solution was prepared by using ultrapure deionized water (18.2 MΩ/cm) as the solvent and 11 water-soluble salts having different elements as solutes. Five samples of different pH values (2 acidic, 2 basic, and 1 neutral) were prepared from this standard solution. Sodium-diethyldithiocarbamate was used as the chelating agent to precipitate the metal ions present in these samples of different pH values. The targets were prepared by collecting these precipitates on mixed cellulose esters filter of 0.4 μm pore size by vacuum filtration. Elemental analysis of these targets was performed by particle-induced X-ray emission (PIXE) using 2.7 MeV protons from the single Dee variable energy cyclotron at Panjab University, Chandigarh, India. PIXE data were analyzed using GUPIXWIN software. For most of the elements, except Hg with oxidation state +2, such as Co, Ni, Zn, Ba, and Cd, a general trend of enhancement in precipitation was observed with the increase in pH. However, for other elements such as V, As, Mo, Ag, and Bi, which have oxidation state other than +2, no definite pattern was observed. Precipitation of Ba and As using this method was negligible at all five pH values. From these results, it can be concluded that the precipitation and recovery of elements depend strongly on the pH of the water sample.

  5. Efficacy and safety of spinosad and permethrin creme rinses for pediculosis capitis (head lice).

    PubMed

    Stough, Dow; Shellabarger, Susan; Quiring, John; Gabrielsen, Alvin A

    2009-09-01

    Studies compared spinosad creme rinse and permethrin lice treatment under "actual-use" conditions for pediculosis capitis (head lice). Two phase-3, multicenter, randomized, evaluator/investigator-blinded studies compared 0.9% spinosad without nit-combing to 1% permethrin with combing (according to product instructions) in 1038 males and females aged > or =6 months. Spinosad-with-combing groups were included for descriptive, noninferential purposes only. Within 391 households, youngest members having > or =3 live lice were designated primary participants. All household members with lice received the same treatment. Participants administered product 1 to 2 times during the 21-day home-use period on the basis of complete lice eradication after a single use or the presence of lice requiring a second treatment. Scalp evaluations were performed at baseline, day 7, and day 14 (and day 21 for participants treated twice). The primary end point was the proportion of lice-free primary participants 14 days after last treatment. A total of 84.6% (study 1) and 86.7% (study 2) of spinosad-treated participants were lice free versus 44.9% and 42.9% permethrin-treated participants (P < .001). Most spinosad-treated participants required 1 application, whereas most permethrin-treated participants required 2 applications. Few adverse events were reported, but those occurring were mild to moderate, including eye irritation (permethrin), ocular hyperemia, and application-site erythema/irritation (both medications). No laboratory measure changed significantly. Spinosad, which did not require nit combing, was significantly more effective than permethrin in 2 studies reflecting actual-use conditions, and most spinosad-treated participants required only 1 application. Spinosad is a more convenient and effective treatment for pediculosis capitis.

  6. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and... in each cargo tank. (5) Volume of water used for water rinsing. (6) Trim conditions of the tank...

  7. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and... in each cargo tank. (5) Volume of water used for water rinsing. (6) Trim conditions of the tank...

  8. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and... in each cargo tank. (5) Volume of water used for water rinsing. (6) Trim conditions of the tank...

  9. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and... in each cargo tank. (5) Volume of water used for water rinsing. (6) Trim conditions of the tank...

  10. Relocation of net-acid-generating waste to improve post-mining water chemistry.

    PubMed

    Morin, K A; Hutt, N M

    2001-01-01

    Acidic drainage and metal leaching are long-term environmental liabilities that can persist for many decades to millennia. One technique to improve the water chemistry and ecology of post-mining landscapes is to relocate and submerge net-acid-generating mine materials in a lake or water-retaining impoundment. One example of a carefully executed relocation of waste rock took place at the Eskay Creek Mine in Canada. Pre-relocation studies included an empirical relationship that related (1) the amount of acidity retained by the waste rock during past oxidation to (2) the amount of lime needed in each truckload for neutralization of the acidity and for suppression of metal release. During relocation, thousands of rinse pH measurements indicated net acidity varied significantly over short distances within the waste rock and that acidic rock could not be reliably segregated from near-netural rock. After relocation, water from the watershed continued to be acidic for a few years, then returned to near-neutral pH and near-background concentrations of metals. The chemistry of the lake where the waste rock was submerged remains near background conditions. Therefore, with careful planning and implementation, the relocation and submergence of net-acid-generating materials can greatly improve post-mining water chemistry.

  11. The effect of polyvinylpyrrolidone-sodium hyaluronate gel (Gelclair) on oral microbial colonization and pain control compared with other rinsing solutions in patients with oral mucositis after allogeneic stem cells transplantation

    PubMed Central

    Vokurka, Samuel; Skardova, Jana; Hruskova, Renata; Kabatova-Maxova, Klara; Svoboda, Tomas; Bystricka, Eva; Steinerova, Katerina; Koza, Vladimir

    2011-01-01

    Summary Background Gelclair is an oral lubricating gel used in the management of oral mucositis (OM). We evaluated its efficacy, tolerance and impact on oral cavity microbial colonization in patients with OM after allogeneic hematopoietic stem cells transplantation. Material/Method Gelclair was administered in a group of 22 patients with active OM. A control group of 15 patients used other rinsing solutions (chlorhexidine, benzydamine, salvia). Tests with oral cavity swabs for microbiology analysis were performed once a week. Results The characteristics of OM in both groups were comparable, and rinsing solutions had satisfactory tolerability. There was no difference in the median improvement of oral intake and OM-related pain relief, which was assessed mostly as “slight effect”. In the Gelclair group, the effect duration was longer (median 3 [0–5] vs. 1 [0–3] hours, p=0.001). There was significant increase of Enterococcus faecalis and Candida sp. colonization of the oral cavity over the course of the hospitalization and significantly reduced incidence of such colonization in patients with OM in the Gelclair group: 1/22 (5%) vs. 6/15 (40%), p=0.01. In vitro tests showed inhibited growth of Enterococcus faecalis and Candida sp. colonies within the area of the Gelclair application. Conclusions Gelclair may be individually helpful in the management of OM and pain in patients after allogeneic stem cells transplantation. Its use did not lead to worsened oral bacterial and yeast colonization and probably even helped to protect mucosa from Enterococcus and Candida sp. Further studies based on larger cohorts are needed. PMID:21959611

  12. Kinetics of aqueous chlorination of some pharmaceuticals and their elimination from water matrices.

    PubMed

    Acero, Juan L; Benitez, F Javier; Real, Francisco J; Roldan, Gloria

    2010-07-01

    Apparent rate constants for the reactions of four selected pharmaceutical compounds (metoprolol, naproxen, amoxicillin, and phenacetin) with chlorine in ultra-pure (UP) water were determined as a function of the pH. It was found that amoxicillin (in the whole pH range 3-12), and naproxen (in the low pH range 2-4) presented high reaction rates, while naproxen (in the pH range 5-9), and phenacetin and metoprolol (in the pH range 2.5-12 for phenacetin, and 3-10 for metoprolol) followed intermediate and slow reaction rates. A mechanism is proposed for the chlorination reaction, which allowed the evaluation of the intrinsic rate constants for the elementary reactions of the ionized and un-ionized species of each selected pharmaceutical with chlorine. An excellent agreement is obtained between experimental and calculated rate constants by this mechanism.The elimination of these substances in several waters (a groundwater, a surface water from a public reservoir, and two effluents from municipal wastewater treatment plants) was also investigated at neutral pH. The efficiency of the chlorination process with respect to the pharmaceuticals elimination and the formation THMs was also established. It is generally observed that the increasing presence of organic and inorganic matter in the water matrices demand more oxidant agent (chlorine), and therefore, less chlorine is available for the oxidation of these compounds. Finally, half-life times and oxidant exposures (CT) required for the removal of 99% of the four pharmaceuticals are also evaluated. These parameters are useful for the establishment of safety chlorine doses in oxidation or disinfection stages of pharmaceuticals in treatment plants.

  13. Analysis of perfluoroalkyl substances in waters from Germany and Spain.

    PubMed

    Llorca, Marta; Farré, Marinella; Picó, Yolanda; Müller, Jutta; Knepper, Thomas P; Barceló, Damià

    2012-08-01

    Water has been identified as one of the main routes of human exposure to perfluoroalkyl substances (PFASs). This work assessed the presence of 21 PFASs along the whole water cycle using a new fast and cost effective analytical method based on an online sample enrichment followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The method was validated for different types of matrices (ultrapure water, tap water and treated wastewater). The quality parameters for the 21 selected compounds presented good limits of detection (LOD) and quantification (LOQ) ranging, in general, from 0.83-10 ng/L to 2.8-50 ng/L, respectively. The method was applied to assess the occurrence of PFASs in 148 water samples of different steps along the whole water cycle, including: mineral bottled water, tap water, river water and treated effluent wastewater, from Germany to Spain. In addition, in order to prove the good performance of the online analytical method, the analysis of PFASs was carried out in parallel using a method based on offline anionic solid phase extraction (SPE) followed by LC-MS/MS. Consistent results were obtained using both approaches. The more frequently found compounds were perfluoroalkyl acids, such as the perfluorobutanoic acid which was in the 54% of the tap water samples investigated with concentrations in the range between 2.4 and 27 ng/L, the perfluoroheptanoic acid (0.23-53 ng/L) and perfluorooctanoic acid (0.16-35 ng/L), and the sulphonate perfluorooctanesulfonate (0.04-258 ng/L) which was the second more frequent compound and also the compound found in with the higher concentration. It should be remarked that the 88% of the samples analyzed presented at least one of the compounds at quantifiable concentrations. In addition, PFASs including short chain compounds were proved to be prevalent in drinking water, and the 50% of the drinking water samples showed quantifiable concentrations of PFASs. It should be said that the great majority of

  14. 40 CFR 63.11507 - What are my standards and management practices?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... distilled/de-ionized water, water filtration, pre-cleaning of parts to be plated, and thorough rinsing of... emissions from the thermal spraying process and transports the emissions to a water curtain, fabric filter... and transports the emissions to a water curtain, fabric filter, cartridge, or HEPA filter, according...

  15. Oil-based compositions as saliva substitutes: A pilot study to investigate in-mouth retention.

    PubMed

    Hanning, Sara M; Medlicott, Natalie J

    2016-03-30

    This pilot study aimed to compare the in-mouth retention of an oil-based saliva substitute (emulsion, consisting of rice bran oil, soy lecithin and water) with water and a 1% w/v methylcellulose suspension (polymer) in healthy volunteers. Each formulation was tagged with 1 mmol/L lithium and participants (n=30) rinsed their mouth with one randomly assigned formulation (emulsion, polymer or water) for 30s, before expectorating into a cup. Concentration of lithium expectorated was measured and amount of each formulation remaining in the mouth was estimated. Patient acceptability was investigated using questionnaires, and Fourier-Transform Infrared spectroscopy (FTIR) was used to determine the presence of oil in expectorated samples. Immediately after rinsing, taste was rated lower in the emulsion group compared to the polymer or water groups (p>0.05), although variability was high. Mean retention was highest in the emulsion group, with a difference of 8.34 ± 2.71% (p=0.003) and 4.57 ± 2.71% (p=0.06) compared with the water and polymer groups, respectively. FTIR confirmed the presence of oil in all expectorated emulsion samples. The emulsion was not inferior to the polymer in terms of retention immediately after rinsing. The next step is to conduct larger clinical studies over longer time periods in participants with salivary hypofunction. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Optimization of the Determination Method for Dissolved Cyanobacterial Toxin BMAA in Natural Water.

    PubMed

    Yan, Boyin; Liu, Zhiquan; Huang, Rui; Xu, Yongpeng; Liu, Dongmei; Lin, Tsair-Fuh; Cui, Fuyi

    2017-10-17

    There is a serious dispute on the existence of β-N-methylamino-l-alanine (BMAA) in water, which is a neurotoxin that may cause amyotrophic lateral sclerosis/Parkinson's disease (ALS/PDC) and Alzheimer' disease. It is believed that a reliable and sensitive analytical method for the determination of BMAA is urgently required to resolve this dispute. In the present study, the solid phase extraction (SPE) procedure and the analytical method for dissolved BMAA in water were investigated and optimized. The results showed both derivatized and underivatized methods were qualified for the measurement of BMAA and its isomer in natural water, and the limit of detection and the precision of the two methods were comparable. Cartridge characteristics and SPE conditions could greatly affect the SPE performance, and the competition of natural organic matter is the primary factor causing the low recovery of BMAA, which was reduced from approximately 90% in pure water to 38.11% in natural water. The optimized SPE method for BMAA was a combination of rinsed SPE cartridges, controlled loading/elution rates and elution solution, evaporation at 55 °C, reconstitution of a solution mixture, and filtration by polyvinylidene fluoride membrane. This optimized method achieved > 88% recovery of BMAA in both algal solution and river water. The developed method can provide an efficient way to evaluate the actual concentration levels of BMAA in actual water environments and drinking water systems.

  17. The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation.

    PubMed

    Peitsch, T; Klocke, A; Kahl-Nieke, B; Prymak, O; Epple, M

    2007-09-01

    The influence of dynamic mechanical loading and of surface nitridation on the nickel release from superelastic nickel-titanium orthodontic wires was investigated under ultrapure conditions. Commercially available superelastic NiTi arch wires (size 0.018 x 0.025'') without surface modification (Neo Sentalloy) and with nitrogen ion implantation surface treatment (Neo Sentalloy Ionguard) were analyzed. Mechanical loading of wire segments with a force similar to the physiological situation was performed with a frequency of 5 Hz in ultrapure water and saline solution, respectively. The release of nickel was monitored by atomic absorption spectroscopy for up to 36 days. The mechanically loaded wires released significantly more nickel ( approximately 45 ng cm(-2) d(-1)) than did nonloaded wires (<1 ng cm(-2) d(-1)). There was no statistically significant effect of the testing solution (water or NaCl) or of the surface nitridation. The total amount of released nickel was small in all cases, but may nevertheless account for the occasional clinical observations of adverse reactions during application of NiTi-based orthodontic appliances. The surface nitridation did not constrain the release of nickel from NiTi under continuous mechanical stress.

  18. Approaching behavior of a pair of spherical bubbles in quiescent liquids

    NASA Astrophysics Data System (ADS)

    Sanada, Toshiyuki; Kusuno, Hiroaki

    2015-11-01

    Some unique motions related bubble-bubble interaction, such as equilibrium distance, wake induced lift force, have been proposed by theoretical analysis or numerical simulations. These motions are different from the solid spheres like DKT model (Drafting, Kissing and Tumbling). However, there is a lack of the experimental verification. In this study, we experimentally investigated the motion of a pair of bubbles initially positioned in-line configuration in ultrapure water or an aqueous surfactant solution. The bubble motion were observed by two high speed video cameras. The bubbles Reynolds number was ranged from 50 to 300 and bubbles hold the spherical shape in this range. In ultrapure water, initially the trailing bubble deviated from the vertical line on the leading bubble owing to the wake of the leading bubble. And then, the slight difference of the bubble radius changed the relative motion. When the trailing bubble slightly larger than the leading bubble, the trailing bubble approached to the leading bubble due to it's buoyancy difference. The bubbles attracted and collided only when the bubbles rising approximately side by side configuration. In addition, we will also discuss the motion of bubbles rising in an aqueous surfactant solution.

  19. METHOD OF CHEMICAL DECONTAMINATION OF STAINLESS STEEL NUCLEAR FACILITIES

    DOEpatents

    Pancer, G.P.; Zegger, J.L.

    1961-12-19

    A chemical method is given for removing activated corrosion products on the primary system surfaces of a pressurized water reactor. The corrosion product deposits are composed chiefly of magnetite (Fe/sub 3/O/sub 4/) with small amounts of nickel and chromium oxides. The corroded surfaces are first flushed with a caustic permanganate primary solution consisting of sodium hydroxide and potassium permanganate followed by a secondary rinse solution of ammonium citrate and citric acid containing the complexing agent Versene in small amounts. Demineralized water is used to clean out the primary and secondary solutions and a 60-minute drying period precedes the rinse solution. (AEC)

  20. Impact of orthophosphate addition on biofilm development in drinking water distribution systems.

    PubMed

    Gouider, Mbarka; Bouzid, Jalel; Sayadi, Sami; Montiel, Antoine

    2009-08-15

    The contamination of the water distribution network results from fixed bacteria multiplication (biofilm) on the water pipe walls, followed by their detachment and their transport in the circulating liquid. The presence of biofilms in distribution networks can result in numerous unwanted problems for the user such as microbial contamination of the distributed water and deterioration of the network (bio-corrosion). For old networks, lead-containing plumbings can be a serious cause of worry for the consumer owing to the release of lead ions in the circulating water. Among the solutions considered to reduce the presence of lead in drinking water, the addition of orthophosphates constitutes an interesting alternative. However, the added orthophosphate may cause--even at low doses--additional microbial growth. The main objective of this study was to evaluate the impact of the orthophosphate treatment on the biofilm development in the water supplied by the Joinville-le-Pont water treatment plant (Eau de Paris, France). For this purpose, a laboratory pilot plant was devised and connected to the considered water network. Two quantification methods for monitoring the biofilm formation were used: the enumeration on R2A agar and the determination of proteins. For the biofilm detachment operation, an optimization of the rinsing step was firstly conducted in order to distinguish between free and fixed biomass. The data obtained showed that there was a linear relation between both quantification methods. They also showed that, for the tested water, the bacterial densities were not affected by orthophosphate addition at a treatment rate of 1mg PO(4)(3-)/L.

  1. Emerging nitrogenous disinfection byproducts: Transformation of the antidiabetic drug metformin during chlorine disinfection of water.

    PubMed

    Armbruster, Dominic; Happel, Oliver; Scheurer, Marco; Harms, Klaus; Schmidt, Torsten C; Brauch, Heinz-Jürgen

    2015-08-01

    As an environmental contaminant of anthropogenic origin metformin is present in the high ng/L- up to the low μg/L-range in most surface waters. Residues of metformin may lead to the formation of disinfection by-products during chlorine disinfection, when these waters are used for drinking water production. Investigations on the underlying chemical processes occurring during treatment of metformin with sodium hypochlorite in aqueous medium led to the discovery of two hitherto unknown transformation products. Both substances were isolated and characterized by HPLC-DAD, GC-MS, HPLC-ESI-TOF, (1)H-NMR and single-crystal X-ray structure determination. The immediate major chlorination product is a cyclic dehydro-1,2,4-triazole-derivate of intense yellow color (Y; C4H6ClN5). It is a solid chlorimine of limited stability. Rapid formation was observed between 10 °C and 30 °C, as well as between pH 3 and pH 11, in both ultrapure and tap water, even at trace quantities of reactants (ng/L-range for metformin, mg/L-range for free chlorine). While Y is degraded within a few hours to days in the presence of light, elevated temperature, organic solvents and matrix constituents within tap water, a secondary degradation product was discovered, which is stable and colorless (C; C4H6ClN3). This chloroorganic nitrile has a low photolysis rate in ambient day light, while being resistant to heat and not readily degraded in the presence of organic solvents or in the tap water matrix. In addition, the formation of ammonia, dimethylamine and N,N-dimethylguanidine was verified by cation exchange chromatography. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Evaluation of on-line concentration coupled to liquid chromatography tandem mass spectrometry for the quantification of neonicotinoids and fipronil in surface water and tap water.

    PubMed

    Montiel-León, Juan Manuel; Duy, Sung Vo; Munoz, Gabriel; Amyot, Marc; Sauvé, Sébastien

    2018-04-01

    A study was initiated to investigate a fast and reliable method for the determination of selected systemic insecticides in water matrixes and to evaluate potential sources of bias in their analysis. Acetamiprid, clothianidin, desnitro-imidacloprid, dinotefuran, fipronil, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam were amenable to analysis via on-line sample enrichment hyphenated to ultra-high-performance liquid chromatography tandem mass spectrometry. The selection of on-line solid-phase extraction parameters was dictated by a multicriterion desirability approach. A 2-mL on-line injection volume with a 1500 μL min -1 loading flow rate met the objectives sought in terms of chromatographic requirements, extraction efficiency, sensitivity, and precision. A total analysis time of 8 min per sample was obtained with method limits of detection in the range of 0.1-5 ng L -1 for the scope of targeted analytes. Automation at the sample concentration step yielded intraday and interday precisions in the range of 1-23 and 2-26%, respectively. Factors that could affect the whole method accuracy were further evaluated in matrix-specific experiments. The impact of the initial filtration step on analyte recovery was evaluated in ultra-pure water, tap water, and surface water. Out of the nine membranes tested, glass fiber filters and polyester filters appeared as the most appropriate materials. Sample storage stability was also investigated across the three matrix types; the targeted analytes displayed suitable stability during 28 days at either 4 °C or - 20 °C, with little deviations (± 10%) with respect to the initial T 0 concentration. Method applicability was demonstrated in a range of tap water and surface water samples from the province of Québec, Canada. Results from the present survey indicated a predominance of thiamethoxam (< 0.5-10 and 3-61 ng L -1 in tap water and river water, respectively), clothianidin (< 0.5-6 and 2-88 ng L -1 in

  3. Cleaning and activation of beryllium-copper electron multiplier dynodes.

    NASA Technical Reports Server (NTRS)

    Pongratz, M. B.

    1972-01-01

    Description of a cleaning and activation procedure followed in preparing beryllium-copper dynodes for electron multipliers used in sounding-rocket experiments to detect auroral electrons. The initial degreasing step involved a 5-min bath in trichloroethylene in an ultrasonic cleaner. This was followed by an ultrasonic rinse in methanol and by a two-step acid pickling treatment to remove the oxides. Additional rinsing in water and methanol was followed by activation in a stainless-steel RF induction oven.

  4. The Muon System of the Daya Bay Reactor Antineutrino Experiment

    DOE PAGES

    An, F. P.; Hackenburg, R. W.; Brown, R. E.; ...

    2014-10-05

    The Daya Bay experiment consists of functionally identical antineutrino detectors immersed in pools of ultrapure water in three well-separated underground experimental halls near two nuclear reactor complexes. These pools serve both as shields against natural, low-energy radiation, and as water Cherenkov detectors that efficiently detect cosmic muons using arrays of photomultiplier tubes. Each pool is covered by a plane of resistive plate chambers as an additional means of detecting muons. Design, construction, operation, and performance of these muon detectors are described. (auth)

  5. Oxidation of Tris (2-chloroethyl) phosphate in aqueous solution by UV-activated peroxymonosulfate: Kinetics, water matrix effects, degradation products and reaction pathways.

    PubMed

    Xu, Xinxin; Chen, Jing; Qu, Ruijuan; Wang, Zunyao

    2017-10-01

    The feasibility of UV-activated peroxymonosulfate (PMS) technology for the degradation of Tris (2-chloroethyl) phosphate (TCEP) in an aqueous solution was investigated in this study. The conditions of [PMS] 0 : [TCEP] 0  = 20:1, T = 25 ± 2 °C and pH = 5.5 ± 0.5 cause a 94.6% removal of TCEP (1 mg L -1 ) after 30 min of Hg lamp irradiation. The effects of operating parameters (the oxidant doses, pH and presence of typical cations (Fe 3+ , Cu 2+ , Ni 2+ , NH 4 + ), anions (Cl - , HCO 3 - , NO 3 - , HPO 4 2- ) and humic acid (HA)) were evaluated. It was found that an increase of the PMS dose and the presence of Fe 3+ could accelerate the reaction, while the anions and HA inhibited the reaction. Meanwhile, TCEP removal in various water matrices was compared, and the order for TCEP removal was as follows: ultrapure water > tap water > synthetic water > secondary clarifier effluent > Jiuxiang river water. Twenty-two oxidation products were identified using an electrospray time-of-flight mass spectrometer, and the degradation pathways mainly involved radicals' addition and CO bond cleavage. Furthermore, ECOSAR analysis revealed that the intermediate products during the TCEP oxidation process were generally not harmful to three typical aquatic species. Hence, UV/PMS can be used as an efficient technology to treat TCEP-containing water and wastewaters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Effect of fluoride on growth and acid production by Streptococcus mutans in dental plaque.

    PubMed Central

    van der Hoeven, J S; Franken, H C

    1984-01-01

    The aim of this study was to measure the effect of fluoride on the production of organic acids by Streptococcus mutans in dental plaque. The effect was studied in a simplified model of dental plaque with gnotobiotic rats monoinfected with S. mutans Ny341. Adaptation of S. mutans to fluoride was induced by feeding one group of the rats on fluoride-containing diet and drinking water. No difference was found in the accumulation of S. mutans on the teeth between the fluoride-adapted and the control groups. However, there was a significant difference in the amount of lactic acid in metabolically resting plaque between the groups, lactic acid being lower in the fluoride-adapted plaque. At 5 min after a rinse containing 10% sucrose, a high level of lactic acid was found in plaque from animals not exposed to fluoride. Rinses containing 4 or 20 mM fluoride before the sucrose rinse significantly inhibited the lactic acid production in the control group. In the plaque from rats on fluoridated diet and drinking water the sucrose-induced production of lactic acid was not inhibited by a 4 mM fluoride rinse. Moreover, the production of lactic acid in the fluoride-adapted plaque was prolonged. The results indicate that due to fluoride adaptation the inhibition of acid production is unlikely to be important for the caries-preventive action of fluoride. PMID:6746094

  7. Development of classification models to detect Salmonella Enteritidis and Salmonella Typhimurium found in poultry carcass rinses by visible-near infrared hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Seo, Young Wook; Yoon, Seung Chul; Park, Bosoon; Hinton, Arthur; Windham, William R.; Lawrence, Kurt C.

    2013-05-01

    Salmonella is a major cause of foodborne disease outbreaks resulting from the consumption of contaminated food products in the United States. This paper reports the development of a hyperspectral imaging technique for detecting and differentiating two of the most common Salmonella serotypes, Salmonella Enteritidis (SE) and Salmonella Typhimurium (ST), from background microflora that are often found in poultry carcass rinse. Presumptive positive screening of colonies with a traditional direct plating method is a labor intensive and time consuming task. Thus, this paper is concerned with the detection of differences in spectral characteristics among the pure SE, ST, and background microflora grown on brilliant green sulfa (BGS) and xylose lysine tergitol 4 (XLT4) agar media with a spread plating technique. Visible near-infrared hyperspectral imaging, providing the spectral and spatial information unique to each microorganism, was utilized to differentiate SE and ST from the background microflora. A total of 10 classification models, including five machine learning algorithms, each without and with principal component analysis (PCA), were validated and compared to find the best model in classification accuracy. The five machine learning (classification) algorithms used in this study were Mahalanobis distance (MD), k-nearest neighbor (kNN), linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and support vector machine (SVM). The average classification accuracy of all 10 models on a calibration (or training) set of the pure cultures on BGS agar plates was 98% (Kappa coefficient = 0.95) in determining the presence of SE and/or ST although it was difficult to differentiate between SE and ST. The average classification accuracy of all 10 models on a training set for ST detection on XLT4 agar was over 99% (Kappa coefficient = 0.99) although SE colonies on XLT4 agar were difficult to differentiate from background microflora. The average classification

  8. The prevention of plaque re-growth by toothpastes and solutions containing block copolymers with and without polypeptide.

    PubMed

    Claydon, N C; Addy, M; Newcombe, R; Moran, J

    2005-06-01

    Chemicals which have a direct effect at inhibiting or reducing bacterial adherence to tooth surfaces may subsequently inhibit plaque growth and reduce gingival inflammation. This study investigated whether two anti-adherent systems could inhibit plaque re-growth in the mouth when rinsed as a solution or as a toothpaste slurry. A total of 21 subjects took part in a partially blind, seven cell cross-over study which compared the effects on plaque re-growth of a binary system containing block copolymers, a ternary system containing block copolymers and polypeptide, both used as toothpaste slurry rinses, their corresponding solution rinses, a conventional fluoride toothpaste rinse, a positive control chlorhexidine rinse and a negative water control. Following a dental prophylaxis subjects then rinsed with 10 ml of one of the test products for 1 min. twice a day over a 4-day period. Throughout each trial period the subjects were not permitted to use any other forms of oral hygiene. On the fifth day (96 h), the volunteers returned to the clinic, and plaque was assessed by (1) plaque index and (2) plaque area following disclosing with a food dye. The test phase of the trial was repeated for each agent and was followed by a 10-day "washout" period. Essentially neither of the anti-adherent systems inhibited plaque re-growth, whether administered in a toothpaste slurry or solution compared with the controls. If anything, neither of the test pastes were as effective as the marketed commercial paste (p<0.001). As expected plaque recorded following use of the chlorhexidine rinse was significantly less than that seen with any of the other rinses (p<0.001). Using this 4-day plaque re-growth model, the findings of this study failed to show any benefit in using the anti-adherent systems, either in a rinse or toothpaste, with the aim of inhibiting or reducing plaque formation.

  9. Standard on microbiological management of fluids for hemodialysis and related therapies by the Japanese Society for Dialysis Therapy 2008.

    PubMed

    Kawanishi, Hideki; Akiba, Takashi; Masakane, Ikuto; Tomo, Tadashi; Mineshima, Michio; Kawasaki, Tadayuki; Hirakata, Hideki; Akizawa, Tadao

    2009-04-01

    The Committee of Scientific Academy of the Japanese Society for Dialysis Therapy (JSDT) proposes a new standard on microbiological management of fluids for hemodialysis and related therapies. This standard is within the scope of the International Organization for Standardization (ISO), which is currently under revision. This standard is to be applied to the central dialysis fluid delivery systems (CDDS), which are widely used in Japan. In this standard, microbiological qualities for dialysis water and dialysis fluids are clearly defined by endotoxin level and bacterial count. The qualities of dialysis fluids were classified into three levels: standard, ultrapure, and online prepared substitution fluid. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently used in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility should validate the microbiological qualities of online prepared substitution fluid.

  10. The effect of a supersaturated calcium phosphate mouth rinse on the development of oral mucositis in head and neck cancer patients treated with (chemo)radiation: a single-center, randomized, prospective study of a calcium phosphate mouth rinse + standard of care versus standard of care.

    PubMed

    Lambrecht, Maarten; Mercier, Carole; Geussens, Yasmyne; Nuyts, Sandra

    2013-10-01

    Mucosal damage is an important and debilitating side effect when treating head and neck cancer patients with (chemo-)radiation. The aim of this randomized clinical trial was to investigate whether the addition of a neutral, supersaturated, calcium phosphate (CP) mouth rinse benefits the severity and duration of acute mucositis in head and neck cancer patients treated with (chemo)radiation. A total of 60 patients with malignant neoplasms of the head and neck receiving (chemo)radiation were included in this study. Fifty-eight patients were randomized into two treatment arms: a control group receiving standard of care (n = 31) and a study group receiving standard of care + daily CP mouth rinses (n = 27) starting on the first day of (chemo-)radiation. Oral mucositis and dysphagia were assessed twice a week using the National Cancer Institute common toxicity criteria scale version 3, oral pain was scored with a visual analogue scale. No significant difference in grade III mucositis (59 vs. 71 %; p = 0.25) and dysphagia (33 vs. 42 %, p = 0.39) was observed between the study group compared to the control group. Also no significant difference in time until development of peak mucositis (28.6 vs. 28.7 days; p = 0.48), duration of peak mucositis (22.7 vs. 24.6 days; p = 0.31), recuperation of peak dysphagia (20.5 vs 24.2 days; p = 0.13) and occurrence of severe pain (56 vs. 52 %, p = 0.5). In this randomized study, the addition of CP mouth rinse to standard of care did not improve the frequency, duration or severity of the most common acute toxicities during and early after (chemo)radiation. There is currently no evidence supporting its standard use in daily practice.

  11. Assessment of the UV/Cl2 advanced oxidation process for the degradation of the emerging contaminants amitriptyline hydrochloride, methyl salicylate and 2-phenoxyethanol in water systems.

    PubMed

    Javier Benitez, F; Real, Francisco J; Acero, Juan L; Casas, Francisco

    2017-10-01

    Three emerging contaminants (amitriptyline hydrochloride (AH), methyl salicylate (MS) and 2-phenoxyethanol (PE)) frequently found in wastewaters were selected to be individually degraded in ultra-pure water by the advanced oxidation process (AOP) constituted by the combination of UV radiation and chlorine. The influence of pH, initial chlorine concentration and nature of the contaminants was firstly explored. The trend for the reactivity of the selected compounds was deduced: AH > MS > PE. A later kinetic study was carried out focused on the evaluation of the first-order rate constants and the determination of the partial contribution to the global reaction of the direct photochemical pathway and the radical pathway. In a second stage, the simultaneous oxidation of mixtures of the selected contaminants in several types of water was also performed by the same combination UV/Cl 2 . The efficiency of this combined system UV/Cl 2 was compared to other oxidants such as the UV/[Formula: see text] and UV/H 2 O 2 AOPs, and the influence of the operating variables was discussed. Results confirmed that the UV/Cl 2 system provides higher elimination efficiencies among the AOPs tested. The presence of dissolved organic matter and bicarbonate ions in the water matrix caused a decrease in the treatment efficiency.

  12. Cleaning process for EUV optical substrates

    DOEpatents

    Weber, Frank J.; Spiller, Eberhard A.

    1999-01-01

    A cleaning process for surfaces with very demanding cleanliness requirements, such as extreme-ultraviolet (EUV) optical substrates. Proper cleaning of optical substrates prior to applying reflective coatings thereon is very critical in the fabrication of the reflective optics used in EUV lithographic systems, for example. The cleaning process involves ultrasonic cleaning in acetone, methanol, and a pH neutral soap, such as FL-70, followed by rinsing in de-ionized water and drying with dry filtered nitrogen in conjunction with a spin-rinse.

  13. Ultra high performance liquid chromatography tandem mass spectrometry for rapid analysis of trace organic contaminants in water

    PubMed Central

    2013-01-01

    Background The widespread utilization of organic compounds in modern society and their dispersion through wastewater have resulted in extensive contamination of source and drinking waters. The vast majority of these compounds are not regulated in wastewater outfalls or in drinking water while trace amounts of certain compounds can impact aquatic wildlife. Hence it is prudent to monitor these contaminants in water sources until sufficient toxicological data relevant to humans becomes available. A method was developed for the analysis of 36 trace organic contaminants (TOrCs) including pharmaceuticals, pesticides, steroid hormones (androgens, progestins, and glucocorticoids), personal care products and polyfluorinated compounds (PFCs) using a single solid phase extraction (SPE) technique with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was applied to a variety of water matrices to demonstrate method performance and reliability. Results UHPLC-MS/MS in both positive and negative electrospray ionization (ESI) modes was employed to achieve optimum sensitivity while reducing sample analysis time (<20 min) compared with previously published methods. The detection limits for most compounds was lower than 1.0 picogram on the column while reporting limits in water ranged from 0.1 to 15 ng/L based on the extraction of a 1 L sample and concentration to 1 mL. Recoveries in ultrapure water for most compounds were between 90-110%, while recoveries in surface water and wastewater were in the range of 39-121% and 38-141% respectively. The analytical method was successfully applied to analyze samples across several different water matrices including wastewater, groundwater, surface water and drinking water at different stages of the treatment. Among several compounds detected in wastewater, sucralose and TCPP showed the highest concentrations. Conclusion The proposed method is sensitive, rapid and robust; hence it can

  14. Elution Is a Critical Step for Recovering Human Adenovirus 40 from Tap Water and Surface Water by Cross-Flow Ultrafiltration

    PubMed Central

    Shi, Hang; Xagoraraki, Irene; Bruening, Merlin L.

    2016-01-01

    of HAdV 40 was evaluated, with postelution recoveries from ultrapure water (99%), tap water (∼91%), and high-carbon-content surface water (∼84%) being demonstrated. These results are significant because of the very low adenovirus recoveries that have been reported, to date, for other methods. The recovery data were interpreted in terms of specific interactions, and the eluent composition was designed accordingly to maximize HAdV 40 recovery. PMID:27287319

  15. Paper pulp-based adsorbents for the removal of pharmaceuticals from wastewater: A novel approach towards diversification.

    PubMed

    Oliveira, Gonçalo; Calisto, Vânia; Santos, Sérgio M; Otero, Marta; Esteves, Valdemar I

    2018-08-01

    In this work, two pulps, bleached (BP) and raw pulp (RP), derived from the paper production process, were used as precursors of non-activated and activated carbons (ACs). In the case of non-ACs, the production involved either pyrolysis or pyrolysis followed by acid washing. For ACs production, the pulps were impregnated with K 2 CO 3 or H 3 PO 4 , and then pyrolysed and acid washed. After production, the materials were physically and chemically characterized. Then, batch adsorption tests on the removal of two pharmaceuticals (the anti-epileptic carbamazepine (CBZ) and the antibiotic sulfamethoxazole (SMX)) from ultra-pure water and from Waste Water Treatment Plant (WWTP) effluents were performed. In ultra-pure water, non-ACs were not able to adsorb CBZ or SMX while ACs showed good adsorption capacities. In WWTP effluents, although ACs satisfactorily adsorbed CBZ and SMX, they showed lower adsorption capacities for the latter. Tests with WWTP effluents revealed that the best adsorption capacities were achieved by carbons produced from BP and activated with H 3 PO 4 : 92±19mgg -1 for CBZ and 13.0±0.6mgg -1 for SMX. These results indicate the potential of paper pulps as precursors for ACs that can be applied in wastewater treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. The effects of feedstock pre-treatment and pyrolysis temperature on the production of biochar from the green seaweed Ulva.

    PubMed

    Roberts, David A; de Nys, Rocky

    2016-03-15

    Green seaweeds from the genus Ulva are a promising feedstock for the production of biochar for carbon (C) sequestration and soil amelioration. Ulva can be cultivated in waste water from land-based aquaculture and Ulva blooms ("green tides") strand millions of tons of biomass on coastal areas of Europe and China each year. The conversion of Ulva into biochar could recycle C and nutrients from eutrophic water into agricultural production. We produce biochar from Ulva ohnoi, cultivated in waste water from an aquaculture facility, and characterize its suitability for C sequestration and soil amelioration through bio-chemical analyses and plant growth experiments. Two biomass pre-treatments (fresh water rinsing to reduce salt, and pelletisation to increase density) were crossed with four pyrolysis temperatures (300-750 °C). Biomass rinsing decreased the ash and increased the C content of the resulting biochar. However, biochar produced from un-rinsed biomass had a higher proportion of fixed C and a higher yield. C sequestration decreased with increasing pyrolysis temperatures due to the combination of lower yield and lower total C content of biochar produced at high temperatures. Biochar produced from un-rinsed biomass at 300 °C had the greatest gravimetric C sequestration (110-120 g stable C kg(-1) seaweed). Biochar produced from un-pelletised Ulva enhanced plant growth three-fold in low fertility soils when the temperature of pyrolysis was less than 450 °C. The reduced effectiveness of the high-temperature biochars (>450 °C) was due to a lower N and higher salt content. Soil ameliorated with biochar produced from pelletised biomass had suppressed plant germination and growth. The most effective biochar for C sequestration and soil amelioration was produced from un-rinsed and un-pelletised Ulva at 300 °C. The green tide that occurs annually along the Shandong coastline in China generates sufficient biomass (200,000 tons dry weight) to ameliorate 12,500

  17. Effect of enamel etching time on roughness and bond strength.

    PubMed

    Barkmeier, Wayne W; Erickson, Robert L; Kimmes, Nicole S; Latta, Mark A; Wilwerding, Terry M

    2009-01-01

    The current study examined the effect of different enamel conditioning times on surface roughness and bond strength using an etch-and-rinse system and four self-etch adhesives. Surface roughness (Ra) and composite to enamel shear bond strengths (SBS) were determined following the treatment of flat ground human enamel (4000 grit) with five adhesive systems: (1) Adper Single Bond Plus (SBP), (2) Adper Prompt L-Pop (PLP), (3) Clearfil SE Bond (CSE), (4) Clearfil S3 Bond (CS3) and (5) Xeno IV (X4), using recommended treatment times and an extended treatment time of 60 seconds (n = 10/group). Control groups were also included for Ra (4000 grit surface) and SBS (no enamel treatment and Adper Scotchbond Multi-Purpose Adhesive). For surface roughness measurements, the phosphoric acid conditioner of the SBP etch-and-rinse system was rinsed from the surface with an air-water spray, and the other four self-etch adhesive agents were removed with alternating rinses of water and acetone. A Proscan 2000 non-contact profilometer was used to determine Ra values. Composite (Z100) to enamel bond strengths (24 hours) were determined using Ultradent fixtures and they were debonded with a crosshead speed of 1 mm/minute. The data were analyzed with ANOVA and Fisher's LSD post-hoc test. The etch-and- rinse system (SBP) produced the highest Ra (microm) and SBS (MPa) using both the recommended treatment time (0.352 +/- 0.028 microm and 40.5 +/- 6.1 MPa) and the extended treatment time (0.733 +/- 0.122 microm and 44.2 +/- 8.2 MPa). The Ra and SBS of the etch-and-rinse system were significantly greater (p < 0.05) than all the self-etch systems and controls. Increasing the treatment time with phosphoric acid (SBP) and PLP produced greater surface roughness (p < 0.05) but did not result in significantly higher bond strengths (p > 0.05).

  18. Managing Chemotherapy Side Effects: Mouth and Throat Changes

    MedlinePlus

    ... fluoride in it. ● ● Rinse your mouth with the baking soda, salt, and water mix in the box ... together: ● ● 1 cup warm water, ● ● 1 / 4 teaspoon baking soda, and ● ● 1 / 8 teaspoon salt. Take small ...

  19. Chemical milling solution reveals stress corrosion cracks in titanium alloy

    NASA Technical Reports Server (NTRS)

    Braski, D. N.

    1967-01-01

    Solution of hydrogen flouride, hydrogen peroxide, and water reveals hot salt stress corrosion cracks in various titanium alloys. After the surface is rinsed in water, dried, and swabbed with the solution, it can be observed by the naked eye or at low magnification.

  20. A 36-month evaluation of self-etch and etch-and-rinse adhesives in noncarious cervical lesions.

    PubMed

    Loguercio, Alessandro Dourado; Bittencourt, Dax Dalton; Baratieri, Luiz Narciso; Reis, Alessandra

    2007-04-01

    There are two bonding strategies for composite restorations: the etch-and-rinse (ER) approach and the self-etch (SE) approach. Few clinical trials have evaluated the SE approach in Class V restorations for a 36-month period. The authors conducted a study to evaluate whether the SE system can provide retention rates and marginal discoloration similar to that of the ER system. Twenty-five patients, each having at least two pairs of equivalent noncarious cervical lesions under occlusion, were enrolled in this study. Two calibrated operators placed 78 restorations, one-half for ER and one-half for SE. Two independent examiners evaluated the restorations at baseline and after six-, 12-, 18- and 36-month periods according to the slightly modified U.S. Public Health Service criteria. Statistical analysis between materials in each period was conducted using a Fisher exact test (alpha = .05), and the performance of the materials at baseline in comparison with each period was evaluated by a McNemar test (alpha = .05). Five SE restorations and one ER restoration were lost after 36 months. After 36 months, 10 SE and five ER restorations were rated Bravo in marginal adaptation (P > .05). Fourteen SE and five ER restorations were rated Bravo in marginal discoloration (P < .05). Although a significantly increased marginal discoloration was observed with SE, both adhesives showed retention rates in noncarious cervical lesions that were not statistically different after 36 months. The ER and SE adhesive systems can be used with confidence; however, SE adhesive showed a faster and more progressive enamel marginal degradation.