Structural Phase Evolution in Ultrasonic-Assisted Friction Stir Welded 2195 Aluminum Alloy Joints
NASA Astrophysics Data System (ADS)
Eliseev, A. A.; Fortuna, S. V.; Kalashnikova, T. A.; Chumaevskii, A. V.; Kolubaev, E. A.
2017-10-01
The authors examined the structural and phase state of fixed joints produced by method of friction stir welding (FSW) and ultrasonic-assisted friction stir welding (UAFSW) from extruded profile of aluminum alloy AA2195. In order to identify the role of ultrasonic application in the course of welding, such characteristics, as volume fraction and average size of secondary particles are compared in the base material and stir zones of FSW and UAFSW joints. By applying the methods of SEM and TEM analysis, researchers established the complex character of phase transitions as a result of ultrasonic application.
Delrue, Steven; Tabatabaeipour, Morteza; Hettler, Jan; Van Den Abeele, Koen
2016-05-01
Friction stir welding (FSW) is a promising technology for the joining of aluminum alloys and other metallic admixtures that are hard to weld by conventional fusion welding. Although FSW generally provides better fatigue properties than traditional fusion welding methods, fatigue properties are still significantly lower than for the base material. Apart from voids, kissing bonds for instance, in the form of closed cracks propagating along the interface of the stirred and heat affected zone, are inherent features of the weld and can be considered as one of the main causes of a reduced fatigue life of FSW in comparison to the base material. The main problem with kissing bond defects in FSW, is that they currently are very difficult to detect using existing NDT methods. Besides, in most cases, the defects are not directly accessible from the exposed surface. Therefore, new techniques capable of detecting small kissing bond flaws need to be introduced. In the present paper, a novel and practical approach is introduced based on a nonlinear, single-sided, ultrasonic technique. The proposed inspection technique uses two single element transducers, with the first transducer transmitting an ultrasonic signal that focuses the ultrasonic waves at the bottom side of the sample where cracks are most likely to occur. The large amount of energy at the focus activates the kissing bond, resulting in the generation of nonlinear features in the wave propagation. These nonlinear features are then captured by the second transducer operating in pitch-catch mode, and are analyzed, using pulse inversion, to reveal the presence of a defect. The performance of the proposed nonlinear, pitch-catch technique, is first illustrated using a numerical study of an aluminum sample containing simple, vertically oriented, incipient cracks. Later, the proposed technique is also applied experimentally on a real-life friction stir welded butt joint containing a kissing bond flaw. Copyright © 2016 Elsevier B.V. All rights reserved.
Pearson's Functions to Describe FSW Weld Geometry
NASA Astrophysics Data System (ADS)
Lacombe, D.; Gutierrez-Orrantia, M. E.; Coupard, D.; Tcherniaeff, S.; Girot, F.
2011-01-01
Friction stir welding (FSW) is a relatively new joining technique particularly for aluminium alloys that are difficult to fusion weld. In this study, the geometry of the weld has been investigated and modelled using Pearson's functions. It has been demonstrated that the Pearson's parameters (mean, standard deviation, skewness, kurtosis and geometric constant) can be used to characterize the weld geometry and the tensile strength of the weld assembly. Pearson's parameters and process parameters are strongly correlated allowing to define a control process procedure for FSW assemblies which make radiographic or ultrasonic controls unnecessary. Finally, an optimisation using a Generalized Gradient Method allows to determine the geometry of the weld which maximises the assembly tensile strength.
NASA Technical Reports Server (NTRS)
Ding, Robert J.
2010-01-01
Four advanced welding techniques and their use in NASA are briefly reviewed in this poster presentation. The welding techniques reviewed are: Solid State Welding, Friction Stir Welding (FSW), Thermal Stir Welding (TSW) and Ultrasonic Stir Welding.
Solid State Welding Development at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Ding, Robert J.; Walker, Bryant
2012-01-01
What is TSW and USW? TSW is a solid state weld process consisting of an induction coil heating source, a stir rod, and non-rotating containment plates Independent heating, stirring and forging controls Decouples the heating, stirring and forging process elements of FSW. USW is a solid state weld process consisting of an induction coil heating source, a stir rod, and a non-rotating containment plate; Ultrasonic energy integrated into non-rotating containment plate and stir rod; Independent heating, stirring and forging controls; Decouples the heating, stirring and forging process elements of FSW.
Detection and assessment of flaws in friction stir welded metallic plates
NASA Astrophysics Data System (ADS)
Fakih, Mohammad Ali; Mustapha, Samir; Tarraf, Jaafar; Ayoub, Georges; Hamade, Ramsey
2017-04-01
Investigated is the ability of ultrasonic guided waves to detect flaws and assess the quality of friction stir welds (FSW). AZ31B magnesium plates were friction stir welded. While process parameters of spindle speed and tool feed were fixed, shoulder penetration depth was varied resulting in welds of varying quality. Ultrasonic waves were excited at different frequencies using piezoelectric wafers and the fundamental symmetric (S0) mode was selected to detect the flaws resulting from the welding process. The front of the first transmitted wave signal was used to capture the S0 mode. A damage index (DI) measure was defined based on the amplitude attenuation after wave interaction with the welded zone. Computed Tomography (CT) scanning was employed as a nondestructive testing (NDT) technique to assess the actual weld quality. Derived DI values were plotted against CT-derived flaw volume resulting in a perfectly linear fit. The proposed approach showed high sensitivity of the S0 mode to internal flaws within the weld. As such, this methodology bears great potential as a future predictive method for the evaluation of FSW weld quality.
Nondestructive Evaluation of Friction Stir-Welded Aluminum Alloy to Coated Steel Sheet Lap Joint
NASA Astrophysics Data System (ADS)
Das, H.; Kumar, A.; Rajkumar, K. V.; Saravanan, T.; Jayakumar, T.; Pal, Tapan Kumar
2015-11-01
Dissimilar lap joints of aluminum sheet (AA 6061) of 2 mm thickness and zinc-coated steel sheet of 1 mm thickness were produced by friction stir welding with different combinations of rotational speed and travel speed. Ultrasonic C- and B-scanning, and radiography have been used in a complementary manner for detection of volumetric (cavity and flash) and planar (de bond) defects as the defects are in micron level. Advanced ultrasonic C-scanning did not provide any idea about the defects, whereas B-scanning cross-sectional image showed an exclusive overview of the micron-level defects. A digital x-ray radiography methodology is proposed for quality assessment of the dissimilar welds which provide three-fold increase in signal-to-noise ratio with improved defect detection sensitivity. The present study clearly shows that the weld tool rotational speed and travel speed have a decisive role on the quality of the joints obtained by the friction stir welding process. The suitability of the proposed NDE techniques to evaluate the joint integrity of dissimilar FSW joints is thus established.
Development of Inspection for Friction Stir Welds for Rocket Fuel Tanks
NASA Technical Reports Server (NTRS)
Russell, Samuel S.
2012-01-01
During development of the Ares I weld processes nondestructive and destructive testing were used to identify and characterize defects that occurred. These defects were named and character noted. This catalogue of defects and characteristics was then used to develop inspection methods for Self Reacting Friction Stir Welds (SR ]FSW) and Conventional Friction Stir Welds (C ]FSW). Dye penetrant, eddy current, x ]radiography, single element ultrasonic, and phased array ultrasonic (PAUT) inspection procedures were developed to target the expected defects. Once the method procedure was developed a comparison was performed to allow for selection of the best inspection method. Tests of the effectiveness of the inspection were performed on purposely fabricated flawed specimens and electrodischarge machined notches. The initial test results prompted a revisit of the PAUT procedure and a redesign of the inspection. Subsequent testing showed that a multi ]angle PAUT inspection resulted in better detection capability. A discussion of the most effective orientations of the PAUT transducer will be presented. Also, the implementation of the inspection on production hardware will be presented. In some cases the weld tool is used as the transducer manipulator and in some cases a portable scanner is used
NASA Astrophysics Data System (ADS)
Thomä, M.; Wagner, G.; Straß, B.; Conrad, C.; Wolter, B.; Benfer, S.; Fürbeth, W.
2016-03-01
Due to the steadily increasing demand on innovative manufacturing processes, modern lightweight construction concepts become more and more important. Especially joints of dissimilar metals offer a variety of advantages due to their high potential for lightweight construction. The focus of the investigations was Al/Mg-joints. Friction Stir Welding (FSW) is an efficient process to realize high strength joints between these materials in ductile condition. Furthermore, for a simultaneous transmission of power ultrasound during the FSW-process (US-FSW) a positive effect on the achievable tensile strength of the Al/Mg-joints was proven. In the present work the industrial used die cast alloys EN AC-48000 (AlSi12CuNiMg) and AZ80 (MgAl8Zn) were joined by a machining center modified especially for Ultrasound Supported Friction Stir Welding. The appearing welding zone and the formation of intermetallic phases under the influence of power ultrasound were examined in particular. In order to identify optimal process parameters extensive preliminary process analyzes have been carried out. Following this, an ultrasound-induced more intensive stirring of the joining zone and as a result of this a considerably modified intermetallic zone was detected. At the same time an increase of the tensile strength of about 25% for US-FSW-joints and for fatigue an up to three times higher number of cycles to failure in comparison to a conventional welding process was observed. Moreover, detailed corrosion analyzes have shown that especially the welding zone was influenced by the corrosive attack. To expand and deepen the knowledge of the US-FSW-process further material combinations such as Ti/Steel and Al/Steel will be considered in future.
NASA Astrophysics Data System (ADS)
Fakih, Mohammad Ali; Mustapha, Samir; Tarraf, Jaafar; Ayoub, Georges; Hamade, Ramsey
2018-02-01
Ultrasonic guided waves (GWs), e.g. Lamb waves, have been proven effective in the detection of defects such as corrosion, cracking, delamination, and debonding in both composite and metallic structures. They are a significant tool employed in structural health monitoring. In this study, the ability of ultrasonic GWs to assess the quality of friction stir welding (FSW) was investigated. Four friction stir welded AZ31B magnesium plates processed with different welding parameters and a non-welded plate were used. The fundamental symmetric (S0) Lamb wave mode was excited using piezoelectric wafers (PZTs). Further, the S0 mode was separated using the "Improved complete ensemble empirical mode decomposition with adaptive noise (Improved CEEMDAN)" technique. A damage index (DI) was defined based on the variation in the amplitude of the captured wave signals in order to detect the presence and asses the severity of damage resulting from the welding process. As well, computed tomography (CT) scanning was used as a non-destructive testing (NDT) technique to assess the actual weld quality and validate predictions based on the GW approach. The findings were further confirmed using finite element analysis (FEA). To model the actual damage profile in the welds, "Mimics" software was used for the 3D reconstruction of the CT scans. The built 3D models were later used for evaluation of damage volume and for FEA. The damage volumes were correlated to the damage indices computed from both experimental and numerical data. The proposed approach showed high sensitivity of the S0 mode to internal flaws within the friction stir welded joints. This methodology has great potential as a future classification method of FSW quality.
Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding
NASA Technical Reports Server (NTRS)
Schneider, Judy; Beshears, Ronald; Nunes, Arthur C., Jr.
2005-01-01
In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.
Characterization of Plastic flow and Resulting Micro-Textures in a Friction Stir Weld
NASA Technical Reports Server (NTRS)
Schneider, J. A.; Nunes, A. C., Jr.
2003-01-01
The mechanically affected zone of a friction stir weld (FSW) cross section exhibits two distinct microstructural regions, possibly the residues of two distinct currents of metal in the FSW flow process. In this study the respective textures of these microstructural regions are investigated using orientation image mapping (OIM).
NASA Astrophysics Data System (ADS)
Zhang, Ling; Min, Junying; Wang, Bin; Lin, Jianping; Li, Fangfang; Liu, Jing
2016-03-01
In practical engineering, finite element(FE) modeling for weld seam is commonly simplified by neglecting its inhomogeneous mechanical properties. This will cause a significant loss in accuracy of FE forming analysis, in particular, for friction stir welded(FSW) blanks due to the large width and good formability of its weld seam. The inhomogeneous mechanical properties across weld seam need to be well characterized for an accurate FE analysis. Based on a similar AA5182 FSW blank, the metallographic observation and micro-Vickers hardness analysis upon the weld cross-section are performed to identify the interfaces of different sub-zones, i.e., heat affected zone(HAZ), thermal-mechanically affected zone(TMAZ) and weld nugget(WN). Based on the rule of mixture and hardness distribution, a constitutive model is established for each sub-zone to characterize the inhomogeneous mechanical properties across the weld seam. Uniaxial tensile tests of the AA5182 FSW blank are performed with the aid of digital image correlation(DIC) techniques. Experimental local stress-strain curves are obtained for different weld sub-zones. The experimental results show good agreement with those derived from the constitutive models, which demonstrates the feasibility and accuracy of these models. The proposed research gives an accurate characterization of inhomogeneous mechanical properties across the weld seam produced by FSW, which provides solutions for improving the FE simulation accuracy of FSW sheet forming.
Non Destructive Analysis of Fsw Welds using Ultrasonic Signal Analysis
NASA Astrophysics Data System (ADS)
Pavan Kumar, T.; Prabhakar Reddy, P.
2017-08-01
Friction Stir Welding is an evolving metal joining technique and is mostly used in joining materials which cannot be easily joined by other available welding techniques. It is a technique which can be used for welding dissimilar materials also. The strength of the weld joint is determined by the way in which these material are mixing with each other, since we are not using any filler material for the welding process the intermixing has a significant importance. The complication with the friction stir welding process is that there are many process parameters which effect this intermixing process such as tool geometry, rotating speed of the tool, transverse speed etc., In this study an attempt is made to compare the material flow and weld quality of various weldments by changing the parameters. Ultrasonic signal Analysis is used to characterize the microstructure of the weldments. use of ultrasonic waves is a non destructive, accurate and fast way of characterization of microstructure. In this method the relationship between the ultrasonic measured parameters and microstructures are evaluated using background echo and backscattered signal process techniques. The ultrasonic velocity and attenuation measurements are dependent on the elastic modulus and any change in the microstructure is reflected in the ultrasonic velocity. An insight into material flow is essential to determine the quality of the weld. Hence an attempt is made in this study to know the relationship between tool geometry and the pattern of material flow and resulting weld quality the experiments are conducted to weld dissimilar aluminum alloys and the weldments are characterized using and ultra Sonic signal processing. Characterization is also done using Scanning Electron Microscopy. It is observed that there is a good correlation between the ultrasonic signal processing results and Scanning Electron Microscopy on the observed precipitates. Tensile tests and hardness tests are conducted on the weldments and compared for determining the weld quality.
NASA Technical Reports Server (NTRS)
Roth, Don J.
1996-01-01
This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.
Characterization of the Micro Textures in a Friction Stir Weld
NASA Technical Reports Server (NTRS)
Schneider, Judy; Nunes, Arthur C.
2004-01-01
In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. The Dynamically-Recrystallized-Zone (DXZ) of a polished and etched FSW cross-section exhibits contrasting bands (the "onion-ring" structure), the origins of which are unclear. An orientation image mapping (OIM) study suggests that the corresponding bands may correspond respectively to a "straight-through" current of metal bypassing the pin tool in a single rotation or less and a "maelstrom" current rotating a number of times around the pin tool.
Unified Ultrasonic/Eddy-Current Data Acquisition
NASA Technical Reports Server (NTRS)
Chern, E. James; Butler, David W.
1993-01-01
Imaging station for detecting cracks and flaws in solid materials developed combining both ultrasonic C-scan and eddy-current imaging. Incorporation of both techniques into one system eliminates duplication of computers and of mechanical scanners; unifies acquisition, processing, and storage of data; reduces setup time for repetitious ultrasonic and eddy-current scans; and increases efficiency of system. Same mechanical scanner used to maneuver either ultrasonic or eddy-current probe over specimen and acquire point-by-point data. For ultrasonic scanning, probe linked to ultrasonic pulser/receiver circuit card, while, for eddy-current imaging, probe linked to impedance-analyzer circuit card. Both ultrasonic and eddy-current imaging subsystems share same desktop-computer controller, containing dedicated plug-in circuit boards for each.
Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han
2015-01-01
The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties. PMID:28793720
Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han
2015-12-04
The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties.
Lancaster, Kathryn E; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C; Chadwick, Katy; Powers, Kimberly A; Pence, Brian W; Go, Vivian F; Hoffman, Irving F; Miller, William C
2017-02-01
Female sex workers (FSW) have a high prevalence of substance use and HIV, but the impact of substance use on HIV treatment engagement is not well established. We evaluated the association between alcohol and marijuana use and sub-optimal HIV treatment engagement outcomes among HIV-infected FSW in Lilongwe, Malawi. We enroled FSW using venue-based recruitment into a cross-sectional evaluation assessing substance use and HIV treatment engagement. Seropositive FSW, identified through HIV rapid testing, received rapid CD4 count and viral load testing. We used Poisson regression with robust variance estimates to ascertain associations of alcohol and marijuana use with sub-optimal HIV treatment outcomes: (1) lack of ART use among previously diagnosed, ART-eligible FSW and (2) viral nonsuppression among FSW on ART. Of previously diagnosed, ART-eligible FSW (n = 96), 29% were not using ART. Patterns of hazardous drinking were identified in 30%, harmful drinking in 10%, and alcohol dependence in 12%. ART-eligible FSW with harmful drinking or alcohol dependency were 1.9 (95% CI: 1.0, 3.8) times as likely to not use ART compared to FSW without harmful or dependent drinking. Among those on ART, 14% were virally nonsuppressed. The prevalence ratio for viral nonsuppression was 2.0 (95% CI: 0.6, 6.5) for harmful drinkers and alcohol-dependent FSW. Over 30% of ART-eligible FSW reported using marijuana. Marijuana-using FSW were 1.9 (95% CI: 0.8, 4.6) times as likely to not use ART compared to FSW who were not using marijuana. Given the high prevalence of alcohol use and its association with lack of ART use, ART uptake and alcohol reduction strategies should be tailored for alcohol-using FSW in Malawi.
Lancaster, Kathryn E.; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C.; Chadwick, Katy; Powers, Kimberly A.; Pence, Brian W.; Go, Vivian F.; Hoffman, Irving F.; Miller, William C.
2016-01-01
Female sex workers (FSW) have a high prevalence of substance use and HIV, but the impact of substance use on HIV treatment engagement is not well established. We evaluated the association between alcohol and marijuana use and sub-optimal HIV treatment engagement outcomes among HIV-infected FSW in Lilongwe, Malawi. We enroled FSW using venue-based recruitment into a cross-sectional evaluation assessing substance use and HIV treatment engagement. Seropositive FSW, identified through HIV rapid testing, received rapid CD4 count and viral load testing. We used Poisson regression with robust variance estimates to ascertain associations of alcohol and marijuana use with sub-optimal HIV treatment outcomes: (1) lack of ART use among previously diagnosed, ART-eligible FSW and (2) viral nonsuppression among FSW on ART. Of previously diagnosed, ART-eligible FSW (n = 96), 29% were not using ART. Patterns of hazardous drinking were identified in 30%, harmful drinking in 10%, and alcohol dependence in 12%. ART-eligible FSW with harmful drinking or alcohol dependency were 1.9 (95% CI: 1.0, 3.8) times as likely to not use ART compared to FSW without harmful or dependent drinking. Among those on ART, 14% were virally nonsuppressed. The prevalence ratio for viral nonsuppression was 2.0 (95% CI: 0.6, 6.5) for harmful drinkers and alcohol-dependent FSW. Over 30% of ART-eligible FSW reported using marijuana. Marijuana-using FSW were 1.9 (95% CI: 0.8, 4.6) times as likely to not use ART compared to FSW who were not using marijuana. Given the high prevalence of alcohol use and its association with lack of ART use, ART uptake and alcohol reduction strategies should be tailored for alcohol-using FSW in Malawi. PMID:27442009
Versatile Friction Stir Welding/Friction Plug Welding System
NASA Technical Reports Server (NTRS)
Carter, Robert
2006-01-01
A proposed system of tooling, machinery, and control equipment would be capable of performing any of several friction stir welding (FSW) and friction plug welding (FPW) operations. These operations would include the following: Basic FSW; FSW with automated manipulation of the length of the pin tool in real time [the so-called auto-adjustable pin-tool (APT) capability]; Self-reacting FSW (SRFSW); SR-FSW with APT capability and/or real-time adjustment of the distance between the front and back shoulders; and Friction plug welding (FPW) [more specifically, friction push plug welding] or friction pull plug welding (FPPW) to close out the keyhole of, or to repair, an FSW or SR-FSW weld. Prior FSW and FPW systems have been capable of performing one or two of these operations, but none has thus far been capable of performing all of them. The proposed system would include a common tool that would have APT capability for both basic FSW and SR-FSW. Such a tool was described in Tool for Two Types of Friction Stir Welding (MFS- 31647-1), NASA Tech Briefs, Vol. 30, No. 10 (October 2006), page 70. Going beyond what was reported in the cited previous article, the common tool could be used in conjunction with a plug welding head to perform FPW or FPPW. Alternatively, the plug welding head could be integrated, along with the common tool, into a FSW head that would be capable of all of the aforementioned FSW and FPW operations. Any FSW or FPW operation could be performed under any combination of position and/or force control.
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor); Moerk, Steven (Inventor)
1999-01-01
An imaging system is described which can be used to either passively search for sources of ultrasonics or as an active phase imaging system. which can image fires. gas leaks, or air temperature gradients. This system uses an array of ultrasonic receivers coupled to an ultrasound collector or lens to provide an electronic image of the ultrasound intensity in a selected angular region of space. A system is described which includes a video camera to provide a visual reference to a region being examined for ultrasonic signals.
NASA Astrophysics Data System (ADS)
Hatsukade, Y.; Takahashi, T.; Yasui, T.; Tsubaki, M.; Fukumono, M.; Tanaka, S.
2007-10-01
We have developed an SQUID-NDI technique for evaluation of friction stir welding (FSW) between aluminum alloy A6063 and stainless steel SUS304 from the electric conductivities in board specimens bonded by FSW. A SQUID-NDI system employing an HTS-SQUID gradiometer was constructed to measure current distribution in the FSW specimens by applying voltage to the specimen. By measuring field gradients dBz/dy and dBz/dx above the FSW specimens made with various FSW conditions and then converting them to current vector Jx and Jy, conductivities of FSW areas were estimated. Due to the difference in the FSW conditions, the conductivity distributions varied dramatically. From these results, it was suggested that the conductivities in FSW areas should be varied due to the temperature heated by the friction between the milling tool and the materials.
Complete Status Report Documenting Weld Development for Thin Wall Tubing of ODS Ferritic Alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoelzer, David T.; Edmondson, Philip D.; Gussev, Maxim N.
Beginning in 2015, research in the FCRD program began the development of FSW for joining thin sections of 14YWT in the form of thin (0.5 mm) plate and ultimately thin wall tubing. In the previous fiscal year, a ~1 mm thick plate, or sheet, of 14YWT was produced by hot rolling with no edge cracking. The initial FSW experiment was performed on the 1 mm thick plate and involved a bead-on-plate weld in which the spinning pin tool is plunged into the plate surface, but does not penetrate the thickness of the plate, and then travels the length of themore » plate. The FSW run successfully produced a bead-on-plate stir zone on the 1 mm thick plate of 14YWT, but no characterization studies of the stir zone were performed by the end of FY15. Therefore, the results presented in this report cover the microstructural analysis of the bead-on-plate stir zone and the initial research task on obtaining tensile properties of the stir zone using the digital image correlation (DIC) approach during testing of miniature tensile specimens to assess the quality of the FSW parameters used in the initial experiment. The results of the microstructural characterization study using optical, scanning electron and scanning transmission electron microscopies showed the grain structure in the SZ to have isotropic and irregular shape but very similar size compared to the highly elongated grains oriented horizontally with the plane of the plate that were observed in the unaffected zone of 14YWT. Several cracks oriented horizontally were observed mostly on the retreating side of the SZ in both the SZ and TMAZ. These cracks may have formed due to insufficient pressure being exerted on the top surface of the plate by the shoulder and pin tool during the FSW run. High resolution STEM-EDS analysis showed the presence of the Y-Ti-O particles in the SZ, but that some particles exhibited coarsening. Overall, the FSW parameters used to produce the bead-on-plate SZ in the 0.1 cm thick plate of 14YWT were nearly optimized. The results of the digital image correlation (DIC) analysis of the two SS-Mini-2 tensile specimens fabricated from the 0.1 cm thick plate of 14YWT showed that the specimens exhibited high strength and good ductility. However, strain localization occurred in one of the specimens during the tensile test that was too close to the grips, which invalidated the data from the DIC analysis. This was surprising since the abrupt crack pop-in that occurred in the 0.1 cm thick plate of 14YWT during fabrication by wire EDM suggested that residual stresses were high. Residual stress measurements and the effects of post weld heat treatment on the FSW quality of joined 14YWT plates will be investigated in the next FW work package.« less
The HIV Care Continuum among Female Sex Workers: A Key Population in Lilongwe, Malawi.
Lancaster, Kathryn Elizabeth; Powers, Kimberly A; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C; Chadwick, Katy; Go, Vivian F; Pence, Brian W; Hoffman, Irving F; Miller, William C
2016-01-01
The HIV care continuum among female sex workers (FSW), a key population, has not been well characterized, especially within the generalized epidemics of sub-Saharan Africa. This was the first study to characterize the HIV care continuum among FSW in Lilongwe, Malawi. From July through September 2014, we used venue-based sampling to enroll 200 adult FSW in Lilongwe, Malawi into a cross-sectional evaluation assessing HIV care continuum outcomes. Seropositive FSW, identified using HIV rapid testing, received rapid CD4 counts in addition to viral loads using dried blood spots. We calculated proportions of HIV-infected FSW who had history of care, were on ART, and had suppressed viral load and we used Poisson regression to estimate the associations of demographic characteristics and transmission risk behaviors with each outcome. HIV seroprevalence was 69% (n = 138). Among all FSW the median age was 24 years (IQR: 22-28). Among the 20% who were newly diagnosed and reported previously testing negative, the median time since last HIV test was 11 months (interquartile range: 3-17). The majority (69%) of HIV-infected FSW had a history of HIV care, 52% reported current ART use, and 45% were virally suppressed. Of the FSW who reported current ART use, 86% were virally suppressed. Transmission risk behaviors were not associated with continuum outcomes. FSW in Lilongwe were predominately young and have a high HIV prevalence. Only half of HIV-infected FSW reported current ART use, but the majority of those on ART were virally suppressed. To reduce ongoing transmission and improve health outcomes, increased HIV testing, care engagement, and ART coverage is urgently needed among FSW. Universal testing and treatment strategies for all FSW in Malawi must be strongly considered.
The HIV Care Continuum among Female Sex Workers: A Key Population in Lilongwe, Malawi
Lancaster, Kathryn Elizabeth; Powers, Kimberly A.; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C.; Chadwick, Katy; Go, Vivian F.; Pence, Brian W.; Hoffman, Irving F.; Miller, William C.
2016-01-01
Objective The HIV care continuum among female sex workers (FSW), a key population, has not been well characterized, especially within the generalized epidemics of sub-Saharan Africa. This was the first study to characterize the HIV care continuum among FSW in Lilongwe, Malawi. Methods From July through September 2014, we used venue-based sampling to enroll 200 adult FSW in Lilongwe, Malawi into a cross-sectional evaluation assessing HIV care continuum outcomes. Seropositive FSW, identified using HIV rapid testing, received rapid CD4 counts in addition to viral loads using dried blood spots. We calculated proportions of HIV-infected FSW who had history of care, were on ART, and had suppressed viral load and we used Poisson regression to estimate the associations of demographic characteristics and transmission risk behaviors with each outcome. Results HIV seroprevalence was 69% (n = 138). Among all FSW the median age was 24 years (IQR: 22–28). Among the 20% who were newly diagnosed and reported previously testing negative, the median time since last HIV test was 11 months (interquartile range: 3–17). The majority (69%) of HIV-infected FSW had a history of HIV care, 52% reported current ART use, and 45% were virally suppressed. Of the FSW who reported current ART use, 86% were virally suppressed. Transmission risk behaviors were not associated with continuum outcomes. Conclusions FSW in Lilongwe were predominately young and have a high HIV prevalence. Only half of HIV-infected FSW reported current ART use, but the majority of those on ART were virally suppressed. To reduce ongoing transmission and improve health outcomes, increased HIV testing, care engagement, and ART coverage is urgently needed among FSW. Universal testing and treatment strategies for all FSW in Malawi must be strongly considered. PMID:26808043
Second COS FUV Lifetime Position: FUV Target Acquisition Parameter Update {FENA4}
NASA Astrophysics Data System (ADS)
Penton, Steven
2011-10-01
Verify the ability of the Cycle 20 COS FSW to place an isolated point source at the center of the PSA, using FUV dispersed light target acquisition {TA} from the object and all three FUV gratings at the Second Lifetime Position {SLP}. This program is modeled from the activity summary of FENA4.This program should be executed after the new HV, XD spectral positions, and focus are determined and updated. In addition, the LIFETIME=ALTERNATE TA FSW parameters should be updated prior to execution of this program.NUV imaging TAs have previously been used to determine the correct locations for FUV spectra. We follow the same procedure here.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Yong Chae; Sanderson, Samuel; Mahoney, Murray
Friction stir welding (FSW) has recently attracted attention as an alternative construction process for gas/oil transportation applications due to advantages compared to fusion welding techniques. A significant advantage is the ability of FSW to weld the entire or nearly the entire wall thickness in a single pass, while fusion welding requires multiple passes. However, when FSW is applied to a pipe or tube geometry, an internal back support anvil is required to resist the plunging forces exerted during FSW. Unfortunately, it may not be convenient or economical to use internal backing support due to limited access for some applications. Tomore » overcome this issue, ExxonMobil recently developed a new concept, combining root arc welding and FSW. That is, a root arc weld is made prior to FSW that supports the normal loads associated with FSW. In the present work, mechanical properties of a FSW + root arc welded pipe steel are reported including microstructure and microhardness.« less
Design of embedded endoscopic ultrasonic imaging system
NASA Astrophysics Data System (ADS)
Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin
2008-12-01
Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not only clearly show 511×511 pixels ultrasonic echo images through application program, but also provide a simple and friendly operating interface with mouse and touch screen which is more convenient than the traditional endoscopic ultrasonic imaging system. Including core and peripheral circuits of FPGA and ARM, power network circuit and LCD display circuit, we designed the whole embedded system, achieving the desired purpose by implementing ultrasonic image display properly after the experimental verification, solving the problem of hugeness and complexity of the traditional endoscopic ultrasonic imaging system.
High-Powered, Ultrasonically Assisted Thermal Stir Welding
NASA Technical Reports Server (NTRS)
Ding, Robert
2013-01-01
This method is a solid-state weld process capable of joining metallic alloys without melting. The weld workpieces to be joined by thermal stir welding (TSW) are drawn, by heavy forces, between containment plates past the TSW stir tool that then causes joining of the weld workpiece. TSW is similar to friction stir welding (FSW) in that material is heated into a plastic state (not melted) and stirred using a stir rod. The FSW pin tool is an integrated geometrical structure consisting of a large-diameter shoulder, and a smaller-diameter stir pin protruding from the shoulder. When the pin is plunged into a weld workpiece, the shoulder spins on the surface of the weld workpiece, thus inducing frictional heat into the part. The pin stirs the fraying surfaces of the weld joint, thus joining the weld workpiece into one structure. The shoulder and stir pin of the FSW pin tool must rotate together at a desired rotational speed. The induced frictional energy control and stir pin control of the pin tool cannot be de-coupled. The two work as one integrated unit. TSW, on the other hand, de-couples the heating and stirring of FSW, and allows for independent control of each process element. A uniquely designed induction coil heats the weld workpiece to a desired temperature, and once heated, the part moves into a stir rod whose RPM is also independently controlled. As the weld workpiece moves into the stir rod, the piece is positioned, or sandwiched, between upper and lower containment plates. The plate squeezes together, thus compressing the upper and lower surfaces of the weld workpiece. This compressive force, also called consolidation force, consolidates the plastic material within the weld nugget material as it is being stirred by the stir rod. The stir rod is positioned through the center of the top containment plate and protrudes midway through the opposite lower containment plate where it is mechanically captured. The upper and lower containment plates are separated by a distance equal to the thickness of the material being welded. The TSW process can be significantly improved by reducing the draw forces. This can be achieved by reducing the friction forces between the weld workpieces and the containment plates. High-power ultrasonic (HPU) vibrations of the containment plates achieve friction reduction in the TSW process. Furthermore, integration of the HPU energy into the TSW stir rod can increase tool life of the stir rod, and can reduce shear forces to which the stir rod is subjected during the welding process. TSW has been used to successfully join 0.500-in (˜13-mm) thick commercially pure (CP) titanium, titanium 6AL- 4V, and titanium 6AL-4V ELI in weld joint lengths up to 9 ft (˜2.75-m) long. In addition, the TSW process was used to fabricate a sub-scale hexagonally shaped gun turret component for the U.S. Navy. The turret is comprised of six 0.5000-in (˜13-mm) thick angled welds. Each angled weld joint was prepared by machining the mating surfaces to 120deg. The angled weld joint was then fixtured using an upper and lower containment plate of the same geometry of the angled weld joint. The weld joint was then stirred by the stir rod as it and the upper and lower containment plates traverse through the angled joint prep.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jingyi; Upadhyay, Piyush; Hovanski, Yuri
Friction-stir-welding (FSW) is a cost-effective and high quality joining process for aluminum alloys (especially heat-treatable allo ys) that has been applied successfully in the aerospace industry. However, the full potential of FSW on more cost-sensitive applications is still limited by the production rate, namely the welding speed of the process. The majority of literature evaluating FSW of aluminum alloys is based on welds made in the range of welding speeds around hundreds of millimeters per minute, and only a handful are at a moderate speed of 1 m/min. In this study we present a microstructural analysis of friction stir weldedmore » AA7075-T6 blanks with welding speeds up to 3 m/min. Textures, microstructures, mechanical properties, and weld quality are analyzed using TEM, EBSD, metallographic imaging, and Vickers hardness. Results are coupled with welding parameters to aid in the understanding of the complex material flow and texture gradients within the welds in an effort to optimize welding parameters for high speed processing.« less
Visual Target Tracking on the Mars Exploration Rovers
NASA Technical Reports Server (NTRS)
Kim, Won S.; Biesiadecki, Jeffrey J.; Ali, Khaled S.
2008-01-01
Visual Target Tracking (VTT) has been implemented in the new Mars Exploration Rover (MER) Flight Software (FSW) R9.2 release, which is now running on both Spirit and Opportunity rovers. Applying the normalized cross-correlation (NCC) algorithm with template image magnification and roll compensation on MER Navcam images, VTT tracks the target and enables the rover to approach the target within a few cm over a 10 m traverse. Each VTT update takes 1/2 to 1 minute on the rovers, 2-3 times faster than one Visual Odometry (Visodom) update. VTT is a key element to achieve a target approach and instrument placement over a 10-m run in a single sol in contrast to the original baseline of 3 sols. VTT has been integrated into the MER FSW so that it can operate with any combination of blind driving, Autonomous Navigation (Autonav) with hazard avoidance, and Visodom. VTT can either guide the rover towards the target or simply image the target as the rover drives by. Three recent VTT operational checkouts on Opportunity were all successful, tracking the selected target reliably within a few pixels.
21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic...
Acoustic imaging with time reversal methods: From medicine to NDT
NASA Astrophysics Data System (ADS)
Fink, Mathias
2015-03-01
This talk will present an overview of the research conducted on ultrasonic time-reversal methods applied to biomedical imaging and to non-destructive testing. We will first describe iterative time-reversal techniques that allow both focusing ultrasonic waves on reflectors in tissues (kidney stones, micro-calcifications, contrast agents) or on flaws in solid materials. We will also show that time-reversal focusing does not need the presence of bright reflectors but it can be achieved only from the speckle noise generated by random distributions of non-resolved scatterers. We will describe the applications of this concept to correct distortions and aberrations in ultrasonic imaging and in NDT. In the second part of the talk we will describe the concept of time-reversal processors to get ultrafast ultrasonic images with typical frame rates of order of 10.000 F/s. It is the field of ultrafast ultrasonic imaging that has plenty medical applications and can be of great interest in NDT. We will describe some applications in the biomedical domain: Quantitative Elasticity imaging of tissues by following shear wave propagation to improve cancer detection and Ultrafast Doppler imaging that allows ultrasonic functional imaging.
NASA Technical Reports Server (NTRS)
Horton, Karla Renee
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. This work reports on material properties and strain patterns developed in a SR-FSW with a friction plug weld. Specifically, this study examines the behavior of a SR-FSW formed between an AA 2014-T6 plate on the advancing side and an AA 2219-T87 plate on the retreating side and a SR-FSW (AA 2014-T6 to AA 2219-T87) with a 2219-T87 plug weld. This study presents the results of a characterization of the micro-hardness, joint strength, and strain field characterization of SR-FSW and FPW joints tested at room temperature and cryogenic temperatures.
GPU Accelerated Ultrasonic Tomography Using Propagation and Back Propagation Method
2015-09-28
the medical imaging field using GPUs has been done for many years. In [1], Copeland et al. used 2D images , obtained by X - ray projections, to...Index Terms— Medical Imaging , Ultrasonic Tomography, GPU, CUDA, Parallel Computing I. INTRODUCTION GRAPHIC Processing Units (GPUs) are computation... Imaging Algorithm The process of reconstructing images from ultrasonic infor- mation starts with the following acoustical wave equation: ∂2 ∂t2 u ( x
The application of coded excitation technology in medical ultrasonic Doppler imaging
NASA Astrophysics Data System (ADS)
Li, Weifeng; Chen, Xiaodong; Bao, Jing; Yu, Daoyin
2008-03-01
Medical ultrasonic Doppler imaging is one of the most important domains of modern medical imaging technology. The application of coded excitation technology in medical ultrasonic Doppler imaging system has the potential of higher SNR and deeper penetration depth than conventional pulse-echo imaging system, it also improves the image quality, and enhances the sensitivity of feeble signal, furthermore, proper coded excitation is beneficial to received spectrum of Doppler signal. Firstly, this paper analyzes the application of coded excitation technology in medical ultrasonic Doppler imaging system abstractly, showing the advantage and bright future of coded excitation technology, then introduces the principle and the theory of coded excitation. Secondly, we compare some coded serials (including Chirp and fake Chirp signal, Barker codes, Golay's complementary serial, M-sequence, etc). Considering Mainlobe Width, Range Sidelobe Level, Signal-to-Noise Ratio and sensitivity of Doppler signal, we choose Barker codes as coded serial. At last, we design the coded excitation circuit. The result in B-mode imaging and Doppler flow measurement coincided with our expectation, which incarnated the advantage of application of coded excitation technology in Digital Medical Ultrasonic Doppler Endoscope Imaging System.
NASA Technical Reports Server (NTRS)
1995-01-01
Sonix, Inc., of Springfield, Virginia, has implemented ultrasonic imaging methods developed at the NASA Lewis Research Center. These methods have heretofore been unavailable on commercial ultrasonic imaging systems and provide significantly more sensitive material characterization than conventional high-resolution ultrasonic c-scanning. The technology transfer is being implemented under a cooperative agreement between NASA and Sonix, and several invention disclosures have been submitted by Dr. Roth to protect Lewis interests. Sonix has developed ultrasonic imaging systems used worldwide for microelectronics, materials research, and commercial nondestructive evaluation (NDE). In 1993, Sonix won the U.S. Department of Commerce "Excellence in Exporting" award. Lewis chose to work with Sonix for two main reasons: (1) Sonix is an innovative leader in ultrasonic imaging systems, and (2) Sonix was willing to apply the improvements we developed with our in-house Sonix equipment. This symbiotic joint effort has produced mutual benefits. Sonix recognized the market potential of our new and highly sensitive methods for ultrasonic assessment of material quality. We, in turn, see the cooperative effort as an effective means for transferring our technology while helping to improve the product of a domestic firm.
Subsurface imaging of grain microstructure using picosecond ultrasonics
Khafizov, M.; Pakarinen, J.; He, L.; ...
2016-04-21
We report on imaging subsurface grain microstructure using picosecond ultrasonics. This approach relies on elastic anisotropy of crystalline materials where ultrasonic velocity depends on propagation direction relative to the crystal axes. Picosecond duration ultrasonic pulses are generated and detected using ultrashort light pulses. In materials that are transparent or semitransparent to the probe wavelength, the probe monitors GHz Brillouin oscillations. The frequency of these oscillations is related to the ultrasonic velocity and the optical index of refraction. Ultrasonic waves propagating across a grain boundary experience a change in velocity due to a change in crystallographic orientation relative to the ultrasonicmore » propagation direction. This change in velocity is manifested as a change in the Brillouin oscillation frequency. Using the ultrasonic propagation velocity, the depth of the interface can be determined from the location in time of the transition in oscillation frequency. An image of the grain boundary is obtained by scanning the beam along the surface. We demonstrate this volumetric imaging capability using a polycrystalline UO 2 sample. As a result, cross section liftout analysis of the grain boundaries using electron microscopy were used to verify our imaging results.« less
Magnani, Robert; Riono, Pandu; Nurhayati; Saputro, Eko; Mustikawati, Dyah; Anartati, Atiek; Prabawanti, Ciptasari; Majid, Nurholis; Morineau, Guy
2010-10-01
To assess the HIV/AIDS epidemic situation among female sex workers (FSW) in Indonesia using data from the 2007 Integrated Biological-Behavioural Surveillance (IBBS). Behavioural data were collected from time-location samples of 5947 FSW in 10 cities in late 2007. HIV, syphilis, gonorrhoea and chlamydia test results were obtained for 4396, 4324, 3291 and 3316 FSW, respectively. Trends in HIV prevalence were assessed via linkage with sentinel surveillance data. Factors associated with HIV, gonorrhoea and chlamydia infection were assessed using multivariable logistic regression. HIV prevalence averaged 10.5% among direct and 4.9% among indirect FSW, and had increased steadily among direct FSW from 2002 to 2007. Prevalence of chlamydia, gonorrhoea and active syphilis averaged 35.6%, 31.8% and 7.3%, respectively, among direct FSW, and 28.7%, 14.3% and 3.5% among indirect FSW. Being a direct FSW, younger age and having current infection with syphilis and gonorrhoea and/or chlamydia were associated with a higher likelihood of HIV infection. Number of clients in the past week and consumption of alcohol before having sex were associated with a higher likelihood of gonorrhoea and/or chlamydia infection, while having received a STI clinic check-up in the previous 3 months and/or periodic presumptive treatment for sexually transmitted infections (STIs) in the past 6 months were associated with reduced likelihood of infection. The HIV/AIDS epidemic among FSW in Indonesia appears to be expanding, albeit unevenly across provinces and types of FSW. High STI prevalence is conducive to further expansion, but recent efforts to strengthen STI control appear promising.
Qian, Liu; Zhuang, Kongshao; Henderson, Gail E.; Shenglong, Quzhen; Fang, Jingwen; Yao, Huiqin; Qin, Jingxin; Yang, Yanzhen; Abler, Laurie
2013-01-01
Prior research on female sex workers (FSW) in China, and their risk for HIV and STI, neglects the nuanced experiences of ethnic minority FSW. We conducted participant observations and in-depth interviews with 33 FSW and six venue bosses to describe the experiences of FSW and management structures in high and low-priced sex work venues in Liuzhou, China. In low-priced venues, FSW had more autonomy and stronger relationships with their ethnic minority peers. Mid and high-priced venues had more formal management structures. Ethnic minority FSW working in higher priced venues experienced less support and kinship with their peers. HIV/STI prevention outreach activities occurred in all of the venues, but they were not tailored for different venue types or for ethnic minority FSW. Our findings provide guidance for tailoring public health programs that meet the needs of ethnic minority women working in different types of sex work venues. PMID:23912337
Liu, Qian; Zhuang, Kongshao; Henderson, Gail E; Shenglong, Quzhen; Fang, Jingwen; Yao, Huiqin; Qin, Jingxin; Yang, Yanzhen; Abler, Laurie
2014-02-01
Prior research on female sex workers (FSW) in China, and their risk for HIV and STI, neglects the nuanced experiences of ethnic minority FSW. We conducted participant observations and in-depth interviews with 33 FSW and six venue bosses to describe the experiences of FSW and management structures in low and high-priced sex work venues in Liuzhou, China. In low-priced venues, FSW had more autonomy and stronger relationships with their ethnic minority peers. Mid- and high-priced venues had more formal management structures. Ethnic minority FSW working in higher priced venues experienced less support and kinship with their peers. HIV/STI prevention outreach activities occurred in all of the venues, but they were not tailored for different venue types or for ethnic minority FSW. Our findings provide guidance for tailoring public health programs that meet the needs of ethnic minority women working in different types of sex work venues.
MacLean, Sarah A; Lancaster, Kathryn E; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C; Pence, Brian W; Gaynes, Bradley N; Hoffman, Irving F; Miller, William C
2018-02-01
Globally, female sex workers (FSW) experience a high prevalence of mental health disorders, but in sub-Saharan Africa these are rarely identified. If left untreated, mental health disorders may place FSW and their partners at risk for HIV/sexually transmitted infections (STIs). We assessed the prevalence and correlates of probable depression, post-traumatic stress disorder (PTSD), and suicidal ideation (SI) in a cohort of 200 FSW in Lilongwe, Malawi. FSW completed the Patient Health Questionnaire-9 and the PTSD Check List-Civilian Version. The prevalence of depression was 8%, as was the prevalence of PTSD. Nearly half (49%) of FSW were experiencing mild depression. FSW were more likely to have probable depression if they completed primary school or initiated sex work before 18 years. They were more likely to have probable PTSD if they had ≥ 20 clients per week or initiated sex work before 18 years. Interventions are needed to diagnose mental health disorders among FSW at great risk for HIV/STIs.
NASA Astrophysics Data System (ADS)
Hasegawa, Hideyuki
2017-07-01
The range spatial resolution is an important factor determining the image quality in ultrasonic imaging. The range spatial resolution in ultrasonic imaging depends on the ultrasonic pulse length, which is determined by the mechanical response of the piezoelectric element in an ultrasonic probe. To improve the range spatial resolution without replacing the transducer element, in the present study, methods based on maximum likelihood (ML) estimation and multiple signal classification (MUSIC) were proposed. The proposed methods were applied to echo signals received by individual transducer elements in an ultrasonic probe. The basic experimental results showed that the axial half maximum of the echo from a string phantom was improved from 0.21 mm (conventional method) to 0.086 mm (ML) and 0.094 mm (MUSIC).
Friction Stir Welding: Standards and Specifications in Today's U.S. Manufacturing and Fabrication
NASA Technical Reports Server (NTRS)
Ding, Robert Jeffrey
2008-01-01
New welding and technology advancements are reflected in the friction stir welding (FSW) specifications used in the manufacturing sector. A lack of publicly available specifications as one of the reasons that the FSW process has not propagate through the manufacturing sectors. FSW specifications are an integral supporting document to the legal agreement written between two entities for deliverable items. Understanding the process and supporting specifications is essential for a successful FSW manufacturing operation. This viewgraph presentation provides an overview of current FSW standards in the industry and discusses elements common to weld specifications.
Cassini Attitude Control Flight Software: from Development to In-Flight Operation
NASA Technical Reports Server (NTRS)
Brown, Jay
2008-01-01
The Cassini Attitude and Articulation Control Subsystem (AACS) Flight Software (FSW) has achieved its intended design goals by successfully guiding and controlling the Cassini-Huygens planetary mission to Saturn and its moons. This paper describes an overview of AACS FSW details from early design, development, implementation, and test to its fruition of operating and maintaining spacecraft control over an eleven year prime mission. Starting from phases of FSW development, topics expand to FSW development methodology, achievements utilizing in-flight autonomy, and summarize lessons learned during flight operations which can be useful to FSW in current and future spacecraft missions.
NDE application of ultrasonic tomography to a full-scale concrete structure.
Choi, Hajin; Popovics, John S
2015-06-01
Newly developed ultrasonic imaging technology for large concrete elements, based on tomographic reconstruction, is presented. The developed 3-D internal images (velocity tomograms) are used to detect internal defects (polystyrene foam and pre-cracked concrete prisms) that represent structural damage within a large steel reinforced concrete element. A hybrid air-coupled/contact transducer system is deployed. Electrostatic air-coupled transducers are used to generate ultrasonic energy and contact accelerometers are attached on the opposing side of the concrete element to detect the ultrasonic pulses. The developed hybrid testing setup enables collection of a large amount of high-quality, through-thickness ultrasonic data without surface preparation to the concrete. The algebraic reconstruction technique is used to reconstruct p-wave velocity tomograms from the obtained time signal data. A comparison with a one-sided ultrasonic imaging method is presented for the same specimen. Through-thickness tomography shows some benefit over one-sided imaging for highly reinforced concrete elements. The results demonstrate that the proposed through-thickness ultrasonic technique shows great potential for evaluation of full-scale concrete structures in the field.
NASA Astrophysics Data System (ADS)
Kumar, K. S. Anil; Murigendrappa, S. M.; Kumar, Hemantha; Shekhar, Himanshu
2018-04-01
Friction stir welding (FSW) dissimilar joints of aluminium alloys of 2024-T351 and 7075-T651 were produced by reinforcing silicon carbide nano particle (SiCNP) in the rectangular cut groove made on the adjoining surface of the two dissimilar alloy plates joined in the butt configuration. A FSW tool of taper threaded cylindrical shape is used for producing the FSW dissimilar joints reinforced with SiCNP in the weld nugget zone (WNZ) and to produce metal matrix nano composite (MMNC) at the WNZ. In the experimental investigation, the constant FSW tool traverse speed of 40 mm/min and tool plunge depth of 6.2 mm/min is kept as constant, while the FSW tool rotation speed was varied from 400 rpm to 1800 rpm. The effect continuous varying tool rotation speed range from 400 rpm to 1800 rpm along the weld length and on the distribution of SiCNP in WNZ is analysed by conducting macro and microstructure study using optical microscopy (OM) and scanning electron microscopy (SEM) provided with energy dispersive spectrometry (EDS). In the experimental investigation, the combination of continuous varying FSW tool rotation speed range from 900rpm to 1150 rpm, constant tool traverse speed range 40 mm/min and tool plunge depth of 6.2 mm results in defect free, proper distribution of SiCNP and highest tensile properties for the FSW dissimilar joints. The highest ultimate tensile strength (UTS) of 380 MPa and yield strength (YS) of 150 MPa was observed for the combination of FSW tool rotation speed of 1000 rpm and tool traverse speed of 40 mm/min. The increasing in FSW tool rotation speed above 1250 rpm results in non homogeneous distribution of SiCNP in WNZ, excessive flash in the weld crown area and shows decreasing tendency in the tensile properties of the FSW dissimilar weld joints produced with reinforcing the SiCNP in the WNZ.
Ultrasound-aided high-resolution biophotonic imaging
NASA Astrophysics Data System (ADS)
Wang, Lihong V.
2003-10-01
We develop novel biophotonic imaging for early-cancer detection, a grand challenge in cancer research, using nonionizing electromagnetic and ultrasonic waves. Unlike ionizing x-ray radiation, nonionizing electromagnetic waves such as optical waves are safe for biomedical applications and reveal new contrast mechanisms and functional information. For example, our spectroscopic oblique-incidence reflectometry can detect skin cancers based on functional hemoglobin parameters and cell nuclear size with 95% accuracy. Unfortunately, electromagnetic waves in the nonionizing spectral region do not penetrate biological tissue in straight paths as do x-rays. Consequently, high-resolution tomography based on nonionizing electromagnetic waves alone, as demonstrated by our Mueller optical coherence tomography, is limited to superficial tissue imaging. Ultrasonic imaging, on the contrary, furnishes good imaging resolution but has poor contrast in early-stage tumors and has strong speckle artifacts as well. We developed ultrasound-mediated imaging modalities by combining electromagnetic and ultrasonic waves synergistically. The hybrid modalities yield speckle-free electromagnetic-contrast at ultrasonic resolution in relatively large biological tissue. In ultrasound-modulated (acousto)-optical tomography, a focused ultrasonic wave encodes diffuse laser light in scattering biological tissue. In photo-acoustic (thermo-acoustic) tomography, a low-energy laser (RF) pulse induces ultrasonic waves in biological tissue due to thermoelastic expansion.
Estimates of the number of female sex workers in different regions of the world
Vandepitte, J; Lyerla, R; Dallabetta, G; Crabbé, F; Alary, M; Buvé, A
2006-01-01
Objectives To collect estimated numbers of female sex workers (FSW) and present proportions of FSW in the female population (FSW prevalence) in different regions of the world. Methods Subnational and national estimated numbers of FSW reported in published and unpublished literature, as well as from field investigators involved in research or interventions targeted at FSW, were collected. The proportion of FSW in the adult female population was calculated. Subnational estimates were extrapolated to national estimates if appropriate. Population surveys were scanned for proportions of adult women having sex in exchange for money or goods. Results In sub‐Saharan Africa, the FSW prevalence in the capitals ranged between 0.7% and 4.3% and in other urban areas between 0.4% and 4.3%. Population surveys from this same region yielded even higher proportions of women involved in transactional sex. The national FSW prevalence in Asia ranged between 0.2% and 2.6%; in the ex‐Russian Federation between 0.1% and 1.5%; in East Europe between 0.4% and 1.4%; in West Europe between 0.1% and 1.4%; and in Latin America between 0.2% and 7.4%. Estimates from rural areas were only available from one country. Conclusions Although it is well known and accepted that FSW are a highly vulnerable group in the scope of the HIV epidemic, most countries in the world do not know the size of this population group. The estimates of the prevalence of FSW presented in this paper show how important this hard‐to‐reach population group is in all parts of the world. PMID:16735288
Ramesh, Banadakoppa M; Moses, Stephen; Washington, Reynold; Isac, Shajy; Mohapatra, Bidhubhushan; Mahagaonkar, Sangameshwar B; Adhikary, Rajatashuvra; Brahmam, Ginnela N V; Paranjape, Ramesh S; Subramanian, Thilakavathi; Blanchard, James F
2008-12-01
In four states in southern India we explored the determinants of HIV prevalence among female sex workers (FSW), as well as factors associated with district-level variations in HIV prevalence among FSW. Data from cross-sectional surveys in 23 districts were analysed, with HIV prevalence as the outcome variable, and sociodemographic and sex work characteristics as predictor variables. Multilevel logistic regression was applied to identify factors that could explain variations in HIV prevalence among districts. HIV prevalence among the 10 096 FSW surveyed was 14.5% (95% confidence interval 14.0-15.4), with a large interdistrict variation, ranging from 2% to 38%. Current marital status and the usual place of solicitation emerged as important factors that determine individual probability of being HIV positive, as well as the HIV prevalence within districts. In multivariate analysis, compared with home-based FSW, the odds of being HIV positive was greater for brothel-based FSW [adjusted odds ratio (AOR) 2.17, P
Immigration status and HIV-risk related behaviors among female sex workers in South America.
Bautista, Christian T; Mosquera, Carlos; Serra, Margarita; Gianella, Alberto; Avila, Maria M; Laguna-Torres, Victor; Carr, Jean K; Montano, Silvia M; Sanchez, José L
2008-03-01
This study compares immigrant (i.e., foreigner) with non-immigrant (i.e., local/native) HIV-related risk behaviors among female sex workers (FSW) in South America. A total of 1,845 FSW were enrolled in Argentina, Bolivia, Ecuador, and Uruguay. According to their nationality, 10.1% of participants were immigrant FSW. Immigrant FSW were more likely to be younger in Argentina; to work in a disco/bar in Bolivia; to be single and use illegal drugs in Ecuador; and to work in a brothel, consume alcohol, and have sex with foreign clients in Uruguay. HIV-related sexual and drug use behaviors were more common among immigrant FSW in Bolivia, Ecuador, and Uruguay. Country-specific HIV/STI prevention and control programs should be developed for immigrant FSW populations in South America.
Analysis and design of friction stir welding tool
NASA Astrophysics Data System (ADS)
Jagadeesha, C. B.
2016-12-01
Since its inception no one has done analysis and design of FSW tool. Initial dimensions of FSW tool are decided by educated guess. Optimum stresses on tool pin have been determined at optimized parameters for bead on plate welding on AZ31B-O Mg alloy plate. Fatigue analysis showed that the chosen FSW tool for the welding experiment has not ∞ life and it has determined that the life of FSW tool is 2.66×105 cycles or revolutions. So one can conclude that any arbitrarily decided FSW tool generally has finite life and cannot be used for ∞ life. In general, one can determine the suitability of tool and its material to be used in FSW of the given workpiece materials in advance by this analysis in terms of fatigue life of the tool.
Friction Stir Welding Development at NASA-Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Bhat, Biliyar N.; Carter, Robert W.; Ding, Robert J.; Lawless, Kirby G.; Nunes, Arthur C., Jr.; Russell, Carolyn K.; Shah, Sandeep R.
2001-01-01
This paper presents an overview of friction stir welding (FSW) process development and applications at Marshall Space Flight Center (MSFC). FSW process development started as a laboratory curiosity but soon found support from many users. The FSW process advanced very quickly and has found many applications both within and outside the aerospace industry. It is currently being adapted for joining key elements of the Space Shuttle External Tank for improved producibility and reliability. FSW process modeling is done to better understand and improve the process. Special tools have been developed to weld variable thickness materials including thin and thick materials. FSW is now being applied to higher temperature materials such as copper and to advanced materials such as metal matrix composites. FSW technology is being successfully transferred from MSFC laboratory to shop floors of many commercial companies.
Eccles, Claire; Clarke, Janette
2014-02-01
To assess the proportion of independent indoor female sex workers (FSW) in West Yorkshire, UK who advertise unprotected sex, and to investigate any association with cost, location and provision of anal sex. Data on whether independent indoor FSW (defined as those not advertising via an escort agency or through a parlour) advertised unprotected sexual services, along with demographic data, were collected from 462 advertisement profiles of FSW in West Yorkshire from the website http://www.adultwork.com. Independent t test and χ(2) statistics were used to test the association between advertised unprotected vaginal and oral sex, and FSW age, cost of services, location and whether they advertised anal sex. Unprotected vaginal sex was advertised by 8% of FSW, and unprotected oral sex by 74% of FSW. FSW advertising unprotected vaginal sex were more likely to live in Wakefield and Bradford than in Leeds, had significantly lower hourly rates, and were more likely to advertise anal sex. Advertised condom use for vaginal and oral sex by independent indoor FSW in West Yorkshire was significantly lower than reported rates of protected sex found in previous studies based in London and the south of England. The advertisement of unprotected vaginal sex is associated with factors such as lower hourly rates and the advertisement of higher risk anal sex, which may signify greater economic need. FSW offering unprotected sex therefore represent an at-risk target group for health promotion.
Ultrasonic Imaging Techniques for Breast Cancer Detection
NASA Astrophysics Data System (ADS)
Goulding, N. R.; Marquez, J. D.; Prewett, E. M.; Claytor, T. N.; Nadler, B. R.
2008-02-01
Improving the resolution and specificity of current ultrasonic imaging technology is needed to enhance its relevance to breast cancer detection. A novel ultrasonic imaging reconstruction method is described that exploits classical straight-ray migration. This novel method improves signal processing for better image resolution and uses novel staging hardware options using a pulse-echo approach. A breast phantom with various inclusions is imaged using the classical migration method and is compared to standard computed tomography (CT) scans. These innovative ultrasonic methods incorporate ultrasound data acquisition, beam profile characterization, and image reconstruction. For an ultrasonic frequency of 2.25 MHz, imaged inclusions of approximately 1 cm are resolved and identified. Better resolution is expected with minor modifications. Improved image quality and resolution enables earlier detection and more accurate diagnoses of tumors thus reducing the number of biopsies performed, increasing treatment options, and lowering remission percentages. Using these new techniques the inclusions in the phantom are resolved and compared to the results of standard methods. Refinement of this application using other imaging techniques such as time-reversal mirrors (TRM), synthetic aperture focusing technique (SAFT), decomposition of the time reversal operator (DORT), and factorization methods is also discussed.
NASA Technical Reports Server (NTRS)
Shell, Elaine M.; Lue, Yvonne; Chu, Martha I.
1999-01-01
Flight software (FSW) is a mission critical element of spacecraft functionality and performance. When ground operations personnel interface to a spacecraft, they are dealing almost entirely with onboard software. This software, even more than ground/flight communications systems, is expected to perform perfectly at all times during all phases of on-orbit mission life. Due to the fact that FSW can be reconfigured and reprogrammed to accommodate new spacecraft conditions, the on-orbit FSW maintenance team is usually significantly responsible for the long-term success of a science mission. Failure of FSW can result in very expensive operations work-around costs and lost science opportunities. There are three basic approaches to staffing on-orbit software maintenance, namely: (1) using the original developers, (2) using mission operations personnel, or (3) assembling a Center of Excellence for multi-spacecraft on-orbit FSW support. This paper explains a National Aeronautics and Space Administration, Goddard Space Flight Center (NASA/GSFC) experience related to the roles of on-orbit FSW maintenance personnel. It identifies the advantages and disadvantages of each of the three approaches to staffing the FSW roles, and demonstrates how a cost efficient on-orbit FSW Maintenance Center of Excellence can be established and maintained with significant return on the investment.
Verifying and Validating Proposed Models for FSW Process Optimization
NASA Technical Reports Server (NTRS)
Schneider, Judith
2008-01-01
This slide presentation reviews Friction Stir Welding (FSW) and the attempts to model the process in order to optimize and improve the process. The studies are ongoing to validate and refine the model of metal flow in the FSW process. There are slides showing the conventional FSW process, a couple of weld tool designs and how the design interacts with the metal flow path. The two basic components of the weld tool are shown, along with geometries of the shoulder design. Modeling of the FSW process is reviewed. Other topics include (1) Microstructure features, (2) Flow Streamlines, (3) Steady-state Nature, and (4) Grain Refinement Mechanisms
Speech intelligibility at high helium-oxygen pressures.
Rothman, H B; Gelfand, R; Hollien, H; Lambertsen, C J
1980-12-01
Word-list intelligibility scores of unprocessed speech (mean of 4 subjects) were recorded in helium-oxygen atmospheres at stable pressures equivalent to 1600, 1400, 1200, 1000, 860, 690, 560, 392, and 200 fsw daring Predictive Studies IV-1975 by wide-bandwidth condenser microphones (frequency responses not degraded by increased gas density). Intelligibility scores were substantially lower in helium-oxygen a 200 fsw than in air at l ATA, but there was little difference between 200 fsw and 1600 fsw. A previously documented prominent decrease in intelligibility of speech between 200 or 600 fsw because of helium and pressure was probably due to degradation of microphone frequency response by high gas density.
Microstructural Aspects in FSW and TIG Welding of Cast ZE41A Magnesium Alloy
NASA Astrophysics Data System (ADS)
Carlone, Pierpaolo; Astarita, Antonello; Rubino, Felice; Pasquino, Nicola
2016-04-01
In this paper, magnesium ZE41A alloy plates were butt joined through friction stir welding (FSW) and Tungsten Inert Gas welding processes. Process-induced microstructures were investigated by optical and SEM observations, EDX microanalysis and microhardness measurements. The effect of a post-welded T5 heat treatment on FSW joints was also assessed. Sound joints were produced by means of both techniques. Different elemental distributions and grain sizes were found, whereas microhardness profiles reflect microstructural changes. Post-welding heat treatment did not induce significant alterations in elemental distribution. The FSW-treated joint showed a more homogeneous hardness profile than the as-welded FSW joint.
29 CFR 1910.427 - Liveboating.
Code of Federal Regulations, 2011 CFR
2011-07-01
... deeper than 190 fsw, except that dives with bottom times of 30 minutes or less may be conducted to depths of 220 fsw; (3) Using mixed gas at depths greater than 220 fsw; (4) In rough seas which significantly...
Advanced Metalworking Solutions for Naval Systems that go in Harm’s Way
2009-01-01
friction stir welding (FSW) and advanced machining and casting techniques to produce a prototype Automated weld seam facing on DDG 1000 ships will...transportable friction stir welding (FSW) machine. FSW is a solid state joining technology that offers benefits over traditional welding for several...addition, by locating FSW operation at the construction yard, the aluminum panels that will be friction stir - welded are built to the size needed instead
NASA Technical Reports Server (NTRS)
Bhat, Biliyar N.; Carter, Robert W.; Ding, Robert J.; Lawless, Kirby G.; Nunes, Arthur C., Jr.; Russell, Carolyn K.; Shah, Sandeep R.; Munafo, Paul M. (Technical Monitor)
2001-01-01
This paper presents an over-view of friction stir welding (FSW) process development and applications at Marshall Space Flight Center (MSFC). FSW process development started as a laboratory curiosity but soon found support from many users. The FSW process advanced very quickly and has found many applications both within and outside the aerospace industry. It is currently being adapted for joining key elements of the Space Shuttle External Tank for improved producibility and reliability. FSW process modeling is done to better understand and improve the process. Special tools have been developed to weld variable thickness materials including very thin and very thick materials. FSW is now being applied to higher temperature materials such as copper and to advanced materials such as metal matrix composites. FSW technology is being successfully transferred from MSFC laboratory to shop floors of many commercial companies.
Ultrasonic imaging of material flaws exploiting multipath information
NASA Astrophysics Data System (ADS)
Shen, Xizhong; Zhang, Yimin D.; Demirli, Ramazan; Amin, Moeness G.
2011-05-01
In this paper, we consider ultrasonic imaging for the visualization of flaws in a material. Ultrasonic imaging is a powerful nondestructive testing (NDT) tool which assesses material conditions via the detection, localization, and classification of flaws inside a structure. Multipath exploitations provide extended virtual array apertures and, in turn, enhance imaging capability beyond the limitation of traditional multisensor approaches. We utilize reflections of ultrasonic signals which occur when encountering different media and interior discontinuities. The waveforms observed at the physical as well as virtual sensors yield additional measurements corresponding to different aspect angles. Exploitation of multipath information addresses unique issues observed in ultrasonic imaging. (1) Utilization of physical and virtual sensors significantly extends the array aperture for image enhancement. (2) Multipath signals extend the angle of view of the narrow beamwidth of the ultrasound transducers, allowing improved visibility and array design flexibility. (3) Ultrasonic signals experience difficulty in penetrating a flaw, thus the aspect angle of the observation is limited unless access to other sides is available. The significant extension of the aperture makes it possible to yield flaw observation from multiple aspect angles. We show that data fusion of physical and virtual sensor data significantly improves the detection and localization performance. The effectiveness of the proposed multipath exploitation approach is demonstrated through experimental studies.
Experimental Investigation on Friction Stir Welding of Cryorolled AA2219 Aluminum Alloy Joints
NASA Astrophysics Data System (ADS)
Babu, K. Kamal; Panneerselvam, K.; Sathiya, P.; Haq, A. Noorul; Sundarrajan, S.; Mastanaiah, P.; Murthy, C. V. Srinivasa
2017-07-01
In this paper, experimental investigation on cryorolled aluminum AA2219-T87 plate by using friction stir welding (FSW) process is carried out. AA2219-T87 plates with a size of 200×100×22.4 mm were rolled and reduced to 12.2mm thickness (more than 45% of reduction in total thickness of the base material) at cryogenic temperature (operating temperature range -90--30∘C). The cryorolled (CR) plates have reduced grain size, improved hardness and increased corrosion resistance property compared with the uncryorolled AA2219-T87 plates. FSW joints of cryorolled AA2219-T87 plates were prepared using cylindrical threaded FSW tool pin profile. Mechanical and metallurgical behaviors of friction stir welded joints were analyzed and the effects of the FSW process parameters are discussed in this paper. The variation of microhardness in the FSW joint regions were correlated with the microstructure of FSW joints. Cryorolled plate and FSW joints were tested for corrosion resistance using potentiodynamic polarization test. FSW joints shows better result during the corrosion resistance analysis compared to base AA2219-T87. The X-ray diffraction (XRD) test results showed that fine α-Al grains with eutectic phase (Al2Cu) were present in the weld nugget (WN). The large clusters of strengthening precipitates were reduced in size and merged with the weld nugget portion.
Morris, Chester N; Morris, Sheldon R; Ferguson, Alan G
2009-10-01
Female sex workers and their clients remain a high risk core group for HIV in Africa. We measured sexual behavior of a snowball sample of female sex workers (FSW) along the Trans Africa highway from Mombasa, Kenya to Kampala, Uganda and surveyed the availability of male condoms at 1,007 bars and lodgings in Kenya along the highway trucking stops where transactional sex occurs. There were 578 FSW one month sex diaries analyzed, 403 from Kenya and 175 from Uganda. Kenyan FSW had a median of 45 sexual acts per 28 days compared to 39 sex acts per 28 days by Ugandan FSW (P < 0.05). Condom use by FSW for all sexual liaisons was 79% in Kenya compared to 74% in Uganda. In multivariate analysis, adjusting for repeated measures, Kenyan FSW were more likely to use a condom by an adjusted odds ratio of 2.54 (95% confidence interval 1.89-3.41) compared to Ugandan FSW. Condom use with regular clients was 50.8% in Uganda compared with 68.7% in Kenya (P < 0.01). The number of sex workers reporting 100% condom use was 26.8% in Kenya and 18.9% in Uganda (P < 0.01). Bars and lodges in Kenya compared to Uganda were more likely to: have condom dispensers, 25% versus 1%, respectively (P < 0.01); distribute or sell condoms, 73.9% versus 47.6% (P < 0.01); and have more weekly condom distribution, 4.92 versus 1.27 condoms per seating capacity (P < 0.01). Our data indicate that in both countries condom use for FSW is suboptimal, particularly with regular partners, and greater condom use by Trans African highway FSW in Kenya compared to Uganda may be related to availability. Targeted interventions are warranted for FSW and truck drivers to prevent transmission in this important core group.
Ultrasonic power measurement system based on acousto-optic interaction.
He, Liping; Zhu, Fulong; Chen, Yanming; Duan, Ke; Lin, Xinxin; Pan, Yongjun; Tao, Jiaquan
2016-05-01
Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khafizov, M.; Pakarinen, J.; He, L.
We report on imaging subsurface grain microstructure using picosecond ultrasonics. This approach relies on elastic anisotropy of crystalline materials where ultrasonic velocity depends on propagation direction relative to the crystal axes. Picosecond duration ultrasonic pulses are generated and detected using ultrashort light pulses. In materials that are transparent or semitransparent to the probe wavelength, the probe monitors GHz Brillouin oscillations. The frequency of these oscillations is related to the ultrasonic velocity and the optical index of refraction. Ultrasonic waves propagating across a grain boundary experience a change in velocity due to a change in crystallographic orientation relative to the ultrasonicmore » propagation direction. This change in velocity is manifested as a change in the Brillouin oscillation frequency. Using the ultrasonic propagation velocity, the depth of the interface can be determined from the location in time of the transition in oscillation frequency. An image of the grain boundary is obtained by scanning the beam along the surface. We demonstrate this volumetric imaging capability using a polycrystalline UO 2 sample. As a result, cross section liftout analysis of the grain boundaries using electron microscopy were used to verify our imaging results.« less
Ultrasonic power measurement system based on acousto-optic interaction
NASA Astrophysics Data System (ADS)
He, Liping; Zhu, Fulong; Chen, Yanming; Duan, Ke; Lin, Xinxin; Pan, Yongjun; Tao, Jiaquan
2016-05-01
Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.
U.S. Drug Use and Migration experiences of Mexican Female Sex Workers who are injection Drug Users
Ojeda, Victoria D.; Burgos, José Luis; Rangel, María Gudelia; Lozada, Remedios; Vera, Alicia
2013-01-01
Objective To describe U.S.-based drug/sex behaviors and correlates of lifetime U.S. drug use by Mexican female sex workers who inject drugs (FSW-IDUs). Methods Between 2008–2010, 315 migrant FSW-IDUs residing in Tijuana and Ciudad Juarez, Mexico responded to questionnaires. Results Twenty-seven percent (n=85) of FSW-IDUs were U.S. migrants; of these, 46% (n=39) were deportees. One-half of U.S.-migrant FSW-IDUs consumed illicit drugs in the U.S., and two-thirds of these injected drugs in the U.S. Among U.S. injectors, over 75% ever received or shared used injection equipment. The majority (92%) of U.S.-migrant FSW-IDUs never obtained U.S. drug treatment services. HIV prevalence was 4% among U.S.-migrant and 5% among non-U.S. migrant FSW-IDUs; 100% of U.S.-migrant and 75% of non-U.S. migrant FSW-IDUs were unaware of their HIV status. Conclusions Binational coordination to improve access to substance use treatment and HIV testing services in Mexico and the U.S. among marginalized binational migrants may be critical to containing HIV transmission. PMID:23698687
U.S. drug use and migration experiences of Mexican female sex workers who are injection drug users.
Ojeda, Victoria D; Burgos, José Luis; Rangel, A Gudelia; Lozada, Remedios; Vera, Alicia
2012-11-01
To describe U.S.-based drug/sex behaviors and correlates of lifetime U.S. drug use by Mexican female sex workers who inject drugs (FSW-IDUs). Between 2008-2010, 315 migrant FSW-IDUs residing in Tijuana and Ciudad Juarez, Mexico responded to questionnaires. Twenty-seven percent (n=85) of FSW-IDUs were U.S. migrants; of these, 46% (n=39) were deportees. One-half of U.S.-migrant FSW-IDUs consumed illicit drugs in the U.S., and two-thirds of these injected drugs in the U.S. Among U.S. injectors, over 75% ever received or shared used injection equipment. The majority (92%) of U.S.-migrant FSW-IDUs never obtained U.S. drug treatment services. HIV prevalence was 4% among U.S.-migrant and 5% among non-U.S. migrant FSW-IDUs; 100% of U.S.-migrant and 75% of non-U.S. migrant FSW-IDUs were unaware of their HIV status. Binational coordination to improve access to substance use treatment and HIV testing services in Mexico and the U.S. among marginalized binational migrants may be critical to containing HIV transmission.
Wang, Lihong V.
2004-01-01
This article reviews two types of ultrasound-mediated biophotonic imaging–acousto-optical tomography (AOT, also called ultrasound-modulated optical tomography) and photo-acoustic tomography (PAT, also called opto-acoustic or thermo-acoustic tomography)–both of which are based on non-ionizing optical and ultrasonic waves. The goal of these technologies is to combine the contrast advantage of the optical properties and the resolution advantage of ultrasound. In these two technologies, the imaging contrast is based primarily on the optical properties of biological tissues, and the imaging resolution is based primarily on the ultrasonic waves that either are provided externally or produced internally, within the biological tissues. In fact, ultrasonic mediation overcomes both the resolution disadvantage of pure optical imaging in thick tissues and the contrast and speckle disadvantages of pure ultrasonic imaging. In our discussion of AOT, the relationship between modulation depth and acoustic amplitude is clarified. Potential clinical applications of ultrasound-mediated biophotonic imaging include early cancer detection, functional imaging, and molecular imaging. PMID:15096709
Internet (WWW) based system of ultrasonic image processing tools for remote image analysis.
Zeng, Hong; Fei, Ding-Yu; Fu, Cai-Ting; Kraft, Kenneth A
2003-07-01
Ultrasonic Doppler color imaging can provide anatomic information and simultaneously render flow information within blood vessels for diagnostic purpose. Many researchers are currently developing ultrasound image processing algorithms in order to provide physicians with accurate clinical parameters from the images. Because researchers use a variety of computer languages and work on different computer platforms to implement their algorithms, it is difficult for other researchers and physicians to access those programs. A system has been developed using World Wide Web (WWW) technologies and HTTP communication protocols to publish our ultrasonic Angle Independent Doppler Color Image (AIDCI) processing algorithm and several general measurement tools on the Internet, where authorized researchers and physicians can easily access the program using web browsers to carry out remote analysis of their local ultrasonic images or images provided from the database. In order to overcome potential incompatibility between programs and users' computer platforms, ActiveX technology was used in this project. The technique developed may also be used for other research fields.
Motion Estimation Using the Firefly Algorithm in Ultrasonic Image Sequence of Soft Tissue
Chao, Chih-Feng; Horng, Ming-Huwi; Chen, Yu-Chan
2015-01-01
Ultrasonic image sequence of the soft tissue is widely used in disease diagnosis; however, the speckle noises usually influenced the image quality. These images usually have a low signal-to-noise ratio presentation. The phenomenon gives rise to traditional motion estimation algorithms that are not suitable to measure the motion vectors. In this paper, a new motion estimation algorithm is developed for assessing the velocity field of soft tissue in a sequence of ultrasonic B-mode images. The proposed iterative firefly algorithm (IFA) searches for few candidate points to obtain the optimal motion vector, and then compares it to the traditional iterative full search algorithm (IFSA) via a series of experiments of in vivo ultrasonic image sequences. The experimental results show that the IFA can assess the vector with better efficiency and almost equal estimation quality compared to the traditional IFSA method. PMID:25873987
Motion estimation using the firefly algorithm in ultrasonic image sequence of soft tissue.
Chao, Chih-Feng; Horng, Ming-Huwi; Chen, Yu-Chan
2015-01-01
Ultrasonic image sequence of the soft tissue is widely used in disease diagnosis; however, the speckle noises usually influenced the image quality. These images usually have a low signal-to-noise ratio presentation. The phenomenon gives rise to traditional motion estimation algorithms that are not suitable to measure the motion vectors. In this paper, a new motion estimation algorithm is developed for assessing the velocity field of soft tissue in a sequence of ultrasonic B-mode images. The proposed iterative firefly algorithm (IFA) searches for few candidate points to obtain the optimal motion vector, and then compares it to the traditional iterative full search algorithm (IFSA) via a series of experiments of in vivo ultrasonic image sequences. The experimental results show that the IFA can assess the vector with better efficiency and almost equal estimation quality compared to the traditional IFSA method.
Le, Linh-Vi N; Nguyen, Tuan A; Tran, Hoang V; Gupta, Nisha; Duong, Thanh C; Tran, Ha T T; Nadol, Patrick; Sabin, Keith; Maher, Lisa; Kaldor, John M
2015-05-01
Women who sell sex and use drugs have dual risks for HIV infection. Despite increasing reports of drug use among female sex workers (FSW) in Vietnam, FSW HIV interventions remain focused mainly on sexual risk reduction. We assessed the impact of drug use and inconsistent condom use on HIV infection among FSW in Vietnam, which few studies have quantified. We surveyed 5298 women aged ≥18 years who had sold sex in the past month from ten geographically dispersed provinces. We performed multivariate logistic regression on data from provinces with high (≥10%) or low (<10%) HIV prevalence among FSW. Compared to FSW who never used illicit drugs, the odds of HIV infection among FSW who had ever injected drugs and those who reported non-injection drug use were 3.44 (CI 2.32-5.09) and 1.76 (CI 1.14-2.71), respectively, in high-prevalence provinces. FSW who always used condoms with clients had lower odds of HIV infection than those who did not (AOR=0.71; CI 0.52-0.98). In low-prevalence provinces lifetime injection drug use (AOR 22.05, CI 12.00-40.49), but not non-injecting drug use or inconsistent condom use, was significantly associated with HIV infection. Because injection drug use and inconsistent condom use were key risk factors for HIV infection in high-prevalence provinces, drug injection risk reduction should be as much a focus of HIV prevention as sexual risk reduction. Where HIV prevalence remains low in FSW, a more general emphasis on harm reduction for all drug users will benefit FSW. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Local defect resonance for sensitive non-destructive testing
NASA Astrophysics Data System (ADS)
Adebahr, W.; Solodov, I.; Rahammer, M.; Gulnizkij, N.; Kreutzbruck, M.
2016-02-01
Ultrasonic wave-defect interaction is a background of ultrasound activated techniques for imaging and non-destructive testing (NDT) of materials and industrial components. The interaction, primarily, results in acoustic response of a defect which provides attenuation and scattering of ultrasound used as an indicator of defects in conventional ultrasonic NDT. The derivative ultrasonic-induced effects include e.g. nonlinear, thermal, acousto-optic, etc. responses also applied for NDT and defect imaging. These secondary effects are normally relatively inefficient so that the corresponding NDT techniques require an elevated acoustic power and stand out from conventional ultrasonic NDT counterparts for their specific instrumentation particularly adapted to high-power ultrasonic. In this paper, a consistent way to enhance ultrasonic, optical and thermal defect responses and thus to reduce an ultrasonic power required is suggested by using selective ultrasonic activation of defects based on the concept of local defect resonance (LDR). A strong increase in vibration amplitude at LDR enables to reliably detect and visualize the defect as soon as the driving ultrasonic frequency is matched to the LDR frequency. This also provides a high frequency selectivity of the LDR-based imaging, i.e. an opportunity of detecting a certain defect among a multitude of other defects in material. Some examples are shown how to use LDR in non-destructive testing techniques, like vibrometry, ultrasonic thermography and shearography in order to enhance the sensitivity of defect visualization.
Three-dimensional imaging of biological cells with picosecond ultrasonics
NASA Astrophysics Data System (ADS)
Danworaphong, Sorasak; Tomoda, Motonobu; Matsumoto, Yuki; Matsuda, Osamu; Ohashi, Toshiro; Watanabe, Hiromu; Nagayama, Masafumi; Gohara, Kazutoshi; Otsuka, Paul H.; Wright, Oliver B.
2015-04-01
We use picosecond ultrasonics to image animal cells in vitro—a bovine aortic endothelial cell and a mouse adipose cell—fixed to Ti-coated sapphire. Tightly focused ultrashort laser pulses generate and detect GHz acoustic pulses, allowing three-dimensional imaging (x, y, and t) of the ultrasonic propagation in the cells with ˜1 μm lateral and ˜150 nm depth resolutions. Time-frequency representations of the continuous-wavelet-transform amplitude of the optical reflectivity variations inside and outside the cells show GHz Brillouin oscillations, allowing the average sound velocities of the cells and their ultrasonic attenuation to be obtained as well as the average bulk moduli.
Framework Based Guidance Navigation and Control Flight Software Development
NASA Technical Reports Server (NTRS)
McComas, David
2007-01-01
This viewgraph presentation describes NASA's guidance navigation and control flight software development background. The contents include: 1) NASA/Goddard Guidance Navigation and Control (GN&C) Flight Software (FSW) Development Background; 2) GN&C FSW Development Improvement Concepts; and 3) GN&C FSW Application Framework.
Inguane, Celso; Horth, Roberta Z; Miranda, Angélica E; Young, Peter W; Sathane, Isabel; Cummings, Beverley E; Augusto, Ângelo; Raymond, Henry F; Mcfarland, Willi
2015-12-01
Characteristics, HIV risk, and program coverage for underage female sex workers (FSW) are rarely systematically described worldwide. We compared characteristics of underage (15-17 years old) and adult (≥18 years old) FSW in three main urban areas of Mozambique (Maputo, Beira and Nampula) using data from three respondent-driven sampling surveys implemented in 2011-2012. Among survey participants, 9.8 % (39/400) in Maputo, 17.0 % (70/411) in Beira and 25.6 % (110/429) in Nampula were underage. Over half reported performing sex work to afford daily living, and 29.7-50.0 % had unprotected sex with their last client. The proportion of underage FSW having accessed care and prevention services was lower compared to adult FSW. While HIV prevalence among underage FSW was lower than in adults, it increased markedly with age. Our results point to the urgency of expanding prevention and care programs geared towards underage FSW.
Horth, Roberta Z.; Miranda, Angélica E.; Young, Peter W.; Sathane, Isabel; Cummings, Beverley E.; Augusto, Ângelo; Raymond, Henry F.; Mcfarland, Willi
2016-01-01
Characteristics, HIV risk, and program coverage for underage female sex workers (FSW) are rarely systematically described worldwide. We compared characteristics of underage (15–17 years old) and adult (≥18 years old) FSW in three main urban areas of Mozambique (Maputo, Beira and Nampula) using data from three respondent-driven sampling surveys implemented in 2011–2012. Among survey participants, 9.8 % (39/400) in Maputo, 17.0 % (70/411) in Beira and 25.6 % (110/429) in Nampula were underage. Over half reported performing sex work to afford daily living, and 29.7–50.0 % had unprotected sex with their last client. The proportion of underage FSW having accessed care and prevention services was lower compared to adult FSW. While HIV prevalence among underage FSW was lower than in adults, it increased markedly with age. Our results point to the urgency of expanding prevention and care programs geared towards underage FSW. PMID:25931241
Jiang, Xiaoyue; Tang, Hao-Yen; Lu, Yipeng; Ng, Eldwin J; Tsai, Julius M; Boser, Bernhard E; Horsley, David A
2017-09-01
In this paper, we present a single-chip 65 ×42 element ultrasonic pulse-echo fingerprint sensor with transmit (TX) beamforming based on piezoelectric micromachined ultrasonic transducers directly bonded to a CMOS readout application-specific integrated circuit (ASIC). The readout ASIC was realized in a standard 180-nm CMOS process with a 24-V high-voltage transistor option. Pulse-echo measurements are performed column-by-column in sequence using either one column or five columns to TX the ultrasonic pulse at 20 MHz. TX beamforming is used to focus the ultrasonic beam at the imaging plane where the finger is located, increasing the ultrasonic pressure and narrowing the 3-dB beamwidth to [Formula: see text], a factor of 6.4 narrower than nonbeamformed measurements. The surface of the sensor is coated with a poly-dimethylsiloxane (PDMS) layer to provide good acoustic impedance matching to skin. Scanning laser Doppler vibrometry of the PDMS surface was used to map the ultrasonic pressure field at the imaging surface, demonstrating the expected increase in pressure, and reduction in beamwidth. Imaging experiments were conducted using both PDMS phantoms and real fingerprints. The average image contrast is increased by a factor of 1.5 when beamforming is used.
Bradley, Janet; Moses, Stephen; Blanchard, James F; Rajaram, S; Ramesh, B M; Verma, Supriya; Alary, Michel
2010-02-01
A key indicator of success of HIV prevention programmes is the number of female sex worker (FSW) sex acts protected by condoms. This measure usually relies on FSW reports, which may be biased. We examined condom availability data in five Karnataka districts to estimate the proportion of FSW sex acts potentially protected by condoms. Financial, programme, population, condom and contraceptive data were obtained from governmental and non-governmental sources, surveys and HIV prevention programmes. Sexual behaviour data were obtained from general population and FSW surveys. We examined four scenarios in a sensitivity analysis, each one assuming different proportions of available condoms that might have been used by sex workers. Possible condom use rates for all FSW sex acts ranged from 3%-36% in 2004 to 56%-96% in 2008. The two most realistic scenarios that discounted the number of private sector condoms that might have been bought for sex acts other than with FSWs showed that 16-24% of FSW sex acts could have been protected by condoms in 2004 rising to 77-85% in 2008. These data suggest that condom availability in these Karnataka districts in 2004 was low in relation to the number of FSW sex acts, but rose substantially over the ensuing 4 years. Condom availability data can be useful for triangulation with other available data, such as self-reported condom use, to provide a range of possibilities regarding the number of FSW sex acts protected by condoms.
Performance Improvement of Friction Stir Welds by Better Surface Finish
NASA Technical Reports Server (NTRS)
Russell, Sam; Nettles, Mindy
2015-01-01
The as-welded friction stir weld has a cross section that may act as a stress concentrator. The geometry associated with the stress concentration may reduce the weld strength and it makes the weld challenging to inspect with ultrasound. In some cases, the geometry leads to false positive nondestructive evaluation (NDE) indications and, in many cases, it requires manual blending to facilitate the inspection. This study will measure the stress concentration effect and develop an improved phased array ultrasound testing (PAUT) technique for friction stir welding. Post-welding, the friction stir weld (FSW) tool would be fitted with an end mill that would machine the weld smooth, trimmed shaved. This would eliminate the need for manual weld preparation for ultrasonic inspections. Manual surface preparation is a hand operation that varies widely depending on the person preparing the welds. Shaving is a process that can be automated and tightly controlled.
[Development of a system for ultrasonic three-dimensional reconstruction of fetus].
Baba, K
1989-04-01
We have developed a system for ultrasonic three-dimensional (3-D) fetus reconstruction using computers. Either a real-time linear array probe or a convex array probe of an ultrasonic scanner was mounted on a position sensor arm of a manual compound scanner in order to detect the position of the probe. A microcomputer was used to convert the position information to what could be recorded on a video tape as an image. This image was superimposed on the ultrasonic tomographic image simultaneously with a superimposer and recorded on a video tape. Fetuses in utero were scanned in seven cases. More than forty ultrasonic section image on the video tape were fed into a minicomputer. The shape of the fetus was displayed three-dimensionally by means of computer graphics. The computer-generated display produced a 3-D image of the fetus and showed the usefulness and accuracy of this system. Since it took only a few seconds for data collection by ultrasonic inspection, fetal movement did not adversely affect the results. Data input took about ten minutes for 40 slices, and 3-D reconstruction and display took about two minutes. The system made it possible to observe and record the 3-D image of the fetus in utero non-invasively and therefore is expected to make it much easier to obtain a 3-D picture of the fetus in utero.
Multi-frequency Defect Selective Imaging via Nonlinear Ultrasound
NASA Astrophysics Data System (ADS)
Solodov, Igor; Busse, Gerd
The concept of defect-selective ultrasonic nonlinear imaging is based on visualization of strongly nonlinear inclusions in the form of localized cracked defects. For intense excitation, the ultrasonic response of defects is affected by mechanical constraint between their fragments that makes their vibrations extremely nonlinear. The cracked flaws, therefore, efficiently generate multiple new frequencies, which can be used as a nonlinear "tag" to detect and image them. In this paper, the methodologies of nonlinear scanning laser vibrometry (NSLV) and nonlinear air-coupled emission (NACE) are applied for nonlinear imaging of various defects in hi-tech and constructional materials. A broad database obtained demonstrates evident advantages of the nonlinear approach over its linear counterpart. The higher-order nonlinear frequencies provide increase in signal-to-noise ratio and enhance the contrast of imaging. Unlike conventional ultrasonic instruments, the nonlinear approach yields abundant multi-frequency information on defect location. The application of image recognition and processing algorithms is described and shown to improve reliability and quality of ultrasonic imaging.
Metal Flow in Friction Stir Welding
NASA Technical Reports Server (NTRS)
Nunes, Arthur C., Jr.
2006-01-01
The plastic deformation field in Friction Stir Welding (FSW) is compared to that in metal cutting. A shear surface around the FSW tool analogous to the metal cutting shear plane is identified and comprises the basis of the "rotating plug" flow field model and the "wiping" model of tool interaction with weld metal. Within the context of these models: The FSW shear rate is estimated to be comparable to metal cutting shear rates. The effect of tool geometry on the FSW shear surface is discussed and related to published torque measurements. Various FS W structural features are explained, including a difference in structure of bimetallic welds when alloys on the advancing and retreating sides of the weld seam are exchanged. The joining mechanism and critical parameters of the FSW process are made clear.
Partner Violence and Psychosocial Distress among Female Sex Workers in China
Hong, Yan; Zhang, Chen; Li, Xiaoming; Liu, Wei; Zhou, Yuejiao
2013-01-01
Background Despite recognized vulnerability of female sex workers (FSW), most data on this population are focused on their HIV and STI prevalence; studies on their experience of partner violence and psychosocial distress are limited, especially FSW in China. Methods and Findings A cross-sectional survey was administered among 1,022 FSW recruited from 9 different types of commercial sex venues in Southwest China. Partner violence scales were adapted from WHO's Women's Health and Domestic Violence scale and psychosocial distress was measured by five indicators, including alcohol intoxication, drug use, suicidal behavior, depression, and loneliness. Random effects modeling was used to control for cluster effects. Findings: About 58% of FSW ever experienced violence from their stable partners, and 45% suffered it from their clients. Partner violence was strongly associated with each of the five measures of psychosocial distress, even after controlling for potential confounders. Conclusion This study is one of the first to examine the association between partner violence and psychosocial distress among FSW in China. The high prevalence of violence experience and distress in this population suggests urgency for intervention. The public health programs targeting FSW should go beyond the focus on HIV/STI prevention and care for the fundamental health and human rights of millions of FSW in China. PMID:23626798
Kohler, Pamela K.; Campos, Pablo E.; Garcia, Patricia J.; Carcamo, Cesar P.; Buendia, Clara; Hughes, James P.; Mejia, Carolina; Garnett, Geoff P.; King, K.
2016-01-01
This study aims to evaluate condom use, STI screening, and knowledge of STI symptoms among female sex workers (FSW) in Peru associated with sex work venue and a community randomized trial of STI control. One component of the Peru PREVEN intervention conducted mobile-team outreach to FSW to reduce STIs and increase condom use and access to government clinics for STI screening and evaluation. Prevalence ratios were calculated using multivariate Poisson regression models with robust standard errors, clustering by city. As-treated analyses were conducted to assess outcomes associated with reported exposure to the intervention. Care-seeking was more frequent in intervention communities, but differences were not statistically significant. FSW reporting exposure to the intervention had significantly higher likelihood of condom use, STI screening at public health clinics, and symptom recognition compared to those not exposed. Compared with street or bar-based FSW, brothel-based FSW reported significantly higher rates of condom use with last client, recent screening exams for STIs and HIV testing. Brothel-based FSW also more often reported knowledge of STIs and recognition of STI symptoms in women and in men. Interventions to promote STI-detection and prevention among FSW in Peru should consider structural or regulatory factors related to sex work venue. PMID:25941053
21 CFR 870.2880 - Ultrasonic transducer.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer... ultrasonic energy that is used in conjunction with an echocardiograph to provide imaging of cardiovascular...
21 CFR 870.2880 - Ultrasonic transducer.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer... ultrasonic energy that is used in conjunction with an echocardiograph to provide imaging of cardiovascular...
NASA Astrophysics Data System (ADS)
Wagle, Sanat; Habib, Anowarul; Melandsø, Frank
2017-07-01
High-frequency transducers made from a layer-by-layer deposition method are investigated as transducers for ultrasonic imaging. Prototypes of adhesive-free transducers with four active elements were made on a high-performance poly(ether imide) substrate with precision milled spherical cavities used to produce focused ultrasonic beams. The transducer prototypes were characterized using a pulse-echo experimental setup in a water tank using a glass plate as a reflector. Then, transducer was used in a three-dimensional ultrasonic scanning tank, to produce high-resolution ultrasonic images of flexible electronic circuits with the aim to detect defects in the outermost cover layer.
NASA Astrophysics Data System (ADS)
Akiyama, Iwaki; Yoshizumi, Natsuki; Saito, Shigemi; Wada, Yuji; Koyama, Daisuke; Nakamura, Kentaro
2012-07-01
The authors have developed a multiple frequency imaging system using a multiple resonance transducer (MRT) consisting of 1-3 composite materials with a low mechanical quality factor Q bonded together. The MRT has a structure consisting of thin and thick piezoelectric plates, two matching layers, and a backing layer. This makes it possible to obtain B-mode images of satisfactory resolution using ultrasonic pulses owing to their short duration. In this paper, the vibration property of the MRT derived through equivalent-circuit analysis is first shown. By utilizing the result, an MRT capable of transmitting ultrasonic pulses for generation of the images of biological tissues with satisfactory resolution is designed and prototyped. Setting the prototype transducer in the mechanical sector probe of commercial ultrasonic diagnosis equipment, the speckle reduction effect is demonstrated using images of various phantoms to mimic biological tissues and a human thyroid.
NASA Astrophysics Data System (ADS)
Isono, Hiroshi; Hirata, Shinnosuke; Hachiya, Hiroyuki
2015-07-01
In medical ultrasonic images of liver disease, a texture with a speckle pattern indicates a microscopic structure such as nodules surrounded by fibrous tissues in hepatitis or cirrhosis. We have been applying texture analysis based on a co-occurrence matrix to ultrasonic images of fibrotic liver for quantitative tissue characterization. A co-occurrence matrix consists of the probability distribution of brightness of pixel pairs specified with spatial parameters and gives new information on liver disease. Ultrasonic images of different types of fibrotic liver were simulated and the texture-feature contrast was calculated to quantify the co-occurrence matrices generated from the images. The results show that the contrast converges with a value that can be theoretically estimated using a multi-Rayleigh model of echo signal amplitude distribution. We also found that the contrast value increases as liver fibrosis progresses and fluctuates depending on the size of fibrotic structure.
Fei, Chunlong; Chiu, Chi Tat; Chen, Xiaoyang; Chen, Zeyu; Ma, Jianguo; Zhu, Benpeng; Shung, K. Kirk; Zhou, Qifa
2016-01-01
High resolution ultrasonic imaging requires high frequency wide band ultrasonic transducers, which produce short pulses and highly focused beam. However, currently the frequency of ultrasonic transducers is limited to below 100 MHz, mainly because of the challenge in precise control of fabrication parameters. This paper reports the design, fabrication, and characterization of sensitive broadband lithium niobate (LiNbO3) single element ultrasonic transducers in the range of 100–300 MHz, as well as their applications in high resolution imaging. All transducers were built for an f-number close to 1.0, which was achieved by press-focusing the piezoelectric layer into a spherical curvature. Characterization results demonstrated their high sensitivity and a −6 dB bandwidth greater than 40%. Resolutions better than 6.4 μm in the lateral direction and 6.2 μm in the axial direction were achieved by scanning a 4 μm tungsten wire target. Ultrasonic biomicroscopy images of zebrafish eyes were obtained with these transducers which demonstrate the feasibility of high resolution imaging with a performance comparable to optical resolution. PMID:27329379
High Speed Imaging of Cavitation around Dental Ultrasonic Scaler Tips.
Vyas, Nina; Pecheva, Emilia; Dehghani, Hamid; Sammons, Rachel L; Wang, Qianxi X; Leppinen, David M; Walmsley, A Damien
2016-01-01
Cavitation occurs around dental ultrasonic scalers, which are used clinically for removing dental biofilm and calculus. However it is not known if this contributes to the cleaning process. Characterisation of the cavitation around ultrasonic scalers will assist in assessing its contribution and in developing new clinical devices for removing biofilm with cavitation. The aim is to use high speed camera imaging to quantify cavitation patterns around an ultrasonic scaler. A Satelec ultrasonic scaler operating at 29 kHz with three different shaped tips has been studied at medium and high operating power using high speed imaging at 15,000, 90,000 and 250,000 frames per second. The tip displacement has been recorded using scanning laser vibrometry. Cavitation occurs at the free end of the tip and increases with power while the area and width of the cavitation cloud varies for different shaped tips. The cavitation starts at the antinodes, with little or no cavitation at the node. High speed image sequences combined with scanning laser vibrometry show individual microbubbles imploding and bubble clouds lifting and moving away from the ultrasonic scaler tip, with larger tip displacement causing more cavitation.
High Speed Imaging of Cavitation around Dental Ultrasonic Scaler Tips
Vyas, Nina; Pecheva, Emilia; Dehghani, Hamid; Sammons, Rachel L.; Wang, Qianxi X.; Leppinen, David M.; Walmsley, A. Damien
2016-01-01
Cavitation occurs around dental ultrasonic scalers, which are used clinically for removing dental biofilm and calculus. However it is not known if this contributes to the cleaning process. Characterisation of the cavitation around ultrasonic scalers will assist in assessing its contribution and in developing new clinical devices for removing biofilm with cavitation. The aim is to use high speed camera imaging to quantify cavitation patterns around an ultrasonic scaler. A Satelec ultrasonic scaler operating at 29 kHz with three different shaped tips has been studied at medium and high operating power using high speed imaging at 15,000, 90,000 and 250,000 frames per second. The tip displacement has been recorded using scanning laser vibrometry. Cavitation occurs at the free end of the tip and increases with power while the area and width of the cavitation cloud varies for different shaped tips. The cavitation starts at the antinodes, with little or no cavitation at the node. High speed image sequences combined with scanning laser vibrometry show individual microbubbles imploding and bubble clouds lifting and moving away from the ultrasonic scaler tip, with larger tip displacement causing more cavitation. PMID:26934340
Bautista, Christian T; Mejía, Alfredo; Leal, Luis; Ayala, Claudia; Sanchez, Jose L; Montano, Silvia M
2008-03-01
The primary objective was to estimate the lifetime prevalence of abortion and the secondary objective was to describe the use of contraceptive methods among female sex workers (FSW) in Bogota, Colombia. A cross-sectional survey was conducted among FSW. Information on sociodemographic characteristics, contraceptive methods, number of abortions, reasons for abortions and sexual practices was collected. A total of 514 FSW were enrolled. Of these, 264 (53%) had a lifetime abortion. Age, years in sex work and a previous sexually transmitted infection were associated with abortion. A total of 89 FSW(17%) reported no contraception method. Oral contraceptives, use of condoms, female sterilization and intrauterine device insertion were the most common methods of contraception. Women who were poorer, who initiated sex work at a younger age and who reported use of illegal drugs were associated with inconsistent contraception. A high lifetime prevalence of abortion and inconsistent contraception was found among FSW in Bogota. There is a need for effective and practical contraceptive methods of family health planning among FSW in Colombia.
Generating porosity spectrum of carbonate reservoirs using ultrasonic imaging log
NASA Astrophysics Data System (ADS)
Zhang, Jie; Nie, Xin; Xiao, Suyun; Zhang, Chong; Zhang, Chaomo; Zhang, Zhansong
2018-03-01
Imaging logging tools can provide us the borehole wall image. The micro-resistivity imaging logging has been used to obtain borehole porosity spectrum. However, the resistivity imaging logging cannot cover the whole borehole wall. In this paper, we propose a method to calculate the porosity spectrum using ultrasonic imaging logging data. Based on the amplitude attenuation equation, we analyze the factors affecting the propagation of wave in drilling fluid and formation and based on the bulk-volume rock model, Wyllie equation and Raymer equation, we establish various conversion models between the reflection coefficient β and porosity ϕ. Then we use the ultrasonic imaging logging and conventional wireline logging data to calculate the near-borehole formation porosity distribution spectrum. The porosity spectrum result obtained from ultrasonic imaging data is compared with the one from the micro-resistivity imaging data, and they turn out to be similar, but with discrepancy, which is caused by the borehole coverage and data input difference. We separate the porosity types by performing threshold value segmentation and generate porosity-depth distribution curves by counting with equal depth spacing on the porosity image. The practice result is good and reveals the efficiency of our method.
A Brief Introduction to the Theory of Friction Stir Welding
NASA Technical Reports Server (NTRS)
Nunes, Arthur C., Jr.
2008-01-01
Friction stir welding (FSW) is a solid state welding process invented in 1991 at The Welding Institute in the United Kingdom. A weld is made in the FSW process by translating a rotating pin along a weld seam so as to stir the sides of the seam together. FSW avoids deleterious effects inherent in melting and is already an important welding process for the aerospace industry, where welds of optimal quality are demanded. The structure of welds determines weld properties. The structure of friction stir welds is determined by the flow field in the weld metal in the vicinity of the weld tool. A simple kinematic model of the FSW flow field developed at Marshall Space Flight Center, which enables the basic features of FSW microstructure to be understood and related to weld process parameters and tool design, is explained.
Microstructure and Mechanical Property Change During FSW and GTAW of Al6061 Alloy
NASA Astrophysics Data System (ADS)
Fahimpour, V.; Sadrnezhaad, S. K.; Karimzadeh, F.
2013-05-01
The variation of morphology and mechanical properties of Al6061 automotive aluminum alloy due to friction stir welding (FSW) and gas tungsten arc welding (GTAW) was investigated by optical metallography, scanning electron microscopy, microhardness measurement, X-ray diffraction, tensile testing, and fractography. The center-line dendrite emergence and microhardness reduction in the heat-affected zone were observed in the GTAW process. Although similar microhardness reduction with respect to the base metal was observed in the FSW samples, higher HVs were obtained for the FSW rather than the GTAW process at almost all heat-affected locations. Ultimate tensile strengths of the FSW and the GTAW samples in the transverse direction were ~0.57 and ~0.35 of the base metal, respectively. Post-weld aging improved the strength, but reduced the ductility of the welding.
On a Formal Tool for Reasoning About Flight Software Cost Analysis
NASA Technical Reports Server (NTRS)
Spagnuolo, John N., Jr.; Stukes, Sherry A.
2013-01-01
A report focuses on the development of flight software (FSW) cost estimates for 16 Discovery-class missions at JPL. The techniques and procedures developed enabled streamlining of the FSW analysis process, and provided instantaneous confirmation that the data and processes used for these estimates were consistent across all missions. The research provides direction as to how to build a prototype rule-based system for FSW cost estimation that would provide (1) FSW cost estimates, (2) explanation of how the estimates were arrived at, (3) mapping of costs, (4) mathematical trend charts with explanations of why the trends are what they are, (5) tables with ancillary FSW data of interest to analysts, (6) a facility for expert modification/enhancement of the rules, and (7) a basis for conceptually convenient expansion into more complex, useful, and general rule-based systems.
Human papillomavirus infection in female sex workers in Lima, Peru.
Montano, Silvia M; Hsieh, Evelyn J; Calderón, Martha; Ton, Thanh G N; Quijano, Eberth; Solari, Vicky; Zunt, Joseph R
2011-02-01
To determine the prevalence and risk factors for human papillomavirus (HPV) infection in female sex workers (FSW) in Lima, Peru. Cross-sectional study of 87 FSW. Information regarding demographics, sex work practices, and genital and blood specimens was collected. Forty-four (50.6%) of 87 FSW had HPV detected in cervical swabs. The prevalence of coinfection by two or more HPV types was 39.1%. Thirty-one (35.6%) were infected by at least one high-risk HPV type, representing 70.5% of women with HPV infection. HPV infection was associated with younger age but not with any demographic or sexual characteristics. Our study confirms the high prevalence of HPV infection in FSW reported by other groups and suggests that brothel-based FSW may be at lower risk for acquiring high-risk HPV infection.
Ma, Teng; Zhang, Xiangyang; Chiu, Chi Tat; Chen, Ruimin; Kirk Shung, K.; Zhou, Qifa; Jiao, Shuliang
2014-01-01
Abstract. Photoacoustic ophthalmoscopy (PAOM) is a high-resolution in vivo imaging modality that is capable of providing specific optical absorption information for the retina. A high-frequency ultrasonic transducer is one of the key components in PAOM, which is in contact with the eyelid through coupling gel during imaging. The ultrasonic transducer plays a crucial role in determining the image quality affected by parameters such as spatial resolution, signal-to-noise ratio, and field of view. In this paper, we present the results of a systematic study on a high-frequency ultrasonic transducer design for PAOM. The design includes piezoelectric material selection, frequency selection, and the fabrication process. Transducers of various designs were successfully applied for capturing images of biological samples in vivo. The performances of these designs are compared and evaluated. PMID:24441942
Ma, Teng; Zhang, Xiangyang; Chiu, Chi Tat; Chen, Ruimin; Kirk Shung, K; Zhou, Qifa; Jiao, Shuliang
2014-01-01
Photoacoustic ophthalmoscopy (PAOM) is a high-resolution in vivo imaging modality that is capable of providing specific optical absorption information for the retina. A high-frequency ultrasonic transducer is one of the key components in PAOM, which is in contact with the eyelid through coupling gel during imaging. The ultrasonic transducer plays a crucial role in determining the image quality affected by parameters such as spatial resolution, signal-to-noise ratio, and field of view. In this paper, we present the results of a systematic study on a high-frequency ultrasonic transducer design for PAOM. The design includes piezoelectric material selection, frequency selection, and the fabrication process. Transducers of various designs were successfully applied for capturing images of biological samples in vivo. The performances of these designs are compared and evaluated.
NASA Technical Reports Server (NTRS)
Miller, James G.
1994-01-01
In this Progress Report, we describe our continuing research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the inspection and characterization of complex composite structures. We explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize complex materials. As an initial step toward the application of linear array imaging technology to the interrogation of a wide range of complex composite structures, we present images obtained using an unmodified medical ultrasonic imaging system of two epoxy-bonded aluminum plate specimens, each with intentionally disbonded regions. These images are compared with corresponding conventional ultrasonic contact transducer measurements in order to assess whether these images can detect disbonded regions and provide information regarding the nature of the disbonded region. We present a description of a standoff/delay fixture which has been designed, constructed, and implemented on a Hewlett-Packard SONOS 1500 medical imaging system. This standoff/delay fixture, when attached to a 7.5 MHz linear array probe, greatly enhances our ability to interrogate flat plate specimens. The final section of this Progress Report describes a woven composite plate specimen that has been specially machined to include intentional flaws. This woven composite specimen will allow us to assess the feasibility of applying linear array imaging technology to the inspection and characterization of complex textile composite materials. We anticipate the results of this on-going investigation may provide a step toward the development of a rapid, real-time, and portable method of ultrasonic inspection and characterization based on linear array technology.
Friction Stir Welding at MSFC: Kinematics
NASA Technical Reports Server (NTRS)
Nunes, A. C., Jr.
2001-01-01
In 1991 The Welding Institute of the United Kingdom patented the Friction Stir Welding (FSW) process. In FSW a rotating pin-tool is inserted into a weld seam and literally stirs the faying surfaces together as it moves up the seam. By April 2000 the American Welding Society International Welding and Fabricating Exposition featured several exhibits of commercial FSW processes and the 81st Annual Convention devoted a technical session to the process. The FSW process is of interest to Marshall Space Flight Center (MSFC) as a means of avoiding hot-cracking problems presented by the 2195 aluminum-lithium alloy, which is the primary constituent of the Lightweight Space Shuttle External Tank. The process has been under development at MSFC for External Tank applications since the early 1990's. Early development of the FSW process proceeded by cut-and-try empirical methods. A substantial and complex body of data resulted. A theoretical model was wanted to deal with the complexity and reduce the data to concepts serviceable for process diagnostics, optimization, parameter selection, etc. A first step in understanding the FSW process is to determine the kinematics, i.e., the flow field in the metal in the vicinity of the pin-tool. Given the kinematics, the dynamics, i.e., the forces, can be targeted. Given a completed model of the FSW process, attempts at rational design of tools and selection of process parameters can be made.
Computational Analysis of Material Flow During Friction Stir Welding of AA5059 Aluminum Alloys
NASA Astrophysics Data System (ADS)
Grujicic, M.; Arakere, G.; Pandurangan, B.; Ochterbeck, J. M.; Yen, C.-F.; Cheeseman, B. A.; Reynolds, A. P.; Sutton, M. A.
2012-09-01
Workpiece material flow and stirring/mixing during the friction stir welding (FSW) process are investigated computationally. Within the numerical model of the FSW process, the FSW tool is treated as a Lagrangian component while the workpiece material is treated as an Eulerian component. The employed coupled Eulerian/Lagrangian computational analysis of the welding process was of a two-way thermo-mechanical character (i.e., frictional-sliding/plastic-work dissipation is taken to act as a heat source in the thermal-energy balance equation) while temperature is allowed to affect mechanical aspects of the model through temperature-dependent material properties. The workpiece material (AA5059, solid-solution strengthened and strain-hardened aluminum alloy) is represented using a modified version of the classical Johnson-Cook model (within which the strain-hardening term is augmented to take into account for the effect of dynamic recrystallization) while the FSW tool material (AISI H13 tool steel) is modeled as an isotropic linear-elastic material. Within the analysis, the effects of some of the FSW key process parameters are investigated (e.g., weld pitch, tool tilt-angle, and the tool pin-size). The results pertaining to the material flow during FSW are compared with their experimental counterparts. It is found that, for the most part, experimentally observed material-flow characteristics are reproduced within the current FSW-process model.
High frequency ultrasound: a new frontier for ultrasound.
Shung, K; Cannata, Jonathan; Qifa Zhou, Member; Lee, Jungwoo
2009-01-01
High frequency ultrasonic imaging is considered by many to be the next frontier in ultrasonic imaging because higher frequencies yield much improved spatial resolution by sacrificing the depth of penetration. It has many clinical applications including visualizing blood vessel wall, anterior segments of the eye and skin. Another application is small animal imaging. Ultrasound is especially attractive in imaging the heart of a small animal like mouse which has a size in the mm range and a heart beat rate faster than 600 BPM. A majority of current commercial high frequency scanners often termed "ultrasonic backscatter microscope or UBM" acquire images by scanning single element transducers at frequencies between 50 to 80 MHz with a frame rate lower than 40 frames/s, making them less suitable for this application. High frequency linear arrays and linear array based ultrasonic imaging systems at frequencies higher than 30 MHz are being developed. The engineering of such arrays and development of high frequency imaging systems has been proven to be highly challenging. High frequency ultrasound may find other significant biomedical applications. The development of acoustic tweezers for manipulating microparticles is such an example.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Kiser, James D.; Swickard, Suzanne M.; Szatmary, Steven A.; Kerwin, David P.
1993-01-01
An ultrasonic scan procedure using the pulse-echo contact configuration was employed to obtain maps of pore fraction variations in sintered silicon nitride samples in terms of ultrasonic material properties. Ultrasonic velocity, attenuation coefficient, and reflection coefficient images were obtained simultaneously over a broad band of frequencies (e.g., 30 to 110 MHz) by using spectroscopic analysis. Liquid and membrane (dry) coupling techniques and longitudinal and shear-wave energies were used. The major results include the following: Ultrasonic velocity (longitudinal and shear wave) images revealed and correlated with the extent of average through-thickness pore fraction variations in the silicon nitride disks. Attenuation coefficient images revealed pore fraction nonuniformity due to the scattering that occurred at boundaries between regions of high and low pore fraction. Velocity and attenuation coefficient images were each nearly identical for machined and polished disks, making the method readily applicable to machined materials. Velocity images were similar for wet and membrane coupling. Maps of apparent Poisson's ratio constructed from longitudinal and shear-wave velocities quantified Poisson's ratio variations across a silicon nitride disk. Thermal wave images of a disk indicated transient thermal behavior variations that correlated with observed variations in pore fraction and velocity and attenuation coefficients.
Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance.
DOT National Transportation Integrated Search
2017-04-01
This report describes work on laboratory and field performance reviews of an ultrasonic shear wave imaging device called MIRA : for application to plain and reinforced concrete infrastructure components. Potential applications investigated included b...
Tool for Two Types of Friction Stir Welding
NASA Technical Reports Server (NTRS)
Carter, Robert
2006-01-01
A tool that would be useable in both conventional and self-reacting friction stir welding (FSW) has been proposed. The tool would embody both a prior tooling concept for self-reacting FSW and an auto-adjustable pin-tool (APT) capability developed previously as an augmentation for conventional FSW. Some definitions of terms are prerequisite to a meaningful description of the proposed tool. In conventional FSW, depicted in Figure 1, one uses a tool that includes (1) a rotating shoulder on top (or front) of the workpiece and (2) a rotating pin that protrudes from the shoulder into the depth of the workpiece. The main axial force exerted by the tool on the workpiece is reacted through a ridged backing anvil under (behind) the workpiece. When conventional FSW is augmented with an APT capability, the depth of penetration of the pin into the workpiece is varied in real time by a position- or force-control system that extends or retracts the pin as needed to obtain the desired effect. In self-reacting (also known as self-reacted) friction stir welding (SR-FSW), there are two rotating shoulders: one on top (or front) and one on the bottom (or back) of the workpiece. In this case, a threaded shaft protrudes from the tip of the pin to beyond the back surface of the workpiece. The back shoulder is held axially in place against tension by a nut on the threaded shaft. The main axial force exerted on the workpiece by the tool and front shoulder is reacted through the back shoulder and the threaded shaft, back into the FSW machine head, so that a backing anvil is no longer needed. A key transmits torque between the bottom shoulder and the threaded shaft, so that the bottom shoulder rotates with the shaft. A tool for SRFSW embodying this concept was reported in "Mechanism for Self-Reacted Friction Stir Welding" (MFS-31914), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 53. In its outward appearance, the proposed tool (see Figure 2) would fit the above description of an SR-FSW tool. In this case, the FSW machine would have an APT capability and the pin would be modified to accept a bottom shoulder. The APT capability could be used to vary the distance between the front and back shoulders in real time to accommodate process and workpiece-thickness variations. The tool could readily be converted to a conventional FSW tool, with or without APT capability, by simply replacing the modified pin with a conventional FSW pin.
Lancaster, Kathryn E; MacLean, Sarah A; Lungu, Thandie; Mmodzi, Pearson; Hosseinipour, Mina C; Hershow, Rebecca B; Powers, Kimberly A; Pence, Brian W; Hoffman, Irving F; Miller, William C; Go, Vivian F
2018-04-16
Alcohol use is pervasive among female sex workers (FSW) placing them at increased risk of violence and sexual risk behaviors. FSW often live and work where alcohol is highly normative. To understand the socioecological influences on hazardous alcohol use among FSW in Malawi. In 2014, 200 FSW identified through venue-based sampling in Lilongwe, Malawi, completed a quantitative behavioral survey, with a sub-sample participating in qualitative interviews. Multivariable log-binomial regression was used to identify associations between hazardous alcohol use (AUDIT score ≥ 7) and time in sex work, clients per week, unprotected sex, alcohol use with clients, and living environment. Qualitative interviews enhanced findings from quantitative data and identify emergent themes around socioecological influences on alcohol use. Over 50% reported hazardous alcohol use and lived in an alcohol-serving venue. Hazardous alcohol use was associated with sex work duration of ≥2 years (aPR: 1.30; 95%CI: 1.02,1.65) and alcohol use at last sex with a client (aPR: 1.29; 95%CI: 1.06,1.57). FSW perceived alcohol as a facilitator for sex work by reducing inhibitions and attracting clients, but acknowledged alcohol leads to violence and/or unprotected sex. Despite these risks and a motivation to reduce use, FSW feared that refusing to drink would be tantamount to turning away clients. Although FSW recognized alcohol-related risks, the norms and power dynamics of sex work perpetuated hazardous alcohol use. Multilevel interventions are needed to collectively change norms around drinking and sex work that will enable FSW to reduce alcohol consumption when engaging in their work.
Micheni, Murugi; Rogers, Sam; Wahome, Elizabeth; Darwinkel, Marianne; van der Elst, Elise; Gichuru, Evans; Graham, Susan M; Sanders, Eduard J; Smith, Adrian D
2015-12-01
Violence toward MSM and female sex workers (FSW) is associated with HIV risk, and its prevention is prioritized in international HIV/AIDS policy. Sociodemographic and behavioural data derived from HIV risk and follow-up cohorts including MSM and FSW in coastal Kenya between 2005 and 2014 was used to estimate the risk of rape, physical assault and verbal abuse, and to assess associations between first occurrence of assault with individual and recent behavioural factors. Incidence of first reported rape was similar for MSM [3.9, confidence interval (CI) 3.1-5.0 per 100 person-years (pyrs)] and FSW (4.8 CI 3.5-6.4 per 100 pyrs), P = 0.22. Incidence of first reported physical and verbal assault was higher for FSW than MSM (21.1 versus 12.9 per 100 pyrs, P = 0.14 and 51.3 versus 30.9 per 100 pyrs, P = 0.03 respectively). Recent alcohol use was associated with reporting of all forms of assault by MSM [adjusted odds ratio (AOR) 1.8, CI 0.9-3.5] and FSW (AOR 4.4, CI 1.41-14.0), as was recent sale of sex for MSM (AOR 2.0, CI 1.1-3.8). Exclusive sex with men, active sex work, and group sex were also specifically associated with reporting rape for MSM. Perpetrators of sexual and verbal assault were usually unknown, whilst perpetrators of physical violence toward FSW were usually regular sexual partners. MSM and FSW experienced a similarly high incidence of sexual assault in coastal Kenya, in addition to physical and verbal assault. Current national policies focus heavily on gender-based violence against women and young girls, but need to be inclusive of MSM and FSW.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Carney, Dorothy V.; Baaklini, George Y.; Bodis, James R.; Rauser, Richard W.
1998-01-01
Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Liping; Zhu, Fulong, E-mail: zhufulong@hust.edu.cn; Duan, Ke
Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of opticalmore » devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.« less
Time reversal for ultrasonic transcranial surgery and echographic imaging
NASA Astrophysics Data System (ADS)
Tanter, Mickael; Aubry, Jean-Francois; Vignon, Francois; Fink, Mathias
2005-09-01
High-intensity focused ultrasound (HIFU) is able to induce non-invasively controlled and selective destruction of tissues by focusing ultrasonic beams within organs, analogous to a magnifying glass that concentrates enough sunlight to burn a hole in paper. The brain is an attractive organ in which to perform ultrasonic tissue ablation, but such an application has been hampered by the strong defocusing effect of the skull bone. Our group has been involved in this topic for several years, providing proofs of concept and proposing technological solutions to this problem. Thanks to a high-power time-reversal mirror, presented here are in vivo thermal lesions induced through the skull of 12 sheep. Thermal lesions were confirmed by T2-weighted magnetic resonance post-treatment images and histological examination. These results provide striking evidence that noninvasive ultrasound brain surgery is feasible. A recent approach for high-resolution brain ultrasonic imaging will also be discussed with a skull aberration correction technique based on twin arrays technology. The correction of transcranial ultrasonic images is implemented on a new generation of time-reversal mirrors relying on a fully programmable transmit and receive beamformer.
Zhang, Siyuan; Han, Yuqiang; Zhu, Xingguang; Shang, Shaoqiang; Huang, Guojing; Zhang, Lei; Niu, Gang; Wang, Supin; He, Xijing; Wan, Mingxi
2017-02-01
The feasibility of using ultrasonic Nakagami imaging to evaluate thermal lesions induced by microwave ablation (MWA) in ex vivo porcine liver was explored. Dynamic changes in echo amplitudes and Nakagami parameters in the region of the MWA-induced thermal lesion, as well as the contrast-to-noise ratio (CNR) between the MWA-induced thermal lesion and the surrounding normal tissue, were calculated simultaneously during the MWA procedure. After MWA exposure, a bright hyper-echoic region appeared in ultrasonic B-mode and Nakagami parameter images as an indicator of the thermal lesion. Mean values of the Nakagami parameter in the thermal lesion region increased to 0.58, 0.71 and 0.91 after 1, 3 and 5 min of MVA. There were no significant differences in envelope amplitudes in the thermal lesion region among ultrasonic B-mode images obtained after different durations of MWA. Unlike ultrasonic B-mode images, Nakagami images were less affected by the shadow effect in monitoring of MWA exposure, and a fairly complete hyper-echoic region was observed in the Nakagami image. The mean value of the Nakagami parameter increased from approximately 0.47 to 0.82 during MWA exposure. At the end of the postablation stage, the mean value of the Nakagami parameter decreased to 0.55 and was higher than that before MWA exposure. CNR values calculated for Nakagami parameter images increased from 0.13 to approximately 0.61 during MWA and then decreased to 0.26 at the end of the post-ablation stage. The corresponding CNR values calculated for ultrasonic B-mode images were 0.24, 0.42 and 0.17. This preliminary study on ex vivo porcine liver suggested that Nakagami imaging have potential use in evaluating the formation of MWA-induced thermal lesions. Further in vivo studies are needed to evaluate the potential application. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Preliminary study of ultrasonic structural quality control of Swiss-type cheese.
Eskelinen, J J; Alavuotunki, A P; Haeggström, E; Alatossava, T
2007-09-01
There is demand for a new nondestructive cheese-structure analysis method for Swiss-type cheese. Such a method would provide the cheese-making industry the means to enhance process control and quality assurance. This paper presents a feasibility study on ultrasonic monitoring of the structural quality of Swiss cheese by using a single-transducer 2-MHz longitudinal mode pulse-echo setup. A volumetric ultrasonic image of a cheese sample featuring gas holes (cheese-eyes) and defects (cracks) in the scan area is presented. The image is compared with an optical reference image constructed from dissection images of the same sample. The results show that the ultrasonic method is capable of monitoring the gas-solid structure of the cheese during the ripening process. Moreover, the method can be used to detect and to characterize cheese-eyes and cracks in ripened cheese. Industrial application demands were taken into account when conducting the measurements.
Psychological Stressors in the Context of Commercial Sex Among Female Sex Workers in China
Zhang, Chen; Hong, Yan; Li, Xiaoming; Qiao, Shan; Zhou, Yuejiao; Su, Shaobing
2014-01-01
Because of the illegality and stigma associated with female sex workers (FSW) in China, data were limited regarding their psychological stressors examined through the lens of occupational health. Analyzing qualitative data from 16 gatekeepers and 38 FSW, we explored these stressors in the context of commercial sex in China. We found that FSW faced a continuum of stressors that resulted from poverty, limited employment, lack of social protection, violence perpetrated by clients, and limited social support from peers and stable partners. We call for empowerment and a structural approach to address the needs of FSW to improve their psychological well-being. PMID:24180467
A Border Context of Violence: Mexican Female Sex Workers on the U.S.–Mexico Border
Cepeda, Alice; Nowotny, Kathryn M.
2018-01-01
Female sex workers (FSW) represent a population confronted with an array of intersecting social problems. We explore the case of FSW in Nuevo Laredo and Ciudad Juarez to understand the everyday violence associated with sex work within the unique context of Mexico. Life history interviews were conducted with 109 FSW revealing violent acts by clients and other sex industry employees (bar owners, police, other FSW). The risk of violence by different types of persons associated with the sex work industry varied by venue and geographic area. Moreover, the violence was shaped by the social structural constraints of dominant gender ideologies. PMID:25409891
Factors associated with condom use among brothel-based female sex workers in Thailand.
Buckingham, R W; Moraros, J; Bird, Y; Meister, E; Webb, N C
2005-07-01
This study sought to determine the actual levels of condom use by female sex workers (FSW) in Thailand brothels. Specifically, it examined the influence that the country of origin of the FSW patrons exerted on usage of a condom, and it assessed the relevancy of constructs from the Health Belief Model in predicting FSW requesting condom usage by their clients. A survey was administered to a cross-sectional non-randomized convenience sample of 150 FSW in four geographic locations in Thailand, which included: Bangkok, Chang Mai, Mae Hong Son and Other (comprised mainly of brothels in small villages). Statistical interpretation of the data indicated that Thai FSW requested condom use in 63% of the cases, while the overall mean of condom use was only 51%. Condom use by patrons' country of origin was as follows: westerners 76%, foreign Asians 52% and native Thai men 27%. These results fall considerably short of the Ministry of Health's goal of 100% condom use in Thai brothels. Furthermore, public health education initiatives need to effectively target the native Thai FSW patrons since they represent the clients least likely to use a condom (27%).
The microstructure of aluminum A5083 butt joint by friction stir welding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jasri, M. A. H. M.; Afendi, M.; Ismail, A.
This study presents the microstructure of the aluminum A5083 butt joint surface after it has been joined by friction stir welding (FSW) process. The FSW process is a unique welding method because it will not change the chemical properties of the welded metals. In this study, MILKO 37 milling machine was modified to run FSW process on 4 mm plate of aluminum A5083 butt joint. For the experiment, variables of travel speed and tool rotational speed based on capability of machine were used to run FSW process. The concentrated heat from the tool to the aluminum plate changes the platemore » form from solid to plastic state. Two aluminum plates is merged to become one plate during plastic state and return to solid when concentrated heat is gradually further away. After that, the surface and cross section of the welded aluminum were investigated with a microscope by 400 x multiplication zoom. The welding defect in the FSW aluminum was identified. Then, the result was compared to the American Welding Society (AWS) FSW standard to decide whether the plate can be accepted or rejected.« less
Sexual and physical violence against female sex workers in Kenya: a qualitative enquiry.
Okal, Jerry; Chersich, Matthew F; Tsui, Sharon; Sutherland, Elizabeth; Temmerman, Marleen; Luchters, Stanley
2011-05-01
Few studies in Africa provide detailed descriptions of the vulnerabilities of female sex workers (FSW) to sexual and physical violence, and how this impacts on their HIV risk. This qualitative study documents FSW's experiences of violence in Mombasa and Naivasha, Kenya. Eighty-one FSW who obtained clients from the streets, transportation depots, taverns, discos and residential areas were recruited through local sex workers trained as peer counsellors to participate in eight focus-group discussions. Analysis showed the pervasiveness of sexual and physical violence among FSW, commonly triggered by negotiation around condoms and payment. Pressing financial needs of FSW, gender-power differentials, illegality of trading in sex and cultural subscriptions to men's entitlement for sex sans money underscore much of this violence. Sex workers with more experience had developed skills to avoid threats of violence by identifying potentially violent clients, finding safer working areas and minimising conflict with the police. Addressing violence and concomitant HIV risks and vulnerabilities faced by FSW should be included in Kenya's national HIV/AIDS strategic plan. This study indicates the need for multilevel interventions, including legal reforms so that laws governing sex work promote the health and human rights of sex workers in Kenya.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabooni, S., E-mail: s.sabooni@ma.iut.ac.ir; Karimzadeh, F.; Enayati, M.H.
In the present study, an ultrafine grained (UFG) AISI 304L stainless steel with the average grain size of 650 nm was successfully welded by both gas tungsten arc welding (GTAW) and friction stir welding (FSW). GTAW was applied without any filler metal. FSW was also performed at a constant rotational speed of 630 rpm and different welding speeds from 20 to 80 mm/min. Microstructural characterization was carried out by High Resolution Scanning Electron Microscopy (HRSEM) with Electron Backscattered Diffraction (EBSD) and Transmission Electron Microscopy (TEM). Nanoindentation, microhardness measurements and tensile tests were also performed to study the mechanical properties ofmore » the base metal and weldments. The results showed that the solidification mode in the GTAW welded sample is FA (ferrite–austenite) type with the microstructure consisting of an austenite matrix embedded with lath type and skeletal type ferrite. The nugget zone microstructure in the FSW welded samples consisted of equiaxed dynamically recrystallized austenite grains with some amount of elongated delta ferrite. Sigma phase precipitates were formed in the region ahead the rotating tool during the heating cycle of FSW, which were finally fragmented into nanometric particles and distributed in the weld nugget. Also there is a high possibility that the existing delta ferrite in the microstructure rapidly transforms into sigma phase particles during the short thermal cycle of FSW. These suggest that high strain and deformation during FSW can promote sigma phase formation. The final austenite grain size in the nugget zone was found to decrease with increasing Zener–Hollomon parameter, which was obtained quantitatively by measuring the peak temperature, calculating the strain rate during FSW and exact examination of hot deformation activation energy by considering the actual grain size before the occurrence of dynamic recrystallization. Mechanical properties observations showed that the welding efficiency of the FSW welded sample is around 70%, which is more than 20% higher than the GTAW welded sample. - Highlights: • Microstructure and mechanical properties of UFG 304L stainless steel were studied during GTAW and FSW. • Sigma phase formation mechanism was studied during FSW of 304L stainless steel. • THERMOCALC analysis was performed to obtain possible formation temperatures for sigma phase. • Nano-mechanical twins were found in the TMAZ region.« less
2007-02-28
Iterative Ultrasonic Signal and Image Deconvolution for Estimation of the Complex Medium Response, International Journal of Imaging Systems and...1767-1782, 2006. 31. Z. Mu, R. Plemmons, and P. Santago. Iterative Ultrasonic Signal and Image Deconvolution for Estimation of the Complex...rigorous mathematical and computational research on inverse problems in optical imaging of direct interest to the Army and also the intelligence agencies
Perkins, Richard W.; Fuller, James L.; Doctor, Steven R.; Good, Morris S.; Heasler, Patrick G.; Skorpik, James R.; Hansen, Norman H.
1995-01-01
The present invention is a means and method for identification and recognition of an item by ultrasonic imaging of material microfeatures and/or macrofeatures within the bulk volume of a material. The invention is based upon ultrasonic interrogation and imaging of material microfeatures within the body of material by accepting only reflected ultrasonic energy from a preselected plane or volume within the material. An initial interrogation produces an identification reference. Subsequent new scans are statistically compared to the identification reference for making a match/non-match decision.
Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy
NASA Technical Reports Server (NTRS)
Cantrell, Sean A.; Cantrell, John H.; Lilehei, Peter T.
2007-01-01
A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.
Perkins, R.W.; Fuller, J.L.; Doctor, S.R.; Good, M.S.; Heasler, P.G.; Skorpik, J.R.; Hansen, N.H.
1995-09-26
The present invention is a means and method for identification and recognition of an item by ultrasonic imaging of material microfeatures and/or macrofeatures within the bulk volume of a material. The invention is based upon ultrasonic interrogation and imaging of material microfeatures within the body of material by accepting only reflected ultrasonic energy from a preselected plane or volume within the material. An initial interrogation produces an identification reference. Subsequent new scans are statistically compared to the identification reference for making a match/non-match decision. 15 figs.
Application of Fuzzy Reasoning for Filtering and Enhancement of Ultrasonic Images
NASA Technical Reports Server (NTRS)
Sacha, J. P.; Cios, K. J.; Roth, D. J.; Berke, L.; Vary, A.
1994-01-01
This paper presents a new type of an adaptive fuzzy operator for detection of isolated abnormalities, and enhancement of raw ultrasonic images. Fuzzy sets used in decision rules are defined for each image based on empirical statistics of the color intensities. Examples of the method are also presented in the paper.
Development of Friction Stir Welding Technologies for In-Space Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Longhurst, William R.; Cox, Chase D.; Gibson, Brian T.
Friction stir welding (FSW) has emerged as an attractive process for fabricating aerospace vehicles. Current FSW state-of-the-art uses large machines that are not portable. However, there is a growing need for fabrication and repair operations associated with in-space manufacturing. This need stems from a desire for prolonged missions and travel beyond low-earth orbit. To address this need, research and development is presented regarding two enabling technologies. The first is a self-adjusting and aligning (SAA) FSW tool that drastically reduces the axial force that has historically been quite large. The SAA-FSW tool is a bobbin style tool that floats freely, withoutmore » any external actuators, along its vertical axis to adjust and align with the workpiece s position and orientation. Successful butt welding of 1/8 in. (3.175 mm) thick aluminum 1100 was achieved in conjunction with a drastic reduction and near elimination of the axial process force. Along with the SAA-FSW, an innovative in-process monitor technique is presented in which a magnetoelastic force rate-of-change sensor is employed. The sensor consists of a magnetized FSW tool that is used to induce a voltage in a coil surrounding the tool when changes to the process forces occur. The sensor was able to detect 1/16 in. (1.5875 mm) diameter voids. It is concluded that these technologies could be applied toward the development of a portable FSW machine for use in space.« less
Integrated bio-behavioural HIV surveillance surveys among female sex workers in Sudan, 2011-2012.
Elhadi, Magda; Elbadawi, Abdulateef; Abdelrahman, Samira; Mohammed, Ibtisam; Bozicevic, Ivana; Hassan, Ehab A; Elmukhtar, Mohammed; Ahmed, Sally; Abdelraheem, Mohammed Sidahmed; Mubarak, Nazik; Elsanousi, Salwa; Setayesh, Hamidreza
2013-11-01
To assess HIV and syphilis prevalence, HIV-related behaviours and testing for HIV in female sex workers (FSW) in Sudan. Bio-behavioural surveys using respondent-driven sampling were carried out among FSW in the capital cities of 14 states in Sudan in 2011-2012. HIV and syphilis testing was done by rapid tests. 4220 FSW aged 15-49 years were recruited. The median age of recruited women varied from 21 to 28 years per site. The highest HIV prevalence was measured at two sites in the eastern zone (5.0% and 7.7%), while in the other zones it ranged from 0% to 1.5%. Syphilis prevalence ranged from 1.5% in the northern zone to 8.9% in the eastern zone. Ever having been tested for HIV was reported by 4.4%-23.9% of FSW across all sites. Condom use at last sex with a client varied from 4.7% to 55.1%, while consistent condom use with clients in the month preceding the surveys was reported by 0.7%-24.5% of FSW. The highest reporting of ever injecting drugs was measured at a site in the western zone (5.0%). The surveys' findings indicate that the highest burden of HIV in FSW is in the eastern states of the country. Condom use and HIV testing data demonstrate the need for HIV interventions that should focus on HIV testing and risk reduction strategies that include stronger condom promotion programmes in FSW and their clients.
Development of Friction Stir Welding Technologies for In-Space Manufacturing
Longhurst, William R.; Cox, Chase D.; Gibson, Brian T.; ...
2016-08-26
Friction stir welding (FSW) has emerged as an attractive process for fabricating aerospace vehicles. Current FSW state-of-the-art uses large machines that are not portable. However, there is a growing need for fabrication and repair operations associated with in-space manufacturing. This need stems from a desire for prolonged missions and travel beyond low-earth orbit. To address this need, research and development is presented regarding two enabling technologies. The first is a self-adjusting and aligning (SAA) FSW tool that drastically reduces the axial force that has historically been quite large. The SAA-FSW tool is a bobbin style tool that floats freely, withoutmore » any external actuators, along its vertical axis to adjust and align with the workpiece s position and orientation. Successful butt welding of 1/8 in. (3.175 mm) thick aluminum 1100 was achieved in conjunction with a drastic reduction and near elimination of the axial process force. Along with the SAA-FSW, an innovative in-process monitor technique is presented in which a magnetoelastic force rate-of-change sensor is employed. The sensor consists of a magnetized FSW tool that is used to induce a voltage in a coil surrounding the tool when changes to the process forces occur. The sensor was able to detect 1/16 in. (1.5875 mm) diameter voids. It is concluded that these technologies could be applied toward the development of a portable FSW machine for use in space.« less
Friction Stir Welding of Line-Pipe Steels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanderson, Samuel; Mahoney, Murray; Feng, Zhili
Friction stir welding (FSW) offers both economic and technical advantages over conventional fusion welding practices for welding line-pipe. For offshore line-pipe construction, the economic savings has been shown to be considerable, approaching a calculated 25%. Offshore pipe is relatively small diameter but heavy wall compared to onshore pipe. One concern is the ability to achieve consistent full weld penetration in an on-site offshore FSW operation, e.g., on a lay-barge. In addition, depending on the size and morphology of the unwelded zone, lack of penetration at the weld root can be difficult if not impossible to detect by conventional NDE methods.more » Thus, an approach to assure consistent full penetration via process control is required for offshore line-pipe construction using FSW. For offshore construction, an internal structural mandrel can be used offering the opportunity to use a sacrificial anvil FSW approach. With this approach, a small volume of sacrificial material can be inserted into the structural anvil. The FSW tool penetrates into the sacrificial anvil, beyond the inner diameter of the pipe wall, thus assuring full penetration. The sacrificial material is subsequently removed from the pipe inner wall. In the work presented herein, FSW studies were completed on both 6 mm and 12 mm wall thickness line-pipe. Lastly, post-FSW evaluations including radiography, root-bend tests, and metallography demonstrated the merits of the sacrificial anvil approach to achieve consistent full penetration.« less
Cost effectiveness of targeted HIV prevention interventions for female sex workers in India.
Prinja, Shankar; Bahuguna, Pankaj; Rudra, Shalini; Gupta, Indrani; Kaur, Manmeet; Mehendale, S M; Chatterjee, Susmita; Panda, Samiran; Kumar, Rajesh
2011-06-01
To ascertain the cost effectiveness of targeted interventions for female sex workers (FSW) under the National AIDS Control Programme in India. A compartmental mathematical Markov state model was used over a 20-year time horizon (1995-2015) to estimate the cost effectiveness of FSW targeted interventions, with a health system perspective. The incremental costs and effects of FSW targeted interventions were compared against a baseline scenario of mass media for the general population alone. The incremental cost-effectiveness ratio was computed at a 3% discount rate using HIV infections averted and disability-adjusted life-years (DALY) as benefit measures. It was assumed that the transmission of the HIV virus moves from a high-risk group (FSW) to the client population and finally to the general population (partners of clients). Targeted interventions for FSW result in a reduction of 47% (1.6 million) prevalent and 36% (2.7 million) cumulative HIV cases, respectively, in 2015. Adult HIV prevalence in India, with and without (mass media only) FSW interventions, would be 0.25% and 0.48% in 2015. Indian government and development partners spend an average US $104 (INR4680) per HIV infection averted and US $10.7 (INR483) per DALY averted. Discounting at 3%, FSW targeted interventions cost US $105.5 (INR4748) and US $10.9 (INR490) per HIV case and DALY averted, respectively. At the current gross domestic product in India, targeted intervention is a cost-effective strategy for HIV prevention in India.
Piezoelectric single crystals for ultrasonic transducers in biomedical applications
Zhou, Qifa; Lam, Kwok Ho; Zheng, Hairong; Qiu, Weibao; Shung, K. Kirk
2014-01-01
Piezoelectric single crystals, which have excellent piezoelectric properties, have extensively been employed for various sensors and actuators applications. In this paper, the state–of–art in piezoelectric single crystals for ultrasonic transducer applications is reviewed. Firstly, the basic principles and design considerations of piezoelectric ultrasonic transducers will be addressed. Then, the popular piezoelectric single crystals used for ultrasonic transducer applications, including LiNbO3 (LN), PMN–PT and PIN–PMN–PT, will be introduced. After describing the preparation and performance of the single crystals, the recent development of both the single–element and array transducers fabricated using the single crystals will be presented. Finally, various biomedical applications including eye imaging, intravascular imaging, blood flow measurement, photoacoustic imaging, and microbeam applications of the single crystal transducers will be discussed. PMID:25386032
Sherwood, Jennifer A; Grosso, Ashley; Decker, Michele R; Peitzmeier, Sarah; Papworth, Erin; Diouf, Daouda; Drame, Fatou Maria; Ceesay, Nuha; Baral, Stefan
2015-03-19
Female sex workers (FSW) are a vulnerable population for sexual violence and poor sexual and reproductive health outcomes. Sexual violence against FSW has not been widely studied in The Gambia. This study will report the prevalence of and evaluate the health issues correlated with forced sex perpetrated by clients against FSW in The Gambia, and will secondly aim to inform future research and efforts to improve health outcomes for survivors of violence. A cross-sectional survey was administered among 251 FSW accrued through a combination of chain referral and venue-based sampling in The Gambia. Eligibility criteria included being over 16 years old and having exchanged sex for money, goods, or favors in the past 12 months. There is a high prevalence of sexual violence against FSW in The Gambia, with 29% (n = 70) of participants reporting a client forced them to have sex in their lifetime. Women who reported forced sex by a client were more likely to report symptoms of depression (aOR 2.15, CI: 1.10-4.16 p < 0.05), unwanted pregnancy (aOR: 2.69, CI: 1.12-6.49 p < 0.05) and report "no", "difficult" or "somewhat difficult" access to condoms (aOR: 3.31, CI: 1.76-6.26 p < .01) compared to women who did not report forced sex. Client-perpetrated forced sex was also negatively associated with receiving any sexually transmitted infection (STI) test in the past 12 months (aOR: 0.49, CI: .26-.91 p < .05). FSW who experience sexual violence by a client are more likely to experience poor sexual, reproductive and mental health outcomes. Responding to sexual violence among FSW, including providing survivors with access to post-exposure prophylaxis, emergency contraception, and mental health services, must be a priority given the prevalence of forced sex and links with poor health outcomes. Efforts to reduce sexual violence against FSW is a vital strategy to improve the health and safety of FSW as well as impact the spread of HIV/STIs in The Gambia.
Automatic Quadcopter Control Avoiding Obstacle Using Camera with Integrated Ultrasonic Sensor
NASA Astrophysics Data System (ADS)
Anis, Hanafi; Haris Indra Fadhillah, Ahmad; Darma, Surya; Soekirno, Santoso
2018-04-01
Automatic navigation on the drone is being developed these days, a wide variety of types of drones and its automatic functions. Drones used in this study was an aircraft with four propellers or quadcopter. In this experiment, image processing used to recognize the position of an object and ultrasonic sensor used to detect obstacle distance. The method used to trace an obsctacle in image processing was the Lucas-Kanade-Tomasi Tracker, which had been widely used due to its high accuracy. Ultrasonic sensor used to complement the image processing success rate to be fully detected object. The obstacle avoidance system was to observe at the program decisions from some obstacle conditions read by the camera and ultrasonic sensors. Visual feedback control based PID controllers are used as a control of drones movement. The conclusion of the obstacle avoidance system was to observe at the program decisions from some obstacle conditions read by the camera and ultrasonic sensors.
An initial investigation into pseudo-coloring for ultrasonic NDE of polycrystalline materials
NASA Astrophysics Data System (ADS)
Van Pamel, A.; Brett, C. R.; Lowe, M. J. S.
2015-03-01
Ultrasonic imaging for NDE is limited by the challenge of detection, which relies on discriminating between objects based on their intensity. Whilst this works well in ultrasonically transparent media, in polycrystalline materials however, a host where scatterers are abundant, this is no longer the case. In such media, intensity information, as a means of interpreting an image, is compromised by the background of coherent microstructural noise. In a bid to improve this, it is suggested here to use pseudo-coloring to consider frequency information and distinguish objects based on their emitted frequency spectra. This approach exploits the frequency diversity; namely the difference in frequency dependence of the noise stemming from the material's microstructure, or backscatter, and that exhibited by the targets of interest: defects. Whereas established frequency diversity techniques exploit this additional information to reconvert it into amplitude data, color enables encoding frequency and intensity information independently. This article serves as an initial exploration of pseudo-coloring ultrasonic images for ultrasonic NDE of polycrystalline materials.
Improved Ultrasonic Imaging of the Breast
2003-08-01
benign and malignant masses often exhibit only subtle image differences. We have invented a new technique that uses modified ultrasound equipment to form images of ultrasonic angular scatter. This method provides a new source of image contrast and should enhance the detectability of MCs and improve the differentiation of benign and malignant lesions. This method yields high resolution images with minimal statistical variability. In this first year 0 funding, we have formed images in tissue mimicking phantoms and found that
High Resolution X-Ray Phase Contrast Imaging with Acoustic Tissue-Selective Contrast Enhancement
2005-06-01
Ultrasonics Symp 1319 (1999). 17. Sarvazyan, A. P. Shear Wave Elasticity Imaging: A New Ultrasonic Technology of Medical Diagnostics. Ultrasound in...samples using acoustically modulated X-ray phase contrast imaging. 15. SUBJECT TERMS x-ray, ultrasound, phase contrast, imaging, elastography 16...x-rays, phase contrast imaging is based on phase changes as x-rays traverse a body resulting in wave interference that result in intensity changes in
Considerations for ultrasonic testing application for on-orbit NDE
NASA Astrophysics Data System (ADS)
Koshti, Ajay M.
2015-04-01
The paper addresses some on-orbit nondestructive evaluation (NDE) needs of NASA for International Space Station (ISS). The presentation gives NDE requirements for inspecting suspect damage due to micro-meteoroids and orbital debris (MMOD) impact on the pressure wall of the ISS. This inspection is meant to be conducted from inside of the ISS module. The metallic wall of the module has a fixed wall thickness but also has integral orthogrid ribs for reinforcement. Typically, a single MMOD hit causes localized damage in a small area causing loss of material similar to pitting corrosion, but cracks may be present too. The impact may cause bulging of the wall. Results of the ultrasonic and eddy current demonstration scans on test samples are provided. The ultrasonic technique uses shear wave scans to interrogate the localized damage area from the surrounding undamaged area. The scanning protocol results in multiple scans, each with multiple "vee" paths. A superimposition and mosaic of the three-dimensional ultrasonic data from individual scans is desired to create C-scan images of the damage. This is a new data reduction process which is not currently implemented in state-of-art ultrasonic instruments. Results of ultrasonic scans on the simulated MMOD damage test plates are provided. The individual C-scans are superimposed manually creating mosaic of the inspection. The resulting image is compared with visibly detected damage boundaries, X-ray images, and localized ultrasonic and eddy current scans for locating crack tips to assess effectiveness of the ultrasonic scanning. The paper also discusses developments needed in improving ergonomics of the ultrasonic testing for on-orbit applications.
A border context of violence: Mexican female sex workers on the U.S.-Mexico border.
Cepeda, Alice; Nowotny, Kathryn M
2014-12-01
Female sex workers (FSW) represent a population confronted with an array of intersecting social problems. We explore the case of FSW in Nuevo Laredo and Ciudad Juarez to understand the everyday violence associated with sex work within the unique context of Mexico. Life history interviews were conducted with 109 FSW revealing violent acts by clients and other sex industry employees (bar owners, police, other FSW). The risk of violence by different types of persons associated with the sex work industry varied by venue and geographic area. Moreover, the violence was shaped by the social structural constraints of dominant gender ideologies. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Horton, Karla Renee
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. This work reports on material properties and strain patterns developed in a SR-FSW with a friction plug weld. Specifically, this study examines the behavior of a SR-FSW formed between an AA2014-T6 plate on the advancing side and an AA2219-T87 plate on the retreating side and a SR-FSW (AA2014-T6 to AA2219-T87) with a 2219-T87 plug weld. This study presents the results of a characterization of the micro-hardness, joint strength, and strain field characterization of SR-FSW and FPW joints tested at room temperature and cryogenic temperatures. The initial weld microstructure analysis showed a nugget region with fine grains and a displaced weld seam from the advancing side past the thermo-mechanical affected zone (TMAZ) into the nugget region. The displaced material shared the same hardness as the parent material. Dynamic recrystallization was observed in the SR-FSW zone and the displaced weld seam region. The welds revealed a fine grain structure in the SR-FSW zone with a sharp demarcation seen on the advancing side and fairly diffuse flow observed on the retreating side. The parent material hardness is 145 HV700g with a drop in hardness starting at the HAZ to 130 HV700g. The hardness further drops in the TMAZ to118 HV700g with an increase representing a dispersed interface of AA2014-T6 material to 135 HV700g. The hardness then drops significantly within the nugget region to 85 HV700g followed by an increase through the retreating side TMAZ into the HAZ to 135 HV 700g. There was a sharp increase in the hardness value within the nugget region with the samples that were PWHT showing an increase of 58%. The welded joints were tested for ultimate strength. The testing variations included two specimen widths, two plug sizes (M3 and M5), room temperature and cryogenic testing, and post weld heat treated (PWHT) samples. Initial welds had an average ultimate strength of 370 MPa. There was a slight drop from initial weld strength to plug weld strength of approximately 13.8 MPa was observed with M3 plug strength approximately equal to M5 plug strength. The PWHT strengths at room temperature were slightly higher than non-PWHT of 13.8--20.7 MPa and PWHT strengths were equal to non-PWHT at cryogenic temperature. Non-PWHT had a cryogenic strength enhancement approximately 59.2 MPa and PWHT had a cryogenic strength enhancement of approximately 57.2 MPa in the M3 and M5 plugs. Within the subsets of data collected no major statistical significance in strength behavior was observed between the samples tested at room temperature or between the subsets tested at LN2. In almost all cases, failure occurred on the retreating side of the weld which corresponds to the softer material (AA2219-T87). Exceptions were characterized with flaws (weld defects) in the sample. In these cases, failure occurred on the advancing side, the side where flaws were detected. Ductile fracture was noted in most all samples. Digital image correlation using the ARAMIS system was used to define strain patterns in the weld joint. Strain accumulation was observed in the weld along the retreating side and around the plug. ARAMIS data in comparison to extensometer data shows a very reasonable comparison. The ARAMIS strain gage data showed the retreating side of the major diameter has a greater yield than the advancing side. This behavior is identical to the external electrical resistance strain gages.
Strategies for recruiting steady male partners of female sex workers for HIV research
Fleming, Paul J.; Barrington, Clare; Perez, Martha; Donastorg, Yeycy; Kerrigan, Deanna
2014-01-01
Steady male partners of female sex workers (FSW) are a key population for HIV prevention, but researchers face challenges finding and recruiting this population. We conducted forty in-depth interviews with FSW and steady male partners of FSW in Santo Domingo, Dominican Republic about how to engage steady male partners in HIV research. Participants cautioned that male partners might be unwilling to participate because of discomfort disclosing intimate information and cultural norms of masculinity. They recommended inviting male partners to research offices, instead of venue-based recruitment, because it was more private and trust-promoting. Most participants suggested that FSW could refer their partners or men could refer their friends who have FSW partners. Participants emphasized that referrals could break down trust-related barriers that prevent male partners from participating. Establishing an environment of respect and trust in the research setting can aid referral processes as individuals who participate communicate their positive experiences to their networks. PMID:25192901
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Wei; Chen, Gaoqiang; Chen, Jian
Reduced-activation ferritic/martensitic (RAFM) steels are an important class of structural materials for fusion reactor internals developed in recent years because of their improved irradiation resistance. However, they can suffer from welding induced property degradations. In this paper, a solid phase joining technology friction stir welding (FSW) was adopted to join a RAFM steel Eurofer 97 and different FSW parameters/heat input were chosen to produce welds. FSW response parameters, joint microstructures and microhardness were investigated to reveal relationships among welding heat input, weld structure characterization and mechanical properties. In general, FSW heat input results in high hardness inside the stir zonemore » mostly due to a martensitic transformation. It is possible to produce friction stir welds similar to but not with exactly the same base metal hardness when using low power input because of other hardening mechanisms. Further, post weld heat treatment (PWHT) is a very effective way to reduce FSW stir zone hardness values.« less
Emission of nanoparticles during friction stir welding (FSW) of aluminium alloys.
Gomes, J F; Miranda, R M; Santos, T J; Carvalho, P A
2014-01-01
Friction stir welding (FSW) is now well established as a welding process capable of joining some different types of metallic materials, as it was (1) found to be a reliable and economical way of producing high quality welds, and (2) considered a "clean" welding process that does not involve fusion of metal, as is the case with other traditional welding processes. The aim of this study was to determine whether the emission of particles during FSW in the nanorange of the most commonly used aluminum (Al) alloys, AA 5083 and AA 6082, originated from the Al alloy itself due to friction of the welding tool against the item that was being welded. Another goal was to measure Al alloys in the alveolar deposited surface area during FSW. Nanoparticles dimensions were predominantly in the 40- and 70-nm range. This study demonstrated that microparticles were also emitted during FSW but due to tool wear. However, the biological relevance and toxic manifestations of these microparticles remain to be determined.
NASA Astrophysics Data System (ADS)
Nogo, Kosuke; Mori, Keita; Qi, Wei; Hosono, Satsuki; Kawashima, Natsumi; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro
2016-03-01
We proposed the ultrasonic-assisted spectroscopic imaging for the realization of blood-glucose-level monitoring during dialytic therapy. Optical scattering and absorption caused by blood cells deteriorate the detection accuracy of glucose dissolved in plasma. Ultrasonic standing waves can agglomerate blood cells at nodes. In contrast, around anti-node regions, the amount of transmitted light increases because relatively clear plasma appears due to decline the number of blood cells. Proposed method can disperse the transmitted light of plasma without time-consuming pretreatment such as centrifugation. To realize the thumb-size glucose sensor which can be easily attached to dialysis tubes, an ultrasonic standing wave generator and a spectroscopic imager are required to be small. Ultrasonic oscillators are ∅30[mm]. A drive circuit of oscillators, which now size is 41×55×45[mm], is expected to become small. The trial apparatus of proposed one-shot Fourier spectroscopic imager, whose size is 30×30×48[mm], also can be little-finger size in principal. In the experiment, we separated the suspension mixed water and micro spheres (Θ10[mm) into particles and liquid regions with the ultrasonic standing wave (frequency: 2[MHz]). Furthermore, the spectrum of transmitted light through the suspension could be obtained in visible light regions with a white LED.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Hendricks, J. Lynne; Whalen, Mike F.; Bodis, James R.; Martin, Katherine
1996-01-01
This article describes the commercial implementation of ultrasonic velocity imaging methods developed and refined at NASA Lewis Research Center on the Sonix c-scan inspection system. Two velocity imaging methods were implemented: thickness-based and non-thickness-based reflector plate methods. The article demonstrates capabilities of the commercial implementation and gives the detailed operating procedures required for Sonix customers to achieve optimum velocity imaging results. This commercial implementation of velocity imaging provides a 100x speed increase in scanning and processing over the lab-based methods developed at LeRC. The significance of this cooperative effort is that the aerospace and other materials development-intensive industries which use extensive ultrasonic inspection for process control and failure analysis will now have an alternative, highly accurate imaging method commercially available.
Friction Stir Weld Restart+Reweld Repair Allowables
NASA Technical Reports Server (NTRS)
Clifton, Andrew
2008-01-01
A friction stir weld (FSW) repair method has been developed and successfully implemented on Al 2195 plate material for the Space Shuttle External Fuel Tank (ET). The method includes restarting the friction stir weld in the termination hole of the original weld followed by two reweld passes. Room temperature and cryogenic temperature mechanical properties exceeded minimum FSW design strength and compared well with the development data. Simulated service test results also compared closely to historical data for initial FSW, confirming no change to the critical flaw size or inspection requirements for the repaired weld. Testing of VPPA fusion/FSW intersection weld specimens exhibited acceptable strength and exceeded the minimum design value. Porosity, when present at the intersection was on the root side toe of the fusion weld, the "worst case" being 0.7 inch long. While such porosity may be removed by sanding, this "worst case" porosity condition was tested "as is" and demonstrated that porosity did not negatively affect the strength of the intersection weld. Large, 15-inch "wide panels" FSW repair welds were tested to demonstrate strength and evaluate residual stresses using photo stress analysis. All results exceeded design minimums, and photo stress analysis showed no significant stress gradients due to the presence of the restart and multi-pass FSW repair weld.
Mechanical Properties and Microstructure of TIG and FSW Joints of a New Al-Mg-Mn-Sc-Zr Alloy
NASA Astrophysics Data System (ADS)
Xu, Guofu; Qian, Jian; Xiao, Dan; Deng, Ying; Lu, Liying; Yin, Zhimin
2016-04-01
A new Al-5.8%Mg-0.4%Mn-0.25%Sc-0.10%Zr (wt.%) alloy was successfully welded by tungsten inert gas (TIG) and friction stir welding (FSW) techniques, respectively. The mechanical properties and microstructure of the welded joints were investigated by microhardness measurements, tensile tests, and microscopy methods. The results show that the ultimate tensile strength, yield strength, and elongation to failure are 358, 234 MPa, and 27.6% for TIG welded joint, and 376, 245 MPa and 31.9% for FSW joint, respectively, showing high strength and superior ductility. The TIG welded joint fails in the heat-affected zone and the fracture of FSW joint is located in stirred zone. Al-Mg-Mn-Sc-Zr alloy is characterized by lots of dislocation tangles and secondary coherent Al3(Sc,Zr) particles. The superior mechanical properties of the TIG and FSW joints are mainly derived from the Orowan strengthening and grain boundary strengthening caused by secondary coherent Al3(Sc,Zr) nano-particles (20-40 nm). For new Al-Mg-Mn-Sc-Zr alloy, the positive effect from secondary Al3(Sc, Zr) particles in the base metal can be better preserved in FSW joint than in TIG welded joint.
Barriers to Follow-Up for Abnormal Papanicolaou Smears among Female Sex Workers in Lima, Peru.
Aharon, Devora; Calderon, Martha; Solari, Vicky; Alarcon, Patricia; Zunt, Joseph
2017-01-01
Cervical cancer is the most prevalent cancer among Peruvian women. Female sex workers (FSW) in Peru are at elevated risk for HPV infection, and receive annual Papanicolaou screening. The objective of this study was to identify barriers to follow-up for abnormal Pap smears among FSW in Peru. 97 FSW attending the Alberto Barton Health Center in Lima were surveyed regarding their STI screening history. 17 women with a history of an abnormal Pap smear were interviewed about their experiences regarding follow-up care. Of the 27 HPV-positive women, only 8 (30%) received follow-up treatment. Of the 19 women who did not receive follow-up, 7 (37%) had not been informed of their abnormal result. Qualitative interviews revealed that the major barrier to follow-up was lack of knowledge about HPV and potential health consequences of an abnormal Pap smear. HPV infection is highly prevalent in Peruvian FSW, yet only 30% of FSW with abnormal Pap smears receive follow-up care. The predominant barriers to follow-up were lack of standardization in recording and communicating results and insufficient FSW knowledge regarding health consequences of HPV infection. Standardization of record-keeping and distribution of educational pamphlets have been implemented to improve follow-up for HPV.
NASA Technical Reports Server (NTRS)
Miller, James G.
1995-01-01
In this Progress Report, the author describes the continuing research to explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize complex materials. Images obtained using an unmodified medical ultrasonic imaging system of a bonded aluminum plate sample with a simulated disbond region are presented. The disbond region was produced by adhering a piece of plain white paper to a piece of cellophane tape and applying the paper-tape combination to one of the aluminum plates. Because the area under the paper was not adhesively bonded to the aluminum plate, this arrangement more closely simulates a disbond. Images are also presented for an aluminum plate sample with an epoxy strip adhered to one side to help provide information for the interpretation of the images of the bonded aluminum plate sample containing the disbond region. These images are compared with corresponding conventional ultrasonic contact transducer measurements in order to provide information regarding the nature of the disbonded region. The results of this on-going investigation may provide a step toward the development of a rapid, real-time, and portable method of ultrasonic inspection and characterization based on linear array technology. In Section 2 of this Progress Report, the preparation of the aluminum plate specimens is described. Section 3 describes the method of linear array imaging. Sections 4 and 5 present the linear array images and results from contact transducer measurements, respectively. A discussion of the results are presented in Section 6.
Lancaster, Kathryn E; Cernigliaro, Dana; Zulliger, Rose; Fleming, Paul F
2016-12-01
Female sex workers (FSW) living with HIV in sub-Saharan Africa have poor engagement to HIV care and treatment. Understanding the HIV care and treatment engagement experiences of FSW has important implications for interventions to enhance care and treatment outcomes. We conducted a systematic review to examine the HIV care experiences and determinants of linkage and retention in care, antiretroviral therapy (ART) initiation, and ART adherence and viral suppression among FSW living with HIV in sub-Saharan Africa. The databases PubMed, Embase, Web of Science, SCOPUS, CINAHL, Global Health, Psycinfo, Sociological Abstracts, and Popline were searched for variations of search terms related to sex work and HIV care and treatment among sub-Saharan African populations. Ten peer-reviewed articles published between January 2000 and August 2015 met inclusion criteria and were included in this review. Despite expanded ART access, FSW in sub-Saharan Africa have sub-optimal HIV care and treatment engagement outcomes. Stigma, discrimination, poor nutrition, food insecurity, and substance use were commonly reported and associated with poor linkage to care, retention in care, and ART initiation. Included studies suggest that interventions with FSW should focus on multilevel barriers to engagement in HIV care and treatment and explore the involvement of social support from intimate male partners. Our results emphasise several critical points of intervention for FSW living with HIV, which are urgently needed to enhance linkage to HIV care, retention in care, and treatment initiation, particularly where the HIV prevalence among FSW is greatest.
Destructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities
Guan, Liming; Xu, Gang
2017-01-01
Objectives To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. Materials and Methods Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbits before and after ultrasonic ablation were observed after autopsy. The slides were used for hematoxylin-eosin staining, elastic fiber staining and endothelial cell staining; the slides were observed by optical microscopy. One slide was observed by electron microscopy. Then the target lesions of experimental animals with ultrasonic ablation were observed by vascular imaging, one group was visualized by digital subtract angiography, one group was quantified by color Doppler flow imaging, and one group was detected by dye perfusion. SPSS 19.0 software was used for statistical analyses. Results Histological examination indicated that High-intensity focused ultrasound caused the tumor tissues and their vascularities coagulative necrosis. Tumor vascular structure components including elastic fiber, endothelial cells all were destroyed by ultrasonic ablation. Digital subtract angiography showed tumor vascular shadow were dismissed after ultrasonic ablation. After ultrasonic ablation, gray-scale of tumor nodules enhanced in ultrasonography, tumor peripheral and internal blood flow signals disappeared or significantly reduced in color Doppler flow imaging. Vascular perfusion performed after ultrasonic ablation, tumor vessels could not filled by dye liquid. Conclusion High-intensity focused ultrasound as a noninvasive method can destroy whole endometrial cancer cells and their supplying vascularities, which maybe an alternative approach of targeted therapy and new antiangiogenic strategy for endometrial cancer. PMID:28121624
Destructive effect of HIFU on rabbit embedded endometrial carcinoma tissues and their vascularities.
Guan, Liming; Xu, Gang
2017-03-21
To evaluate damage effect of High-intensity focused ultrasound on early stage endometrial cancer tissues and their vascularities. Rabbit endometrial cancer models were established via tumor blocks implantation for a prospective control study. Ultrasonic ablation efficacy was evaluated by pathologic and imaging changes. The target lesions of experimental rabbits before and after ultrasonic ablation were observed after autopsy. The slides were used for hematoxylin-eosin staining, elastic fiber staining and endothelial cell staining; the slides were observed by optical microscopy. One slide was observed by electron microscopy. Then the target lesions of experimental animals with ultrasonic ablation were observed by vascular imaging, one group was visualized by digital subtract angiography, one group was quantified by color Doppler flow imaging, and one group was detected by dye perfusion.SPSS 19.0 software was used for statistical analyses. Histological examination indicated that High-intensity focused ultrasound caused the tumor tissues and their vascularities coagulative necrosis. Tumor vascular structure components including elastic fiber, endothelial cells all were destroyed by ultrasonic ablation. Digital subtract angiography showed tumor vascular shadow were dismissed after ultrasonic ablation. After ultrasonic ablation, gray-scale of tumor nodules enhanced in ultrasonography, tumor peripheral and internal blood flow signals disappeared or significantly reduced in color Doppler flow imaging. Vascular perfusion performed after ultrasonic ablation, tumor vessels could not filled by dye liquid. High-intensity focused ultrasound as a noninvasive method can destroy whole endometrial cancer cells and their supplying vascularities, which maybe an alternative approach of targeted therapy and new antiangiogenic strategy for endometrial cancer.
NASA Technical Reports Server (NTRS)
Smith, Barry T.
1990-01-01
Damage in composite materials was studied with through-the-thickness reinforcements. As a first step it was necessary to develop new ultrasonic imaging technology to better assess internal damage of the composite. A useful ultrasonic imaging technique was successfully developed to assess the internal damage of composite panels. The ultrasonic technique accurately determines the size of the internal damage. It was found that the ultrasonic imaging technique was better able to assess the damage in a composite panel with through-the-thickness reinforcements than by destructively sectioning the specimen and visual inspection under a microscope. Five composite compression-after-impact panels were tested. The compression-after-impact strength of the panels with the through-the-thickness reinforcements was almost twice that of the comparable panel without through-the-thickness reinforcement.
NASA Technical Reports Server (NTRS)
McComas, David
2013-01-01
The flight software (FSW) math library is a collection of reusable math components that provides typical math utilities required by spacecraft flight software. These utilities are intended to increase flight software quality reusability and maintainability by providing a set of consistent, well-documented, and tested math utilities. This library only has dependencies on ANSI C, so it is easily ported. Prior to this library, each mission typically created its own math utilities using ideas/code from previous missions. Part of the reason for this is that math libraries can be written with different strategies in areas like error handling, parameters orders, naming conventions, etc. Changing the utilities for each mission introduces risks and costs. The obvious risks and costs are that the utilities must be coded and revalidated. The hidden risks and costs arise in miscommunication between engineers. These utilities must be understood by both the flight software engineers and other subsystem engineers (primarily guidance navigation and control). The FSW math library is part of a larger goal to produce a library of reusable Guidance Navigation and Control (GN&C) FSW components. A GN&C FSW library cannot be created unless a standardized math basis is created. This library solves the standardization problem by defining a common feature set and establishing policies for the library s design. This allows the libraries to be maintained with the same strategy used in its initial development, which supports a library of reusable GN&C FSW components. The FSW math library is written for an embedded software environment in C. This places restrictions on the language features that can be used by the library. Another advantage of the FSW math library is that it can be used in the FSW as well as other environments like the GN&C analyst s simulators. This helps communication between the teams because they can use the same utilities with the same feature set and syntax.
Ramesh, B M; Beattie, Tara S H; Shajy, Isac; Washington, Reynold; Jagannathan, Latta; Reza-Paul, Sushena; Blanchard, James F; Moses, Stephen
2010-02-01
To examine the impact of a large-scale HIV prevention programme for female sex workers (FSW) in Karnataka state, south India, on the prevalence of HIV/sexually transmitted infections (STI), condom use and programme coverage. Baseline and follow-up integrated biological and behavioural surveys were conducted on random samples of FSW in five districts in Karnataka between 2004 and 2009. 4712 FSW participated in the study (baseline 2312; follow-up 2400), with follow-up surveys conducted 28-37 months after baseline. By follow-up, over 85% of FSW reported contact by a peer educator and having visited a project STI clinic. Compared with baseline, there were reductions in the prevalence of HIV (19.6% vs 16.4%, adjusted odds ratio (AOR) 0.81, 95% CI 0.67 to 0.99, p=0.04); high-titre syphilis (5.9% vs 3.4%, AOR 0.53, 95% CI 0.37 to 0.77, p=0.001); and chlamydia and/or gonorrhoea (8.9% vs 7.0%, AOR 0.72, 95% CI 0.54 to 0.94, p=0.02). Reported condom use at last sex increased significantly for repeat clients (66.1% vs 84.1%, AOR 1.98, 95% CI 1.58 to 2.48, p<0.001) and marginally for occasional clients (82.9% vs 88.0%, AOR 1.22, 95% CI 0.89 to 1.66, p=0.2), but remained stable for regular partners (32%). Compared with street and home-based FSW, brothel-based FSW were at highest risk of HIV and STI, despite high levels of reported condom use. This large-scale HIV prevention programme for FSW achieved reductions in HIV and STI prevalence, high rates of condom use with clients and high rates of programme coverage. Improved strategies to increase condom use with regular partners and reduce the vulnerability of brothel-based FSW to HIV are required.
Micheni, Murugi; Rogers, Sam; Wahome, Elizabeth; Darwinkel, Marianne; van der Elst, Elise; Gichuru, Evans; Graham, Susan M.; Sanders, Eduard J.; Smith, Adrian D.
2016-01-01
Background Violence toward MSM and female sex workers (FSW) is associated with HIV risk, and its prevention is prioritized in international HIV/AIDS policy. Methods Sociodemographic and behavioural data derived from HIV risk and follow-up cohorts including MSM and FSW in coastal Kenya between 2005 and 2014 was used to estimate the risk of rape, physical assault and verbal abuse, and to assess associations between first occurrence of assault with individual and recent behavioural factors. Results Incidence of first reported rape was similar for MSM [3.9, confidence interval (CI) 3.1–5.0 per 100 person-years (pyrs)] and FSW (4.8 CI 3.5–6.4 per 100 pyrs), P =0.22. Incidence of first reported physical and verbal assault was higher for FSW than MSM (21.1 versus 12.9 per 100 pyrs, P =0.14 and 51.3 versus 30.9 per 100 pyrs, P =0.03 respectively). Recent alcohol use was associated with reporting of all forms of assault by MSM [adjusted odds ratio (AOR) 1.8, CI 0.9–3.5] and FSW (AOR 4.4, CI 1.41–14.0), as was recent sale of sex for MSM (AOR 2.0, CI 1.1–3.8). Exclusive sex with men, active sex work, and group sex were also specifically associated with reporting rape for MSM. Perpetrators of sexual and verbal assault were usually unknown, whilst perpetrators of physical violence toward FSW were usually regular sexual partners. Conclusion MSM and FSW experienced a similarly high incidence of sexual assault in coastal Kenya, in addition to physical and verbal assault. Current national policies focus heavily on gender-based violence against women and young girls, but need to be inclusive of MSM and FSW. PMID:26562812
NASA Technical Reports Server (NTRS)
Ding, Jeff; Carter, Bob; Lawless, Kirby; Nunes, Arthur; Russell, Carolyn; Suites, Michael; Schneider, Judy
2006-01-01
Welding at NASA's Marshall Space Flight Center (MSFC), Huntsville, Alabama, has taken a new direction through the last 10 years. Fusion welding processes, namely variable polarity plasma arc (VPPA) and tungsten inert gas (TIG) were once the corner stone of welding development in the Space Flight Center's welding laboratories, located in the part of MSFC know as National Center for Advanced Manufacturing (NCM). Developed specifically to support the Shuttle Program's External Tank and later International Space Station manufacturing programs, was viewed as the paragon of welding processes for joining aluminum alloys. Much has changed since 1994, however, when NASA's Jeff Ding brought the FSW process to the NASA agency. Although, at that time, FSW was little more than a "lab curiosity", NASA researchers started investigating where the FSW process would best fit NASA manufacturing programs. A laboratory FSW system was procured and the first welds were made in fall of 1995. The small initial investment NASA made into the first FSW system has certainly paid off for the NASA agency in terms of cost savings, hardware quality and notoriety. FSW is now a part of Shuttle External Tank (ET) production and the preferred weld process for the manufacturing of components for the new Crew Launch Vehicle (CLV) and Heavy Lift Launch Vehicle (HLLV) that will take this country back to the moon. It is one of the solid state welding processes being considered for on-orbit space welding and repair, and is of considerable interest for Department of Defense @OD) manufacturing programs. MSFC involvement in these and other programs makes NASA a driving force in this country's development of FSW and other solid state welding technologies. Now, a decade later, almost the entire on-going welding R&D at MSFC now focuses on FSW and other more advanced solid state welding processes.
Ultrasonically modulated x-ray phase contrast and vibration potential imaging methods
NASA Astrophysics Data System (ADS)
Hamilton, Theron J.; Cao, Guohua; Wang, Shougang; Bailat, Claude J.; Nguyen, Cuong K.; Li, Shengqiong; Gehring, Stephan; Wands, Jack; Gusev, Vitalyi; Rose-Petruck, Christoph; Diebold, Gerald J.
2006-02-01
We show that the radiation pressure exerted by a beam of ultrasound can be used for contrast enhancement in high resolution x-ray imaging of tissue. Interfacial features of objects are highlighted as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. The potential of the method is demonstrated by imaging various tumor phantoms and tumors from mice. The directionality of the acoustic radiation force and its localization in space permits the imaging of ultrasound-selected tissue volumes. In a related effort we report progress on development of an imaging technique using and electrokinetic effect known as the ultrasonic vibration potential. The ultrasonic vibration potential refers to the voltage generated when ultrasound traverses a colloidal or ionic fluid. The theory of imaging based on the vibration potential is reviewed, and an expression given that describes the signal from an arbitrary object. The experimental apparatus consists of a pair of parallel plates connected to the irradiated body, a low noise preamplifier, a radio frequency lock-in amplifier, translation stages for the ultrasonic transducer that generates the ultrasound, and a computer for data storage and image formation. Experiments are reported where bursts of ultrasound are directed onto colloidal silica objects placed within inert bodies.
A versatile nondestructive evaluation imaging workstation
NASA Technical Reports Server (NTRS)
Chern, E. James; Butler, David W.
1994-01-01
Ultrasonic C-scan and eddy current imaging systems are of the pointwise type evaluation systems that rely on a mechanical scanner to physically maneuver a probe relative to the specimen point by point in order to acquire data and generate images. Since the ultrasonic C-scan and eddy current imaging systems are based on the same mechanical scanning mechanisms, the two systems can be combined using the same PC platform with a common mechanical manipulation subsystem and integrated data acquisition software. Based on this concept, we have developed an IBM PC-based combined ultrasonic C-scan and eddy current imaging system. The system is modularized and provides capacity for future hardware and software expansions. Advantages associated with the combined system are: (1) eliminated duplication of the computer and mechanical hardware, (2) unified data acquisition, processing and storage software, (3) reduced setup time for repetitious ultrasonic and eddy current scans, and (4) improved system efficiency. The concept can be adapted to many engineering systems by integrating related PC-based instruments into one multipurpose workstation such as dispensing, machining, packaging, sorting, and other industrial applications.
A versatile nondestructive evaluation imaging workstation
NASA Astrophysics Data System (ADS)
Chern, E. James; Butler, David W.
1994-02-01
Ultrasonic C-scan and eddy current imaging systems are of the pointwise type evaluation systems that rely on a mechanical scanner to physically maneuver a probe relative to the specimen point by point in order to acquire data and generate images. Since the ultrasonic C-scan and eddy current imaging systems are based on the same mechanical scanning mechanisms, the two systems can be combined using the same PC platform with a common mechanical manipulation subsystem and integrated data acquisition software. Based on this concept, we have developed an IBM PC-based combined ultrasonic C-scan and eddy current imaging system. The system is modularized and provides capacity for future hardware and software expansions. Advantages associated with the combined system are: (1) eliminated duplication of the computer and mechanical hardware, (2) unified data acquisition, processing and storage software, (3) reduced setup time for repetitious ultrasonic and eddy current scans, and (4) improved system efficiency. The concept can be adapted to many engineering systems by integrating related PC-based instruments into one multipurpose workstation such as dispensing, machining, packaging, sorting, and other industrial applications.
NASA Astrophysics Data System (ADS)
Miyasaka, C.; Tittmann, B. R.; Tutwiler, R.; Tian, Y.; Maeva, E.; Shum, D.
2010-03-01
The present study is to investigate the feasibility of applying in-vivo acoustic microscopy to the analysis of cancerous tissue. The study was implemented with mechanical scanning reflection acoustic microscope (SAM) by the following procedures. First, we ultrasonically visualized thick sections of normal and tumor tissues to determine the lowest transducer frequency required for cellular imaging. We used skin for normal tissue and the tumor was a malignant melanoma. Thin sections of the tissue were also studied with the optical and high-frequency-ultrasonic imaging for pathological evaluation. Secondly, we ultrasonically visualized subsurface cellular details of thin tissue specimens with different modes (i.e., pulse and tone-burst wave modes) to obtain the highest quality ultrasonic images. The objective is to select the best mode for the future design of a future SAM for in-vivo examination. Thirdly, we developed a mathematical modeling technique based on an angular spectrum approach for improving image processing and comparing numerical to experimental results.
2014/2219 Tri-Point Crack Analysis
NASA Technical Reports Server (NTRS)
Horton, Karla Renee
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. The objective of this study was to evaluate the deformation response at the tips of cracks located in the heat affected zone of friction plug welds and to study the fracture behavior of welds with defects in the form of fatigue cracks. The study used existing 2014-T6 to 2219-T87 self-reacting friction stir weld panels with 2219-T87 friction plug welds. Electro-discharge machined (EDM) notches were machined into the heat affected zone of the plug at the plug-to-base metal interface. Samples were then cycled to generate a fatigue crack emanating from the notch. After the fatigue crack reached a pre-defined length, a speckle pattern was applied and the ARAMIS system (a three dimensional imaging correlation system) was used to measure the deformations at the crack tip under a sequence of loads. Testing was conducted at ambient laboratory conditions. Fracture data from the testing was analyzed to evaluate residual strength capability of the panel as a function of flaw size. ARAMIS strain data was evaluated to examine strain and deformation patterns that develop around the crack tip and at the plug/weld interfaces. Four samples were used in this study, with three samples in a post-weld heat treated condition. Three samples contained large diameter plugs (M5) and one sample contained a small diameter plug (M3). Two samples were 4 inches in width and two samples were 8.5 inches in width. All samples failed through the precrack with residual strengths ranging from 37 ksi to 42 ksi.
Ultrasonic imaging of textured alumina
NASA Technical Reports Server (NTRS)
Stang, David B.; Salem, Jonathan A.; Generazio, Edward R.
1989-01-01
Ultrasonic images representing the bulk attenuation and velocity of a set of alumina samples were obtained by a pulse-echo contact scanning technique. The samples were taken from larger bodies that were chemically similar but were processed by extrusion or isostatic processing. The crack growth resistance and fracture toughness of the larger bodies were found to vary with processing method and test orientation. The results presented here demonstrate that differences in texture that contribute to variations in structural performance can be revealed by analytic ultrasonic techniques.
Ultrasonic NDE and mechanical testing of fiber placement composites
NASA Astrophysics Data System (ADS)
Liu, Zhanjie; Fei, Dong; Hsu, David K.; Dayal, Vinay; Hale, Richard D.
2002-05-01
A fiber placed composite, especially with fiber steering, has considerably more complex internal structure than a laminate laid up from unidirectional prepreg tapes. In this work, we performed ultrasonic imaging of ply interfaces of fiber placed composite laminates, with an eye toward developing a tool for evaluating their quality. Mechanical short-beam shear tests were also conducted on both nonsteered and steered specimens to examine their failure behavior and its relationship to the structural defects indicated by ultrasonic imaging.
Reed, Elizabeth; Khoshnood, Kaveh; Blankenship, Kim M.; Fisher, Celia B.
2014-01-01
Female sex workers (FSW) from Andhra Pradesh, India who had participated in HIV research were interviewed to examine participant perspectives on research ethics. Content analysis indicated that aspects of the consent process, staff gender and demeanor, study environment, survey content, time requirements for study participation, and perceived FSW community support for research were key factors influencing whether FSW perceived their confidentiality and privacy had been maintained, and whether they felt the study was conducted respectfully. Findings suggest that partnership with community-based organizations and investigation of participant’s experiences in HIV prevention research can provide critical information to best inform research ethics protocols, a particular priority among research studies with highly stigmatized populations, such as FSW. PMID:24572080
Improved ultrasonic TV images achieved by use of Lamb-wave orientation technique
NASA Technical Reports Server (NTRS)
Berger, H.
1967-01-01
Lamb-wave sample orientation technique minimizes the interference from standing waves in continuous wave ultrasonic television imaging techniques used with thin metallic samples. The sample under investigation is oriented such that the wave incident upon it is not normal, but slightly angled.
Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites
NASA Technical Reports Server (NTRS)
Generazio, Edward R.
1990-01-01
Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.
NASA Astrophysics Data System (ADS)
Mano, Kazune; Tanigawa, Shohei; Hori, Makoto; Yokota, Daiki; Wada, Kenji; Matsunaka, Toshiyuki; Morikawa, Hiroyasu; Horinaka, Hiromichi
2016-07-01
Fatty liver is a disease caused by the excess accumulation of fat in the human liver. The early diagnosis of fatty liver is very important, because fatty liver is the major marker linked to metabolic syndrome. We already proposed the ultrasonic velocity change imaging method to diagnose fatty liver by using the fact that the temperature dependence of ultrasonic velocity is different in water and in fat. For the diagonosis of a fatty liver stage, we attempted a feasibility study of the quantitative assessment of the fat content in the human liver using our ultrasonic velocity change imaging method. Experimental results showed that the fat content in the tissue mimic phantom containing lard was determined by its ultrasonic velocity change in the flat temperature region formed by a circular warming ultrasonic transducer with an acoustic lens having an appropriate focal length. By considering the results of our simulation using a thermal diffusion equation, we determined whether this method could be applied to fatty liver assessment under the condition that the tissue had the thermal relaxation effect caused by blood flow.
Assessing the Risks for Modern Diagnostic Ultrasound Imaging
NASA Astrophysics Data System (ADS)
William, Jr.
1998-05-01
Some 35 years after Paul-Jacques and Pierre Curie discovered piezoelectricity, ultrasonic imaging was developed by Paul Langevin. During this work, ultrasonic energy was observed to have a detrimental biological effect. These observations were confirmed a decade later by R. W. Wood and A. L. Loomis. It was not until the early 1950s that ultrasonic exposure conditions were controlled and specified so that studies could focus on the mechanisms by which ultrasound influenced biological materials. In the late 1940s, pioneering work was initiated to image the human body by ultrasonic techniques. These engineers and physicians were aware of the deleterious ultrasound effects at sufficiently high levels; this endeavored them to keep the exposure levels reasonably low. Over the past three decades, diagnostic ultrasound has become a sophisticated technology. Yet, our understanding of the potential risks has not changed appreciably. It is very encouraging that human injury has never been attributed to clinical practice of diagnostic ultrasound.
Decker, Michele R; McCauley, Heather L; Phuengsamran, Dusita; Janyam, Surang; Seage, George R; Silverman, Jay G
2010-06-01
Commercial sex work is a primary context for heterosexual HIV/AIDS transmission. Violence victimisation is considered to compromise women's ability to protect against HIV and other sexually transmitted infections (STI); little research has investigated violence as it relates to sexual risk and STI among female sex workers (FSW). This study sought to compare sexual risk and STI symptoms among FSW based on recent violence exposure. Data from 815 FSW in Thailand were used to assess the prevalence of physical or sexual violence within the context of sex work, and associations of victimisation with sexual risk and STI symptoms. Approximately one in seven FSW (14.6%) had experienced violence in the week before the survey. Compared with their unexposed counterparts, FSW exposed to violence demonstrated a greater risk of condom failure (19.6% vs 12.3%, ARR 1.92, 95% CI 1.24 to 2.95) and client condom refusal (85.7% vs 69.0%, ARR 1.24, 95% CI 1.14 to 1.35). In analyses adjusted for sexual risk, violence related to STI symptoms collectively (ARR 1.11, 95% CI 1.02 to 1.21) and genital lesions as an individual STI symptom (ARR 1.78, 95% CI 1.20 to 2.66). Physical and sexual violence against FSW in Thailand appears to be common, with women experiencing such violence demonstrating diminished capacity for STI/HIV harm reduction and greater prevalence of STI symptoms. Efforts to reduce violence towards this vulnerable population must be prioritised, as a means of protecting the health and wellbeing of FSW, and as a key component of STI/HIV prevention and control.
Friction-Stir Welding - Heavy Inclusions in Bi-metallic welds of Al 2219/2195
NASA Technical Reports Server (NTRS)
Rietz, Ward W., Jr.
2008-01-01
Heavy Inclusions (HI) were detected for the first time by radiographic examination in aluminum alloy 2219forging/2195plate (advancing/retreating side) Friction Sir Welds (FSW) for the Space Shuttle External Tank (ET) Program. Radiographic HI indications appear as either small (approx.0.005"-0.025") individual particles or clusters of small particles. Initial work was performed to verify that the HI was not foreign material or caused by FSW pin tool debris. That and subsequent elemental analysis determined that the HI were large agglomerations of Al2Cu (theta phase), which is the strengthening precipitate in Al2219. A literature search on that subject determined that the agglomeration of phase has also been found in Al2219 bead on plate FSW [Ref. 1]. Since this was detected in ET space flight hardware, an investigative study of the effect of agglomerated theta phase particles in FSW Al2219f/2195p was performed. Numerous panels of various lengths were welded per ET weld procedures and radiographically inspected to determine if any HI was detected. Areas that had HI were sampled for room temperature and cyclic cryogenic (-423F) tensile testing and determined no significant adverse affect on mechanical properties when compared to test specimens without HI and historical data. Fracture surface examination using the Scanning Electron Microscope (SEM) revealed smaller phase agglomerations undetectable by radiographic inspection dispersed throughout the Al2219f/2195p FSW. This indicates that phase agglomeration is inherent to the Al2219f/2195p FSW process and only rarely creates agglomerations large enough to be detected by radiography. HI has not been observed in FSW of plate to plate material for either Al2219 or AL2195.
NASA Astrophysics Data System (ADS)
Daneji, A.; Ali, M.; Pervaiz, S.
2018-04-01
Friction stir welding (FSW) is a form of solid state welding process for joining metals, alloys, and selective composites. Over the years, FSW development has provided an improved way of producing welding joints, and consequently got accepted in numerous industries such as aerospace, automotive, rail and marine etc. In FSW, the base metal properties control the material’s plastic flow under the influence of a rotating tool whereas, the process and tool parameters play a vital role in the quality of weld. In the current investigation, an array of square butt joints of 6061 Aluminum alloy was to be welded under varying FSW process and tool geometry related parameters, after which the resulting weld was evaluated for the corresponding mechanical properties and welding defects. The study incorporates FSW process and tool parameters such as welding speed, pin height and pin thread pitch as input parameters. However, the weld quality related defects and mechanical properties were treated as output parameters. The experimentation paves way to investigate the correlation between the inputs and the outputs. The correlation between inputs and outputs were used as tool to predict the optimized FSW process and tool parameters for a desired weld output of the base metals under investigation. The study also provides reflection on the effect of said parameters on a welding defect such as wormhole.
21 CFR 884.2225 - Obstetric-gynecologic ultrasonic imager.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Obstetric-gynecologic ultrasonic imager. 884.2225 Section 884.2225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... generic type of device may include the following: signal analysis and display equipment, electronic...
21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed echo imaging system. 892.1560 Section 892.1560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... receiver. This generic type of device may include signal analysis and display equipment, patient and...
21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed echo imaging system. 892.1560 Section 892.1560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... receiver. This generic type of device may include signal analysis and display equipment, patient and...
21 CFR 884.2225 - Obstetric-gynecologic ultrasonic imager.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Obstetric-gynecologic ultrasonic imager. 884.2225 Section 884.2225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... generic type of device may include the following: signal analysis and display equipment, electronic...
21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed echo imaging system. 892.1560 Section 892.1560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... receiver. This generic type of device may include signal analysis and display equipment, patient and...
21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... include signal analysis and display equipment, patient and equipment supports, component parts, and...
21 CFR 884.2225 - Obstetric-gynecologic ultrasonic imager.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Obstetric-gynecologic ultrasonic imager. 884.2225 Section 884.2225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... generic type of device may include the following: signal analysis and display equipment, electronic...
21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... include signal analysis and display equipment, patient and equipment supports, component parts, and...
Fatigue Strength Estimation Based on Local Mechanical Properties for Aluminum Alloy FSW Joints
Sillapasa, Kittima; Mutoh, Yoshiharu; Miyashita, Yukio; Seo, Nobushiro
2017-01-01
Overall fatigue strengths and hardness distributions of the aluminum alloy similar and dissimilar friction stir welding (FSW) joints were determined. The local fatigue strengths as well as local tensile strengths were also obtained by using small round bar specimens extracted from specific locations, such as the stir zone, heat affected zone, and base metal. It was found from the results that fatigue fracture of the FSW joint plate specimen occurred at the location of the lowest local fatigue strength as well as the lowest hardness, regardless of microstructural evolution. To estimate the fatigue strengths of aluminum alloy FSW joints from the hardness measurements, the relationship between fatigue strength and hardness for aluminum alloys was investigated based on the present experimental results and the available wide range of data from the references. It was found as: σa (R = −1) = 1.68 HV (σa is in MPa and HV has no unit). It was also confirmed that the estimated fatigue strengths were in good agreement with the experimental results for aluminum alloy FSW joints. PMID:28772543
Fatigue Strength Estimation Based on Local Mechanical Properties for Aluminum Alloy FSW Joints.
Sillapasa, Kittima; Mutoh, Yoshiharu; Miyashita, Yukio; Seo, Nobushiro
2017-02-15
Overall fatigue strengths and hardness distributions of the aluminum alloy similar and dissimilar friction stir welding (FSW) joints were determined. The local fatigue strengths as well as local tensile strengths were also obtained by using small round bar specimens extracted from specific locations, such as the stir zone, heat affected zone, and base metal. It was found from the results that fatigue fracture of the FSW joint plate specimen occurred at the location of the lowest local fatigue strength as well as the lowest hardness, regardless of microstructural evolution. To estimate the fatigue strengths of aluminum alloy FSW joints from the hardness measurements, the relationship between fatigue strength and hardness for aluminum alloys was investigated based on the present experimental results and the available wide range of data from the references. It was found as: σ a ( R = -1) = 1.68 HV ( σ a is in MPa and HV has no unit). It was also confirmed that the estimated fatigue strengths were in good agreement with the experimental results for aluminum alloy FSW joints.
NASA Technical Reports Server (NTRS)
Schneider, Judy; Nunes, Arthur C., Jr.; Brendel, Michael S.
2010-01-01
Although friction stir welding (FSW) was patented in 1991, process development has been based upon trial and error and the literature still exhibits little understanding of the mechanisms determining weld structure and properties. New concepts emerging from a better understanding of these mechanisms enhance the ability of FSW engineers to think about the FSW process in new ways, inevitably leading to advances in the technology. A kinematic approach in which the FSW flow process is decomposed into several simple flow components has been found to explain the basic structural features of FSW welds and to relate them to tool geometry and process parameters. Using this modelling approach, this study reports on a correlation between the features of the weld nugget, process parameters, weld tool geometry, and weld strength. This correlation presents a way to select process parameters for a given tool geometry so as to optimize weld strength. It also provides clues that may ultimately explain why the weld strength varies within the sample population.
Ojeda, Victoria D.; Burgos, José Luis; Hiller, Sarah P.; Lozada, Remedios; Rangel, Gudelia; Vera, Alicia; Artamonova, Irina; Rodriguez, Carlos Magis
2013-01-01
Background Circular migration and injection drug use increase the risk of HIV transmission in sending communities. We describe female sex workers who are injection drug users’ (FSW-IDUs) circular migration and drug use behaviors. Methods Between 2008-2010, 258 migrant FSW-IDUs residing in Tijuana and Ciudad Juarez, Mexico responded to questionnaires. Results 24% of FSW-IDUs were circular migrants. HIV prevalence was 3.3% in circular migrants and 6.1% in non-circular migrants; 50% of circular and 82% of non-circular migrants were unaware of their HIV infection. Among circular migrants, 44% (n=27) consumed illicit drugs in their birthplace; 70% of these (n=20) injected drugs and one-half of injectors shared injection equipment in their birthplace. Women reporting active social relationships were significantly more likely to return home. Discussion Circular migrant FSW-IDUs exhibit multiple HIV risks and opportunities for bridging populations. Regular HIV testing and treatment and access to substance use services is critical for FSW-IDUs and their sexual/drug-using contacts. PMID:21833727
Computer Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding
NASA Technical Reports Server (NTRS)
Schneider, Judy; Beshears, Ronald; Nunes, Arthur C., Jr.
2004-01-01
In friction stir welding, a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. This solid-state technique has been successfully used in the joining of materials that are difficult to fusion weld such as aluminum alloys. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and thus tracks the aluminum deformation flow paths in a unique 3-dimensional manner. CT scanning is a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.
NASA Astrophysics Data System (ADS)
Chu, Guannan; Sun, Lei; Lin, Caiyuan; Lin, Yanli
2017-11-01
To improve the formability of the aluminum alloy welds and overcome the size limitation of the bulk post weld heat treatment (BPWHT) on large size friction stir welded joints, a local post weld heat treatment method (LPWHT) was proposed. In this method, the resistance heating as the moving heat source is adopted to only heat the weld seam. The temperature field of LPWHT and its influence on the mechanical properties and formability of FSW 2219-O Al alloy joints was investigated. The evaluation of the tensile properties of FSW samples was also examined by mapping the global and local strain distribution using the digital image correlation methodology. The results indicated that the formability was improved greatly after LPWHT, while the hardness distribution of the FSW joint was homogenized. The maximum elongation can reach 1.4 times that of as-welded joints with increase the strength and the strain of the nugget zone increased from 3 to 8% when annealing at 300 °C. The heterogeneity on the tensile deformation of the as-welded joints was improved by the nugget zone showing large local strain value and the reason was given according to the dimple fracture characteristics at different annealing temperatures. The tensile strength and elongation of LPWHT can reach 93.3 and 96.1% of the BPWHT, respectively. Thus, the LPWHT can be advantageous compared to the BPWHT for large size welds.
Laser-Generated Ultrasonic Source for a Real-Time Dry-Contact Imaging System
NASA Astrophysics Data System (ADS)
Petculescu, G.; Zhou, Y.; Komsky, I.; Krishnaswamy, S.
2006-03-01
A laser-generated ultrasonic source, to be used with a real-time imaging device, was developed. The ultrasound is generated in the thermoelastic regime, in a composite layer composed of absorbing particles (carbon) and silicone rubber. The composite layer plays three roles: of absorption, constriction and dry-coupling. The central frequency of the generated pulse was controlled by varying the absorption depth of the generation layer. The maximum peak frequency obtained was 4MHz. When additional constriction was provided to the composite layer, the amplitude of the generated signal increased further, due to the large thermal expansion coefficient of the silicone. Images using the laser-generated ultrasonic source were taken.
NASA Technical Reports Server (NTRS)
Lovelace, Jeffrey J.; Cios, Kryzsztof J.; Roth, Don J.; cAO, wEI n.
2001-01-01
Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact measurement data obtained at NASA Glenn Research Center's Ultrasonic Nondestructive Evaluation measurement facility. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary waveforms in the time and frequency domains along with the calculation of several frequency-dependent properties including phase velocity and attenuation coefficient and several frequency-independent properties, like the cross correlation velocity. The system allows image generation on all the frequency-dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency-independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of indepth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on an SQL data base. It is ideal for the classification of material properties or the location of microstructure variations in materials. Along with the ultrasonic contact measurement software that it is partnered with, this system is technology ready and can be transferred to users worldwide.
Ultrasonic Waves in Water Visualized With Schlieren Imaging
NASA Technical Reports Server (NTRS)
Juergens, Jeffrey R.
2000-01-01
The Acoustic Liquid Manipulation project at the NASA Glenn Research Center at Lewis Field is working with high-intensity ultrasound waves to produce acoustic radiation pressure and acoustic streaming. These effects can be used to propel liquid flows to manipulate floating objects and liquid surfaces. Interest in acoustic liquid manipulation has been shown in acoustically enhanced circuit board electroplating, microelectromechanical systems (MEMS), and microgravity space experiments. The current areas of work on this project include phased-array ultrasonic beam steering, acoustic intensity measurements, and schlieren imaging of the ultrasonic waves.
Xia, Jun; Huang, Chao; Maslov, Konstantin; Anastasio, Mark A; Wang, Lihong V
2013-08-15
Photoacoustic computed tomography (PACT) is a hybrid technique that combines optical excitation and ultrasonic detection to provide high-resolution images in deep tissues. In the image reconstruction, a constant speed of sound (SOS) is normally assumed. This assumption, however, is often not strictly satisfied in deep tissue imaging, due to acoustic heterogeneities within the object and between the object and the coupling medium. If these heterogeneities are not accounted for, they will cause distortions and artifacts in the reconstructed images. In this Letter, we incorporated ultrasonic computed tomography (USCT), which measures the SOS distribution within the object, into our full-ring array PACT system. Without the need for ultrasonic transmitting electronics, USCT was performed using the same laser beam as for PACT measurement. By scanning the laser beam on the array surface, we can sequentially fire different elements. As a first demonstration of the system, we studied the effect of acoustic heterogeneities on photoacoustic vascular imaging. We verified that constant SOS is a reasonable approximation when the SOS variation is small. When the variation is large, distortion will be observed in the periphery of the object, especially in the tangential direction.
Hot topics in biomedical ultrasound: ultrasound therapy and its integration with ultrasonic imaging
NASA Astrophysics Data System (ADS)
Everbach, E. Carr
2005-09-01
Since the development of biomedical ultrasound imaging from sonar after WWII, there has been a clear divide between ultrasonic imaging and ultrasound therapy. While imaging techniques are designed to cause as little change as possible in the tissues through which ultrasound propagates, ultrasound therapy typically relies upon heating or acoustic cavitation to produce a desirable therapeutic effect. Concerns over the increasingly high acoustic outputs of diagnostic ultrasound scanners prompted the adoption of the Mechanical Index (MI) and Thermal Index (TI) in the early 1990s. Therapeutic applications of ultrasound, meanwhile, have evolved from deep tissue heating in sports medicine to include targeted drug delivery, tumor and plaque ablation, cauterization via high intensity focused ultrasound (HIFU), and accelerated dissolution of blood clots. The integration of ultrasonic imaging and therapy in one device is just beginning, but the promise of improved patient outcomes is balanced by regulatory and practical impediments.
MIMO nonlinear ultrasonic tomography by propagation and backpropagation method.
Dong, Chengdong; Jin, Yuanwei
2013-03-01
This paper develops a fast ultrasonic tomographic imaging method in a multiple-input multiple-output (MIMO) configuration using the propagation and backpropagation (PBP) method. By this method, ultrasonic excitation signals from multiple sources are transmitted simultaneously to probe the objects immersed in the medium. The scattering signals are recorded by multiple receivers. Utilizing the nonlinear ultrasonic wave propagation equation and the received time domain scattered signals, the objects are to be reconstructed iteratively in three steps. First, the propagation step calculates the predicted acoustic potential data at the receivers using an initial guess. Second, the difference signal between the predicted value and the measured data is calculated. Third, the backpropagation step computes updated acoustical potential data by backpropagating the difference signal to the same medium computationally. Unlike the conventional PBP method for tomographic imaging where each source takes turns to excite the acoustical field until all the sources are used, the developed MIMO-PBP method achieves faster image reconstruction by utilizing multiple source simultaneous excitation. Furthermore, we develop an orthogonal waveform signaling method using a waveform delay scheme to reduce the impact of speckle patterns in the reconstructed images. By numerical experiments we demonstrate that the proposed MIMO-PBP tomographic imaging method results in faster convergence and achieves superior imaging quality.
Statistical ultrasonics: the influence of Robert F. Wagner
NASA Astrophysics Data System (ADS)
Insana, Michael F.
2009-02-01
An important ongoing question for higher education is how to successfully mentor the next generation of scientists and engineers. It has been my privilege to have been mentored by one of the best, Dr Robert F. Wagner and his colleagues at the CDRH/FDA during the mid 1980s. Bob introduced many of us in medical ultrasonics to statistical imaging techniques. These ideas continue to broadly influence studies on adaptive aperture management (beamforming, speckle suppression, compounding), tissue characterization (texture features, Rayleigh/Rician statistics, scatterer size and number density estimators), and fundamental questions about how limitations of the human eye-brain system for extracting information from textured images can motivate image processing. He adapted the classical techniques of signal detection theory to coherent imaging systems that, for the first time in ultrasonics, related common engineering metrics for image quality to task-based clinical performance. This talk summarizes my wonderfully-exciting three years with Bob as I watched him explore topics in statistical image analysis that formed a rational basis for many of the signal processing techniques used in commercial systems today. It is a story of an exciting time in medical ultrasonics, and of how a sparkling personality guided and motivated the development of junior scientists who flocked around him in admiration and amazement.
Three-Dimensional Ultrasonic Imaging Of The Cornea
NASA Technical Reports Server (NTRS)
Heyser, Rrichar C.; Rooney, James A.
1988-01-01
Proposed technique generates pictures of curved surfaces. Object ultrasonically scanned in raster pattern generated by scanning transmitter/receiver. Receiver turned on at frequent intervals to measure depth variations of scanned object. Used for medical diagnoses by giving images of small curved objects as cornea. Adaptable to other types of reflection measurementsystems such as sonar and radar.
DOT National Transportation Integrated Search
2013-04-01
This report covers the work performed under the FRA High-Speed BAA 20102011 program to demonstrate the technology of ultrasonic tomography for 3-D imaging of internal rail flaws. There is a need to develop new technologies that are able to quantif...
2006-02-01
Pesavento , A., and A. Lorenz., Real time strain imaging and in vivo applications in prostate cancer. In IEEE Ultrasonics Symposium, l2, pp.1251-1253...hardening of tissue to increase contrast in elasticity imaging. In IEEE Ultrasonics Symposium. 2: pp. 1833-1836, 2000. [6] Pesavento A, L.A., Ermert H
Halford, Andrew; Ohl, Claus-Dieter; Azarpazhooh, Amir; Basrani, Bettina; Friedman, Shimon; Kishen, Anil
2012-11-01
Irrigation dynamics and antibacterial activity determine the efficacy of root canal disinfection. Sonic or ultrasonic agitation of irrigants is expected to improve irrigation dynamics. This study examined the effects of microbubble emulsion (ME) combined with sonic or ultrasonic agitation on irrigation dynamics and reduction of biofilm bacteria within root canal models. Two experiments were conducted. First, high-speed imaging was used to characterize the bubble dynamics generated in ME by sonic or ultrasonic agitation within canals of polymer tooth models. Second, 5.25% NaOCl irrigation or ME was sonically or ultrasonically agitated in canals of extracted teeth with 7-day-grown Enterococcus faecalis biofilms. Dentinal shavings from canal walls were sampled at 1 mm and 3 mm from the apical terminus, and colony-forming units (CFUs) were enumerated. Mean log CFU/mL values were analyzed with analysis of variance and post hoc tests. High-speed imaging demonstrated strongly oscillating and vaporizing bubbles generated within ME during ultrasonic but not sonic agitation. Compared with CFU counts in controls, NaOCl-sonic and NaOCl-ultrasonic yielded significantly lower counts (P < .05) at both measurement levels. ME-sonic yielded significantly lower counts (P = .002) at 3 mm, whereas ME-ultrasonic yielded highly significantly lower counts (P = .000) at both measurement levels. At 3 mm, ME-ultrasonic yielded significantly lower CFU counts (P = .000) than ME-sonic, NaOCl-sonic, and NaOCl-ultrasonic. Enhanced bubble dynamics and reduced E. faecalis biofilm bacteria beyond the level achieved by sonic or ultrasonic agitation of NaOCl suggested a synergistic effect of ME combined with ultrasonic agitation. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Modeling of AA5083 Material-Microstructure Evolution During Butt Friction-Stir Welding
NASA Astrophysics Data System (ADS)
Grujicic, M.; Arakere, G.; Yalavarthy, H. V.; He, T.; Yen, C.-F.; Cheeseman, B. A.
2010-07-01
A concise yet a fairly comprehensive overview of the friction stir welding (FSW) process is provided. This is followed by a computational investigation in which FSW behavior of a prototypical solution-strengthened and strain-hardened aluminum alloy, AA5083-H131, is modeled using a fully coupled thermo-mechanical finite-element procedure developed in our prior study. Particular attention is given to proper modeling of the welding work-piece material behavior during the FSW process. Specifically, competition and interactions between plastic-deformation and dynamic-recrystallization processes are considered to properly account for the material-microstructure evolution in the weld nugget zone. The results showed that with proper modeling of the material behavior under high-temperature/severe-plastic-deformation conditions, significantly improved agreement can be attained between the computed and measured post-FSW residual-stress and material-strength distribution results.
Prolegomena to the Study of Friction Stir Welding
NASA Technical Reports Server (NTRS)
Nunes, Arthur C., Jr.
2010-01-01
The literature contains many approaches toward modeling of the friction stir welding (FSW) process with varying treatments of the weld metal properties. It is worthwhile to consider certain fundamental features of the process before attempting to interpret FSW phenomena: Because of the unique character of metal deformation (as opposed to, say, viscous deformation) a velocity "discontinuity" or shear surface occurs in FSW and determines much of the character of the welding mechanism. A shear surface may not always produce a sound bond. Balancing mechanical power input against conduction and convection heat losses yields a relation, a "temperature index", between spindle speed and travel speed to maintain constant weld temperature. But many process features are only weakly dependent upon temperature. Thus, unlike modeling of metal forming processes, it may be that modeling the FSW process independently of the material conditions has some merit.
Friction Stir Welding and NASA
NASA Technical Reports Server (NTRS)
Horton, K Renee
2016-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks and other areas used on the Space Launch System (SLS) NASA's SLS is an advanced, heavy-lift launch vehicle which will provide an entirely new capability for science and human exploration beyond Earth's orbit. The SLS will give the nation a safe, affordable and sustainable means of reaching beyond our current limits and open new doors of discovery from the unique vantage point of space This talk will elaborate on the SR-FSW process and it's usage on the current Space Launch System Program at NASA.
Cassini's Test Methodology for Flight Software Verification and Operations
NASA Technical Reports Server (NTRS)
Wang, Eric; Brown, Jay
2007-01-01
The Cassini spacecraft was launched on 15 October 1997 on a Titan IV-B launch vehicle. The spacecraft is comprised of various subsystems, including the Attitude and Articulation Control Subsystem (AACS). The AACS Flight Software (FSW) and its development has been an ongoing effort, from the design, development and finally operations. As planned, major modifications to certain FSW functions were designed, tested, verified and uploaded during the cruise phase of the mission. Each flight software upload involved extensive verification testing. A standardized FSW testing methodology was used to verify the integrity of the flight software. This paper summarizes the flight software testing methodology used for verifying FSW from pre-launch through the prime mission, with an emphasis on flight experience testing during the first 2.5 years of the prime mission (July 2004 through January 2007).
NASA Astrophysics Data System (ADS)
Atif Wahid, Mohd; Siddiquee, Arshad Noor; Khan, Zahid A.; Sharma, Nidhi
2018-04-01
The aim of the present study is to investigate the effect of cooling media on the temperature distribution, microstructure and mechanical properties of the joint produced during Underwater Friction Stir Welding (UFSW) in normal water, cold water (water with crushed ice (CFSW)) and air (FSW), for aluminum alloy (AA) 6082-T6. The results showed that peak temperature during UFSW and CFSW were significantly lower than the FSW. The temperature at the advancing side (AS) of the joint was higher than the retreating side (RS). Substantial reduction in TMAZ/HAZ width was observed during UFSW and CFSW as compared to FSW. Al-Mn-Fe-Si intermetallic phases were seen in all the joints along with the BM. The main strengthening precipitates found in UFSW and CFSW was β″ (Mg5Si6) which changed to β (Mg2Si) precipitates during FSW due to increased temperature. The tensile strength of the joints was best during UFSW followed by FSW and CFSW. The controlled temperature distribution resulted in improved tensile strength whereas both undercooling and overcooling resulted in decreased tensile strength, however, increased cooling rate does not improve the elongation. A typical ‘W’ shape hardness profile was observed in all the joints irrespective of the cooling media used. Maximum hardness was obtained in the UFSW joint due to refined grain structure, high-density dislocations and presence of β″ phases.
Hladik, Wolfgang; Baughman, Andrew L; Serwadda, David; Tappero, Jordan W; Kwezi, Rachel; Nakato, Namakula D; Barker, Joseph
2017-06-10
Sex workers in Uganda are at significant risk for HIV infection. We characterized the HIV epidemic among Kampala female sex workers (FSW). We used respondent-driven sampling to sample FSW aged 15+ years who reported having sold sex to men in the preceding 30 days; collected data through audio-computer assisted self-interviews, and tested blood, vaginal and rectal swabs for HIV, syphilis, neisseria gonorrhea, chlamydia trachomatis, and trichomonas vaginalis. A total of 942 FSW were enrolled from June 2008 through April 2009. The overall estimated HIV prevalence was 33% (95% confidence intervals [CI] 30%-37%) and among FSW 25 years or older was 44%. HIV infection is associated with low levels of schooling, having no other work, never having tested for HIV, self-reported genital ulcers or sores, and testing positive for neisseria gonorrhea or any sexually transmitted infections (STI). Two thirds (65%) of commercial sex acts reportedly were protected by condoms; one in five (19%) FSW reported having had anal sex. Gender-based violence was frequent; 34% reported having been raped and 24% reported having been beaten by clients in the preceding 30 days. One in three FSW in Kampala is HIV-infected, suggesting a severe HIV epidemic in this population. Intensified interventions are warranted to increase condom use, HIV testing, STI screening, as well as antiretroviral treatment and pre-exposure prophylaxis along with measures to overcome gender-based violence.
CERES Monthly Gridded Single Satellite Fluxes and Clouds (FSW) in HDF (CER_FSW_TRMM-PFM-VIRS_Beta1)
NASA Technical Reports Server (NTRS)
Wielicki, Bruce A. (Principal Investigator); Barkstrom, Bruce R. (Principal Investigator)
The Monthly Gridded Radiative Fluxes and Clouds (FSW) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The FSW is also produced for combinations of scanner instruments. All instantaneous fluxes from the CERES CRS product for a month are sorted by 1-degree spatial regions and by the Universal Time (UT) hour of observation. The mean of the instantaneous fluxes for a given region-hour bin is determined and recorded on the FSW along with other flux statistics and scene information. The mean adjusted fluxes at the four atmospheric levels defined by CRS are also included for both clear-sky and total-sky scenes. In addition, four cloud height categories are defined by dividing the atmosphere into four intervals with boundaries at the surface, 700-, 500-, 300-hPa, and the Top-of-the-Atmosphere (TOA). The cloud layers from CRS are put into one of the cloud height categories and averaged over the region. The cloud properties are also column averaged and included on the FSW. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2000-03-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=1 degree; Horizontal_Resolution_Range=100 km - < 250 km or approximately 1 degree - < 2.5 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].
NASA Technical Reports Server (NTRS)
Wielicki, Bruce A. (Principal Investigator); Barkstrom, Bruce R. (Principal Investigator)
The Monthly Gridded Radiative Fluxes and Clouds (FSW) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The FSW is also produced for combinations of scanner instruments. All instantaneous fluxes from the CERES CRS product for a month are sorted by 1-degree spatial regions and by the Universal Time (UT) hour of observation. The mean of the instantaneous fluxes for a given region-hour bin is determined and recorded on the FSW along with other flux statistics and scene information. The mean adjusted fluxes at the four atmospheric levels defined by CRS are also included for both clear-sky and total-sky scenes. In addition, four cloud height categories are defined by dividing the atmosphere into four intervals with boundaries at the surface, 700-, 500-, 300-hPa, and the Top-of-the-Atmosphere (TOA). The cloud layers from CRS are put into one of the cloud height categories and averaged over the region. The cloud properties are also column averaged and included on the FSW. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=1 degree; Horizontal_Resolution_Range=100 km - < 250 km or approximately 1 degree - < 2.5 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].
NASA Technical Reports Server (NTRS)
Wielicki, Bruce A. (Principal Investigator); Barkstrom, Bruce R. (Principal Investigator)
The Monthly Gridded Radiative Fluxes and Clouds (FSW) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The FSW is also produced for combinations of scanner instruments. All instantaneous fluxes from the CERES CRS product for a month are sorted by 1-degree spatial regions and by the Universal Time (UT) hour of observation. The mean of the instantaneous fluxes for a given region-hour bin is determined and recorded on the FSW along with other flux statistics and scene information. The mean adjusted fluxes at the four atmospheric levels defined by CRS are also included for both clear-sky and total-sky scenes. In addition, four cloud height categories are defined by dividing the atmosphere into four intervals with boundaries at the surface, 700-, 500-, 300-hPa, and the Top-of-the-Atmosphere (TOA). The cloud layers from CRS are put into one of the cloud height categories and averaged over the region. The cloud properties are also column averaged and included on the FSW. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2001-10-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=1 degree; Horizontal_Resolution_Range=100 km - < 250 km or approximately 1 degree - < 2.5 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Lianjie
Methods for enhancing ultrasonic reflection imaging are taught utilizing a split-step Fourier propagator in which the reconstruction is based on recursive inward continuation of ultrasonic wavefields in the frequency-space and frequency-wave number domains. The inward continuation within each extrapolation interval consists of two steps. In the first step, a phase-shift term is applied to the data in the frequency-wave number domain for propagation in a reference medium. The second step consists of applying another phase-shift term to data in the frequency-space domain to approximately compensate for ultrasonic scattering effects of heterogeneities within the tissue being imaged (e.g., breast tissue). Resultsmore » from various data input to the method indicate significant improvements are provided in both image quality and resolution.« less
Mohapatra, S; Sarkar, B; Samantaray, D P; Daware, A; Maity, S; Pattnaik, S; Bhattacharjee, S
2017-12-01
Currently, one of the major problem affecting the world is solid waste management, predominantly petroleum-based plastic and fish solid waste (FSW). However, it is very difficult to reduce the consumption of plastic as well as fish products, but it is promising to convert FSW to biopolymer to reduce eco-pollution. On account of that, the bioconversion of FSW extract to polyhydroxybutyrate (PHB) was undertaken by using Bacillus subtilis (KP172548). Under optimized conditions, 1.62 g/L of PHB has been produced by the bacterium. The purified compound was further characterized by advanced analytical technologies to elucidate its chemical structure. Results indicated that the biopolymer was found to be PHB, the most common homopolymer of polyhydroxyalkanoates (PHAs). This is the first report demonstrating the efficacy of B. subtilis to utilize FSW extract to produce biopolymer. The biocompatibility of the PHB against murine macrophage cell line RAW264.7 demonstrated that, it was comparatively less toxic, favourable for surface attachment and proliferation in comparison with poly-lactic acid (PLA) and commercially available PHB. Thus, further exploration is highly indispensable to use FSW extract as a substrate for production of PHB at pilot scale.
NASA Astrophysics Data System (ADS)
Thomä, M.; Wagner, G.; Straß, B.; Wolter, B.; Benfer, S.; Fürbeth, W.
2017-03-01
The process of friction stir welding (FSW) is an innovative joining technique, which proved its potential in joining dissimilar metals that are poorly fusion weldable. This ability opens a wide range for applications in industrial fields, where weight reduction by partial substitution of conventional materials through lightweight materials is a current central aim. As a consequence of this, the realization of aluminum / steel-joints is of great interest. For this material compound, several friction stir welds were carried out by different researchers for varying Al/steel-joints, whereas the definition of optimal process parameters as well as the increase of mechanical properties was in the focus of the studies. To achieve further improved properties for this dissimilar joint a newly developed hybrid process named “ultrasound enhanced friction stir welding (USE-FSW)” was applied. In this paper the resulting properties of Al/steel-joints using FSW and USE-FSW will be presented and compared. Furthermore, first results by using the nondestructive testing method “computer laminography” to analyze the developed joining area will be shown supplemented by detailed light-microscopic investigations, scanning electron microscopic analysis, and EDX.
Vegas-Sanchez-Ferrero, G; Aja-Fernandez, S; Martin-Fernandez, M; Frangi, A F; Palencia, C
2010-01-01
A novel anisotropic diffusion filter is proposed in this work with application to cardiac ultrasonic images. It includes probabilistic models which describe the probability density function (PDF) of tissues and adapts the diffusion tensor to the image iteratively. For this purpose, a preliminary study is performed in order to select the probability models that best fit the stastitical behavior of each tissue class in cardiac ultrasonic images. Then, the parameters of the diffusion tensor are defined taking into account the statistical properties of the image at each voxel. When the structure tensor of the probability of belonging to each tissue is included in the diffusion tensor definition, a better boundaries estimates can be obtained instead of calculating directly the boundaries from the image. This is the main contribution of this work. Additionally, the proposed method follows the statistical properties of the image in each iteration. This is considered as a second contribution since state-of-the-art methods suppose that noise or statistical properties of the image do not change during the filter process.
2012-02-01
method to image fatigue cracks without requiring damage-free baseline measurements. Load-differential imaging maps changes in ultrasonic signals...caused by a small increase in applied load to an image, which enables detecting and locating fatigue cracks that open under load and thus distinguishing...them from other load-dependent effects. This method was successfully demonstrated in the laboratory during fatigue tests on a variety of aluminum
System and method for ultrasonic tomography
Haddad, Waleed Sami
2002-01-01
A system and method for doing both transmission mode and reflection mode three-dimensional ultrasonic imagining. The multimode imaging capability may be used to provide enhanced detectability of cancer tumors within human breast, however, similar imaging systems are applicable to a number of other medical problems as well as a variety of non-medical problems in non-destructive evaluation (NDE).
Zhang, Wenlu; Chen, Fengyi; Ma, Wenwen; Rong, Qiangzhou; Qiao, Xueguang; Wang, Ruohui
2018-04-16
A fringe visibility enhanced fiber-optic Fabry-Perot interferometer based ultrasonic sensor is proposed and experimentally demonstrated for seismic physical model imaging. The sensor consists of a graded index multimode fiber collimator and a PTFE (polytetrafluoroethylene) diaphragm to form a Fabry-Perot interferometer. Owing to the increase of the sensor's spectral sideband slope and the smaller Young's modulus of the PTFE diaphragm, a high response to both continuous and pulsed ultrasound with a high SNR of 42.92 dB in 300 kHz is achieved when the spectral sideband filter technique is used to interrogate the sensor. The ultrasonic reconstructed images can clearly differentiate the shape of models with a high resolution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Templeman, Yael
One of the major drawbacks of Mg alloys is poor weldability, caused by porosity formation during conventional fusion welding processes. Friction Stir Welding (FSW) is promising technique in this context since it is a solid state technique. Contradicting results were published in the literature regarding the FSWed Mg alloys joint's properties. Current research was performed in order to investigate the microstructure and corrosion properties of FSWed Mg alloys, studying representatives of two commercial families: wrought AZ31-H24 and die cast AM50. It was found that in both alloys recrystallization occurred during the FSW. In AM50 the mechanism of the recrystallization wasmore » continuous, manifested by dislocation rearrangement into sub grain boundaries. In AZ31 discontinuous recrystallization had occurred through grain boundaries migration - twins rotated with respect to the matrix, turning into low angle grain boundaries. Corrosion resistance has improved during the FSW in both alloys to different extents. In the AM50 alloy, the nugget exhibited significantly higher surface potential than the base metal mainly due to the higher Al concentration in the matrix of the nugget, resulting from the dissolution of Al-enrichment and β-Mg{sub 17}Al{sub 12} phase. In the AZ31 alloy, no change in Al concentration had occurred, and the surface potential measured in the nugget was only slightly higher than in the base metal. These results underline the appropriateness of the FSW for Mg alloys since during the conventional welding deterioration of the corrosion resistance occurs. - Highlights: • Following FSW, AZ31-H24 experienced discontinuous recrystallization. • In AZ31 grain boundaries migration occurred, thus twins rotated. • In die cast AM50 continuous recrystallization occurred during the FSW. • In AM50 - dislocations rearranged into sub grain boundaries. • Corrosion resistance has improved during the FSW in both alloys to different extent.« less
Subramanian, Thilakavathi; Gupte, Mohan D; Paranjape, Ramesh S; Brahmam, Ginnela N V; Ramakrishnan, Lakshmi; Adhikary, Rajatashuvra; Kangusamy, Boopathi; Thomas, Beena E; Kallam, Srinivasan; Girish, C P K
2008-12-01
To characterize and describe patterns of HIV, sexually transmitted infections (STI) and sexual behaviour of male clients of female sex workers (FSW). A cross-sectional study was conducted among 4821 clients of FSW from 12 districts in three states in India: Andhra Pradesh, Maharashtra and Tamil Nadu. A structured questionnaire was administered to elicit demographic characteristics and sexual behavioural patterns. Blood and urine samples were tested for HIV, syphilis and herpes simplex type 2 serology, gonococcal and chlamydial infection. The median age of clients surveyed was 30 years; 57% were married and 64% had a steady sexual partner; 61% had sex with more than one FSW and 39% had four or more sexual encounters in the past month. The prevalence of HIV ranged from 2.0% to 10.9%, syphilis ranged from 3.1% to 10.1%; gonorrhoea and chlamydia ranged between 0% and 4.5%. Clients older than 30 years [odds ratio (OR) 1.65; 95% confidence interval (CI) 1.33-2.05] and having a different mix of commercial and non-commercial partners (OR 1.56; 95% CI 1.25-1.96) had a higher volume of sex acts with FSW. Inconsistent condom use with FSW was significantly associated with older clients (OR 4.2; 95% CI 3.33-5.29), illiteracy (OR 1.39; 95% CI 1.14-1.69), age <18 years at first paid sex (OR 1.83; 95% CI 1.24-2.70) and having different FSW partners in the past month (OR 1.64; 95% CI 1.23-2.18). Clients of FSW studied here constitute a significant bridge group for HIV and other STI, because of their high volume of different sexual partners and very low consistent condom use. HIV prevention programmes need to address male clients.
Friction Stir Welding Development at NASA, Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
McGill, Preston; Gentz, Steve (Technical Monitor)
2001-01-01
Friction stir welding (FSW) is a solid state process that pan be used to join materials without melting. The process was invented by The Welding Institute (TWI), Cambridge, England. Friction stir welding exhibits several advantages over fusion welding in that it produces welds with fewer defects and higher joint efficiency and is capable of joining alloys that are generally considered non-weldable with a fusion weld process. In 1994, NASA-Marshall began collaborating with TWI to transform FSW from a laboratory curiosity to a viable metal joining process suitable for manufacturing hardware. While teamed with TWI, NASA-Marshall began its own FSW research and development effort to investigate possible aerospace applications for the FSW process. The work involved nearly all aspects of FSW development, including process modeling, scale-up issues, applications to advanced materials and development of tooling to use FSW on components of the Space Shuttle with particular emphasis on aluminum tanks. The friction stir welding process involves spinning a pin-tool at an appropriate speed, plunging it into the base metal pieces to be joined, and then translating it along the joint of the work pieces. In aluminum alloys the rotating speed typically ranges from 200 to 400 revolutions per minute and the translation speed is approximately two to five inches per minute. The pin-tool is inserted at a small lead angle from the axis normal to the work piece and requires significant loading along the axis of the tool. An anvil or reaction structure is required behind the welded material to react the load along the axis of the pin tool. The process requires no external heat input, filler material, protective shielding gas or inert atmosphere typical of fusion weld processes. The FSW solid-state weld process has resulted in aluminum welds with significantly higher strengths, higher joint efficiencies and fewer defects than fusion welds used to join similar alloys.
A study on laser-based ultrasonic technique by the use of guided wave tomographic imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Junpil, E-mail: jpp@pusan.ac.kr; Lim, Juyoung, E-mail: jpp@pusan.ac.kr; Cho, Younho
2015-03-31
Guided wave tests are impractical for investigating specimens with limited accessibility and coarse surfaces or geometrically complicated features. A non-contact setup with a laser ultrasonic transmitter and receiver is the classic attractive for guided wave inspection. The present work was done to develop a non-contact guided-wave tomography technique by laser ultrasonic technique in a plate-like structure. A method for Lam wave generation and detection in an aluminum plate with a pulse laser ultrasonic transmitter and a Michelson interferometer receiver has been developed. In the images obtained by laser scanning, the defect shape and area showed good agreement with the actualmore » defect. The proposed approach can be used as a non-contact-based online inspection and monitoring technique.« less
Modular, Autonomous Command and Data Handling Software with Built-In Simulation and Test
NASA Technical Reports Server (NTRS)
Cuseo, John
2012-01-01
The spacecraft system that plays the greatest role throughout the program lifecycle is the Command and Data Handling System (C&DH), along with the associated algorithms and software. The C&DH takes on this role as cost driver because it is the brains of the spacecraft and is the element of the system that is primarily responsible for the integration and interoperability of all spacecraft subsystems. During design and development, many activities associated with mission design, system engineering, and subsystem development result in products that are directly supported by the C&DH, such as interfaces, algorithms, flight software (FSW), and parameter sets. A modular system architecture has been developed that provides a means for rapid spacecraft assembly, test, and integration. This modular C&DH software architecture, which can be targeted and adapted to a wide variety of spacecraft architectures, payloads, and mission requirements, eliminates the current practice of rewriting the spacecraft software and test environment for every mission. This software allows missionspecific software and algorithms to be rapidly integrated and tested, significantly decreasing time involved in the software development cycle. Additionally, the FSW includes an Onboard Dynamic Simulation System (ODySSy) that allows the C&DH software to support rapid integration and test. With this solution, the C&DH software capabilities will encompass all phases of the spacecraft lifecycle. ODySSy is an on-board simulation capability built directly into the FSW that provides dynamic built-in test capabilities as soon as the FSW image is loaded onto the processor. It includes a six-degrees- of-freedom, high-fidelity simulation that allows complete closed-loop and hardware-in-the-loop testing of a spacecraft in a ground processing environment without any additional external stimuli. ODySSy can intercept and modify sensor inputs using mathematical sensor models, and can intercept and respond to actuator commands. ODySSy integration is unique in that it allows testing of actual mission sequences on the flight vehicle while the spacecraft is in various stages of assembly, test, and launch operations all without any external support equipment or simulators. The ODySSy component of the FSW significantly decreases the time required for integration and test by providing an automated, standardized, and modular approach to integrated avionics and component interface and functional verification. ODySSy further provides the capability for on-orbit support in the form of autonomous mission planning and fault protection.
NASA Astrophysics Data System (ADS)
Zarubin, V.; Bychkov, A.; Simonova, V.; Zhigarkov, V.; Karabutov, A.; Cherepetskaya, E.
2018-05-01
In this paper, a technique for reflection mode immersion 2D laser-ultrasound tomography of solid objects with piecewise linear 2D surface profiles is presented. Pulsed laser radiation was used for generation of short ultrasonic probe pulses, providing high spatial resolution. A piezofilm sensor array was used for detection of the waves reflected by the surface and internal inhomogeneities of the object. The original ultrasonic image reconstruction algorithm accounting for refraction of acoustic waves at the liquid-solid interface provided longitudinal resolution better than 100 μm in the polymethyl methacrylate sample object.
Fleming, Paul J; Patterson, Thomas L; Chavarin, Claudia V; Semple, Shirley J; Magis-Rodriguez, Carlos; Pitpitan, Eileen V
2017-08-01
We use data collected from a sample of 400 male clients of female sex workers (FSW) to examine their HIV testing behavior. We present frequencies of HIV testing and used bivariate and multivariable analyses to assess its socio-demographic, behavioral, and psychosocial correlates. We found that the majority (55 %) of male clients of FSW in Tijuana, Mexico had never had an HIV test and the prevalence of HIV testing within the past year was low (9 %). In multivariable analyses, significant correlates of having ever tested for HIV were higher age, higher HIV knowledge score, lower sexual compulsiveness score, lower misogynistic attitudes score, having a condom break during sex with a FSW, and higher frequency of sex with a FSW while she was high. Our findings represent an important starting point for developing effective interventions to address the need to promote HIV testing among this population.
Analysing the strength of friction stir welded dissimilar aluminium alloys using Sugeno Fuzzy model
NASA Astrophysics Data System (ADS)
Barath, V. R.; Vaira Vignesh, R.; Padmanaban, R.
2018-02-01
Friction stir welding (FSW) is a promising solid state joining technique for aluminium alloys. In this study, FSW trials were conducted on two dissimilar plates of aluminium alloy AA2024 and AA7075 by varying the tool rotation speed (TRS) and welding speed (WS). Tensile strength (TS) of the joints were measured and a Sugeno - Fuzzy model was developed to interconnect the FSW process parameters with the tensile strength. From the developed model, it was observed that the optimum heat generation at WS of 15 mm.min-1 and TRS of 1050 rpm resulted in dynamic recovery and dynamic recrystallization of the material. This refined the grains in the FSW zone and resulted in peak tensile strength among the tested specimens. Crest parabolic trend was observed in tensile strength with variation of TRS from 900 rpm to 1200 rpm and TTS from 10 mm.min-1 to 20 mm.min-1.
Control of Structure in Conventional Friction Stir Welds through a Kinematic Theory of Metal Flow
NASA Technical Reports Server (NTRS)
Rubisoff, H.A.; Schneider, J.A.; Nunes, A.C.
2009-01-01
In friction stir welding (FSW), a rotating pin is translated along a weld seam so as to stir the sides of the seam together. Metal is prevented from flowing up the pin, which would result in plowing/cutting instead of welding, by a shoulder on the pin. In conventional FSW, the weld metal rests on an "anvil", which supports the heavy "plunge" load on the tool. In this study, both embedded tungsten wires along and copper plating on the faying surfaces were used to trace the flow of AA2219 weld metal around the C-FSW tool. The effect of tool rotational speed, travel speed, plunge load, and pin thread pitch on the resulting weld metal flow was evaluated. Plan, longitudinal, and transverse section x-ray radiographs were examined to trace the metal flow paths. The results are interpreted in terms of a kinematic theory of metal flow in FSW.
HIV testing behaviors among female sex workers in Southwest China.
Hong, Yan; Zhang, Chen; Li, Xiaoming; Fang, Xiaoyi; Lin, Xiuyun; Zhou, Yuejiao; Liu, Wei
2012-01-01
Despite the recognized importance of HIV testing in prevention, care and treatment, HIV testing remains low in China. Millions of female sex workers (FSW) play a critical role in China's escalating HIV epidemic. Limited data are available regarding HIV testing behavior among this at-risk population. This study, based on a cross-sectional survey of 1,022 FSW recruited from communities in Southwest China, attempted to address the literature gap. Our data revealed that 48% of FSW ever took HIV testing; older age, less education, working in higher-income commercial sex venues and better HIV knowledge were associated with HIV testing. Those who never took HIV testing were more likely to engage in high-risk behaviors including inconsistent condom use with clients and stable partners. A number of psychological and structural barriers to testing were also reported. We call for culturally appropriate interventions to reduce HIV risks and promote HIV testing for vulnerable FSW in China.
Homogeneity of Mechanical Properties of Underwater Friction Stir Welded 2219-T6 Aluminum Alloy
NASA Astrophysics Data System (ADS)
Liu, H. J.; Zhang, H. J.; Yu, L.
2011-11-01
Underwater friction stir welding (FSW) has been demonstrated to be available for the improvement in tensile strength of normal FSW joints. In order to illuminate the intrinsic reason for strength improvement through underwater FSW, a 2219 aluminum alloy was underwater friction stir welded and the homogeneity of mechanical properties of the joint was investigated by dividing the joint into three layers. The results indicate that the tensile strength of the three layers of the joint is all improved by underwater FSW, furthermore, the middle and lower layers have larger extent of strength improvement than the upper layer, leading to an increase in the homogeneity of mechanical properties of the joint. The minimum hardness value of each layer, especially the middle and lower layers, is improved under the integral water cooling effect, which is the intrinsic reason for the strength improvement of underwater joint.
King, Elizabeth J; Maman, Suzanne; Bowling, J Michael; Moracco, Kathryn E; Dudina, Viktoria
2013-10-01
Stigma associated with HIV and risk behaviors is known to be a barrier to health care access for many populations. Less is known about female sex workers (FSW) in Russia, a population that is especially vulnerable to HIV-infection, and yet hard-to-reach for service providers. We administered a questionnaire to 139 FSW to better understand how stigma and discrimination influence HIV service utilization. Logistic regression analysis indicated that HIV-related stigma is negatively associated with uptake of HIV testing, while sex work-related stigma is positively associated with HIV testing. HIV-positive FSW are more likely than HIV-negative FSW to experience discrimination in health care settings. While decreasing societal stigma should be a long-term goal, programs that foster inclusion of marginalized populations in Russian health care settings are urgently needed.
Augusto, Ângelo do Rosário; Young, Peter W; Horth, Roberta Z; Inguane, Celso; Sathane, Isabel; Ngale, Katia; Benedetti, Marcos; Cummings, Beverley; Botão, Carlos Francisco Sande; Baltazar, Cynthia Amino Semá; Frank, Heidi; Fagan, Jennifer; Fisher Raymond, Henry; McFarland, Willi
2016-04-01
This is the first integrated biological and behavioral survey among female sex workers (FSW) in Mozambique. Using respondent-driven sampling, 400, 411 and 429 FSW were enrolled respectively in Maputo, Beira and Nampula in 2011-2012. Estimates were produced using RDSAT 7.1. HIV prevalence was 31.2, 23.6, and 17.8 % in each location respectively. Among HIV-positive FSW, 48.1, 79.8 and 89.6 % in each city, were unaware of their serostatus. Condom use at last sex with a client was 85.8, 73.4 and 62.8 % among FSW, respectively. HIV was associated with current age, age of first sex for money, low educational level, and having had a genital ulcer in the last 6 months. Results suggest the urgent need to increase behavioral and structural interventions in this key population.
Friction Stir Welding of SiC/Aluminum Metal Matrix Composites
NASA Technical Reports Server (NTRS)
Lee, Jonathan A.
1999-01-01
Friction Stir Welding (FSW) is a new solid state process for joining metals by plasticizing and consolidating materials around the bond line using thermal energy producing from frictional forces. A feasibility study for FSW of Metal Matrix Composites (MMC) was investigated using aluminum 6092 alloy reinforced with 17% SiC particulates. FSW process consists of a special rotating pin tool that is positioned to plunge into the MMC surface at the bond line. As the tool rotates and move forward along the bond line, the material at the bond line is heated up and forced to flow around the rotating tip to consolidate on the tip's backside to form a solid state joint. FSW has the potential for producing sound welds with MMC because the processing temperature occurs well below the melting point of the metal matrix; thereby eliminating the reinforcement-to-matrix solidification defects, reducing the undesirable chemical reactions and porosity problems.
Cwikel, Julie G; Lazer, Tal; Press, Fernanda; Lazer, Simcha
2008-03-01
Women who work commercially in sex work (female sex workers [FSW]) are considered a high-risk group for sexually transmissible infections (STI), yet the level of reported pathogens varies in studies around the world. This study reviewed STI rates reported in 42 studies of FSW around the world published between 1995 and 2006 and analysed the trends and types of populations surveyed, emphasising difficult to access FSW populations. Studies were retrieved by PUBMED and other search engines and were included if two or more pathogens were studied and valid laboratory methods were reported. The five most commonly assessed pathogens were Neisseria gonorrhea (prevalence 0.5-41.3), Chlamydia trachomatis (0.61-46.2), Treponema pallidum (syphilis; 1.5-60.5), HIV (0-76.6), and Trichomonas vaginalis (trichomoniasis; 0.11-51.0). Neisseria gonorrhea and C. trachomatis were the most commonly tested pathogens and high prevalence levels were found in diverse areas of the world. HIV was highly prevalent mostly in African countries. Although human papillomavirus infection was surveyed in few studies, prevalence rates were very high and its aetiological role in cervical cancer warrant its inclusion in future FSW monitoring. Hard-to-access FSW groups tended to have higher rates of STI. The five most commonly detected pathogens correspond to those that are highly prevalent in the general population, however there is an urgent need to develop rapid testing diagnostics for all five pathogens to increase prevention and treatment, especially in outreach programs to the most vulnerable groups among FSW.
Exploring dynamics of anal sex among female sex workers in Andhra Pradesh.
Tucker, Saroj; Krishna, Rama; Prabhakar, Parimi; Panyam, Swarup; Anand, Pankaj
2012-01-01
The anal sex among heterosexual couples is on the rise as reported in many scientific studies. Considering that unprotected anal sex has higher risk of human immunodeficiency virus (HIV) transmission than the vaginal sex, we undertook a study to understand the anal sex practices among Female Sex Workers (FSW). The study was conducted among FSW attending 11 randomly selected sexually transmitted infection (STI) clinics in Bill and Melinda Gates supported targeted interventions in Andhra Pradesh. A structured questionnaire was administered to the 555 FSW attending these clinics by project clinic counselors. Informed consent was obtained from all the study participants. Engaging in anal sex was self reported by 22% of sex workers, though demand from clients was reported to be much higher (40%). The reasons for anal sex practices included more money (61%), clout/influence of the client (45%), risk of losing client (27%), and forced sex (1.2%). Factors associated with anal sex were higher number of clients, higher duration of sex work, higher income, and older age group. Associated risks perceived by FSW were bleeding and injury to anal canal (98%) while only 28% associated it with higher HIV transmission risk. Reported Condom and lubricant use was about 88% and 39% respectively. The study shows that there is frequent anal sex, inconsistent condom and infrequent lubricant usage, economic and physical coercion, and low awareness of STI/HIV transmission risk among FSW, which have serious implications for HIV prevention programmes. There is a need to focus on anal sex education and use of lubricants along with condoms during anal sex in FSW-targeted interventions in AP.
Aquarius' Object-Oriented, Plug and Play Component-Based Flight Software
NASA Technical Reports Server (NTRS)
Murray, Alexander; Shahabuddin, Mohammad
2013-01-01
The Aquarius mission involves a combined radiometer and radar instrument in low-Earth orbit, providing monthly global maps of Sea Surface Salinity. Operating successfully in orbit since June, 2011, the spacecraft bus was furnished by the Argentine space agency, Comision Nacional de Actividades Espaciales (CONAE). The instrument, built jointly by NASA's Caltech/JPL and Goddard Space Flight Center, has been successfully producing expectation-exceeding data since it was powered on in August of 2011. In addition to the radiometer and scatterometer, the instrument contains an command & data-handling subsystem with a computer and flight software (FSW) that is responsible for managing the instrument, its operation, and its data. Aquarius' FSW is conceived and architected as a Component-based system, in which the running software consists of a set of Components, each playing a distinctive role in the subsystem, instantiated and connected together at runtime. Component architectures feature a well-defined set of interfaces between the Components, visible and analyzable at the architectural level (see [1]). As we will describe, this kind of an architecture offers significant advantages over more traditional FSW architectures, which often feature a monolithic runtime structure. Component-based software is enabled by Object-Oriented (OO) techniques and languages, the use of which again is not typical in space mission FSW. We will argue in this paper that the use of OO design methods and tools (especially the Unified Modeling Language), as well as the judicious usage of C++, are very well suited to FSW applications, and we will present Aquarius FSW, describing our methods, processes, and design, as a successful case in point.
NASA Astrophysics Data System (ADS)
Sharma, Nidhi; Khan, Zahid A.; Siddiquee, Arshad Noor; Shihab, Suha K.; Atif Wahid, Mohd
2018-04-01
Copper (Cu) is predominantly used material as a conducting element in electrical and electronic components due to its high conductivity. Aluminum (Al) being lighter in weight and more conductive on weight basis than that of Cu is able to replace or partially replace Cu to make lighter and cost effective electrical components. Conventional methods of joining Al to Cu, such as, fusion welding process have many shortcomings. Friction Stir Welding (FSW) is a solid state welding process which overcomes the shortcoming of the fusion welding. FSW parameters affect the mechanical and electrical properties of the joint. This study aims to evaluate the effect of different process parameters such as shoulder diameter, pin offset, welding and rotational speed on the microstructure and electrical conductivity of the dissimilar Al-Cu joint. FSW is performed using cylindrical pin profile, and four process parameters. Each parameter at different levels is varied according to Taguchi’s L18 standard orthogonal array. It is found that the electrical conductivity of the FSWed joints are equal to that of aluminum at all the welded sections. FSW is found to be an effective technique to join Al to Cu without compromising with the electrical properties. However, the electrical conductivity gets influenced by the process parameters in the stir zone. The optimal combination of the FSW parameters for maximum electrical conductivity is determined. The analysis of variance (ANOVA) technique applied on stir zone suggests that the rotational speed and tool pin offset are the significant parameters to influence the electrical conductivity.
Echocardiographic strain and strain-rate imaging: a new tool to study regional myocardial function.
D'hooge, Jan; Bijnens, Bart; Thoen, Jan; Van de Werf, Frans; Sutherland, George R; Suetens, Paul
2002-09-01
Ultrasonic imaging is the noninvasive clinical imaging modality of choice for diagnosing heart disease. At present, two-dimensional ultrasonic grayscale images provide a relatively cheap, fast, bedside method to study the morphology of the heart. Several methods have been proposed to assess myocardial function. These have been based on either grayscale or motion (velocity) information measured in real-time. However, the quantitative assessment of regional myocardial function remains an important goal in clinical cardiology. To do this, ultrasonic strain and strain-rate imaging have been introduced. In the clinical setting, these techniques currently only allow one component of the true three-dimensional deformation to be measured. Clinical, multidimensional strain (rate) information can currently thus only be obtained by combining data acquired using different transducer positions. Nevertheless, given the appropriate postprocessing, the clinical value of these techniques has already been shown. Moreover, multidimensional strain and strain-rate estimation of the heart in vivo by means of a single ultrasound acquisition has been shown to be feasible. In this paper, the new techniques of ultrasonic strain rate and strain imaging of the heart are reviewed in terms of definitions, data acquisition, strain-rate estimation, postprocessing, and parameter extraction. Their clinical validation and relevance will be discussed using clinical examples on relevant cardiac pathology. Based on these examples, suggestions are made for future developments of these techniques.
Method for Ultrasonic Imaging and Device for Performing the Method
NASA Technical Reports Server (NTRS)
Madaras, Eric I. (Inventor)
1997-01-01
A method for ultrasonic imaging of interior structures and flaws in a test specimen with a smooth or irregular contact surfaces, in which an ultrasonic transducer is coupled acoustically to the contact surface via a plurality of ultrasonic wave guides with equal delay times. The wave guides are thin and bendable, so they adapt to variations in the distance between the transducer and different parts of the contact surface by bending more or less. All parts of the irregular contact surface accordingly receive sound waves that are in phase, even when the contact surface is irregular, so a coherent sound wave is infused in the test specimen. The wave guides can be arranged in the form of an ultrasonic brush, with a flat head for coupling to a flat transducer, and free bristles that can be pressed against the test specimen. By bevelling the bristle ends at a suitable angle, shear mode waves can be infused into the test specimen from a longitudinal mode transducer.
NASA Astrophysics Data System (ADS)
Hay, D. Robert; Brassard, Michel; Matthews, James R.; Garneau, Stephane; Morchat, Richard
1995-06-01
The convergence of a number of contemporary technologies with increasing demands for improvements in inspection capabilities in maritime applications has created new opportunities for ultrasonic inspection. An automated ultrasonic inspection and data collection system APHIUS (automated pressure hull intelligent ultrasonic system), incorporates hardware and software developments to meet specific requirements for the maritime vessels, in particular, submarines in the Canadian Navy. Housed within a hardened portable computer chassis, instrumentation for digital ultrasonic data acquisition and transducer position measurement provide new capabilities that meet more demanding requirements for inspection of the aging submarine fleet. Digital data acquisition enables a number of new important capabilites including archiving of the complete inspection session, interpretation assistance through imaging, and automated interpretation using artificial intelligence methods. With this new reliable inspection system, in conjunction with a complementary study of the significance of real defect type and location, comprehensive new criteria can be generated which will eliminate unnecessary defect removal. As a consequence, cost savings will be realized through shortened submarine refit schedules.
Han, Lifeng; Zhou, Chu; Li, Zhijun; Poon, Adrienne N; Rou, Keming; Fuller, Serena; Li, Yan; Shen, Limei; Kang, Dianmin; Huang, Lu; Liao, Meizhen; Fu, Xiaobing; Shepard, Colin; Wu, Zunyou; Bulterys, Marc
2016-06-01
To better understand risk behaviours and factors associated with low-fee female sex workers (FSW) and support HIV/sexually transmitted infections (STI) epidemic control among this key population in China. A cross-sectional study using convenience sampling to recruit 1487 eligible low-fee and medium-fee FSW was conducted in 2012 in three provinces. The participants were interviewed using a structured questionnaire and tested for HIV-1, herpes simplex virus (HSV)-2 and syphilis antibody. Log-binomial modelling was used to estimate prevalence ratios (PR) and examine factors associated with low-fee sex work. Prevalence of HIV-1, syphilis and HSV-2 antibody positive were 0.5%, 4.8% and 27.8%, respectively. Low-fee FSW were more likely to have HSV-2 infection (adjusted prevalence ratio (APR)=1.3, 95% CI 1.1 to 1.7), but not more likely to have HIV-1 and syphilis infection compared with medium-fee FSW. Compared with medium-fee FSW, low-fee FSW were more likely to be ≥35 years of age (APR=2.1, 95% CI 1.3 to 3.6), engage in sex work ≥6 days/per week (APR=1.7, 95% CI 1.2 to 2.6), have ≥3 clients per day (APR=2.2, 95% CI 1.5 to 3.3), have clients decide condom use (APR=1.6, 95% CI 1.1 to 2.3), fail to persuade clients to use condoms (APR=1.6, 95% CI 1.1 to 2.6), express willingness to have unprotected sex in return for receipt of a higher fee (APR=1.8, 95% CI 1.2 to 2.8), have had genital symptoms in the past year (APR=1.4, 95% CI 1.1 to 1.8) and have migrated from another city. Low-fee FSW in China have unique risks for acquiring HIV/STI, in part due to greater economic pressures. Tailored interventions targeting low-fee FSW and incorporating their prevailing perception of HIV/STI risks and condom use negotiation challenges that they face are urgently needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Friction Stir Welding of Metal Matrix Composites for use in aerospace structures
NASA Astrophysics Data System (ADS)
Prater, Tracie
2014-01-01
Friction Stir Welding (FSW) is a relatively nascent solid state joining technique developed at The Welding Institute (TWI) in 1991. The process was first used at NASA to weld the super lightweight external tank for the Space Shuttle. Today FSW is used to join structural components of the Delta IV, Atlas V, and Falcon IX rockets as well as the Orion Crew Exploration Vehicle. A current focus of FSW research is to extend the process to new materials which are difficult to weld using conventional fusion techniques. Metal Matrix Composites (MMCs) consist of a metal alloy reinforced with ceramics and have a very high strength to weight ratio, a property which makes them attractive for use in aerospace and defense applications. MMCs have found use in the space shuttle orbiter's structural tubing, the Hubble Space Telescope's antenna mast, control surfaces and propulsion systems for aircraft, and tank armors. The size of MMC components is severely limited by difficulties encountered in joining these materials using fusion welding. Melting of the material results in formation of an undesirable phase (formed when molten Aluminum reacts with the reinforcement) which leaves a strength depleted region along the joint line. Since FSW occurs below the melting point of the workpiece material, this deleterious phase is absent in FSW-ed MMC joints. FSW of MMCs is, however, plagued by rapid wear of the welding tool, a consequence of the large discrepancy in hardness between the steel tool and the reinforcement material. This work characterizes the effect of process parameters (spindle speed, traverse rate, and length of joint) on the wear process. Based on the results of these experiments, a phenomenological model of the wear process was constructed based on the rotating plug model for FSW. The effectiveness of harder tool materials (such as Tungsten Carbide, high speed steel, and tools with diamond coatings) to combat abrasive wear is explored. In-process force, torque, and vibration signals are analyzed to assess the feasibility of on-line monitoring of tool shape changes as a result of wear (an advancement which would eliminate the need for off-line evaluation of tool condition during joining). Monitoring, controlling, and reducing tool wear in FSW of MMCs is essential to the implementation of these materials in structures (such as launch vehicles) where they would be of maximum benefit.
NASA Astrophysics Data System (ADS)
Xu, Weichao; Shen, Jingling; Zhang, Cunlin; Tao, Ning; Feng, Lichun
2008-03-01
The applications of ultrasonic infrared thermal wave nondestructive evaluation for crack detection of several materials, which often used in aviation alloy. For instance, steel and carbon fiber. It is difficult to test cracks interfacial or vertical with structure's surface by the traditional nondestructive testing methods. Ultrasonic infrared thermal wave nondestructive testing technology uses high-power and low-frequency ultrasonic as heat source to excite the sample and an infrared video camera as a detector to detect the surface temperature. The ultrasonic emitter launch pulses of ultrasonic into the skin of the sample, which causes the crack interfaces to rub and dissipate energy as heat, and then caused local increase in temperature at one of the specimen surfaces. The infrared camera images the returning thermal wave reflections from subsurface cracks. A computer collects and processes the thermal images according to different properties of samples to get the satisfied effect. In this paper, a steel plate with fatigue crack we designed and a juncture of carbon fiber composite that has been used in a space probe were tested and get satisfying results. The ultrasonic infrared thermal wave nondestructive detection is fast, sensitive for cracks, especially cracks that vertical with structure's surface. It is significative for nondestructive testing in manufacture produce and application of aviation, cosmography and optoelectronics.
NASA Astrophysics Data System (ADS)
Santos, Serge Dos; Farova, Zuzana; Kus, Vaclav; Prevorovsky, Zdenek
2012-05-01
This paper examines possibilities of using Nonlinear Elastic Wave Spectroscopy (NEWS) methods in dental investigations. Themain task consisted in imaging cracks or other degradation signatures located in dentin close to the Enamel-Dentine Junction (EDJ). NEWS approach was investigated experimentally with a new bi-modal acousto-optic set-up based on the chirp-coded nonlinear ultrasonic time reversal (TR) concepts. Complex internal structure of the tooth is analyzed by the TR-NEWS procedure adapted to tomography-like imaging of the tooth damages. Ultrasonic instrumentation with 10 MHz bandwidth has been set together including laser vibrometer used to detect responses of the tooth on its excitation carried out by a contact piezoelectric transducer. Bi-modal TR-NEWS images of the tooth were created before and after focusing, which resulted from the time compression. The polar B-scan of the tooth realized with TR-NEWS procedure is suggested to be applied as a new echodentography imaging.
NASA Astrophysics Data System (ADS)
Yamakoshi, Yoshiki; Yamamoto, Atsushi; Kasahara, Toshihiro; Iijima, Tomohiro; Yuminaka, Yasushi
2015-07-01
We have proposed a quantitative shear wave imaging technique for continuous shear wave excitation. Shear wave wavefront is observed directly by color flow imaging using a general-purpose ultrasonic imaging system. In this study, the proposed method is applied to experiments in vivo, and shear wave maps, namely, the shear wave phase map, which shows the shear wave propagation inside the medium, and the shear wave velocity map, are observed for the skeletal muscle in the shoulder. To excite the shear wave inside the skeletal muscle of the shoulder, a hybrid ultrasonic wave transducer, which combines a small vibrator with an ultrasonic wave probe, is adopted. The shear wave velocity of supraspinatus muscle, which is measured by the proposed method, is 4.11 ± 0.06 m/s (N = 4). This value is consistent with those obtained by the acoustic radiation force impulse method.
Imaging and analysis of individual cavitation microbubbles around dental ultrasonic scalers.
Vyas, N; Dehghani, H; Sammons, R L; Wang, Q X; Leppinen, D M; Walmsley, A D
2017-11-01
Cavitation is a potentially effective and less damaging method of removing biofilm from biomaterial surfaces. The aim of this study is to characterise individual microbubbles around ultrasonic scaler tips using high speed imaging and image processing. This information will provide improved understanding on the disruption of dental biofilm and give insights into how the instruments can be optimised for ultrasonic cleaning. Individual cavitation microbubbles around ultrasonic scalers were analysed using high speed recordings up to a million frames per second with image processing of the bubble movement. The radius and rate of bubble growth together with the collapse was calculated by tracking multiple points on bubbles over time. The tracking method to determine bubble speed demonstrated good inter-rater reliability (intra class correlation coefficient: 0.993) and can therefore be a useful method to apply in future studies. The bubble speed increased over its oscillation cycle and a maximum of 27ms -1 was recorded during the collapse phase. The maximum bubble radii ranged from 40 to 80μm. Bubble growth was observed when the ultrasonic scaler tip receded from an area and similarly bubble collapse was observed when the tip moved towards an area, corresponding to locations of low pressure around the scaler tip. Previous work shows that this cavitation is involved in biofilm removal. Future experimental work can be based on these findings by using the protocols developed to experimentally analyse cavitation around various clinical instruments and comparing with theoretical calculations. This will help to determine the main cleaning mechanisms of cavitation and how clinical instruments such as ultrasonic scalers can be optimised. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Ultrasonic imaging system for in-process fabric defect detection
Sheen, Shuh-Haw; Chien, Hual-Te; Lawrence, William P.; Raptis, Apostolos C.
1997-01-01
An ultrasonic method and system are provided for monitoring a fabric to identify a defect. A plurality of ultrasonic transmitters generate ultrasonic waves relative to the fabric. An ultrasonic receiver means responsive to the generated ultrasonic waves from the transmitters receives ultrasonic waves coupled through the fabric and generates a signal. An integrated peak value of the generated signal is applied to a digital signal processor and is digitized. The digitized signal is processed to identify a defect in the fabric. The digitized signal processing includes a median value filtering step to filter out high frequency noise. Then a mean value and standard deviation of the median value filtered signal is calculated. The calculated mean value and standard deviation are compared with predetermined threshold values to identify a defect in the fabric.
Design and application of a small size SAFT imaging system for concrete structure
NASA Astrophysics Data System (ADS)
Shao, Zhixue; Shi, Lihua; Shao, Zhe; Cai, Jian
2011-07-01
A method of ultrasonic imaging detection is presented for quick non-destructive testing (NDT) of concrete structures using synthesized aperture focusing technology (SAFT). A low cost ultrasonic sensor array consisting of 12 market available low frequency ultrasonic transducers is designed and manufactured. A channel compensation method is proposed to improve the consistency of different transducers. The controlling devices for array scan as well as the virtual instrument for SAFT imaging are designed. In the coarse scan mode with the scan step of 50 mm, the system can quickly give an image display of a cross section of 600 mm (L) × 300 mm (D) by one measurement. In the refined scan model, the system can reduce the scan step and give an image display of the same cross section by moving the sensor array several times. Experiments on staircase specimen, concrete slab with embedded target, and building floor with underground pipe line all verify the efficiency of the proposed method.
Novel PMN-PT free standing film for high frequency (80MHz) intravascular ultrasonic imaging
Li, Xiang; Zhou, Qifa; Shung, K. Kirk; Shih, Wei-Heng; Shih, Wan Y.
2011-01-01
[Pb(Mg1/3Nb2/3)O3]0.63[PbTiO3]0.37 (PMN-PT) free standing film of comparable piezoelectric property to bulk PMN-PT with a thickness of 33 μm has been fabricated using a modified precursor coating approach. At 1 KHz, the dielectric constant and loss were 4,160 and 0.0291, respectively. The remnant polarization and coercive field were 28 μC/cm2 and 18.43 kV/cm. The electromechanical coupling coefficient kt was measured to be 0.55, which was close to that of bulk PMN-PT single crystal material. A high frequency (80 MHz) miniature ultrasonic transducer with high sensitivity was fabricated from this film. In vitro imaging of a rabbit aorta was performed to demonstrate the application of this material to intravascular ultrasound imaging at 80 MHz. Compared to a 35 MHz ultrasonic image, the 80 MHz image showed superior resolution and contrast. PMID:22083761
NASA Technical Reports Server (NTRS)
Roth, Don J.; Hepp, Aloysius F.; Deguire, Mark R.; Dolhert, Leonard E.
1991-01-01
The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu30(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Deguire, Mark R.; Dolhert, Leonard E.; Hepp, Aloysius F.
1991-01-01
The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu3O(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.
TEM study of the FSW nugget in AA2195-T81
NASA Technical Reports Server (NTRS)
Schneider, J. A.; Nunes, A. C., Jr.; Chen, P. S.; Steele, G.
2004-01-01
During fiiction stir welding (FSW) the material being joined is subjected to a thermal- mechanical process in which the temperature, strain and strain rates are not completely understood. To produce a defect fiee weld, process parameters for the weld and tool pin design must be chosen carefully. The ability to select the weld parameters based on the thermal processing requirements of the material, would allow optimization of mechanical properties in the weld region. In this study, an attempt is made to correlate the microstructure with the variation in thermal history the material experiences during the FSW process.
Cann, Adam P; MacEachen, Ellen; Vandervoort, Anthony A
2008-01-01
The recent trend towards cooperative management and prevention of workplace injuries has introduced numerous health and safety actors to the workplace with varying amounts and types of expertise. The purpose of this qualitative research project was to explore the understandings of risk as experienced by food service workers (FSW) and how these compare with an 'expert' in risk assessment. In total 13 FSW, selected based on age, work location, and gender, and one experienced Ergonomist participated in the study. In-depth semi-structured telephone interviews were conducted with each participant and transcripts of the interviews were analyzed using thematic analysis by drawing on methods closely related to grounded theory. The findings of this study indicated that the risks for occupational injury as experienced by FSW were multi-dimensional in nature representing not only the physical requirements of the individual's job, but also the social interactions of the FSW with their coworkers, management, and the organization. FSW were also found to be a rich source of knowledge and experience concerning occupational risk and may be under-utilized when designing interventions. The results of this study support a cooperative team approach to reduce the risks of injury in the workplace, with a specific emphasis on inclusion of the worker.
Nonlinear propagation in ultrasonic fields: measurements, modelling and harmonic imaging.
Humphrey, V F
2000-03-01
In high amplitude ultrasonic fields, such as those used in medical ultrasound, nonlinear propagation can result in waveform distortion and the generation of harmonics of the initial frequency. In the nearfield of a transducer this process is complicated by diffraction effects associated with the source. The results of a programme to study the nonlinear propagation in the fields of circular, focused and rectangular transducers are described, and comparisons made with numerical predictions obtained using a finite difference solution to the Khokhlov-Zabolotskaya-Kuznetsov (or KZK) equation. These results are extended to consider nonlinear propagation in tissue-like media and the implications for ultrasonic measurements and ultrasonic heating are discussed. The narrower beamwidths and reduced side-lobe levels of the harmonic beams are illustrated and the use of harmonics to form diagnostic images with improved resolution is described.
NASA Technical Reports Server (NTRS)
Miller, James G.
1997-01-01
In this Progress Report, we describe our further development of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns transmitted through water only and transmitted through water and a thin woven composite. All images of diffraction patterns have been included on the accompanying CD-ROM in the JPEG format and Adobe TM Portable Document Format (PDF), in addition to the inclusion of hardcopies of the images contained in this report. In our previous semi-annual Progress Report (NAG 1-1848, December, 1996), we proposed a simple model to simulate the effect of a thin woven composite on an insonifying ultrasonic pressure field. This initial approach provided an avenue to begin development of a robust measurement method for nondestructive evaluation of anisotropic materials. In this Progress Report, we extend that work by performing experimental measurements on a single layer of a five-harness biaxial woven composite to investigate how a thin, yet architecturally complex, material interacts with the insonifying ultrasonic field. In Section 2 of this Progress Report we describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. We also briefly describe the thin composite specimen investigated. Section 3 details the analysis of the experimental data followed by the experimental results in Section 4. Finally, a discussion of the observations and conclusions is found in Section 5.
Bulk-wave ultrasonic propagation imagers
NASA Astrophysics Data System (ADS)
Abbas, Syed Haider; Lee, Jung-Ryul
2018-03-01
Laser-based ultrasound systems are described that utilize the ultrasonic bulk-wave sensing to detect the damages and flaws in the aerospace structures. These systems apply pulse-echo or through transmission methods to detect longitudinal through-the-thickness bulk-waves. These thermoelastic waves are generated using Q-switched laser and non-contact sensing is performed using a laser Doppler vibrometer (LDV). Laser-based raster scanning is performed by either twoaxis translation stage for linear-scanning or galvanometer-based laser mirror scanner for angular-scanning. In all ultrasonic propagation imagers, the ultrasonic data is captured and processed in real-time and the ultrasonic propagation can be visualized during scanning. The scanning speed can go up to 1.8 kHz for two-axis linear translation stage based B-UPIs and 10 kHz for galvanometer-based laser mirror scanners. In contrast with the other available ultrasound systems, these systems have the advantage of high-speed, non-contact, real-time, and non-destructive inspection. In this paper, the description of all bulk-wave ultrasonic imagers (B-UPIs) are presented and their advantages are discussed. Experiments are performed with these system on various structures to proof the integrity of their results. The C-scan results produced from non-dispersive, through-the-thickness, bulk-wave detection show good agreement in detection of structural variances and damage location in all inspected structures. These results show that bulk-wave UPIs can be used for in-situ NDE of engineering structures.
NASA Technical Reports Server (NTRS)
Lovelace, Jeffrey J.; Cios, Krzysztof J.; Roth, Don J.; Cao, Wei
2000-01-01
Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact data. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary wave forms in the time and frequency domains along with the calculation of several frequency dependent properties including Phase Velocity and Attenuation Coefficient and several frequency independent properties, like the Cross Correlation Velocity. The system allows image generation on all of the frequency dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of in-depth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on a SQL database. It is ideal for classification of material properties, or location of microstructure variations in materials.
NASA Technical Reports Server (NTRS)
Cantrell, Sean A.; Cantrell, John H.; Lillehei, Peter T.
2007-01-01
A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. The method employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope engages the sample top surface. The cantilever is driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave at the sample surface generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create amplitude and phase-generated images of nanoscale near-surface and subsurface features. RDF-AFUM phase images of LaRC-CP2 polyimide polymer containing embedded nanostructures are presented. A RDF-AFUM micrograph of a 12.7 micrometer thick film of LaRC-CP2 containing a monolayer of gold nanoparticles embedded 7 micrometers below the specimen surface reveals the occurrence of contiguous amorphous and crystalline phases within the bulk of the polymer and a preferential growth of the crystalline phase in the vicinity of the gold nanoparticles. A RDF-AFUM micrograph of LaRC-CP2 film containing randomly dispersed carbon nanotubes reveals the growth of an interphase region at certain nanotube-polymer interfaces.
Transmission of 100-MHz-range ultrasound through a fused quartz fiber.
Irie, Takasuke; Tagawa, Norio; Tanabe, Masayuki; Moriya, Tadashi; Yoshizawa, Masasumi; Iijima, Takashi; Itoh, Kouichi; Yokoyama, Taku; Kumagai, Hideki; Taniguchi, Nobuyuki
2011-07-01
This paper describes an investigation into direct observation of microscopic images of tissue using a thin acoustic wave guide. First, the characteristics of the ultrasonic wave propagated in a fused quartz fiber were measured using the reflection method in order to study the insertion loss and the frequency shift of the ultrasonic wave transmitted from the transducer. Next, a receiving transducer was placed close to the end of the fiber, and the characteristics of the ultrasonic waves propagated through the acoustic coupling medium were measured using the penetration method in order to study the insertion loss and the frequency-dependent attenuation of the penetrated waves. Finally, a C-mode image was obtained by optimizing the measuring conditions using the results of the above measurements and scanning the ultrasonic beams on a target (coin) in water. A reflected wave with a peak frequency of approximately 220 MHz was obtained from the end of the fiber. The transmitted ultrasonic waves propagated through the acoustic coupling medium were detected with a frequency range of approximately 125-170 MHz, and the maximum detectable distance of the waves was approximately 1.2 mm within the 100-MHz frequency range. Finally, a high-frequency C-mode image of a coin in water was obtained using a tapered fused quartz fiber. The results suggest that it is necessary to improve the signal-to-noise ratio and reduce the insertion loss in the experimental system in order to make it possible to obtain microscopic images of tissue.
Ultrasonic scanning system for imaging flaw growth in composites
NASA Technical Reports Server (NTRS)
Kiraly, L. J.; Meyn, E. H.
1982-01-01
A system for measuring and visually representing damage in composite specimens while they are being loaded was demonstrated. It uses a hobbiest grade microcomputer system to control data taking and image processing. The system scans operator selected regions of the specimen while it is under load in a tensile test machine and measures internal damage by the attenuation of a 2.5 MHz ultrasonic beam passed through the specimen. The microcomputer dynamically controls the position of ultrasonic transducers mounted on a two axis motor driven carriage. As many as 65,536 samples can be taken and filed on a floppy disk system in less than four minutes.
NASA Technical Reports Server (NTRS)
Roberti, Dino; Ludwig, Reinhold; Looft, Fred J.
1988-01-01
A 3-D computer model of a piston radiator with lenses for focusing and defocusing is presented. To achieve high-resolution imaging, the frequency of the transmitted and received ultrasound must be as high as 10 MHz. Current ultrasonic transducers produce an extremely narrow beam at these high frequencies and thus are not appropriate for imaging schemes such as synthetic-aperture focus techniques (SAFT). Consequently, a numerical analysis program has been developed to determine field intensity patterns that are radiated from ultrasonic transducers with lenses. Lens shapes are described and the field intensities are numerically predicted and compared with experimental results.
NASA Astrophysics Data System (ADS)
Bachmann, A.; Krutzlinger, M.; Zaeh, M. F.
2018-06-01
Friction Stir Welding (FSW) is an innovative joining technique, which has proven to produce high quality joints in high strength aluminum alloys. Consequently, it is commonly used to manufacture lightweight aerospace structures with stringent requirements. For these structures, it is necessary to ensure a high ultimate tensile strength (UTS). Various studies have reported that the UTS is significantly influenced by the welding parameters. Samples welded with different parameter sets showed a considerably different UTS, despite being free from detectable welding defects (e.g. tunnel defect, voids, or lack of penetration). Based on the observations in the literature, a hypothesis was posed. The welding temperature along with the welding speed determine the UTS of the weld. This study aims to prove this hypothesis experimentally by using temperature-controlled FSW to join plates of EN AW-2219-T87 in butt joint configuration. The welded samples were examined using visual inspection, metallography, X-ray imaging, and uniaxial tensile tests. Finally, a statistical analysis was conducted. Hereby, the hypothesis was confirmed.
Design of motion adjusting system for space camera based on ultrasonic motor
NASA Astrophysics Data System (ADS)
Xu, Kai; Jin, Guang; Gu, Song; Yan, Yong; Sun, Zhiyuan
2011-08-01
Drift angle is a transverse intersection angle of vector of image motion of the space camera. Adjusting the angle could reduce the influence on image quality. Ultrasonic motor (USM) is a new type of actuator using ultrasonic wave stimulated by piezoelectric ceramics. They have many advantages in comparison with conventional electromagnetic motors. In this paper, some improvement was designed for control system of drift adjusting mechanism. Based on ultrasonic motor T-60 was designed the drift adjusting system, which is composed of the drift adjusting mechanical frame, the ultrasonic motor, the driver of Ultrasonic Motor, the photoelectric encoder and the drift adjusting controller. The TMS320F28335 DSP was adopted as the calculation and control processor, photoelectric encoder was used as sensor of position closed loop system and the voltage driving circuit designed as generator of ultrasonic wave. It was built the mathematic model of drive circuit of the ultrasonic motor T-60 using matlab modules. In order to verify the validity of the drift adjusting system, was introduced the source of the disturbance, and made simulation analysis. It designed the control systems of motor drive for drift adjusting system with the improved PID control. The drift angle adjusting system has such advantages as the small space, simple configuration, high position control precision, fine repeatability, self locking property and low powers. It showed that the system could accomplish the mission of drift angle adjusting excellent.
Population size estimation of female sex workers in Iran: Synthesis of methods and results.
Sharifi, Hamid; Karamouzian, Mohammad; Baneshi, Mohammad Reza; Shokoohi, Mostafa; Haghdoost, AliAkbar; McFarland, Willi; Mirzazadeh, Ali
2017-01-01
Estimating the number of key populations at risk of HIV is essential for planning, monitoring, and evaluating prevention, care, and treatment programmes. We conducted this study to estimate the number of female sex workers (FSW) in major cities of Iran. We used three population size estimation methods (i.e., wisdom of the crowds, multiplier method, and network scale-up) to calculate the number of FSW in 13 cities in Iran. The wisdom of the crowds and multiplier methods were integrated into a nationwide bio-behavioural surveillance survey in 2015, and the network scale-up method was included in a national survey of the general population in 2014. The median of the three methods was used to calculate the proportion of the adult female population who practice sex work in the 13 cities. These figures were then extrapolated to provide a national population size estimation of FSW across urban areas. The population size of FSW was 91,500 (95% Uncertainty Intervals [UIs] 61,400-117,700), corresponding to 1.43% (95% UIs 0.96-1.84) of the adult (i.e., 15-49 year-old) female population living in these 13 cities. The projected numbers of FSW for all 31 provincial capital cities were 130,800 (95% UIs 87,800-168,200) and 228,700 (95% UIs 153,500-294,300) for all urban settings in Iran. Using methods of comparable rigor, our study provided a data-driven national estimate of the population size of FSW in urban areas of Iran. Our findings provide vital information for enhancing HIV programme planning and lay a foundation for assessing the impact of harm reduction efforts within this marginalized population.
Population size estimation of female sex workers in Iran: Synthesis of methods and results
Sharifi, Hamid; Karamouzian, Mohammad; Baneshi, Mohammad Reza; Shokoohi, Mostafa; Haghdoost, AliAkbar; McFarland, Willi
2017-01-01
Introduction Estimating the number of key populations at risk of HIV is essential for planning, monitoring, and evaluating prevention, care, and treatment programmes. We conducted this study to estimate the number of female sex workers (FSW) in major cities of Iran. Methods We used three population size estimation methods (i.e., wisdom of the crowds, multiplier method, and network scale-up) to calculate the number of FSW in 13 cities in Iran. The wisdom of the crowds and multiplier methods were integrated into a nationwide bio-behavioural surveillance survey in 2015, and the network scale-up method was included in a national survey of the general population in 2014. The median of the three methods was used to calculate the proportion of the adult female population who practice sex work in the 13 cities. These figures were then extrapolated to provide a national population size estimation of FSW across urban areas. Results The population size of FSW was 91,500 (95% Uncertainty Intervals [UIs] 61,400–117,700), corresponding to 1.43% (95% UIs 0.96–1.84) of the adult (i.e., 15–49 year-old) female population living in these 13 cities. The projected numbers of FSW for all 31 provincial capital cities were 130,800 (95% UIs 87,800–168,200) and 228,700 (95% UIs 153,500–294,300) for all urban settings in Iran. Conclusions Using methods of comparable rigor, our study provided a data-driven national estimate of the population size of FSW in urban areas of Iran. Our findings provide vital information for enhancing HIV programme planning and lay a foundation for assessing the impact of harm reduction efforts within this marginalized population. PMID:28796847
Couture, Marie-Claude; Page, Kimberly; Sansothy, Neth; Stein, Ellen; Vun, Mean Chhi; Hahn, Judith A
2017-01-01
Background In Cambodia, most of the female sex workers (FSW) work in venues where unhealthy alcohol use is ubiquitous and potentially contributing to the HIV epidemic. However, no accurate data exists. We compare self-reported unhealthy alcohol consumption to a biomarker of alcohol intake in Cambodian FSW and male clients, and determine factors associated with unhealthy alcohol use. Methods A cross-sectional study was conducted among FSW (n=100) and male clients (n=100) in entertainment and sex work venues in Cambodia. Self-reported unhealthy alcohol use (AUDIT-C) was compared to phosphatidylethanol (PEth) positive (≥50ng/ml), a biomarker of alcohol intake. Sociodemographics data was collected. Correlates of self-reported unhealthy alcohol use and PEth positive were determined. Results The prevalence of PEth positive in FSW was 60.0%. Self-reported unhealthy alcohol consumption was reported by 85.0% of the women. Almost all women (95.0%) testing PEth positive also reported unhealthy alcohol use. Prevalence of unhealthy alcohol consumption (self-report and PEth positive) was higher in FSW working in entertainment establishments compared to other sex work venues (p<0.01). Among male clients, 47.0% reported unhealthy alcohol consumption and 42.0% had a PEth positive. However, only 57.1% of male clients with PEth positive reported unhealthy alcohol use. Conclusions Unhealthy alcohol consumption is prevalent in Cambodian sex work settings. Self-reported unhealthy alcohol use is well reported by FSW, but less by male clients. These findings highlight the urgency of using accurate measures of unhealthy alcohol consumption and integrating this health issue into HIV prevention interventions. PMID:27251102
Couture, Marie-Claude; Page, Kimberly; Sansothy, Neth; Stein, Ellen; Vun, Mean Chhi; Hahn, Judith A
2016-08-01
In Cambodia, most of the female sex workers (FSW) work in venues where unhealthy alcohol use is ubiquitous and potentially contributing to the HIV epidemic. However, no accurate data exists. We compare self-reported unhealthy alcohol consumption to a biomarker of alcohol intake in Cambodian FSW and male clients, and determine factors associated with unhealthy alcohol use. A cross-sectional study was conducted among FSW (n=100) and male clients (n=100) in entertainment and sex work venues in Cambodia. Self-reported unhealthy alcohol use (AUDIT-C) was compared to phosphatidylethanol (PEth) positive (≥50ng/ml), a biomarker of alcohol intake. Sociodemographics data was collected. Correlates of self-reported unhealthy alcohol use and PEth positive were determined. The prevalence of PEth positive in FSW was 60.0%. Self-reported unhealthy alcohol consumption was reported by 85.0% of the women. Almost all women (95.0%) testing PEth positive also reported unhealthy alcohol use. Prevalence of unhealthy alcohol consumption (self-report and PEth positive) was higher in FSW working in entertainment establishments compared to other sex work venues (p<0.01). Among male clients, 47.0% reported unhealthy alcohol consumption and 42.0% had a PEth positive. However, only 57.1% of male clients with PEth positive reported unhealthy alcohol use. Unhealthy alcohol consumption is prevalent in Cambodian sex work settings. Self-reported unhealthy alcohol use is well reported by FSW, but less by male clients. These findings highlight the urgency of using accurate measures of unhealthy alcohol consumption and integrating this health issue into HIV prevention interventions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chen, Nadine E; Strathdee, Steffanie A; Rangel, Gudelia; Patterson, Thomas L; Uribe-Salas, Felipe J; Rosen, Perth; Villalobos, Jorge; Brouwer, Kimberly C
2012-12-28
In a study of female sex workers (FSW) servicing truck driver clients in Mexican border cities, we evaluated differences in HIV/STI risk behaviors by workplace. Cross-sectional study of FSW servicing truck drivers in Mexico: 100 from Nuevo Laredo (U.S. border); 100 from Ciudad Hidalgo (Guatemalan border). Main outcome was unstable workplace, defined as primary place of sex work in a public place (street, vehicle, gas station, etc.) vs. stable workplace (bar, brothel, and hotel). Logistic regression was used to identify correlates associated with trading sex at unstable workplaces in the last month. Of the FSW surveyed, 18% reported an unstable workplace. The majority of FSW surveyed were young (<30), single, had <9 th grade education, and had worked in the sex trade for a median of 4.9 years. After controlling for study site, FSW with unstable vs. stable workplaces were more likely to have a majority/all truck driver clientele, but were less likely to have visited a gynecologist in the last year (OR 0.1, 95%CI 0.03-0.4) or ever had an HIV test (OR 0.1, 95%CI 0.06-0.3), and there was a trend towards lower condom use self-efficacy scores (OR 0.8 per unit increase, 95%CI 0.7-1.0). On multivariate regression, unstable workplace was associated with having majority/all truck driver clientele, being surveyed in Nuevo Laredo, and decreased odds of ever having an HIV test. Among Mexican FSW with truck driver clients, providing safe indoor spaces for sex work may help facilitate public health interventions that improve HIV/STI and reproductive health outcomes.
NASA Astrophysics Data System (ADS)
An, Yun-Kyu; Song, Homin; Sohn, Hoon
2014-09-01
This paper presents a wireless ultrasonic wavefield imaging (WUWI) technique for detecting hidden damage inside a steel box girder bridge. The proposed technique allows (1) complete wireless excitation of piezoelectric transducers and noncontact sensing of the corresponding responses using laser beams, (2) autonomous damage visualization without comparing against baseline data previously accumulated from the pristine condition of a target structure and (3) robust damage diagnosis even for real structures with complex structural geometries. First, a new WUWI hardware system was developed by integrating optoelectronic-based signal transmitting and receiving devices and a scanning laser Doppler vibrometer. Next, a damage visualization algorithm, self-referencing f-k filter (SRF), was introduced to isolate and visualize only crack-induced ultrasonic modes from measured ultrasonic wavefield images. Finally, the performance of the proposed technique was validated through hidden crack visualization at a decommissioned Ramp-G Bridge in South Korea. The experimental results reveal that the proposed technique instantaneously detects and successfully visualizes hidden cracks even in the complex structure of a real bridge.
Resonant difference-frequency atomic force ultrasonic microscope
NASA Technical Reports Server (NTRS)
Cantrell, John H. (Inventor); Cantrell, Sean A. (Inventor)
2010-01-01
A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.
Papadacci, Clement; Tanter, Mickael; Pernot, Mathieu; Fink, Mathias
2014-06-01
The assessment of fiber architecture is of major interest in the progression of myocardial disease. Recent techniques such as magnetic resonance diffusion tensor imaging (MR-DTI) or ultrasound elastic tensor imaging (ETI) can derive the fiber directions by measuring the anisotropy of water diffusion or tissue elasticity, but these techniques present severe limitations in a clinical setting. In this study, we propose a new technique, backscatter tensor imaging (BTI), which enables determination of the fiber directions in skeletal muscles and myocardial tissues, by measuring the spatial coherence of ultrasonic speckle. We compare the results to ultrasound ETI. Acquisitions were performed using a linear transducer array connected to an ultrasonic scanner mounted on a motorized rotation device with angles from 0° to 355° by 5° increments to image ex vivo bovine skeletal muscle and porcine left ventricular myocardial samples. At each angle, multiple plane waves were transmitted and the backscattered echoes recorded. The coherence factor was measured as the ratio of coherent intensity over incoherent intensity of backscattered echoes. In skeletal muscle, maximal/minimal coherence factor was found for the probe parallel/perpendicular to the fibers. In myocardium, the coherence was assessed across the entire myocardial thickness, and the position of maxima and minima varied transmurally because of the complex fibers distribution. In ETI, the shear wave speed variation with the probe angle was found to follow the coherence variation. Spatial coherence can thus reveal the anisotropy of the ultrasonic speckle in skeletal muscle and myocardium. BTI could be used on any type of ultrasonic scanner with rotating phased-array probes or 2-D matrix probes for noninvasive evaluation of myocardial fibers.
Papadacci, Clement; Tanter, Mickael; Pernot, Mathieu; Fink, Mathias
2014-01-01
The assessment of fiber architecture is of major interest in the progression of myocardial disease. Recent techniques such as Magnetic Resonance (MR) Diffusion Tensor Imaging or Ultrasound Elastic Tensor Imaging (ETI) can derive the fiber directions by measuring the anisotropy of water diffusion or tissue elasticity, but these techniques present severe limitations in clinical setting. In this study, we propose a new technique, the Backscatter Tensor Imaging (BTI) which enables determining the fibers directions in skeletal muscles and myocardial tissues, by measuring the spatial coherence of ultrasonic speckle. We compare the results to ultrasound ETI. Acquisitions were performed using a linear transducer array connected to an ultrasonic scanner mounted on a motorized rotation device with angles from 0° to 355° by 5° increments to image ex vivo bovine skeletal muscle and porcine left ventricular myocardial samples. At each angle, multiple plane waves were transmitted and the backscattered echoes recorded. The coherence factor was measured as the ratio of coherent intensity over incoherent intensity of backscattered echoes. In skeletal muscle, maximal/minimal coherence factor was found for the probe parallel/perpendicular to the fibers. In myocardium, the coherence was assessed across the entire myocardial thickness, and the position of maxima and minima varied transmurally due to the complex fibers distribution. In ETI, the shear wave speed variation with the probe angle was found to follow the coherence variation. Spatial coherence can thus reveal the anisotropy of the ultrasonic speckle in skeletal muscle and myocardium. BTI could be used on any type of ultrasonic scanner with rotative phased-array probes or 2-D matrix probes for non-invasive evaluation of myocardial fibers. PMID:24859662
Signal detection using support vector machines in the presence of ultrasonic speckle
NASA Astrophysics Data System (ADS)
Kotropoulos, Constantine L.; Pitas, Ioannis
2002-04-01
Support Vector Machines are a general algorithm based on guaranteed risk bounds of statistical learning theory. They have found numerous applications, such as in classification of brain PET images, optical character recognition, object detection, face verification, text categorization and so on. In this paper we propose the use of support vector machines to segment lesions in ultrasound images and we assess thoroughly their lesion detection ability. We demonstrate that trained support vector machines with a Radial Basis Function kernel segment satisfactorily (unseen) ultrasound B-mode images as well as clinical ultrasonic images.
NASA Technical Reports Server (NTRS)
Loftus, Zachary; Arbegast, W. J.; Hartley, P. J.
1998-01-01
Friction Stir Welding (FSW) is a new and innovative solid-state joining process which can be applied to difficult-to- weld aluminum alloys. However, the large forces involved with the process have posed a production tooling challenge. Lockheed Martin Michoud Space Systems has overcome many of these challenges on the Super Lightweight External Tank (ET) program. Utilizing Aluminum-Copper-Lithium alloy 2195 in the form of plate and extrusions, investigations of FSW process parameters have been completed. Major loading mechanisms are discussed in conjunction with deflection measurements. Since the ET program is a cryogenic application, a brief comparison of cryogenic material properties with room temperature material properties is offered for both FSW and fusion welds. Finally, a new approach to controlling the FSW process from a load perspective is introduced. Emphasis will be put on tooling development, as well as the impact of tooling design and philosophy on Friction Stir Weld success probability.
Mirzazadeh, Ali; Haghdoost, Ali Akbar; Nedjat, Saharnaz; Navadeh, Soodabeh; McFarland, Willi; Mohammad, Kazem
2013-02-01
We quantified discrepancies in reported behaviors of female sex workers (FSW) by comparing 63 face-to-face interviews (FTFI) to in-depth interviews (IDI), with corroboration of the directions and magnitudes of reporting by a panel of psychologists who work with FSW. Sensitivities, specificities, positive and negative predictive values (PPV and NPV) were assessed for FTFI responses using IDI as a "gold standard". Sensitivities were lowest in reporting symptoms of sexually transmitted infections (63.9 %), finding sex partners in venues (52.4 %) and not receiving HIV test results (66.7 %). Specificities (all >83 %) and PPVs (all >74.0 %) were higher than NPV. FSW significantly under-reported number of clients, sexual contacts and non-condom use sex acts with clients and number of days engaging in sex work in the preceding week. This study provides a quantified gauge of reporting biases in FSW behaviors. Such estimates and methods help better understand true HIV risk in marginalized populations and calibrate survey estimates accordingly.
Understanding STI Risk and Condom Use Patterns by Partner Type Among Female Sex Workers in Peru.
Kinsler, Janni J; Blas, Magaly M; Cabral, Alejandra; Carcamo, Cesar; Halsey, Neal; Brown, Brandon
2014-01-01
While brothel-based sex work is regulated by the Peruvian government, there is little data on STI risk factors reported by female sex workers (FSW). This study compared high risk behaviors among 120 Peruvian FSW from government regulated brothels with both clients and non-commercial partners. Our study found that 12% of FSW reported unprotected vaginal sex with clients (compared to 75% with non-commercial partners), and 42% reported unprotected anal sex with clients (compared to 87% with non-commercial partners). Group differences were observed in the expectation to have oral sex (32% for partners vs 60% for clients; p<0.01), and a history of anal sex (65% for partners vs 32% for clients; p<0.01) and both vaginal and anal sex with the same partners (46% for partners vs 25% for clients; p<0.001). These findings suggest that FSW constitute an important bridge population for STI/HIV transmission in Peru.
NASA Technical Reports Server (NTRS)
Horton, K. Renee; McGill, Preston; Barkey, Mark
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. This work reports on the microstructure and microhardness of SR-FSW between two dissimilar aluminum alloys. Specifically, the study examines the cross section of the weld joint formed between an AA2014-T6 plate on the advancing side and an AA2219-T87 plate on the retreating side. The microstructural analysis shows an irregularly displaced weld seam from the advancing side past the thermo-mechanical affected zone (TMAZ) into the weld nugget region. There are sharp variations in the microhardness across the weld. These variations are described in the paper and mechanisms for their formation are discussed.
Brown, Jane D.; Muessig, Kathryn E.; Xianxiang, Feng; Wenzhen, He
2013-01-01
We conducted qualitative interviews with 48 female sex workers (FSW) recruited from entertainment venues in Liuzhou, China. Analyses found that HIV knowledge and sexual health seeking strategies differed by size of venue: (1) Women in smaller venues said they douched before/after sex and used condoms with all but their regular partners and clients. Most found the brochures distributed by Chinese CDC workers “irrelevant” or “boring” and relied on friends for health advice. (2) FSW in middle and large venues were less concerned about prevention, claiming their clients were “healthy.” They relied more on the Internet for health information and were less concerned about the cost of seeing a doctor. (3) Pregnancies and abortions were frequent, especially among the younger women in large venues. This research documents the need to develop tailored HIV-related messages and prevention strategies with the help of FSW to address differences among FSW working in venues of different sizes. PMID:23612941
Mantsios, Andrea; Galai, Noya; Mbwambo, Jessie; Likindikoki, Samuel; Shembilu, Catherine; Mwampashi, Ard; Beckham, S W; Leddy, Anna; Davis, Wendy; Sherman, Susan; Kennedy, Caitlin; Kerrigan, Deanna
2018-02-24
This study assessed the association between community savings group participation and consistent condom use (CCU) among female sex workers (FSW) in Iringa, Tanzania. Using cross-sectional data from a survey of venue-based FSW (n = 496), logistic regression was used to examine the associations between financial indicators including community savings group participation and CCU. Over one-third (35%) of the women participated in a savings group. Multivariable regression results indicated that participating in a savings group was significantly associated with nearly two times greater odds of CCU with new clients in the last 30 days (aOR = 1.77, 95% CI 1.10-2.86). Exploratory mediation analysis indicated that the relationship between savings group participation and CCU was partially mediated by financial security, as measured by monthly income. Findings indicate that community savings groups may play an important role in reducing sexual risk behaviors of FSW and hold promise as part of comprehensive, community-led HIV prevention strategies among FSW.
NASA Astrophysics Data System (ADS)
Liu, Fenjun; Fu, Li; Chen, Haiyan
2018-06-01
Sound friction stir welded (FSW) joints of 6061-T6 aluminum alloy sheets with an 0.8 mm thickness were obtained at conventional speed (2000 rpm, 300 mm/min) and high speed (11,000 rpm, 1500 mm/min). The recrystallization mechanism, precipitate evolution, mechanical properties and fracture behavior were investigated in detail. Microstructure analyses revealed that the grain structure evolution in the nugget zone (NZ) was dominated by continuous dynamic recrystallization. In the process of FSW, high speed facilitates the formation of finer equiaxed recrystallized grains, higher density of dislocations and substructures, and a larger number of precipitates in the NZ compared to the conventional speed, which further significantly improves the hardness and tensile strength of the joints. The maximum tensile strength was obtained with 292.6 MPa, 83.2% for the 6061-T6 aluminum alloy and 122.6% for the conventional-speed FSW joints. This work provides an effective method for preparing FSW aluminum alloy thin plate joints with excellent mechanical properties.
Space Shuttle ET Friction Stir Weld Machines
NASA Technical Reports Server (NTRS)
Thompson, Jack M.
2003-01-01
NASA and Lockheed-Martin approached the FSW machine vendor community with a specification for longitudinal barrel production FSW weld machines and a shorter travel process development machine in June of 2000. This specification was based on three years of FSW process development on the Space Shuttle External Tank alloys, AL2 195-T8M4 and AL22 19-T87. The primary motivations for changing the ET longitudinal welds from the existing variable polarity Plasma Arc plasma weld process included: (1) Significantly reduced weld defect rates and related reduction in cycle time and uncertainty; (2) Many fewer process variables to control (5 vs. 17); (3) Fewer manufacturing steps; (4) Lower residual stresses and distortion; (5) Improved weld strengths, particularly at cryogenic temperatures; (6) Fewer hazards to production personnel. General Tool was the successful bidder. The equipment is at this writing installed and welding flight hardware. This paper is a means of sharing with the rest of the FSW community the unique features developed to assure NASA/L-M of successful production welds.
Flexible Friction Stir Joining Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Zhili; Lim, Yong Chae; Mahoney, Murray
2015-07-23
Reported herein is the final report on a U.S. Department of Energy (DOE) Advanced Manufacturing Office (AMO) project with industry cost-share that was jointly carried out by Oak Ridge National Laboratory (ORNL), ExxonMobil Upstream Research Company (ExxonMobil), and MegaStir Technologies (MegaStir). The project was aimed to advance the state of the art of friction stir welding (FSW) technology, a highly energy-efficient solid-state joining process, for field deployable, on-site fabrications of large, complex and thick-sectioned structures of high-performance and high-temperature materials. The technology innovations developed herein attempted to address two fundamental shortcomings of FSW: 1) the inability for on-site welding andmore » 2) the inability to weld thick section steels, both of which have impeded widespread use of FSW in manufacturing. Through this work, major advance has been made toward transforming FSW technology from a “specialty” process to a mainstream materials joining technology to realize its pervasive energy, environmental, and economic benefits across industry.« less
Jing, Bowen; Tang, Shanshan; Wu, Liang; Wang, Supin; Wan, Mingxi
2016-12-01
Ultrafast plane wave ultrasonography is employed in this study to visualize the vibration of the larynx and quantify the vibration phase as well as the vibration amplitude of the laryngeal tissue. Ultrasonic images were obtained at 5000 to 10,000 frames/s in the coronal plane at the level of the glottis. Although the image quality degraded when the imaging mode was switched from conventional ultrasonography to ultrafast plane wave ultrasonography, certain anatomic structures such as the vocal folds, as well as the sub- and supraglottic structures, including the false vocal folds, can be identified in the ultrafast plane wave ultrasonic image. The periodic vibration of the vocal fold edge could be visualized in the recorded image sequence during phonation. Furthermore, a motion estimation method was used to quantify the displacement of laryngeal tissue from hundreds of frames of ultrasonic data acquired. Vibratory displacement waveforms of the sub- and supraglottic structures were successfully obtained at a high level of ultrasonic signal correlation. Moreover, statistically significant differences in vibration pattern between the sub- and supraglottic structures were found. Variation of vibration amplitude along the subglottic mucosal surface is significantly smaller than that along the supraglottic mucosal surface. Phase delay of vibration along the subglottic mucosal surface is significantly smaller than that along the supraglottic mucosal surface. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Cannata, Jonathan M; Ritter, Timothy A; Chen, Wo-Hsing; Silverman, Ronald H; Shung, K Kirk
2003-11-01
This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO3) single-element ultrasonic transducers in the 20-80 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.
Mental Health and Functioning of Female Sex Workers in Chittagong, Bangladesh.
Hengartner, Michael P; Islam, Md Nazrul; Haker, Helene; Rössler, Wulf
2015-01-01
To examine the mental health and functioning of female sex workers (FSW) in Chittagong, Bangladesh, a population that has commonly been neglected in mental health policy and research. We included 259 women in the study (M age: 23.2 years; range: 11-48). The comprehensive Composite International Diagnostic Interview was used to assess their 12-month prevalence rates of DSM-IV mental disorders, and a comprehensive questionnaire was adapted to explore various factors, such as socio-demographics, working and living conditions, or experiences of abuse. On average, participants began their commercial sex work at 18.5 years old (range: 10-45). Their main motives for sex work were coercion (49.4%) and the necessity to financially support families (54.8%). In total, 224 FSW (86.5%) wanted to quit commercial sex work. A mental disorder within the past 12 months was reported by 100 FSW (38.6%), with drug abuse clearly being the most prevalent diagnosis (15.4%). Sexual, physical, and emotional abuse were very common among the FSW, and substance use disorders (SUD) were significantly more prevalent in persons who experienced emotional abuse (OR = 2.2). Prevalence rates of any mental disorder and SUD were higher in women who did sex work to support their family, whereas mood disorders were more frequent in those who needed the money to pay debts. Participants with any disorder were significantly older than those without (M age: 24.4 vs. 22.5 years) and had started significantly later in the sex business (M age: 19.7 vs. 17.7 years). Our study revealed that FSW in Chittagong are very vulnerable and highly impaired, as expressed by high rates of abuse and mental disorders. Coercion is very common and many FSW are required to work in the sex business because they need the money to support their families. FSW are a very marginalized population, especially in the developing countries where awareness for mental health is low and the availability of mental health services is insufficient.
Baral, Stefan; Ketende, Sosthenes; Green, Jessie L; Chen, Ping-An; Grosso, Ashley; Sithole, Bhekie; Ntshangase, Cebisile; Yam, Eileen; Kerrigan, Deanna; Kennedy, Caitlin E; Adams, Darrin
2014-01-01
HIV is hyperendemic in Swaziland with a prevalence of over 25% among those between the ages of 15 and 49 years old. The HIV response in Swaziland has traditionally focused on decreasing HIV acquisition and transmission risks in the general population through interventions such as male circumcision, increasing treatment uptake and adherence, and risk-reduction counseling. There is emerging data from Southern Africa that key populations such as female sex workers (FSW) carry a disproportionate burden of HIV even in generalized epidemics such as Swaziland. The burden of HIV and prevention needs among FSW remains unstudied in Swaziland. A respondent-driven-sampling survey was completed between August-October, 2011 of 328 FSW in Swaziland. Each participant completed a structured survey instrument and biological HIV and syphilis testing according to Swazi Guidelines. Unadjusted HIV prevalence was 70.3% (n = 223/317) among a sample of women predominantly from Swaziland (95.2%, n = 300/316) with a mean age of 21(median 25) which was significantly higher than the general population of women. Approximately one-half of the FSW(53.4%, n = 167/313) had received HIV prevention information related to sex work in the previous year, and about one-in-ten had been part of a previous research project(n = 38/313). Rape was common with nearly 40% (n = 123/314) reporting at least one rape; 17.4% (n = 23/314)reported being raped 6 or more times. Reporting blackmail (34.8%, n = 113/314) and torture(53.2%, n = 173/314) was prevalent. While Swaziland has a highly generalized HIV epidemic, reconceptualizing the needs of key populations such as FSW suggests that these women represent a distinct population with specific vulnerabilities and a high burden of HIV compared to other women. These women are understudied and underserved resulting in a limited characterization of their HIV prevention, treatment, and care needs and only sparse specific and competent programming. FSW are an important population for further investigation and rapid scale-up of combination HIV prevention including biomedical, behavioral, and structural interventions.
Facile nanofibrillation of chitin derivatives by gas bubbling and ultrasonic treatments in water.
Tanaka, Kohei; Yamamoto, Kazuya; Kadokawa, Jun-ichi
2014-10-29
In this paper, we report that nanofiber network structures were constructed from chitin derivatives by gas bubbling and ultrasonic treatments in water. When chitin was first subjected to N2 gas bubbling with ultrasonication in water, the SEM images of the product showed nanofiber network morphology. However, nanofiber network was not re-constructed by the same N2 gas bubbling and ultrasonic treatments after agglomeration. We then have paid attention to an amidine group to provide the agglomeration-nanofibrillation behavior of chitin derivatives. An amidinated chitin was synthesized by the reaction of the amino groups in a partially deacetylated chitin with N,N-dimethylacetamide dimethyl acetal, which was subjected to CO2 gas bubbling and ultrasonic treatments in water to convert into an amidinium chitin by protonation. The SEM images of the product clearly showed nanofiber network morphology. We further examined re-nanofibrillation of the agglomerated material, which was obtained by mixing the nanofibrillated amidinium chitin with water, followed by drying under reduced pressure. Consequently, the material was re-nanofibrillated by N2 gas bubbling with ultrasonication in water owing to electrostatic repulsion between the amidinium groups. Furthermore, deprotonation of the amidinium chitin and re-protonation of the resulting amidinated chitin were conducted by alkaline treatment and CO2 gas bubbling-ultrasonic treatments, respectively. The material showed the agglomeration-nanofibrillation behavior during the processes. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Miller, James G.
1997-01-01
In this Progress Report, we describe our recent developments of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns for a thin woven composite in an immersion setup. In addition, we compare apparent signal loss measurements of the thin woven composite for phase-sensitive and phase-insensitive detection methods. All images of diffraction patterns have been included on the accompanying CD-ROM in the Adobe(Trademark) Portable Document Format (PDF). Due to the extensive amount of data, however, hardcopies of only a small representative selection of the images are included within the printed report. This Progress Report presents experimental results that support successful implementation of single element as well as one and two-dimensional ultrasonic array technologies for the inspection of textile composite structures. In our previous reports, we have addressed issues regarding beam profiles of ultrasonic pressure fields transmitted through a water reference path and transmitted through a thin woven composite sample path. Furthermore, we presented experimental results of the effect of a thin woven composite on the magnitude of an insonifying ultrasonic pressure field. In addition to the study of ultrasonic beam profiles, we consider issues relevant to the application of single-element, one-dimensional, and two-dimensional array technologies towards probing the mechanical properties of advanced engineering composites and structures. We provide comparisons between phase-sensitive and phase-insensitive detection methods for determination of textile composite structure parameters. We also compare phase-sensitive and phase-insensitive - - ---- ----- apparent signal loss measurements in an effort to study the phenomenon of phase cancellation at the face of a finite-aperture single-element receiver. Furthermore, in this Progress Report we extend our work on ultrasonic beam profile issues through investigation of the phase fronts of the pressure field. In Section H of this Progress Report we briefly describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. Section III details the analysis of the experimental data followed by the experimental results in Section IV. Finally, a discussion of the observations and conclusions is found in Section V.
Gang, Tingting; Hu, Manli; Rong, Qiangzhou; Qiao, Xueguang; Liang, Lei; Liu, Nan; Tong, Rongxin; Liu, Xiaobo; Bian, Ce
2016-12-14
A micro-fiber-optic Fabry-Perot interferometer (FPI) is proposed and demonstrated experimentally for ultrasonic imaging of seismic physical models. The device consists of a micro-bubble followed by the end of a single-mode fiber (SMF). The micro-structure is formed by the discharging operation on a short segment of hollow-core fiber (HCF) that is spliced to the SMF. This micro FPI is sensitive to ultrasonic waves (UWs), especially to the high-frequency (up to 10 MHz) UW, thanks to its ultra-thin cavity wall and micro-diameter. A side-band filter technology is employed for the UW interrogation, and then the high signal-to-noise ratio (SNR) UW signal is achieved. Eventually the sensor is used for lateral imaging of the physical model by scanning UW detection and two-dimensional signal reconstruction.
Monitoring of freeze-thaw cycles in concrete using embedded sensors and ultrasonic imaging.
Ranz, Javier; Aparicio, Sofía; Romero, Héctor; Casati, María Jesús; Molero, Miguel; González, Margarita
2014-01-29
This paper deals with the study of damage produced during freeze-thaw (F-T) cycles using two non-destructive measurement approaches-the first approach devoted to continuous monitoring using embedded sensors during the cycles, and the second one, performing ultrasonic imaging before and after the cycles. Both methodologies have been tested in two different types of concrete specimens, with and without air-entraining agents. Using the first measurement approach, the size and distribution of pores were estimated using a thermoporometrical model and continuous measurements of temperature and ultrasonic velocity along cycles. These estimates have been compared with the results obtained using mercury porosimetry testing. In the second approach, the damage due to F-T cycles has been evaluated by automated ultrasonic transmission and pulse-echo inspections made before and after the cycles. With these inspections the variations in the dimensions, velocity and attenuation caused by the accelerated F-T cycles were determined.
Design of an ultrasonic micro-array for near field sensing during retinal microsurgery.
Clarke, Clyde; Etienne-Cummings, Ralph
2006-01-01
A method for obtaining the optimal and specific sensor parameters for a tool-tip mountable ultrasonic transducer micro-array is presented. The ultrasonic transducer array sensor parameters, such as frequency of operation, element size, inter-element spacing, number of elements and transducer geometry are obtained using a quadratic programming method to obtain a maximum directivity while being constrained to a total array size of 4 mm2 and the required resolution for retinal imaging. The technique is used to design a uniformly spaced NxN transducer array that is capable of resolving structures in the retina that are as small as 2 microm from a distance of 100 microm. The resultant 37x37 array of 16 microm transducers with 26 microm spacing will be realized as a Capacitive Micromachined Ultrasonic Transducer (CMUT) array and used for imaging and robotic guidance during retinal microsurgery.
A Novel Application of Ultrasonic Imaging to Study Smoldering Combustion
NASA Technical Reports Server (NTRS)
Tse, S. D.; Anthenien, R. A.; Fernandez-Pello, A. Carlos; Miyasaka, K.
1997-01-01
An ultrasonic imaging technique has been developed to examine the propagation of a smolder reaction within a porous combustible material. The technique provides information about the location of a propagating smolder front, as well as line-of-sight average permeability variations of the smoldering material. The method utilizes the observation that transmission of an ultrasonic signal through a porous material increases with permeability. Since a propagating smolder reaction leaves behind char with a higher permeability than the original material, ultrasound transmission can be employed to monitor smolder progress. The technique can also be used to track the char evolution as it continues to react. Experiments are presented where the technique is applied to smoldering combustion in a two-dimensional geometry. The results have furthered the understanding of two-dimensional smolder, especially in identifying the controlling mechanisms leading to the transition from smoldering to flaming. The applicability of ultrasonic tomography to smoldering combustion has also been investigated.
NASA Astrophysics Data System (ADS)
Bilgunde, Prathamesh N.; Bond, Leonard J.
2018-04-01
Ultrasonic imaging is a key enabling technology required for in-service inspection of advanced sodium fast reactors at the hot stand-by operating mode (˜250C). Current work presents development of a single element, 2.4MHz, planar, ultrasonic immersion transducer for a potential application in ranging, inspection and imaging of the reactor components. The prototype immersion transducer is first tested in water for three thermal cycles up to 92C. The transducer is further evaluated for four thermal cycles in silicone oil, with total seven thermal cycles that exceeded operation period of 21 hours. Moreover, the preliminary data acquired for speed of sound in silicone oil indicates 24% reduction from 22C to 142C. Sensitivity of the ultrasonic transducer is also measured as a function of temperature and demonstrates the effect of multiple thermal cycles on the transducer components.
Monitoring of Freeze-Thaw Cycles in Concrete Using Embedded Sensors and Ultrasonic Imaging
Ranz, Javier; Aparicio, Sofía; Romero, Héctor; Casati, María Jesús; Molero, Miguel; González, Margarita
2014-01-01
This paper deals with the study of damage produced during freeze-thaw (F-T) cycles using two non-destructive measurement approaches—the first approach devoted to continuous monitoring using embedded sensors during the cycles, and the second one, performing ultrasonic imaging before and after the cycles. Both methodologies have been tested in two different types of concrete specimens, with and without air-entraining agents. Using the first measurement approach, the size and distribution of pores were estimated using a thermoporometrical model and continuous measurements of temperature and ultrasonic velocity along cycles. These estimates have been compared with the results obtained using mercury porosimetry testing. In the second approach, the damage due to F-T cycles has been evaluated by automated ultrasonic transmission and pulse-echo inspections made before and after the cycles. With these inspections the variations in the dimensions, velocity and attenuation caused by the accelerated F-T cycles were determined. PMID:24481231
NASA Technical Reports Server (NTRS)
Roth, D. J.; Cosgriff, L. M.; Martin, R. E.; Verrilli, M. J.; Bhatt, R. T.
2003-01-01
In this study, an ultrasonic guided wave scan system was used to characterize various microstructural and flaw conditions in two types of ceramic matrix composites, SiC/SiC and C/SiC. Rather than attempting to isolate specific lamb wave modes to use for characterization (as is desired for many types of guided wave inspection problems), the guided wave scan system utilizes the total (multi-mode) ultrasonic response in its inspection analysis. Several time and frequency-domain parameters are calculated from the ultrasonic guided wave signal at each scan location to form images. Microstructural and defect conditions examined include delamination, density variation, cracking, and pre/ post-infiltration. Results are compared with thermographic imaging methods. Although the guided wave technique is commonly used so scanning can be eliminated, applying the technique in the scanning mode allows a more precise characterization of defect conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoelzer, David T.; Bunn, Jeffrey R.; Gussev, Maxim N.
The development of friction stir welding (FSW) for joining thin sections of the advanced oxide dispersion strengthened (ODS) 14YWT ferritic alloy was initiated in Fuel Cycle Research and Development (FCRD), now the Nuclear Technology Research and Development (NTRD), in 2015. The first FSW experiment was conducted in late FY15 and successfully produced a bead-on-plate stir zone (SZ) on a 1 mm thick plate of 14YWT (SM13 heat). The goal of this research task is to ultimately demonstrate that FSW is a feasible method for joining thin wall (0.5 mm thick) tubing of 14YWT.
Friction Stir Welding (FSW) of Aged CuCrZr Alloy Plates
NASA Astrophysics Data System (ADS)
Jha, Kaushal; Kumar, Santosh; Nachiket, K.; Bhanumurthy, K.; Dey, G. K.
2018-01-01
Friction Stir Welding (FSW) of Cu-0.80Cr-0.10Zr (in wt pct) alloy under aged condition was performed to study the effects of process parameters on microstructure and properties of the joint. FSW was performed over a wide range of process parameters, like tool-rotation speed (from 800 to 1200 rpm) and tool-travel speed (from 40 to 100 mm/min), and the resulting thermal cycles were recorded on both sides (advancing and retreating) of the joint. The joints were characterized for their microstructure and tensile properties. The welding process resulted in a sound and defect-free weld joint, over the entire range of the process parameters used in this study. Microstructure of the stir zone showed fine and equiaxed grains, the scale of which varied with FSW process parameters. Grain size in the stir zone showed direct correlation with tool rotation and inverse correlation with tool-travel speed. Tensile strength of the weld joints was ranging from 225 to 260 MPa, which is substantially lower than that of the parent metal under aged condition ( 400 MPa), but superior to that of the parent material under annealed condition ( 220 MPa). Lower strength of the FSW joint than that of the parent material under aged condition can be attributed to dissolution of the precipitates in the stir zone and TMAZ. These results are presented and discussed in this paper.
NASA Astrophysics Data System (ADS)
Kamal Babu, K.; Panneerselvam, K.; Sathiya, P.; Noorul Haq, A.; Sundarrajan, S.; Mastanaiah, P.; Srinivasa Murthy, C. V.
The purpose of this paper is to present the corrosion behavior of the Cryorolled (CR) material and its Friction Stir Welded joints. Due to the thermal cycles of Friction Stir Welding (FSW) process, the corrosion behavior of the material gets affected. Here, the cryorolling process was carried out on AA2219 alloy and CR material was joined by FSW process using four different pin tool profiles such as cylindrical, threaded cylindrical, square and hexagonal pin. The FSW joints were analyzed by corrosion resistance with the help of potentiodynamic polarization test with 3.5% NaCl solution. From the analysis, it is found that CR AA2219 material exhibits good corrosion resistance compared to the base AA2219 material, and also a hexagonal pin profile FSW joint exhibits high corrosion resistance. Among the weld joints created by four different tools, the lowest corrosion resistance was found in the cylindrical pin tool FSW welds. Further, the corroded samples were investigated through metallurgical investigations like OM, Transmission Electron Microscopy (TEM), Energy-Dispersive X-ray Spectroscopy (EDX) and X-Ray Diffraction (XRD). It was found that the amount of dissolution of Al2Cu precipitate was present in the weld nugget. The amount of dissolution of Al2Cu precipitate is higher in the weld nugget produced by hexagonal pin tool. This is due to the enhancement of the corrosion resistance.
NASA Technical Reports Server (NTRS)
Roth, Don J.
1998-01-01
NASA Lewis Research Center's Life Prediction Branch, in partnership with Sonix, Inc., and Cleveland State University, recently advanced the development of, refined, and commercialized an advanced nondestructive evaluation (NDE) inspection method entitled the Single Transducer Thickness-Independent Ultrasonic Imaging Method. Selected by R&D Magazine as one of the 100 most technologically significant new products of 1996, the method uses a single transducer to eliminate the superimposing effects of thickness variation in the ultrasonic images of materials. As a result, any variation seen in the image is due solely to microstructural variation. This nondestructive method precisely and accurately characterizes material gradients (pore fraction, density, or chemical) that affect the uniformity of a material's physical performance (mechanical, thermal, or electrical). Advantages of the method over conventional ultrasonic imaging include (1) elimination of machining costs (for precision thickness control) during the quality control stages of material processing and development and (2) elimination of labor costs and subjectivity involved in further image processing and image interpretation. At NASA Lewis, the method has been used primarily for accurate inspections of high temperature structural materials including monolithic ceramics, metal matrix composites, and polymer matrix composites. Data were published this year for platelike samples, and current research is focusing on applying the method to tubular components. The initial publicity regarding the development of the method generated 150 requests for further information from a wide variety of institutions and individuals including the Federal Bureau of Investigation (FBI), Lockheed Martin Corporation, Rockwell International, Hewlett Packard Company, and Procter & Gamble Company. In addition, NASA has been solicited by the 3M Company and Allison Abrasives to use this method to inspect composite materials that are manufactured by these companies.
Deep sub-wavelength ultrasonic imaging
NASA Astrophysics Data System (ADS)
Amireddy, Kiran Kumar; Balasubramaniam, Krishnan; Rajagopal, Prabhu
2018-04-01
There is much interest in improving the resolution of ultrasonic inspection, which suffers from large wavelengths typically in the range of millimeters, due to low value of speed of sound in solid media. The authors are interested in achieving this through holey structured metamaterial lenses, and have recently demonstrated an experimental subwavelength resolution of λ/25. However the previous work was in through-transmission mode with reception using Laser Doppler Vibrometer (LDV), which may not be suitable for practical applications. This paper discusses the use of optimized holey structured metalens to achieve a deep sub-wavelength imaging up to λ/18 in through-transmission mode, but using commercially available piezoelectric ultrasonic transducers for both generation and reception of ultrasound.
NASA Technical Reports Server (NTRS)
Cao, Wei; Roth, Don J.
1997-01-01
This article presents the description of PSIDD(2), a post-scan interactive data display system for ultrasonic contact scan and single measurement analysis. PSIDD(2) was developed in conjunction with ASTM standards for ultrasonic velocity and attenuation coefficient contact measurements. This system has been upgraded from its original version PSIDD(1) and improvements are described in this article. PSIDD(2) implements a comparison mode where the display of time domain waveforms and ultrasonic properties versus frequency can be shown for up to five scan points on one plot. This allows the rapid contrasting of sample areas exhibiting different ultrasonic properties as initially indicated by the ultrasonic contact scan image. This improvement plus additional features to be described in the article greatly facilitate material microstructural appraisal.
Detection of fastener loosening in simple lap joint based on ultrasonic wavefield imaging
NASA Astrophysics Data System (ADS)
Gooda Sahib, M. I.; Leong, S. J.; Chia, C. C.; Mustapha, F.
2017-12-01
Joints in aero-mechanical structures are critical elements that ensure the structural integrity but they are prone to damages. Inspection of such joints that have no prior baseline data is really challenging but it can be possibly done using the Ultrasonic Propagation Imager (UPI). The feasibility of applying UPI for detection of loosened fastener is investigated in this study. A simple lap joint specimen made by connecting two pieces of 2.5mm thick SAE304 stainless steel plates using five M6 screws and nuts has been used in this study. All fasteners are tightened to 10Nm but one of them is completely loosened to simulate the damage. The wavefield data is processed into ultrasonic wavefield propagation video and a series of spectral amplitude images. The spectral images showed noticeable amplitude difference at the loosened fastener, hence confirmed the feasibility of using UPI for structural joints inspection. A simple contrast maximization method is also introduced to improve the result.
Yoshizawa, Shin; Matsuura, Keiko; Takagi, Ryo; Yamamoto, Mariko; Umemura, Shin-Ichiro
2016-01-01
A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.
29 CFR 1910.427 - Liveboating.
Code of Federal Regulations, 2010 CFR
2010-07-01
... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Commercial Diving Operations Specific Operations Procedures § 1910.427... of 220 fsw; (3) Using mixed gas at depths greater than 220 fsw; (4) In rough seas which significantly... while a diver is in the water. (5) A diver-carried reserve breathing gas supply shall be carried by each...
Dong, Biqin; Li, Hao; Zhang, Zhen; Zhang, Kevin; Chen, Siyu; Sun, Cheng; Zhang, Hao F
2015-01-01
Photoacoustic microscopy (PAM) is an attractive imaging tool complementary to established optical microscopic modalities by providing additional molecular specificities through imaging optical absorption contrast. While the development of optical resolution photoacoustic microscopy (ORPAM) offers high lateral resolution, the acoustically-determined axial resolution is limited due to the constraint in ultrasonic detection bandwidth. ORPAM with isometric spatial resolution along both axial and lateral direction is yet to be developed. Although recently developed sophisticated optical illumination and reconstruction methods offer improved axial resolution in ORPAM, the image acquisition procedures are rather complicated, limiting their capabilities for high-speed imaging and being easily integrated with established optical microscopic modalities. Here we report an isometric ORPAM based on an optically transparent micro-ring resonator ultrasonic detector and a commercial inverted microscope platform. Owing to the superior spatial resolution and the ease of integrating our ORPAM with established microscopic modalities, single cell imaging with extrinsic fluorescence staining, intrinsic autofluorescence, and optical absorption can be achieved simultaneously. This technique holds promise to greatly improve the accessibility of PAM to the broader biomedical researchers.
Coded excitation ultrasonic needle tracking: An in vivo study.
Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E
2016-07-01
Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.
NASA Technical Reports Server (NTRS)
Goldfine, Neil; Grundy, David; Zilberstein, Vladimir; Kinchen, David G.; McCool, Alex (Technical Monitor)
2002-01-01
Friction Stir Welds (FSW) of Al 2195-T8 and Al 2219-T8, provided by Lockheed Martin Michoud Operations, were inspected for lack-of-penetration (LOP) defects using a custom designed MWM-Array, a multi-element eddy-current sensor. MWM (registered trademark) electrical conductivity mapping demonstrated high sensitivity to LOP as small as 0.75 mm (0.03 in.), as confirmed by metallographic data that characterized the extent of LOP defects. High sensitivity and high spatial resolution was achieved via a 37-element custom designed MWM-Array allowing LOP detection using the normalized longitudinal component of the MWM measured conductivity. This permitted both LOP detection and correlation of MWM conductivity features with the LOP defect size, as changes in conductivity were apparently associated with metallurgical features within the near-surface layer of the LOP defect zone. MWM conductivity mapping reveals information similar to macro-etching as the MWM-Array is sensitive to small changes in conductivity due to changes in microstructure associated with material thermal processing, in this case welding. The electrical conductivity measured on the root side of FSWs varies across the weld due to microstructural differences introduced by the FSW process, as well as those caused by planar flaws. Weld metal, i.e., dynamically recrystallized zone (DXZ), thermomechanically affected zone (TMZ), heat-affected zone (HAZ), and parent metal (PM) are all evident in the conductivity maps. While prior efforts had met with limited success for NDE (Nondestructive Evaluation) of dissimilar alloy, Al2219 to Al2195 FSW, the new custom designed multi-element MWM-Array achieved detection of all LOP defects even in dissimilar metal welds.
NASA Technical Reports Server (NTRS)
1978-01-01
A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.
Forward ultrasonic model validation using wavefield imaging methods
NASA Astrophysics Data System (ADS)
Blackshire, James L.
2018-04-01
The validation of forward ultrasonic wave propagation models in a complex titanium polycrystalline material system is accomplished using wavefield imaging methods. An innovative measurement approach is described that permits the visualization and quantitative evaluation of bulk elastic wave propagation and scattering behaviors in the titanium material for a typical focused immersion ultrasound measurement process. Results are provided for the determination and direct comparison of the ultrasonic beam's focal properties, mode-converted shear wave position and angle, and scattering and reflection from millimeter-sized microtexture regions (MTRs) within the titanium material. The approach and results are important with respect to understanding the root-cause backscatter signal responses generated in aerospace engine materials, where model-assisted methods are being used to understand the probabilistic nature of the backscatter signal content. Wavefield imaging methods are shown to be an effective means for corroborating and validating important forward model predictions in a direct manner using time- and spatially-resolved displacement field amplitude measurements.
NASA Astrophysics Data System (ADS)
Wang, Lihong V.
Photoacoustic tomography (PAT) refers to imaging that is based on the photoacoustic effect. Although the photoacoustic effect as a physical phenomenon was first reported on by Alexander Graham Bell in 1880 [1], PAT as an imaging technology was developed only after the advent of ultrasonic transducers, computers, and lasers [2-31]. A review on biomedical photoacoustics is available [32]. The motivation for PAT is to combine optical-absorption contrast with ultrasonic spatial resolution for deep imaging in the optical quasi-diffusive or diffusive regime. In PAT, the tissue is irradiated by usually a short-pulsed laser beam to achieve a thermal and acoustic impulse response (Fig. 19.1). Locally absorbed light is converted into heat, which is further converted to a pressure rise via thermo-elastic expansion. The initial pressure rise - determined by the local optical absorption coefficient (μ â ), fluence (ψ) and other thermal and mechanical properties - propagates as an ultrasonic wave, which is referred to as a photoacoustic wave.
Defect Inspection of Flip Chip Solder Bumps Using an Ultrasonic Transducer
Su, Lei; Shi, Tielin; Xu, Zhensong; Lu, Xiangning; Liao, Guanglan
2013-01-01
Surface mount technology has spurred a rapid decrease in the size of electronic packages, where solder bump inspection of surface mount packages is crucial in the electronics manufacturing industry. In this study we demonstrate the feasibility of using a 230 MHz ultrasonic transducer for nondestructive flip chip testing. The reflected time domain signal was captured when the transducer scanning the flip chip, and the image of the flip chip was generated by scanning acoustic microscopy. Normalized cross-correlation was used to locate the center of solder bumps for segmenting the flip chip image. Then five features were extracted from the signals and images. The support vector machine was adopted to process the five features for classification and recognition. The results show the feasibility of this approach with high recognition rate, proving that defect inspection of flip chip solder bumps using the ultrasonic transducer has high potential in microelectronics packaging.
An Efficient Image Recovery Algorithm for Diffraction Tomography Systems
NASA Technical Reports Server (NTRS)
Jin, Michael Y.
1993-01-01
A diffraction tomography system has potential application in ultrasonic medical imaging area. It is capable of achieving imagery with the ultimate resolution of one quarter the wavelength by collecting ultrasonic backscattering data from a circular array of sensors and reconstructing the object reflectivity using a digital image recovery algorithm performed by a computer. One advantage of such a system is that is allows a relatively lower frequency wave to penetrate more deeply into the object and still achieve imagery with a reasonable resolution. An efficient image recovery algorithm for the diffraction tomography system was originally developed for processing a wide beam spaceborne SAR data...
NASA Astrophysics Data System (ADS)
Konovalenko S., Iv.; Psakhie, S. G.
2017-12-01
Using the molecular dynamics method, we simulated the atomic scale butt friction stir welding on two crystallites and varied the onset FSW tool plunge depth. The effects of the plunge depth value on the thermomechanical evolution of nanosized crystallites and mass transfer in the course of FSW have been studied. The increase of plunge depth values resulted in more intense heating and reducing the plasticized metal resistance to the tool movement. The mass transfer intensity was hardly dependent on the plunge depth value. The plunge depth was recommended to be used as a FSW process control parameter in addition to the commonly used ones.
Effect of Weld Tool Geometry on Friction Stir Welded AA2219-T87 Properties
NASA Technical Reports Server (NTRS)
Querin, Joseph A.; Schneider, Judy A.
2008-01-01
In this study, flat panels of AA2219-T87 were friction stir welded (FSWed) using weld tools with tapered pins The three pin geometries of the weld tools included: 0 (straight cylinder), 30 , and 60 angles on the frustum. For each weld tool geometry, the FSW process parameters were optimized to eliminate defects. A constant heat input was maintained while varying the process parameters of spindle rpm and travel speed. This provided a constant heat input for each FSW weld panel while altering the hot working conditions imparted to the workpiece. The resulting mechanical properties were evaluated from tensile test results of the FSW joint.
NASA Astrophysics Data System (ADS)
Lu, Y.; Tang, H.; Fung, S.; Wang, Q.; Tsai, J. M.; Daneman, M.; Boser, B. E.; Horsley, D. A.
2015-06-01
This paper presents an ultrasonic fingerprint sensor based on a 24 × 8 array of 22 MHz piezoelectric micromachined ultrasonic transducers (PMUTs) with 100 μm pitch, fully integrated with 180 nm complementary metal oxide semiconductor (CMOS) circuitry through eutectic wafer bonding. Each PMUT is directly bonded to a dedicated CMOS receive amplifier, minimizing electrical parasitics and eliminating the need for through-silicon vias. The array frequency response and vibration mode-shape were characterized using laser Doppler vibrometry and verified via finite element method simulation. The array's acoustic output was measured using a hydrophone to be ˜14 kPa with a 28 V input, in reasonable agreement with predication from analytical calculation. Pulse-echo imaging of a 1D steel grating is demonstrated using electronic scanning of a 20 × 8 sub-array, resulting in 300 mV maximum received amplitude and 5:1 contrast ratio. Because the small size of this array limits the maximum image size, mechanical scanning was used to image a 2D polydimethylsiloxane fingerprint phantom (10 mm × 8 mm) at a 1.2 mm distance from the array.
Campanelli, Sabina Luisa; Casalino, Giuseppe; Casavola, Caterina; Moramarco, Vincenzo
2013-01-01
Friction Stir Welding (FSW) is a solid-state joining process; i.e., no melting occurs. The welding process is promoted by the rotation and translation of an axis-symmetric non-consumable tool along the weld centerline. Thus, the FSW process is performed at much lower temperatures than conventional fusion welding, nevertheless it has some disadvantages. Laser Assisted Friction Stir Welding (LAFSW) is a combination in which the FSW is the dominant welding process and the laser pre-heats the weld. In this work FSW and LAFSW tests were conducted on 6 mm thick 5754H111 aluminum alloy plates in butt joint configuration. LAFSW is studied firstly to demonstrate the weldability of aluminum alloy using that technique. Secondly, process parameters, such as laser power and temperature gradient are investigated in order to evaluate changes in microstructure, micro-hardness, residual stress, and tensile properties. Once the possibility to achieve sound weld using LAFSW is demonstrated, it will be possible to explore the benefits for tool wear, higher welding speeds, and lower clamping force. PMID:28788430
Conners, Erin E.; Silverman, Jay G.; Ulibarri, Monica; Magis-Rodriguez, Carlos; Strathdee, Steffanie A.; Staines-Orozco, Hugo; Patterson, Thomas L.; Brouwer, Kimberly C.
2015-01-01
Female sex workers (FSW) are disproportionately affected by both HIV and gender-based violence, such as that perpetrated by clients (CPV). We used a structural determinants framework to assess correlates of physical or sexual CPV in the past 6 months among FSW in the Mexico/U.S. border cities of Ciudad Juárez and Tijuana. Bivariate and multivariate logistic regression analysis identified individual, client, interpersonal, work environment and macrostructural factors associated with recent CPV. Among 496 FSW, 5% experienced recent CPV. Witnessing violence towards other FSW in one's neighborhood (aOR:5.6, 95% CI:1.8-17.2), having a majority of foreign (aOR:3.5, 95% CI:1.4-8.4) or substance using (aOR:4.0, 95% CI:1.5-10.4) clients, and being a street worker (aOR:3.0, 95% CI:1.1-7.7) were independently associated with recent CPV. Our findings underscore the vulnerability of FSWs and the need to design policies and interventions addressing macro-level influences on CPV rather than exclusively targeting individual behaviors. PMID:26111732
NASA Astrophysics Data System (ADS)
Liu, X. P.; Lin Peng, R.; Hofmann, M.; Johansson, S.; Wang, Y. D.
2011-01-01
An in-situ neutron diffraction technique was used to investigate the lattice strain distributions and micromechanical behavior in a friction stir welded (FSW) sheet of AA7475-T761. The neutron diffraction experiments were performed on the spectrometer for material research, STRESS-SPEC, at FRM II (Garching, Germany). The lattice strain profiles around the weld center were measured as a function of the applied strain during the tensile loading and unloading. The anisotropic elastic and plastic properties of the FSW aluminum alloy were simulated by elasto-plastic self-consistent (EPSC) model to predict the anisotropic deformation behaviors involving the grain-to-grain interactions. Material parameters used for describing the constitutive laws of each test position were determined from the measured lattice strain distributions for different diffraction hkl planes as well as the macroscopic stress-strain curve of the FSW aluminum alloy. A good agreement between experimental results and numerical simulations was obtained. The present investigations provided a reliable prediction of the anisotropic micromechanical behavior of the FSW aluminum alloy during tensile deformation.
Calibration of 3D ALE finite element model from experiments on friction stir welding of lap joints
NASA Astrophysics Data System (ADS)
Fourment, Lionel; Gastebois, Sabrina; Dubourg, Laurent
2016-10-01
In order to support the design of such a complex process like Friction Stir Welding (FSW) for the aeronautic industry, numerical simulation software requires (1) developing an efficient and accurate Finite Element (F.E.) formulation that allows predicting welding defects, (2) properly modeling the thermo-mechanical complexity of the FSW process and (3) calibrating the F.E. model from accurate measurements from FSW experiments. This work uses a parallel ALE formulation developed in the Forge® F.E. code to model the different possible defects (flashes and worm holes), while pin and shoulder threads are modeled by a new friction law at the tool / material interface. FSW experiments require using a complex tool with scroll on shoulder, which is instrumented for providing sensitive thermal data close to the joint. Calibration of unknown material thermal coefficients, constitutive equations parameters and friction model from measured forces, torques and temperatures is carried out using two F.E. models, Eulerian and ALE, to reach a satisfactory agreement assessed by the proper sensitivity of the simulation to process parameters.
NASA Technical Reports Server (NTRS)
Li, Zhixian; Arbegast, William J.; Meletis, Efstathios I.
1997-01-01
Friction stir welding process is being evaluated for application on the Al-Cu-Li 2195 Super-Light Weight External Tank of the Space Transportation System. In the present investigation Al-Cu-Li 2195 plates were joined by autogenous friction stir welding (FSW) and hybrid FSW (friction stir welding over existing variable polarity plasma arc weld). Optical microscopy and transmission electron microscopy (TEM) were utilized to characterize microstructures of the weldments processed by both welding methods. TEM observations of autogenous FSW coupons in the center section of the dynamically-recrystallized zone showed an equiaxed recrystallized microstructure with an average grain size of approx. 3.8 microns. No T(sub 1), precipitates were present in the above-mentioned zone. Instead, T(sub B) and alpha precipitates were found in this zone with a lower population. Alternate immersion, anodic polarization, constant load, and slow strain tests were carried out to evaluate the general corrosion and stress-corrosion properties of autogenous and hybrid FSW prepared coupons. The experimental results will be discussed.
Campanelli, Sabina Luisa; Casalino, Giuseppe; Casavola, Caterina; Moramarco, Vincenzo
2013-12-18
Friction Stir Welding (FSW) is a solid-state joining process; i.e. , no melting occurs. The welding process is promoted by the rotation and translation of an axis-symmetric non-consumable tool along the weld centerline. Thus, the FSW process is performed at much lower temperatures than conventional fusion welding, nevertheless it has some disadvantages. Laser Assisted Friction Stir Welding (LAFSW) is a combination in which the FSW is the dominant welding process and the laser pre-heats the weld. In this work FSW and LAFSW tests were conducted on 6 mm thick 5754H111 aluminum alloy plates in butt joint configuration. LAFSW is studied firstly to demonstrate the weldability of aluminum alloy using that technique. Secondly, process parameters, such as laser power and temperature gradient are investigated in order to evaluate changes in microstructure, micro-hardness, residual stress, and tensile properties. Once the possibility to achieve sound weld using LAFSW is demonstrated, it will be possible to explore the benefits for tool wear, higher welding speeds, and lower clamping force.
NASA Astrophysics Data System (ADS)
Zettler, R.; Blanco, A. C.; dos Santos, J. F.; Marya, S.
An increase in the use of magnesium (Mg) in the car manufacturing industry has raised questions concerning its weldability. Friction Stir Welding (FSW) has the advantage of achieving metallic bonding below that of the melting point of the base material thus avoiding many of the metallurgical problems associated with the solidification process. The present study presents the results of a development program carried out to investigate the response of Mg alloys AZ31 and AZ61 to different FSW tool geometries and process parameters. Temperature development across the weld zone was monitored and the produced welds have been subjected to microstructural analysis and mechanical testing. Defect free welds have been produced with optimised FSW-tool and parameters. The micro structure of the welded joint resulted in similar ductility and hardness levels as compared to that of the base material. The results also demonstrated that tool geometry plays a fundamental role in the response of the investigated alloys to the FSW process.
NASA Astrophysics Data System (ADS)
Gang, Tingting; Hu, Manli; Qiao, Xueguang; Li, JiaCheng; Shao, Zhihua; Tong, Rongxin; Rong, Qiangzhou
2017-01-01
A fiber-optic interferometer is proposed and demonstrated experimentally for ultrasonic detection. The sensor consists of a compact Michelson interferometer (MI), which is fixed in a tilted-tube end-face (45°). Thin gold films are used for the reflective coatings of two arms and one of the interference arms is etched serving as the sensing arm. The spectral sideband filter technique is used to interrogate the continuous and pulse ultrasonic signals (with frequency of 300 KHz). Furthermore, because of the asymmetrical structure of the sensor, it presents strong direction-dependent ultrasonic sensitivity, such that the sensor can be considered a vector detector. The experimental results show that the sensor is highly sensitive to ultrasonic signals, and thus it can be a candidate for ultrasonic imaging of seismic physical models.
NASA Astrophysics Data System (ADS)
Liang, Zhiyuan; Chen, Ke; Wang, Xiaona; Yao, Junshan; Yang, Qi; Zhang, Lanting; Shan, Aidang
2013-08-01
Friction stir welding (FSW) is a promising solid-state joining technique for producing effective welds between Al alloy and Mg alloy. However, previously reported Al/Mg dissimilar FSW joints generally have limited strength or barely any ductility with relatively high strength, which was blamed on the brittle intermetallics formed during welding. In this study, effective joints with comparably high strength (163 MPa) and large elongation (~6 pct) were obtained. Three crucial/weak zones were identified in the welds: (1) Al/Mg bottom interface (BI) zone that resulted from the insufficient materials' intermixing and interdiffusion; (2) banded structure (BS) zone which contains intermetallic particles possibly formed by constitutional liquation; and (3) softened Al alloy to the retreating side (SAA-RS) zone due to the dissolution and coarsening of the strengthening precipitates. Three fracture modes observed in the tensile specimens perpendicular to the weld seam were found closely related to these zones. Their microstructure evolution with the change of tool rotational speed and tool offset was characterized and the consequent effect on the fracture mode alteration was studied. It turned out that enhancing the strengths of all these zones, but keeping the strength of the SAA lowest, is an effective way for enhancing ductility while keeping comparatively high strength in Al/Mg FSW joints. Also, suggestions for further improving the mechanical property of the Al/Mg dissimilar FSW joints were made accordingly for practical applications.
Manopaiboon, C; Prybylski, D; Subhachaturas, W; Tanpradech, S; Suksripanich, O; Siangphoe, U; Johnston, L G; Akarasewi, P; Anand, A; Fox, K K; Whitehead, S J
2013-01-01
The pattern of sex work in Thailand has shifted substantially over the last two decades from direct commercial establishments to indirect venues and non-venue-based settings. This respondent-driven sampling survey was conducted in Bangkok in 2007 among female sex workers (FSW) in non-venue-based settings to pilot a new approach to surveillance among this hidden population. Fifteen initial participants recruited 707 consenting participants who completed a behavioural questionnaire, and provided oral fluid for HIV testing, and urine for sexually transmitted infection (STI) testing. Overall HIV prevalence was 20.2% (95% confidence interval [CI] 16.3-24.7). Three-quarters of women were street-based (75.8%, 95% CI 69.9-81.1) who had an especially high HIV prevalence (22.7%, 95% CI 18.2-28.4); about 10 times higher than that found in routine sentinel surveillance among venue-based FSW (2.5%). STI prevalence (Chlamydia trachomatis and Neisseria gonorrhoeae) was 8.7% (95% CI 6.4-10.8) and 1.0% (95% CI 0.2-1.9), respectively. Lower price per sex act and a current STI infection were independently associated with HIV infection (P < 0.05). High HIV prevalence found among FSW participating in the survey, particularly non-venue-based FSW, identifies need for further prevention efforts. In addition, it identifies a higher-risk segment of FSW not reached through routine sentinel surveillance but accessible through this survey method.
Tiong, T Joyce; Chandesa, Tissa; Yap, Yeow Hong
2017-05-01
One common method to determine the existence of cavitational activity in power ultrasonics systems is by capturing images of sonoluminescence (SL) or sonochemiluminescence (SCL) in a dark environment. Conventionally, the light emitted from SL or SCL was detected based on the number of photons. Though this method is effective, it could not identify the sonochemical zones of an ultrasonic systems. SL/SCL images, on the other hand, enable identification of 'active' sonochemical zones. However, these images often provide just qualitative data as the harvesting of light intensity data from the images is tedious and require high resolution images. In this work, we propose a new image analysis technique using pseudo-colouring images to quantify the SCL zones based on the intensities of the SCL images and followed by comparison of the active SCL zones with COMSOL simulated acoustic pressure zones. Copyright © 2016 Elsevier B.V. All rights reserved.
Ultrasonically Encoded Photoacoustic Flowgraphy in Biological Tissue
NASA Astrophysics Data System (ADS)
Wang, Lidai; Xia, Jun; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-11-01
Blood flow speed is an important functional parameter. Doppler ultrasound flowmetry lacks sufficient sensitivity to slow blood flow (several to tens of millimeters per second) in deep tissue. To address this challenge, we developed ultrasonically encoded photoacoustic flowgraphy combining ultrasonic thermal tagging with photoacoustic imaging. Focused ultrasound generates a confined heat source in acoustically absorptive fluid. Thermal waves propagate with the flow and are directly visualized in pseudo color using photoacoustic computed tomography. The Doppler shift is employed to calculate the flow speed. This method requires only acoustic and optical absorption, and thus is applicable to continuous fluid. A blood flow speed as low as 0.24mm·s-1 was successfully measured. Deep blood flow imaging was experimentally demonstrated under 5-mm-thick chicken breast tissue.
Lyons, Carrie E; Grosso, Ashley; Drame, Fatou M; Ketende, Sosthenes; Diouf, Daouda; Ba, Ibrahima; Shannon, Kate; Ezouatchi, Rebecca; Bamba, Amara; Kouame, Abo; Baral, Stefan
2017-05-01
Violence is a human rights violation, and an important measure in understanding HIV among female sex workers (FSW). However, limited data exist regarding correlates of violence among FSW in Côte d'Ivoire. Characterizing prevalence and determinants of violence and the relationship with structural risks for HIV can inform development and implementation of comprehensive HIV prevention and treatment programs. FSW > 18 years were recruited through respondent driven sampling (RDS) in Abidjan, Côte d'Ivoire. In total, 466 participants completed a socio-behavioral questionnaire and HIV testing. Prevalence estimates of violence were calculated using crude and RDS-adjusted estimates. Relationships between structural risk factors and violence were analyzed using χ tests and multivariable logistic regression. The prevalence of physical violence was 53.6% (250/466), and sexual violence was 43.2% (201/465) among FSW in this study. Police refusal of protection was associated with physical (adjusted Odds Ratio [aOR]: 2.8; 95% confidence interval [CI]: 1.7 to 4.4) and sexual violence (aOR: 3.0; 95% CI: 1.9 to 4.8). Blackmail was associated with physical (aOR: 2.5; 95% CI: 1.5 to 4.2) and sexual violence (aOR: 2.4; 95% CI: 1.5 to 4.0). Physical violence was associated with fear (aOR: 2.2; 95% CI: 1.3 to 3.1) and avoidance of seeking health services (aOR: 2.3; 95% CI: 1.5 to 3.8). Violence is prevalent among FSW in Abidjan and associated with features of the work environment and access to care. These relationships highlight layers of rights violations affecting FSW, underscoring the need for structural interventions and policy reforms to improve work environments, and to address police harassment, stigma, and rights violations to reduce violence and improve access to HIV interventions.
Zhang, Tiejun; Yang, Ying; Yu, Feng; Zhao, Yanping; Lin, Feifei; Minhas, Veenu; Wood, Charles; He, Na
2014-02-05
Limited information on epidemiologic patterns of KSHV, with none focusing on heterosexual transmission, is available in mainland China. To clarify this, a cross-sectional study was conducted among a group of female sex workers (FSW) and general population women (GW) in Shanghai, China. An anonymous questionnaire interview was administrated among 600 FSW and 600 GW. Blood samples were collected and tested for antibodies to KSHV, HSV-2, HIV, syphilis and HBsAg. Correlates of KSHV and HSV-2 were examined using multiple logistic regression analysis. None of the study participants were tested positive for HIV. The seroprevalence of KSHV, HSV-2 , HBV and syphilis was 10.0%, 52.2%, 12.3% and 10.5%, respectively for FSW, and was 11.0%, 15.3%, 9.8% and 2.8%, respectively for GW. KSHV seropositivity was not associated with syphilis and HSV-2 infection as well as sexual practices among either FSW or GW. Nevertheless, HSV-2 infection among FSW was independently associated with being ever married (OR = 1.59; 95%CI: 1.04-2.45), >5 years of prostitution (OR = 2.06; 95%CI: 1.16-3.68) and being syphilis positive (OR = 2.65; 95%CI: 1.43-4.93). HSV-2 infection among GW was independently associated with an age of >35 years (OR = 2.29; 95%CI: 1.07-4.93), having had more than 2 sex partners in the prior 12 months (OR = 6.44; 95%CI: 1.67-24.93) and being syphilis positive (OR = 3.94; 95%CI: 1.38-11.23). A gradual increase of prevalence with the prostitution time group was also detected for HSV-2 and syphilis, but not for KSHV. KSHV is moderately and equivalently prevalent among FSW and GW. Heterosexual contact is not a predominant route for KSHV transmission among Chinese women.
Lyons, Carrie E; Ketende, Sosthenes; Diouf, Daouda; Drame, Fatou M; Liestman, Benjamin; Coly, Karleen; Ndour, Cheikh; Turpin, Gnilane; Mboup, Souleymane; Diop, Karim; Toure-Kane, Coumba; Castor, Delivette; Leye-Diouf, Nafissatou; Baral, Stefan
2017-01-01
Men who have sex with men (MSM) and female sex workers (FSW) are consistently shown to have a higher burden of HIV compared with other adults in Senegal. This study, HIV Prevention 2.0, evaluates the impact of the 3-tiered integrated stigma mitigation interventions (ISMIs) approach to optimizing HIV service delivery for key populations in Senegal. Baseline assessment includes a questionnaire and biological testing for HIV. A proportion of participants enrolled into a 24-month longitudinal cohort with questionnaires and biological testing every 3 months. In these preliminary analyses, ISMIs are evaluated from participants in the cohort through uptake of HIV services and implementation outcomes. Overall, 724 MSM and 758 FSW participated in the baseline assessment. HIV prevalence is 30.2% (n = 219/724) among MSM and 5.3% (n = 40/758) among FSW. Fear of seeking health services among MSM is 17.7% (n = 128/724) at baseline, 10.5% (n = 18/172) at month 3, and 9.8% (n = 10/102) at month 6 (P < 0.004); and among FSW is 21.9% (n = 166/758) at baseline, 8.1% (n = 15/185) at month 3, and 10.7% (n = 18/168) at month 6 (P < 0.001). Overall, 63.9% (n = 62/97) of MSM and 82.5% (n = 118/143) of FSW agreed that the intervention is effective in addressing stigma; however, loss to follow-up was 41.1% among MSM and 10% among FSW. Baseline data reinforce the need for stigma mitigation interventions, combined with enhanced linkage and retention to optimize HIV treatment. Preliminary results show high levels of HIV-related risk determinants and suggest the potential utility of the ISMI to decrease perceived stigma relating to engagement in HIV prevention, treatment, and care services among key populations in Senegal.
Traore, Isidore T; Meda, Nicolas; Hema, Noelie M; Ouedraogo, Djeneba; Some, Felicien; Some, Roselyne; Niessougou, Josiane; Sanon, Anselme; Konate, Issouf; Van De Perre, Philippe; Mayaud, Philippe; Nagot, Nicolas
2015-01-01
Although interventions to control HIV among high-risk groups such as female sex workers (FSW) are highly recommended in Africa, the contents and efficacy of these interventions are unclear. We therefore designed a comprehensive dedicated intervention targeting young FSW and assessed its impact on HIV incidence in Burkina Faso. Between September 2009 and September 2011 we conducted a prospective, interventional cohort study of FSW aged 18 to 25 years in Ouagadougou, with quarterly follow-up for a maximum of 21 months. The intervention combined prevention and care within the same setting, consisting of peer-led education sessions, psychological support, sexually transmitted infections and HIV care, general routine health care and reproductive health services. At each visit, behavioural characteristics were collected and HIV, HSV-2 and pregnancy were tested. We compared the cohort HIV incidence with a modelled expected incidence in the study population in the absence of intervention, using data collected at the same time from FSW clients. The 321 HIV-uninfected FSW enrolled in the cohort completed 409 person-years of follow-up. No participant seroconverted for HIV during the study (0/409 person-years), whereas the expected modelled number of HIV infections were 5.05/409 person-years (95% CI, 5.01-5.08) or 1.23 infections per 100 person-years (p=0.005). This null incidence was related to a reduction in the number of regular partners and regular clients, and by an increase in consistent condom use with casual clients (adjusted odds ratio (aOR)=2.19; 95% CI, 1.16-4.14, p=0.01) and with regular clients (aOR=2.18; 95% CI, 1.26-3.76, p=0.005). Combining peer-based prevention and care within the same setting markedly reduced the HIV incidence among young FSW in Burkina Faso, through reduced risky behaviours.
Wen, Yanting; Xiang, Guishuang; Liang, Xiaoqiu; Tong, Xiaoqian
2018-02-01
The present study is planned to discuss the clinical value of prenatal 3D ultra-sonic diagnosis on fetus hemivertebra deformity through the retrospective analysis of clinical data of fetus hemivertebra deformity. Selected 9 fetus hemivertebra deformity cases, which have been admitted to our hospital during the period from January, 2010 to January, 2016 as study samples, and analyzed their 2D and 3D ultrasonic examination data. 4 cases of the fetus hemivertebra deformity occurred at lumbar vertebra, 3 cases at thoracic vertebra, and 2 cases at thoracolumbar vertebra. There were scoliosis and opened spine bifida (OSB). In 7 cases, there was absence of ribs in fetus. The 2D ultrasonic image showed that: The echo at the center of fetus vertebral arch lesion was blurred or lost. The coronal section showed the deformity of the spine. There was obvious loss of the ossification center. From the cross section, we could see that the vertebral body of the fetus was shrinking and the edges were relatively blurred. The 3D ultrasonic image showed that: the echo at the ossification center of the fetus vertebra was relatively blurred, or even lost. The image also indicated scoliosis deformity of the spine. The vertebral body lesion could be accurately located. 9 cases of fetus hemivertebra deformity have been detected through examination. Labor inductions have been carried out after getting the permission from the family members. The X-ray examination of the fetus after labor induction showed that the diagnosis was correct. Prenatal ultra-sonic examination holds strong potential for the diagnosis of fetus hemivertebra deformity quite early and deserves further clinical evaluation with large sample size.
Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solodov, Igor; Busse, Gerd
2007-12-17
It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.
NASA Technical Reports Server (NTRS)
McComas, David; Stark, Michael; Leake, Stephen; White, Michael; Morisio, Maurizio; Travassos, Guilherme H.; Powers, Edward I. (Technical Monitor)
2000-01-01
The NASA Goddard Space Flight Center Flight Software Branch (FSB) is developing a Guidance, Navigation, and Control (GNC) Flight Software (FSW) product line. The demand for increasingly more complex flight software in less time while maintaining the same level of quality has motivated us to look for better FSW development strategies. The GNC FSW product line has been planned to address the core GNC FSW functionality very similar on many recent low/near Earth missions in the last ten years. Unfortunately these missions have not accomplished significant drops in development cost since a systematic approach towards reuse has not been adopted. In addition, new demands are continually being placed upon the FSW which means the FSB must become more adept at providing GNC FSW functionality's core so it can accommodate additional requirements. These domain features together with engineering concepts are influencing the specification, description and evaluation of FSW product line. Domain engineering is the foundation for emerging product line software development approaches. A product line is 'A family of products designed to take advantage of their common aspects and predicted variabilities'. In our product line approach, domain engineering includes the engineering activities needed to produce reusable artifacts for a domain. Application engineering refers to developing an application in the domain starting from reusable artifacts. The focus of this paper is regarding the software process, lessons learned and on how the GNC FSW product line manages variability. Existing domain engineering approaches do not enforce any specific notation for domain analysis or commonality and variability analysis. Usually, natural language text is the preferred tool. The advantage is the flexibility and adapt ability of natural language. However, one has to be ready to accept also its well-known drawbacks, such as ambiguity, inconsistency, and contradictions. While most domain analysis approaches are functionally oriented, the idea of applying the object-oriented approach in domain analysis is not new. Some authors propose to use UML as the notation underlying domain analysis. Our work is based on the same idea of merging UML and domain analysis. Further, we propose a few extensions to UML in order to express variability, and we define precisely their semantics so that a tool can support them. The extensions are designed to be implemented on the API of a popular industrial CASE tool, with obvious advantages in cost and availability of tool support. The paper outlines the product line processes and identifies where variability must be addressed. Then it describes the product line products with respect to how they accommodate variability. The Celestial Body subdomain is used as a working example. Our results to date are summarized and plans for the future are described.
Thermomechanical conditions and stresses on the friction stir welding tool
NASA Astrophysics Data System (ADS)
Atthipalli, Gowtam
Friction stir welding has been commercially used as a joining process for aluminum and other soft materials. However, the use of this process in joining of hard alloys is still developing primarily because of the lack of cost effective, long lasting tools. Here I have developed numerical models to understand the thermo mechanical conditions experienced by the FSW tool and to improve its reusability. A heat transfer and visco-plastic flow model is used to calculate the torque, and traverse force on the tool during FSW. The computed values of torque and traverse force are validated using the experimental results for FSW of AA7075, AA2524, AA6061 and Ti-6Al-4V alloys. The computed torque components are used to determine the optimum tool shoulder diameter based on the maximum use of torque and maximum grip of the tool on the plasticized workpiece material. The estimation of the optimum tool shoulder diameter for FSW of AA6061 and AA7075 was verified with experimental results. The computed values of traverse force and torque are used to calculate the maximum shear stress on the tool pin to determine the load bearing ability of the tool pin. The load bearing ability calculations are used to explain the failure of H13 steel tool during welding of AA7075 and commercially pure tungsten during welding of L80 steel. Artificial neural network (ANN) models are developed to predict the important FSW output parameters as function of selected input parameters. These ANN consider tool shoulder radius, pin radius, pin length, welding velocity, tool rotational speed and axial pressure as input parameters. The total torque, sliding torque, sticking torque, peak temperature, traverse force, maximum shear stress and bending stress are considered as the output for ANN models. These output parameters are selected since they define the thermomechanical conditions around the tool during FSW. The developed ANN models are used to understand the effect of various input parameters on the total torque and traverse force during FSW of AA7075 and 1018 mild steel. The ANN models are also used to determine tool safety factor for wide range of input parameters. A numerical model is developed to calculate the strain and strain rates along the streamlines during FSW. The strain and strain rate values are calculated for FSW of AA2524. Three simplified models are also developed for quick estimation of output parameters such as material velocity field, torque and peak temperature. The material velocity fields are computed by adopting an analytical method of calculating velocities for flow of non-compressible fluid between two discs where one is rotating and other is stationary. The peak temperature is estimated based on a non-dimensional correlation with dimensionless heat input. The dimensionless heat input is computed using known welding parameters and material properties. The torque is computed using an analytical function based on shear strength of the workpiece material. These simplified models are shown to be able to predict these output parameters successfully.
Interfacial Dynamics of Condensing Vapor Bubbles in an Ultrasonic Acoustic Field
NASA Astrophysics Data System (ADS)
Boziuk, Thomas; Smith, Marc; Glezer, Ari
2016-11-01
Enhancement of vapor condensation in quiescent subcooled liquid using ultrasonic actuation is investigated experimentally. The vapor bubbles are formed by direct injection from a pressurized steam reservoir through nozzles of varying characteristic diameters, and are advected within an acoustic field of programmable intensity. While kHz-range acoustic actuation typically couples to capillary instability of the vapor-liquid interface, ultrasonic (MHz-range) actuation leads to the formation of a liquid spout that penetrates into the vapor bubble and significantly increases its surface area and therefore condensation rate. Focusing of the ultrasonic beam along the spout leads to ejection of small-scale droplets from that are propelled towards the vapor liquid interface and result in localized acceleration of the condensation. High-speed video of Schlieren images is used to investigate the effects of the ultrasonic actuation on the thermal boundary layer on the liquid side of the vapor-liquid interface and its effect on the condensation rate, and the liquid motion during condensation is investigated using high-magnification PIV measurements. High-speed image processing is used to assess the effect of the actuation on the dynamics and temporal variation in characteristic scale (and condensation rate) of the vapor bubbles.
Li, Xiang; Jin, Qiaofeng; Chen, Tan; Zhang, Baoyue; Zheng, Rongqin; Wang, Zhanhui; Zheng, Hairong
2009-01-01
Using ultrasonic contrast microbubbles as acoustic biomarkers and drug carrier vehicles by conjugating tumor specific antibody to microbubbles has shown great potential in ultrasonic tumor molecular imaging or drug-delivery and therapy. Microbubble probe targeting efficiency is one of the major challenges. In this study, we developed a novel method to evaluate the targeting capability and efficiency of microbubbles to cells, and more specifically, microbubbles binding LyP-1 (a cyclic nonapeptide acid peptide) target to cancer cell within a microfluidic system. The micro cell sieves within the microfludic channels could trap the tumor cells and enhance the microbubble's interaction with the cell. Assisted with the controllable fluid shear stress, the microbubble's targeting to the cell and the corresponding affinity efficiency could be quantitatively evaluated under a florescent microscope. The system provides a useful low-cost high efficient in vitro platform for studying microbubble-cell interaction for ultrasonic tumor molecular imaging or drug-delivery and therapy.
Detection of bondline delaminations in multilayer structures with lossy components
NASA Technical Reports Server (NTRS)
Madaras, Eric I.; Winfree, William P.; Smith, B. T.; Heyman, Joseph H.
1988-01-01
The detection of bondline delaminations in multilayer structures using ultrasonic reflection techniques is a generic problem in adhesively bonded composite structures such as the Space Shuttles's Solid Rocket Motors (SRM). Standard pulse echo ultrasonic techniques do not perform well for a composite resonator composed of a resonant layer combined with attenuating layers. Excessive ringing in the resonant layer tends to mask internal echoes emanating from the attenuating layers. The SRM is made up of a resonant steel layer backed by layers of adhesive, rubber, liner and fuel, which are ultrasonically attenuating. The structure's response is modeled as a lossy ultrasonic transmission line. The model predicts that the acoustic response of the system is sensitive to delaminations at the interior bondlines in a few narrow frequency bands. These predictions are verified by measurements on a fabricated system. Successful imaging of internal delaminations is sensitive to proper selection of the interrogating frequency. Images of fabricated bondline delaminations are presented based on these studies.
Photoacoustic tomography of foreign bodies in soft biological tissue.
Cai, Xin; Kim, Chulhong; Pramanik, Manojit; Wang, Lihong V
2011-04-01
In detecting small foreign bodies in soft biological tissue, ultrasound imaging suffers from poor sensitivity (52.6%) and specificity (47.2%). Hence, alternative imaging methods are needed. Photoacoustic (PA) imaging takes advantage of strong optical absorption contrast and high ultrasonic resolution. A PA imaging system is employed to detect foreign bodies in biological tissues. To achieve deep penetration, we use near-infrared light ranging from 750 to 800 nm and a 5-MHz spherically focused ultrasonic transducer. PA images were obtained from various targets including glass, wood, cloth, plastic, and metal embedded more than 1 cm deep in chicken tissue. The locations and sizes of the targets from the PA images agreed well with those of the actual samples. Spectroscopic PA imaging was also performed on the objects. These results suggest that PA imaging can potentially be a useful intraoperative imaging tool to identify foreign bodies.
Design of signal reception and processing system of embedded ultrasonic endoscope
NASA Astrophysics Data System (ADS)
Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin
2009-11-01
Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.
Student Financial Aid Handbook, 2000-2001. Volume 6: Federal Work-Study.
ERIC Educational Resources Information Center
Department of Education, Washington, DC. Student Financial Assistance.
The Federal Work-Study (FWS) Program encourages the part-time employment of undergraduate and graduate students who need the income to help pay the cost of their education and encourages FSW recipients to participate in community service activities. This volume describes the ways schools are required to use money from their FSW Program funds to…
NASA Astrophysics Data System (ADS)
Mondal, Mounarik; Das, Hrishikesh; Ahn, Eun Yeong; Hong, Sung Tae; Kim, Moon-Jo; Han, Heung Nam; Pal, Tapan Kumar
2017-09-01
Friction stir welding (FSW) of dissimilar stainless steels, low nickel austenitic stainless steel and 409M ferritic stainless steel, is experimentally investigated. Process responses during FSW and the microstructures of the resultant dissimilar joints are evaluated. Material flow in the stir zone is investigated in detail by elemental mapping. Elemental mapping of the dissimilar joints clearly indicates that the material flow pattern during FSW depends on the process parameter combination. Dynamic recrystallization and recovery are also observed in the dissimilar joints. Among the two different stainless steels selected in the present study, the ferritic stainless steels shows more severe dynamic recrystallization, resulting in a very fine microstructure, probably due to the higher stacking fault energy.
Laser Peening Effects on Friction Stir Welding
NASA Technical Reports Server (NTRS)
Hatamleh, Omar
2011-01-01
Friction Stir Welding (FSW) is a welding technique that uses frictional heating combined with forging pressure to produce high strength bonds. It is attractive for aerospace applications. Although residual stresses in FSW are generally lower when compared to conventional fusion welds, recent work has shown that significant tensile residual stresses can be present in the weld after fabrication. Therefore, laser shock peening was investigated as a means of moderating the tensile residual stresses produced during welding. This slide presentation reviews the effect of Laser Peening on the weld, in tensile strength, strain, surface roughness, microhardness, surface wear/friction, and fatigue crack growth rates. The study concluded that the laser peening process can result in considerable improvement to crack initiaion, propagation and mechanical properties in FSW.
Sparse signal representation and its applications in ultrasonic NDE.
Zhang, Guang-Ming; Zhang, Cheng-Zhong; Harvey, David M
2012-03-01
Many sparse signal representation (SSR) algorithms have been developed in the past decade. The advantages of SSR such as compact representations and super resolution lead to the state of the art performance of SSR for processing ultrasonic non-destructive evaluation (NDE) signals. Choosing a suitable SSR algorithm and designing an appropriate overcomplete dictionary is a key for success. After a brief review of sparse signal representation methods and the design of overcomplete dictionaries, this paper addresses the recent accomplishments of SSR for processing ultrasonic NDE signals. The advantages and limitations of SSR algorithms and various overcomplete dictionaries widely-used in ultrasonic NDE applications are explored in depth. Their performance improvement compared to conventional signal processing methods in many applications such as ultrasonic flaw detection and noise suppression, echo separation and echo estimation, and ultrasonic imaging is investigated. The challenging issues met in practical ultrasonic NDE applications for example the design of a good dictionary are discussed. Representative experimental results are presented for demonstration. Copyright © 2011 Elsevier B.V. All rights reserved.
Application of laser ultrasonic method for on-line monitoring of friction stir spot welding process.
Zhang, Kuanshuang; Zhou, Zhenggan; Zhou, Jianghua
2015-09-01
Application of a laser ultrasonic method is developed for on-line monitoring of the friction stir spot welding (FSSW) process. Based on the technology of FSSW, laser-generated ultrasonic waves in a good weld and nonweld area are simulated by a finite element method. The reflected and transmitted waves are analyzed to disclose the properties of the welded interface. The noncontact-laser ultrasonic-inspection system was established to verify the numerical results. The reflected waves in the good-weld and nonweld area can be distinguished by time-of-flight. The transmitted waves evidently attenuate in the nonweld area in contrast to signal amplitude in the good weld area because of interfacial impedance difference. Laser ultrasonic C-scan images can sufficiently evaluate the intrinsic character of the weld area in comparison with traditional water-immersion ultrasonic testing results. The research results confirm that laser ultrasonics would be an effective method to realize the characterization of FSSW defects.
NASA Astrophysics Data System (ADS)
Weifeng, Xie; Chenglei, Fan; Chunli, Yang; Sanbao, Lin
2018-02-01
Ultrasonic-wave-assisted gas metal arc welding (U-GMAW) is a new, advanced arc welding method that uses an ultrasonic wave emitted from an ultrasonic radiator above the arc. However, it remains unclear how the ultrasonic wave affects the metal droplet, hindering further application of U-GMAW. In this paper, an improved U-GMAW system was used and its superiority was experimentally demonstrated. Then a series of experiments were designed and performed to study how the ultrasonic wave affects droplet transfer, including droplet size, velocity, and motion trajectory. The behavior of droplet transfer was observed in high-speed images. The droplet transfer is closely related to the distribution of the acoustic field, determined by the ultrasonic current. Moreover, by analyzing the variably accelerated motion of the droplet, the acoustic control of the droplet transfer was intuitively demonstrated. Finally, U-GMAW was successfully used in vertical-up and overhead welding experiments, showing that U-GMAW is promising for use in welding in all positions.
Airborne ultrasonic inspection in carbon/carbon composite materials
NASA Astrophysics Data System (ADS)
Yang, In-Young; Kim, Young-Hun; Park, Je-Woong; Hsu, David K.; Song, Song-Jin; Cho, Hyun-Jun; Kim, Sun-Kyu; Im, Kwang-Hee
2007-07-01
In this work, a carbon/carbon (C/C) composite material was nondestructively characterized with non-contact ultrasonic methods using automated acquisition scanner as well as contact ultrasonic measurement because (C/C) composite materials have obvious high price over conventional materials. Because of permeation of coupling medium such as water, it is desirable to perform contact-less nondestructive evaluation to assess material properties and part homogeneity. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. Especially ultrasonic images and velocities for C/C composite disk brake was measured and found to be consistent to some degree with the non-contact and contact ultrasonic measurement methods. Low frequency through-transmission scans based on both amplitude and time-of-flight of the ultrasonic pulse were used for mapping out the material property inhomogeneity. Measured results were compared with those obtained by the motorized system with using dry-coupling ultrasonics and through transmission method in immersion. Finally, results using a proposed peak-delay measurement method well corresponded to ultrasonic velocities of the pulse overlap method.
Sensitivity images for multi-view ultrasonic array inspection
NASA Astrophysics Data System (ADS)
Budyn, Nicolas; Bevan, Rhodri; Croxford, Anthony J.; Zhang, Jie; Wilcox, Paul D.; Kashubin, Artem; Cawley, Peter
2018-04-01
The multi-view total focusing method (TFM) is an imaging technique for ultrasonic full matrix array data that typically exploits ray paths with zero, one or two internal reflections in the inspected object and for all combinations of longitudinal and transverse modes. The fusion of this vast quantity of views is expected to increase the reliability of ultrasonic inspection; however, it is not trivial to determine which views and which areas are the most suited for the detection of a given type and orientation of defect. This work introduces sensitivity images that give the expected response of a defect in any part of the inspected object and for any view. These images are based on a ray-based analytical forward model. They can be used to determine which views and which areas lead to the highest probability of detection of the defect. They can also be used for quantitatively analyzing the effects of the parameters of the inspection (probe angle and position, for example) on the overall probability of detection. Finally, they can be used to rescale TFM images so that the different views have comparable amplitudes. This methodology is applied to experimental data and discussed.
Broadband Ultrasonic Transducers
NASA Technical Reports Server (NTRS)
Heyser, R. C.
1986-01-01
New geometry spreads out resonance region of piezoelectric crystal. In new transducer, crystal surfaces made nonparallel. One surface planar; other, concave. Geometry designed to produce nearly uniform response over a predetermined band of frequencies and to attenuate strongly frequencies outside band. Greater bandwidth improves accuracy of sonar and ultrasonic imaging equipment.
Ultrasonic image analysis and image-guided interventions.
Noble, J Alison; Navab, Nassir; Becher, H
2011-08-06
The fields of medical image analysis and computer-aided interventions deal with reducing the large volume of digital images (X-ray, computed tomography, magnetic resonance imaging (MRI), positron emission tomography and ultrasound (US)) to more meaningful clinical information using software algorithms. US is a core imaging modality employed in these areas, both in its own right and used in conjunction with the other imaging modalities. It is receiving increased interest owing to the recent introduction of three-dimensional US, significant improvements in US image quality, and better understanding of how to design algorithms which exploit the unique strengths and properties of this real-time imaging modality. This article reviews the current state of art in US image analysis and its application in image-guided interventions. The article concludes by giving a perspective from clinical cardiology which is one of the most advanced areas of clinical application of US image analysis and describing some probable future trends in this important area of ultrasonic imaging research.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V
2012-08-01
At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.
Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2013-01-01
Presently, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures which provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high resolution images, it is also safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically-specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically-relevant depths, ideal for soft tissue imaging. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, enabling multi-modality imaging with complementary contrast. Here, we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and demonstrate its ability to image internal organs in vivo, illustrating its potential clinical application. PMID:22797808
Remote consulting based on ultrasonic digital immages and dynamic ultrasonic sequences
NASA Astrophysics Data System (ADS)
Margan, Anamarija; Rustemović, Nadan
2006-03-01
Telematic ultrasonic diagnostics is a relatively new tool in providing health care to patients in remote, islolated communities. Our project facility, "The Virtual Polyclinic - A Specialists' Consulting Network for the Islands", is located on the island of Cres in the Adriatic Sea in Croatia and has been extending telemedical services to the archipelago population since 2000. Telemedicine applications include consulting services by specialists at the University Clinical Hospital Center Rebro in Zagreb and at "Magdalena", a leading cardiology clinic in Croatia. After several years of experience with static high resolution ultrasonic digital immages for referral consulting diagnostics purposes, we now also use dynamic ultrasonic sequences in a project with the Department of Emmergency Gastroenterology at Rebro in Zagreb. The aim of the ongoing project is to compare the advantages and shortcomings in transmitting static ultrasonic digital immages and live sequences of ultrasonic examination in telematic diagnostics. Ultrasonic examination is a dynamic process in which the diagnostic accuracy is highly dependent on the dynamic moment of an ultrasound probe and signal. Our first results indicate that in diffuse parenchymal organ pathology the progression and the follow up of a disease is better presented to a remote consulting specialist by dynamic ultrasound sequences. However, the changes that involve only one part of a parenchymal organ can be suitably presented by static ultrasonic digital images alone. Furthermore, we need less time for digital imaging and such tele-consultations overall are more economical. Our previous telemedicine research and practice proved that we can greatly improve the level of medical care in remote healthcare facilities and cut healthcare costs considerably. The experience in the ongoing project points to a conclusion that we can further optimize remote diagnostics benefits by a right choice of telematic application thus reaching a correct diagnosis and starting an applicable therapy even faster. Nevertheless, a successful implementation of such diagnostics methods may require further improvements in telemedical systems.
Plastic Deformation Behavior of Ti Foil Under Ultrasonic Vibration in Tension
NASA Astrophysics Data System (ADS)
Jiang, Shaosong; Jia, Yong; Zhang, Hongbin; Du, Zhihao; Lu, Zhen; Zhang, Kaifeng; He, Yushi; Wang, Ruizhuo
2017-04-01
The benefits of ultrasonic vibration auxiliary metal forming have been shown by many studies. In this study, a series of experiments were carried out to investigate the deformation behavior of Ti foils under ultrasonic vibration in tension, and the tensile properties of Ti foils with/without the application of ultrasonic vibration were investigated. Then, the microstructure of different tensile samples was analyzed by transmission electron microscopy (TEM). The results of the tensile experiments showed that the tensile strength of tensile samples was reduced when ultrasonic vibration was applied, while the elongation of these samples increased. The flow stress increased with increasing strain without applying ultrasonic vibration, while it decreased steeply when the ultrasonic vibration was applied, and this reduction of flow stress demonstrated the effect of acoustic softening on the properties of the material. Additionally, the range of flow stress reduction was inversely proportional to the time for which ultrasonic vibration was applied. The TEM images showed that there were remarkable differences in dislocation distribution and tangles with/without ultrasonic vibration. The dislocation distribution was inhomogeneous, and copious dislocation tangles were discovered without ultrasonic vibration. When it was applied, the parallel re-arrangement of dislocations could be observed and the mass of dislocation tangles was mostly absent.
In vivo microwave-based thermoacoustic tomography of rats (Conference Presentation)
NASA Astrophysics Data System (ADS)
Lin, Li; Zhou, Yong; Wang, Lihong V.
2016-03-01
Microwave-based thermoacoustic tomography (TAT), based on the measurement of ultrasonic waves induced by microwave pulses, can reveal tissue dielectric properties that may be closely related to the physiological and pathological status of the tissues. Using microwaves as the excitation source improved imaging depth because of their deep penetration into biological tissues. We demonstrate, for the first time, in vivo microwave-based thermoacoustic imaging in rats. The transducer is rotated around the rat in a full circle, providing a full two-dimensional view. Instead of a flat ultrasonic transducer, we used a virtual line detector based on a cylindrically focused transducer. A 3 GHz microwave source with 0.6 µs pulse width and an electromagnetically shielded transducer with 2.25 MHz central frequency provided clear cross-sectional images of the rat's body. The high imaging contrast, based on the tissue's rate of absorption, and the ultrasonically defined spatial resolution combine to reveal the spine, kidney, muscle, and other deeply seated anatomical features in the rat's abdominal cavity. This non-invasive and non-ionizing imaging modality achieved an imaging depth beyond 6 cm in the rat's tissue. Cancer diagnosis based on information about tissue properties from microwave band TAT can potentially be more accurate than has previously been achievable.
NASA Astrophysics Data System (ADS)
Kraft, Silvan; Karamalis, Athanasios; Sheet, Debdoot; Drecoll, Enken; Rummeny, Ernst J.; Navab, Nassir; Noël, Peter B.; Katouzian, Amin
2013-03-01
Medical ultrasonic grayscale images are formed from acoustic waves following their interactions with distributed scatterers within tissues media. For accurate simulation of acoustic wave propagation, a reliable model describing unknown parameters associated with tissues scatterers such as distribution, size and acoustic properties is essential. In this work, we introduce a novel approach defining ultrasonic scatterers by incorporating a distribution of cellular nuclei patterns in biological tissues to simulate ultrasonic response of atherosclerotic tissues in intravascular ultrasound (IVUS). For this reason, a virtual phantom is generated through manual labeling of different tissue types (fibrotic, lipidic and calcified) on histology sections. Acoustic properties of each tissue type are defined by assuming that the ultrasound signal is primarily backscattered by the nuclei of the organic cells within the intima and media of the vessel wall. This resulting virtual phantom is subsequently used to simulate ultrasonic wave propagation through the tissue medium computed using finite difference estimation. Subsequently B-mode images for a specific histological section are processed from the simulated radiofrequency (RF) data and compared with the original IVUS of the same tissue section. Real IVUS RF signals for these histological sections were obtained using a single-element mechanically rotating 40MHz transducer. Evaluation is performed by trained reviewers subjectively assessing both simulated and real B-mode IVUS images. Our simulation platform provides a high image quality with a very promising correlation to the original IVUS images. This will facilitate to better understand progression of such a chronic disease from micro-level and its integration into cardiovascular disease-specific models.
Air-Coupled Ultrasonic Measurements in Composites
NASA Astrophysics Data System (ADS)
Kommareddy, V.; Peters, J. J.; Dayal, V.; Hsu, D. K.
2004-02-01
Air-coupled ultrasound is a non-contact technique and has clear advantages over water-coupled testing. Research of air-coupled ultrasonics, especially using capacitance and micromachined transducers, has been extensively reported in the literature. This paper reports our experience of applying piezoceramic air-coupled transducers for nondestructive evaluation of composites. The beam profiles of air-coupled piezoceramic transducers, with and without apodization, were mapped out. The transmission of air-coupled ultrasonic energy through composite plates of different thickness was measured experimentally; model calculation of the transmission coefficient, taking into account the frequency bandwidth of the transducer, agreed with the measurement results. The occurrence of diffraction phenomenon ("Poisson bright spot") while imaging flaws in composite laminates was investigated. The resolution of scanned images obtained with air-coupled transducers was investigated for different frequency, focusing, and apodization conditions.
A 3D ultrasound scanner: real time filtering and rendering algorithms.
Cifarelli, D; Ruggiero, C; Brusacà, M; Mazzarella, M
1997-01-01
The work described here has been carried out within a collaborative project between DIST and ESAOTE BIOMEDICA aiming to set up a new ultrasonic scanner performing 3D reconstruction. A system is being set up to process and display 3D ultrasonic data in a fast, economical and user friendly way to help the physician during diagnosis. A comparison is presented among several algorithms for digital filtering, data segmentation and rendering for real time, PC based, three-dimensional reconstruction from B-mode ultrasonic biomedical images. Several algorithms for digital filtering have been compared as relates to processing time and to final image quality. Three-dimensional data segmentation techniques and rendering has been carried out with special reference to user friendly features for foreseeable applications and reconstruction speed.
A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy.
Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V
2012-10-08
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.
A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy
Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2012-01-01
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope’s instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. PMID:23188360
Hargreaves, J R; Busza, J; Mushati, P; Fearon, E; Cowan, F M
2017-06-01
HIV stigma can inhibit uptake of HIV testing and antiretroviral therapy as well as negatively affect mental health. Efforts to reduce discrimination against people living with HIV (LWH) have contributed to greater acceptance of the infection. Female sex workers (FSW) LWH may experience overlapping stigma due to both their work and HIV status, although this is poorly understood. We examined HIV and sex-work stigma experienced by FSW LWH in Zimbabwe. Using the SAPPH-IRe cluster-randomised trial baseline survey, we analysed the data from 1039 FSW self-reporting HIV. The women were recruited in 14 sites using respondent-driven sampling. We asked five questions to assess internalised and experienced stigma related to working as a sex worker, and the same questions were asked in reference to HIV. Among all FSW, 91% reported some form of sex-work stigma. This was not associated with sociodemographic or sex-work characteristics. Rates of sex-work stigma were higher than those of HIV-related stigma. For example, 38% reported being "talked badly about" for LWH compared with 77% for their involvement in sex work. Those who reported any sex-work stigma also reported experiencing more HIV stigma compared to those who did not report sex-work stigma, suggesting a layering effect. FSW in Zimbabwe experience stigma for their role as "immoral" women and this appears more prevalent than HIV stigma. As HIV stigma attenuates, other forms of social stigma associated with the disease may persist and continue to pose barriers to effective care.
Wessels, Jocelyn M.; Lajoie, Julie; Vitali, Danielle; Omollo, Kenneth; Kimani, Joshua; Oyugi, Julius; Cheruiyot, Juliana; Kimani, Makubo; Mungai, John N.; Akolo, Maureen; Stearns, Jennifer C.; Surette, Michael G.; Fowke, Keith R.
2017-01-01
Objective To compare the vaginal microbiota of women engaged in high-risk sexual behaviour (sex work) with women who are not engaged in high-risk sexual behaviour. Diverse vaginal microbiota, low in Lactobacillus species, like those in bacterial vaginosis (BV), are associated with increased prevalence of sexually transmitted infections (STIs) and human immunodeficiency virus (HIV) acquisition. Although high-risk sexual behaviour increases risk for STIs, the vaginal microbiota of sex workers is understudied. Methods A retrospective cross-sectional study was conducted comparing vaginal microbiota of women who are not engaged in sex work (non-sex worker controls, NSW, N = 19) and women engaged in sex work (female sex workers, FSW, N = 48), using Illumina sequencing (16S rRNA, V3 region). Results Bacterial richness and diversity were significantly less in controls, than FSW. Controls were more likely to have Lactobacillus as the most abundant genus (58% vs. 17%; P = 0.002) and composition of their vaginal microbiota differed from FSW (PERMANOVA, P = 0.001). Six microbiota clusters were detected, including a high diversity cluster with three sub-clusters, and 55% of women with low Nugent Scores fell within this cluster. High diversity was observed by 16S sequencing in FSW, regardless of Nugent Scores, suggesting that Nugent Score may not be capable of capturing the diversity present in the FSW vaginal microbiota. Conclusions High-risk sexual behaviour is associated with diversity of the vaginal microbiota and lack of Lactobacillus. These factors could contribute to increased risk of STIs and HIV in women engaged in high-risk sexual behaviour. PMID:29095928
Wessels, Jocelyn M; Lajoie, Julie; Vitali, Danielle; Omollo, Kenneth; Kimani, Joshua; Oyugi, Julius; Cheruiyot, Juliana; Kimani, Makubo; Mungai, John N; Akolo, Maureen; Stearns, Jennifer C; Surette, Michael G; Fowke, Keith R; Kaushic, Charu
2017-01-01
To compare the vaginal microbiota of women engaged in high-risk sexual behaviour (sex work) with women who are not engaged in high-risk sexual behaviour. Diverse vaginal microbiota, low in Lactobacillus species, like those in bacterial vaginosis (BV), are associated with increased prevalence of sexually transmitted infections (STIs) and human immunodeficiency virus (HIV) acquisition. Although high-risk sexual behaviour increases risk for STIs, the vaginal microbiota of sex workers is understudied. A retrospective cross-sectional study was conducted comparing vaginal microbiota of women who are not engaged in sex work (non-sex worker controls, NSW, N = 19) and women engaged in sex work (female sex workers, FSW, N = 48), using Illumina sequencing (16S rRNA, V3 region). Bacterial richness and diversity were significantly less in controls, than FSW. Controls were more likely to have Lactobacillus as the most abundant genus (58% vs. 17%; P = 0.002) and composition of their vaginal microbiota differed from FSW (PERMANOVA, P = 0.001). Six microbiota clusters were detected, including a high diversity cluster with three sub-clusters, and 55% of women with low Nugent Scores fell within this cluster. High diversity was observed by 16S sequencing in FSW, regardless of Nugent Scores, suggesting that Nugent Score may not be capable of capturing the diversity present in the FSW vaginal microbiota. High-risk sexual behaviour is associated with diversity of the vaginal microbiota and lack of Lactobacillus. These factors could contribute to increased risk of STIs and HIV in women engaged in high-risk sexual behaviour.
Luo, Binhua; Liang, Huageng; Zhang, Shengwei; Qin, Xiaojuan; Liu, Xuhan; Liu, Wei; Zeng, Fuqing; Wu, Yun; Yang, Xiangliang
2015-01-01
In the study reported here, a novel amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) (PAEEP-PLLA) copolymer was synthesized by ring-opening polymerization reaction. The perfluoropentane-filled PAEEP-PLLA nanobubbles (NBs) were prepared using the O1/O2/W double-emulsion and solvent-evaporation method, with the copolymer as the shell and liquid perfluoropentane as the core of NBs. The prepared NBs were further conjugated with lactoferrin (Lf) for tumor-cell targeting. The resulting Lf-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) nanobubbles (Lf-PAEEP-PLLA NBs) were characterized by photon correlation spectroscopy, polyacrylamide gel electrophoresis, Fourier transform infrared spectroscopy, and transmission electron microscopy. The average size of the Lf-PAEEP-PLLA NBs was 328.4±5.1 nm, with polydispersity index of 0.167±0.020, and zeta potential of −12.6±0.3 mV. Transmission electron microscopy imaging showed that the Lf-PAEEP-PLLA NBs had a near-spherical structure, were quite monodisperse, and there was a clear interface between the copolymer shell and the liquid core inside the NBs. The Lf-PAEEP-PLLA NBs also exhibited good biocompatibility in cytotoxicity and hemolysis studies and good stability during storage. The high cellular uptake of Lf-PAEEP-PLLA NBs in C6 cells (low-density lipoprotein receptor-related protein 1-positive cells) at concentrations of 0–20 µg/mL indicated that the Lf provided effective targeting for brain-tumor cells. The in vitro acoustic behavior of Lf-PAEEP-PLLA NBs was evaluated using a B-mode clinical ultrasound imaging system. In vivo ultrasound imaging was performed on tumor-bearing BALB/c nude mice, and compared with SonoVue® microbubbles, a commercial ultrasonic contrast agent. Both in vitro and in vivo ultrasound imaging indicated that the Lf-PAEEP-PLLA NBs possessed strong, long-lasting, and tumor-enhanced ultrasonic contrast ability. Taken together, these results indicate that Lf-PAEEP-PLLA NBs represent a promising nano-sized ultrasonic contrast agent for tumor-targeting ultrasonic imaging. PMID:26396514
Luo, Binhua; Liang, Huageng; Zhang, Shengwei; Qin, Xiaojuan; Liu, Xuhan; Liu, Wei; Zeng, Fuqing; Wu, Yun; Yang, Xiangliang
2015-01-01
In the study reported here, a novel amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) (PAEEP-PLLA) copolymer was synthesized by ring-opening polymerization reaction. The perfluoropentane-filled PAEEP-PLLA nanobubbles (NBs) were prepared using the O1/O2/W double-emulsion and solvent-evaporation method, with the copolymer as the shell and liquid perfluoropentane as the core of NBs. The prepared NBs were further conjugated with lactoferrin (Lf) for tumor-cell targeting. The resulting Lf-conjugated amphiphilic poly(aminoethyl ethylene phosphate)/poly(L-lactide) nanobubbles (Lf-PAEEP-PLLA NBs) were characterized by photon correlation spectroscopy, polyacrylamide gel electrophoresis, Fourier transform infrared spectroscopy, and transmission electron microscopy. The average size of the Lf-PAEEP-PLLA NBs was 328.4±5.1 nm, with polydispersity index of 0.167±0.020, and zeta potential of -12.6±0.3 mV. Transmission electron microscopy imaging showed that the Lf-PAEEP-PLLA NBs had a near-spherical structure, were quite monodisperse, and there was a clear interface between the copolymer shell and the liquid core inside the NBs. The Lf-PAEEP-PLLA NBs also exhibited good biocompatibility in cytotoxicity and hemolysis studies and good stability during storage. The high cellular uptake of Lf-PAEEP-PLLA NBs in C6 cells (low-density lipoprotein receptor-related protein 1-positive cells) at concentrations of 0-20 µg/mL indicated that the Lf provided effective targeting for brain-tumor cells. The in vitro acoustic behavior of Lf-PAEEP-PLLA NBs was evaluated using a B-mode clinical ultrasound imaging system. In vivo ultrasound imaging was performed on tumor-bearing BALB/c nude mice, and compared with SonoVue(®) microbubbles, a commercial ultrasonic contrast agent. Both in vitro and in vivo ultrasound imaging indicated that the Lf-PAEEP-PLLA NBs possessed strong, long-lasting, and tumor-enhanced ultrasonic contrast ability. Taken together, these results indicate that Lf-PAEEP-PLLA NBs represent a promising nano-sized ultrasonic contrast agent for tumor-targeting ultrasonic imaging.
Software Cost Estimation Using a Decision Graph Process: A Knowledge Engineering Approach
NASA Technical Reports Server (NTRS)
Stukes, Sherry; Spagnuolo, John, Jr.
2011-01-01
This paper is not a description per se of the efforts by two software cost analysts. Rather, it is an outline of the methodology used for FSW cost analysis presented in a form that would serve as a foundation upon which others may gain insight into how to perform FSW cost analyses for their own problems at hand.
Federal Student aid Handbook, 2002-2003. Volume 6: Federal Work-Study.
ERIC Educational Resources Information Center
Office of Federal Student Aid (ED), Washington, DC.
The Federal Work-Study (FWS) Program allows undergraduate and graduate students to work part-time to help pay for the cost of their education. Schools must use 75% of their FSW Program funds to compensate students employed in community service jobs. This volume describes the ways schools are required to use money from FSW program funds to…
2011-01-01
expensive post-weld machining; and (g) low 102 environmental impact . However, some disadvantages of the 103 FSW process have also been identified such as (a...material. Its 443 density and thermal properties are next set to that of AISI- H13 , 444 a hot-worked tool steel, frequently used as the FSW-tool 445
2011-12-30
which reduces the need for expensive post-weld machining; and (g) low environmental impact . However, some disadvantages of the FSW process have also...next set to that of AISI- H13 , a hot-worked tool steel, frequently used as the FSW-tool material (Ref 16). The work-piece material is assumed to be
Why female sex workers participate in HIV research: the illusion of voluntariness.
Reed, Elizabeth; Fisher, Celia B; Blankenship, Kim M; West, Brooke S; Khoshnood, Kaveh
2017-07-01
The purpose of this study was to examine factors influencing the motivation for and perceived voluntariness of participation in non-intervention HIV research among female sex workers (FSW) in India. FSW (n = 30) who participated in non-intervention HIV studies in the previous three years were recruited from a local community-based organization. Semi-structured qualitative interviews focused on women's personal and economic motivations for participation and their perceptions of the informed consent process. Interviews were audio-recorded, translated, transcribed, and reviewed for common themes. Content analysis indicated that while many women reported willing participation, reports of obligatory participation were also a common theme. Obligations included money-related pressures and coercion by other FSW, social pressures, not wanting to disappoint the researchers, and perceiving that they had a contractual agreement to complete participation as a result of signing the consent form. Findings suggest a need for additional efforts during and following informed consent to prevent obligatory participation in HIV research studies among FSW. Findings emphasize the importance of integrating ongoing participant feedback into research ethics practices to identify issues not well addressed via standard ethics protocols when conducting HIV research among vulnerable populations.
NASA Astrophysics Data System (ADS)
Zhang, H. J.; Wang, M.; Zhu, Z.; Zhang, X.; Yu, T.; Wu, Z. Q.
2018-03-01
High-rotation-speed friction stir welding (HRS-FSW) is a promising technique to reduce the welding loads during FSW and thus facilitates the application of FSW for in situ fabrication and repair. In this study, 6061 aluminum alloy was friction stir welded at high-rotation speeds ranging from 3000 to 7000 rpm at a fixed welding speed of 50 mm/min, and the effects of rotation speed on the nugget zone macro- and microstructures were investigated in detail in order to illuminate the process features. Temperature measurements during HRS-FSW indicated that the peak temperature did not increase consistently with rotation speed; instead, it dropped remarkably at 5000 rpm because of the lowering of material shear stress. The nugget size first increased with rotation speed until 5000 rpm and then decreased due to the change of the dominant tool/workpiece contact condition from sticking to sliding. At the rotation speed of 5000 rpm, where the weld material experienced weaker thermal effect and higher-strain-rate plastic deformation, the nugget exhibited relatively small grain size, large textural intensity, and high dislocation density. Consequently, the joint showed superior nugget hardness and simultaneously a slightly low tensile ductility.
Microstructural Evolution in Friction Stir Welding of Ti-6Al-4V
NASA Technical Reports Server (NTRS)
Rubisoff, H.; Querin, J.; Magee, D.; Schneider, J.
2008-01-01
Friction stir welding (FSW) is a thermo-mechanical process that utilizes a nonconsumable rotating pin tool to consolidate a weld joint. In the conventional FSW process, the pin tool is responsible for generating both the heat required to soften the material and the forces necessary to deform and combine the weld seam. As such, the geometry of the pin tool is important to the quality of the weld and the process parameters required to produce the weld. Because the geometry of the pin tool is limitless, a reduced set of pin tools was formed to systematically study their effect on the weldment with respect to mechanical properties and resultant microstructure. In this study 0deg, 15deg, 30deg, 45deg, and 60deg tapered, microwave sintered, tungsten carbide (WC) pin tools were used to FSW Ti-6Al-4V. Transverse sections of the weld were used to test for mechanical properties and to document the microstructure using optical microscopy. X-ray diffraction (XRD) was also used to characterize the microstructure in the welds. FSW results for the 45deg and 60deg pin tools are reported in this paper.
NASA Astrophysics Data System (ADS)
Constantin, M. A.; Boșneag, A.; Nitu, E.; Iordache, M.
2017-10-01
Welding copper and its alloys is usually difficult to join by conventional fusion welding processes because of high thermal diffusivity of the copper, alloying elements, necessity of using a shielding gas and a clean surface. To overcome this inconvenience, Friction Stir Welding (FSW), a solid state joining process that relies on frictional heating and plastic deformation, is used as a feasible welding process. In order to achieve an increased welding speed and a reduction in tool wear, this process is assisted by another one (WIG) which generates and adds heat to the process. The aim of this paper is to identify the influence of the additional heat on the process parameters and on the welding joint properties (distribution of the temperature, hardness and roughness). The research includes two experiments for the FSW process and one experiment for tungsten inert gas assisted FSW process. The outcomes of the investigation are compared and analysed for both welding variants. Adding a supplementary heat source, the plates are preheated and are obtain some advantages such as reduced forces used in process and FSW tool wear, faster and better plasticization of the material, increased welding speed and a proper weld quality.
Kerrigan, Deanna; Barrington, Clare; Donastorg, Yeycy; Perez, Martha; Galai, Noya
2016-09-01
Female sex workers (FSW) are disproportionately affected by HIV. Yet, few interventions address the needs of FSW living with HIV. We developed a multi-level intervention, Abriendo Puertas (Opening Doors), and assessed its feasibility and effectiveness among a cohort of 250 FSW living with HIV in the Dominican Republic. We conducted socio-behavioral surveys and sexually transmitted infection and viral load testing at baseline and 10-month follow-up. We assessed changes in protected sex and adherence to antiretroviral therapy (ART) with logistic regression using generalized estimating equations. Significant pre-post intervention changes were documented for adherence (72-89 %; p < 0.001) and protected sex (71-81 %; p < 0.002). Higher intervention exposure was significantly associated with changes in adherence (AOR 2.42; 95 % CI 1.23-4.51) and protected sex (AOR 1.76; 95 % CI 1.09-2.84). Illicit drug use was negatively associated with both ART adherence and protected sex. Abriendo Puertas is feasible and effective in improving behavioral HIV outcomes in FSW living with HIV.
A Framework for Sexual Decision-Making Among Female Sex Workers in Jamaica.
Bailey, Althea; Figueroa, J Peter
2016-05-01
The Jamaican government has provided targeted HIV and sexually transmitted infection prevention, treatment, and other services for female sex workers (FSW) since 1989. HIV prevalence among FSW declined from 20 to 12% between 1989 and 1994, then to 9% in 2005, 5% in 2008, and 4.1% in 2011. This article distills the literature and two decades of experience working with FSW in Jamaica. Drawing on the constant comparative method, we put forward an innovative conceptual framework for explaining sexual decision-making and risk behaviors within both transactional and relational sexual situations. This framework helps fill the gaps in existing models that focus on individual behaviors. The model identifies interactions between environmental and structural elements of sex work, and three individual-level factors: risk perception, perceived relationship intimacy, and perceived control, as the four primary mediating factors influencing sexual decision-making among FSW. We propose that other factors such as violence, socioeconomic vulnerability, and policy/legal frameworks influence sexual decision-making through these primary mediating factors. This conceptual model may offer a useful framework for planning and evaluating prevention interventions among sex workers. However, it remains to be tested in order to establish its value.
Development strategies for the satellite flight software on-board Meteosat Third Generation
NASA Astrophysics Data System (ADS)
Tipaldi, Massimo; Legendre, Cedric; Koopmann, Olliver; Ferraguto, Massimo; Wenker, Ralf; D'Angelo, Gianni
2018-04-01
Nowadays, satellites are becoming increasingly software dependent. Satellite Flight Software (FSW), that is to say, the application software running on the satellite main On-Board Computer (OBC), plays a relevant role in implementing complex space mission requirements. In this paper, we examine relevant technical approaches and programmatic strategies adopted for the development of the Meteosat Third Generation Satellite (MTG) FSW. To begin with, we present its layered model-based architecture, and the means for ensuring a robust and reliable interaction among the FSW components. Then, we focus on the selection of an effective software development life cycle model. In particular, by combining plan-driven and agile approaches, we can fulfill the need of having preliminary SW versions. They can be used for the elicitation of complex system-level requirements as well as for the initial satellite integration and testing activities. Another important aspect can be identified in the testing activities. Indeed, very demanding quality requirements have to be fulfilled in satellite SW applications. This manuscript proposes a test automation framework, which uses an XML-based test procedure language independent of the underlying test environment. Finally, a short overview of the MTG FSW sizing and timing budgets concludes the paper.
NASA Technical Reports Server (NTRS)
Lee, J. A.; Carter, R. W.; Ding, J.
1999-01-01
This technical memorandum describes an investigation of using friction stir welding (FSW) process for joining a variety of aluminum metal matrix composites (MMC's) reinforced with discontinuous silicon-carbide (SiC) particulate and functional gradient materials. Preliminary results show that FSW is feasible to weld aluminum MMC to MMC or to aluminum-lithium 2195 if the SiC reinforcement is <25 percent by volume fraction. However, a softening in the heat-affected zone was observed and is known to be one of the major limiting factors for joint strength. The pin tool's material is made from a low-cost steel tool H-13 material, and the pin tool's wear was excessive such that the pin tool length has to be manually adjusted for every 5 ft of weldment. Initially, boron-carbide coating was developed for pin tools, but it did not show a significant improvement in wear resistance. Basically, FSW is applicable mainly for butt joining of flat plates. Therefore, FSW of cylindrical articles such as a flange to a duct with practical diameters ranging from 2-5 in. must be fully demonstrated and compared with other proven MMC joining techniques for cylindrical articles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Y.; Fung, S.; Wang, Q.
2015-06-29
This paper presents an ultrasonic fingerprint sensor based on a 24 × 8 array of 22 MHz piezoelectric micromachined ultrasonic transducers (PMUTs) with 100 μm pitch, fully integrated with 180 nm complementary metal oxide semiconductor (CMOS) circuitry through eutectic wafer bonding. Each PMUT is directly bonded to a dedicated CMOS receive amplifier, minimizing electrical parasitics and eliminating the need for through-silicon vias. The array frequency response and vibration mode-shape were characterized using laser Doppler vibrometry and verified via finite element method simulation. The array's acoustic output was measured using a hydrophone to be ∼14 kPa with a 28 V input, in reasonable agreement with predication from analyticalmore » calculation. Pulse-echo imaging of a 1D steel grating is demonstrated using electronic scanning of a 20 × 8 sub-array, resulting in 300 mV maximum received amplitude and 5:1 contrast ratio. Because the small size of this array limits the maximum image size, mechanical scanning was used to image a 2D polydimethylsiloxane fingerprint phantom (10 mm × 8 mm) at a 1.2 mm distance from the array.« less
NDE of hybrid armor structures using acoustography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhu, Jaswinder S.; Pergantis, Charles G.
2011-06-23
The US Army is investigating the use of composite materials to deliver lightweight and more effective armor protection systems to soldiers and other army assets. However, widespread use of such hybrid armor will require a reliable but fast NDE methodology to ensure integrity of these components during manufacturing and while in service. Traditional ultrasonic inspection of such hybrid armor structures may prove to be very effective, but point-by-point ultrasonic scanning is inherently time-consuming and manufacturing slowdowns could develop in high-volume production of such armor systems. In this paper, we report on the application of acoustography for the NDE of hybridmore » armor structures. Acoustography differs from conventional ultrasonic testing in that test objects are inspected in full field, analogously to real time x-ray imaging. The approach uses a novel, super high resolution large area acousto-optic (AO) sensor, which allows image formation through simple ultrasound shadow casting, analogous to x-ray image formation. This NDE approach offers significant inspection speed advantage over conventional point-by-point ultrasonic scanning procedures and is well-suited for high volume production. We will report initial results on a number of hybrid armor plate specimens employing composite materials that are being investigated by the US Army. Acoustography NDE results will also be verified using other complimentary NDE methods.« less
X-ray-induced acoustic computed tomography of concrete infrastructure
NASA Astrophysics Data System (ADS)
Tang, Shanshan; Ramseyer, Chris; Samant, Pratik; Xiang, Liangzhong
2018-02-01
X-ray-induced Acoustic Computed Tomography (XACT) takes advantage of both X-ray absorption contrast and high ultrasonic resolution in a single imaging modality by making use of the thermoacoustic effect. In XACT, X-ray absorption by defects and other structures in concrete create thermally induced pressure jumps that launch ultrasonic waves, which are then received by acoustic detectors to form images. In this research, XACT imaging was used to non-destructively test and identify defects in concrete. For concrete structures, we conclude that XACT imaging allows multiscale imaging at depths ranging from centimeters to meters, with spatial resolutions from sub-millimeter to centimeters. XACT imaging also holds promise for single-side testing of concrete infrastructure and provides an optimal solution for nondestructive inspection of existing bridges, pavement, nuclear power plants, and other concrete infrastructure.
Stimulated Raman photoacoustic imaging
Yakovlev, Vladislav V.; Zhang, Hao F.; Noojin, Gary D.; Denton, Michael L.; Thomas, Robert J.; Scully, Marlan O.
2010-01-01
Achieving label-free, molecular-specific imaging with high spatial resolution in deep tissue is often considered the grand challenge of optical imaging. To accomplish this goal, significant optical scattering in tissues has to be overcome while achieving molecular specificity without resorting to extrinsic labeling. We demonstrate the feasibility of developing such an optical imaging modality by combining the molecularly specific stimulated Raman excitation with the photoacoustic detection. By employing two ultrashort excitation laser pulses, separated in frequency by the vibrational frequency of a targeted molecule, only the specific vibrational level of the target molecules in the illuminated tissue volume is excited. This targeted optical absorption generates ultrasonic waves (referred to as stimulated Raman photoacoustic waves) which are detected using a traditional ultrasonic transducer to form an image following the design of the established photoacoustic microscopy. PMID:21059930
Novel Imaging Method of Continuous Shear Wave by Ultrasonic Color Flow Mapping
NASA Astrophysics Data System (ADS)
Yamakoshi, Yoshiki; Yamamoto, Atsushi; Yuminaka, Yasushi
Shear wave velocity measurement is a promising method in evaluation of tissue stiffness. Several methods have been developed to measure the shear wave velocity, however, it is difficult to obtain quantitative shear wave image in real-time by low cost system. In this paper, a novel shear wave imaging method for continuous shear wave is proposed. This method uses a color flow imaging which is used in ultrasonic imaging system to obtain shear wave's wavefront map. Two conditions, shear wave frequency condition and shear wave displacement amplitude condition, are required, however, these conditions are not severe restrictions in most applications. Using the proposed method, shear wave velocity of trapezius muscle is measured. The result is consistent with the velocity which is calculated from shear elastic modulus measured by ARFI method.
Estimation of the Scatterer Distribution of the Cirrhotic Liver using Ultrasonic Image
NASA Astrophysics Data System (ADS)
Yamaguchi, Tadashi; Hachiya, Hiroyuki
1998-05-01
In the B-mode image of the liver obtained by an ultrasonic imaging system, the speckled pattern changes with the progression of the disease such as liver cirrhosis.In this paper we present the statistical characteristics of the echo envelope of the liver, and the technique to extract information of the scatterer distribution from the normal and cirrhotic liver images using constant false alarm rate (CFAR) processing.We analyze the relationship between the extracted scatterer distribution and the stage of liver cirrhosis. The ratio of the area in which the amplitude of the processing signal is more than the threshold to the entire processed image area is related quantitatively to the stage of liver cirrhosis.It is found that the proposed technique is valid for the quantitative diagnosis of liver cirrhosis.
Risk factors for HIV infection among female sex workers in Bangui, Central African Republic.
Longo, Jean De Dieu; Simaleko, Marcel Mbeko; Diemer, Henri Saint-Calvaire; Grésenguet, Gérard; Brücker, Gilles; Belec, Laurent
2017-01-01
The aims of the study were i) to categorize female sex workers (FSW) according to socio-anthropologic criteria in Bangui; ii) to examine the association between a selection of demographic and risk variables with the different categories of female sex work as outcome, and iii) to investigate factors associated with HIV status. A cross-sectional questionnaire survey was conducted to describe the spectrum of commercial sex work in Bangui among 345 sexually active women. After collection of social and behavioral characteristics, each woman received a physical examination and a blood sample was taken for biological analyses, including HIV testing. The relationships between sociodemographic characteristics, behavioral variables involved in high risk for HIV as well as biological results were investigated by bivariate analysis in relationship with FSW categories as main outcomes, and by bivariate analysis followed by multivariate logistic regression analysis in relationship with HIV as the main outcome. The strength of statistical associations was measured by crude and adjusted Odds ratios (OR) and their 95% confidence intervals. The typology of FSW comprised six different categories. Two groups were the "official" professional FSW primarily classified according to their locations of work [i) "kata"(18.55%) representing women working in poor neighborhoods of Bangui; ii) "pupulenge" (13.91%) working in hotels and night clubs to seek white men]. Four groups were "clandestine" nonprofessional FSW classified according to their reported main activity [i) "market and street vendors" (20.86%); ii) "schoolgirls or students" (19.13%) involved in occasional transactional sex (during holidays); iii) "housewives or unemployed women" (15.65%); iv) "civil servants" (11.88%) working as soldiers or in the public sector]. The overall prevalence of HIV-1 was 19.12% (66/345). HIV varied according to FSW categories. Thus, among professional FSW, the HIV prevalence was 6-fold higher in "kata" than "pupulenge" (39.13% versus 6.30%; P = 0.001). Among nonprofessional FSW, the "vendors" showed the highest HIV prevalence (31.91%), which was higher than in "students" (6.10%; P = 0.001), "civil servants" (9.83%; P = 0.005), and "housewives" (13.00%; P = 0.01). In bivariate analysis, the following variables showed statistically significant association with risk for HIV infection: nationality; age of first sexual intercourse; self-assessment of HIV risk; knowledge of HIV status; anal sex practice with last clients; irregular condom use in last week; consumption of alcohol; other psycho-active substances; past history of STIs; HBs Ag; HSV-2 and bacterial vaginosis. However, the variable "sex workers categories" dichotomized into professional versus nonprofessional FSW was no longer associated with HIV. In multivariate logistical regression analysis, HIV infection was strongly associated with nationality (15.65% versus 3.77%) [adjusted OR (aOR) 3.39: 95% CI:1.25-9.16, P<0.05]; age of first sexual intercourse (21.10% versus 14.00%) (aOR 2.13: 95% CI: 1.03-4.39, P<0.05); anal sex practice with last clients (43.40% versus 11.50%) (aOR 4.31: 95% CI:2.28-8.33, P<0.001); irregular condom use in past week (33.50% versus 3.00%) (aOR 5.49: 95% CI:1.89-15.98, P<0.001); alcohol consumption before sex (34.70% versus 7.80%) (aOR 2.69: 95% CI:1.22-4.96, P<0.05); past history of STIs (41.00% versus 10.80%) (aOR 2.46: 95% CI:1.22-4.97, P<0.05) and bacterial vaginosis (29.80% versus 4.29%) (aOR 6.36: 95% CI: 2.30-17.72, P<0.001). Our observations highlight the high level of vulnerability for HIV acquisition of both poor professional "kata" and nonprofessional "street vendor" FSW categories. These categories should be particularly taken into account when designing specific prevention programs for STIs/HIV control purposes.
Jing, Bowen; Chigan, Pengju; Ge, Zhengtong; Wu, Liang; Wang, Supin; Wan, Mingxi
2017-01-01
For the purpose of noninvasively visualizing the dynamics of the contact between vibrating vocal fold medial surfaces, an ultrasonic imaging method which is referred to as array-based transmission ultrasonic glottography is proposed. An array of ultrasound transducers is used to detect the ultrasound wave transmitted from one side of the vocal folds to the other side through the small-sized contact between the vocal folds. A passive acoustic mapping method is employed to visualize and locate the contact. The results of the investigation using tissue-mimicking phantoms indicate that it is feasible to use the proposed method to visualize and locate the contact between soft tissues. Furthermore, the proposed method was used for investigating the movement of the contact between the vibrating vocal folds of excised canine larynges. The results indicate that the vertical movement of the contact can be visualized as a vertical movement of a high-intensity stripe in a series of images obtained by using the proposed method. Moreover, a visualization and analysis method, which is referred to as array-based ultrasonic kymography, is presented. The velocity of the vertical movement of the contact, which is estimated from the array-based ultrasonic kymogram, could reach 0.8 m/s during the vocal fold vibration. PMID:28599522
Study of a novel ultrasonically triggered drug vehicle with magnetic resonance properties.
Liu, Tse-Ying; Huang, Hsin-Hui; Chen, Yen-Ju; Chen, Yu-Jen
2011-02-01
We developed a novel ultrasonically triggered drug vehicle with magnetic resonance (MR) properties by encapsulating superparamagnetic iron oxide (SPIO) nanoparticles in hydroxyapatite (HA)-coated liposomes. The effects of HA coating on the background leakage, ultrasound response and MR signal were investigated. HA coating of liposomes significantly reduced the background leakage of liposome. It also enhanced their sensitivity to ultrasound regardless of HA thickness or ultrasound frequency, even under sonication conditions of high frequency (1 and 3 MHz) and low power density (0.2-0.4 Wcm(-2)) used for diagnosis. However, it was found that the ultrasonically triggered vehicle could exhibit T(2) contrast in MR images by encapsulating SPIO. However, HA coating reduced the r(2) value of SPIO encapsulated in liposomes, but had no significant effect on the r(2)(∗) value, implying that MR images of HA-coated liposomes encapsulating SPIO could be probed by the T(2)(∗) signal. Most importantly, the r(2)(∗)-r(2) value of HA-coated liposomes encapsulating SPIO decreased after sonication, suggesting that the proposed vehicle could be used not only as a MR-guided drug vehicle capable of ultrasonically triggered release but also as a MR reporter to probe ultrasonic triggering. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.
2002-01-01
The improvement in weld quality by the friction stir welding (FSW) process invented by TWI of Cambridge, England, patented in 1991, has prompted investigation of this process for advanced structural materials including Al metal matrix composite (Al-MMC) materials. Such materials can have high specific stiffness and other potential beneficial properties for the extreme environments in space. Developments of discontinuous reinforced Al-MMCs have found potential space applications and the future for such applications is quite promising. The space industry has recognized advantages of the FSW process over conventional welding processes such as the absence of a melt zone, reduced distortion, elimination of the need for shielding gases, and ease of automation. The process has been well proven for aluminum alloys, and work is being carried out for ferrous materials, magnesium alloys and copper alloys. Development work in the FSW welding process for joining of Al-MMCs is relatively recent and some of this and related work can be found in referenced research publications. NASA engineers have undertaken to spear head this research development work for FSW process investigation of Al-MMCs. Some of the reported related work has pointed out the difficulty in fusion welding of particulate reinforced MMCs where liquid Al will react with SiC to precipitate aluminum carbide (Al4C3). Advantages of no such reaction and no need for joint preparation for the FSW process is anticipated in the welding of Al-MMCs. The FSW process has been best described as a combination of extrusion and forging of metals. This is carried out as the pin tool rotates and is slowly plunged into the bond line of the joint as the pin tool's shoulder is in intimate contact with the work piece. The material is friction-stirred into a quality weld. Al-MMCs, 4 in. x 12 in. plates of 0.25 in. (6.35mm) thickness, procured from MMCC, Inc. were butt welded using FSW process at Marshall Space Flight Center (MSFC) using prior set of operating conditions. Weld quality was evaluated using radiography and standard metallography techniques. Another aspect of the MMCs centered around the use of the laser engineered net shaping (LENS) processing of selected Narloy-Z composites. Such an approach has been earlier studied for fabrication of stainless steels. In the present study, attempts were made to fabricate straight cylindrical specimens using LENS process of Narloy-Z and Narloy-Z with 20 vol. % Al2O3 MMCs using the direct metal deposition Optomec LENS-750 system.
NASA Technical Reports Server (NTRS)
Roth, Don J.
1991-01-01
The purpose of this dissertation was the following: (1) to characterize the effect of pore fraction on a comprehensive set of electrical and magnetic properties for the yttrium-barium-copper-oxide (YBCO) high temperature ceramic superconductor; and (2) to determine the viability of using a room-temperature, nondestructive characterization method to aid in the prediction of superconducting (cryogenic) properties. The latter involved correlating ultrasonic velocity measurements at room temperature with property-affecting pore fraction and oxygen content variations. The use of ultrasonic velocity for estimating pore fraction in YBCO is presented, and other polycrystalline materials are reviewed, modeled, and statistically analyzed. This provides the basis for using ultrasonic velocity to interrogate microstructure. The effect of pore fraction (0.10-0.25) on superconductor properties of YBCO samples was characterized. Spatial (within-sample) variations in microstructure and superconductor properties were investigated, and the effect of oxygen content on elastic behavior was examined. Experimental methods used included a.c. susceptibility, electrical, and ultrasonic velocity measurements. Superconductor properties measured included transition temperature, magnetic transition width, transport and magnetic critical current density, magnetic shielding, a.c. loss, and sharpness of the voltage-current characteristics. An ultrasonic velocity image constructed from measurements at 1mm increments across a YBCO sample revealed microstructural variations that correlated with variations in magnetic shielding and a.c. loss behavior. Destructive examination using quantitative image analysis revealed pore fraction to be the varying microstructural feature.
A Simple Model for Nonlinear Confocal Ultrasonic Beams
NASA Astrophysics Data System (ADS)
Zhang, Dong; Zhou, Lin; Si, Li-Sheng; Gong, Xiu-Fen
2007-01-01
A confocally and coaxially arranged pair of focused transmitter and receiver represents one of the best geometries for medical ultrasonic imaging and non-invasive detection. We develop a simple theoretical model for describing the nonlinear propagation of a confocal ultrasonic beam in biological tissues. On the basis of the parabolic approximation and quasi-linear approximation, the nonlinear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation is solved by using the angular spectrum approach. Gaussian superposition technique is applied to simplify the solution, and an analytical solution for the second harmonics in the confocal ultrasonic beam is presented. Measurements are performed to examine the validity of the theoretical model. This model provides a preliminary model for acoustic nonlinear microscopy.
1973-01-10
nitrogenous urinary metabolites and osmolarity ave been verified and extended to include electrolytes, ketogenic teroids and hydroxysteroids...epidemiological surveys of oral disease for interrelating the effects of climate, diet , oral care motivation and work activity. Oral health factors are monitored...from young rats saturated at 5D FSW days and 60 FSW for 35 days in air while receiving low, normal, and gh calcium diets . Samples from matur8 rats
NASA Technical Reports Server (NTRS)
Ding, Robert J.
2010-01-01
Some of the applications of advanced welding techniques are shown in this poster presentation. Included are brief explanations of the use on the Ares I and Ares V launch vehicle and on the Space Shuttle Launch vehicle. Also included are microstructural views from four advanced welding techniques: Variable Polarity Plasma Arc (VPPA) weld (fusion), self-reacting friction stir welding (SR-FSW), conventional FSW, and Tube Socket Weld (TSW) on aluminum.
Automation of Flight Software Regression Testing
NASA Technical Reports Server (NTRS)
Tashakkor, Scott B.
2016-01-01
NASA is developing the Space Launch System (SLS) to be a heavy lift launch vehicle supporting human and scientific exploration beyond earth orbit. SLS will have a common core stage, an upper stage, and different permutations of boosters and fairings to perform various crewed or cargo missions. Marshall Space Flight Center (MSFC) is writing the Flight Software (FSW) that will operate the SLS launch vehicle. The FSW is developed in an incremental manner based on "Agile" software techniques. As the FSW is incrementally developed, testing the functionality of the code needs to be performed continually to ensure that the integrity of the software is maintained. Manually testing the functionality on an ever-growing set of requirements and features is not an efficient solution and therefore needs to be done automatically to ensure testing is comprehensive. To support test automation, a framework for a regression test harness has been developed and used on SLS FSW. The test harness provides a modular design approach that can compile or read in the required information specified by the developer of the test. The modularity provides independence between groups of tests and the ability to add and remove tests without disturbing others. This provides the SLS FSW team a time saving feature that is essential to meeting SLS Program technical and programmatic requirements. During development of SLS FSW, this technique has proved to be a useful tool to ensure all requirements have been tested, and that desired functionality is maintained, as changes occur. It also provides a mechanism for developers to check functionality of the code that they have developed. With this system, automation of regression testing is accomplished through a scheduling tool and/or commit hooks. Key advantages of this test harness capability includes execution support for multiple independent test cases, the ability for developers to specify precisely what they are testing and how, the ability to add automation, and the ability of the harness and cases to be executed continually. This test concept is an approach that can be adapted to support other projects.
Optimization of ultrasonication period for better dispersion and stability of TiO2-water nanofluid.
Mahbubul, I M; Elcioglu, Elif Begum; Saidur, R; Amalina, M A
2017-07-01
Nanofluids are promising in many fields, including engineering and medicine. Stability deterioration may be a critical constraint for potential applications of nanofluids. Proper ultrasonication can improve the stability, and possibility of the safe use of nanofluids in different applications. In this study, stability properties of TiO 2 -H 2 O nanofluid for varying ultrasonication durations were tested. The nanofluids were prepared through two-step method; and electron microscopies, with particle size distribution and zeta potential analyses were conducted for the evaluation of their stability. Results showed the positive impact of ultrasonication on nanofluid dispersion properties up to some extent. Ultrasonication longer than 150min resulted in re-agglomeration of nanoparticles. Therefore, ultrasonication for 150min was the optimum period yielding highest stability. A regression analysis was also done in order to relate the average cluster size and ultrasonication time to zeta potential. It can be concluded that performing analytical imaging and colloidal property evaluation during and after the sample preparation leads to reliable insights. Copyright © 2017 Elsevier B.V. All rights reserved.
Experimental and simulated ultrasonic characterization of complex damage in fused silica.
Martin, L Peter; Chambers, David H; Thomas, Graham H
2002-02-01
The growth of a laser-induced, surface damage site in a fused silica window was monitored by the ultrasonic pulse-echo technique. The laser damage was grown using 12-ns pulses of 1.053-microm wavelength light at a fluence of approximately 27 J/cm2. The ultrasonic data were acquired after each pulse of the laser beam for 19 pulses. In addition, optical images of the surface and subsurface damage shape were recorded after each pulse of the laser. The ultrasonic signal amplitude exhibited variations with the damage size, which were attributed to the subsurface morphology of the damage site. A mechanism for the observed ultrasonic data based on the interaction of the ultrasound with cracks radiating from the damage site was tested using two-dimensional numerical simulations. The simulated results exhibit qualitatively similar characteristics to the experimental data and demonstrate the usefulness of numerical simulation as an aid for ultrasonic signal interpretation. The observed sensitivity to subsurface morphology makes the ultrasonic methodology a promising tool for monitoring laser damage in large aperture laser optics used in fusion energy research.
Dental hard tissue characterization using laser-based ultrasonics
NASA Astrophysics Data System (ADS)
Blodgett, David W.; Massey, Ward L.
2003-07-01
Dental health care and research workers require a means of imaging the structures within teeth in vivo. One critical need is the detection of tooth decay in its early stages. If decay can be detected early enough, the process can be monitored and interventional procedures, such as fluoride washes and controlled diet, can be initiated to help re-mineralize the tooth. Currently employed x-ray imaging is limited in its ability to visualize interfaces and incapable of detecting decay at a stage early enough to avoid invasive cavity preparation followed by a restoration. To this end, non-destructive and non-contact in vitro measurements on extracted human molars using laser-based ultrasonics are presented. Broadband ultrasonic waves are excited in the extracted sections by using a pulsed carbon-dioxide (CO2) laser operating in a region of high optical absorption in the dental hard tissues. Optical interferometric detection of the ultrasonic wave surface displacements in accomplished with a path-stabilized Michelson-type interferometer. Results for bulk and surface in-vitro characterization of caries are presented on extracted molars with pre-existing caries.
Assessment of probability of detection of delaminations in fiber-reinforced composites
NASA Technical Reports Server (NTRS)
Chern, E. J.; Chu, H. P.; Yang, J. N.
1991-01-01
Delamination is one of the critical defects in composite materials and structures. An ultrasonic C-scan imaging technique which maps out the acoustic impedance mismatched areas with respect to the sample coordinates, is particularly well suited for detecting and characterizing delaminations in composites. To properly interpret the results, it is necessary to correlate the indications with the detection limits and probability of detection (POD) of the ultrasonic C-scan imaging technique. The baseline information on the assessment of POD of delaminations in composite materials and structures is very beneficial to the evaluation of spacecraft materials. In this study, we review the principle of POD, describe the laboratory set-up and procedure, and present the experimental results as well as assessment of POD of delaminations in fiber reinforced composite panels using ultrasonic C-scan techniques.
Development of acoustic model-based iterative reconstruction technique for thick-concrete imaging
NASA Astrophysics Data System (ADS)
Almansouri, Hani; Clayton, Dwight; Kisner, Roger; Polsky, Yarom; Bouman, Charles; Santos-Villalobos, Hector
2016-02-01
Ultrasound signals have been used extensively for non-destructive evaluation (NDE). However, typical reconstruction techniques, such as the synthetic aperture focusing technique (SAFT), are limited to quasi-homogenous thin media. New ultrasonic systems and reconstruction algorithms are in need for one-sided NDE of non-homogenous thick objects. An application example space is imaging of reinforced concrete structures for commercial nuclear power plants (NPPs). These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Another example is geothermal and oil/gas production wells. These multi-layered structures are composed of steel, cement, and several types of soil and rocks. Ultrasound systems with greater penetration range and image quality will allow for better monitoring of the well's health and prediction of high-pressure hydraulic fracturing of the rock. These application challenges need to be addressed with an integrated imaging approach, where the application, hardware, and reconstruction software are highly integrated and optimized. Therefore, we are developing an ultrasonic system with Model-Based Iterative Reconstruction (MBIR) as the image reconstruction backbone. As the first implementation of MBIR for ultrasonic signals, this paper document the first implementation of the algorithm and show reconstruction results for synthetically generated data.1
Blankenship, Kim M; West, Brooke S; Kershaw, Trace S; Biradavolu, Monica R
2008-12-01
We used a structural interventions framework to analyse the associations between power and condom use among a sample of female sex workers (FSW), and how exposure to a local community mobilization intervention (CMI) affects these associations. Data came from a cross-sectional survey of 812 FSW in the East Godavari district of Andhra Pradesh, India, recruited through respondent-driven sampling. We identified three types of power - collective power, control over work, and economic power, and three dimensions of collective power - collective identity, efficacy, and agency. Multivariate logistic regression analysis was used to analyse the relationship of these three types of power and exposure to a CMI with consistent condom use with clients. A total of 803 respondents exchanged sex with an occasional or regular client in the 7 days before the interview. Multivariate logistic regression shows that control over both the type of sex [adjusted odds ratio (AOR) 1.70, 95% confidence interval (CI) 1.23-2.34] and the amount charged (AOR 1.56, 95% CI 1.12-2.16), and economic dependence (AOR 0.54, 95% CI 0.35-0.83) are associated with consistent condom use as is programme exposure (AOR 2.09, 95% CI 1.48-2.94). The interaction between programme exposure and collective agency was also significant (chi-square 6.62, P = 0.01). Among respondents who reported both programme exposure and high levels of collective agency, the odds ratio of consistent condom use was 2.5 times that of other FSW. A structural interventions framework is useful for understanding HIV risk among FSW. More needs to be done to promote FSW control over work and access to economic resources.
Valadez, Joseph J.; Berendes, Sima; Jeffery, Caroline; Thomson, Joanna; Ben Othman, Hussain; Danon, Leon; Turki, Abdullah A.; Saffialden, Rabea; Mirzoyan, Lusine
2013-01-01
Background Publications on Libya’s HIV epidemic mostly examined the victims of the tragic nosocomial HIV outbreak in the 1990s and the related dispute about the detention of foreign medical workers. The dispute resolution in 2003 included an agreement with the European Union on humanitarian cooperation and the development of Libya’s first National HIV Strategy. As part of this we conducted Libya’s first bio-behavioural survey among men having sex with men (MSM) and female sex workers (FSW). Methods Using respondent-driven sampling, we conducted a cross-sectional study to estimate the prevalence of HIV, hepatitis B virus (HBV), hepatitis C virus (HCV), and related risk factors among 227 MSM and 69 FSW in Tripoli (FSW recruitment ended prematurely due to the political events in 2011). Results For MSM we estimated an HIV prevalence of 3.1%, HBV prevalence of 2.9%, and HCV prevalence of 7.3%, and for FSW an HIV prevalence of 15.7%, HBV prevalence of 0%, and HCV prevalence of 5.2%. We detected high levels of risk behaviours, poor HIV-related knowledge, high stigma and lack of prevention programmes. These results must be interpreted in the context of the political situation which prohibited reaching an ideal sample size for FSW. Conclusion There is urgent need to implement an effective National HIV Strategy informed by the results of this research. The risk of transmission within different risk groups and to the general population may be high given the recent military events that led to increased violence, migration, and the disruption of essential HIV-related services. PMID:23840521
Investigation of Machine Design for Friction Stir Welding
NASA Technical Reports Server (NTRS)
Romine, Peter L.
1996-01-01
The process of joining two pieces of metal together has not significantly changed over the last few decades. The basic idea used is to bring the pieces together and apply enough heat to melt the metal at the interface. The molten metal mixes and after cooling forms a strong joint. This process is called the fusion process. The most significant difference between the many fusion processes is how the heat is generated and applied. The Welding Institute (TWI), in Great Britain, has recently patented an innovative application of mechanical friction. TWI designed a tool and process called Friction Stir Welding (FSW) that uses friction to heat the metal to within a few hundred degrees Fahrenheit of melting, just to the point of being plastic-like. The tool then stirs the plasticized metal together forming a joint that has been shown to be as good or better than an equivalent fusion joint. The FSW process is well suited for the joining of the aluminum alloys used in the aerospace industry. The relatively low melting point of aluminum eliminates the requirements for exotic materials for pin tool design. The FSW process has been successfully used to join alloys such as 7075 which were before considered "unweldable", and aluminum-lithium 2195 which exhibits many problems when fusion welded. The objective this summer was to investigate the design of a FSW system that could take this process from the laboratory to the manufacturing floor. In particular, it was the goal of my NASA colleague to develop a concept for applying the FSW process to the manufacturing of aluminum cryogenic oxygen and hydrogen tanks, of the sort used to make the Shuttle External Tank.
Strathdee, Steffanie A; Lozada, Remedios; Martinez, Gustavo; Vera, Alicia; Rusch, Melanie; Nguyen, Lucie; Pollini, Robin A; Uribe-Salas, Felipe; Beletsky, Leo; Patterson, Thomas L
2011-04-25
FSWs who inject drugs (FSW-IDUs) can acquire HIV through high risk sexual and injection behaviors. We studied correlates of HIV infection among FSW-IDUs in northern Mexico, where sex work is quasi-legal and syringes can be legally obtained without a prescription. FSW-IDUs>18 years old who reported injecting drugs and recent unprotected sex with clients in Tijuana and Ciudad Juarez underwent surveys and HIV/STI testing. Logistic regression identified correlates of HIV infection. Of 620 FSW-IDUs, prevalence of HIV, gonorrhea, Chlamydia, trichomonas, syphilis titers ≥1:8, or any of these infections was 5.3%, 4%, 13%, 35%, 10% and 72%, respectively. Compared to other FSW-IDUs, HIV-positive women were more likely to: have syphilis titers ≥1:8 (36% vs. 9%, p<0.001), often/always inject drugs with clients (55% vs. 32%, p = 0.01), and experience confiscation of syringes by police (49% vs. 28%, p = 0.02). Factors independently associated with HIV infection were syphilis titers ≥1:8, often/always injecting with clients and police confiscation of syringes. Women who obtained syringes from NEPs (needle exchange programs) within the last month had lower odds of HIV infection associated with active syphilis, but among non-NEP attenders, the odds of HIV infection associated with active syphilis was significantly elevated. Factors operating in both the micro-social environment (i.e., injecting drugs with clients) and policy environment (i.e., having syringes confiscated by police, attending NEPs) predominated as factors associated with risk of HIV infection, rather than individual-level risk behaviors. Interventions should target unjustified policing practices, clients' risk behaviors and HIV/STI prevention through NEPs.
Strathdee, Steffanie A.; Lozada, Remedios; Martinez, Gustavo; Vera, Alicia; Rusch, Melanie; Nguyen, Lucie; Pollini, Robin A.; Uribe-Salas, Felipe; Beletsky, Leo; Patterson, Thomas L.
2011-01-01
Background FSWs who inject drugs (FSW-IDUs) can acquire HIV through high risk sexual and injection behaviors. We studied correlates of HIV infection among FSW-IDUs in northern Mexico, where sex work is quasi-legal and syringes can be legally obtained without a prescription. Methods FSW-IDUs>18 years old who reported injecting drugs and recent unprotected sex with clients in Tijuana and Ciudad Juarez underwent surveys and HIV/STI testing. Logistic regression identified correlates of HIV infection. Results Of 620 FSW-IDUs, prevalence of HIV, gonorrhea, Chlamydia, trichomonas, syphilis titers ≥1∶8, or any of these infections was 5.3%, 4%, 13%, 35%, 10% and 72%, respectively. Compared to other FSW-IDUs, HIV-positive women were more likely to: have syphilis titers ≥1∶8 (36% vs. 9%, p<0.001), often/always inject drugs with clients (55% vs. 32%, p = 0.01), and experience confiscation of syringes by police (49% vs. 28%, p = 0.02). Factors independently associated with HIV infection were syphilis titers ≥1∶8, often/always injecting with clients and police confiscation of syringes. Women who obtained syringes from NEPs (needle exchange programs) within the last month had lower odds of HIV infection associated with active syphilis, but among non-NEP attenders, the odds of HIV infection associated with active syphilis was significantly elevated. Conclusions Factors operating in both the micro-social environment (i.e., injecting drugs with clients) and policy environment (i.e., having syringes confiscated by police, attending NEPs) predominated as factors associated with risk of HIV infection, rather than individual-level risk behaviors. Interventions should target unjustified policing practices, clients' risk behaviors and HIV/STI prevention through NEPs. PMID:21541349
High-Performance Scanning Acousto-Ultrasonic System
NASA Technical Reports Server (NTRS)
Roth, Don; Martin, Richard; Kautz, Harold; Cosgriff, Laura; Gyekenyesi, Andrew
2006-01-01
A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, Peter N. T.; Liang, Hai-Dong
2011-01-01
After X-radiography, ultrasound is now the most common of all the medical imaging technologies. For millennia, manual palpation has been used to assist in diagnosis, but it is subjective and restricted to larger and more superficial structures. Following an introduction to the subject of elasticity, the elasticity of biological soft tissues is discussed and published data are presented. The basic physical principles of pulse-echo and Doppler ultrasonic techniques are explained. The history of ultrasonic imaging of soft tissue strain and elasticity is summarized, together with a brief critique of previously published reviews. The relevant techniques—low-frequency vibration, step, freehand and physiological displacement, and radiation force (displacement, impulse, shear wave and acoustic emission)—are described. Tissue-mimicking materials are indispensible for the assessment of these techniques and their characteristics are reported. Emerging clinical applications in breast disease, cardiology, dermatology, gastroenterology, gynaecology, minimally invasive surgery, musculoskeletal studies, radiotherapy, tissue engineering, urology and vascular disease are critically discussed. It is concluded that ultrasonic imaging of soft tissue strain and elasticity is now sufficiently well developed to have clinical utility. The potential for further research is examined and it is anticipated that the technology will become a powerful mainstream investigative tool. PMID:21680780
Ultrasonic computed tomography imaging of iron oxide nanoparticles
NASA Astrophysics Data System (ADS)
Perlman, Or; Azhari, Haim
2017-02-01
Iron oxide nanoparticles (IONPs) are becoming increasingly used and intensively investigated in the field of medical imaging. They are currently FDA approved for magnetic resonance imaging (MRI), and it would be highly desirable to visualize them by ultrasound as well. Previous reports using the conventional ultrasound B-scan (pulse-echo) imaging technique have shown very limited detectability of these particles. The aim of this study is to explore the feasibility of imaging IONPs using the through-transmission ultrasound methodology and demonstrate their detectability using ultrasonic computed tomography (UCT). Commercially available IONPs were acoustically analysed to quantify their effect on the speed of sound (SOS) and acoustic attenuation as a function of concentration. Next, through-transmission projection and UCT imaging were performed on a breast mimicking phantom and on an ex vivo tissue model, to which IONPs were injected. Finally, an MRI scan was performed to verify that the same particles examined in the ultrasound experiment can be imaged by magnetic resonance, using the same clinically relevant concentrations. The results have shown a consistent concentration dependent speed of sound increase (1.86 \\text{m}{{\\text{s}}^{-1}} rise per 100 µg · ml-1 IONPs). Imaging based on this property has shown a substantial contrast-to-noise ratio improvement (up to 5 fold, p < 0.01). The SOS-related effect generated a well discernible image contrast and allowed the detection of the particles existence and location, in both raster-scan projection and UCT imaging. Conversely, no significant change in the acoustic attenuation coefficient was noted. Based on these findings, it is concluded that IONPs can be used as an effective SOS-based contrast agent, potentially useful for ultrasonic breast imaging. Furthermore, the particle offers the capacity of significantly enhancing diagnosis accuracy using multimodal MRI-ultrasound imaging capabilities.
NASA Astrophysics Data System (ADS)
Rajendran, C.; Srinivasan, K.; Balasubramanian, V.; Balaji, H.; Selvaraj, P.
2016-08-01
Friction stir welded (FSWed) joints of aluminum alloys exhibited a hardness drop in both the advancing side (AS) and retreating side (RS) of the thermo-mechanically affected zone (TMAZ) due to the thermal cycle involved in the FSW process. In this investigation, an attempt has been made to overcome this problem by post weld heat treatment (PWHT) methods. FSW butt (FSWB) joints of Al-Cu (AA2014-T6) alloy were PWHT by two methods such as simple artificial aging (AA) and solution treatment followed by artificial aging (STA). Of these two treatments, STA was found to be more beneficial than the simple aging treatment to improve the tensile properties of the FSW joints of AA2014 aluminum alloy.
Orion FSW V and V and Kedalion Engineering Lab Insight
NASA Technical Reports Server (NTRS)
Mangieri, Mark L.
2010-01-01
NASA, along with its prime Orion contractor and its subcontractor s are adapting an avionics system paradigm borrowed from the manned commercial aircraft industry for use in manned space flight systems. Integrated Modular Avionics (IMA) techniques have been proven as a robust avionics solution for manned commercial aircraft (B737/777/787, MD 10/90). This presentation will outline current approaches to adapt IMA, along with its heritage FSW V&V paradigms, into NASA's manned space flight program for Orion. NASA's Kedalion engineering analysis lab is on the forefront of validating many of these contemporary IMA based techniques. Kedalion has already validated many of the proposed Orion FSW V&V paradigms using Orion's precursory Flight Test Article (FTA) Pad Abort 1 (PA-1) program. The Kedalion lab will evolve its architectures, tools, and techniques in parallel with the evolving Orion program.
NASA Astrophysics Data System (ADS)
Park, Byeongjin; Sohn, Hoon
2017-07-01
Laser ultrasonic scanning, especially full-field wave propagation imaging, is attractive for damage visualization thanks to its noncontact nature, sensitivity to local damage, and high spatial resolution. However, its practicality is limited because scanning at a high spatial resolution demands a prohibitively long scanning time. Inspired by binary search, an accelerated damage visualization technique is developed to visualize damage with a reduced scanning time. The pitch-catch distance between the excitation point and the sensing point is also fixed during scanning to maintain a high signal-to-noise ratio (SNR) of measured ultrasonic responses. The approximate damage boundary is identified by examining the interactions between ultrasonic waves and damage observed at the scanning points that are sparsely selected by a binary search algorithm. Here, a time-domain laser ultrasonic response is transformed into a spatial ultrasonic domain response using a basis pursuit approach so that the interactions between ultrasonic waves and damage, such as reflections and transmissions, can be better identified in the spatial ultrasonic domain. Then, the area inside the identified damage boundary is visualized as damage. The performance of the proposed damage visualization technique is validated excusing a numerical simulation performed on an aluminum plate with a notch and experiments performed on an aluminum plate with a crack and a wind turbine blade with delamination. The proposed damage visualization technique accelerates the damage visualization process in three aspects: (1) the number of measurements that is necessary for damage visualization is dramatically reduced by a binary search algorithm; (2) the number of averaging that is necessary to achieve a high SNR is reduced by maintaining the wave propagation distance short; and (3) with the proposed technique, the same damage can be identified with a lower spatial resolution than the spatial resolution required by full-field wave propagation imaging.
Flaw imaging and ultrasonic techniques for characterizing sintered silicon carbide
NASA Technical Reports Server (NTRS)
Baaklini, George Y.; Abel, Phillip B.
1987-01-01
The capabilities were investigated of projection microfocus x-radiography, ultrasonic velocity and attenuation, and reflection scanning acoustic microscopy for characterizing silicon carbide specimens. Silicon carbide batches covered a range of densities and different microstructural characteristics. Room temperature, four point flexural strength tests were conducted. Fractography was used to identify types, sizes, and locations of fracture origins. Fracture toughness values were calculated from fracture strength and flaw characterization data. Detection capabilities of radiography and acoustic microscopy for fracture-causing flaws were evaluated. Applicability of ultrasonics for verifying material strength and toughness was examined.
FSW between Al alloy and Mg Alloy: the comparative study
NASA Astrophysics Data System (ADS)
Jagadeesha, C. B.
2017-04-01
It is difficult to fusion weld Al alloy to Mg alloy, so by experimental optimization procedure (EOP) optimum parameters for FSW between Al alloy and Mg alloy were determined and experiment conducted using these parameters resulted in not only sound weld but also highest strength weld for 5 mm thickness of the alloys plates. One can arrive to optimum parameters by following the EOP in case of similar and dissimilar materials FSW, such as Al alloy and Mg alloy FSW. It has observed that tensile sample having least thickness intermetallics (IMs) layer has highest strength compared to sample with larger thickness of intermetallics layer and also it has observed that weld of lesser thickness plates have strength higher than welds of larger thickness plates. It has observed that, Vickers hardness in WN i.e. on the region containing layers of IMs is considerably higher, which leads to emerge of new type of laminated composite materials. It has observed that, it is the least thickness IMs layers in the weld are responsible for higher strength of weld not the ductility of the IMs formed owing to the insertion of intermediate material in the weld. It has found that coefficient of friction is =0.25, in case of bead on plate welding of Mg alloy.
NASA Technical Reports Server (NTRS)
Lange, R. Connor
2012-01-01
Ever since Explorer-1, the United States' first Earth satellite, was developed and launched in 1958, JPL has developed many more spacecraft, including landers and orbiters. While these spacecraft vary greatly in their missions, capabilities,and destination, they all have something in common. All of the components of these spacecraft had to be comprehensively tested. While thorough testing is important to mitigate risk, it is also a very expensive and time consuming process. Thankfully,since virtually all of the software testing procedures for SMAP are computer controlled, these procedures can be automated. Most people testing SMAP flight software (FSW) would only need to write tests that exercise specific requirements and then check the filtered results to verify everything occurred as planned. This gives developers the ability to automatically launch tests on the testbed, distill the resulting logs into only the important information, generate validation documentation, and then deliver the documentation to management. With many of the steps in FSW testing automated, developers can use their limited time more effectively and can validate SMAP FSW modules quicker and test them more rigorously. As a result of the various benefits of automating much of the testing process, management is considering this automated tools use in future FSW validation efforts.
NASA Technical Reports Server (NTRS)
Dewan, Mohammad W.; Huggett, Daniel J.; Liao, T. Warren; Wahab, Muhammad A.; Okeil, Ayman M.
2015-01-01
Friction-stir-welding (FSW) is a solid-state joining process where joint properties are dependent on welding process parameters. In the current study three critical process parameters including spindle speed (??), plunge force (????), and welding speed (??) are considered key factors in the determination of ultimate tensile strength (UTS) of welded aluminum alloy joints. A total of 73 weld schedules were welded and tensile properties were subsequently obtained experimentally. It is observed that all three process parameters have direct influence on UTS of the welded joints. Utilizing experimental data, an optimized adaptive neuro-fuzzy inference system (ANFIS) model has been developed to predict UTS of FSW joints. A total of 1200 models were developed by varying the number of membership functions (MFs), type of MFs, and combination of four input variables (??,??,????,??????) utilizing a MATLAB platform. Note EFI denotes an empirical force index derived from the three process parameters. For comparison, optimized artificial neural network (ANN) models were also developed to predict UTS from FSW process parameters. By comparing ANFIS and ANN predicted results, it was found that optimized ANFIS models provide better results than ANN. This newly developed best ANFIS model could be utilized for prediction of UTS of FSW joints.
Wear-Induced Changes in FSW Tool Pin Profile: Effect of Process Parameters
NASA Astrophysics Data System (ADS)
Sahlot, Pankaj; Jha, Kaushal; Dey, G. K.; Arora, Amit
2018-06-01
Friction stir welding (FSW) of high melting point metallic (HMPM) materials has limited application due to tool wear and relatively short tool life. Tool wear changes the profile of the tool pin and adversely affects weld properties. A quantitative understanding of tool wear and tool pin profile is crucial to develop the process for joining of HMPM materials. Here we present a quantitative wear study of H13 steel tool pin profile for FSW of CuCrZr alloy. The tool pin profile is analyzed at multiple traverse distances for welding with various tool rotational and traverse speeds. The results indicate that measured wear depth is small near the pin root and significantly increases towards the tip. Near the pin tip, wear depth increases with increase in tool rotational speed. However, change in wear depth near the pin root is minimal. Wear depth also increases with decrease in tool traverse speeds. Tool pin wear from the bottom results in pin length reduction, which is greater for higher tool rotational speeds, and longer traverse distances. The pin profile changes due to wear and result in root defect for long traverse distance. This quantitative understanding of tool wear would be helpful to estimate tool wear, optimize process parameters, and tool pin shape during FSW of HMPM materials.
MRI compatibility of robot actuation techniques--a comparative study.
Fischer, Gregory S; Krieger, Axel; Iordachita, Iulian; Csoma, Csaba; Whitcomb, Louis L; Gabor, Fichtinger
2008-01-01
This paper reports an experimental evaluation of the following three different MRI-compatible actuators: a Shinsei ultrasonic motor a Nanomotion ultrasonic motor and a pneumatic cylinder actuator. We report the results of a study comparing the effect of these actuators on the signal to noise ratio (SNR) of MRJ images under a variety of experimental conditions. Evaluation was performed with the controller inside and outside the scanner room and with both 1.5T and 3T MRI scanners. Pneumatic cylinders function with no loss of SNR with controller both inside and outside of the scanner room. The Nanomotion motor performs with moderate loss of SNR when moving during imaging. The Shinsei is unsuitable for motion during imaging. All may be used when motion is appropriately interleaved with imaging cycles.
Three-Dimensional Model of the Scatterer Distribution in Cirrhotic Liver
NASA Astrophysics Data System (ADS)
Yamaguchi, Tadashi; Nakamura, Keigo; Hachiya, Hiroyuki
2003-05-01
Ultrasonic B-mode images are affected by changes in scatterer distribution. It is hard to estimate the relationship between the ultrasonic image and the tissue structure quantitatively because we cannot observe the continuous stages of liver cirrhosis tissue clinically, particularly the beginning stage. In this paper, we propose a three-dimensional modeling method of scatterer distribution for normal and cirrhotic livers to confirm the influence of the change in the form of scatterer distribution on echo information. The algorithm of the method includes parameters which determine the expansion of nodules and fibers. Using the B-mode images which are obtained from these scatterer distributions, we analyze the relationship between the changes in the form of biological tissue and the changes in the B-mode images during progressive liver cirrhosis.
Ultrasonic-assisted dyeing of Nylon-6 nanofibers.
Jatoi, Abdul Wahab; Ahmed, Farooq; Khatri, Muzamil; Tanwari, Anwaruddin; Khatri, Zeeshan; Lee, Hoik; Kim, Ick Soo
2017-11-01
We first time report ultrasonic dyeing of the Nylon 6 nanofibers with two disperse dyes CI Disperse blue 56 and CI Disperse Red 167:1 by utilising ultrasonic energy during dyeing process. The Nylon 6 nanofibers were fabricated via electrospinning and dyed via batchwise method with and without sonication. Results revealed that ultrasonic dyeing produce higher color yield (K/S values) and substantially reduces dyeing time from 60min for conventional dyeing to 30min can be attributed to breakage of dye aggregate, transient cavitation near nanofiber surface and mass transfer within/between nanofibers. Color fastness results exhibited good to very good dye fixation. SEM images exhibit insignificant effect of sonication on morphology of the nanofibers. Our research results demonstrate ultrasonic dyeing as a better dyeing technique for Nylon 6 nanofibers with higher color yield and substantially reduced dyeing time. Copyright © 2017 Elsevier B.V. All rights reserved.
A Portable Ultrasonic Nondestructive Inspection System for Metal Matrix Composite Track Shoes
NASA Astrophysics Data System (ADS)
Mi, Bao; Zhao, Xiaoliang; Qian, Tao; Stevenson, Mark; Kwan, Chiman; Owens, Steven E.; Royer, Roger L.; Tittmann, Bernhard R.; Raju, Basavaraju B.
2007-03-01
Cast aluminum track shoes reinforced with metal matrix composite (MMC) inserts at heavy loading areas such as center splines and sprocket windows are light in weight, and can resist high temperature and wear. Various defects such as disbonds at the insert-substrate interface, cracks and porosity in the MMC layer, etc. can be introduced during the manufacturing process and/or in service. This paper presents a portable ultrasonic system to automatically inspect tank track shoes for disbond. Ultrasonic pulse/echo inspection has shown good reliability for disbond detection. A prototype sensor array fixture has been designed and fabricated to prove the feasibility. Good agreements between the sensor fixture results and ultrasonic C-scan images were obtained.
Nanoscale Visualization of Elastic Inhomogeneities at TiN Coatings Using Ultrasonic Force Microscopy
NASA Astrophysics Data System (ADS)
Hidalgo, J. A.; Montero-Ocampo, C.; Cuberes, M. T.
2009-12-01
Ultrasonic force microscopy has been applied to the characterization of titanium nitride coatings deposited by physical vapor deposition dc magnetron sputtering on stainless steel substrates. The titanium nitride layers exhibit a rich variety of elastic contrast in the ultrasonic force microscopy images. Nanoscale inhomogeneities in stiffness on the titanium nitride films have been attributed to softer substoichiometric titanium nitride species and/or trapped subsurface gas. The results show that increasing the sputtering power at the Ti cathode increases the elastic homogeneity of the titanium nitride layers on the nanometer scale. Ultrasonic force microscopy elastic mapping on titanium nitride layers demonstrates the capability of the technique to provide information of high value for the engineering of improved coatings.
Ultrasonic control of ceramic membrane fouling by particles: effect of ultrasonic factors.
Chen, Dong; Weavers, Linda K; Walker, Harold W
2006-07-01
Ultrasound at 20 kHz was applied to a cross-flow ultrafiltration system with gamma-alumina membranes in the presence of colloidal silica particles to systematically investigate how ultrasonic factors affect membrane cleaning. Based on imaging of the ultrasonic cavitation region, optimal cleaning occurred when the membrane was outside but close to the cavitation region. Increasing the filtration pressure increased the compressive forces driving cavitation collapse and resulted in fewer cavitation bubbles absorbing and scattering sound waves and increasing sound wave penetration. However, an increased filtration pressure also resulted in greater permeation drag, and subsequently less improvement in permeate flux compared to low filtration pressure. Finally, pulsed ultrasound with short pulse intervals resulted in permeate flux improvement close to that of continuous sonication.
Third COS FUV Lifetime Position: FUV Target Acquisition Parameter Update {LENA3}
NASA Astrophysics Data System (ADS)
Penton, Steven
2013-10-01
Verify the ability of the Cycle 22 COS FSW to place an isolated point source at the center of the PSA, using FUV dispersed light target acquisition (TA) from the object and all three FUV gratings at the Third Lifetime Position (LP3). This program is modeled from the activity summary of LENA3.This program should be executed after the LP3 HV, XD spectral positions, aperture mechanism position, and focus are determined and updated. In addition, initial estimates of the LIFETIME=ALTERNATE TA FSW parameters and subarrays should be updated prior to execution of this program. After Visit 01, the subarrays will be updated. After Visit 2, the FUV WCA-to-PSA offsets will be updateded. Prior to Visit 6, LV56 will be installed will include new values for the LP3 FUV plate scales. VISIT 6 exposures use the default lifetime position (LP3).NUV imaging TAs have previously been used to determine the correct locations for FUV spectra. We follow the same procedure here.Note that the ETC runs here were made using ETC22.2 and are therefore valid for Mach 2014. Some TDS drop will likely have occured before these visits execute, but we have plenty of count to go what we need to do in this program.
Ultrasonic Evaluation and Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, Susan L.; Anderson, Michael T.; Diaz, Aaron A.
2015-10-01
Ultrasonic evaluation of materials for material characterization and flaw detection is as simple as manually moving a single-element probe across a speci-men and looking at an oscilloscope display in real time or as complex as automatically (under computer control) scanning a phased-array probe across a specimen and collecting encoded data for immediate or off-line data analyses. The reliability of the results in the second technique is greatly increased because of a higher density of measurements per scanned area and measurements that can be more precisely related to the specimen geometry. This chapter will briefly discuss applications of the collection ofmore » spatially encoded data and focus primarily on the off-line analyses in the form of data imaging. Pacific Northwest National Laboratory (PNNL) has been involved with as-sessing and advancing the reliability of inservice inspections of nuclear power plant components for over 35 years. Modern ultrasonic imaging techniques such as the synthetic aperture focusing technique (SAFT), phased-array (PA) technolo-gy and sound field mapping have undergone considerable improvements to effec-tively assess and better understand material constraints.« less
Winterroth, Frank; Kato, Hiroko; Kuo, Shiuhyang; Feinberg, Stephen E; Hollister, Scott J; Fowlkes, J Brian; Hollman, Kyle W
2014-09-01
This study uses high-resolution ultrasound to examine the growth and development of engineered oral mucosal tissues manufactured under aseptic conditions. The specimens are a commercially available natural tissue scaffold, AlloDerm, and oral keratinocytes seeded onto AlloDerm to form an ex vivo-produced oral mucosal equivalent (EVPOME) suitable for intra-oral grafting. The seeded cells produce a keratinized protective upper layer that smooths out any remaining surface irregularities on the underlying AlloDerm. Two-dimensional acoustic imaging of unseeded AlloDerm and developing EVPOMEs was performed on each day of their growth and development, each tissue specimen being imaged under aseptic conditions (total time from seeding to maturation: 11 d). Ultrasonic monitoring offers us the ability to determine the constituents of the EVPOME that are responsible for changes in its mechanical behavior during the manufacturing process. Ultrasonic monitoring affords us an opportunity to non-invasively assess, in real time, tissue-engineered constructs before release for use in patient care. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Roth, Don J.; Farmer, Donald A.
1998-01-01
Abrasive cut-off wheels are at times unintentionally manufactured with nonuniformity that is difficult to identify and sufficiently characterize without time-consuming, destructive examination. One particular nonuniformity is a density variation condition occurring around the wheel circumference or along the radius, or both. This density variation, depending on its severity, can cause wheel warpage and wheel vibration resulting in unacceptable performance and perhaps premature failure of the wheel. Conventional nondestructive evaluation methods such as ultrasonic c-scan imaging and film radiography are inaccurate in their attempts at characterizing the density variation because a superimposing thickness variation exists as well in the wheel. In this article, the single transducer thickness-independent ultrasonic imaging method, developed specifically to allow more accurate characterization of aerospace components, is shown to precisely characterize the extent of the density variation in a cut-off wheel having a superimposing thickness variation. The method thereby has potential as an effective quality control tool in the abrasives industry for the wheel manufacturer.
A feasiblity study of an ultrasonic test phantom arm
NASA Astrophysics Data System (ADS)
Schneider, Philip
This thesis is a feasibility study for the creation of a test phantom that replicates the physiological features, from an acoustic and mechanical standpoint, of that of a human arm. Physiological feature set includes; Heart, Arteries, Veins, Bone, Muscle, Fat, Skin, and Dermotographic Features (finger prints). Mechanical Aspects include, vascular compression and distention, elasticity of tissue layers, mechanics of human heart. The end goal of which to have a working understanding of each component in order to create a controllable, real time, physiologically accurate, test phantom for a wide range of ultrasonic based applications. These applications can range from devices like wearable technologies to medical training, to biometric "Liveness" detection methods. The proposed phantom would allow for a number of natural bodily functions to be measured including but not limited to vascular mapping, blood pressure, heart rate, subdermal imaging, and general ultrasonic imaging.
Controlling dispersion of graphene nanoplatelets in aqueous solution by ultrasonic technique
NASA Astrophysics Data System (ADS)
Wang, Baomin; Jiang, Ruishuang; Song, Wanzeng; Liu, Hui
2017-08-01
The homogenous graphene nanoplatelets (GNP) suspension had been prepared through ultrasonic exfoliation in the presence of methylcellulose (MC) as dispersant. The influence of different sonication times on dispersing of aqueous GNP suspension was monitored by UV-Vis absorbance, sedimentation test, optical microscope and transmission electron microscope (TEM). The study of UV-Vis absorbance verifies that the minimum sonication time to break the 0.1 g/L concentration of bundled GNPs is 20 min; furthermore, the GNP suspension achieved the best dispersion, when sonication time increased up to 80 min. From optical microscope images of GNPs, the agglomeration of GNPs was broken by enough sonication energy, and the distribution of GNPs particles became more uniform. The dispersing mechanism had been discussed and simulated by HRTEM image. The bundled GNPs were exfoliated by cavitation effect of ultrasonic irradiation, meanwhile, the dispersant adsorbed on the surface of GNPs prevented re-entanglement by forming steric hindrance.
Dispersion curve estimation via a spatial covariance method with ultrasonic wavefield imaging.
Chong, See Yenn; Todd, Michael D
2018-05-01
Numerous Lamb wave dispersion curve estimation methods have been developed to support damage detection and localization strategies in non-destructive evaluation/structural health monitoring (NDE/SHM) applications. In this paper, the covariance matrix is used to extract features from an ultrasonic wavefield imaging (UWI) scan in order to estimate the phase and group velocities of S0 and A0 modes. A laser ultrasonic interrogation method based on a Q-switched laser scanning system was used to interrogate full-field ultrasonic signals in a 2-mm aluminum plate at five different frequencies. These full-field ultrasonic signals were processed in three-dimensional space-time domain. Then, the time-dependent covariance matrices of the UWI were obtained based on the vector variables in Cartesian and polar coordinate spaces for all time samples. A spatial covariance map was constructed to show spatial correlations within the full wavefield. It was observed that the variances may be used as a feature for S0 and A0 mode properties. The phase velocity and the group velocity were found using a variance map and an enveloped variance map, respectively, at five different frequencies. This facilitated the estimation of Lamb wave dispersion curves. The estimated dispersion curves of the S0 and A0 modes showed good agreement with the theoretical dispersion curves. Copyright © 2018 Elsevier B.V. All rights reserved.
Penetration of sub-micron particles into dentinal tubules using ultrasonic cavitation.
Vyas, N; Sammons, R L; Pikramenou, Z; Palin, W M; Dehghani, H; Walmsley, A D
2017-01-01
Functionalised silica sub-micron particles are being investigated as a method of delivering antimicrobials and remineralisation agents into dentinal tubules. However, their methods of application are not optimised, resulting in shallow penetration and aggregation. The aim of this study is to investigate the impact of cavitation occurring around ultrasonic scalers for enhancing particle penetration into dentinal tubules. Dentine slices were prepared from premolar teeth. Silica sub-micron particles were prepared in water or acetone. Cavitation from an ultrasonic scaler (Satelec P5 Newtron, Acteon, France) was applied to dentine slices immersed inside the sub-micron particle solutions. Samples were imaged with scanning electron microscopy (SEM) to assess tubule occlusion and particle penetration. Qualitative observations of SEM images showed some tubule occlusion. The particles could penetrate inside the tubules up to 60μm when there was no cavitation and up to ∼180μm when there was cavitation. The cavitation bubbles produced from an ultrasonic scaler may be used to deliver sub-micron particles into dentine. This method has the potential to deliver such particles deeper into the dentinal tubules. Cavitation from a clinical ultrasonic scaler may enhance penetration of sub-micron particles into dentinal tubules. This can aid in the development of novel methods for delivering therapeutic clinical materials for hypersensitivity relief and treatment of dentinal caries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Social support and recovery among Mexican female sex workers who inject drugs
Hiller, Sarah; Syvertsen, Jennifer; Lozada, Remedios; Ojeda, Victoria D.
2013-01-01
This qualitative study describes social support that female sex workers who inject drugs (FSW-IDUs) receive and recovery efforts in the context of relationships with family and intimate partners. We conducted thematic analysis of in-depth interviews with 47 FSW-IDUs enrolled in an intervention study to reduce injection/sexual risk behaviors in Tijuana, Mexico. FSW-IDUs received instrumental and emotional social support, which positively and negatively influenced recovery efforts. Participants reported how some intimate partners provided conflicting positive and negative support during recovery attempts. Problematic support (i.e., well-intended support with unintended consequences) occurred in strained family relationships, limiting the positive effects of support. Mexican drug treatment programs should consider addressing social support in recovery curricula through evidence-based interventions that engage intimate partners, children and family to better reflect socio-cultural and contextual determinants of substance abuse. PMID:23375570
Friction Stir Welding of ODS and RAFM Steels
Yu, Zhenzhen; Feng, Zhili; Hoelzer, David; ...
2015-09-14
Advanced structural materials such as oxide dispersion strengthened steels and reduced-activation ferritic/martensitic steels are desired in fusion reactors as primary candidate materials for first wall and blanket structures, due to their excellent radiation and high-temperature creep resistance. However, their poor fusion weldability has been the major technical challenge limiting practical applications. For this reason, solid-state friction stir welding (FSW) has been considered for such applications. In this paper, the effect of FSW parameters on joining similar and dissimilar advanced structural steels was investigated. Scanning electron microscopy and electron backscatter diffraction methods were used to reveal the effects of FSW onmore » grain size, micro-texture distribution, and phase stability. Hardness mapping was performed to evaluate mechanical properties. Finally, post weld heat treatment was also performed to tailor the microstructure in the welds in order to match the weld zone mechanical properties to the base material.« less
Social support and recovery among Mexican female sex workers who inject drugs.
Hiller, Sarah P; Syvertsen, Jennifer L; Lozada, Remedios; Ojeda, Victoria D
2013-07-01
This qualitative study describes social support that female sex workers who inject drugs (FSW-IDUs) receive and recovery efforts in the context of relationships with family and intimate partners. We conducted thematic analysis of in-depth interviews with 47 FSW-IDUs enrolled in an intervention study to reduce injection/sexual risk behaviors in Tijuana, Mexico. FSW-IDUs received instrumental and emotional social support, which positively and negatively influenced recovery efforts. Participants reported how some intimate partners provided conflicting positive and negative support during recovery attempts. Problematic support (i.e., well-intended support with unintended consequences) occurred in strained family relationships, limiting the positive effects of support. Mexican drug treatment programs should consider addressing social support in recovery curricula through evidence-based interventions that engage intimate partners, children and family to better reflect socio-cultural and contextual determinants of substance abuse. Copyright © 2013 Elsevier Inc. All rights reserved.
Thermal Management in Friction-Stir Welding of Precipitation-Hardened Aluminum Alloys
NASA Astrophysics Data System (ADS)
Upadhyay, Piyush; Reynolds, Anthony P.
2015-05-01
Process design and implementation in friction-stir welding (FSW) is mostly dependent on empirical information. Basic science of FSW and processing can only be complete when fundamental interrelationships between the process control parameters and response variables and the resulting weld microstructure and properties are established to a reasonable extent. It is known that primary process control parameters such as tool rotation, translation rates, and forge axis force have complicated and interactive relationships to process-response variables such as peak temperature and time at temperature. Of primary influence on the other process-response parameters are temperature and its gradient in the deformation and heat-affected zones. Through a review of pertinent works in the literature and results from boundary condition experiments performed in precipitation-hardening aluminum alloys, this article partially elucidates the nature and effects of temperature transients caused by variation of thermal boundaries in FSW.
Menon, Sonia; Broeck, Davy Vanden; Rossi, Rodolfo; Ogbe, Emilomo; Harmon, Stacy; Mabeya, Hillary
2016-12-01
Infection with and persistence of high-risk human papillomavirus (HR HPV) are the strongest risk factors for cervical cancer. Little is known about the prevalence and role of concurrent sexually transmitted infections (STIs) found in HPV-infected female sex workers (FSW) in Africa. This study purports to test our a priori hypotheses that STIs are associated with genotypes pertaining to the α-group species 9. The objectives were to determine the prevalence of bacterial vaginosis (BV), Trichomonas vaginalis, and Candida spp in FSW, the association between these STIs and the prevalence of any potential HR and HR HPV genotypes in FSWs. A cross-sectional study design of 616 FSW from Western Kenya aged between 18 and 61 years during 2009-2015 using a peer recruitment sampling strategy. Inclusion criteria for the study entailed female sex and >18 years of age and having engaged in transactional sex in exchange for money, goods, services, or drugs in the last 3 months. Women were excluded if they were pregnant, <18 years of age, had a history of cervical dysplasia or cancer, had current abnormal bleeding, or had a hysterectomy. Of the FSW, 33.3% had HIV and 57.7% harbored a potential HR and HR HPV genotype. The 2 most prevalent potential HR and HR genotypes were HPV 16 (16.10%) and HPV 59 (12.20%). BV was the most common infection (48.3%), followed by Trichomonas vaginalis (31.4%) and Candida spp (19.9%). A multivariate regression revealed significant associations with both α-group 9 and 6; BV and HPV 58 (adjusted odds ratio [aOR] = 2.3; 95% CI, 1.0-5.2; P = 0.05), Trichomonas vaginalis and HPV 31 and HPV 35 (aOR = 2.0; 95% CI, 1.0-3.8; P = 0.04 and aOR = 1.8; 95% CI, 1.0-3.3, P = 0.05 respectively); and between Candida spp and HPV 53 (aOR = 2.0; 95% CI, 1.1-4.0; P = 0.03) and 16 (aOR = 1.9; 95% CI, 1.1-3.3; P = 0.03). Snowball sampling may have inadvertently excluded FSW less likely to benefit from a social network. Significant associations between BV and HPV 58 and between Candida spp and HPV 16 and 53 suggest the need for sexually transmitted disease management within a cervical cancer prevention program. The probable synergistic effects of the vaginal microbiota should be elucidated, especially within this vulnerable population. Given the potential for FSW to transmit STIs, robust epidemiologic sampling methods are urgently required that account for the heterogeneity of the FSW population. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.
Microwave-excited ultrasound and thermoacoustic dual imaging
NASA Astrophysics Data System (ADS)
Ding, Wenzheng; Ji, Zhong; Xing, Da
2017-05-01
We designed a microwave-excited ultrasound (MUI) and thermoacoustic dual imaging system. Under the pulsed microwave excitation, the piezoelectric transducer used for thermoacoustic signal detection will also emit a highly directional ultrasonic beam based on the inverse piezoelectric effect. With this beam, the ultrasonic transmitter circuitry of the traditional ultrasound imaging (TUI) system can be replaced by a microwave source. In other words, TUI can be fully integrated into the thermoacoustic imaging system by sharing the microwave excitation source and the transducer. Moreover, the signals of the two imaging modalities do not interfere with each other due to the existence of the sound path difference, so that MUI can be performed simultaneously with microwave-induced thermoacoustic imaging. In the study, the performance characteristics and imaging capabilities of this hybrid system are demonstrated. The results indicate that our design provides one easy method for low-cost platform integration and has the potential to offer a clinically useful dual-modality tool for the detection of accurate diseases.
Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces
Zhu, Xuan; Li, Xiaoshi; Chen, Zeyu; Chen, Yimu; Lei, Yusheng; Li, Yang; Nomoto, Akihiro; Zhou, Qifa; di Scalea, Francesco Lanza
2018-01-01
Ultrasonic imaging has been implemented as a powerful tool for noninvasive subsurface inspections of both structural and biological media. Current ultrasound probes are rigid and bulky and cannot readily image through nonplanar three-dimensional (3D) surfaces. However, imaging through these complicated surfaces is vital because stress concentrations at geometrical discontinuities render these surfaces highly prone to defects. This study reports a stretchable ultrasound probe that can conform to and detect nonplanar complex surfaces. The probe consists of a 10 × 10 array of piezoelectric transducers that exploit an “island-bridge” layout with multilayer electrodes, encapsulated by thin and compliant silicone elastomers. The stretchable probe shows excellent electromechanical coupling, minimal cross-talk, and more than 50% stretchability. Its performance is demonstrated by reconstructing defects in 3D space with high spatial resolution through flat, concave, and convex surfaces. The results hold great implications for applications of ultrasound that require imaging through complex surfaces. PMID:29740603
Photo-induced ultrasound microscopy for photo-acoustic imaging of non-absorbing specimens
NASA Astrophysics Data System (ADS)
Tcarenkova, Elena; Koho, Sami V.; Hänninen, Pekka E.
2017-08-01
Photo-Acoustic Microscopy (PAM) has raised high interest in in-vivo imaging due to its ability to preserve the near-diffraction limited spatial resolution of optical microscopes, whilst extending the penetration depth to the mm-range. Another advantage of PAM is that it is a label-free technique - any substance that absorbs PAM excitation laser light can be viewed. However, not all sample structures desired to be observed absorb sufficiently to provide contrast for imaging. This work describes a novel imaging method that makes it possible to visualize optically transparent samples that lack intrinsic photo-acoustic contrast, without the addition of contrast agents. A thin, strongly light absorbing layer next to sample is used to generate a strong ultrasonic signal. This signal, when recorded from opposite side, contains ultrasonic transmission information of the sample and thus the method can be used to obtain an ultrasound transmission image on any PAM.
Kothapalli, Sri-Rajasekhar; Ma, Te-Jen; Vaithilingam, Srikant; Oralkan, Ömer
2014-01-01
In this paper, we demonstrate 3-D photoacoustic imaging (PAI) of light absorbing objects embedded as deep as 5 cm inside strong optically scattering phantoms using a miniaturized (4 mm × 4 mm × 500 µm), 2-D capacitive micromachined ultrasonic transducer (CMUT) array of 16 × 16 elements with a center frequency of 5.5 MHz. Two-dimensional tomographic images and 3-D volumetric images of the objects placed at different depths are presented. In addition, we studied the sensitivity of CMUT-based PAI to the concentration of indocyanine green dye at 5 cm depth inside the phantom. Under optimized experimental conditions, the objects at 5 cm depth can be imaged with SNR of about 35 dB and a spatial resolution of approximately 500 µm. Results demonstrate that CMUTs with integrated front-end amplifier circuits are an attractive choice for achieving relatively high depth sensitivity for PAI. PMID:22249594
NASA Astrophysics Data System (ADS)
Saint-Michel, Brice; Bodiguel, Hugues; Meeker, Steven; Manneville, Sébastien
2017-07-01
We extend a previously developed ultrafast ultrasonic technique [T. Gallot et al., Rev. Sci. Instrum. 84, 045107 (2013), 10.1063/1.4801462] to concentration-field measurements in non-Brownian particle suspensions under shear. The technique provides access to time-resolved concentration maps within the gap of a Taylor-Couette cell simultaneously to local velocity measurements and standard rheological characterization. Benchmark experiments in homogeneous particle suspensions are used to calibrate the system. We then image heterogeneous concentration fields that result from centrifugation effects, from the classical Taylor-Couette instability, and from sedimentation or shear-induced resuspension.
Risk factors for HIV infection among female sex workers in Bangui, Central African Republic
Diemer, Henri Saint-Calvaire; Grésenguet, Gérard; Brücker, Gilles; Belec, Laurent
2017-01-01
Objective The aims of the study were i) to categorize female sex workers (FSW) according to socio-anthropologic criteria in Bangui; ii) to examine the association between a selection of demographic and risk variables with the different categories of female sex work as outcome, and iii) to investigate factors associated with HIV status. Methods A cross-sectional questionnaire survey was conducted to describe the spectrum of commercial sex work in Bangui among 345 sexually active women. After collection of social and behavioral characteristics, each woman received a physical examination and a blood sample was taken for biological analyses, including HIV testing. The relationships between sociodemographic characteristics, behavioral variables involved in high risk for HIV as well as biological results were investigated by bivariate analysis in relationship with FSW categories as main outcomes, and by bivariate analysis followed by multivariate logistic regression analysis in relationship with HIV as the main outcome. The strength of statistical associations was measured by crude and adjusted Odds ratios (OR) and their 95% confidence intervals. Results The typology of FSW comprised six different categories. Two groups were the “official” professional FSW primarily classified according to their locations of work [i) “kata“(18.55%) representing women working in poor neighborhoods of Bangui; ii) “pupulenge” (13.91%) working in hotels and night clubs to seek white men]. Four groups were “clandestine” nonprofessional FSW classified according to their reported main activity [i) “market and street vendors” (20.86%); ii) “schoolgirls or students” (19.13%) involved in occasional transactional sex (during holidays); iii) “housewives or unemployed women” (15.65%); iv) “civil servants” (11.88%) working as soldiers or in the public sector]. The overall prevalence of HIV-1 was 19.12% (66/345). HIV varied according to FSW categories. Thus, among professional FSW, the HIV prevalence was 6-fold higher in "kata" than "pupulenge" (39.13% versus 6.30%; P = 0.001). Among nonprofessional FSW, the "vendors" showed the highest HIV prevalence (31.91%), which was higher than in "students" (6.10%; P = 0.001), "civil servants" (9.83%; P = 0.005), and "housewives" (13.00%; P = 0.01). In bivariate analysis, the following variables showed statistically significant association with risk for HIV infection: nationality; age of first sexual intercourse; self-assessment of HIV risk; knowledge of HIV status; anal sex practice with last clients; irregular condom use in last week; consumption of alcohol; other psycho-active substances; past history of STIs; HBs Ag; HSV-2 and bacterial vaginosis. However, the variable “sex workers categories” dichotomized into professional versus nonprofessional FSW was no longer associated with HIV. In multivariate logistical regression analysis, HIV infection was strongly associated with nationality (15.65% versus 3.77%) [adjusted OR (aOR) 3.39: 95% CI:1.25–9.16, P<0.05]; age of first sexual intercourse (21.10% versus 14.00%) (aOR 2.13: 95% CI: 1.03–4.39, P<0.05); anal sex practice with last clients (43.40% versus 11.50%) (aOR 4.31: 95% CI:2.28–8.33, P<0.001); irregular condom use in past week (33.50% versus 3.00%) (aOR 5.49: 95% CI:1.89–15.98, P<0.001); alcohol consumption before sex (34.70% versus 7.80%) (aOR 2.69: 95% CI:1.22–4.96, P<0.05); past history of STIs (41.00% versus 10.80%) (aOR 2.46: 95% CI:1.22–4.97, P<0.05) and bacterial vaginosis (29.80% versus 4.29%) (aOR 6.36: 95% CI: 2.30–17.72, P<0.001). Conclusion Our observations highlight the high level of vulnerability for HIV acquisition of both poor professional “kata” and nonprofessional “street vendor” FSW categories. These categories should be particularly taken into account when designing specific prevention programs for STIs/HIV control purposes. PMID:29108022
Ultrasound-modulated optical tomography with intense acoustic bursts.
Zemp, Roger J; Kim, Chulhong; Wang, Lihong V
2007-04-01
Ultrasound-modulated optical tomography (UOT) detects ultrasonically modulated light to spatially localize multiply scattered photons in turbid media with the ultimate goal of imaging the optical properties in living subjects. A principal challenge of the technique is weak modulated signal strength. We discuss ways to push the limits of signal enhancement with intense acoustic bursts while conforming to optical and ultrasonic safety standards. A CCD-based speckle-contrast detection scheme is used to detect acoustically modulated light by measuring changes in speckle statistics between ultrasound-on and ultrasound-off states. The CCD image capture is synchronized with the ultrasound burst pulse sequence. Transient acoustic radiation force, a consequence of bursts, is seen to produce slight signal enhancement over pure ultrasonic-modulation mechanisms for bursts and CCD exposure times of the order of milliseconds. However, acoustic radiation-force-induced shear waves are launched away from the acoustic sample volume, which degrade UOT spatial resolution. By time gating the CCD camera to capture modulated light before radiation force has an opportunity to accumulate significant tissue displacement, we reduce the effects of shear-wave image degradation, while enabling very high signal-to-noise ratios. Additionally, we maintain high-resolution images representative of optical and not mechanical contrast. Signal-to-noise levels are sufficiently high so as to enable acquisition of 2D images of phantoms with one acoustic burst per pixel.
High Resolution Ultrasonic Method for 3D Fingerprint Representation in Biometrics
NASA Astrophysics Data System (ADS)
Maev, R. Gr.; Bakulin, E. Y.; Maeva, E. Y.; Severin, F. M.
Biometrics is an important field which studies different possible ways of personal identification. Among a number of existing biometric techniques fingerprint recognition stands alone - because very large database of fingerprints has already been acquired. Also, fingerprints are an important evidence that can be collected at a crime scene. Therefore, of all automated biometric techniques, especially in the field of law enforcement, fingerprint identification seems to be the most promising. Ultrasonic method of fingerprint imaging was originally introduced over a decade as the mapping of the reflection coefficient at the interface between the finger and a covering plate and has shown very good reliability and free from imperfections of previous two methods. This work introduces a newer development of the ultrasonic fingerprint imaging, focusing on the imaging of the internal structures of fingerprints (including sweat pores) with raw acoustic resolution of about 500 dpi (0.05 mm) using a scanning acoustic microscope to obtain images and acoustic data in the form of 3D data array. C-scans from different depths inside the fingerprint area of fingers of several volunteers were obtained and showed good contrast of ridges-and-valleys patterns and practically exact correspondence to the standard ink-and-paper prints of the same areas. Important feature reveled on the acoustic images was the clear appearance of the sweat pores, which could provide additional means of identification.
Development of Acoustic Model-Based Iterative Reconstruction Technique for Thick-Concrete Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almansouri, Hani; Clayton, Dwight A; Kisner, Roger A
Ultrasound signals have been used extensively for non-destructive evaluation (NDE). However, typical reconstruction techniques, such as the synthetic aperture focusing technique (SAFT), are limited to quasi-homogenous thin media. New ultrasonic systems and reconstruction algorithms are in need for one-sided NDE of non-homogenous thick objects. An application example space is imaging of reinforced concrete structures for commercial nuclear power plants (NPPs). These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Another example is geothermal and oil/gas production wells. These multi-layered structuresmore » are composed of steel, cement, and several types of soil and rocks. Ultrasound systems with greater penetration range and image quality will allow for better monitoring of the well's health and prediction of high-pressure hydraulic fracturing of the rock. These application challenges need to be addressed with an integrated imaging approach, where the application, hardware, and reconstruction software are highly integrated and optimized. Therefore, we are developing an ultrasonic system with Model-Based Iterative Reconstruction (MBIR) as the image reconstruction backbone. As the first implementation of MBIR for ultrasonic signals, this paper document the first implementation of the algorithm and show reconstruction results for synthetically generated data.« less
Wang, Jian; Kang, Chunsong; Feng, Tinghua; Xue, Jiping; Shi, Kailing; Li, Tingting; Liu, Xiaofang; Wang, Yu
2013-05-01
The purpose of this study was to investigate the effects of ultrasonic instrument gain, transducer frequency, and depth on the color variety and color filling of radiofrequency ultrasonic local estimators (RULES) images which indicated specific physical representation of liquid-containing lesions in order to find the optimal settings for the clinical application of RULES in liquid-containing lesions. Changing the ultrasonic instrument gain, transducer frequency, and depth affected the color filling and color variety of 21 pathologically-confirmed liquid-containing lesion images analyzed by RULES. Blue colored fill dominated the RULES images to represent the liquid-containing lesions. A frequency of 12.5MHz led to red and green colors along the inner edges of the liquid-containing lesions. Changing the gain resulted in significantly different blue colored filling that was highest when the gain was 90 to 100. Changing the frequency also significantly changed the blue color filling, with the highest filling occurring at 12.5MHz. Changing the depth did not affect the blue color filling. The liquid components of the lesions may be identified by their characteristic manifestations in RULES, where color variety is affected by transducer frequency and blue color filling which represent liquid-containing lesions in RULES images is affected by frequency and gain. Copyright © 2012. Published by Elsevier GmbH.
NASA Astrophysics Data System (ADS)
Yalavarthy, Harshavardhan
Interactions between the rotating and advancing pin-shaped tool (terminated at one end with a circular-cylindrical shoulder) with the clamped welding-plates and the associated material and heat transport during a Friction Stir Welding (FSW) process are studied computationally using a fully-coupled thermo-mechanical finite-element analysis. To surmount potential numerical problems associated with extensive mesh distortions/entanglement, an Arbitrary Lagrangian Eulerian (ALE) formulation was used which enabled adaptive re-meshing (to ensure the continuing presence of a high-quality mesh) while allowing full tracking of the material free surfaces. To demonstrate the utility of the present computational approach, the analysis is applied to the cases of same-alloy FSW of two Aluminum-alloy grades: (a) AA5083 (a solid-solution strengthened and strain-hardened/stabilized Al-Mg-Mn alloy); and (b) AA2139 (a precipitation hardened quaternary Al-Cu-Mg-Ag alloy). Both of these alloys are currently being used in military-vehicle hull structural and armor systems. In the case of non-age-hardenable AA5083, the dominant microstructure evolution processes taking place during FSW are extensive plastic deformation and dynamic recrystallization of highly-deformed material subjected to elevated temperatures approaching the melting temperature. To account for the competition between plastic-deformation controlled strengthening and dynamic-recrystallization induced softening phenomena during the FSW process, the original Johnson-Cook strain- and strain-rate hardening and temperature-softening material strength model is modified in the present work using the available recrystallization-kinetics experimental data. In the case of AA2139, in addition to plastic deformation and dynamic recrystallization, precipitates coarsening, over-aging, dissolution and re-precipitation had to be also considered. Limited data available in the open literature pertaining to the kinetics of the aforementioned microstructure-evolution processes are used to predict variation in the material hardness and the residual stresses throughout the various FSW zones of the two alloys. The results showed that with proper modeling of the material behavior under high-temperature/severe-plastic-deformation conditions, significantly improved agreement can be attained between the computed and measured post-FSW residual-stress and material-strength distribution results. Keywords: Friction Stir Welding; AA5083; AA2139; Johnson-Cook Strength Model; Finite Element Analysis; Hardness Prediction.
Prevalence and predictors of cervicitis in female sex workers in Peru: an observational study.
Pollett, Simon; Calderon, Martha; Heitzinger, Kristen; Solari, Vicky; Montano, Silvia M; Zunt, Joseph
2013-04-30
Cervicitis is a syndrome of cervical inflammation and a common condition in female sex workers (FSW), a subpopulation vulnerable to sexually transmitted infections. Local data is essential for guiding syndromic management of cervicitis in FSW working in Peru. We sought to describe the prevalence and etiologies of cervicitis in this population. We also aimed to identify sociodemographic, behavioral and biological factors associated with cervicitis, including bacterial vaginosis (BV), a condition with a possible role in cervicitis. FSW 18 years of age or older presenting to a free public sexual health clinic in Callao-Lima, Peru were eligible for inclusion upon consent. 467 participants completed a face-to-face questionnaire and underwent genital examination. Vaginal, endocervical and blood samples were collected and tested for C. trachomatis (CT), N. gonorrhea (GC), T. vaginalis (TV), BV, HIV and Human T-Cell Lymphotropic Virus -1. Logistic regression was used to determine whether sociodemographic, behavioral, or other sexual health related characteristics were associated with the diagnosis of cervicitis. Cervicitis was detected in 99 (24.9%) of 397 FSW. The presence of cervicitis was unable to be determined in 70 participants. In women with cervicitis, CT was present in 4.6% (4/87), TV in 4.0% (4/99), GC in 0% (0/87) and no pathogen was detected on cervical microbiology in 91.9% (91/99). BV was detected on vaginal microbiology in 36.9% (31/84) of cervicitis cases. BV was more common in women with cervicitis, however this association did not reach statistical significance (aOR = 1.47 [0.87, 2.48], p = 0.15). Other STI were not associated with cervicitis. Regular clinic attendance (aOR = 0.54 [0.34, 0.87], p = 0.01) and Ecuadorian nationality (aOR = 0.31 [0.13, 0.76], p = 0.01) were associated with reduced risk of cervicitis. Cervicitis was common in FSW working Peru and was predominantly nongonococcal and non-chlamydial in etiology. Further study is warranted to clarify the role of BV and other emerging cervicitis pathogens in this population. The current Peruvian program of free health checks for FSW may be effective for reducing rates of cervicitis. The protective effect of Ecuadorian nationality prompts further study.
NASA Astrophysics Data System (ADS)
Boller, C.; Pudovikov, S.; Bulavinov, A.
2012-05-01
Austenitic stainless steel materials are widely used in a variety of industry sectors. In particular, the material is qualified to meet the design criteria of high quality in safety related applications. For example, the primary loop of the most of the nuclear power plants in the world, due to high durability and corrosion resistance, is made of this material. Certain operating conditions may cause a range of changes in the integrity of the component, and therefore require nondestructive testing at reasonable intervals. These in-service inspections are often performed using ultrasonic techniques, in particular when cracking is of specific concern. However, the coarse, dendritic grain structure of the weld material, formed during the welding process, is extreme and unpredictably anisotropic. Such structure is no longer direction-independent to the ultrasonic wave propagation; therefore, the ultrasonic beam deflects and redirects and the wave front becomes distorted. Thus, the use of conventional ultrasonic testing techniques using fixed beam angles is very limited and the application of ultrasonic Phased Array techniques becomes desirable. The "Sampling Phased Array" technique, invented and developed by Fraunhofer IZFP, allows the acquisition of time signals (A-scans) for each individual transducer element of the array along with fast image reconstruction techniques based on synthetic focusing algorithms. The reconstruction considers the sound propagation from each image pixel to the individual sensor element. For anisotropic media, where the sound beam is deflected and the sound path is not known a-priori, a novel phase adjustment technique called "Reverse Phase Matching" is implemented. By taking into account the anisotropy and inhomogeneity of the weld structure, a ray tracing algorithm for modeling the acoustic wave propagation and calculating the sound propagation time is applied. This technique can be utilized for 2D and 3D real time image reconstruction. The "Gradient Constant Descent Method" (GECDM), an iterative algorithm, is implemented, which is essential for examination of inhomogeneous anisotropic media having unknown properties (elastic constants). The Sampling Phased Array technique with Reverse Phase Matching extended by GECDM-technique determines unknown elastic constants and provides reliable and efficient quantitative flaw detection in the austenitic welds. The validation of ray-tracing algorithm and GECDM-method is performed by number of experiments on test specimens with artificial as well as natural material flaws. A mechanized system for ultrasonic testing of stainless steel and dissimilar welds is developed. The system works on both conventional and Sampling Phased Array techniques. The new frontend ultrasonic unit with optical data link allows the 3D visualization of the inspection results in real time.
Noncontact Acousto-Ultrasonics for Material Characterization
NASA Technical Reports Server (NTRS)
Kautz, Harold E.
1998-01-01
A NdYAG 1064 nm, laser pulse was employed to produce ultrasonic waves in specimens of SiC/SiC and SiC/Ti 6-4 composites which are high temperature materials of interest for aerospace applications. Air coupled transducers were used to detect and collect the signals used for acousto-ultrasonic analysis. Conditions for detecting ultrasonic decay signals were examined. The results were compared to those determined on the same specimens with contact coupling. Some non-contact measurements were made employing conventional air focused detectors. Others were performed with a more novel micromachined capacitance transducer. Concerns of the laser-in technology include potential destructiveness of the laser pulse. Repeated laser pulsing at the same location does lead to deterioration of the ultrasonic signal in some materials, but seems to recover with time. Also, unlike contact AU, the frequency regime employed is a function of laser-material interaction rather than the choice of transducers. Concerns of the air coupled-out technology include the effect of air attenuation. This imposes a practical upper limit to frequency of detection. In the case of the experimental specimens studied ultrasonic decay signals could be imaged satisfactorily.
Infrared Thermal Imaging During Ultrasonic Aspiration of Bone
NASA Astrophysics Data System (ADS)
Cotter, D. J.; Woodworth, G.; Gupta, S. V.; Manandhar, P.; Schwartz, T. H.
Ultrasonic surgical aspirator tips target removal of bone in approaches to tumors or aneurysms. Low profile angled tips provide increased visualization and safety in many high risk surgical situations that commonly were approached using a high speed rotary drill. Utilization of the ultrasonic aspirator for bone removal raised questions about relative amount of local and transmitted heat energy. In the sphenoid wing of a cadaver section, ultrasonic bone aspiration yielded lower thermal rise in precision bone removal than rotary mechanical drills, with maximum temperature of 31 °C versus 69 °C for fluted and 79 °C for diamond drill bits. Mean ultrasonic fragmentation power was about 8 Watts. Statistical studies using tenacious porcine cranium yielded mean power levels of about 4.5 Watts to 11 Watts and mean temperature of less than 41.1 °C. Excessively loading the tip yielded momentary higher power; however, mean thermal rise was less than 8 °C with bone removal starting at near body temperature of about 37 °C. Precision bone removal and thermal management were possible with conditions tested for ultrasonic bone aspiration.
Innovative Tools Advance Revolutionary Weld Technique
NASA Technical Reports Server (NTRS)
2009-01-01
The iconic, orange external tank of the space shuttle launch system not only contains the fuel used by the shuttle s main engines during liftoff but also comprises the shuttle s backbone, supporting the space shuttle orbiter and solid rocket boosters. Given the tank s structural importance and the extreme forces (7.8 million pounds of thrust load) and temperatures it encounters during launch, the welds used to construct the tank must be highly reliable. Variable polarity plasma arc welding, developed for manufacturing the external tank and later employed for building the International Space Station, was until 1994 the best process for joining the aluminum alloys used during construction. That year, Marshall Space Flight Center engineers began experimenting with a relatively new welding technique called friction stir welding (FSW), developed in 1991 by The Welding Institute, of Cambridge, England. FSW differs from traditional fusion welding in that it is a solid-state welding technique, using frictional heat and motion to join structural components without actually melting any of the material. The weld is created by a shouldered pin tool that is plunged into the seam of the materials to be joined. The tool traverses the line while rotating at high speeds, generating friction that heats and softens but does not melt the metal. (The heat produced approaches about 80 percent of the metal s melting temperature.) The pin tool s rotation crushes and stirs the plasticized metal, extruding it along the seam as the tool moves forward. The material cools and consolidates, resulting in a weld with superior mechanical properties as compared to those weld properties of fusion welds. The innovative FSW technology promises a number of attractive benefits. Because the welded materials are not melted, many of the undesirables associated with fusion welding porosity, cracking, shrinkage, and distortion of the weld are minimized or avoided. The process is more energy efficient, safe (no toxic smoke or shielding gas, liquid metal splatter, arcing, dangerous voltage, or radiation), and environmentally sound (no consumables, fumes, or noise) than fusion welding. Under computer control, an automated FSW machine can create welds with high reproducibility, improving efficiency and overall quality of manufactured materials. The process also allows for welding dissimilar metals as well as those metals considered to be "unweldable" such as the 7xxx series aluminum alloys. Its effectiveness and versatility makes FSW useful for aerospace, rail, automotive, marine, and military applications. A downside to FSW, however, is the keyhole opening left in the weld when the FSW pin tool exits the weld joint. This is a significant problem when using the FSW process to join circumferential structures such as pipes and storage containers. Furthermore, weld joints that taper in material thickness also present problems when using the conventional FSW pin tool, because the threaded pin rotating within the weld joint material is a fixed length. There must be capability for the rotating pin to both increase and decrease in length in real time while welding the tapered material. (Both circumferential and tapered thickness weldments are found in the space shuttle external tank.) Marshall engineers addressed both the keyhole and tapered material thickness problems by developing the auto-adjustable pin tool. This unique piece of equipment automatically withdraws the pin into the tool s shoulder for keyhole closeout. In addition, the auto-adjustable pin tool retracts, or shortens, the rotating pin while welding a weld joint that tapers from one thickness to a thinner thickness. This year, the impact of the Marshall innovation was recognized with an "Excellence in Technology Transfer Award" from the Federal Laboratory Consortium.
From supersonic shear wave imaging to full-field optical coherence shear wave elastography
NASA Astrophysics Data System (ADS)
Nahas, Amir; Tanter, Mickaël; Nguyen, Thu-Mai; Chassot, Jean-Marie; Fink, Mathias; Claude Boccara, A.
2013-12-01
Elasticity maps of tissue have proved to be particularly useful in providing complementary contrast to ultrasonic imaging, e.g., for cancer diagnosis at the millimeter scale. Optical coherence tomography (OCT) offers an endogenous contrast based on singly backscattered optical waves. Adding complementary contrast to OCT images by recording elasticity maps could also be valuable in improving OCT-based diagnosis at the microscopic scale. Static elastography has been successfully coupled with full-field OCT (FF-OCT) in order to realize both micrometer-scale sectioning and elasticity maps. Nevertheless, static elastography presents a number of drawbacks, mainly when stiffness quantification is required. Here, we describe the combination of two methods: transient elastography, based on speed measurements of shear waves induced by ultrasonic radiation forces, and FF-OCT, an en face OCT approach using an incoherent light source. The use of an ultrafast ultrasonic scanner and an ultrafast camera working at 10,000 to 30,000 images/s made it possible to follow shear wave propagation with both modalities. As expected, FF-OCT is found to be much more sensitive than ultrafast ultrasound to tiny shear vibrations (a few nanometers and micrometers, respectively). Stiffness assessed in gel phantoms and an ex vivo rat brain by FF-OCT is found to be in good agreement with ultrasound shear wave elastography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Xiaoxiao; Tian, Jingxuan; Wen, Weijia, E-mail: phwen@ust.hk
2016-04-18
We report a metasurface for focusing reflected ultrasonic waves over a wide frequency band of 0.45–0.55 MHz. The broadband focusing effect of the reflective metasurface is studied numerically and then confirmed experimentally using near-field scanning techniques. The focusing mechanism can be attributed to the hyperboloidal reflection phase profile imposed by different depths of concentric grooves on the metasurface. In particular, the focal lengths of the reflective metasurface are extracted from simulations and experiments, and both exhibit good linear dependence on frequency over the considered frequency band. The proposed broadband reflective metasurface with tunable focal length has potential applications in the broadmore » field of ultrasonics, such as ultrasonic tomographic imaging, high intensity focused ultrasound treatment, etc.« less
NASA Technical Reports Server (NTRS)
Miller, James G.
1993-01-01
In this Progress Report, we describe our current research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the characterization of stitched composite materials and bonded aluminum plate specimens. One purpose of this investigation is to identify and characterize specific features of polar backscatter interrogation which enhance the ability of ultrasound to detect flaws in a stitched composite laminate. Another focus is to explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize bonded aluminum lap joints. As an approach to implementing quantitative ultrasonic inspection methods to both of these materials, we focus on the physics that underlies the detection of flaws in such materials.
Full-Field Strain Behavior of Friction Stir-Welded Titanium Alloy
2008-01-01
and slag formed on the upper weld surface by the FSW process and the remnant laser weld bead on the underside of the FSW surface were removed from...using 3M brand ‘Super 77’ spray adhesive and then hand sanding against a mechanically flat ceramic backing surface using silicon 32 carbide...weld surface using Loctite brand “5-minute Epoxy” and allowing to cure. Following the required cure period, the aluminum grating glass backing was
Zhang, Dapeng; Lv, Fan; Wang, Liyan; Sun, Liangxian; Zhou, Jian; Su, Wenyi; Bi, Peng
2007-01-01
Objective To estimate the size of the population of female sex workers (FSWs) on the basis of the HIV/AIDS behavioural surveillance approach in two Chinese cities, using a multiplier method. Method Relevant questions were inserted into the questionnaires given to two behavioural surveillance groups—female attendees of sexually transmitted disease (STD) clinics and FSWs. The size of the FSW population was derived by multiplying the number of FSWs in selected STD clinics during the study period by the proportion of FSW population who reported having attended the selected STD clinics during the same period. Results The size of the FSW population in the urban area of Xingyi, China, was estimated to be about 2500 (95% CI 2000 to 3400). This accounted for 3.6% of the total urban adult female population. There were an estimated 17 500 FSWs in the urban area of Guiyang, China (95% CI 10 300 to 31 900) or about 3.4% of its total urban adult female population (rounded to the nearest 100). Conclusions The multiplier method could be a useful and cost‐effective approach to estimate the FSW population, especially suitable in countries where HIV behavioural surveillance has been established in high‐risk populations. PMID:17090568
Strathdee, Steffanie A.; Mausbach, Brent; Lozada, Remedios; Staines-Orozco, Hugo; Semple, Shirley J.; Abramovitz, Daniela; Fraga-Vallejo, Miguel; de la Torre, Adela; Amaro, Hortensia; Martínez-Mendizábal, Gustavo; Magis-Rodríguez, Carlos; Patterson, Thomas L.
2009-01-01
Objective We recently showed efficacy of an intervention to increase condom use among female sex workers (FSWs) in Tijuana and Ciudad Juarez, situated on the Mexico–United States border. We determined whether increases in condom use were predicted by social cognitive theory and injection drug user status among women randomized to this intervention. Methods Four hundred nine HIV-negative FSWs aged ≥18 years having unprotected sex with clients within the prior 2 months received a brief individual counseling session integrating motivational interviewing and principles of behavior change (ie, HIV knowledge, self-efficacy for using condoms, and outcome expectancies). Results Increases in self-efficacy scores were associated with increases in percent condom use (P = 0.008), whereas outcome expectancies were not. Female sex workers who inject drugs (FSW-IDUs) increased condom use with clients but not to the same extent as other FSWs (P = 0.09). Change in HIV knowledge was positively associated with change in percent condom use among FSW-IDUs (P = 0.03) but not noninjection drug users. Conclusions Increases in self-efficacy significantly predicted increased condom use among FSWs, consistent with social cognitive theory. Increased HIV knowledge was also important among FSW-IDUs, but their changes in condom use were modest. Enhanced interventions for FSW-IDUs are needed, taking into account realities of substance use during sexual transactions that can compromise safer sex negotiation. PMID:19384101
Hybrid FSWeld-bonded joint fatigue behaviour
NASA Astrophysics Data System (ADS)
Lertora, Enrico; Mandolfino, Chiara; Gambaro, Carla; Pizzorni, Marco
2018-05-01
Aluminium alloys, widely used in aeronautics, are increasingly involved in the automotive industry due to the good relationship between mechanical strength and specific weight. The lightening of the structures is the first objective, which allows the decreasing in the weight in motion. The use of aluminium alloys has also seen the introduction of the Friction Stir Welding (FSW) technique for the production of structural overlapping joints. FSW allows us to weld overlap joints free from defects, but with the presence of a structural notch further aggravated by the presence of a "hook" defect near the edge of the weld. Furthermore, FSW presents a weld penetration area connected to the tool geometry and penetration. The experimental activity will be focused on the combination of two different joining techniques, which can synergistically improve the final joint resistance. In particular, the welding and bonding process most commonly known as weld-bonding is defined as a hybrid process, as it combines two different junction processes. In this paper we analyse FSWelded AA6082 aluminium alloy overlapped joint with the aim of quantitatively evaluating the improvement provided by the presence of an epoxy adhesive between the plates. After optimising the weld-bonding process, the mechanical behaviour of welded joints will be analysed by static and dynamic tests. The presence of the adhesive should limit the negative effect of the structural notch inevitable in a FSW overlapped joint.
Chow, Eric P F; Fehler, Glenda; Chen, Marcus Y; Bradshaw, Catriona S; Denham, Ian; Law, Matthew G; Fairley, Christopher K
2014-01-01
The frequency of testing sex workers for sexually transmitted infections (STIs) in Victoria, Australia, was changed from monthly to quarterly on 6 October 2012. Our aim was to determine the impact of this change to the clients seen at the Melbourne Sexual Health Centre (MHSC). Computerised medical records of all clients attending at MHSC from 7 October 2011 to 7 October 2013 were analysed. Comparing between the monthly and quarterly testing periods, the number of consultations at MSHC with female sex workers (FSW) halved from 6146 to 3453 (p<0.001) and the consultation time spent on FSW reduced by 40.6% (1942 h to 1153 h). More heterosexual men (p<0.001), and women (p<0.001) were seen in the quarterly testing period. The number of STIs diagnosed in the clinic increased from 2243 to 2589 from the monthly to quarterly period, respectively [15.4% increase (p<0.001)]. Up to AU$247,000 was saved on FSW testing after the shift to quarterly testing. The change to STIs screening frequency for sex workers from monthly to quarterly resulted in a 15% increase in STI diagnoses in the clinic and approximate a quarter of a million dollars was diverted from FSW testing to other clients. Overall the change in frequency is likely to have had a beneficial effect on STI control in Victoria.
Modeling and measurement of angle-beam wave propagation in a scatterer-free plate
NASA Astrophysics Data System (ADS)
Dawson, Alexander J.; Michaels, Jennifer E.; Michaels, Thomas E.
2017-02-01
Wavefield imaging has been shown to be a powerful tool for improving the understanding and characterization of wave propagation and scattering in plates. The complete measurement of surface displacement over a 2-D grid provided by wavefield imaging has the potential to serve as a useful means of validating ultrasonic models. Here, a preliminary study of ultrasonic angle-beam wave propagation in a scatterer-free plate using a combination of wavefield measurements and 2-D finite element models is described. Both wavefield imaging and finite element analysis are used to study the propagation of waves at a refracted angle of 56.8° propagating in a 6.35 mm thick aluminum plate. Wavefield imaging is performed using a laser vibrometer mounted on an XYZ scanning stage, which is programmed to move point-to-point on a rectilinear grid to acquire waveform data. The commercial finite element software package, PZFlex, which is specifically designed to handle large, complex ultrasonic problems, is used to create a 2-D cross-sectional model of the transducer and plate. For model validation, vertical surface displacements from both the wavefield measurements and the PZFlex finite element model are compared and found to be in excellent agreement. The validated PZFlex model is then used to explain the mechanism of Rayleigh wave generation by the angle-beam wedge. Since the wavefield measurements are restricted to the specimen surface, the cross-sectional PZFlex model is able to provide insights the wavefield data cannot. This study illustrates how information obtained from ultrasonic experiments and modeling results can be combined to improve understanding of angle-beam wave generation and propagation.
Display Considerations For Intravascular Ultrasonic Imaging
NASA Astrophysics Data System (ADS)
Gessert, James M.; Krinke, Charlie; Mallery, John A.; Zalesky, Paul J.
1989-08-01
A display has been developed for intravascular ultrasonic imaging. Design of this display has a primary goal of providing guidance information for therapeutic interventions such as balloons, lasers, and atherectomy devices. Design considerations include catheter configuration, anatomy, acoustic properties of normal and diseased tissue, catheterization laboratory and operating room environment, acoustic and electrical safety, acoustic data sampling issues, and logistical support such as image measurement, storage and retrieval. Intravascular imaging is in an early stage of development so design flexibility and expandability are very important. The display which has been developed is capable of acquisition and display of grey scale images at rates varying from static B-scans to 30 frames per second. It stores images in a 640 X 480 X 8 bit format and is capable of black and white as well as color display in multiplevideo formats. The design is based on the industry standard PC-AT architecture and consists of two AT style circuit cards, one for high speed sampling and the other for scan conversion, graphics and video generation.
Human amygdala activation by the sound produced during dental treatment: A fMRI study.
Yu, Jen-Fang; Lee, Kun-Che; Hong, Hsiang-Hsi; Kuo, Song-Bor; Wu, Chung-De; Wai, Yau-Yau; Chen, Yi-Fen; Peng, Ying-Chin
2015-01-01
During dental treatments, patients may experience negative emotions associated with the procedure. This study was conducted with the aim of using functional magnetic resonance imaging (fMRI) to visualize cerebral cortical stimulation among dental patients in response to auditory stimuli produced by ultrasonic scaling and power suction equipment. Subjects (n = 7) aged 23-35 years were recruited for this study. All were right-handed and underwent clinical pure-tone audiometry testing to reveal a normal hearing threshold below 20 dB hearing level (HL). As part of the study, subjects initially underwent a dental calculus removal treatment. During the treatment, subjects were exposed to ultrasonic auditory stimuli originating from the scaling handpiece and salivary suction instruments. After dental treatment, subjects were imaged with fMRI while being exposed to recordings of the noise from the same dental instrument so that cerebral cortical stimulation in response to aversive auditory stimulation could be observed. The independent sample confirmatory t-test was used. Subjects also showed stimulation in the amygdala and prefrontal cortex, indicating that the ultrasonic auditory stimuli elicited an unpleasant response in the subjects. Patients experienced unpleasant sensations caused by contact stimuli in the treatment procedure. In addition, this study has demonstrated that aversive auditory stimuli such as sounds from the ultrasonic scaling handpiece also cause aversive emotions. This study was indicated by observed stimulation of the auditory cortex as well as the amygdala, indicating that noise from the ultrasonic scaling handpiece was perceived as an aversive auditory stimulus by the subjects. Subjects can experience unpleasant sensations caused by the sounds from the ultrasonic scaling handpiece based on their auditory stimuli.
Human amygdala activation by the sound produced during dental treatment: A fMRI study
Yu, Jen-Fang; Lee, Kun-Che; Hong, Hsiang-Hsi; Kuo, Song-Bor; Wu, Chung-De; Wai, Yau-Yau; Chen, Yi-Fen; Peng, Ying-Chin
2015-01-01
During dental treatments, patients may experience negative emotions associated with the procedure. This study was conducted with the aim of using functional magnetic resonance imaging (fMRI) to visualize cerebral cortical stimulation among dental patients in response to auditory stimuli produced by ultrasonic scaling and power suction equipment. Subjects (n = 7) aged 23-35 years were recruited for this study. All were right-handed and underwent clinical pure-tone audiometry testing to reveal a normal hearing threshold below 20 dB hearing level (HL). As part of the study, subjects initially underwent a dental calculus removal treatment. During the treatment, subjects were exposed to ultrasonic auditory stimuli originating from the scaling handpiece and salivary suction instruments. After dental treatment, subjects were imaged with fMRI while being exposed to recordings of the noise from the same dental instrument so that cerebral cortical stimulation in response to aversive auditory stimulation could be observed. The independent sample confirmatory t-test was used. Subjects also showed stimulation in the amygdala and prefrontal cortex, indicating that the ultrasonic auditory stimuli elicited an unpleasant response in the subjects. Patients experienced unpleasant sensations caused by contact stimuli in the treatment procedure. In addition, this study has demonstrated that aversive auditory stimuli such as sounds from the ultrasonic scaling handpiece also cause aversive emotions. This study was indicated by observed stimulation of the auditory cortex as well as the amygdala, indicating that noise from the ultrasonic scaling handpiece was perceived as an aversive auditory stimulus by the subjects. Subjects can experience unpleasant sensations caused by the sounds from the ultrasonic scaling handpiece based on their auditory stimuli. PMID:26356376
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2010 CFR
2010-04-01
... Transducer ITX—Transducer, Ultrasonic, Diagnostic Diagnostic X-Ray Imaging Devices (except mammographic x-ray systems): RA 892.1600 Angiographic X-Ray System IZI—System, X-Ray, Angiographic RA 892.1650 Image-Intensified Fluoroscopic X-Ray System MQB—Solid State X-Ray Imager (Flat Panel/Digital Imager) JAA—System, X...
21 CFR Appendix B to Subpart B of... - Scope of Product Coverage
Code of Federal Regulations, 2011 CFR
2011-04-01
... Transducer ITX—Transducer, Ultrasonic, Diagnostic Diagnostic X-Ray Imaging Devices (except mammographic x-ray systems): RA 892.1600 Angiographic X-Ray System IZI—System, X-Ray, Angiographic RA 892.1650 Image-Intensified Fluoroscopic X-Ray System MQB—Solid State X-Ray Imager (Flat Panel/Digital Imager) JAA—System, X...
NASA Technical Reports Server (NTRS)
Generazio, Edward R.; Roth, Don J.; Baaklini, George Y.
1987-01-01
Acoustic images of a silicon carbide ceramic disk were obtained using a precision scanning contact pulse echo technique. Phase and cross-correlation velocity, and attenuation maps were used to form color images of microstructural variations. These acoustic images reveal microstructural variations not observable with X-ray radiography.
Composite ultrasound imaging apparatus and method
Morimoto, Alan K.; Bow, Jr., Wallace J.; Strong, David Scott; Dickey, Fred M.
1998-01-01
An imaging apparatus and method for use in presenting composite two dimensional and three dimensional images from individual ultrasonic frames. A cross-sectional reconstruction is applied by using digital ultrasound frames, transducer orientation and a known center. Motion compensation, rank value filtering, noise suppression and tissue classification are utilized to optimize the composite image.
Composite ultrasound imaging apparatus and method
Morimoto, A.K.; Bow, W.J. Jr.; Strong, D.S.; Dickey, F.M.
1998-09-15
An imaging apparatus and method for use in presenting composite two dimensional and three dimensional images from individual ultrasonic frames. A cross-sectional reconstruction is applied by using digital ultrasound frames, transducer orientation and a known center. Motion compensation, rank value filtering, noise suppression and tissue classification are utilized to optimize the composite image. 37 figs.
Pfefferkorn, Frank E; Bello, Dhimiter; Haddad, Gilbert; Park, Ji-Young; Powell, Maria; McCarthy, Jon; Bunker, Kristin Lee; Fehrenbacher, Axel; Jeon, Yongho; Virji, M Abbas; Gruetzmacher, George; Hoover, Mark D
2010-07-01
Friction stir welding (FSW) is considered one of the most significant developments in joining technology over the last half century. Its industrial applications are growing steadily and so are the number of workers using this technology. To date, there are no reports on airborne exposures during FSW. The objective of this study was to investigate possible emissions of nanoscale (<100 nm) and fine (<1 microm) aerosols during FSW of two aluminum alloys in a laboratory setting and characterize their physicochemical composition. Several instruments measured size distributions (5 nm to 20 microm) with 1-s resolution, lung deposited surface areas, and PM(2.5) concentrations at the source and at the breathing zone (BZ). A wide range aerosol sampling system positioned at the BZ collected integrated samples in 12 stages (2 nm to 20 microm) that were analyzed for several metals using inductively coupled plasma mass spectrometry. Airborne aerosol was directly collected onto several transmission electron microscope grids and the morphology and chemical composition of collected particles were characterized extensively. FSW generates high concentrations of ultrafine and submicrometer particles. The size distribution was bimodal, with maxima at approximately 30 and approximately 550 nm. The mean total particle number concentration at the 30 nm peak was relatively stable at approximately 4.0 x 10(5) particles cm(-3), whereas the arithmetic mean counts at the 550 nm peak varied between 1500 and 7200 particles cm(-3), depending on the test conditions. The BZ concentrations were lower than the source concentrations by 10-100 times at their respective peak maxima and showed higher variability. The daylong average metal-specific concentrations were 2.0 (Zn), 1.4 (Al), and 0.24 (Fe) microg m(-3); the estimated average peak concentrations were an order of magnitude higher. Potential for significant exposures to fine and ultrafine aerosols, particularly of Al, Fe, and Zn, during FSW may exist, especially in larger scale industrial operations.
Pfefferkorn, Frank E.; Bello, Dhimiter; Haddad, Gilbert; Park, Ji-Young; Powell, Maria; Mccarthy, Jon; Bunker, Kristin Lee; Fehrenbacher, Axel; Jeon, Yongho; Virji, M. Abbas; Gruetzmacher, George; Hoover, Mark D.
2010-01-01
Friction stir welding (FSW) is considered one of the most significant developments in joining technology over the last half century. Its industrial applications are growing steadily and so are the number of workers using this technology. To date, there are no reports on airborne exposures during FSW. The objective of this study was to investigate possible emissions of nanoscale (<100 nm) and fine (<1 μm) aerosols during FSW of two aluminum alloys in a laboratory setting and characterize their physicochemical composition. Several instruments measured size distributions (5 nm to 20 μm) with 1-s resolution, lung deposited surface areas, and PM2.5 concentrations at the source and at the breathing zone (BZ). A wide range aerosol sampling system positioned at the BZ collected integrated samples in 12 stages (2 nm to 20 μm) that were analyzed for several metals using inductively coupled plasma mass spectrometry. Airborne aerosol was directly collected onto several transmission electron microscope grids and the morphology and chemical composition of collected particles were characterized extensively. FSW generates high concentrations of ultrafine and submicrometer particles. The size distribution was bimodal, with maxima at ∼30 and ∼550 nm. The mean total particle number concentration at the 30 nm peak was relatively stable at ∼4.0 × 105 particles cm−3, whereas the arithmetic mean counts at the 550 nm peak varied between 1500 and 7200 particles cm−3, depending on the test conditions. The BZ concentrations were lower than the source concentrations by 10–100 times at their respective peak maxima and showed higher variability. The daylong average metal-specific concentrations were 2.0 (Zn), 1.4 (Al), and 0.24 (Fe) μg m−3; the estimated average peak concentrations were an order of magnitude higher. Potential for significant exposures to fine and ultrafine aerosols, particularly of Al, Fe, and Zn, during FSW may exist, especially in larger scale industrial operations. PMID:20453001
NASA Astrophysics Data System (ADS)
Baghdadi, Amir Hossein; Fazilah Mohamad Selamat, Nor; Sajuri, Zainuddin
2017-09-01
Automotive and aerospace industries are attempting to produce lightweight structure by using materials with low density such as aluminum and magnesium alloys to increase the fuel efficiency and consequently reduce the environmental pollution. It can be beneficial to join Mg to Al to acquire ideal performance in special applications. Friction stir welding (FSW) is solid state welding processes and relatively lower temperature of the process compared to fusion welding processes. This makes FSW a potential joining technique for joining of the dissimilar materials. In this study, Mg-Al butt joints were performed by FSW under different tool offset conditions, rotation rates (500-600 rpm) and traverse speeds (20 mm/min) with tool axis offset 1 mm shifted into AZ31B or Al6061 (T6), and without offset. During the welding process AZ31B was positioned at the advancing side (AS) and Al6061 (T6) was located at the retreating side (RS). Defect free AZ31B-Al6061 (T6) dissimilar metal FSW joints with good mechanical properties were obtained with the combination of intermediate rotation rate and low traverse speed pin is in the middle. When tool positioned in -1 mm or +1 mm offsetting, some defects were found in SZ of dissimilar FSWed joints such as cavity, tunnel, and crack. Furthermore, a thin layer of intermetallic compounds was observed in the stir zone at the interface between Mg-Al plates. The strength of the joint was influenced by FSW parameters. Good mechanical properties obtained with the combination of intermediate rotational speed of 600 rpm and low travelling speed of 20 mm/min by locating Mg on advancing side when pin is in the middle. Also, Joint efficiency of the welds prepared in the present study was between 29% and 68% for the different welding parameters.
Low-Temperature Friction-Stir Welding of 2024 Aluminum
NASA Technical Reports Server (NTRS)
Benavides, S.; Li, Y.; Murr, L. E.; Brown, D.; McClure, J. C.
1998-01-01
Solid state friction-stir welding (FSW) has been demonstrated to involve dynamic recrystallization producing ultra-fine, equiaxed grain structures to facilitate superplastic deformation as the welding or joining mechanism. However, the average residual, equiaxed, grain size in the weld zone has ranged from roughly 0.5 micron to slightly more than 10 micron, and the larger weld zone grain sizes have been characterized as residual or static grain growth as a consequence of the temperatures in the weld zone (where center-line temperatures in the FSW of 6061 Al have been shown to be as high as 480C or -0.8 T(sub M) where T(sub M) is the absolute melting temperature)). In addition, the average residual weld zone grain size has been observed to increase near the top of the weld, and to decrease with distance on either side of the weld-zone centerline, an d this corresponds roughly to temperature variations within the weld zone. The residual grain size also generally decreases with decreasing FSW tool rotation speed. These observations are consistent with the general rules for recrystallization where the recrystallized grain size decreases with increasing strain (or deformation) at constant strain rate, or with increasing strain-rate, or with increasing strain rate at constant strain; especially at lower ambient temperatures, (or annealing temperatures). Since the recrystallization temperature also decreases with increasing strain rate, the FSW process is somewhat complicated because the ambient temperature, the frictional heating fraction, and the adiabatic heating fraction )proportional to the product of strain and strain-rate) will all influence both the recrystallization and growth within the FSW zone. Significantly reducing the ambient temperature of the base metal or work pieces to be welded would be expected to reduce the residual weld-zone grain size. The practical consequences of this temperature reduction would be the achievement of low temperature welding. This study compares the residual grain sizes and microstructures in 2024 Al friction-stir welded at room temperature (about 30C and low temperature (-30C).
Two-Element Transducer for Ultrasound
NASA Technical Reports Server (NTRS)
Lecroissette, D. H.; Heyser, R. C.
1986-01-01
Separation of transmitting and receiving units improves probing of deep tissue. Ultrasonic transducer has dual elements to increase depth at which sonic images are made of biological tissue. Transducer uses separate transmitting and receiving elements, and frequency response of receiving element independently designed to accommodate attenuation of higher frequencies by tissue. New transducer intended for pulse-echo ultrasonic systems in which reflected sound pulses reveal features in tissue.
NASA Astrophysics Data System (ADS)
Cassidy, Nigel J.; Eddies, Rod; Dods, Sam
2011-08-01
Ground-penetrating radar (GPR) and ultrasonic 'pulse echo' techniques are well-established methods for the imaging, investigation and analysis of steel reinforced concrete structures and are important civil engineering survey tools. GPR is, arguably, the more widely-used technique as it is suitable for a greater range of problem scenarios (i.e., from rebar mapping to moisture content determination). Ultrasonic techniques are traditionally associated with the engineering-based, non-destructive testing of concrete structures and their integrity analyses (e.g., flaw detection, shear/longitudinal velocity determination, etc). However, when used in an appropriate manner, both techniques can be considered complementary and provide a unique way of imaging the sub-surface that is suited to a range of geotechnical problems. In this paper, we present a comparative study between mid-to-high frequency GPR (450 MHz and 900 MHz) and array-based, shear wave, pulse-echo ultrasonic surveys using proprietary instruments and conventional GPR data processing and visualisation techniques. Our focus is the practical detection of sub-metre scale voids located under steel reinforced concrete sections in realistic survey conditions (e.g., a capped, relict mine shaft or vent). Representative two-dimensional (2D) sections are presented for both methods illustrating the similarities/differences in signal response and the temporal-spatial target resolutions achieved with each technique. The use of three-dimensional data volumes and time slices (or 'C-scans') for advanced interpretation is also demonstrated, which although common in GPR applications is under-utilised as a technique in general ultrasonic surveys. The results show that ultrasonic methods can perform as well as GPR for this specific investigation scenario and that they have the potential of overcoming some of the inherent limitations of GPR investigations (i.e., the need for careful antenna frequency selection and survey design in order to image through the rebar meshes). More importantly, we show that standard GPR data collection, processing and visualisation techniques can be used with both types of data without users needing to change existing operational protocols or survey criteria.
A new approach to ultrasonic elasticity imaging
NASA Astrophysics Data System (ADS)
Hoerig, Cameron; Ghaboussi, Jamshid; Fatemi, Mostafa; Insana, Michael F.
2016-04-01
Biomechanical properties of soft tissues can provide information regarding the local health status. Often the cells in pathological tissues can be found to form a stiff extracellular environment, which is a sensitive, early diagnostic indicator of disease. Quasi-static ultrasonic elasticity imaging provides a way to image the mechanical properties of tissues. Strain images provide a map of the relative tissue stiffness, but ambiguities and artifacts limit its diagnostic value. Accurately mapping intrinsic mechanical parameters of a region may increase diagnostic specificity. However, the inverse problem, whereby force and displacement estimates are used to estimate a constitutive matrix, is ill conditioned. Our method avoids many of the issues involved with solving the inverse problem, such as unknown boundary conditions and incomplete information about the stress field, by building an empirical model directly from measured data. Surface force and volumetric displacement data gathered during imaging are used in conjunction with the AutoProgressive method to teach artificial neural networks the stress-strain relationship of tissues. The Autoprogressive algorithm has been successfully used in many civil engineering applications and to estimate ocular pressure and corneal stiffness; here, we are expanding its use to any tissues imaged ultrasonically. We show that force-displacement data recorded with an ultrasound probe and displacements estimated at a few points in the imaged region can be used to estimate the full stress and strain vectors throughout an entire model while only assuming conservation laws. We will also demonstrate methods to parameterize the mechanical properties based on the stress-strain response of trained neural networks. This method is a fundamentally new approach to medical elasticity imaging that for the first time provides full stress and strain vectors from one set of observation data.
Bhardwaj, Anuj; Velmurugan, Natanasabapathy; Ballal, Suma
2013-01-01
Present study evaluated the efficacy of natural derivative irrigants, Morinda citrifolia juice (MCJ), Aloe Vera and Propolis in comparison to 1% sodium hypochlorite with passive ultrasonic irrigation for removal of the intraradicular E. faecalis biofilms in extracted single rooted human permanent teeth. Biofilms of E. faecalis were grown on the prepared root canal walls of 60 standardized root halves which were longitudinally sectioned. These root halves were re-approximated and the samples were divided into five groups of twelve each. The groups were, Group A (1% NaOCl), Group B (MCJ), Group C (Aloe vera), Group D (Propolis) and Group E (Saline). These groups were treated with passive ultrasonic irrigation (PUI) along with the respective irrigants. The root halves were processed for scanning electron microscopy. Three images (X2.5), coronal, middle and apical, were taken for the twelve root halves in each of the five groups. The images were randomized and biofilm coverage assessed independently by three calibrated examiners, using a four-point scoring system. 1% NaOCl with passive ultrasonic irrigation (PUI) was effective in completely removing E. faecalis biofilm and was superior to the natural irrigants like MCJ, Aloe vera and Propolis tested in this study. 1% NaOCl used along with passive ultrasonic irrigation was effective in completely removing E. faecalis biofilm when compared to natural irrigants (MCJ, Aloe Vera and Propolis).
NASA Astrophysics Data System (ADS)
Zhu, Lili; Wu, Jingping; Lin, Guimin; Hu, Liangjun; Li, Hui
2016-10-01
With high spatial resolution of ultrasonic location and high sensitivity of optical detection, ultrasound-modulated optical tomography (UOT) is a promising noninvasive biological tissue imaging technology. In biological tissue, the ultrasound-modulated light signals are very weak and are overwhelmed by the strong unmodulated light signals. It is a difficulty and key to efficiently pick out the weak modulated light from strong unmodulated light in UOT. Under the effect of an ultrasonic field, the scattering light intensity presents a periodic variation as the ultrasonic frequency changes. So the modulated light signals would be escape from the high unmodulated light signals, when the modulated light signals and the ultrasonic signal are processed cross correlation operation by a lock-in amplifier and without a chopper. Experimental results indicated that the signal-to-noise ratio of UOT is significantly improved by a lock-in amplifier, and the higher the repetition frequency of pulsed ultrasonic wave, the better the signal-to-noise ratio of UOT.
Nonlinear ultrasonic imaging with X wave
NASA Astrophysics Data System (ADS)
Du, Hongwei; Lu, Wei; Feng, Huanqing
2009-10-01
X wave has a large depth of field and may have important application in ultrasonic imaging to provide high frame rate (HFR). However, the HFR system suffers from lower spatial resolution. In this paper, a study of nonlinear imaging with X wave is presented to improve the resolution. A theoretical description of realizable nonlinear X wave is reported. The nonlinear field is simulated by solving the KZK nonlinear wave equation with a time-domain difference method. The results show that the second harmonic field of X wave has narrower mainlobe and lower sidelobes than the fundamental field. In order to evaluate the imaging effect with X wave, an imaging model involving numerical calculation of the KZK equation, Rayleigh-Sommerfeld integral, band-pass filtering and envelope detection is constructed to obtain 2D fundamental and second harmonic images of scatters in tissue-like medium. The results indicate that if X wave is used, the harmonic image has higher spatial resolution throughout the entire imaging region than the fundamental image, but higher sidelobes occur as compared to conventional focus imaging. A HFR imaging method with higher spatial resolution is thus feasible provided an apodization method is used to suppress sidelobes.
Evaluation of Friction Stir Processing of HY-80 Steel Under Wet and Dry Conditions
2012-03-01
MS80. The tool design included a convex scroll shoulder with a step-spiral protruding pin (CS4). Figure 4. PCBN FSW/P threaded tool. 12 For...and cooling water was pumped through during the FSW/P process, Figure 7. Sea salt was added to distilled water to create a 3.5% salt content. 14... Vacuum hot extraction was used to determine the hydrogen concentration as specified by ASTM E 146–83. In addition, combustion infrared detection
Statistical Analysis of High-Cycle Fatigue Behavior of Friction Stir Welded AA5083-H321
2011-01-01
durable structures are: (a) FSW is 111being used in a serial production of aluminum alloy -based 112ferryboat deck structures in Finland; (b) Al-Mg- Si -based...and strain-hardened/stabilized Al-Mg-Mn alloy ) are characterized by a relatively large statistical scatter. This scatter is closely related to the...associated with friction stir-welded (FSW) joints of AA5083-H321 (a solid-solution-strengthened and strain-hardened/stabilized Al-Mg-Mn alloy ) are
Computational Analysis of Material Flow During Friction Stir Welding of AA5059 Aluminum Alloys
2011-01-01
tool material (AISI H13 tool steel ) is modeled as an isotropic linear-elastic material. Within the analysis, the effects of some of the FSW key process...threads/m; (b) tool 598 material = AISI H13 tool steel ; (c) workpiece material = 599 AA5059; (d) tool rotation speed = 500 rpm; (e) tool travel 600 speed...the strain-hardening term is augmented to take into account for the effect of dynamic recrystallization) while the FSW tool material (AISI H13
Modeling of AA5083 Material-Microstructure Evolution During Butt Friction-Stir Welding
2010-07-01
a rigid material. Its density and thermal properties are set to that of AISI- H13 , the hot-worked tool steel which is often used as a FSW- tool ...joining process (Ref 1-3). Within FSW, a (typically) cylindrical tool - pin (threaded at the bottom and terminated with a circular-plate shape shoulder...applied to the shoulder and owing to frictional sliding and plastic deforma- tion, substantial amount of heat is generated at the tool /work- piece
Vacuum-bag-only processing of composites
NASA Astrophysics Data System (ADS)
Thomas, Shad
Ultrasonic imaging in the C-scan mode in conjunction with the amplitude of the reflected signal was used to measure flow rates of an epoxy resin film penetrating through the thickness of single layers of woven carbon fabric. Assemblies, comprised of a single layer of fabric and film, were vacuum-bagged and ultrasonically scanned in a water tank during impregnation at 50°C, 60°C, 70°C, and 80°C. Measured flow rates were plotted versus inverse viscosity to determine the permeability in the thin film, non-saturated system. The results demonstrated that ultrasonic imaging in the C-scan mode is an effective method of measuring z-direction resin flow through a single layer of fabric. The permeability values determined in this work were consistent with permeability values reported in the literature. Capillary flow was not observed at the temperatures and times required for pressurized flow to occur. The flow rate at 65°C was predicted from the linear plot of flow rate versus inverse viscosity. The effects of fabric architecture on through-thickness flow rates during impregnation of an epoxy resin film were measured by ultrasonic imaging. Multilayered laminates comprised of woven carbon fabrics and epoxy films (prepregs) were fabricated by vacuum-bagging. Ultrasonic imaging was performed in a heated water tank (65°C) during impregnation. Impregnation rates showed a strong dependence on fabric architecture, despite similar areal densities. Impregnation rates are directly affected by inter-tow spacing and tow nesting, which depend on fabric architecture, and are indirectly affected by areal densities. A new method of predicting resin infusion rates in prepreg and resin film infusion processes was proposed. The Stokes equation was used to derive an equation to predict the impregnation rate of laminates as a function of fabric architecture. Flow rate data previously measured by ultrasound was analyzed with the new equation and the Kozeny-Carman equation. A fiber interaction parameter was determined as a function of fabric architecture. The derived equation is straight-forward to use, unlike the Kozeny-Carman equation. The results demonstrated that the newly derived equation can be used to predict the resin infusion rate of multilayer laminates.
Agger, Peter; Stephenson, Robert S; Dobrzynski, Halina; Atkinson, Andrew; Iaizzo, Paul A; Anderson, Robert H; Jarvis, Jonathan C; Allan, Sarah L; Partridge, John B; Zhao, Jichao; Zhang, Henggui; MacIver, David H
2016-10-01
The anatomical substrate for the mid-mural ventricular hyperechogenic zone remains uncertain, but it may represent no more than ultrasound reflected from cardiomyocytes orientated orthogonally to the ultrasonic beam. We sought to ascertain the relationship between the echogenic zone and the orientation of the cardiomyocytes. We used 3D echocardiography, diffusion tensor imaging, and microcomputed tomography to analyze the location and orientation of cardiomyocytes within the echogenic zone. We demonstrated that visualization of the echogenic zone is dependent on the position of the transducer and is most clearly seen from the apical window. Diffusion tensor imaging and microcomputed tomography show that the echogenic zone seen from the apical window corresponds to the position of the circumferentially orientated cardiomyocytes. An oblique band seen in the parasternal view relates to cardiomyocytes orientated orthogonally to the ultrasonic beam. The mid-mural ventricular hyperechogenic zone represents reflected ultrasound from cardiomyocytes aligned orthogonal to the ultrasonic beam. The echogenic zone does not represent a space, a connective tissue sheet, a boundary between ascending and descending limbs of a hypothetical helical ventricular myocardial band, nor an abrupt change in cardiomyocyte orientation. © 2016, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zalev, Jason; Clingman, Bryan; Smith, Remie J.; Herzog, Don; Miller, Tom; Stavros, A. Thomas; Ermilov, Sergey; Conjusteau, André; Tsyboulski, Dmitri; Oraevsky, Alexander A.; Kist, Kenneth; Dornbluth, N. C.; Otto, Pamela
2013-03-01
We report on findings from the clinical feasibility study of the ImagioTM. Breast Imaging System, which acquires two-dimensional opto-acoustic (OA) images co-registered with conventional ultrasound using a specialized duplex hand-held probe. Dual-wavelength opto-acoustic technology is used to generate parametric maps based upon total hemoglobin and its oxygen saturation in breast tissues. This may provide functional diagnostic information pertaining to tumor metabolism and microvasculature, which is complementary to morphological information obtained with conventional gray-scale ultrasound. We present co-registered opto-acoustic and ultrasonic images of malignant and benign tumors from a recent clinical feasibility study. The clinical results illustrate that the technology may have the capability to improve the efficacy of breast tumor diagnosis. In doing so, it may have the potential to reduce biopsies and to characterize cancers that were not seen well with conventional gray-scale ultrasound alone.
NASA Astrophysics Data System (ADS)
Livings, R. A.; Dayal, V.; Barnard, D. J.; Hsu, D. K.
2012-05-01
Ceramic tiles are the main ingredient of a multi-material, multi-layered composite being considered for the modernization of tank armors. The high stiffness, low attenuation, and precise dimensions of these uniform tiles make them remarkable resonators when driven to vibrate. Defects in the tile, during manufacture or after usage, are expected to change the resonance frequencies and resonance images of the tile. The comparison of the resonance frequencies and resonance images of a pristine tile/lay-up to a defective tile/lay-up will thus be a quantitative damage metric. By examining the vibrational behavior of these tiles and the composite lay-up with Finite Element Modeling and analytical plate vibration equations, the development of a new Nondestructive Evaluation technique is possible. This study examines the development of the Air-Coupled Ultrasonic Resonance Imaging technique as applied to a hexagonal ceramic tile and a multi-material, multi-layered composite.
AlN-based piezoelectric micromachined ultrasonic transducer for photoacoustic imaging
NASA Astrophysics Data System (ADS)
Chen, Bingzhang; Chu, Futong; Liu, Xingzhao; Li, Yanrong; Rong, Jian; Jiang, Huabei
2013-07-01
We report on the fabrication of a piezoelectric micromachined ultrasonic transducer (pMUT) and its application to photoacoustic imaging. With c-axis orientation, AlN was grown on a 300 nm-thick SiO2 film and a 200 nm-thick bottom electrode at room temperature. The device consists of SiO2, bottom electrode, AlN films, upper electrode, and polyimide protective layer. An area ratio of 0.45 was used between the upper electrode and the vibration area of the pMUT to provide an optimal sensitivity of transducer. Its resonant frequency was measured to be 2.885 MHz, and the coupling coefficient in the range of 2.38%-3.71%. The fabricated pMUT was integrated with a photoacoustic imaging system and photoacoustic image of a phantom was obtained. The resolution of the system was measured to be about 240 μm.
Preparation of nanobubbles for ultrasound imaging and intracelluar drug delivery.
Wang, Ye; Li, Xiang; Zhou, Yan; Huang, Pengyu; Xu, Yuhong
2010-01-15
Echogenic bubble formulations have wide applications in both disease diagnosis and therapy. In the current study, nanobubbles were prepared and the contrast agent function was evaluated in order to study the nanosized bubble's property for ultrasonic imaging. Coumarin-6 as a model drug was loaded into nanobubbles to investigate the drug delivery potential to cells. The results showed that the nanobubbles composed of 1% of Tween 80, and 3 mg/ml of lipid worked well as an ultrasonic contrast agent by presenting a contrast effect in the liver region in vivo. The drug-loaded nanobubbles could enhance drug delivery to cells significantly, and the process was analyzed by sigmoidally fitting the pharmacokinetic curve. It can be concluded that the nanobubble formulation is a promising approach for both ultrasound imaging and drug delivery enhancing.
Capacitive micromachined ultrasonic transducers for medical imaging and therapy.
Khuri-Yakub, Butrus T; Oralkan, Omer
2011-05-01
Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure, and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated frontend electronic circuits we developed and their use for 2-D and 3-D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a MEMS technology for many medical diagnostic and therapeutic applications.
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Khuri-Yakub, Butrus T.; Oralkan, Ömer
2011-01-01
Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure, and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated frontend electronic circuits we developed and their use for 2-D and 3-D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a MEMS technology for many medical diagnostic and therapeutic applications. PMID:21860542
Response of capacitive micromachined ultrasonic transducers
NASA Astrophysics Data System (ADS)
Ge, Lifeng
2008-10-01
Capacitive micromachined ultrasonic transducers (CMUTs) have been developed for airborne ultrasonic applications, acoustic imaging, and chemical and biological detections. Much attention is also paid how to optimize their performance, so that the accurate simulation of the transmitting response of the CMUTs becomes extremely significant. This paper focuses on determining the total input mechanical impedance accountings for damping, and its resistance part is obtained by the calculated natural frequency and equivalent lumped parameters, and the typical 3-dB bandwidth. Thus, the transmitting response can be calculated by using the input mechanical impedance. Moreover, the equivalent electrical circuit can be also established by the determined lumped parameters.
NASA Astrophysics Data System (ADS)
Arnal, Bastien; Pernot, Mathieu; Fink, Mathias; Tanter, Mickael
2012-08-01
This Letter presents a time reversal cavity that has both a high reverberation time and a good transmission factor. A multiple scattering medium has been embedded inside a fluid-filled reverberating cavity. This allows creating smart ultrasonic sources able to generate very high pressure pulses at the focus outside the cavity with large steering capabilities. Experiments demonstrate a 25 dB gain in pressure at the focus. This concept will enable us to convert conventional ultrasonic imaging probes driven by low power electronics into high power probes for therapeutic applications requiring high pressure focused pulses, such as histotripsy or lithotripsy.
Ultrasonic nondestructive evaluation of graphite epoxy composite laminates
NASA Technical Reports Server (NTRS)
Miller, James G.
1990-01-01
Quantitative ultrasonic techniques are summarized with applications to the measurement of frequency-dependent attenuation and backscatter and to the NDE of composite laminates. Results are listed for the ultrasonic NDE of graphite-epoxy composite laminates including impact and fatigue damage as well as porosity. The methods reviewed include transmission measurements of attenuation, reconstructive tomography based on attenuation, estimating attenuation from backscattered ultrasound, and backscatter approaches. Phase-sensitive and -insensitive detection techniques are mentioned such as phase cancellation at piezoelectric receiving transducers and acoustoelectric effects. The techniques permit the NDE of the parameters listed in inhomogeneous media and provide both images from the transmission mode and in the reflection mode.
An Abdominal Aorta Wall Extraction for Liver Cirrhosis Classification Using Ultrasonic Images
NASA Astrophysics Data System (ADS)
Hayashi, Takaya; Fujita, Yusuke; Mitani, Yoshihiro; Hamamoto, Yoshihiko; Segawa, Makoto; Terai, Shuji; Sakaida, Isao
2011-06-01
We propose a method to extract an abdominal aorta wall from an M-mode image. Furthermore, we propose the use of a Gaussian filter in order to improve image quality. The experimental results show that the Gaussian filter is effective in the abdominal aorta wall extraction.
Computer analysis of gallbladder ultrasonic images towards recognition of pathological lesions
NASA Astrophysics Data System (ADS)
Ogiela, M. R.; Bodzioch, S.
2011-06-01
This paper presents a new approach to gallbladder ultrasonic image processing and analysis towards automatic detection and interpretation of disease symptoms on processed US images. First, in this paper, there is presented a new heuristic method of filtering gallbladder contours from images. A major stage in this filtration is to segment and section off areas occupied by the said organ. This paper provides for an inventive algorithm for the holistic extraction of gallbladder image contours, based on rank filtration, as well as on the analysis of line profile sections on tested organs. The second part concerns detecting the most important lesion symptoms of the gallbladder. Automating a process of diagnosis always comes down to developing algorithms used to analyze the object of such diagnosis and verify the occurrence of symptoms related to given affection. The methodology of computer analysis of US gallbladder images presented here is clearly utilitarian in nature and after standardising can be used as a technique for supporting the diagnostics of selected gallbladder disorders using the images of this organ.
Point spread functions and deconvolution of ultrasonic images.
Dalitz, Christoph; Pohle-Fröhlich, Regina; Michalk, Thorsten
2015-03-01
This article investigates the restoration of ultrasonic pulse-echo C-scan images by means of deconvolution with a point spread function (PSF). The deconvolution concept from linear system theory (LST) is linked to the wave equation formulation of the imaging process, and an analytic formula for the PSF of planar transducers is derived. For this analytic expression, different numerical and analytic approximation schemes for evaluating the PSF are presented. By comparing simulated images with measured C-scan images, we demonstrate that the assumptions of LST in combination with our formula for the PSF are a good model for the pulse-echo imaging process. To reconstruct the object from a C-scan image, we compare different deconvolution schemes: the Wiener filter, the ForWaRD algorithm, and the Richardson-Lucy algorithm. The best results are obtained with the Richardson-Lucy algorithm with total variation regularization. For distances greater or equal twice the near field distance, our experiments show that the numerically computed PSF can be replaced with a simple closed analytic term based on a far field approximation.
Photoacoustic microscopic imaging of surface and subsurface damages in CFRP
NASA Astrophysics Data System (ADS)
Nakahata, Kazuyuki; Ogi, Keiji; Namita, Takeshi; Ohira, Katsumi; Maruyama, Masayuki; Shiina, Tsuyoshi
2018-04-01
Photoacoustic imaging comprises an optical excitation within a target zone and the detection of the ultrasonic wave so created. A pulsed laser illuminates the target zone, and this illumination causes rapid thermoelastic expansion that generates a broadband high-frequency ultrasonic wave (photoacoustic wave, PA). In this paper, we report proof-of-concept experiments for nondestructive testing of laminar materials using a PA microscope. A specimen containing carbon-fiber-reinforced plastic (CFRP) was used in this experiment and involved an artificial delamination. A 532-nm-wavelength laser irradiates the top surface of the specimen, and the resulting ultrasonic waves are received by a point-focusing immersion transducer on the same side. Our system estimated the depth and dimension of the subsurface delamination accurately. By coating a light-absorbing material on the surface, the amplitude of the PA wave increased. This finding shows that the signal-noise (S/N) ratio of the scattered wave from delaminations can be improved with the surface coatings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sword, Charles K.
The present invention relates to an ultrasonic scanner and method for the imaging of a part surface, the scanner comprising: a probe assembly spaced apart from the surface including at least two tracking signals for emitting electromagnetic radiation and a transmitter for emitting ultrasonic waves onto a surface in order to induce at least a portion of said waves to be reflected from the surface, at least one detector for receiving the electromagnetic radiation wherein the detector is positioned to receive said radiation from the tracking signals, an analyzing means for recognizing a three-dimensional location of the tracking signals basedmore » on said emitted electromagnetic radiation, a differential conversion means for generating an output signal representative of the waveform of the reflected waves, and a means for relating said tracking signal location with the output signal and projecting an image of the resulting data. The scanner and method are particularly useful to acquire ultrasonic inspection data by scanning the probe-over a complex part surface in an arbitrary scanning pattern.« less
Sword, Charles K.
2000-01-01
The present invention relates to an ultrasonic scanner system and method for the imaging of a part system, the scanner comprising: a probe assembly spaced apart from the surface of the part including at least two tracking signals for emitting radiation and a transmitter for emitting ultrasonic waves onto a surface in order to induce at least a portion of the waves to be reflected from the part, at least one detector for receiving the radiation wherein the detector is positioned to receive the radiation from the tracking signals, an analyzer for recognizing a three-dimensional location of the tracking signals based on the emitted radiation, a differential converter for generating an output signal representative of the waveform of the reflected waves, and a device such as a computer for relating said tracking signal location with the output signal and projecting an image of the resulting data. The scanner and method are particularly useful to acquire ultrasonic inspection data by scanning the probe over a complex part surface in an arbitrary scanning pattern.
Nondestructive characterization of UHMWPE armor materials
NASA Astrophysics Data System (ADS)
Chiou, Chien-Ping; Margetan, Frank J.; Barnard, Daniel J.; Hsu, David K.; Jensen, Terrence; Eisenmann, David
2012-05-01
Ultra-high molecular weight polyethylene (UHMWPE) is a material increasingly used for fabricating helmet and body armor. In this work, plate specimens consolidated from thin fiber sheets in series 3124 and 3130 were examined with ultrasound, X-ray and terahertz radiation. Ultrasonic through-transmission scans using both air-coupled and immersion modes revealed that the 3130 series material generally had much lower attenuation than the 3124 series, and that certain 3124 plates had extremely high attenuation. Due to the relatively low inspection frequencies used, pulse-echo immersion ultrasonic testing could not detect distinct flaw echoes from the interior. To characterize the nature of the defective condition that was responsible for the high ultrasonic attenuation, terahertz radiation in the time-domain spectroscopy mode were used to image the flaws. Terahertz scan images obtained on the high attenuation samples clearly showed a distribution of a large number of defects, possibly small planar delaminations, throughout the volume of the interior. Their precise nature and morphology are to be verified by optical microscopy of the sectioned surface.
Xie, Jiulong; Hse, Chung-Yun; De Hoop, Cornelis F; Hu, Tingxing; Qi, Jinqiu; Shupe, Todd F
2016-10-20
Cellulose nanofibers were successfully isolated from bamboo using microwave liquefaction combined with chemical treatment and ultrasonic nanofibrillation processes. The microwave liquefaction could eliminate almost all the lignin in bamboo, resulting in high cellulose content residues within 7min, and the cellulose enriched residues could be readily purified by subsequent chemical treatments with lower chemical charging and quickly. The results of wet chemistry analyses, SEM images, and FTIR and X-ray spectra indicated the combination of microwave liquefaction and chemical treatment was significantly efficient in removing non-cellulosic compounds. Ultrasonication was used to separate the nanofibrils from the purified residues to extract nanofibers. The TEM images confirmed the presence of elementary fibrils, nano-sized fibril bundles, and aggregated fibril bundles. As evidenced by the TGA analysis, cellulose nanofibers isolated by this novel technique had high thermal stability indicating that the isolated nanofibers could possibly be applied as reinforcing elements in biomaterials. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effect of rotation speed and welding speed on Friction Stir Welding of AA1100 Aluminium alloy
NASA Astrophysics Data System (ADS)
Raja, P.; Bojanampati, S.; Karthikeyan, R.; Ganithi, R.
2018-04-01
Aluminum AA1100 is the most widely used grade of Aluminium due to its excellent corrosion resistance, high ductility and reflective finish, the selected material was welded with Friction Stir Welding (FSW) process on a CNC machine, using a combination of different tool rotation speed (1500 rpm, 2500 rpm, 3500 rpm) and welding speed (10 mm/min, 30 mm/min, 50 mm/min) as welding parameters. The effect of FSW using this welding parameter was studied by measuring the ultimate tensile strength of the welded joints. A high-speed steel tool was prepared for welding the Aluminium AA1100 alloy having an 8mm shoulder diameter and pin dimension of 4mm diameter and 2.8 mm length. The welded joints were tested using the universal testing machine. It was found that Ultimate Tensile Strength of FSW specimen was highest with a value of 98.08 MPa when the weld was performed at rotation speed of 1500 RPM and welding speed of 50 mm/min.
Ulibarri, Monica D; Hiller, Sarah P; Lozada, Remedios; Rangel, M Gudelia; Stockman, Jamila K; Silverman, Jay G; Ojeda, Victoria D
2013-01-01
This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors-ever experiencing forced sex and forced sex in the context of sex work-were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.
Rabby, Reza; Tang, Wei; Reynolds, A. P.
2015-05-13
In this article, the effect of pin features and orientation/placement of the materials on advancing side were investigated for friction stir welding (FSW) of dissimilar aluminum alloys AA2050 and AA6061. Pins for FSW were produced with a 2.12 mm pitch thread having three flats/flutes. Three sets of rotational speed/welding speed were used to perform a series of welds in a butt joint arrangement. The results show that, joint quality, process response variables and welding temperature are highly affected by pin features and material orientation in FSW. Defect free joints with effective material transportation in the weld nugget zone were obtainedmore » when welding was performed with AA2050 on the advancing side. The tool also encounters less in-plane reaction force for welding with 2050 on the advancing side. Pin with thread+3 flats produces quality welds at low rotational and travel speed regardless of the location of alloys on advancing or retreating side.« less