Sample records for ultraslim upper endoscope

  1. Direct peroral cholangioscopy using an ultraslim upper endoscope for biliary lesions.

    PubMed

    Omuta, Shigefumi; Maetani, Iruru; Ukita, Takeo; Nambu, Tomoko; Gon, Katsushige; Shigoka, Hiroaki; Saigusa, Yoshinori; Saito, Michihiro

    2014-02-01

    The development of direct peroral cholangioscopy (DPOC) using an ultraslim endoscope simplifies biliary cannulation. The conventional techniques are cumbersome to perform and require advanced skills. The recent introduction of the guidewires and balloons has improved the therapeutic outcomes. Here we describe an effective and easier method for performing DPOC using an ultraslim upper endoscope. Indications for DPOC were the presence of stones on follow-up of patients who had previously undergone complete sphincteroplasty, including endoscopic sphincterotomy or endoscopic papillary large balloon dilatation. Fifteen patients underwent DPOC. An ultraslim endoscope was inserted perorally and was advanced into the major papilla. The ampulla of Vater was visualized by retroflexing the endoscope in the distal second portion of the duodenum, and then DPOC was performed using a wire-guided cannulation technique with an anchored intraductal balloon catheter. One patient failed in the treatment due to looping of the endoscope in the fornix of the stomach. Fourteen (93.3%) were successfully treated with our modified DPOC technique. Only one patient (6.7%) experienced an adverse event (pancreatitis) who responded well to conservative management. Residual stones of the common bile duct were completely removed in 3 patients. The modified method of DPOC is simple, safe and easy to access the bile duct.

  2. Direct peroral cholangioscopy using an ultraslim upper endoscope for management of residual stones after mechanical lithotripsy for retained common bile duct stones.

    PubMed

    Lee, Y N; Moon, J H; Choi, H J; Min, S K; Kim, H I; Lee, T H; Cho, Y D; Park, S-H; Kim, S-J

    2012-09-01

    The incidence of residual stones after mechanical lithotripsy for retained common bile duct (CBD) stones is relatively high. Peroral cholangioscopy using a mother-baby system may be useful for confirming complete extraction of stones, but has several limitations regarding routine use. We evaluated the role of direct peroral cholangioscopy (DPOC) using an ultraslim upper endoscope for the evaluation and removal of residual CBD stones after mechanical lithotripsy. From August 2006 to November 2010, 48 patients who had undergone mechanical lithotripsy for retained CBD stones with no evidence of filling defects in balloon cholangiography were recruited. The bile duct was inspected by DPOC after balloon cholangiography. Detected residual CBD stones were directly retrieved with a basket or balloon catheter under DPOC. The incidence of residual stones detected by DPOC, and the success rate of residual stone retrieval under DPOC were investigated. DPOC was successfully performed in 46 of the 48 patients (95.8%). Of these, 13 patients (28.3%) had residual CBD stones (mean number 1.4, range 1-3; mean diameter 4.5 mm, range 2.3-9.6). The residual stones were removed directly under DPOC in 11 of these patients (84.6%). There were no complications associated with DPOC or stone removal. DPOC using an ultraslim upper endoscope is a useful endoscopic procedure for the evaluation and extraction of residual stones after mechanical lithotripsy for retained CBD stones. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon.

    PubMed

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-08-14

    To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation.

  4. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon

    PubMed Central

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-01-01

    AIM: To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). METHODS: Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. RESULTS: Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. CONCLUSION: Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation. PMID:22912549

  5. Endoscopic Management of Upper Urinary Tract Urothelial Carcinoma.

    PubMed

    Samson, Patrick; Smith, Arthur D; Hoenig, David; Okeke, Zeph

    2018-05-01

    Endoscopic management of upper tract urothelial carcinoma has become more popular over the last few decades as there has been an impetus for renal preservation in these patients. While radical nephroureterectomy has been the gold standard in treatment of this disease, ureteroscopic and percutaneous management has become a viable option for select patients. The literature on endoscopic management of upper urinary tract tumors was explored. Different management methods are discussed, both from published literature and experience of the authors of this chapter. We review the indications, details of the procedure, and troubleshooting methods in the endoscopic management of upper tract urothelial carcinoma. Imperative indications as well as controversial indications are discussed. The role and efficacy of adjuvant intrarenal topical agents are examined as well as the protocol for administering these agents. Follow-up protocols are also reviewed. In select patients, endoscopic management with ureteroscopy and/or percutaneous resection of upper tract urothelial tumors is appropriate and can preserve renal function while obtaining comparable oncologic control compared with radical surgery.

  6. Design and evaluation of an ultra-slim objective for in-vivo deep optical biopsy

    PubMed Central

    Landau, Sara M.; Liang, Chen; Kester, Robert T.; Tkaczyk, Tomasz S.; Descour, Michael R.

    2010-01-01

    An estimated 1.6 million breast biopsies are performed in the US each year. In order to provide real-time, in-vivo imaging with sub-cellular resolution for optical biopsies, we have designed an ultra-slim objective to fit inside the 1-mm-diameter hypodermic needles currently used for breast biopsies to image tissue stained by the fluorescent probe proflavine. To ensure high-quality imaging performance, experimental tests were performed to characterize fiber bundle’s light-coupling efficiency and simulations were performed to evaluate the impact of candidate lens materials’ autofluorescence. A prototype of NA = 0.4, 250-µm field of view, ultra-slim objective optics was built and tested, yielding diffraction-limited performance and estimated resolution of 0.9 µm. When used in conjunction with a commercial coherent fiber bundle to relay the image formed by the objective, the measured resolution was 2.5 µm. PMID:20389489

  7. Endoscopic low coherence interferometry in upper airways

    NASA Astrophysics Data System (ADS)

    Delacrétaz, Yves; Boss, Daniel; Lang, Florian; Depeursinge, Christian

    2009-07-01

    We introduce Endoscopic Low Coherence Interferometry to obtain topology of upper airways through commonly used rigid endoscopes. Quantitative dimensioning of upper airways pathologies is crucial to provide maximum health recovery chances, for example in order to choose the correct stent to treat endoluminal obstructing pathologies. Our device is fully compatible with procedures used in day-to-day examinations and can potentially be brought to bedside. Besides this, the approach described here can be almost straightforwardly adapted to other endoscopy-related field of interest, such as gastroscopy and arthroscopy. The principle of the method is first exposed, then filtering procedure used to extract the depth information is described. Finally, demonstration of the method ability to operate on biological samples is assessed through measurements on ex-vivo pork bronchi.

  8. Upper Gastrointestinal Involvement in Crohn Disease: Histopathologic and Endoscopic Findings.

    PubMed

    Diaz, Liege; Hernandez-Oquet, Rafael Enrique; Deshpande, Amar R; Moshiree, Baharak

    2015-11-01

    Studies describing the prevalence of upper gastrointestinal (GI) Crohn disease (CD) and its histopathologic changes have been inconsistent as a result of different definitions used for upper GI involvement, diverse populations, and varying indications for endoscopy. We reviewed the literature describing endoscopic findings and histologic lesions in gastric and duodenal mucosa of patients with established CD. PubMed, EMBASE, and the Cochrane Library were searched for gastroduodenal biopsy findings in patients with CD from 1970 to 2014. We included all retrospective and prospective studies in adults. We calculated the prevalence of the most common endoscopic and histopathological findings among patients with overall CD and upper GI CD. Of the 385 articles identified, 20 eligible studies were included. A total of 2511 patients had CD and 815 had upper GI CD. In the CD group, the most common histopathological finding was nonspecific gastric inflammation in 32% of patients, followed by gastric granuloma in 7.9%. Focal gastritis was prevalent in 30.9% of patients. In the upper GI CD group, gastric inflammation was present in 84% of patients, followed by duodenal inflammation in 28.2% and gastric granuloma in 23.2%. The most common gastric endoscopic finding in patients with CD was erythema in 5.9%, followed by erosions in 3.7%. Duodenal endoscopic findings included ulcers and erythema in 5.3% and 3.0% of patients, respectively. We found a prevalence of 34% for CD involving the upper GI tract across these 20 studies. Routine upper endoscopy with biopsies of the upper GI tract in the diagnostic workup of patients with CD can correctly classify the distribution and extent of the disease.

  9. Ultra-slim flexible glass for roll-to-roll electronic device fabrication

    NASA Astrophysics Data System (ADS)

    Garner, Sean; Glaesemann, Scott; Li, Xinghua

    2014-08-01

    As displays and electronics evolve to become lighter, thinner, and more flexible, the choice of substrate continues to be critical to their overall optimization. The substrate directly affects improvements in the designs, materials, fabrication processes, and performance of advanced electronics. With their inherent benefits such as surface quality, optical transmission, hermeticity, and thermal and dimensional stability, glass substrates enable high-quality and long-life devices. As substrate thicknesses are reduced below 200 μm, ultra-slim flexible glass continues to provide these inherent benefits to high-performance flexible electronics such as displays, touch sensors, photovoltaics, and lighting. In addition, the reduction in glass thickness also allows for new device designs and high-throughput, continuous manufacturing enabled by R2R processes. This paper provides an overview of ultra-slim flexible glass substrates and how they enable flexible electronic device optimization. Specific focus is put on flexible glass' mechanical reliability. For this, a combination of substrate design and process optimizations has been demonstrated that enables R2R device fabrication on flexible glass. Demonstrations of R2R flexible glass processes such as vacuum deposition, photolithography, laser patterning, screen printing, slot die coating, and lamination have been made. Compatibility with these key process steps has resulted in the first demonstration of a fully functional flexible glass device fabricated completely using R2R processes.

  10. Prevalence of incidental pancreatic cyst on upper endoscopic ultrasound

    PubMed Central

    Martínez, Belén; Martínez, Juan F.; Aparicio, José R.

    2018-01-01

    Background: This study aimed to determine the prevalence of incidental pancreatic cysts in patients undergoing upper endoscopic ultrasound without a known pancreatic abnormality. Methods: This prospective study was conducted in two hospitals in Spain and enrolled consecutive patients referred for upper endoscopic ultrasound for a condition unrelated to the pancreas. Patients with a previous pancreatic anomaly, history of acute or chronic pancreatitis, evidence of acute pancreatitis, previous upper gastrointestinal surgery, or chronic abdominal pain suggestive of pancreatic origin were excluded. Univariate logistic regression was performed to evaluate individual covariates and the incidental pancreatic cyst risk. Results: A total of 298 patients were included, of whom 64 had pancreatic cysts (21.5%; 16.9-26.6%). The mean size of the cysts was 6.3±3.7 (range 3-25) mm. Six cysts (2%) were >10 mm and 16 (5.4%) were compatible with branch duct intraductal papillary mucinous neoplasm. The pancreatic cyst prevalence was similar in the two hospitals and increased significantly with age. Conclusion: The prevalence of incidental pancreatic cysts during endoscopic ultrasound was very high in our study population. PMID:29333072

  11. Predictors for the need for endoscopic therapy in patients with presumed acute upper gastrointestinal bleeding.

    PubMed

    Kim, Su Sun; Kim, Kyung Up; Kim, Sung Jun; Seo, Seung In; Kim, Hyoung Su; Jang, Myoung Kuk; Kim, Hak Yang; Shin, Woon Geon

    2017-12-15

    Selecting patients with an urgent need for endoscopic hemostasis is difficult based only on simple parameters of presumed acute upper gastrointestinal bleeding. This study assessed easily applicable factors to predict cases in need of urgent endoscopic hemostasis due to acute upper gastrointestinal bleeding. The consecutively included patients were divided into the endoscopic hemostasis and nonendoscopic hemostasis groups. We reviewed the enrolled patients' medical records and analyzed various variables and parameters for acute upper gastrointestinal bleeding outcomes such as demographic factors, comorbidities, symptoms, signs, laboratory findings, rebleeding rate, and mortality to evaluate simple predictive factors for endoscopic treatment. A total of 613 patients were analyzed, including 329 patients in the endoscopic hemostasis and 284 patients in the non-endoscopic hemostasis groups. In the multivariate analysis, a bloody nasogastric lavage (adjusted odds ratio [AOR], 6.786; 95% confidence interval [CI], 3.990 to 11.543; p < 0.0001) and a hemoglobin level less than 8.6 g/dL (AOR, 1.768; 95% CI, 1.028 to 3.039; p = 0.039) were independent predictors for endoscopic hemostasis. Significant differences in the morbidity rates of endoscopic hemostasis were detected between the group with no predictive factors and the group with one or more predictive factors (OR, 2.677; 95% CI, 1.920 to 3.733; p < 0.0001). A bloody nasogastric lavage and hemoglobin < 8.6 g/dL were independent predictors of endoscopic hemostasis in patients with acute upper gastrointestinal bleeding.

  12. ENDOSCOPIC FINDINGS OF UPPER GASTROINTESTINAL BLEEDING IN PATIENTS WITH LIVER CIRROSIS.

    PubMed

    Hadayat, Rania; Jehangiri, Attique-ur-Rehman; Gul, Rahid; Khan, Adil Naseer; Said, Khalid; Gandapur, Asadullah

    2015-01-01

    Acute upper gastrointestinal (GI) bleeding is a common medical emergency. A common risk factor of upper GI bleeding is cirrhosis of liver, which can lead to variceal haemorrhage. 30-40% of cirrhotic patients who bleed may have non-variceal upper GI bleeding and it is frequently caused by peptic ulcers, portal gastropathy, Mallory-Weiss tear, and gastroduodenal erosions. The objective of this study was to determine the frequency of upper gastrointestinal endoscopic findings among patients presenting with upper gastrointestinal bleeding with liver cirrhosis. This descriptive cross-sectional study was carried out in Gastroenterology & Hepatology Department of Ayub Teaching Hospital, Abbottabad from February 2012 to June 2013. 252 patients diagnosed with cirrhosis, presenting with upper GI bleed, age 50 years of either gender, and were included in the study. Non-probability consecutive sampling was used, Endoscopy was performed on each patient and the findings documented. The mean age was 57.84 +/- 6.29 years. There were 158 (62.7%) males and 94 (37.3%) females. The most common endoscopic finding was oesophageal varices (92.9%, n=234) followed by portal hypertensive gastropathy (38.9%, n=98) with almost equal distribution among males and females. Gastric varices were found in 33.3% of patients (n=84). Among other non-variceal lesions, peptic ulcer disease was seen in 26 patients (10.3%) while gastric erosions were found in 8 patients (3.2%). In patients with acute upper GI bleeding and liver cirrhosis, the most common endoscopic finding is oesophageal varices, with a substantially higher value in our part of the country, apart from other non-variceal causes.

  13. Successful Endoscopic Hemostasis Is a Protective Factor for Rebleeding and Mortality in Patients with Nonvariceal Upper Gastrointestinal Bleeding.

    PubMed

    Han, Yong Jae; Cha, Jae Myung; Park, Jae Hyun; Jeon, Jung Won; Shin, Hyun Phil; Joo, Kwang Ro; Lee, Joung Il

    2016-07-01

    Rebleeding and mortality rates remain high in patients with nonvariceal upper gastrointestinal bleeding. To identify clinical and endoscopic risk factors for rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding. This study was performed in patients with nonvariceal upper gastrointestinal bleeding who underwent upper endoscopic procedures between July 2006 and February 2013. Clinical and endoscopic characteristics were compared among patients with and without rebleeding and mortality. Logistic regression analysis was performed to determine independent risk factors for rebleeding and mortality. After excluding 64 patients, data for 689 patients with nonvariceal upper gastrointestinal bleeding were analyzed. Peptic ulcer (62.6 %) was by far the most common source of bleeding. Endoscopic intervention was performed within 24 h in 99.0 % of patients, and successful endoscopic hemostasis was possible in 80.7 % of patients. The 30-day rebleeding rate was 13.1 % (n = 93). Unsuccessful endoscopic hemostasis was found to be the only independent risk factor for rebleeding (odds ratio 79.6; 95 % confidence interval 37.8-167.6; p = 0.000). The overall 30-day mortality rate was 3.2 % (n = 23). Unsuccessful endoscopic hemostasis (odds ratio 4.9; 95 % confidence interval 1.7-13.9; p = 0.003) was also associated with increased 30-day mortality in patients with nonvariceal upper gastrointestinal bleeding. Successful endoscopic hemostasis is an independent protective factor for both rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding.

  14. Transcatheter arterial embolization for endoscopically unmanageable non-variceal upper gastrointestinal bleeding.

    PubMed

    Lee, Han Hee; Park, Jae Myung; Chun, Ho Jong; Oh, Jung Suk; Ahn, Hyo Jun; Choi, Myung-Gyu

    2015-07-01

    Transcatheter arterial embolization (TAE) is a therapeutic option for endoscopically unmanageable upper gastrointestinal (GI) bleeding. We aimed to assess the efficacy and clinical outcomes of TAE for acute non-variceal upper GI bleeding and to identify predictors of recurrent bleeding within 30 days. Visceral angiography was performed in 66 patients (42 men, 24 women; mean age, 60.3 ± 12.7 years) who experienced acute non-variceal upper GI bleeding that failed to be controlled by endoscopy during a 7-year period. Clinical information was reviewed retrospectively. Outcomes included technical success rates, complications, and 30-day rebleeding and mortality rates. TAE was feasible in 59 patients. The technical success rate was 98%. Rebleeding within 30 days was observed in 47% after an initial TAE and was managed with re-embolization in 8, by endoscopic intervention in 5, by surgery in 2, and by conservative care in 12 patients. The 30-day overall mortality rate was 42.4%. In the case of initial endoscopic hemostasis failure (n = 34), 31 patients underwent angiographic embolization, which was successful in 30 patients (96.8%). Rebleeding occurred in 15 patients (50%), mainly because of malignancy. Two factors were independent predictors of rebleeding within 30 days by multivariate analysis: coagulopathy (odds ratio [OR] = 4.37; 95% confidence interval [CI]: 1.25-15.29; p = 0.021) and embolization in ≥2 territories (OR = 4.93; 95% CI: 1.43-17.04; p = 0.012). Catheterization-related complications included hepatic artery dissection and splenic embolization. TAE controlled acute non-variceal upper GI bleeding effectively. TAE may be considered when endoscopic therapy is unavailable or unsuccessful. Correction of coagulopathy before TAE is recommended.

  15. Endoscopic vacuum therapy for various defects of the upper gastrointestinal tract.

    PubMed

    Kuehn, Florian; Loske, Gunnar; Schiffmann, Leif; Gock, Michael; Klar, Ernst

    2017-09-01

    Postoperative, iatrogenic or spontaneous upper gastrointestinal defects result in significant morbidity and mortality of the patients. In the last few years, endoscopic vacuum therapy (EVT) has been recognized as a new promising method for repairing upper gastrointestinal defects of different etiology. However, probably due to insufficient data and no commercially available system for EVT of the upper gastrointestinal tract, until the end of 2014, covering of esophageal defects with self-expanding metal stents (SEMS) were still the mainstay of endoscopic therapy. The aim of this article is to review the data available about EVT for various upper gastrointestinal defects. A selective literature search was conducted in Medline and PubMed (2007-2016), taking into account all the published case series and case reports reporting on the use of EVT in the management of upper gastrointestinal defects. EVT works through intracorporal application of negative pressure at the defect zone with an electronic controlled vacuum device along a polyurethane sponge drainage. This results in closure of the esophageal defect and internal drainage of the septic focus, simultaneously. Compared to stenting, EVT enables regular viewing of wound conditions with control of the septic focus and adjustment of therapy. Moreover, endoscopical negative pressure is applicable in all esophageal regions (cricopharygeal, tubular, gastroesophageal junction) and in anastomotic anatomic variants. EVT can be used solely as a definite treatment or as a complimentary therapy combined with operative revision. In total, there are published data of more than 200 patients with upper gastrointestinal defects treated with EVT, showing succes rates from 70-100%. The available data indicate that EVT is feasible, safe and effective with good short-term and long-term clinical outcomes in the damage control of upper GI-tract leaks. Still, a prospective multi-center study has to be conducted to proof the definite

  16. Guidelines for endoscopic management of non-variceal upper gastrointestinal bleeding.

    PubMed

    Fujishiro, Mitsuhiro; Iguchi, Mikitaka; Kakushima, Naomi; Kato, Motohiko; Sakata, Yasuhisa; Hoteya, Shu; Kataoka, Mikinori; Shimaoka, Shunji; Yahagi, Naohisa; Fujimoto, Kazuma

    2016-05-01

    Japan Gastroenterological Endoscopy Society (JGES) has compiled a set of guidelines for endoscopic management of non-variceal upper gastrointestinal bleeding using evidence-based methods. The major cause of non-variceal upper gastrointestinal bleeding is peptic gastroduodenal ulcer bleeding. As a result, these guidelines mainly focus on peptic gastroduodenal ulcer bleeding, although bleeding from other causes is also overviewed. From the epidemiological aspect, in recent years in Japan, bleeding from drug-related ulcers has become predominant in comparison with bleeding from Helicobacter pylori (HP)-related ulcers, owing to an increase in the aging population and coverage of HP eradication therapy by national health insurance. As for treatment, endoscopic hemostasis, in which there are a variety of methods, is considered to be the first-line treatment for bleeding from almost all causes. It is very important to precisely evaluate the severity of the patient's condition and stabilize the patient's vital signs with intensive care for successful endoscopic hemostasis. Additionally, use of antisecretory agents is recommended to prevent rebleeding after endoscopic hemostasis, especially for gastroduodenal ulcer bleeding. Eighteen statements with evidence and recommendation levels have been made by the JGES committee of these guidelines according to evidence obtained from clinical research studies. However, some of the statements that are supported by a low level of evidence must be confirmed by further clinical research. © 2016 Japan Gastroenterological Endoscopy Society.

  17. Endoscopic Treatment of Upper Tract Urothelial Carcinoma.

    PubMed

    Verges, Daniel P; Lallas, Costas D; Hubosky, Scott G; Bagley, Demetrius H

    2017-04-01

    This study aims to make the reader be aware of recent trends regarding the endoscopic management of upper tract urothelial carcinoma (UTUC) via review of the urologic literature over the past 5 years. Given the rare incidence of this disease, and the lack of level 1 evidence, systematic reviews and meta-analyses were also evaluated. Studies of importance are also considered and outlined in the annotated reference section. The PubMed database was queried using the following medical subject headings (MeSH terms): "carcinoma, transitional cell," "ureter," "ureteral neoplasms," "kidney pelvis," "endoscopy," "laser therapy," "ureteroscopy," "urologic surgical procedures," and "ureteroscopes." MeSH terms were linked together in varying combinations and limited to human studies in English. Given the relatively rare nature of upper tract urothelial carcinoma (UTUC), level 1 evidence regarding the efficacy of endoscopic treatment does not exist, even after 30+ years of experience. Rather, the literature available mostly is in the form of single institutional retrospective series consisting of relatively small numbers of patients with short to intermediate follow-up. Only within the last 3 years have published series with larger numbers of patients and mean follow-up over 5 years been made available. Even with these more robust experiences, comparisons among series are difficult given variable treatment and follow-up approaches. Most endoscopically managed UTUC will locally recur, especially with longer follow-up. Renal preservation rate is high, however, approaching 80% with follow-up well over 3 years. Patients with high-grade disease often fare poorly regardless of treatment modality. As such, endoscopic management for high-grade urothelial carcinoma should only be used in exceptional circumstances (i.e., in those patients medically unfit for NU or those with solitary kidneys wishing to avoid the morbidity of dialysis). No level 1 evidence exists for the routine use

  18. Upper non-variceal gastrointestinal bleeding - review the effectiveness of endoscopic hemostasis methods

    PubMed Central

    Szura, Mirosław; Pasternak, Artur

    2015-01-01

    Upper non-variceal gastrointestinal bleeding is a condition that requires immediate medical intervention and has a high associated mortality rate (exceeding 10%). The vast majority of upper gastrointestinal bleeding cases are due to peptic ulcers. Helicobacter pylori infection, non-steroidal anti-inflammatory drugs and aspirin are the main risk factors for peptic ulcer disease. Endoscopic therapy has generally been recommended as the first-line treatment for upper gastrointestinal bleeding as it has been shown to reduce recurrent bleeding, the need for surgery and mortality. Early endoscopy (within 24 h of hospital admission) has a greater impact than delayed endoscopy on the length of hospital stay and requirement for blood transfusion. This paper aims to review and compare the efficacy of the types of endoscopic hemostasis most commonly used to control non-variceal gastrointestinal bleeding by pooling data from the literature. PMID:26421105

  19. Rescue endoscopic bleeding control for nonvariceal upper gastrointestinal hemorrhage using clipping and detachable snaring.

    PubMed

    Lee, J H; Kim, B K; Seol, D C; Byun, S J; Park, K H; Sung, I K; Park, H S; Shim, C S

    2013-06-01

    Nonvariceal upper gastrointestinal (UGI) bleeding recurs after appropriate endoscopic therapy in 10 % - 15 % of cases. The mortality rate can be as high as 25 % when bleeding recurs, but there is no consensus about the best modality for endoscopic re-treatment. The aim of this study was to evaluate clipping and detachable snaring (CDS) for rescue endoscopic control of nonvariceal UGI hemorrhage. We report a case series of seven patients from a Korean tertiary center who underwent endoscopic hemostasis using the combined method of detachable snares with hemoclips. The success rate of endoscopic hemostasis with CDS was 86 %: six of the seven patients who had experienced primary endoscopic treatment failure or recurrent bleeding after endoscopic hemostasis were treated successfully. In conclusion, rescue endoscopic bleeding control by means of CDS is an option for controlling nonvariceal UGI bleeding when no other method of endoscopic treatment for recurrent bleeding and primary hemostatic failure is possible. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Perioperative patient radiation exposure in the endoscopic removal of upper urinary tract calculi.

    PubMed

    Jamal, Joseph E; Armenakas, Noel A; Sosa, R Ernest; Fracchia, John A

    2011-11-01

    The efficacy of computed tomography (CT) in detailing upper urinary tract calculi is well established. There is no established acceptable annual recommended limit for medical exposure, yet the global accepted upper limit for occupational radiation exposure is <50 millisieverts (mSv) in any one year. We sought to appreciate the CT and fluoroscopic radiation exposure to our patients undergoing endoscopic removal of upper tract calculi during the periprocedure period. All patients undergoing upper urinary endoscopic stone removal between 2005 and 2009 were identified. To calculate the cumulative radiation exposure, we included all ionizing radiation imaging performed during a periprocedure period, which we defined as ≤90 days pre- and post-therapeutic procedure. A total of 233 upper urinary tract therapeutic patient stone procedures were identified; 127 patients underwent ureteroscopy (URS) and 106 patients underwent percutaneous nephrolithotomy (PCNL). A mean 1.58 CTs were performed per patient. Ninety (38.6%) patients underwent ≥2 CTs in the periprocedure period, with an average number in this group of 2.49 CT/patient, resulting in approximately 49.8 mSv of CT radiation exposure. Patients who were undergoing URS were significantly more likely to have multiple CTs (P=0.003) than those undergoing PCNL. Median fluoroscopic procedure exposures were 43.3 mGy for patients who were undergoing PCNL and 27.6 mGy for those patients undergoing URS. CT radiation exposure in the periprocedure period for patients who were undergoing endoscopic upper tract stone removal is considerable. Added to this is the procedure-related fluoroscopic radiation exposure. Urologic surgeons should be aware of the cumulative amount of ionizing radiation received by their patients from multiple sources.

  1. Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure.

    PubMed

    Harima, Hirofumi; Hamabe, Kouichi; Hisano, Fusako; Matsuzaki, Yuko; Itoh, Tadahiko; Sanuki, Kazutoshi; Sakaida, Isao

    2018-05-23

    An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

  2. Endoscopic resection of upper neck masses via retroauricular approach is feasible with excellent cosmetic outcomes.

    PubMed

    Lee, Hyoung Shin; Lee, Dongwon; Koo, Yong Cheol; Shin, Hyang Ae; Koh, Yoon Woo; Choi, Eun Chang

    2013-03-01

    In this study, the authors introduce and evaluate the feasibility of endoscopic resection using the retroauricular approach for various benign lesions of the upper neck. A retrospective comparative analysis was performed on the clinical outcomes of patients who underwent surgery for upper neck masses as endoscopic resection using the retroauricular approach or conventional transcervical resection at the authors' center from January 2010 through August 2011. The primary outcome was the cosmetic satisfaction of the patients in each group. In addition, the feasibility of the procedure was evaluated by comparing the operation time; hospital stay; amount and duration of drainage; complications such as marginal mandibular nerve, lingual, or hypoglossal nerve palsy; paresthesia of the ear lobe; and wound problems such as hematoma and skin necrosis. Statistical analysis was performed by independent-samples t test and the Fisher exact test, and a P value less than .05 was considered statistically significant. Thirty-six patients underwent endoscopic resection (endo group; 15 men, 21 women; mean age, 38.8 ± 15.0 years) and 40 patients underwent conventional transcervical resection (conventional group; 18 men, 22 women; mean age, 45.1 ± 14.1 years). The operating time in the endo group was longer than in the conventional group (P = .003). No significant difference was observed in the overall perioperative complications between the 2 groups. Cosmetic satisfaction evaluated with a graded scale showed much better results in the endo group (P < .001). Endoscopic resection using the retroauricular approach is feasible for various benign upper neck masses when conducted by an experienced endoscopic surgeon, with excellent cosmetic results. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Endoscopic findings in upper gastrointestinal bleeding patients at Lacor hospital, northern Uganda.

    PubMed

    Alema, O N; Martin, D O; Okello, T R

    2012-12-01

    Upper gastrointestinal bleeding (UGIB) is a common emergency medical condition that may require hospitalization and resuscitation, and results in high patient morbidity. Upper gastrointestinal endoscopy is the preferred investigative procedure for UGIB because of its accuracy, low rate of complication, and its potential for therapeutic interventions. To determine the endoscopic findings in patients presenting with UGIB and its frequency among these patients according to gender and age in Lacor hospital, northern Uganda. The study was carried out at Lacor hospital, located at northern part of Uganda. The record of 224 patients who underwent endoscopy for upper gastrointestinal bleeding over a period of 5 years between January 2006 and December 2010 were retrospectively analyzed. A total of 224 patients had endoscopy for UGIB which consisted of 113 (50.4%) males and 111 (49.6%) females, and the mean age was 42 years ± SD 15.88. The commonest cause of UGIB was esophagealvarices consisting of 40.6%, followed by esophagitis (14.7%), gastritis (12.6%) and peptic ulcer disease (duodenal and gastric ulcers) was 6.2%. The malignant conditions (gastric and esophageal cancers) contributed to 2.6%. Other less frequent causes of UGIB were hiatus hernia (1.8), duodenitis (0.9%), others-gastric polyp (0.4%). Normal endoscopic finding was 16.1% in patients who had UGIB. Esophageal varices are the commonest cause of upper gastrointestinal bleeding in this environment as compared to the west which is mainly peptic ulcer disease.

  4. Results after endoscopic treatment of postoperative upper gastrointestinal fistulas and leaks using combined Vicryl plug and fibrin glue.

    PubMed

    Truong, S; Böhm, G; Klinge, U; Stumpf, M; Schumpelick, V

    2004-07-01

    The incidence of clinically relevant anastomotic leaks after upper gastrointestinal surgery is approximately 4% to 20%, and the associated mortality is up to 80%. Depending on the clinical presentation, the treatment options include surgery, conservative treatment with or without external drainage or endoscopic treatment. This report presents nine cases of anastomotic leaks or fistulae after surgery for upper gastrointestinal cancers that were treated by insertion of a Vicryl plug and sealing with fibrin glue. Under sedation, all nine patients underwent endoscopic lavage of the cavity at the site of anastomotic leakage. The entrance to the cavity then was filled with Vicryl mesh and sealed off with fibrin glue. After the procedure, the patients underwent endoscopy and a water-soluble contrast study for assessment of the result. Seven of the nine patients had complete healing of the anastomotic leak or fistula after one to two endoscopic treatments. In one case, the treatment failed immediately because of a large and direct tracheoesophageal fistula. Another patient experienced recurrent intrathoracic abscesses after initial technical success. Postoperative upper gastrointestinal fistulas or anastomotic leaks can be managed successfully with little morbidity by means of endoscopic insertion of Vicryl mesh with fibrin glue, thereby avoiding repetitive major surgery and its associated risks.

  5. Cooperative laparoscopic endoscopic and hybrid laparoscopic surgery for upper gastrointestinal tumors: Current status

    PubMed Central

    Ntourakis, Dimitrios; Mavrogenis, Georgios

    2015-01-01

    AIM: To investigate the cooperative laparoscopic and endoscopic techniques used for the resection of upper gastrointestinal tumors. METHODS: A systematic research of the literature was performed in PubMed for English and French language articles about laparoscopic and endoscopic cooperative, combined, hybrid and rendezvous techniques. Only original studies using these techniques for the resection of early gastric cancer, benign tumors and gastrointestinal stromal tumors of the stomach and the duodenum were included. By excluding case series of less than 10 patients, 25 studies were identified. The study design, number of cases, tumor pathology size and location, the operative technique name, the endoscopy team and surgical team role, operative time, type of closure of visceral wall defect, blood loss, complications and length of hospital stay of these studies were evaluated. Additionally all cooperative techniques found were classified and are presented in a systematic approach. RESULTS: The studies identified were case series and retrospective cohort studies. A total of 706 patients were operated on with a cooperative technique. The tumors resected were only gastrointestinal stromal tumors (GIST) in 4 studies, GIST and various benign submucosal tumors in 22 studies, early gastric cancer (pT1a and pT1b) in 6 studies and early duodenal cancer in 1 study. There was important heterogeneity between the studies. The operative techniques identified were: laparoscopic assisted endoscopic resection, endoscopic assisted wedge resection, endoscopic assisted transgastric and intragastric surgery, laparoscopic endoscopic cooperative surgery (LECS), laparoscopic assisted endoscopic full thickness resection (LAEFR), clean non exposure technique and non-exposed endoscopic wall-inversion surgery (NEWS). Each technique is illustrated with the roles of the endoscopic and laparoscopic teams; the indications, characteristics and short term results are described. CONCLUSION: Along with

  6. Endoscopic management of foreign bodies in the upper gastrointestinal tract: An analysis of 846 cases in China

    PubMed Central

    Yuan, Fangfang; Tang, Xiaowei; Gong, Wei; Su, Lei; Zhang, Yali

    2018-01-01

    Foreign body ingestion is a relatively common occurrence, which may lead to morbidity and mortality. The aim of the present study was to report the experience of management of upper gastrointestinal foreign bodies by endoscopy in a large center. All patients who presented at the Department of Gastroenterology at Nanfang Hospital (Guangzhou, China) with complaints regarding upper gastrointestinal (GI) foreign body ingestion from December 1987 to December 2013. Hospital medical charts and endoscopic records were examined to evaluate etiology, treatment, and outcomes for these patients. A total of 846 patients were enrolled in the present study, from which foreign bodies were detected in 737 (87.1%) patients via X-ray or endoscopy. The objects most frequently ingested were bones (n=395, 53.6%). The detected foreign bodies were predominantly located in the cervical esophagus (n=325, 44.1%). Endoscopic foreign body extraction was successful in 92.5% of cases, whereas surgery was required in 6 patients. The most frequently used endoscopic accessory devices were retrieval forceps (n=480, 65.1%). The complication rate was 6.9%, including mucosal laceration (n=10) and others, all of which were managed conservatively. Associated GI diseases were reported in 74 (10.0%) patients, including postesophagectomy (n=34) and others. In conclusion, the endoscopic procedure was safe and effective for the removal of foreign bodies from the upper gastrointestinal tract, with a high success rate and low complication rate. PMID:29434711

  7. A study of clinical and endoscopic profile of acute upper, gastrointestinal bleeding.

    PubMed

    Dewan, K R; Patowary, B S; Bhattarai, S

    2014-01-01

    Acute Upper Gastrointestinal Bleeding is a common medical emergency with a hospital mortality of approximately 10 percent. Higher mortality rate is associated with rebleeding. Rockall scoring system identifies patients at higher risk of rebleed and mortality. To study the clinical and endoscopic profile of acute upper gastrointestinal bleed to know the etiology, clinical presentation, severity of bleeding and outcome. This is a prospective, descriptive hospital based study conducted in Gastroenterology unit of College of Medical Sciences and Teaching Hospital, Bharatpur, Nepal from January 2012 to January 2013. It included 120 patients at random presenting with manifestations of upper gastrointestinal bleed. Their clinical and endoscopic profiles were studied. Rockall scoring system was used to assess their prognosis. Males were predominant (75%). Age ranged from 14 to 88 years, mean being 48.76+17.19. At presentation 86 patients (71.7%) had both hematemesis and malena, 24 patients (20%) had only malena and 10 patients (8.3%) had only hematemesis. Shock was detected in 21.7%, severe anemia and high blood urea were found in 34.2% and 38.3% respectively. Upper Gastrointestinal Bleeding endoscopy revealed esophageal varices (47.5%), peptic ulcer disease (33.3%), erosive mucosal disease (11.6%), Mallory Weiss tear (4.1%) and malignancy (3.3%). Median hospital stay was 7.28+3.18 days. Comorbidities were present in 43.3%. Eighty six patients (71.7%) had Rockall score < 5 and 34 (28.3%) had >6. Five patients (4.2%) expired. Risk factors for death being massive rebleeeding, comorbidities and Rockall score >6. Acute Upper Gastrointestinal bleeding is a medical emergency. Mortality is associated with massive bleeding, comorbidities and Rockall score >6. Urgent, appropriate hospital management definitely helps to reduce morbidity and mortality.

  8. Endoscopic stenting for benign upper gastrointestinal strictures and leaks.

    PubMed

    Sharaiha, Reem Z; Kim, Katherine J; Singh, Vikesh K; Lennon, Anne Marie; Amateau, Stuart K; Shin, Eun Ji; Canto, Marcia Irene; Kalloo, Anthony N; Khashab, Mouen A

    2014-01-01

    Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions. Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration. Thirty-eight patients (50 % male, mean age = 54 years, range = 12-82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18-118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38-762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction. Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of

  9. Airway Management During Upper GI Endoscopic Procedures: State of the Art Review.

    PubMed

    Goudra, Basavana; Singh, Preet Mohinder

    2017-01-01

    With the growing popularity of propofol mediated deep sedation for upper gastrointestinal (GI) endoscopic procedures, challenges are being felt and appreciated. Research suggests that management of the airway is anything but routine in this setting. Although many studies and meta-analyses have demonstrated the safety of propofol sedation administered by registered nurses under the supervision of gastroenterologists (likely related to the lighter degrees of sedation than those provided by anesthesia providers and is under medicolegal controversy in the United States), there is no agreement on the optimum airway management for procedures such as endoscopic retrograde cholangiopancreatography. Failure to rescue an airway at an appropriate time has led to disastrous consequences. Inability to evaluate and appreciate the risk factors for aspiration can ruin the day for both the patient and the health care providers. This review apprises the reader of various aspects of airway management relevant to the practice of sedation during upper GI endoscopy. New devices and modification of existing devices are discussed in detail. Recognizing the fact that appropriate monitoring is important for timely recognition and management of potential airway disasters, these issues are explored thoroughly.

  10. Therapeutic Decision-Making in Endoscopically Unmanageable Nonvariceal Upper Gastrointestinal Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Defreyne, Luc, E-mail: Luc.Defreyne@UGent.b; Schrijver, Ignace De; Decruyenaere, Johan

    2008-09-15

    The purpose of this study was to identify endoscopic and clinical parameters influencing the decision-making in salvage of endoscopically unmanageable, nonvariceal upper gastrointestinal hemorrhage (UGIH) and to report the outcome of selected therapy. We retrospectively retrieved all cases of surgery and arteriography for arrest of endoscopically unmanageable UGIH. Only patients with overt bleeding on endoscopy within the previous 24 h were included. Patients with preceding nonendoscopic hemostatic interventions, portal hypertension, malignancy, and transpapillar bleeding were excluded. Potential clinical and endoscopic predictors of allocation to either surgery or arteriography were tested using statistical models. Outcome and survival were regressed on themore » choice of rescue and clinical variables. Forty-six arteriographed and 51 operated patients met the inclusion criteria. Univariate analysis revealed a higher number of patients with a coagulation disorder in the catheterization group (41.4%, versus 20.4% in the laparotomy group; p = 0.044). With multivariate analysis, the identification of a bleeding peptic ulcer at endoscopy significantly steered decision-making toward surgical rescue (OR = 5.2; p = 0.021). Taking into account reinterventions, hemostasis was achieved in nearly 90% of cases in both groups. Overall therapy failure (no survivors), rebleeding within 3 days (OR = 3.7; p = 0.042), and corticosteroid use (OR = 5.2; p = 0.017) had a significant negative impact on survival. The odds of dying were not different for embolotherapy or surgery. In conclusion, decision-making was endoscopy-based, with bleeding peptic ulcer significantly directing the choice of rescue toward surgery. Unsuccessful hemostasis and corticosteroid use, but not the choice of rescue, negatively affected outcome.« less

  11. Endoscopic management of foreign bodies in the upper-GI tract: experience with 1088 cases in China.

    PubMed

    Li, Zhao-Shen; Sun, Zhen-Xing; Zou, Duo-Wu; Xu, Guo-Ming; Wu, Ren-Pei; Liao, Zhuan

    2006-10-01

    Reports on endoscopic management of ingested foreign bodies of the upper-GI tract in China are scarce. To report our experience and outcome in the management of ingestion of foreign bodies in Chinese patients. Between January 1980 and January 2005, a total of 1088 patients (685 men and 403 women; age range, 1 day to 96 years old) with suspected foreign bodies were admitted to our endoscopy center. All patients underwent endoscopic procedure after admission. Demographic and endoscopic data, including age, sex, and referral sources of patients, types, number and location of foreign bodies, associated upper-GI diseases, endoscopic methods, and accessory devices for removal of foreign bodies were collected and analyzed. A total of 1090 foreign bodies were found in 988 (90.8%) patients. The types of foreign bodies varied greatly: mainly food boluses, coins, fish bones, dental prostheses, or chicken bones. The foreign bodies were located in the pharynx (n = 12), the esophagus (n = 577), the stomach (n = 441), the duodenum (n = 50), and the surgical anastomosis (n = 10). The associated GI diseases (n = 88) included esophageal carcinoma (33.0%), stricture (23.9%), diverticulum (15.9%), postgastrectomy (11.4%), hiatal hernia (10.2%), and achalasia (5.7%). A rat-tooth forceps and a snare were the most frequently used accessory devices. The success rate for foreign-body removal was 94.1% (930/988). Ingestion of foreign bodies is a common clinic problem in China. Endoscopy procedures are frequently performed, and a high proportion of patients with foreign bodies require endoscopic intervention.

  12. Endoscopic approach to the upper cervical spine and clivus: an anatomical study of the upper limits of the transoral corridor.

    PubMed

    La Corte, Emanuele; Aldana, Philipp R

    2017-04-01

    Recent advances in endoscopic techniques have allowed minimally invasive approaches to the cranio-vertebral junction (CVJ) through the oropharynx (ETA) in addition to the transnasal approach (EEA). These minimally invasive endoscopic techniques allow for increased surgical exposure using no visible incisions, with a potential less morbidity. The ability to know preoperatively the limit of the ETA is vital for the surgical planning in order to better address CVJ pathology. The aim of the present study is to determine the anatomical limits of endoscopic dissection of the skull base and upper cervical spine through the transoral corridor and the superior limit reached by adopting this approach. Six fresh-frozen adult cadaver heads were dissected adopting ETA preserving the hard and soft palate. The most superior extent of the exposure was dissected. Post-operative CT scans were performed to confirm the superior extent. The superior most limit of dissection corresponded to the sphenoid-occipital junction, where the basilar portion of the occipital bone joins with the sphenoid bone's body. This ranged from 12.7 to 18.9 mm above the line of the hard palate. This was achieved without having to transgress any of the palatine structures. The sphenoid-occipital junction represents the rostral limit of endoscopic transoral approach to the lower skull base and CVJ area. This approach is limited superiorly by the orientation of the hard palate and mouth aperture and lower dentition due to the linear nature of the endoscope. Using the endoscope for this approach can allow for a more superior exposure than the traditional open transoral approach.

  13. Doppler Endoscopic Probe Monitoring of Blood Flow Improves Risk Stratification and Outcomes of Patients With Severe Nonvariceal Upper Gastrointestinal Hemorrhage.

    PubMed

    Jensen, Dennis M; Kovacs, Thomas O G; Ohning, Gordon V; Ghassemi, Kevin; Machicado, Gustavo A; Dulai, Gareth S; Sedarat, Alireza; Jutabha, Rome; Gornbein, Jeffrey

    2017-05-01

    For 4 decades, stigmata of recent hemorrhage in patients with nonvariceal lesions have been used for risk stratification and endoscopic hemostasis. The arterial blood flow that underlies the stigmata rarely is monitored, but can be used to determine risk for rebleeding. We performed a randomized controlled trial to determine whether Doppler endoscopic probe monitoring of blood flow improves risk stratification and outcomes in patients with severe nonvariceal upper gastrointestinal hemorrhage. In a single-blind study performed at 2 referral centers we assigned 148 patients with severe nonvariceal upper gastrointestinal bleeding (125 with ulcers, 19 with Dieulafoy's lesions, and 4 with Mallory Weiss tears) to groups that underwent standard, visually guided endoscopic hemostasis (control, n = 76), or endoscopic hemostasis assisted by Doppler monitoring of blood flow under the stigmata (n = 72). The primary outcome was the rate of rebleeding after 30 days; secondary outcomes were complications, death, and need for transfusions, surgery, or angiography. There was a significant difference in the rates of lesion rebleeding within 30 days of endoscopic hemostasis in the control group (26.3%) vs the Doppler group (11.1%) (P = .0214). The odds ratio for rebleeding with Doppler monitoring was 0.35 (95% confidence interval, 0.143-0.8565) and the number needed to treat was 7. In a randomized controlled trial of patients with severe upper gastrointestinal hemorrhage from ulcers or other lesions, Doppler probe guided endoscopic hemostasis significantly reduced 30-day rates of rebleeding compared with standard, visually guided hemostasis. Guidelines for nonvariceal gastrointestinal bleeding should incorporate these results. ClinicalTrials.gov no: NCT00732212 (CLIN-013-07F). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  14. Is Endoscopic Therapy Safe for Upper Gastrointestinal Bleeding in Anticoagulated Patients With Supratherapeutic International Normalized Ratios?

    PubMed

    Shim, Choong Nam; Chung, Hyun Soo; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan; Kim, Ha Yan; Kim, Dong Wook; Lee, Hyuk

    2016-01-01

    The management of upper gastrointestinal bleeding (UGIB) in anticoagulated patients with supratherapeutic international normalized ratios (INRs) presents a challenge. The purpose of the study was to evaluate the safety of endoscopic therapy for UGIB in anticoagulated patients with supratherapeutic INR in terms of rebleeding and therapeutic outcomes. One hundred ninety-two anticoagulated patients who underwent endoscopic treatment for UGIB were enrolled in the study. Patients were divided into 2 groups based on the occurrence of rebleeding within 30 days of the initial therapeutic endoscopy: no-rebleeding group (n = 168) and rebleeding group (n = 24). The overall rebleeding rate was 12.5%. Bleeding from gastric cancer and bleeding at the duodenum were significantly related to rebleeding in a univariate analysis. Multivariate analysis determined that presenting symptoms other than melena (hematemesis, hematochezia, or others) (odds ratio, 3.93; 95% confidence interval, 1.44-10.76) and bleeding from gastric cancer (odds ratio, 6.10; 95% confidence interval, 1.27-29.25) were significant factors predictive of rebleeding. Supratherapeutic INR at the time of endoscopic therapy was not significantly associated with rebleeding in either univariate or multivariate analysis. Significant differences in bleeding-related mortality, additional intervention to control bleeding, length of hospital stay, and transfusion requirements were revealed between the rebleeding and no-rebleeding groups. There were no significant differences in therapeutic outcomes between patients with INR within the therapeutic range and those with supratherapeutic INR. Supratherapeutic INR at the time of endoscopic therapy did not change rebleeding and therapeutic outcomes. Thus, we should consider endoscopic therapy for UGIB in anticoagulated patients, irrespective of INR at the time of endoscopic therapy.

  15. [Quality of diagnostic procedures and frequency of endoscopically defined diseases of the upper gastrointestinal tract].

    PubMed

    Bartels, F; Hahn, H-J; Stolte, M; Schmidt-Wilcke, H A

    2003-04-01

    The aim of this clinical investigation was to register the frequency of endoscopically defined diseases of the upper intestinal tract in a given region (Münster and Münsterland) within the period of one year (1.8.1999-31.7.2000). Furthermore, we tried to get an impression on the quality of the upper intestinoscopies by standardised conditions which had been developed by a steering committee (endoscopists and pathologists). 20 physicians (internal specialists and gastroenterologists) examined non-preselected patients and registered all relevant findings in the upper intestinal tract. The following items were of special interest: sex, age, operations in the past, indication, way of preparation, local findings (in the upper intestinal tract), and histological assessment. The examination forms were gathered, checked for completeness and evaluated statistically. Within the given period 8859 examinations forms (45.2% male and 54% female) could be evaluated. In 16% of the patients a reflux oesophagitis was diagnosed, three times more frequently than could have been expected anamnestically regarding the patients' complaints. In 274 patients (3%) the endoscopist suspected a Barrett's oesophagus; the according histological examination confirmed this suspicion in only 125 cases. Furthermore 17 adenocarcinomas and 13 squamous cell carcinomas were found. Macroscopically 44 polyps were registered but not all of them were biopsied. In 257 patients oesophageal varices (of varying degrees) were described. Only in 30.7% of the patients a H. pylori infection (diagnosed by urease test and by histological examination) was detected in the mucosa of the stomach. In 172 patients a gastritis was macroscopically suspected but the following histological assessments were not sufficient. The prevalence of gastric ulcers was 10 %, higher than the prevalence of duodenal ulcers. Only in 50% of the patients with a duodenal ulcer a H. pylori infection could be detected. In 51 cases carcinomas

  16. Etiological and Endoscopic Profile of Middle Aged and Elderly Patients with Upper Gastrointestinal Bleeding in a Tertiary Care Hospital in North India: A Retrospective Analysis.

    PubMed

    Mahajan, Pranav; Chandail, Vijant Singh

    2017-01-01

    Upper gastrointestinal (GI) bleeding is a common medical emergency associated with significant morbidity and mortality. The clinical presentation depends on the amount and location of hemorrhage and the endoscopic profile varies according to different etiology. At present, there are limited epidemiological data on upper GI bleed and associated mortality from India, especially in the middle and elderly age group, which has a higher incidence and mortality from this disease. This study aims to study the clinical and endoscopic profile of middle aged and elderly patients suffering from upper GI bleed to know the etiology of the disease and outcome of the intervention. Out of a total of 1790 patients who presented to the hospital from May 2015 to August 2017 with upper GI bleed, and underwent upper GI endoscopy, data of 1270 patients, aged 40 years and above, was compiled and analyzed retrospectively. All the patients included in the study were above 40 years of age. Majority of the patients were males, with a male to female ratio of 1.6:1. The most common causes of upper GI bleed in these patients were portal hypertension-related (esophageal, gastric and duodenal varices, portal hypertensive gastropathy, and gastric antral vascular ectasia GAVE), seen in 53.62% of patients, followed by peptic ulcer disease (gastric and duodenal ulcers) seen in 17.56% of patients. Gastric erosions/gastritis accounted for 15.20%, and duodenal erosions were seen in 5.8% of upper GI bleeds. The in-hospital mortality rate in our study population was 5.83%. The present study reported portal hypertension as the most common cause of upper GI bleeding, while the most common endoscopic lesions reported were esophageal varices, followed by gastric erosion/gastritis, and duodenal ulcer.

  17. The fourth space surgery: endoscopic subserosal dissection for upper gastrointestinal subepithelial tumors originating from the muscularis propria layer.

    PubMed

    Liu, Fei; Zhang, Song; Ren, Wei; Yang, Tian; Lv, Ying; Ling, Tingsheng; Zou, Xiaoping; Wang, Lei

    2018-05-01

    We developed a novel method of endoscopic subserosal dissection (ESSD) for removal of subepithelial tumors (SETs) originating from the muscularis propria (MP) layer in the upper gastrointestinal (GI) tract. The aim of this study was to evaluate the efficacy, safety, and clinical outcome of this method. Eleven patients with upper GI SETs originating from the MP layer were treated by ESSD between October 2016 and March 2017. ESSD technique consists of six major procedures: (1) incising the mucosal and submucosal layer around the lesion and exposing MP layer; (2) continuous injection was performed while the injection needle slowly moved from the MP layer toward the subserosal layer; (3) incising MP layer; (4) subserosal injection was performed to further separate the serosa from the MP layer; (5) the mucosa, submucosa, and MP layer including SET were carefully dissected en bloc; and (6) closure of the gastric-wall defect with endoscopic techniques. Primary outcome including clinical procedural success and procedure-related adverse events were documented. ESSD was successfully performed in 11 patients. The complete resection rate was 100%, and the mean operation time was 51 (range 22-76) min. The mean resected lesion size was 27 (range 15-40) mm. Pathological diagnosis of these lesions included gastrointestinal stromal tumors (8/11), heterotopic pancreas (1/11), hamartoma (1/11), and leiomyoma (1/11). The small perforations occurred in two patients (4 × 4 and 5 × 5 mm, respectively) during the operation. All perforations and defects were closed successfully by endoscopic techniques. No GI bleeding, peritonitis, abdominal abscess, and other adverse events were observed. No lesion residual or recurrence was found during the follow-up period (mean 18 weeks; range 10-29 weeks). ESSD seems to be an efficacious, safe, and minimally invasive treatment for patients with upper GI SETs originating from the MP layer, making it possible to resect deep lesions, provide

  18. Effectiveness of endoscopic cricopharyngeal myotomy in adults with neurological disease: systematic review.

    PubMed

    Gilheaney, Ó; Kerr, P; Béchet, S; Walshe, M

    2016-12-01

    To determine the effectiveness of endoscopic cricopharyngeal myotomy on upper oesophageal sphincter dysfunction in adults with upper oesophageal sphincter dysfunction and neurological disease. Published and unpublished studies with a quasi-experimental design investigating endoscopic cricopharyngeal myotomy effects on upper oesophageal sphincter dysfunction in humans were considered eligible. Electronic databases, grey literature and reference lists of included studies were systematically searched. Data were extracted by two independent reviewers. Methodological quality was assessed independently using the PEDro scale and MINORS tool. Of 2938 records identified, 2 studies were eligible. Risk of bias assessment indicated areas of methodological concern in the literature. Statistical analysis was not possible because of the limited number of eligible studies. No determinations could be made regarding endoscopic cricopharyngeal myotomy effectiveness in the cohort of interest. Reliable and valid evidence on the following is required to support increasing clinical usage of endoscopic cricopharyngeal myotomy: optimal candidacy selection; standardised post-operative management protocol; complications; and endoscopic cricopharyngeal myotomy effects on aspiration of food and laryngeal penetration, mean upper oesophageal sphincter resting pressure and quality of life.

  19. Review of Pure Endoscopic Full-Thickness Resection of the Upper Gastrointestinal Tract

    PubMed Central

    Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Masaki, Tsutomu

    2015-01-01

    Natural-orifice transluminal endoscopic surgery (NOTES) using flexible endoscopy has attracted attention as a minimally invasive surgical method that does not cause an operative wound on the body surface. However, minimizing the number of devices involved in endoscopic, compared to laparoscopic, surgeries has remained a challenge, causing endoscopic surgeries to gradually be phased out of use. If a flexible endoscopic full-thickness suturing device and a counter-traction device were developed to expand the surgical field for gastrointestinal-tract collapse, then endoscopic full-thickness resection using NOTES, which is seen as an extension of endoscopic submucosal dissection for full-thickness excision of tumors involving the gastrointestinal-tract wall, might become an extremely minimally invasive surgical method that could be used to resect only full-thickness lesions approached by the shortest distance via the mouth. It is expected that gastroenterological endoscopists will use this surgery if device development is advanced. This extremely minimally invasive surgery would have an immeasurable impact with regard to mitigating the burden on patients and reducing healthcare costs. Development of a new surgical method using a multipurpose flexible endoscope is therefore considered a socially urgent issue. PMID:26343069

  20. Long-term exercising video-endoscopic examination of the upper airway following laryngoplasty surgery: a prospective cross-sectional study of 41 horses.

    PubMed

    Barnett, T P; O'Leary, J M; Parkin, T D H; Dixon, P M; Barakzai, S Z

    2013-09-01

    To investigate upper respiratory tract function in horses, previously undergoing laryngoplasty (LP), using exercising video-endoscopy. To evaluate arytenoid abduction and stability, diagnose any concurrent upper airway problems, and correlate these with the owners' perception of success. Horses undergoing LP during a 6-year period at one hospital were initially included. Those available for re-examination were exercised for a duration and intensity considered maximal for their discipline using an over-ground endoscope. Resting and exercising laryngeal and pharyngeal videos were analysed blindly. Multivariable analysis was used to test associations between resting and exercising endoscopic variables, and also between endoscopic variables and owner questionnaire findings. Forty-one horses were included and 78% had a form of upper airway collapse at exercise, with 41% having complex forms, despite 93% of owners reporting the surgery to have been beneficial. Horses with poor abduction (grades 4 or 5/5) were 6 times more likely to make respiratory noise compared with those with good (grades 2 or 3/5) abduction (P = 0.020; 95% confidence interval [CI] 1.3-27.0), and those not having a ventriculectomy were 4.9 times more likely to produce respiratory noise post operatively (P = 0.048; 95% CI 1.0-23.9). Palatal dysfunction was observed in 24% of horses at rest, and 56% at exercise, with the diagnosis at rest and exercise significantly associated (P = 0.001). Increasing severity of pharyngeal lymphoid hyperplasia (prevalence 61%) was significantly associated with increasing arytenoid abduction (P = 0.01). Thirty-four per cent of horses had aryepiglottic fold collapse and 22% of horses had vocal fold collapse. Many horses that had previously had LP were diagnosed with upper airway abnormalities, despite the procedure being considered as beneficial by most owners. When investigating cases of ongoing respiratory noise or poor performance following LP, exercising endoscopy must

  1. Embolization of Acute Nonvariceal Upper Gastrointestinal Hemorrhage Resistant to Endoscopic Treatment: Results and Predictors of Recurrent Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loffroy, Romaric, E-mail: romaric.loffroy@yahoo.fr; Rao, Pramod; Ota, Shinichi

    2010-12-15

    Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such as Dieulafoy lesions; Mallory-Weiss tears; trauma; and iatrogenic causes. Aggressive treatment with early endoscopic hemostasis is essential for a favorable outcome. However, severe bleeding despite conservative medical treatment or endoscopic intervention occurs in 5-10% of patients, requiring surgery or transcatheter arterial embolization. Surgical intervention is usually an expeditious and gratifying endeavor, but it can be associated with high operativemore » mortality rates. Endovascular management using superselective catheterization of the culprit vessel, < sandwich> occlusion, or blind embolization has emerged as an alternative to emergent operative intervention for high-risk patients and is now considered the first-line therapy for massive UGI bleeding refractory to endoscopic treatment. Indeed, many published studies have confirmed the feasibility of this approach and its high technical and clinical success rates, which range from 69 to 100% and from 63 to 97%, respectively, even if the choice of the best embolic agent among coils, cyanaocrylate glue, gelatin sponge, or calibrated particles remains a matter of debate. However, factors influencing clinical outcome, especially predictors of early rebleeding, are poorly understood, and few studies have addressed this issue. This review of the literature will attempt to define the role of embolotherapy for acute nonvariceal UGI hemorrhage that fails to respond to endoscopic hemostasis and to summarize data on factors predicting angiographic and embolization failure.« less

  2. Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract.

    PubMed

    Lien, Gi-Shih; Wu, Ming-Shun; Chen, Chun-Nan; Liu, Chih-Wen; Suk, Fat-Moon

    2018-04-01

    Current capsule endoscopy procedures are ineffective for upper gastrointestinal (GI) tract examination because they do not allow for operator-controlled navigation of the capsule. External controllability of a capsule endoscope with an applied magnetic field is a possible solution to this problem. We developed a novel magnetic-assisted capsule endoscope (MACE) system to visualize the entire upper GI tract. The present study evaluated the safety and feasibility of the MACE system for the examination of the upper GI tract, including the esophagus, stomach, and duodenum. The present open clinical study enrolled ten healthy volunteers. All participants swallowed a MACE, and an external magnetic field navigator was used for magnetic capsule manipulation in the upper GI tract. We assessed the maneuverability of the magnetic capsule and completeness of the MACE examination as well as the safety and tolerability of the procedure. The present study enrolled ten healthy volunteers with a mean age and body mass index of 47.7 years and 25.6 kg/m 2 , respectively. One volunteer withdrew because of difficulty in swallowing the capsule. In total, nine volunteers underwent the MACE examination. The average examination time was 27.1 min. The maneuverability of the capsule was assessed as good and fair in 55.6 and 44.4% of the participants, respectively. The overall completeness of the examination in the esophagus, stomach, and duodenum was 100, 85.2, and 86.1%, respectively. No severe adverse events occurred during this study. All participants exhibited satisfactory tolerance of the MACE examination. The MACE system has satisfactory maneuverability and visualization completeness with excellent acceptance and tolerance.

  3. Oncologic results of nephron sparing endoscopic approach for upper tract low grade transitional cell carcinoma in comparison to nephroureterectomy - a case control study.

    PubMed

    Hoffman, Azik; Yossepowitch, Ofer; Erlich, Yaron; Holland, Ronen; Lifshitz, David

    2014-12-02

    There is paucity of data as to the results of the endoscopic approach in comparison to the golden standard of nephro-ureterectomy in elective, low grade TCC, patients. Our purpose is to report our results of a nephron sparing approach compared to nephro-ureterectomy in those patients. From a retrospective data base we identified 25 patients and 23 patients who underwent a nephron sparing ureterosocpic resection and nephro-reterectomy for low grade UT-TCC, respectively. The endoscopic technique included endoscopic tumor biopsy followed by primary resection and/or fulguration. The nephron sparing group was followed by bi-annual ureteroscopy and upper tract imaging, timely cystoscopy and urine cytology collection. Data for overall and disease related mortality, bladder and ureteral TCC recurrence and renal function are reported in both groups. Median follow - up time was 26 months. 11 (44%) patients developed bladder recurrence at a median period of 9 months after initial ureteroscopy, compared to 9 (39%) in the NUx group (P < 0.05). Recurrent ureteral low grade TCC was observed in 9 patients (median: 9 months). All were treated endoscopicaly successfully. Renal function remained stable in the nephron sparing group. No disease related mortality was recorded in the nephron-sparing group while one patient died of his disease following NUx. Disease related mortality following a nephron sparing endoscopic approach or nephroureterectomy for low grade upper tract TCC is excellent. However, the nephron sparing approach is associated with a relatively high rate of ureteral and bladder recurrence. Therefore, a stringent follow-up protocol is required.

  4. Posterior Percutaneous Endoscopic Cervical Foraminotomy and Diskectomy With Unilateral Biportal Endoscopy.

    PubMed

    Park, Jae Hyun; Jun, Su Gi; Jung, Je Tae; Lee, Sang Jin

    2017-09-01

    This report describes a new, minimally invasive procedure, posterior percutaneous endoscopic cervical diskectomy, performed with a unilateral biportal endoscopic approach. The procedure is used to treat cervical foraminal soft disk protrusion. This report also describes the short-term results with this procedure. In 2015, 14 patients underwent this new, minimally invasive procedure. The technique was applied with a standard arthroscopy device and conventional spine instruments. The Neck Disability Index and visual analog scale scores for the neck and upper arm were evaluated, and 13 consecutive patients were included in the analysis. Mean follow-up was 14.8 months (range, 12-18 months). The Neck Disability Index decreased from 27.0±2.5 to 6.8±1.4 at the last follow-up (P<.05). Visual analog scale scores for the neck and upper arm also decreased significantly (neck, 6.2±0.8 to 2.4±0.9; upper arm, 7.0±1.1 to 2.2±0.6). Posterior percutaneous endoscopic cervical diskectomy with a uniportal endoscope provides a clear operative field because of continuous endoscopic saline irrigation and requires only a short hospitalization and no postoperative rehabilitation. Posterior percutaneous endoscopic cervical diskectomy with a unilateral biportal endoscopic approach also can be performed efficiently because of the wide field of visualization and familiar surgical field. Thus, posterior percutaneous endoscopic cervical diskectomy with the unilateral biportal endoscopic approach may be an alternative procedure for cervical foraminal soft disk protrusion. [Orthopedics. 2017; 40(5):e779-e783.]. Copyright 2017, SLACK Incorporated.

  5. Clinical outcomes of endoscopic submucosa dissection for high-grade dysplasia from endoscopic forceps biopsy.

    PubMed

    Ryu, Dae Gon; Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Nam, Hyeong Seok

    2017-07-01

    Although the Vienna Classification recommends endoscopic resection for gastric high-grade dysplasia (HGD), many resected lesions are diagnosed as gastric cancer after endoscopic resection. This study aims to evaluate the clinical outcomes of gastric HGD identified by endoscopic forceps biopsy (EFB) after endoscopic submucosal dissection (ESD) and factors associated with discrepant results. From December 2008 to July 2015, a total of 427 lesions diagnosed as initial HGD by EFB were enrolled. The rate of early gastric cancer (EGC) and factors predicting diagnosis upgrade were analyzed retrospectively. Tumors ranged between 2 and 65 mm in size (median 12.59). En bloc and complete resection rates were 97.4 and 95.3%, respectively. The diagnostic discrepancy rate was 76.3%. Upgrade and downgrade rates of pathological diagnoses were 66.5 and 9.8%, respectively. Central depression (OR 4.151), nodular surface (OR 5.582), surface redness (OR 2.926), lesion location (upper third of the stomach) (OR 3.894), and tumor size ≥10 mm (OR 2.287) were significantly associated with EGC. Nodular surface (OR 2.746), submucosal fibrosis (OR 3.958), lesion location (upper third of the stomach) (OR 6.652), and tumor size ≥10 mm (OR 4.935) significantly predicted invasive submucosal cancer. Central depression, nodular surface, surface redness, lesion location, large tumor size, and submucosal fibrosis were associated with EGC or submucosal cancer. Caution must be used in treating lesions with these features with ESD.

  6. Endoscopic Bubble Trouble: Hyperbaric Oxygen Therapy for Cerebral Gas Embolism During Upper Endoscopy.

    PubMed

    Cooper, Jeffrey S; Thomas, Jason; Singh, Shailender; Brakke, Tarra

    2017-07-01

    Gas embolism is a rare but potentially devastating complication of endoscopic procedures. We describe 3 cases of gas embolism which were associated with endoscopic procedures (esophagogastroduodenoscopy and endoscopic retrograde cholangiopancreatography). We treated these at our hyperbaric medicine center with 3 different outcomes: complete resolution, death, and disability. We review the literature regarding this unusual complication of endoscopy and discuss the need for prompt identification and referral for hyperbaric oxygen therapy. Additional adjunctive therapies are also discussed.

  7. Trends in upper gastrointestinal diagnosis over four decades in Lusaka, Zambia: a retrospective analysis of endoscopic findings.

    PubMed

    Kayamba, Violet; Sinkala, Edford; Mwanamakondo, Stayner; Soko, Rose; Kawimbe, Boniface; Amadi, Beatrice; Zulu, Isaac; Nzaisenga, Jean-Baptiste; Banda, Themba; Mumbwe, Chipasha; Phiri, Evans; Munkonge, Philip; Kelly, Paul

    2015-10-06

    There a shortage of robust information about profiles of gastrointestinal disease in sub-Saharan Africa. The endoscopy unit of the University Teaching Hospital in Lusaka has been running without interruption since 1977 and this 38-year record is largely intact. We report an analysis of endoscopic findings over this period. Written endoscopy records from 29th September 1977 to 16th December 2014 were recovered, computerised, coded by two experienced endoscopists and analysed. Temporal trends were analysed using tables, graphs, and unconditional logistic regression, with age, sex of patient, decade, and endoscopist as independent variables to adjust for inter-observer variation. Sixteen thousand nine hundred fifty-three records were identified and analysed. Diagnosis of gastric ulcer rose by 22 %, and that of duodenal ulcer fell by 14 % per decade. Endoscopically diagnosed oesophageal cancer increased by 32 % per decade, but gastric cancer rose only in patients under 60 years of age (21 % per decade). Oesophageal varices were the commonest finding in patients presenting with haematemesis, increasing by 14 % per decade in that patient group. Two HIV-related diagnoses, oesophageal candidiasis and Kaposi's sarcoma, rose from almost zero to very high levels in the 1990s but fell substantially after 2005 when anti-retroviral therapy became widely available. This useful dataset suggests that there are important trends in some endoscopic findings over four decades. These trends are not explained by inter-observer variation. Reasons for the divergent trends in incidence of peptic ulceration and apparent trends in diagnosis of upper gastrointestinal cancers merit further exploration.

  8. Endoscopic Dacrocystorhinostomy in Lacrimal Canalicular Trauma

    PubMed Central

    Khan, Humayun A; Bayat, Aredeshir; De Carpentier, JP

    2007-01-01

    A case is presented where the common insertion of the upper and lower canaliculus of the lacrimal sac was repaired using endoscopic dacrocystorhinostomy (DCR) techniques, with silicone stenting and securing of stents intranasally. PMID:17316509

  9. Predictive Factors of Atelectasis Following Endoscopic Resection.

    PubMed

    Choe, Jung Wan; Jung, Sung Woo; Song, Jong Kyu; Shim, Euddeum; Choo, Ji Yung; Kim, Seung Young; Hyun, Jong Jin; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo

    2016-01-01

    Atelectasis is one of the pulmonary complications associated with anesthesia. Little is known about atelectasis following endoscopic procedures under deep sedation. This study evaluated the frequency, risk factors, and clinical course of atelectasis after endoscopic resection. A total of 349 patients who underwent endoscopic resection of the upper gastrointestinal tract at a single academic tertiary referral center from March 2010 to October 2013 were enrolled. Baseline characteristics and clinical data were retrospectively reviewed from medical records. To identify atelectasis, we compared the chest radiography taken before and after the endoscopic procedure. Among the 349 patients, 68 (19.5 %) had newly developed atelectasis following endoscopic resection. In univariate logistic regression analysis, atelectasis correlated significantly with high body mass index, smoking, diabetes mellitus, procedure duration, size of lesion, and total amount of propofol. In multiple logistic regression analysis, body mass index, procedure duration, and total propofol amount were risk factors for atelectasis following endoscopic procedures. Of the 68 patients with atelectasis, nine patients developed fever, and six patients displayed pneumonic infiltration. The others had no symptoms related to atelectasis. The incidence of radiographic atelectasis following endoscopic resection was nearly 20 %. Obesity, procedural time, and amount of propofol were the significant risk factors for atelectasis following endoscopic procedure. Most cases of the atelectasis resolved spontaneously with no sequelae.

  10. Validation of a new menstrual pictogram (superabsorbent polymer-c version) for use with ultraslim towels that contain superabsorbent polymers.

    PubMed

    Magnay, Julia L; Nevatte, Tracy M; O'Brien, Shaughn; Gerlinger, Christoph; Seitz, Christian

    2014-02-01

    To validate the menstrual pictogram (superabsorbent polymer-c version) for Always Ultra-slim feminine towels containing superabsorbent polymers. Prospective, multicenter, evaluator-blinded study. Three gynecology research clinics in the United Kingdom. Women with self-perceived light, normal, or heavy menstrual periods who had not previously used a graphical method to assess their menstrual loss. One hundred twenty-two women were asked to complete the menstrual pictogram throughout two menstrual periods and collect their feminine towels for measurements of menstrual blood loss (MBL) by the alkaline hematin method and total menstrual fluid loss (MFL) by fluid weight. Agreement of menstrual pictogram MBL and MFL scores with alkaline hematin and towel weight, respectively. The percentage blood fraction was determined at various volumes of menstrual discharge. Alkaline hematin and fluid weight were highly correlated (r = .97). However, the percentage blood fraction progressively increased with total MFL and MBL score. After correction for this incremental rise in blood fraction, the menstrual pictogram gave a sensitivity of 82% and a specificity of 92% for a diagnosis of heavy menstrual bleeding. The menstrual pictogram (superabsorbent polymer-c version) provides a simple means of measuring MBL in the clinical setting. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Endoscopic Management of Tumor Bleeding from Inoperable Gastric Cancer

    PubMed Central

    Kim, Young-Il

    2015-01-01

    Tumor bleeding is not a rare complication in patients with inoperable gastric cancer. Endoscopy has important roles in the diagnosis and primary treatment of tumor bleeding, similar to its roles in other non-variceal upper gastrointestinal bleeding cases. Although limited studies have been performed, endoscopic therapy has been highly successful in achieving initial hemostasis. One or a combination of endoscopic therapy modalities, such as injection therapy, mechanical therapy, or ablative therapy, can be used for hemostasis in patients with endoscopic stigmata of recent hemorrhage. However, rebleeding after successful hemostasis with endoscopic therapy frequently occurs. Endoscopic therapy may be a treatment option for successfully controlling this rebleeding. Transarterial embolization or palliative surgery should be considered when endoscopic therapy fails. For primary and secondary prevention of tumor bleeding, proton pump inhibitors can be prescribed, although their effectiveness to prevent bleeding remains to be investigated. PMID:25844339

  12. How to predict a high rate of inappropriateness for upper endoscopy in an endoscopic centre?

    PubMed

    Buri, L; Bersani, G; Hassan, C; Anti, M; Bianco, M A; Cipolletta, L; Di Giulio, E; Di Matteo, G; Familiari, L; Ficano, L; Loriga, P; Morini, S; Pietropaolo, V; Zambelli, A; Grossi, E; Intraligi, M; Tessari, F; Buscema, M

    2010-09-01

    Inappropriateness of upper endoscopy (EGD) indication causes decreased diagnostic yield. Our aim of was to identify predictors of appropriateness rate for EGD among endoscopic centres. A post-hoc analysis of two multicentre cross-sectional studies, including 6270 and 8252 patients consecutively referred to EGD in 44 (group A) and 55 (group B) endoscopic Italian centres in 2003 and 2007, respectively, was performed. A multiple forward stepwise regression was applied to group A, and independently validated in group B. A <70% threshold was adopted to define inadequate appropriateness rate clustered by centre. discrete variability of clustered appropriateness rates among the 44 group A centres was observed (median: 77%; range: 41-97%), and a <70% appropriateness rate was detected in 11 (25%). Independent predictors of centre appropriateness rate were: percentage of patients referred by general practitioners (GP), rate of urgent examinations, prevalence of relevant diseases, and academic status. For group B, sensitivity, specificity and area under receiver operating characteristic curve of the model in detecting centres with a <70% appropriateness rate were 54%, 93% and 0.72, respectively. A simple predictive rule, based on rate of patients referred by GPs, rate of urgent examinations, prevalence of relevant diseases and academic status, identified a small subset of centres characterised by a high rate of inappropriateness. These centres may be presumed to obtain the largest benefit from targeted educational programs. Copyright (c) 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Endoscopic Management of Foreign Bodies in the Upper Gastrointestinal Tract of Adults

    PubMed Central

    Yao, Chih-Chien; Wu, I-Ting; Lu, Lung-Sheng; Lin, Sheng-Chieh; Liang, Chih-Ming; Kuo, Yuan-Hung; Yang, Shih-Cheng; Wu, Cheng-Kun; Wang, Hsing-Ming; Kuo, Chung-Huang; Chiou, Shue-Shian; Wu, Keng-Liang; Chiu, Yi-Chun; Chuah, Seng-Kee; Tai, Wei-Chen

    2015-01-01

    Background. Foreign object ingestion and food bolus impaction are a common clinical problem. We report our clinical experiences in endoscopic management for adults, foreign body ingestion, and food bolus impaction. Method. A retrospective chart review study was conducted on adult patients with foreign body ingestion and food bolus impaction between January 2011 and November 2014. Patients with incomplete medical records were excluded. Results. A total of 198 patients (226 incidents) were included in the study (male/female: 1.54/1; age 57 ± 16 years). Among them, 168 foreign bodies were found successfully (74.3%). 75.6% of the foreign bodies were located in the esophagus. Food bolus impaction was most common (41.6%). 93.5% of foreign bodies in current study cohort were successfully extracted and 5 patients required surgical interventions. Comparisons between symptomatic and asymptomatic patients revealed that locations of foreign bodies in the pharynx and esophagus were the significant relevant factors (P < 0.001). Shorter time taken to initiate endoscopic interventions increased detection rate (289.75 ± 465.94 versus 471.06 ± 659.93 minutes, P = 0.028). Conclusion. Endoscopic management is a safe and highly effective procedure in extracting foreign body ingestion and food bolus impaction. Prompt endoscopic interventions can increase the chance of successful foreign bodies' detection. PMID:26258140

  14. Endoscopic Management of Foreign Bodies in the Upper Gastrointestinal Tract of Adults.

    PubMed

    Yao, Chih-Chien; Wu, I-Ting; Lu, Lung-Sheng; Lin, Sheng-Chieh; Liang, Chih-Ming; Kuo, Yuan-Hung; Yang, Shih-Cheng; Wu, Cheng-Kun; Wang, Hsing-Ming; Kuo, Chung-Huang; Chiou, Shue-Shian; Wu, Keng-Liang; Chiu, Yi-Chun; Chuah, Seng-Kee; Tai, Wei-Chen

    2015-01-01

    Foreign object ingestion and food bolus impaction are a common clinical problem. We report our clinical experiences in endoscopic management for adults, foreign body ingestion, and food bolus impaction. A retrospective chart review study was conducted on adult patients with foreign body ingestion and food bolus impaction between January 2011 and November 2014. Patients with incomplete medical records were excluded. A total of 198 patients (226 incidents) were included in the study (male/female: 1.54/1; age 57 ± 16 years). Among them, 168 foreign bodies were found successfully (74.3%). 75.6% of the foreign bodies were located in the esophagus. Food bolus impaction was most common (41.6%). 93.5% of foreign bodies in current study cohort were successfully extracted and 5 patients required surgical interventions. Comparisons between symptomatic and asymptomatic patients revealed that locations of foreign bodies in the pharynx and esophagus were the significant relevant factors (P < 0.001). Shorter time taken to initiate endoscopic interventions increased detection rate (289.75 ± 465.94 versus 471.06 ± 659.93 minutes, P = 0.028). Endoscopic management is a safe and highly effective procedure in extracting foreign body ingestion and food bolus impaction. Prompt endoscopic interventions can increase the chance of successful foreign bodies' detection.

  15. A case of gastric hamartomatous inverted polyp resected endoscopically

    PubMed Central

    Dohi, Moyu; Gen, Yasuyuki; Yoshioka, Mika

    2016-01-01

    We report the case of a 55-year-old woman with a tumor in the greater curvature of the upper gastric body. The tumor was incidentally found on an upper gastrointestinal X-ray series performed during a routine medical examination. Whereas endoscopy revealed a gastric submucosal tumor (SMT), endoscopic ultrasonography demonstrated a heterogeneous tumor with small, cystic, hypoechoic spots originating from the second layer. The patient was clinically asymptomatic, with no contributory family history or abnormal laboratory data. The results of a physical examination, abdominal computed tomography, and plain chest radiography were all unremarkable. Although the endoscopic tumor type was determined to be SMT, the tumor was successfully resected by endoscopic submucosal dissection (ESD) and subsequently diagnosed as a gastric hamartomatous inverted polyp (GHIP). The findings of the present case highlight the importance of considering GHIP as a diagnosis and indicate the utility of en bloc resection of GHIP with ESD. PMID:27556064

  16. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    PubMed

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  17. Endoscopic techniques and management of foreign body ingestion and food bolus impaction in the upper gastrointestinal tract: a retrospective analysis of 139 cases.

    PubMed

    Katsinelos, Panagiotis; Kountouras, Jannis; Paroutoglou, George; Zavos, Christos; Mimidis, Kostas; Chatzimavroudis, Grigoris

    2006-10-01

    Ingested foreign bodies and food bolus impaction are frequently seen in endoscopic practice. Successful foreign body and food bolus removal may depend on the method used, the choice of device, and the experience level of the endoscopist, although few papers report experience and outcome of tertiary centers. To investigate the effectiveness of our protocol designed for removal of ingested foreign bodies and food boluses. We retrospectively reviewed all patients with a diagnosis of foreign body ingestion and food bolus impaction from 1994 to 2005 identified by computer search. Patients were excluded if medical record was incomplete. The analysis included 171 patients. Foreign bodies and impacted food boluses were found in 77 and 62 patients, respectively. In 32 cases (23%), the foreign bodies passed spontaneously through the gastrointestinal tract. The overall success rate for endoscopic management was obtained in 137 patients (98.6%). Surgical removal of a foreign body was required in only 2 cases (1.4%). According to the type and location of the foreign object and food bolus we used Dormia baskets, retrieval forceps, polypectomy snares, and all sizes of Roth net. No complications relating to the endoscopic procedure were observed; 50 patients (35.2%) had an underlying esophageal disease. Endoscopic removal of upper gastrointestinal tract foreign bodies and food bolus impaction is efficacious and safe. Especially the Roth net is the best device for safe retrieval of food boluses and button disc batteries.

  18. Endoscopic submucosal tunnel dissection of upper gastrointestinal submucosal tumors: A comparative study of hook knife vs hybrid knife.

    PubMed

    Zhou, Jie-Qiong; Tang, Xiao-Wei; Ren, Yu-Tang; Wei, Zheng-Jie; Huang, Si-Lin; Gao, Qiao-Ping; Zhang, Xiao-Feng; Yang, Jian-Feng; Gong, Wei; Jiang, Bo

    2017-03-14

    To compare the efficacy and safety of a hook knife (HO) with a hybrid knife (HK) during endoscopic submucosal tunnel dissection (ESTD) procedure. Between August 2012 and December 2015, the ESTD procedure was performed for 83 upper GI submucosal lesions, which originated from the muscularis propria layer identified by upper endoscopy and endoscopic ultrasonography. Of these, 34 lesions were treated by a HO, whereas 49 lesions were treated by a HK. Data regarding age, gender, presenting symptoms, tumor location and size, procedure time, complications, en bloc resection rate and others were analyzed and compared between the two groups. There were no significant differences in the age, gender, presenting symptoms and tumor location between the two groups. ESTD was successfully completed in all the patients, and no case was converted to laparoscopy. The mean procedure time was significantly shorter in the HK group than in the HO group (41.3 ± 20.3 min vs 57.2 ± 28.0 min, P = 0.004). The mean frequency of device exchange was 1.4 ± 0.6 in the HK group and significantly less than 3.3 ± 0.6 in the HO group ( P < 0.001). The differences in tumor size and histopathological diagnoses were not significant between the two groups ( P = 0.813, P = 0.363, respectively). Both groups had an equal en bloc resection rate and complete resection rate. Additionally, the complication rate was similar between the two groups ( P = 0.901). During the follow-up, no recurrence occurred in either group. We demonstrate for the first time that HO and HK do not differ in efficacy or safety, but HK reduces the frequency of device exchange and procedure time.

  19. Upper gastrointestinal bleeding.

    PubMed

    Feinman, Marcie; Haut, Elliott R

    2014-02-01

    Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Risk factors for complications associated with upper gastrointestinal foreign bodies

    PubMed Central

    Hong, Kyong Hee; Kim, Yoon Jae; Kim, Jae Hak; Chun, Song Wook; Kim, Hee Man; Cho, Jae Hee

    2015-01-01

    AIM: To investigate predictive risk factors associated with complications in the endoscopic removal of foreign bodies from the upper gastrointestinal tract. METHODS: We retrospectively reviewed the medical records of 194 patients with a diagnosis of foreign body impaction in the upper gastrointestinal tract, confirmed by endoscopy, at two university hospital in South Korea. Patient demographic data, including age, gender, intention to ingestion, symptoms at admission, and comorbidities, were collected. Clinical features of the foreign bodies, such as type, size, sharpness of edges, number, and location, were analyzed. Endoscopic data those were analyzed included duration of foreign body impaction, duration of endoscopic performance, endoscopic device, days of hospitalization, complication rate, 30-d mortality rate, and the number of operations related to foreign body removal. RESULTS: The types of upper gastrointestinal foreign bodies included fish bones, drugs, shells, meat, metal, and animal bones. The locations of impacted foreign bodies were the upper esophagus (57.2%), mid esophagus (28.4%), stomach (10.8%), and lower esophagus (3.6%). The median size of the foreign bodies was 26.2 ± 16.7 mm. Among 194 patients, endoscopic removal was achieved in 189, and complications developed in 51 patients (26.9%). Significant complications associated with foreign body impaction and removal included deep lacerations with minor bleeding (n = 31, 16%), ulcer (n = 11, 5.7%), perforation (n = 3, 1.5%), and abscess (n = 1, 0.5%). Four patients underwent operations because of incomplete endoscopic foreign body extraction. In multivariate analyses, risk factors for endoscopic complications and failure were sharpness (HR = 2.48, 95%CI: 1.07-5.72; P = 0.034) and a greater than 12-h duration of impaction (HR = 2.42, 95%CI: 1.12-5.25, P = 0.025). CONCLUSION: In cases of longer than 12 h since foreign body ingestion or sharp-pointed objects, rapid endoscopic intervention should be

  2. Upper gastrointestinal alterations in kidney transplant candidates.

    PubMed

    Homse Netto, João Pedro; Pinheiro, João Pedro Sant'Anna; Ferrari, Mariana Lopes; Soares, Mirella Tizziani; Silveira, Rogério Augusto Gomes; Maioli, Mariana Espiga; Delfino, Vinicius Daher Alvares

    2018-05-14

    The incidence of gastrointestinal disorders among patients with chronic kidney disease (CKD) is high, despite the lack of a good correlation between endoscopic findings and symptoms. Many services thus perform upper gastrointestinal (UGI) endoscopy on kidney transplant candidates. This study aims to describe the alterations seen on the upper endoscopies of 96 kidney-transplant candidates seen from 2014 to 2015. Ninety-six CKD patients underwent upper endoscopic examination as part of the preparation to receive kidney grafts. The data collected from the patients' medical records were charted on Microsoft Office Excel 2016 and presented descriptively. Mean values, medians, interquartile ranges and 95% confidence intervals of the clinic and epidemiological variables were calculated. Possible associations between endoscopic findings and infection by H. pylori were studied. Males accounted for 54.17% of the 96 patients included in the study. Median age and time on dialysis were 50 years and 50 months, respectively. The most frequent upper endoscopy finding was enanthematous pangastritis (57.30%), followed by erosive esophagitis (30.20%). Gastric intestinal metaplasia and peptic ulcer were found in 8.33% and 7.30% of the patients, respectively. H. pylori tests were positive in 49 patients, and H. pylori infection was correlated only with non-erosive esophagitis (P = 0.046). Abnormal upper endoscopy findings were detected in all studied patients. This study suggested that upper endoscopy is a valid procedure for kidney transplant candidates. However, prospective studies are needed to shed more light on this matter.

  3. Removal of press-through-packs impacted in the upper esophagus using an overtube.

    PubMed

    Seo, Yeon-Seok; Park, Jong-Jae; Kim, Ji-Hoon; Kim, Jin-Yong; Yeon, Jong-Eun; Kim, Jae-Seon; Byun, Kwan-Soo; Bak, Young-Tae

    2006-09-28

    Foreign bodies in the upper esophagus should be removed as soon as possible to avoid serious complications. However, removals of foreign bodies in the upper esophagus are very difficult, especially if they have sharp edges, such as press-through-packs (PTPs). We experienced four cases of the impacted PTPs in the upper esophagus which was successfully extracted endoscopically with the overtube. Because two edges of PTPs were so firmly impacted in the esophageal wall in all cases, the PTPs were not movable in the upper esophagus. However, after insertion of the overtube, PTPs became movable and were successfully extracted and no serious complications occurred after extraction of PTPs. In one case, insertion of the overtube rapidly expanded the upper esophagus and PTP progressed to the gastric cavity and it could be extracted with the endoscopic protector hood. The endoscopic removal with the overtube was a simple, safe and effective technique for the removal of the impacted PTPs in upper esophagus.

  4. Removal of press-through-packs impacted in the upper esophagus using an overtube

    PubMed Central

    Seo, Yeon Seok; Park, Jong-Jae; Kim, Ji Hoon; Kim, Jin Yong; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2006-01-01

    Foreign bodies in the upper esophagus should be removed as soon as possible to avoid serious complications. However, removals of foreign bodies in the upper esophagus are very difficult, especially if they have sharp edges, such as press-through-packs (PTPs). We experienced four cases of the impacted PTPs in the upper esophagus which was successfully extracted endoscopically with the overtube. Because two edges of PTPs were so firmly impacted in the esophageal wall in all cases, the PTPs were not movable in the upper esophagus. However, after insertion of the overtube, PTPs became movable and were successfully extracted and no serious complications occurred after extraction of PTPs. In one case, insertion of the overtube rapidly expanded the upper esophagus and PTP progressed to the gastric cavity and it could be extracted with the endoscopic protector hood. The endoscopic removal with the overtube was a simple, safe and effective technique for the removal of the impacted PTPs in upper esophagus. PMID:17007065

  5. Upper gastrointestinal endoscopic and histologic findings before and after vertical banded gastroplasty.

    PubMed

    Papavramidis, S T; Theocharidis, A J; Zaraboukas, T G; Christoforidou, B P; Kessissoglou, I I; Aidonopoulos, A P

    1996-08-01

    A total of 30 consecutive morbidly obese patients, six males and 24 females, who underwent vertical banded gastroplasty (VBG) between January 1992 and December 1994 and were followed up by endoscopy and biopsy were included in this study with the aim to determine the short- and mid-term complications and to investigate alterations in esophageal, gastric, and duodenal mucosa after surgery. All patients underwent endoscopy before operation. Postoperatively, 28 patients were reendoscoped at 6 months, 26 at 12 months, and 22 at 18 months. Biopsies were taken from the lower part of esophagus, just below the esophagogastric junction (vertical part of the partitioned stomach), corpus, antrum, and duodenal bulb. Before operation 5 patients (16.6%) had a hiatus hernia and four of them (13.3%) had esophagitis. Endoscopic gastritis was diagnosed in nine patients (30%) and endoscopic duodenitis in two (6. 6%). Histologically, in 15 patients (50%) esophagitis was recognized; in 24 patients (80%) corpus gastritis; in 27 patients (90%) antral gastritis; and in 23 (76.6%) duodenitis. Helicobacter pylori was found in 20 (66.6%) patients. Postoperatively, three patients developed a mild stoma stenosis and were treated only by passing the endoscope 6 months after operation; one patient, with a severe stoma stenosis, was treated by Eder-Puestow dilatations and surgery. Gastric ulcer was found in two patients 6 and 12 months after surgery. One patient developed an endostomach channel because of staple line dehiscence 18 months after VBG. An increasing incidence of esophagitis and gastritis of the vertical part of the stomach was found at 6 and 12 months. Endoscopic and histologic gastritis of the corpus and antrum, as well as endoscopic and histologic duodenitis decreased gradually after surgery. Our findings suggest that postoperative complications of VBG can be diagnosed by endoscopy, and some of them can easily be managed. Vertical banded gastroplasty causes not only no harm to the

  6. Endoscopic Ultrasound of the Upper Gastrointestinal Tract and Mediastinum: Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prasad, Priyajit; Wittmann, Johannes; Pereira, Stephen P.

    2006-12-15

    Endoscopic ultrasound (EUS) has developed significantly over the last two decades and has had a considerable impact on the imaging and staging of mass lesions within or in close proximity to the gastrointestinal (GI) tract. In conjunction with conventional imaging such as helical computed tomography and magnetic resonance imaging, the indications for EUS include (1) differentiating between benign and malignant lesions of the mediastinum and upper GI tract, (2) staging malignant tumors of the lung, esophagus, stomach, and pancreas prior to surgery or oncological treatment, (3) excluding common bile duct stones before laparoscopic cholecystectomy, thereby avoiding the need for endoscopicmore » retrograde cholangiopancreatography (ERCP) in some patients, and (4) assessing suspected lesions that are either equivocal or not seen on conventional imaging. In recent years, EUS has charted a course similar to that taken by ERCP, evolving from a purely diagnostic modality to one that is interventional and therapeutic. These indications include (5) obtaining a tissue diagnosis by EUS-guided fine-needle aspiration or trucut-type needle biopsy and (6) providing therapy such as coeliac plexus neurolysis and pancreatic pseudocyst drainage-in many cases, more accurately and safely than conventional techniques. Emerging investigational techniques include EUS-guided enteric anastomosis formation and fine-needle injection therapy for malignant disease.« less

  7. Potential capacity of endoscopic screening for gastric cancer in Japan.

    PubMed

    Hamashima, Chisato; Goto, Rei

    2017-01-01

    In 2016, the Japanese government decided to introduce endoscopic screening for gastric cancer as a national program. To provide endoscopic screening nationwide, we estimated the proportion of increase in the number of endoscopic examinations with the introduction of endoscopic screening, based on a national survey. The total number of endoscopic examinations has increased, particularly in clinics. Based on the national survey, the total number of participants in gastric cancer screening was 3 784 967. If 30% of the participants are switched from radiographic screening to endoscopic screening, approximately 1 million additional endoscopic examinations are needed. In Japan, the participation rates in gastric cancer screening and the number of hospitals and clinics offering upper gastrointestinal endoscopy vary among the 47 prefectures. If the participation rates are high and the numbers of hospitals and clinics are small, the proportion of increase becomes larger. Based on the same assumption, 50% of big cities can provide endoscopic screening with a 5% increase in the total number of endoscopic examinations. However, 16.7% of the medical districts are available for endoscopic screening within a 5% increase in the total number of endoscopic examinations. Despite the Japanese government's decision to introduce endoscopic screening for gastric cancer nationwide, its immediate introduction remains difficult because of insufficient medical resources in rural areas. This implies that endoscopic screening will be initially introduced to big cities. To promote endoscopic screening for gastric cancer nationwide, the disparity of medical resources must first be resolved. © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  8. Endoscopic management of acute peptic ulcer bleeding.

    PubMed

    Lu, Yidan; Chen, Yen-I; Barkun, Alan

    2014-12-01

    This review discusses the indications, technical aspects, and comparative effectiveness of the endoscopic treatment of upper gastrointestinal bleeding caused by peptic ulcer. Pre-endoscopic considerations, such as the use of prokinetics and timing of endoscopy, are reviewed. In addition, this article examines aspects of postendoscopic care such as the effectiveness, dosing, and duration of postendoscopic proton-pump inhibitors, Helicobacter pylori testing, and benefits of treatment in terms of preventing rebleeding; and the use of nonsteroidal anti-inflammatory drugs, antiplatelet agents, and oral anticoagulants, including direct thrombin and Xa inhibitors, following acute peptic ulcer bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. [Endoscopic bouginage of benign esophageal and cardial strictures].

    PubMed

    Wierzbicki, J; Błaszczuk, J; Czapla, L; Adamus, A

    1997-01-01

    Endoscopic bouginage of benign esophageal and cardial strictures was compared with surgical treatment. Bouginage was performed by Celestin or Eder-Puestow bougies. Results obtained suggest usefulness of bouginage in many patients with benign stenosis of the upper gastrointestinal tract.

  10. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  11. Use of a real-time viewer for endoscopic deployment of capsule endoscope in the pediatric population.

    PubMed

    Bass, Lee M; Misiewicz, Lawrence

    2012-11-01

    Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.

  12. Endoscopic low-coherence topography measurement for upper airways and hollow samples

    NASA Astrophysics Data System (ADS)

    Delacrétaz, Yves; Shaffer, Etienne; Pavillon, Nicolas; Kühn, Jonas; Lang, Florian; Depeursinge, Christian

    2010-11-01

    To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.

  13. Congenital duodenal web: successful management with endoscopic dilatation

    PubMed Central

    Poddar, Ujjal; Jain, Vikas; Yachha, Surender Kumar; Srivastava, Anshu

    2016-01-01

    Background and study aims: Congenital duodenal web (CDW) is an uncommon cause of duodenal obstruction and endoscopic balloon dilatation has been reported in just eight pediatric cases to date. Here we are reporting three cases of CDW managed successfully with balloon dilatation. Cases and methods: In 2014 we diagnosed three cases of CDW on the basis of typical radiological and endoscopic findings. Endoscopic balloon dilatation was done under conscious sedation with a through-the-scope controlled radial expansion (CRE) balloon. Results: All three children presented late (median age 8 [range 2 – 9] years) with bilious vomiting, upper abdominal distension, and failure to thrive. One of them had associated Down syndrome and another had horseshoe kidney. In all cases, CDW was observed in the second part of the duodenum beyond the ampulla, causing partial duodenal obstruction. After repeated endoscopic dilatation (2 – 4 sessions), all three patients became asymptomatic. None of the patients experienced complications after balloon dilatation. Conclusions: Duodenal diaphragm should be suspected in patients with abdominal distension with bilious vomiting, even in relatively older children. Endoscopic balloon dilatation is a simple and effective method of treating this condition. PMID:27004237

  14. Current trends and pitfalls in endoscopic treatment of urolithiasis.

    PubMed

    Inoue, Takaaki; Okada, Shinsuke; Hamamoto, Shuzo; Yoshida, Takashi; Matsuda, Tadashi

    2018-02-01

    Current development of endoscopic technology, lithotripters, and stone-retrieval devices has expanded the indications for retrograde and antegrade endoscopic therapy in the management of urolithiasis. This technology has also resulted in minimally invasive therapy. As surgeons' experience of endourological procedures with the newer instruments has become integrated, the surgical technique and indications for urolithiasis have also changed in the past few years. The present review provides an overview of endourological procedures for upper urinary tract stones and the key points related to surgical techniques. © 2017 The Japanese Urological Association.

  15. A Review of Endoscopic Simulation: Current Evidence on Simulators and Curricula.

    PubMed

    King, Neil; Kunac, Anastasia; Merchant, Aziz M

    2016-01-01

    Upper and lower endoscopy is an important tool that is being utilized more frequently by general surgeons. Training in therapeutic endoscopic techniques has become a mandatory requirement for general surgery residency programs in the United States. The Fundamentals of Endoscopic Surgery has been developed to train and assess competency in these advanced techniques. Simulation has been shown to increase the skill and learning curve of trainees in other surgical disciplines. Several types of endoscopy simulators are commercially available; mechanical trainers, animal based, and virtual reality or computer-based simulators all have their benefits and limitations. However they have all been shown to improve trainee's endoscopic skills. Endoscopic simulators will play a critical role as part of a comprehensive curriculum designed to train the next generation of surgeons. We reviewed recent literature related to the various types of endoscopic simulators and their use in an educational curriculum, and discuss the relevant findings. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Hemospray for treatment of acute bleeding due to upper gastrointestinal tumours.

    PubMed

    Arena, Monica; Masci, Enzo; Eusebi, Leonardo Henry; Iabichino, Giuseppe; Mangiavillano, Benedetto; Viaggi, Paolo; Morandi, Elisabetta; Fanti, Lorella; Granata, Antonino; Traina, Mario; Testoni, Pier Alberto; Opocher, Enrico; Luigiano, Carmelo

    2017-05-01

    Hemospray is a new endoscopic haemostatic powder that can be used in the management of upper gastrointestinal bleedings. To assess the efficacy and safety of Hemospray as monotherapy for the treatment of acute upper gastrointestinal bleeding due to cancer. The endoscopy databases of 3 Italian Endoscopic Units were reviewed retrospectively and 15 patients (8 males; mean age 74 years) were included in this study. Immediate haemostasis was achieved in 93% of cases. Among the successful cases, 3 re-bled, one case treated with Hemospray and injection had a good outcome, while 2 cases died both re-treated with Hemospray, injection and thermal therapy. No complications related to Hemospray occurred. Finally, 80% of patients had a good clinical outcome at 30days and 50% at six months. Hemospray may be considered an effective and safe method for the endoscopic management of acute neoplastic upper gastrointestinal bleedings. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. A simplified clinical risk score predicts the need for early endoscopy in non-variceal upper gastrointestinal bleeding.

    PubMed

    Tammaro, Leonardo; Buda, Andrea; Di Paolo, Maria Carla; Zullo, Angelo; Hassan, Cesare; Riccio, Elisabetta; Vassallo, Roberto; Caserta, Luigi; Anderloni, Andrea; Natali, Alessandro

    2014-09-01

    Pre-endoscopic triage of patients who require an early upper endoscopy can improve management of patients with non-variceal upper gastrointestinal bleeding. To validate a new simplified clinical score (T-score) to assess the need of an early upper endoscopy in non variceal bleeding patients. Secondary outcomes were re-bleeding rate, 30-day bleeding-related mortality. In this prospective, multicentre study patients with bleeding who underwent upper endoscopy were enrolled. The accuracy for high risk endoscopic stigmata of the T-score was compared with that of the Glasgow Blatchford risk score. Overall, 602 patients underwent early upper endoscopy, and 472 presented with non-variceal bleeding. High risk endoscopic stigmata were detected in 145 (30.7%) cases. T-score sensitivity and specificity for high risk endoscopic stigmata and bleeding-related mortality was 96% and 30%, and 80% and 71%, respectively. No statistically difference in predicting high risk endoscopic stigmata between T-score and Glasgow Blatchford risk score was observed (ROC curve: 0.72 vs. 0.69, p=0.11). The two scores were also similar in predicting re-bleeding (ROC curve: 0.64 vs. 0.63, p=0.4) and 30-day bleeding-related mortality (ROC curve: 0.78 vs. 0.76, p=0.3). The T-score appeared to predict high risk endoscopic stigmata, re-bleeding and mortality with similar accuracy to Glasgow Blatchford risk score. Such a score may be helpful for the prediction of high-risk patients who need a very early therapeutic endoscopy. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Emergency endoscopic management of dietary foreign bodies in the esophagus.

    PubMed

    Lin, Hsuan-Hwai; Lee, Shih-Chun; Chu, Heng-Cheng; Chang, Wei-Kuo; Chao, You-Chen; Hsieh, Tsai-Yuan

    2007-07-01

    We report our experience of endoscopy in the emergency management of dietary foreign bodies. One hundred thirty-six patients were admitted to the emergency department (ED) between January 1997 and October 2006 for the endoscopic removal of esophageal dietary foreign bodies. They had a mean age of 47.7 years, and 91 (67%) were women. Most of the ingested materials (98.5%) were successfully extracted using either flexible or rigid endoscope. The objects most frequently ingested were fish bones (48%) and chicken bones (46%). Most of the objects (84%) were lodged in the upper esophagus. Two patients with irretrievable foreign bodies or complicated perforations were taken to surgery. Because most of these foreign bodies lodged in the upper esophagus, physicians should take care of this area to avoid secondary injury or complications, especially with sharp bones.

  19. Upper gastrointestinal bleeding - state of the art.

    PubMed

    Szura, Mirosław; Pasternak, Artur

    2014-01-01

    Upper gastrointestinal (GI) bleeding is a condition requiring immediate medical intervention, with high associated mortality exceeding 10%. The most common cause of upper GI bleeding is peptic ulcer disease, which largely corresponds to the intake of NSAIDs and Helicobacter pylori infection. Endoscopy is the essential tool for the diagnosis and treatment of active upper GI hemorrhage. Endoscopic therapy together with proton pump inhibitors and eradication of Helicobacter pylori significantly reduces rebleeding rates, mortality and number of emergency surgical interventions. This paper presents contemporary data on the diagnosis and treatment of upper gastrointestinal bleeding.

  20. Upper Nasopharyngeal Corridor for Transnasal Endoscopic Drainage of Petroclival Cholesterol Granulomas: Alternative Access in Conchal Sphenoid Patients.

    PubMed

    Turan, Nefize; Baum, Griffin R; Holland, Christopher M; Ahmad, Faiz U; Henriquez, Oswaldo A; Pradilla, Gustavo

    2016-03-01

    Background Cholesterol granulomas arising at the petrous apex can be treated via traditional open surgical, endoscopic, and endoscopic-assisted approaches. Endoscopic approaches require access to the sphenoid sinus, which is technically challenging in patients with conchal sphenoidal anatomy. Clinical Presentation A 55-year-old woman presented with intermittent headaches and tinnitus. Formal audiometry demonstrated moderately severe bilateral hearing loss. CT of the temporal bones and sella revealed a well-demarcated expansile lytic mass. MRI of the face, orbit, and neck showed a right petrous apex mass measuring 22 × 18 × 19 mm that was hyperintense on T1- and T2-weighted images without enhancement, consistent with a cholesterol granuloma. The patient had a conchal sphenoidal anatomy. Operative Technique Herein, we present an illustrative case of a low-lying petroclival cholesterol granuloma in a patient with conchal sphenoidal anatomy to describe an alternative high nasopharyngeal corridor for endoscopic transnasal transclival access. Postoperative Course Postoperatively, the patient's symptoms recovered and no complications occurred. Follow-up imaging demonstrated a patent drainage tract without evidence of recurrence. Conclusion In patients with a conchal sphenoid sinus, endoscopic transnasal transclival access can be gained using a high nasopharyngeal approach. This corridor facilitates safe access to these lesions and others in this location.

  1. Current status of colonic endoscopic mucosal resection in the west and the interface with endoscopic submucosal dissection.

    PubMed

    Bourke, Michael

    2009-07-01

    Endoscopic Mucosal Resection (EMR) is now widely practised by western endoscopists to treat large sessile colonic polyps or laterally spreading tumours. Despite its widespread application, the technique of colonic EMR is not standardised. A lesion specific endoscopic treatment approach is also lacking. For lesions larger than 25mm, EMR is limited by its inability to achieve en-bloc resection. En-bloc resection has many theoretical advantages including more accurate histological assessment, reduced recurrence and potentially curative treatment for low risk submucosal invasive neoplasia particularly in patients with significant co-morbidity. Hence, Japanese endoscopists, having pioneered endoscopic submucosal dissection (ESD) in the upper gastrointestinal tract for the en-bloc resection of superficial neoplasia, now advocate the use of ESD for laterally spreading tumours of the colon greater than 25-30mm. This treatment strategy is not widely accepted or practised in the west and has its own inherent problems. The absence of suitable gastric lesions on which to develop ESD skills is also another significant barrier to the development of colonic ESD. It is also possible that modification and refinement in EMR technique may increase the size limit for colonic EMR.

  2. Bleeding and starving: fasting and delayed refeeding after upper gastrointestinal bleeding.

    PubMed

    Fonseca, Jorge; Meira, Tânia; Nunes, Ana; Santos, Carla Adriana

    2014-01-01

    Early refeeding after nonvariceal upper gastrointestinal bleeding is safe and reduces hospital stay/costs. The aim of this study was obtaining objective data on refeeding after nonvariceal upper gastrointestinal bleeding. From 1 year span records of nonvariceal upper gastrointestinal bleeding patients that underwent urgent endoscopy: clinical features; rockall score; endoscopic data, including severity of lesions and therapy; feeding related records of seven days: liquid diet prescription, first liquid intake, soft/solid diet prescription, first soft/solid intake. From 133 patients (84 men) Rockall classification was possible in 126: 76 score ≥5, 50 score <5. One persistent bleeding, eight rebled, two underwent surgery, 13 died. Ulcer was the major bleeding cause, 63 patients underwent endoscopic therapy. There was 142/532 possible refeeding records, no record 37% patients. Only 16% were fed during the first day and half were only fed on third day or later. Rockall <5 patients started oral diet sooner than Rockall ≥5. Patients that underwent endoscopic therapy were refed earlier than those without endotherapy. Most feeding records are missing. Data reveals delayed refeeding, especially in patients with low-risk lesions who should have been fed immediately. Nonvariceal upper gastrointestinal bleeding patients must be refed earlier, according to guidelines.

  3. [Endoscopic treatment of gastroduodenal digestive hemorrhage].

    PubMed

    Llanos, J; Valdés, E; Cofré, C; Tapia, A; Denegri, E

    1992-12-01

    Endoscopy is extremely useful for the diagnosis of upper gastrointestinal bleeding. At the present time, therapeutic measures are been used during the endoscopy to stop bleeding. This paper reports the experience of hospital de Talca in the endoscopic treatment of upper gastrointestinal bleeding. Thirty four patients (22 male) with bleeding not originating from esophageal or gastric varices were treated with direct absolute alcohol injection into the bleeding lesions. The procedure was successful in 31 patients. Three of the 34 patients required surgery, but only one of those successfully sclerosed (97% success). There were no complications attributable to the procedure. It is concluded that this therapeutic modality must be implemented in places were gastrointestinal endoscopy is performed.

  4. High-quality endoscope reprocessing decreases endoscope contamination.

    PubMed

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  5. Exercising upper respiratory videoendoscopic evaluation of 100 nonracing performance horses with abnormal respiratory noise and/or poor performance.

    PubMed

    Davidson, E J; Martin, B B; Boston, R C; Parente, E J

    2011-01-01

    Although well documented in racehorses, there is paucity in the literature regarding the prevalence of dynamic upper airway abnormalities in nonracing performance horses. To describe upper airway function of nonracing performance horses with abnormal respiratory noise and/or poor performance via exercising upper airway videoendoscopy. Medical records of nonracing performance horses admitted for exercising evaluation with a chief complaint of abnormal respiratory noise and/or poor performance were reviewed. All horses had video recordings of resting and exercising upper airway endoscopy. Relationships between horse demographics, resting endoscopic findings, treadmill intensity and implementation of head and neck flexion during exercise with exercising endoscopic findings were examined. Dynamic upper airway obstructions were observed in 72% of examinations. Head and neck flexion was necessary to obtain a diagnosis in 21 horses. Pharyngeal wall collapse was the most prevalent upper airway abnormality, observed in 31% of the examinations. Complex abnormalities were noted in 27% of the examinations. Resting laryngeal dysfunction was significantly associated with dynamic arytenoid collapse and the odds of detecting intermittent dorsal displacement of the soft palate (DDSP) during exercise in horses with resting DDSP was only 7.7%. Exercising endoscopic observations were different from the resting observations in 54% of examinations. Dynamic upper airway obstructions were common in nonracing performance horses with respiratory noise and/or poor performance. Resting endoscopy was only helpful in determining exercising abnormalities with recurrent laryngeal neuropathy. This study emphasises the importance of exercising endoscopic evaluation in nonracing performance horses with abnormal respiratory noise and/or poor performance for accurate assessment of dynamic upper airway function. © 2010 EVJ Ltd.

  6. Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan

    2017-01-01

    The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.

  7. Reality named endoscopic ultrasound biliary drainage

    PubMed Central

    Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida

    2015-01-01

    Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507

  8. Animal feasibility study of an innovated splash-needle for endoscopic submucosal dissection in the upper gastrointestinal tract.

    PubMed

    Fujishiro, Mitsuhiro; Sugita, Noriyuki

    2013-01-01

    The high frequency of complications accompanying endoscopic submucosal dissection (ESD) and its complex processes suggest that the process requires improvement. The objective of the present study was to investigate the feasibility of an innovated splash-needle for ESD. An animal feasibility study with a living pig was conducted. Six resections per portion (esophagus and upper, middle, and lower thirds of the stomach) in a total of 24 resections were carried out by using an original splash-needle or an innovated splash-needle. Major innovations were a thicker part in the middle of the knife and a metal plate on the tip of the sheath to obtain more coagulation ability. Injection solution in the submucosal layer was also changed due to possible influence on the outcomes. Main outcome measurements were entire procedure time, cutting speed, and frequency of bleeding during ESD. All the 24 resections were completed without complications. Among the obtained data, only mean cutting speeds were significantly influenced by location of the simulated lesion, which revealed that ESD at the upper third was significantly quicker than that at the lower third (P = 0.01), and ESD at the esophagus was significantly slower than that at the three parts of the stomach (P < 0.01). There was no significant difference between the different knives in each variable. The innovated splash-needle will be feasible for human use, although the safety and advantages in clinical settings must be elucidated by proper comparative studies with existing knives in humans. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  9. [Comparison on Endoscopic Hemoclip and Hemoclip Combination Therapy in Non-variceal Upper Gastrointestinal Bleeding Patients Based on Clinical Practice Data: Is There Difference between Prospective Cohort Study and Randomized Study?].

    PubMed

    Lee, Su Hyun; Jung, Jin Tae; Lee, Dong Wook; Ha, Chang Yoon; Park, Kyung Sik; Lee, Si Hyung; Yang, Chang Heon; Park, Youn Sun; Jeon, Seong Woo

    2015-08-01

    Endoscopic hemoclip application is an effective and safe method of endoscopic hemostasis. We conducted a multicenter retrospective study on hemoclip and hemoclip combination therapy based on prospective cohort database in terms of hemostatic efficacy not in clinical trial but in real clinical practice. Data on endoscopic hemostasis for non-variceal upper gastrointestinal bleeding (NVUGIB) were prospectively collected from February 2011 to December 2013. Among 1,584 patients with NVUGIB, 186 patients treated with hemoclip were enrolled in this study. Subjects were divided into three groups: Group 1 (n = 62), hemoclipping only; group 2 (n = 88), hemoclipping plus epinephrine injection; and group 3 (n = 36), hemocliping and epinephrine injection plus other endoscopic hemostatic modalities. Primary outcomes included rebleeding, other therapeutic management, hospitalization period, fasting period and mortality. Secondary outcomes were bleeding associated mortality and overall mortality. Active bleeding and peptic ulcer bleeding were more common in group 3 than in group 1 and in group 2 (p <œ 0.001). However, primary outcomes (rebleeding, other management, morbidity, hospitalization period, fasting period and mortality) and secondary outcomes (bleeding associated mortality and total mortality) were not different among groups. Combination therapy of epinephrine injection and other modalities with hemoclips did not show advantage over hemoclipping alone in this prospective cohort study. However, there is a tendency to perform combination therapy in active bleeding which resulted in equivalent hemostatic success rate, and this reflects the role of combination therapy in clinical practice.

  10. From an urologist view: are we safe with endoscopic surgery? Overview of ergonomic problems encountered by the urologist during video endoscopic surgery.

    PubMed

    Sataa, Sallami; Benzarti, Aida; Ben Jemaa, Abdelmajid

    2012-12-01

    The importance of minimally invasive surgery in urology has constantly increased in the last 20 years. Endoscopic resection of prostate and bladder tumors is actually a gold standard with many advantages for patients. To analyze the problems related to the ergonomic conditions faced by urologist during video endoscopic surgery by review of the recent literature. All evidence-based experimental ergonomic studies conducted in the fields of urology endoscopic surgery and applied ergonomics for other professions working with a display were identified by PubMed searches. Data from ergonomic studies were evaluated in terms of efficiency as well as comfort and safety aspects. Constraint postures for urologists are described and ergonomic requirements for optimal positions are discussed. The ergonomics of urological endoscopic surgery place urologists at risk for potential injury. The amount of neck flexion or extension, the amount of shoulder girdle adduction or abduction used, and stability of the upper extremities during surgery; which are maintained in a prolonged static posture; are the main risk factors. All these constraints may lead to muscle and joint fatigue, pain, and eventual musculoskeletal injury. Moreover, these issues may impact surgical accuracy. Urologist posture, operating period, training are important ergonomic factor during video surgery to prevent musculoskeletal disorders.

  11. Medical and endoscopic treatment in peptic ulcer bleeding: a national German survey.

    PubMed

    Maiss, J; Schwab, D; Ludwig, A; Naegel, A; Ende, A; Hahn, G; Zopf, Y

    2010-02-01

    Peptic ulcers are the leading cause of upper gastrointestinal (GI) bleeding. The aim of this study was the evaluation of the recent clinical practice in drug therapy and endoscopic treatment of ulcer bleedings in Germany and to compare the results with the medical standard. A structured questionnaire (cross-sectional study) was sent to 1371 German hospitals that provide an emergency service for upper GI bleeding. The project was designed similar to a nationwide inquiry in France in 2001. Forty-four questions concerning the following topics were asked: hospital organisation, organisation of emergency endoscopy service, endoscopic and drug therapy of ulcer bleeding, endoscopic treatment of variceal bleeding. Return of the questionnaires was closed in August 2004. Response rate was 675 / 1371 (49 %). Mean hospitals size was < 200 beds, 49 % (n = 325) had basic care level. 92 % provided a 24-hour endoscopy service, specialized nurses were available in 75 %. Fiberscopes were used only in 15 %. A mean of 10 +/- 12 (range: 0 - 160) bleeding cases/month were treated, 6 +/- 6 cases per month (60 %) were ulcer bleedings. Endoscopy was performed in 72 % immediately after stabilization but in all cases within 24 hours. The Forrest classification was used in 99 % whereas prognostic scores were applied only in 3 %. Forrest Ia,/Ib/IIa/IIb/IIc/III ulcers were indications for endoscopic therapy in 99 %/ 99 %/ 90 %/ 58 %/ 4 %/ 2 % respectively. Favoured initial treatment was injection (diluted epinephrine, mean volume 17 +/- 13 mL/lesion) followed by clipping. In re-bleedings, 93 % tried endoscopic treatment again. Scheduled re-endoscopy was performed in 63 %. PPI were used in 99.6 %, 85 % administered standard dose twice daily. PPI administration was changed from intravenous to oral with the end of fasting in nearly all hospitals. PPI administration schemes can be improved. Indications for Helicobacter pylori eradication followed rational principles. Medical and endoscopic

  12. Orbital endoscopic surgery

    PubMed Central

    Selva, Dinesh

    2008-01-01

    Minimally invasive ″keyhole″ surgery performed using endoscopic visualization is increasing in popularity and is being used by almost all surgical subspecialties. Within ophthalmology, however, endoscopic surgery is not commonly performed and there is little literature on the use of the endoscope in orbital surgery. Transorbital use of the endoscope can greatly aid in visualizing orbital roof lesions and minimizing the need for bone removal. The endoscope is also useful during decompression procedures and as a teaching aid to train orbital surgeons. In this article, we review the history of endoscopic orbital surgery and provide an overview of the technique and describe situations where the endoscope can act as a useful adjunct to orbital surgery. PMID:18158397

  13. Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review.

    PubMed

    East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc

    2016-11-01

    Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Early experience with high-flow nasal oxygen therapy (HFNOT) in pediatric endoscopic airway surgery.

    PubMed

    Riva, Thomas; Theiler, Lorenz; Jaquet, Yves; Giger, Roland; Nisa, Lluís

    2018-05-01

    Reporting our institutional experience with high-flow nasal oxygen therapy (HFNOT), a recently-introduced technique, for endoscopic airway approaches. Prospective collection of data of children (<16 years) undergoing endoscopic between January 2016 and August 2017 at a tertiary referral university hospital. HFNOT was used in 6 children who underwent 14 procedures for different forms and causes of upper airway obstruction of various origins. No intraoperative complications; related to oxygenation were observed, and the surgical procedures could be carried out as; initially planned. We found that HFNOT is an effective and safe technique with a variety of potential applications in the field of endoscopic pediatric airway surgery. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Upper gastrointestinal ectopic variceal bleeding treated with various endoscopic modalities: Case reports and literature review.

    PubMed

    Park, Sang Woo; Cho, Eunae; Jun, Chung Hwan; Choi, Sung Kyu; Kim, Hyun Soo; Park, Chang Hwan; Rew, Jong Sun; Cho, Sung Bum; Kim, Hee Joon; Han, Mingui; Cho, Kyu Man

    2017-01-01

    Ectopic variceal bleeding is a rare (2-5%) but fatal gastrointestinal bleed in patients with portal hypertension. Patients with ectopic variceal bleeding manifest melena, hematochezia, or hematemesis, which require urgent managements. Definitive therapeutic modalities of ectopic varices are not yet standardized because of low incidence. Various therapeutic modalities have been applied on the basis of the experiences of experts or availability of facilities, with varying results. We have encountered eight cases of gastrointestinal ectopic variceal bleeding in five patients in the last five years. All patients were diagnosed with liver cirrhosis presenting melena or hematemesis. All patients were treated with various endoscopic modalities (endoscopic variceal obturation [EVO] with cyanoacrylate in five cases, endoscopic variceal band ligation (EVL) in two cases, hemoclipping in one case). Satisfactory hemostasis was achieved without radiologic interventions in all cases. EVO and EVL each caused one case of portal biliopathy, and EVL induced ulcer bleeding in one case. EVO generally accomplished better results of variceal obturations than EVL or hemoclipping, without serious adverse events. EVO may be an effective modality for control of ectopic variceal bleeding without radiologic intervention or surgery.

  16. Endoscopic therapy in early adenocarcinomas (Barrett's cancer) of the esophagus.

    PubMed

    Knabe, Mate; May, Andrea; Ell, Christian

    2015-07-01

    The incidence of early esophageal adenocarcinoma has been increasing significantly in recent decades. Prognosis depends greatly on the choice of treatment. Early cancers can be treated by endoscopic resection, whereas advanced carcinomas have to be sent for surgery. Esophageal resection is associated with high perioperative mortality (1-5%) even in specialized centers. Early diagnosis enables curative endoscopic treatment option. Patients with gastrointestinal symptoms and a familial risk for esophageal cancer should undergo upper gastrointestinal endoscopy. High-definition endoscopes have been developed with technical add-on that helps endoscopists to find fine irregularities in the esophageal mucosa, but interpreting the findings remains challenging. In this review we discussed novel and old diagnostic procedures and their values, as well as our own recommendations and those of the authors discussed for the diagnosis and treatment of early Barrett's carcinoma. Endoscopic resection is the therapy of choice in early esophageal adenocarcinoma. It is mandatory to perform a subsequent ablation of all residual Barrett's mucosa to avoid metachronous lesions. © 2015 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  17. Endoscopic Skipping of the Terminal Ileum in Pediatric Crohn Disease.

    PubMed

    Mansuri, Ishrat; Fletcher, Joel G; Bruining, David H; Kolbe, Amy B; Fidler, Jeff L; Samuel, Sunil; Tung, Jeanne

    2017-06-01

    Pediatric small-bowel (SB) Crohn disease (CD) may be missed if the terminal ileum (TI) appears normal at endoscopy and SB imaging is not performed. We sought to estimate the prevalence and clinical characteristics of pediatric patients with CD and endoscopic skipping of the TI-that is, pediatric patients with active SB or upper gut inflammation and an endoscopically normal TI. This retrospective study included pediatric patients with CD who underwent both CT enterography (CTE) or MR enterography (MRE) and ileocolonoscopy within a 30-day period between July 2004 and April 2014. The physician global assessment was used as the reference standard for SB CD activity. Radiologists reviewed the CTE and MRE studies for inflammatory parameters; severity, length, and multifocality of SB inflammation; and the presence of penetrating complications. Of 170 patients who underwent ileal intubation, the TI was macroscopically normal or showed nonspecific inflammation in 73 patients (43%). Nearly half (36/73, 49%) of the patients with normal or nonspecific findings at ileocolonoscopy had radiologically active disease with a median length of SB involvement of 20 cm (range, 1 to > 100 cm). Seventeen (47%) of these patients had multifocal SB involvement and five (14%) had penetrating complications. Overall, endoscopic TI skipping was present in 43 (59%) patients with normal or nonspecific ileocolonoscopic findings: 20 with histologic inflammation (17 with positive imaging findings), 14 with inflammation at imaging only, and nine with proximal disease (upper gut, jejunum, or proximal ileum). There were no significant differences in the clinical parameters of the patients with and those without endoscopic TI skipping. Ileocolonoscopy may miss SB CD in pediatric patients that is due to isolated histologic, intramural, or proximal inflammation. Enterography is complementary to ileocolonoscopy in the evaluation of pediatric CD.

  18. Endoscopic submucosal dissection for early gastric cancer on the lesser curvature in upper third of the stomach is a risk factor for postoperative delayed gastric emptying.

    PubMed

    Yoshizaki, Tetsuya; Obata, Daisuke; Aoki, Yasuhiro; Okamoto, Norihiro; Hashimura, Hiroki; Kano, Chise; Matsushita, Megumi; Kanamori, Atsushi; Matsumoto, Kei; Tsujimae, Masahiro; Momose, Kenji; Eguchi, Takaaki; Okuyama, Shunsuke; Yamashita, Hiroshi; Fujita, Mikio; Okada, Akihiko

    2018-02-07

    Advances in Endoscopic submucosal dissection (ESD) technology have established ESD for early gastric cancer as a safe and stable technique. However, ESD may induce delayed gastric emptying and the cause of food residue retention in the stomach after ESD is not clear. This study aimed to clarify risk factors for delayed gastric emptying with food retention after gastric ESD. We retrospectively examined for food residue in the stomach 1 week after ESD was performed for early gastric carcinoma at Osaka Saiseikai Nakatsu Hospital from February 2008 to November 2016. Food residue was observed in 68 (6.1%) of 1114 patients who underwent gastric ESD. The percentage of lesions located on the lesser curvature of the upper third of the stomach was 45.6% (31/68) in the food residue group and 3.5% (37/1046) in the non-food residue group, which was significantly different (P < 0.01). Multivariate logistic regression analysis revealed that lesions on the lesser curvature of the upper third of the stomach (Odds ratio [OR] 23.31, 95% confidence interval [CI] 12.60-43.61, P < 0.01), post-ESD bleeding (OR 4.25, 95%CI 1.67-9.80, P < 0.01), submucosal invasion (OR 2.80, 95%CI 1.34-5.63, P < 0.01), and age over 80 years (OR 2.34, 95%CI 1.28-4.22, P < 0.01) were independent risk factors for food retention after gastric ESD. Of the 68 patients, 3 had food residue in the stomach on endoscopic examination for follow-up observation after the ESD ulcer had healed. Delayed gastric emptying with food retention after gastric ESD was associated with lesions located in the lesser curvature of the upper stomach, submucosal invasion of the lesion, age older than 80 years, and post-ESD bleeding, though it was temporary in most cases.

  19. [Choledocholithiasis and pregnancy. Hybrid laparo-endoscopic treatment in one step].

    PubMed

    Valadez-Caballero, David; González-Santamaría, Roberto; Soto-Mendoza, Héctor; Alberto Blanco-Figueroa, Jorge; Flores-Pantoja, Juan Manuel

    2014-01-01

    Complications associated with choledocholithiasis are uncommon during pregnancy. However, when it occurs, the morbidity and mortality related for the product and the mother increases, so a proper treatment is imperative in these patients. A 25-year-old pregnant woman on her second trimester. The current condition was started four days prior to the hospital admission with abdominal pain in the right upper quadrant with nausea and vomit.Twenty-four hours later jaundice and dark urine is observed. Physical examination shows scleral jaundice, right upper quadrant abdominal pain without peritoneal irritation. Uterus at umbilicus level without uterine activity. Uterus at umbilicus level without uterine activity. Laboratory tests showed elevated bilirubin and transaminases without leukocytosis; ultrasound reported live intrauterine unique product, with a heart rate of 128 beats per minute, gallbladder with multiple images inside that cast acoustic shadowing, and a 10 mm common bile duct dilated bile duct with dilatation of intrahepatic bile ducts. It was perform laparoscopic cholecystectomy with intraoperative cholangiography and placement of a transcystic jaguar guide for selective cannulation of the common bile duct. Intraoperative endoscopic retrograde cholangiopancreatography was performed with endoscopic stone extraction. The outcome was satisfactory with a hospital discharge at 48 hours. Current evidence has shown that the combined use of laparoscopy and therapeutic endoscopic cholangiography in one step is effective for the treatment of choledocholithiasis, decreasing the risk of complications associated with cannulation of the bile duct.

  20. Leiomyosarcoma of the stomach treated by endoscopic submucosal dissection.

    PubMed

    Sato, Takao; Akahoshi, Kazuya; Tomoeda, Naru; Kinoshita, Norikatsu; Kubokawa, Masaru; Yodoe, Kentaro; Hiraki, Yuka; Oya, Masafumi; Yamamoto, Hidetaka; Ihara, Eikichi

    2018-03-02

    There have been no reports of primary leiomyosarcoma of the stomach treated by endoscopic submucosal dissection (ESD). We report an extremely rare case of gastric leiomyosarcoma that was successfully treated by ESD. An asymptomatic 74-year-old female underwent esophagogastroduodenoscopy for screening in December 2013. A centrally depressed submucosal tumor 10 mm in diameter was detected at the posterior wall of the upper gastric body. Follow-up esophagogastroduodenoscopy conducted 5 months later showed that the tumor diameter had increased to 15 mm. Endoscopic ultrasound revealed a hypoechoic mass located in the second to the middle of the third layer. Endoscopic ultrasound-guided fine-needle aspiration demonstrated a myogenic tumor. The tumor was completely resected by ESD without complications. Immunohistopathological diagnosis of the resected specimen was gastric leiomyosarcoma derived from the muscularis mucosae, with negative lateral and vertical margins. No local recurrence or metastasis has been detected at 36 months after ESD. This is the first report of gastric leiomyosarcoma treated by ESD in the English language literature.

  1. Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.

    PubMed

    Khan, Mubarak M; Parab, Sapna R

    2016-06-01

    The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.

  2. Automated high-level disinfection of nonchanneled flexible endoscopes: duty cycles and endoscope repair.

    PubMed

    Statham, Melissa McCarty; Willging, J Paul

    2010-10-01

    Guidelines issued by the Association of Operating Room Nurses and the Association of Professionals in Infection Control and Epidemiology recommend high-level disinfection (HLD) for semicritical instruments, such as flexible endoscopes. We aim to examine the durability of endoscopes to continued use and automated HLD. We report the number of duty cycles a flexible endoscope can withstand before repairs should be anticipated. Retrospective review. A total of 4,336 endoscopic exams and subsequent disinfection cycles were performed with 60 flexible endoscopes in an outpatient tertiary pediatric otolaryngology practice from 2005 to 2009. All endoscopes were systemically cleaned with mechanical cleansing followed by leak testing, enzymatic cleaning, and exposure to Orthophthaldehyde (0.55%) for 5 minutes at a temperature of at least 25°C, followed by rinsing for 3 minutes. A total of 77 repairs were performed, 48 major (average cost $3,815.97), and 29 minor (average cost $326.85). On average, the 2.2-mm flexible endoscopes were utilized for 61.9 examinations before major repair was needed, whereas the 3.6 mm endoscopes were utilized for 154.5 exams before needing minor repairs. No major repairs have been needed to date on the 3.6-mm endoscopes. Automated endoscope reprocessor use for HLD is an effective means to disinfect and process flexible endoscopes. This minimizes variability in the processing of the endoscopes and maximizes the rate of successful HLD. Even when utilizing standardized, automated HLD and limiting the number of personnel processing the endoscopes, smaller fiberoptic endoscopes demonstrate a shortened time interval between repairs than that seen with the larger endoscopes. Laryngoscope, 2010.

  3. Nutritional status improvement in neurologically impaired patients by percutaneous endoscopic gastrostomy feeding.

    PubMed

    Nakao, F S; Brant, C Q; Stanich, P; Ferrari Júnior, A P

    1999-01-01

    With increased use of percutaneous endoscopic gastrostomy, it became clear that neurologically impaired patients might benefit from its use. From August 1996 to July 1997, we performed 19 percutaneous endoscopic gastrostomies in patients with neurological sequelae, who were incapable to maintain their nutritional status by oral ingestion or had repeated episodes of aspiration. Sixteen patients were followed prospectively, from 30 days to 11 months (median: 6.4 months). Average weight (38.2 kg to 44.8 kg), BMI (14.8 kg/m2 to 17.8 kg/m2), weight/height ratio (23.5 kg/cm to 28 kg/cm), mid-upper arm circumference (19.4 cm to 21.6 cm) and triceps skinfold thickness (10.3 mm to 12.6 mm) were significantly increased (P < 0.01). Before percutaneous endoscopic gastrostomy, there were 10 (10/16, 62.5%) patients with grade III thinness. In this group, 3/10 patients (30%) showed improvement to grade I (two individuals) and II (one patient). All but five patients (68.75%) were below the fifth percentile of normal distribution for mid-upper arm circumference. One patient (6.2%) showed improvement of her status (between 25th and 50th percentiles). Four patients (25%) started the follow-up below the fifth percentile for normal distribution of triceps skinfold thickness, and showed no improvement. There were no early complications secondary the procedure. Late complications included granulation tissue on ostomy site (18.8%) and ostomy infection (6.2%). Statistical analysis showed significant improvement of anthropometric data. Percutaneous endoscopic gastrostomy is a simple, highly successful and safe procedure, when performed in neurologically impaired patients. It is efficient as a long-term enteral feeding method.

  4. Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.

    PubMed

    Hopf, N J

    1999-03-01

    Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).

  5. Splenic artery ligature associated with endoscopic banding for schistosomal portal hypertension.

    PubMed

    Colaneri, Renata Potonyacz; Coelho, Fabrício Ferreira; de Cleva, Roberto; Perini, Marcos Vinícius; Herman, Paulo

    2014-11-28

    To propose a less invasive surgical treatment for schistosomal portal hypertension. Ten consecutive patients with hepatosplenic schistosomiasis and portal hypertension with a history of upper gastrointestinal hemorrhage from esophageal varices rupture were evaluated in this study. Patients were subjected to a small supraumbilical laparotomy with the ligature of the splenic artery and left gastric vein. During the procedure, direct portal vein pressure before and after the ligatures was measured. Upper gastrointestinal endoscopy was performed at the 30(th) postoperative day, when esophageal varices diameter were measured and band ligature performed. During follow-up, other endoscopic procedures were performed according to endoscopy findings. There was no intra-operative mortality and all patients had confirmed histologic diagnoses of schistosomal portal hypertension. During the immediate postoperative period, two of the ten patients had complications, one characterized by a splenic infarction, and the other by an incision hematoma. Mean hospitalization time was 4.1 d (range: 2-7 d). Pre- and post-operative liver function tests did not show any significant changes. During endoscopy thirty days after surgery, a decrease in variceal diameters was observed in seven patients. During the follow-up period (57-72 mo), endoscopic therapy was performed and seven patients had their varices eradicated. Considering the late postoperative evaluation, nine patients had a decrease in variceal diameters. A mean of 3.9 endoscopic banding sessions were performed per patient. Two patients presented bleeding recurrence at the late postoperative period, which was controlled with endoscopic banding in one patient due to variceal rupture and presented as secondary to congestive gastropathy in the other patient. Both bleeding episodes were of minor degree with no hemodynamic consequences or need for blood transfusion. Ligature of the splenic artery and left gastric vein with supraumbilical

  6. Medical and Endoscopic Management of Gastric Varices

    PubMed Central

    Al-Osaimi, Abdullah M. S.; Caldwell, Stephen H.

    2011-01-01

    In the past 20 years, our understanding of the pathophysiology and management options among patients with gastric varices (GV) has changed significantly. GV are the most common cause of upper gastrointestinal bleeding in patients with portal hypertension after esophageal varices (EV) and generally have more severe bleeding than EV. In the United States, the majority of GV patients have underlying portal hypertension rather than splenic vein thrombosis. The widely used classifications are the Sarin Endoscopic Classification and the Japanese Vascular Classifications. The former is based on the endoscopic appearance and location of the varices, while the Japanese classification is based on the underlying vascular anatomy. In this article, the authors address the current concepts of classification, epidemiology, pathophysiology, and emerging management options of gastric varices. They describe the stepwise approach to patients with gastric varices, including the different available modalities, and the pearls, pitfalls, and stop-gap measures useful in managing patients with gastric variceal bleed. PMID:22942544

  7. Asia-Pacific working group consensus on non-variceal upper gastrointestinal bleeding: an update 2018.

    PubMed

    Sung, Joseph Jy; Chiu, Philip Cy; Chan, Francis K L; Lau, James Yw; Goh, Khean-Lee; Ho, Lawrence Hy; Jung, Hwoon-Young; Sollano, Jose D; Gotoda, Takuji; Reddy, Nageshwar; Singh, Rajvinder; Sugano, Kentaro; Wu, Kai-Chun; Wu, Chun-Yin; Bjorkman, David J; Jensen, Dennis M; Kuipers, Ernst J; Lanas, Angel

    2018-04-24

    Non-variceal upper gastrointestinal bleeding remains an important emergency condition, leading to significant morbidity and mortality. As endoscopic therapy is the 'gold standard' of management, treatment of these patients can be considered in three stages: pre-endoscopic treatment, endoscopic haemostasis and post-endoscopic management. Since publication of the Asia-Pacific consensus on non-variceal upper gastrointestinal bleeding (NVUGIB) 7 years ago, there have been significant advancements in the clinical management of patients in all three stages. These include pre-endoscopy risk stratification scores, blood and platelet transfusion, use of proton pump inhibitors; during endoscopy new haemostasis techniques (haemostatic powder spray and over-the-scope clips); and post-endoscopy management by second-look endoscopy and medication strategies. Emerging techniques, including capsule endoscopy and Doppler endoscopic probe in assessing adequacy of endoscopic therapy, and the pre-emptive use of angiographic embolisation, are attracting new attention. An emerging problem is the increasing use of dual antiplatelet agents and direct oral anticoagulants in patients with cardiac and cerebrovascular diseases. Guidelines on the discontinuation and then resumption of these agents in patients presenting with NVUGIB are very much needed. The Asia-Pacific Working Group examined recent evidence and recommends practical management guidelines in this updated consensus statement. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Efficacy of simethicone and N-acetylcysteine as premedication in improving visibility during upper endoscopy.

    PubMed

    Chang, Wei-Kuo; Yeh, Ming-Kung; Hsu, Hsuang-Chun; Chen, Hsuan-Wei; Hu, Ming-Kuan

    2014-04-01

    Simethicone and N-acetylcysteine have been widely used in improving endoscopic visibility. However, the optimal dose, volume, and dosing time for the premedication regimen are still unclear. Our aim was to assess the efficacy of premedication in improving endoscopic visibility and determine the contributions of dose, volume, and premedication time. A total of 1849 patients were prospectively treated in three groups: group A: 100-mg simethicone suspension in 5 mL water; group B: 100-mg simethicone suspension in 100 mL water; and group C: 100-mg simethicone suspension in 100 mL water containing 200 mg N-acetylcysteine. Mucosa visibility was assessed at seven sites of upper gastrointestinal tract. The sum of scores was considered as total mucosal visibility score (TMVS). The upper body of stomach had the worst visibility score for all groups. TMVS of groups B and C were significantly lower than those of group A. Group C had a significantly fewer patients requiring endoscopic flushing than groups A and B. The TMVS for groups B and C were significantly lower than for group A within 30 min of beginning premedication. Beyond 30 min of premedication, there was no significant difference in the TMVS among groups. Premedication using 100 mg simethicone in 100 mL of water improves endoscopic visibility. Addition of N-acetylcysteine to simethicone in 100 mL of water reduces the need for endoscopic flushing. For patients unable to tolerate a large fluid volume, a 5-mL simethicone suspension administered more than 30 min prior to upper endoscopy is suggested. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  9. Immediate Partial Breast Reconstruction with Endoscopic Latissimus Dorsi Muscle Flap Harvest

    PubMed Central

    Yang, Chae Eun; Roh, Tai Suk; Yun, In Sik; Lew, Dae Hyun

    2014-01-01

    Background Currently, breast conservation therapy is commonly performed for the treatment of early breast cancer. Depending on the volume excised, patients may require volume replacement, even in cases of partial mastectomy. The use of the latissimus dorsi muscle is the standard method, but this procedure leaves an unfavorable scar on the donor site. We used an endoscope for latissimus dorsi harvesting to minimize the incision, thus reducing postoperative scars. Methods Ten patients who underwent partial mastectomy and immediate partial breast reconstruction with endoscopic latissimus dorsi muscle flap harvest were reviewed retrospectively. The total operation time, hospital stay, and complications were reviewed. Postoperative scarring, overall shape of the reconstructed breast, and donor site deformity were assessed using a 10-point scale. Results In the mean follow-up of 11 weeks, no tumor recurrence was reported. The mean operation time was 294.5 (±38.2) minutes. The postoperative hospital stay was 11.4 days. Donor site seroma was reported in four cases and managed by office aspiration and compressive dressing. Postoperative scarring, donor site deformity, and the overall shape of the neobreast were acceptable, scoring above 7. Conclusions Replacement of 20% to 40% of breast volume in the upper and the lower outer quadrants with a latissimus dorsi muscle flap by using endoscopic harvesting is a good alternative reconstruction technique after partial mastectomy. Short incision benefits from a very acceptable postoperative scar, less pain, and early upper extremity movement. PMID:25276643

  10. Endoscopic root canal treatment.

    PubMed

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  11. [Can Glasgow-Blatchford Score and Pre-endoscopic Rockall Score Predict the Occurrence of Hypotension in Initially Normotensive Patients with Non-variceal Upper Gastrointestinal Bleeding?].

    PubMed

    Kim, June Sung; Ko, Byuk Sung; Son, Chang Hwan; Ahn, Shin; Seo, Dong Woo; Lee, Yoon Seon; Lee, Jae Ho; Oh, Bum Jin; Lim, Kyoung Soo; Kim, Won Young

    2016-01-25

    The aim of this study was to identify the ability of Glasgow-Blatchford score (GBS) and pre-endoscopic Rockall score (pre-E RS) to predict the occurrence of hypotension in patients with non-variceal upper gastrointestinal bleeding who are initially normotensive at emergency department. Retrospective observational study was conducted at Asan Medical Center emergency department (ED) in patients who presented with non-variceal upper gastrointestinal bleeding from January 1, 2011 to December 31, 2013. Study population was divided according to the development of hypotension, and demographics, comorbidities, and laboratory findings were compared. GBS and pre-E RS were estimated to predict the occurrence of hypotension. A total of 747 patients with non-variceal upper gastrointestinal bleeding were included during the study period, and 120 (16.1%) patients developed hypotension within 24 hours after ED admission. The median values GBS and pre-E RS were statistically different according to the occurrence of hypotension (8.0 vs. 10.0, 2.0 vs. 3.0, respectively; p<0.001). In the receiver operating characteristic curve analysis of hypotension development, the area under the curve of GBS and pre-E RS were 66% and 64%, respectively. The sensitivity and the specificity of GBS using optimal cut-off value were 81% and 46%, respectively, while those based on the pre-E RS were 74% and 46%, respectively. GBS and pre-E RS were both not sufficient for predicting the occurrence of hypotension in non-variceal upper gastrointestinal bleeding. Development of other scoring systems are needed.

  12. Low-cost endoscopic third ventriculostomy simulator with mimetic endoscope.

    PubMed

    Garling, Richard Justin; Jin, Xin; Yang, Jianzhong; Khasawneh, Ahmad H; Harris, Carolyn Anne

    2018-05-11

    OBJECTIVE Hydrocephalus affects approximately 1 in 500 people in the US, yet ventricular shunting, the gold standard of treatment, has a nearly 85% failure rate. Endoscopic third ventriculostomy (ETV) is an alternative surgical approach for a specific subset of hydrocephalic patients, but can be limited by the inability of neurosurgical residents to practice prior to patient contact. The goal of this study was to create an affordable ETV model and endoscope for resident training. METHODS Open-source software was used to isolate the skull and brain from the CT and MR images of a 2-year-old boy with hydrocephalus. A 3D printer created the skull and a 3D mold of the brain. A mixture of silicone and silicone tactile mutator was used to cast the brain mold prior to subsequent compression and shearing modulus testing. A mimetic endoscope was then created from basic supplies and a 3D printed frame. A small cohort of neurosurgical residents and attending physicians evaluated the ETV simulator with mimetic endoscope. RESULTS The authors successfully created a mimetic endoscope and ETV simulator. After compression and shearing modulus testing, a silicone/Slacker ratio between 10:6 and 10:7 was found to be similar to that of human brain parenchyma. Eighty-seven percent of participants strongly agreed that the simulator was useful for resident training, and 93% strongly agreed that the simulator helped them understand how to orient themselves with the endoscope. CONCLUSIONS The authors created an affordable (US$123, excluding 3D printer), easy-to-use ETV simulator with endoscope. Previous models have required expensive software and costly operative endoscopes that may not be available to most residents. Instead, this attempt takes advantage of open-source software for the manipulation and fabrication of a patient-specific mold. This model can assist with resident development, allowing them to safely practice use of the endoscope in ETV.

  13. Antiplatelet agents and/or anticoagulants are not associated with worse outcome following nonvariceal upper gastrointestinal bleeding.

    PubMed

    Teles-Sampaio, Elvira; Maia, Luís; Salgueiro, Paulo; Marcos-Pinto, Ricardo; Dinis-Ribeiro, Mário; Pedroto, Isabel

    2016-11-01

    Nonvariceal upper gastrointestinal bleeding emerges as a major complication of using antiplatelet agents and/or anticoagulants and represents a clinical challenge in patients undergoing these therapies. To characterize patients with nonvariceal upper gastrointestinal bleeding related to antithrombotics and their management, and to determine clinical predictors of adverse outcomes. Retrospective cohort of adults who underwent upper gastrointestinal endoscopy after nonvariceal upper gastrointestinal bleeding from 2010 to 2012. The outcomes were compared between patients exposed and not exposed to antithrombotics. Five hundred and forty-eight patients with nonvariceal upper gastrointestinal bleeding (67% men; mean age 66.5 ± 16.4 years) were included, of which 43% received antithrombotics. Most patients had comorbidities. Peptic ulcer was the main diagnosis and endoscopic therapy was performed in 46% of cases. The 30-day mortality rate was 7.7% (n = 42), and 36% were bleeding-related. The recurrence rate was 9% and 14% of patients with initial endoscopic treatment needed endoscopic retreatment. There were no significant differences between the exposed and non-exposed groups in most outcomes. Co-morbidities, hemodynamic instability, high Rockall score, low hemoglobin (7.76 ± 2.72 g/dL) and higher international normalized ratio (1.63 ± 1.13) were associated significantly with mortality in a univariate analysis. Adverse outcomes were not associated with antithrombotic use. The management of nonvariceal upper gastrointestinal bleeding constitutes a challenge to clinical performance optimization and clinical cooperation.

  14. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    PubMed

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P < 0.001). Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  15. Endoscopic ultrasound

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  16. Endoscopic removal of over-the-scope clips: Clinical experience with a bipolar cutting device

    PubMed Central

    Meier, Benjamin; Caca, Karel; Schmidt, Arthur

    2016-01-01

    Background Over-the-scope clips (OTSCs) are increasingly used for the closure of perforations/fistulae, hemostasis and endoscopic full-thickness resection (FTRD system). When OTSC-associated complications occur or re-therapy at the OTSC site is needed, OTSC removal may be indicated. An experimental study in an animal model and a case series have shown good results for OTSC removal with a bipolar cutting device. We present a larger clinical study using this device. Methods Data of all consecutive patients with indication for OTSC removal were collected and analyzed retrospectively. OTSCs were cut at two opposing sites using a bipolar grasping device to apply short direct current impulses. OTSC fragments were extracted with a standard forceps and a cap at the tip of the endoscope to avoid tissue damage. Results Between December 2012 and February 2016 a total of 42 OTSC removals in the upper (n = 25) and lower (n = 17) gastrointestinal tract have been performed at our department. Overall technical success, defined as cutting the OTSC at two opposing sites and extraction of both fragments, was achieved in 92.9% (39/42) of all cases. Successful fragmentation of the OTSC was achieved in 97.6% (41/42). Minor bleedings were rare and could be managed endoscopically in all cases. There were no perforations and no major or delayed bleedings. Conclusion Endoscopic OTSC removal with a bipolar cutting device is feasible, effective and safe. This technique can be applied in the upper and lower gastrointestinal tract. PMID:28588877

  17. Direct peroral cholangioscopy using an ultrathin endoscope: making technique easier.

    PubMed

    Sola-Vera, Javier; Uceda, Francisco; Cuesta, Rubén; Vázquez, Narcís

    2014-01-01

    Cholangioscopy is a useful tool for the study and treatment of biliary pathology. Ultrathin upper endoscopes allow direct peroral cholangioscopy (DPC) but have some drawbacks. The aim of the study was to evaluate the success rate of DPC with an ultrathin endoscope using a balloon catheter to reach the biliary confluence. Prospective observational study. An ultrathin endoscope (Olympus XP180N, outer diameter 5.5 mm, working channel 2 mm) was used. To access the biliary tree, free-hand technique was used. To reach the biliary confluence an intraductal balloon catheter (Olympus B5-2Q diameter 1.9 mm) and a 0.025 inch guide wire was used. In all cases sphincterotomy and/or sphincteroplasty was performed. The success rate was defined as the percentage of cases in which the biliary confluence could be reached with the ultrathin endoscope. Fifteen patients (8 men/7 women) were included. Mean age was 77.7 + or - 10.8 years (range 45-91). The indications for cholangioscopy were suspected bile duct stones (n = 9), electrohydraulic lithotripsy for the treatment of difficult choledocholithiasis (n = 5) and evaluation of biliary stricture (n = 1). Access to the bile duct was achieved in 14/15 cases (93.3%). Biliary confluence was reached in 13/15 cases (86.7%). One complication was observed in one patient (oxigen desaturation). DPC with an ultrathin endoscope can be done with the free-hand technique. Intraductal balloon-guided DPC allows full examination of the common bile duct in most cases.

  18. Transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding: Indications, techniques and outcomes.

    PubMed

    Loffroy, R; Favelier, S; Pottecher, P; Estivalet, L; Genson, P Y; Gehin, S; Cercueil, J P; Krausé, D

    2015-01-01

    Over the past three decades, transcatheter arterial embolization has become the first-line therapy for the management of acute nonvariceal upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the treatment of bleeding for a variety of indications. Transcatheter arterial embolization is a fast, safe, and effective minimally invasive alternative to surgery, when endoscopic treatment fails to control acute bleeding from the upper gastrointestinal tract. This article describes the role of arterial embolization in the management of acute nonvariceal upper gastrointestinal bleeding and summarizes the literature evidence on the outcomes of endovascular therapy in such a setting. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  19. Endoscope field of view measurement.

    PubMed

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-03-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.

  20. Endoscope field of view measurement

    PubMed Central

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-01-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840

  1. Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection

    PubMed Central

    Jang, Jae-Young

    2017-01-01

    Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819

  2. Echocardiographic demonstration of intracardiac glue after endoscopic obturation of gastroesophageal varices.

    PubMed

    Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M

    1995-01-01

    Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.

  3. [Prediction of the efficiency of endoscopic lung volume reduction by valves in severe emphysema].

    PubMed

    Bocquillon, V; Briault, A; Reymond, E; Arbib, F; Jankowski, A; Ferretti, G; Pison, C

    2016-11-01

    In severe emphysema, endoscopic lung volume reduction with valves is an alternative to surgery with less morbidity and mortality. In 2015, selection of patients who will respond to this technique is based on emphysema heterogeneity, a complete fissure visible on the CT-scan and absence of collateral ventilation between lobes. Our case report highlights that individualized prediction is possible. A 58-year-old woman had severe, disabling pulmonary emphysema. A high resolution thoracic computed tomography scan showed that the emphysema was heterogeneous, predominantly in the upper lobes, integrity of the left greater fissure and no collateral ventilation with the left lower lobe. A valve was inserted in the left upper lobe bronchus. At one year, clinical and functional benefits were significant with complete atelectasis of the treated lobe. The success of endoscopic lung volume reduction with a valve can be predicted, an example of personalized medicine. Copyright © 2016 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  4. Place of upper endoscopy before and after bariatric surgery: A multicenter experience with 3219 patients

    PubMed Central

    Abd Ellatif, Mohamed E; Alfalah, Haitham; Asker, Walid A; El Nakeeb, Ayman E; Magdy, Alaa; Thabet, Waleed; Ghaith, Mohamed A; Abdallah, Emad; Shahin, Rania; Shoma, Asharf; Dawoud, Ibraheim E; Abbas, Ashraf; Salama, Asaad F; Ali Gamal, Maged

    2016-01-01

    AIM: To study the preoperative and postoperative role of upper esophagogastroduodenoscopy (EGD) in morbidly obese patients. METHODS: This is a multicenter retrospective study by reviewing the database of patients who underwent bariatric surgery (laparoscopic sleeve gastrectomy, laparoscopic Roux en Y gastric bypass, or laparoscopic minigastric bypass) in the period between 2001 June and 2015 August (Jahra Hospital-Kuwait, Hafr Elbatin Hospital and King Saud Medical City-KSA, and Mansoura University Hospital - Egypt). Patients with age 18-65 years, body mass index (BMI) > 40, or > 35 with comorbidities after failure of many dietetic regimen and acceptable levels of surgical risk were included in the study after having an informed signed consent. We retrospectively reviewed the medical charts of all morbidly obese patients. The patients’ preoperative data included clinical history including upper digestive symptoms and preoperative full workup including EGD. Only patients whose charts revealed weather they were symptomatic or not were studied. We categorized patients accordingly into two groups; with (group A) or without (group B) upper digestive symptoms. The endoscopic findings were categorized into 4 groups based on predetermined criteria. The medical record of patients who developed stricture, leak or bleeding after bariatric surgery was reviewed. Logestic regression analysis was used to identify preoperative predictors that might be associated with abnormal endoscopic findings. RESULTS: Three thousand, two hundred and nineteen patients in the study period underwent bariatric surgery (75% LSG, 10% LRYDB, and 15% MGB). Mean BMI was 43 ± 13, mean age 37 ± 9 years, 79% were female. Twenty eight percent had presented with upper digestive symptoms (group A). EGD was considered normal in 2414 (75%) patients (9% group A vs 66% group B, P = 0.001). The abnormal endoscopic findings were found high in those patients with upper digestive symptoms. Abnormal findings (one

  5. Capturing and stitching images with a large viewing angle and low distortion properties for upper gastrointestinal endoscopy

    NASA Astrophysics Data System (ADS)

    Liu, Ya-Cheng; Chung, Chien-Kai; Lai, Jyun-Yi; Chang, Han-Chao; Hsu, Feng-Yi

    2013-06-01

    Upper gastrointestinal endoscopies are primarily performed to observe the pathologies of the esophagus, stomach, and duodenum. However, when an endoscope is pushed into the esophagus or stomach by the physician, the organs behave similar to a balloon being gradually inflated. Consequently, their shapes and depth-of-field of images change continually, preventing thorough examination of the inflammation or anabrosis position, which delays the curing period. In this study, a 2.9-mm image-capturing module and a convoluted mechanism was incorporated into the tube like a standard 10- mm upper gastrointestinal endoscope. The scale-invariant feature transform (SIFT) algorithm was adopted to implement disease feature extraction on a koala doll. Following feature extraction, the smoothly varying affine stitching (SVAS) method was employed to resolve stitching distortion problems. Subsequently, the real-time splice software developed in this study was embedded in an upper gastrointestinal endoscope to obtain a panoramic view of stomach inflammation in the captured images. The results showed that the 2.9-mm image-capturing module can provide approximately 50 verified images in one spin cycle, a viewing angle of 120° can be attained, and less than 10% distortion can be achieved in each image. Therefore, these methods can solve the problems encountered when using a standard 10-mm upper gastrointestinal endoscope with a single camera, such as image distortion, and partial inflammation displays. The results also showed that the SIFT algorithm provides the highest correct matching rate, and the SVAS method can be employed to resolve the parallax problems caused by stitching together images of different flat surfaces.

  6. Flexible endoscopes: structure and function: the endoscopic retrograde cholangiopancreatography elevator system.

    PubMed

    Holland, Pat; Shoop, Nancy M

    2002-01-01

    Flexible endoscopes are complex medical instruments that are easily damaged. In order to maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the fourth in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first three articles discussed the air-water system, the suction channel system, and the mechanical system. This article will focus specifically on the endoscopic retrograde cholangiopancreatography elevator system.

  7. Cost-Minimization Analysis of Open and Endoscopic Carpal Tunnel Release.

    PubMed

    Zhang, Steven; Vora, Molly; Harris, Alex H S; Baker, Laurence; Curtin, Catherine; Kamal, Robin N

    2016-12-07

    Carpal tunnel release is the most common upper-limb surgical procedure performed annually in the U.S. There are 2 surgical methods of carpal tunnel release: open or endoscopic. Currently, there is no clear clinical or economic evidence supporting the use of one procedure over the other. We completed a cost-minimization analysis of open and endoscopic carpal tunnel release, testing the null hypothesis that there is no difference between the procedures in terms of cost. We conducted a retrospective review using a private-payer and Medicare Advantage database composed of 16 million patient records from 2007 to 2014. The cohort consisted of records with an ICD-9 (International Classification of Diseases, Ninth Revision) diagnosis of carpal tunnel syndrome and a CPT (Current Procedural Terminology) code for carpal tunnel release. Payer fees were used to define cost. We also assessed other associated costs of care, including those of electrodiagnostic studies and occupational therapy. Bivariate comparisons were performed using the chi-square test and the Student t test. Data showed that 86% of the patients underwent open carpal tunnel release. Reimbursement fees for endoscopic release were significantly higher than for open release. Facility fees were responsible for most of the difference between the procedures in reimbursement: facility fees averaged $1,884 for endoscopic release compared with $1,080 for open release (p < 0.0001). Endoscopic release also demonstrated significantly higher physician fees than open release (an average of $555 compared with $428; p < 0.0001). Occupational therapy fees associated with endoscopic release were less than those associated with open release (an average of $237 per session compared with $272; p = 0.07). The total average annual reimbursement per patient for endoscopic release (facility, surgeon, and occupational therapy fees) was significantly higher than for open release ($2,602 compared with $1,751; p < 0.0001). Our data showed

  8. Efficacy of ankaferd blood stopper application on non-variceal upper gastrointestinal bleeding

    PubMed Central

    Gungor, Gokhan; Goktepe, M Hakan; Biyik, Murat; Polat, Ilker; Tuna, Tuncer; Ataseven, Huseyin; Demir, Ali

    2012-01-01

    AIM: To prospectively assess the hemostatic efficacy of the endoscopic topical use of ankaferd blood stopper (ABS) in active non-variceal upper gastrointestinal system (GIS) bleeding. METHODS: Endoscopy was performed on 220 patients under suspiciency of GIS bleeding. Patients with active non-variceal upper gastrointestinal bleeding (NVUGIB) with a spurting or oozing type were included. Firstly, 8-10 cc of isotonic saline was sprayed to bleeding lesions. Then, 8 cc of ABS was applied on lesions in which bleeding continued after isotonic saline application. The other endoscopic therapeutic methods were applied on the lesions in which the bleeding did not stop after ABS. RESULTS: Twenty-seven patients had an active NVUGIB with a spurting or oozing type and 193 patients were excluded from the study since they did not have non-variceal active bleeding. 8 cc of ABS was sprayed on to the lesions of 26 patients whose bleeding continued after isotonic saline and in 19 of them, bleeding stopped after ABS. Other endoscopic treatment methods were applied to the remaining patients and the bleeding was stopped with these interventions in 6 of 7 patients. CONCLUSION: ABS is an effective method on NVUGIB, particularly on young patients with no coagulopathy. ABS may be considered as part of a combination treatment with other endoscopic methods. PMID:23293725

  9. Endoscopic Carbon Dioxide Laser Photocoagulation Of Bleeding Canine Gastric Ulcers

    NASA Astrophysics Data System (ADS)

    Gal, Dov; Ron, Nimrod; Orgad, Uri; Katzir, Abraham

    1987-04-01

    This is the first report which describes carbon dioxide laser photocoagulation of upper gastrointestinal bleeding via a flexible endoscope, using an infrared transmitting siver nalide fiber. Various laser parameters were checked to determine the optimal conditions for hemostasis. Both the acute effects of laser irradiation on tissue and the chronic effects on healing process were examined. Preliminary results indicate that carbon dioxide laser beam can successfully photocoagulate moderately bleeding ulcers.

  10. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    PubMed

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  11. Ergonomics and human factors in endoscopic surgery: a comparison of manual vs telerobotic simulation systems.

    PubMed

    Lee, E C; Rafiq, A; Merrell, R; Ackerman, R; Dennerlein, J T

    2005-08-01

    Minimally invasive surgical techniques expose surgeons to a variety of occupational hazards that may promote musculoskeletal disorders. Telerobotic systems for minimally invasive surgery may help to reduce these stressors. The objective of this study was to compare manual and telerobotic endoscopic surgery in terms of postural and mental stress. Thirteen participants with no experience as primary surgeons in endoscopic surgery performed a set of simulated surgical tasks using two different techniques--a telerobotic master--slave system and a manual endoscopic surgery system. The tasks consisted of passing a soft spherical object through a series of parallel rings, suturing along a line 5-cm long, running a 32-in ribbon, and cannulation. The Job Strain Index (JSI) and Rapid Upper Limb Assessment (RULA) were used to quantify upper extremity exposure to postural and force risk factors. Task duration was quantified in seconds. A questionnaire provided measures of the participants' intuitiveness and mental stress. The JSI and RULA scores for all four tasks were significantly lower for the telerobotic technique than for the manual one. Task duration was significantly longer for telerobotic than for manual tasks. Participants reported that the telerobotic technique was as intuitive as, and no more stressful than, the manual technique. Given identical tasks, the time to completion is longer using the telerobotic technique than its manual counterpart. For the given simulated tasks in the laboratory setting, the better scores for the upper extremity postural analysis indicate that telerobotic surgery provides a more comfortable environment for the surgeon without any additional mental stress.

  12. The Clinical Accuracy of Endoscopic Ultrasonography and White Light Imaging in Gastric Endoscopic Submucosal Dissection

    PubMed Central

    Park, Soon Hong; Sung, Sang Hun; Lee, Seung Jun; Jung, Min Kyu; Kim, Sung Kook

    2012-01-01

    Purpose Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection. PMID:22792522

  13. Endoscopic injection therapy.

    PubMed

    Kim, Sang Woon; Lee, Yong Seung; Han, Sang Won

    2017-06-01

    Since the U.S. Food and Drug Administration approved dextranomer/hyaluronic acid copolymer (Deflux) for the treatment of vesicoureteral reflux, endoscopic injection therapy using Deflux has become a popular alternative to open surgery and continuous antibiotic prophylaxis. Endoscopic correction with Deflux is minimally invasive, well tolerated, and provides cure rates approaching those of open surgery (i.e., approximately 80% in several studies). However, in recent years a less stringent approach to evaluating urinary tract infections (UTIs) and concerns about long-term efficacy and complications associated with endoscopic injection have limited the use of this therapy. In addition, there is little evidence supporting the efficacy of endoscopic injection therapy in preventing UTIs and vesicoureteral reflux-related renal scarring. In this report, we reviewed the current literature regarding endoscopic injection therapy and provided an updated overview of this topic.

  14. Recent advances in endovascular techniques for management of acute nonvariceal upper gastrointestinal bleeding

    PubMed Central

    Loffroy, Romaric F; Abualsaud, Basem A; Lin, Ming D; Rao, Pramod P

    2011-01-01

    Over the past two decades, transcatheter arterial embolization has become the first-line therapy for the management of upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the management of hemorrhage for a variety of indications, such as peptic ulcer bleeding, malignant disease, hemorrhagic Dieulafoy lesions and iatrogenic or trauma bleeding. Transcatheter interventions include the following: selective embolization of the feeding artery, sandwich coil occlusion of the gastroduodenal artery, blind or empiric embolization of the supposed bleeding vessel based on endoscopic findings and coil pseudoaneurysm or aneurysm embolization by three-dimensional sac packing with preservation of the parent artery. Transcatheter embolization is a fast, safe and effective, minimally invasive alternative to surgery when endoscopic treatment fails to control bleeding from the upper gastrointestinal tract. This article reviews the various transcatheter endovascular techniques and devices that are used in a variety of clinical scenarios for the management of hemorrhagic gastrointestinal emergencies. PMID:21860697

  15. Endoscopic laser recanalisation of presaccal canalicular obstruction

    PubMed Central

    Kuchar, A.; Novak, P.; Pieh, S.; Fink, M.; Steinkogler, F. J.

    1999-01-01

    AIM—To document the results of erbium (Er)-YAG laser treatment in presaccal canalicular obstruction in combination with the use of a flexible endoscope.
METHODS—For the first time an Er-YAG laser (Schwind, Sklerostom) was attached to a flexible endoscope (Schwind, Endognost) and used to recanalise a stenosis of the upper, lower, or common canaliculus. In 17 patients (mean age 41.5 (SD 11.9) years), 19 treatments (two bilateral) were performed. In all cases the scar was observed using the endoscope and was excised by laser ablation. A silicone intubation was performed in all cases. In addition to the endoscopy an irrigation was performed to prove the intactness of the lacrimal pathway system after laser treatment.
RESULTS—Membranous obstructions with a maximum length of 2.0 mm (14 procedures) in the canaliculus were opened easily using the laser, and the silicone intubation was subsequently performed without difficulty. Scars thicker than 2.0 mm could not be opened safely without canaliculus penetration (five procedures). Irrigation was positive in all cases up to the end of a 6 month period, providing the tubes remained in place. The maximum follow up is now 17 months (minimum 8 months) and in 16 cases (84.2%) the canaliculi are still intact.
CONCLUSION—Endoscopic laser treatment combined with silicone intubation enables us to recanalise presaccal stenoses of canaliculi under local anaesthesia up to a scar thickness of 2.0 mm. Best results can be achieved in cases where much tissue can be saved. Under such conditions this procedure can substitute for more invasive surgical techniques, especially a conjunctivo-dacryocystorhinostomy (CDCR).

 Keywords: laser recanalisation; presaccal canalicular obstruction; endoscopy PMID:10434867

  16. Endoscopic ultrasonography predicts early esophageal variceal bleeding in liver cirrhosis: A case report.

    PubMed

    Men, Changjun; Zhang, Guoliang

    2017-04-01

    Bleeding esophageal and gastric varices constitute a serious complication in liver cirrhosis. Previous studies have shown that endoscopic ultrasonography (EUS) can be used to predict early esophageal variceal bleeding in liver cirrhosis. We report a case of a 46-year-old man with hepatitis B liver cirrhosis (CTP score, 5; Child-Pugh class, A) who was admitted to our hospital due to a decreased appetite lasting 1 week. He was initially diagnosed with decompensated hepatitis B cirrhosis; an abdominal computed tomography (CT) scan indicated a diagnosis of liver cirrhosis and portal hypertension (PHT). Common endoscopic examination showed no evidence of gastroesophageal varices; EUS revealed distinct varices of the esophageal and gastric veins. Six months after discharge, the patient was rehospitalized because of upper gastrointestinal bleeding. Endoscopic ligation was implemented as well as esophageal varices loop ligature (EVL). Six months later, EUS showed obvious collateral and perforator veins. We should strongly recommend that patients with liver cirrhosis undergo EUS in addition to a routine endoscopic examination. EUS can play an important role in evaluating the risk for bleeding in PHT and can be used to assess the efficacy of EVL.

  17. Endoscopic removal of a tablespoon lodged within the duodenum

    PubMed Central

    Watanabe, Takashi; Aoyagi, Kunihiko; Tomioka, Yoshitaka; Ishibashi, Hideki; Sakisaka, Shotaro

    2015-01-01

    Here we report the case of a 34-year-old man who underwent endoscopic removal of a tablespoon from the stomach that was lodged within the duodenum. Removal required the use of a two-channel upper endoscope and polypectomy snares. Using the double-snare technique, the spoon was grasped at the proximal and distal parts of the handle. The double-snare was first pulled unsuccessfully and then pulled with simultaneous manual abdominal compression of the bulbus from the body surface. Compression was gently applied towards the stomach. As a result, the head of the spoon prolapsed from the bulbus, and was easily retracted from the stomach without any complications. In cases of foreign body lodging within the duodenum, the manual abdominal compression technique may help clinicians pull out the object and avoid surgery. The usefulness of manual compression is dependent on the foreign body’s sharpness and the location. PMID:25945026

  18. Multiband mucosectomy for advanced dysplastic lesions in the upper digestive tract

    PubMed Central

    Espinel, Jesús; Pinedo, Eugenia; Ojeda, Vanesa; del Rio, Maria Guerra

    2015-01-01

    Endoscopic resection (ER) is at present an accepted treatment for superficial gastrointestinal neoplasia. ER provides similar efficacy to surgery; however, it is minimally invasive and less expensive. Endoscopic mucosal resection (EMR) is superior to biopsy for diagnosing advanced dysplasia and can change the diagnostic grade and the management. Several EMR techniques have been described that are alternatively used dependent upon the endoscopist personal experience, the anatomic conditions and the endoscopic appearance of the lesion to be resected. The literature suggests that EMR offers comparable outcomes to surgery for selected indications. EMR techniques using a cap fitted endoscope and EMR using a ligation device [multiband mucosectomy (MBM)] are the most frequently use. MBM technique does not require submucosal injection as with the endoscopic resection-cap technique, multiple resections can be performed with the same snare, pre-looping the endoscopic resection-snare in the ridge of the cap is not necessary, MBM does not require withdrawal of the endoscope between resections and up to six consecutive resections can be performed. This reduces the time and cost required for the procedure, while also reducing patient discomfort. Despite the increasing popularity of MBM, data on the safety and efficacy of this technique in upper gastrointestinal lesions with advanced dysplasia, defined as those lesions that have high-grade dysplasia or early cancer, is limited. PMID:25901216

  19. Reliability in endoscopic diagnosis of portal hypertensive gastropathy

    PubMed Central

    de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista

    2013-01-01

    AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern

  20. Sparse aperture endoscope

    DOEpatents

    Fitch, J.P.

    1999-07-06

    An endoscope is disclosed which reduces the volume needed by the imaging part, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases it's utility. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing. 7 figs.

  1. Sparse aperture endoscope

    DOEpatents

    Fitch, Joseph P.

    1999-07-06

    An endoscope which reduces the volume needed by the imaging part thereof, maintains resolution of a wide diameter optical system, while increasing tool access, and allows stereographic or interferometric processing for depth and perspective information/visualization. Because the endoscope decreases the volume consumed by imaging optics such allows a larger fraction of the volume to be used for non-imaging tools, which allows smaller incisions in surgical and diagnostic medical applications thus produces less trauma to the patient or allows access to smaller volumes than is possible with larger instruments. The endoscope utilizes fiber optic light pipes in an outer layer for illumination, a multi-pupil imaging system in an inner annulus, and an access channel for other tools in the center. The endoscope is amenable to implementation as a flexible scope, and thus increases the utility thereof. Because the endoscope uses a multi-aperture pupil, it can also be utilized as an optical array, allowing stereographic and interferometric processing.

  2. Successful endoscopic treatment of gastric phytobezoar: A case report.

    PubMed

    Ugenti, Ippazio; Travaglio, Elisabetta; Lagouvardou, Elpiniki; Caputi Iambrenghi, Onofrio; Martines, Gennaro

    2017-01-01

    Gastric bezoars are a rare condition associated with situations of gastric dysmotility and prior gastric surgery, though sometimes they can present without any risk factor. We describe the first successful treatment in medical literature of a large gastric bezoar in the outpatient setting through endoscopic fragmentation. A 76-year-old man was referred to our outpatient endoscopy clinic because of dyspepsia and epigastric pain. Upper GI endoscopy with a standard endoscope revealed a 10-cm-diameter gastric phytobezoar with necrotic pressure ulcer of the angulus. We fragmentized the bezoar into smaller pieces, with complete dissolution and without any complication. The patient was then promptly discharged home with a medical therapy. Follow-up endoscopy at 6 months showed the total disappearance of any residual fibers. Different types of bezoars are described in literature, of which phyto- and trychobezoars are the most frequent. They can be absolutely asymptomatic or can arise with epigastric pain, pressure ulcer bleeding, gastrointestinal perforation or small bowel obstruction. The treatment is debated though endoscopic removal or fragmentation with the help of Coca-Cola lavages has showed the best success rate. The main experiences in literature concern hospitalized patients or describe treatment techniques which require overnight stays. An effective and rapid treatment in the outpatient setting is described in our experience, without short- or long-term complications. The endoscopic fragmentation of large gastric bezoars in the outpatient setting is safe with a good clinical course. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Recurrent Upside-Down Stomach after Endoscopic Repositioning and Gastropexy Treated by Laparoscopic Surgery

    PubMed Central

    Toyota, Kazuhiro; Sugawara, Yuji; Hatano, Yu

    2014-01-01

    Patients with an upside-down stomach usually receive surgical treatment. In high-risk patients, endoscopic repositioning and gastropexy can be performed. However, the risk of recurrence after endoscopic treatment is not known. We treated a case of recurrent upside-down stomach after endoscopic therapy that indicated the limits of endoscopic treatment and risk of recurrence. An 88-year-old woman was treated three times for vomiting in the past. She presented to our hospital with periodic vomiting and an inability to eat, and a diagnosis of upside-down stomach was made. Endoscopic repositioning and gastropexy were performed. The anterior stomach wall was fixed to the abdominal wall in three places as widely as possible. Following treatment, she became symptom-free. Three months later, she was hospitalized again because of a recurrent upside-down stomach. Laparoscopic repair of hernias and gastropexy was performed. Using a laparoscope, two causes of recurrence were found. One cause was that the range of adherence between the stomach and the abdominal wall was narrow (from the antrum only to the lower corpus of stomach), so the upper corpus of stomach was rotated and herniated into the esophageal hiatus. The other cause was adhesion between the omentum and the esophageal hiatus which caused the stomach to rotate and repeatedly become herniated. Although endoscopic treatment for upside-down stomach can be a useful alternative method in high-risk patients, its ability to prevent recurrence is limited. Moreover, a repeated case caused by adhesions has risks of recurrence. PMID:24574947

  4. Recurrent upside-down stomach after endoscopic repositioning and gastropexy treated by laparoscopic surgery.

    PubMed

    Toyota, Kazuhiro; Sugawara, Yuji; Hatano, Yu

    2014-01-01

    Patients with an upside-down stomach usually receive surgical treatment. In high-risk patients, endoscopic repositioning and gastropexy can be performed. However, the risk of recurrence after endoscopic treatment is not known. We treated a case of recurrent upside-down stomach after endoscopic therapy that indicated the limits of endoscopic treatment and risk of recurrence. An 88-year-old woman was treated three times for vomiting in the past. She presented to our hospital with periodic vomiting and an inability to eat, and a diagnosis of upside-down stomach was made. Endoscopic repositioning and gastropexy were performed. The anterior stomach wall was fixed to the abdominal wall in three places as widely as possible. Following treatment, she became symptom-free. Three months later, she was hospitalized again because of a recurrent upside-down stomach. Laparoscopic repair of hernias and gastropexy was performed. Using a laparoscope, two causes of recurrence were found. One cause was that the range of adherence between the stomach and the abdominal wall was narrow (from the antrum only to the lower corpus of stomach), so the upper corpus of stomach was rotated and herniated into the esophageal hiatus. The other cause was adhesion between the omentum and the esophageal hiatus which caused the stomach to rotate and repeatedly become herniated. Although endoscopic treatment for upside-down stomach can be a useful alternative method in high-risk patients, its ability to prevent recurrence is limited. Moreover, a repeated case caused by adhesions has risks of recurrence.

  5. A Rare Case of Pancreas Divisum Accompanied by Acute Pancreatitis Following Endoscopic Hemostasis for Duodenal Ulcer Bleeding.

    PubMed

    Choi, Yong Hyeok; Yoon, Soon Man; Kim, Eun Bee; Oh, Youngmin; Kim, Keunmo; Lee, Jisun; Park, Seon Mee; Youn, Sei Jin

    2017-04-25

    Peptic ulcer bleeding is treated using endoscopic hemostasis using clips or bands. Pancreas divisum (PD), a congenital anomaly of the pancreas, usually has no clinical symptoms; however, pancreatitis may occur if there are disturbances in the drainage of pancreatic secretions. We report an unusual case of PD accompanied by acute pancreatitis, following endoscopic band ligation for duodenal ulcer bleeding. A 48-year-old woman was admitted to our hospital due to melena. An upper endoscopy revealed a small ulcer with oozing adjacent minor papilla. An endoscopic band ligation was performed on this lesion. Acute pancreatitis developed suddenly 6 hours after the band ligation and improved dramatically after removal of the band. Magnetic resonance cholangiopancreatography was performed, revealing complete PD. Endoscopic band ligation is known as the effective method for peptic ulcer bleeding; however, it should be used carefully in duodenal ulcer bleeding near the minor duodenal papilla due to the possibility of PD.

  6. A Fibreoptic endoscopic study of upper gastrointestinal bleeding at Bugando Medical Centre in northwestern Tanzania: A retrospective review of 240 cases

    PubMed Central

    2012-01-01

    Background Upper gastrointestinal (GI) bleeding is recognized as a common and potentially life-threatening abdominal emergency that needs a prompt assessment and aggressive emergency treatment. A retrospective study was undertaken at Bugando Medical Centre in northwestern Tanzania between March 2010 and September 2011 to describe our own experiences with fibreoptic upper GI endoscopy in the management of patients with upper gastrointestinal bleeding in our setting and compare our results with those from other centers in the world. Findings A total of 240 patients representing 18.7% of all patients (i.e. 1292) who had fibreoptic upper GI endoscopy during the study period were studied. Males outnumbered female by a ratio of 2.1:1. Their median age was 37 years and most of patients (60.0%) were aged 40 years and below. The vast majority of the patients (80.4%) presented with haematemesis alone followed by malaena alone in 9.2% of cases. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking prior to the onset of bleeding was recorded in 7.9%, 51.7% and 38.3% of cases respectively. Previous history of peptic ulcer disease was reported in 22(9.2%) patients. Nine (3.8%) patients were HIV positive. The source of bleeding was accurately identified in 97.7% of patients. Diagnostic accuracy was greater within the first 24 h of the bleeding onset, and in the presence of haematemesis. Oesophageal varices were the most frequent cause of upper GI bleeding (51.3%) followed by peptic ulcers in 25.0% of cases. The majority of patients (60.8%) were treated conservatively. Endoscopic and surgical treatments were performed in 30.8% and 5.8% of cases respectively. 140 (58.3%) patients received blood transfusion. The median length of hospitalization was 8 days and it was significantly longer in patients who underwent surgical treatment and those with higher Rockall scores (P < 0.001). Rebleeding was reported in 3.3% of the patients. The overall mortality rate of

  7. A fibreoptic endoscopic study of upper gastrointestinal bleeding at Bugando Medical Centre in northwestern Tanzania: a retrospective review of 240 cases.

    PubMed

    Jaka, Hyasinta; Koy, Mheta; Liwa, Anthony; Kabangila, Rodrick; Mirambo, Mariam; Scheppach, Wolfgang; Mkongo, Eliasa; McHembe, Mabula D; Chalya, Phillipo L

    2012-07-03

    Upper gastrointestinal (GI) bleeding is recognized as a common and potentially life-threatening abdominal emergency that needs a prompt assessment and aggressive emergency treatment. A retrospective study was undertaken at Bugando Medical Centre in northwestern Tanzania between March 2010 and September 2011 to describe our own experiences with fibreoptic upper GI endoscopy in the management of patients with upper gastrointestinal bleeding in our setting and compare our results with those from other centers in the world. A total of 240 patients representing 18.7% of all patients (i.e. 1292) who had fibreoptic upper GI endoscopy during the study period were studied. Males outnumbered female by a ratio of 2.1:1. Their median age was 37 years and most of patients (60.0%) were aged 40 years and below. The vast majority of the patients (80.4%) presented with haematemesis alone followed by malaena alone in 9.2% of cases. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking prior to the onset of bleeding was recorded in 7.9%, 51.7% and 38.3% of cases respectively. Previous history of peptic ulcer disease was reported in 22(9.2%) patients. Nine (3.8%) patients were HIV positive. The source of bleeding was accurately identified in 97.7% of patients. Diagnostic accuracy was greater within the first 24 h of the bleeding onset, and in the presence of haematemesis. Oesophageal varices were the most frequent cause of upper GI bleeding (51.3%) followed by peptic ulcers in 25.0% of cases. The majority of patients (60.8%) were treated conservatively. Endoscopic and surgical treatments were performed in 30.8% and 5.8% of cases respectively. 140 (58.3%) patients received blood transfusion. The median length of hospitalization was 8 days and it was significantly longer in patients who underwent surgical treatment and those with higher Rockall scores (P < 0.001). Rebleeding was reported in 3.3% of the patients. The overall mortality rate of 11.7% was significantly

  8. Endoscopic en bloc resection of an exophytic gastrointestinal stromal tumor with suction excavation technique

    PubMed Central

    Choi, Hyuk Soon; Chun, Hoon Jai; Kim, Kyoung-Oh; Kim, Eun Sun; Keum, Bora; Jeen, Yoon-Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Here, we report the first successful endoscopic resection of an exophytic gastrointestinal stromal tumor (GIST) using a novel perforation-free suction excavation technique. A 49-year-old woman presented for further management of a gastric subepithelial tumor on the lesser curvature of the lower body, originally detected via routine upper gastrointestinal endoscopy. Abdominal computed tomography and endoscopic ultrasound showed a 4-cm extraluminally protruding mass originating from the muscularis propria layer. The patient firmly refused surgical resection owing to potential cardiac problems, and informed consent was obtained for endoscopic removal. Careful dissection and suction of the tumor was repeated until successful extraction was achieved without serosal injury. We named this procedure the suction excavation technique. The tumor’s dimensions were 3.5 cm × 2.8 cm × 2.5 cm. The tumor was positive for C-KIT and CD34 by immunohistochemical staining. The mitotic count was 6/50 high-power fields. The patient was followed for 5 years without tumor recurrence. This case demonstrated the use of endoscopic resection of an exophytic GIST using the suction excavation technique as a potential therapy without surgical resection. PMID:27340363

  9. The Steris Reliance EPS endoscope processing system: a new automated endoscope reprocessing technology.

    PubMed

    2007-01-01

    In this Evaluation, we examine whether the Steris Reliance EPS--a flexible endoscope reprocessing system that was recently introduced to the U.S. market--offers meaningful advantages over "traditional" automated endoscope reprocessors (AERs). Most AERs on the market function similarly to one another. The Reliance EPS, however, includes some unique features that distinguish it from other AERs. For example, it incorporates a "boot" technology for loading the endoscopes into the unit without requiring a lot of endoscope-specific connectors, and it dispenses the germicide used to disinfect the endoscopes from a single-use container. This Evaluation looks at whether the unique features of this model make it a better choice than traditional AERs for reprocessing flexible endoscopes. Our study focuses on whether the Reliance EPS is any more likely to be used correctly-thereby reducing the likelihood that an endoscope will be reprocessed inadequately-and whether the unit possesses any design flaws that could lead to reprocessing failures. We detail the unit's advantages and disadvantages compared with other AERs, and we describe what current users have to say. Our conclusions will help facilities determine whether to select the Reliance EPS.

  10. Endoscopic Skull Base Surgery

    PubMed Central

    Senior, Brent A

    2008-01-01

    Endoscopic skull base surgery has undergone rapid advancement in the past decade moving from pituitary surgery to suprasellar lesions and now to a myriad of lesions extending from the cribriform plate to C2 and laterally out to the infratemporal fossa and petrous apex. Evolution of several technological advances as well as advances in understanding of endoscopic anatomy and the development of surgical techniques both in resection and reconstruction have fostered this capability. Management of benign disease via endoscopic methods is largely accepted now but more data is needed before the controversy on the role of endoscopic management of malignant disease is decided. Continued advances in surgical technique, navigation systems, endoscopic imaging technology, and robotics assure continued brisk evolution in this expanding field. PMID:19434274

  11. Implementing the SOHN-endorsed AORN guidelines for reprocessing reusable upper airway endoscopes.

    PubMed

    Rudy, Susan F; Adams, Jan; Waddington, Carolyn

    2012-01-01

    This is a companion paper to two previous publications on recommended practices for cleaning and reprocessing flexible endoscopes used in Otolaryngology (Burlingame, Arcilla, & McDermott, 2008; Adams & Baker, 2010). In this paper we capture and expand upon the audience question and answer session in which the Society of Otorhinolaryngology and Head-Neck Nurse (SOHN)--endorsed the Association of periOperative Registered Nurses (AORN) recommended practices were presented to the SOHN membership (Adams & Waddington, September, 2010). We include additional background information to assist readers in understanding some of the science behind the recommendations and share successful implementation strategies from Otorhinolaryngology (ORL) outpatient nurses and published references.

  12. Combined use of clips and nylon snare ("tulip-bundle") as a rescue endoscopic bleeding control in a mallory-weiss syndrome.

    PubMed

    Ivekovic, Hrvoje; Radulovic, Bojana; Jankovic, Suzana; Markos, Pave; Rustemovic, Nadan

    2014-01-01

    Mallory-Weiss syndrome (MWS) accounts for 6-14% of all cases of upper gastrointestinal bleeding. Prognosis of patients with MWS is generally good, with a benign course and rare recurrence of bleeding. However, no strict recommendations exist in regard to the mode of action after a failure of primary endoscopic hemostasis. We report a case of an 83-year-old male with MWS and rebleeding after the initial endoscopic treatment with epinephrine and clips. The final endoscopic control of bleeding was achieved by a combined application of clips and a nylon snare in a "tulip-bundle" fashion. The patient had an uneventful postprocedural clinical course and was discharged from the hospital five days later. To the best of our knowledge, this is the first case report showing the "tulip-bundle" technique as a rescue endoscopic bleeding control in the esophagus.

  13. Development of Endoscopic Diagnosis and Treatment for Chronic Unilateral Hematuria: 35 Years Experience.

    PubMed

    Tanimoto, Ryuta; Kumon, Hiromi; Bagley, Demetrius H

    2017-04-01

    Chronic unilateral hematuria (CUH) is also called lateralizing essential hematuria, benign essential hematuria, and benign lateralizing hematuria, which was defined as intermittent or continuous gross hematuria that cannot be diagnosed with standard radiology and hematology studies, together with unilateral bloody efflux by cystoscopy. CUH is rare, but sometimes confused with malignancy or life-threatening hemorrhage. Therefore, it can cause considerable anxiety to not only patients but also urologists. For this study, we summarized articles about endoscopic diagnosis and treatment of CUH, and discussed the development of endourology for CUH. We searched articles related to CUH that were indexed in the PubMed database and published in English. Key terms used were "unilateral," "lateralizing," "chronic," "benign," and "idiopathic" hematuria. We found 15 pertinent articles reporting CUH. Endoscopically, CUH can be classified into three categories: discrete lesion, diffuse lesion, or no (unidentified) lesion. Currently, endoscopic techniques for CUH are similar to the techniques for upper tract urothelial carcinoma, using semi-rigid and flexible ureteroscopes with diathermy fulguration or laser ablation for treatment. The overall success rate of endoscopic treatment for CUH, defined as resolution of gross hematuria after treatment, was 93% (190/205). The recurrence rate, defined as recurrent gross hematuria after treatment, was 10% (19/189). Advancements in endoscopic devices and techniques have enabled more accurate and less invasive diagnosis and treatment of CUH. Once CUH is defined, flexible ureteroscopy is the diagnostic and therapeutic technique of choice.

  14. Endoscopy of the upper gastrointestinal tract as a diagnostic tool for children with human immunodeficiency virus infection.

    PubMed

    Miller, T L; McQuinn, L B; Orav, E J

    1997-05-01

    The purpose of this study was to determine the prevalence of upper gastrointestinal tract lesions in children with human immunodeficiency virus (HIV) infection who undergo endoscopy of the upper gastrointestinal tract and to identify important clinical predictors of abnormal endoscopic results. All HIV-infected children who underwent endoscopy and were followed at Children's Hospital, Boston, from January 1985 to August 1994 were studied. The main outcome measure was endoscopic results, which were categorized into observational, histologic, and microbiologic findings. Potential predictors included height, weight, nutritional interventions, HIV disease stage, CD4 T-lymphocyte count, medications, active infections, and indications for endoscopy. Forty-three endoscopies in unique patients are reported. Most children had advanced HIV infection (67% acquired immunodeficiency syndrome, mean CD4 T-lymphocyte count z score = -2.71, weight z score = -2.04). An abnormal endoscopic finding was discovered in 93% of children and confirmed by histologic, microbiologic, or a combination of these studies in 72% of children. Thirty-five percent of children had an opportunistic pathogen identified endoscopically; 65% of these pathogens were previously undiagnosed. Observational findings often were poor indicators of histologic and microbiologic abnormalities. Independent predictors of abnormal histologic findings include younger age at endoscopy (odds ratio (OR) = 1.16 per year, 95% confidence interval (CI) (1.02, 1.33)) and guaiac-negative stools (OR = 16.7, 95% CI (1.92, 142.9)). Independent predictors of finding a pathogen at the time of endoscopy include a greater number of indications for endoscopy (OR = 2.6 per indication, 95% CI (1.3, 5.3)) and diagnosis of acquired immunodeficiency syndrome (OR = 16.4, 95% CI (1.3, 213)). No other gastrointestinal, nutritional, or immunologic parameters were significantly predictive of endoscopic outcomes. Medical management was changed in

  15. Endoscopic Devices for Obesity.

    PubMed

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  16. Patient Response to Endoscopic Therapy for Gastroesophageal Varices Based on Endoscopic Ultrasound Findings.

    PubMed

    Tseng, Yujen; Ma, Lili; Luo, Tiancheng; Zeng, Xiaoqing; Li, Feng; Li, Na; Wei, Yichao; Chen, Shiyao

    2018-04-27

    Gastroesophageal variceal hemorrhage is a common complication of portal hypertension. Endoscopic therapy is currently recommended for preventing gastroesophageal variceal rebleed. However, the rate of variceal rebleed and its associated mortality remain concerning. This study is aimed at differentiating patient response to endoscopic therapy based on endoscopic ultrasound (EUS) findings. One-hundred seventy patients previously treated with repeat endoscopic therapy for secondary prophylaxis were enrolled and classified into two groups based on treatment response. Prior to consolidation therapy, all patients received an EUS examination to observe for extraluminal phenomena. All available follow-up endoscopic examination records were retrieved to validate study results. Of the 170 subjects, 106 were poor responders, while 64 were good responders. The presence of para-gastric, gastric perforating, and esophageal perforating veins was associated with poor patient response (p<0.001). The odds ratio for para-gastric veins was 5.374. Follow-up endoscopic findings for poor responders with incomplete variceal obliteration was closely correlated with the presence of para-gastric veins (p=0.002). The presence of para-gastric veins is a characteristic of poor response to endoscopic therapy for treating gastroesophageal varices. Early identification of this subgroup necessitates a change in course of treatment to improve overall patient outcome.

  17. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    PubMed

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  18. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    PubMed

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  19. An Unusual Cause of Acute Upper Gastrointestinal Bleeding: Acute Esophageal Necrosis

    PubMed Central

    Tokala, Madhusudhan R.; Dhillon, Sonu; Pisoh, Watcoun-Nchinda; Walayat, Saqib; Vanar, Vishwas; Puli, Srinivas R.

    2016-01-01

    Acute esophageal necrosis (AEN), also called “black esophagus,” is a condition characterized by circumferential necrosis of the esophagus with universal distal involvement and variable proximal extension with clear demarcation at the gastroesophageal junction. It is an unusual cause of upper gastrointestinal bleeding and is recognized with distinct and striking mucosal findings on endoscopy. The patients are usually older and are critically ill with shared comorbidities, which include atherosclerotic cardiovascular disease, diabetes mellitus, hypertension, chronic renal insufficiency, and malnutrition. Alcoholism and substance abuse could be seen in younger patients. Patients usually have systemic hypotension along with upper abdominal pain in the background of clinical presentation of hematemesis and melena. The endoscopic findings confirm the diagnosis and biopsy is not always necessary unless clinically indicated in atypical presentations. Herein we present two cases with distinct clinical presentation and discuss the endoscopic findings along with a review of the published literature on the management of AEN. PMID:27642529

  20. Feedback Survey of the Effect, Burden, and Cost of the National Endoscopic Quality Assessment Program during the Past 5 Years in Korea.

    PubMed

    Cho, Yu Kyung; Moon, Jeong Seop; Han, Dong Su; Lee, Yong Chan; Kim, Yeol; Park, Bo Young; Chung, Il-Kwun; Kim, Jin-Oh; Im, Jong Pil; Cha, Jae Myung; Kim, Hyun Gun; Lee, Sang Kil; Lee, Hang Lak; Jang, Jae Young; Kim, Eun Sun; Jung, Yunho; Moon, Chang Mo

    2016-11-01

    In Korea, the nationwide gastric cancer screening program recommends biennial screening for individuals aged 40 years or older by way of either an upper gastrointestinal series or endoscopy. The national endoscopic quality assessment (QA) program began recommending endoscopy in medical institutions in 2009. We aimed to assess the effect, burden, and cost of the QA program from the viewpoint of medical institutions. We surveyed the staff of institutional endoscopic units via e-mail. Staff members from 67 institutions replied. Most doctors were endoscopic specialists. They responded as to whether the QA program raised awareness for endoscopic quality (93%) or improved endoscopic practice (40%). The percentages of responders who reported improvements in the diagnosis of gastric cancer, the qualifications of endoscopists, the quality of facilities and equipment, endoscopic procedure, and endoscopic reprocessing were 69%, 60%, 66%, 82%, and 75%, respectively. Regarding reprocessing, many staff members reported that they had bought new automated endoscopic preprocessors (3%), used more disinfectants (34%), washed endoscopes longer (28%), reduced the number of endoscopies performed to adhere to reprocessing guidelines (9%), and created their own quality education programs (59%). Many responders said they felt that QA was associated with some degree of burden (48%), especially financial burden caused by purchasing new equipment. Reasonable quality standards (45%) and incentives (38%) were considered important to the success of the QA program. Endoscopic quality has improved after 5 years of the mandatory endoscopic QA program.

  1. Endoscopic management of colorectal adenomas.

    PubMed

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.

  2. Endoscopic management of colorectal adenomas

    PubMed Central

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy. PMID:29118553

  3. Endoscopic treatments for portal hypertension.

    PubMed

    Lo, Gin-Ho

    2018-02-01

    Acute esophageal variceal hemorrhage is a dreaded complication of portal hypertension. Its management has evolved rapidly in recent years. Endoscopic therapy is often employed to arrest bleeding varices as well as to prevent early rebleeding. The combination of vasoconstrictor and endoscopic therapy is superior to vasoconstrictor or endoscopic therapy alone for control of acute esophageal variceal hemorrhage. After control of acute variceal bleeding, combination of banding ligation and beta-blockers is generally recommended to prevent variceal rebleeding. To prevent the catastrophic event of acute variceal bleeding, endoscopic banding ligation is an important tool in the prophylaxis of first bleeding. Endoscopic obturation with cyanoacrylate is usually utilized to arrest acute gastric variceal hemorrhage as well as to prevent rebleeding. It can be concluded that endoscopic therapies play a pivotal role in management of portal hypertensive bleeding.

  4. Endoscopic treatment of Roux-en-Y gastric bypass-related gastrocutaneous fistulas using a novel biomaterial.

    PubMed

    Maluf-Filho, Fauze; Hondo, Fabio; Halwan, Bhawna; de Lima, Marcelo Simas; Giordano-Nappi, José Humberto; Sakai, Paulo

    2009-07-01

    Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS, which is a novel biomaterial for the treatment of this complication. A case series of 25 patients. Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS--an acellular fibrogenic matrix biomaterial to help fistula healing. Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Endoscopic application of SurgiSIS-an acellular fibrogenic matrix--is safe and effective for the treatment of gastrocutaneous fistula after RYGB.

  5. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    PubMed

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Principles of endoscopic ear surgery.

    PubMed

    Tarabichi, Muaaz; Kapadia, Mustafa

    2016-10-01

    The aim of this review is to study the rationale, limitations, techniques, and long-term outcomes of endoscopic ear surgery. The article discusses the advantages of endoscopic ear surgery in treating cholesteatoma and how the hidden sites like facial recess, sinus tympani, and anterior epitympanum are easily accessed using the endoscope. Transcanal endoscopic approach allows minimally invasive removal of cholesteatoma with results that compare well to traditional postauricular tympanomastoidectomy.

  7. Successful Emergency Endoscopic Treatment of Gastric Outlet Obstruction due to Gastric Bezoar with Gastric Pneumatosis

    PubMed Central

    Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki

    2017-01-01

    Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP. PMID:29430223

  8. Successful Emergency Endoscopic Treatment of Gastric Outlet Obstruction due to Gastric Bezoar with Gastric Pneumatosis.

    PubMed

    Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki

    2017-01-01

    Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP.

  9. Novel and safer endoscopic cholecystectomy using only a flexible endoscope via single port

    PubMed Central

    Mori, Hirohito; Kobayashi, Nobuya; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Chiyo, Taiga; Ayaki, Maki; Nagase, Takashi; Masaki, Tsutomu

    2016-01-01

    AIM: To apply the laparoscopic and endoscopic cooperative surgery concept, we investigated whether endoscopic cholecystectomy could be performed more safely and rapidly via only 1 port or not. METHODS: Two dogs (11 and 13-mo-old female Beagle) were used in this study. Only 1 blunt port was created, and a flexible endoscope with a tip attachment was inserted between the fundus of gallbladder and liver. After local injection of saline to the gallbladder bed, resection of the gallbladder bed from the liver was performed. After complete resection of the gallbladder bed, the gallbladder was pulled up to resect its neck using the Ring-shaped thread technique. The neck of the gallbladder was cut using scissor forceps. Resected gallbladder was retrieved using endoscopic net forceps via a port. RESULTS: The operation times from general anesthetizing with sevoflurane to finishing the closure of the blunt port site were about 50 min and 60 min respectively. The resection times of gallbladder bed were about 15 min and 13 min respectively without liver injury and bleeding at all. Feed were given just after next day of operation, and they had a good appetite. Two dogs are in good health now and no complications for 1 mo after endoscopic cholecystectomy using only a flexible endoscope via one port. CONCLUSION: We are sure of great feasibility of endoscopic cholecystectomy via single port for human. PMID:27053847

  10. Endoscopic Evacuation of Subdural Collections.

    PubMed

    Boyaci, Suat; Gumustas, Oguzhan Guven; Korkmaz, Serdar; Aksoy, Kaya

    2016-01-01

    Intraoperative use of the endoscope is a hot topic in neurosurgery and it gives broader visualization of critical and hardlyreached areas. Endoscope-assisted surgical approach to chronic subdural haematoma (SDH) is a minimally invasive technique and may give an expansion to the regular method of burr-hole haematoma drainage. Endoscope-assisted haematoma drainage with mini-craniotomy was performed over a 24-month period, and prospectively collected data is reviewed. A total of 10 procedures (8 patients) were performed using the endoscopeassisted technique. Four of them were chronic SDH and six were subacute SDH. Procedures were extended 20 minutes in average because of endoscopic intervention. There was no extra-morbidity through the study as a consequence of endoscopic assessment. Endoscope-assisted techniques can make the operation safe in selected circumstances with improved intraoperative visualization. It may likewise take into consideration the identification and destruction of neo-membranes, septums and solid clots. In addition, the source of bleeding can be easily coagulated. The endoscope-assisted techniques, with all of these features, can alter the pre- and intra-operative decision-making for selected patients.

  11. Treatment of solitary gastric carcinoid tumor by endoscopic polypectomy in a patient with pernicious anemia

    PubMed Central

    Kadikoylu, Gurhan; Yavasoglu, Irfan; Yukselen, Vahit; Ozkara, Esra; Bolaman, Zahit

    2006-01-01

    Type I gastric carcinoid tumors result from hypergastrinemia in 1%-7% of patients with pernicious anemia. We diagnosed pernicious anemia in a 48-year-old female patient with complaint of fatigue for three months. She had no gastrointestinal symptoms. Endoscopic examination ot the upper gastrointestinal tract revealed atrophic gastritis and a polypoid lesion in the corpus of 3-4 mm in size. Endoscopic polypectomy was performed. Histopathological examination of the specimen revealed positive chromogranin A and synaptophysin stainings compatible with the diagnosis of a carcinoid tumor. Serum gastrin level was increased, urinary 5-hydroxyindoleacetic acid was within the normal range. There was no other symptom, sign, or laboratory finding of a carcinoid syndrome in the patient. No metastasis was found with indium-111 octreotide scan, computed tomographies of abdomen and thorax. Type I gastric carcinoid tumors are only rarely solitary and patients with tumors < 1 cm in size may benefit from endoscopic polypectomy. PMID:16830392

  12. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  13. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  14. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  15. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  16. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  17. The AIMS65 Score Is a Useful Predictor of Mortality in Patients with Nonvariceal Upper Gastrointestinal Bleeding: Urgent Endoscopy in Patients with High AIMS65 Scores

    PubMed Central

    Park, Sun Wook; Song, Young Wook; Tak, Dae Hyun; Ahn, Byung Moo; Kang, Sun Hyung; Moon, Hee Seok; Sung, Jae Kyu; Jeong, Hyun Yong

    2015-01-01

    Background/Aims: To validate the AIMS65 score for predicting mortality of patients with nonvariceal upper gastrointestinal bleeding and to evaluate the effectiveness of urgent (<8 hours) endoscopic procedures in patients with high AIMS65 scores. Methods: This was a 5-year single-center, retrospective study. Nonvariceal, upper gastrointestinal bleeding was assessed by using the AIM65 and Rockall scores. Scores for mortality were assessed by calculating the area under the receiver-operating characteristic curve (AUROC). Patients with high AIMS65 scores (≥2) were allocated to either the urgent or non-urgent endoscopic procedure group. In-hospital mortality, success of endoscopic procedure, recurrence of bleeding, admission period, and dose of transfusion were compared between groups. Results: A total of 634 patients were analyzed. The AIMS65 score successfully predicted mortality (AUROC=0.943; 95% confidence interval [CI], 0.876 to 0.99) and was superior to the Rockall score (AUROC=0.856; 95% CI, 0.743 to 0.969) in predicting mortality. The group with high AIMS65 score included 200 patients. The urgent endoscopic procedure group had reduced hospitalization periods (p<0.05) Conclusions: AIMS65 score may be useful in predicting mortality in patients with nonvariceal upper gastrointestinal bleeding. Urgent endoscopic procedures in patients with high scores may be related to reduced hospitalization periods. PMID:26668799

  18. Comparison of Endoscopic and Histological Findings between Typical and Atypical Celiac Disease in Children.

    PubMed

    Semwal, Pooja; Gupta, Raj Kumar; Sharma, Rahul; Garg, Kapil

    2018-04-01

    Celiac disease is a common non-communicable disease with varied presentations. Purpose of this study was to find the duodeno-endoscopic features in celiac disease and to compare duodeno-endoscopic and histological findings between typical and atypical celiac disease in children. Hospital based observational study was conducted at Sir Padampat Mother and Child Health Institute, Jaipur from June 2015 to May 2016. Patients were selected and divided in two groups- typical and atypical celiac disease based upon the presenting symptoms. Upper gastrointestinal endoscopy and duodenal biopsy was performed for serology positive patients. Results were analysed using appropriate statistical test of significance. Out of 101 enrolled patients, 47.5% were male. Age ranged from 1 to 18 years. Study showed that 54.5% were typical and 45.5% were atypical. Patients presenting with atypical symptoms were predominantly of older age group. On endoscopy, scalloping, mosaic pattern, reduced fold height and absent fold height; and in histology, advanced Marsh stage were significantly higher in the typical group. Awareness of atypical presentations as well as duodeno-endoscopic features may have considerable practical importance for the diagnosis of celiac disease in children. Scalloping, mosaic pattern, reduced fold height and nodularity are main endoscopic markers of celiac disease in children. Endoscopic markers of duodenal mucosa may be important in early diagnosis of celiac disease, in children subjected to endoscopy for atypical presentations or indication other than suspected celiac disease.

  19. Endoscopic submucosal dissection for locally recurrent colorectal lesions after previous endoscopic mucosal resection.

    PubMed

    Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng

    2009-02-01

    The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.

  20. Endoscopic findings in patients presenting with dysphagia: analysis of a national endoscopy database.

    PubMed

    Krishnamurthy, Chaya; Hilden, Kristen; Peterson, Kathryn A; Mattek, Nora; Adler, Douglas G; Fang, John C

    2012-03-01

    Dysphagia is a common problem and an indication for upper endoscopy. There is no data on the frequency of the different endoscopic findings and whether they change according to demographics or by single versus repeat endoscopy. To determine the prevalence of endoscopic findings in patients with dysphagia and whether findings differ in regard to age, gender, ethnicity, and repeat procedure. This was a retrospective study using a national endoscopic database (CORI). A total of 30,377 patients underwent esophagogastroduodenoscopy (EGD) for dysphagia of which 4,202 patients were repeat endoscopies. Overall frequency of endoscopic findings was determined by gender, age, ethnicity, and single vs. repeat procedures. Esophageal stricture was the most common finding followed by normal, esophagitis/ulcer (EU), Schatzki ring (SR), esophageal food impaction (EFI), and suspected malignancy. Males were more likely to undergo repeat endoscopies and more likely to have stricture, EU, EFI, and suspected malignancy (P = 0.001). Patients 60 years or older had a higher prevalence of stricture, EU, SR, and suspected malignancy (P < 0.0001). Esophageal stricture was most common in white non-Hispanic patients compared to other ethnic groups. In patients undergoing repeat EGD, stricture, SR, EFI, and suspected malignancy were more common (P < 0.0001). The prevalence of endoscopic findings differs significantly by gender, age, and repeat procedure. The most common findings in descending order were stricture, normal, EU, SR, EFI, and suspected malignancy. For patients undergoing a repeat procedure, normal and EU were less common and all other abnormal findings were significantly more common.

  1. Endoscopic management of sinonasal hemangiopericytoma.

    PubMed

    Tessema, Belachew; Eloy, Jean Anderson; Folbe, Adam J; Anstead, Amy S; Mirani, Neena M; Jourdy, Deya N; Joudy, Deya N; Ruiz, Jose W; Casiano, Roy R

    2012-03-01

    Sinonasal hemangiopericytomas (SNHPCs) are rare perivascular tumors with low-grade malignant potential. Traditionally, these tumors have been treated with open approaches such as lateral rhinotomy, Caldwell-Luc, or transfacial approaches. Increased experience with endoscopic management of benign and malignant sinonasal tumors has led to a shift in management of SNHPC. The authors present their experience in the largest series of patients with SNHPC managed endoscopically. Case series at a tertiary care medical center. A retrospective chart review of all patients undergoing endoscopic management of SNHPC at the University of Miami between 1999 and 2008 was conducted. All endoscopic resections were performed with curative intent. Twelve patients with the diagnosis of SNHPC were treated endoscopically. Mean age was 62.5 years (range, 51-83 years). There were 6 men and 6 women. The mean follow-up was 41 months (range, 15-91 months). Seven (58.3%) presented with nasal obstruction, whereas 4 (41.6%) had epistaxis as their initial presenting symptom. Preoperative angiography or embolization was not performed in any case. Mean estimated blood loss was 630 mL (range, 100-1500 mL). Six patients underwent endonasal endoscopic anterior skull base resection; 4 had complete endoscopic resection all with negative margins. None underwent postoperative adjuvant treatment. No recurrence or metastatic disease was observed in this patient population. Endoscopic management of SNHPC is a feasible approach and did not compromise outcomes in this experience. In this series, familiarity with advance endoscopic sinus surgery was necessary to manage these patients. Postoperative adjuvant therapy was not necessary in this cohort.

  2. Management of overt upper gastrointestinal bleeding in a low resource setting: a real world report from Nigeria.

    PubMed

    Alatise, Olusegun I; Aderibigbe, Adeniyi S; Adisa, Adewale O; Adekanle, Olusegun; Agbakwuru, Augustine E; Arigbabu, Anthony O

    2014-12-10

    Upper gastrointestinal bleeding (UGIB) remains a common medical problem worldwide that has significant associated morbidity, mortality, and health care resource use. This study outlines the aetiology, clinical presentation, and treatment outcomes of patients with UGIB in a Nigerian low resource health facility. This was a descriptive study of consecutive patients who underwent upper gastrointestinal (GI) endoscopy for upper GI bleeding in the endoscopy unit of the Obafemi Awolowo University Teaching Hospital Complex, Ile-Ife, Osun State, Nigeria from January 2007 to December 2013. During the study period, 287 (12.4%) of 2,320 patients who underwent upper GI endoscopies had UGIB. Of these, 206 (72.0%) patients were males and their ages ranged from 3 to 100 years with a median age of 49 years. The main clinical presentation included passage of melaena stool in 268 (93.4%) of individuals, 173 (60.3%) had haematemesis, 110 (38.3%) had haematochezia, and 161 (56.1%) were dizzy at presentation. Observed in 88 (30.6%) of UGIB patients, duodenal ulcer was the most common cause, followed by varices [52 (18.1%)] and gastritis [51 (17.1%)]. For variceal bleeding, 15 (28.8%) and 21 (40.4%) of patients had injection sclerotherapy and variceal band ligation, respectively. The overall rebleeding rate for endoscopic therapy for varices was 16.7%. For patients with ulcers, only 42 of 55 who had Forrest grade Ia to IIb ulcers were offered endoscopic therapy. Endoscopic therapy was áin 90.5% of the cases. No rebleeding followed endoscopic therapy for the ulcers. The obtained Rockall scores ranged from 2 to 10 and the median was 5.0. Of all patients, 92.7% had medium or high risk scores. An increase in Rockall score was significantly associated with length of hospital stay and mortality (p < 0.001). The overall mortality rate was 5.9% (17 patients). Endoscopic therapy for UGIB in a resource-poor setting such as Nigeria is feasible, significantly reduces morbidity and mortality

  3. Endoscopic therapy of neoplasia related to Barrett's esophagus and endoscopic palliation of esophageal cancer.

    PubMed

    Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K

    2013-04-01

    Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.

  4. Diagnosis and management of nonvariceal upper gastrointestinal hemorrhage: European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    PubMed

    Gralnek, Ian M; Dumonceau, Jean-Marc; Kuipers, Ernst J; Lanas, Angel; Sanders, David S; Kurien, Matthew; Rotondano, Gianluca; Hucl, Tomas; Dinis-Ribeiro, Mario; Marmo, Riccardo; Racz, Istvan; Arezzo, Alberto; Hoffmann, Ralf-Thorsten; Lesur, Gilles; de Franchis, Roberto; Aabakken, Lars; Veitch, Andrew; Radaelli, Franco; Salgueiro, Paulo; Cardoso, Ricardo; Maia, Luís; Zullo, Angelo; Cipolletta, Livio; Hassan, Cesare

    2015-10-01

    or ongoing active UGIH. In selected patients, pre-endoscopic infusion of erythromycin significantly improves endoscopic visualization, reduces the need for second-look endoscopy, decreases the number of units of blood transfused, and reduces duration of hospital stay (strong recommendation, high quality evidence). MR7. Following hemodynamic resuscitation, ESGE recommends early (≤ 24 hours) upper GI endoscopy. Very early (< 12 hours) upper GI endoscopy may be considered in patients with high risk clinical features, namely: hemodynamic instability (tachycardia, hypotension) that persists despite ongoing attempts at volume resuscitation; in-hospital bloody emesis/nasogastric aspirate; or contraindication to the interruption of anticoagulation (strong recommendation, moderate quality evidence). MR8. ESGE recommends that peptic ulcers with spurting or oozing bleeding (Forrest classification Ia and Ib, respectively) or with a nonbleeding visible vessel (Forrest classification IIa) receive endoscopic hemostasis because these lesions are at high risk for persistent bleeding or rebleeding (strong recommendation, high quality evidence). MR9. ESGE recommends that peptic ulcers with an adherent clot (Forrest classification IIb) be considered for endoscopic clot removal. Once the clot is removed, any identified underlying active bleeding (Forrest classification Ia or Ib) or nonbleeding visible vessel (Forrest classification IIa) should receive endoscopic hemostasis (weak recommendation, moderate quality evidence). MR10. In patients with peptic ulcers having a flat pigmented spot (Forrest classification IIc) or clean base (Forrest classification III), ESGE does not recommend endoscopic hemostasis as these stigmata present a low risk of recurrent bleeding. In selected clinical settings, these patients may be discharged to home on standard PPI therapy, e. g., oral PPI once-daily (strong recommendation, moderate quality evidence). MR11. ESGE recommends that epinephrine

  5. Fully-covered metal stents with endoscopic suturing vs. partially-covered metal stents for benign upper gastrointestinal diseases: a comparative study

    PubMed Central

    Ngamruengphong, Saowanee; Sharaiha, Reem; Sethi, Amrita; Siddiqui, Ali; DiMaio, Christopher J.; Gonzalez, Susana; Rogart, Jason; Jagroop, Sophia; Widmer, Jessica; Im, Jennifer; Hasan, Raza Abbas; Laique, Sobia; Gonda, Tamas; Poneros, John; Desai, Amit; Wong, Katherine; Villgran, Vipin; Brewer Gutierrez, Olaya; Bukhari, Majidah; Chen, Yen-I; Hernaez, Ruben; Hanada, Yuri; Sanaei, Omid; Agarwal, Amol; Kalloo, Anthony N.; Kumbhari, Vivek; Singh, Vikesh; Khashab, Mouen A.

    2018-01-01

    Background and study aims  Self-expandable metallic stents (SEMS) have been increasingly used in benign conditions (e. g. strictures, fistulas, leaks, and perforations). Fully covered SEMS (FSEMS) were introduced to avoid undesirable consequences of partially covered SEMS (PSEMS), but come with higher risk of stent migration. Endoscopic suturing (ES) for stent fixation has been shown to reduce migration of FSEMS. Our aim was to compare the outcomes of FSEMS with ES (FS/ES) versus PSEMS in patients with benign upper gastrointestinal conditions. Patients and methods  We retrospectively identified all patients who underwent stent placement for benign gastrointestinal conditions at seven US tertiary-care centers. Patients were divided into two groups: FSEMS with ES (FS/ES group) and PSEMS (PSEMS group). Clinical outcomes between the two groups were compared. Results  A total of 74 (FS/ES 46, PSEMS 28) patients were included. On multivariable analysis, there was no significant difference in rate of stent migration between FS/ES (43 %) and PSEMS (15 %) (adjusted odds ratio 0.56; 95 % CI 0.15 – 2.00). Clinical success was similar [68 % vs. 64 %; P  = 0.81]. Rate of adverse events (AEs) was higher in PSEMS group [13 (46 %) vs. 10 (21 %); P  = 0.03). Difficult stent removal was higher in the PSEMS group (n = 5;17 %) vs. 0 % in the FS/ES group; P  = 0.005. Conclusions  The proportion of stent migration of FS/ES and PSEMS are similar. Rates of other stent-related AEs were higher in the PSEMS group. PSEMS was associated with tissue ingrowth or overgrowth leading to difficult stent removal, and secondary stricture formation. Thus, FSEMS with ES for stent fixation may be the preferred modality over PSEMS for the treatment of benign upper gastrointestinal conditions. PMID:29404384

  6. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    PubMed

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  7. Endoscopic agger nasi type Draf IIb treatment for frontal sinus lesions.

    PubMed

    Shi, Linggai; Liu, Jun; Ma, Jiqing; Liu, Fei; Wang, Guangke

    2016-09-01

    Treatment of frontal sinus using surgery is complicated owing to the complex anatomical structure of the sinus region. The aim of the present study was to investigate the efficacy and safety of Draf IIb endoscopic frontal sinus surgery treatment for frontal sinus lesions using the agger nasi approach on 19 patients (28 left or and right nasal cavities). A 10-12 mm excision of the upper frontal maxilla was performed for endoscopic resection between the middle turbinate and lateral nasal wall. No serious complications in frontal sinus surgery treatment for the removal of the frontal sinus were observed. Patients were followed up after surgery for 6-36 months. Chronic sinusitis and nasal polyps were identified in 10 cases (19 left or and right nasal cavities; disease control, 15 left or and right nasal cavities; and disease partial control, 4 left or and right nasal cavities). Frontal sinus inverted papilloma was observed in 9 cases (9 left or and right nasal cavities). Frontal sinus inverted papilloma were successfully treated in 8 cases, and 1 case of recurrence was observed. In conclusion, the nasal endoscopic Draf IIb agger nasi approach is a minimally invasive treatment for frontal sinus lesions. This surgical procedure is safe and less complicated and may be applied in the clinic.

  8. Anatomic optical coherence tomography for dynamic imaging of the upper airway

    NASA Astrophysics Data System (ADS)

    Bu, Ruofei; Balakrishnan, Santosh; Iftimia, Nicusor; Price, Hillel; Zdanski, Carlton; Oldenburg, Amy L.

    2017-03-01

    To aid in diagnosis and treatment of upper airway obstructive disorders (UAOD), we propose anatomic Optical Coherence Tomography (aOCT) for endoscopic imaging of the upper airway lumen with high speed and resolution. aOCT and CT scans are performed sequentially on in vivo swine to compare dynamic airway imaging data. The aOCT system is capable of capturing the dynamic deformation of the airway during respiration. This may lead to methods for airway elastography and aid in our understanding of dynamic collapse in UAOD.

  9. Transvaginal endoscopic partial gastrectomy in porcine models: the role of an extra endoscope for gastric control.

    PubMed

    Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou

    2008-12-01

    Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem

  10. Building an endoscopic ear surgery program.

    PubMed

    Golub, Justin S

    2016-10-01

    This article discusses background, operative details, and outcomes of endoscopic ear surgery. This information will be helpful for those establishing a new program. Endoscopic ear surgery is growing in popularity. The ideal benefit is in totally transcanal access that would otherwise require a larger incision. The endoscope carries a number of advantages over the microscope, as well as some disadvantages. Several key maneuvers can minimize disadvantages. There is a paucity of studies directly comparing outcomes between endoscopic and microscopic approaches for the same procedure. The endoscope is gaining acceptance as a tool for treating otologic diseases. For interested surgeons, this article can help bridge the transition from microscopic to totally transcanal endoscopic ear surgery for appropriate disease.

  11. Correlation between endoscopic forceps biopsies and endoscopic mucosal resection with endoscopic ultrasound in patients with Barrett's esophagus with high-grade dysplasia and early cancer.

    PubMed

    Thota, Prashanthi N; Sada, Alaa; Sanaka, Madhusudhan R; Jang, Sunguk; Lopez, Rocio; Goldblum, John R; Liu, Xiuli; Dumot, John A; Vargo, John; Zuccarro, Gregory

    2017-03-01

    Patients with Barrett's esophagus (BE) and high-grade dysplasia (HGD) or intramucosal cancer (IMC) on endoscopic forceps biopsies are referred to endoscopic therapy even though forceps biopsies do not reflect the disease extent accurately. Endoscopic mucosal resection (EMR) and endoscopic ultrasound (EUS) are frequently used for staging prior to endoscopic therapy. Our aims were to evaluate: (1) if endoscopic forceps biopsies correlated with EMR histology in these patients; (2) the utility of EUS compared to EMR; and (3) if accuracy of EUS varied based on grade of differentiation of tumor. This is a retrospective review of patients referred to endoscopic therapy of BE with HGD or early esophageal adenocarcinoma (EAC) who underwent EMR from 2006 to 2011. Age, race, sex, length of Barrett's segment, hiatal hernia size, number of endoscopies and biopsy results and EUS findings were abstracted. A total of 151 patients underwent EMR. In 50 % (75/151) of patients, EMR histology was consistent with endoscopic forceps biopsy findings. EMR resulted in change in diagnosis with upstaging in 21 % (32/151) and downstaging in 29 % (44/151). In patients with HGD on EMR, EUS staging was T0 in 74.1 % (23/31) but upstaged in 25.8 % (8/31). In patients with IMC on EMR, EUS findings were T1a in 23.6 % (9/38), upstaged in 18.4 % (7/38) and downstaged in 57.8 % (22/38). EUS accurately identified EMR histology in all submucosal cancers. Grade of differentiation was reported in 24 cancers on EMR histology. There was no correlation between grade and EUS staging. EUS is of limited utility in accurate staging of BE patients with HGD or early EAC. Endoscopic forceps biopsy correlated with EMR findings in only 50 % of patients. Irrespective of the endoscopic forceps biopsy results, all BE patients with visible lesions should be referred to EMR.

  12. Suprachiasmatic translamina terminalis corridor used in endoscopic endonasal approach for resecting third ventricular craniopharyngioma.

    PubMed

    Gu, Ye; Zhang, Xiaobiao; Hu, Fan; Yu, Yong; Xie, Tao; Sun, Chongjing; Li, Wensheng

    2015-05-01

    The translamina terminalis corridor was used in the transcranial anterior route to treat third ventricular craniopharyngioma (TVC), which presents a challenge to neurosurgeons. The endoscopic endonasal approach (EEA) has recently been used to treat craniopharyngiomas. However, there are few reports of the EEA being used to treat TVC. The authors' novel surgical approach of treating selected TVC by the endoscopic endonasal route via the suprachiasmatic translamina terminalis (STLT) corridor is described. In this single-center study, the EEA via the STLT corridor was used to resect TVC with great upper and anterior extension causing bulged lamina terminalis, and TVC with a residual upper compartment, after routine infrachiasmatic transmetastalk corridor resection. The STLT corridor was used in 3 patients. Gross-total resection was achieved in all cases. One patient achieved visual improvement, and the other 2 patients showed partial visual improvement. Leakage of CSF occurred in 1 patient. Postoperative hormone replacement therapy was required in all patients. The STLT corridor is a complementary minimally invasive corridor used in the EEA for treating selected TVC. The STLT alone or combined with infrachiasmatic transmetastalk corridors should be selected depending on the size of suprachiasmatic and infrachiasmatic space.

  13. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  14. [The development of endoscope workstation].

    PubMed

    Qi, L; Qi, L; Qiou, Q J; Yu, Q L

    2001-01-01

    This paper introduces an endoscope workstation, which solved the weak points of multimedia endoscope database used by most hospitals. The endoscope workstation was built on pedal-switch and NTFS file system. This paper also Introduces how to make program optimal and quick inputting. The workstation has promoted the efficiency of the doctor's operation.

  15. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study).

    PubMed

    van den Broek, Frank J C; de Graaf, Eelco J R; Dijkgraaf, Marcel G W; Reitsma, Johannes B; Haringsma, Jelle; Timmer, Robin; Weusten, Bas L A M; Gerhards, Michael F; Consten, Esther C J; Schwartz, Matthijs P; Boom, Maarten J; Derksen, Erik J; Bijnen, A Bart; Davids, Paul H P; Hoff, Christiaan; van Dullemen, Hendrik M; Heine, G Dimitri N; van der Linde, Klaas; Jansen, Jeroen M; Mallant-Hent, Rosalie C H; Breumelhof, Ronald; Geldof, Han; Hardwick, James C H; Doornebosch, Pascal G; Depla, Annekatrien C T M; Ernst, Miranda F; van Munster, Ivo P; de Hingh, Ignace H J T; Schoon, Erik J; Bemelman, Willem A; Fockens, Paul; Dekker, Evelien

    2009-03-13

    Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications.The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma > or = 3 cm, located between 1-15 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane in a piecemeal fashion, and patients will be discharged from the hospital. Residual adenoma that is visible during the first surveillance endoscopy at 3 months will be removed endoscopically in both treatment strategies and is considered as part of the primary treatment. Primary outcome measure is the proportion of patients with recurrence after 3 months. Secondary outcome measures are: 2) number of days not spent in hospital from initial treatment until 2 years afterwards; 3) major and minor morbidity; 4) disease specific and general quality of life; 5) anorectal function; 6) health care utilization and costs. A cost-effectiveness and cost-utility analysis of EMR against TEM for large rectal adenomas will be performed from a societal perspective with respectively the costs per recurrence free patient and the cost per quality adjusted life year as outcome measures. Based on comparable recurrence rates for TEM and EMR of 3.3% and considering an upper-limit of 10

  16. Endoscopic resection of subepithelial tumors

    PubMed Central

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-01-01

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods. PMID:25512768

  17. Endoscopic resection of subepithelial tumors.

    PubMed

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-12-16

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.

  18. [Histopathological Study of the Relationship between Lymphoid Follicles and Different Endoscopic Types of Nodular Gastritis].

    PubMed

    Nagata, Takuo; Ishitake, Hisahito; Shimamoto, Fumio; Tamura, Tadamasa; Matsumura, Kazunori; Sumii, Masaharu; Nakai, Shirou

    2014-11-01

    Nodular gastritis is characterized histologically by hyperplasia and enlargement of lymphoid follicles in the lamina propria. With the objective of elucidating the relationship between different endoscopic types of nodular gastritis and lymphoid follicles, distributions of lymphoid follicles in the lamina propria were investigated in young gastric cancer patients with nodular gastritis. For the study, whole-mucosal step sectioning of each resected stomach was performed, the densities of lymphoid follicles of all specimens were measured microscopically, and the horizontal and depth distributions were calculated. For assessment in the horizontal direction, density distribution diagrams of lymphoid follicles were created. For assessment in the depth direction, the different endoscopic types of nodular gastritis were compared in the five different analysis sites. In the assessment of the horizontal distribution, no characteristic distribution tendencies were observed in either the granular type group or the scattered type group; however, it was found that areas with relatively high densities of lymphoid follicles generally coincided with the areas where nodular gastritis was observed endoscopically. These results suggested that hyperplasia and aggregation of lymphoid follicles in the lamina propria are involved at the sites where nodular gastritis is observed endoscopically. In the assessment of the depth distribution, lymphoid follicles tended to be more unevenly distributed in the upper lamina propria in the granular type group than in the scattered type at the three different analysis sites where nodular gastritis was observed endoscopically. These results suggested the possibility of a granular type characteristic.

  19. Diagnosis and management of upper gastrointestinal bleeding in children.

    PubMed

    Owensby, Susan; Taylor, Kellee; Wilkins, Thad

    2015-01-01

    Upper gastrointestinal bleeding is an uncommon but potentially serious, life-threatening condition in children. Rapid assessment, stabilization, and resuscitation should precede all diagnostic modalities in unstable children. The diagnostic approach includes history, examination, laboratory evaluation, endoscopic procedures, and imaging studies. The clinician needs to determine carefully whether any blood or possible blood reported by a child or adult represents true upper gastrointestinal bleeding because most children with true upper gastrointestinal bleeding require admission to a pediatric intensive care unit. After the diagnosis is established, the physician should start a proton pump inhibitor or histamine 2 receptor antagonist in children with upper gastrointestinal bleeding. Consideration should also be given to the initiation of vasoactive drugs in all children in whom variceal bleeding is suspected. An endoscopy should be performed once the child is hemodynamically stable. © Copyright 2015 by the American Board of Family Medicine.

  20. Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection

    PubMed Central

    Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace

    2016-01-01

    Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID

  1. Association of clinical signs with endoscopic findings in horses with nasopharyngeal cicatrix syndrome: 118 cases (2003-2008).

    PubMed

    Norman, Tracy E; Chaffin, M Keith; Bisset, Wesley T; Thompson, James A

    2012-03-15

    To characterize the associations between clinical signs of nasopharyngeal cicatrix syndrome (NCS) and endoscopic findings in horses. Retrospective, case-control study. 239 horses (118 case horses and 121 control horses). Medical records of horses that had an endoscopic evaluation of the upper airway performed between January 2003 and December 2008 were reviewed. Clinical signs and the appearance and anatomic locations of lesions identified during endoscopic evaluation were reviewed and recorded for each horse. The associations between clinical signs and endoscopic findings were evaluated by the use of a prospective logistic model that used a Bayesian method for inference and was implemented by a Markov chain Monte Carlo method. Nasal discharge was associated with acute inflammation of the pharynx and larynx. Exercise intolerance was associated with circumferential pharyngeal lesions. Respiratory noise was associated with chronic scarring of the pharynx, a combination of pharyngeal and laryngeal scarring, and circumferential scarring of the pharynx. Respiratory distress was associated with acute inflammation of all portions of the airway, especially when there was preexisting scarring and narrowing of the airway by ≥ 50%. Cough did not have any significant association with NCS, compared with results in control horses. Associations between the endoscopic appearance of NCS lesions and relevant clinical signs will help practitioners identify horses with NCS and allow them to select appropriate treatment.

  2. Endoscopic techniques in aesthetic plastic surgery.

    PubMed

    McCain, L A; Jones, G

    1995-01-01

    There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.

  3. Incidence of Helicobacter pylori in operatively managed acute nonvariceal upper gastrointestinal bleeding.

    PubMed

    Callicutt, C S; Behrman, S W

    2001-01-01

    Helicobacter pylori is a known contributor to ulcerogenesis and nonvariceal acute upper gastrointestinal hemorrhage. Its incidence in operatively managed patients with upper gastrointestinal hemorrhage is ill defined. Patients undergoing surgery for upper gastrointestinal hemorrhage secondary to gastroduodenal ulceration between 1993 and 1998 at the University of Tennessee were retrospectively reviewed. Factors examined included age, nonsteroidal drug use, endoscopic intervention, urgency of operation, and H. pylori status confirmed by histologic examination. Forty-two patients had surgery with three excluded because of a lack of histologic evaluation. The site of bleeding was gastric in 23 and duodenal in 14. H. pylori infection was present in nine (39.1%) gastric and 11 (68.7%) duodenal ulcers. The incidence of H. pylori infection was reduced in those over 60 years of age (28.6%). Endoscopy was performed in all patients, but only two had biopsies for assessment of H. pylori. Operative morbidity was 17.9% and mortality was 5.1%. No patient had rebleeding following surgery. The incidence of H. pylori in this population is less than that reported in uncomplicated ulcer disease. Those older than 60 tended to be H. pylori negative. Endoscopic assessment for H. pylori was infrequent. Traditional indications for surgical intervention in ulcer hemorrhage should not be altered based on H. pylori status.

  4. Endoscopic approaches to treatment of achalasia

    PubMed Central

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707

  5. Comparison of Complications Rates in Endoscopic Surgery Performed by a Clinical Assistant vs. An Experienced Endoscopic Surgeon

    PubMed Central

    Singhi, Aditi

    2009-01-01

    Study Objectives: (a) To find out the actual incidence of complications during endoscopic surgeries. (b) Comparison of complication rate between an experienced laparoscopic surgeon (> 10 years of experience in endoscopic surgery) and a clinical assistant (> 3 years of experience in endoscopic surgery). (c) How to manage complications in endoscopic surgery. (d) Concrete suggestions to reduce the complication rate. Design: Retrospective study (Canadian Task Force classification ii-2). Setting: Tertiary gynecologic endoscopic unit. Patients: A total of 3204 cases of gynecologic endoscopic surgery out of which 2001 were laparoscopic and 1203 were hysteroscopic surgeries. Interventions: Laparoscopic and hysteroscopic gynecologic surgeries in indicated cases. Measurements and Main Results: The study was carried out between April 2003 and October 2007 at a referral center for endoscopic surgery. A total of 3204 cases of gynecologic endoscopic surgery were studied. There were five significant complications in laparoscopic surgeries and four significant complications in hysteroscopic surgeries seen in four years and six months. All the complications could be managed with no mortality. Conversion to laparotomy was needed in eight cases of laparoscopic surgeries and none in hysteroscopic surgeries. Conclusion: The risk of complication reduces with the experience in endoscopic surgery. However, the proper grooming of a novice in experienced hands, for a sufficient period of time, can minimize the complication rate in the initial learning phase. The complication may be utilized as a stepping-stone to overcome any given situation without panic, but with adequate safety. PMID:22442510

  6. Endoscopic mucosal resection for early gastric cancer. A case report.

    PubMed

    Gheorghe, Cristian; Sporea, Ioan; Becheanu, Gabriel; Gheorghe, Liana

    2002-03-01

    European experience in endoscopic mucosal resection (EMR) for early gastric cancer is still relatively low, since early stomach cancer is diagnosed at a much lower rate in Europe than in Japan and generally operable patients are referred to surgery for radical resection. Endoscopic mucosal resection or mucosectomy was developed as a promising technology to diagnose and treat mucosal lesions in the esophagus, stomach and colon. In contrast to surgical resection, EMR allows "early cancers" to be removed with a minimal cost, morbidity and mortality. We present the case of a patient with hepatic cirrhosis incidentally diagnosed with an elevated-type IIa early gastric cancer. Echoendoscopy was performed in order to assess the depth of invasion into the gastric wall confirming the only mucosal involvement. We performed an EMR using "cup and suction" method. After the procedure, the patient experienced an acute upper gastrointestinal bleeding from the ulcer bed requiring argon plasma coagulation. The histopathological examination confirmed an early cancer, without involvement of muscularis mucosae. The patient has had an uneventful evolution being well at six months after the procedure

  7. [Endoscopic extraction of gallbladder calculi].

    PubMed

    Kühner, W; Frimberger, E; Ottenjann, R

    1984-06-29

    Endoscopic extraction of gallbladder stones were performed, as far as we know for the first time, in three patients with combined choledochocystolithiasis. Following endoscopic papillotomy (EPT) and subsequent mechanical lithotripsy of multiple choledochal concrements measuring up to 3 cm the gallbladder stones were successfully extracted with a Dormia basket through the cystic duct. The patients have remained free of complications after the endoscopic intervention.

  8. Anatomic Optical Coherence Tomography of Upper Airways

    NASA Astrophysics Data System (ADS)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  9. Endoscopic findings following retroperitoneal pancreas transplantation.

    PubMed

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Cerebral Arterial Gas Embolism During Upper Endoscopy.

    PubMed

    Eoh, Eun J; Derrick, Bruce; Moon, Richard

    2015-09-15

    Arterial gas embolism can be caused by direct entry of gas into systemic arteries or indirectly by venous-to-arterial shunting. Although arterial gas embolism is rare, most documented cases are iatrogenic, resulting from the entry of gas during procedures that involve direct vascular cannulation or intracavitary air insufflation. Of the 18 identified case reports of air embolism during endoscopy, 11 cases describe findings of cerebral arterial gas embolism during upper endoscopy. Only 1 of these occurred during endoscopic balloon dilation of an esophageal stricture. We report a rare case of cerebral arterial gas embolism in a 64-year-old woman, which occurred during endoscopic dilation of an esophageal stricture and was subsequently treated with hyperbaric oxygen therapy. In this case report, we explore the possible etiologies, clinical workup, and therapeutic management of cerebral artery gas embolisms. Hyperbaric oxygen therapy is the treatment of choice for cerebral arterial gas embolism, with earlier treatments resulting in better outcomes.

  11. Clinical significance of duodenal lymphangiectasia incidentally found during routine upper gastrointestinal endoscopy.

    PubMed

    Kim, J H; Bak, Y T; Kim, J S; Seol, S Y; Shin, B K; Kim, H K

    2009-06-01

    Although duodenal lymphangiectasia in individuals without clinical evidence of malabsorption has been reported, the prevalence and clinical significance in this situation are not yet known. The aim of this study was to evaluate the prevalence and clinical significance of incidentally found duodenal lymphangiectasia. A retrospective review of medical records was undertaken for consecutive patients who had undergone diagnostic upper endoscopy between January 2005 and June 2006. A prospective study was then performed in consecutive individuals undergoing routine upper endoscopy for health examination between July 2006 to October 2006. Endoscopic features of duodenal lymphangiectasia were classified into three types: (1) multiple scattered pinpoint white spots; (2) diffuse prominent villi with whitish-discolored tips; and (3) focal small whitish macule or nodule. The histologic grade of duodenal lymphangiectasia was classified according to the depth and severity of lymphatic duct dilatations. Prevalence and clinical data of incidentally found duodenal lymphangiectasia were evaluated in the retrospective and prospective studies. Among 1866 retrospective cases, duodenal lymphangiectasia was endoscopically suspected in 59 cases (3.2%), and histologically confirmed in 35 cases (1.9%). No clinical evidence of malabsorption was noted in the duodenal lymphangiectasia cases. The "scattered pinpoint white spots" type was the most frequently found endoscopic feature (40.0%). Duodenal lymphangiectasia was persistent in seven of 10 individuals who underwent repeat endoscopy after a median of 12 months. Among 134 prospective cases, duodenal lymphangiectasia was histologically confirmed in 12 cases (8.9%). There was no significant clinical difference between groups with and without duodenal lymphangiectasia. Lymphatic duct dilatation was histologically more severe in the "focal small whitish macule or nodule" type than in the other types. Duodenal lymphangiectasia without clinical

  12. Endoscopic submucosal dissection using flexknife.

    PubMed

    Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao

    2006-01-01

    Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.

  13. Endoscopic management of pancreatic fluid collections-revisited

    PubMed Central

    Nabi, Zaheer; Basha, Jahangeer; Reddy, D Nageshwar

    2017-01-01

    The development of pancreatic fluid collections (PFC) is one of the most common complications of acute severe pancreatitis. Most of the acute pancreatic fluid collections resolve and do not require endoscopic drainage. However, a substantial proportion of acute necrotic collections get walled off and may require drainage. Endoscopic drainage of PFC is now the preferred mode of drainage due to reduced morbidity and mortality as compared to surgical or percutaneous drainage. With the introduction of new metal stents, the efficiency of endoscopic drainage has improved and the task of direct endoscopic necrosectomy has become easier. The requirement of re-intervention is less with new metal stents as compared to plastic stents. However, endoscopic drainage is not free of adverse events. Severe complications including bleeding, perforation, sepsis and embolism have been described with endoscopic approach to PFC. Therefore, the endoscopic management of PFC is a multidisciplinary affair and involves interventional radiologists as well as GI surgeons to deal with unplanned adverse events and failures. In this review we discuss the recent advances and controversies in the endoscopic management of PFC. PMID:28487603

  14. Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures

    PubMed Central

    Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit

    2017-01-01

    Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906

  15. [Endoscopic full-thickness resection].

    PubMed

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  16. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  17. Endoscopic palliation of advanced esophageal cancer

    PubMed Central

    Mocanu, A; Bârla, R; Hoara, P; Constantinoiu, S

    2015-01-01

    Esophageal cancer represents one of the most aggressive digestive tumors, with a survival rate at 5 years of only 10%. Globally, during the last three decades, there has been an increasing incidence of the esophageal cancer, approx. 400,000 new esophageal cancers being currently diagnosed annually. This represents the eighth leading cause of cancer incidence and the sixth leading cause of cancer death overall. Taking into account the population’s global aging and thus, the increase in the number of patients who will not bear surgery, PCT and radiation, or the fact that they do not want it especially because of deficiencies and associated pathology, the endoscopic ablative techniques with palliation purposes represent the alternative. If we refer to the Western Europe countries and North America, we notice an increase of esophageal adenocarcinoma rate versus squamous cancer. As for the Asian region, referring in particular to China and Japan, 9 out of 10 esophageal cancers are squamous cell carcinomas. For at least half of the patients with EC (esophageal cancer) there is no hope of healing because of the advanced regional malignant invasion (T3-4, N+, M+) with no chemo and radiotherapy response, poor preoperative patients’ conditions or systemic metastasis. The low life expectancy does not justify the risky medical procedures, the goal of the therapy consisting in the improvement of the quality of life by eliminating dysphagia (reestablishing oral feeding) which represents the most common complication of EC, the respiratory tract complication caused by eso-tracheal fistulas or by eliminating chest pain. To treat dysphagia, which is the main target of palliation, combined methods like endoscopic, chemo and radio-therapy, can be used, each one with indications, benefits and risks. Abbreviations: SEPS = self expanding plastic stent, SREMS = self expanding metal stent, EBRT = Endoscopic brachy radiotherapy, EUS = Ultra sound endoscopy, CT = Computer tomograph, UGE

  18. Endoscopic full-thickness resection: Current status

    PubMed Central

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-01-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices. PMID:26309354

  19. Endoscopic full-thickness resection: Current status.

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  20. Clinical relevance of endoscopic assessment of inflammation in ulcerative colitis: Can endoscopic evaluation predict outcomes?

    PubMed Central

    Mohammed, Noor; Subramanian, Venkataraman

    2016-01-01

    Ulcerative colitis (UC) is a chronic inflammatory bowel condition characterised by a relapsing and remitting course. Symptom control has been the traditional mainstay of medical treatment. It is well known that histological inflammatory activity persists despite adequate symptom control and absence of endoscopic inflammation. Current evidence suggests that presence of histological inflammation poses a greater risk of disease relapse and subsequent colorectal cancer risk. New endoscopic technologies hold promise for developing endoscopic markers of mucosal inflammation. Achieving endoscopic and histological remission appears be the future aim of medical treatments for UC. This review article aims to evaluate the use of endoscopy as a tool in assessment of mucosal inflammation UC and its correlation with disease outcomes. PMID:27895420

  1. Endoscope-assisted laparoscopic repair of perforated peptic ulcers.

    PubMed

    Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh

    2004-04-01

    Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.

  2. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  3. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  4. Endoscopic medial maxillectomy breaking new frontiers.

    PubMed

    Mohanty, Sanjeev; Gopinath, M

    2013-07-01

    Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management of benign sino-nasal tumours. We present our experience of endoscopic medial maxillectomy in the management of sinonasal pathologies.

  5. Analysis of the color rendition of flexible endoscopes

    NASA Astrophysics Data System (ADS)

    Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard

    2003-03-01

    Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.

  6. Endoscopic Gallbladder Drainage for Acute Cholecystitis

    PubMed Central

    Widmer, Jessica; Alvarez, Paloma; Sharaiha, Reem Z.; Gossain, Sonia; Kedia, Prashant; Sarkaria, Savreet; Sethi, Amrita; Turner, Brian G.; Millman, Jennifer; Lieberman, Michael; Nandakumar, Govind; Umrania, Hiren; Gaidhane, Monica

    2015-01-01

    Background/Aims Surgery is the mainstay of treatment for cholecystitis. However, gallbladder stenting (GBS) has shown promise in debilitated or high-risk patients. Endoscopic transpapillary GBS and endoscopic ultrasound-guided GBS (EUS-GBS) have been proposed as safe and effective modalities for gallbladder drainage. Methods Data from patients with cholecystitis were prospectively collected from August 2004 to May 2013 from two United States academic university hospitals and analyzed retrospectively. The following treatment algorithm was adopted. Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy and cystic duct stenting was initially attempted. If deemed feasible by the endoscopist, EUS-GBS was then pursued. Results During the study period, 139 patients underwent endoscopic gallbladder drainage. Among these, drainage was performed in 94 and 45 cases for benign and malignant indications, respectively. Successful endoscopic gallbladder drainage was defined as decompression of the gallbladder without incidence of cholecystitis, and was achieved with ERCP and cystic duct stenting in 117 of 128 cases (91%). Successful endoscopic gallbladder drainage was also achieved with EUS-guided gallbladder drainage using transmural stent placement in 11 of 11 cases (100%). Complications occurred in 11 cases (8%). Conclusions Endoscopic gallbladder drainage techniques are safe and efficacious methods for gallbladder decompression in non-surgical patients with comorbidities. PMID:26473125

  7. Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery

    PubMed Central

    Friedel, David; Modayil, Rani; Stavropoulos, Stavros N

    2014-01-01

    Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473

  8. Salvage topical therapy for upper tract urothelial carcinoma.

    PubMed

    Balasubramanian, Adithya; Metcalfe, Michael J; Wagenheim, Gavin; Xiao, Lianchun; Papadopoulos, John; Navai, Neema; Davis, John W; Karam, Jose A; Kamat, Ashish M; Wood, Christopher G; Dinney, Colin P; Matin, Surena F

    2018-05-26

    Topical therapy (TT) for upper tract urothelial carcinoma (UTUC) has been explored as a kidney sparing approach to treat carcinoma in situ (CIS) and as adjuvant for endoscopically treated Ta/T1 tumors. In bladder cancer, data support use of salvage TT for repeat induction. We investigate the outcomes of salvage TT for UTUC in patients ineligible for or refusing nephroureterectomy. A single-center retrospective review on patients receiving salvage TT via percutaneous nephrostomy tube or cystoscopically placed ureteral catheters was performed. Primary outcome was response to therapy based on International Bladder Cancer Group criteria. 51 patients with 58 renal units (RUs) received TT. Of these, 17 patients with 18 RUs received the second-line TT, with a median follow-up of 36.5 months (IQR 24.5-67 months). 44% (8/18) received salvage TT for refractory disease and 56% (10/18) as reinduction. 5 RUs with CIS were unresponsive to initial TT and went on to receive salvage TT, of which 20% (1/5) responded. 13 RUs recurred or relapsed following initial TT and received salvage TT for papillary tumors, with 62% (8/13) responding. Our data provide preliminary clinical rationale for the second-line TT for refractory and recurrent, endoscopically managed papillary UTUC in patients ineligible for or refusing nephroureterectomy. However, refractory upper tract CIS appears to have poor response to salvage TT.

  9. Single incision endoscopic surgery for gynaecomastia.

    PubMed

    Jarrar, G; Peel, A; Fahmy, R; Deol, H; Salih, V; Mostafa, A

    2011-09-01

    Surgical excision has been an effective treatment for gynaecomastia. Recently, there has been a shift from the open approach to minimally invasive techniques. In this report we describe our technique which includes endoscopic excision and/or liposuction of gynaecomastia via a single lateral chest wall incision. Between May 2007 and April 2010, a total of 12 gynaecomastia patients were treated with liposuction and/or endoscopic excision. Patients were divided into 3 groups: group I; liposuction only, group II; endoscopic excision plus liposuction and group III; endoscopic excision only. One 15 mm incision was made laterally at the anterior axillary line. A vacuum assisted liposuction removing the fatty tissue was performed. Then endoscopic excision of the remaining fibroglandular tissue was done under vision through the same incision. The parynchyma was then dissected into small pieces and pulled out. Group I had liposuction only (n = 4), group II had liposuction combined with endoscopic excision (n = 7) (58%) while group III had endoscopic excision only (n = 1). The mean operative time for liposuction and endoscopic excision was 58 min for each side. Mean hospital stay was 1.4 days. Postoperative complications included infection with abscess formation and one patient had seroma. Mean follow-up was 56 weeks. Eleven out of twelve patients (92%) were satisfied with their results. Long-term follow-up showed that results were stable over time, and no revisions were necessary. Endoscopic excision of gynaecomastia through a single lateral chest wall incision is a minimally invasive effective and safe technique for the management of gynaecomastia, with excellent aesthetic results and an acceptable complication rate. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Current Status of Peroral Endoscopic Myotomy

    PubMed Central

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656

  11. Current Status of Peroral Endoscopic Myotomy.

    PubMed

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  12. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    PubMed Central

    van den Broek, Frank JC; de Graaf, Eelco JR; Dijkgraaf, Marcel GW; Reitsma, Johannes B; Haringsma, Jelle; Timmer, Robin; Weusten, Bas LAM; Gerhards, Michael F; Consten, Esther CJ; Schwartz, Matthijs P; Boom, Maarten J; Derksen, Erik J; Bijnen, A Bart; Davids, Paul HP; Hoff, Christiaan; van Dullemen, Hendrik M; Heine, G Dimitri N; van der Linde, Klaas; Jansen, Jeroen M; Mallant-Hent, Rosalie CH; Breumelhof, Ronald; Geldof, Han; Hardwick, James CH; Doornebosch, Pascal G; Depla, Annekatrien CTM; Ernst, Miranda F; van Munster, Ivo P; de Hingh, Ignace HJT; Schoon, Erik J; Bemelman, Willem A; Fockens, Paul; Dekker, Evelien

    2009-01-01

    Background Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require expensive equipment, general anesthesia and hospital admission. Furthermore, EMR appears to be associated with fewer complications. The aim of this study is to compare the cost-effectiveness and cost-utility of TEM and EMR for the resection of large rectal adenomas. Methods/design Multicenter randomized trial among 15 hospitals in the Netherlands. Patients with a rectal adenoma ≥ 3 cm, located between 1–15 cm ab ano, will be randomized to a TEM- or EMR-treatment strategy. For TEM, patients will be treated under general anesthesia, adenomas will be dissected en-bloc by a full-thickness excision, and patients will be admitted to the hospital. For EMR, no or conscious sedation is used, lesions will be resected through the submucosal plane in a piecemeal fashion, and patients will be discharged from the hospital. Residual adenoma that is visible during the first surveillance endoscopy at 3 months will be removed endoscopically in both treatment strategies and is considered as part of the primary treatment. Primary outcome measure is the proportion of patients with recurrence after 3 months. Secondary outcome measures are: 2) number of days not spent in hospital from initial treatment until 2 years afterwards; 3) major and minor morbidity; 4) disease specific and general quality of life; 5) anorectal function; 6) health care utilization and costs. A cost-effectiveness and cost-utility analysis of EMR against TEM for large rectal adenomas will be performed from a societal perspective with respectively the costs per recurrence free patient and the cost per quality adjusted life year as outcome measures. Based on comparable recurrence rates for TEM and EMR of 3.3% and

  13. [Percutaneous endoscopic gastrostomy].

    PubMed

    Kuz'min-Krutetskiĭ, M I; Demko, A E; Safoev, A I; Akkalaeva, A É; Karimova, L I

    2014-01-01

    The percutaneous endoscopic gastrostomy takes an important place in operative endoscopy of the digestive system. At the same time it is the method of choice in patients who need a long-term administration of enteral feeding. Given article reflects the main indications, contraindications and complications of the percutaneous endoscopic gastrostomy and presents the basic stages of the method. The authors hope, that the data would be useful for both entry-lever surgeon-endoscopists and specialists who used the method.

  14. Retrograde gastroesophageal intussusception after peroral endoscopic myotomy in a patient with achalasia cardia: A case report.

    PubMed

    Khan, Samiullah; Su, Shuai; Jiang, Kui; Wang, Bang-Mao

    2018-01-01

    Retrograde gastroesophageal intussusception (RGEI) is a relatively rare gastrointestinal (GI) disorder in which a portion of the stomach wall invaginates into the esophagus. More recently, peroral endoscopic myotomy (POEM) has emerged as an endoscopic alternative to surgical myotomy for achalasia, and, to the best of our knowledge, our case is the first RGEI after POEM to be reported. A 22-year-old male was presented with a history of vomiting, intractable retching and hematemesis for 3 days. He had a history of achalasia and underwent POEM 3 years ago caused by symptoms of severe dysphagia to solid and liquid. Initially, the patient was diagnosed with a blood-filled esophagus, and the mid esophagus was occluded with a ball-like mass, however, the final diagnosis of RGEI was made by thoracotomy. A therapeutic strategy of conservative treatment and left transthoracic surgery were applied. The surgery and post operative course were uneventful, and he remained asymptomatic 1 year after operation. POEM is a reliable and minimally invasive endoscopic method for esophageal achalasia. Early recognition and severity of RGEI are essential to decrease the unwanted complications. Upper GI series, esophagogastroduodenoscopy and computed tomography scan are helpful for diagnostic purposes of RGEI. Conservative treatment, endoscopic intervention, and surgery are the mainstay of treatments for RGEI. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  15. Zn concentration in esophageal tissue in patients with and without upper gastrointestinal disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, R.K.H.; Kadakia, S.C.; Maydonovitch, C.

    1986-03-05

    Measurements of tissue Zn in humans with upper gastrointestinal disease could provide information about underlying pathophysiology but these data have never been obtained. With recent endoscopic methods they obtained 2-6 mg pinch mucosal biopsies of epithelium and lamina propria from proximal (P), middle (M) and distal (D) areas of esophagus under direct vision through a flexible 1 cm endoscope in 35 subjects without gastrointestinal disease (N) and in 35 patients with the following endoscopically proven gastrointestinal pathology: 12 with esophagitis (E), 14 with duodenal ulcer disease (DU) and 9 with gastritis (G). Samples were dried, weighed, digested with HNO/sub 3/,more » dried, resuspended in 3% HNO/sub 3/ and Zn estimated by flame atomic absorption spectrophotometry. Esophageal Zn in N decreased progressively as biopsies extended from P to D (P, 108 +/- 29 ..mu..g/g dry weight, Mean +/- SEM; M, 158 +/- 23; D, 134 +/- 16) but this pattern was generally reversed in patients, with D consistently demonstrating Zn elevated 50-120% above normal. The greatest increase was in G in whom Zn in D was more than twice normal (DU, 290 +/- 76, p < 0.01). These are the first Zn levels obtained from esophagus in living human subjects and indicate (1) a specific pattern of Zn distribution in normal esophagus and (2) a significantly altered pattern in D in several diseases of the upper gastrointestinal tract.« less

  16. Finding of biliary fascioliasis by endoscopic ultrasonography in a patient with eosinophilic liver abscess.

    PubMed

    Behzad, Catherine; Lahmi, Farhad; Iranshahi, Majid; Mohammad Alizadeh, Amir Houshang

    2014-09-01

    Fascioliasis is an endemic zoonotic disease in Iran. It occurs mainly in sheep-rearing areas of temperate climates, but sporadic cases have been reported from many other parts of the world. The usual definitive host is the sheep. Humans are accidental hosts in the life cycle of Fasciola. Typical symptoms may be associated with fascioliasis, but in some cases diagnosis and treatment may be preceded by a long period of abdominal pain and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 6 months, with imaging suggesting liver abscess and normal biliary ducts. The patient had no eosinophilia with negative stool examinations, so she was initially treated with antibiotics for liver abscess. Her clinical condition as well as follow-up imagings showed appropriate response after antibiotic therapy. Finally, endoscopic ultrasonography revealed Fasciola hepatica, which was then extracted with endoscopic retrograde cholangiopancreatography.

  17. Endoscopic management of hilar biliary strictures

    PubMed Central

    Singh, Rajiv Ranjan; Singh, Virendra

    2015-01-01

    Hilar biliary strictures are caused by various benign and malignant conditions. It is difficult to differentiate benign and malignant strictures. Postcholecystectomy benign biliary strictures are frequently encountered. Endoscopic management of these strictures is challenging. An endoscopic method has been advocated that involves placement of increasing number of stents at regular intervals to resolve the stricture. Malignant hilar strictures are mostly unresectable at the time of diagnosis and only palliation is possible.Endoscopic palliation is preferred over surgery or radiological intervention. Magnetic resonance cholangiopancreaticography is quite important in the management of these strictures. Metal stents are superior to plastic stents. The opinion is divided over the issue of unilateral or bilateral stenting.Minimal contrast or no contrast technique has been advocated during endoscopic retrograde cholangiopancreatography of these patients. The role of intraluminal brachytherapy, intraductal ablation devices, photodynamic therapy, and endoscopic ultrasound still remains to be defined. PMID:26191345

  18. Endoscopes with latest technology and concept.

    PubMed

    Gotoh

    2003-09-01

    Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.

  19. Endoscopic balloon dilatation as an effective treatment for lower and upper benign gastrointestinal system anastomotic stenosis.

    PubMed

    Akarsu, Cevher; Unsal, Mustafa Gokhan; Dural, Ahmet Cem; Kones, Osman; Kocatas, Ali; Karabulut, Mehmet; Kankaya, Burak; Ates, Mustafa; Alis, Halil

    2015-04-01

    Endoscopic balloon dilatation (EBD) is currently accepted as an effective, safe, and first-line treatment of postoperative benign gastrointestinal anastomosis stenosis (BGAS); however, a limited number of publications on the subject exist in the literature. The aim of the study was to retrospectively evaluate the efficiency of endoscopic dilatation in patients with postoperative intestinal anastomotic stenoses at a single surgical center. Patients with postoperative BGAS treated by EBD at our institution from February 2008 to 2012 were included. The dilatations were all performed using through-the-scope balloons. The balloon was introduced into the stricture using a guidewire under radiologic guidance. Each dilatation session consisted of 2 to 3 two-minute multistep inflations of the balloon until adequate dilatation was achieved. Of the 48 patients included in the study, 44 patients (91.7%) fully recovered and 4 (8.3%) did not respond to treatment. The mean follow-up period was 24 months (range, 3 to 57 mo). Four patients who did not respond to the procedure were treated surgically. Two patients (4.1%) with intestinal perforation during EBD were treated conservatively with a stent. EBD has a low rate of complications and a high success rate, is well tolerated, and avoids further surgical procedures for BGAS. Therefore, EBD should be the first choice of treatment for postoperative anastomotic stenoses.

  20. Endoscopic pancreatic necrosectomy.

    PubMed

    Fogel, Evan L

    2011-07-01

    Traditionally, patients with symptomatic sterile pancreatic necrosis or infected necrosis have been managed by open surgical debridement and removal of necrotic tissue. Within the last decade, however, reports of endoscopic pancreatic necrosectomy, an alternative minimally invasive approach, have demonstrated high success rates and low mortality rates. This report describes the indications, technique, and study outcome data of the procedure. While our experience with this technique has recently increased, better selection criteria are needed to identify patients who are most suitable for endoscopic therapy.

  1. Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.

    PubMed

    Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M

    2018-06-04

    Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.

  2. Endoscopic papillectomy: indications, techniques, and results.

    PubMed

    De Palma, Giovanni D

    2014-02-14

    Endoscopic papillectomy (EP) is currently accepted as a viable alternative therapy to surgery in sporadic ampullary adenoma and has been reported to have high success and low recurrence rates. At present, the indications for EP are not yet fully established. The accepted criteria for EP include size (up to 5 cm), no evidence of intraductal growth, and no evidence of malignancy on endoscopic findings (ulceration, friability, and spontaneous bleeding). Endoscopic ultrasound (EUS) is the imaging modality of choice for local T staging in ampullary neoplasms. Data reported in the literature have revealed that linear EUS is superior to helical computed tomography in the preoperative assessment of tumor size, detection of regional nodal metastases and detection of major vascular invasion. Endoscopic ampullectomy is performed using a standard duodenoscope in a similar manner to snare polypectomy of a mucosal lesion. There is no standardization of the equipment or technique and broad EP methods are described. Endoscopic ampullectomy is considered a ''high-risk'' procedure due to complications. Complications of endoscopic papillectomy can be classified as early (pancreatitis, bleeding, perforation, and cholangitis) and late (papillary stenosis) complications. The appropriate use of stenting after ampullectomy may prevent post-procedural pancreatitis and papillary stenosis. Tumor recurrence of benign lesions occurs in up to 20% of patients and depends on tumor size, final histology, presence of intraductal tumor, coexisting familial adenomatous polyposis (FAP), and the expertise of the endoscopist. Recurrent lesions are usually benign and most can be retreated endoscopically.

  3. Laser scanning endoscope for diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Ouimette, Donald R.; Nudelman, Sol; Spackman, Thomas; Zaccheo, Scott

    1990-07-01

    A new type of endoscope is being developed which utilizes an optical raster scanning system for imaging through an endoscope. The optical raster scanner utilizes a high speed, multifaceted, rotating polygon mirror system for horizontal deflection, and a slower speed galvanometer driven mirror as the vertical deflection system. When used in combination, the optical raster scanner traces out a raster similar to an electron beam raster used in television systems. This flying spot of light can then be detected by various types of photosensitive detectors to generate a video image of the surface or scene being illuminated by the scanning beam. The optical raster scanner has been coupled to an endoscope. The raster is projected down the endoscope, thereby illuminating the object to be imaged at the distal end of the endoscope. Elemental photodetectors are placed at the distal or proximal end of the endoscope to detect the reflected illumination from the flying spot of light. This time sequenced signal is captured by an image processor for display and processing. This technique offers the possibility for very small diameter endoscopes since illumination channel requirements are eliminated. Using various lasers, very specific spectral selectivity can be achieved to optimum contrast of specific lesions of interest. Using several laser lines, or a white light source, with detectors of specific spectral response, multiple spectrally selected images can be acquired simultaneously. The potential for co-linear therapy delivery while imaging is also possible.

  4. Gynaecological endoscopic surgical education and assessment. A diploma programme in gynaecological endoscopic surgery.

    PubMed

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills, are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA) recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high-stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy, (b) the Minimally Invasive Gynaecological Surgeon (MIGS) and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence, and it counteracts the problem of the traditional surgical apprentice-tutor model. It is seen as a major step toward standardisation of endoscopic surgical training in general.

  5. Gynaecological Endoscopic Surgical Education and Assessment. A diploma programme in gynaecological endoscopic surgery.

    PubMed

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    2016-04-01

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA), recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy; (b) the Minimally Invasive Gynaecological Surgeon (MIGS); and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence and it counteracts the problem of the traditional surgical apprentice tutor model. It is seen as a major step toward standardization of endoscopic surgical training in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Telemetric real-time sensor for the detection of acute upper gastrointestinal bleeding.

    PubMed

    Schostek, Sebastian; Zimmermann, Melanie; Keller, Jan; Fode, Mario; Melbert, Michael; Schurr, Marc O; Gottwald, Thomas; Prosst, Ruediger L

    2016-04-15

    Acute upper gastrointestinal bleedings from ulcers or esophago-gastric varices are life threatening medical conditions which require immediate endoscopic therapy. Despite successful endoscopic hemostasis, there is a significant risk of rebleeding often requiring close surveillance of these patients in the intensive care unit (ICU). Any time delay to recognize bleeding may lead to a high blood loss and increases the risk of death. A novel telemetric real-time bleeding sensor can help indicate blood in the stomach: the sensor is swallowed to detect active bleeding or is anchored endoscopically on the gastrointestinal wall close to the potential bleeding source. By telemetric communication with an extra-corporeal receiver, information about the bleeding status is displayed. In this study the novel sensor, which measures characteristic optical properties of blood, has been evaluated in an ex-vivo setting to assess its clinical applicability and usability. Human venous blood of different concentrations, various fluids, and liquid food were tested. The LED-based sensor was able to reliably distinguish between concentrated blood and other liquids, especially red-colored fluids. In addition, the spectrometric quality of the small sensor (size: 6.5mm in diameter, 25.5mm in length) was comparable to a much larger and technically more complex laboratory spectrophotometer. The experimental data confirm the capability of a miniaturized sensor to identify concentrated blood, which could help in the very near future the detection of upper gastrointestinal bleeding and to survey high-risk patients for rebleeding. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  8. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial

    PubMed Central

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-01-01

    Introduction The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. Methods and analysis We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. Ethics and dissemination This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016–0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. Trial registration number The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. PMID:28801436

  9. Design of the computerized 3D endoscopic imaging system for delicate endoscopic surgery.

    PubMed

    Song, Chul-Gyu; Kang, Jin U

    2011-02-01

    This paper describes a 3D endoscopic video system designed to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. In a comparison of the polarized and conventional electric shutter-type stereo imaging systems, the former was found to be superior in terms of both accuracy and speed for suturing and for the loop pass test. Among the groups performing loop passing and suturing, there was no significant difference in the task performance between the 2D and 3D modes, however, suturing was performed 15% (p < 0.05) faster in 3D mode by both groups. The results of our experiments show that the proposed 3D endoscopic system has a sufficiently wide viewing angle and zone for multi-viewing.

  10. Towards automated visual flexible endoscope navigation.

    PubMed

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  11. Initial design of a novel suction enteroscope for endoscopic locomotion in the small bowel (with video).

    PubMed

    Wagh, Mihir S; Montane, Roberto

    2012-02-01

    The upper GI tract and the colon are readily accessible endoscopically, but the small intestine is relatively difficult to evaluate. To demonstrate the feasibility of using suction as a means of locomotion and to assess the initial design of a suction enteroscope. Feasibility study. Animal laboratory. Various prototype suction devices designed in our laboratory were tested in swine small intestine in a force test station. For in vivo experiments in live anesthetized animals, two suction devices (1 fixed tip and 1 movable tip) were attached to the outside of the endoscope. By creating suction in the fixed tip, the endoscope was anchored while the movable tip was advanced. Suction was then applied to the extended tip to attach it to the distal bowel. Suction on the fixed tip was then released and the movable tip with suction pulled back, resulting in advancement of the endoscope. These steps were sequentially repeated. Intestinal segments were sent for pathologic assessment after testing. Force generated ranged from 0.278 to 4.74 N with 64.3 to 88 kPa vacuum pressure. A linear relationship was seen between the pull force and vacuum pressures and tip surface area. During in vivo experiments, the endoscope was advanced in 25-cm segmental increments with sequential suction-and-release maneuvers. No significant bowel trauma was seen on pathology and necropsy. The enteroscopy system requires further refinement. A novel suction enteroscope was designed and tested. Suction tip characteristics played a critical role impacting the functionality of this enteroscopy system. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Endoscopic therapeutic esophageal interventions.

    PubMed

    Schembre, D B; Kozarek, R A

    2000-07-01

    At the close of the 20th century, therapeutic endoscopy in the esophagus has expanded to encompass a broad array of interventions. As the number of procedures grows, emphasis in the medical literature has begun to shift to analyses of which procedures should be performed. Many studies published in 1999 on topics ranging from endoscopic treatment of benign and malignant strictures, to variceal bleeding, to Barrett esophagus have focused on which of several methods provides the best long-term response with the fewest interventions. This is a review of the major published studies of endoscopic interventions in the esophagus as well as selected abstracts. The conclusions of these studies and reports of new endoscopic therapies draw a clear map of where nonoperative esophageal therapeutics are headed in the next several years.

  13. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial.

    PubMed

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-08-11

    The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. [1-st Young Scientist's Competitions. Endoscopic diagnosis of esophageal pathology in HIV-infected patients with active tuberculosis].

    PubMed

    Trefil'eva, E I

    2009-01-01

    The main object of this work was to determine the role and place of esophagogastroduodenoscopy (EGDS) in the diagnostic diseases upper portion of the gastrointestinal tract. We analysed endoscopic pictures of patients, which have HIV and active form of tuberculosis (T. B.). 141 patients with HIV/T. B., who are on the treatment in Tubercular hospital No 11 of Moscow, were examined during 2008 year. About 86% of patients (121 of 141) had a positive endoscopic picture of gastroesophageal reflux disease (GERB). About 69.5% of patients had a mycotic lesion of esophagus: 52 patients (17.8%) had a mycotic lesion of esophagus, which was visually discovered by EGDS; mycotic lesion of esophagus was confirmed by method of polymerase chain reaction (PCR (at 46 patients (51.7%)). The smear for identification micobacteria of tuberculosis was taken from 52 patients (from group 89 patients) with negative endoscopic picture of a mycotic lesion by method PCR additionally. The results have shown, that 23 patients have a positive reaction (43.4%). A diagnostic bronchoscopy was made to examed group. 20 patients from 141 with HIV (14.9%) had a positive result PCR of mycotic lesion. It shows that a defeat of candidosis take place not only in the gastrointestinal tract, but also in the bronchial tree. EGDS+ PCR+ histology is the basis method of the diagnostic diseases upper portion of the gastrointestinal tract. This research established that almost 70% of patients with HIV/T. B. have mycotic lesion of esophagus and 86%--defeat of GERB. That's why, we recommend to include proton- pump inhibitors and antimycotic preparations in the scheme of patient's treatment.

  15. [Tracheotomy-endoscop for dilatational percutaneous tracheotomy (TED)].

    PubMed

    Klemm, Eckart

    2006-09-01

    While surgical tracheotomies are currently performed using state-of-the-art operative techniques, percutaneous dilatational tracheostomy (PDT) is in a rapidly evolving state with regard to its technology and the number of techniques available. This has resulted in a range of new complications that are difficult to quantify on a scientific basis, given the fact that more than half of the patients who are tracheotomized in intensive care units die from their underlying disease. The new Tracheotomy Endoscope (TED) is designed to help prevent serious complications in dilatational tracheotomies and facilitate their management. The endoscope has been specifically adapted to meet the require-ments of percutaneous dilatational tracheotomies. It is fully compatible with all current techniques of PDT. The method is easy to learn. The percutaneous dilatational tracheotomy with the Tracheotomy Endoscope is a seven-step procedure: Advantages of the Tracheotomy Endoscope: Injuries to the posterior tracheal wall ar impossible (tracheoesophageal fistulas, pneumothorax). Minor bleeding sites on the tracheal mucosa can be controlled with a specially curved suction-coagulation tube introudeced through the Tracheotomy Endoscope. In cases with heavy bleeding and a risk of aspiration, the rigid indwelling Tracheotomy Endoscope provides a secure route for reintubating the patient with a cuffed endotracheal tube. It also allows for rapid conversion to an open surgical procedure if necessary. All the parts are easy to clean and are autoclavable. This type of endoscopically guided PDT creates an optimal link between the specialties of intensive care medicine and otorhinolaryngology. The Tracheotomy Endoscope (TED) increases the standard of safety in PDT.

  16. [Upper gastrointestinal bleeding: usefulness of prognostic scores].

    PubMed

    Badel, S; Dorta, G; Carron, P-N

    2011-08-24

    Upper gastrointestinal bleeding is a potentially serious event, usually requiring urgent endoscopic treatment. Better stratification of the risk of complication or death could optimize management and improve patient outcomes, while ensuring adequate resource allocation. Several prognostic scores have been developed, in order to identify high risk patients, who require immediate treatment, and patients at low risk for whom endoscopy may be delayed. An ideal prognostic score should be accurate, simple, reproducible, and prospectively validated in different populations. Published scores meet these requirements only partially, and thus can only be used as part of an integrative diagnostic and therapeutic process.

  17. Utility of the Anterior Oblique-Viewing Endoscope and the Double-Balloon Enteroscope for Endoscopic Retrograde Cholangiopancreatography in Patients with Billroth II Gastrectomy

    PubMed Central

    Sen-yo, Manabu; Kaino, Seiji; Suenaga, Shigeyuki; Uekitani, Toshiyuki; Yoshida, Kanako; Harano, Megumi; Sakaida, Isao

    2012-01-01

    Background/Purpose. The difficulties of endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy have been reported. We evaluated the usefulness of an anterior oblique-viewing endoscope and a double-balloon enteroscope for endoscopic retrograde cholangiopancreatography in such patients. Methods. From January 2003 to December 2011, 65 patients with Billroth II gastrectomy were enrolled in this study. An anterior oblique-viewing endoscope was used for all patients. From February 2007, a double-balloon enteroscope was used for the failed cases. The success rate of procedures was compared with those in 20 patients with Billroth II gastrectomy using forward-viewing endoscope or side-viewing endoscope from March 1996 to July 2002 as historical controls. Results. In all patients in whom the papilla was reached (60/65), selective cannulation was achieved. The success rate of selective cannulation and accomplishment of planned procedures in the anterior oblique-viewing endoscope group were both significantly higher than that in the control group (100% versus 70.1%, 100 versus 58.8%, resp.). A double-balloon enteroscope was used in 2 patients, and the papilla could be reached and the planned procedures completed. Conclusions. An anterior oblique-viewing endoscope and double-balloon enteroscope appear to be useful in performing endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy. PMID:23056039

  18. Endoscopic Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Zhou, Chao; Fujimoto, James G.; Tsai, Tsung-Han; Mashimo, Hiroshi

    New gastrointestinal (GI) cancers are expected to affect more than 290,200 new patients and will cause more than 144,570 deaths in the United States in 2013 [1]. When detected and treated early, the 5-year survival rate for colorectal cancer increases by a factor of 1.4 [1]. For esophageal cancer, the rate increases by a factor of 2 [1]. The majority of GI cancers begin as small lesions that are difficult to identify with conventional endoscopy. With resolutions approaching that of histopathology, optical coherence tomography (OCT) is well suited for detecting the changes in tissue microstructure associated with early GI cancers. Since the lesions are not endoscopically apparent, however, it is necessary to survey a relatively large area of the GI tract. Tissue motion is another limiting factor in the GI tract; therefore, in vivo imaging must be performed at extremely high speeds. OCT imaging can be performed using fiber optics and miniaturized lens systems, enabling endoscopic OCT inside the human body in conjunction with conventional video endoscopy. An OCT probe can be inserted through the working channel of a standard endoscope, thus enabling depth-resolved imaging of tissue microstructure in the GI tract with micron-scale resolution simultaneously with the endoscopic view (Fig. 68.1).

  19. Successes rate of endoscopic dacryocystorhinostomy at KMC.

    PubMed

    Shrestha, S; Kafle, P K; Pokhrel, S; Maharjan, M; Toran, K C

    2010-01-01

    Nasolacrimal duct obstruction is a common problem which can be corrected by dacryocystorhinostomy (DCR). The gold standard treatment for this is DCR operation through an external approach. Development of endoscopic sinus surgery and endoscopic DCR performed through intranasal route is a major recent development in this field. The aim of this study is to find out the success rate of endoscopic dacryocystorhinostomy without silicon stent intubation within the period of six month following surgery. A prospective study was done on 26 patients with obstruction of the nasolacrimal duct referred from eye out-patient department to ENT OPD during one year period from 2008 to 2009. All the cases had undergone endoscopic DCR operation which was regularly followed up for a period of six months. Postoperative patency of ostium was checked by sac syringing and endoscopic visualisation of ostium in the nasal cavity. The success of surgery was categorised as: complete cure, partial cure and no improvement depending upon symptomatic relief and clinical examination such as sac syringing and endoscopic examination following surgery. In six months' follow-up, 22 (84.5%) out of 26 patients had achieved the complete cure and 4 patients (15.5%) continued to have persistent epiphora. Endoscopic DCR is a beneficial procedure for nasolacrimal duct obstruction with no external scar on face and less bleeding. The success rate is as good as external DCR.

  20. Diagnosis and endoscopic treatment of esophago-bronchial fistula due to gastric heterotopy.

    PubMed

    Katsanos, Konstantinos H; Christodoulou, Dimitrios K; Kamina, Sevasti; Maria, Kosmidou; Lambri, Evangelia; Theodorou, Stavroula; Tsampoulas, Konstantinos; Vasiliki, Mitsi; Tsianos, Epameinondas V

    2010-04-16

    Heterotopic gastric mucosa patches are congenital gastrointestinal abnormalities and have been reported to occur anywhere along the gastrointestinal tract from mouth to anus. Complications of heterotopic gastric mucosa include dysphagia, upper gastrointestinal bleeding, upper esophageal ring stricture, adenocarcinoma and fistula formation. In this case report we describe the diagnosis and treatment of the first case of esophago-bronchial fistula due to heterotopic gastric mucosa in mid esophagus. A 40-year old former professional soccer player was referred to our department for treatment of an esophago-bronchial fistula. Microscopic examination of the biopsies taken from the esophageal fistula revealed the presence of gastric heterotopic mucosa. We decided to do a non-surgical therapeutic endoscopic procedure. A sclerotherapy catheter was inserted through which 1 mL of ready to use synthetic surgical glue was applied in the fistula and it closed the fistula opening with excellent results.

  1. Emergency treatment of esophageal varix incarceration in the endoscope and ligation device during endoscopic variceal rubber band ligation

    PubMed Central

    Zhao, Hong; Cheng, Jilin; Xu, Yahong; Lu, Cuili; Huang, Shaoping; Fan, Zhenyu; Shi, Yuxin

    2014-01-01

    Sclerotherapy and endoscopic esophageal variceal ligation (EVL) are commonly used to treat and prevent variceal bleeding. As of today, there has been no report on an unexpected incarceration of a varix hooked on with the bands from the endoscopic EVL device. We recently experienced this emergency while using the 7-band ring endoscopic EVL device (Boston Scientific Corp., Boston, MA) for prophylaxis of variceal bleeding. In this case, the varix body itself was accidently incarcerated in the crevice of the esophageal endoscope after highly negative pressure of absorption was applied on the endoscope. In this situation, using force to take out the gastroscope was not an option as it would tear the vein and cause massive hemorrhage. We were managed to ligate the varix with rubber bands while releasing the incarceration. We observed that ligation of the varix at the same position using all seven ligation bands resulted in disappearance of the targeted varix. The surrounding esophageal mucosa became smooth after the treatment. PMID:25550983

  2. [Endoscopic Approach to the Quadrilateral Plate (EAQUAL): a New Endoscopic Approach for Plate Osteosynthesis of the Pelvic Ring and Acetabulum - a Cadaver Study].

    PubMed

    Trulson, Alexander; Küper, Markus Alexander; Trulson, Inga Maria; Minarski, Christian; Grünwald, Leonard; Hirt, Bernhard; Stöckle, Ulrich; Stuby, Fabian

    2018-06-14

    Dislocated pelvic fractures which require surgical repair are usually operated on via open surgery. Approach-related morbidity is reported with a frequency of up to 30%. The aim of this anatomical study was to prove the feasibility of endoscopic visualisation of the relevant anatomical structures in pelvic surgery and to perform completely endoscopic plate osteosynthesis of the acetabulum with available standard laparoscopic instruments. In four human cadavers, we established an endoscopic preparation of the complete pelvic ring, from the symphysis to the iliosacral joint, including the quadrilateral plate and the sciatic nerve, and performed endoscopic plate osteosynthesis along the iliopectineal line. The endoscopic preparation of the complete pelvic ring and the quadrilateral plate was demonstrated step-by-step, followed by completely endoscopic plate osteosynthesis along the pelvic brim. Endoscopic, radiographic, and schematic pictures are used to illustrate the technique. The completely endoscopic preparation of the pelvic brim and the quadrilateral plate is feasible with available standard laparoscopic instruments. Moreover, plate osteosynthesis could be performed endoscopically. Further research on reduction techniques is necessary when planning to implement this technique into a clinical scenario. Georg Thieme Verlag KG Stuttgart · New York.

  3. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature.

    PubMed

    Snyder, Rita; Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-06-09

    The pineal gland has a deep central location, making it a surgeon's no man's land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches.

  4. Efficacy of deep biopsy for subepithelial lesions in the upper gastrointestinal tract.

    PubMed

    Vaicekauskas, Rolandas; Stanaitis, Juozas; Valantinas, Jonas

    2016-01-01

    Accurate diagnosis of subepithelial lesions (SELs) in the gastrointestinal tract depends on a variety of methods: endoscopy, endoscopic ultrasound and different types of biopsy. Making an error-free diagnosis is vital for the subsequent application of an appropriate treatment. To evaluate the efficacy of deep biopsy via the endoscopic submucosal dissection (ESD) technique for SELs in the upper gastrointestinal tract. It was a case series study. Deep biopsy via the ESD technique was completed in 38 patients between November 2012 and October 2014. Thirty-eight SELs in the upper gastrointestinal tract of varying size (very small ≤ 1 cm, small 1-2 cm and large ≥ 2 cm) by means of the ESD technique after an incision with an electrosurgical knife of the overlying layers and revealing a small part of the lesion were biopsied under direct endoscopic view. Deep biopsy via the ESD technique was diagnostic in 28 of 38 patients (73.3%; 95% CI: 59.7-89.7%). The diagnostic yield for SELs with a clear endophytic shape increased to 91.3%. An evident endophytic appearance of a subepithelial lesion, the mean number of biopsied samples (6.65 ±1.36) and the total size in length of all samples per case (19.88 ±8.07 mm) were the main criteria influencing the positiveness of deep biopsy in the diagnostic group compared to the nondiagnostic one (p = 0.001; p = 0.025; p = 0.008). Deep biopsy via the ESD technique is an effective and safe method for the diagnosis of SELs especially with a clear endophytic appearance in a large number of biopsied samples.

  5. Endoscopic versus surgical drainage treatment of calcific chronic pancreatitis.

    PubMed

    Jiang, Li; Ning, Deng; Cheng, Qi; Chen, Xiao-Ping

    2018-04-21

    Endoscopic therapy and surgery are both conventional treatments to remove pancreatic duct stones that developed during the natural course of chronic pancreatitis. However, few studies comparing the effect and safety between surgery drainage and endoscopic drainage (plus Extracorporeal Shock Wave Lithotripsy, ESWL).The aim of this study was to compare the benefits between endoscopic and surgical drainage of the pancreatic duct for patients with calcified chronic pancreatitis. A total of 86 patients were classified into endoscopic/ESWL (n = 40) or surgical (n = 46) treatment groups. The medical records of these patients were retrospectively analyzed. Pain recurrence and hospital stays were similar between the endoscopic/ESWL treatment and surgery group. However, endoscopic/ESWL treatment yielded significantly lower medical expense and less complications compared with the surgical treatment. In selective patients, endoscopic/ESWL treatment could achieve comparable efficacy to the surgical treatment. With lower medical expense and less complications, endoscopic/ESWL treatment would be much preferred to be the initial treatment of choice for patients with calcified chronic pancreatitis. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    PubMed

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  7. Evaluation of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope

    NASA Astrophysics Data System (ADS)

    Yoshimoto, Kayo; Watabe, Kenji; Fujinaga, Tetsuji; Iijima, Hideki; Tsujii, Masahiko; Takahashi, Hideya; Takehara, Tetsuo; Yamada, Kenji

    2017-02-01

    Because the view angle of the endoscope is narrow, it is difficult to get the whole image of the digestive tract at once. If there are more than two lesions in the digestive tract, it is hard to understand the 3D positional relationship among the lesions. Virtual endoscopy using CT is a present standard method to get the whole view of the digestive tract. Because the virtual endoscopy is designed to detect the irregularity of the surface, it cannot detect lesions that lack irregularity including early cancer. In this study, we propose a method of endoscopic entire 3D image acquisition of the digestive tract using a stereo endoscope. The method is as follows: 1) capture sequential images of the digestive tract by moving the endoscope, 2) reconstruct 3D surface pattern for each frame by stereo images, 3) estimate the position of the endoscope by image analysis, 4) reconstitute the entire image of the digestive tract by combining the 3D surface pattern. To confirm the validity of this method, we experimented with a straight tube inside of which circles were allocated at equal distance of 20 mm. We captured sequential images and the reconstituted image of the tube revealed that the distance between each circle was 20.2 +/- 0.3 mm (n=7). The results suggest that this method of endoscopic entire 3D image acquisition may help us understand 3D positional relationship among the lesions such as early esophageal cancer that cannot be detected by virtual endoscopy using CT.

  8. Endoscopic and Keyhole Endoscope-assisted Neurosurgical Approaches: A Qualitative Survey on Technical Challenges and Technological Solutions

    PubMed Central

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-01-01

    Introduction The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. Materials and Methods All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent themes analysis. Results Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). Discussion The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Conclusions Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches. PMID:24533591

  9. Robust distortion correction of endoscope

    NASA Astrophysics Data System (ADS)

    Li, Wenjing; Nie, Sixiang; Soto-Thompson, Marcelo; Chen, Chao-I.; A-Rahim, Yousif I.

    2008-03-01

    Endoscopic images suffer from a fundamental spatial distortion due to the wide angle design of the endoscope lens. This barrel-type distortion is an obstacle for subsequent Computer Aided Diagnosis (CAD) algorithms and should be corrected. Various methods and research models for the barrel-type distortion correction have been proposed and studied. For industrial applications, a stable, robust method with high accuracy is required to calibrate the different types of endoscopes in an easy of use way. The correction area shall be large enough to cover all the regions that the physicians need to see. In this paper, we present our endoscope distortion correction procedure which includes data acquisition, distortion center estimation, distortion coefficients calculation, and look-up table (LUT) generation. We investigate different polynomial models used for modeling the distortion and propose a new one which provides correction results with better visual quality. The method has been verified with four types of colonoscopes. The correction procedure is currently being applied on human subject data and the coefficients are being utilized in a subsequent 3D reconstruction project of colon.

  10. Gender identification of shovelnose sturgeon using ultrasonic and endoscopic imagery and the application of the method to the pallid sturgeon

    USGS Publications Warehouse

    Wildhaber, M.L.; Papoulias, D.M.; DeLonay, A.J.; Tillitt, D.E.; Bryan, J.L.; Annis, M.L.; Allert, J.A.

    2005-01-01

    Monthly sampling of shovelnose sturgeon Scaphirhynchus platorynchus, a biological surrogate for the endangered pallid sturgeon Scaphirhynchus albus, was conducted to develop a multiseasonal profile of reproductive stages. Data collected included histological characteristics of gonads from wild caught fish and laboratory and field ultrasonic and endoscopic images. These data were used to compare effectiveness of ultrasonic and endoscopic techniques at identifying gender of adult shovelnose sturgeon at different reproductive stages. The least invasive method (i.e. ultrasound) was least effective while the most invasive (i.e. endoscope through an abdominal incision) was the most effective at identifying shovelnose sturgeon gender. In most cases, success rate for identifying males was greater than females, with success at identifying both genders greater in more advanced reproductive stages. Concomitantly, for most months average reproductive stage was more advanced for males than females. April and May were the months with the most advanced reproductive stage, and were the months when ultrasound was most effective. Methods were also applied in the Upper Missouri River to validate their use on pallid sturgeon Scaphirhynchus albus. Ultrasound was successful at identifying pallid sturgeon gender, however, endoscopic examination through the urogenital duct was only successful at identifying pallid sturgeon gender when the urogenital duct was not opaque. ?? 2005 The Fisheries Society of the British Isles.

  11. Band ligation of gastric antral vascular ectasia is a safe and effective endoscopic treatment.

    PubMed

    Keohane, John; Berro, Wael; Harewood, Gavin C; Murray, Frank E; Patchett, Stephen E

    2013-07-01

    Gastric antral vascular ectasia (GAVE) or 'watermelon stomach' is a rare and often misdiagnosed cause of occult upper gastrointestinal bleeding. Treatment includes conservative measures such as transfusion and endoscopic therapy. A recent report suggests that endoscopic band ligation (EBL) offers an effective alternative treatment. The aim of the present study is to demonstrate our experiences with this novel technique, and to compare argon plasma coagulation (APC) with EBL in terms of safety and efficacy. A retrospective analysis of all endoscopies with a diagnosis of GAVE was carried out between 2004 and 2010. Case records were examined for information pertaining to the number of procedures carried out, mean blood transfusions, mean hemoglobin, and complications. A total of 23 cases of GAVE were treated. The mean age was 73.9 (55-89) years. Female to male ratio was 17:6 and mean follow up was 26 months. Eight patients were treated with EBL with a mean number of treatments of 2.5 (1-5). This resulted in a statistically significant improvement in the endoscopic appearance and a trend towards fewer transfusions. Of the eight patients treated with EBL, six (75%) patients had previously failed APC treatment despite having a mean of 4.7 sessions. Band ligation was not associated with any short- or medium-term complications. The 15 patients who had APC alone had a mean of four (1-11) treatments. Only seven (46.7%) of these patients had any endoscopic improvement with a mean of four sessions. EBL represents a safe and effective treatment for GAVE. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  12. [Endoscopic screening for upper gastrointestinal second primary malignancies in patients with hypopharyngeal squamous cell carcinoma].

    PubMed

    Tian, J J; Xu, W; Lyu, Z H; Ma, J K; Cui, P; Sa, N; Cao, H Y

    2018-04-07

    Objective: To evaluate the usefullness of flexible esophagoscopy and chromoendoscopy with Lugol's solution in the detection of synchronous esophageal neoplasm in patients with hypopharyngeal squamous cell carcinoma (HSCC). Methods: A retrospective review of 96 cases with HSCC that received surgical treatment from March 2016 to March 2017 was accomplished. In these patients, the site of origin were pyriform sinus ( n =75), posterior pharyngeal wall ( n =11) and postcricoid ( n =10). Esophagoscopy was prospectively performed on all patients before treatment for HSCC. All patients underwent conventional white-light endoscopic examination with Lugol chromoendoscopy and narrow band image. Suspicious areas of narrow band image or Lugol-voiding lesions were observed and biopsied. The treatment strategy of primary HSCC was modified according to the presence of synchronous esophageal squamous cell neoplasms by a multidisciplinary approach. Results: Ninety-six patients were enrolled (age ranging from 37-80 years). All patients did not have previous treatment.Histopathological analysis revealed middle to high-grade dysplasia in 5 cases, Tis cancer in 5 cases, cancer in 16 cases and inflammation or normal findings in the others. Four cases were treated with endoscopic submucosal dissection before hypopharygeal surgery, 3 cases with lower esophageal cancers were treated with gastric pull-up combined with free jejunal flap after total circumferential pharyngolaryngectomy (TCPL) and certical esophagectomy, and 14 cases were treated with TCPL, total esophagectomy and gastric pull-up. Conclusions: Esophagoscopy is a feasible and justified procedure in HSCC cases as it enhances the detection of premalignant lesion or second primary cancer. Routine esophagoscopy for detecting synchronous second primary tumor should be recommended for patients with HSCC. The treatment strategy for primary HSCC is modified according to the presence of synchronous second primary tumor.

  13. Endoscopic treatment with fibrin glue of post-intubation tracheal laceration

    PubMed Central

    Cascone, Roberto; Di Natale, Davide; Pierdiluca, Matteo; Mastromarino, Rossella; Natale, Giovanni; De Ruberto, Emanuele; Messina, Gaetana; Vicidomini, Giovanni; Santini, Mario

    2017-01-01

    Post-intubation tracheal laceration (PITL) is a rare and potential life-threatening condition requiring prompt diagnosis and treatment. A conservative treatment is indicated in patients with laceration <2 cm in length while surgery is the treatment of choice for laceration >4 cm. For laceration between 2–4 cm, the best treatment is debate; some authors recommend surgery while others do not definitely exclude endoscopic treatment. Herein, we reported the endoscopic treatment with fibrin glue of PITL. The procedure is performed using a standard video-bronchoscopy in operating room; the patient is in spontaneous breathing and deep sedation. After identification of tracheal laceration, the fibrin glue is injected through a dedicated double lumen catheter into the lesion. After mixing both components of fibrin glue, polymerization of fibrin occurs resulting in an elastic and opaque clot that closes the lesion. The key success of the procedure is based on accurate patient selection. Patients are eligible if (I) they are clinically stable and in spontaneous respiration; (II) with a small and superficial tracheal laceration (≤4 cm in length and without oesophageal injury); (III) localized at level of the upper or middle trachea; and (IV) without clinical and/or radiological signs of mediastinal collection, of emphysema or pneumomediastinum progression, and of infection. PMID:29078663

  14. [Laparoscopic Proximal Gastrectomy as a Surgical Treatment for Upper Third Early Gastric Cancer].

    PubMed

    Park, Do Joong; Park, Young Suk; Ahn, Sang Hoon; Kim, Hyung Ho

    2017-09-25

    Recently, the incidence of upper third gastric cancer has increased, and with it the number of endoscopic submucosal dissection (ESD) procedures performed has been increasing. However, if ESD is not indicated or non-curable, surgical treatment may be necessary. In the case of lower third gastric cancer, it is possible to preserve the upper part of the stomach; however, in the case of upper third gastric cancer, total gastrectomy is still the standard treatment option, regardless of the stage. This is due to the complications associated with upper third gastric cancer, such as gastroesophageal reflux after proximal gastrectomy rather than oncologic problems. Recently, the introduction of the double tract reconstruction method after proximal gastrectomy has become one of the surgical treatment methods for upper third early gastric cancer. However, since there has not been a prospective comparative study evaluating its efficacy, the ongoing multicenter prospective randomized controlled trial (KLASS-05) comparing laparoscopic proximal gastrectomy with double tract reconstruction and laparoscopic total gastrectomy is expected to be important for determining the future of treatment of upper third early gastric cancer.

  15. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature

    PubMed Central

    Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-01-01

    The pineal gland has a deep central location, making it a surgeon’s no man’s land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches. PMID:28690962

  16. Endoscopic Management of an Intramural Sinus Leak After Per- Oral Endoscopic Myotomy

    PubMed Central

    Al Taii, Haider; Confer, Bradley; Gabbard, Scott; Kroh, Matthew; Jang, Sunguk; Rodriguez, John; Parsi, Mansour A.; Vargo, John J.; Ponsky, Jeffrey

    2016-01-01

    Per-oral endoscopic myotomy (POEM) was developed less than a decade ago for the treatment of achalasia. Its minimally invasive approach and the favorable short-term outcome have led to rapid adoption of the technique throughout the world. As with any new technique, there will be adverse events, and it is important that effective treatments for these adverse events be discussed. We present a case of successful endoscopic management of an intramural sinus leak after a POEM procedure using tandem fully covered esophageal stents. PMID:27921057

  17. Preoperative endoscopic titanium clip placement facilitates intraoperative localization of early-stage esophageal cancer or severe dysplasia.

    PubMed

    Tan, Lei; Feng, Juan; Zhao, Qin; Chen, Ping; Yang, Guotao

    2017-08-02

    Accurate intraoperative localization of esophageal lesions is essential for successful surgical resection. We tested whether preoperative endoscopic placement of titanium clips could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. A prospective randomized clinical trial was performed between May 2012 and July 2014. All enrolled patients received preoperative endoscopy and esophageal endoscopic ultrasound, as well as pathological study on the biopsy specimen, to confirm early stage esophageal cancer or severe dysplasia. One day before the surgical operation, patients in the experimental group received the preoperative endoscopic titanium labeling of esophageal lesions. Then, during the surgical operation, palpitation of titanium clips was used to localize the lesions in these patients. In patients in the control group, palpitation of nodules or esophageal wall mucosal thickening, together with the consideration of the results from preoperative endoscopic and ultrasound studies, was applied to estimate the location of the esophageal lesions. Study outcomes included the proportions of patients having successful intraoperative pre-resection lesion localization, post-esophagectomy lesion visualization, negative upper surgical margin, change of surgical approaches, and positive postoperative pathological diagnosis. A total of 27 patients were enrolled into the study, with 14 in the experimental group and 13 in the control group. Compared to the patients in the control group, a higher proportion of patients in the experimental group had statistically significant successful intraoperative esophageal lesion localization (100 versus 15.3% in the experimental versus control group). Preoperative endoscopic titanium clip placement could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. Current study was registered in Chinese Clinical Trial Registry and World Health Organization International

  18. Repair of esophageal atresia with proximal fistula using endoscopic magnetic compression anastomosis (magnamosis) after staged lengthening.

    PubMed

    Dorman, Robert M; Vali, Kaveh; Harmon, Carroll M; Zaritzky, Mario; Bass, Kathryn D

    2016-05-01

    We describe the treatment of a patient with long-gap esophageal atresia with an upper pouch fistula, mircogastria and minimal distal esophageal remnant. After 4.5 months of feeding via gastrostomy, a proximal fistula was identified by bronchoscopy and a thoracoscopic modified Foker procedure was performed reducing the gap from approximately 7-5 cm over 2 weeks of traction. A second stage to ligate the fistula and suture approximate the proximal and distal esophagus resulted in a gap of 1.5 cm. IRB and FDA approval was then obtained for endoscopic placement of 10-French catheter mounted magnets in the proximal and distal pouches promoting a magnetic compression anastomosis (magnamosis). Magnetic coupling occurred at 4 days and after magnet removal at 13 days an esophagram demonstrated a 10 French channel without leak. Serial endoscopic balloon dilation has allowed drainage of swallowed secretions as the baby learns bottling behavior at home.

  19. Co-infection with Helicobacter pylori and Epstein-Barr virus in benign upper digestive diseases: An endoscopic and serologic pilot study.

    PubMed

    Buzás, György M; Konderák, Judith

    2016-06-01

    Some gastric cancers are Epstein-Barr virus associated. To assess the prevalence of Helicobacter pylori and viral co-infection in benign upper digestive diseases. One hundred and four outpatients were included in a prospective endoscopic-serologic study. Epstein-Barr virus immunoglobulin G (IgG), immunoglobulin M and viral capsid antigen titres were assayed with an ELISA test. Helicobacter pylori was determined by the modified Giemsa stain and by IgG-chemiluminescence. The overall prevalence of Helicobacter pylori was 56.7%. Duodenal ulcer patients were infected in 72.5 % of the cases, with the prevalence being 33.3% in functional dyspepsia (p = 0.0008) and 25.8% in reflux patients (p = 0.0001). Epstein-Barr virus IgG was detected in 70.1% of the whole group, 75% of duodenal ulcer patients, 51.2% of functional dyspepsia patients (p = 0.04) and 51.6% of the reflux disease cases (p = 0.04). Co-infection with both agents was detected in 60% of duodenal ulcer patients, 18.1% of functional dyspepsia (p = 0.00014) and 12.9% of reflux disease patients (p = 0.00012). Anti-viral IgG titre displayed a 31.7 ± 3.0 cut-off index in duodenal ulcer, 20.5 ± 3.5 in functional dyspepsia (p = 0.01) and 21.4 ± 3.6 in reflux cases (p = 0.03). Both Helicobacter pylori and Epstein-Barr virus, and co-infection with these agents, were significantly more prevalent in duodenal ulcer patients than in dyspeptic/reflux patients.

  20. [Comparison between Endoscopic Therapy and Medical Therapy in Peptic Ulcer Patients with Adherent Clot: A Multicenter Prospective Observational Cohort Study].

    PubMed

    Kim, Si Hye; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young; Lee, Dong Wook; Jeon, Seong Woo; Park, Kyung Sik; Lee, Si Hyung; Park, Jeong Bae; Ha, Chang Yoon; Park, Youn Sun

    2015-08-01

    The optimal management of bleeding peptic ulcer with adherent clot remains controversial. The purpose of this study was to compare clinical outcome between endoscopic therapy and medical therapy. We also evaluated the risk factors of rebleeding in Forrest type IIB peptic ulcer. Upper gastrointestinal (UGI) bleeding registry data from 8 hospitals in Korea between February 2011 and December 2013 were reviewed and categorized according to the Forrest classification. Patients with acute UGI bleeding from peptic ulcer with adherent clots were enrolled. Among a total of 1,101 patients diagnosed with peptic ulcer bleeding, 126 bleedings (11.4%) were classified as Forrest type IIB. Of the 126 patients with adherent clots, 84 (66.7%) received endoscopic therapy and 42 (33.3%) were managed with medical therapy alone. The baseline characteristics of patients in two groups were similar except for higher Glasgow Blatchford Score and pre-endoscopic Rockall score in medical therapy group. Bleeding related mortality (1.2% vs.10%; p=0.018) and all cause mortality (3.7% vs. 20.0%; p=0.005) were significantly lower in the endoscopic therapy group. However, there was no difference between endoscopic therapy and medical therapy regarding rebleeding (7.1% vs. 9.5%; p=0.641). In multivariate analysis, independent risk factors of rebleeding were previous medication with aspirin and/or NSAID (OR, 13.1; p=0.025). In patients with Forrest type IIB peptic ulcer bleeding, endoscopic therapy was associated with a significant reduction in bleeding related mortality and all cause mortality compared with medical therapy alone. Important risk factor of rebleeding was use of aspirin and/or NSAID.

  1. Endoscopic versus open bursectomy of lateral malleolar bursitis.

    PubMed

    Choi, Jae Hyuck; Lee, Kyung Tai; Lee, Young Koo; Kim, Dong Hyun; Kim, Jeong Ryoul; Chung, Woo Chull; Cha, Seung Do

    2012-06-01

    Compare the result of endoscopic versus open bursectomy in lateral malleolar bursitis. Prospective evaluation of 21 patients (22 ankles) undergoing either open or endoscopic excision of lateral malleolar bursitis. The median age was 64 (38-79) years old. The median postoperative follow-up was 15 (12-18) months. Those patients undergoing endoscopic excision showed a higher satisfaction rate (excellent 9, good 2) than open excision (excellent 4, good 3, fair 1). The wounds also healed earlier in the endoscopic group although the operation time was slightly longer. One patient in the endoscopic group had recurrence of symptoms but complications in the open group included one patient with skin necrosis, one patient with wound dehiscence, and two patients of with superficial peroneal nerve injury. Endoscopic resection of the lateral malleolar bursitis is a promising technique and shows favorable results compared to the open resection. Therapeutic studies-Investigating the result of treatment, Level II.

  2. Infraorbital nerve transposition to expand the endoscopic transnasal maxillectomy.

    PubMed

    Salzano, Giovanni; Turri-Zanoni, Mario; Karligkiotis, Apostolos; Zocchi, Jacopo; Dell'Aversana Orabona, Giovanni; Califano, Luigi; Battaglia, Paolo; Castelnuovo, Paolo

    2017-02-01

    The infraorbital nerve (ION) is a terminal branch of the maxillary nerve (V2) providing sensory innervation to the malar skin. It is sometimes necessary to sacrifice the ION and its branches to obtain adequate maxillary sinus exposure for radical resection of sinonasal tumors. Consequently, patients suffer temporary or permanent paresthesia, hypoestesthia, and neuralgia of the face. We describe an innovative technique used for preservation of the ION while removing the anterior, superior, and lateral walls of the maxillary sinus through a medial endoscopic transnasal maxillectomy. All patients who underwent transnasal endoscopic maxillectomy with ION transposition in our institute were retrospectively reviewed. Two patients were identified who had been treated for sinonasal cancers using this approach. No major complications were observed. Transient loss of ION function was observed with complete recovery of skin sensory perception within 6 months of surgery. One patient referred to a mild permanent anesthesia of the upper incisors. No diplopia or enophthalmos were encountered in any of the patients. The ION transposition is useful for selected cases of benign and malignant sinonasal tumors that do not infiltrate the ION itself but involve the surrounding portion of the maxillary sinus. Anatomic preservation of the ION seems to be beneficial to the postoperative quality of life of such patients. © 2016 ARS-AAOA, LLC.

  3. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  4. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  5. Developing an instrument to assess the endoscopic severity of ulcerative colitis: the Ulcerative Colitis Endoscopic Index of Severity (UCEIS).

    PubMed

    Travis, Simon P L; Schnell, Dan; Krzeski, Piotr; Abreu, Maria T; Altman, Douglas G; Colombel, Jean-Frédéric; Feagan, Brian G; Hanauer, Stephen B; Lémann, Marc; Lichtenstein, Gary R; Marteau, Phillippe R; Reinisch, Walter; Sands, Bruce E; Yacyshyn, Bruce R; Bernhardt, Christian A; Mary, Jean-Yves; Sandborn, William J

    2012-04-01

    Variability in endoscopic assessment necessitates rigorous investigation of descriptors for scoring severity of ulcerative colitis (UC). To evaluate variation in the overall endoscopic assessment of severity, the intra- and interindividual variation of descriptive terms and to create an Ulcerative Colitis Endoscopic Index of Severity which could be validated. A two-phase study used a library of 670 video sigmoidoscopies from patients with Mayo Clinic scores 0-11, supplemented by 10 videos from five people without UC and five hospitalised patients with acute severe UC. In phase 1, each of 10 investigators viewed 16/24 videos to assess agreement on the Baron score with a central reader and agreed definitions of 10 endoscopic descriptors. In phase 2, each of 30 different investigators rated 25/60 different videos for the descriptors and assessed overall severity on a 0-100 visual analogue scale. κ Statistics tested inter- and intraobserver variability for each descriptor. A general linear mixed regression model based on logit link and β distribution of variance was used to predict overall endoscopic severity from descriptors. There was 76% agreement for 'severe', but 27% agreement for 'normal' appearances between phase I investigators and the central reader. In phase 2, weighted κ values ranged from 0.34 to 0.65 and 0.30 to 0.45 within and between observers for the 10 descriptors. The final model incorporated vascular pattern, (normal/patchy/complete obliteration) bleeding (none/mucosal/luminal mild/luminal moderate or severe), erosions and ulcers (none/erosions/superficial/deep), each with precise definitions, which explained 90% of the variance (pR(2), Akaike Information Criterion) in the overall assessment of endoscopic severity, predictions varying from 4 to 93 on a 100-point scale (from normal to worst endoscopic severity). The Ulcerative Colitis Endoscopic Index of Severity accurately predicts overall assessment of endoscopic severity of UC. Validity and

  6. Ultrasound-assisted endoscopic partial plantar fascia release.

    PubMed

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  7. Ultrasound-Assisted Endoscopic Partial Plantar Fascia Release

    PubMed Central

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure. PMID:24265989

  8. Is endoscopic nodular gastritis associated with premalignant lesions?

    PubMed

    Niknam, R; Manafi, A; Maghbool, M; Kouhpayeh, A; Mahmoudi, L

    2015-06-01

    Nodularity on the gastric mucosa is occasionally seen in general practice. There is no consensus about the association of nodular gastritis and histological premalignant lesions. This study is designed to investigate the prevalence of histological premalignant lesions in dyspeptic patients with endoscopic nodular gastritis. Consecutive patients with endoscopic nodular gastritis were compared with an age- and sex-matched control group. Endoscopic nodular gastritis was defined as a miliary nodular appearance of the gastric mucosa on endoscopy. Biopsy samples of stomach tissue were examined for the presence of atrophic gastritis, intestinal metaplasia, and dysplasia. The presence of Helicobacter pylori infection was determined by histology. From 5366 evaluated patients, a total of 273 patients with endoscopic nodular gastritis and 1103 participants as control group were enrolled. H. pylori infection was detected in 87.5% of the patients with endoscopic nodular gastritis, whereas 73.8% of the control group were positive for H. pylori (p < 0.001). Prevalence of incomplete intestinal metaplasia (p = 0.016) and dysplasia (p < 0.001) in patients with endoscopic nodular gastritis were significantly higher than in the control group. Prevalence of atrophic gastritis and complete intestinal metaplasia were also more frequent in patients with endoscopic nodular gastritis than in the control group. Dysplasia, incomplete intestinal metaplasia and H. pylori infection are significantly more frequent in patients with endoscopic nodular gastritis. Although further studies are needed before a clear conclusion can be reached, we suggest that endoscopic nodular gastritis might serve as a premalignant lesion and could be biopsied in all patients for the possibility of histological premalignancy, in addition to H. pylori infection.

  9. Surveillance of Endoscopes: Comparison of Different Sampling Techniques.

    PubMed

    Cattoir, Lien; Vanzieleghem, Thomas; Florin, Lisa; Helleputte, Tania; De Vos, Martine; Verhasselt, Bruno; Boelens, Jerina; Leroux-Roels, Isabel

    2017-09-01

    OBJECTIVE To compare different techniques of endoscope sampling to assess residual bacterial contamination. DESIGN Diagnostic study. SETTING The endoscopy unit of an 1,100-bed university hospital performing ~13,000 endoscopic procedures annually. METHODS In total, 4 sampling techniques, combining flushing fluid with or without a commercial endoscope brush, were compared in an endoscope model. Based on these results, sterile physiological saline flushing with or without PULL THRU brush was selected for evaluation on 40 flexible endoscopes by adenosine triphosphate (ATP) measurement and bacterial culture. Acceptance criteria from the French National guideline (<25 colony-forming units [CFU] per endoscope and absence of indicator microorganisms) were used as part of the evaluation. RESULTS On biofilm-coated PTFE tubes, physiological saline in combination with a PULL THRU brush generated higher mean ATP values (2,579 relative light units [RLU]) compared with saline alone (1,436 RLU; P=.047). In the endoscope samples, culture yield using saline plus the PULL THRU (mean, 43 CFU; range, 1-400 CFU) was significantly higher than that of saline alone (mean, 17 CFU; range, 0-500 CFU; P<.001). In samples obtained using the saline+PULL THRU brush method, ATP values of samples classified as unacceptable were significantly higher than those of samples classified as acceptable (P=.001). CONCLUSION Physiological saline flushing combined with PULL THRU brush to sample endoscopes generated higher ATP values and increased the yield of microbial surveillance culture. Consequently, the acceptance rate of endoscopes based on a defined CFU limit was significantly lower when the saline+PULL THRU method was used instead of saline alone. Infect Control Hosp Epidemiol 2017;38:1062-1069.

  10. Advanced endoscopic imaging to improve adenoma detection

    PubMed Central

    Neumann, Helmut; Nägel, Andreas; Buda, Andrea

    2015-01-01

    Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092

  11. An ingested mobile phone in the stomach may not be amenable to safe endoscopic removal using current therapeutic devices: A case report.

    PubMed

    Obinwa, Obinna; Cooper, David; O'Riordan, James M

    2016-01-01

    This case report is intended to inform clinicians, endoscopists, policy makers and industry of our experience in the management of a rare case of mobile phone ingestion. A 29-year-old prisoner presented to the Emergency Department with vomiting, ten hours after he claimed to have swallowed a mobile phone. Clinical examination was unremarkable. Both initial and repeat abdominal radiographs eight hours later confirmed that the foreign body remained in situ in the stomach and had not progressed along the gastrointestinal tract. Based on these findings, upper endoscopy was performed under general anaesthesia. The object could not be aligned correctly to accommodate endoscopic removal using current retrieval devices. Following unsuccessful endoscopy, an upper midline laparotomy was performed and the phone was delivered through an anterior gastrotomy, away from the pylorus. The patient made an uneventful recovery and underwent psychological counselling prior to discharge. In this case report, the use of endoscopy in the management when a conservative approach fails is questioned. Can the current endoscopic retrieval devices be improved to limit the need for surgical interventions in future cases? An ingested mobile phone in the stomach may not be amenable for removal using the current endoscopic retrieval devices. Improvements in overtubes or additional modifications of existing retrieval devices to ensure adequate alignment for removal without injuring the oesophagus are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes.

    PubMed

    Qiu, Tian; Adams, Fabian; Palagi, Stefano; Melde, Kai; Mark, Andrew; Wetterauer, Ulrich; Miernik, Arkadiusz; Fischer, Peer

    2017-12-13

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues.

  13. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes

    PubMed Central

    2017-01-01

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues. PMID:29148713

  14. Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.

    PubMed

    Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J

    2016-11-01

    During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Innovative surgical endoscopes in video-assisted thoracic surgery

    PubMed Central

    Cheng, Truman; Ng, Calvin S. H.

    2018-01-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints. PMID:29732196

  16. Innovative surgical endoscopes in video-assisted thoracic surgery.

    PubMed

    Cheng, Truman; Ng, Calvin S H; Li, Zheng

    2018-04-01

    In the past three decades, rod lens endoscopes had facilitated the development and wide spread applications of video-assisted thoracic surgery (VATS). With the rise of uniportal VATS in recent years, innovations in surgical instruments should once again complement the advancement in surgical technique. While articulated flexible endoscopes have expand the field of view, and can alter viewing direction with minimal maneuvers, they still suffer from problems like trocar crowding and interference with other instruments. Magnetic anchored endoscopes, on the other hand, may provide unique benefits to VATS by replacing the endoscope rigid rod body with magnetic linkage, thus overcoming the challenge of port crowding in single incision surgery. Most magnetic anchored endoscopes reported in literature are not designed for thoracic surgeries. Many of these designs do not allow tilting of endoscopic view, rely on micromotors for actuation, or are ergonomically unfit to be operated within the spatial constraints seen in VATS application. Considering these limitations, we have designed two novel magnetic anchored and steered endoscopes targeted for uniportal VATS. Both designs could be wirelessly actuated by magnetic interaction. One has a silicone rubber formed soft body for compactness, lightweight and safety, while another is a 40 mm long capsule optimized for VATS spatial constraints.

  17. A technical review of flexible endoscopic multitasking platforms.

    PubMed

    Yeung, Baldwin Po Man; Gourlay, Terence

    2012-01-01

    Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of

  18. Endoscopic management of difficult common bile duct stones

    PubMed Central

    Trikudanathan, Guru; Navaneethan, Udayakumar; Parsi, Mansour A

    2013-01-01

    Endoscopy is widely accepted as the first treatment option in the management of bile duct stones. In this review we focus on the alternative endoscopic modalities for the management of difficult common bile duct stones. Most biliary stones can be removed with an extraction balloon, extraction basket or mechanical lithotripsy after endoscopic sphincterotomy. Endoscopic papillary balloon dilation with or without endoscopic sphincterotomy or mechanical lithotripsy has been shown to be effective for management of difficult to remove bile duct stones in selected patients. Ductal clearance can be safely achieved with peroral cholangioscopy guided laser or electrohydraulic lithotripsy in most cases where other endoscopic treatment modalities have failed. Biliary stenting may be an alternative treatment option for frail and elderly patients or those with serious co morbidities. PMID:23345939

  19. [Longterm controls after endoscopic papillotomy [EPT] (author's transl)].

    PubMed

    Burmeister, W; Wurbs, D; Hagenmüller, F; Classen, M

    1980-10-01

    In 117 patients who have undergone endoscopic papillotomy (EPT) long term controls have been done. 51 were controlled in the hospital and 66 did answer a questionnaire. The mean time interval to the EPT was mean = 21.6 months. Nine out of every ten patients had no complaints. One third had minimal changes of laboratory dates, which can easily be explained by second diseases. With nearly no exception there was a large orifice to the common bile duct at the upper brim of the papilla. There was no bilioduodenal pressure gradient in 75%. Duodenobiliary reflux could be demonstrated in 25% and aerobilia in 65%. Although there was a massive bacteriobilia in all cases, no signs of cholangitis could be found in any patient. As a result, no unfavourable effects of the EPT became obvious during this follow-up study.

  20. Role of enhanced multi-detector-row computed tomography before urgent endoscopy in acute upper gastrointestinal bleeding.

    PubMed

    Miyaoka, Youichi; Amano, Yuji; Ueno, Sayaka; Izumi, Daisuke; Mikami, Hironobu; Yazaki, Tomotaka; Okimoto, Eiko; Sonoyama, Takayuki; Ito, Satoko; Fujishiro, Hirofumi; Kohge, Naruaki; Imaoka, Tomonori

    2014-04-01

    Multi-detector-row computed tomography (MDCT) has been reported to be a potentially useful modality for detection of the bleeding origin in patients with acute upper massive gastrointestinal (GI) bleeding. The purpose of this study is to investigate the efficacy of MDCT as a routine method for detecting the origin of acute upper GI bleeding prior to urgent endoscopy. Five hundred seventy-seven patients with acute upper GI bleeding (514 nonvariceal patients, 63 variceal patients) who underwent urgent upper GI endoscopy were retrospectively analyzed. Patients were divided into three groups: enhanced MDCT, unenhanced MDCT, and no MDCT before endoscopy. The diagnostic accuracy of MDCT for detection of the bleeding origin was evaluated, and the average procedure times needed to endoscopically identify the bleeding origin were compared between groups. Diagnostic accuracy among endoscopists was 55.3% and 14.7% for the enhanced MDCT and unenhanced MDCT groups, respectively. Among nonvariceal patients, accuracy was 50.2% in the enhanced MDCT group, which was significantly better than that in the unenhanced MDCT group (16.5%). In variceal patients, accuracy was significantly better in the enhanced MDCT group (96.4%) than in the unenhanced MDCT group (0.0%). These accuracies were similar to those achieved by expert radiologists. The average procedure time to endoscopic detection of the bleeding origin in the enhanced MDCT group was significantly faster than that in the unenhanced MDCT and no-MDCT groups. Enhanced MDCT preceding urgent endoscopy may be an effective modality for the detection of bleeding origin in patients with acute upper GI bleeding. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  1. Balancing the shortcomings of microscope and endoscope: endoscope-assisted technique in microsurgical removal of recurrent epidermoid cysts in the posterior fossa.

    PubMed

    Ebner, F H; Roser, F; Thaher, F; Schittenhelm, J; Tatagiba, M

    2010-10-01

    We report about endoscope-assisted surgery of epidermoid cysts in the posterior fossa focusing on the application of neuro-endoscopy and the clinical outcome in cases of recurrent epidermoid cysts. 25 consecutively operated patients with an epidermoid cyst in the posterior fossa were retrospectively analysed. Surgeries were performed both with an operating microscope (OPMI Pentero or NC 4, Zeiss Company, Oberkochen, Germany) and endoscopic equipment (4 mm rigid endoscopes with 30° and 70° optics; Karl Storz Company, Tuttlingen, Germany) under continuous intraoperative monitoring. Surgical reports and DVD-recordings were evaluated for identification of adhesion areas and surgical details. 7 (28%) of the 25 patients were recurrences of previously operated epidermoid cysts. Mean time to recurrence was 17 years (8-22 years). In 5 cases the endoscope was used as an adjunctive tool for inspection/endoscope-assisted removal of remnants. The effective time of use of the endoscope was limited to the end stage of the procedure, but was very effective. In a modern operative setting and with the necessary surgical experience recurrent epidermoid cysts may be removed with excellent clinical results. The combined use of microscope and endoscope offers relevant advantages in demanding anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Endoscopic Radiofrequency Ablation-Assisted Resection of Juvenile Nasopharyngeal Angiofibroma: Comparison with Traditional Endoscopic Technique.

    PubMed

    McLaughlin, Eamon J; Cunningham, Michael J; Kazahaya, Ken; Hsing, Julianna; Kawai, Kosuke; Adil, Eelam A

    2016-06-01

    To evaluate the feasibility of radiofrequency surgical instrumentation for endoscopic resection of juvenile nasopharyngeal angiofibroma (JNA) and to test the hypothesis that endoscopic radiofrequency ablation-assisted (RFA) resection will have superior intraoperative and/or postoperative outcomes as compared with traditional endoscopic (TE) resection techniques. Case series with chart review. Two tertiary care pediatric hospitals. Twenty-nine pediatric patients who underwent endoscopic transnasal resection of JNA from January 2000 to December 2014. Twenty-nine patients underwent RFA (n = 13) or TE (n = 16) JNA resection over the 15-year study period. Mean patient age was not statistically different between the 2 groups (P = .41); neither was their University of Pittsburgh Medical Center classification stage (P = .79). All patients underwent preoperative embolization. Mean operative times were not statistically different (P = .29). Mean intraoperative blood loss and the need for a transfusion were also not statistically different (P = .27 and .47, respectively). Length of hospital stay was not statistically different (P = .46). Recurrence rates did not differ between groups (P = .99) over a mean follow-up period of 2.3 years. There were no significant differences between RFA and TE resection in intraoperative or postoperative outcome parameters. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  3. Design of a handheld optical coherence microscopy endoscope

    NASA Astrophysics Data System (ADS)

    Korde, Vrushali R.; Liebmann, Erica; Barton, Jennifer K.

    2011-06-01

    Optical coherence microscopy (OCM) combines coherence gating, high numerical aperture optics, and a fiber-core pinhole to provide high axial and lateral resolution with relatively large depth of imaging. We present a handheld rigid OCM endoscope designed for small animal surgical imaging, with a 6-mm diam tip, 1-mm scan width, and 1-mm imaging depth. X-Y scanning is performed distally with mirrors mounted to micro galvonometer scanners incorporated into the endoscope handle. The endoscope optical design consists of scanning doublets, an afocal Hopkins relay lens system, a 0.4 numerical aperture water immersion objective, and a cover glass. This endoscope can resolve laterally a 1.4-μm line pair feature and has an axial resolution (full width half maximum) of 5.4 μm. Images taken with this endoscope of fresh ex-vivo mouse ovaries show structural features, such as corpus luteum, primary follicles, growing follicles, and fallopian tubes. This rigid handheld OCM endoscope can be useful for a variety of minimally invasive and surgical imaging applications.

  4. Incidence of bacteremia in cirrhotic patients undergoing upper endoscopic ultrasonography.

    PubMed

    Fernández-Esparrach, Gloria; Sendino, Oriol; Araujo, Isis; Pellisé, Maria; Almela, Manel; González-Suárez, Begoña; López-Cerón, María; Córdova, Henry; Sanabria, Erwin; Uchima, Hugo; Llach, Josep; Ginès, Àngels

    2014-01-01

    The incidence of bacteremia after endoscopic ultrasonography (EUS) or EUS-guided fine-needle aspiration (EUS-FNA) is between 0% and 4%, but there are no data on this topic in cirrhotic patients. To prospectively assess the incidence of bacteremia in cirrhotic patients undergoing EUS and EUS-FNA. We enrolled 41 cirrhotic patients. Of these, 16 (39%) also underwent EUS-FNA. Blood cultures were obtained before and at 5 and 30 min after the procedure. When EUS-FNA was used, an extra blood culture was obtained after the conclusion of radial EUS and before the introduction of the sectorial echoendoscope. All patients were clinically followed up for 7 days for signs of infection. Blood cultures were positive in 16 patients. In 10 patients, blood cultures grew coagulase-negative Staphylococcus, Corynebacterium species, Propionibacterium species or Acinetobacterium Lwoffii, which were considered contaminants (contamination rate 9.8%, 95% CI: 5.7-16%). The remaining 6 patients had true positive blood cultures and were considered to have had true bacteremia (15%, 95% CI: 4-26%). Blood cultures were positive after diagnostic EUS in five patients but were positive after EUS-FNA in only one patient. Thus, the frequency of bacteremia after EUS and EUS-FNA was 12% and 6%, respectively (95% CI: 2-22% and 0.2-30%, respectively). Only one of the patients who developed bacteremia after EUS had a self-limiting fever with no other signs of infection. Asymptomatic Gram-positive bacteremia developed in cirrhotic patients after EUS and EUS-FNA at a rate higher than in non-cirrhotic patients. However, this finding was not associated with any clinically significant infections. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  5. Endoscopic ampullectomy: a practical guide

    PubMed Central

    Bassan, Milan

    2012-01-01

    Endoscopic ampullectomy is a minimally invasive method of treating superficial lesions of the ampulla of Vater. With careful patient selection and lesion assessment it is a safe and efficacious therapeutic procedure that can obviate the need for potentially major surgical intervention. Strategies for safe and successful endoscopic ampullectomy with a focus on resection technique and recognition and management of complications are presented. PMID:22586547

  6. Endoscopic Therapies for Chronic Pancreatitis.

    PubMed

    Adler, Jeffrey M; Gardner, Timothy B

    2017-07-01

    Chronic pancreatitis is a fibroinflammatory disease of the pancreas leading to varying degrees of endocrine and exocrine dysfunction. Treatment options are generally designed to control the pain of chronic pancreatitis, and endoscopic therapy is one of the main treatment modalities. Herein, we describe the endoscopic management of pancreatic duct calculi and strictures, entrapment of the intrapancreatic bile duct, celiac plexus interventions, and drainage of pancreatic pseudocysts.

  7. Prospective, randomized comparison of a prototype endoscope with deflecting working channels versus a conventional double-channel endoscope for rectal endoscopic submucosal dissection in an established experimental simulation model (with video).

    PubMed

    Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2013-11-01

    A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-06-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary.

  9. Elimination of high titre HIV from fibreoptic endoscopes.

    PubMed Central

    Hanson, P J; Gor, D; Jeffries, D J; Collins, J V

    1990-01-01

    Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary. PMID:2379868

  10. Endoscopic optical coherence tomography: technologies and clinical applications [Invited

    PubMed Central

    Gora, Michalina J.; Suter, Melissa J.; Tearney, Guillermo J.; Li, Xingde

    2017-01-01

    In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed. PMID:28663882

  11. Working channel endoscope in lumbar spine surgery.

    PubMed

    Choi, G; Lee, S H; Deshpande, K; Choi, H

    2014-06-01

    Percutaneous endoscopic lumbar discectomy (PELD) is a well established modality in the treatment of patients with herniated lumbar discs. Since the time of its inception towards the end of 20th century, this technique has undergone significant modifications. With better understanding of the patho-anatomy and development of instrumentation the indications for PELD are on the rise. In the modern era of knowledge exchange there have been considerable variations among different endoscopic surgeons about classical indications and the implications of a particular technique pertaining to those indications. During last 15 years of experience in practicing endoscopic surgery, Choi has published many articles, regarding the techniques of PELD, across many scientific journals. In our practice there has been considerable shift from central debulking to discectomy to selective fragmentectomy. With further advancements the span of this technique is definitely on the rise. Here, we wish to share all the published data along with my current practice trends in more precise manner to help newer endoscopic spine surgeons understand the implications and limitations of a working channel endoscope in lumbar spine pathologies.

  12. Limits of the endoscopic transnasal transtubercular approach.

    PubMed

    Gellner, Verena; Tomazic, Peter V

    2018-06-01

    The endoscopic transnasal trans-sphenoidal transtubercular approach has become a standard alternative approach to neurosurgical transcranial routes for lesions of the anterior skull base in particular pathologies of the anterior tubercle, sphenoid plane, and midline lesions up to the interpeduncular cistern. For both the endoscopic and the transcranial approach indications must strictly be evaluated and tailored to the patients' morphology and condition. The purpose of this review was to evaluate the evidence in literature of the limitations of the endoscopic transtubercular approach. A PubMed/Medline search was conducted in January 2018 entering following keywords. Upon initial screening 7 papers were included in this review. There are several other papers describing the endoscopic transtubercular approach (ETTA). We tried to list the limitation factors according to the actual existing literature as cited. The main limiting factors are laterally extending lesions in relation to the optic canal and vascular encasement and/or unfavorable tumor tissue consistency. The ETTA is considered as a high level transnasal endoscopic extended skull base approach and requires excellent training, skills and experience.

  13. The endoscopic stapler diverticulotomy for Zenker's diverticulum.

    PubMed

    Manni, Johannes J; Kremer, Bernd; Rinkel, Rico N P M

    2004-02-01

    This paper describes the surgical procedure of the endoscopic stapler treatment of Zenker's diverticulum and analyzes the results of 24 consecutive operated patients. In three patients the endoscopic exposure of the diverticulum was not possible. Twenty-one patients underwent endoscopic stapler treatment without any peri- or postoperative complications. The follow-up period was 4 to 29 months (average 18 months). The average total time for surgery was 25 min. Postoperatively, a nasogastric feeding tube was not necessary: all patients resumed oral intake 12 h after surgery. Discharge from the hospital followed the 2nd postoperative day. All patients had complete or nearly complete resolution of symptoms at the 4-month follow-up. Recurrent complaints were an indication for repeat of the contrast barium esophagram. Two patients revealed a residual diverticulum 7 and 11 months after treatment. In comparison with results and complication rates in the literature of the external, transcutaneous techniques and endoscopic diverticulotomy procedures, the endoscopic stapler treatment of Zenker's diverticulum is a safe, (cost-)effective and minimally invasive method and to be considered as the initial treatment of choice.

  14. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  15. The mechanics of endoscope disinfection.

    PubMed

    Babb, J R; Bradley, C R

    1991-06-01

    The decontamination of flexible fibreoptic endoscopes has considerably improved in recent years. This is mainly due to the introduction of instruments with more accessible channels, the use of automated washer disinfectors and a greater awareness of the problems associated with disinfection. Unfortunately the most widely used and effective disinfectant is 2% glutaraldehyde and this is toxic, irritant and sensitizing. With the implementation of Control of Substances Hazardous to Health legislation, strict environmental controls are required to reduce skin contact and vapour inhalation. Alcohol is probably the most suitable alternative disinfectant at present but it is flammable and cannot be used in automated systems. Other agents are either insufficiently effective or corrosive. Autoclavable or heat tolerant rigid endoscopes are now available but flexible endoscopes will not tolerate heat disinfection temperatures.

  16. Management of a large mucosal defect after duodenal endoscopic resection

    PubMed Central

    Fujihara, Shintaro; Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Masaki, Tsutomu

    2016-01-01

    Duodenal endoscopic resection is the most difficult type of endoscopic treatment in the gastrointestinal tract (GI) and is technically challenging because of anatomical specificities. In addition to these technical difficulties, this procedure is associated with a significantly higher rate of complication than endoscopic treatment in other parts of the GI tract. Postoperative delayed perforation and bleeding are hazardous complications, and emergency surgical intervention is sometimes required. Therefore, it is urgently necessary to establish a management protocol for preventing serious complications. For instance, the prophylactic closure of large mucosal defects after endoscopic resection may reduce the risk of hazardous complications. However, the size of mucosal defects after endoscopic submucosal dissection (ESD) is relatively large compared with the size after endoscopic mucosal resection, making it impossible to achieve complete closure using only conventional clips. The over-the-scope clip and polyglycolic acid sheets with fibrin gel make it possible to close large mucosal defects after duodenal ESD. In addition to the combination of laparoscopic surgery and endoscopic resection, endoscopic full-thickness resection holds therapeutic potential for difficult duodenal lesions and may overcome the disadvantages of endoscopic resection in the near future. This review aims to summarize the complications and closure techniques of large mucosal defects and to highlight some directions for management after duodenal endoscopic treatment. PMID:27547003

  17. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  18. Endoscopic manometry of the sphincter of Oddi in sphincterotomized patients.

    PubMed

    Ugljesić, M; Bulajić, M; Milosavljević, T; Stimec, B

    1995-01-01

    Endoscopic sphincterotomy (ES) of the sphincter of Oddi (SO) has been accepted as an effective method in extraction of common bile duct stones in postcholecystectomy patients. The purpose of this study was to examine the completeness of the performed ES and observe the post sphincterotomy pancreatic duct sphincter (PDS) activity using endoscopic manometry. Activity of the sphincter of Oddi was examined in 15 sphincterotomized patients using endoscopic manometry one to 2.5 years after endoscopic sphincterotomy for choledocholithiasis. In eight patients absence of choledochoduodenal gradient, baseline pressure and the sphincter of Oddi phasic activity up to 2.5 years after endoscopic sphincterotomy indicated a complete sphincterotomy. In seven patients with incomplete endoscopic sphincterotomy, manometry exhibited either a lower choledochoduodenal gradient and baseline pressure without phasic activity of the sphincter of Oddi (three patients), a sphincter of Oddi activity without choledochoduodenal gradient (one patient), or a complete restitution of the sphincter of Oddi activity 1 to 2 years after endoscopic sphincterotomy (three patients). In five patients, with complete endoscopic sphincterotomy, measurements of pancreatic sphincter activity showed lower values of the pancreatic ductal pressure and baseline pressure, while the pancreatic sphincter phasic activity was equal to that found in the control group. Endoscopic manometry is method which enables us to test the completeness of endoscopic sphincterotomy and to follow the restitution of the phasic contractile function of the sphincter. Manometric findings reveal pancreatic sphincter in most patients as a separate sphincteric entity, the function of which is reduced but not eliminated by a complete endoscopic sphincterotomy.

  19. Survival study of natural orifice translumenal endoscopic surgery for rectosigmoid resection using transanal endoscopic microsurgery with or without transgastric endoscopic assistance in a swine model.

    PubMed

    Sylla, Patricia; Sohn, Dae Kyung; Cizginer, Sevdenur; Konuk, Yusuf; Turner, Brian G; Gee, Denise W; Willingham, Field F; Hsu, Maylee; Mino-Kenudson, Mari; Brugge, William R; Rattner, David W

    2010-08-01

    The feasibility of transanal rectosigmoid resection with transanal endoscopic microsurgery (TEM) was previously demonstrated in a swine nonsurvival model in which transgastric endoscopic assistance also was shown to extend the length of colon mobilized transanally. A 2-week survival study evaluating transanal endoscopic rectosigmoid resection with stapled colorectal anastomosis was conducted with swine using the transanal approach alone (TEM group, n = 10) or a transanal approach combined with transgastric endoscopic assistance (TEM + TG group, n = 10). Gastrotomies were created using a needleknife and balloon dilation, then closed using prototype T-tags. Outcomes were evaluated and compared between the groups using Student's t-test and Fisher's exact test. Relative to the TEM group, the average length of rectosigmoid mobilized in the TEM + TG group was 15.6 versus 10.5 cm (p < 0.0005), the length of the resected specimen was 9 versus 6.2 cm (p < 0.0005), and the mean operative time was 254.5 versus 97.5 min (p < 0.0005). Intraoperatively, no organ injury or major bleeding was noted. Two T-tag misfires occurred during gastrotomy closure and four small staple line defects requiring transanal repair including one in the TEM group and three in the TEM + TG group (p = 0.2). Postoperatively, there was no mortality, and the animals gained an average of 3.4 lb. Two major complications (10%) were identified at necropsy in the TEM + TG group including an intraabdominal abscess and an abdominal wall hematoma related to T-tag misfire. Gastrotomy closure sites and colorectal anastomoses were all grossly healed, with adhesions noted in 60 and 70% and microabscesses in 50 and 20% of the gastrotomy sites and colorectal anastomoses, respectively. Natural orifice translumenal endoscopic surgery (NOTES) for rectosigmoid resection using TEM with or without transgastric endoscopic assistance is feasible and associated with low morbidity in a porcine survival model. Transgastric

  20. [TITANIUM NICKELIDE TECHNOLOGIES IN MINIMALLY INVASIVE SURGERY OF KIDNEY AND UPPER URINARY TRACT].

    PubMed

    Feofilov, L V

    2015-01-01

    The most common pathology of the kidney and upper urinary tract includes nephrolithiasis, ureteral strictures and renal cysts. In the treatment of patients with these diseases, the majority of surgeons prefer minimally invasive techniques, including endoscopic surgery. The complication rate of percutaneous surgery is a major factor in encouraging the search for new treatments. We have analyzed the results of 402 x-ray-endoscopic operations performed with the use of technologies based on titanium nickelide materials in patients with nephrolithiasis, ureteral strictures and kidney cysts. The high effectiveness and reliability of porous titanium nickelide cryoapplicator was noted in control of percutaneous channel bleeding and prevention. The proposed suspension nephropexy with fine titanium granules in coexisting nephrolithiasis and nephroptosis demonstrated 1.5 times greater effectiveness compared to the traditional nephropexy, reducing duration of nephrostomy and rehabilitation by almost 3 times. The proposed methods of intubation by permanent and temporary stents with shape memory after percutaneous ureteropelvic junction stricture correction are promising in the treatment of patients with this pathology of the upper urinary tract. Application of titanium nickelide implants in simple renal cyst surgery has led to a significant increase in the effectiveness of these operations, improvement in long-term results and patients' quality of life.

  1. 3-D endoscopic imaging using plenoptic camera.

    PubMed

    Le, Hanh N D; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel; Kang, Jin U

    2016-06-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera.

  2. The utility of endoscopic radical resection with microdissection electrodes for lingual thyroglossal duct cysts.

    PubMed

    Cho, Jung-Hae; Jung, Won-Sang; Sun, Dong-Il

    2014-03-01

    Lingual thyroglossal duct cysts (LTGDCs) are very rare and liable to be misdiagnosed as simple vallecular or mucus retention cysts. We recognized the importance of complete resection by means of the Sistrunk operation and applied the revised surgical technique to the treatment of LTGDCs. The aim of this study was to evaluate the results of surgical management of LTGDCs from the author's series and analyze its utility. Twelve patients, 10 male and 2 female, who were diagnosed with LTGDCs between January 2007 and December 2012, underwent endoscopic radical resection with microdissection electrodes. All cases were evaluated by enhanced CT and flexible laryngoscope before surgery. We reviewed the collected data including presentation, CT findings, surgical techniques, postoperative complication, and recurrence. Most adult LTGDCs presented with foreign body sensation, while one infant presented acute upper airway obstruction. All cysts abutted on the hyoid bone and were located at the midline of the posterior tongue. Endoscopic radical resection with microdissection electrodes was possible by dissecting hyoid periosteum without significant morbidity. All patients excluding 1 infant were not intubated electively overnight and went home the following morning. All patients showed no evidence of recurrence during follow-up. We found that the diagnosis of LTGDCs must be based on the anatomic relationship with the hyoid bone by enhanced sagittal neck CT. Endoscopic radical resection with microdissection electrodes can be recommended for reducing recurrence and morbidity by dissecting the hyoid perichondrium in the treatment of LTGDCs.

  3. [Rupture of splenic artery pseudoaneurysm: an unusual cause of upper gastrointetinal bleeding].

    PubMed

    Herrera-Fernández, Francisco Antonio; Palomeque-Jiménez, Antonio; Serrano-Puche, Félix; Calzado-Baeza, Salvador Francisco; Reyes-Moreno, Montserrat

    2014-01-01

    Bleeding from a pancreatic pseudocyst is a severe complication after pancreatitis that can lead to a massive gastrointestinal blood loss. Pseudocyst rupture into the stomach is an unusual complication. We report the case of a 34-year-old woman with a history of alcoholism and a pancreatic pseudocyst. One year after follow-up of her pseudocyst, she arrived at the emergency room with an episode of upper gastrointestinal bleeding. An upper digestive endoscopy showed active bleeding in the subcardial fundus, which could not be endoscopically controlled. Abdominal angio-CT confirmed the diagnosis of a splenic artery pseudoaneurysm in close contact with the back wall of the stomach, as well as a likely fistulization of it. The patient was urgently operated and a distal splenopancreatectomy and fistulorrhaphy was performed. The rupture of a splenic artery pseudoaneurysm may rarely present as upper gastrointestinal bleeding. This may be lethal if not urgently treated.

  4. Ling classification describes endoscopic progressive process of achalasia and successful peroral endoscopy myotomy prevents endoscopic progression of achalasia.

    PubMed

    Zhang, Wen-Gang; Linghu, En-Qiang; Chai, Ning-Li; Li, Hui-Kai

    2017-05-14

    To verify the hypothesis that the Ling classification describes the endoscopic progressive process of achalasia and determine the ability of successful peroral endoscopic myotomy (POEM) to prevent endoscopic progression of achalasia. We retrospectively reviewed the endoscopic findings, symptom duration, and manometric data in patients with achalasia. A total of 359 patients (197 women, 162 men) with a mean age of 42.1 years (range, 12-75 years) were evaluated. Symptom duration ranged from 2 to 360 mo, with a median of 36 mo. Patients were classified with Ling type I ( n = 119), IIa ( n = 106), IIb ( n = 60), IIc ( n = 60), or III ( n = 14), according to the Ling classification. Of the 359 patients, 349 underwent POEM, among whom 21 had an endoscopic follow-up for more than 2 years. Pre-treatment and post-treatment Ling classifications of these 21 patients were compared. Symptom duration increased significantly with increasing Ling classification (from I to III) ( P < 0.05), whereas lower esophageal sphincter pressure decreased with increasing Ling type (from I to III) ( P < 0.05). There was no difference in sex ratio or onset age among the Ling types, although the age at time of diagnosis was higher in Ling types IIc and III than in Ling types I, IIa, and IIb. Of the 21 patients, 19 underwent high-resolution manometry both before and after treatment. The mean preoperative and postoperative lower esophageal sphincter pressure were 34.6 mmHg (range, 15.3-59.4 mmHg) and 15.0 mmHg (range, 2.1-21.6 mmHg), respectively, indicating a statistically significant decrease after POEM. All of the 21 patients were treated successfully by POEM (postoperative Eckardt score ≤ 3) and still had the same Ling type during a mean follow-up period of 37.8 mo (range, 24-51 mo). The Ling classification represents the endoscopic progressive process of achalasia and may be able to serve as an endoscopic assessment criterion for achalasia. Successful POEM (Eckardt score ≤ 3) seems to have

  5. Endoscopic dacryocystorhinostomy without silicone stent.

    PubMed

    Yeon, Je Yeob; Shim, Woo Sub

    2012-06-01

    In nasolacrimal duct (NLD) obstruction patients that undergo endoscopic dacryocystorhinostomy (DCR), creation of a patent rhinostomy with adequate epithelialization can be accomplished without a stent. However, in common canalicular obstruction patients, a silicone stent seems to have a beneficial role and to bear more favorable results. The aim of this study was to evaluate the surgical outcome of endoscopic DCR without the use of a silicone stent. In all, 36 patients (41 eyes) who underwent endoscopic DCR were enrolled in this study. The patients were classified into a DCR with silicone stent group and a DCR without silicone stent group. Then each of the groups was subdivided into common canalicular obstruction group and NLD obstruction group. Surgical outcomes were evaluated by postoperative symptom improvement and patency of the rhinostomy under nasal endoscopic exam. The epiphora was improved in 84.2% of the silicone stent group and 81.8% of the non-silicone stent group. Categorized by the level of obstruction, in common canalicular obstruction, the success rate was 84.5% (11/13) in the silicone stent group and 57.1% (4/7) in the no stent group. In NLD obstruction, the success rate was 83.0% (5/6) in the silicone stent group and 93.3% (14/15) in the no stent group.

  6.  Schistosomal portal hypertension: Randomized trial comparing endoscopic therapy alone or preceded by esophagogastric devascularization and splenectomy.

    PubMed

    Costa Lacet, Celina Maria; Neto, João Batista; Ribeiro, Laercio Tenório; Oliveira, Francisco Silva; Wyszomirska, Rozangela Fernandes; Strauss, Edna

    2016-01-01

     Background. Upper gastrointestinal bleeding is a major cause of morbidity and mortality in patients with portal hypertension secondary to schistosomiasis mansoni. To evaluate the efficacy of combined surgery and sclerotherapy versus endoscopic treatment alone in the prophylaxis of esophageal variceal rebleeding due to portal hypertension in schistosomiasis. During a two-years period consecutive patients with schistosomiasis and a recent bleeding history were evaluated for prospective randomization. Absolute exclusion criteria were alcoholism or other liver diseases, whereas platelet count < 50,000/mm3, INR > 1.5 or presence of gastric varices were relative exclusion criteria. By random allocation 25 (group A) have received endoscopic sclerotherapy for esophageal varices alone and 22 (group B) combined treatment: esophagogastric devascularization with splenectomy followed by sclerotherapy. Interim analysis at 24 months has shown significant statistical differences between the groups and the randomization was halted. Mean age was 38.9 ± 15.4 years and 58.46% were male. Mean follow-up was 38.6 ± 20.1 months. Endoscopic comparison of the size of esophageal varices before and after treatment did not show significant differences among the two groups. Treatment efficacy was assessed by the rate of recurrent esophageal variceal bleeding, that was more common in group A- 9/25 patients (36.0%) vs. 2/22 (9.0%) in group B (p = 0.029). Other complications were odynophagia, dysphagia and esophageal ulcer in group A and ascites and portal vein thrombosis in the surgical group. In portal hypertension due to schistosomiasis, combined surgical and endoscopic treatment was more effective for the prevention of recurrent esophageal variceal bleeding.

  7. 3-D endoscopic imaging using plenoptic camera

    PubMed Central

    Le, Hanh N. D.; Decker, Ryan; Opferman, Justin; Kim, Peter; Krieger, Axel

    2017-01-01

    Three-dimensional endoscopic imaging using plenoptic technique combined with F-matching algorithm has been pursued in this study. A custom relay optics was designed to integrate a commercial surgical straight endoscope with a plenoptic camera. PMID:29276806

  8. Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.

    PubMed

    Chen, Min; Shen, Bo

    2015-09-01

    Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.

  9. Effects of age, gender, bolus condition, viscosity, and volume on pharyngeal and upper esophageal sphincter pressure and temporal measurements during swallowing.

    PubMed

    Butler, Susan G; Stuart, Andrew; Castell, Donald; Russell, Gregory B; Koch, Kenneth; Kemp, Shannon

    2009-02-01

    The purpose of this study was to determine the effects of trial (i.e., Trial 1 vs. Trial 2); viscosity (i.e., saliva, thin, nectar-thick, honey-thick, and pudding-thick water); volume (i.e., 5 mL vs. 10 mL); age (i.e., young vs. older adults); and gender on pharyngeal (i.e., upper and lower) and upper esophageal sphincter (UES) pressures, durations, and onsets (i.e., onset of upper pharyngeal pressures relative to onsets of UES relaxations and onset of lower relative to upper pharyngeal pressures). Twenty-three young adults (M=30 years) and 21 older healthy adults (M=75 years) participated. Measurements were acquired with a 2.1-mm catheter during simultaneous manometric and endoscopic swallowing assessment. Participants contributed 18 swallows, affording a study total of 792 swallows for analyses. There was no significant effect of trial on any measurement of pressure, duration, and onset (ps=.63, .39, and .71, respectively). It was found that viscosity, volume, age, and gender affected pressure, duration, and onset measurements (e.g., onset of upper pharyngeal pressures relative to onsets of UES relaxations) but in varying degrees relative to the location in the pharynx or UES and the type of measurement (e.g., pressure, onset). Manometric measurements vary with respect to age, gender, and bolus variables and interactions of each. Consideration of these variables is paramount in understanding normal and pathological swallowing if manometry is to develop as a quantitative adjunct to videofluoroscopic and endoscopic swallowing tools.

  10. Hybrid natural orifice transluminal endoscopic cholecystectomy: prospective human series.

    PubMed

    Cuadrado-Garcia, Angel; Noguera, Jose F; Olea-Martinez, Jose M; Morales, Rafael; Dolz, Carlos; Lozano, Luis; Vicens, Jose-Carlos; Pujol, Juan José

    2011-01-01

    Natural orifice transluminal endoscopic surgery (NOTES) makes it possible to perform intraperitoneal surgical procedures with a minimal number of access points in the abdominal wall. Currently, it is not possible to perform these interventions without the help of abdominal wall entryways, so these procedures are hybrids fusing minilaparoscopy and transluminal endoscopic surgery. This report presents a prospective clinical series of 25 patients who underwent transvaginal hybrid cholecystectomy for cholelithiasis. The study comprised a clinical series of 25 consecutive nonrandomized women who underwent a fusion transvaginal NOTES and minilaparoscopy procedure with two trocars for cholelithiasis: one 5-mm umbilical trocar and one 3-mm trocar in the upper left quadrant. The study had no control group. The scheduled surgical intervention was performed for all 25 women. No intraoperative complications occurred. One patient had mild hematuria that resolved in less than 12 h, but no other complications occurred during an average follow-up period of 140 days. Of the 25 women, 20 were discharged in 24 h, and 5 were discharged less than 12 h after the procedure. Hybrid transvaginal cholecystectomy, combining NOTES and minilaparoscopy, is a good surgical model for minimally invasive surgery. It can be performed in surgical settings where laparoscopy is practiced regularly using the instruments normally used for endoscopy and laparoscopic surgery. Due to the reproducibility of the intervention and the ease of vaginal closure, hybrid transvaginal cholecystectomy will permit further development of NOTES in the future.

  11. Endoscopic electrosurgical papillotomy and manometry in biliary tract disease.

    PubMed

    Geenen, J E; Hogan, W J; Shaffer, R D; Stewart, E T; Dodds, W J; Arndorfer, R C

    1977-05-09

    Endoscopic papillotomy was performed in 13 patients after cholecystectomy for retained or recurrent common bile duct calculi (11 patients) and a clinical picture suggesting papillary stenosis (two patients). Following endoscopic papillotomy, ten of the 11 patients spontaneously passed common bile duct (CBD) stones verified on repeated endoscopic retrograde cholangiopancreatography (ERCP) study. One patient failed to pass a large CBD calculus; one patient experienced cholangitis three months after in inadequate papillotomy and required operative intervention. Endoscopic papillotomy substantially decreased the pressure gradient existing between the CBD and the duodenum in all five patients studied with ERCP manometry. Endoscopic papillotomy is a relatively safe and effective procedure for postcholecystectomy patients with retained or recurrent CBD stones. The majority of CBD stones will pass spontaneously if the papillotomy is adequate.

  12. Comparison of three scoring systems for risk stratification in elderly patients wıth acute upper gastrointestinal bleeding.

    PubMed

    Kalkan, Çağdaş; Soykan, Irfan; Karakaya, Fatih; Tüzün, Ali; Gençtürk, Zeynep Bıyıklı

    2017-04-01

    Acute gastrointestinal bleeding is a potentially life-threatening condition that requires rapid assessment and dynamic management. Several scoring systems are used to predict mortality and rebleeding in such cases. The aim of the present study was to compare three scoring systems for predicting short-term mortality, rebleeding, duration of hospitalization and the need for blood transfusion in elderly patients with upper gastrointestinal bleeding. The present study included 335 elderly patients with upper gastrointestinal bleeding. Pre- and post-endoscopic Rockall, Glasgow-Blatchford and AIMS65 scores were calculated. The ability of these scores to predict rebleeding, mortality, duration of hospitalization and the need for blood transfusion was determined. Pre- (4.5) and post-endoscopic (7.5) Rockall scores were superior to the Glasgow-Blatchford (12.5) score for predicting mortality (P = 0.006 and P = 0.015). Likewise, pre- (4.5) and post-endoscopic Rockall scores were superior to the respective Glasgow-Blatchford scores for predicting rebleeding (P = 0.013 and P = 0.03). There was an association between duration of hospitalization and mortality; as the duration of hospitalization increased the mortality rate increased. In all, 94% of patients hospitalized for a mean of 5 days were alive versus 56.1% of those hospitalized for 20 days, and 20.2% of those hospitalized for 40 days. In elderly patients with upper gastrointestinal bleeding, the Rockall score is clinically more useful for predicting mortality and rebleeding than the Glasgow-Blatchford and AIMS65 scores; however, for predicting duration of hospitalization and the need for blood transfusion, the Glasgow-Blatchford score is superior to the Rockall and AIMS65 scores. Geriatr Gerontol Int 2017; 17: 575-583. © 2016 Japan Geriatrics Society.

  13. Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.

    PubMed

    Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong

    2017-03-01

    In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.

  14. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes.

    PubMed

    Chiu, King-Wah; Tsai, Ming-Chao; Wu, Keng-Liang; Chiu, Yi-Chun; Lin, Ming-Tzung; Hu, Tsung-Hui

    2012-09-03

    The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.

  15. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes

    PubMed Central

    2012-01-01

    Background The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. PMID:22943739

  16. Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.

    PubMed

    1994-06-01

    In this issue, we evaluate three liquid disinfecting flexible endoscope reprocessors that can be used with a user-supplied liquid chemical germicide (LCG), primarily for high-level disinfection (HLD). Applying most of the same criteria and test methods, we also evaluated a fourth unit, presented separately, that is marketed as a liquid sterilizing reprocessor and must be used with manufacturer-supplied, single-use containers of LCG. Although the sterilizing unit can be used for rigid endoscopes, surgical instruments, and endoscopic accessories, we evaluated its application to the reprocessing of only flexible endoscopes. Our ratings are based on the following: (1) basic performance, such as compatibility with several different types of endoscopes and LCGs, inclusion of all essential reprocessing phases, and exposure of all endoscope surfaces to the LCG and rinse water; (2) safety, such as ensuring that essential reprocessing phases cannot be skipped or omitted, that personnel exposure to LCG vapors is minimized, and that the reprocessor is unlikely to contaminate the endoscope during reprocessing; and (3) human factors design, such as ease of use and installation. We did not perform microbiological testing to confirm HLD or sterilization by any of the evaluated reprocessors because, with a suitably clean endoscope that is in good condition, no evidence indicates that the LCGs used would not be effective on the surfaces that they contact; also, the results would be unique to the two flexible endoscopes that we used for our testing. We rated all four reprocessors Conditionally Acceptable. The units are Acceptable on the condition that users understand that they cannot be used to process the elevator cable channel of side-viewing duodenoscopes; additional conditions apply only to the liquid disinfecting units. However, if the conditions are met, all four units reduce the likelihood of using a contaminated endoscope on a patient and reduce personnel exposure to the LCG

  17. Method for radiometric calibration of an endoscope's camera and light source

    NASA Astrophysics Data System (ADS)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  18. Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study

    PubMed Central

    Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun

    2017-01-01

    Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial

  19. Ultrahigh-resolution endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Herz, Paul R.; Hsiung, Pei-Lin; Aguirre, Aaron D.; Mashimo, Hiroshi; Desai, Saleem; Pedrosa, Macos; Koski, Amanda; Schmitt, Joseph M.; Fujimoto, James G.

    2005-01-01

    Early detection of gastrointestinal cancer is essential for the patient treatment and medical care. Endoscopically guided biopsy is currently the gold standard for the diagnosis of early esophageal cancer, but can suffer from high false negative rates due to sampling errors. Optical coherence tomography (OCT) is an emerging medical imaging technology which can generate high resolution, cross-sectional images of tissue in situ and in real time, without the removal of tissue specimen. Although endoscopic OCT has been used successfully to identify certain pathologies in the gastrointestinal tract, the resolution of current endoscopic OCT systems has been limited to 10 - 15 m for clinical procedures. In this study, in vivo imaging of the gastrointestinal tract is demonstrated at a three-fold higher resolution (< 5 m), using a portable, broadband, Cr4+:Forsterite laser as the optical light source. Images acquired from the esophagus, gastro-esophageal junction and colon on animal model display tissue microstructures and architectural details at high resolution, and the features observed in the OCT images are well-matched with histology. The clinical feasibility study is conducted through delivering OCT imaging catheter using standard endoscope. OCT images of normal esophagus, Barrett's esophagus, and esophageal cancers are demonstrated with distinct features. The ability of high resolution endoscopic OCT to image tissue morphology at an unprecedented resolution in vivo would facilitate the development of OCT as a potential imaging modality for early detection of neoplastic changes.

  20. Endoscopic management of congenital esophageal stenosis.

    PubMed

    Romeo, Erminia; Foschia, Francesca; de Angelis, Paola; Caldaro, Tamara; Federici di Abriola, Giovanni; Gambitta, Rosaalba; Buoni, Simona; Torroni, Filippo; Pardi, Valerio; Dall'oglio, Luigi

    2011-05-01

    Congenital esophageal stenosis (CES) is a rare malformation. Endoscopic dilations represent a therapeutic option. This study retrospectively evaluated the efficacy and safety of a conservative treatment of CES. Patients diagnosed with CES since 1980 by a barium study or endoscopy were reviewed. Endoscopic ultrasonography (Olympus UM-3R-20-MHz radial miniprobe, Olympus Corporation, Tokyo, Japan), available from 2001, allowed for the differential diagnosis of tracheobronchial remnants (TBR) and fibromuscular hypertrophy (FMH) CES. All children underwent conservative treatment by endoscopic dilations (hydrostatic and Savary). Forty-seven patients (20 men) had CES. Fifteen were associated with esophageal atresia; and 8, with Down syndrome. Mean age at the diagnosis was 28.3 months (range, 1 day to 146 months). Symptoms were solid food refusal, regurgitation, vomiting, and dysphagia. Congenital esophageal stenosis was located in the distal esophagus. Endoscopic ultrasonography demonstrated TBR and FMH in 6 patients. One hundred forty-eight dilations in 47 patients were performed. The stenosis healed in 45 (95.7%). Complications were 5 (10.6%) esophageal perforations, hydrostatic (3/32, or 9.3%), and Savary (2/116, or 1.7%). At follow-up, 1 patient with FMH CES and 1 patient with TBR CES required operation for persistent dysphagia. The conservative treatment yielded positive outcomes in CES. Endoscopic ultrasonography allows for a correct diagnosis of TBR/FMH CES. A surgical approach should be reserved for CES not responsive to dilations. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Endoscopic management of gastrointestinal perforations, leaks and fistulas

    PubMed Central

    Rogalski, Pawel; Daniluk, Jaroslaw; Baniukiewicz, Andrzej; Wroblewski, Eugeniusz; Dabrowski, Andrzej

    2015-01-01

    Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated with bariatric operations call for a minimally invasive treatment for these complications. The therapeutic approach can vary greatly depending on the size, location, and timing of gastrointestinal wall defect recognition. Some asymptomatic patients can be treated conservatively, while patients with septic symptoms or cardio-pulmonary insufficiency may require intensive care and urgent surgical treatment. However, most gastrointestinal wall defects can be satisfactorily treated by endoscopy. Although the initial endoscopic closure rates of chronic fistulas is very high, the long-term results of these treatments remain a clinical problem. The efficacy of endoscopic therapy depends on several factors and the best mode of treatment will depend on a precise localization of the site, the extent of the leak and the endoscopic appearance of the lesion. Many endoscopic tools for effective closure of gastrointestinal wall defects are currently available. In this review, we summarized the basic principles of the management of acute iatrogenic perforations, as well as of postoperative leaks and chronic fistulas of the gastrointestinal tract. We also described the effectiveness of various endoscopic methods based on current research and our experience. PMID:26457014

  2. Feasibility of Piezoelectric Endoscopic Transsphenoidal Craniotomy: A Cadaveric Study

    PubMed Central

    Tomazic, Peter Valentin; Gellner, Verena; Koele, Wolfgang; Hammer, Georg Philipp; Braun, Eva Maria; Gerstenberger, Claus; Clarici, Georg; Holl, Etienne; Braun, Hannes; Stammberger, Heinz; Mokry, Michael

    2014-01-01

    Objective. Endoscopic transsphenoidal approach has become the gold standard for surgical treatment of treating pituitary adenomas or other lesions in that area. Opening of bony skull base has been performed with burrs, chisels, and hammers or standard instruments like punches and circular top knives. The creation of primary bone flaps—as in external craniotomies—is difficult.The piezoelectric osteotomes used in the present study allows creating a bone flap for endoscopic transnasal approaches in certain areas. The aim of this study was to prove the feasibility of piezoelectric endoscopic transnasal craniotomies. Study Design. Cadaveric study. Methods. On cadaveric specimens (N = 5), a piezoelectric system with specially designed hardware for endonasal application was applied and endoscopic transsphenoidal craniotomies at the sellar floor, tuberculum sellae, and planum sphenoidale were performed up to a size of 3–5 cm2. Results. Bone flaps could be created without fracturing with the piezoosteotome and could be reimplanted. Endoscopic handling was unproblematic and time required was not exceeding standard procedures. Conclusion. In a cadaveric model, the piezoelectric endoscopic transsphenoidal craniotomy (PETC) is technically feasible. This technique allows the surgeon to create a bone flap in endoscopic transnasal approaches similar to existing standard transcranial craniotomies. Future trials will focus on skull base reconstruction using this bone flap. PMID:24689037

  3. Peroral endoscopic myotomy

    PubMed Central

    Kumbhari, Vivek; Khashab, Mouen A

    2015-01-01

    Peroral endoscopic myotomy (POEM) incorporates concepts of natural orifice translumenal endoscopic surgery and achieves endoscopic myotomy by utilizing a submucosal tunnel as an operating space. Although intended for the palliation of symptoms of achalasia, there is mounting data to suggest it is also efficacious in the management of spastic esophageal disorders. The technique requires an understanding of the pathophysiology of esophageal motility disorders as well as knowledge of surgical anatomy of the foregut. POEM achieves short term response in 82% to 100% of patients with minimal risk of adverse events. In addition, it appears to be effective and safe even at the extremes of age and regardless of prior therapy undertaken. Although infrequent, the ability of the endoscopist to manage an intraprocedural adverse event is critical as failure to do so could result in significant morbidity. The major late adverse event is gastroesophageal reflux which appears to occur in 20% to 46% of patients. Research is being conducted to clarify the optimal technique for POEM and a personalized approach by measuring intraprocedural esophagogastric junction distensibility appears promising. In addition to esophageal disorders, POEM is being studied in the management of gastroparesis (gastric pyloromyotomy) with initial reports demonstrating technical feasibility. Although POEM represents a paradigm shift the management of esophageal motility disorders, the results of prospective randomized controlled trials with long-term follow up are eagerly awaited. PMID:25992188

  4. [Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].

    PubMed

    Jung, Hwoon Yong

    2017-09-25

    Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.

  5. [Liver Abscess Secondary to Perforation after Duodenal Endoscopic Resection].

    PubMed

    Choi, Seung Ho; Kim, Su Jin; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Kim, Tae Un; Lee, Jeong Seok; Ko, Ji Hwan

    2018-05-25

    Duodenal perforation is a complication of endoscopic mucosal resection. Liver abscess secondary to iatrogenic perforation is extremely rare. A 43-year-old female visited the hospital to remove a sub-epithelial tumor on the duodenal bulb. After endoscopic mucosal resection with band ligation, duodenal perforation occurred. Endoscopic closure was performed successfully using a clipping device to manage duodenal perforation. After 4 weeks, the patient visited our outpatient clinic due to abdominal pain and fever. Abdominal computed tomography showed liver abscess that involved segment three. Liver abscess was resolved with a 10-week antibiotic treatment. To the best of our knowledge, no case of liver abscess secondary to duodenal perforation by endoscopic resection was reported to date in Korea. Here, we report a case of liver abscess caused by a duodenal perforation after endoscopic mucosal resection.

  6. Endoscopic Management of Peri-Pancreatic Fluid Collections.

    PubMed

    Yip, Hon Chi; Teoh, Anthony Yuen Bun

    2017-09-15

    In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.

  7. Concordance of Two Endoscopic Procedures for Diagnosis of Carcinoma of the Upper Aerodigestive Tract

    ClinicalTrials.gov

    2014-08-15

    Upper Aerodigestive Tract Lesions; Neoplasms, Oropharyngeal; Oropharyngeal Cancer; Neoplasms, Hypopharyngeal; Hypopharyngeal Cancer; Head and Neck Neoplasms; UADT Neoplasms; Carcinoma, Squamous Cell; Papilloma

  8. Endoscopic methods in the treatment of early-stage esophageal cancer

    PubMed Central

    2014-01-01

    Most patients with early esophageal cancer restricted to the mucosa may be offered endoscopic therapy, which is similarly effective, less invasive and less expensive than esophagectomy. Selection of appropriate relevant treatment and therapy methods should be performed at a specialized center with adequate facilities. The selection of an endoscopic treatment method for high-grade dysplasia and early-stage esophageal adenocarcinoma requires that tumor infiltration is restricted to the mucosa and that there is no neighboring lymph node metastasis. In squamous cell carcinoma, this treatment method is accepted in cases of tumors invading only up to the lamina propria of mucosa (m2). Tumors treated with the endoscopic method should be well or moderately differentiated and should not invade lymphatic or blood vessels. When selecting endoscopic treatments for these lesions, a combination of endoscopic resection and endoscopic ablation methods should be considered. PMID:25097676

  9. Endoscopic management of peripancreatic fluid collections.

    PubMed

    Goyal, Jatinder; Ramesh, Jayapal

    2015-07-01

    Peripancreatic fluid collections are a well-known complication of pancreatitis and can vary from fluid-filled collections to entirely necrotic collections. Although most of the fluid-filled pseudocysts tend to resolve spontaneously with conservative management, intervention is necessary in symptomatic patients. Open surgery has been the traditional treatment modality of choice though endoscopic, laparoscopic and transcutaneous techniques offer alternative drainage approaches. During the last decade, improvement in endoscopic ultrasound technology has enabled real-time access and drainage of fluid collections that were previously not amenable to blind transmural drainage. This has initiated a trend towards use of this modality for treatment of pseudocysts. In this review, we have summarised the existing evidence for endoscopic drainage of peripancreatic fluid collections from published studies.

  10. Endoscopic management of benign biliary strictures.

    PubMed

    Rustagi, Tarun; Jamidar, Priya A

    2015-01-01

    Benign biliary strictures are a common indication for endoscopic retrograde cholangiopancreatography (ERCP). Endoscopic management has evolved over the last 2 decades as the current standard of care. The most common etiologies of strictures encountered are following surgery and those related to chronic pancreatitis. High-quality cross-sectional imaging provides a road map for endoscopic management. Currently, sequential placement of multiple plastic biliary stents represents the preferred approach. There is an increasing role for the treatment of these strictures using covered metal stents, but due to conflicting reports of efficacies as well as cost and complications, this approach should only be entertained following careful consideration. Optimal management of strictures is best achieved using a team approach with the surgeon and interventional radiologist playing an important role.

  11. Endoscopic thoracic sympathectomy

    MedlinePlus

    Endoscopic thoracic sympathectomy (ETS) is surgery to treat sweating that is much heavier than normal. This condition ... hyperhidrosis . Usually the surgery is used to treat sweating in the palms or face. The sympathetic nerves ...

  12. Successful closure of chronic BPF by thoracoscopy after failure of endoscopic fibrin glue application and thoracoplasty.

    PubMed

    Tschopp, J M; Evéquoz, D; Karrer, W; Aymon, E; Naef, A P

    1990-03-01

    We report a case of chronic debilitating BPF following right upper lobe resection. Despite several endobronchial applications of fibrin glue, we could not close it. Since the patient was extremely debilitated by symptoms due to the BPF, a thoracoplasty was attempted but was not successful. Finally, the BPF was definitely closed by instillation of talc into the pleura through thoracoscopy. To our knowledge, this is the first reported case of chemical closure of a recalcitrant BPF by the route of thoracoscopy. It also shows the failure of endoscopic fibrin glue application in such a condition.

  13. Extended Endoscopic and Open Sinus Surgery for Refractory Chronic Rhinosinusitis.

    PubMed

    Eloy, Jean Anderson; Marchiano, Emily; Vázquez, Alejandro

    2017-02-01

    This review discusses extended endoscopic and open sinus surgery for refractory chronic rhinosinusitis. Extended maxillary sinus surgery including endoscopic maxillary mega-antrostomy, endoscopic modified medial maxillectomy, and inferior meatal antrostomy are described. Total/complete ethmoidectomy with mucosal stripping (nasalization) is discussed. Extended endoscopic sphenoid sinus procedures as well as their indications and potential risks are reviewed. Extended endoscopic frontal sinus procedures, such the modified Lothrop procedure, are described. Extended open sinus surgical procedures, such as the Caldwell-Luc approach, frontal sinus trephine procedure, external frontoethmoidectomy, frontal sinus osteoplastic flap with or without obliteration, and cranialization, are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Endoscopic Optical Coherence Tomography for Clinical Gastroenterology

    PubMed Central

    Tsai, Tsung-Han; Fujimoto, James G.; Mashimo, Hiroshi

    2014-01-01

    Optical coherence tomography (OCT) is a real-time optical imaging technique that is similar in principle to ultrasonography, but employs light instead of sound waves and allows depth-resolved images with near-microscopic resolution. Endoscopic OCT allows the evaluation of broad-field and subsurface areas and can be used ancillary to standard endoscopy, narrow band imaging, chromoendoscopy, magnification endoscopy, and confocal endomicroscopy. This review article will provide an overview of the clinical utility of endoscopic OCT in the gastrointestinal tract and of recent achievements using state-of-the-art endoscopic 3D-OCT imaging systems. PMID:26852678

  15. Transanal endoscopic microsurgery: a New Zealand experience.

    PubMed

    Bloomfield, Ian; Van Dalen, Roelof; Lolohea, Simione; Wu, Linus

    2018-06-01

    Transanal endoscopic microsurgery (TEMS) is a proven alternative therapy to either radical surgery or endoscopic mucosal resection for rectal neoplasms. It has proven benefits with lower morbidity and mortality compared with total mesorectal excision, and a lower local recurrence rate when compared to endoscopic mucosal techniques. A retrospective data collection of TEMS procedures performed through Waikato District Health Board, New Zealand, from 2010 to 2015 was conducted. Supportive follow-up data were sourced from patient records and from local centres around New Zealand. A total of 137 procedures were performed over the study period, with five being repeat procedures. Procedures were mostly performed for benign lesions (66.4%) with an overall complication rate of 15.3%, only five of which were Clavien-Dindo grade III (3.6%). Our local recurrence rate after resection of benign lesions was 5.1%. Our data set demonstrates the TEMS procedure to be safe compared to radical resection (total mesorectal excision) for sessile rectal lesions. Close endoscopic follow-up is recommended, especially for close or incomplete margins. Good therapeutic results can be obtained for appropriately selected early malignant lesions. TEMS provides better oncological results than endoscopic mucosal resection or transanal excision. © 2017 Royal Australasian College of Surgeons.

  16. Per-oral endoscopic myotomy (POEM) for esophageal achalasia.

    PubMed

    Pescarus, Radu; Shlomovitz, Eran; Swanstrom, Lee L

    2014-01-01

    Per-oral endoscopic myotomy (POEM) is a new minimally invasive endoscopic treatment for achalasia. Since the first modern human cases were published in 2008, around 2,000 cases have been performed worldwide. This technique requires advanced endoscopic skills and a learning curve of at least 20 cases. POEM is highly successful with over 90 % improvement in dysphagia while offering patients the advantage of a low impact endoscopic access. The main long-term complication is gastroesophageal reflux (GER) with an estimated incidence of 35 %, similar to the incidence of GER post-laparoscopic Heller with fundoplication. Although POEM represents a paradigm shift in the treatment of achalasia, more long-term data are clearly needed to further define its role in the treatment algorithm of this rare disease.

  17. Endoscopic management and outcomes of pregnant women hospitalized for nonvariceal upper GI bleeding: a nationwide analysis.

    PubMed

    Nguyen, Geoffrey C; Dinani, Amreen M; Pivovarov, Kevin

    2010-11-01

    Upper GI endoscopy has an important diagnostic and therapeutic role in the management of nonvariceal upper GI bleeding (NVUGB). To characterize nationwide patterns of utilization of upper GI endoscopy in pregnant women with NVUGB and to assess health outcomes. Retrospective cohort study. Participating hospitals from the Nationwide Inpatient Sample, 1998-2007. Pregnant and age-matched nonpregnant women admitted for NVUGB. The study population was classified as pregnant women with NVUGB (n = 1210) and nonpregnant women with NVUGB (n = 6050). Rate of upper GI endoscopy, maternal mortality, fetal death/complications, and premature delivery. Pregnant women were less likely than nonpregnant women to undergo upper GI endoscopy (26% vs 69%; P < .0001) even after adjustment for comorbidities, transfusion requirement, and the presence of hypovolemic shock (adjusted odds ratio, 0.19; 95% confidence interval, 0.16-0.22). Among those who underwent endoscopy, pregnant women were less likely to undergo the procedure within 24 hours of admission (50% vs 57%; P = .02). Mortality was lower among pregnant women compared with nonpregnant women (0% vs 0.6%; P = .006). In comparing outcomes between those who did and did not undergo endoscopy, there was no difference in fetal loss (0.2% vs 0.6%), fetal distress/complications (2.7% vs 2.6%), or premature delivery (7.3% vs 6.4%). The study was based on administrative data. A conservative nonendoscopic approach is common in the management of pregnant women with NVUGB and is not associated with worse maternal or fetal outcomes. Upper GI endoscopy is, however, safe when judiciously implemented in the actively bleeding patient. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  18. Confocal laser endomicroscopy and ultrasound endoscopy during the same endoscopic session for diagnosis and staging of gastric neoplastic lesions.

    PubMed

    Gheorghe, C; Iacob, R; Dumbrava, Mona; Becheanu, G; Ionescu, M

    2009-01-01

    Confocal LASER endomicroscopy (CLE) is a newly developed endoscopic technique which allows subsurface in vivo histological assessment during ongoing endoscopy and targeted biopsies. Ultrasound endoscopy (EUS) is a useful tool in staging upper GI malignant lesions. We describe for the first time the use of both techniques during the same endoscopic session, in a pilot study, in order to increase the diagnostic yield of histological assessment and provide the staging of the gastric neoplastic lesions thus decreasing the time to therapeutic decision. CLE has been performed with the Pentax EG-3870CIK confocal endomicroscope after a 5 ml intravenous 10% fluorescein injection; EUS has been performed subsequently, during the same endoscopic Propofol sedation session, using a standard radial EUS-scope. Eleven patients have been investigated, 4 females, 7 males, mean age 59.7 +/- 12.3 years. The indication of CLE/EUS exploration was the presence of a gastric polypoid lesion in 37% of cases, atypical gastric ulcer in 27% of patients, gastric lymphoma 18%, suspicion of gastric cancer recurrence after resection 9% and infiltrating type gastric cancer 9%. Histological assessment after targeted biopsy has established the diagnosis of gastric adenocarcinoma in 55% of cases, gastric lymphoma in 18% of cases, gastric adenoma, gastric GIST and gastric foveolar hyperplasia in 9% of cases respectively. CLE has allowed targeted biopsies in 81.8% of cases. In 2 patients - one case with suspected recurrent gastric cancer after surgery and one case of gastric lymphoma, CLE has indicated normal gastric mucosa. The EUS evaluation has shown TO lesion in two cases, T1 in 3 cases, T2 in 3 cases, T3 in one case. The EUS evaluation showed in one gastric lymphoma patient a lesion interesting the mucosa and submucosa with regional adenopathy and a submucosal lesion with regional adenopathy in the other gastric lymphoma case. The therapeutic decision was surgery in 73% of cases, chemotherapy and

  19. The proposal of the locomotive system for capsule endoscopes.

    PubMed

    Watada, Masaya; Ozawa, Ken-ichi

    2008-01-01

    The capsule endoscope authorized in some countries in late years has the advantage of preparing the observation in difficult small intestines in a past endoscope. However, because the promotion mechanism of a capsule endoscope depends only on the peristaltic motion of a digestive organ, the oversight of change to a morbid state is feared. Authors aim at the achievement of a free movement and remote diagnoses in small intestines, and are developing a locomotive system for capsule endoscopes. This paper describes the proposal of the locomotive system with an electromagnetic actuator, and examination of a simulation model for this locomotive system.

  20. New developments in endoscopic treatment of chronic pancreatitis.

    PubMed

    Didden, P; Bruno, M; Poley, J W

    2012-12-01

    The aim of endoscopic therapy of chronic pancreatitis (CP) is to treat pain by draining the pancreatic duct or managing loco-regional complications. Recent decennia were characterized by continuous improvement of endoscopic techniques and devices, resulting in a better clinical outcome. Novel developments now also provide the opportunity to endoscopically treat refractory CP-related complications. Especially suboptimal surgical candidates could potentially benefit from these new developments, consequently avoiding invasive surgery. The use of fully covered self-expandable metal stents (SEMS) has been explored in pancreatic and CP-related biliary duct strictures, resistant to conventional treatment with plastic endoprotheses. Furthermore, endosonography-guided transmural drainage of the main pancreatic duct via duct-gastrostomy is an alternative treatment option in selected cases. Pancreatic pseudocysts represent an excellent indication for endoscopic therapy with some recent case series demonstrating effective drainage with the use of a fully covered SEMS. Although results of these new endoscopic developments are promising, high quality randomized trials are required to determine their definite role in the management of chronic pancreatitis.

  1. Motion magnification for endoscopic surgery

    NASA Astrophysics Data System (ADS)

    McLeod, A. Jonathan; Baxter, John S. H.; de Ribaupierre, Sandrine; Peters, Terry M.

    2014-03-01

    Endoscopic and laparoscopic surgeries are used for many minimally invasive procedures but limit the visual and haptic feedback available to the surgeon. This can make vessel sparing procedures particularly challenging to perform. Previous approaches have focused on hardware intensive intraoperative imaging or augmented reality systems that are difficult to integrate into the operating room. This paper presents a simple approach in which motion is visually enhanced in the endoscopic video to reveal pulsating arteries. This is accomplished by amplifying subtle, periodic changes in intensity coinciding with the patient's pulse. This method is then applied to two procedures to illustrate its potential. The first, endoscopic third ventriculostomy, is a neurosurgical procedure where the floor of the third ventricle must be fenestrated without injury to the basilar artery. The second, nerve-sparing robotic prostatectomy, involves removing the prostate while limiting damage to the neurovascular bundles. In both procedures, motion magnification can enhance subtle pulsation in these structures to aid in identifying and avoiding them.

  2. Correlation of radiographic and endoscopic evaluation of gastrojejunal anastomosis after Roux-en-Y gastric bypass.

    PubMed

    Szomstein, Samuel; Kaidar-Person, Orit; Naberezny, Kristoff; Cruz-Correa, Marcia; Rosenthal, Raul

    2006-01-01

    Anastomotic stenosis presents as one of the most common late complications in the postoperative period after bariatric surgery. It is often diagnosed by upper gastrointestinal series (UGIS) and/or upper endoscopy (UE). The aim of this study was to determine whether a correlation exists between the Gastrografin UGIS and UE findings in the determination of gastrojejunal anastomotic strictures after Roux-en-Y gastric bypass (RYGB). Between July 2001 and October 2003, all medical records of patients who underwent RYGB at our institution were retrospectively reviewed. The medical records of patients who underwent UE because of symptoms suggestive of gastric outlet obstruction and those of patients who were initially evaluated by Gastrografin UGIS before UE were evaluated further. Of 535 morbidly obese patients who underwent RYGB, 52 (9.7%) had UE and were included in this study. The mean number of UEs performed per patient was 2.67. Of these 52 patients, 30 underwent Gastrografin UGIS before UE. The mean diameter of the anastomosis on the first UE was 5.97 mm and on Gastrografin UGIS was 6.83 mm. A good correlation was found between the Gastrografin UGIS and UE findings using Pearson's correlation coefficient (0.44, P = .02) and single linear regression analysis using the endoscopic diameter as the outcome and radiographic findings as the predictor (beta = 0.27, P = .025, 95% confidence interval 0.30-0.49). In our study, the Gastrografin UGIS findings correlated positively with the endoscopic gastrojejunal anastomosis findings in patients with anastomotic stricture who had undergone RYGB.

  3. Upper Gastrointestinal Bleeding in Chinese Children: A Multicenter 10-Year Retrospective Study.

    PubMed

    Yu, Yi; Wang, Baoxiang; Yuan, Lan; Yang, Hui; Wang, Xinqiong; Xiao, Yuan; Mei, Hong; Xu, Chundi

    2016-08-01

    Objective This study aims to analyze the clinical and endoscopic presentations of upper gastrointestinal bleeding (UGIB) in the Chinese children. Methods A 10-year retrospective study was made on children with UGIB and undertaken esophagogastroduodenoscopy (EGD) from 4 tertiary referral centers in China. Results Of the 1218 children studied, the bleeding source was found in 76.4%. Erosive gastritis was the most common endoscopic finding (33.5%), followed by duodenal ulcer (23.2%). The proportion of erosive gastritis decreased with age (correlation coefficient = -0.787), and duodenal ulcer increased with age (correlation coefficient = 0.958). The bleeding source was more likely to be determined in children having EGDs within 48 hours (80.6% vs 67.9%). Conclusions In Chinese children with UGIB, erosive gastritis and duodenal ulcer were the leading causes, and their proportions varied with age. EGDs performed within 48 hours may improve the possibility of finding the source of bleeding. © The Author(s) 2015.

  4. Surgical management of failed endoscopic treatment of pancreatic disease.

    PubMed

    Evans, Kimberly A; Clark, Colby W; Vogel, Stephen B; Behrns, Kevin E

    2008-11-01

    Endoscopic therapy of acute and chronic pancreatitis has decreased the need for operative intervention. However, a significant proportion of patients treated endoscopically require definitive surgical management for persistent symptoms. Our aim was to determine which patients are likely to fail with endoscopic therapy, and to assess the clinical outcome of surgical management. Patients were identified using ICD-9 codes for pancreatic disease as well as CPT codes for endoscopic therapy followed by surgery. Patients with documented acute or chronic pancreatitis treated endoscopically prior to surgical therapy were included (N = 88). The majority of patients (65%) exhibited chronic pancreatitis due to alcohol abuse. Common indicators for surgery were: persistent symptoms, anatomy not amenable to endoscopic treatment and unresolved common bile duct or pancreatic duct strictures. Surgical salvage procedures included internal drainage of a pseudocyst or an obstructed pancreatic duct (46%), debridement of peripancreatic fluid collections (25%), and pancreatic resection (31%). Death occurred in 3% of patients. The most common complications were hemorrhage (16%), wound infection (13%), and pulmonary complications (11%). Chronic pancreatitis with persistent symptoms is the most common reason for pancreatic surgery following endoscopic therapy. Surgical salvage therapy can largely be accomplished by drainage procedures, but pancreatic resection is common. These complex procedures can be performed with acceptable mortality but also with significant risk for morbidity.

  5. Endoscopic transgastric drainage of a gastric wall abscess after endoscopic submucosal dissection

    PubMed Central

    Dohi, Osamu; Dohi, Moyu; Inoue, Ken; Gen, Yasuyuki; Jo, Masayasu; Tokita, Kazuhiko

    2014-01-01

    A 63-year-old woman was referred to our hospital for further examination because of an incidental finding of early gastric cancer. Endoscopic submucosal dissection (ESD) was successfully performed for complete resection of the tumor. On the first post-ESD day, the patient suddenly complained of abdominal pain after an episode of vomiting. Abdominal computed tomography (CT) showed delayed perforation after ESD. The patient was conservatively treated with an intravenous proton pump inhibitor and antibiotics. On the fifth post-ESD day, CT revealed a gastric wall abscess in the gastric body. Gastroscopy revealed a gastric fistula at the edge of the post-ESD ulcer, and pus was found flowing into the stomach. An intradrainage stent and an extradrainage nasocystic catheter were successfully inserted into the abscess for endoscopic transgastric drainage. After the procedure, the clinical symptoms and laboratory test results improved quickly. Two months later, a follow-up CT scan showed no collection of pus. Consequently, the intradrainage stent was removed. Although the gastric wall abscess recurred 2 wk after stent removal, it recovered soon after endoscopic transgastric drainage. Finally, after stent removal and oral antibiotic treatment for 1 mo, no recurrence of the gastric wall abscess was found. PMID:24574787

  6. Calibration procedures of the Tore-Supra infrared endoscopes

    NASA Astrophysics Data System (ADS)

    Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.

    2018-01-01

    Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.

  7. Use of prototype two-channel endoscope with elevator enables larger lift-and-snare endoscopic mucosal resection in a porcine model

    PubMed Central

    Atkinson, Matthew; Chukwumah, Chike; Marks, Jeffrey; Chak, Amitabh

    2014-01-01

    Background: Flat and depressed lesions are becoming increasingly recognized in the esophagus, stomach, and colon. Various techniques have been described for endoscopic mucosal resection (EMR) of these lesions. Aims: To evaluate the efficacy of lift-grasp-cut EMR using a prototype dual-channel forward-viewing endoscope with an instrument elevator in one accessory channel (dual-channel elevator scope) as compared to standard dual-channel endoscopes. Methods: EMR was performed using a lift-grasp-cut technique on normal flat rectosigmoid or gastric mucosa in live porcine models after submucosal injection of 4 mL of saline using a dual-channel elevator scope or a standard dual-channel endoscope. With the dual-channel elevator scope, the elevator was used to attain further lifting of the mucosa. The primary endpoint was size of the EMR specimen and the secondary endpoint was number of complications. Results: Twelve experiments were performed (six gastric and six colonic). Mean specimen diameter was 2.27 cm with the dual-channel elevator scope and 1.34 cm with the dual-channel endoscope (P = 0.018). Two colonic perforations occurred with the dual-channel endoscope, vs no complications with the dual-channel elevator scope. Conclusions: The increased lift of the mucosal epithelium, through use of the dual-channel elevator scope, allows for larger EMR when using a lift-grasp-cut technique. Noting the thin nature of the porcine colonic wall, use of the elevator may also make this technique safer. PMID:24760237

  8. Valuing innovative endoscopic techniques: per-oral endoscopic myotomy for the management of achalasia.

    PubMed

    Shah, Eric D; Chang, Andrew C; Law, Ryan

    2018-04-20

    Unclear reimbursement for new and innovative endoscopic procedures can limit adoption in clinical practice despite effectiveness in clinical trials. The aim of this study was to determine maximum cost-effective reimbursement for per-oral endoscopic myotomy (POEM) in treating achalasia. We constructed a decision analytic model assessing POEM versus laparoscopic Heller myotomy with Dor fundoplication (LHM) in managing achalasia from a payer perspective over a 1-year time horizon. Reimbursement data were derived from 2017 Medicare data. Responder rates were based on clinically meaningful improvement in validated Eckardt scores. Validated health utility values were assigned to terminal health states based on data previously derived with a standard gamble technique. Contemporary willingness-to-pay (WTP) levels per quality-adjusted life year (QALY) were used to estimate maximum reimbursement for POEM using threshold analysis. Effectiveness of POEM and LHM was similar at one year of follow-up (0.91 QALY). Maximum cost-effective reimbursement for POEM was $1,200.07 to $1,389.85 (33.4-38.7 total 2017 RVUs). This compares to contemporary total reimbursement of 10-15 total RVU for advanced endoscopic procedures. The model was most sensitive to the probability of GERD after procedure. The rate of conversion to open laparotomy due to perforation or bleeding was infrequent in published clinical practice experience, thus did not significantly affect reimbursement. POEM is an example of an innovative and potentially disruptive endoscopic technique offering greater cost-effective value and similar outcomes to the established surgical standard at contemporary reimbursement levels. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. Long-term mortality and causes of death in endoscopically verified upper gastrointestinal bleeding: comparison of bleeding patients and population controls.

    PubMed

    Miilunpohja, S; Jyrkkä, J; Kärkkäinen, J M; Kastarinen, H; Heikkinen, M; Paajanen, H; Rantanen, T; Hartikainen, Jek

    2017-11-01

    Upper gastrointestinal bleeding (UGIB) is a common emergency, with in-hospital mortality between 3 and 14%. However, the long-term mortality and causes of death are unknown. We investigated the long-term mortality and causes of death in UGIB patients in a retrospective single-centre case-control study design. A total of 569 consecutive patients, aged ≥18 years, admitted to Kuopio University Hospital for their first endoscopically verified UGIB during the years 2009-2011 were identified from hospital records. For each UGIB patient, an age, sex and hospital district matched control patient was identified from the Statistics Finland database. Data on endoscopy procedures, laboratory values, comorbidities and medication were obtained from patient records. Data on deaths and causes of death were obtained from Statistics Finland. In-hospital mortality of UGIB patients was low at 3.3%. The long-term (mean follow-up 32 months) mortality of UGIB patients was significantly higher than controls (34.1 versus 12.1%, p < .001). During the 6 months following UGIB, the risk of death compared to controls was highest (HR 19.2, 95% CI 7.0-52.4, p < .001) and remained higher up to 3 years after the bleeding. Beyond 3 years' follow-up, there was no difference in mortality between the groups (HR 0.7, 95% CI 0.4-1.6, p = .436). During the first 3 months after the UGIB episode, mortality was related to gastrointestinal diseases; after 3 months, the causes of death were related to comorbidities and did not differ from causes of death in controls. UGIB patients have three times higher long-term mortality than population controls.

  10. Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.

    PubMed

    Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya

    2017-02-01

    Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.

  11. Endoscopic brow lifts uber alles.

    PubMed

    Patel, Bhupendra C K

    2006-12-01

    Innumerable approaches to the ptotic brow and forehead have been described in the past. Over the last twenty-five years, we have used all these techniques in cosmetic and reconstructive patients. We have used the endoscopic brow lift technique since 1995. While no one technique is applicable to all patients, the endoscopic brow lift, with appropriate modifications for individual patients, can be used effectively for most patients with brow ptosis. We present the nuances of this technique and show several different fixation methods we have found useful.

  12. Emergency arterial embolization of upper gastrointestinal and jejunal tumors: An analysis of 12 patients with severe bleeding.

    PubMed

    Zandrino, F; Tettoni, S M; Gallesio, I; Summa, M

    2017-01-01

    The goal of this study was to retrospectively assess the efficacy of emergency percutaneous transcatheter arterial embolization in patients with severe bleeding due to upper gastrointestinal or jejunal tumor. Twelve patients (7 men, 5 women; mean age, 74 years±14 (SD); range: 54-86 years) with severe bleeding from the upper gastrointestinal tract, with failed endoscopic treatment not eligible for emergency surgery were treated by emergency percutaneous transcatheter arterial embolization. The bleeding cause was gastric tumor in 7 patients, duodenal tumor in 4 patients and jejunal tumor in one patient. Procedure details and follow-up were reviewed. Twelve embolization procedures were performed using various embolic agents. Embolization was achieved and bleeding was stopped in all patients. Five patients underwent surgery within the 30 days following embolization. In the remaining 7 patients, no bleeding occurred at 1 month follow-up in 6 patients and bleeding recurred in one patient at 1 month. In this later patient, endoscopic treatment was successful. The results of our study suggest that transcatheter arterial embolization is safe and effective in patients with severe arterial bleeding due to upper gastrointestinal or jejunal tumor. In some patients, transcatheter arterial embolization can be used as a bridge to surgery. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. High-level disinfection of gastrointestinal endoscope reprocessing

    PubMed Central

    Chiu, King-Wah; Lu, Lung-Sheng; Chiou, Shue-Shian

    2015-01-01

    High level disinfection (HLD) of the gastrointestinal (GI) endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition, GI endoscopy is a semicritical medical device. Hence, such medical devices require major quality assurance for disinfection. And because many of these items are temperature sensitive, low-temperature chemical methods, such as liquid chemical germicide, must be used rather than steam sterilization. In summarizing guidelines for infection prevention and control for GI endoscopy, there are three important steps that must be highlighted: manual washing, HLD with automated endoscope reprocessor, and drying. Strict adherence to current guidelines is required because compared to any other medical device, the GI endoscope is associated with more outbreaks linked to inadequate cleaning or disinfecting during HLD. Both experimental evaluation on the surveillance bacterial cultures and in-use clinical results have shown that, the monitoring of the stringent processes to prevent and control infection is an essential component of the broader strategy to ensure the delivery of safe endoscopy services, because endoscope reprocessing is a multistep procedure involving numerous factors that can interfere with its efficacy. Based on our years of experience in the surveillance of culture monitoring of endoscopic reprocessing, we aim in this study to carefully describe what details require attention in the GI endoscopy disinfection and to share our experience so that patients can be provided with high quality and safe medical practices. Quality management encompasses all aspects of pre- and post-procedural care including the efficiency of the endoscopy unit and reprocessing area, as well as the endoscopic procedure itself. PMID:25699232

  14. Accuracy of the initial endoscopic diagnosis in the discrimination of gastric ulcers: is endoscopic follow-up study always needed?

    PubMed

    Bustamante, Marco; Devesa, Francesc; Borghol, Abdul; Ortuño, Juan; Ferrando, Maria Jose

    2002-07-01

    Endoscopic follow-up study of gastric ulcers has been recommended routinely because of the possibility that a gastric neoplasm will be missed in the initial endoscopy. Some authors, most of them reporting data from areas of low gastric carcinoma incidence, have questioned this policy because of the low numbers of curable cancers detected and the high cost of such a program. To assess the accuracy of endoscopy diagnosis of gastric ulcers, and to evaluate the efficacy and cost of a gastric ulcer follow-up endoscopic program in an area with an intermediate incidence rate of gastric cancer. A retrospective study was used to identify all the gastroscopies in which a gastric ulcer had been diagnosed during a 6-year period. The endoscopic impression was compared with the histologic diagnosis, sensitivity, specificity, positive and negative predictive values, and the likelihood ratio. Patients who completed a follow-up program also were reviewed. For each neoplasm discovered, the number of endoscopies and global cost were calculated. In the 741 gastroscopies performed, 547 gastric ulcers were diagnosed in 529 patients. Biopsies were taken in 330 patients, in whom 341 gastric ulcers were found. At the index endoscopy, 41 gastric neoplasms (12.4%) were diagnosed. The accuracy of endoscopic malignancy diagnosis was as follows: positive predictive value of 0.68, negative predictive value of 0.98, sensitivity of 0.82, and specificity of 0.95. The likelihood ratio was 16. A total of 117 patients completed the follow-up program. Three new cases of gastric cancer (2.6%) were identified. In these three cases, the initial opinion of the endoscopist was uncertain. In the authors' experience, the cost of each gastric cancer diagnosed has been $4.653 (U.S. dollars). The endoscopic impression correlates with the histologic diagnosis even in a area of intermediate gastric cancer incidence. Endoscopic follow-up study may be restricted to cases of uncertain or malignant endoscopic

  15. Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.

    PubMed

    Meier, Benjamin; Caca, Karel

    2016-12-01

    Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.

  16. A research agenda for the European Association for Endoscopic Surgeons (EAES).

    PubMed

    Francis, Nader; Kazaryan, Airazat M; Pietrabissa, Andrea; Goitein, David; Yiannakopoulou, Eugenia; Agresta, Ferdinando; Khatkov, Igor; Schulze, Svend; Arulampalam, Tan; Tomulescu, Victor; Kim, Young-Woo; Targarona, Eduardo Mª; Zaninotto, Giovanni

    2017-05-01

    The European Association of Endoscopic Surgeons (EAES) conducted this study aiming to identify the top research questions which are relevant to surgeons in Minimal Access Surgery (MAS). This is in order to promote and link research questions to the current clinical practice in MAS in Europe. Using a systematic methodology, (modified Delphi), the EAES members and leadership teams were surveyed to obtain consensus on the top research priorities in MAS. The responses were categorized and redistributed to the membership to rate the level of importance of each research question. The data were reported as the weighted average score with a scale from 1 (lowest agreement) to 5 (highest agreement). In total, 324 of 2580 (12.5%) of the EAES members and the leaders responded to the survey and contributed to the final consensus. The ranked responses over the 80th percentile identified 39 research priorities with rating ranged from 4.22 to 3.67. The top five highest ranking research priorities in the EAES were centered on improving training in MAS, laparoscopic surgery for benign upper gastrointestinal conditions, integration of novel technology in OR, translational and basic science research in bariatric surgery and investigating the role of MAS in rectal cancer. An EAES research agenda was developed using a systematic methodology and can be used to focus MAS research. This study was commissioned by the European Association for Endoscopic Surgery (EAES).

  17. Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.

    PubMed

    Ecker, J; Perera, N; Ebert, J

    2015-02-01

    Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.

  18. Endoscopic laser-urethroplasty

    NASA Astrophysics Data System (ADS)

    Gilbert, Peter

    2006-02-01

    The objective was to prove the advantage of endoscopic laser-urethroplasty over internal urethrotomy in acquired urethral strictures. Patients and Method: From January, 1996 to June, 2005, 35 patients with a mean age of 66 years were submitted to endoscopic laser-urethroplasty for strictures of either the bulbar (30) or membranous (5) urethra. The operations were carried out under general anesthesia. First of all, the strictures were incised at the 4, 8 and 12 o'clock position by means of a Sachse-urethrotom. Then the scar flap between the 4 and 8 o'clock position was vaporized using a Nd:YAG laser, wavelength 1060 nm and a 600 pm bare fiber, the latter always being in contact with the tissue. The laser worked at 40W power in continuous mode. The total energy averaged 2574 J. An indwelling catheter was kept in place overnight and the patients were discharged the following day. Urinalysis, uroflowmetry and clinical examination were performed at two months after surgery and from then on every six months. Results: No serious complications were encountered. Considering a mean follow-up of 18 months, the average peak flow improved from 7.3 ml/s preoperatively to 18.7 mVs postoperatively. The treatment faded in 5 patients ( 14.3% ) who finally underwent open urethroplasty. Conclusions: Endoscopic laser-urethroplasty yields better short-term results than internal visual urethrotomy. Long-term follow-up has yet to confirm its superiority in the treatment of acquired urethral strictures.

  19. The Pedicled Buccal Fat Pad: Anatomical Study of the New Flap for Skull Base Defect Reconstruction After Endoscopic Endonasal Transpterygoid Surgery

    PubMed Central

    Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.

    2016-01-01

    Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047

  20. Endoscopic surgery of the nose and paranasal sinus.

    PubMed

    Palmer, Orville; Moche, Jason A; Matthews, Stanley

    2012-05-01

    Mucosal preservation is of paramount importance in the diagnosis and surgical management of the sinonasal tract. The endoscope revolutionized the practice of endoscopic nasal surgery. As a result, external sinus surgery is performed less frequently today, and more emphasis is placed on functional endoscopy and preservation of normal anatomy. Endoscopic surgery of the nose and paranasal sinus has provided improved surgical outcomes and has shortened the length of stay in hospital. It has also become a valuable teaching tool. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Robust feature tracking for endoscopic pose estimation and structure recovery

    NASA Astrophysics Data System (ADS)

    Speidel, S.; Krappe, S.; Röhl, S.; Bodenstedt, S.; Müller-Stich, B.; Dillmann, R.

    2013-03-01

    Minimally invasive surgery is a highly complex medical discipline with several difficulties for the surgeon. To alleviate these difficulties, augmented reality can be used for intraoperative assistance. For visualization, the endoscope pose must be known which can be acquired with a SLAM (Simultaneous Localization and Mapping) approach using the endoscopic images. In this paper we focus on feature tracking for SLAM in minimally invasive surgery. Robust feature tracking and minimization of false correspondences is crucial for localizing the endoscope. As sensory input we use a stereo endoscope and evaluate different feature types in a developed SLAM framework. The accuracy of the endoscope pose estimation is validated with synthetic and ex vivo data. Furthermore we test the approach with in vivo image sequences from da Vinci interventions.

  2. Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.

    PubMed

    Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter

    2017-01-01

    Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.

  3. Do patients with iron deficiency without anemia benefit from an endoscopic examination?

    PubMed

    García García de Paredes, Ana; Teruel Sánchez-Vegazo, Carlos; Hernanz Ruiz, Nerea; Ferre Aracil, Carlos; Rodríguez de Santiago, Enrique; Aguilera Castro, Lara; Sierra Morales, María; Albillos, Agustín

    2017-07-01

    The need for endoscopic investigation in patients with iron deficiency without anemia (ID) is not established. Data from patients with ID (serum ferritin ≤20 ng/mL, normal hemoglobin) studied with upper and lower endoscopies were retrospectively analyzed. Patients evaluated for iron deficiency anemia (IDA) served as controls, matched by sex and age in the proportion of 2:1. The groups were compared for the presence, type, location and age distribution of endoscopic findings. Altogether 109 patients (55% women; mean age 59.6 ± 13.5 years; aged <50 years [27.5%]; 50-69 years [43.1%]; ≥70 years [29.4%]) were included in the ID group and 218 matched controls in the IDA group. Lesions were found in a similar proportion of patients (53.2% in the ID group vs 49.1% in the IDA group, P = 0.48) irrespective of age (P = 0.92). The colonoscopy diagnostic yield was low in both the ID and IDA subgroups of aged <50 years (6.3% vs 4.2%, P = 0.76). Multivariate analysis revealed a significant relationship between age (odds ratio [OR] 1.04, 95% confidence interval [CI] 1.02-1.06) and male sex (OR 2.28, 95% CI 1.18-4.39) with a positive colonoscopy. Malignancy was significantly less frequent in the ID group (1.8% vs 14.2%, P < 0.05). The prevalence of gastrointestinal lesions in patients with and without anemia was similar but malignancy was eight times less frequent in the ID group. Systematic endoscopic evaluation in patients with ID is therefore questionable. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  4. Endoscopic Spatulation of the Intramural Ureter: A Technique to Prevent Stenosis of the Ureterovesical Junction in Patients Undergoing Resection of the Ureteral Orifice.

    PubMed

    Creta, Massimiliano; Mirone, Vincenzo; Di Meo, Sergio; Buonopane, Roberto; Fusco, Ferdinando; Imperatore, Vittorio

    2016-08-01

    Wide resection of the ureteral orifice (UO) may result in scarring and stenosis of the ureterovesical junction (UVJ). We aimed to describe a technique of endoscopic spatulation of the intramural ureter in patients undergoing resection of the UO at the time of transurethral resection of bladder tumor (TURBT) and compare the surgical and oncological outcomes of this procedure with those of patients undergoing conventional UO resection. The clinical records of patients who underwent TURBT at a single institution were retrospectively analyzed. Patients who underwent conventional UO resection or UO resection followed by endoscopic spatulation of the intramural ureter were included in the analysis. The two groups were compared in terms of intra- and postoperative outcomes. A total of 227 patients were included in the final comparative analyses. Of them, 104 underwent conventional UO resection and 123 underwent UO resection followed by endoscopic spatulation of the intramural ureter. The two groups were comparable for demographic and clinical features. There were not statistically significant differences in terms of mean operative times. The incidence of transient postoperative hydronephrosis as well as UVJ scarring and stenosis was significantly lower in patients undergoing endoscopic spatulation of the intramural ureter. The two groups were similar in terms of incidence of vesicoureteral reflux (VUR) and upper urinary tract cancer recurrence. Endoscopic spatulation of the intramural ureter after UO resection is a safe and quick procedure that significantly reduces the incidence of transient early postoperative hydronephrosis and late UVJ stricture if compared with UO resection alone. This procedure is quick to perform, safe, and does not increase the risk of VUR.

  5. Improving the Endoscopic Detection Rate in Patients with Early Gastric Cancer

    PubMed Central

    2015-01-01

    Endoscopists should ideally possess both sufficient knowledge of the endoscopic gastrointestinal disease findings and an appropriate attitude. Before performing endoscopy, the endoscopist must identify several risk factors of gastric cancer, including the patient's age, comorbidities, and drug history, a family history of gastric cancer, previous endoscopic findings of atrophic gastritis or intestinal metaplasia, and a history of previous endoscopic treatments. During endoscopic examination, the macroscopic appearance is very important for the diagnosis of early gastric cancer; therefore, the endoscopist should have a consistent and organized endoscope processing technique and the ability to comprehensively investigate the entire stomach, even blind spots. PMID:26240801

  6. Extraction of endoscopic images for biomedical figure classification

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; You, Daekeun; Chachra, Suchet; Antani, Sameer; Long, L. R.; Demner-Fushman, Dina; Thoma, George R.

    2015-03-01

    Modality filtering is an important feature in biomedical image searching systems and may significantly improve the retrieval performance of the system. This paper presents a new method for extracting endoscopic image figures from photograph images in biomedical literature, which are found to have highly diverse content and large variability in appearance. Our proposed method consists of three main stages: tissue image extraction, endoscopic image candidate extraction, and ophthalmic image filtering. For tissue image extraction we use image patch level clustering and MRF relabeling to detect images containing skin/tissue regions. Next, we find candidate endoscopic images by exploiting the round shape characteristics that commonly appear in these images. However, this step needs to compensate for images where endoscopic regions are not entirely round. In the third step we filter out the ophthalmic images which have shape characteristics very similar to the endoscopic images. We do this by using text information, specifically, anatomy terms, extracted from the figure caption. We tested and evaluated our method on a dataset of 115,370 photograph figures, and achieved promising precision and recall rates of 87% and 84%, respectively.

  7. Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.

    PubMed

    Ye, L; Zhou, X; Li, J; Jin, J

    2011-09-01

    Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p < 0.001). Mean intra-operative blood loss was 121 and 420 ml, respectively (t = 28.944, p < 0.001), a significant difference. Both techniques achieved complete tumour resection with minimal damage to adjacent tissues, and no recurrence in any patient. Coblation successfully achieves transnasal endoscopic resection of juvenile nasopharyngeal angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.

  8. Endoscopic sleeve gastroplasty: the learning curve.

    PubMed

    Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek

    2017-09-01

    Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program.  Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate.  Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P  = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P  < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P  < 0.001).  Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.

  9. Endoscopic management of chronic radiation proctitis

    PubMed Central

    Rustagi, Tarun; Mashimo, Hiroshi

    2011-01-01

    Chronic radiation proctopathy occurs in 5%-20% of patients following pelvic radiotherapy. Although many cases resolve spontaneously, some lead to chronic symptoms including diarrhea, tenesmus, urgency and persistent rectal bleeding with iron deficiency anemia requiring blood transfusions. Treatments for chronic radiation proctitis remain unsatisfactory and the basis of evidence for various therapies is generally insufficient. There are very few controlled or prospective trials, and comparisons between therapies are limited because of different evaluation methods. Medical treatments, including formalin, topical sucralfate, 5-amino salicylic acid enemas, and short chain fatty acids have been used with limited success. Surgical management is associated with high morbidity and mortality. Endoscopic therapy using modalities such as the heater probe, neodymium:yttrium-aluminium-garnet laser, potassium titanyl phosphate laser and bipolar electrocoagulation has been reported to be of some benefit, but with frequent complications. Argon plasma coagulation is touted to be the preferred endoscopic therapy due to its efficacy and safety profile. Newer methods of endoscopic ablation such as radiofrequency ablation and cryotherapy have been recently described which may afford broader areas of treatment per application, with lower rate of complications. This review will focus on endoscopic ablation therapies, including such newer modalities, for chronic radiation proctitis. PMID:22147960

  10. Endoscopic management of chronic radiation proctitis.

    PubMed

    Rustagi, Tarun; Mashimo, Hiroshi

    2011-11-07

    Chronic radiation proctopathy occurs in 5%-20% of patients following pelvic radiotherapy. Although many cases resolve spontaneously, some lead to chronic symptoms including diarrhea, tenesmus, urgency and persistent rectal bleeding with iron deficiency anemia requiring blood transfusions. Treatments for chronic radiation proctitis remain unsatisfactory and the basis of evidence for various therapies is generally insufficient. There are very few controlled or prospective trials, and comparisons between therapies are limited because of different evaluation methods. Medical treatments, including formalin, topical sucralfate, 5-amino salicylic acid enemas, and short chain fatty acids have been used with limited success. Surgical management is associated with high morbidity and mortality. Endoscopic therapy using modalities such as the heater probe, neodymium:yttrium-aluminium-garnet laser, potassium titanyl phosphate laser and bipolar electrocoagulation has been reported to be of some benefit, but with frequent complications. Argon plasma coagulation is touted to be the preferred endoscopic therapy due to its efficacy and safety profile. Newer methods of endoscopic ablation such as radiofrequency ablation and cryotherapy have been recently described which may afford broader areas of treatment per application, with lower rate of complications. This review will focus on endoscopic ablation therapies, including such newer modalities, for chronic radiation proctitis.

  11. Is side-viewing endoscope assisted balloon dilatation better for corrosive gastric outlet obstruction?

    PubMed

    Katiyar, Prashant; Nijhawan, Sandeep; Saradava, Vimal; Nagaich, Neeraj; Gupta, Gaurav; Mathur, Amit; Nepalia, Subhash

    2013-11-01

    Endoscopic balloon dilatation (EBD) is an effective therapy for caustic-induced gastric outlet obstruction (GOO). Gaining access to the stricture site is the most important step. It is sometimes difficult to negotiate a balloon through the stricture with a front-viewing endoscope due to deformed anatomy of stomach. To overcome this technical difficulty, a side-viewing endoscope can be used. There is limited data regarding the use of side-viewing endoscopes in EBD. We here report on the short-term efficacy and safety of EBD in caustic-induced GOO. In technically difficult cases, a side-viewing endoscope was used for EBD and its efficacy and safety were assessed. The study included 25 patients with caustic-induced GOO. Patients underwent EBD using a through-the-scope balloon. Initial balloon dilatation was performed with a front-viewing endoscope. A side-viewing endoscope was used where negotiation across the stricture failed with a front-viewing endoscope. Dilatation was started at 8 mm diameter and was performed at 1-week intervals. The end point of dilatation was 15 mm diameter. In 18 patients successful balloon dilatation was possible with a front-viewing endoscope. A side-viewing endoscope was used in six patients as negotiation across the stricture was not possible with a front-viewing endoscope. In all six patients negotiation across the stricture followed by successful dilatation was successful with a side-viewing endoscope. Of the 25 patients included in this study, 24 (96%) achieved procedural success (18 with a front-viewing endoscope and 6 with a side-viewing endoscope) in 3-9 sessions. Our results show that EBD is a safe and effective option for caustic-induced GOO and in difficult cases a side-viewing endoscope can be used to achieve technical success.

  12. [Clinical experience of combined laparoscopic-endoscopic Heller myotomy and modified Dor fundoplication for cardiochalasia].

    PubMed

    Qiao, Xiaofang; Li, Jinlong; Xu, Hua; Wan, Xin; Zhu, Jiaming

    2017-08-25

    To investigate the efficacy of combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication for cardiochalasia patients. Clinical data of 11 cardiochalasia patients who underwent combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication by the same medical team from January 2015 to December 2016 at The Second Hospital of Jilin University were retrospectively analyzed. The procedure was as follows: an incision was made in the anterior wall of esophagus and dissection of esophageal muscular layer was performed, then the bulged esophageal mucosa was covered by the fundus after 180 degrees fold to the right (fundoplication), finally the gastric fundus was joined to the right diaphragmatic foot by 3 to 5 knotted suture. The efficacy was judged by the Eckardt scoring standard: the postoperative Eckardt score ≤3 points indicated effectiveness, otherwise the treatment was invalid. Combined laparoscopic-endoscopic lower esophageal sphincterotomy and modified Dor fundoplication was completed successfully in all the 11 patients without any subsequent laparotomy and death. The mean operative time was 85 (78 to 137) min, blood loss was 15 (5 to 35) ml, and no upper digestive tract perforation occurred. The mean postoperative hospital stay was 7.0(6 to 9) d. After the operation, the pressure of lower esophageal sphincter decreased significantly compared to that before operation [(5.31±6.23) mmHg vs. (35.72±17.13) mmHg, P<0.05], and the Eckardt score decreased significantly as well (0.53±0.56 vs. 6.17±1.17, P<0.05). During the follow-up of 2 to 23 months, there was no postoperative mortality. One case experienced mild gastroesophageal reflux 6 months after operation, and another patient had recurrent dysphagia 17 months after operation, who both were improved after receiving proton pump inhibitors or gastric dynamic drugs, and balloon dilation. Combined laparoscopic-endoscopic lower esophageal

  13. Basics of robotics and manipulators in endoscopic surgery.

    PubMed

    Rininsland, H H

    1993-06-01

    The experience with sophisticated remote handling systems for nuclear operations in inaccessible rooms can to a large extent be transferred to the development of robotics and telemanipulators for endoscopic surgery. A telemanipulator system is described consisting of manipulator, endeffector and tools, 3-D video-endoscope, sensors, intelligent control system, modeling and graphic simulation and man-machine interfaces as the main components or subsystems. Such a telemanipulator seems to be medically worthwhile and technically feasible, but needs a lot of effort from different scientific disciplines to become a safe and reliable instrument for future endoscopic surgery.

  14. Endoscopic and Photodynamic Therapy of Cholangiocarcinoma

    PubMed Central

    Meier, Benjamin; Caca, Karel

    2016-01-01

    Background Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Methods/Results Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. Conclusion More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA. PMID:28229075

  15. Laparoscopic nephroureterectomy: making management of upper-tract transitional-cell carcinoma entirely minimally invasive.

    PubMed

    Keeley, F X; Tolley, D A

    1998-04-01

    Endoscopic treatment of upper-tract transitional-cell carcinoma (TCC) is well established. Nevertheless, many patients still required major ablative surgery. We have applied our experience with laparoscopic nephrectomy to the performance of laparoscopic nephroureterectomy in order to make the management of upper-tract TCC entirely minimally invasive. Since 1993, we have performed 22 laparoscopic nephroureterectomies for upper-tract TCC. Initially, we excluded patients with tumors below the pelvic brim, but we now offer a trial of laparoscopy to all patients. We describe the evolution of our technique, which involves resecting the ureteral orifice prior to laparoscopic dissection of the kidney and ureter. We have had to convert three cases to open surgery, one each for bleeding, failure to progress, and unappreciated tumor extent. Operative times averaged 156 minutes, which compares well with contemporary times for open nephroureterectomy. Complication rates, transfusion requirements, and length of stay, although higher than those of laparoscopic nephrectomy, were all reduced in comparison with open nephroureterectomy.

  16. First bleeding episode from oesophageal varices in cirrhotic patients: a prospective study of endoscopic predictive factors.

    PubMed

    Colombo, E; Casiraghi, M A; Minoli, G; Prada, A; Terruzzi, V; Bortoli, A; Carnovali, M; Gullotta, R; Imperiali, G; Comin, U

    1995-09-01

    Two hundred patients affected by liver cirrhosis and oesophageal varices were studied in 9 Gastrointestinal Units in Lombardy (Northern Italy) in order to assess factors possibly related to variceal bleeding. Only patients without any previous episode of gastrointestinal bleeding were included in the prospective evaluation. For each patient demographic data, aetiology of cirrhosis, various clinical and biochemical parameters able to group patients into the three Child-Pugh Classes, endoscopic items for calculation of Beppu's and of NIEC prognostic scores were recorded on computerized cards. Patients were regularly interviewed every three months for one year and underwent an upper gastrointestinal endoscopy at enrollment, after six months and in case of bleeding. Within the twelve-month follow-up period, 29 out of the 200 patients (14%) bled and 52 out of 200 died (26%). In 16 of the 52 patients who died (59% of bleeding patients) death was directly related to gastrointestinal bleeding. Bleeding from oesophageal varices was endoscopically proven in 19/29 patients, in another 9 bleeding was classified as from unknown source and in one patient a bleeding gastric ulcer was diagnosed. Univariate analysis of all the recorded clinical, biochemical and endoscopic parameters, performed by Chi-square method and Fisher exact test showed that the presence of RWM (p < 0.001) was the only factor significantly associated to variceal bleeding within one year. Relationship between size of varices and bleeding was very close to the statistical significance but did not achieve it (p = 0.058).

  17. Design of illumination system in ring field capsule endoscope

    NASA Astrophysics Data System (ADS)

    Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi

    2011-03-01

    This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.

  18. Functional results in endoscopic Zenker's diverticulum surgery.

    PubMed

    Dissard, A; Gilain, L; Pastourel, R; Mom, T; Saroul, N

    2017-10-01

    The main objective of this retrospective study was to assess functional results in endoscopic Zenker's diverticulum surgery. The secondary objectives were to assess safety, identify recurrence risk factors, and determine optimal management of recurrence. From 2000 to 2014, 50 patients underwent endoscopic surgery for marsupialization of Zenker's diverticulum. Regurgitation and dysphagia were assessed on the FOIS scale, pre- and post-operatively. Recurrences and complications rates were determined retrospectively at a minimum 18 months' follow-up. Regurgitation and dysphagia improved in respectively 96% and 86% of patients. There was a 12% rate of complications, mostly minor. Mean hospital stay and time to return to oral feeding were 2.0 and 1.3 days respectively. Nine patients (18%) showed recurrence of symptoms, requiring revision surgery at a mean 2.7 years, performed endoscopically in the majority of cases. Only one recurrence risk factor was identified: small diverticulum size. Endoscopic Zenker's diverticulum surgery provided functional improvement in most cases. Safe and effective, it is currently the treatment of choice for Zenker's diverticulum. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Modifications in endoscopic practice for pediatric patients.

    PubMed

    Lightdale, Jenifer R; Acosta, Ruben; Shergill, Amandeep K; Chandrasekhara, Vinay; Chathadi, Krishnavel; Early, Dayna; Evans, John A; Fanelli, Robert D; Fisher, Deborah A; Fonkalsrud, Lisa; Hwang, Joo Ha; Kashab, Mouen; Muthusamy, V Raman; Pasha, Shabana; Saltzman, John R; Cash, Brooks D

    2014-05-01

    We recommend that endoscopy in children be performed by pediatric-trained endoscopists whenever possible. We recommend that adult-trained endoscopists coordinate their services with pediatricians and pediatric specialists when they are needed to perform endoscopic procedures in children. We recommend that endoscopy be performed within 24 hours in symptomatic pediatric patients with known or suspected ingestion of caustic substances. We recommend emergent foreign-body removal of esophageal button batteries, as well as 2 or more rare-earth neodymium magnets. We recommend that procedural and resuscitative equipment appropriate for pediatric use should be readily available during endoscopic procedures. We recommend that personnel trained specifically in pediatric life support and airway management be readily available during sedated procedures in children. We recommend the use of endoscopes smaller than 6 mm in diameter in infants and children weighing less than 10 kg. We recommend the use of standard adult duodenoscopes for performing ERCP in children who weigh at least 10 kg. We recommend the placement of 12F or 16F percutaneous endoscopic gastrostomy tubes in children who weigh less than 50 kg.

  20. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    PubMed

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  1. Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.

    PubMed

    Buss, A J; Been, M H; Borgers, R P; Stokroos, I; Melchers, W J; Peters, F T; Limburg, A J; Degener, J E

    2008-04-01

    Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to trace disinfection problems to individual endoscopes or washer-disinfectors. Our surveillance protocol included anterograde and retrograde sampling, a decision algorithm, genetic fingerprinting, and scanning electron microscopy. Over a period of 29 months we found an increasing number of patient-ready endoscopes testing positive for Candida species other than albicans, especially C. parapsilosis. These yeasts were also isolated from the washer-disinfectors. The number of positive tests for Candida species varied from 1 out of 21 to 14 out of 27 samples from nine frequently used endoscopes. The number of colony-forming units per milliliter ranged from 1 - 10 to 3000 for endoscopes and 0.002 to 0.06 for the washer disinfectors. DNA fingerprinting was not able to discriminate different strains within C. parapsilosis. Our protocol was able to detect a structural problem in the endoscope disinfection process. Retrograde sampling was crucial for this purpose, because it has much higher sensitivity than anterograde sampling. Endoscopes with damaged working channels are probably the source of the contamination problem with Candida species.

  2. Prior minimal endoscopic sphincterotomy to prevent pancreatitis related to endoscopic balloon sphincteroplasty

    PubMed Central

    Kanazawa, Ryo; Sai, Jin Kan; Ito, Tomoyasu; Miura, Hiroko; Ishii, Shigeto; Saito, Hiroaki; Tomishima, Ko; Shimizu, Ryo; Sato, Koki; Hayashi, Manabu; Watanabe, Sumio; Shiina, Shuichiro

    2016-01-01

    AIM To investigate the efficacy of prior minimal endoscopic sphincterotomy (EST) to prevent pancreatitis related to endoscopic balloon sphincteroplasty (EBS). METHODS After bile duct access was gained and cholangiogram confirmed the presence of stones < 8 mm in the common bile duct at endoscopic retrograde cholangiography, patients were subjected to minimal EST (up to one-third of the size the papilla) plus 8 mm EBS (EST-EBS group). The incidence of pancreatitis and the difference in serum amylase level after the procedure were examined and compared with those associated with 8-mm EBS alone in 32 patients of historical control (control group). RESULTS One hundred and five patients were included in the EST-EBS group, and complete stone removal was accomplished in all of them. The difference in serum amylase level after the procedure was - 25.0 (217.9) IU/L in the EST-EBS group and this value was significantly lower than the 365.5 (576.3) IU/L observed in the control group (P < 0.001). The incidence of post-procedure pancreatitis was 0% (0/105) in the EST-EBS group and 15.6% (5/32) in the control group (P < 0.001). CONCLUSION Prior minimal EST might be useful to prevent the elevation of serum amylase level and the occurrence of pancreatitis related to EBS. PMID:27803773

  3. Endoscopic closure of an iatrogenic rupture of upper esophagus (Lannier’s triangle) with the use of endoclips – case report and review of the literature

    PubMed Central

    Mantzoukis, Konstantinos; Papadimitriou, Kassiani; Kouvelis, Ioannis; Theocharidou, Athina; Zebekakis, Pantelis; Vital, Victor; Nikolaidis, Pavlos; Germanidis, Georgios

    2011-01-01

    We present a case report regarding a 74-year-old male with iatrogenic esophageal perforation, after an attempt to remove a food bolus impaction at Lannier’s triangle (proximal esophagus). The perforation was treated endoscopically (flexible EGD) by clip application in two sessions, with excellent outcome. Esophageal perforations occur rarely, usually following a medical procedure. The clinical manifestations are often insidious with potentially catastrophic complications. Although the majority of cases have been treated conservatively and/or operatively over the years, there is a rising tendency for non-operative endoscopic interventions due to the high morbidity and mortality rates seen even in specialized units. For this reason self-expandable stents, endoclips, tissue sealants and suturing devices have been used. A high degree of clinical suspicion is essential for successful management of esophageal perforations, as is early decision to intervene and respect for basic surgical principles such as prevention and limitation of extraesophageal contamination, prevention of reflux of gastric contents and restoration of gastrointestinal tract integrity. The published reports on the use of endoclips for repairing perforations of the proximal esophagus are rare. To our knowledge, this is the first case report regarding the endoscopic application of endoclips for the successful closure of an iatrogenic perforation at Lannier’s triangle. PMID:24714287

  4. Differences in displacement of the proximal and distal ends of mid-upper thoracic esophageal squamous cell carcinoma.

    PubMed

    Qiu, Guoqin; Wen, Dengshun; DU, Xianghui; Sheng, Liming; Zhou, Xia; Ji, Yongling; Bao, Wuan; Zhang, Danhong; Cheng, Lei

    2016-07-01

    In the present study, clips were used as markers to evaluate displacement differences between proximal and distal ends of esophageal tumors and to test whether their internal target volume (ITV) margins should be determined separately. A total of 23 patients with mid-upper thoracic esophageal squamous-cell carcinoma, a tumor length of ≤8 cm and an esophageal lumen suitable for endoscopic ultrasonography were recruited for the present study. Clips were implanted endoscopically at the proximal and distal ends of the esophageal tumor (upper and lower clips). In a further exploratory study on 16 of the patients, a third clip was placed at the distal esophagus 2 cm above the gastro-esophageal junction (GEJ) (cardiac clip). The clips were contoured for all 10 phases of the four-dimensional computed tomography and the maximum displacements of the clip centroids among different breathing phases in left-right (LR), superior-inferior (SI) and anterior-posterior (AP) directions were marked as x, y and z, respectively. The ITV margins that covered 95% of the LR, SI and AP motion were 2.89, 5.00 and 2.36 mm, respectively. Axial displacement (y) was greater than radial displacement (x, z; P<0.05). It was also revealed that LR(x), SI(y) and AP(z) displacement of cardiac clips was greater than that of upper or lower clips (P<0.05). Differences in the axial and radial displacement of the upper and lower clips indicated that axial and radial ITV margins should be determined separately. However, further study is required on patients in whom the distal tumor end is located in proximity to the GEJ.

  5. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  6. In-Use Evaluation of Peracetic Acid for High-Level Disinfection of Endoscopes.

    PubMed

    Chenjiao, Wu; Hongyan, Zhang; Qing, Gu; Xiaoqi, Zhong; Liying, Gu; Ying, Fang

    2016-01-01

    Many high-level disinfectants have been used for disinfection of endoscopes such as 2% glutaraldehyde (GA), 0.55% ortho-phthalaldehyde (OPA), and peracetic acid (PAA). Both GA and OPA are widely used in disinfection of endoscopes and have been previously discussed, but there is little research on the practical use of PAA as an endoscope disinfectant. An experimental model of a flexible gastrointestinal endoscope being contaminated with 9 strains of microorganism was designed. After the cleaning and disinfecting procedure was completed, we evaluated the biocidal activity (850 ppm PAA, 2% GA, and 0.55% OPA) on our flexible gastrointestinal endoscope model. We also evaluated sterilization effectiveness of PAA on other bacteria, including some antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile). The residual bacterial colony count number of the PAA-disinfected endoscope was significantly lower than that of the GA- and OPA-disinfected endoscopes. The biocidal effect and efficiency of the endoscope disinfection by PAA appeared to be better than either the GA- or OPA-disinfected endoscope. PAA has demonstrated a good sterilization effect on other bacterial species; of particular note are common antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile. The results of this study demonstrate that PAA is a fast and effective high-level disinfectant for use in the reprocessing of flexible endoscopes.

  7. Accuracy of endoscopic diagnosis of Helicobacter pylori infection according to level of endoscopic experience and the effect of training

    PubMed Central

    2013-01-01

    Background Accurate prediction of Helicobacter pylori infection status on endoscopic images can contribute to early detection of gastric cancer, especially in Asia. We identified the diagnostic yield of endoscopy for H. pylori infection at various endoscopist career levels and the effect of two years of training on diagnostic yield. Methods A total of 77 consecutive patients who underwent endoscopy were analyzed. H. pylori infection status was determined by histology, serology, and the urea breast test and categorized as H. pylori-uninfected, -infected, or -eradicated. Distinctive endoscopic findings were judged by six physicians at different career levels: beginner (<500 endoscopies), intermediate (1500–5000), and advanced (>5000). Diagnostic yield and inter- and intra-observer agreement on H. pylori infection status were evaluated. Values were compared between the two beginners after two years of training. The kappa (K) statistic was used to calculate agreement. Results For all physicians, the diagnostic yield was 88.9% for H. pylori-uninfected, 62.1% for H. pylori-infected, and 55.8% for H. pylori-eradicated. Intra-observer agreement for H. pylori infection status was good (K > 0.6) for all physicians, while inter-observer agreement was lower (K = 0.46) for beginners than for intermediate and advanced (K > 0.6). For all physicians, good inter-observer agreement in endoscopic findings was seen for atrophic change (K = 0.69), regular arrangement of collecting venules (K = 0.63), and hemorrhage (K = 0.62). For beginners, the diagnostic yield of H. pylori-infected/eradicated status and inter-observer agreement of endoscopic findings were improved after two years of training. Conclusions The diagnostic yield of endoscopic diagnosis was high for H. pylori-uninfected cases, but was low for H. pylori-eradicated cases. In beginners, daily training on endoscopic findings improved the low diagnostic yield. PMID:23947684

  8. Intravital endoscopic technology for real-time monitoring of inflammation caused in experimental periodontitis.

    PubMed

    Movila, Alexandru; Kajiya, Mikihito; Wisitrasameewong, Wichaya; Stashenko, Philip; Vardar-Sengul, Saynur; Hernandez, Maria; Thomas Temple, H; Kawai, Toshihisa

    2018-06-01

    We report a novel method for in situ imaging of microvascular permeability in inflamed gingival tissue, using state-of-the-art Cellvizio™ intravital endoscopic technology and a mouse model of ligature-induced periodontitis. The silk ligature was first placed at the upper left second molar. Seven days later, the ligature was removed, and the animals were intravenously injected with Evans blue. Evans blue dye, which selectively binds to blood albumin, was used to monitor the level of inflammation by monitoring vascular permeability in control non-diseased and ligature-induced experimental periodontitis tissue. More specifically, leakage of Evans blue-bound albumin from the micro-capillary to connective tissue indicates the state of inflammation occurring in the specific site. Evans blue leakage from blood vessels was imaged in situ by directly attaching the endoscope (mini Z tip) of the Cellvizio™ system to the gingival tissue without any surgical incision. Evans blue emission intensity was significantly elevated in gingiva of periodontitis lesions, but not control non-ligature placed gingiva, indicating that this technology can be used as a potential minimally invasive diagnostic tool to monitor the level of inflammation at the periodontal disease site. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. A high definition Mueller polarimetric endoscope for tissue characterisation (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel

    2016-03-01

    The mechanism of most medical endoscopes is based on the interaction between light and biological tissue, inclusive of absorption, elastic scattering and fluorescence. In essence, the metrics of those interactions are obtained from the fundamental properties of light as an electro-magnetic waves, namely, the radiation intensity and wavelength. As another fundamental property of light, polarisation can not only reveal tissue scattering and absorption information from a different perspective, but is also able to provide a fresh insight into directional tissue birefringence properties induced by birefringent compositions and anisotropic fibrous structures, such as collagen, elastin, muscle fibre, etc at the same time. Here we demonstrate a low cost high definition Muller polarimetric endoscope with minimal alteration of a rigid endoscope. By imaging birefringent tissue mimicking phantoms and a porcine bladder, we show that this novel endoscopic imaging modality is able to provide different information of interest from unpolarised endoscopic imaging, including linear depolarization, circular depolarization, birefringence, optic axis orientation and dichroism. This endoscope can potentially be employed for better tissue visualisation and benefit endoscopic investigations and intra-operative guidance.

  10. Flexible endoscopes: structure and function. The suction and biopsy channel.

    PubMed

    Holland, P

    2001-01-01

    Flexible endoscopes are complex medical instruments that are easily damaged. To maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the second in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first article discussed the air and water system. This article will focus specifically on the suction and biopsy channel system. The flexible endoscope is constructed of several systems that operate simultaneously to produce a highly technical, yet effective diagnostic and therapeutic medical device. These systems include the air and water system, the suction or operating channel system, the mechanical system, the endoscopic retrograde cholangiopancreatography (ERCP) elevator system, the optical system, and the electrical system. A review of the internal and external structure of the flexible endoscope and the functions of the channel system, including infection control issues, potential problems and evaluation, and prevention of minor problems to avoid expensive repairs, will be addressed.

  11. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.

    PubMed

    Herz, P R; Chen, Y; Aguirre, A D; Schneider, K; Hsiung, P; Fujimoto, J G; Madden, K; Schmitt, J; Goodnow, J; Petersen, C

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  12. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-µm axial resolution by use of a femtosecond Crforsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  13. Endoscopic retrograde cholangiopancreatography-associated AmpC Escherichia coli outbreak.

    PubMed

    Wendorf, Kristen A; Kay, Meagan; Baliga, Christopher; Weissman, Scott J; Gluck, Michael; Verma, Punam; D'Angeli, Marisa; Swoveland, Jennifer; Kang, Mi-Gyeong; Eckmann, Kaye; Ross, Andrew S; Duchin, Jeffrey

    2015-06-01

    We identified an outbreak of AmpC-producing Escherichia coli infections resistant to third-generation cephalosporins and carbapenems (CR) among 7 patients who had undergone endoscopic retrograde cholangiopancreatography at hospital A during November 2012-August 2013. Gene sequencing revealed a shared novel mutation in a bla CMY gene and a distinctive fumC/ fimH typing profile. To determine the extent and epidemiologic characteristics of the outbreak, identify potential sources of transmission, design and implement infection control measures, and determine the association between the CR E. coli and AmpC E. coli circulating at hospital A. We reviewed laboratory, medical, and endoscopy reports, and endoscope reprocessing procedures. We obtained cultures from endoscopes after reprocessing as well as environmental samples and conducted pulsed-field gel electrophoresis and gene sequencing on phenotypic AmpC isolates from patients and endoscopes. Cases were those infected with phenotypic AmpC isolates (both carbapenem-susceptible and CR) and identical bla CMY-2, fumC, and fimH alleles or related pulsed-field gel electrophoresis patterns. Thirty-five of 49 AmpC E. coli tested met the case definition, including all CR isolates. All cases had complicated biliary disease and had undergone at least 1 endoscopic retrograde cholangiopancreatography at hospital A. Mortality at 30 days was 16% for all patients and 56% for CR patients. Two of 8 reprocessed endoscopic retrograde cholangiopancreatography scopes harbored AmpC that matched case isolates by pulsed-field gel electrophoresis. Environmental cultures were negative. No breaches in infection control were identified. Endoscopic reprocessing exceeded manufacturer's recommended cleaning guidelines. Recommended reprocessing guidelines are not sufficient.

  14. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  15. Laparoscopic Adjustable Gastric Band (LAGB) Migration - Endoscopic Treatment Modalities.

    PubMed

    Klimczak, Tomasz; Szewczyk, Tomasz; Janczak, Przemysław; Jurałowicz, Piotr

    2016-12-01

    Laparoscopic adjustible gastric binding (LAGB) is one of most common surgical methods of treating obesity. Gastric band migration (erosion) is a typical LAGB complication, with a frequency of about 1-4%. The aim of the study was to present the possibilities of endoscopic diagnosis and treatment of this complication. The study was carried out in the Department of Gastroenterological, Oncological and General Surgery in Łódź. Between 2008 and 2015, 450 gastric bands were implanted using the laparoscopic technique in 318 (71%) women and 132 (29%) men. In this period 7 cases of band migration were diagnosed - 3 cases in men (2.3%) and 4 cases in women (1.3%), what presents 1.56% of general number of complications. Five out of 7 eroded bands were qualified for endoscopic removal. Four out of 5 qualified eroded bands were removed using the gastric band cutting technique. In one case we used the musculo-mucosal incision technique. In order to diagnose early perforations all patients underwent control passage examinations with oral contrast (gastrografin) 3-6 hours after the procedure. All 5 out of 5 qualified eroded gastric bands were successfully removed with the endoscopic method, which gives 100% success rate in own material. Two endoscopic methods were used: 1) endoscopic gastric band cutting, 2) endoscopic musculo-mucosal incision. Endoscopy gives a possibility of instant diagnosis of gastric band migration and early minimally invasive treatment. One of our endoscopic methods of removing the bands by making several incisions of the musculo-mucosal plicae has not yet been described in professional medical literature.

  16. Systems workplace for endoscopic surgery.

    PubMed

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  17. Endoscopic and laparoscopic treatment of gastroesophageal reflux.

    PubMed

    Watson, David I; Immanuel, Arul

    2010-04-01

    Gastroesophageal reflux is extremely common in Western countries. For selected patients, there is an established role for the surgical treatment of reflux, and possibly an emerging role for endoscopic antireflux procedures. Randomized trials have compared medical versus surgical management, laparoscopic versus open surgery and partial versus total fundoplications. However, the evidence base for endoscopic procedures is limited to some small sham-controlled studies, and cohort studies with short-term follow-up. Laparoscopic fundoplication has been shown to be an effective antireflux operation. It facilitates quicker convalescence and is associated with fewer complications, but has a similar longer term outcome compared with open antireflux surgery. In most randomized trials, antireflux surgery achieves at least as good control of reflux as medical therapy, and these studies support a wider application of surgery for the treatment of moderate-to-severe reflux. Laparoscopic partial fundoplication is an effective surgical procedure with fewer side effects, and it may achieve high rates of patient satisfaction at late follow-up. Many of the early endoscopic antireflux procedures have failed to achieve effective reflux control, and they have been withdrawn from the market. Newer procedures have the potential to fashion a surgical fundoplication. However, at present there is insufficient evidence to establish the safety and efficacy of endoscopic procedures for the treatment of gastroesophageal reflux, and no endoscopic procedure has achieved equivalent reflux control to that achieved by surgical fundoplication.

  18. Endoscopic pituitary surgery.

    PubMed

    Cappabianca, Paolo; Cavallo, Luigi Maria; de Divitiis, Oreste; Solari, Domenico; Esposito, Felice; Colao, Annamaria

    2008-01-01

    Pituitary surgery is a continuous evolving speciality of the neurosurgeons' armamentarium, which requires precise anatomical knowledge, technical skills and integrated appreciation of the pituitary pathophysiology. What we consider "pure" endoscopic transsphenoidal surgery is a procedure performed through the nose and the sphenoid bone, with the endoscope alone throughout the whole approach to visualize the surgical target area and without the use of any transsphenoidal retractor. It offers some advantages due to the endoscope itself: a superior close-up view of the relevant anatomy and an enlarged working angle are provided with an increased panoramic vision inside the surgical area. Concerning results in terms of mass removal, relief of clinical symptoms, cure of the underlying disease and complication rate, they are, at least, similar to those reported in the major microsurgical series, but patient compliance is by far better. Furthermore transsphenoidal endoscopy brings advantages to the patient (less nasal traumatism, no nasal packing, less post-op pain and usually quick recovery), to the surgeon (wider and closer view of the surgical target area, increase of the scientific activity as from the peer-reviewed literature on the topic in the last 10 years, smoothing of interdisciplinary cooperation), to the institution (shorter post-op hospital stay, increase of the case load). Besides, further progress and technological advance are expected from the close cooperation between different technologies and industries. Continuing works in such field of "minimalism" will offer further possibilities to provide the surgeon with even more effectiveness and safety, and, on the other hand, the patient with improvement of results.

  19. Endoscopic resection of gastric submucosal tumors: A comparison of endoscopic nontunneling with tunneling resection and a systematic review.

    PubMed

    Zhang, Qiang; Wang, Fei; Wei, Gong; Cai, Jian-Qun; Zhi, Fa-Chao; Bai, Yang

    2017-01-01

    Endoscopic tunneling resection is a relatively novel endoscopic technology for removing gastric submucosal tumors. Our study aimed to compare the differences between tunneling and nontunneling resection for gastric submucosal tumors. Resections of gastric submucosal tumors (n = 97) performed from 2010 to 2015 at our endoscopy center were reviewed, and PubMed was searched for clinical studies on gastric submucosal tumor resection by endoscopic nontunneling and tunneling techniques. At our endoscopy center, nontunneling (Group 1) and tunneling resection (Group 2) were performed for 78 and 19 submucosal tumors, respectively; median tumor diameters were 15 and 20 mm (P = 0.086), median procedural times were 50 and 75 min (P = 0.017), successful resection rates were 94.9% (74/78) and 89.5% (17/19) (P = 0.334), and en bloc resection rates were 95.9% (71/74) and 94.1% (16/17) (P = 0.569) in the Groups 1 and 2, respectively. Postoperative fever, delayed hemorrhage and perforation, hospitalization time, and hospitalization expense were statistically similar between the 2 groups. A literature review on gastric submucosal tumor resection suggested that the en bloc resection rates of the two methods for tumors with a median diameter of 15-30 mm were also high, and there were no relapses during the follow-up period. Both endoscopic nontunneling and tunneling resection seem to be effective and safe methods for removing relatively small gastric submucosal tumors. Compared with endoscopic nontunneling, tunneling resection does not seem to have distinct advantages for gastric submucosal tumors, and has a longer mean operative time.

  20. Development of terahertz endoscopic system for cancer detection

    NASA Astrophysics Data System (ADS)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2016-02-01

    Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.

  1. Endoscopic hemostasis for peptic ulcer bleeding: systematic review and meta-analyses of randomized controlled trials.

    PubMed

    Baracat, Felipe; Moura, Eduardo; Bernardo, Wanderley; Pu, Leonardo Zorron; Mendonça, Ernesto; Moura, Diogo; Baracat, Renato; Ide, Edson

    2016-06-01

    Peptic ulcer represents the most common cause of upper gastrointestinal bleeding. Endoscopic therapy can reduce the risks of rebleeding, continued bleeding, need for surgery, and mortality. The objective of this review is to compare the different modalities of endoscopic therapy. Studies were identified by searching electronic databases MEDLINE, Embase, Cochrane, LILACS, DARE, and CINAHL. We selected randomized clinical trials that assessed contemporary endoscopic hemostatic techniques. The outcomes evaluated were: initial hemostasis, rebleeding rate, need for surgery, and mortality. The possibility of publication bias was evaluated by funnel plots. An additional analysis was made, including only the higher-quality trials. Twenty-eight trials involving 2988 patients were evaluated. Injection therapy alone was inferior to injection therapy with hemoclip and with thermal coagulation when evaluating rebleeding and the need for emergency surgery. Hemoclip was superior to injection therapy in terms of rebleeding; there were no statistically significant differences between hemoclip alone and hemoclip with injection therapy. There was considerable heterogeneity in the comparisons between hemoclip and thermal coagulation. There were no statistically significant differences between thermal coagulation and injection therapy, though their combination was superior, in terms of rebleeding, to thermal coagulation alone. Injection therapy should not be used alone. Hemoclip is superior to injection therapy, and combining hemoclip with an injectate does not improve hemostatic efficacy above hemoclip alone. Thermal coagulation has similar efficacy as injection therapy; combining these appears to be superior to thermal coagulation alone. Therefore, we recommend the application of hemoclips or the combined use of injection therapy with thermal coagulation for the treatment of peptic ulcer bleeding.

  2. Minimal differences in prevalence and spectrum of organic disease at upper gastrointestinal endoscopy between selected secondary care patients with symptoms of gastro-oesophageal reflux or dyspepsia.

    PubMed

    Irvine, Andrew J; Pinto-Sanchez, Maria Ines; Bercik, Premysl; Moayyedi, Paul; Ford, Alexander C

    2017-04-01

    Gastro-oesophageal reflux and dyspepsia are felt to be separate upper gastrointestinal (GI) conditions. We aimed to measure the degree of overlap between them, and assess whether endoscopic findings differed. Demographic, symptom, upper GI endoscopy and histology data were collected from consecutive adults in secondary care. Patients were categorised according to whether they reported gastro-oesophageal reflux alone, dyspepsia alone or both, and patient demographics and endoscopic findings were compared. Of 1167 patients, 97 (8.3%) had gastro-oesophageal reflux alone, 571 (48.9%) dyspepsia alone, and 499 (42.8%) overlap. Patients with overlap symptoms were more likely to smoke, compared with those with gastro-oesophageal reflux alone, or dyspepsia alone (p = .009), but there were no other differences. Patients with gastro-oesophageal reflux alone or overlap had a higher prevalence of erosive oesophagitis (18.6% and 15.4% respectively, p < .001), but this was still the commonest diagnosis among those with dyspepsia alone (7.2%). No significant differences were seen in prevalence of other endoscopic findings. Gastro-oesophageal reflux and dyspepsia symptoms commonly overlap. There were minimal differences in demographics or spectrum of underlying organic disease between various symptom groups, suggesting that restrictive classifications according to predominant symptom may not be clinically useful.

  3. [Endoscopic sphincterotomy in choledocholithiasis and an intact gallbladder].

    PubMed

    Vladimirov, B; Petkov, R; Viiachki, I; Damianov, D; Iarŭmov, N

    1996-01-01

    Endoscopic sphincterotomy (ES) with extraction of calculi is a basic method of treating choledocholithiasis in post-cholecystectomy patients (8, 9). Endoscopic treatment contributes to a considerable reduction of the indications for reoperation. The existing views concerning ES done in patients with preserved gallbladder, especially in the era of laparoscopic surgery, are still conflicting (3, 6). There are several options: cholecystectomy with removal of calculi in the common bile duct by ES in a subsequent stage, or vice versa-primary ES with ensuring cholecystectomy. The undertaking of independent surgical or endoscopic treatment is likewise practicable (2, 6).

  4. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  5. Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.

    PubMed

    McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S

    2012-11-01

    A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities

  6. Endoscopic management of bile leakage after liver transplantation.

    PubMed

    Oh, Dong-Wook; Lee, Sung Koo; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong-Wan; Kim, Myung-Hwan

    2015-05-23

    Endoscopic retrograde cholangiopancreatography (ERCP) can be an effective treatment for bile leakage after liver transplantation. We evaluated the efficacy of endoscopic treatment in liver transplantation in patients who developed bile leaks. Forty-two patients who developed bile leaks after liver transplantation were included in the study. If a bile leak was observed on ERCP, a sphincterotomy was performed, and a nasobiliary catheter was then inserted. If a bile leak was accompanied by a bile duct stricture, either the stricture was dilated with balloons, followed by nasobiliary catheter insertion across the bile duct stricture, or endoscopic retrograde biliary drainage was performed. In the bile leakage alone group (22 patients), endoscopic treatment was technically successful in 19 (86.4%) and clinically successful in 17 (77.3%) cases. Among the 20 patients with bile leaks with bile duct strictures, endoscopic treatment was technically successful in 13 (65.0%) and clinically successful in 10 (50.0%) cases. Among the 42 patients who underwent ERCP, technical success was achieved in 32 (76.2%) cases and clinical success was achieved in 27 (64.3%) cases. ERCP is an effective and safe therapeutic modality for bile leaks after liver transplantation. ERCP should be considered as an initial therapeutic modality in post-liver transplantation patients.

  7. Advances in the endoscopic management of pancreatic collections.

    PubMed

    Ruiz-Clavijo, David; de la Higuera, Belen González; Vila, Juan J

    2015-04-16

    Treatment of pancreatic collections has experienced great progress in recent years with the emergence of alternative minimally invasive techniques comparing to the classic surgical treatment. Such techniques have been shown to improve outcomes of morbidity vs surgical treatment. The recent emergence of endoscopic drainage is noteworthy. The advent of endoscopic ultrasonography has been crucial for treatment of these specific lesions. They can be characterized, their relationships with neighboring structures can be evaluated and the drainage guided by this technique has been clearly improved compared with the conventional endoscopic drainage. Computed tomography is the technique of choice to characterize the recently published new classification of pancreatic collections. For this reason, the radiologist's role establishing and classifying in a rigorously manner the collections according to the new nomenclature is essential to making therapeutic decisions. Ideal scenario for comprehensive treatment of these collections would be those centers with endoscopic ultrasound and interventional radiology expertise together with hepatobiliopancreatic surgery. This review describes the different types of pancreatic collections: acute peripancreatic fluid collection, pancreatic pseudocysts, acute necrotic collection and walled-off necrosis; the indications and the contraindications for endoscopic drainage, the drainage technique and their outcomes. The integrated management of pancreatic collections according to their type and evolution time is discussed.

  8. Endoscopic Management of Bile Leakage after Liver Transplantation

    PubMed Central

    Oh, Dongwook; Lee, Sung Koo; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong-Wan; Kim, Myung-Hwan

    2015-01-01

    Background/Aims Endoscopic retrograde cholangiopancreatography (ERCP) can be an effective treatment for bile leakage after liver transplantation. We evaluated the efficacy of endoscopic treatment in liver transplantation in patients who developed bile leaks. Methods Forty-two patients who developed bile leaks after liver transplantation were included in the study. If a bile leak was observed on ERCP, a sphincterotomy was performed, and a nasobiliary catheter was then inserted. If a bile leak was accompanied by a bile duct stricture, either the stricture was dilated with balloons, followed by nasobiliary catheter insertion across the bile duct stricture, or endoscopic retrograde biliary drainage was performed. Results In the bile leakage alone group (22 patients), endoscopic treatment was technically successful in 19 (86.4%) and clinically successful in 17 (77.3%) cases. Among the 20 patients with bile leaks with bile duct strictures, endoscopic treatment was technically successful in 13 (65.0%) and clinically successful in 10 (50.0%) cases. Among the 42 patients who underwent ERCP, technical success was achieved in 32 (76.2%) cases and clinical success was achieved in 27 (64.3%) cases. Conclusions ERCP is an effective and safe therapeutic modality for bile leaks after liver transplantation. ERCP should be considered as an initial therapeutic modality in post-liver transplantation patients. PMID:25717048

  9. Endoscopic closure of duodenal perforations by using an over-the-scope clip: a randomized, controlled porcine study.

    PubMed

    von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel

    2010-01-01

    Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Quality assurance manual of endoscopic screening for gastric cancer in Japanese communities.

    PubMed

    Hamashima, Chisato; Fukao, Akira

    2016-09-02

    The Japanese government introduced endoscopic screening for gastric cancer in 2015 as a public policy based on the Japanese guidelines on gastric cancer screening. To provide appropriate endoscopic screening for gastric cancer in Japanese communities, we developed a quality assurance manual of endoscopic screening and recommend 10 strategies with their brief descriptions as follows: (i) Formulation of a committee responsible for implementing and managing endoscopic screening, and for deciding the suitable implementation methods in consideration of the local context; (ii) Development of an interpretation system that leads to a final judgement to standardize endoscopic examination and improve its accuracy; (iii) Preparation of management and reporting systems for adverse effects by the committee for safety management; (iv) Obtaining informed consent before operation following adequate explanations regarding the benefits and harms of endoscopic screening; (v) Avoidance of frequent screenings to reduce false-positive results and overdiagnosis. As a reference, the target age group is ≥50 years, and the screening interval is 2 years; (vi) Keeping the biopsy rate within 10% as post-biopsy bleeding may occur. Before endoscopic screening, any history of antithrombotic drug usage should be checked; (vii) Nonadministration of sedation in endoscopic screening for safety management; (viii) Adherence to proper endoscopic cleaning and disinfection to reduce infection; (ix) Use of a checklist to achieve optimal program preparation when municipal governments introduce endoscopic screening; (x) Identification of the aims and roles by referring to a checklist if primary care physicians decide to participate in endoscopic screening. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    PubMed

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  12. A high definition Mueller polarimetric endoscope for tissue characterisation

    NASA Astrophysics Data System (ADS)

    Qi, Ji; Elson, Daniel S.

    2016-05-01

    The contrast mechanism of medical endoscopy is mainly based on metrics of optical intensity and wavelength. As another fundamental property of light, polarization can not only reveal tissue scattering and absorption information from a different perspective, but can also provide insight into directional tissue birefringence properties to monitor pathological changes in collagen and elastin. Here we demonstrate a low cost wide field high definition Mueller polarimetric endoscope with minimal alterations to a rigid endoscope. We show that this novel endoscopic imaging modality is able to provide a number of image contrast mechanisms besides traditional unpolarized radiation intensity, including linear depolarization, circular depolarization, cross-polarization, directional birefringence and dichroism. This enhances tissue features of interest, and additionally reveals tissue micro-structure and composition, which is of central importance for tissue diagnosis and image guidance for surgery. The potential applications of the Mueller polarimetric endoscope include wide field early epithelial cancer diagnosis, surgical margin detection and energy-based tissue fusion monitoring, and could further benefit a wide range of endoscopic investigations through intra-operative guidance.

  13. [Three-dimensional endoscopic endonasal study of skull base anatomy].

    PubMed

    Abarca-Olivas, Javier; Monjas-Cánovas, Irene; López-Álvarez, Beatriz; Lloret-García, Jaime; Sanchez-del Campo, Jose; Gras-Albert, Juan Ramon; Moreno-López, Pedro

    2014-01-01

    Training in dissection of the paranasal sinuses and the skull base is essential for anatomical understanding and correct surgical techniques. Three-dimensional (3D) visualisation of endoscopic skull base anatomy increases spatial orientation and allows depth perception. To show endoscopic skull base anatomy based on the 3D technique. We performed endoscopic dissection in cadaveric specimens fixed with formalin and with the Thiel technique, both prepared using intravascular injection of coloured material. Endonasal approaches were performed with conventional 2D endoscopes. Then we applied the 3D anaglyph technique to illustrate the pictures in 3D. The most important anatomical structures and landmarks of the sellar region under endonasal endoscopic vision are illustrated in 3D images. The skull base consists of complex bony and neurovascular structures. Experience with cadaver dissection is essential to understand complex anatomy and develop surgical skills. A 3D view constitutes a useful tool for understanding skull base anatomy. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  14. A New Method for Endoscopic Sampling of Submucosal Tissue in the Gastrointestinal Tract: A Comparison of the Biopsy Forceps and a New Drill Instrument.

    PubMed

    Walther, Charles; Jeremiasen, Martin; Rissler, Pehr; Johansson, Jan L M; Larsson, Marie S; Walther, Bruno S C S

    2016-12-01

    Background Sampling of submucosal lesions in the gastrointestinal tract through a flexible endoscope is a well-recognized clinical problem. One technique often used is endoscopic ultrasound-guided fine-needle aspiration, but it does not provide solid tissue biopsies with preserved architecture for histopathological evaluation. To obtain solid tissue biopsies from submucosal lesions, we have constructed a new endoscopic biopsy tool and compared it in a crossover study with the standard double cupped forceps. Methods Ten patients with endoscopically verified submucosal lesions were sampled. The endoscopist selected the position for the biopsies and used the instrument selected by randomization. After a biopsy was harvested, the endoscopist chose the next site for a biopsy and again used the instrument picked by randomization. A total of 6 biopsies, 3 with the forceps and 3 with the drill instrument, were collected in every patient. Results The drill instrument resulted in larger total size biopsies (mm 2 ; Mann-Whitney U test, P = .048) and larger submucosal part (%) of the biopsies (Mann-Whitney U test, P = .003) than the forceps. Two patients were observed because of chest pain and suspicion of bleeding in 24 hours. No therapeutic measures were necessary to be taken. Conclusion The new drill instrument for flexible endoscopy can safely deliver submucosal tissue samples from submucosal lesions in the upper gastrointestinal tract. © The Author(s) 2016.

  15. Rare gastrointestinal lymphomas: The endoscopic investigation

    PubMed Central

    Vetro, Calogero; Bonanno, Giacomo; Giulietti, Giorgio; Romano, Alessandra; Conticello, Concetta; Chiarenza, Annalisa; Spina, Paolo; Coppolino, Francesco; Cunsolo, Rosario; Raimondo, Francesco Di

    2015-01-01

    Gastrointestinal lymphomas represent up to 10% of gastrointestinal malignancies and about one third of non-Hodgkin lymphomas. The most prominent histologies are mucosa-associated lymphoid tissue lymphoma and diffuse large B-cell lymphoma. However, the gastrointestinal tract can be the site of rarer lymphoma subtypes as a primary or secondary localization. Due to their rarity and the multifaceted histology, an endoscopic classification has not been validated yet. This review aims to analyze the endoscopic presentation of rare gastrointestinal lymphomas from disease diagnosis to follow-up, according to the involved site and lymphoma subtype. Existing, new and emerging endoscopic technologies have been examined. In particular, we investigated the diagnostic, prognostic and follow-up endoscopic features of T-cell and natural killer lymphomas, lymphomatous polyposis and mantle cell lymphoma, follicular lymphoma, plasma cell related disease, gastrointestinal lymphomas in immunodeficiency and Hodgkin’s lymphoma of the gastrointestinal tract. Contrarily to more frequent gastrointestinal lymphomas, data about rare lymphomas are mostly extracted from case series and case reports. Due to the data paucity, a synergism between gastroenterologists and hematologists is required in order to better manage the disease. Indeed, clinical and prognostic features are different from nodal and extranodal or the bone marrow (in case of plasma cell disease) counterpart. Therefore, the approach should be based on the knowledge of the peculiar behavior and natural history of disease. PMID:26265987

  16. Urodynamic changes in patients with anterior urethral valves: before and after endoscopic valve ablation.

    PubMed

    Kajbafzadeh, Abdol-Mohammad; Payabvash, Seyedmehdi; Karimian, Golnar

    2007-08-01

    To retrospectively review a series of children with anterior urethral valves (AUV), with emphasis on patterns of urodynamic change and long-term outcome of endoscopic treatment. We reviewed the medical records of eight patients who had undergone thorough radiological and urodynamic exams before and after treatment. The diagnosis of AUV was based on radiological imaging and confirmed by urethrocystoscopy. The valves were ablated through either transurethral fulguration or resection. The upper urinary tracts were studied by renal scan and ultrasonography before and after the procedure. Bladder function was assessed urodynamically 3 months after surgery. Uroflowmetry was performed as soon as the children were toilet trained. Endoscopic ablation of AUV was successful in all cases and no surgical complications occurred. The initial symptoms resolved in all boys. VUR disappeared in two out of three patients, and five children had bladder trabeculation that was resolved after surgery. The final outcome was successful in seven patients (88%). The major urodynamic dysfunction was bladder hypercontractility that resolved following valve ablation. The mean maximum voiding detrusor pressure (P(detmax)) decreased from 213.2+/-17.9 cmH(2)O to 80.7+/-9.9 cmH(2)O, 6 months after treatment (P<0.001). None of the patients had low-compliant bladder, detrusor instability or myogenic failure. The voiding pattern in all toilet-trained patients was staccato and of an interrupted shape prior to surgery, but changed to a normal bell-shaped voiding pattern following valve ablation. AUV should be considered in the differential diagnosis of patients presenting with infravesical obstruction. We recommend endoscopic valve ablation as the treatment of choice.

  17. Advanced shape tracking to improve flexible endoscopic diagnostics

    NASA Astrophysics Data System (ADS)

    Cao, Caroline G. L.; Wong, Peter Y.; Lilge, Lothar; Gavalis, Robb M.; Xing, Hua; Zamarripa, Nate

    2008-03-01

    Colonoscopy is the gold standard for screening for inflammatory bowel disease and colorectal cancer. Flexible endoscopes are difficult to manipulate, especially in the distensible and tortuous colon, sometimes leading to disorientation during the procedure and missed diagnosis of lesions. Our goal is to design a navigational aid to guide colonoscopies, presenting a three dimensional representation of the endoscope in real-time. Therefore, a flexible sensor that can track the position and shape of the entire length of the endoscope is needed. We describe a novel shape-tracking technology utilizing a single modified optical fiber. By embedding fluorophores in the buffer of the fiber, we demonstrated a relationship between fluorescence intensity and fiber curvature. As much as a 40% increase in fluorescence intensity was achieved when the fiber's local bend radius decreased from 58 mm to 11 mm. This approach allows for the construction of a three-dimensional shape tracker that is small enough to be easily inserted into the biopsy channel of current endoscopes.

  18. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    PubMed

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  19. Modified endoscopic medial maxillectomy for zygomatic implant salvage

    PubMed Central

    Tajudeen, Bobby A.; Adappa, Nithin D.; Palmer, James N.

    2016-01-01

    Objectives: Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. Methods: We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. Results: The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. Conclusion: We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant. PMID:28107147

  20. Endoscopic mucosal resection of colonic lesions: current applications and future prospects.

    PubMed

    Poppers, David M; Haber, Gregory B

    2008-05-01

    The introduction of submucosal fluid injection has remarkably extended the range of endoscopically resectable polyps. The limiting factor for endoscopic resection is not polyp size, but polyp depth. Endoscopic ultrasound is a useful adjunctive diagnostic tool to assess the depth of invasion. The success of are section ultimately depends on pathologic confirmation of a benign nature of this lesion or of a cancer limited to the mucosa. Selected well-differentiated cancers without lymphovascular invasion of the superficial submucosa can be successfully resected endoscopically.

  1. Hospitalized incidence and outcomes of upper gastrointestinal bleeding in Thailand.

    PubMed

    Sangchan, Apichat; Sawadpanitch, Kookwan; Mairiang, Pisaln; Chunlertrith, Kitti; Sukeepaisarnjaroen, Wattana; Sutra, Sumitr; Thavornpitak, Yupa

    2012-07-01

    Upper gastrointestinal bleeding (UGIB) is a common emergency gastrointestinal problem which has substantial mortality and health care resources use. The nationwide basic information on UGIB is not available in Thailand. To identify the hospitalized incidence, outcomes and hospitalization cost of patients who presented with UGIB in Thailand. Information on illness of in-patients from hospitals nationwide was retrieved from three major health schemes database in fiscal year 2010. The hospitalized incidence rate of UGIB was 166.3 admissions per 100,000 populations and the hospitalized incidence rate of non-variceal upper gastrointestinal bleeding (NVUGIB) and variceal bleeding were 152.9 and 13.5 admissions per 100,000 populations respectively. Endoscopic procedure was undertaken in 27.6% of NVUGIB admissions and 80.7% of variceal bleeding admissions. The in-hospital mortality rate, hospitalization cost and length of stay were higher in variceal bleeding patients compared with NVUGIB patients. UGIB is an important emergency gastrointestinal problem which has significant mortality and substantial health care resources consumption.

  2. Laparoscopic jejunostomy for obstructing upper gastrointestinal malignancies

    PubMed Central

    TSUJIMOTO, HIRONORI; HIRAKI, SHUICHI; TAKAHATA, RISA; NOMURA, SHINSUKE; ITO, NOZOMI; KANEMATSU, KYOHEI; HORIGUCHI, HIROYUKI; AOSASA, SUEFUMI; YAMAMOTO, JUNJI; HASE, KAZUO

    2015-01-01

    The aim of this study was to describe a minimally invasive laparoscopic jejunostomy (Lap-J) technique for obstruction due to upper gastrointestinal malignancies and evaluate the nutritional benefit of Lap-J during neoadjuvant chemotherapy (NAC) in cases with obstructing esophageal cancer. Under general anesthesia, the jejunum 20–30 cm distant from the Treitz ligament was pulled out through an extended umbilical laparoscopic incision and a jejunal tube was inserted to 30 cm. The loop of bowel was gently returned to the abdomen and the feeding tube was drawn through the abdominal wall via the left lower incision. The jejunum was then laparoscopically sutured to the anterior abdominal wall. Lap-J was performed in 26 cases. The median operative time was 82 min. The postoperative course was uneventful. Lap-J prior to NAC was not associated with a decrease in body weight or serum total protein during NAC, compared with patients who received NAC without Lap-J. This minimally invasive jejunostomy technique may be particularly useful in patients in whom endoscopic therapy is not feasible due to obstruction from upper gastrointestinal malignancies. PMID:26807238

  3. Experience of curing serious obstruction of advanced-stage upper digestive tract tumor using laser under endoscope

    NASA Astrophysics Data System (ADS)

    Mu, Hai-Bin; Zhang, Man-Ling; Zhang, Xiao-Qiang; Zhang, Feng-Qiu; Kong, De-Jia; Tang, Li-Bin

    1998-11-01

    The patients who suffer from upper digestive tract tumor, such as cancer of esophagus, cancer of cardia, all have serious obstruction and fail to get nutrition and can not bear the strike of the radiotherapy and chemotherapy. In order to reduce the obstruction symptom and suffering of the patients and to prolong their life time, since 1989, our hospital used the laser to cure the upper digestive tract tumor 11 cases with serious obstruction and got remarkable curative effect.

  4. Transnasal endoscopic medial maxillectomy in recurrent maxillary sinus inverted papilloma.

    PubMed

    Kamel, Reda H; Abdel Fattah, Ahmed F; Awad, Ayman G

    2014-12-01

    Maxillary sinus inverted papilloma entails medial maxillectomy and is associated with high incidence of recurrence. To study the impact of prior surgery on recurrence rate after transnasal endoscopic medial maxillectomy. Eighteen patients with primary and 33 with recurrent maxillary sinus inverted papilloma underwent transnasal endoscopic medial maxillectomy. Caldwell-Luc operation was the primary surgery in 12 patients, transnasal endoscopic resection in 20, and midfacial degloving technique in one. The follow-up period ranged between 2 to 19.5 years with an average of 8.8 years. Recurrence was detected in 8/51 maxillary sinus inverted papilloma patients (15.7 %), 1/18 of primary cases (5.5 %), 7/33 of recurrent cases (21.2 %); 3/20 of the transnasal endoscopic resection group (15%) and 4/12 of the Caldwell-Luc group (33.3%). Redo transnasal endoscopic medial maxillectomy was followed by a single recurrence in the Caldwell-Luc group (25%), and no recurrence in the other groups. Recurrence is more common in recurrent maxillary sinus inverted papilloma than primary lesions. Recurrent maxillary sinus inverted papilloma after Caldwell-Luc operation has higher incidence of recurrence than after transnasal endoscopic resection.

  5. The universal serial bus endoscope: design and initial clinical experience.

    PubMed

    Hernandez-Zendejas, Gregorio; Dobke, Marek K; Guerrerosantos, Jose

    2004-01-01

    Endoscopic forehead lift is a well-established procedure in aesthetic plastic surgery. Many agree that currently available video-endoscopic equipment is bulky, multipieced and sometimes cumbersome in the operating theater. A novel system, the Universal Serial Bus Endoscope (USBE) was designed to simplify and reduce the number of necessary equipment pieces in the endoscopic setup. The USBE is attached by a single cable to a Universal Serial Bus (USB) port of a laptop computer. A built-in miniaturized cold light source provides illumination. A built-in digital camera chip enables procedure recording. The real-time images and movies obtained with USBE are displayed on the computer's screen and recorded on the laptop's hard disk drive. In this study, 25 patients underwent endoscopic browlift using the USBE system to test its clinical usefulness, all with good results and without complications or need for revision. The USBE was found to be reliable and easier to use than current video-endoscope equipment. The operative time needed to complete the procedure by the authors was reduced approximately 50%. The design and main technical characteristics of the USBE are presented.

  6. [Endoscopic operation in the treatment of congenital duodenal membranous stenosis].

    PubMed

    Kong, Chihuan; Li, Long; Dong, Ning; Li, Xu; Zhang, Yanling

    2015-08-01

    To investigate the safety and efficacy of endoscopic duodenal valvectomy in the treatment of congenital duodenal membranous stenosis. Clinical data of two children with congenital duodenal membranous stenosis undergoing endoscopic duodenal valvectomy in our institute within October 2014 were analyzed retrospectively. This procedure was performed with Microknife XL and CRE balloon catheter through porous channel in the 9 mm flexible endoscope. The first case was a 2-year-old boy who received two endoscopic operations including duodenal diaphragm resection and duodenal dilatation because of incision retraction. The second case was a 19-month-old gril who received once endoscopic duodenal valvectomy. Duodenal obstruction of these two children was relieved after operation. Postoperative x-rays showed no perforation. They could play in the floor 6 hours after operation without any complains, drink water 12 hours, take liquid diets 2 days and half solid food 3 days after operation. During follow-up a month after operation, the body weight gained was 1.5 and 1.0 kg respectively, and the dietary components was significantly improved. Endoscopic duodenal valvectomy is feasible and effective in the treatment of congenital duodenal membranous stenosis.

  7. Endoscopic surgical management of sinonasal inverted papilloma extending to frontal sinuses.

    PubMed

    Takahashi, Yukiko; Shoji, Fumi; Katori, Yukio; Hidaka, Hiroshi; Noguchi, Naoya; Abe, Yasuhiro; Kakuta, Risako Kakuta; Suzuki, Takahiro; Suzuki, Yusuke; Ohta, Nobuo; Kakehata, Seiji; Okamoto, Yoshitaka

    2016-11-10

    Sinonasal inverted papilloma has been traditionally managed with external surgical approaches. Advances in imaging guidance systems, surgical instrumentation, and intraoperative multi-visualization have led to a gradual shift from external approaches to endoscopic surgery. However, for anatomical and technical reasons, endoscopic surgery of sinonasal inverted papilloma extending to the frontal sinuses is still challenging. Here, we present our experience in endoscopic surgical management of sinonasal inverted papilloma extending to one or both frontal sinuses. We present 10 cases of sinonasal inverted papilloma extending to the frontal sinuses and successfully removed by endoscopic median drainage (Draf III procedure) under endoscopic guidance without any additional external approach. The whole cavity of the frontal sinuses was easily inspected at the end of the surgical procedure. No early or late complications were observed. No recurrence was identified after an average follow-up period of 39.5 months. Use of an endoscopic median drainage approach to manage sinonasal inverted papilloma extending to one or both frontal sinuses is feasible and seems effective.

  8. Direct cost comparison of totally endoscopic versus open ear surgery.

    PubMed

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  9. High-level endoscope disinfection processes in emerging economies: financial impact of manual process versus automated endoscope reprocessing.

    PubMed

    Funk, S E; Reaven, N L

    2014-04-01

    The use of flexible endoscopes is growing rapidly around the world. Dominant approaches to high-level disinfection among resource-constrained countries include fully manual cleaning and disinfection and the use of automated endoscope reprocessors (AERs). Suboptimal reprocessing at any step can potentially lead to contamination, with consequences to patients and healthcare systems. To compare the potential results of guideline-recommended AERs to manual disinfection along three dimensions - productivity, need for endoscope repair, and infection transmission risk in India, China, and Russia. Financial modelling using data from peer-reviewed published literature and country-specific market research. In countries where revenue can be gained through productivity improvements, conversion to automated reprocessing has a positive direct impact on financial performance, paying back the capital investment within 14 months in China and seven months in Russia. In India, AER-generated savings and revenue offset nearly all of the additional operating costs needed to support automated reprocessing. Among endoscopy facilities in India and China, current survey-reported practices in endoscope reprocessing using manual soaking may place patients at risk of exposure to pathogens leading to infections. Conversion from manual soak to use of AERs, as recommended by the World Gastroenterology Organization, may generate cost and revenue offsets that could produce direct financial gains for some endoscopy units in Russia and China. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Identification of distinctive clinical significance in hospitalized patients with endoscopic duodenal mucosal lesions

    PubMed Central

    Han, Yeji; Jung, Hye-Kyung; Chang, Ji Young; Moon, Chang Mo; Kim, Seong-Eun; Shim, Ki-Nam; Jung, Sung-Ae; Kim, Joo-Young; Bae, Ji-Yun; Kim, Sae-In; Lee, Ji-Hyun; Park, Sanghui

    2017-01-01

    Background/Aims Duodenitis is not infrequent finding in patient undergoing endoscopy. However, hospitalized patients have a higher incidence of secondary duodenal mucosal lesions that might be related with inflammatory bowel disease (IBD), cytomegalovirus (CMV) infection, tuberculosis, immunologic disorders, or other rare infections. We aimed to identify clinicopathologic features of duodenal mucosal lesions in hospitalized patients. Methods All hospitalized patients having duodenal mucosal lesions were identified by endoscopic registration data and pathologic data query from 2011 to 2014. The diagnostic index was designed to be sensitive; however, a detailed review of medical record and endoscopic findings was undertaken to improve specificity. Secondary duodenal lesion was defined as having specific reason to explain the duodenal lesion. Results Among 6,334 hospitalized patients have undergone upper endoscopy, endoscopic duodenal mucosal lesions was detected in 475 patients. Secondary duodenal lesions was 21 patients (4.4%) and the most frequent secondary cause was IBD (n = 7). The mean age of secondary group was significantly lower than that in primary group (42.3 ± 18.9 years vs. 58.5 ± 16.8 years, p = 0.00), and nonsteroidal anti-inflammatory drugs were less frequently used in secondary group, but there was no differences of gender or presence of Helicobacter pylori. The involvement of distal part of duodenum including postbulbitis or panduodenitis was more frequently detected in secondary group than in primary group. By multivariate regression analysis, younger age of 29 years and the disease extent were significant predictors for the secondary mucosal lesions. Conclusions Secondary duodenal mucosal lesions with different pathophysiology, such as IBD or CMV infection, are rare. Disease extent and age seems the most distinctive feature of secondary duodenal mucosal lesions. PMID:28823115

  11. Esophagus: Endoscopic therapy for flat, dysplastic Barrett esophagus.

    PubMed

    Peery, Anne F; Shaheen, Nicholas J

    2011-04-01

    Both stepwise radical endoscopic resection (SRER) and radiofrequency ablation (RFA) are effective endoscopic strategies for the treatment of patients with flat, dysplastic Barrett esophagus. Findings from a randomized, controlled trial indicate that the two treatments have similar efficacy, but considerably more complications are associated with SRER compared with RFA.

  12. Hot biopsy forceps vs. endoscopic ultrasonography in determining the depth of gastric epithelial neoplasia: a simple novel method to decide whether or not to perform endoscopic submucosal dissection.

    PubMed

    Huikai, Li; Enqiang, Linghu

    2013-01-01

    It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.

  13. Endoscopic Resection of Gastric Submucosal Tumors: A Comparison of Endoscopic Nontunneling with Tunneling Resection and a Systematic Review

    PubMed Central

    Zhang, Qiang; Wang, Fei; Wei, Gong; Cai, Jian-Qun; Zhi, Fa-Chao; Bai, Yang

    2017-01-01

    Background/Aim: Endoscopic tunneling resection is a relatively novel endoscopic technology for removing gastric submucosal tumors. Our study aimed to compare the differences between tunneling and nontunneling resection for gastric submucosal tumors. Materials and Methods: Resections of gastric submucosal tumors (n = 97) performed from 2010 to 2015 at our endoscopy center were reviewed, and PubMed was searched for clinical studies on gastric submucosal tumor resection by endoscopic nontunneling and tunneling techniques. Results: At our endoscopy center, nontunneling (Group 1) and tunneling resection (Group 2) were performed for 78 and 19 submucosal tumors, respectively; median tumor diameters were 15 and 20 mm (P = 0.086), median procedural times were 50 and 75 min (P = 0.017), successful resection rates were 94.9% (74/78) and 89.5% (17/19) (P = 0.334), and en bloc resection rates were 95.9% (71/74) and 94.1% (16/17) (P = 0.569) in the Groups 1 and 2, respectively. Postoperative fever, delayed hemorrhage and perforation, hospitalization time, and hospitalization expense were statistically similar between the 2 groups. A literature review on gastric submucosal tumor resection suggested that the en bloc resection rates of the two methods for tumors with a median diameter of 15–30 mm were also high, and there were no relapses during the follow-up period. Conclusions: Both endoscopic nontunneling and tunneling resection seem to be effective and safe methods for removing relatively small gastric submucosal tumors. Compared with endoscopic nontunneling, tunneling resection does not seem to have distinct advantages for gastric submucosal tumors, and has a longer mean operative time. PMID:28139501

  14. New flexible endoscope for otologic application

    NASA Astrophysics Data System (ADS)

    Marchan, Mark L.

    1993-07-01

    Endoscopy has become an important procedure in many medical specialties. For the Otologist, however, space limitations within the ear have restricted development of endoscopic procedures. The desire for minimally invasive techniques in Otology has demonstrated itself through the work of numerous physicians who have performed procedures ranging from diagnostic inspection of the middle ear to viewing the interior of the cochlea. To assist in performing such endoscopic procedures, Xomed-Treace has developed a line of flexible fiberoptic endoscopes for use by the Otologist. These scopes combine illumination and imaging fiber bundles within a small diameter unit ranging in size from 0.8 mm to 1.2 mm. The 1.2 mm scope is produced with an angled, rigid stainless steel sheath. The 0.8 mm scope is flexible with the ability to articulate 120 degree(s) in one direction. The fiberscopes have been designed for the Otologist to produce a good resolution image while allowing ease of operation through ergonomics and consideration of the surgical anatomy.

  15. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  16. The application of percutaneous endoscopic colostomy to the management of obstructed defecation.

    PubMed

    Heriot, A G; Tilney, H S; Simson, J N L

    2002-05-01

    We describe the case of a 52-year woman with a 17-year history of obstructed defecation in whom all other standard treatments had failed and the patient had refused a colostomy. Her symptoms were controlled by percutaneous endoscopic colostomy with antegrade colonic irrigation. A percutaneous endoscopic colostomy tube was placed in the sigmoid colon endoscopically using a colonoscope and the patient irrigated two liters of water through the percutaneous endoscopic colostomy twice each day and was able to successfully evacuate her rectum without excess straining or discomfort. Percutaneous endoscopic colostomy is an alternative option to colostomy in the management of obstructed defecation.

  17. Successful treatment with a combination of endoscopic injection and irrigation with coca cola for gastric bezoar-induced gastric outlet obstruction.

    PubMed

    Lin, Chen-Sheng; Tung, Chun-Fang; Peng, Yen-Chun; Chow, Wei-Keung; Chang, Chi-Sen; Hu, Wei-Hsiung

    2008-01-01

    We report a case of gastric bezoar-induced gastric outlet obstruction that was successfully treated with a combination of endoscopic injection and irrigation with Coca Cola. A 73-year-old diabetic woman had a history of perforated peptic ulcer and had received pyloroplasty more than 20 years previously. She had been ingesting Pho Pu Zi (Cordia dichotoma Forst. f.) as an appetizer for 1 month. She presented with epigastric pain, nausea, and vomiting. Upper gastrointestinal endoscopy, performed at a local hospital, showed 2 gastric bezoars in the stomach, and 1 of them impacted at the pylorus. She was referred to our emergency department for removal of the gastric bezoars that were suspected to be causing gastric outlet obstruction. All attempts at endoscopic removal using a polypectomy snare, biopsy forceps and Dormia basket failed. We then injected Coca Cola directly into the bezoar mass, followed by irrigation with Coca Cola. Follow-up endoscopy was performed the next day, which revealed that the gastric bezoars had dissolved spontaneously.

  18. Histologic characteristics of gastric polyps in Korea: Emphasis on discrepancy between endoscopic forceps biopsy and endoscopic mucosal resection specimen

    PubMed Central

    Yoon, Won Jae; Lee, Dong Ho; Jung, Yong Jin; Jeong, Ji Bong; Kim, Ji Won; Kim, Byeong Gwan; Lee, Kook Lae; Lee, Kwang Hyuck; Park, Young Soo; Hwang, Jin-Hyeok; Kim, Jin-Wook; Kim, Nayoung; Lee, Jun Kyu; Jung, Hyun Chae; Yoon, Yong Bum; Song, In Sung

    2006-01-01

    AIM: To investigate histological characteristics of gastric polyps in the Korean population. METHODS: We reviewed endoscopic photographs and medical records of patients with gastric polyps who underwent endoscopic mucosal resection from April 1996 through February 2003. RESULTS: A total of 85 gastric polyps from 74 patients were reviewed. Male-to-female ratio was 1:1.96. Mean age was 59.9 ± 10.8 years. Multiple polyps were observed in 10.8%. Gastric polyps occurred most frequently in the antrum (58.8%). Pathological results on resected specimens were as follows: tubular adenoma 45.9%, hyperplastic polyp 31.8%, inflammatory polyp 9.4%, hamartoma 3.5%, fundic gland polyp 2.4%, tubulovillous adenoma 2.4%, adenocarcinoma 2.4%, dysplasia 1.1%, and mucosal pseudolipomatosis 1.1%. Discrepancy rate between endoscopic biopsy and pathology of resected specimens was 27.1%. There was no relationship between the size of the polyp and concordance rate. CONCLUSION: There is considerable discrepancy in histologic findings between endoscopic forceps biopsy and resected specimens. Approaches to review of the histology of an entire polyp should be performed, especially when an adenoma is suspected. PMID:16810753

  19. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    PubMed

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Endoscopic treatment of esophageal achalasia

    PubMed Central

    Esposito, Dario; Maione, Francesco; D’Alessandro, Alessandra; Sarnelli, Giovanni; De Palma, Giovanni D

    2016-01-01

    Achalasia is a motility disorder of the esophagus characterized by dysphagia, regurgitation of undigested food, chest pain, weight loss and respiratory symptoms. The most common form of achalasia is the idiopathic one. Diagnosis largely relies upon endoscopy, barium swallow study, and high resolution esophageal manometry (HRM). Barium swallow and manometry after treatment are also good predictors of success of treatment as it is the residue symptomatology. Short term improvement in the symptomatology of achalasia can be achieved with medical therapy with calcium channel blockers or endoscopic botulin toxin injection. Even though few patients can be cured with only one treatment and repeat procedure might be needed, long term relief from dysphagia can be obtained in about 90% of cases with either surgical interventions such as laparoscopic Heller myotomy or with endoscopic techniques such pneumatic dilatation or, more recently, with per-oral endoscopic myotomy. Age, sex, and manometric type by HRM are also predictors of responsiveness to treatment. Older patients, females and type II achalasia are better after treatment compared to younger patients, males and type III achalasia. Self-expandable metallic stents are an alternative in patients non responding to conventional therapies. PMID:26839644

  1. Endoscopic treatment of esophageal achalasia.

    PubMed

    Esposito, Dario; Maione, Francesco; D'Alessandro, Alessandra; Sarnelli, Giovanni; De Palma, Giovanni D

    2016-01-25

    Achalasia is a motility disorder of the esophagus characterized by dysphagia, regurgitation of undigested food, chest pain, weight loss and respiratory symptoms. The most common form of achalasia is the idiopathic one. Diagnosis largely relies upon endoscopy, barium swallow study, and high resolution esophageal manometry (HRM). Barium swallow and manometry after treatment are also good predictors of success of treatment as it is the residue symptomatology. Short term improvement in the symptomatology of achalasia can be achieved with medical therapy with calcium channel blockers or endoscopic botulin toxin injection. Even though few patients can be cured with only one treatment and repeat procedure might be needed, long term relief from dysphagia can be obtained in about 90% of cases with either surgical interventions such as laparoscopic Heller myotomy or with endoscopic techniques such pneumatic dilatation or, more recently, with per-oral endoscopic myotomy. Age, sex, and manometric type by HRM are also predictors of responsiveness to treatment. Older patients, females and type II achalasia are better after treatment compared to younger patients, males and type III achalasia. Self-expandable metallic stents are an alternative in patients non responding to conventional therapies.

  2. [New technique for safe removal of impacted foreign bodies in the upper gastrointestinal tract using reusable variceal "cap" (cup, cap or cylinder)].

    PubMed

    Chávez Rossell, Miguel

    2012-01-01

    The ingestion of a foreign body is one of the most common endoscopic emergencies. Foreign bodies in the upper gastrointestinal tract should be extracted as soon as possible to avoid serious complications such as perforation o bleeding. However, removals of foreign bodies with sharp edges are very difficult and can develop complications during their removal. Various devices have therefore been developed to prevent mucosal injury from the sharp edges during endoscopic extraction. We report a new technique for the successful foreign body extraction of upper digestive tract using the cap from six shooter variceal banding reused. We present 17 cases (9 males and 8 females). The types of foreign bodies removed were: chicken bones (n:7), fish bones (n:3), denture prosthesis (n:2), food bolus (n:2), long pin (n:1), golden thumb tack (n: 1) and press-through package (n:1). There were no complications. This new technique is safe and effective. Highlights its advantages: enhanced sight pharyngo esophageal junction, foreign bodies disimpact at that level, food bolus suck, avoid sharp object damage mucosal or scope and decrease time removal.

  3. Teaching peroral endoscopic myotomy (POEM) to surgeons in practice: an "into the fire" pre/post-test curriculum.

    PubMed

    Kishiki, Tomokazu; Lapin, Brittany; Wang, Chi; Jonson, Brandon; Patel, Lava; Zapf, Matthew; Gitelis, Matthew; Cassera, Maria A; Swanström, Lee L; Ujiki, Michael B

    2018-03-01

    With the increasing adoption of peroral endoscopic myotomy (POEM) as a first-line therapy for achalasia as well as a growing list of other indications, it is apparent that there is a need for effective training methods for both endoscopists in training and those already in practice. We present a hands-on-focused with pre- and post-testing methodology to teach these skills. Six POEM courses were taught by 11 experienced POEM endoscopists at two independent simulation laboratories. The training curriculum included a pre-training test, lectures and discussion, mentored hands-on instruction using live porcine and ex-plant models, and a post-training test. The scoring sheet for the pre- and post-tests assessed the POEM performance with a Likert-like scale measuring equipment setup, mucosotomy creation, endoscope navigation, visualization, myotomy, and closure. Participants were stratified by their experience with upper-GI endoscopy (Novices <100 cases vs. Experts ≥100 cases), and their data were analyzed and compared. Sixty-five participants with varying degrees of experience in upper-GI endoscopy and laparoscopic achalasia cases completed the training curriculum. Participants improved knowledge scores from 69.7 ± 17.1 (pre-test) to 87.7 ± 10.8 (post-test) (p < 0.01). POEM performance increased from 15.1 ± 5.1 to 25.0 ± 5.5 (out of 30) (p < 0.01) with the greatest gains in mucosotomy [1.7-4.4 (out of 5), p < 0.01] and equipment (3.4-4.7, p < 0.01). Novices had significantly lower pre-test scores compared with Experts in upper-GI endoscopy (overall pre-score: 11.9 ± 5.6 vs. 16.3 ± 4.6, p < 0.01). Both groups improved significantly after the course, and there were no differences in post-test scores (overall post-score: 23.9 ± 6.6 vs. 25.4 ± 5.1, p = 0.34) between Novices and Experts. A multimodal curriculum with procedural practice was an effective curricular design for teaching POEM to practitioners. The curriculum was specifically

  4. Endoscopic ultrasound and endoscopic retrograde cholangiopancreatography: Can they be successfully combined?

    PubMed

    Gornals, Joan B; Esteban, José Miguel; Guarner-Argente, Carlos; Marra-Lopez, Carlos; Repiso, Alejandro; Sendino, Oriol; Loras, Carme

    2016-11-01

    Endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) have much in common, including their main indications (biliopancreatic disorders), powerful therapeutic capacities and a steep learning curve. Over the years they have evolved from novel diagnostic procedures to interventional therapeutic techniques, but along different paths (different scopes or devices and endoscopists specializing exclusively in one or the other technique). However, EUS has gradually developed into a therapeutic technique that requires skills in the use of ERCP devices and stents, leading some ERCP specialists to explore the therapeutic potential of EUS. The corresponding literature, which has grown exponentially, includes recent experiments on combining the two techniques, which have gradually come to be used in routine care in a number of centers, with positive technical, clinical and financial outcomes. We review EUS and ERCP as individual or combined procedures for managing biliopancreatic disorders. Copyright © 2016 Elsevier España, S.L.U. y AEEH y AEG. All rights reserved.

  5. [Conservative management of upper tract urinary fistulae using ureteral trans-vesico-parietal stent].

    PubMed

    Le Guilchet, T; Audenet, F; Hurel, S; Beaugerie, A; Fontaine, E; Terrier, N; Timsit, M O; Mejean, A

    2016-03-01

    Ureteral stents and ureteral catheters externalized through the urethra are not ideal solutions to manage complicated upper urinary tract fistulae. We sought an effective method of drainage, minimally invasive, reproducible allowing a rapid patient's discharge. Between November 2013 and February 2015, an ureteral stent was exteriorized in trans-vesico-parietal by an endoscopic and percutaneous access in patients with complicated upper urinary tract fistulae. Monitoring of tolerance, complications and urinary fistula healing was performed. Nine consecutive patients had an ureteral stent exteriorized in trans-vesico-parietal to manage complicated upper urinary tract fistulae. There was no failure in introducing the catheter, or postoperative complication. Catheters were left in place on average 36.1days (24-55). The patients were able to return home with the catheter in place in 77.8% of cases. The tolerance of the catheter was good. All fistulae were able to be treated conservatively at the end of the drainage period. Trans-vesico-parietal ureteral catheters enable efficient and reproducible conservative treatment of upper tract urinary fistulae regardless of their cause. 5. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Huge gastric diospyrobezoars successfully treated by oral intake and endoscopic injection of Coca-Cola.

    PubMed

    Chung, Y W; Han, D S; Park, Y K; Son, B K; Paik, C H; Jeon, Y C; Sohn, J H

    2006-07-01

    A diospyrobezoar is a type of phytobezoar that is considered to be harder than any other types of phytobezoars. Here, we describe a new treatment modality, which effectively and easily disrupted huge gastric diospyrobezoars. A 41-year-old man with a history of diabetes mellitus was admitted with lower abdominal pain and vomiting. Upper gastrointestinal endoscopy revealed three huge, round diospyrobezoars in the stomach. He was made to drink two cans of Coca-Cola every 6 h. At endoscopy the next day, the bezoars were partially dissolved and turned to be softened. We performed direct endoscopic injection of Coca-Cola into each bezoar. At repeated endoscopy the next day, the bezoars were completely dissolved.

  7. Modified transnasal endoscopic medial maxillectomy through prelacrimal duct approach.

    PubMed

    Suzuki, Motohiko; Nakamura, Yoshihisa; Yokota, Makoto; Ozaki, Shinya; Murakami, Shingo

    2017-10-01

    We previously reported a modified endoscopic medial maxillectomy (modified transnasal endoscopic medial maxillectomy through prelacrimal duct approach [MTEMMPDA]) to resect inverted papilloma (IP), for which the inferior turbinate (IT) and nasolacrimal duct (ND) can be preserved. MTEMMPDA is a safe and effective method to obtain wide, straight access to the maxillary sinus (MS). However, there are few reported cases of patients who underwent MTEMMPDA, and even fewer of patients who underwent partial osteotomy of the apertura piriformis and the anterior wall of the MS. In this study, we analyzed the outcomes of 51 patients who underwent MTEMMPDA. Retrospective review. All patients who underwent MTEMMPDA at our hospital between January 2004 and December 2015 were included in this study. Fifty-one patients with sinonasal IP in the MS underwent MTEMMPDA. Recurrence was seen in the MS of one patient (follow-up of 2-138 months). The IT remained unchanged in all 51 patients without atrophy. We have not observed epiphora, eye discharge, dry nose, or persistent crusting after this surgery. Although seven patients had numbness around the upper lip after surgery, this had disappeared by 1 year after surgery. Additional partial osteotomy of the apertura piriformis and the anterior wall of the MS were done in eight patients. Deformation of the external nose was not seen. This approach appears to be a safe and effective method to resect IP in the MS, even if there is additional partial osteotomy of the apertura piriformis and the anterior wall of the MS. 4. Laryngoscope, 127:2205-2209, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Temporary endoscopic metallic stent for idiopathic esophageal achalasia.

    PubMed

    Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino

    2014-02-01

    Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.

  9. Update of the ICUD-SIU consultation on upper tract urothelial carcinoma 2016: treatment of low-risk upper tract urothelial carcinoma.

    PubMed

    Mandalapu, Rao S; Remzi, Mesut; de Reijke, Theo M; Margulis, Vitaly; Palou, J; Kapoor, A; Yossepowitch, Ofer; Coleman, Jonathan; Traxer, Olivier; Anderson, J Kyle; Catto, James; de la Rosette, Jean; O'Brien, Timothy; Zlotta, Anthony; Matin, Surena F

    2017-03-01

    The conservative management of upper tract urothelial carcinoma (UTUC) has historically been offered to patients with imperative indications. The recent International Consultation on Urologic Diseases (ICUD) publication on UTUC stratified treatment allocations based on high- and low-risk groups. This report updates the conservative management of the low-risk group. The ICUD for low-risk UTUC working group performed a thorough review of the literature with an assessment of the level of evidence and grade of recommendation for a variety of published studies in this disease space. We update these publications and provide a summary of that original report. There are no prospective randomized controlled studies to support surgical management guidelines. A risk-stratified approach based on clinical, endoscopic, and biopsy assessment allows selection of patients who could benefit from kidney-preserving procedures with oncological outcomes potentially similar to radical nephroureterectomy with bladder cuff excision, with the added benefit of renal function preservation. These treatments are aided by the development of high-definition flexible digital URS, multi-biopsies with the aid of access sheaths and other tools, and promising developments in the use of adjuvant topical therapy. Recent developments in imaging, minimally invasive techniques, multimodality approaches, and adjuvant topical regimens and bladder cancer prevention raise the hope for improved risk stratification and may greatly improve the endoscopic treatment for low-risk UTUC.

  10. Endoscopic versus Open Bursectomy for Prepatellar and Olecranon Bursitis

    PubMed Central

    Meric, Gokhan; Sargin, Serdar; Atik, Aziz; Ulusal, Ali Engin

    2018-01-01

    Objectives Bursitis of the olecranon and the patella are not rare disorders, and conservative management is successful in most cases. However, when patients do not respond to conservative treatment, open excisional surgery or, recently, endoscopic bursectomy, can be used. The aim of this study was to evaluate the results of open and endoscopic treatments of olecranon and prepatellar bursitis. Patients and methods Forty-nine patients (37 male and 12 female), who were treated with endoscopic bursectomy (25 patients) or open bursectomy (24 patients) were included in this study. Thirty patients had olecranon bursitis, while 19 patients had prepatellar bursitis. The patients’ average age was 61.1 ± 12.3 (range 33-81) years. All of the patients’ hospitalization and surgery times were recorded. The satisfaction of the patients was evaluated with a satisfaction scoring system, as well as by evaluating residual pain, the range of joint movement, and the cosmetic results of the procedure. Results The average follow-up time was 16 ± 9 months (range 12–27). The median operation time was 23.2 ± 3.5 minutes for the endoscopic bursectomy group and 26.4 ± 6.8 minutes for the open bursectomy group. The median hospitalization time was 0.56 ± 0.5 days (range 0-1 day) for the endoscopic group and 1 ± 0 days for the open bursectomy group (P<0.01). According to the patient satisfaction questionnaire, the endoscopic bursectomy group’s score was 8.5 ± 1.3 (range 5-10), and the open bursectomy group’s score was 5.29 ± 1.8 (range 1-9) (P<0.01). Conclusion Endoscopic bursectomy is a time-saving and efficient surgical treatment option for patients with prepatellar and olecranon bursitis. PMID:29805943

  11. Endoscopic versus Open Bursectomy for Prepatellar and Olecranon Bursitis.

    PubMed

    Meric, Gokhan; Sargin, Serdar; Atik, Aziz; Budeyri, Aydin; Ulusal, Ali Engin

    2018-03-27

    Objectives Bursitis of the olecranon and the patella are not rare disorders, and conservative management is successful in most cases. However, when patients do not respond to conservative treatment, open excisional surgery or, recently, endoscopic bursectomy, can be used. The aim of this study was to evaluate the results of open and endoscopic treatments of olecranon and prepatellar bursitis. Patients and methods Forty-nine patients (37 male and 12 female), who were treated with endoscopic bursectomy (25 patients) or open bursectomy (24 patients) were included in this study. Thirty patients had olecranon bursitis, while 19 patients had prepatellar bursitis. The patients' average age was 61.1 ± 12.3 (range 33-81) years. All of the patients' hospitalization and surgery times were recorded. The satisfaction of the patients was evaluated with a satisfaction scoring system, as well as by evaluating residual pain, the range of joint movement, and the cosmetic results of the procedure. Results The average follow-up time was 16 ± 9 months (range 12-27). The median operation time was 23.2 ± 3.5 minutes for the endoscopic bursectomy group and 26.4 ± 6.8 minutes for the open bursectomy group. The median hospitalization time was 0.56 ± 0.5 days (range 0-1 day) for the endoscopic group and 1 ± 0 days for the open bursectomy group (P<0.01). According to the patient satisfaction questionnaire, the endoscopic bursectomy group's score was 8.5 ± 1.3 (range 5-10), and the open bursectomy group's score was 5.29 ± 1.8 (range 1-9) (P<0.01). Conclusion Endoscopic bursectomy is a time-saving and efficient surgical treatment option for patients with prepatellar and olecranon bursitis.

  12. Early experience with endoscopic lumbar sympathectomy for plantar hyperhidrosis.

    PubMed

    Singh, Sanjay; Kaur, Simranjit; Wilson, Paul

    2016-05-01

    We describe our endoscopic lumbar sympathectomy technique and our early experience using it to treat plantar hyperhidrosis. We reviewed 20 lumbar sympathectomies performed in our vascular unit for plantar hyperhidrosis in 10 patients from 2011 and 2014. Demographics and outcomes were analyzed and a review of the literature conducted. All procedures were carried out endoscopically with no intraoperative or postoperative morbidity. Plantar anhidrosis was achieved in all the patients, although two patients (20%) suffered a relapse. Unwanted side-effects occurred in the form of compensatory sweating in three patients (30%) and post-sympathectomy neuralgia in two patients (20%). None of the patients experienced sexual dysfunction. Management of plantar hyperhidrosis may be based upon a therapeutic ladder starting with conservative measures and working up to surgery depending on the severity of the disease. Minimally invasive (endoscopic) sympathectomy for the thoracic chain is well established, but minimally invasive sympathectomy for the lumbar chain is a relatively new technique. Endoscopic lumbar sympathectomy provides an effective, minimally invasive method of surgical management, but long-term data are lacking. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  13. Does Lymphocytic Colitis Always Present with Normal Endoscopic Findings?

    PubMed Central

    Park, Hye Sun; Han, Dong Soo; Ro, Youngouk; Eun, Chang Soo; Yoo, Kyo-Sang

    2015-01-01

    Background/Aims Although normal endoscopic findings are, as a rule, part of the diagnosis of microscopic colitis, several cases of macroscopic lesions (MLs) have been reported in collagenous colitis, but hardly in lymphocytic colitis (LC). The aim of this study was to investigate the endoscopic, clinical, and histopathologic features of LC with MLs. Methods A total of 14 patients with LC who were diagnosed between 2005 and 2010 were enrolled in the study. Endoscopic, clinical, and histopathologic findings were compared retrospectively according to the presence or absence of MLs. Results MLs were observed in seven of the 14 LC cases. Six of the MLs exhibited hypervascularity, three exhibited exudative bleeding and one exhibited edema. The patients with MLs had more severe diarrhea and were taking aspirin or proton pump inhibitors. More intraepithelial lymphocytes were observed during histologic examination in the patients with MLs compared to the patients without MLs, although this difference was not significant. The numbers of mononuclear cells and neutrophils in the lamina propria were independent of the presence or absence of MLs. Conclusions LC does not always present with normal endoscopic findings. Hypervascularity and exudative bleeding are frequent endoscopic findings in patients with MLs. PMID:25167800

  14. Various upper endoscopic findings of acute esophageal thermal injury induced by diverse food: a case series.

    PubMed

    Lee, Yu Mi; Kim, Sun Moon; Kim, Ji Young; Song, Hyun Jung; Koo, Hoon Sup; Song, Kyung Ho; Kim, Yong Seok; Huh, Kyu Chan

    2014-09-01

    Esophageal thermal injury caused by food has been reported to occur mostly after drinking hot liquid food, and is known to produce alternating white and red linear mucosal bands. In addition, thermal injury caused by ingestion of hot solid foods is documented to be a cause of esophageal ulcers or pseudomembranes. From January 2006 to August 2012, five patients with suspected esophageal thermal injury underwent esophagogastroduodenoscopy with biopsy. A "candy-cane" appearance was observed in one case, pseudomembrane was observed in two cases, an esophageal ulcer was observed in one case, and a friable and edematous mucosa was noted in one case. We believe that the endoscopic findings of esophageal thermal injury depend on the following factors: causative materials, amount of food consumed, exposure period, and time to endoscopy after the incident. Therefore, physicians who encounter patients with suspected esophageal thermal injury should carefully take the patient's history considering these factors.

  15. Diagnosis and therapy of non-variceal upper gastrointestinal bleeding

    PubMed Central

    Biecker, Erwin

    2015-01-01

    Non-variceal upper gastrointestinal bleeding (UGIB) is defined as bleeding proximal to the ligament of Treitz in the absence of oesophageal, gastric or duodenal varices. The clinical presentation varies according to the intensity of bleeding from occult bleeding to melena or haematemesis and haemorrhagic shock. Causes of UGIB are peptic ulcers, Mallory-Weiss lesions, erosive gastritis, reflux oesophagitis, Dieulafoy lesions or angiodysplasia. After admission to the hospital a structured approach to the patient with acute UGIB that includes haemodynamic resuscitation and stabilization as well as pre-endoscopic risk stratification has to be done. Endoscopy offers not only the localisation of the bleeding site but also a variety of therapeutic measures like injection therapy, thermocoagulation or endoclips. Endoscopic therapy is facilitated by acid suppression with proton pump inhibitor (PPI) therapy. These drugs are highly effective but the best route of application (oral vs intravenous) and the adequate dosage are still subjects of discussion. Patients with ulcer disease are tested for Helicobacter pylori and eradication therapy should be given if it is present. Non-steroidal anti-inflammatory drugs have to be discontinued if possible. If discontinuation is not possible, cyclooxygenase-2 inhibitors in combination with PPI have the lowest bleeding risk but the incidence of cardiovascular events is increased. PMID:26558151

  16. Endoscopic management of ingested foreign bodies and food impactions.

    PubMed

    Malick, K Jane

    2013-01-01

    Endoscopy plays a major role in the management of foreign bodies and food impactions. Because of their frequent occurrence and potential for complications, it is important for the gastroenterology nurse and associate to gain an understanding of the incidence, diagnosis, and management of patients who present with ingested foreign bodies or food impaction. This article summarizes the clinical approach to patient: assessment, preparation for endoscopic procedure, preparation of endoscopic accessories, and follow-up care. Finally, an interesting case presentation highlights key components of caring for patients requiring endoscopic intervention.

  17. Holographic high-resolution endoscopic image recording

    NASA Astrophysics Data System (ADS)

    Bjelkhagen, Hans I.

    1991-03-01

    Endoscopic holography or endoholography combines the features of endoscopy and holography. The purpose of endoholographic imaging is to provide the physician with a unique means of extending diagnosis by providing a life-like record of tissue. Endoholographic recording will provide means for microscopic examination of tissue and in some cases may obviate the need to excise specimens for biopsy. In this method holograms which have the unique properties of three-dimensionality large focal depth and high resolution are made with a newly designed endoscope. The endoscope uses a single-mode optical fiber for illumination and single-beam reflection holograms are recorded in close contact with the tissue at the distal end of the endoscope. The holograms are viewed under a microscope. By using the proper combinations of dyes for staining specific tissue types with various wavelengths of laser illumination increased contrast on the cellular level can be obtained. Using dyes such as rose bengal in combination with the 514. 5 nm line of an argon ion laser and trypan blue or methylene blue with the 647. 1 nm line of a krypton ion laser holograms of the stained colon of a dog showed the architecture of the colon''s columnar epithelial cells. It is hoped through chronological study using this method in-vivo an increased understanding of the etiology and pathology of diseases such as Crohn''s diseases colitis proctitis and several different forms of cancer will help

  18. High-resolution imaging using endoscopic holography

    NASA Astrophysics Data System (ADS)

    Bjelkhagen, Hans I.

    1990-08-01

    Endoscopic holography or endoholography combines the features of endoscopy and holography. The purpose of endoholographic imaging is to provide the physician with a unique means of extending diagnosis by providing a life-like record of tissue. Endoholographic recording will provide means for microscopic examination of tissue and in some cases may obviate the need to excise specimens for biopsy. In this method holograms which have the unique properties of three-dimensionality large focal depth and high resolution are made with a newly designed endoscope. The endoscope uses a single-mode optical fiber for illumination and single-beam reflection holograms are recorded in close contact with the tissue at the distal end of the endoscope. The holograms are viewed under a microscope. By using the proper combinations of dyes for staining specific tissue types with various wavelengths of laser illumination increased contrast on the cellular level can be obtained. Using dyes such as rose bengal in combination with the 514. 5 nm line of an argon ion laser and trypan blue or methylene blue with the 647. 1 nm line of a krypton ion laser holograms of the stained colon of a dog showed the architecture of the colon''s columnar epithelial cells. It is hoped through chronological study using this method in-vivo an increased understanding of the etiology and pathology of diseases such as Crohn''s diseases colitis proctitis and several different forms of cancer will help to their control. 1.

  19. History, instrumentation, and techniques of flexible endoscopic laser surgery in horses.

    PubMed

    Blikslager, A T; Tate, L P

    2000-08-01

    There are clearly a number of applications for which flexible endoscopic laser surgery has become the state of the art in equine surgery, and the Nd:YAG laser seems to be the most versatile instrument for this type of surgery. Nevertheless, it is critical to understand the advantages and disadvantages of each laser technique. For example, the Nd:YAG laser used in a noncontact fashion seems to be superior when ablation of tissue is required such as treatment of upper airway masses. Conversely, contact Nd:YAG laser techniques have proven themselves to be superior when more precise cutting is advantageous such as treatment of epiglottic entrapment. Ultimately, it seems that a range of lasers is necessary to ensure selection of the most appropriate technique, adding significantly to the expense of equipment but improving the outcome for a range of equine diseases.

  20. The Efficacy of Endoscopic Palliation of Obstructive Jaundice in Hepatocellular Carcinoma

    PubMed Central

    Park, Semi; Park, Jeong Youp; Chung, Moon Jae; Chung, Jae Bock; Park, Seung Woo; Han, Kwang-Hyub; Song, Si Young

    2014-01-01

    Purpose Obstructive jaundice in patients with hepatocellular carcinoma (HCC) is uncommon (0.5-13%). Unlike other causes of obstructive jaundice, the role of endoscopic intervention in obstructive jaundice complicated by HCC has not been clearly defined. The aim of this study was to evaluate the clinical characteristics of obstructive jaundice caused by HCC and predictive factors for successful endoscopic intervention. Materials and Methods From 1999 to 2009, 54 patients with HCC who underwent endoscopic intervention to relieve obstructive jaundice were included. We defined endoscopic intervention as a clinical success when the obstructive jaundice was relieved within 4 weeks. Results Clinical success was achieved in 23 patients (42.6%). Patients in the clinical success group showed better Child-Pugh liver function (C-P grade A or B/C; 17/6 vs. 8/20), lower total bilirubin levels (8.1±5.3 mg/dL vs. 23.1±10.4 mg/dL) prior to the treatment, and no history of alcohol consumption. The only factor predictive of clinical success by multivariate analysis was low total bilirubin level at the time of endoscopic intervention, regardless of history of alcohol consumption [odds ratio 1.223 (95% confidence interval, 1.071-1.396), p=0.003]. The cut-off value of pre-endoscopic treatment total bilirubin level was 12.8 mg/dL for predicting the clinical prognosis. Median survival after endoscopic intervention in the clinical success group was notably longer than that in the clinical failure group (5.6 months vs. 1.5 months, p≤0.001). Conclusion Before endoscopic intervention, liver function, especially total bilirubin level, should be checked to achieve the best clinical outcome. Endoscopic intervention can be helpful to relieve jaundice in well selected patients with HCC. PMID:25048484

  1. Lower incidence of complications in endoscopic nasobiliary drainage for hilar cholangiocarcinoma.

    PubMed

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Haba, Shin; Kudo, Taiki; Taya, Yoko A; Kawahata, Shuhei; Kubota, Yoshimasa; Kubo, Kimitoshi; Eto, Kazunori; Ehira, Nobuyuki; Yamato, Hiroaki; Onodera, Manabu; Sakamoto, Naoya

    2016-05-10

    To identify the most effective endoscopic biliary drainage technique for patients with hilar cholangiocarcinoma. In total, 118 patients with hilar cholangiocarcinoma underwent endoscopic management [endoscopic nasobiliary drainage (ENBD) or endoscopic biliary stenting] as a temporary drainage in our institution between 2009 and 2014. We retrospectively evaluated all complications from initial endoscopic drainage to surgery or palliative treatment. The risk factors for biliary reintervention, post-endoscopic retrograde cholangiopancreatography (post-ERCP) pancreatitis, and percutaneous transhepatic biliary drainage (PTBD) were also analyzed using patient- and procedure-related characteristics. The risk factors for bilateral drainage were examined in a subgroup analysis of patients who underwent initial unilateral drainage. In total, 137 complications were observed in 92 (78%) patients. Biliary reintervention was required in 83 (70%) patients. ENBD was significantly associated with a low risk of biliary reintervention [odds ratio (OR) = 0.26, 95%CI: 0.08-0.76, P = 0.012]. Post-ERCP pancreatitis was observed in 19 (16%) patients. An absence of endoscopic sphincterotomy was significantly associated with post-ERCP pancreatitis (OR = 3.46, 95%CI: 1.19-10.87, P = 0.023). PTBD was required in 16 (14%) patients, and Bismuth type III or IV cholangiocarcinoma was a significant risk factor (OR = 7.88, 95%CI: 1.33-155.0, P = 0.010). Of 102 patients with initial unilateral drainage, 49 (48%) required bilateral drainage. Endoscopic sphincterotomy (OR = 3.24, 95%CI: 1.27-8.78, P = 0.004) and Bismuth II, III, or IV cholangiocarcinoma (OR = 34.69, 95%CI: 4.88-736.7, P < 0.001) were significant risk factors for bilateral drainage. The endoscopic management of hilar cholangiocarcinoma is challenging. ENBD should be selected as a temporary drainage method because of its low risk of complications.

  2. Percutaneous transgastric irrigation drainage in combination with endoscopic necrosectomy in necrotizing pancreatitis (with videos).

    PubMed

    Raczynski, Susanne; Teich, Niels; Borte, Gudrun; Wittenburg, Henning; Mössner, Joachim; Caca, Karel

    2006-09-01

    Endoscopic drainage of pancreatic acute and chronic pseudocysts and pancreatic necrosectomy have been shown to be beneficial for critically ill patients, with complete endoscopic resolution rates of around 80%. Our purpose was to describe an improved endoscopic technique used to treat pancreatic necrosis. Case report. University hospital. Two patients with large retroperitoneal necroses were treated with percutaneous transgastric retroperitoneal flushing tubes and a percutaneous transgastric jejunal feeding tube by standard percutaneous endoscopic gastrostomy access in addition to endoscopic necrosectomy. Intensive percutaneous transgastric flushing in combination with percutaneous normocaloric enteral nutrition and repeated endoscopic necrosectomy led to excellent outcomes in both patients. Small number of patients. The "double percutaneous endoscopic gastrostomy" approach for simultaneous transgastric drainage and normocaloric enteral nutrition in severe cases of pancreatic necroses is safe and effective. It could be a promising improvement to endoscopic transgastric treatment options in necrotizing pancreatitis.

  3. Endoscopic management of intrabiliary-ruptured hepatic hydatid cyst.

    PubMed

    Singh, Virendra; Reddy, Deevaguntla Chandrasekhar; Verma, Ganga Ram; Singh, Gurpreet

    2006-06-01

    Intrabiliary rupture of hepatic hydatid cyst causes serious morbidity and mortality. These patients are usually managed surgically. We evaluated the feasibility and outcome of an alternative method of treatment of these patients. Seven patients with ruptured hepatic hydatid into the biliary tract underwent endoscopic treatment consisting of endoscopic sphincterotomy, cyst material extraction and hypertonic saline lavage via nasocystic catheter. Median age of patients was 40 years (range 17-50 years) with a male:female ratio of 2:5. Abdominal pain, jaundice and fever were seen in all patients. Six out of seven patients were positive for hydatid serology. All patients were successfully treated by endoscopic sphincterotomy, clearance of cyst material and hypertonic saline lavage. On a follow-up of 6 months to 4 years (median, 3.5 years), ultrasonography, computed tomography of the abdomen and magnetic resonance imaging of the abdomen showed a complete cure. There were no complications related to procedure. This study demonstrates endoscopic treatment as one of the therapeutic options of ruptured hepatic hydatid cyst into the biliary tract.

  4. Confocal endomicroscopy for in vivo microscopic analysis of upper gastrointestinal tract premalignant and malignant lesions.

    PubMed

    Gheorghe, Cristian; Iacob, Razvan; Becheanu, Gabriel; Dumbrav Abreve, Mona

    2008-03-01

    Confocal LASER endomicroscopy (CLE) is a new endoscopic technique which allows subsurface in vivo microscopic analysis during ongoing endoscopy, using systemically or topically administered fluorescent agents. It allows targeted biopsies to be taken, potentially improving the diagnostic rate in certain gastrointestinal diseases. Worldwide experience with CLE for upper gastrointestinal malignant and premalignant lesions is still reduced. Potential clinical applications are presented, including diagnosis of NERD, Barrett's esophagus, atrophic gatritis, gastric intestinal metaplasia and dysplasia, gastric adenomatous or hyperplastic polyps, gastric cancer.

  5. [Diagnostic utility of endoscopic ultrasonography elastography and contrast-enhanced harmonic endoscopic ultrasonography in a patient with type 2 autoimmune pancreatitis].

    PubMed

    Yokode, Masataka; Shiomi, Hideyuki; Itai, Ryosuke; Mikami, Sakae; Yamashita, Yukimasa; Nakano, Ryota; Ezaki, Takeshi; Masuda, Atsuhiro; Zen, Yoh

    2018-01-01

    A referring hospital diagnosed a 57-year-old man with a pancreatic head mass. The initial endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) was inconclusive because of the small sample size. Endoscopic ultrasonography elastography (EUS-EG) and contrast-enhanced harmonic endoscopic ultrasonography (CE-EUS), conducted at our institute, raised the possibility of mass-forming pancreatitis or autoimmune pancreatitis (AIP). A repeat EUS-FNA revealed inflammatory changes, including a neutrophilic duct injury suggestive of type 2 AIP. The pancreatic lesion responded well to the steroid therapy. The present case suggests that EUS-EG and CE-EUS may be useful for diagnostic exclusion of pancreatic cancers, and the combined use of EUS-EG and CE-EUS, with EUS-FNA, may help characterize inflammatory pancreatic lesions.

  6. Provocative Endoscopy to Identify Bleeding Site in Upper Gastrointestinal Bleeding: A Novel Approach in Transarterial Embolization.

    PubMed

    Kamo, Minobu; Fuwa, Sokun; Fukuda, Katsuyuki; Fujita, Yoshiyuki; Kurihara, Yasuyuki

    2016-07-01

    This report describes a novel approach to endoscopically induce bleeding by removing a clot from the bleeding site during angiography for upper gastrointestinal (UGI) hemorrhage. This procedure enabled accurate identification of the bleeding site, allowing for successful targeted embolization despite a negative initial angiogram. Provocative endoscopy may be a feasible and useful option for angiography of obscure bleeding sites in patients with UGI arterial hemorrhage. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of the tip-bending response in clinically used endoscopes.

    PubMed

    Rozeboom, Esther D; Reilink, Rob; Schwartz, Matthijs P; Fockens, Paul; Broeders, Ivo A M J

    2016-04-01

    Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.

  8. The Regulatory Perspectives on Endoscopic Devices for Obesity.

    PubMed

    Marrone, April K; Antonino, Mark J; Silverstein, Joshua S; Betz, Martha W; Venkataraman-Rao, Priya; Golding, Martin; Cordray, Diane; Cooper, Jeffrey W

    2017-04-01

    The recent increase in US Food and Drug Administration-approved weight-loss devices has diversified obesity treatment options. The regulatory pathways for endoscopically placed weight-loss devices and considerations for clinical trials are discussed, including the benefit-risk paradigm intended to aid in weight-loss-device trial development. Also discussed is the benefit-risk analysis of recently approved endoscopic devices. A strategic priority of the FDA Center for Devices and Radiological Health is to increase the use of patient input in decision making. Thus, we consider how endoscopic weight-loss devices with profiles similar to those that have been approved may be viewed in a patient preference study. Published by Elsevier Inc.

  9. [Endoscopic assistance in surgery of cerebellopontine angle tumors].

    PubMed

    Poshataev, V K; Shimansky, V N; Tanyashin, S V; Karnaukhov, V V

    2014-01-01

    During the period of 2010-2012, 33 patients with cerebellopontine angle tumors were operated on at the Burdenko Neurosurgical Institute (Moscow, Russia) using different types of endoscopic assistance. All patients were operated on via the retrosigmoid suboccipital approach in semi-sitting and prone positions. 30° and 70° endoscopes were used during the surgery. Endoscopic assistance allowed us to increase the completeness of tumor removal and to reduce the risk of postoperative complications by retaining the anatomic integrity of cranial nerves and vascular structures in the base of the posterior cranial fossa. These benefits made it possible to maintain and improve quality of life in patients with CPA tumors in the postoperative period.

  10. Endoscopic colloid cyst excision: surgical techniques and nuances.

    PubMed

    Azab, Waleed Abdelfattah; Najibullah, Mustafa; Yosef, Waleed

    2017-06-01

    Endoscopic excision of colloid cysts is currently well established as a minimally invasive and highly effective technique that is associated with less morbidity in comparison to microsurgical resection. Operative charts and videos of patients undergoing endoscopic colloid cyst excision were retrieved from the senior author's database of endoscopic procedures and reviewed. This revealed nine trans-foraminal and three trans-septal procedures. Description of the surgical techniques was then formulated. Variation of the technique is based on the specific patho-anatomical features of the colloid cyst being resected. For the trans-foraminal approach, we think that the rotational technique is associated with a more complete removal of the cyst wall and consequently lower recurrence rate.

  11. Immediate detection of endoscopic retrograde cholangiopancreatography-related periampullary perforation: Fluoroscopy or endoscopy?

    PubMed Central

    Motomura, Yasuaki; Akahoshi, Kazuya; Gibo, Junya; Kanayama, Kenji; Fukuda, Shinichiro; Hamada, Shouhei; Otsuka, Yoshihiro; Kubokawa, Masaru; Kajiyama, Kiyoshi; Nakamura, Kazuhiko

    2014-01-01

    AIM: To investigate the causes and intraoperative detection of endoscopic retrograde cholangiopancreatography (ERCP)-related perforations to support immediate or early diagnosis. METHODS: Consecutive patients who underwent ERCP procedures at our hospital between January 2008 and June 2013 were retrospectively enrolled in the study (n = 2674). All procedures had been carried out using digital fluoroscopic assistance with the patient under conscious sedation. For patients showing alterations in the gastrointestinal anatomy, a short-type double balloon enteroscope had been applied. Cases of perforation had been identified by the presence of air in or leakage of contrast medium into the retroperitoneal space, or upon endoscopic detection of an abdominal cavity related to the perforated lumen. For patients with ERCP-related perforations, the data on medical history, endoscopic findings, radiologic findings, diagnostic methods, management, and clinical outcomes were used for descriptive analysis. RESULTS: Of the 2674 ERCP procedures performed during the 71-mo study period, only six (0.22%) resulted in perforations (male/female, 2/4; median age: 84 years; age range: 57-97 years). The cases included an endoscope-related duodenal perforation, two periampullary perforations related to endoscopic sphincterotomy, two periampullary perforations related to endoscopic papillary balloon dilation, and a periampullary or bile duct perforation secondary to endoscopic instrument trauma. No cases of guidewire-related perforation occurred. The video endoscope system employed in all procedures was only able to immediately detect the endoscope-related perforation; the other five perforation cases were all detected by subsequent digital fluoroscope applied intraoperatively (at a median post-ERCP intervention time of 15 min). Three out of the six total perforation cases, including the single case of endoscope-related duodenal injury, were surgically treated; the remaining three cases were

  12. Long-term results after endoscopic drainage and necrosectomy of symptomatic pancreatic fluid collections.

    PubMed

    Seewald, Stefan; Ang, Tiing Leong; Richter, Hugo; Teng, Karl Yu Kim; Zhong, Yan; Groth, Stefan; Omar, Salem; Soehendra, Nib

    2012-01-01

    To determine the immediate and long-term results of endoscopic drainage and necrosectomy for symptomatic pancreatic fluid collections. The data of 80 patients with symptomatic pancreatic fluid collections (mean diameter: 11.7 cm, range 3-20; pseudocysts: 24/80, abscess: 20/80, infected walled-off necrosis: 36/80) referred for endoscopic management from October 1997 to March 2008 were analyzed retrospectively. Endoscopic drainage techniques included endoscopic ultrasound (EUS)-guided aspiration (2/80), EUS-guided transenteric drainage (70/80) and non-EUS-guided drainage across a spontaneous transenteric fistula (8/80). Endoscopic necrosectomy was carried out in 49/80 (abscesses: 14/20; infected necrosis: 35/36). Procedural complications were bleeding (12/80), perforation (7/80), portal air embolism (1/80) and Ogilvie Syndrome (1/80). Initial technical success was achieved in 78/80 (97.5%) and clinical resolution of the collections was achieved endoscopically in 67/80 (83.8%), with surgery required in 13/80 (perforation: four; endoscopically inaccessible areas: two; inadequate drainage: seven). Within 6 months five patients required surgery due to recurrent fluid collections; over a mean follow up of 31 months, surgery was required in four more patients due to recurrent collections as a consequence of underlying pancreatic duct abnormalities that could not be treated endoscopically. The long-term success of endoscopic treatment was 58/80 (72.5%). Endoscopic drainage of symptomatic pancreatic fluid collections is safe and effective, with excellent immediate and long-term results. Endoscopic necrosectomy has a risk of serious complications. The underlying pancreatic duct abnormalities must be addressed to prevent recurrence of fluid collections. © 2011 The Authors. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.

  13. [GERD: endoscopic antireflux therapies].

    PubMed

    Caca, K

    2006-08-02

    A couple of minimally-invasive, endoscopic antireflux procedures have been developed during the last years. Beside endoscopic suturing these included injection/implantation technique of biopolymers and application of radiofrequency. Radiofrequency (Stretta) has proved only a very modest effect, while implantation techniques have been abandoned due to lack of long-term efficacy (Gatekeeper) or serious side effects (Enteryx). While first generation endoluminal suturing techniques (EndoCinch, ESD) demonstrated a proof of principle their lack of durability, due to suture loss, led to the development of a potentially durable transmural plication technique (Plicator). In a prospective-randomized, sham-controlled trial the Plicator procedure proved superiority concerning reflux symptoms, medication use and esophageal acid exposure (24-h-pH-metry). While long-term data have to be awaited to draw final conclusions, technical improvements will drive innovation in this field.

  14. Similar Efficacy of Proton-Pump Inhibitors vs H2-Receptor Antagonists in Reducing Risk of Upper Gastrointestinal Bleeding or Ulcers in High-Risk Users of Low-Dose Aspirin.

    PubMed

    Chan, Francis K L; Kyaw, Moe; Tanigawa, Tetsuya; Higuchi, Kazuhide; Fujimoto, Kazuma; Cheong, Pui Kuan; Lee, Vivian; Kinoshita, Yoshikazu; Naito, Yuji; Watanabe, Toshio; Ching, Jessica Y L; Lam, Kelvin; Lo, Angeline; Chan, Heyson; Lui, Rashid; Tang, Raymond S Y; Sakata, Yasuhisa; Tse, Yee Kit; Takeuchi, Toshihisa; Handa, Osamu; Nebiki, Hiroko; Wu, Justin C Y; Abe, Takashi; Mishiro, Tsuyoshi; Ng, Siew C; Arakawa, Tetsuo

    2017-01-01

    It is not clear whether H 2 -receptor antagonists (H2RAs) reduce the risk of gastrointestinal (GI) bleeding in aspirin users at high risk. We performed a double-blind randomized trial to compare the effects of a proton pump inhibitor (PPI) vs a H2RA antagonist in preventing recurrent upper GI bleeding and ulcers in high-risk aspirin users. We studied 270 users of low-dose aspirin (≤325 mg/day) with a history of endoscopically confirmed ulcer bleeding at 8 sites in Hong Kong and Japan. After healing of ulcers, subjects with negative results from tests for Helicobacter pylori resumed aspirin (80 mg) daily and were assigned randomly to groups given a once-daily PPI (rabeprazole, 20 mg; n = 138) or H2RA (famotidine, 40 mg; n = 132) for up to 12 months. Subjects were evaluated every 2 months; endoscopy was repeated if they developed symptoms of upper GI bleeding or had a reduction in hemoglobin level greater than 2 g/dL and after 12 months of follow-up evaluation. The adequacy of upper GI protection was assessed by end points of recurrent upper GI bleeding and a composite of recurrent upper GI bleeding or recurrent endoscopic ulcers at month 12. During the 12-month study period, upper GI bleeding recurred in 1 patient receiving rabeprazole (0.7%; 95% confidence interval [CI], 0.1%-5.1%) and in 4 patients receiving famotidine (3.1%; 95% CI, 1.2%-8.1%) (P = .16). The composite end point of recurrent bleeding or endoscopic ulcers at month 12 was reached by 9 patients receiving rabeprazole (7.9%; 95% CI, 4.2%-14.7%) and 13 patients receiving famotidine (12.4%; 95% CI, 7.4%-20.4%) (P = .26). In a randomized controlled trial of users of low-dose aspirin at risk for recurrent GI bleeding, a slightly lower proportion of patients receiving a PPI along with aspirin developed recurrent bleeding or ulcer than of patients receiving an H2RA with the aspirin, although this difference was not statistically significant. ClincialTrials.gov no: NCT01408186. Copyright © 2017 AGA

  15. Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.

    PubMed

    Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho

    2015-03-01

    Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.

  16. Transnasal Endoscope Locked in a Bent Position Causing Difficult Withdrawal

    PubMed Central

    Kumada, Takashi; Hisanaga, Yasuhiro

    2014-01-01

    We report a rare but severe complication of routine transnasal esophagogastroduodenoscopy (EGD). The tip of a transnasal endoscope was locked in a bent position. Since the bent tip was unable to be returned to a neutral position, the snare from another endoscope inserted transorally was used to straighten it, which allowed the transnasal endoscope to be withdrawn with only mild injury to the gastric mucosa. Endoscopists should be aware of this complication and how to manage it. PMID:26157831

  17. Solo-Surgeon Retroauricular Approach Endoscopic Thyroidectomy.

    PubMed

    Lee, Doh Young; Baek, Seung-Kuk; Jung, Kwang-Yoon

    2017-01-01

    This study aimed to evaluate the feasibility and efficacy of solo-surgeon retroauricular thyroidectomy. For solo-surgery, we used an Endoeye Flex Laparo-Thoraco Videoscope (Olympus America, Inc.). A Vitom Karl Storz holding system (Karl Storz GmbH & Co.) composed of several bars connected by a ball-joint system was used for fixation of endoscope. A snake retractor and a brain-spoon retractor were used on the sternocleidomastoid. Endoscopic thyroidectomy using the solo-surgeon technique was performed in 10 patients having papillary thyroid carcinoma. The mean patient age was 36.0 ± 11.1 years, and all patients were female. There were no postoperative complications such as vocal cord paralysis and hematoma. When compared with the operating times and volume of drainage of a control group of 100 patients who underwent surgery through the conventional retroauricular approach between May 2013 and December 2015, the operating times and volume of drainage were not significantly different (P = .781 and .541, respectively). Solo-surgeon retroauricular thyroidectomy is safe and feasible when performed by a surgeon competent in endoscopic thyroidectomy.

  18. [Risk management for endoscopic surgery].

    PubMed

    Kimura, Taizo

    2010-05-01

    The number of medical accidents in endoscopic surgery has recently increased. Surgical complications caused by inadequate preparation or immature technique or those resulting in serious adverse outcomes may be referred to as medical accidents. The Nationwide Survey of Endoscopic Surgery showed that bile duct injury and uncontrollable bleeding were seen in 0.68% and in 0.58%, respectively, of cholecystectomy patients; interoperative and postoperative complications in 0.84% and in 3.8%, respectively, of gastric cancer surgery patients; and operative complications in 6.74% of bowel surgery patients. Some required open repair, and 49 patients died. The characteristic causes of complications in endoscopic surgery are a misunderstanding of anatomy, handling of organs outside the visual field, burn by electrocautery, and injuries caused by forceps. Bleeding that requires a laparotomy for hemostasis is also a complication. Furthermore, since the surgery is usually videorecorded, immature techniques resulting in complications are easily discovered. To decrease the frequency of accidents, education through textbooks and seminars, training using training boxes, simulators, or animals, proper selection of the surgeon depending on the difficulty of the procedure, a low threshold for conversion to laparotomy, and use of the best optical equipment and surgical instruments are important. To avoid malpractice lawsuits, informed consent obtained before surgery and proper communication after accidents are necessary.

  19. Clinical guidelines for endoscopic mucosal resection of non-pedunculated colorectal lesions.

    PubMed

    Albéniz, Eduardo; Pellisé, María; Gimeno García, Antonio Z; Lucendo, Alfredo José; Alonso Aguirre, Pedro A; Herreros de Tejada, Alberto; Álvarez, Marco Antonio; Fraile, María; Herráiz Bayod, Maite; López Rosés, Leopoldo; Martínez Ares, David; Ono, Akiko; Parra Blanco, Adolfo; Redondo, Eduardo; Sánchez Yagüe, Andrés; Soto, Santiago; Díaz Tasende, José; Montes Díaz, Marta; Téllez, Manuel Rodríguez; García, Orlando; Zuñiga Ripa, Alba; Hernández Conde, Marta; Alberca de Las Parras, Fernando; Gargallo, Carla; Saperas, Esteban; Navas, Miguel Muñoz; Gordillo, Javier; Ramos Zabala, Felipe; Echevarría, José Manuel; Bustamante, Marco; González Haba, Mariano; González Huix, Ferrán; González Suárez, Begoña; Vila Costas, Juan José; Guarner Argente, Carlos; Múgica, Fernando; Cobián, Julyssa; Rodríguez Sánchez, Joaquín; López Viedma, Bartolomé; Pin, Noel; Marín Gabriel, José Carlos; Nogales, Óscar; de la Peña, Joaquín; Navajas León, Francisco Javier; León Brito, Helena; Remedios, David; Esteban, José Miguel; Barquero, David; Martínez Cara, Juan Gabriel; Martínez Alcalá, Felipe; Fernández Urién, Ignacio; Valdivielso, Eduardo

    2018-03-01

    This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  20. Endoscopic Submucosal Dissection: Indications and Application in Western Endoscopy Practice.

    PubMed

    Bourke, Michael J; Neuhaus, Horst; Bergman, Jacques J

    2018-05-01

    Endoscopic submucosal dissection was developed in Japan, early in this century, to provide a minimally invasive yet curative treatment for the large numbers of patients with early gastric cancer identified by the national screening program. Previously, the majority of these patients were treated surgically at substantial cost and with significant risk of short- and long-term morbidity. En-bloc excision of these early cancers, most with a limited risk of nodal metastasis, allowed complete staging of the tumor, stratification of the subsequent therapeutic approach, and potential cure. This transformative innovation changed the nature of endoscopic treatment for superficial mucosal neoplasia and, ultimately, for the first time allowed endoscopists to assert that the early cancer had been definitively cured. Subsequently, Western endoscopists have increasingly embraced the therapeutic possibilities offered by endoscopic submucosal dissection, but with some justifiable scientific caution. Here we provide an evidence-based critical appraisal of the role of endoscopic submucosal dissection in advanced endoscopic tissue resection. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.